Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 08:57
Tabular Output Report in Format: HTML
Building: HotelLarge
Environment: RUNPERIOD 1 ** Atlanta-Hartsfield Jackson Intl AP GA USA TMY3 WMO#=722190
Simulation Timestamp: 2023-10-16 08:58:01
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 15200.98 | 1339.85 | 1339.85 |
Net Site Energy | 15200.98 | 1339.85 | 1339.85 |
Total Source Energy | 35552.80 | 3133.71 | 3133.71 |
Net Source Energy | 35552.80 | 3133.71 | 3133.71 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 1.200 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil No 1 | 1.050 |
Fuel Oil No 2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 11345.29 |
Net Conditioned Building Area | 11345.29 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 1265.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 2593.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 1174.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 262.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1751.30 | 1788.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 679.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 1813.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 297.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 419.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 90.78 | 2989.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9857.19 |
Refrigeration | 74.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 9157.43 | 6043.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9857.19 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler | 0.00 | 1265.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 2593.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 1174.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 262.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 959.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 762.04 | 1198.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ReachInFreezer | 16.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ReachInRefrigerator | 13.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Laundry | 0.00 | 590.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Equipment | Transformer | 32.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ElevatorLift | 616.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ElevatorLightsFan | 30.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 1813.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 297.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 419.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Heater | 90.78 | 2989.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5742.51 | |
WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4114.69 | |
Refrigeration | General | 18.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
LowTempRefrigeration | 22.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
MedTempRefrigeration | 34.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | Unassigned | 0.00 | 1265.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | Unassigned | 2593.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GENERAL | 1174.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | Unassigned | 262.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | GENERAL | 1751.30 | 1788.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | Unassigned | 679.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Unassigned | 1813.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | Unassigned | 297.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | Unassigned | 419.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Unassigned | 90.78 | 2989.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9857.19 |
Refrigeration | Unassigned | 74.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 126.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 422.68 | 375.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.87 |
Other | 257.86 | 157.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 807.16 | 532.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.87 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 126.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 422.68 | 375.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.87 |
Other | 257.86 | 157.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 807.16 | 532.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.87 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 9157.433 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 9157.433 | 100.00 |
Total On-Site and Utility Electric Sources | 9157.433 | 100.00 |
Total Electricity End Uses | 9157.433 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | 0.00 |
Air to Air Heat Recovery for Cooling | 2615.00 | 50.41 |
Air to Air Heat Recovery for Heating | 2572.53 | 49.59 |
High-Temperature Geothermal* | 0.00 | 0.00 |
Solar Water Thermal | 0.00 | 0.00 |
Solar Air Thermal | 0.00 | 0.00 |
Total On-Site Thermal Sources | 5187.53 | 100.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 9857.19 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 9857.19 | 100.00 |
Total Water End Uses | 9857.19 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 17.50 |
Time Setpoint Not Met During Occupied Cooling | 10.17 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 6613.67 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Environment |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2012
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Environment |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME HOTELLARGE
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 3A
| Environment |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_GA_ATLANTA
| Environment |ZoneCoolingSummaryMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |ZoneHeatingSummaryMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |ZoneElectricSummaryMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |SpaceGainsMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |PeakSpaceGainsMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |SpaceGainComponentsAtCoolingPeakMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |ComfortReportSimple55Monthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |OccupantComfortDataSummaryMonthly
| BASEMENT PEOPLE | RETAIL_1_FLR_1 PEOPLE | RETAIL_2_FLR_1 PEOPLE | LAUNDRY_FLR_1 PEOPLE | CAFE_FLR_1 PEOPLE | LOBBY_FLR_1 PEOPLE | ROOM_1_FLR_3 PEOPLE | ROOM_2_FLR_3 PEOPLE | ROOM_3_MULT19_FLR_3 PEOPLE | ROOM_4_MULT19_FLR_3 PEOPLE | ROOM_5_FLR_3 PEOPLE | ROOM_6_FLR_3 PEOPLE | ROOM_1_FLR_6 PEOPLE | ROOM_2_FLR_6 PEOPLE | ROOM_3_MULT9_FLR_6 PEOPLE | BANQUET_FLR_6 PEOPLE | DINING_FLR_6 PEOPLE | KITCHEN_FLR_6 PEOPLE | STORAGE_FLR_1 PEOPLE | CORRIDOR_FLR_3 PEOPLE | CORRIDOR_FLR_6 PEOPLE | MECH_FLR_1 PEOPLE |ChillerReportMonthly
| COOLSYS1 CHILLER1 |BoilerReportMonthly
| HEATSYS1 BOILER |DXReportMonthly
| VAV WITH REHEAT COOLING COIL | FLR_3_DOAS COOLING COIL | ROOM_1_FLR_3 FAN COIL COOLING COIL | ROOM_2_FLR_3 FAN COIL COOLING COIL | ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | ROOM_5_FLR_3 FAN COIL COOLING COIL | ROOM_6_FLR_3 FAN COIL COOLING COIL | ROOM_1_FLR_6 FAN COIL COOLING COIL | ROOM_2_FLR_6 FAN COIL COOLING COIL | ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL |WindowReportMonthly
| RETAIL_1_FLR_1_WALL_SOUTH_WINDOW | CAFE_FLR_1_WALL_SOUTH_WINDOW | LOBBY_FLR_1_WALL_SOUTH_WINDOW | ROOM_1_FLR_3_WALL_SOUTH_WINDOW | ROOM_1_FLR_3_WALL_WEST_WINDOW | ROOM_2_FLR_3_WALL_NORTH_WINDOW | ROOM_2_FLR_3_WALL_WEST_WINDOW | ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW | ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW | ROOM_5_FLR_3_WALL_EAST_WINDOW | ROOM_5_FLR_3_WALL_SOUTH_WINDOW | ROOM_6_FLR_3_WALL_NORTH_WINDOW | ROOM_6_FLR_3_WALL_EAST_WINDOW | CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW | CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW | CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW | CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW | ROOM_1_FLR_6_WALL_SOUTH_WINDOW | ROOM_1_FLR_6_WALL_WEST_WINDOW | ROOM_2_FLR_6_WALL_NORTH_WINDOW | ROOM_2_FLR_6_WALL_WEST_WINDOW | ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW | BANQUET_FLR_6_WALL_NORTH_WINDOW | DINING_FLR_6_WALL_NORTH_WINDOW | KITCHEN_FLR_6_WALL_NORTH_WINDOW | KITCHEN_FLR_6_WALL_EAST_WINDOW | KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW | CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW | CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW | CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW |WindowEnergyReportMonthly
| RETAIL_1_FLR_1_WALL_SOUTH_WINDOW | CAFE_FLR_1_WALL_SOUTH_WINDOW | LOBBY_FLR_1_WALL_SOUTH_WINDOW | ROOM_1_FLR_3_WALL_SOUTH_WINDOW | ROOM_1_FLR_3_WALL_WEST_WINDOW | ROOM_2_FLR_3_WALL_NORTH_WINDOW | ROOM_2_FLR_3_WALL_WEST_WINDOW | ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW | ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW | ROOM_5_FLR_3_WALL_EAST_WINDOW | ROOM_5_FLR_3_WALL_SOUTH_WINDOW | ROOM_6_FLR_3_WALL_NORTH_WINDOW | ROOM_6_FLR_3_WALL_EAST_WINDOW | CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW | CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW | CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW | CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW | ROOM_1_FLR_6_WALL_SOUTH_WINDOW | ROOM_1_FLR_6_WALL_WEST_WINDOW | ROOM_2_FLR_6_WALL_NORTH_WINDOW | ROOM_2_FLR_6_WALL_WEST_WINDOW | ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW | BANQUET_FLR_6_WALL_NORTH_WINDOW | DINING_FLR_6_WALL_NORTH_WINDOW | KITCHEN_FLR_6_WALL_NORTH_WINDOW | KITCHEN_FLR_6_WALL_EAST_WINDOW | KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW | CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW | CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW | CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW |WindowZoneSummaryMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |WindowEnergyZoneSummaryMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| SWH BOOSTER E WATER HEATER | SWH LAUNDRY G WATER HEATER | SWHSYS1 WATER HEATER |DaylightingReportMonthly
| Environment |CoilReportMonthly
| VAV WITH REHEAT HEATING COIL | BASEMENT VAV BOX REHEAT COIL | RETAIL_1_FLR_1 VAV BOX REHEAT COIL | RETAIL_2_FLR_1 VAV BOX REHEAT COIL | MECH_FLR_1 VAV BOX REHEAT COIL | STORAGE_FLR_1 VAV BOX REHEAT COIL | LAUNDRY_FLR_1 VAV BOX REHEAT COIL | CAFE_FLR_1 VAV BOX REHEAT COIL | LOBBY_FLR_1 VAV BOX REHEAT COIL | CORRIDOR_FLR_3 VAV BOX REHEAT COIL | CORRIDOR_FLR_6 VAV BOX REHEAT COIL | BANQUET_FLR_6 VAV BOX REHEAT COIL | DINING_FLR_6 VAV BOX REHEAT COIL | KITCHEN_FLR_6 VAV BOX REHEAT COIL | FLR_3_DOAS HEATING COIL | ROOM_1_FLR_3 FAN COIL HEATING COIL | ROOM_2_FLR_3 FAN COIL HEATING COIL | ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL | ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL | ROOM_5_FLR_3 FAN COIL HEATING COIL | ROOM_6_FLR_3 FAN COIL HEATING COIL | ROOM_1_FLR_6 FAN COIL HEATING COIL | ROOM_2_FLR_6 FAN COIL HEATING COIL | ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL | VAV WITH REHEAT COOLING COIL | FLR_3_DOAS COOLING COIL | ROOM_1_FLR_3 FAN COIL COOLING COIL | ROOM_2_FLR_3 FAN COIL COOLING COIL | ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | ROOM_5_FLR_3 FAN COIL COOLING COIL | ROOM_6_FLR_3 FAN COIL COOLING COIL | ROOM_1_FLR_6 FAN COIL COOLING COIL | ROOM_2_FLR_6 FAN COIL COOLING COIL | ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL |PlantLoopDemandReportMonthly
| HEATSYS1 | COOLSYS1 | SWHSYS1 |FanReportMonthly
| FLR_3_DOAS FAN | VAV WITH REHEAT FAN | LAUNDRY_FLR_1 EXHAUST FAN | LOBBY_FLR_1 EXHAUST FAN | BANQUET_FLR_6 EXHAUST FAN | DINING_FLR_6 EXHAUST FAN | KITCHEN_FLR_6 EXHAUST FAN | ROOM_1_FLR_3 FAN COIL FAN COILFAN_FAN | ROOM_2_FLR_3 FAN COIL FAN COILFAN_FAN | ROOM_3_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN | ROOM_4_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN | ROOM_5_FLR_3 FAN COIL FAN COILFAN_FAN | ROOM_6_FLR_3 FAN COIL FAN COILFAN_FAN | ROOM_1_FLR_6 FAN COIL FAN COILFAN_FAN | ROOM_2_FLR_6 FAN COIL FAN COILFAN_FAN | ROOM_3_MULT9_FLR_6 FAN COIL FAN COILFAN_FAN |PumpReportMonthly
| HEATSYS1 PUMP | COOLSYS1 PUMP SECONDARY | COOLSYS1 PUMP | SWHSYS1 PUMP |CondLoopDemandReportMonthly
| HEATSYS1 | COOLSYS1 | SWHSYS1 |ZoneTemperatureOscillationReportMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |AirLoopSystemEnergyAndWaterUseMonthly
| VAV WITH REHEAT | FLR_3_DOAS |AirLoopSystemComponentLoadsMonthly
| VAV WITH REHEAT | FLR_3_DOAS |AirLoopSystemComponentEnergyUseMonthly
| VAV WITH REHEAT | FLR_3_DOAS |MechanicalVentilationLoadsMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |HeatEmissionsReportMonthly
| Environment |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
GeneralValue | |
Program Version and Build | EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 08:57 |
RunPeriod | RUNPERIOD 1 |
Weather File | Atlanta-Hartsfield Jackson Intl AP GA USA TMY3 WMO#=722190 |
Latitude [deg] | 33.63 |
Longitude [deg] | -84.4 |
Elevation [m] | 308.00 |
Time Zone | -5.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 4559.59 | 1873.43 | 406.47 | 1873.22 | 406.47 |
Above Ground Wall Area [m2] | 4025.82 | 1662.30 | 350.71 | 1662.10 | 350.71 |
Window Opening Area [m2] | 1213.79 | 432.95 | 85.85 | 609.15 | 85.85 |
Gross Window-Wall Ratio [%] | 26.62 | 23.11 | 21.12 | 32.52 | 21.12 |
Above Ground Window-Wall Ratio [%] | 30.15 | 26.05 | 24.48 | 36.65 | 24.48 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 4559.59 | 1873.43 | 406.47 | 1873.22 | 406.47 |
Above Ground Wall Area [m2] | 4025.82 | 1662.30 | 350.71 | 1662.10 | 350.71 |
Window Opening Area [m2] | 1213.79 | 432.95 | 85.85 | 609.15 | 85.85 |
Gross Window-Wall Ratio [%] | 26.62 | 23.11 | 21.12 | 32.52 | 21.12 |
Above Ground Window-Wall Ratio [%] | 30.15 | 26.05 | 24.48 | 36.65 | 24.48 |
Total | |
Gross Roof Area [m2] | 1978.84 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
BASEMENT | 1978.83 | Yes | Yes | 4826.41 | 1.00 | 0.00 | 533.77 | 0.00 | 0.00 | 8.7495 | 18.58 | 5.3800 |
RETAIL_1_FLR_1 | 67.07 | Yes | Yes | 265.76 | 1.00 | 68.84 | 0.00 | 23.26 | 23.26 | 13.0124 | 6.19 | 10.7600 |
RETAIL_2_FLR_1 | 77.67 | Yes | Yes | 307.76 | 1.00 | 26.57 | 0.00 | 0.00 | 0.00 | 13.0124 | 6.19 | 10.7600 |
MECH_FLR_1 | 164.24 | Yes | Yes | 650.80 | 1.00 | 62.80 | 0.00 | 0.00 | 0.00 | 10.0642 | 61.93 | 5.3800 |
STORAGE_FLR_1 | 94.76 | Yes | Yes | 375.47 | 1.00 | 36.23 | 0.00 | 0.00 | 0.00 | 7.3195 | 46.45 | 2.6900 |
LAUNDRY_FLR_1 | 78.04 | Yes | Yes | 309.22 | 1.00 | 85.75 | 0.00 | 0.00 | 0.00 | 5.4896 | 9.29 | 597.5300 |
CAFE_FLR_1 | 188.86 | Yes | Yes | 748.35 | 1.00 | 152.17 | 0.00 | 65.50 | 65.50 | 12.8090 | 1.33 | 5.3800 |
LOBBY_FLR_1 | 1308.19 | Yes | Yes | 5183.56 | 1.00 | 434.79 | 0.00 | 85.08 | 85.08 | 10.0642 | 3.10 | 8.0700 |
ROOM_1_FLR_3 | 39.02 | Yes | Yes | 118.94 | 4.00 | 39.95 | 0.00 | 13.18 | 13.18 | 10.0642 | 26.01 | 6.7500 |
ROOM_2_FLR_3 | 39.02 | Yes | Yes | 118.93 | 4.00 | 39.95 | 0.00 | 13.18 | 13.18 | 10.0642 | 26.01 | 6.7500 |
ROOM_3_MULT19_FLR_3 | 24.52 | Yes | Yes | 74.75 | 76.00 | 11.15 | 0.00 | 3.68 | 3.68 | 10.0642 | 16.35 | 10.5200 |
ROOM_4_MULT19_FLR_3 | 24.53 | Yes | Yes | 74.77 | 76.00 | 11.15 | 0.00 | 3.68 | 3.68 | 10.0642 | 16.35 | 10.5200 |
ROOM_5_FLR_3 | 39.02 | Yes | Yes | 118.94 | 4.00 | 39.95 | 0.00 | 13.18 | 13.18 | 10.0642 | 26.01 | 6.7500 |
ROOM_6_FLR_3 | 39.02 | Yes | Yes | 118.93 | 4.00 | 39.95 | 0.00 | 13.18 | 13.18 | 10.0642 | 26.01 | 6.7500 |
CORRIDOR_FLR_3 | 389.40 | Yes | Yes | 1186.91 | 4.00 | 48.31 | 0.00 | 15.94 | 15.94 | 3.6597 | 18.58 | 0.0000 |
ROOM_1_FLR_6 | 39.02 | Yes | Yes | 118.94 | 1.00 | 39.95 | 0.00 | 13.18 | 13.18 | 10.0642 | 26.01 | 6.7500 |
ROOM_2_FLR_6 | 39.02 | Yes | Yes | 118.93 | 1.00 | 39.95 | 0.00 | 13.18 | 13.18 | 10.0642 | 26.01 | 6.7500 |
ROOM_3_MULT9_FLR_6 | 24.53 | Yes | Yes | 74.77 | 9.00 | 20.44 | 0.00 | 6.74 | 6.74 | 10.0642 | 16.35 | 10.5200 |
BANQUET_FLR_6 | 331.66 | Yes | Yes | 1010.89 | 1.00 | 97.55 | 0.00 | 32.19 | 32.19 | 12.8090 | 1.33 | 67.8200 |
DINING_FLR_6 | 331.66 | Yes | Yes | 1010.89 | 1.00 | 97.55 | 0.00 | 32.19 | 32.19 | 12.8090 | 1.33 | 67.8200 |
KITCHEN_FLR_6 | 103.30 | Yes | Yes | 314.87 | 1.00 | 87.33 | 0.00 | 26.37 | 26.37 | 10.9792 | 4.65 | 2936.4163 |
CORRIDOR_FLR_6 | 412.12 | Yes | Yes | 1256.16 | 1.00 | 85.47 | 0.00 | 28.20 | 28.20 | 3.6597 | 18.58 | 0.0000 |
Total | 11345.29 | 35184.81 | 4025.82 | 533.77 | 1213.79 | 1213.79 | 8.9207 | 7.07 | 41.0885 | |||
Conditioned Total | 11345.29 | 35184.81 | 4025.82 | 533.77 | 1213.79 | 1213.79 | 8.9207 | 7.07 | 41.0885 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
BASEMENT | 1978.83 | Yes | Yes | 1.00 | BASEMENT | GENERAL | BASEMENT | 8.7495 | 18.58 | 5.3800 | |
RETAIL_1_FLR_1 | 67.07 | Yes | Yes | 1.00 | RETAIL_1_FLR_1 | GENERAL | RETAIL_1_FLR_1 | 13.0124 | 6.19 | 10.7600 | |
RETAIL_2_FLR_1 | 77.67 | Yes | Yes | 1.00 | RETAIL_2_FLR_1 | GENERAL | RETAIL_2_FLR_1 | 13.0124 | 6.19 | 10.7600 | |
MECH_FLR_1 | 164.24 | Yes | Yes | 1.00 | MECH_FLR_1 | GENERAL | MECH_FLR_1 | 10.0642 | 61.93 | 5.3800 | |
STORAGE_FLR_1 | 94.76 | Yes | Yes | 1.00 | STORAGE_FLR_1 | GENERAL | STORAGE_FLR_1 | 7.3195 | 46.45 | 2.6900 | |
LAUNDRY_FLR_1 | 78.04 | Yes | Yes | 1.00 | LAUNDRY_FLR_1 | GENERAL | LAUNDRY_FLR_1 | 5.4896 | 9.29 | 597.5300 | |
CAFE_FLR_1 | 188.86 | Yes | Yes | 1.00 | CAFE_FLR_1 | GENERAL | CAFE_FLR_1 | 12.8090 | 1.33 | 5.3800 | |
LOBBY_FLR_1 | 1308.19 | Yes | Yes | 1.00 | LOBBY_FLR_1 | GENERAL | LOBBY_FLR_1 | 10.0642 | 3.10 | 8.0700 | |
ROOM_1_FLR_3 | 39.02 | Yes | Yes | 4.00 | ROOM_1_FLR_3 | GENERAL | ROOM_1_FLR_3 | 10.0642 | 26.01 | 6.7500 | |
ROOM_2_FLR_3 | 39.02 | Yes | Yes | 4.00 | ROOM_2_FLR_3 | GENERAL | ROOM_2_FLR_3 | 10.0642 | 26.01 | 6.7500 | |
ROOM_3_MULT19_FLR_3 | 24.52 | Yes | Yes | 76.00 | ROOM_3_MULT19_FLR_3 | GENERAL | ROOM_3_MULT19_FLR_3 | 10.0642 | 16.35 | 10.5200 | |
ROOM_4_MULT19_FLR_3 | 24.53 | Yes | Yes | 76.00 | ROOM_4_MULT19_FLR_3 | GENERAL | ROOM_4_MULT19_FLR_3 | 10.0642 | 16.35 | 10.5200 | |
ROOM_5_FLR_3 | 39.02 | Yes | Yes | 4.00 | ROOM_5_FLR_3 | GENERAL | ROOM_5_FLR_3 | 10.0642 | 26.01 | 6.7500 | |
ROOM_6_FLR_3 | 39.02 | Yes | Yes | 4.00 | ROOM_6_FLR_3 | GENERAL | ROOM_6_FLR_3 | 10.0642 | 26.01 | 6.7500 | |
CORRIDOR_FLR_3 | 389.40 | Yes | Yes | 4.00 | CORRIDOR_FLR_3 | GENERAL | CORRIDOR_FLR_3 | 3.6597 | 18.58 | 0.0000 | |
ROOM_1_FLR_6 | 39.02 | Yes | Yes | 1.00 | ROOM_1_FLR_6 | GENERAL | ROOM_1_FLR_6 | 10.0642 | 26.01 | 6.7500 | |
ROOM_2_FLR_6 | 39.02 | Yes | Yes | 1.00 | ROOM_2_FLR_6 | GENERAL | ROOM_2_FLR_6 | 10.0642 | 26.01 | 6.7500 | |
ROOM_3_MULT9_FLR_6 | 24.53 | Yes | Yes | 9.00 | ROOM_3_MULT9_FLR_6 | GENERAL | ROOM_3_MULT9_FLR_6 | 10.0642 | 16.35 | 10.5200 | |
BANQUET_FLR_6 | 331.66 | Yes | Yes | 1.00 | BANQUET_FLR_6 | GENERAL | BANQUET_FLR_6 | 12.8090 | 1.33 | 67.8200 | |
DINING_FLR_6 | 331.66 | Yes | Yes | 1.00 | DINING_FLR_6 | GENERAL | DINING_FLR_6 | 12.8090 | 1.33 | 67.8200 | |
KITCHEN_FLR_6 | 103.30 | Yes | Yes | 1.00 | KITCHEN_FLR_6 | GENERAL | KITCHEN_FLR_6 | 10.9792 | 4.65 | 2936.4163 | |
CORRIDOR_FLR_6 | 412.12 | Yes | Yes | 1.00 | CORRIDOR_FLR_6 | GENERAL | CORRIDOR_FLR_6 | 3.6597 | 18.58 | 0.0000 | |
Total | 11345.29 | 8.9207 | 3.54 | 41.0885 | |||||||
Conditioned Total | 11345.29 | 8.9207 | 3.54 | 41.0885 | |||||||
Unconditioned Total | 0.00 | 0.0000 | 0.00 | 0.0000 | |||||||
Not Part of Total | 0.00 | 0.0000 | 0.00 | 0.0000 |
Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
GENERAL | 11345.29 | 11345.29 | 0.00 | 0.00 | 4.6908 | 8.82 | 37.2165 |
Total | 11345.29 | 11345.29 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
End UsesElectricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 02-AUG-19:40 | 07-JAN-17:10 | - | - | - | - | - | - | - | - | - | - | 02-JAN-21:10 |
Heating | 0.00 | 254973.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 258272.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 93091.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 16690.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 88971.67 | 89612.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 33025.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 69966.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 14658.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 17414.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 3782.30 | 248392.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 2933.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 598806.25 | 592977.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler | 0.00 | 254973.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 258272.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 93091.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 16690.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 58789.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 29240.64 | 74976.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ReachInFreezer | 515.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ReachInRefrigerator | 425.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Laundry | 0.00 | 14636.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Equipment | Transformer | 1900.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ElevatorLift | 30153.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ElevatorLightsFan | 972.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 69966.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 14658.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 17414.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Heater | 3782.30 | 248392.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 666.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
LowTempRefrigeration | 1158.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
MedTempRefrigeration | 1108.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 1371.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 8212.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 3718.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 831.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 5546.36 | 1939.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 2152.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 5744.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 941.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 1329.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 287.50 | 3240.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 236.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 29001.59 | 6551.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 120.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 723.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 327.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 73.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 488.87 | 170.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 189.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 506.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 82.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 117.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 25.34 | 285.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 20.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 2556.27 | 577.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 120.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 723.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 327.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 73.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 488.87 | 170.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 189.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 506.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 82.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 117.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 25.34 | 285.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 20.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 2556.27 | 577.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
AirTerminal:SingleDuct:VAV:ReheatDesign Size Maximum Air Flow Rate [m3/s] | Design Size Constant Minimum Air Flow Fraction | User-Specified Constant Minimum Air Flow Fraction | Design Size Minimum Air Flow Rate [m3/s] | Design Size Maximum Flow Fraction during Reheat [] | User-Specified Maximum Flow Fraction during Reheat [] | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | Design Size Maximum Reheat Water Flow Rate [m3/s] | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | |
BASEMENT VAV BOX COMPONENT | 2.51 | 0.601877 | 0.995000 | 2.49 | 1.00 | 0.500000 | 0.000633 | 0.000122 | 2.49 | 16.70 | 0.008000 |
RETAIL_1_FLR_1 VAV BOX COMPONENT | 0.337629 | 0.151375 | 0.995000 | 0.335940 | 0.995000 | 0.500000 | 0.002517 | 0.000043 | 0.335940 | 16.70 | 0.008000 |
RETAIL_2_FLR_1 VAV BOX COMPONENT | 0.250162 | 0.236582 | 0.995000 | 0.248911 | 0.995000 | 0.500000 | 0.001610 | 0.000020 | 0.248911 | 16.70 | 0.008000 |
MECH_FLR_1 VAV BOX COMPONENT | 0.263692 | 0.474619 | 0.995000 | 0.262374 | 1.00 | 0.500000 | 0.000803 | 0.000029 | 0.262374 | 16.70 | 0.008000 |
STORAGE_FLR_1 VAV BOX COMPONENT | 0.131544 | 0.548916 | 0.995000 | 0.130886 | 1.00 | 0.500000 | 0.000694 | 0.000016 | 0.130886 | 16.70 | 0.008000 |
LAUNDRY_FLR_1 VAV BOX COMPONENT | 3.40 | 0.069446 | 0.995000 | 3.38 | 0.995000 | 0.500000 | 0.021771 | 0.000173 | 3.38 | 16.70 | 0.008000 |
CAFE_FLR_1 VAV BOX COMPONENT | 1.46 | 0.098720 | 0.995000 | 1.45 | 0.995000 | 0.500000 | 0.003859 | 0.000135 | 1.45 | 16.70 | 0.008000 |
LOBBY_FLR_1 VAV BOX COMPONENT | 4.84 | 0.205840 | 0.995000 | 4.82 | 0.995000 | 0.500000 | 0.001851 | 0.000382 | 4.82 | 16.70 | 0.008000 |
CORRIDOR_FLR_3 VAV BOX COMPONENT | 1.16 | 1.00 | 0.995000 | 1.16 | 1.00 | 0.500000 | 0.000373 | 0.000148 | 1.16 | 16.70 | 0.008000 |
BANQUET_FLR_6 VAV BOX COMPONENT | 2.33 | 0.108649 | 0.995000 | 2.31 | 0.995000 | 0.500000 | 0.003507 | 0.000167 | 2.31 | 16.70 | 0.008000 |
DINING_FLR_6 VAV BOX COMPONENT | 2.44 | 0.103565 | 0.995000 | 2.43 | 0.995000 | 0.500000 | 0.003679 | 0.000173 | 2.43 | 16.70 | 0.008000 |
KITCHEN_FLR_6 VAV BOX COMPONENT | 2.36 | 0.800248 | 0.995000 | 2.35 | 0.995000 | 0.500000 | 0.011418 | 0.000124 | 2.35 | 16.70 | 0.008000 |
CORRIDOR_FLR_6 VAV BOX COMPONENT | 0.717927 | 0.437425 | 0.995000 | 0.714338 | 1.00 | 0.500000 | 0.000871 | 0.000099 | 0.714338 | 16.70 | 0.008000 |
Design Size Rated Capacity [W] | Design Size Maximum Water Flow Rate [m3/s] | Design Size U-Factor Times Area Value [W/K] | |
BASEMENT VAV BOX REHEAT COIL | 13901.20 | 0.000122 | 291.33 |
RETAIL_1_FLR_1 VAV BOX REHEAT COIL | 4933.80 | 0.000043 | 114.16 |
RETAIL_2_FLR_1 VAV BOX REHEAT COIL | 2338.12 | 0.000020 | 51.00 |
MECH_FLR_1 VAV BOX REHEAT COIL | 3349.56 | 0.000029 | 75.82 |
STORAGE_FLR_1 VAV BOX REHEAT COIL | 1871.32 | 0.000016 | 43.11 |
LAUNDRY_FLR_1 VAV BOX REHEAT COIL | 19827.68 | 0.000173 | 416.76 |
CAFE_FLR_1 VAV BOX REHEAT COIL | 15469.87 | 0.000135 | 342.11 |
LOBBY_FLR_1 VAV BOX REHEAT COIL | 43663.12 | 0.000382 | 949.07 |
ROOM_1_FLR_3 FAN COIL HEATING COIL | 7185.55 | 0.000063 | 205.36 |
ROOM_2_FLR_3 FAN COIL HEATING COIL | 7197.93 | 0.000063 | 205.72 |
ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL | 40940.92 | 0.000358 | 1170.08 |
ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL | 41190.56 | 0.000360 | 1177.21 |
ROOM_5_FLR_3 FAN COIL HEATING COIL | 7159.97 | 0.000063 | 204.63 |
ROOM_6_FLR_3 FAN COIL HEATING COIL | 7172.36 | 0.000063 | 204.99 |
CORRIDOR_FLR_3 VAV BOX REHEAT COIL | 16907.37 | 0.000148 | 390.88 |
ROOM_1_FLR_6 FAN COIL HEATING COIL | 2207.10 | 0.000019 | 63.08 |
ROOM_2_FLR_6 FAN COIL HEATING COIL | 2212.04 | 0.000019 | 63.22 |
ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL | 10571.41 | 0.000092 | 302.11 |
BANQUET_FLR_6 VAV BOX REHEAT COIL | 19074.64 | 0.000167 | 411.00 |
DINING_FLR_6 VAV BOX REHEAT COIL | 19787.81 | 0.000173 | 425.95 |
KITCHEN_FLR_6 VAV BOX REHEAT COIL | 14213.11 | 0.000124 | 299.33 |
CORRIDOR_FLR_6 VAV BOX REHEAT COIL | 11283.65 | 0.000099 | 264.49 |
VAV WITH REHEAT HEATING COIL | 177751.76 | 0.001555 | 3000.09 |
FLR_3_DOAS HEATING COIL | 16512.40 | 0.000144 | 278.70 |
User-Specified Maximum Flow Rate [m3/s] | |
LOBBY_FLR_1 EXHAUST FAN | 0.000000 |
BANQUET_FLR_6 EXHAUST FAN | 0.000000 |
DINING_FLR_6 EXHAUST FAN | 0.000000 |
Design Size Maximum Air Flow Rate [m3/s] | |
ROOM_1_FLR_3 DIRECT AIR | 0.061735 |
ROOM_2_FLR_3 DIRECT AIR | 0.061728 |
ROOM_3_MULT19_FLR_3 DIRECT AIR | 0.837072 |
ROOM_4_MULT19_FLR_3 DIRECT AIR | 0.837300 |
ROOM_5_FLR_3 DIRECT AIR | 0.061735 |
ROOM_6_FLR_3 DIRECT AIR | 0.061728 |
ROOM_1_FLR_6 DIRECT AIR | 0.015434 |
ROOM_2_FLR_6 DIRECT AIR | 0.015432 |
ROOM_3_MULT9_FLR_6 DIRECT AIR | 0.099154 |
Design Size Maximum Supply Air Flow Rate [m3/s] | Design Size Maximum Hot Water Flow [m3/s] | Design Size Maximum Cold Water Flow [m3/s] | |
ROOM_1_FLR_3 FAN COIL | 1.08 | 0.000063 | 0.000476 |
ROOM_2_FLR_3 FAN COIL | 1.07 | 0.000063 | 0.000471 |
ROOM_3_MULT19_FLR_3 FAN COIL | 6.68 | 0.000358 | 0.002878 |
ROOM_4_MULT19_FLR_3 FAN COIL | 7.02 | 0.000360 | 0.003168 |
ROOM_5_FLR_3 FAN COIL | 0.972144 | 0.000063 | 0.000432 |
ROOM_6_FLR_3 FAN COIL | 0.963247 | 0.000063 | 0.000428 |
ROOM_1_FLR_6 FAN COIL | 0.289510 | 0.000019 | 0.000127 |
ROOM_2_FLR_6 FAN COIL | 0.285908 | 0.000019 | 0.000126 |
ROOM_3_MULT9_FLR_6 FAN COIL | 1.33 | 0.000092 | 0.000591 |
Design Size Maximum Flow Rate [m3/s] | |
ROOM_1_FLR_3 FAN COIL FAN COILFAN_FAN | 1.08 |
ROOM_2_FLR_3 FAN COIL FAN COILFAN_FAN | 1.07 |
ROOM_3_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN | 6.68 |
ROOM_4_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN | 7.02 |
ROOM_5_FLR_3 FAN COIL FAN COILFAN_FAN | 0.972144 |
ROOM_6_FLR_3 FAN COIL FAN COILFAN_FAN | 0.963247 |
ROOM_1_FLR_6 FAN COIL FAN COILFAN_FAN | 0.289510 |
ROOM_2_FLR_6 FAN COIL FAN COILFAN_FAN | 0.285908 |
ROOM_3_MULT9_FLR_6 FAN COIL FAN COILFAN_FAN | 1.33 |
Design Size Design Inlet Air Temperature [C] | Design Size Design Inlet Water Temperature [C] | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | Design Size Design Outlet Air Temperature [C] | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | Design Size Design Water Flow Rate [m3/s] | Design Size Design Air Flow Rate [m3/s] | Design Size Design Coil Load [W] | |
ROOM_1_FLR_3 FAN COIL COOLING COIL | 22.54 | 6.70 | 0.008773 | 12.80 | 0.008500 | 0.000476 | 1.08 | |
ROOM_2_FLR_3 FAN COIL COOLING COIL | 22.54 | 6.70 | 0.008776 | 12.80 | 0.008500 | 0.000471 | 1.07 | |
ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | 22.54 | 6.70 | 0.008675 | 12.80 | 0.008500 | 0.002878 | 6.68 | |
ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | 22.54 | 6.70 | 0.008869 | 12.80 | 0.008500 | 0.003168 | 7.02 | |
ROOM_5_FLR_3 FAN COIL COOLING COIL | 22.54 | 6.70 | 0.008803 | 12.80 | 0.008500 | 0.000432 | 0.972144 | |
ROOM_6_FLR_3 FAN COIL COOLING COIL | 22.54 | 6.70 | 0.008806 | 12.80 | 0.008500 | 0.000428 | 0.963247 | |
ROOM_1_FLR_6 FAN COIL COOLING COIL | 22.54 | 6.70 | 0.008755 | 12.80 | 0.008500 | 0.000127 | 0.289510 | |
ROOM_2_FLR_6 FAN COIL COOLING COIL | 22.54 | 6.70 | 0.008758 | 12.80 | 0.008500 | 0.000126 | 0.285908 | |
ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL | 22.54 | 6.70 | 0.008817 | 12.80 | 0.008500 | 0.000591 | 1.33 | |
VAV WITH REHEAT COOLING COIL | 34.40 | 6.70 | 0.014473 | 10.93 | 0.008500 | 0.035964 | 22.08 | 1006896.45 |
FLR_3_DOAS COOLING COIL | 34.40 | 6.70 | 0.014473 | 11.91 | 0.008500 | 0.003256 | 2.05 | 91161.11 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
VAV WITH REHEAT | 22.08 | 22.08 | 22.19 | 22.08 | 22.08 | 22.08 | 0.300000 | 1.00 | 22.08 |
FLR_3_DOAS | 2.05 | 2.05 | 2.05 | 2.05 | 2.05 | 2.05 | 0.300000 | 1.00 | 2.05 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
VAV WITH REHEAT_OA_CONTROLLER | 22.08 | 22.08 |
FLR_3_DOAS_OA_CONTROLLER | 2.05 | 2.05 |
Design Size Nominal Supply Air Flow Rate [m3/s] | |
VAV WITH REHEAT OA HEAT RECOVERY | 22.08 |
FLR_3_DOAS OA HEAT RECOVERY | 2.05 |
Design Size Maximum Flow Rate [m3/s] | |
VAV WITH REHEAT FAN | 22.08 |
Maximum Actuated Flow [m3/s] | Controller Convergence Tolerance | |
VAV WITH REHEAT_COOLC_CONTROLLER | 0.035964 | 0.000013 |
VAV WITH REHEAT_HEATC_CONTROLLER | 0.001555 | |
FLR_3_DOAS_COOLC_CONTROLLER | 0.003256 | 0.000146 |
FLR_3_DOAS_HEATC_CONTROLLER | 0.000144 |
User-Specified Maximum Flow Rate [m3/s] | |
FLR_3_DOAS FAN | 2.05 |
Design Flow Rate [m3/s] | Design Power Consumption [W] | Design Minimum Flow Rate [m3/s] | |
COOLSYS1 PUMP SECONDARY | 0.047916 | 9873.74 | |
HEATSYS1 PUMP | 0.004433 | 1335.04 | 0.000000 |
Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
HEATSYS1 | 0.004433 | 0.531964 |
COOLSYS1 | 0.047916 | 5.75 |
SWHSYS1 | 0.000375 | 0.045004 |
Design Size Nominal Capacity [W] | User-Specified Nominal Capacity [W] | Design Size Design Water Flow Rate [m3/s] | |
HEATSYS1 BOILER | 506723.24 | 506723.24 | 0.004433 |
Design Flow Rate [m3/s] | Design Power Consumption [W] | |
COOLSYS1 PUMP | 0.047916 | 6835.92 |
SWHSYS1 PUMP | 0.000375 | 47.91 |
Design Size Reference Chilled Water Flow Rate [m3/s] | Design Size Reference Capacity [W] | User-Specified Reference Capacity [W] | Design Size Reference Condenser Fluid Flow Rate [m3/s] | |
COOLSYS1 CHILLER1 | 0.047916 | 1341523.97 | 1342132.77 | 153.00 |
Use Side Design Flow Rate [m3/s] | |
SWHSYS1 WATER HEATER | 0.000375 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesPossible Shadow Receivers | |
RETAIL_1_FLR_1_CEILING | ROOM_1_FLR_3_WALL_SOUTH | ROOM_3_MULT19_FLR_3_WALL_SOUTH | ROOM_5_FLR_3_WALL_SOUTH | CORRIDOR_FLR_3_WALL_1_SOUTH | CORRIDOR_FLR_3_WALL_2_SOUTH | ROOM_1_FLR_6_WALL_SOUTH | ROOM_3_MULT9_FLR_6_WALL_SOUTH | KITCHEN_FLR_6_WALL_1_SOUTH | CORRIDOR_FLR_6_WALL_2_SOUTH | |
CAFE_FLR_1_CEILING | ROOM_1_FLR_3_WALL_SOUTH | ROOM_3_MULT19_FLR_3_WALL_SOUTH | ROOM_5_FLR_3_WALL_SOUTH | CORRIDOR_FLR_3_WALL_1_SOUTH | CORRIDOR_FLR_3_WALL_2_SOUTH | ROOM_1_FLR_6_WALL_SOUTH | ROOM_3_MULT9_FLR_6_WALL_SOUTH | KITCHEN_FLR_6_WALL_1_SOUTH | CORRIDOR_FLR_6_WALL_2_SOUTH | |
LOBBY_FLR_1_CEILING_2 | ROOM_1_FLR_3_WALL_SOUTH | ROOM_3_MULT19_FLR_3_WALL_SOUTH | ROOM_5_FLR_3_WALL_SOUTH | CORRIDOR_FLR_3_WALL_1_SOUTH | CORRIDOR_FLR_3_WALL_2_SOUTH | ROOM_1_FLR_6_WALL_SOUTH | ROOM_3_MULT9_FLR_6_WALL_SOUTH | KITCHEN_FLR_6_WALL_1_SOUTH | CORRIDOR_FLR_6_WALL_2_SOUTH | |
Possible Shadow Receivers | |
RETAIL_1_FLR_1_WALL_SOUTH | RETAIL_1_FLR_1_WALL_SOUTH_WINDOW | |
RETAIL_2_FLR_1_WALL_WEST | RETAIL_2_FLR_1_WALL_WEST_DOOR | |
STORAGE_FLR_1_WALL_NORTH | STORAGE_FLR_1_WALL_NORTH_ROLLDOOR | |
LAUNDRY_FLR_1_WALL_EAST | LAUNDRY_FLR_1_WALL_EAST_DOOR | |
CAFE_FLR_1_WALL_EAST | CAFE_FLR_1_WALL_EAST_DOOR | |
CAFE_FLR_1_WALL_SOUTH | CAFE_FLR_1_WALL_SOUTH_WINDOW | |
LOBBY_FLR_1_WALL_1_NORTH | LOBBY_FLR_1_WALL_1_NORTH_DOOR1 | LOBBY_FLR_1_WALL_1_NORTH_DOOR2 | |
LOBBY_FLR_1_WALL_1_SOUTH | LOBBY_FLR_1_WALL_SOUTH_WINDOW | |
ROOM_1_FLR_3_WALL_SOUTH | ROOM_1_FLR_3_WALL_SOUTH_WINDOW | |
ROOM_1_FLR_3_WALL_WEST | ROOM_1_FLR_3_WALL_WEST_WINDOW | |
ROOM_2_FLR_3_WALL_NORTH | ROOM_2_FLR_3_WALL_NORTH_WINDOW | |
ROOM_2_FLR_3_WALL_WEST | ROOM_2_FLR_3_WALL_WEST_WINDOW | |
ROOM_3_MULT19_FLR_3_WALL_SOUTH | ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW | |
ROOM_4_MULT19_FLR_3_WALL_NORTH | ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW | |
ROOM_5_FLR_3_WALL_EAST | ROOM_5_FLR_3_WALL_EAST_WINDOW | |
ROOM_5_FLR_3_WALL_SOUTH | ROOM_5_FLR_3_WALL_SOUTH_WINDOW | |
ROOM_6_FLR_3_WALL_NORTH | ROOM_6_FLR_3_WALL_NORTH_WINDOW | |
ROOM_6_FLR_3_WALL_EAST | ROOM_6_FLR_3_WALL_EAST_WINDOW | |
CORRIDOR_FLR_3_WALL_1_NORTH | CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW | |
CORRIDOR_FLR_3_WALL_2_NORTH | CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW | |
CORRIDOR_FLR_3_WALL_1_SOUTH | CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW | |
CORRIDOR_FLR_3_WALL_2_SOUTH | CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW | |
ROOM_1_FLR_6_WALL_SOUTH | ROOM_1_FLR_6_WALL_SOUTH_WINDOW | |
ROOM_1_FLR_6_WALL_WEST | ROOM_1_FLR_6_WALL_WEST_WINDOW | |
ROOM_2_FLR_6_WALL_NORTH | ROOM_2_FLR_6_WALL_NORTH_WINDOW | |
ROOM_2_FLR_6_WALL_WEST | ROOM_2_FLR_6_WALL_WEST_WINDOW | |
ROOM_3_MULT9_FLR_6_WALL_SOUTH | ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW | |
BANQUET_FLR_6_WALL_NORTH | BANQUET_FLR_6_WALL_NORTH_WINDOW | |
DINING_FLR_6_WALL_NORTH | DINING_FLR_6_WALL_NORTH_WINDOW | |
KITCHEN_FLR_6_WALL_NORTH | KITCHEN_FLR_6_WALL_NORTH_WINDOW | |
KITCHEN_FLR_6_WALL_EAST | KITCHEN_FLR_6_WALL_EAST_WINDOW | |
KITCHEN_FLR_6_WALL_1_SOUTH | KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW | |
CORRIDOR_FLR_6_WALL_1_NORTH | CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW | |
CORRIDOR_FLR_6_WALL_2_NORTH | CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW | |
CORRIDOR_FLR_6_WALL_2_SOUTH | CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
VersionVersion ID | |
1 | 22.1 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 11.90 | 7.70 | 4.00 | 7.90 | 13.80 | 17.20 | 20.80 | 24.80 | 26.10 | 26.50 | 22.50 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | Atlanta-Hartsfield Jackson Intl AP GA USA TMY3 WMO#=722190 | 33.63 | -84.43 | -5.00 | 308.00 | 97679 | 1.1610 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 16.60 | 22.50 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | HotelLarge | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | DOE-2 |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 22 | 235 | 36 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | BASEMENT | 0.0 | 0.00 | 0.00 | 0.00 | 41.45 | 11.51 | -1.22 | 1 | 1 | 1 | 0.00 | 86.56 | 0.00 | 22.86 | -2.44 | 0.00 | 2.44 | 4826.41 | TARP | DOE-2 | 1978.83 | 0.00 | 0.00 | 0.00 | 13 | 0 | 0 | Yes |
2 | RETAIL_1_FLR_1 | 0.0 | 0.00 | 0.00 | 0.00 | 5.79 | 2.90 | 1.98 | 1 | 1 | 1 | 0.00 | 11.58 | 0.00 | 5.79 | 0.00 | 3.96 | 3.96 | 265.76 | TARP | DOE-2 | 67.07 | 68.84 | 45.58 | 23.26 | 6 | 1 | 0 | Yes |
3 | RETAIL_2_FLR_1 | 0.0 | 0.00 | 0.00 | 0.00 | 5.79 | 9.14 | 1.98 | 1 | 1 | 1 | 0.00 | 11.58 | 5.79 | 12.50 | 0.00 | 3.96 | 3.96 | 307.76 | TARP | DOE-2 | 77.67 | 26.57 | 24.62 | 0.00 | 6 | 1 | 0 | Yes |
4 | MECH_FLR_1 | 0.0 | 0.00 | 0.00 | 0.00 | 61.87 | 17.68 | 1.98 | 1 | 1 | 1 | 53.95 | 69.80 | 12.50 | 22.86 | 0.00 | 3.96 | 3.96 | 650.80 | TARP | DOE-2 | 164.24 | 62.80 | 62.80 | 0.00 | 6 | 0 | 0 | Yes |
5 | STORAGE_FLR_1 | 0.0 | 0.00 | 0.00 | 0.00 | 74.37 | 17.68 | 1.98 | 1 | 1 | 1 | 69.80 | 78.94 | 12.50 | 22.86 | 0.00 | 3.96 | 3.96 | 375.47 | TARP | DOE-2 | 94.76 | 36.23 | 28.80 | 0.00 | 6 | 1 | 0 | Yes |
6 | LAUNDRY_FLR_1 | 0.0 | 0.00 | 0.00 | 0.00 | 84.28 | 14.33 | 1.98 | 1 | 1 | 1 | 81.99 | 86.56 | 5.79 | 22.86 | 0.00 | 3.96 | 3.96 | 309.22 | TARP | DOE-2 | 78.04 | 85.75 | 83.80 | 0.00 | 6 | 1 | 0 | Yes |
7 | CAFE_FLR_1 | 0.0 | 0.00 | 0.00 | 0.00 | 70.26 | 2.90 | 1.98 | 1 | 1 | 1 | 53.95 | 86.56 | 0.00 | 5.79 | 0.00 | 3.96 | 3.96 | 748.35 | TARP | DOE-2 | 188.86 | 152.17 | 84.72 | 65.50 | 7 | 2 | 0 | Yes |
8 | LOBBY_FLR_1 | 0.0 | 0.00 | 0.00 | 0.00 | 38.29 | 12.45 | 1.98 | 1 | 1 | 1 | 0.00 | 81.99 | 0.00 | 22.86 | 0.00 | 3.96 | 3.96 | 5183.56 | TARP | DOE-2 | 1308.19 | 434.79 | 345.80 | 85.08 | 18 | 3 | 0 | Yes |
9 | ROOM_1_FLR_3 | 0.0 | 0.00 | 0.00 | 0.00 | 2.29 | 10.06 | 8.53 | 1 | 4 | 1 | 0.00 | 4.57 | 5.79 | 14.33 | 7.01 | 10.06 | 3.05 | 118.94 | TARP | DOE-2 | 39.02 | 39.95 | 26.77 | 13.18 | 6 | 2 | 0 | Yes |
10 | ROOM_2_FLR_3 | 0.0 | 0.00 | 0.00 | 0.00 | 2.29 | 18.59 | 8.53 | 1 | 4 | 1 | 0.00 | 4.57 | 14.33 | 22.86 | 7.01 | 10.06 | 3.05 | 118.93 | TARP | DOE-2 | 39.02 | 39.95 | 26.76 | 13.18 | 6 | 2 | 0 | Yes |
11 | ROOM_3_MULT19_FLR_3 | 0.0 | 0.00 | 0.00 | 0.00 | 8.53 | 9.14 | 8.53 | 1 | 76 | 1 | 6.71 | 10.36 | 5.79 | 12.50 | 7.01 | 10.06 | 3.05 | 74.75 | TARP | DOE-2 | 24.52 | 11.15 | 7.47 | 3.68 | 6 | 1 | 0 | Yes |
12 | ROOM_4_MULT19_FLR_3 | 0.0 | 0.00 | 0.00 | 0.00 | 12.19 | 19.51 | 8.53 | 1 | 76 | 1 | 10.36 | 14.02 | 16.15 | 22.86 | 7.01 | 10.06 | 3.05 | 74.77 | TARP | DOE-2 | 24.53 | 11.15 | 7.47 | 3.68 | 6 | 1 | 0 | Yes |
13 | ROOM_5_FLR_3 | 0.0 | 0.00 | 0.00 | 0.00 | 84.28 | 10.06 | 8.53 | 1 | 4 | 1 | 81.99 | 86.56 | 5.79 | 14.33 | 7.01 | 10.06 | 3.05 | 118.94 | TARP | DOE-2 | 39.02 | 39.95 | 26.77 | 13.18 | 6 | 2 | 0 | Yes |
14 | ROOM_6_FLR_3 | 0.0 | 0.00 | 0.00 | 0.00 | 84.28 | 18.59 | 8.53 | 1 | 4 | 1 | 81.99 | 86.56 | 14.33 | 22.86 | 7.01 | 10.06 | 3.05 | 118.93 | TARP | DOE-2 | 39.02 | 39.95 | 26.76 | 13.18 | 6 | 2 | 0 | Yes |
15 | CORRIDOR_FLR_3 | 0.0 | 0.00 | 0.00 | 0.00 | 43.28 | 14.33 | 8.53 | 1 | 4 | 1 | 4.57 | 81.99 | 5.79 | 22.86 | 7.01 | 10.06 | 3.05 | 1186.91 | TARP | DOE-2 | 389.40 | 48.31 | 32.37 | 15.94 | 20 | 4 | 0 | Yes |
16 | ROOM_1_FLR_6 | 0.0 | 0.00 | 0.00 | 0.00 | 2.29 | 10.06 | 17.68 | 1 | 1 | 1 | 0.00 | 4.57 | 5.79 | 14.33 | 16.15 | 19.20 | 3.05 | 118.94 | TARP | DOE-2 | 39.02 | 39.95 | 26.77 | 13.18 | 6 | 2 | 0 | Yes |
17 | ROOM_2_FLR_6 | 0.0 | 0.00 | 0.00 | 0.00 | 2.29 | 18.59 | 17.68 | 1 | 1 | 1 | 0.00 | 4.57 | 14.33 | 22.86 | 16.15 | 19.20 | 3.05 | 118.93 | TARP | DOE-2 | 39.02 | 39.95 | 26.76 | 13.18 | 6 | 2 | 0 | Yes |
18 | ROOM_3_MULT9_FLR_6 | 0.0 | 0.00 | 0.00 | 0.00 | 7.93 | 7.62 | 17.68 | 1 | 9 | 1 | 4.57 | 11.28 | 5.79 | 9.45 | 16.15 | 19.20 | 3.05 | 74.77 | TARP | DOE-2 | 24.53 | 20.44 | 13.70 | 6.74 | 6 | 1 | 0 | Yes |
19 | BANQUET_FLR_6 | 0.0 | 0.00 | 0.00 | 0.00 | 26.37 | 17.68 | 17.68 | 1 | 1 | 1 | 10.36 | 42.37 | 12.50 | 22.86 | 16.15 | 19.20 | 3.05 | 1010.89 | TARP | DOE-2 | 331.66 | 97.55 | 65.36 | 32.19 | 6 | 1 | 0 | Yes |
20 | DINING_FLR_6 | 0.0 | 0.00 | 0.00 | 0.00 | 63.55 | 17.68 | 17.68 | 1 | 1 | 1 | 47.55 | 79.55 | 12.50 | 22.86 | 16.15 | 19.20 | 3.05 | 1010.89 | TARP | DOE-2 | 331.66 | 97.55 | 65.36 | 32.19 | 6 | 1 | 0 | Yes |
21 | KITCHEN_FLR_6 | 0.0 | 0.00 | 0.00 | 0.00 | 82.99 | 14.11 | 17.68 | 1 | 1 | 1 | 79.55 | 86.56 | 5.79 | 22.86 | 16.15 | 19.20 | 3.05 | 314.87 | TARP | DOE-2 | 103.30 | 87.33 | 60.96 | 26.37 | 8 | 3 | 0 | Yes |
22 | CORRIDOR_FLR_6 | 0.0 | 0.00 | 0.00 | 0.00 | 41.51 | 13.35 | 17.68 | 1 | 1 | 1 | 4.57 | 81.99 | 5.79 | 22.86 | 16.15 | 19.20 | 3.05 | 1256.16 | TARP | DOE-2 | 412.12 | 85.47 | 57.27 | 28.20 | 15 | 3 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | BASEMENT | 1978.83 | 106.5 | 18.581 | 5.382E-002 | 8.749 | 5.380 | 0.000 | 0.000 | 0.000 | 0.000 | 14.129 | No |
2 | RETAIL_1_FLR_1 | 67.07 | 10.8 | 6.194 | 0.161 | 13.012 | 10.760 | 0.000 | 0.000 | 0.000 | 0.000 | 23.772 | No |
3 | RETAIL_2_FLR_1 | 77.67 | 12.5 | 6.194 | 0.161 | 13.012 | 10.760 | 0.000 | 0.000 | 0.000 | 0.000 | 23.772 | No |
4 | MECH_FLR_1 | 164.24 | 2.7 | 61.932 | 1.615E-002 | 10.064 | 5.380 | 0.000 | 0.000 | 0.000 | 0.000 | 15.444 | No |
5 | STORAGE_FLR_1 | 94.76 | 2.0 | 46.451 | 2.153E-002 | 7.319 | 2.690 | 0.000 | 0.000 | 0.000 | 0.000 | 10.009 | No |
6 | LAUNDRY_FLR_1 | 78.04 | 8.4 | 9.290 | 0.108 | 5.490 | 61.680 | 535.850 | 0.000 | 0.000 | 0.000 | 603.020 | No |
7 | CAFE_FLR_1 | 188.86 | 142.3 | 1.327 | 0.753 | 12.809 | 5.380 | 0.000 | 0.000 | 0.000 | 0.000 | 18.189 | No |
8 | LOBBY_FLR_1 | 1308.19 | 422.4 | 3.097 | 0.323 | 10.064 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 18.134 | No |
9 | ROOM_1_FLR_3 | 39.02 | 1.5 | 26.015 | 3.844E-002 | 10.064 | 6.750 | 0.000 | 0.000 | 0.000 | 0.000 | 16.814 | No |
10 | ROOM_2_FLR_3 | 39.02 | 1.5 | 26.012 | 3.844E-002 | 10.064 | 6.750 | 0.000 | 0.000 | 0.000 | 0.000 | 16.814 | No |
11 | ROOM_3_MULT19_FLR_3 | 24.52 | 1.5 | 16.349 | 6.116E-002 | 10.064 | 10.520 | 0.000 | 0.000 | 0.000 | 0.000 | 20.584 | No |
12 | ROOM_4_MULT19_FLR_3 | 24.53 | 1.5 | 16.354 | 6.115E-002 | 10.064 | 10.520 | 0.000 | 0.000 | 0.000 | 0.000 | 20.584 | No |
13 | ROOM_5_FLR_3 | 39.02 | 1.5 | 26.015 | 3.844E-002 | 10.064 | 6.750 | 0.000 | 0.000 | 0.000 | 0.000 | 16.814 | No |
14 | ROOM_6_FLR_3 | 39.02 | 1.5 | 26.012 | 3.844E-002 | 10.064 | 6.750 | 0.000 | 0.000 | 0.000 | 0.000 | 16.814 | No |
15 | CORRIDOR_FLR_3 | 389.40 | 21.0 | 18.581 | 5.382E-002 | 3.660 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 3.660 | No |
16 | ROOM_1_FLR_6 | 39.02 | 1.5 | 26.015 | 3.844E-002 | 10.064 | 6.750 | 0.000 | 0.000 | 0.000 | 0.000 | 16.814 | No |
17 | ROOM_2_FLR_6 | 39.02 | 1.5 | 26.012 | 3.844E-002 | 10.064 | 6.750 | 0.000 | 0.000 | 0.000 | 0.000 | 16.814 | No |
18 | ROOM_3_MULT9_FLR_6 | 24.53 | 1.5 | 16.354 | 6.115E-002 | 10.064 | 10.520 | 0.000 | 0.000 | 0.000 | 0.000 | 20.584 | No |
19 | BANQUET_FLR_6 | 331.66 | 249.9 | 1.327 | 0.753 | 12.809 | 67.820 | 0.000 | 0.000 | 0.000 | 0.000 | 80.629 | No |
20 | DINING_FLR_6 | 331.66 | 249.9 | 1.327 | 0.753 | 12.809 | 67.820 | 0.000 | 0.000 | 0.000 | 0.000 | 80.629 | No |
21 | KITCHEN_FLR_6 | 103.30 | 22.2 | 4.645 | 0.215 | 10.979 | 517.156 | 2419.260 | 0.000 | 0.000 | 0.000 | 2947.395 | No |
22 | CORRIDOR_FLR_6 | 412.12 | 22.2 | 18.581 | 5.382E-002 | 3.660 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 3.660 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | Cooling Effect Calculation | Ankle Draft Calculation | |
1 | BASEMENT PEOPLE | BLDG_OCC_SCH | BASEMENT | 1978.83 | 106.5 | 106.5 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 106 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
2 | RETAIL_1_FLR_1 PEOPLE | BLDG_OCC_SCH | RETAIL_1_FLR_1 | 67.07 | 10.8 | 10.8 | 0.161 | 6.194 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
3 | RETAIL_2_FLR_1 PEOPLE | BLDG_OCC_SCH | RETAIL_2_FLR_1 | 77.67 | 12.5 | 12.5 | 0.161 | 6.194 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 13 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
4 | LAUNDRY_FLR_1 PEOPLE | BLDG_OCC_SCH | LAUNDRY_FLR_1 | 78.04 | 8.4 | 8.4 | 0.108 | 9.290 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 8 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
5 | CAFE_FLR_1 PEOPLE | BLDG_OCC_SCH | CAFE_FLR_1 | 188.86 | 142.3 | 142.3 | 0.753 | 1.327 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 142 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
6 | LOBBY_FLR_1 PEOPLE | BLDG_OCC_SCH | LOBBY_FLR_1 | 1308.19 | 422.4 | 422.4 | 0.323 | 3.097 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 422 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
7 | ROOM_1_FLR_3 PEOPLE | GUESTROOM_OCC_SCH | ROOM_1_FLR_3 | 39.02 | 1.5 | 1.5 | 3.844E-002 | 26.015 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
8 | ROOM_2_FLR_3 PEOPLE | GUESTROOM_OCC_SCH | ROOM_2_FLR_3 | 39.02 | 1.5 | 1.5 | 3.844E-002 | 26.012 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
9 | ROOM_3_MULT19_FLR_3 PEOPLE | ALWAYS_OFF | ROOM_3_MULT19_FLR_3 | 24.52 | 1.5 | 1.5 | 6.116E-002 | 16.349 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
10 | ROOM_4_MULT19_FLR_3 PEOPLE | GUESTROOM_OCC_SCH | ROOM_4_MULT19_FLR_3 | 24.53 | 1.5 | 1.5 | 6.115E-002 | 16.354 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
11 | ROOM_5_FLR_3 PEOPLE | GUESTROOM_OCC_SCH | ROOM_5_FLR_3 | 39.02 | 1.5 | 1.5 | 3.844E-002 | 26.015 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
12 | ROOM_6_FLR_3 PEOPLE | GUESTROOM_OCC_SCH | ROOM_6_FLR_3 | 39.02 | 1.5 | 1.5 | 3.844E-002 | 26.012 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
13 | ROOM_1_FLR_6 PEOPLE | GUESTROOM_OCC_SCH | ROOM_1_FLR_6 | 39.02 | 1.5 | 1.5 | 3.844E-002 | 26.015 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
14 | ROOM_2_FLR_6 PEOPLE | GUESTROOM_OCC_SCH | ROOM_2_FLR_6 | 39.02 | 1.5 | 1.5 | 3.844E-002 | 26.012 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
15 | ROOM_3_MULT9_FLR_6 PEOPLE | GUESTROOM_OCC_SCH | ROOM_3_MULT9_FLR_6 | 24.53 | 1.5 | 1.5 | 6.115E-002 | 16.354 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
16 | BANQUET_FLR_6 PEOPLE | BLDG_OCC_SCH | BANQUET_FLR_6 | 331.66 | 249.9 | 249.9 | 0.753 | 1.327 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 250 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
17 | DINING_FLR_6 PEOPLE | BLDG_OCC_SCH | DINING_FLR_6 | 331.66 | 249.9 | 249.9 | 0.753 | 1.327 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 250 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
18 | KITCHEN_FLR_6 PEOPLE | BLDG_OCC_SCH | KITCHEN_FLR_6 | 103.30 | 22.2 | 22.2 | 0.215 | 4.645 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 22 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
19 | STORAGE_FLR_1 PEOPLE | BLDG_OCC_SCH | STORAGE_FLR_1 | 94.76 | 2.0 | 2.0 | 2.153E-002 | 46.451 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
20 | CORRIDOR_FLR_3 PEOPLE | BLDG_OCC_SCH | CORRIDOR_FLR_3 | 389.40 | 21.0 | 21.0 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 21 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
21 | CORRIDOR_FLR_6 PEOPLE | BLDG_OCC_SCH | CORRIDOR_FLR_6 | 412.12 | 22.2 | 22.2 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 22 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
22 | MECH_FLR_1 PEOPLE | BLDG_OCC_SCH | MECH_FLR_1 | 164.24 | 2.7 | 2.7 | 1.615E-002 | 61.932 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 3 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | BASEMENT_LIGHTS | LTG_SCH_BASEMENT | BASEMENT | 1978.83 | 106.5 | 17313.725 | 8.749 | 162.572 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 17313.725 |
2 | RETAIL_1_FLR_1_LIGHTS | LTG_SCH_RETAIL | RETAIL_1_FLR_1 | 67.07 | 10.8 | 872.757 | 13.012 | 80.594 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 872.757 |
3 | RETAIL_2_FLR_1_LIGHTS | LTG_SCH_RETAIL | RETAIL_2_FLR_1 | 77.67 | 12.5 | 1010.656 | 13.012 | 80.595 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1010.656 |
4 | MECH_FLR_1_LIGHTS | LTG_SCH_MECHANIC | MECH_FLR_1 | 164.24 | 2.7 | 1652.984 | 10.064 | 623.297 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1652.984 |
5 | STORAGE_FLR_1_LIGHTS | LTG_SCH_STORAGE | STORAGE_FLR_1 | 94.76 | 2.0 | 693.586 | 7.319 | 339.993 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 693.586 |
6 | LAUNDRY_FLR_1_LIGHTS | LTG_SCH_LAUNDRY | LAUNDRY_FLR_1 | 78.04 | 8.4 | 428.405 | 5.490 | 51.001 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 428.405 |
7 | CAFE_FLR_1_LIGHTS | LTG_SCH_DINING | CAFE_FLR_1 | 188.86 | 142.3 | 2419.140 | 12.809 | 17.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2419.140 |
8 | LOBBY_FLR_1_LIGHTS | LTG_SCH_LOBBY | LOBBY_FLR_1 | 1308.19 | 422.4 | 13165.908 | 10.064 | 31.167 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 13165.908 |
9 | ROOM_1_FLR_3_LIGHTS | LTG_SCH_GUESTROOM | ROOM_1_FLR_3 | 39.02 | 1.5 | 392.727 | 10.064 | 261.818 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 392.727 |
10 | ROOM_2_FLR_3_LIGHTS | LTG_SCH_GUESTROOM | ROOM_2_FLR_3 | 39.02 | 1.5 | 392.681 | 10.064 | 261.787 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 392.681 |
11 | ROOM_3_MULT19_FLR_3_LIGHTS | LTG_SCH_GUESTROOM | ROOM_3_MULT19_FLR_3 | 24.52 | 1.5 | 246.814 | 10.064 | 164.543 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 246.814 |
12 | ROOM_4_MULT19_FLR_3_LIGHTS | LTG_SCH_GUESTROOM | ROOM_4_MULT19_FLR_3 | 24.53 | 1.5 | 246.881 | 10.064 | 164.588 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 246.881 |
13 | ROOM_5_FLR_3_LIGHTS | LTG_SCH_GUESTROOM | ROOM_5_FLR_3 | 39.02 | 1.5 | 392.727 | 10.064 | 261.818 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 392.727 |
14 | ROOM_6_FLR_3_LIGHTS | LTG_SCH_GUESTROOM | ROOM_6_FLR_3 | 39.02 | 1.5 | 392.681 | 10.064 | 261.787 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 392.681 |
15 | CORRIDOR_FLR_3_LIGHTS | LTG_SCH_CORRIDOR | CORRIDOR_FLR_3 | 389.40 | 21.0 | 1425.114 | 3.660 | 68.002 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1425.114 |
16 | ROOM_1_FLR_6_LIGHTS | LTG_SCH_GUESTROOM | ROOM_1_FLR_6 | 39.02 | 1.5 | 392.727 | 10.064 | 261.818 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 392.727 |
17 | ROOM_2_FLR_6_LIGHTS | LTG_SCH_GUESTROOM | ROOM_2_FLR_6 | 39.02 | 1.5 | 392.681 | 10.064 | 261.787 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 392.681 |
18 | ROOM_3_MULT9_FLR_6_LIGHTS | LTG_SCH_GUESTROOM | ROOM_3_MULT9_FLR_6 | 24.53 | 1.5 | 246.881 | 10.064 | 164.588 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 246.881 |
19 | BANQUET_FLR_6_LIGHTS | LTG_SCH_DINING | BANQUET_FLR_6 | 331.66 | 249.9 | 4248.214 | 12.809 | 17.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 4248.214 |
20 | DINING_FLR_6_LIGHTS | LTG_SCH_DINING | DINING_FLR_6 | 331.66 | 249.9 | 4248.214 | 12.809 | 17.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 4248.214 |
21 | KITCHEN_FLR_6_LIGHTS | LTG_SCH_KITCHEN | KITCHEN_FLR_6 | 103.30 | 22.2 | 1134.198 | 10.979 | 51.003 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1134.198 |
22 | CORRIDOR_FLR_6_LIGHTS | LTG_SCH_CORRIDOR | CORRIDOR_FLR_6 | 412.12 | 22.2 | 1508.264 | 3.660 | 68.001 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1508.264 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | BASEMENT_MISCPLUG_EQUIP | BASEMENT_EQUIP_SCH | BASEMENT | 1978.83 | 106.5 | 10646.106 | 5.380 | 99.964 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 10646.106 |
2 | RETAIL_1_FLR_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | RETAIL_1_FLR_1 | 67.07 | 10.8 | 721.688 | 10.760 | 66.644 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 721.688 |
3 | RETAIL_2_FLR_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | RETAIL_2_FLR_1 | 77.67 | 12.5 | 835.717 | 10.760 | 66.644 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 835.717 |
4 | MECH_FLR_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | MECH_FLR_1 | 164.24 | 2.7 | 883.628 | 5.380 | 333.193 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 883.628 |
5 | STORAGE_FLR_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | STORAGE_FLR_1 | 94.76 | 2.0 | 254.902 | 2.690 | 124.952 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 254.902 |
6 | LAUNDRY_FLR_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | LAUNDRY_FLR_1 | 78.04 | 8.4 | 4813.474 | 61.680 | 573.033 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 4813.474 |
7 | CAFE_FLR_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CAFE_FLR_1 | 188.86 | 142.3 | 1016.077 | 5.380 | 7.140 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1016.077 |
8 | LOBBY_FLR_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | LOBBY_FLR_1 | 1308.19 | 422.4 | 10557.062 | 8.070 | 24.991 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 10557.062 |
9 | ROOM_1_FLR_3_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_1_FLR_3 | 39.02 | 1.5 | 263.399 | 6.750 | 175.599 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 263.399 |
10 | ROOM_2_FLR_3_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_2_FLR_3 | 39.02 | 1.5 | 263.368 | 6.750 | 175.579 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 263.368 |
11 | ROOM_3_MULT19_FLR_3_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_3_MULT19_FLR_3 | 24.52 | 1.5 | 257.991 | 10.520 | 171.994 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 257.991 |
12 | ROOM_4_MULT19_FLR_3_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_4_MULT19_FLR_3 | 24.53 | 1.5 | 258.061 | 10.520 | 172.041 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 258.061 |
13 | ROOM_5_FLR_3_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_5_FLR_3 | 39.02 | 1.5 | 263.399 | 6.750 | 175.599 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 263.399 |
14 | ROOM_6_FLR_3_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_6_FLR_3 | 39.02 | 1.5 | 263.368 | 6.750 | 175.579 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 263.368 |
15 | ROOM_1_FLR_6_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_1_FLR_6 | 39.02 | 1.5 | 263.399 | 6.750 | 175.599 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 263.399 |
16 | ROOM_2_FLR_6_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_2_FLR_6 | 39.02 | 1.5 | 263.368 | 6.750 | 175.579 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 263.368 |
17 | ROOM_3_MULT9_FLR_6_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_3_MULT9_FLR_6 | 24.53 | 1.5 | 258.061 | 10.520 | 172.041 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 258.061 |
18 | BANQUET_FLR_6_MISCPLUG_EQUIP | KITCHEN_ELEC_EQUIP_SCH | BANQUET_FLR_6 | 331.66 | 249.9 | 22493.008 | 67.820 | 90.009 | 0.000 | 0.500 | 0.000 | 0.500 | Cooking | 0.000 | 6747.903 |
19 | DINING_FLR_6_MISCPLUG_EQUIP | KITCHEN_ELEC_EQUIP_SCH | DINING_FLR_6 | 331.66 | 249.9 | 22493.008 | 67.820 | 90.009 | 0.000 | 0.500 | 0.000 | 0.500 | Cooking | 0.000 | 6747.903 |
20 | KITCHEN_FLR_6_MISCELEC_EQUIP | KITCHEN_ELEC_EQUIP_SCH | KITCHEN_FLR_6 | 103.30 | 22.2 | 52482.799 | 508.040 | 2360.050 | 0.200 | 0.500 | 0.100 | 0.200 | Cooking | 0.000 | 15744.840 |
21 | KITCHEN_FLR_6_REACH-IN-FREEZER | ALWAYS_ON | KITCHEN_FLR_6 | 103.30 | 22.2 | 515.917 | 4.994 | 23.200 | 0.000 | 0.250 | 0.000 | 0.750 | ReachInFreezer | 515.917 | 515.917 |
22 | KITCHEN_FLR_6_REACH-IN-REFRIGERATOR | ALWAYS_ON | KITCHEN_FLR_6 | 103.30 | 22.2 | 425.833 | 4.122 | 19.149 | 0.000 | 0.250 | 0.000 | 0.750 | ReachInRefrigerator | 425.833 | 425.833 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | LAUNDRY_FLR_1_MISCGAS_EQUIP | BLDG_EQUIP_SCH | LAUNDRY_FLR_1 | 78.04 | 8.4 | 41817.449 | 535.850 | 4978.268 | 0.000 | 0.500 | 0.000 | 0.500 | Laundry | 0.000 | 41817.449 |
2 | KITCHEN_FLR_6_MISCGAS_EQUIP | KITCHEN_GAS_EQUIP_SCH | KITCHEN_FLR_6 | 103.30 | 22.2 | 249920.353 | 2419.260 | 11238.437 | 0.100 | 0.200 | 0.700 | 0.000 | Cooking | 0.000 | 74976.106 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 3.464 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | OVERHEAD DOOR_CON | 2 | 1 | 1 | 0.167 | 1.198 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
3 | INTERIORFURNISHINGS | 3 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
4 | INT_WALL | 8 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | NONRES_ROOF | 18 | 3 | 3 | 0.167 | 0.2832 | 0.750 | 0.900 | 0.450 | 0.700 | Rough |
6 | RES_ROOF | 19 | 3 | 3 | 0.167 | 0.2832 | 0.750 | 0.900 | 0.450 | 0.700 | Rough |
7 | NONRES_EXT_WALL_GRD | 21 | 3 | 9 | 0.167 | 0.9686 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
8 | NONRES_EXT_WALL_MID | 22 | 3 | 9 | 0.167 | 1.265 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
9 | NONRES_EXT_WALL_TOP | 23 | 3 | 9 | 0.167 | 1.335 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
10 | RES_EXT_WALL_MID | 25 | 3 | 9 | 0.167 | 1.217 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
11 | RES_EXT_WALL_TOP | 26 | 3 | 9 | 0.167 | 1.286 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
12 | NONRES_FLOOR | 30 | 3 | 7 | 0.167 | 0.1963 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
13 | NONRES_FLOOR_CEILING | 33 | 3 | 7 | 0.167 | 0.1963 | 0.900 | 0.900 | 0.700 | 0.700 | VeryRough |
14 | BASEMENT_FLOOR | 36 | 2 | 7 | 0.333 | 2.705 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
15 | BASEMENT_WALL_NORTH_CFACTOR | 39 | 2 | 7 | 0.167 | 0.9401 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
16 | BASEMENT_WALL_EAST_CFACTOR | 40 | 2 | 7 | 0.167 | 0.9401 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
17 | BASEMENT_WALL_SOUTH_CFACTOR | 41 | 2 | 7 | 0.167 | 0.9401 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
18 | BASEMENT_WALL_WEST_CFACTOR | 42 | 2 | 7 | 0.167 | 0.9401 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2887 |
2 | OVERHEAD DOOR_CON PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.8346 |
3 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
6 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
7 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 3.472 |
8 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
9 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
10 | RES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 3.472 |
11 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
12 | 200MM NORMALWEIGHT CONCRETE WALL | 0.2032 | 2.310 | 2322.000 | 832.000 | 0.8797E-01 |
13 | NONRES_EXTERIOR_WALL_INSULATION_GRD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.8651 |
14 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
15 | 200MM NORMALWEIGHT CONCRETE WALL | 0.2032 | 2.310 | 2322.000 | 832.000 | 0.8797E-01 |
16 | NONRES_EXTERIOR_WALL_INSULATION_MID | 0.0000 | 0.000 | 0.000 | 0.000 | 0.6234 |
17 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
18 | 200MM NORMALWEIGHT CONCRETE WALL | 0.2032 | 2.310 | 2322.000 | 832.000 | 0.8797E-01 |
19 | NONRES_EXTERIOR_WALL_INSULATION_TOP | 0.0000 | 0.000 | 0.000 | 0.000 | 0.5819 |
20 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
21 | 200MM NORMALWEIGHT CONCRETE WALL | 0.2032 | 2.310 | 2322.000 | 832.000 | 0.8797E-01 |
22 | RES_EXTERIOR_WALL_INSULATION_MID | 0.0000 | 0.000 | 0.000 | 0.000 | 0.6546 |
23 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
24 | 200MM NORMALWEIGHT CONCRETE WALL | 0.2032 | 2.310 | 2322.000 | 832.000 | 0.8797E-01 |
25 | RES_EXTERIOR_WALL_INSULATION_TOP | 0.0000 | 0.000 | 0.000 | 0.000 | 0.6103 |
26 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
27 | NONRES_FLOOR_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 4.833 |
28 | 100MM NORMALWEIGHT CONCRETE FLOOR | 0.1016 | 2.310 | 2322.000 | 832.000 | 0.4398E-01 |
29 | CP02 CARPET PAD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2165 |
30 | CP02 CARPET PAD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2165 |
31 | 100MM NORMALWEIGHT CONCRETE FLOOR | 0.1016 | 2.310 | 2322.000 | 832.000 | 0.4398E-01 |
32 | NONRES_FLOOR_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 4.833 |
33 | M10 200MM CONCRETE BLOCK BASEMENT WALL | 0.2032 | 1.326 | 1842.000 | 912.000 | 0.1532 |
34 | CP02 CARPET PAD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2165 |
35 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 0.9868 |
36 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
37 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 0.9868 |
38 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
39 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 0.9868 |
40 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
41 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 0.9868 |
42 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 3.4637404 | 3.4637404 | 3.4637404 | |
3 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
4 | 0 | 1.1981135 | 1.1981135 | 1.1981135 | |
5 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
6 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
7 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
8 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
9 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
10 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
11 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
12 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
13 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
14 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
15 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
16 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
17 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
18 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
19 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
20 | 3 | -0.61927053E-06 | 0.12767249E-08 | -0.37968499E-05 | 0.16832131E-17 |
21 | 2 | 0.77611055 | 0.17315568E-02 | 1.0534842 | -0.72792597E-06 |
22 | 1 | -21.915918 | 0.11588205 | -6.3286394 | 0.20197014 |
23 | 0 | 21.365777 | 0.10835518 | 5.5011278 | |
24 | 3 | -0.61927053E-06 | 0.12767249E-08 | -0.37968499E-05 | 0.16832131E-17 |
25 | 2 | 0.77611055 | 0.17315568E-02 | 1.0534842 | -0.72792597E-06 |
26 | 1 | -21.915918 | 0.11588205 | -6.3286394 | 0.20197014 |
27 | 0 | 21.365777 | 0.10835518 | 5.5011278 | |
28 | 9 | 0.28610217E-16 | 0.32712183E-16 | -0.14788665E-09 | 0.15262255E-17 |
29 | 8 | 0.21617198E-07 | 0.13019051E-12 | 0.37508535E-03 | -0.24579497E-09 |
30 | 7 | -0.12160768E-01 | 0.67781631E-08 | -0.22969495E-01 | 0.13827236E-03 |
31 | 6 | 0.40315523 | 0.23644201E-05 | 0.47022156 | -0.47218870E-02 |
32 | 5 | -5.1691419 | 0.88489975E-04 | -4.4269034 | 0.62918229E-01 |
33 | 4 | 32.908103 | 0.72540386E-03 | 21.384224 | -0.42086483 |
34 | 3 | -111.02464 | 0.15839520E-02 | -55.513084 | 1.5122822 |
35 | 2 | 196.93145 | 0.89247901E-03 | 77.773085 | -2.8975455 |
36 | 1 | -171.09078 | 0.95424204E-04 | -55.225093 | 2.7442950 |
37 | 0 | 57.057407 | 0.54416031E-06 | 15.563533 | |
38 | 9 | 0.16021817E-14 | 0.43623596E-16 | -0.13387302E-09 | -0.38399267E-17 |
39 | 8 | 0.19641607E-07 | 0.16693997E-12 | 0.35391383E-03 | -0.22333182E-09 |
40 | 7 | -0.11527600E-01 | 0.88905521E-08 | -0.22057378E-01 | 0.13107300E-03 |
41 | 6 | 0.38594887 | 0.31296587E-05 | 0.45553223 | -0.45190661E-02 |
42 | 5 | -5.0012033 | 0.11804975E-03 | -4.3139252 | 0.60835889E-01 |
43 | 4 | 32.165114 | 0.97455506E-03 | 20.942266 | -0.41100022 |
44 | 3 | -109.44341 | 0.21413112E-02 | -54.639172 | 1.4894383 |
45 | 2 | 195.36376 | 0.12132308E-02 | 76.972220 | -2.8726514 |
46 | 1 | -170.51151 | 0.13038514E-03 | -54.993414 | 2.7341426 |
47 | 0 | 57.057407 | 0.74764616E-06 | 15.602778 | |
48 | 9 | 0.89845624E-15 | 0.45148486E-16 | -0.13053700E-09 | -0.34170761E-17 |
49 | 8 | 0.19169472E-07 | 0.17528607E-12 | 0.34874871E-03 | -0.21796351E-09 |
50 | 7 | -0.11372769E-01 | 0.93896549E-08 | -0.21834212E-01 | 0.12931251E-03 |
51 | 6 | 0.38174081 | 0.33130355E-05 | 0.45193069 | -0.44694638E-02 |
52 | 5 | -4.9601253 | 0.12521571E-03 | -4.2861852 | 0.60326552E-01 |
53 | 4 | 31.983339 | 0.10355575E-02 | 20.833661 | -0.40858686 |
54 | 3 | -109.05644 | 0.22789331E-02 | -54.424381 | 1.4838481 |
55 | 2 | 194.97998 | 0.12930063E-02 | 76.775547 | -2.8665574 |
56 | 1 | -170.36965 | 0.13913733E-03 | -54.936825 | 2.7316564 |
57 | 0 | 57.057407 | 0.79895123E-06 | 15.612614 | |
58 | 9 | 0.12430042E-14 | 0.43603463E-16 | -0.13615479E-09 | -0.52742981E-17 |
59 | 8 | 0.19963588E-07 | 0.16114398E-12 | 0.35741204E-03 | -0.22699287E-09 |
60 | 7 | -0.11632381E-01 | 0.85488282E-08 | -0.22208377E-01 | 0.13226440E-03 |
61 | 6 | 0.38879653 | 0.30047059E-05 | 0.45796739 | -0.45526330E-02 |
62 | 5 | -5.0290001 | 0.11318598E-03 | -4.3326723 | 0.61180550E-01 |
63 | 4 | 32.288109 | 0.93328928E-03 | 21.015642 | -0.41263319 |
64 | 3 | -109.70522 | 0.20484795E-02 | -54.784283 | 1.4932205 |
65 | 2 | 195.62339 | 0.11595496E-02 | 77.105128 | -2.8767741 |
66 | 1 | -170.60747 | 0.12450863E-03 | -55.031726 | 2.7358244 |
67 | 0 | 57.057407 | 0.71328115E-06 | 15.596176 | |
68 | 9 | 0.10418955E-14 | 0.45554749E-16 | -0.13285794E-09 | -0.34221686E-17 |
69 | 8 | 0.19498290E-07 | 0.16949498E-12 | 0.35235048E-03 | -0.22170227E-09 |
70 | 7 | -0.11480752E-01 | 0.90423087E-08 | -0.21989859E-01 | 0.13054032E-03 |
71 | 6 | 0.38467563 | 0.31853038E-05 | 0.45444290 | -0.45040579E-02 |
72 | 5 | -4.9887746 | 0.12022067E-03 | -4.3055366 | 0.60681782E-01 |
73 | 4 | 32.110117 | 0.99300969E-03 | 20.909427 | -0.41027004 |
74 | 3 | -109.32633 | 0.21828955E-02 | -54.574228 | 1.4877470 |
75 | 2 | 195.24766 | 0.12373115E-02 | 76.912747 | -2.8708078 |
76 | 1 | -170.46860 | 0.13302463E-03 | -54.976289 | 2.7333905 |
77 | 0 | 57.057407 | 0.76310210E-06 | 15.605744 | |
78 | 7 | -0.15963512E-14 | -0.15187529E-16 | -0.22427203E-13 | 0.56155309E-15 |
79 | 6 | 0.17983713E-10 | 0.23594901E-11 | 0.52322926E-09 | -0.18637893E-10 |
80 | 5 | -0.60139213E-07 | 0.11510628E-07 | -0.21924491E-05 | 0.17161312E-06 |
81 | 4 | 0.62746279E-04 | 0.43399923E-05 | 0.17681060E-02 | -0.28244642E-03 |
82 | 3 | -0.90508353E-02 | 0.15320797E-03 | -0.21560640 | 0.43341486E-01 |
83 | 2 | 0.12836503 | 0.66328859E-03 | 2.9007871 | -0.61911613 |
84 | 1 | -0.32478029 | 0.41934727E-03 | -7.1379041 | 1.5697129 |
85 | 0 | 0.20664896 | 0.54311639E-05 | 4.4522013 | |
86 | 7 | -0.22427203E-13 | -0.15187529E-16 | -0.15963512E-14 | 0.56155309E-15 |
87 | 6 | 0.52322926E-09 | 0.23594901E-11 | 0.17983713E-10 | -0.18637893E-10 |
88 | 5 | -0.21924491E-05 | 0.11510628E-07 | -0.60139213E-07 | 0.17161312E-06 |
89 | 4 | 0.17681060E-02 | 0.43399923E-05 | 0.62746279E-04 | -0.28244642E-03 |
90 | 3 | -0.21560640 | 0.15320797E-03 | -0.90508353E-02 | 0.43341486E-01 |
91 | 2 | 2.9007871 | 0.66328859E-03 | 0.12836503 | -0.61911613 |
92 | 1 | -7.1379041 | 0.41934727E-03 | -0.32478029 | 1.5697129 |
93 | 0 | 4.4522013 | 0.54311639E-05 | 0.20664896 | |
94 | 7 | -0.52459208E-15 | -0.63961428E-15 | -0.12292524E-09 | -0.35846135E-17 |
95 | 6 | 0.39860198E-02 | 0.96339020E-07 | 0.40499006E-03 | -0.70890431E-04 |
96 | 5 | -0.20832379 | 0.49172556E-04 | -0.20585669E-01 | 0.38489246E-02 |
97 | 4 | 3.5198270 | 0.18993977E-02 | 0.34924834 | -0.69168259E-01 |
98 | 3 | -23.366787 | 0.13311857E-01 | -2.4329538 | 0.50524779 |
99 | 2 | 64.890127 | 0.19943872E-01 | 7.3672511 | -1.5911358 |
100 | 1 | -76.040094 | 0.56792084E-02 | -9.5568013 | 2.1361271 |
101 | 0 | 31.242244 | 0.96490710E-04 | 4.3344156 | |
102 | 7 | -0.41493644E-09 | 0.26375357E-16 | 0.26213203E-14 | -0.63268016E-17 |
103 | 6 | 0.27465604E-04 | 0.18700671E-07 | 0.31288692E-02 | -0.26247577E-04 |
104 | 5 | -0.19935291E-02 | 0.11146933E-04 | -0.22025565 | 0.19255324E-02 |
105 | 4 | 0.45890804E-01 | 0.50864553E-03 | 4.7717348 | -0.44709298E-01 |
106 | 3 | -0.40280019 | 0.40571884E-02 | -37.694667 | 0.39504237 |
107 | 2 | 1.4296488 | 0.67623010E-02 | 115.84777 | -1.4094303 |
108 | 1 | -2.0629154 | 0.20697549E-02 | -143.53273 | 2.0428830 |
109 | 0 | 1.0055995 | 0.48413807E-04 | 60.838472 | |
110 | 7 | -0.41493644E-09 | 0.26375357E-16 | 0.26213203E-14 | -0.63268016E-17 |
111 | 6 | 0.27465604E-04 | 0.18700671E-07 | 0.31288692E-02 | -0.26247577E-04 |
112 | 5 | -0.19935291E-02 | 0.11146933E-04 | -0.22025565 | 0.19255324E-02 |
113 | 4 | 0.45890804E-01 | 0.50864553E-03 | 4.7717348 | -0.44709298E-01 |
114 | 3 | -0.40280019 | 0.40571884E-02 | -37.694667 | 0.39504237 |
115 | 2 | 1.4296488 | 0.67623010E-02 | 115.84777 | -1.4094303 |
116 | 1 | -2.0629154 | 0.20697549E-02 | -143.53273 | 2.0428830 |
117 | 0 | 1.0055995 | 0.48413807E-04 | 60.838472 | |
118 | 7 | -0.41493644E-09 | 0.26375357E-16 | 0.26213203E-14 | -0.63268016E-17 |
119 | 6 | 0.27465604E-04 | 0.18700671E-07 | 0.31288692E-02 | -0.26247577E-04 |
120 | 5 | -0.19935291E-02 | 0.11146933E-04 | -0.22025565 | 0.19255324E-02 |
121 | 4 | 0.45890804E-01 | 0.50864553E-03 | 4.7717348 | -0.44709298E-01 |
122 | 3 | -0.40280019 | 0.40571884E-02 | -37.694667 | 0.39504237 |
123 | 2 | 1.4296488 | 0.67623010E-02 | 115.84777 | -1.4094303 |
124 | 1 | -2.0629154 | 0.20697549E-02 | -143.53273 | 2.0428830 |
125 | 0 | 1.0055995 | 0.48413807E-04 | 60.838472 | |
126 | 7 | -0.41493644E-09 | 0.26375357E-16 | 0.26213203E-14 | -0.63268016E-17 |
127 | 6 | 0.27465604E-04 | 0.18700671E-07 | 0.31288692E-02 | -0.26247577E-04 |
128 | 5 | -0.19935291E-02 | 0.11146933E-04 | -0.22025565 | 0.19255324E-02 |
129 | 4 | 0.45890804E-01 | 0.50864553E-03 | 4.7717348 | -0.44709298E-01 |
130 | 3 | -0.40280019 | 0.40571884E-02 | -37.694667 | 0.39504237 |
131 | 2 | 1.4296488 | 0.67623010E-02 | 115.84777 | -1.4094303 |
132 | 1 | -2.0629154 | 0.20697549E-02 | -143.53273 | 2.0428830 |
133 | 0 | 1.0055995 | 0.48413807E-04 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | Conductance (Before Adjusted) {W/m2-K} | Convection Coefficient Adjustment Ratio | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.4711_SHGC_0.25 | 37 | 1 | VerySmooth | 2.678 | 2.678 | 1.000 | 0.251 | ||
2 | RESWINDOW_U_0.4711_SHGC_0.25 | 38 | 1 | VerySmooth | 2.678 | 2.678 | 1.000 | 0.251 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | GLAZING LAYER | SpectralAverage | 2.39142E-002 | 0.16139 | 0.61472 | 0.61472 | 0.25000 | 0.16143 | 0.23877 | 0.00000 | 0.84000 | 0.84000 | 0.11798 | 1.00000 | No | |
2 | RESIDENTIAL WINDOW GLAZING LAYER | SpectralAverage | 2.39142E-002 | 0.16139 | 0.61472 | 0.61472 | 0.25000 | 0.16143 | 0.23877 | 0.00000 | 0.84000 | 0.84000 | 0.11798 | 1.00000 | No |
Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | PolygonClipping | Periodic | 7 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
Number of Refrigeration Compressor Racks | |
1 | 2 |
Compressor Rack Name | # Refrigerated Cases Connected | # WalkIn Coolers Connected | Heat Rejection Location | Condenser Type | COP | |
1 | RACK1 | 1 | 0 | Zone | Air-Cooled | 1.500 |
2 | RACK2 | 1 | 0 | Zone | Air-Cooled | 3.000 |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | SWH BOOSTER E WATER HEATER | 2.2712E-002 | 8000.0 | 1.240 | 1.1473 |
2 | WaterHeater:Mixed | SWH LAUNDRY G WATER HEATER | 1.1356 | 163316.0 | 0.576 | 0.5074 |
3 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | 2.2712 | 175842.6 | 0.260 | 2.5713E-002 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | BASEMENT_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
2 | BASEMENT_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
3 | BASEMENT_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
4 | BASEMENT_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
5 | BASEMENT_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
6 | BASEMENT_CEILING_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
7 | BASEMENT_CEILING_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
8 | BASEMENT_CEILING_3 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
9 | BASEMENT_CEILING_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
10 | BASEMENT_CEILING_5 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
11 | BASEMENT_CEILING_6 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
12 | BASEMENT_CEILING_7 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
13 | BASEMENT_CEILING_8 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
14 | BASEMENT_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
15 | RETAIL_1_FLR_1_WALL_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.96 | 17.37 | 7.72 | 0.34 | 4 | No | No |
16 | RETAIL_1_FLR_1_WALL_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.96 | 17.37 | 7.72 | 0.34 | 1 | No | No |
17 | RETAIL_1_FLR_1_WALL_WEST | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.96 | 17.37 | 7.72 | 0.34 | 3 | No | No |
18 | RETAIL_1_FLR_1_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 17.37 | 7.72 | 0.34 | 0 | No | No |
19 | RETAIL_1_FLR_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 17.37 | 7.72 | 0.34 | 0 | No | No |
20 | RETAIL_1_FLR_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 17.37 | 7.72 | 0.34 | 0 | No | No |
21 | RETAIL_1_FLR_1_CEILING | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.96 | 17.37 | 7.72 | 0.34 | 0 | No | No |
22 | RETAIL_1_FLR_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 17.37 | 7.72 | 0.34 | 0 | No | No |
23 | RETAIL_2_FLR_1_WALL_WEST | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.96 | 6.71 | 8.49 | 0.00 | 0 | No | No |
24 | RETAIL_2_FLR_1_WALL_WEST_DOOR | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.96 | 6.71 | 8.49 | 0.00 | 0 | No | No |
25 | RETAIL_2_FLR_1_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 6.71 | 8.49 | 0.00 | 0 | No | No |
26 | RETAIL_2_FLR_1_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 6.71 | 8.49 | 0.00 | 0 | No | No |
27 | RETAIL_2_FLR_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 6.71 | 8.49 | 0.00 | 0 | No | No |
28 | RETAIL_2_FLR_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 6.71 | 8.49 | 0.00 | 0 | No | No |
29 | RETAIL_2_FLR_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 6.71 | 8.49 | 0.00 | 0 | No | No |
30 | RETAIL_2_FLR_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 6.71 | 8.49 | 0.00 | 0 | No | No |
31 | MECH_FLR_1_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.96 | 15.85 | 12.53 | 0.00 | 0 | No | No |
32 | MECH_FLR_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 15.85 | 12.53 | 0.00 | 0 | No | No |
33 | MECH_FLR_1_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 15.85 | 12.53 | 0.00 | 0 | No | No |
34 | MECH_FLR_1_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 15.85 | 12.53 | 0.00 | 0 | No | No |
35 | MECH_FLR_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 15.85 | 12.53 | 0.00 | 0 | No | No |
36 | MECH_FLR_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 15.85 | 12.53 | 0.00 | 0 | No | No |
37 | MECH_FLR_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 15.85 | 12.53 | 0.00 | 0 | No | No |
38 | STORAGE_FLR_1_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.96 | 9.14 | 9.72 | 0.00 | 0 | No | No |
39 | STORAGE_FLR_1_WALL_NORTH_ROLLDOOR | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.96 | 9.14 | 9.72 | 0.00 | 0 | No | No |
40 | STORAGE_FLR_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 9.14 | 9.72 | 0.00 | 0 | No | No |
41 | STORAGE_FLR_1_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 9.14 | 9.72 | 0.00 | 0 | No | No |
42 | STORAGE_FLR_1_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 9.14 | 9.72 | 0.00 | 0 | No | No |
43 | STORAGE_FLR_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 9.14 | 9.72 | 0.00 | 0 | No | No |
44 | STORAGE_FLR_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 9.14 | 9.72 | 0.00 | 0 | No | No |
45 | STORAGE_FLR_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 9.14 | 9.72 | 0.00 | 0 | No | No |
46 | LAUNDRY_FLR_1_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.96 | 21.64 | 7.21 | 0.00 | 0 | No | No |
47 | LAUNDRY_FLR_1_WALL_EAST | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.96 | 21.64 | 7.21 | 0.00 | 0 | No | No |
48 | LAUNDRY_FLR_1_WALL_EAST_DOOR | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.96 | 21.64 | 7.21 | 0.00 | 0 | No | No |
49 | LAUNDRY_FLR_1_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 21.64 | 7.21 | 0.00 | 0 | No | No |
50 | LAUNDRY_FLR_1_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 21.64 | 7.21 | 0.00 | 0 | No | No |
51 | LAUNDRY_FLR_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 21.64 | 7.21 | 0.00 | 0 | No | No |
52 | LAUNDRY_FLR_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 21.64 | 7.21 | 0.00 | 0 | No | No |
53 | LAUNDRY_FLR_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 21.64 | 7.21 | 0.00 | 0 | No | No |
54 | CAFE_FLR_1_WALL_EAST | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 3 | No | No |
55 | CAFE_FLR_1_WALL_EAST_DOOR | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 0 | No | No |
56 | CAFE_FLR_1_WALL_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 4 | No | No |
57 | CAFE_FLR_1_WALL_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 1 | No | No |
58 | CAFE_FLR_1_WALL_1_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 0 | No | No |
59 | CAFE_FLR_1_WALL_2_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 0 | No | No |
60 | CAFE_FLR_1_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 0 | No | No |
61 | CAFE_FLR_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 0 | No | No |
62 | CAFE_FLR_1_CEILING | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 0 | No | No |
63 | CAFE_FLR_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 0 | No | No |
64 | LOBBY_FLR_1_WALL_1_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 3 | No | No |
65 | LOBBY_FLR_1_WALL_1_NORTH_DOOR1 | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
66 | LOBBY_FLR_1_WALL_1_NORTH_DOOR2 | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
67 | LOBBY_FLR_1_WALL_2_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 4 | No | No |
68 | LOBBY_FLR_1_WALL_1_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 4 | No | No |
69 | LOBBY_FLR_1_WALL_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 1 | No | No |
70 | LOBBY_FLR_1_WALL_1_WEST | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 3 | No | No |
71 | LOBBY_FLR_1_WALL_2_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
72 | LOBBY_FLR_1_WALL_3_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
73 | LOBBY_FLR_1_WALL_2_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
74 | LOBBY_FLR_1_WALL_3_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
75 | LOBBY_FLR_1_WALL_4_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
76 | LOBBY_FLR_1_WALL_3_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
77 | LOBBY_FLR_1_WALL_4_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
78 | LOBBY_FLR_1_WALL_1_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
79 | LOBBY_FLR_1_WALL_2_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
80 | LOBBY_FLR_1_WALL_3_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
81 | LOBBY_FLR_1_FLOOR_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
82 | LOBBY_FLR_1_FLOOR_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
83 | LOBBY_FLR_1_CEILING_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
84 | LOBBY_FLR_1_CEILING_2 | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
85 | LOBBY_FLR_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
86 | ROOM_1_FLR_3_WALL_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
87 | ROOM_1_FLR_3_WALL_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
88 | ROOM_1_FLR_3_WALL_WEST | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
89 | ROOM_1_FLR_3_WALL_WEST_WINDOW | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
90 | ROOM_1_FLR_3_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
91 | ROOM_1_FLR_3_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
92 | ROOM_1_FLR_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
93 | ROOM_1_FLR_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
94 | ROOM_1_FLR_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
95 | ROOM_2_FLR_3_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
96 | ROOM_2_FLR_3_WALL_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
97 | ROOM_2_FLR_3_WALL_WEST | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
98 | ROOM_2_FLR_3_WALL_WEST_WINDOW | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
99 | ROOM_2_FLR_3_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
100 | ROOM_2_FLR_3_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
101 | ROOM_2_FLR_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
102 | ROOM_2_FLR_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
103 | ROOM_2_FLR_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
104 | ROOM_3_MULT19_FLR_3_WALL_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 3 | No | No |
105 | ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 2 | No | No |
106 | ROOM_3_MULT19_FLR_3_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
107 | ROOM_3_MULT19_FLR_3_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
108 | ROOM_3_MULT19_FLR_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
109 | ROOM_3_MULT19_FLR_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
110 | ROOM_3_MULT19_FLR_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
111 | ROOM_3_MULT19_FLR_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
112 | ROOM_4_MULT19_FLR_3_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 3 | No | No |
113 | ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 2 | No | No |
114 | ROOM_4_MULT19_FLR_3_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
115 | ROOM_4_MULT19_FLR_3_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
116 | ROOM_4_MULT19_FLR_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
117 | ROOM_4_MULT19_FLR_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
118 | ROOM_4_MULT19_FLR_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
119 | ROOM_4_MULT19_FLR_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
120 | ROOM_5_FLR_3_WALL_EAST | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
121 | ROOM_5_FLR_3_WALL_EAST_WINDOW | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
122 | ROOM_5_FLR_3_WALL_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
123 | ROOM_5_FLR_3_WALL_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
124 | ROOM_5_FLR_3_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
125 | ROOM_5_FLR_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
126 | ROOM_5_FLR_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
127 | ROOM_5_FLR_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
128 | ROOM_5_FLR_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
129 | ROOM_6_FLR_3_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
130 | ROOM_6_FLR_3_WALL_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
131 | ROOM_6_FLR_3_WALL_EAST | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
132 | ROOM_6_FLR_3_WALL_EAST_WINDOW | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
133 | ROOM_6_FLR_3_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
134 | ROOM_6_FLR_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
135 | ROOM_6_FLR_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
136 | ROOM_6_FLR_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
137 | ROOM_6_FLR_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
138 | CORRIDOR_FLR_3_WALL_1_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 3 | No | No |
139 | CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 2 | No | No |
140 | CORRIDOR_FLR_3_WALL_2_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 3 | No | No |
141 | CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 2 | No | No |
142 | CORRIDOR_FLR_3_WALL_1_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 3 | No | No |
143 | CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 2 | No | No |
144 | CORRIDOR_FLR_3_WALL_2_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 3 | No | No |
145 | CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 2 | No | No |
146 | CORRIDOR_FLR_3_WALL_3_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
147 | CORRIDOR_FLR_3_WALL_1_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
148 | CORRIDOR_FLR_3_WALL_2_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
149 | CORRIDOR_FLR_3_WALL_3_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
150 | CORRIDOR_FLR_3_WALL_4_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
151 | CORRIDOR_FLR_3_WALL_3_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
152 | CORRIDOR_FLR_3_WALL_1_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
153 | CORRIDOR_FLR_3_WALL_2_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
154 | CORRIDOR_FLR_3_WALL_3_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
155 | CORRIDOR_FLR_3_WALL_4_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
156 | CORRIDOR_FLR_3_FLOOR_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
157 | CORRIDOR_FLR_3_FLOOR_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
158 | CORRIDOR_FLR_3_FLOOR_3 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
159 | CORRIDOR_FLR_3_CEILING_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
160 | CORRIDOR_FLR_3_CEILING_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
161 | CORRIDOR_FLR_3_CEILING_3 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
162 | CORRIDOR_FLR_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
163 | ROOM_1_FLR_6_WALL_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
164 | ROOM_1_FLR_6_WALL_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
165 | ROOM_1_FLR_6_WALL_WEST | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
166 | ROOM_1_FLR_6_WALL_WEST_WINDOW | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
167 | ROOM_1_FLR_6_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
168 | ROOM_1_FLR_6_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
169 | ROOM_1_FLR_6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
170 | ROOM_1_FLR_6_CEILING | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
171 | ROOM_1_FLR_6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
172 | ROOM_2_FLR_6_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
173 | ROOM_2_FLR_6_WALL_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
174 | ROOM_2_FLR_6_WALL_WEST | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
175 | ROOM_2_FLR_6_WALL_WEST_WINDOW | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
176 | ROOM_2_FLR_6_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
177 | ROOM_2_FLR_6_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
178 | ROOM_2_FLR_6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
179 | ROOM_2_FLR_6_CEILING | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
180 | ROOM_2_FLR_6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
181 | ROOM_3_MULT9_FLR_6_WALL_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 6.71 | 4.73 | 0.33 | 3 | No | No |
182 | ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 6.71 | 4.73 | 0.33 | 2 | No | No |
183 | ROOM_3_MULT9_FLR_6_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 6.71 | 4.73 | 0.33 | 0 | No | No |
184 | ROOM_3_MULT9_FLR_6_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 6.71 | 4.73 | 0.33 | 0 | No | No |
185 | ROOM_3_MULT9_FLR_6_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 6.71 | 4.73 | 0.33 | 0 | No | No |
186 | ROOM_3_MULT9_FLR_6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 6.71 | 4.73 | 0.33 | 0 | No | No |
187 | ROOM_3_MULT9_FLR_6_CEILING | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.05 | 6.71 | 4.73 | 0.33 | 0 | No | No |
188 | ROOM_3_MULT9_FLR_6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 6.71 | 4.73 | 0.33 | 0 | No | No |
189 | BANQUET_FLR_6_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 3 | No | No |
190 | BANQUET_FLR_6_WALL_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 2 | No | No |
191 | BANQUET_FLR_6_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
192 | BANQUET_FLR_6_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
193 | BANQUET_FLR_6_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
194 | BANQUET_FLR_6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
195 | BANQUET_FLR_6_CEILING | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
196 | BANQUET_FLR_6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
197 | DINING_FLR_6_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 3 | No | No |
198 | DINING_FLR_6_WALL_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 2 | No | No |
199 | DINING_FLR_6_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
200 | DINING_FLR_6_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
201 | DINING_FLR_6_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
202 | DINING_FLR_6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
203 | DINING_FLR_6_CEILING | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
204 | DINING_FLR_6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
205 | KITCHEN_FLR_6_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 3 | No | No |
206 | KITCHEN_FLR_6_WALL_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 2 | No | No |
207 | KITCHEN_FLR_6_WALL_EAST | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 3 | No | No |
208 | KITCHEN_FLR_6_WALL_EAST_WINDOW | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 2 | No | No |
209 | KITCHEN_FLR_6_WALL_1_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 3 | No | No |
210 | KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 2 | No | No |
211 | KITCHEN_FLR_6_WALL_2_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 0 | No | No |
212 | KITCHEN_FLR_6_WALL_1_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 0 | No | No |
213 | KITCHEN_FLR_6_WALL_2_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 0 | No | No |
214 | KITCHEN_FLR_6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 0 | No | No |
215 | KITCHEN_FLR_6_CEILING | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 0 | No | No |
216 | KITCHEN_FLR_6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 0 | No | No |
217 | CORRIDOR_FLR_6_WALL_1_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 3 | No | No |
218 | CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 2 | No | No |
219 | CORRIDOR_FLR_6_WALL_2_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 3 | No | No |
220 | CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 2 | No | No |
221 | CORRIDOR_FLR_6_WALL_2_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 3 | No | No |
222 | CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 2 | No | No |
223 | CORRIDOR_FLR_6_WALL_3_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
224 | CORRIDOR_FLR_6_WALL_4_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
225 | CORRIDOR_FLR_6_WALL_1_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
226 | CORRIDOR_FLR_6_WALL_1_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
227 | CORRIDOR_FLR_6_WALL_2_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
228 | CORRIDOR_FLR_6_WALL_3_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
229 | CORRIDOR_FLR_6_WALL_1_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
230 | CORRIDOR_FLR_6_WALL_2_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
231 | CORRIDOR_FLR_6_WALL_3_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
232 | CORRIDOR_FLR_6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
233 | CORRIDOR_FLR_6_CEILING_1 | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
234 | CORRIDOR_FLR_6_CEILING_2 | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
235 | CORRIDOR_FLR_6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | RETAIL_1_FLR_1_INFILTRATION | INFIL_QUARTER_ON_SCH | RETAIL_1_FLR_1 | 67.07 | 10.8 | 7.058E-002 | 1.052E-003 | 5.193E-004 | 0.956 | 1.000 | 0.000 | 0.000 | 0.000 |
2 | RETAIL_2_FLR_1_INFILTRATION | INFIL_QUARTER_ON_SCH | RETAIL_2_FLR_1 | 77.67 | 12.5 | 2.724E-002 | 3.507E-004 | 9.551E-004 | 0.319 | 1.000 | 0.000 | 0.000 | 0.000 |
3 | MECH_FLR_1_INFILTRATION | INFIL_QUARTER_ON_SCH | MECH_FLR_1 | 164.24 | 2.7 | 6.438E-002 | 3.920E-004 | 1.025E-003 | 0.356 | 1.000 | 0.000 | 0.000 | 0.000 |
4 | STORAGE_FLR_1_INFILTRATION | INFIL_QUARTER_ON_SCH | STORAGE_FLR_1 | 94.76 | 2.0 | 3.715E-002 | 3.920E-004 | 8.507E-004 | 0.356 | 1.000 | 0.000 | 0.000 | 0.000 |
5 | LAUNDRY_FLR_1_INFILTRATION | INFIL_QUARTER_ON_SCH | LAUNDRY_FLR_1 | 78.04 | 8.4 | 8.791E-002 | 1.127E-003 | 1.002E-003 | 1.023 | 1.000 | 0.000 | 0.000 | 0.000 |
6 | CAFE_FLR_1_INFILTRATION | INFIL_QUARTER_ON_SCH | CAFE_FLR_1 | 188.86 | 142.3 | 0.156 | 8.261E-004 | 4.549E-004 | 0.751 | 1.000 | 0.000 | 0.000 | 0.000 |
7 | LOBBY_FLR_1_INFILTRATION | INFIL_QUARTER_ON_SCH | LOBBY_FLR_1 | 1308.19 | 422.4 | 0.446 | 3.407E-004 | 6.517E-004 | 0.310 | 1.000 | 0.000 | 0.000 | 0.000 |
8 | ROOM_1_FLR_3_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_1_FLR_3 | 39.02 | 1.5 | 4.096E-002 | 1.050E-003 | 1.025E-003 | 1.240 | 1.000 | 0.000 | 0.000 | 0.000 |
9 | ROOM_2_FLR_3_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_2_FLR_3 | 39.02 | 1.5 | 4.095E-002 | 1.050E-003 | 1.025E-003 | 1.240 | 1.000 | 0.000 | 0.000 | 0.000 |
10 | ROOM_3_MULT19_FLR_3_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_3_MULT19_FLR_3 | 24.52 | 1.5 | 1.143E-002 | 4.660E-004 | 1.025E-003 | 0.550 | 1.000 | 0.000 | 0.000 | 0.000 |
11 | ROOM_4_MULT19_FLR_3_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_4_MULT19_FLR_3 | 24.53 | 1.5 | 1.143E-002 | 4.660E-004 | 1.025E-003 | 0.550 | 1.000 | 0.000 | 0.000 | 0.000 |
12 | ROOM_5_FLR_3_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_5_FLR_3 | 39.02 | 1.5 | 4.096E-002 | 1.050E-003 | 1.025E-003 | 1.240 | 1.000 | 0.000 | 0.000 | 0.000 |
13 | ROOM_6_FLR_3_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_6_FLR_3 | 39.02 | 1.5 | 4.095E-002 | 1.050E-003 | 1.025E-003 | 1.240 | 1.000 | 0.000 | 0.000 | 0.000 |
14 | CORRIDOR_FLR_3_INFILTRATION | INFIL_QUARTER_ON_SCH | CORRIDOR_FLR_3 | 389.40 | 21.0 | 4.953E-002 | 1.272E-004 | 1.025E-003 | 0.150 | 1.000 | 0.000 | 0.000 | 0.000 |
15 | ROOM_1_FLR_6_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_1_FLR_6 | 39.02 | 1.5 | 4.096E-002 | 1.050E-003 | 5.186E-004 | 1.240 | 1.000 | 0.000 | 0.000 | 0.000 |
16 | ROOM_2_FLR_6_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_2_FLR_6 | 39.02 | 1.5 | 4.095E-002 | 1.050E-003 | 5.186E-004 | 1.240 | 1.000 | 0.000 | 0.000 | 0.000 |
17 | ROOM_3_MULT9_FLR_6_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_3_MULT9_FLR_6 | 24.53 | 1.5 | 2.096E-002 | 8.543E-004 | 4.660E-004 | 1.009 | 1.000 | 0.000 | 0.000 | 0.000 |
18 | BANQUET_FLR_6_INFILTRATION | INFIL_QUARTER_ON_SCH | BANQUET_FLR_6 | 331.66 | 249.9 | 0.100 | 3.015E-004 | 2.330E-004 | 0.356 | 1.000 | 0.000 | 0.000 | 0.000 |
19 | DINING_FLR_6_INFILTRATION | INFIL_QUARTER_ON_SCH | DINING_FLR_6 | 331.66 | 249.9 | 0.100 | 3.015E-004 | 2.330E-004 | 0.356 | 1.000 | 0.000 | 0.000 | 0.000 |
20 | KITCHEN_FLR_6_INFILTRATION | INFIL_QUARTER_ON_SCH | KITCHEN_FLR_6 | 103.30 | 22.2 | 8.953E-002 | 8.667E-004 | 4.697E-004 | 1.024 | 1.000 | 0.000 | 0.000 | 0.000 |
21 | CORRIDOR_FLR_6_INFILTRATION | INFIL_QUARTER_ON_SCH | CORRIDOR_FLR_6 | 412.12 | 22.2 | 8.763E-002 | 2.126E-004 | 1.761E-004 | 0.251 | 1.000 | 0.000 | 0.000 | 0.000 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/person Area {m3/s-person} | ACH - Air Changes per Hour | Fan Type {Exhaust;Intake;Natural} | Fan Pressure Rise {Pa} | Fan Efficiency {} | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | Minimum Indoor Temperature{C}/Schedule | Maximum Indoor Temperature{C}/Schedule | Delta Temperature{C}/Schedule | Minimum Outdoor Temperature{C}/Schedule | Maximum Outdoor Temperature{C}/Schedule | Maximum WindSpeed{m/s} | |
1 | ROOM_1_FLR_3 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_1_FLR_3 | 39.02 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
2 | ROOM_2_FLR_3 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_2_FLR_3 | 39.02 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
3 | ROOM_3_MULT19_FLR_3 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_3_MULT19_FLR_3 | 24.52 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
4 | ROOM_4_MULT19_FLR_3 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_4_MULT19_FLR_3 | 24.53 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
5 | ROOM_5_FLR_3 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_5_FLR_3 | 39.02 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
6 | ROOM_6_FLR_3 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_6_FLR_3 | 39.02 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
7 | ROOM_1_FLR_6 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_1_FLR_6 | 39.02 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
8 | ROOM_2_FLR_6 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_2_FLR_6 | 39.02 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
9 | ROOM_3_MULT9_FLR_6 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_3_MULT9_FLR_6 | 24.53 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 23.89 | 40.00 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | BASEMENT | Mixing/Well-Stirred |
2 | RETAIL_1_FLR_1 | Mixing/Well-Stirred |
3 | RETAIL_2_FLR_1 | Mixing/Well-Stirred |
4 | MECH_FLR_1 | Mixing/Well-Stirred |
5 | STORAGE_FLR_1 | Mixing/Well-Stirred |
6 | LAUNDRY_FLR_1 | Mixing/Well-Stirred |
7 | CAFE_FLR_1 | Mixing/Well-Stirred |
8 | LOBBY_FLR_1 | Mixing/Well-Stirred |
9 | ROOM_1_FLR_3 | Mixing/Well-Stirred |
10 | ROOM_2_FLR_3 | Mixing/Well-Stirred |
11 | ROOM_3_MULT19_FLR_3 | Mixing/Well-Stirred |
12 | ROOM_4_MULT19_FLR_3 | Mixing/Well-Stirred |
13 | ROOM_5_FLR_3 | Mixing/Well-Stirred |
14 | ROOM_6_FLR_3 | Mixing/Well-Stirred |
15 | CORRIDOR_FLR_3 | Mixing/Well-Stirred |
16 | ROOM_1_FLR_6 | Mixing/Well-Stirred |
17 | ROOM_2_FLR_6 | Mixing/Well-Stirred |
18 | ROOM_3_MULT9_FLR_6 | Mixing/Well-Stirred |
19 | BANQUET_FLR_6 | Mixing/Well-Stirred |
20 | DINING_FLR_6 | Mixing/Well-Stirred |
21 | KITCHEN_FLR_6 | Mixing/Well-Stirred |
22 | CORRIDOR_FLR_6 | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.0000 |
Sizing Factor ID | Value | |
1 | Global | 1.0000 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | BASEMENT | Cooling | 33243.87674 | 33243.87674 | 2.50528 | 2.50528 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 20:50:00 | 28.93750 | 1.44633E-002 | 1978.83018 | 106.49900 | 0.85446 | 0.00000 |
2 | BASEMENT | Heating | 1213.38023 | 1213.38023 | 5.39439E-002 | 0.85446 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | -6.30000 | 2.29779E-003 | 1978.83018 | 106.49900 | 0.85446 | 0.00000 |
3 | RETAIL_1_FLR_1 | Cooling | 4479.28054 | 4479.28054 | 0.33763 | 0.33763 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 34.40000 | 1.44733E-002 | 67.07136 | 10.82900 | 7.92179E-002 | 0.00000 |
4 | RETAIL_1_FLR_1 | Heating | 3226.23308 | 3226.23308 | 0.14342 | 0.14342 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | -6.30000 | 2.29779E-003 | 67.07136 | 10.82900 | 7.92179E-002 | 0.00000 |
5 | RETAIL_2_FLR_1 | Cooling | 3319.04295 | 3319.04295 | 0.25016 | 0.25016 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:40:00 | 32.43667 | 1.44697E-002 | 77.66889 | 12.54000 | 9.17347E-002 | 0.00000 |
6 | RETAIL_2_FLR_1 | Heating | 1072.91956 | 1072.91956 | 4.76979E-002 | 9.17347E-002 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | -6.30000 | 2.29779E-003 | 77.66889 | 12.54000 | 9.17347E-002 | 0.00000 |
7 | MECH_FLR_1 | Cooling | 3499.28514 | 3499.28514 | 0.26369 | 0.26369 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:40:00 | 32.43667 | 1.44697E-002 | 164.24319 | 2.65200 | 0.00000 | 0.00000 |
8 | MECH_FLR_1 | Heating | 2016.33695 | 2016.33695 | 8.96384E-002 | 8.96384E-002 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | -6.30000 | 2.29779E-003 | 164.24319 | 2.65200 | 0.00000 | 0.00000 |
9 | STORAGE_FLR_1 | Cooling | 1745.61772 | 1745.61772 | 0.13154 | 0.13154 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:50:00 | 32.27833 | 1.44694E-002 | 94.75927 | 2.04000 | 5.77652E-002 | 0.00000 |
10 | STORAGE_FLR_1 | Heating | 1206.20336 | 1206.20336 | 5.36231E-002 | 5.77652E-002 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | -6.30000 | 2.29779E-003 | 94.75927 | 2.04000 | 5.77652E-002 | 0.00000 |
11 | LAUNDRY_FLR_1 | Cooling | 45085.12816 | 45085.12816 | 3.39793 | 3.39793 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:30:00 | 34.11500 | 1.44727E-002 | 78.03947 | 8.40000 | 0.00000 | 0.00000 |
12 | LAUNDRY_FLR_1 | Heating | 2651.80022 | 2651.80022 | 0.11788 | 0.11788 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | -6.30000 | 2.29779E-003 | 78.03947 | 8.40000 | 0.00000 | 0.00000 |
13 | CAFE_FLR_1 | Cooling | 19324.80267 | 19324.80267 | 1.45779 | 1.45779 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 34.40000 | 1.44733E-002 | 188.86188 | 142.30000 | 0.67639 | 0.00000 |
14 | CAFE_FLR_1 | Heating | 8095.69615 | 8095.69615 | 0.35989 | 0.67639 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | -6.30000 | 2.29779E-003 | 188.86188 | 142.30000 | 0.67639 | 0.00000 |
15 | LOBBY_FLR_1 | Cooling | 64234.07967 | 64234.07967 | 4.84278 | 4.84278 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:20:00 | 34.40000 | 1.44733E-002 | 1308.18612 | 422.43500 | 1.89399 | 0.00000 |
16 | LOBBY_FLR_1 | Heating | 19168.00527 | 19168.00527 | 0.85214 | 1.89399 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | -6.30000 | 2.29779E-003 | 1308.18612 | 422.43500 | 1.89399 | 0.00000 |
17 | ROOM_1_FLR_3 | Cooling | 10624.12894 | 10624.12894 | 1.07900 | 1.07900 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:10:00 | 32.91167 | 1.44705E-002 | 39.02202 | 1.50000 | 6.17350E-002 | 0.00000 |
18 | ROOM_1_FLR_3 | Heating | 7185.71273 | 7185.71273 | 0.32131 | 0.32131 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | -6.30000 | 2.29779E-003 | 39.02202 | 1.50000 | 6.17350E-002 | 0.00000 |
19 | ROOM_2_FLR_3 | Cooling | 10504.22297 | 10504.22297 | 1.06682 | 1.06682 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:20:00 | 32.75333 | 1.44703E-002 | 39.01745 | 1.50000 | 6.17278E-002 | 0.00000 |
20 | ROOM_2_FLR_3 | Heating | 7198.09583 | 7198.09583 | 0.32186 | 0.32186 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | -6.30000 | 2.29779E-003 | 39.01745 | 1.50000 | 6.17278E-002 | 0.00000 |
21 | ROOM_3_MULT19_FLR_3 | Cooling | 65801.40601 | 65801.40601 | 6.68209 | 6.68209 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:20:00 | 34.40000 | 1.44733E-002 | 24.52384 | 1.50000 | 0.83707 | 0.00000 |
22 | ROOM_3_MULT19_FLR_3 | Heating | 40941.37347 | 40941.37347 | 1.83076 | 1.83076 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | -6.30000 | 2.29779E-003 | 24.52384 | 1.50000 | 0.83707 | 0.00000 |
23 | ROOM_4_MULT19_FLR_3 | Cooling | 69162.53990 | 69162.53990 | 7.02394 | 7.02394 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 | 34.02000 | 1.44726E-002 | 24.53055 | 1.50000 | 0.83730 | 0.00000 |
24 | ROOM_4_MULT19_FLR_3 | Heating | 41191.01468 | 41191.01468 | 1.84193 | 1.84193 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | -6.30000 | 2.29779E-003 | 24.53055 | 1.50000 | 0.83730 | 0.00000 |
25 | ROOM_5_FLR_3 | Cooling | 9572.00699 | 9572.00699 | 0.97214 | 0.97214 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:40:00 | 31.74000 | 1.44684E-002 | 39.02202 | 1.50000 | 6.17350E-002 | 0.00000 |
26 | ROOM_5_FLR_3 | Heating | 7160.13819 | 7160.13819 | 0.32016 | 0.32016 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | -6.30000 | 2.29779E-003 | 39.02202 | 1.50000 | 6.17350E-002 | 0.00000 |
27 | ROOM_6_FLR_3 | Cooling | 9484.39897 | 9484.39897 | 0.96325 | 0.96325 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:20:00 | 31.26500 | 1.44675E-002 | 39.01745 | 1.50000 | 6.17278E-002 | 0.00000 |
28 | ROOM_6_FLR_3 | Heating | 7172.52977 | 7172.52977 | 0.32072 | 0.32072 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | -6.30000 | 2.29779E-003 | 39.01745 | 1.50000 | 6.17278E-002 | 0.00000 |
29 | CORRIDOR_FLR_3 | Cooling | 15430.53424 | 15430.53424 | 1.16285 | 1.16285 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | 34.30500 | 1.44731E-002 | 389.40468 | 20.95700 | 0.47476 | 0.00000 |
30 | CORRIDOR_FLR_3 | Heating | 11023.74078 | 11023.74078 | 0.49008 | 0.49008 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | -6.30000 | 2.29779E-003 | 389.40468 | 20.95700 | 0.47476 | 0.00000 |
31 | ROOM_1_FLR_6 | Cooling | 2850.61180 | 2850.61180 | 0.28951 | 0.28951 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 33.07000 | 1.44708E-002 | 39.02202 | 1.50000 | 1.54338E-002 | 0.00000 |
32 | ROOM_1_FLR_6 | Heating | 2207.14508 | 2207.14508 | 9.86913E-002 | 9.86913E-002 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | -6.30000 | 2.29779E-003 | 39.02202 | 1.50000 | 1.54338E-002 | 0.00000 |
33 | ROOM_2_FLR_6 | Cooling | 2815.14030 | 2815.14030 | 0.28591 | 0.28591 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:10:00 | 32.91167 | 1.44705E-002 | 39.01745 | 1.50000 | 1.54319E-002 | 0.00000 |
34 | ROOM_2_FLR_6 | Heating | 2212.09186 | 2212.09186 | 9.89125E-002 | 9.89125E-002 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | -6.30000 | 2.29779E-003 | 39.01745 | 1.50000 | 1.54319E-002 | 0.00000 |
35 | ROOM_3_MULT9_FLR_6 | Cooling | 13060.72653 | 13060.72653 | 1.32646 | 1.32646 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 34.40000 | 1.44733E-002 | 24.53055 | 1.50000 | 9.91540E-002 | 0.00000 |
36 | ROOM_3_MULT9_FLR_6 | Heating | 10571.59896 | 10571.59896 | 0.47271 | 0.47271 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | -6.30000 | 2.29779E-003 | 24.53055 | 1.50000 | 9.91540E-002 | 0.00000 |
37 | BANQUET_FLR_6 | Cooling | 30827.15591 | 30827.15591 | 2.32604 | 2.32604 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 34.40000 | 1.44733E-002 | 331.65745 | 249.89600 | 1.18780 | 0.00000 |
38 | BANQUET_FLR_6 | Heating | 7303.67878 | 7303.67878 | 0.32469 | 1.18780 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | -6.30000 | 2.29779E-003 | 331.65745 | 249.89600 | 1.18780 | 0.00000 |
39 | DINING_FLR_6 | Cooling | 32340.88663 | 32340.88663 | 2.44022 | 2.44022 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 34.40000 | 1.44733E-002 | 331.65745 | 249.89600 | 1.18780 | 0.00000 |
40 | DINING_FLR_6 | Heating | 7438.79459 | 7438.79459 | 0.33070 | 1.18780 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 11:50:00 | -6.30000 | 2.29779E-003 | 331.65745 | 249.89600 | 1.18780 | 0.00000 |
41 | KITCHEN_FLR_6 | Cooling | 31219.15178 | 31219.15178 | 2.35901 | 2.35901 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 12:30:00 | 33.54500 | 1.44717E-002 | 103.30446 | 22.23800 | 0.36735 | 0.00000 |
42 | KITCHEN_FLR_6 | Heating | 2312.24309 | 2312.24309 | 0.10278 | 0.36735 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 23:30:00 | -6.30000 | 2.29779E-003 | 103.30446 | 22.23800 | 0.36735 | 0.00000 |
43 | CORRIDOR_FLR_6 | Cooling | 9526.60291 | 9526.60291 | 0.71793 | 0.71793 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | 34.40000 | 1.44733E-002 | 412.12471 | 22.18000 | 0.12562 | 0.00000 |
44 | CORRIDOR_FLR_6 | Heating | 7649.99553 | 7649.99553 | 0.34009 | 0.34009 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 11:50:00 | -6.30000 | 2.29779E-003 | 412.12471 | 22.18000 | 0.12562 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | VAV WITH REHEAT | Cooling | Sensible | 556386.04 | 22.07975 | 22.07975 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 00:00:00 |
2 | VAV WITH REHEAT | Heating | Sensible | 201197.69 | 7.49837 | 7.49837 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 |
3 | FLR_3_DOAS | Cooling | Sensible | 51689.19 | 19.09903 | 2.05125 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 00:00:00 |
4 | FLR_3_DOAS | Heating | Sensible | 55039.41 | 5.62705 | 2.05125 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 2.50528 |
2 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.60188 |
3 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.99500 |
4 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 2.49275 |
5 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
6 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
7 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 6.33020E-004 |
8 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.21614E-004 |
9 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 2.49275 |
10 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
11 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
12 | Coil:Heating:Water | BASEMENT VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 13901.19707 |
13 | Coil:Heating:Water | BASEMENT VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.21614E-004 |
14 | Coil:Heating:Water | BASEMENT VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 291.32737 |
15 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.33763 |
16 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.15137 |
17 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.99500 |
18 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.33594 |
19 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.99500 |
20 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
21 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.51694E-003 |
22 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 4.31630E-005 |
23 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.33594 |
24 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
25 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
26 | Coil:Heating:Water | RETAIL_1_FLR_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 4933.79773 |
27 | Coil:Heating:Water | RETAIL_1_FLR_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 4.31630E-005 |
28 | Coil:Heating:Water | RETAIL_1_FLR_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 114.16075 |
29 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.25016 |
30 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.23658 |
31 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.99500 |
32 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.24891 |
33 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.99500 |
34 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
35 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.61044E-003 |
36 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 2.04549E-005 |
37 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.24891 |
38 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
39 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
40 | Coil:Heating:Water | RETAIL_2_FLR_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 2338.12445 |
41 | Coil:Heating:Water | RETAIL_2_FLR_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.04549E-005 |
42 | Coil:Heating:Water | RETAIL_2_FLR_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 51.00339 |
43 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.26369 |
44 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.47462 |
45 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.99500 |
46 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.26237 |
47 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
48 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
49 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 8.02750E-004 |
50 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 2.93034E-005 |
51 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.26237 |
52 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
53 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
54 | Coil:Heating:Water | MECH_FLR_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 3349.55568 |
55 | Coil:Heating:Water | MECH_FLR_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.93034E-005 |
56 | Coil:Heating:Water | MECH_FLR_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 75.82252 |
57 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.13154 |
58 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.54892 |
59 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.99500 |
60 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.13089 |
61 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
62 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
63 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 6.94095E-004 |
64 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.63711E-005 |
65 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.13089 |
66 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
67 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
68 | Coil:Heating:Water | STORAGE_FLR_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 1871.31825 |
69 | Coil:Heating:Water | STORAGE_FLR_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.63711E-005 |
70 | Coil:Heating:Water | STORAGE_FLR_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 43.10534 |
71 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 3.39793 |
72 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 6.94463E-002 |
73 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.99500 |
74 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 3.38094 |
75 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.99500 |
76 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
77 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.17706E-002 |
78 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.73461E-004 |
79 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 3.38094 |
80 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
81 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
82 | Coil:Heating:Water | LAUNDRY_FLR_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 19827.68395 |
83 | Coil:Heating:Water | LAUNDRY_FLR_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.73461E-004 |
84 | Coil:Heating:Water | LAUNDRY_FLR_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 416.75778 |
85 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 1.45779 |
86 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 9.87196E-002 |
87 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.99500 |
88 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 1.45050 |
89 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.99500 |
90 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
91 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.85942E-003 |
92 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.35337E-004 |
93 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.45050 |
94 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
95 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
96 | Coil:Heating:Water | CAFE_FLR_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 15469.86613 |
97 | Coil:Heating:Water | CAFE_FLR_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.35337E-004 |
98 | Coil:Heating:Water | CAFE_FLR_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 342.11146 |
99 | Fan:ZoneExhaust | LOBBY_FLR_1 EXHAUST FAN | User-Specified Maximum Flow Rate [m3/s] | 0.00000 |
100 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 4.84278 |
101 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.20584 |
102 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.99500 |
103 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 4.81857 |
104 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.99500 |
105 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
106 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.85095E-003 |
107 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 3.81984E-004 |
108 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 4.81857 |
109 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
110 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
111 | Coil:Heating:Water | LOBBY_FLR_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 43663.11800 |
112 | Coil:Heating:Water | LOBBY_FLR_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 3.81984E-004 |
113 | Coil:Heating:Water | LOBBY_FLR_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 949.06780 |
114 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ROOM_1_FLR_3 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 6.17350E-002 |
115 | ZoneHVAC:FourPipeFanCoil | ROOM_1_FLR_3 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 1.07900 |
116 | Fan:OnOff | ROOM_1_FLR_3 FAN COIL FAN COILFAN_FAN | Design Size Maximum Flow Rate [m3/s] | 1.07900 |
117 | ZoneHVAC:FourPipeFanCoil | ROOM_1_FLR_3 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 6.28623E-005 |
118 | ZoneHVAC:FourPipeFanCoil | ROOM_1_FLR_3 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 4.75727E-004 |
119 | Coil:Cooling:Water | ROOM_1_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Air Temperature [C] | 22.53772 |
120 | Coil:Cooling:Water | ROOM_1_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
121 | Coil:Cooling:Water | ROOM_1_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.77288E-003 |
122 | Coil:Cooling:Water | ROOM_1_FLR_3 FAN COIL COOLING COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
123 | Coil:Cooling:Water | ROOM_1_FLR_3 FAN COIL COOLING COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
124 | Coil:Cooling:Water | ROOM_1_FLR_3 FAN COIL COOLING COIL | Design Size Design Water Flow Rate [m3/s] | 4.75727E-004 |
125 | Coil:Cooling:Water | ROOM_1_FLR_3 FAN COIL COOLING COIL | Design Size Design Air Flow Rate [m3/s] | 1.07900 |
126 | Coil:Heating:Water | ROOM_1_FLR_3 FAN COIL HEATING COIL | Design Size Rated Capacity [W] | 7185.54626 |
127 | Coil:Heating:Water | ROOM_1_FLR_3 FAN COIL HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 6.28623E-005 |
128 | Coil:Heating:Water | ROOM_1_FLR_3 FAN COIL HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 205.36487 |
129 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ROOM_2_FLR_3 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 6.17278E-002 |
130 | ZoneHVAC:FourPipeFanCoil | ROOM_2_FLR_3 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 1.06682 |
131 | Fan:OnOff | ROOM_2_FLR_3 FAN COIL FAN COILFAN_FAN | Design Size Maximum Flow Rate [m3/s] | 1.06682 |
132 | ZoneHVAC:FourPipeFanCoil | ROOM_2_FLR_3 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 6.29706E-005 |
133 | ZoneHVAC:FourPipeFanCoil | ROOM_2_FLR_3 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 4.70750E-004 |
134 | Coil:Cooling:Water | ROOM_2_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Air Temperature [C] | 22.53771 |
135 | Coil:Cooling:Water | ROOM_2_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
136 | Coil:Cooling:Water | ROOM_2_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.77637E-003 |
137 | Coil:Cooling:Water | ROOM_2_FLR_3 FAN COIL COOLING COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
138 | Coil:Cooling:Water | ROOM_2_FLR_3 FAN COIL COOLING COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
139 | Coil:Cooling:Water | ROOM_2_FLR_3 FAN COIL COOLING COIL | Design Size Design Water Flow Rate [m3/s] | 4.70750E-004 |
140 | Coil:Cooling:Water | ROOM_2_FLR_3 FAN COIL COOLING COIL | Design Size Design Air Flow Rate [m3/s] | 1.06682 |
141 | Coil:Heating:Water | ROOM_2_FLR_3 FAN COIL HEATING COIL | Design Size Rated Capacity [W] | 7197.92907 |
142 | Coil:Heating:Water | ROOM_2_FLR_3 FAN COIL HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 6.29706E-005 |
143 | Coil:Heating:Water | ROOM_2_FLR_3 FAN COIL HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 205.71864 |
144 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ROOM_3_MULT19_FLR_3 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.83707 |
145 | ZoneHVAC:FourPipeFanCoil | ROOM_3_MULT19_FLR_3 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 6.68209 |
146 | Fan:OnOff | ROOM_3_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN | Design Size Maximum Flow Rate [m3/s] | 6.68209 |
147 | ZoneHVAC:FourPipeFanCoil | ROOM_3_MULT19_FLR_3 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 3.58169E-004 |
148 | ZoneHVAC:FourPipeFanCoil | ROOM_3_MULT19_FLR_3 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 2.87774E-003 |
149 | Coil:Cooling:Water | ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Air Temperature [C] | 22.53890 |
150 | Coil:Cooling:Water | ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
151 | Coil:Cooling:Water | ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.67536E-003 |
152 | Coil:Cooling:Water | ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
153 | Coil:Cooling:Water | ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
154 | Coil:Cooling:Water | ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Water Flow Rate [m3/s] | 2.87774E-003 |
155 | Coil:Cooling:Water | ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Air Flow Rate [m3/s] | 6.68209 |
156 | Coil:Heating:Water | ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL | Design Size Rated Capacity [W] | 40940.91685 |
157 | Coil:Heating:Water | ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 3.58169E-004 |
158 | Coil:Heating:Water | ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 1170.08260 |
159 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ROOM_4_MULT19_FLR_3 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.83730 |
160 | ZoneHVAC:FourPipeFanCoil | ROOM_4_MULT19_FLR_3 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 7.02394 |
161 | Fan:OnOff | ROOM_4_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN | Design Size Maximum Flow Rate [m3/s] | 7.02394 |
162 | ZoneHVAC:FourPipeFanCoil | ROOM_4_MULT19_FLR_3 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 3.60353E-004 |
163 | ZoneHVAC:FourPipeFanCoil | ROOM_4_MULT19_FLR_3 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 3.16831E-003 |
164 | Coil:Cooling:Water | ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Air Temperature [C] | 22.53777 |
165 | Coil:Cooling:Water | ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
166 | Coil:Cooling:Water | ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.86935E-003 |
167 | Coil:Cooling:Water | ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
168 | Coil:Cooling:Water | ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
169 | Coil:Cooling:Water | ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Water Flow Rate [m3/s] | 3.16831E-003 |
170 | Coil:Cooling:Water | ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | Design Size Design Air Flow Rate [m3/s] | 7.02394 |
171 | Coil:Heating:Water | ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL | Design Size Rated Capacity [W] | 41190.55538 |
172 | Coil:Heating:Water | ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 3.60353E-004 |
173 | Coil:Heating:Water | ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 1177.21489 |
174 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ROOM_5_FLR_3 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 6.17350E-002 |
175 | ZoneHVAC:FourPipeFanCoil | ROOM_5_FLR_3 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 0.97214 |
176 | Fan:OnOff | ROOM_5_FLR_3 FAN COIL FAN COILFAN_FAN | Design Size Maximum Flow Rate [m3/s] | 0.97214 |
177 | ZoneHVAC:FourPipeFanCoil | ROOM_5_FLR_3 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 6.26386E-005 |
178 | ZoneHVAC:FourPipeFanCoil | ROOM_5_FLR_3 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 4.31725E-004 |
179 | Coil:Cooling:Water | ROOM_5_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Air Temperature [C] | 22.53761 |
180 | Coil:Cooling:Water | ROOM_5_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
181 | Coil:Cooling:Water | ROOM_5_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.80325E-003 |
182 | Coil:Cooling:Water | ROOM_5_FLR_3 FAN COIL COOLING COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
183 | Coil:Cooling:Water | ROOM_5_FLR_3 FAN COIL COOLING COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
184 | Coil:Cooling:Water | ROOM_5_FLR_3 FAN COIL COOLING COIL | Design Size Design Water Flow Rate [m3/s] | 4.31725E-004 |
185 | Coil:Cooling:Water | ROOM_5_FLR_3 FAN COIL COOLING COIL | Design Size Design Air Flow Rate [m3/s] | 0.97214 |
186 | Coil:Heating:Water | ROOM_5_FLR_3 FAN COIL HEATING COIL | Design Size Rated Capacity [W] | 7159.97230 |
187 | Coil:Heating:Water | ROOM_5_FLR_3 FAN COIL HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 6.26386E-005 |
188 | Coil:Heating:Water | ROOM_5_FLR_3 FAN COIL HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 204.63423 |
189 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ROOM_6_FLR_3 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 6.17278E-002 |
190 | ZoneHVAC:FourPipeFanCoil | ROOM_6_FLR_3 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 0.96325 |
191 | Fan:OnOff | ROOM_6_FLR_3 FAN COIL FAN COILFAN_FAN | Design Size Maximum Flow Rate [m3/s] | 0.96325 |
192 | ZoneHVAC:FourPipeFanCoil | ROOM_6_FLR_3 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 6.27470E-005 |
193 | ZoneHVAC:FourPipeFanCoil | ROOM_6_FLR_3 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 4.28049E-004 |
194 | Coil:Cooling:Water | ROOM_6_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Air Temperature [C] | 22.53760 |
195 | Coil:Cooling:Water | ROOM_6_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
196 | Coil:Cooling:Water | ROOM_6_FLR_3 FAN COIL COOLING COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.80596E-003 |
197 | Coil:Cooling:Water | ROOM_6_FLR_3 FAN COIL COOLING COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
198 | Coil:Cooling:Water | ROOM_6_FLR_3 FAN COIL COOLING COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
199 | Coil:Cooling:Water | ROOM_6_FLR_3 FAN COIL COOLING COIL | Design Size Design Water Flow Rate [m3/s] | 4.28049E-004 |
200 | Coil:Cooling:Water | ROOM_6_FLR_3 FAN COIL COOLING COIL | Design Size Design Air Flow Rate [m3/s] | 0.96325 |
201 | Coil:Heating:Water | ROOM_6_FLR_3 FAN COIL HEATING COIL | Design Size Rated Capacity [W] | 7172.36359 |
202 | Coil:Heating:Water | ROOM_6_FLR_3 FAN COIL HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 6.27470E-005 |
203 | Coil:Heating:Water | ROOM_6_FLR_3 FAN COIL HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 204.98824 |
204 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 1.16285 |
205 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 1.00000 |
206 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.99500 |
207 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 1.15703 |
208 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
209 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
210 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.73278E-004 |
211 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.47913E-004 |
212 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.15703 |
213 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
214 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
215 | Coil:Heating:Water | CORRIDOR_FLR_3 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 16907.37262 |
216 | Coil:Heating:Water | CORRIDOR_FLR_3 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.47913E-004 |
217 | Coil:Heating:Water | CORRIDOR_FLR_3 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 390.87720 |
218 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ROOM_1_FLR_6 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.54338E-002 |
219 | ZoneHVAC:FourPipeFanCoil | ROOM_1_FLR_6 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 0.28951 |
220 | Fan:OnOff | ROOM_1_FLR_6 FAN COIL FAN COILFAN_FAN | Design Size Maximum Flow Rate [m3/s] | 0.28951 |
221 | ZoneHVAC:FourPipeFanCoil | ROOM_1_FLR_6 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 1.93086E-005 |
222 | ZoneHVAC:FourPipeFanCoil | ROOM_1_FLR_6 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 1.27088E-004 |
223 | Coil:Cooling:Water | ROOM_1_FLR_6 FAN COIL COOLING COIL | Design Size Design Inlet Air Temperature [C] | 22.53777 |
224 | Coil:Cooling:Water | ROOM_1_FLR_6 FAN COIL COOLING COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
225 | Coil:Cooling:Water | ROOM_1_FLR_6 FAN COIL COOLING COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.75462E-003 |
226 | Coil:Cooling:Water | ROOM_1_FLR_6 FAN COIL COOLING COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
227 | Coil:Cooling:Water | ROOM_1_FLR_6 FAN COIL COOLING COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
228 | Coil:Cooling:Water | ROOM_1_FLR_6 FAN COIL COOLING COIL | Design Size Design Water Flow Rate [m3/s] | 1.27088E-004 |
229 | Coil:Cooling:Water | ROOM_1_FLR_6 FAN COIL COOLING COIL | Design Size Design Air Flow Rate [m3/s] | 0.28951 |
230 | Coil:Heating:Water | ROOM_1_FLR_6 FAN COIL HEATING COIL | Design Size Rated Capacity [W] | 2207.09528 |
231 | Coil:Heating:Water | ROOM_1_FLR_6 FAN COIL HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.93086E-005 |
232 | Coil:Heating:Water | ROOM_1_FLR_6 FAN COIL HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 63.07505 |
233 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ROOM_2_FLR_6 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.54319E-002 |
234 | ZoneHVAC:FourPipeFanCoil | ROOM_2_FLR_6 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 0.28591 |
235 | Fan:OnOff | ROOM_2_FLR_6 FAN COIL FAN COILFAN_FAN | Design Size Maximum Flow Rate [m3/s] | 0.28591 |
236 | ZoneHVAC:FourPipeFanCoil | ROOM_2_FLR_6 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 1.93519E-005 |
237 | ZoneHVAC:FourPipeFanCoil | ROOM_2_FLR_6 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 1.25610E-004 |
238 | Coil:Cooling:Water | ROOM_2_FLR_6 FAN COIL COOLING COIL | Design Size Design Inlet Air Temperature [C] | 22.53777 |
239 | Coil:Cooling:Water | ROOM_2_FLR_6 FAN COIL COOLING COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
240 | Coil:Cooling:Water | ROOM_2_FLR_6 FAN COIL COOLING COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.75807E-003 |
241 | Coil:Cooling:Water | ROOM_2_FLR_6 FAN COIL COOLING COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
242 | Coil:Cooling:Water | ROOM_2_FLR_6 FAN COIL COOLING COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
243 | Coil:Cooling:Water | ROOM_2_FLR_6 FAN COIL COOLING COIL | Design Size Design Water Flow Rate [m3/s] | 1.25610E-004 |
244 | Coil:Cooling:Water | ROOM_2_FLR_6 FAN COIL COOLING COIL | Design Size Design Air Flow Rate [m3/s] | 0.28591 |
245 | Coil:Heating:Water | ROOM_2_FLR_6 FAN COIL HEATING COIL | Design Size Rated Capacity [W] | 2212.04194 |
246 | Coil:Heating:Water | ROOM_2_FLR_6 FAN COIL HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.93519E-005 |
247 | Coil:Heating:Water | ROOM_2_FLR_6 FAN COIL HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 63.21637 |
248 | AirTerminal:SingleDuct:ConstantVolume:NoReheat | ROOM_3_MULT9_FLR_6 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 9.91540E-002 |
249 | ZoneHVAC:FourPipeFanCoil | ROOM_3_MULT9_FLR_6 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 1.32646 |
250 | Fan:OnOff | ROOM_3_MULT9_FLR_6 FAN COIL FAN COILFAN_FAN | Design Size Maximum Flow Rate [m3/s] | 1.32646 |
251 | ZoneHVAC:FourPipeFanCoil | ROOM_3_MULT9_FLR_6 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 9.24833E-005 |
252 | ZoneHVAC:FourPipeFanCoil | ROOM_3_MULT9_FLR_6 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 5.91060E-004 |
253 | Coil:Cooling:Water | ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL | Design Size Design Inlet Air Temperature [C] | 22.53759 |
254 | Coil:Cooling:Water | ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
255 | Coil:Cooling:Water | ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.81745E-003 |
256 | Coil:Cooling:Water | ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
257 | Coil:Cooling:Water | ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
258 | Coil:Cooling:Water | ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL | Design Size Design Water Flow Rate [m3/s] | 5.91060E-004 |
259 | Coil:Cooling:Water | ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL | Design Size Design Air Flow Rate [m3/s] | 1.32646 |
260 | Coil:Heating:Water | ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL | Design Size Rated Capacity [W] | 10571.40900 |
261 | Coil:Heating:Water | ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 9.24833E-005 |
262 | Coil:Heating:Water | ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 302.11026 |
263 | Fan:ZoneExhaust | BANQUET_FLR_6 EXHAUST FAN | User-Specified Maximum Flow Rate [m3/s] | 0.00000 |
264 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 2.32604 |
265 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.10865 |
266 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.99500 |
267 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 2.31441 |
268 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.99500 |
269 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
270 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.50670E-003 |
271 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.66873E-004 |
272 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 2.31441 |
273 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
274 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
275 | Coil:Heating:Water | BANQUET_FLR_6 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 19074.63704 |
276 | Coil:Heating:Water | BANQUET_FLR_6 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.66873E-004 |
277 | Coil:Heating:Water | BANQUET_FLR_6 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 411.00171 |
278 | Fan:ZoneExhaust | DINING_FLR_6 EXHAUST FAN | User-Specified Maximum Flow Rate [m3/s] | 0.00000 |
279 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 2.44022 |
280 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.10357 |
281 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.99500 |
282 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 2.42802 |
283 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.99500 |
284 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
285 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.67883E-003 |
286 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.73112E-004 |
287 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 2.42802 |
288 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
289 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
290 | Coil:Heating:Water | DINING_FLR_6 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 19787.80721 |
291 | Coil:Heating:Water | DINING_FLR_6 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.73112E-004 |
292 | Coil:Heating:Water | DINING_FLR_6 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 425.95341 |
293 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 2.35901 |
294 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.80025 |
295 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.99500 |
296 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 2.34721 |
297 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.99500 |
298 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
299 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.14177E-002 |
300 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.24342E-004 |
301 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 2.34721 |
302 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
303 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
304 | Coil:Heating:Water | KITCHEN_FLR_6 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 14213.11108 |
305 | Coil:Heating:Water | KITCHEN_FLR_6 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.24342E-004 |
306 | Coil:Heating:Water | KITCHEN_FLR_6 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 299.33219 |
307 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.71793 |
308 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.43742 |
309 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.99500 |
310 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.71434 |
311 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
312 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
313 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 8.71007E-004 |
314 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 9.87143E-005 |
315 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.71434 |
316 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
317 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
318 | Coil:Heating:Water | CORRIDOR_FLR_6 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 11283.65334 |
319 | Coil:Heating:Water | CORRIDOR_FLR_6 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 9.87143E-005 |
320 | Coil:Heating:Water | CORRIDOR_FLR_6 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 264.49101 |
321 | AirLoopHVAC | VAV WITH REHEAT | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 22.08190 |
322 | AirLoopHVAC | VAV WITH REHEAT | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 22.08190 |
323 | AirLoopHVAC | VAV WITH REHEAT | Sum of Air Terminal Maximum Flow Rates [m3/s] | 22.19286 |
324 | AirLoopHVAC | VAV WITH REHEAT | Adjusted Heating Design Air Flow Rate [m3/s] | 22.08190 |
325 | AirLoopHVAC | VAV WITH REHEAT | Adjusted Cooling Design Air Flow Rate [m3/s] | 22.08190 |
326 | AirLoopHVAC | VAV WITH REHEAT | Adjusted Main Design Air Flow Rate [m3/s] | 22.08190 |
327 | AirLoopHVAC | VAV WITH REHEAT | User Heating Air Flow Ratio [] | 0.30000 |
328 | AirLoopHVAC | VAV WITH REHEAT | Calculated Heating Air Flow Ratio [] | 1.00000 |
329 | AirLoopHVAC | FLR_3_DOAS | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.05132 |
330 | AirLoopHVAC | FLR_3_DOAS | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 2.05132 |
331 | AirLoopHVAC | FLR_3_DOAS | Sum of Air Terminal Maximum Flow Rates [m3/s] | 2.05132 |
332 | AirLoopHVAC | FLR_3_DOAS | Adjusted Heating Design Air Flow Rate [m3/s] | 2.05132 |
333 | AirLoopHVAC | FLR_3_DOAS | Adjusted Cooling Design Air Flow Rate [m3/s] | 2.05132 |
334 | AirLoopHVAC | FLR_3_DOAS | Adjusted Main Design Air Flow Rate [m3/s] | 2.05132 |
335 | AirLoopHVAC | FLR_3_DOAS | User Heating Air Flow Ratio [] | 0.30000 |
336 | AirLoopHVAC | FLR_3_DOAS | Calculated Heating Air Flow Ratio [] | 1.00000 |
337 | AirLoopHVAC | VAV WITH REHEAT | Design Supply Air Flow Rate [m3/s] | 22.08190 |
338 | AirLoopHVAC | FLR_3_DOAS | Design Supply Air Flow Rate [m3/s] | 2.05132 |
339 | Controller:OutdoorAir | VAV WITH REHEAT_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 22.08190 |
340 | Controller:OutdoorAir | VAV WITH REHEAT_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 22.07975 |
341 | HeatExchanger:AirToAir:SensibleAndLatent | VAV WITH REHEAT OA HEAT RECOVERY | Design Size Nominal Supply Air Flow Rate [m3/s] | 22.07975 |
342 | Coil:Cooling:Water | VAV WITH REHEAT COOLING COIL | Design Size Design Inlet Air Temperature [C] | 34.40000 |
343 | Coil:Cooling:Water | VAV WITH REHEAT COOLING COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
344 | Coil:Cooling:Water | VAV WITH REHEAT COOLING COIL | Design Size Design Outlet Air Temperature [C] | 10.92942 |
345 | Coil:Cooling:Water | VAV WITH REHEAT COOLING COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 1.44733E-002 |
346 | Coil:Cooling:Water | VAV WITH REHEAT COOLING COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
347 | Coil:Cooling:Water | VAV WITH REHEAT COOLING COIL | Design Size Design Coil Load [W] | 1006896.45191 |
348 | Coil:Cooling:Water | VAV WITH REHEAT COOLING COIL | Design Size Design Water Flow Rate [m3/s] | 3.59640E-002 |
349 | Coil:Cooling:Water | VAV WITH REHEAT COOLING COIL | Design Size Design Air Flow Rate [m3/s] | 22.08190 |
350 | Coil:Heating:Water | VAV WITH REHEAT HEATING COIL | Design Size Rated Capacity [W] | 177751.76314 |
351 | Coil:Heating:Water | VAV WITH REHEAT HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.55505E-003 |
352 | Coil:Heating:Water | VAV WITH REHEAT HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 3000.09492 |
353 | Fan:VariableVolume | VAV WITH REHEAT FAN | Design Size Maximum Flow Rate [m3/s] | 22.08190 |
354 | Controller:WaterCoil | VAV WITH REHEAT_COOLC_CONTROLLER | Maximum Actuated Flow [m3/s] | 3.59640E-002 |
355 | Controller:WaterCoil | VAV WITH REHEAT_COOLC_CONTROLLER | Controller Convergence Tolerance | 1.32408E-005 |
356 | Controller:WaterCoil | VAV WITH REHEAT_HEATC_CONTROLLER | Maximum Actuated Flow [m3/s] | 1.55505E-003 |
357 | Controller:OutdoorAir | FLR_3_DOAS_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 2.05132 |
358 | Controller:OutdoorAir | FLR_3_DOAS_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.05125 |
359 | HeatExchanger:AirToAir:SensibleAndLatent | FLR_3_DOAS OA HEAT RECOVERY | Design Size Nominal Supply Air Flow Rate [m3/s] | 2.05125 |
360 | Coil:Cooling:Water | FLR_3_DOAS COOLING COIL | Design Size Design Inlet Air Temperature [C] | 34.40000 |
361 | Coil:Cooling:Water | FLR_3_DOAS COOLING COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
362 | Coil:Cooling:Water | FLR_3_DOAS COOLING COIL | Design Size Design Outlet Air Temperature [C] | 11.90668 |
363 | Coil:Cooling:Water | FLR_3_DOAS COOLING COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 1.44733E-002 |
364 | Coil:Cooling:Water | FLR_3_DOAS COOLING COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
365 | Coil:Cooling:Water | FLR_3_DOAS COOLING COIL | Design Size Design Coil Load [W] | 91161.10877 |
366 | Coil:Cooling:Water | FLR_3_DOAS COOLING COIL | Design Size Design Water Flow Rate [m3/s] | 3.25606E-003 |
367 | Coil:Cooling:Water | FLR_3_DOAS COOLING COIL | Design Size Design Air Flow Rate [m3/s] | 2.05132 |
368 | Coil:Heating:Water | FLR_3_DOAS HEATING COIL | Design Size Rated Capacity [W] | 16512.40431 |
369 | Coil:Heating:Water | FLR_3_DOAS HEATING COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.44458E-004 |
370 | Coil:Heating:Water | FLR_3_DOAS HEATING COIL | Design Size U-Factor Times Area Value [W/K] | 278.69642 |
371 | Fan:ConstantVolume | FLR_3_DOAS FAN | User-Specified Maximum Flow Rate [m3/s] | 2.05125 |
372 | Controller:WaterCoil | FLR_3_DOAS_COOLC_CONTROLLER | Maximum Actuated Flow [m3/s] | 3.25606E-003 |
373 | Controller:WaterCoil | FLR_3_DOAS_COOLC_CONTROLLER | Controller Convergence Tolerance | 1.46247E-004 |
374 | Controller:WaterCoil | FLR_3_DOAS_HEATC_CONTROLLER | Maximum Actuated Flow [m3/s] | 1.44458E-004 |
375 | Pump:VariableSpeed | COOLSYS1 PUMP SECONDARY | Design Flow Rate [m3/s] | 4.79161E-002 |
376 | Pump:VariableSpeed | COOLSYS1 PUMP SECONDARY | Design Power Consumption [W] | 9873.73799 |
377 | PlantLoop | HEATSYS1 | Maximum Loop Flow Rate [m3/s] | 4.43304E-003 |
378 | PlantLoop | HEATSYS1 | Plant Loop Volume [m3] | 0.53196 |
379 | Pump:VariableSpeed | HEATSYS1 PUMP | Design Flow Rate [m3/s] | 4.43304E-003 |
380 | Pump:VariableSpeed | HEATSYS1 PUMP | Design Power Consumption [W] | 1335.03575 |
381 | Pump:VariableSpeed | HEATSYS1 PUMP | Design Minimum Flow Rate [m3/s] | 0.00000 |
382 | Boiler:HotWater | HEATSYS1 BOILER | Design Size Nominal Capacity [W] | 506723.23966 |
383 | Boiler:HotWater | HEATSYS1 BOILER | User-Specified Nominal Capacity [W] | 506723.24000 |
384 | Boiler:HotWater | HEATSYS1 BOILER | Design Size Design Water Flow Rate [m3/s] | 4.43304E-003 |
385 | PlantLoop | COOLSYS1 | Maximum Loop Flow Rate [m3/s] | 4.79161E-002 |
386 | PlantLoop | COOLSYS1 | Plant Loop Volume [m3] | 5.74994 |
387 | Pump:ConstantSpeed | COOLSYS1 PUMP | Design Flow Rate [m3/s] | 4.79161E-002 |
388 | Pump:ConstantSpeed | COOLSYS1 PUMP | Design Power Consumption [W] | 6835.92183 |
389 | Chiller:Electric:EIR | COOLSYS1 CHILLER1 | Design Size Reference Chilled Water Flow Rate [m3/s] | 4.79161E-002 |
390 | Chiller:Electric:EIR | COOLSYS1 CHILLER1 | Design Size Reference Capacity [W] | 1341523.96542 |
391 | Chiller:Electric:EIR | COOLSYS1 CHILLER1 | User-Specified Reference Capacity [W] | 1342132.77000 |
392 | Chiller:Electric:EIR | COOLSYS1 CHILLER1 | Design Size Reference Condenser Fluid Flow Rate [m3/s] | 153.00314 |
393 | PlantLoop | SWHSYS1 | Maximum Loop Flow Rate [m3/s] | 3.75036E-004 |
394 | PlantLoop | SWHSYS1 | Plant Loop Volume [m3] | 4.50044E-002 |
395 | Pump:ConstantSpeed | SWHSYS1 PUMP | Design Flow Rate [m3/s] | 3.75036E-004 |
396 | Pump:ConstantSpeed | SWHSYS1 PUMP | Design Power Consumption [W] | 47.90688 |
397 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | Use Side Design Flow Rate [m3/s] | 3.75036E-004 |
Component Type | Name | Nominal Total Capacity {W} | |
1 | Coil:Heating:Water | BASEMENT VAV BOX REHEAT COIL | 13972.88 |
2 | Coil:Heating:Water | RETAIL_1_FLR_1 VAV BOX REHEAT COIL | 4956.71 |
3 | Coil:Heating:Water | RETAIL_2_FLR_1 VAV BOX REHEAT COIL | 2349.77 |
4 | Coil:Heating:Water | MECH_FLR_1 VAV BOX REHEAT COIL | 3365.43 |
5 | Coil:Heating:Water | STORAGE_FLR_1 VAV BOX REHEAT COIL | 1880.04 |
6 | Coil:Heating:Water | LAUNDRY_FLR_1 VAV BOX REHEAT COIL | 19929.66 |
7 | Coil:Heating:Water | CAFE_FLR_1 VAV BOX REHEAT COIL | 15544.88 |
8 | Coil:Heating:Water | LOBBY_FLR_1 VAV BOX REHEAT COIL | 43881.28 |
9 | Coil:Heating:Water | ROOM_1_FLR_3 FAN COIL HEATING COIL | 7740.43 |
10 | Coil:Heating:Water | ROOM_2_FLR_3 FAN COIL HEATING COIL | 7753.77 |
11 | Coil:Heating:Water | ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL | 44102.37 |
12 | Coil:Heating:Water | ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL | 44371.24 |
13 | Coil:Heating:Water | ROOM_5_FLR_3 FAN COIL HEATING COIL | 7712.89 |
14 | Coil:Heating:Water | ROOM_6_FLR_3 FAN COIL HEATING COIL | 7726.24 |
15 | Coil:Heating:Water | CORRIDOR_FLR_3 VAV BOX REHEAT COIL | 16985.95 |
16 | Coil:Heating:Water | ROOM_1_FLR_6 FAN COIL HEATING COIL | 2377.44 |
17 | Coil:Heating:Water | ROOM_2_FLR_6 FAN COIL HEATING COIL | 2382.76 |
18 | Coil:Heating:Water | ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL | 11387.27 |
19 | Coil:Heating:Water | BANQUET_FLR_6 VAV BOX REHEAT COIL | 19170.64 |
20 | Coil:Heating:Water | DINING_FLR_6 VAV BOX REHEAT COIL | 19887.48 |
21 | Coil:Heating:Water | KITCHEN_FLR_6 VAV BOX REHEAT COIL | 14286.08 |
22 | Coil:Heating:Water | CORRIDOR_FLR_6 VAV BOX REHEAT COIL | 11335.45 |
23 | Coil:Heating:Water | VAV WITH REHEAT HEATING COIL | 132197.42 |
24 | Coil:Heating:Water | FLR_3_DOAS HEATING COIL | 12280.59 |
Component Type | Name | Nominal Total Capacity {W} | Nominal Sensible Capacity {W} | Nominal Latent Capacity {W} | Nominal Sensible Heat Ratio | Nominal Coil UA Value {W/C} | Nominal Coil Surface Area {m2} | |
1 | Coil:Cooling:Water | ROOM_1_FLR_3 FAN COIL COOLING COIL | 19427.65 | 14980.20 | 4447.45 | 0.77 | 2253.81 | 22.86 |
2 | Coil:Cooling:Water | ROOM_2_FLR_3 FAN COIL COOLING COIL | 19218.33 | 14815.76 | 4402.57 | 0.77 | 2229.37 | 22.61 |
3 | Coil:Cooling:Water | ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | 118565.73 | 91956.04 | 26609.69 | 0.78 | 13783.08 | 139.80 |
4 | Coil:Cooling:Water | ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | 128259.85 | 98350.36 | 29909.49 | 0.77 | 14852.36 | 150.64 |
5 | Coil:Cooling:Water | ROOM_5_FLR_3 FAN COIL COOLING COIL | 17582.20 | 13533.25 | 4048.95 | 0.77 | 2038.50 | 20.68 |
6 | Coil:Cooling:Water | ROOM_6_FLR_3 FAN COIL COOLING COIL | 17428.20 | 13412.61 | 4015.59 | 0.77 | 2020.54 | 20.49 |
7 | Coil:Cooling:Water | ROOM_1_FLR_6 FAN COIL COOLING COIL | 5198.61 | 4012.83 | 1185.78 | 0.77 | 603.32 | 6.12 |
8 | Coil:Cooling:Water | ROOM_2_FLR_6 FAN COIL COOLING COIL | 5136.55 | 3964.13 | 1172.43 | 0.77 | 596.07 | 6.05 |
9 | Coil:Cooling:Water | ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL | 24040.21 | 18488.90 | 5551.32 | 0.77 | 2786.50 | 28.26 |
10 | Coil:Cooling:Water | VAV WITH REHEAT COOLING COIL | 713688.50 | 450069.74 | 263618.77 | 0.63 | 88202.28 | 894.60 |
11 | Coil:Cooling:Water | FLR_3_DOAS COOLING COIL | 64688.92 | 41041.02 | 23647.90 | 0.63 | 7608.06 | 77.17 |
Component Type | Component Name | IPLV in SI Units {W/W} | IPLV in IP Units {Btu/W-h} | |
1 | Chiller:Electric:EIR | COOLSYS1 CHILLER1 | 3.72 | 12.68 |
Zone Name | # Surfaces | |
1 | BASEMENT | 14 |
2 | RETAIL_1_FLR_1 | 8 |
3 | RETAIL_2_FLR_1 | 8 |
4 | MECH_FLR_1 | 7 |
5 | STORAGE_FLR_1 | 8 |
6 | LAUNDRY_FLR_1 | 8 |
7 | CAFE_FLR_1 | 10 |
8 | LOBBY_FLR_1 | 22 |
9 | ROOM_1_FLR_3 | 9 |
10 | ROOM_2_FLR_3 | 9 |
11 | ROOM_3_MULT19_FLR_3 | 8 |
12 | ROOM_4_MULT19_FLR_3 | 8 |
13 | ROOM_5_FLR_3 | 9 |
14 | ROOM_6_FLR_3 | 9 |
15 | CORRIDOR_FLR_3 | 25 |
16 | ROOM_1_FLR_6 | 9 |
17 | ROOM_2_FLR_6 | 9 |
18 | ROOM_3_MULT9_FLR_6 | 8 |
19 | BANQUET_FLR_6 | 8 |
20 | DINING_FLR_6 | 8 |
21 | KITCHEN_FLR_6 | 12 |
22 | CORRIDOR_FLR_6 | 19 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | BASEMENT_WALL_NORTH | Wall | CTF - ConductionTransferFunction | BASEMENT_WALL_NORTH_CFACTOR | 0.940 | 0.824 | 211.13 | 211.13 | 211.13 | 0.00 | 90.00 | 86.56 | 2.44 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | BASEMENT_WALL_EAST | Wall | CTF - ConductionTransferFunction | BASEMENT_WALL_EAST_CFACTOR | 0.940 | 0.824 | 55.76 | 55.76 | 55.76 | 90.00 | 90.00 | 22.86 | 2.44 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
3 | BASEMENT_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | BASEMENT_WALL_SOUTH_CFACTOR | 0.940 | 0.824 | 211.13 | 211.13 | 211.13 | 180.00 | 90.00 | 86.56 | 2.44 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
4 | BASEMENT_WALL_WEST | Wall | CTF - ConductionTransferFunction | BASEMENT_WALL_WEST_CFACTOR | 0.940 | 0.824 | 55.76 | 55.76 | 55.76 | 270.00 | 90.00 | 22.86 | 2.44 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
5 | BASEMENT_FLOOR | Floor | CTF - ConductionTransferFunction | BASEMENT_FLOOR | 2.705 | 1.632 | 1978.83 | 1978.83 | 1978.83 | 0.00 | 180.00 | 86.56 | 22.86 | 0.00 | BASEMENT_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
6 | BASEMENT_CEILING_1 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 67.07 | 67.07 | 67.07 | 180.00 | 0.00 | 11.58 | 5.79 | 0.00 | RETAIL_1_FLR_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
7 | BASEMENT_CEILING_2 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 77.67 | 77.67 | 77.67 | 180.00 | 0.00 | 11.58 | 6.71 | 0.00 | RETAIL_2_FLR_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
8 | BASEMENT_CEILING_3 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 164.24 | 164.24 | 164.24 | 180.00 | 0.00 | 15.85 | 10.36 | 0.00 | MECH_FLR_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
9 | BASEMENT_CEILING_4 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 94.76 | 94.76 | 94.76 | 180.00 | 0.00 | 9.14 | 10.36 | 0.00 | STORAGE_FLR_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
10 | BASEMENT_CEILING_5 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 78.04 | 78.04 | 78.04 | 180.00 | 0.00 | 4.57 | 17.07 | 0.00 | LAUNDRY_FLR_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
11 | BASEMENT_CEILING_6 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 188.86 | 188.86 | 188.86 | 180.00 | 0.00 | 32.61 | 5.79 | 0.00 | CAFE_FLR_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
12 | BASEMENT_CEILING_7 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 1088.56 | 1088.56 | 1088.56 | 180.00 | 0.00 | 32.99 | 32.99 | 0.00 | LOBBY_FLR_1_FLOOR_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 6 | ||
13 | BASEMENT_CEILING_8 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 219.63 | 219.63 | 219.63 | 90.00 | 0.00 | 14.82 | 14.82 | 0.00 | LOBBY_FLR_1_FLOOR_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 6 | ||
14 | BASEMENT_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 3957.66 | 3957.66 | 3957.66 | 0.00 | 90.00 | 3957.66 | 1.00 | 0.00 | BASEMENT_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
15 | RETAIL_1_FLR_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.969 | 0.846 | 22.63 | 45.89 | 22.63 | 180.00 | 90.00 | 11.58 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
16 | RETAIL_1_FLR_1_WALL_SOUTH_WINDOW | Window | RETAIL_1_FLR_1_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 23.26 | 23.26 | 23.26 | 180.00 | 90.00 | 10.92 | 2.13 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
17 | RETAIL_1_FLR_1_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.969 | 0.846 | 22.95 | 22.95 | 22.95 | 270.00 | 90.00 | 5.79 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
18 | RETAIL_1_FLR_1_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 45.89 | 45.89 | 45.89 | 0.00 | 90.00 | 11.58 | 3.96 | 0.00 | RETAIL_2_FLR_1_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
19 | RETAIL_1_FLR_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.95 | 22.95 | 22.95 | 90.00 | 90.00 | 5.79 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_2_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
20 | RETAIL_1_FLR_1_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 67.07 | 67.07 | 67.07 | 0.00 | 180.00 | 11.58 | 5.79 | 0.00 | BASEMENT_CEILING_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
21 | RETAIL_1_FLR_1_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 67.07 | 67.07 | 67.07 | 180.00 | 0.00 | 11.58 | 5.79 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 7.62E-002 | 0.92 | 4 | ||
22 | RETAIL_1_FLR_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 134.14 | 134.14 | 134.14 | 0.00 | 90.00 | 134.14 | 1.00 | 0.00 | RETAIL_1_FLR_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
23 | RETAIL_2_FLR_1_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.969 | 0.846 | 24.62 | 26.57 | 24.62 | 270.00 | 90.00 | 6.71 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
24 | RETAIL_2_FLR_1_WALL_WEST_DOOR | Door | RETAIL_2_FLR_1_WALL_WEST | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
25 | RETAIL_2_FLR_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 45.89 | 45.89 | 45.89 | 180.00 | 90.00 | 11.58 | 3.96 | 0.00 | RETAIL_1_FLR_1_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
26 | RETAIL_2_FLR_1_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 45.89 | 45.89 | 45.89 | 0.00 | 90.00 | 11.58 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_2_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
27 | RETAIL_2_FLR_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.57 | 26.57 | 26.57 | 90.00 | 90.00 | 6.71 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_3_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
28 | RETAIL_2_FLR_1_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 77.67 | 77.67 | 77.67 | 0.00 | 180.00 | 11.58 | 6.71 | 0.00 | BASEMENT_CEILING_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
29 | RETAIL_2_FLR_1_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 77.67 | 77.67 | 77.67 | 180.00 | 0.00 | 11.58 | 6.71 | 0.00 | RETAIL_2_FLR_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
30 | RETAIL_2_FLR_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 155.34 | 155.34 | 155.34 | 0.00 | 90.00 | 155.34 | 1.00 | 0.00 | RETAIL_2_FLR_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
31 | MECH_FLR_1_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.969 | 0.846 | 62.80 | 62.80 | 62.80 | 0.00 | 90.00 | 15.85 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
32 | MECH_FLR_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 41.06 | 41.06 | 41.06 | 90.00 | 90.00 | 10.36 | 3.96 | 0.00 | STORAGE_FLR_1_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
33 | MECH_FLR_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 62.80 | 62.80 | 62.80 | 180.00 | 90.00 | 15.85 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_3_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
34 | MECH_FLR_1_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 41.06 | 41.06 | 41.06 | 270.00 | 90.00 | 10.36 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_1_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
35 | MECH_FLR_1_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 164.24 | 164.24 | 164.24 | 0.00 | 180.00 | 15.85 | 10.36 | 0.00 | BASEMENT_CEILING_3 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
36 | MECH_FLR_1_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 164.24 | 164.24 | 164.24 | 180.00 | 0.00 | 15.85 | 10.36 | 0.00 | MECH_FLR_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
37 | MECH_FLR_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 328.49 | 328.49 | 328.49 | 0.00 | 90.00 | 328.49 | 1.00 | 0.00 | MECH_FLR_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
38 | STORAGE_FLR_1_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.969 | 0.846 | 28.80 | 36.23 | 28.80 | 0.00 | 90.00 | 9.14 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
39 | STORAGE_FLR_1_WALL_NORTH_ROLLDOOR | Door | STORAGE_FLR_1_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.198 | 1.198 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
40 | STORAGE_FLR_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 41.06 | 41.06 | 41.06 | 90.00 | 90.00 | 10.36 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_4_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
41 | STORAGE_FLR_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 36.23 | 36.23 | 36.23 | 180.00 | 90.00 | 9.14 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_4_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
42 | STORAGE_FLR_1_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 41.06 | 41.06 | 41.06 | 270.00 | 90.00 | 10.36 | 3.96 | 0.00 | MECH_FLR_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
43 | STORAGE_FLR_1_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 94.76 | 94.76 | 94.76 | 0.00 | 180.00 | 9.14 | 10.36 | 0.00 | BASEMENT_CEILING_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
44 | STORAGE_FLR_1_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 94.76 | 94.76 | 94.76 | 180.00 | 0.00 | 9.14 | 10.36 | 0.00 | STORAGE_FLR_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
45 | STORAGE_FLR_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 189.52 | 189.52 | 189.52 | 0.00 | 90.00 | 189.52 | 1.00 | 0.00 | STORAGE_FLR_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
46 | LAUNDRY_FLR_1_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.969 | 0.846 | 18.12 | 18.12 | 18.12 | 0.00 | 90.00 | 4.57 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
47 | LAUNDRY_FLR_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.969 | 0.846 | 65.68 | 67.63 | 65.68 | 90.00 | 90.00 | 17.07 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
48 | LAUNDRY_FLR_1_WALL_EAST_DOOR | Door | LAUNDRY_FLR_1_WALL_EAST | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
49 | LAUNDRY_FLR_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.12 | 18.12 | 18.12 | 180.00 | 90.00 | 4.57 | 3.96 | 0.00 | CAFE_FLR_1_WALL_2_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
50 | LAUNDRY_FLR_1_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 67.63 | 67.63 | 67.63 | 270.00 | 90.00 | 17.07 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_3_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
51 | LAUNDRY_FLR_1_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 78.04 | 78.04 | 78.04 | 0.00 | 180.00 | 4.57 | 17.07 | 0.00 | BASEMENT_CEILING_5 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
52 | LAUNDRY_FLR_1_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 78.04 | 78.04 | 78.04 | 180.00 | 0.00 | 4.57 | 17.07 | 0.00 | LAUNDRY_FLR_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
53 | LAUNDRY_FLR_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 156.08 | 156.08 | 156.08 | 0.00 | 90.00 | 156.08 | 1.00 | 0.00 | LAUNDRY_FLR_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
54 | CAFE_FLR_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.969 | 0.846 | 21.00 | 22.95 | 21.00 | 90.00 | 90.00 | 5.79 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
55 | CAFE_FLR_1_WALL_EAST_DOOR | Door | CAFE_FLR_1_WALL_EAST | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
56 | CAFE_FLR_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.969 | 0.846 | 63.73 | 129.23 | 63.73 | 180.00 | 90.00 | 32.61 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
57 | CAFE_FLR_1_WALL_SOUTH_WINDOW | Window | CAFE_FLR_1_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 65.50 | 65.50 | 65.50 | 180.00 | 90.00 | 30.75 | 2.13 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
58 | CAFE_FLR_1_WALL_1_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.11 | 111.11 | 111.11 | 0.00 | 90.00 | 28.04 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_3_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
59 | CAFE_FLR_1_WALL_2_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.12 | 18.12 | 18.12 | 0.00 | 90.00 | 4.57 | 3.96 | 0.00 | LAUNDRY_FLR_1_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
60 | CAFE_FLR_1_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.95 | 22.95 | 22.95 | 270.00 | 90.00 | 5.79 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_2_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | CAFE_FLR_1_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 188.86 | 188.86 | 188.86 | 0.00 | 180.00 | 32.61 | 5.79 | 0.00 | BASEMENT_CEILING_6 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
62 | CAFE_FLR_1_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 188.86 | 188.86 | 188.86 | 180.00 | 0.00 | 32.61 | 5.79 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 3.86E-002 | 0.96 | 4 | ||
63 | CAFE_FLR_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 377.72 | 377.72 | 377.72 | 0.00 | 90.00 | 377.72 | 1.00 | 0.00 | CAFE_FLR_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
64 | LOBBY_FLR_1_WALL_1_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.969 | 0.846 | 209.87 | 213.77 | 209.87 | 0.00 | 90.00 | 53.95 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
65 | LOBBY_FLR_1_WALL_1_NORTH_DOOR1 | Door | LOBBY_FLR_1_WALL_1_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
66 | LOBBY_FLR_1_WALL_1_NORTH_DOOR2 | Door | LOBBY_FLR_1_WALL_1_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
67 | LOBBY_FLR_1_WALL_2_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.969 | 0.846 | 12.08 | 12.08 | 12.08 | 0.00 | 90.00 | 3.05 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
68 | LOBBY_FLR_1_WALL_1_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.969 | 0.846 | 82.79 | 167.88 | 82.79 | 180.00 | 90.00 | 42.37 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
69 | LOBBY_FLR_1_WALL_SOUTH_WINDOW | Window | LOBBY_FLR_1_WALL_1_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 85.08 | 85.08 | 85.08 | 180.00 | 90.00 | 39.95 | 2.13 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
70 | LOBBY_FLR_1_WALL_1_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.969 | 0.846 | 41.06 | 41.06 | 41.06 | 270.00 | 90.00 | 10.36 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
71 | LOBBY_FLR_1_WALL_2_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 45.89 | 45.89 | 45.89 | 180.00 | 90.00 | 11.58 | 3.96 | 0.00 | RETAIL_2_FLR_1_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
72 | LOBBY_FLR_1_WALL_3_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.11 | 111.11 | 111.11 | 180.00 | 90.00 | 28.04 | 3.96 | 0.00 | CAFE_FLR_1_WALL_1_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
73 | LOBBY_FLR_1_WALL_2_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.95 | 22.95 | 22.95 | 270.00 | 90.00 | 5.79 | 3.96 | 0.00 | RETAIL_1_FLR_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
74 | LOBBY_FLR_1_WALL_3_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.57 | 26.57 | 26.57 | 270.00 | 90.00 | 6.71 | 3.96 | 0.00 | RETAIL_2_FLR_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
75 | LOBBY_FLR_1_WALL_4_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 41.06 | 41.06 | 41.06 | 270.00 | 90.00 | 10.36 | 3.96 | 0.00 | STORAGE_FLR_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
76 | LOBBY_FLR_1_WALL_3_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 62.80 | 62.80 | 62.80 | 0.00 | 90.00 | 15.85 | 3.96 | 0.00 | MECH_FLR_1_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
77 | LOBBY_FLR_1_WALL_4_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 36.23 | 36.23 | 36.23 | 0.00 | 90.00 | 9.14 | 3.96 | 0.00 | STORAGE_FLR_1_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
78 | LOBBY_FLR_1_WALL_1_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 41.06 | 41.06 | 41.06 | 90.00 | 90.00 | 10.36 | 3.96 | 0.00 | MECH_FLR_1_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
79 | LOBBY_FLR_1_WALL_2_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.95 | 22.95 | 22.95 | 90.00 | 90.00 | 5.79 | 3.96 | 0.00 | CAFE_FLR_1_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
80 | LOBBY_FLR_1_WALL_3_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 67.63 | 67.63 | 67.63 | 90.00 | 90.00 | 17.07 | 3.96 | 0.00 | LAUNDRY_FLR_1_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
81 | LOBBY_FLR_1_FLOOR_1 | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 1088.56 | 1088.56 | 1088.56 | 180.00 | 180.00 | 32.99 | 32.99 | 0.00 | BASEMENT_CEILING_7 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 6 | ||
82 | LOBBY_FLR_1_FLOOR_2 | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 219.63 | 219.63 | 219.63 | 90.00 | 180.00 | 14.82 | 14.82 | 0.00 | BASEMENT_CEILING_8 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 6 | ||
83 | LOBBY_FLR_1_CEILING_1 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 1062.83 | 1062.83 | 1062.83 | 270.00 | 0.00 | 32.60 | 32.60 | 0.00 | LOBBY_FLR_1_CEILING_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 10 | ||
84 | LOBBY_FLR_1_CEILING_2 | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 245.35 | 245.35 | 245.35 | 180.00 | 0.00 | 42.37 | 5.79 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.22E-003 | 1.00 | 4 | ||
85 | LOBBY_FLR_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 2616.37 | 2616.37 | 2616.37 | 0.00 | 90.00 | 2616.37 | 1.00 | 0.00 | LOBBY_FLR_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
86 | ROOM_1_FLR_3_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.217 | 1.029 | 9.34 | 13.94 | 9.34 | 180.00 | 90.00 | 4.57 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
87 | ROOM_1_FLR_3_WALL_SOUTH_WINDOW | Window | ROOM_1_FLR_3_WALL_SOUTH | Window5 Detailed Fenestration | RESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 4.60 | 4.60 | 4.60 | 180.00 | 90.00 | 3.77 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
88 | ROOM_1_FLR_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.217 | 1.029 | 17.43 | 26.01 | 17.43 | 270.00 | 90.00 | 8.54 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
89 | ROOM_1_FLR_3_WALL_WEST_WINDOW | Window | ROOM_1_FLR_3_WALL_WEST | Window5 Detailed Fenestration | RESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 8.58 | 8.58 | 8.58 | 270.00 | 90.00 | 7.04 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
90 | ROOM_1_FLR_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.94 | 13.94 | 13.94 | 0.00 | 90.00 | 4.57 | 3.05 | 0.00 | ROOM_2_FLR_3_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
91 | ROOM_1_FLR_3_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 90.00 | 90.00 | 8.54 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_3_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
92 | ROOM_1_FLR_3_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 39.02 | 39.02 | 39.02 | 0.00 | 180.00 | 4.57 | 8.54 | 0.00 | ROOM_1_FLR_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
93 | ROOM_1_FLR_3_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 39.02 | 39.02 | 39.02 | 180.00 | 0.00 | 4.57 | 8.54 | 0.00 | ROOM_1_FLR_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
94 | ROOM_1_FLR_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 78.04 | 78.04 | 78.04 | 0.00 | 90.00 | 78.04 | 1.00 | 0.00 | ROOM_1_FLR_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
95 | ROOM_2_FLR_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.217 | 1.029 | 9.34 | 13.94 | 9.34 | 0.00 | 90.00 | 4.57 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
96 | ROOM_2_FLR_3_WALL_NORTH_WINDOW | Window | ROOM_2_FLR_3_WALL_NORTH | Window5 Detailed Fenestration | RESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 4.60 | 4.60 | 4.60 | 0.00 | 90.00 | 3.77 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
97 | ROOM_2_FLR_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.217 | 1.029 | 17.43 | 26.01 | 17.43 | 270.00 | 90.00 | 8.53 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
98 | ROOM_2_FLR_3_WALL_WEST_WINDOW | Window | ROOM_2_FLR_3_WALL_WEST | Window5 Detailed Fenestration | RESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 8.58 | 8.58 | 8.58 | 270.00 | 90.00 | 7.04 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
99 | ROOM_2_FLR_3_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 90.00 | 90.00 | 8.53 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_4_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
100 | ROOM_2_FLR_3_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.94 | 13.94 | 13.94 | 180.00 | 90.00 | 4.57 | 3.05 | 0.00 | ROOM_1_FLR_3_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
101 | ROOM_2_FLR_3_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 39.02 | 39.02 | 39.02 | 0.00 | 180.00 | 4.57 | 8.53 | 0.00 | ROOM_2_FLR_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
102 | ROOM_2_FLR_3_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 39.02 | 39.02 | 39.02 | 180.00 | 0.00 | 4.57 | 8.53 | 0.00 | ROOM_2_FLR_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
103 | ROOM_2_FLR_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 78.03 | 78.03 | 78.03 | 0.00 | 90.00 | 78.03 | 1.00 | 0.00 | ROOM_2_FLR_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
104 | ROOM_3_MULT19_FLR_3_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.217 | 1.029 | 7.47 | 11.15 | 7.47 | 180.00 | 90.00 | 3.66 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
105 | ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW | Window | ROOM_3_MULT19_FLR_3_WALL_SOUTH | Window5 Detailed Fenestration | RESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 3.68 | 3.68 | 3.68 | 180.00 | 90.00 | 3.02 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
106 | ROOM_3_MULT19_FLR_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 11.15 | 11.15 | 11.15 | 0.00 | 90.00 | 3.66 | 3.05 | 0.00 | ROOM_3_MULT19_FLR_3_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
107 | ROOM_3_MULT19_FLR_3_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 90.00 | 90.00 | 6.71 | 3.05 | 0.00 | ROOM_3_MULT19_FLR_3_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
108 | ROOM_3_MULT19_FLR_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 270.00 | 90.00 | 6.71 | 3.05 | 0.00 | ROOM_3_MULT19_FLR_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
109 | ROOM_3_MULT19_FLR_3_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 24.52 | 24.52 | 24.52 | 0.00 | 180.00 | 3.66 | 6.71 | 0.00 | ROOM_3_MULT19_FLR_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
110 | ROOM_3_MULT19_FLR_3_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 24.52 | 24.52 | 24.52 | 180.00 | 0.00 | 3.66 | 6.71 | 0.00 | ROOM_3_MULT19_FLR_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
111 | ROOM_3_MULT19_FLR_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 49.05 | 49.05 | 49.05 | 0.00 | 90.00 | 49.05 | 1.00 | 0.00 | ROOM_3_MULT19_FLR_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
112 | ROOM_4_MULT19_FLR_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.217 | 1.029 | 7.47 | 11.15 | 7.47 | 0.00 | 90.00 | 3.66 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
113 | ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW | Window | ROOM_4_MULT19_FLR_3_WALL_NORTH | Window5 Detailed Fenestration | RESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 3.68 | 3.68 | 3.68 | 0.00 | 90.00 | 3.02 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
114 | ROOM_4_MULT19_FLR_3_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 90.00 | 90.00 | 6.71 | 3.05 | 0.00 | ROOM_4_MULT19_FLR_3_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
115 | ROOM_4_MULT19_FLR_3_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 11.15 | 11.15 | 11.15 | 180.00 | 90.00 | 3.66 | 3.05 | 0.00 | ROOM_4_MULT19_FLR_3_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
116 | ROOM_4_MULT19_FLR_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 270.00 | 90.00 | 6.71 | 3.05 | 0.00 | ROOM_4_MULT19_FLR_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
117 | ROOM_4_MULT19_FLR_3_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 24.53 | 24.53 | 24.53 | 0.00 | 180.00 | 3.66 | 6.71 | 0.00 | ROOM_4_MULT19_FLR_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
118 | ROOM_4_MULT19_FLR_3_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 24.53 | 24.53 | 24.53 | 180.00 | 0.00 | 3.66 | 6.71 | 0.00 | ROOM_4_MULT19_FLR_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
119 | ROOM_4_MULT19_FLR_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 49.06 | 49.06 | 49.06 | 0.00 | 90.00 | 49.06 | 1.00 | 0.00 | ROOM_4_MULT19_FLR_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
120 | ROOM_5_FLR_3_WALL_EAST | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.217 | 1.029 | 17.43 | 26.01 | 17.43 | 90.00 | 90.00 | 8.54 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
121 | ROOM_5_FLR_3_WALL_EAST_WINDOW | Window | ROOM_5_FLR_3_WALL_EAST | Window5 Detailed Fenestration | RESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 8.58 | 8.58 | 8.58 | 90.00 | 90.00 | 7.04 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
122 | ROOM_5_FLR_3_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.217 | 1.029 | 9.34 | 13.94 | 9.34 | 180.00 | 90.00 | 4.57 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
123 | ROOM_5_FLR_3_WALL_SOUTH_WINDOW | Window | ROOM_5_FLR_3_WALL_SOUTH | Window5 Detailed Fenestration | RESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 4.60 | 4.60 | 4.60 | 180.00 | 90.00 | 3.77 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
124 | ROOM_5_FLR_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.94 | 13.94 | 13.94 | 0.00 | 90.00 | 4.57 | 3.05 | 0.00 | ROOM_6_FLR_3_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
125 | ROOM_5_FLR_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 270.00 | 90.00 | 8.54 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_3_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
126 | ROOM_5_FLR_3_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 39.02 | 39.02 | 39.02 | 0.00 | 180.00 | 4.57 | 8.54 | 0.00 | ROOM_5_FLR_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
127 | ROOM_5_FLR_3_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 39.02 | 39.02 | 39.02 | 180.00 | 0.00 | 4.57 | 8.54 | 0.00 | ROOM_5_FLR_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
128 | ROOM_5_FLR_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 78.04 | 78.04 | 78.04 | 0.00 | 90.00 | 78.04 | 1.00 | 0.00 | ROOM_5_FLR_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
129 | ROOM_6_FLR_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.217 | 1.029 | 9.34 | 13.94 | 9.34 | 0.00 | 90.00 | 4.57 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
130 | ROOM_6_FLR_3_WALL_NORTH_WINDOW | Window | ROOM_6_FLR_3_WALL_NORTH | Window5 Detailed Fenestration | RESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 4.60 | 4.60 | 4.60 | 0.00 | 90.00 | 3.77 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
131 | ROOM_6_FLR_3_WALL_EAST | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_MID | 1.217 | 1.029 | 17.43 | 26.01 | 17.43 | 90.00 | 90.00 | 8.53 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
132 | ROOM_6_FLR_3_WALL_EAST_WINDOW | Window | ROOM_6_FLR_3_WALL_EAST | Window5 Detailed Fenestration | RESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 8.58 | 8.58 | 8.58 | 90.00 | 90.00 | 7.04 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
133 | ROOM_6_FLR_3_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.94 | 13.94 | 13.94 | 180.00 | 90.00 | 4.57 | 3.05 | 0.00 | ROOM_5_FLR_3_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
134 | ROOM_6_FLR_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 270.00 | 90.00 | 8.53 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_4_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
135 | ROOM_6_FLR_3_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 39.02 | 39.02 | 39.02 | 0.00 | 180.00 | 4.57 | 8.53 | 0.00 | ROOM_6_FLR_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
136 | ROOM_6_FLR_3_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 39.02 | 39.02 | 39.02 | 180.00 | 0.00 | 4.57 | 8.53 | 0.00 | ROOM_6_FLR_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
137 | ROOM_6_FLR_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 78.03 | 78.03 | 78.03 | 0.00 | 90.00 | 78.03 | 1.00 | 0.00 | ROOM_6_FLR_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
138 | CORRIDOR_FLR_3_WALL_1_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.265 | 1.063 | 11.83 | 17.65 | 11.83 | 0.00 | 90.00 | 5.79 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
139 | CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW | Window | CORRIDOR_FLR_3_WALL_1_NORTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 5.82 | 5.82 | 5.82 | 0.00 | 90.00 | 4.78 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
140 | CORRIDOR_FLR_3_WALL_2_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.265 | 1.063 | 4.35 | 6.50 | 4.35 | 0.00 | 90.00 | 2.13 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
141 | CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW | Window | CORRIDOR_FLR_3_WALL_2_NORTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 2.15 | 2.15 | 2.15 | 0.00 | 90.00 | 1.76 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
142 | CORRIDOR_FLR_3_WALL_1_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.265 | 1.063 | 4.36 | 6.50 | 4.36 | 180.00 | 90.00 | 2.13 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
143 | CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW | Window | CORRIDOR_FLR_3_WALL_1_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 2.15 | 2.15 | 2.15 | 180.00 | 90.00 | 1.76 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
144 | CORRIDOR_FLR_3_WALL_2_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.265 | 1.063 | 11.83 | 17.65 | 11.83 | 180.00 | 90.00 | 5.79 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
145 | CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW | Window | CORRIDOR_FLR_3_WALL_2_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 5.82 | 5.82 | 5.82 | 180.00 | 90.00 | 4.78 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
146 | CORRIDOR_FLR_3_WALL_3_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 211.82 | 211.82 | 211.82 | 0.00 | 90.00 | 69.50 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_3_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
147 | CORRIDOR_FLR_3_WALL_1_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 90.00 | 90.00 | 6.71 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_1_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
148 | CORRIDOR_FLR_3_WALL_2_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 90.00 | 90.00 | 6.71 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_2_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
149 | CORRIDOR_FLR_3_WALL_3_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 90.00 | 90.00 | 8.54 | 3.05 | 0.00 | ROOM_5_FLR_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
150 | CORRIDOR_FLR_3_WALL_4_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 90.00 | 90.00 | 8.53 | 3.05 | 0.00 | ROOM_6_FLR_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
151 | CORRIDOR_FLR_3_WALL_3_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 211.82 | 211.82 | 211.82 | 180.00 | 90.00 | 69.49 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_3_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
152 | CORRIDOR_FLR_3_WALL_1_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 270.00 | 90.00 | 6.71 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_1_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
153 | CORRIDOR_FLR_3_WALL_2_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 270.00 | 90.00 | 6.71 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_2_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
154 | CORRIDOR_FLR_3_WALL_3_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 270.00 | 90.00 | 8.54 | 3.05 | 0.00 | ROOM_1_FLR_3_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
155 | CORRIDOR_FLR_3_WALL_4_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 270.00 | 90.00 | 8.53 | 3.05 | 0.00 | ROOM_2_FLR_3_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
156 | CORRIDOR_FLR_3_FLOOR_1 | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 74.32 | 74.32 | 74.32 | 180.00 | 180.00 | 8.62 | 8.62 | 0.00 | CORRIDOR_FLR_3_FLOOR_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 6 | ||
157 | CORRIDOR_FLR_3_FLOOR_2 | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 240.77 | 240.77 | 240.77 | 270.00 | 180.00 | 3.66 | 65.84 | 0.00 | CORRIDOR_FLR_3_FLOOR_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
158 | CORRIDOR_FLR_3_FLOOR_3 | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 74.32 | 74.32 | 74.32 | 90.00 | 180.00 | 8.62 | 8.62 | 0.00 | CORRIDOR_FLR_3_FLOOR_3 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 6 | ||
159 | CORRIDOR_FLR_3_CEILING_1 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 74.32 | 74.32 | 74.32 | 90.00 | 0.00 | 8.62 | 8.62 | 0.00 | CORRIDOR_FLR_3_CEILING_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 6 | ||
160 | CORRIDOR_FLR_3_CEILING_2 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 240.77 | 240.77 | 240.77 | 90.00 | 0.00 | 3.66 | 65.84 | 0.00 | CORRIDOR_FLR_3_CEILING_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
161 | CORRIDOR_FLR_3_CEILING_3 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 74.32 | 74.32 | 74.32 | 90.00 | 0.00 | 8.62 | 8.62 | 0.00 | CORRIDOR_FLR_3_CEILING_3 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 6 | ||
162 | CORRIDOR_FLR_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 778.81 | 778.81 | 778.81 | 0.00 | 90.00 | 778.81 | 1.00 | 0.00 | CORRIDOR_FLR_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
163 | ROOM_1_FLR_6_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.286 | 1.078 | 9.34 | 13.94 | 9.34 | 180.00 | 90.00 | 4.57 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
164 | ROOM_1_FLR_6_WALL_SOUTH_WINDOW | Window | ROOM_1_FLR_6_WALL_SOUTH | Window5 Detailed Fenestration | RESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 4.60 | 4.60 | 4.60 | 180.00 | 90.00 | 3.77 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
165 | ROOM_1_FLR_6_WALL_WEST | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.286 | 1.078 | 17.43 | 26.01 | 17.43 | 270.00 | 90.00 | 8.54 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
166 | ROOM_1_FLR_6_WALL_WEST_WINDOW | Window | ROOM_1_FLR_6_WALL_WEST | Window5 Detailed Fenestration | RESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 8.58 | 8.58 | 8.58 | 270.00 | 90.00 | 7.04 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
167 | ROOM_1_FLR_6_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.94 | 13.94 | 13.94 | 0.00 | 90.00 | 4.57 | 3.05 | 0.00 | ROOM_2_FLR_6_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
168 | ROOM_1_FLR_6_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 90.00 | 90.00 | 8.54 | 3.05 | 0.00 | ROOM_1_FLR_6_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
169 | ROOM_1_FLR_6_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 39.02 | 39.02 | 39.02 | 0.00 | 180.00 | 4.57 | 8.54 | 0.00 | ROOM_1_FLR_6_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
170 | ROOM_1_FLR_6_CEILING | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 39.02 | 39.02 | 39.02 | 180.00 | 0.00 | 4.57 | 8.54 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
171 | ROOM_1_FLR_6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 78.04 | 78.04 | 78.04 | 0.00 | 90.00 | 78.04 | 1.00 | 0.00 | ROOM_1_FLR_6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
172 | ROOM_2_FLR_6_WALL_NORTH | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.286 | 1.078 | 9.34 | 13.94 | 9.34 | 0.00 | 90.00 | 4.57 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
173 | ROOM_2_FLR_6_WALL_NORTH_WINDOW | Window | ROOM_2_FLR_6_WALL_NORTH | Window5 Detailed Fenestration | RESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 4.60 | 4.60 | 4.60 | 0.00 | 90.00 | 3.77 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
174 | ROOM_2_FLR_6_WALL_WEST | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.286 | 1.078 | 17.43 | 26.01 | 17.43 | 270.00 | 90.00 | 8.53 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
175 | ROOM_2_FLR_6_WALL_WEST_WINDOW | Window | ROOM_2_FLR_6_WALL_WEST | Window5 Detailed Fenestration | RESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 8.58 | 8.58 | 8.58 | 270.00 | 90.00 | 7.04 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
176 | ROOM_2_FLR_6_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 90.00 | 90.00 | 8.53 | 3.05 | 0.00 | ROOM_2_FLR_6_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
177 | ROOM_2_FLR_6_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.94 | 13.94 | 13.94 | 180.00 | 90.00 | 4.57 | 3.05 | 0.00 | ROOM_1_FLR_6_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
178 | ROOM_2_FLR_6_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 39.02 | 39.02 | 39.02 | 0.00 | 180.00 | 4.57 | 8.53 | 0.00 | ROOM_2_FLR_6_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
179 | ROOM_2_FLR_6_CEILING | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 39.02 | 39.02 | 39.02 | 180.00 | 0.00 | 4.57 | 8.53 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
180 | ROOM_2_FLR_6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 78.03 | 78.03 | 78.03 | 0.00 | 90.00 | 78.03 | 1.00 | 0.00 | ROOM_2_FLR_6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
181 | ROOM_3_MULT9_FLR_6_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | RES_EXT_WALL_TOP | 1.286 | 1.078 | 13.70 | 20.44 | 13.70 | 180.00 | 90.00 | 6.71 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
182 | ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW | Window | ROOM_3_MULT9_FLR_6_WALL_SOUTH | Window5 Detailed Fenestration | RESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 6.74 | 6.74 | 6.74 | 180.00 | 90.00 | 5.53 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
183 | ROOM_3_MULT9_FLR_6_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 0.00 | 90.00 | 6.71 | 3.05 | 0.00 | ROOM_3_MULT9_FLR_6_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
184 | ROOM_3_MULT9_FLR_6_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 11.15 | 11.15 | 11.15 | 90.00 | 90.00 | 3.66 | 3.05 | 0.00 | ROOM_3_MULT9_FLR_6_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
185 | ROOM_3_MULT9_FLR_6_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 11.15 | 11.15 | 11.15 | 270.00 | 90.00 | 3.66 | 3.05 | 0.00 | ROOM_3_MULT9_FLR_6_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
186 | ROOM_3_MULT9_FLR_6_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 24.53 | 24.53 | 24.53 | 0.00 | 180.00 | 6.71 | 3.66 | 0.00 | ROOM_3_MULT9_FLR_6_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
187 | ROOM_3_MULT9_FLR_6_CEILING | Roof | CTF - ConductionTransferFunction | RES_ROOF | 0.283 | 0.269 | 24.53 | 24.53 | 24.53 | 180.00 | 0.00 | 6.71 | 3.66 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
188 | ROOM_3_MULT9_FLR_6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 49.06 | 49.06 | 49.06 | 0.00 | 90.00 | 49.06 | 1.00 | 0.00 | ROOM_3_MULT9_FLR_6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
189 | BANQUET_FLR_6_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.335 | 1.112 | 65.36 | 97.55 | 65.36 | 0.00 | 90.00 | 32.00 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
190 | BANQUET_FLR_6_WALL_NORTH_WINDOW | Window | BANQUET_FLR_6_WALL_NORTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 32.19 | 32.19 | 32.19 | 0.00 | 90.00 | 26.40 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
191 | BANQUET_FLR_6_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 31.59 | 31.59 | 31.59 | 90.00 | 90.00 | 10.36 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_3_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
192 | BANQUET_FLR_6_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 97.55 | 97.55 | 97.55 | 180.00 | 90.00 | 32.00 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_3_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
193 | BANQUET_FLR_6_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 31.59 | 31.59 | 31.59 | 270.00 | 90.00 | 10.36 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_1_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
194 | BANQUET_FLR_6_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 331.66 | 331.66 | 331.66 | 0.00 | 180.00 | 32.00 | 10.36 | 0.00 | BANQUET_FLR_6_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
195 | BANQUET_FLR_6_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 331.66 | 331.66 | 331.66 | 180.00 | 0.00 | 32.00 | 10.36 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
196 | BANQUET_FLR_6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 663.31 | 663.31 | 663.31 | 0.00 | 90.00 | 663.31 | 1.00 | 0.00 | BANQUET_FLR_6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
197 | DINING_FLR_6_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.335 | 1.112 | 65.36 | 97.55 | 65.36 | 0.00 | 90.00 | 32.00 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
198 | DINING_FLR_6_WALL_NORTH_WINDOW | Window | DINING_FLR_6_WALL_NORTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 32.19 | 32.19 | 32.19 | 0.00 | 90.00 | 26.40 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
199 | DINING_FLR_6_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 31.59 | 31.59 | 31.59 | 90.00 | 90.00 | 10.36 | 3.05 | 0.00 | KITCHEN_FLR_6_WALL_2_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
200 | DINING_FLR_6_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 97.55 | 97.55 | 97.55 | 180.00 | 90.00 | 32.00 | 3.05 | 0.00 | DINING_FLR_6_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
201 | DINING_FLR_6_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 31.59 | 31.59 | 31.59 | 270.00 | 90.00 | 10.36 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_2_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
202 | DINING_FLR_6_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 331.66 | 331.66 | 331.66 | 0.00 | 180.00 | 32.00 | 10.36 | 0.00 | DINING_FLR_6_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
203 | DINING_FLR_6_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 331.66 | 331.66 | 331.66 | 180.00 | 0.00 | 32.00 | 10.36 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
204 | DINING_FLR_6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 663.31 | 663.31 | 663.31 | 0.00 | 90.00 | 663.31 | 1.00 | 0.00 | DINING_FLR_6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
205 | KITCHEN_FLR_6_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.335 | 1.112 | 16.77 | 21.37 | 16.77 | 0.00 | 90.00 | 7.01 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
206 | KITCHEN_FLR_6_WALL_NORTH_WINDOW | Window | KITCHEN_FLR_6_WALL_NORTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 4.60 | 4.60 | 4.60 | 0.00 | 90.00 | 3.77 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
207 | KITCHEN_FLR_6_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.335 | 1.112 | 34.86 | 52.03 | 34.86 | 90.00 | 90.00 | 17.07 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
208 | KITCHEN_FLR_6_WALL_EAST_WINDOW | Window | KITCHEN_FLR_6_WALL_EAST | Window5 Detailed Fenestration | NONRESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 17.17 | 17.17 | 17.17 | 90.00 | 90.00 | 14.08 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
209 | KITCHEN_FLR_6_WALL_1_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.335 | 1.112 | 9.34 | 13.94 | 9.34 | 180.00 | 90.00 | 4.57 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
210 | KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW | Window | KITCHEN_FLR_6_WALL_1_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 4.60 | 4.60 | 4.60 | 180.00 | 90.00 | 3.77 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
211 | KITCHEN_FLR_6_WALL_2_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 7.43 | 7.43 | 7.43 | 180.00 | 90.00 | 2.44 | 3.05 | 0.00 | KITCHEN_FLR_6_WALL_2_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
212 | KITCHEN_FLR_6_WALL_1_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 270.00 | 90.00 | 6.71 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_3_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
213 | KITCHEN_FLR_6_WALL_2_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 31.59 | 31.59 | 31.59 | 270.00 | 90.00 | 10.36 | 3.05 | 0.00 | DINING_FLR_6_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
214 | KITCHEN_FLR_6_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 103.30 | 103.30 | 103.30 | 180.00 | 180.00 | 10.16 | 10.16 | 0.00 | KITCHEN_FLR_6_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 6 | ||
215 | KITCHEN_FLR_6_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 103.30 | 103.30 | 103.30 | 270.00 | 0.00 | 10.16 | 10.16 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 6 | ||
216 | KITCHEN_FLR_6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 206.61 | 206.61 | 206.61 | 0.00 | 90.00 | 206.61 | 1.00 | 0.00 | KITCHEN_FLR_6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
217 | CORRIDOR_FLR_6_WALL_1_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.335 | 1.112 | 11.83 | 17.65 | 11.83 | 0.00 | 90.00 | 5.79 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
218 | CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW | Window | CORRIDOR_FLR_6_WALL_1_NORTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 5.82 | 5.82 | 5.82 | 0.00 | 90.00 | 4.78 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
219 | CORRIDOR_FLR_6_WALL_2_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.335 | 1.112 | 10.58 | 15.79 | 10.58 | 0.00 | 90.00 | 5.18 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
220 | CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW | Window | CORRIDOR_FLR_6_WALL_2_NORTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 5.21 | 5.21 | 5.21 | 0.00 | 90.00 | 4.27 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
221 | CORRIDOR_FLR_6_WALL_2_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.335 | 1.112 | 34.86 | 52.03 | 34.86 | 180.00 | 90.00 | 17.07 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
222 | CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW | Window | CORRIDOR_FLR_6_WALL_2_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.4711_SHGC_0.25 | N/A | 2.678 | No | 17.17 | 17.17 | 17.17 | 180.00 | 90.00 | 14.08 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
223 | CORRIDOR_FLR_6_WALL_3_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 97.55 | 97.55 | 97.55 | 0.00 | 90.00 | 32.00 | 3.05 | 0.00 | BANQUET_FLR_6_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
224 | CORRIDOR_FLR_6_WALL_4_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 104.98 | 104.98 | 104.98 | 0.00 | 90.00 | 34.44 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_4_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
225 | CORRIDOR_FLR_6_WALL_1_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 183.95 | 183.95 | 183.95 | 180.00 | 90.00 | 60.35 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_1_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
226 | CORRIDOR_FLR_6_WALL_1_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 11.15 | 11.15 | 11.15 | 270.00 | 90.00 | 3.66 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_1_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
227 | CORRIDOR_FLR_6_WALL_2_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 40.88 | 40.88 | 40.88 | 270.00 | 90.00 | 13.41 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_2_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
228 | CORRIDOR_FLR_6_WALL_3_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 31.59 | 31.59 | 31.59 | 270.00 | 90.00 | 10.36 | 3.05 | 0.00 | BANQUET_FLR_6_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
229 | CORRIDOR_FLR_6_WALL_1_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 31.59 | 31.59 | 31.59 | 90.00 | 90.00 | 10.36 | 3.05 | 0.00 | BANQUET_FLR_6_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
230 | CORRIDOR_FLR_6_WALL_2_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 31.59 | 31.59 | 31.59 | 90.00 | 90.00 | 10.36 | 3.05 | 0.00 | DINING_FLR_6_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
231 | CORRIDOR_FLR_6_WALL_3_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 90.00 | 90.00 | 6.71 | 3.05 | 0.00 | KITCHEN_FLR_6_WALL_1_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
232 | CORRIDOR_FLR_6_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 412.12 | 412.12 | 412.12 | 180.00 | 180.00 | 20.30 | 20.30 | 0.00 | CORRIDOR_FLR_6_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 12 | ||
233 | CORRIDOR_FLR_6_CEILING_1 | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 244.71 | 244.71 | 244.71 | 90.00 | 0.00 | 15.64 | 15.64 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 8 | ||
234 | CORRIDOR_FLR_6_CEILING_2 | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 167.42 | 167.42 | 167.42 | 270.00 | 0.00 | 12.94 | 12.94 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 6 | ||
235 | CORRIDOR_FLR_6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 824.25 | 824.25 | 824.25 | 0.00 | 90.00 | 824.25 | 1.00 | 0.00 | CORRIDOR_FLR_6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes | Clark and Allen |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1Environment:Special Days |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | BASEMENT | RunPeriod: RUNPERIOD 1 | 5.5939207354E-003 | 1.2960960576E-002 | Pass | Pass | 1.3631900692E-002 | 3.3033095149E-002 | Pass | Pass |
2 | RETAIL_1_FLR_1 | RunPeriod: RUNPERIOD 1 | 2.2927880939E-003 | 1.7121218069E-003 | Pass | Pass | 0.2553214408 | 0.5002104865 | Pass | Pass |
3 | RETAIL_2_FLR_1 | RunPeriod: RUNPERIOD 1 | 1.4344505979E-003 | 1.0295486498E-003 | Pass | Pass | 2.3422953477E-002 | 4.9231801105E-002 | Pass | Pass |
4 | MECH_FLR_1 | RunPeriod: RUNPERIOD 1 | 9.0720551300E-004 | 6.9371916652E-004 | Pass | Pass | 4.4992419874E-002 | 7.5051834207E-002 | Pass | Pass |
5 | STORAGE_FLR_1 | RunPeriod: RUNPERIOD 1 | 9.4563334914E-004 | 6.8482070699E-004 | Pass | Pass | 0.1835769261 | 0.5612444604 | Pass | Pass |
6 | LAUNDRY_FLR_1 | RunPeriod: RUNPERIOD 1 | 4.3231247400E-002 | 0.1347716619 | Pass | Pass | 1.9187256588E-002 | 5.6068612477E-002 | Pass | Pass |
7 | CAFE_FLR_1 | RunPeriod: RUNPERIOD 1 | 3.2327109121E-003 | 2.1398569785E-003 | Pass | Pass | 3.1251556090E-002 | 7.3483169539E-002 | Pass | Pass |
8 | LOBBY_FLR_1 | RunPeriod: RUNPERIOD 1 | 2.4942889900E-003 | 5.1927993693E-003 | Pass | Pass | 2.0853989322E-002 | 5.2871793176E-002 | Pass | Pass |
9 | ROOM_1_FLR_3 | RunPeriod: RUNPERIOD 1 | 6.2618128800E-002 | 0.2139809506 | Pass | Pass | 0.3163132059 | 1.6761819639 | Pass | Pass |
10 | ROOM_2_FLR_3 | RunPeriod: RUNPERIOD 1 | 6.4435914678E-002 | 0.2197171948 | Pass | Pass | 0.3521005048 | 1.7415821609 | Pass | Pass |
11 | ROOM_3_MULT19_FLR_3 | RunPeriod: RUNPERIOD 1 | 3.2844118416E-002 | 3.5245900925E-002 | Pass | Pass | 6.7377115519E-003 | 7.6358172949E-003 | Pass | Pass |
12 | ROOM_4_MULT19_FLR_3 | RunPeriod: RUNPERIOD 1 | 2.0648547806E-002 | 8.4492324496E-002 | Pass | Pass | 8.3955263538E-002 | 0.2267006652 | Pass | Pass |
13 | ROOM_5_FLR_3 | RunPeriod: RUNPERIOD 1 | 6.1178362661E-002 | 0.2086057574 | Pass | Pass | 0.3629061102 | 2.4156333735 | Pass | Pass |
14 | ROOM_6_FLR_3 | RunPeriod: RUNPERIOD 1 | 6.3017362972E-002 | 0.2141175417 | Pass | Pass | 0.3284389199 | 1.9039830330 | Pass | Pass |
15 | CORRIDOR_FLR_3 | RunPeriod: RUNPERIOD 1 | 6.4686865796E-004 | 4.8100427321E-004 | Pass | Pass | 0.1028536673 | 0.2462113538 | Pass | Pass |
16 | ROOM_1_FLR_6 | RunPeriod: RUNPERIOD 1 | 8.3609763633E-002 | 0.2797383511 | Pass | Pass | 0.2089877592 | 0.8540586258 | Pass | Pass |
17 | ROOM_2_FLR_6 | RunPeriod: RUNPERIOD 1 | 8.4391090857E-002 | 0.2825061568 | Pass | Pass | 0.2222619057 | 0.8888814191 | Pass | Pass |
18 | ROOM_3_MULT9_FLR_6 | RunPeriod: RUNPERIOD 1 | 4.2856897531E-002 | 0.1554088356 | Pass | Pass | 0.2257601464 | 0.9625100225 | Pass | Pass |
19 | BANQUET_FLR_6 | RunPeriod: RUNPERIOD 1 | 2.3817527150E-002 | 6.6301404080E-002 | Pass | Pass | 1.1576825323E-002 | 3.5133297685E-002 | Pass | Pass |
20 | DINING_FLR_6 | RunPeriod: RUNPERIOD 1 | 2.5705146596E-002 | 6.6537218139E-002 | Pass | Pass | 1.0746335804E-002 | 3.0956310963E-002 | Pass | Pass |
21 | KITCHEN_FLR_6 | RunPeriod: RUNPERIOD 1 | 7.1498807590E-002 | 0.1172679240 | Pass | Pass | 1.6925981469E-002 | 3.2837660497E-002 | Pass | Pass |
22 | CORRIDOR_FLR_6 | RunPeriod: RUNPERIOD 1 | 1.3662824988E-003 | 9.9209795642E-004 | Pass | Pass | 0.3221245656 | 1.1871591019 | Pass | Pass |
Report: Annual Heat Emissions Summary
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
Heat Emission by ComponentsEnvelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
Heat Emissions [GJ] | 2991.92 | 38.30 | 270.19 | 1661.01 | 11365.46 | 16326.88 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | -6.30 | 0.00 | -6.30 | Wetbulb [C] | 5.30 | 320.00 |
ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 34.40 | 9.50 | 23.50 | Wetbulb [C] | 4.00 | 300.00 |
Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
Jan | 0.00 | 0 | |||
Feb | 0.00 | 0 | |||
Mar | 0.00 | 0 | |||
Apr | 0.00 | 0 | |||
May | 0.00 | 0 | |||
Jun | 0.00 | 0 | |||
Jul | 0.00 | 0 | |||
Aug | 0.00 | 0 | |||
Sep | 90.00 | 25 | |||
Oct | 0.00 | 0 | |||
Nov | 0.00 | 0 | |||
Dec | 0.00 | 0 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
BASEMENT_WALL_NORTH | BASEMENT_WALL_NORTH_CFACTOR | 1.00 | 0.845 | 0.940 | 211.13 | 211.13 | 0.00 | 90.00 | N |
BASEMENT_WALL_EAST | BASEMENT_WALL_EAST_CFACTOR | 1.00 | 0.845 | 0.940 | 55.76 | 55.76 | 90.00 | 90.00 | E |
BASEMENT_WALL_SOUTH | BASEMENT_WALL_SOUTH_CFACTOR | 1.00 | 0.845 | 0.940 | 211.13 | 211.13 | 180.00 | 90.00 | S |
BASEMENT_WALL_WEST | BASEMENT_WALL_WEST_CFACTOR | 1.00 | 0.845 | 0.940 | 55.76 | 55.76 | 270.00 | 90.00 | W |
RETAIL_1_FLR_1_WALL_SOUTH | NONRES_EXT_WALL_GRD | 0.30 | 0.846 | 0.969 | 45.89 | 22.63 | 180.00 | 90.00 | S |
RETAIL_1_FLR_1_WALL_WEST | NONRES_EXT_WALL_GRD | 0.30 | 0.846 | 0.969 | 22.95 | 22.95 | 270.00 | 90.00 | W |
RETAIL_1_FLR_1_CEILING | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 67.07 | 67.07 | 180.00 | 0.00 | |
RETAIL_2_FLR_1_WALL_WEST | NONRES_EXT_WALL_GRD | 0.30 | 0.846 | 0.969 | 26.57 | 24.62 | 270.00 | 90.00 | W |
MECH_FLR_1_WALL_NORTH | NONRES_EXT_WALL_GRD | 0.30 | 0.846 | 0.969 | 62.80 | 62.80 | 0.00 | 90.00 | N |
STORAGE_FLR_1_WALL_NORTH | NONRES_EXT_WALL_GRD | 0.30 | 0.846 | 0.969 | 36.23 | 28.80 | 0.00 | 90.00 | N |
LAUNDRY_FLR_1_WALL_NORTH | NONRES_EXT_WALL_GRD | 0.30 | 0.846 | 0.969 | 18.12 | 18.12 | 0.00 | 90.00 | N |
LAUNDRY_FLR_1_WALL_EAST | NONRES_EXT_WALL_GRD | 0.30 | 0.846 | 0.969 | 67.63 | 65.68 | 90.00 | 90.00 | E |
CAFE_FLR_1_WALL_EAST | NONRES_EXT_WALL_GRD | 0.30 | 0.846 | 0.969 | 22.95 | 21.00 | 90.00 | 90.00 | E |
CAFE_FLR_1_WALL_SOUTH | NONRES_EXT_WALL_GRD | 0.30 | 0.846 | 0.969 | 129.23 | 63.73 | 180.00 | 90.00 | S |
CAFE_FLR_1_CEILING | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 188.86 | 188.86 | 180.00 | 0.00 | |
LOBBY_FLR_1_WALL_1_NORTH | NONRES_EXT_WALL_GRD | 0.30 | 0.846 | 0.969 | 213.77 | 209.87 | 0.00 | 90.00 | N |
LOBBY_FLR_1_WALL_2_NORTH | NONRES_EXT_WALL_GRD | 0.30 | 0.846 | 0.969 | 12.08 | 12.08 | 0.00 | 90.00 | N |
LOBBY_FLR_1_WALL_1_SOUTH | NONRES_EXT_WALL_GRD | 0.30 | 0.846 | 0.969 | 167.88 | 82.79 | 180.00 | 90.00 | S |
LOBBY_FLR_1_WALL_1_WEST | NONRES_EXT_WALL_GRD | 0.30 | 0.846 | 0.969 | 41.06 | 41.06 | 270.00 | 90.00 | W |
LOBBY_FLR_1_CEILING_2 | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 245.35 | 245.35 | 180.00 | 0.00 | |
ROOM_1_FLR_3_WALL_SOUTH | RES_EXT_WALL_MID | 0.30 | 1.029 | 1.217 | 55.74 | 37.35 | 180.00 | 90.00 | S |
ROOM_1_FLR_3_WALL_WEST | RES_EXT_WALL_MID | 0.30 | 1.029 | 1.217 | 104.06 | 69.72 | 270.00 | 90.00 | W |
ROOM_2_FLR_3_WALL_NORTH | RES_EXT_WALL_MID | 0.30 | 1.029 | 1.217 | 55.74 | 37.35 | 0.00 | 90.00 | N |
ROOM_2_FLR_3_WALL_WEST | RES_EXT_WALL_MID | 0.30 | 1.029 | 1.217 | 104.05 | 69.71 | 270.00 | 90.00 | W |
ROOM_3_MULT19_FLR_3_WALL_SOUTH | RES_EXT_WALL_MID | 0.30 | 1.029 | 1.217 | 847.14 | 567.58 | 180.00 | 90.00 | S |
ROOM_4_MULT19_FLR_3_WALL_NORTH | RES_EXT_WALL_MID | 0.30 | 1.029 | 1.217 | 847.37 | 567.71 | 0.00 | 90.00 | N |
ROOM_5_FLR_3_WALL_EAST | RES_EXT_WALL_MID | 0.30 | 1.029 | 1.217 | 104.06 | 69.72 | 90.00 | 90.00 | E |
ROOM_5_FLR_3_WALL_SOUTH | RES_EXT_WALL_MID | 0.30 | 1.029 | 1.217 | 55.74 | 37.35 | 180.00 | 90.00 | S |
ROOM_6_FLR_3_WALL_NORTH | RES_EXT_WALL_MID | 0.30 | 1.029 | 1.217 | 55.74 | 37.35 | 0.00 | 90.00 | N |
ROOM_6_FLR_3_WALL_EAST | RES_EXT_WALL_MID | 0.30 | 1.029 | 1.217 | 104.05 | 69.71 | 90.00 | 90.00 | E |
CORRIDOR_FLR_3_WALL_1_NORTH | NONRES_EXT_WALL_MID | 0.30 | 1.063 | 1.265 | 70.60 | 47.31 | 0.00 | 90.00 | N |
CORRIDOR_FLR_3_WALL_2_NORTH | NONRES_EXT_WALL_MID | 0.30 | 1.063 | 1.265 | 26.01 | 17.42 | 0.00 | 90.00 | N |
CORRIDOR_FLR_3_WALL_1_SOUTH | NONRES_EXT_WALL_MID | 0.30 | 1.063 | 1.265 | 26.02 | 17.43 | 180.00 | 90.00 | S |
CORRIDOR_FLR_3_WALL_2_SOUTH | NONRES_EXT_WALL_MID | 0.30 | 1.063 | 1.265 | 70.60 | 47.31 | 180.00 | 90.00 | S |
ROOM_1_FLR_6_WALL_SOUTH | RES_EXT_WALL_TOP | 0.30 | 1.078 | 1.286 | 13.94 | 9.34 | 180.00 | 90.00 | S |
ROOM_1_FLR_6_WALL_WEST | RES_EXT_WALL_TOP | 0.30 | 1.078 | 1.286 | 26.01 | 17.43 | 270.00 | 90.00 | W |
ROOM_1_FLR_6_CEILING | RES_ROOF | 0.55 | 0.273 | 0.283 | 39.02 | 39.02 | 180.00 | 0.00 | |
ROOM_2_FLR_6_WALL_NORTH | RES_EXT_WALL_TOP | 0.30 | 1.078 | 1.286 | 13.94 | 9.34 | 0.00 | 90.00 | N |
ROOM_2_FLR_6_WALL_WEST | RES_EXT_WALL_TOP | 0.30 | 1.078 | 1.286 | 26.01 | 17.43 | 270.00 | 90.00 | W |
ROOM_2_FLR_6_CEILING | RES_ROOF | 0.55 | 0.273 | 0.283 | 39.02 | 39.02 | 180.00 | 0.00 | |
ROOM_3_MULT9_FLR_6_WALL_SOUTH | RES_EXT_WALL_TOP | 0.30 | 1.078 | 1.286 | 183.96 | 123.26 | 180.00 | 90.00 | S |
ROOM_3_MULT9_FLR_6_CEILING | RES_ROOF | 0.55 | 0.273 | 0.283 | 220.77 | 220.77 | 180.00 | 0.00 | |
BANQUET_FLR_6_WALL_NORTH | NONRES_EXT_WALL_TOP | 0.30 | 1.112 | 1.335 | 97.55 | 65.36 | 0.00 | 90.00 | N |
BANQUET_FLR_6_CEILING | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 331.66 | 331.66 | 180.00 | 0.00 | |
DINING_FLR_6_WALL_NORTH | NONRES_EXT_WALL_TOP | 0.30 | 1.112 | 1.335 | 97.55 | 65.36 | 0.00 | 90.00 | N |
DINING_FLR_6_CEILING | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 331.66 | 331.66 | 180.00 | 0.00 | |
KITCHEN_FLR_6_WALL_NORTH | NONRES_EXT_WALL_TOP | 0.30 | 1.112 | 1.335 | 21.37 | 16.77 | 0.00 | 90.00 | N |
KITCHEN_FLR_6_WALL_EAST | NONRES_EXT_WALL_TOP | 0.30 | 1.112 | 1.335 | 52.03 | 34.86 | 90.00 | 90.00 | E |
KITCHEN_FLR_6_WALL_1_SOUTH | NONRES_EXT_WALL_TOP | 0.30 | 1.112 | 1.335 | 13.94 | 9.34 | 180.00 | 90.00 | S |
KITCHEN_FLR_6_CEILING | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 103.30 | 103.30 | 270.00 | 0.00 | |
CORRIDOR_FLR_6_WALL_1_NORTH | NONRES_EXT_WALL_TOP | 0.30 | 1.112 | 1.335 | 17.65 | 11.83 | 0.00 | 90.00 | N |
CORRIDOR_FLR_6_WALL_2_NORTH | NONRES_EXT_WALL_TOP | 0.30 | 1.112 | 1.335 | 15.79 | 10.58 | 0.00 | 90.00 | N |
CORRIDOR_FLR_6_WALL_2_SOUTH | NONRES_EXT_WALL_TOP | 0.30 | 1.112 | 1.335 | 52.03 | 34.86 | 180.00 | 90.00 | S |
CORRIDOR_FLR_6_CEILING_1 | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 244.71 | 244.71 | 90.00 | 0.00 | |
CORRIDOR_FLR_6_CEILING_2 | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 167.42 | 167.42 | 270.00 | 0.00 |
Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
BASEMENT_FLOOR | BASEMENT_FLOOR | 0.30 | 1.441 | 2.705 | 1978.83 | 1978.83 | 0.00 | 180.00 | |
BASEMENT_CEILING_1 | NONRES_FLOOR_CEILING | 0.30 | 0.186 | 0.196 | 67.07 | 67.07 | 180.00 | 0.00 | |
BASEMENT_CEILING_2 | NONRES_FLOOR_CEILING | 0.30 | 0.186 | 0.196 | 77.67 | 77.67 | 180.00 | 0.00 | |
BASEMENT_CEILING_3 | NONRES_FLOOR_CEILING | 0.30 | 0.186 | 0.196 | 164.24 | 164.24 | 180.00 | 0.00 | |
BASEMENT_CEILING_4 | NONRES_FLOOR_CEILING | 0.30 | 0.186 | 0.196 | 94.76 | 94.76 | 180.00 | 0.00 | |
BASEMENT_CEILING_5 | NONRES_FLOOR_CEILING | 0.30 | 0.186 | 0.196 | 78.04 | 78.04 | 180.00 | 0.00 | |
BASEMENT_CEILING_6 | NONRES_FLOOR_CEILING | 0.30 | 0.186 | 0.196 | 188.86 | 188.86 | 180.00 | 0.00 | |
BASEMENT_CEILING_7 | NONRES_FLOOR_CEILING | 0.30 | 0.186 | 0.196 | 1088.56 | 1088.56 | 180.00 | 0.00 | |
BASEMENT_CEILING_8 | NONRES_FLOOR_CEILING | 0.30 | 0.186 | 0.196 | 219.63 | 219.63 | 90.00 | 0.00 | |
RETAIL_1_FLR_1_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 45.89 | 45.89 | 0.00 | 90.00 | N |
RETAIL_1_FLR_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 22.95 | 22.95 | 90.00 | 90.00 | E |
RETAIL_1_FLR_1_FLOOR | NONRES_FLOOR | 0.30 | 0.186 | 0.196 | 67.07 | 67.07 | 0.00 | 180.00 | |
RETAIL_2_FLR_1_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 45.89 | 45.89 | 180.00 | 90.00 | S |
RETAIL_2_FLR_1_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 45.89 | 45.89 | 0.00 | 90.00 | N |
RETAIL_2_FLR_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 26.57 | 26.57 | 90.00 | 90.00 | E |
RETAIL_2_FLR_1_FLOOR | NONRES_FLOOR | 0.30 | 0.186 | 0.196 | 77.67 | 77.67 | 0.00 | 180.00 | |
RETAIL_2_FLR_1_CEILING | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 77.67 | 77.67 | 180.00 | 0.00 | |
MECH_FLR_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 41.06 | 41.06 | 90.00 | 90.00 | E |
MECH_FLR_1_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 62.80 | 62.80 | 180.00 | 90.00 | S |
MECH_FLR_1_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 41.06 | 41.06 | 270.00 | 90.00 | W |
MECH_FLR_1_FLOOR | NONRES_FLOOR | 0.30 | 0.186 | 0.196 | 164.24 | 164.24 | 0.00 | 180.00 | |
MECH_FLR_1_CEILING | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 164.24 | 164.24 | 180.00 | 0.00 | |
STORAGE_FLR_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 41.06 | 41.06 | 90.00 | 90.00 | E |
STORAGE_FLR_1_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 36.23 | 36.23 | 180.00 | 90.00 | S |
STORAGE_FLR_1_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 41.06 | 41.06 | 270.00 | 90.00 | W |
STORAGE_FLR_1_FLOOR | NONRES_FLOOR | 0.30 | 0.186 | 0.196 | 94.76 | 94.76 | 0.00 | 180.00 | |
STORAGE_FLR_1_CEILING | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 94.76 | 94.76 | 180.00 | 0.00 | |
LAUNDRY_FLR_1_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 18.12 | 18.12 | 180.00 | 90.00 | S |
LAUNDRY_FLR_1_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 67.63 | 67.63 | 270.00 | 90.00 | W |
LAUNDRY_FLR_1_FLOOR | NONRES_FLOOR | 0.30 | 0.186 | 0.196 | 78.04 | 78.04 | 0.00 | 180.00 | |
LAUNDRY_FLR_1_CEILING | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 78.04 | 78.04 | 180.00 | 0.00 | |
CAFE_FLR_1_WALL_1_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.11 | 111.11 | 0.00 | 90.00 | N |
CAFE_FLR_1_WALL_2_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 18.12 | 18.12 | 0.00 | 90.00 | N |
CAFE_FLR_1_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 22.95 | 22.95 | 270.00 | 90.00 | W |
CAFE_FLR_1_FLOOR | NONRES_FLOOR | 0.30 | 0.186 | 0.196 | 188.86 | 188.86 | 0.00 | 180.00 | |
LOBBY_FLR_1_WALL_2_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 45.89 | 45.89 | 180.00 | 90.00 | S |
LOBBY_FLR_1_WALL_3_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.11 | 111.11 | 180.00 | 90.00 | S |
LOBBY_FLR_1_WALL_2_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 22.95 | 22.95 | 270.00 | 90.00 | W |
LOBBY_FLR_1_WALL_3_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 26.57 | 26.57 | 270.00 | 90.00 | W |
LOBBY_FLR_1_WALL_4_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 41.06 | 41.06 | 270.00 | 90.00 | W |
LOBBY_FLR_1_WALL_3_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 62.80 | 62.80 | 0.00 | 90.00 | N |
LOBBY_FLR_1_WALL_4_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 36.23 | 36.23 | 0.00 | 90.00 | N |
LOBBY_FLR_1_WALL_1_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 41.06 | 41.06 | 90.00 | 90.00 | E |
LOBBY_FLR_1_WALL_2_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 22.95 | 22.95 | 90.00 | 90.00 | E |
LOBBY_FLR_1_WALL_3_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 67.63 | 67.63 | 90.00 | 90.00 | E |
LOBBY_FLR_1_FLOOR_1 | NONRES_FLOOR | 0.30 | 0.186 | 0.196 | 1088.56 | 1088.56 | 180.00 | 180.00 | |
LOBBY_FLR_1_FLOOR_2 | NONRES_FLOOR | 0.30 | 0.186 | 0.196 | 219.63 | 219.63 | 90.00 | 180.00 | |
LOBBY_FLR_1_CEILING_1 | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 1062.83 | 1062.83 | 270.00 | 0.00 | |
ROOM_1_FLR_3_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 55.74 | 55.74 | 0.00 | 90.00 | N |
ROOM_1_FLR_3_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 104.06 | 104.06 | 90.00 | 90.00 | E |
ROOM_1_FLR_3_FLOOR | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 156.09 | 156.09 | 0.00 | 180.00 | |
ROOM_1_FLR_3_CEILING | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 156.09 | 156.09 | 180.00 | 0.00 | |
ROOM_2_FLR_3_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 104.05 | 104.05 | 90.00 | 90.00 | E |
ROOM_2_FLR_3_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 55.74 | 55.74 | 180.00 | 90.00 | S |
ROOM_2_FLR_3_FLOOR | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 156.07 | 156.07 | 0.00 | 180.00 | |
ROOM_2_FLR_3_CEILING | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 156.07 | 156.07 | 180.00 | 0.00 | |
ROOM_3_MULT19_FLR_3_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 847.14 | 847.14 | 0.00 | 90.00 | N |
ROOM_3_MULT19_FLR_3_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 1553.43 | 1553.43 | 90.00 | 90.00 | E |
ROOM_3_MULT19_FLR_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 1553.43 | 1553.43 | 270.00 | 90.00 | W |
ROOM_3_MULT19_FLR_3_FLOOR | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 1863.81 | 1863.81 | 0.00 | 180.00 | |
ROOM_3_MULT19_FLR_3_CEILING | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 1863.81 | 1863.81 | 180.00 | 0.00 | |
ROOM_4_MULT19_FLR_3_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 1553.43 | 1553.43 | 90.00 | 90.00 | E |
ROOM_4_MULT19_FLR_3_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 847.37 | 847.37 | 180.00 | 90.00 | S |
ROOM_4_MULT19_FLR_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 1553.43 | 1553.43 | 270.00 | 90.00 | W |
ROOM_4_MULT19_FLR_3_FLOOR | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 1864.32 | 1864.32 | 0.00 | 180.00 | |
ROOM_4_MULT19_FLR_3_CEILING | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 1864.32 | 1864.32 | 180.00 | 0.00 | |
ROOM_5_FLR_3_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 55.74 | 55.74 | 0.00 | 90.00 | N |
ROOM_5_FLR_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 104.06 | 104.06 | 270.00 | 90.00 | W |
ROOM_5_FLR_3_FLOOR | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 156.09 | 156.09 | 0.00 | 180.00 | |
ROOM_5_FLR_3_CEILING | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 156.09 | 156.09 | 180.00 | 0.00 | |
ROOM_6_FLR_3_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 55.74 | 55.74 | 180.00 | 90.00 | S |
ROOM_6_FLR_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 104.05 | 104.05 | 270.00 | 90.00 | W |
ROOM_6_FLR_3_FLOOR | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 156.07 | 156.07 | 0.00 | 180.00 | |
ROOM_6_FLR_3_CEILING | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 156.07 | 156.07 | 180.00 | 0.00 | |
CORRIDOR_FLR_3_WALL_3_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 847.28 | 847.28 | 0.00 | 90.00 | N |
CORRIDOR_FLR_3_WALL_1_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 81.76 | 81.76 | 90.00 | 90.00 | E |
CORRIDOR_FLR_3_WALL_2_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 81.76 | 81.76 | 90.00 | 90.00 | E |
CORRIDOR_FLR_3_WALL_3_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 104.06 | 104.06 | 90.00 | 90.00 | E |
CORRIDOR_FLR_3_WALL_4_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 104.05 | 104.05 | 90.00 | 90.00 | E |
CORRIDOR_FLR_3_WALL_3_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 847.27 | 847.27 | 180.00 | 90.00 | S |
CORRIDOR_FLR_3_WALL_1_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 81.76 | 81.76 | 270.00 | 90.00 | W |
CORRIDOR_FLR_3_WALL_2_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 81.76 | 81.76 | 270.00 | 90.00 | W |
CORRIDOR_FLR_3_WALL_3_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 104.06 | 104.06 | 270.00 | 90.00 | W |
CORRIDOR_FLR_3_WALL_4_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 104.05 | 104.05 | 270.00 | 90.00 | W |
CORRIDOR_FLR_3_FLOOR_1 | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 297.29 | 297.29 | 180.00 | 180.00 | |
CORRIDOR_FLR_3_FLOOR_2 | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 963.06 | 963.06 | 270.00 | 180.00 | |
CORRIDOR_FLR_3_FLOOR_3 | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 297.26 | 297.26 | 90.00 | 180.00 | |
CORRIDOR_FLR_3_CEILING_1 | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 297.29 | 297.29 | 90.00 | 0.00 | |
CORRIDOR_FLR_3_CEILING_2 | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 963.06 | 963.06 | 90.00 | 0.00 | |
CORRIDOR_FLR_3_CEILING_3 | NONRES_FLOOR_CEILING | 0.30 | 0.188 | 0.196 | 297.26 | 297.26 | 90.00 | 0.00 | |
ROOM_1_FLR_6_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 13.94 | 13.94 | 0.00 | 90.00 | N |
ROOM_1_FLR_6_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 26.01 | 26.01 | 90.00 | 90.00 | E |
ROOM_1_FLR_6_FLOOR | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 39.02 | 39.02 | 0.00 | 180.00 | |
ROOM_2_FLR_6_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 26.01 | 26.01 | 90.00 | 90.00 | E |
ROOM_2_FLR_6_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 13.94 | 13.94 | 180.00 | 90.00 | S |
ROOM_2_FLR_6_FLOOR | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 39.02 | 39.02 | 0.00 | 180.00 | |
ROOM_3_MULT9_FLR_6_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 183.96 | 183.96 | 0.00 | 90.00 | N |
ROOM_3_MULT9_FLR_6_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 100.35 | 100.35 | 90.00 | 90.00 | E |
ROOM_3_MULT9_FLR_6_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 100.35 | 100.35 | 270.00 | 90.00 | W |
ROOM_3_MULT9_FLR_6_FLOOR | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 220.77 | 220.77 | 0.00 | 180.00 | |
BANQUET_FLR_6_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 31.59 | 31.59 | 90.00 | 90.00 | E |
BANQUET_FLR_6_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 97.55 | 97.55 | 180.00 | 90.00 | S |
BANQUET_FLR_6_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 31.59 | 31.59 | 270.00 | 90.00 | W |
BANQUET_FLR_6_FLOOR | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 331.66 | 331.66 | 0.00 | 180.00 | |
DINING_FLR_6_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 31.59 | 31.59 | 90.00 | 90.00 | E |
DINING_FLR_6_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 97.55 | 97.55 | 180.00 | 90.00 | S |
DINING_FLR_6_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 31.59 | 31.59 | 270.00 | 90.00 | W |
DINING_FLR_6_FLOOR | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 331.66 | 331.66 | 0.00 | 180.00 | |
KITCHEN_FLR_6_WALL_2_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 7.43 | 7.43 | 180.00 | 90.00 | S |
KITCHEN_FLR_6_WALL_1_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 20.44 | 20.44 | 270.00 | 90.00 | W |
KITCHEN_FLR_6_WALL_2_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 31.59 | 31.59 | 270.00 | 90.00 | W |
KITCHEN_FLR_6_FLOOR | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 103.30 | 103.30 | 180.00 | 180.00 | |
CORRIDOR_FLR_6_WALL_3_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 97.55 | 97.55 | 0.00 | 90.00 | N |
CORRIDOR_FLR_6_WALL_4_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 104.98 | 104.98 | 0.00 | 90.00 | N |
CORRIDOR_FLR_6_WALL_1_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 183.95 | 183.95 | 180.00 | 90.00 | S |
CORRIDOR_FLR_6_WALL_1_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 11.15 | 11.15 | 270.00 | 90.00 | W |
CORRIDOR_FLR_6_WALL_2_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 40.88 | 40.88 | 270.00 | 90.00 | W |
CORRIDOR_FLR_6_WALL_3_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 31.59 | 31.59 | 270.00 | 90.00 | W |
CORRIDOR_FLR_6_WALL_1_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 31.59 | 31.59 | 90.00 | 90.00 | E |
CORRIDOR_FLR_6_WALL_2_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 31.59 | 31.59 | 90.00 | 90.00 | E |
CORRIDOR_FLR_6_WALL_3_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 20.44 | 20.44 | 90.00 | 90.00 | E |
CORRIDOR_FLR_6_FLOOR | NONRES_FLOOR | 0.30 | 0.185 | 0.196 | 412.12 | 412.12 | 180.00 | 180.00 | |
BASEMENT_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 3957.66 | 0.00 | 90.00 | N | ||
RETAIL_1_FLR_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 134.14 | 0.00 | 90.00 | N | ||
RETAIL_2_FLR_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 155.34 | 0.00 | 90.00 | N | ||
MECH_FLR_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 328.49 | 0.00 | 90.00 | N | ||
STORAGE_FLR_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 189.52 | 0.00 | 90.00 | N | ||
LAUNDRY_FLR_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 156.08 | 0.00 | 90.00 | N | ||
CAFE_FLR_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 377.72 | 0.00 | 90.00 | N | ||
LOBBY_FLR_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 2616.37 | 0.00 | 90.00 | N | ||
ROOM_1_FLR_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 312.18 | 0.00 | 90.00 | N | ||
ROOM_2_FLR_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 312.14 | 0.00 | 90.00 | N | ||
ROOM_3_MULT19_FLR_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 3727.63 | 0.00 | 90.00 | N | ||
ROOM_4_MULT19_FLR_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 3728.64 | 0.00 | 90.00 | N | ||
ROOM_5_FLR_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 312.18 | 0.00 | 90.00 | N | ||
ROOM_6_FLR_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 312.14 | 0.00 | 90.00 | N | ||
CORRIDOR_FLR_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 3115.24 | 0.00 | 90.00 | N | ||
ROOM_1_FLR_6_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 78.04 | 0.00 | 90.00 | N | ||
ROOM_2_FLR_6_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 78.03 | 0.00 | 90.00 | N | ||
ROOM_3_MULT9_FLR_6_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 441.55 | 0.00 | 90.00 | N | ||
BANQUET_FLR_6_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 663.31 | 0.00 | 90.00 | N | ||
DINING_FLR_6_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 663.31 | 0.00 | 90.00 | N | ||
KITCHEN_FLR_6_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 206.61 | 0.00 | 90.00 | N | ||
CORRIDOR_FLR_6_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 824.25 | 0.00 | 90.00 | N |
Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
RETAIL_1_FLR_1_WALL_SOUTH_WINDOW | NONRESWINDOW_U_0.4711_SHGC_0.25 | 23.26 | 0.00 | 0.00 | 23.26 | 23.26 | 2.678 | 0.251 | 0.251 | No | RETAIL_1_FLR_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
CAFE_FLR_1_WALL_SOUTH_WINDOW | NONRESWINDOW_U_0.4711_SHGC_0.25 | 65.50 | 0.00 | 0.00 | 65.50 | 65.50 | 2.678 | 0.251 | 0.251 | No | CAFE_FLR_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
LOBBY_FLR_1_WALL_SOUTH_WINDOW | NONRESWINDOW_U_0.4711_SHGC_0.25 | 85.08 | 0.00 | 0.00 | 85.08 | 85.08 | 2.678 | 0.251 | 0.251 | No | LOBBY_FLR_1_WALL_1_SOUTH | 180.00 | 90.00 | S | |||||||
ROOM_1_FLR_3_WALL_SOUTH_WINDOW | RESWINDOW_U_0.4711_SHGC_0.25 | 4.60 | 0.00 | 0.00 | 4.60 | 18.40 | 2.678 | 0.251 | 0.251 | No | ROOM_1_FLR_3_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
ROOM_1_FLR_3_WALL_WEST_WINDOW | RESWINDOW_U_0.4711_SHGC_0.25 | 8.58 | 0.00 | 0.00 | 8.58 | 34.34 | 2.678 | 0.251 | 0.251 | No | ROOM_1_FLR_3_WALL_WEST | 270.00 | 90.00 | W | |||||||
ROOM_2_FLR_3_WALL_NORTH_WINDOW | RESWINDOW_U_0.4711_SHGC_0.25 | 4.60 | 0.00 | 0.00 | 4.60 | 18.40 | 2.678 | 0.251 | 0.251 | No | ROOM_2_FLR_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
ROOM_2_FLR_3_WALL_WEST_WINDOW | RESWINDOW_U_0.4711_SHGC_0.25 | 8.58 | 0.00 | 0.00 | 8.58 | 34.34 | 2.678 | 0.251 | 0.251 | No | ROOM_2_FLR_3_WALL_WEST | 270.00 | 90.00 | W | |||||||
ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW | RESWINDOW_U_0.4711_SHGC_0.25 | 3.68 | 0.00 | 0.00 | 3.68 | 279.56 | 2.678 | 0.251 | 0.251 | No | ROOM_3_MULT19_FLR_3_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW | RESWINDOW_U_0.4711_SHGC_0.25 | 3.68 | 0.00 | 0.00 | 3.68 | 279.65 | 2.678 | 0.251 | 0.251 | No | ROOM_4_MULT19_FLR_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
ROOM_5_FLR_3_WALL_EAST_WINDOW | RESWINDOW_U_0.4711_SHGC_0.25 | 8.58 | 0.00 | 0.00 | 8.58 | 34.34 | 2.678 | 0.251 | 0.251 | No | ROOM_5_FLR_3_WALL_EAST | 90.00 | 90.00 | E | |||||||
ROOM_5_FLR_3_WALL_SOUTH_WINDOW | RESWINDOW_U_0.4711_SHGC_0.25 | 4.60 | 0.00 | 0.00 | 4.60 | 18.40 | 2.678 | 0.251 | 0.251 | No | ROOM_5_FLR_3_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
ROOM_6_FLR_3_WALL_NORTH_WINDOW | RESWINDOW_U_0.4711_SHGC_0.25 | 4.60 | 0.00 | 0.00 | 4.60 | 18.40 | 2.678 | 0.251 | 0.251 | No | ROOM_6_FLR_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
ROOM_6_FLR_3_WALL_EAST_WINDOW | RESWINDOW_U_0.4711_SHGC_0.25 | 8.58 | 0.00 | 0.00 | 8.58 | 34.34 | 2.678 | 0.251 | 0.251 | No | ROOM_6_FLR_3_WALL_EAST | 90.00 | 90.00 | E | |||||||
CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW | NONRESWINDOW_U_0.4711_SHGC_0.25 | 5.82 | 0.00 | 0.00 | 5.82 | 23.30 | 2.678 | 0.251 | 0.251 | No | CORRIDOR_FLR_3_WALL_1_NORTH | 0.00 | 90.00 | N | |||||||
CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW | NONRESWINDOW_U_0.4711_SHGC_0.25 | 2.15 | 0.00 | 0.00 | 2.15 | 8.59 | 2.678 | 0.251 | 0.251 | No | CORRIDOR_FLR_3_WALL_2_NORTH | 0.00 | 90.00 | N | |||||||
CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW | NONRESWINDOW_U_0.4711_SHGC_0.25 | 2.15 | 0.00 | 0.00 | 2.15 | 8.58 | 2.678 | 0.251 | 0.251 | No | CORRIDOR_FLR_3_WALL_1_SOUTH | 180.00 | 90.00 | S | |||||||
CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW | NONRESWINDOW_U_0.4711_SHGC_0.25 | 5.82 | 0.00 | 0.00 | 5.82 | 23.30 | 2.678 | 0.251 | 0.251 | No | CORRIDOR_FLR_3_WALL_2_SOUTH | 180.00 | 90.00 | S | |||||||
ROOM_1_FLR_6_WALL_SOUTH_WINDOW | RESWINDOW_U_0.4711_SHGC_0.25 | 4.60 | 0.00 | 0.00 | 4.60 | 4.60 | 2.678 | 0.251 | 0.251 | No | ROOM_1_FLR_6_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
ROOM_1_FLR_6_WALL_WEST_WINDOW | RESWINDOW_U_0.4711_SHGC_0.25 | 8.58 | 0.00 | 0.00 | 8.58 | 8.58 | 2.678 | 0.251 | 0.251 | No | ROOM_1_FLR_6_WALL_WEST | 270.00 | 90.00 | W | |||||||
ROOM_2_FLR_6_WALL_NORTH_WINDOW | RESWINDOW_U_0.4711_SHGC_0.25 | 4.60 | 0.00 | 0.00 | 4.60 | 4.60 | 2.678 | 0.251 | 0.251 | No | ROOM_2_FLR_6_WALL_NORTH | 0.00 | 90.00 | N | |||||||
ROOM_2_FLR_6_WALL_WEST_WINDOW | RESWINDOW_U_0.4711_SHGC_0.25 | 8.58 | 0.00 | 0.00 | 8.58 | 8.58 | 2.678 | 0.251 | 0.251 | No | ROOM_2_FLR_6_WALL_WEST | 270.00 | 90.00 | W | |||||||
ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW | RESWINDOW_U_0.4711_SHGC_0.25 | 6.74 | 0.00 | 0.00 | 6.74 | 60.70 | 2.678 | 0.251 | 0.251 | No | ROOM_3_MULT9_FLR_6_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
BANQUET_FLR_6_WALL_NORTH_WINDOW | NONRESWINDOW_U_0.4711_SHGC_0.25 | 32.19 | 0.00 | 0.00 | 32.19 | 32.19 | 2.678 | 0.251 | 0.251 | No | BANQUET_FLR_6_WALL_NORTH | 0.00 | 90.00 | N | |||||||
DINING_FLR_6_WALL_NORTH_WINDOW | NONRESWINDOW_U_0.4711_SHGC_0.25 | 32.19 | 0.00 | 0.00 | 32.19 | 32.19 | 2.678 | 0.251 | 0.251 | No | DINING_FLR_6_WALL_NORTH | 0.00 | 90.00 | N | |||||||
KITCHEN_FLR_6_WALL_NORTH_WINDOW | NONRESWINDOW_U_0.4711_SHGC_0.25 | 4.60 | 0.00 | 0.00 | 4.60 | 4.60 | 2.678 | 0.251 | 0.251 | No | KITCHEN_FLR_6_WALL_NORTH | 0.00 | 90.00 | N | |||||||
KITCHEN_FLR_6_WALL_EAST_WINDOW | NONRESWINDOW_U_0.4711_SHGC_0.25 | 17.17 | 0.00 | 0.00 | 17.17 | 17.17 | 2.678 | 0.251 | 0.251 | No | KITCHEN_FLR_6_WALL_EAST | 90.00 | 90.00 | E | |||||||
KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW | NONRESWINDOW_U_0.4711_SHGC_0.25 | 4.60 | 0.00 | 0.00 | 4.60 | 4.60 | 2.678 | 0.251 | 0.251 | No | KITCHEN_FLR_6_WALL_1_SOUTH | 180.00 | 90.00 | S | |||||||
CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW | NONRESWINDOW_U_0.4711_SHGC_0.25 | 5.82 | 0.00 | 0.00 | 5.82 | 5.82 | 2.678 | 0.251 | 0.251 | No | CORRIDOR_FLR_6_WALL_1_NORTH | 0.00 | 90.00 | N | |||||||
CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW | NONRESWINDOW_U_0.4711_SHGC_0.25 | 5.21 | 0.00 | 0.00 | 5.21 | 5.21 | 2.678 | 0.251 | 0.251 | No | CORRIDOR_FLR_6_WALL_2_NORTH | 0.00 | 90.00 | N | |||||||
CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW | NONRESWINDOW_U_0.4711_SHGC_0.25 | 17.17 | 0.00 | 0.00 | 17.17 | 17.17 | 2.678 | 0.251 | 0.251 | No | CORRIDOR_FLR_6_WALL_2_SOUTH | 180.00 | 90.00 | S | |||||||
Total or Average | 1213.79 | 2.678 | 0.251 | 0.251 | |||||||||||||||||
North Total or Average | 432.95 | 2.678 | 0.251 | 0.251 | |||||||||||||||||
Non-North Total or Average | 780.84 | 2.678 | 0.251 | 0.251 |
Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
None |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
RETAIL_2_FLR_1_WALL_WEST_DOOR | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | RETAIL_2_FLR_1_WALL_WEST |
STORAGE_FLR_1_WALL_NORTH_ROLLDOOR | OVERHEAD DOOR_CON | 1.016 | 1.198 | 7.43 | STORAGE_FLR_1_WALL_NORTH |
LAUNDRY_FLR_1_WALL_EAST_DOOR | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | LAUNDRY_FLR_1_WALL_EAST |
CAFE_FLR_1_WALL_EAST_DOOR | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | CAFE_FLR_1_WALL_EAST |
LOBBY_FLR_1_WALL_1_NORTH_DOOR1 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | LOBBY_FLR_1_WALL_1_NORTH |
LOBBY_FLR_1_WALL_1_NORTH_DOOR2 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | LOBBY_FLR_1_WALL_1_NORTH |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
RETAIL_1_FLR_1_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
CAFE_FLR_1_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LOBBY_FLR_1_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
ROOM_1_FLR_3_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
ROOM_1_FLR_3_WALL_WEST_WINDOW | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
ROOM_2_FLR_3_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_3_WALL_WEST_WINDOW | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_5_FLR_3_WALL_EAST_WINDOW | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
ROOM_5_FLR_3_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
ROOM_6_FLR_3_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_6_FLR_3_WALL_EAST_WINDOW | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
ROOM_1_FLR_6_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
ROOM_1_FLR_6_WALL_WEST_WINDOW | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
ROOM_2_FLR_6_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_6_WALL_WEST_WINDOW | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
BANQUET_FLR_6_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
DINING_FLR_6_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
KITCHEN_FLR_6_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
KITCHEN_FLR_6_WALL_EAST_WINDOW | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
Interior LightingZone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
BASEMENT_LIGHTS | BASEMENT | BASEMENT | GENERAL | 8.7495 | 1978.83 | 17313.73 | LightsWired | LTG_SCH_BASEMENT | 50.91 | 168.00 | 50.86 | 0.0000 | Y | 165.29 |
RETAIL_1_FLR_1_LIGHTS | RETAIL_1_FLR_1 | RETAIL_1_FLR_1 | GENERAL | 13.0124 | 67.07 | 872.76 | LightsWired | LTG_SCH_RETAIL | 51.36 | 168.00 | 51.30 | 0.0000 | Y | 8.40 |
RETAIL_2_FLR_1_LIGHTS | RETAIL_2_FLR_1 | RETAIL_2_FLR_1 | GENERAL | 13.0124 | 77.67 | 1010.66 | LightsWired | LTG_SCH_RETAIL | 51.36 | 168.00 | 51.30 | 0.0000 | Y | 9.73 |
MECH_FLR_1_LIGHTS | MECH_FLR_1 | MECH_FLR_1 | GENERAL | 10.0642 | 164.24 | 1652.98 | LightsWired | LTG_SCH_MECHANIC | 58.69 | 168.00 | 58.63 | 0.0000 | Y | 18.19 |
STORAGE_FLR_1_LIGHTS | STORAGE_FLR_1 | STORAGE_FLR_1 | GENERAL | 7.3195 | 94.76 | 693.59 | LightsWired | LTG_SCH_STORAGE | 25.68 | 168.00 | 25.65 | 0.0000 | Y | 3.34 |
LAUNDRY_FLR_1_LIGHTS | LAUNDRY_FLR_1 | LAUNDRY_FLR_1 | GENERAL | 5.4896 | 78.04 | 428.40 | LightsWired | LTG_SCH_LAUNDRY | 51.36 | 168.00 | 51.30 | 0.0000 | Y | 4.13 |
CAFE_FLR_1_LIGHTS | CAFE_FLR_1 | CAFE_FLR_1 | GENERAL | 12.8090 | 188.86 | 2419.14 | LightsWired | LTG_SCH_DINING | 58.69 | 168.00 | 58.63 | 0.0000 | Y | 26.62 |
LOBBY_FLR_1_LIGHTS | LOBBY_FLR_1 | LOBBY_FLR_1 | GENERAL | 10.0642 | 1308.19 | 13165.91 | LightsWired | LTG_SCH_LOBBY | 58.69 | 168.00 | 58.63 | 0.0000 | Y | 144.89 |
ROOM_1_FLR_3_LIGHTS | ROOM_1_FLR_3 | ROOM_1_FLR_3 | GENERAL | 10.0642 | 156.09 | 1570.91 | LightsWired | LTG_SCH_GUESTROOM | 69.03 | 168.00 | 69.21 | 0.0000 | Y | 20.41 |
ROOM_2_FLR_3_LIGHTS | ROOM_2_FLR_3 | ROOM_2_FLR_3 | GENERAL | 10.0642 | 156.07 | 1570.72 | LightsWired | LTG_SCH_GUESTROOM | 69.03 | 168.00 | 69.21 | 0.0000 | Y | 20.41 |
ROOM_3_MULT19_FLR_3_LIGHTS | ROOM_3_MULT19_FLR_3 | ROOM_3_MULT19_FLR_3 | GENERAL | 10.0642 | 1863.81 | 18757.86 | LightsWired | LTG_SCH_GUESTROOM | 69.03 | 168.00 | 69.21 | 0.0000 | Y | 243.70 |
ROOM_4_MULT19_FLR_3_LIGHTS | ROOM_4_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | GENERAL | 10.0642 | 1864.32 | 18762.99 | LightsWired | LTG_SCH_GUESTROOM | 69.03 | 168.00 | 69.21 | 0.0000 | Y | 243.77 |
ROOM_5_FLR_3_LIGHTS | ROOM_5_FLR_3 | ROOM_5_FLR_3 | GENERAL | 10.0642 | 156.09 | 1570.91 | LightsWired | LTG_SCH_GUESTROOM | 69.03 | 168.00 | 69.21 | 0.0000 | Y | 20.41 |
ROOM_6_FLR_3_LIGHTS | ROOM_6_FLR_3 | ROOM_6_FLR_3 | GENERAL | 10.0642 | 156.07 | 1570.72 | LightsWired | LTG_SCH_GUESTROOM | 69.03 | 168.00 | 69.21 | 0.0000 | Y | 20.41 |
CORRIDOR_FLR_3_LIGHTS | CORRIDOR_FLR_3 | CORRIDOR_FLR_3 | GENERAL | 3.6597 | 1557.62 | 5700.46 | LightsWired | LTG_SCH_CORRIDOR | 58.69 | 168.00 | 58.63 | 0.0000 | Y | 62.73 |
ROOM_1_FLR_6_LIGHTS | ROOM_1_FLR_6 | ROOM_1_FLR_6 | GENERAL | 10.0642 | 39.02 | 392.73 | LightsWired | LTG_SCH_GUESTROOM | 69.03 | 168.00 | 69.21 | 0.0000 | Y | 5.10 |
ROOM_2_FLR_6_LIGHTS | ROOM_2_FLR_6 | ROOM_2_FLR_6 | GENERAL | 10.0642 | 39.02 | 392.68 | LightsWired | LTG_SCH_GUESTROOM | 69.03 | 168.00 | 69.21 | 0.0000 | Y | 5.10 |
ROOM_3_MULT9_FLR_6_LIGHTS | ROOM_3_MULT9_FLR_6 | ROOM_3_MULT9_FLR_6 | GENERAL | 10.0642 | 220.77 | 2221.93 | LightsWired | LTG_SCH_GUESTROOM | 69.03 | 168.00 | 69.21 | 0.0000 | Y | 28.87 |
BANQUET_FLR_6_LIGHTS | BANQUET_FLR_6 | BANQUET_FLR_6 | GENERAL | 12.8090 | 331.66 | 4248.21 | LightsWired | LTG_SCH_DINING | 58.69 | 168.00 | 58.63 | 0.0000 | Y | 46.75 |
DINING_FLR_6_LIGHTS | DINING_FLR_6 | DINING_FLR_6 | GENERAL | 12.8090 | 331.66 | 4248.21 | LightsWired | LTG_SCH_DINING | 58.69 | 168.00 | 58.63 | 0.0000 | Y | 46.75 |
KITCHEN_FLR_6_LIGHTS | KITCHEN_FLR_6 | KITCHEN_FLR_6 | GENERAL | 10.9792 | 103.30 | 1134.20 | LightsWired | LTG_SCH_KITCHEN | 58.69 | 168.00 | 58.63 | 0.0000 | Y | 12.48 |
CORRIDOR_FLR_6_LIGHTS | CORRIDOR_FLR_6 | CORRIDOR_FLR_6 | GENERAL | 3.6597 | 412.12 | 1508.26 | LightsWired | LTG_SCH_CORRIDOR | 58.69 | 168.00 | 58.63 | 0.0000 | Y | 16.60 |
Interior Lighting Total | 8.9207 | 11345.29 | 101207.97 | 559.10 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR FACADE LIGHTING | 16690.39 | AstronomicalClock | - | 83.77 | 83.77 | 262.45 | |
Exterior Lighting Total | 16690.39 | 262.45 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
Central PlantType | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
HEATSYS1 BOILER | Boiler:HotWater | 506723.24 | 0.80 | ||||
COOLSYS1 CHILLER1 | Chiller:Electric:EIR | 1342132.77 | 2.80 | 1342368.68 | 2.80 | 3.72 | 12.68 |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
ROOM_1_FLR_3 FAN COIL COOLING COIL | Coil:Cooling:Water | 13319.33 | 19427.65 | 14980.20 | 4447.45 | 0.77 | - | 2253.81 | 22.86 |
ROOM_2_FLR_3 FAN COIL COOLING COIL | Coil:Cooling:Water | 13180.00 | 19218.33 | 14815.76 | 4402.57 | 0.77 | - | 2229.37 | 22.61 |
ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | Coil:Cooling:Water | 80570.62 | 118565.73 | 91956.04 | 26609.69 | 0.78 | - | 13783.08 | 139.80 |
ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | Coil:Cooling:Water | 88705.77 | 128259.85 | 98350.36 | 29909.49 | 0.77 | - | 14852.36 | 150.64 |
ROOM_5_FLR_3 FAN COIL COOLING COIL | Coil:Cooling:Water | 12087.38 | 17582.20 | 13533.25 | 4048.95 | 0.77 | - | 2038.50 | 20.68 |
ROOM_6_FLR_3 FAN COIL COOLING COIL | Coil:Cooling:Water | 11984.44 | 17428.20 | 13412.61 | 4015.59 | 0.77 | - | 2020.54 | 20.49 |
ROOM_1_FLR_6 FAN COIL COOLING COIL | Coil:Cooling:Water | 3558.18 | 5198.61 | 4012.83 | 1185.78 | 0.77 | - | 603.32 | 6.12 |
ROOM_2_FLR_6 FAN COIL COOLING COIL | Coil:Cooling:Water | 3516.81 | 5136.55 | 3964.13 | 1172.43 | 0.77 | - | 596.07 | 6.05 |
ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL | Coil:Cooling:Water | 16548.41 | 24040.21 | 18488.90 | 5551.32 | 0.77 | - | 2786.50 | 28.26 |
VAV WITH REHEAT COOLING COIL | Coil:Cooling:Water | 1006896.45 | 713688.50 | 450069.74 | 263618.77 | 0.63 | - | 88202.28 | 894.60 |
FLR_3_DOAS COOLING COIL | Coil:Cooling:Water | 91161.11 | 64688.92 | 41041.02 | 23647.90 | 0.63 | - | 7608.06 | 77.17 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
None |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
None |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
BASEMENT VAV BOX REHEAT COIL | Coil:Heating:Water | 13901.20 | 13972.88 | - |
RETAIL_1_FLR_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 4933.80 | 4956.71 | - |
RETAIL_2_FLR_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 2338.12 | 2349.77 | - |
MECH_FLR_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 3349.56 | 3365.43 | - |
STORAGE_FLR_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 1871.32 | 1880.04 | - |
LAUNDRY_FLR_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 19827.68 | 19929.66 | - |
CAFE_FLR_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 15469.87 | 15544.88 | - |
LOBBY_FLR_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 43663.12 | 43881.28 | - |
ROOM_1_FLR_3 FAN COIL HEATING COIL | Coil:Heating:Water | 7185.55 | 7740.43 | - |
ROOM_2_FLR_3 FAN COIL HEATING COIL | Coil:Heating:Water | 7197.93 | 7753.77 | - |
ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL | Coil:Heating:Water | 40940.92 | 44102.37 | - |
ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL | Coil:Heating:Water | 41190.56 | 44371.24 | - |
ROOM_5_FLR_3 FAN COIL HEATING COIL | Coil:Heating:Water | 7159.97 | 7712.89 | - |
ROOM_6_FLR_3 FAN COIL HEATING COIL | Coil:Heating:Water | 7172.36 | 7726.24 | - |
CORRIDOR_FLR_3 VAV BOX REHEAT COIL | Coil:Heating:Water | 16907.37 | 16985.95 | - |
ROOM_1_FLR_6 FAN COIL HEATING COIL | Coil:Heating:Water | 2207.10 | 2377.44 | - |
ROOM_2_FLR_6 FAN COIL HEATING COIL | Coil:Heating:Water | 2212.04 | 2382.76 | - |
ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL | Coil:Heating:Water | 10571.41 | 11387.27 | - |
BANQUET_FLR_6 VAV BOX REHEAT COIL | Coil:Heating:Water | 19074.64 | 19170.64 | - |
DINING_FLR_6 VAV BOX REHEAT COIL | Coil:Heating:Water | 19787.81 | 19887.48 | - |
KITCHEN_FLR_6 VAV BOX REHEAT COIL | Coil:Heating:Water | 14213.11 | 14286.08 | - |
CORRIDOR_FLR_6 VAV BOX REHEAT COIL | Coil:Heating:Water | 11283.65 | 11335.45 | - |
VAV WITH REHEAT HEATING COIL | Coil:Heating:Water | 177751.76 | 132197.42 | - |
FLR_3_DOAS HEATING COIL | Coil:Heating:Water | 16512.40 | 12280.59 | - |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
LAUNDRY_FLR_1 EXHAUST FAN | Fan:ZoneExhaust | 0.16 | 125.00 | 0.24 | 184.35 | 781.25 | 1.00 | 1.15 | General | ||
LOBBY_FLR_1 EXHAUST FAN | Fan:ZoneExhaust | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | General | |||
ROOM_1_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.16 | 270.90 | 1.08 | 1826.87 | 1693.12 | 1.00 | 0.49 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:10:00 |
ROOM_2_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.16 | 270.90 | 1.07 | 1806.26 | 1693.12 | 1.00 | 0.49 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:20:00 |
ROOM_3_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.16 | 270.90 | 6.68 | 11313.62 | 1693.12 | 1.00 | 0.40 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:20:00 |
ROOM_4_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.16 | 270.90 | 7.02 | 11892.41 | 1693.12 | 1.00 | 0.39 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 |
ROOM_5_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.16 | 270.90 | 0.97 | 1645.96 | 1693.12 | 1.00 | 0.50 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:40:00 |
ROOM_6_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.16 | 270.90 | 0.96 | 1630.90 | 1693.12 | 1.00 | 0.50 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:20:00 |
ROOM_1_FLR_6 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.16 | 270.90 | 0.29 | 490.18 | 1693.12 | 1.00 | 0.72 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 |
ROOM_2_FLR_6 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.16 | 270.90 | 0.29 | 484.08 | 1693.12 | 1.00 | 0.73 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:10:00 |
ROOM_3_MULT9_FLR_6 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.16 | 270.90 | 1.33 | 2245.86 | 1693.12 | 1.00 | 0.47 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 |
BANQUET_FLR_6 EXHAUST FAN | Fan:ZoneExhaust | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | General | |||
DINING_FLR_6 EXHAUST FAN | Fan:ZoneExhaust | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | General | |||
KITCHEN_FLR_6 EXHAUST FAN | Fan:ZoneExhaust | 0.16 | 125.00 | 1.89 | 1474.84 | 781.25 | 1.00 | 0.62 | General | ||
VAV WITH REHEAT FAN | Fan:VariableVolume | 0.62 | 1389.42 | 22.08 | 49477.56 | 2240.64 | 1.00 | 1.11 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 |
FLR_3_DOAS FAN | Fan:ConstantVolume | 0.58 | 622.50 | 2.05 | 2194.93 | 1070.05 | 1.00 | 1.30 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
COOLSYS1 PUMP SECONDARY | Pump:VariableSpeed | Intermittent | 133527.72 | 0.047916 | 9873.74 | 206062.94 | 0.90 | General |
HEATSYS1 PUMP | Pump:VariableSpeed | Intermittent | 180705.70 | 0.004433 | 1335.04 | 301156.09 | 0.90 | General |
COOLSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 92445.74 | 0.047916 | 6835.92 | 142664.32 | 0.90 | General |
SWHSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 29891.00 | 0.000375 | 47.91 | 127739.32 | 0.30 | General |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SWH BOOSTER E WATER HEATER | WaterHeater:Mixed | 0.02 | 8000.00 | 1.00 | 1.24 | 1.15 |
SWH LAUNDRY G WATER HEATER | WaterHeater:Mixed | 1.14 | 163316.00 | 0.80 | 0.58 | 0.51 |
SWHSYS1 WATER HEATER | WaterHeater:Mixed | 2.27 | 175842.60 | 0.80 | 0.26 | 0.03 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BASEMENT | 33243.88 | 33243.88 | 16.80 | 2.505 | 2.505 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 20:50:00 | 24.00 | 24.00 | 0.00923 | 28.94 | 0.01446 | 0.854 | 0.00 |
RETAIL_1_FLR_1 | 4479.28 | 4479.28 | 66.78 | 0.338 | 0.338 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 24.00 | 24.00 | 0.00930 | 34.40 | 0.01447 | 0.079 | 0.00 |
RETAIL_2_FLR_1 | 3319.04 | 3319.04 | 42.73 | 0.250 | 0.250 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:40:00 | 24.00 | 24.00 | 0.00948 | 32.44 | 0.01447 | 0.092 | 0.00 |
MECH_FLR_1 | 3499.29 | 3499.29 | 21.31 | 0.264 | 0.264 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:40:00 | 24.00 | 24.00 | 0.00898 | 32.44 | 0.01447 | 0.000 | 0.00 |
STORAGE_FLR_1 | 1745.62 | 1745.62 | 18.42 | 0.132 | 0.132 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:50:00 | 24.00 | 24.00 | 0.00912 | 32.28 | 0.01447 | 0.058 | 0.00 |
LAUNDRY_FLR_1 | 45085.13 | 45085.13 | 577.72 | 3.398 | 3.398 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:30:00 | 24.00 | 24.00 | 0.00858 | 34.12 | 0.01447 | 0.000 | 0.00 |
CAFE_FLR_1 | 19324.80 | 19324.80 | 102.32 | 1.458 | 1.458 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 24.00 | 23.99 | 0.01027 | 34.40 | 0.01447 | 0.676 | 0.00 |
LOBBY_FLR_1 | 64234.08 | 64234.08 | 49.10 | 4.843 | 4.843 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:20:00 | 24.00 | 23.99 | 0.01008 | 34.40 | 0.01447 | 1.894 | 0.00 |
ROOM_1_FLR_3 | 10624.13 | 10624.13 | 272.26 | 1.079 | 1.079 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:10:00 | 21.11 | 21.11 | 0.00877 | 32.91 | 0.01447 | 0.062 | 0.00 |
ROOM_2_FLR_3 | 10504.22 | 10504.22 | 269.22 | 1.067 | 1.067 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:20:00 | 21.11 | 21.11 | 0.00878 | 32.75 | 0.01447 | 0.062 | 0.00 |
ROOM_3_MULT19_FLR_3 | 65801.41 | 65801.41 | 2683.16 | 6.682 | 6.682 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:20:00 | 21.11 | 21.11 | 0.00868 | 34.40 | 0.01447 | 0.837 | 0.00 |
ROOM_4_MULT19_FLR_3 | 69162.54 | 69162.54 | 2819.45 | 7.024 | 7.024 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 | 21.11 | 21.11 | 0.00887 | 34.02 | 0.01447 | 0.837 | 0.00 |
ROOM_5_FLR_3 | 9572.01 | 9572.01 | 245.30 | 0.972 | 0.972 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:40:00 | 21.11 | 21.11 | 0.00880 | 31.74 | 0.01447 | 0.062 | 0.00 |
ROOM_6_FLR_3 | 9484.40 | 9484.40 | 243.08 | 0.963 | 0.963 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:20:00 | 21.11 | 21.11 | 0.00881 | 31.26 | 0.01447 | 0.062 | 0.00 |
CORRIDOR_FLR_3 | 15430.53 | 15430.53 | 39.63 | 1.163 | 1.163 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | 24.00 | 24.00 | 0.00992 | 34.30 | 0.01447 | 0.475 | 0.00 |
ROOM_1_FLR_6 | 2850.61 | 2850.61 | 73.05 | 0.290 | 0.290 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 21.11 | 21.11 | 0.00875 | 33.07 | 0.01447 | 0.015 | 0.00 |
ROOM_2_FLR_6 | 2815.14 | 2815.14 | 72.15 | 0.286 | 0.286 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:10:00 | 21.11 | 21.11 | 0.00876 | 32.91 | 0.01447 | 0.015 | 0.00 |
ROOM_3_MULT9_FLR_6 | 13060.73 | 13060.73 | 532.43 | 1.326 | 1.326 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | 21.11 | 21.11 | 0.00882 | 34.40 | 0.01447 | 0.099 | 0.00 |
BANQUET_FLR_6 | 30827.16 | 30827.16 | 92.95 | 2.326 | 2.326 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 24.00 | 23.98 | 0.01037 | 34.40 | 0.01447 | 1.188 | 0.00 |
DINING_FLR_6 | 32340.89 | 32340.89 | 97.51 | 2.440 | 2.440 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 24.00 | 23.98 | 0.01029 | 34.40 | 0.01447 | 1.188 | 0.00 |
KITCHEN_FLR_6 | 31219.15 | 31219.15 | 302.21 | 2.359 | 2.359 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 12:30:00 | 24.00 | 23.97 | 0.01010 | 33.55 | 0.01447 | 0.367 | 0.00 |
CORRIDOR_FLR_6 | 9526.60 | 9526.60 | 23.12 | 0.718 | 0.718 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:50:00 | 24.00 | 24.00 | 0.00918 | 34.40 | 0.01447 | 0.126 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BASEMENT | 1213.38 | 1213.38 | 0.61 | 0.054 | 0.854 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | 21.00 | 21.00 | 0.00792 | -6.30 | 0.00230 | 0.854 | 0.00 |
RETAIL_1_FLR_1 | 3226.23 | 3226.23 | 48.10 | 0.143 | 0.143 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 21.00 | 21.00 | 0.00732 | -6.30 | 0.00230 | 0.079 | 0.00 |
RETAIL_2_FLR_1 | 1072.92 | 1072.92 | 13.81 | 0.048 | 0.092 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 21.00 | 21.00 | 0.00723 | -6.30 | 0.00230 | 0.092 | 0.00 |
MECH_FLR_1 | 2016.34 | 2016.34 | 12.28 | 0.090 | 0.090 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 21.00 | 21.00 | 0.00706 | -6.30 | 0.00230 | 0.000 | 0.00 |
STORAGE_FLR_1 | 1206.20 | 1206.20 | 12.73 | 0.054 | 0.058 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 21.00 | 21.00 | 0.00709 | -6.30 | 0.00230 | 0.058 | 0.00 |
LAUNDRY_FLR_1 | 2651.80 | 2651.80 | 33.98 | 0.118 | 0.118 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 21.00 | 21.00 | 0.00703 | -6.30 | 0.00230 | 0.000 | 0.00 |
CAFE_FLR_1 | 8095.70 | 8095.70 | 42.87 | 0.360 | 0.676 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 21.00 | 21.00 | 0.00740 | -6.30 | 0.00230 | 0.676 | 0.00 |
LOBBY_FLR_1 | 19168.01 | 19168.01 | 14.65 | 0.852 | 1.894 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 21.00 | 21.00 | 0.00729 | -6.30 | 0.00230 | 1.894 | 0.00 |
ROOM_1_FLR_3 | 7185.71 | 7185.71 | 184.15 | 0.321 | 0.321 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 21.11 | 21.11 | 0.00730 | -6.30 | 0.00230 | 0.062 | 0.00 |
ROOM_2_FLR_3 | 7198.10 | 7198.10 | 184.48 | 0.322 | 0.322 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 21.11 | 21.11 | 0.00730 | -6.30 | 0.00230 | 0.062 | 0.00 |
ROOM_3_MULT19_FLR_3 | 40941.37 | 40941.37 | 1669.45 | 1.831 | 1.831 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 21.11 | 21.11 | 0.00735 | -6.30 | 0.00230 | 0.837 | 0.00 |
ROOM_4_MULT19_FLR_3 | 41191.01 | 41191.01 | 1679.17 | 1.842 | 1.842 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 21.11 | 21.11 | 0.00735 | -6.30 | 0.00230 | 0.837 | 0.00 |
ROOM_5_FLR_3 | 7160.14 | 7160.14 | 183.49 | 0.320 | 0.320 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 21.11 | 21.11 | 0.00730 | -6.30 | 0.00230 | 0.062 | 0.00 |
ROOM_6_FLR_3 | 7172.53 | 7172.53 | 183.83 | 0.321 | 0.321 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 21.11 | 21.11 | 0.00730 | -6.30 | 0.00230 | 0.062 | 0.00 |
CORRIDOR_FLR_3 | 11023.74 | 11023.74 | 28.31 | 0.490 | 0.490 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 21.00 | 21.00 | 0.00743 | -6.30 | 0.00230 | 0.475 | 0.00 |
ROOM_1_FLR_6 | 2207.15 | 2207.15 | 56.56 | 0.099 | 0.099 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 21.11 | 21.11 | 0.00742 | -6.30 | 0.00230 | 0.015 | 0.00 |
ROOM_2_FLR_6 | 2212.09 | 2212.09 | 56.69 | 0.099 | 0.099 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 21.11 | 21.11 | 0.00742 | -6.30 | 0.00230 | 0.015 | 0.00 |
ROOM_3_MULT9_FLR_6 | 10571.60 | 10571.60 | 430.96 | 0.473 | 0.473 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 21.11 | 21.11 | 0.00744 | -6.30 | 0.00230 | 0.099 | 0.00 |
BANQUET_FLR_6 | 7303.68 | 7303.68 | 22.02 | 0.325 | 1.188 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 21.00 | 21.00 | 0.00756 | -6.30 | 0.00230 | 1.188 | 0.00 |
DINING_FLR_6 | 7438.79 | 7438.79 | 22.43 | 0.331 | 1.188 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 11:50:00 | 21.00 | 21.00 | 0.00756 | -6.30 | 0.00230 | 1.188 | 0.00 |
KITCHEN_FLR_6 | 2312.24 | 2312.24 | 22.38 | 0.103 | 0.367 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 23:30:00 | 21.00 | 21.00 | 0.00633 | -6.30 | 0.00230 | 0.367 | 0.00 |
CORRIDOR_FLR_6 | 7650.00 | 7650.00 | 18.56 | 0.340 | 0.340 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 11:50:00 | 21.00 | 21.00 | 0.00762 | -6.30 | 0.00230 | 0.126 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
VAV WITH REHEAT | 22.08 | 22.08 | 7.50 | 7.50 | 22.0819 | 22.0819 | 22.0819 | 1.0000 | 0.3000 |
FLR_3_DOAS | 19.10 | 2.05 | 5.63 | 2.05 | 2.0513 | 2.0513 | 2.0513 | 1.0000 | 0.3000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
BASEMENT VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | BASEMENT VAV BOX | 13901.197 | 13901.197 | 2.492750 | 0.00012161 | 291.327 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | 13901.20 | 13901.20 | 2.492750 | 16.70 | 12.85 | 0.00800000 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 0.0000 | 21.00 | 0.00792332 | 49.3905 | 1213.38 | 0.00 | 13979.19 | 13979.19 |
RETAIL_1_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | RETAIL_1_FLR_1 VAV BOX | 4933.798 | 4933.798 | 0.335940 | 0.00004316 | 114.161 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 4933.80 | 4933.80 | 0.335940 | 16.70 | 12.85 | 0.00800000 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 0.0000 | 21.00 | 0.00732362 | 45.6990 | 3226.23 | 0.00 | 4960.21 | 4960.21 |
RETAIL_2_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | RETAIL_2_FLR_1 VAV BOX | 2338.124 | 2338.124 | 0.248911 | 0.00002045 | 51.003 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 2338.12 | 2338.12 | 0.248911 | 16.70 | 12.85 | 0.00800000 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 0.0000 | 21.00 | 0.00722958 | 45.1168 | 1072.92 | 0.00 | 2351.08 | 2351.08 |
MECH_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | MECH_FLR_1 VAV BOX | 3349.556 | 3349.556 | 0.262374 | 0.00002930 | 75.823 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 3349.56 | 3349.56 | 0.262374 | 16.70 | 12.85 | 0.00800000 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 0.0000 | 21.00 | 0.00706367 | 44.0932 | 2016.34 | 0.00 | 3367.62 | 3367.62 |
STORAGE_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | STORAGE_FLR_1 VAV BOX | 1871.318 | 1871.318 | 0.130886 | 0.00001637 | 43.105 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 1871.32 | 1871.32 | 0.130886 | 16.70 | 12.85 | 0.00800000 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 0.0000 | 21.00 | 0.00709166 | 44.2660 | 1206.20 | 0.00 | 1881.35 | 1881.35 |
LAUNDRY_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | 19827.684 | 19827.684 | 3.380941 | 0.00017346 | 416.758 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 19827.68 | 19827.68 | 3.380941 | 16.70 | 12.85 | 0.00800000 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 0.0000 | 21.00 | 0.00703397 | 43.9119 | 2651.80 | 0.00 | 19938.81 | 19938.81 |
CAFE_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | CAFE_FLR_1 VAV BOX | 15469.866 | 15469.866 | 1.450504 | 0.00013534 | 342.111 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 15469.87 | 15469.87 | 1.450504 | 16.70 | 12.85 | 0.00800000 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 0.0000 | 21.00 | 0.00739563 | 46.1424 | 8095.70 | 0.00 | 15554.06 | 15554.06 |
LOBBY_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | 43663.118 | 43663.118 | 4.818571 | 0.00038198 | 949.068 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 43663.12 | 43663.12 | 4.818571 | 16.70 | 12.85 | 0.00800000 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 0.0000 | 21.00 | 0.00728627 | 45.4666 | 19168.01 | 0.00 | 43905.24 | 43905.24 |
ROOM_1_FLR_3 FAN COIL COOLING COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_1_FLR_3 FAN COIL | 13319.333 | -999.000 | 1.078996 | 0.00047573 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:10:00 | unknown | 7/21 17:10:00 | 13319.33 | 12575.28 | 1.078996 | 22.54 | 15.73 | 0.00877288 | 12.80 | 11.77 | 0.00850000 | 32.91 | 0.01447054 | 23.14 | 0.0000 | 21.11 | 0.00877288 | 54.2462 | 10624.13 | 0.00 | 13763.11 | 12742.20 |
ROOM_1_FLR_3 FAN COIL HEATING COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_1_FLR_3 FAN COIL | 7185.546 | 7185.546 | 0.321305 | 0.00006286 | 205.365 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 7185.55 | 7185.55 | 0.321305 | 21.11 | 13.90 | 0.00730207 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 0.0000 | 21.11 | 0.00730207 | 45.2571 | 7185.71 | 0.00 | 7746.10 | 7746.10 |
ROOM_2_FLR_3 FAN COIL COOLING COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_2_FLR_3 FAN COIL | 13180.004 | -999.000 | 1.066818 | 0.00047075 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:20:00 | unknown | 7/21 17:20:00 | 13180.00 | 12434.84 | 1.066818 | 22.54 | 15.74 | 0.00877637 | 12.80 | 11.77 | 0.00850000 | 32.75 | 0.01447025 | 23.10 | 0.0000 | 21.11 | 0.00877637 | 54.2675 | 10504.22 | 0.00 | 13618.96 | 12599.78 |
ROOM_2_FLR_3 FAN COIL HEATING COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_2_FLR_3 FAN COIL | 7197.929 | 7197.929 | 0.321859 | 0.00006297 | 205.719 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 7197.93 | 7197.93 | 0.321859 | 21.11 | 13.90 | 0.00730317 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 0.0000 | 21.11 | 0.00730317 | 45.2638 | 7198.10 | 0.00 | 7759.44 | 7759.44 |
ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_3_MULT19_FLR_3 FAN COIL | 80570.617 | -999.000 | 6.682092 | 0.00287774 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:20:00 | unknown | 7/21 14:20:00 | 80570.62 | 77619.65 | 6.682092 | 22.54 | 15.65 | 0.00867536 | 12.80 | 11.77 | 0.00850000 | 34.40 | 0.01447326 | 23.54 | 0.0000 | 21.11 | 0.00867536 | 53.6484 | 65801.41 | 0.00 | 83286.36 | 78669.78 |
ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_3_MULT19_FLR_3 FAN COIL | 40940.917 | 40940.917 | 1.830765 | 0.00035817 | 1170.083 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 40940.92 | 40940.92 | 1.830765 | 21.11 | 13.94 | 0.00734503 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 0.0000 | 21.11 | 0.00734503 | 45.5181 | 40941.37 | 0.00 | 44135.29 | 44135.29 |
ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_4_MULT19_FLR_3 FAN COIL | 88705.766 | -999.000 | 7.023944 | 0.00316831 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 | unknown | 7/21 15:40:00 | 88705.77 | 82128.48 | 7.023944 | 22.54 | 15.82 | 0.00886935 | 12.80 | 11.77 | 0.00850000 | 34.02 | 0.01447257 | 23.44 | 0.0000 | 21.11 | 0.00886935 | 54.8333 | 69162.54 | 0.00 | 91628.01 | 83198.78 |
ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_4_MULT19_FLR_3 FAN COIL | 41190.555 | 41190.555 | 1.841928 | 0.00036035 | 1177.215 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 41190.56 | 41190.56 | 1.841928 | 21.11 | 13.94 | 0.00734839 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 0.0000 | 21.11 | 0.00734839 | 45.5387 | 41191.01 | 0.00 | 44404.41 | 44404.41 |
ROOM_5_FLR_3 FAN COIL COOLING COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_5_FLR_3 FAN COIL | 12087.380 | -999.000 | 0.972144 | 0.00043173 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:40:00 | unknown | 7/21 10:40:00 | 12087.38 | 11341.62 | 0.972144 | 22.54 | 15.76 | 0.00880325 | 12.80 | 11.77 | 0.00850000 | 31.74 | 0.01446840 | 22.83 | 0.0000 | 21.11 | 0.00880325 | 54.4315 | 9572.01 | 0.00 | 12488.67 | 11491.29 |
ROOM_5_FLR_3 FAN COIL HEATING COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_5_FLR_3 FAN COIL | 7159.972 | 7159.972 | 0.320162 | 0.00006264 | 204.634 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 7159.97 | 7159.97 | 0.320162 | 21.11 | 13.90 | 0.00729988 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 0.0000 | 21.11 | 0.00729988 | 45.2437 | 7160.14 | 0.00 | 7718.53 | 7718.53 |
ROOM_6_FLR_3 FAN COIL COOLING COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_6_FLR_3 FAN COIL | 11984.444 | -999.000 | 0.963247 | 0.00042805 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:20:00 | unknown | 7/21 10:20:00 | 11984.44 | 11238.85 | 0.963247 | 22.54 | 15.76 | 0.00880596 | 12.80 | 11.77 | 0.00850000 | 31.26 | 0.01446754 | 22.70 | 0.0000 | 21.11 | 0.00880596 | 54.4480 | 9484.40 | 0.00 | 12382.19 | 11387.08 |
ROOM_6_FLR_3 FAN COIL HEATING COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_6_FLR_3 FAN COIL | 7172.364 | 7172.364 | 0.320716 | 0.00006275 | 204.988 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 7172.36 | 7172.36 | 0.320716 | 21.11 | 13.90 | 0.00730099 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 0.0000 | 21.11 | 0.00730099 | 45.2505 | 7172.53 | 0.00 | 7731.88 | 7731.88 |
CORRIDOR_FLR_3 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORRIDOR_FLR_3 VAV BOX | 16907.373 | 16907.373 | 1.157035 | 0.00014791 | 390.877 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 16907.37 | 16907.37 | 1.157035 | 16.70 | 12.85 | 0.00800000 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 0.0000 | 21.00 | 0.00743224 | 46.3660 | 11023.74 | 0.00 | 16997.90 | 16997.90 |
ROOM_1_FLR_6 FAN COIL COOLING COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_1_FLR_6 FAN COIL | 3558.184 | -999.000 | 0.289510 | 0.00012709 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | unknown | 7/21 17:00:00 | 3558.18 | 3372.02 | 0.289510 | 22.54 | 15.72 | 0.00875462 | 12.80 | 11.77 | 0.00850000 | 33.07 | 0.01447082 | 23.19 | 0.0000 | 21.11 | 0.00875462 | 54.1348 | 2850.61 | 0.00 | 3676.99 | 3416.94 |
ROOM_1_FLR_6 FAN COIL HEATING COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_1_FLR_6 FAN COIL | 2207.095 | 2207.095 | 0.098691 | 0.00001931 | 63.075 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 2207.10 | 2207.10 | 0.098691 | 21.11 | 14.01 | 0.00741860 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 0.0000 | 21.11 | 0.00741860 | 45.9708 | 2207.15 | 0.00 | 2379.27 | 2379.27 |
ROOM_2_FLR_6 FAN COIL COOLING COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_2_FLR_6 FAN COIL | 3516.814 | -999.000 | 0.285908 | 0.00012561 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:10:00 | unknown | 7/21 17:10:00 | 3516.81 | 3330.46 | 0.285908 | 22.54 | 15.72 | 0.00875807 | 12.80 | 11.77 | 0.00850000 | 32.91 | 0.01447054 | 23.14 | 0.0000 | 21.11 | 0.00875807 | 54.1559 | 2815.14 | 0.00 | 3634.19 | 3374.79 |
ROOM_2_FLR_6 FAN COIL HEATING COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_2_FLR_6 FAN COIL | 2212.042 | 2212.042 | 0.098913 | 0.00001935 | 63.216 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 2212.04 | 2212.04 | 0.098913 | 21.11 | 14.01 | 0.00741981 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 0.0000 | 21.11 | 0.00741981 | 45.9782 | 2212.09 | 0.00 | 2384.61 | 2384.61 |
ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_3_MULT9_FLR_6 FAN COIL | 16548.409 | -999.000 | 1.326459 | 0.00059106 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | unknown | 7/21 14:30:00 | 16548.41 | 15482.69 | 1.326459 | 22.54 | 15.77 | 0.00881745 | 12.80 | 11.77 | 0.00850000 | 34.40 | 0.01447326 | 23.54 | 0.0000 | 21.11 | 0.00881745 | 54.5180 | 13060.73 | 0.00 | 17096.89 | 15686.45 |
ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_3_MULT9_FLR_6 FAN COIL | 10571.409 | 10571.409 | 0.472712 | 0.00009248 | 302.110 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 10571.41 | 10571.41 | 0.472712 | 21.11 | 14.02 | 0.00743885 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 0.0000 | 21.11 | 0.00743885 | 46.0940 | 10571.60 | 0.00 | 11396.14 | 11396.14 |
BANQUET_FLR_6 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | 19074.637 | 19074.637 | 2.314415 | 0.00016687 | 411.002 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 19074.64 | 19074.64 | 2.314415 | 16.70 | 12.85 | 0.00800000 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 0.0000 | 21.00 | 0.00755682 | 47.1347 | 7303.68 | 0.00 | 19180.68 | 19180.68 |
DINING_FLR_6 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | 19787.807 | 19787.807 | 2.428023 | 0.00017311 | 425.953 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 11:50:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 11:50:00 | 19787.81 | 19787.81 | 2.428023 | 16.70 | 12.85 | 0.00800000 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 0.0000 | 21.00 | 0.00756427 | 47.1805 | 7438.79 | 0.00 | 19897.84 | 19897.84 |
KITCHEN_FLR_6 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | 14213.111 | 14213.111 | 2.347212 | 0.00012434 | 299.332 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 23:30:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 23:30:00 | 14213.11 | 14213.11 | 2.347212 | 16.70 | 12.85 | 0.00800000 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 0.0000 | 21.00 | 0.00632950 | 39.5654 | 2312.24 | 0.00 | 14292.71 | 14292.71 |
CORRIDOR_FLR_6 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORRIDOR_FLR_6 VAV BOX | 11283.653 | 11283.653 | 0.714338 | 0.00009871 | 264.491 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 11:50:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 11:50:00 | 11283.65 | 11283.65 | 0.714338 | 16.70 | 12.85 | 0.00800000 | 40.00 | 20.76 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 0.0000 | 21.00 | 0.00762451 | 47.5513 | 7650.00 | 0.00 | 11343.82 | 11343.82 |
VAV WITH REHEAT COOLING COIL | Coil:Cooling:Water | AirLoopHVAC | VAV WITH REHEAT | 1006896.452 | -999.000 | 22.081900 | 0.03596401 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | 1006896.45 | 612915.86 | 22.081900 | 34.40 | 23.54 | 0.01447326 | 10.93 | 10.93 | 0.00850000 | 34.40 | 0.01447326 | 23.54 | 99.9903 | 23.99 | 0.00977089 | 50.6346 | 292778.63 | 0.00 | 1022938.78 | 614792.33 |
VAV WITH REHEAT HEATING COIL | Coil:Heating:Water | AirLoopHVAC | VAV WITH REHEAT | 177751.763 | 177751.763 | 6.624570 | 0.00155505 | 3000.095 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | 177751.76 | 177751.76 | 6.624570 | -6.30 | -6.30 | 0.00229779 | 16.70 | 12.85 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 333.3009 | 21.01 | 0.00739373 | 46.1013 | 73464.09 | 0.00 | 159853.92 | 159853.92 |
FLR_3_DOAS COOLING COIL | Coil:Cooling:Water | AirLoopHVAC | FLR_3_DOAS | 91161.109 | -999.000 | 2.051317 | 0.00325606 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:30:00 | 91161.11 | 55491.40 | 2.051317 | 34.40 | 23.54 | 0.01447326 | 11.91 | 11.41 | 0.00850000 | 34.40 | 0.01447326 | 23.54 | 99.9965 | 21.11 | 0.00877681 | 54.2682 | 187594.30 | 0.00 | 92644.03 | 56011.80 |
FLR_3_DOAS HEATING COIL | Coil:Heating:Water | AirLoopHVAC | FLR_3_DOAS | 16512.404 | 16512.404 | 0.615395 | 0.00014446 | 278.696 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | 16512.40 | 16512.40 | 0.615395 | -6.30 | -6.30 | 0.00229779 | 16.70 | 12.85 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 333.3216 | 21.11 | 0.00734732 | 45.5322 | 125839.70 | 0.00 | 14849.77 | 14849.77 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
BASEMENT VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | BASEMENT VAV BOX | BASEMENT | N/A | N/A | N/A | Yes | Yes | Yes | No | 13901.197 | 13901.197 | 2.492750 | 0.00012161 | 291.327 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 4.43258374 | 54.44 | 82.22 | 27.78 | 516921.25 | 2.6892 | 2.743351 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 24:00:00 | Sensible | 13901.20 | 13901.20 | 1.0000 | 2.89402411 | 2.492750 | 16.70 | 12.85 | 0.00800000 | 37036.7 | 40.00 | 20.76 | 0.00800000 | 60796.0 | 0.12160133 | 60.00 | 32.22 | 27.78 | 0.000 | 13901.20 | -6.30 | 0.00229779 | -6.30 | 0.00000000 | 0.0000 | 21.00 | 0.00792332 | 21.00 | 0.00792332 | 49.3905 | 1213.38 | 0.00 | 13979.19 | 13979.19 | 2.89402411 | 16.60 | 13.15 | 0.00800000 | 36934.7 | 21.34 | 14.98 | 0.00800000 | 41765.1 | |
RETAIL_1_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | RETAIL_1_FLR_1 VAV BOX | RETAIL_1_FLR_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 4933.798 | 4933.798 | 0.335940 | 0.00004316 | 114.161 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 4.43258374 | 54.44 | 82.22 | 27.78 | 516921.25 | 0.9545 | 0.973667 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | Sensible | 4933.80 | 4933.80 | 1.0000 | 0.39001890 | 0.335940 | 16.70 | 12.85 | 0.00800000 | 37036.7 | 40.00 | 20.76 | 0.00800000 | 60796.0 | 0.04315861 | 60.00 | 32.22 | 27.78 | 0.000 | 4933.80 | -6.30 | 0.00229779 | -6.30 | 0.00000000 | 0.0000 | 21.00 | 0.00732362 | 21.00 | 0.00732362 | 45.6990 | 3226.23 | 0.00 | 4960.21 | 4960.21 | 0.39001890 | 16.60 | 13.15 | 0.00800000 | 36934.7 | 29.07 | 17.73 | 0.00800000 | 49652.6 | |
RETAIL_2_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | RETAIL_2_FLR_1 VAV BOX | RETAIL_2_FLR_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 2338.124 | 2338.124 | 0.248911 | 0.00002045 | 51.003 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 4.43258374 | 54.44 | 82.22 | 27.78 | 516921.25 | 0.4523 | 0.461420 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | Sensible | 2338.12 | 2338.12 | 1.0000 | 0.28897989 | 0.248911 | 16.70 | 12.85 | 0.00800000 | 37036.7 | 40.00 | 20.76 | 0.00800000 | 60796.0 | 0.02045285 | 60.00 | 32.22 | 27.78 | 0.000 | 2338.12 | -6.30 | 0.00229779 | -6.30 | 0.00000000 | 0.0000 | 21.00 | 0.00722958 | 21.00 | 0.00722958 | 45.1168 | 1072.92 | 0.00 | 2351.08 | 2351.08 | 0.28897989 | 16.60 | 13.15 | 0.00800000 | 36934.7 | 24.58 | 16.16 | 0.00800000 | 45070.5 | |
MECH_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | MECH_FLR_1 VAV BOX | MECH_FLR_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 3349.556 | 3349.556 | 0.262374 | 0.00002930 | 75.823 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 4.43258374 | 54.44 | 82.22 | 27.78 | 516921.25 | 0.6480 | 0.661023 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | Sensible | 3349.56 | 3349.56 | 1.0000 | 0.30461002 | 0.262374 | 16.70 | 12.85 | 0.00800000 | 37036.7 | 40.00 | 20.76 | 0.00800000 | 60796.0 | 0.02930039 | 60.00 | 32.22 | 27.78 | 0.000 | 3349.56 | -6.30 | 0.00229779 | -6.30 | 0.00000000 | 0.0000 | 21.00 | 0.00706367 | 21.00 | 0.00706367 | 44.0932 | 2016.34 | 0.00 | 3367.62 | 3367.62 | 0.30461002 | 16.60 | 13.15 | 0.00800000 | 36934.7 | 27.44 | 17.17 | 0.00800000 | 47990.3 | |
STORAGE_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | STORAGE_FLR_1 VAV BOX | STORAGE_FLR_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 1871.318 | 1871.318 | 0.130886 | 0.00001637 | 43.105 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 4.43258374 | 54.44 | 82.22 | 27.78 | 516921.25 | 0.3620 | 0.369298 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | Sensible | 1871.32 | 1871.32 | 1.0000 | 0.15195571 | 0.130886 | 16.70 | 12.85 | 0.00800000 | 37036.7 | 40.00 | 20.76 | 0.00800000 | 60796.0 | 0.01636944 | 60.00 | 32.22 | 27.78 | 0.000 | 1871.32 | -6.30 | 0.00229779 | -6.30 | 0.00000000 | 0.0000 | 21.00 | 0.00709166 | 21.00 | 0.00709166 | 44.2660 | 1206.20 | 0.00 | 1881.35 | 1881.35 | 0.15195571 | 16.60 | 13.15 | 0.00800000 | 36934.7 | 28.74 | 17.61 | 0.00800000 | 49315.6 | |
LAUNDRY_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | Unknown | LAUNDRY_FLR_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 19827.684 | 19827.684 | 3.380941 | 0.00017346 | 416.758 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 4.43258374 | 54.44 | 82.22 | 27.78 | 516921.25 | 3.8357 | 3.912922 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | Sensible | 19827.68 | 19827.68 | 1.0000 | 3.92519361 | 3.380941 | 16.70 | 12.85 | 0.00800000 | 37036.7 | 40.00 | 20.76 | 0.00800000 | 60796.0 | 0.17344353 | 60.00 | 32.22 | 27.78 | 0.000 | 19827.68 | -6.30 | 0.00229779 | -6.30 | 0.00000000 | 0.0000 | 21.00 | 0.00703397 | 21.00 | 0.00703397 | 43.9119 | 2651.80 | 0.00 | 19938.81 | 19938.81 | 3.92519361 | 16.60 | 13.15 | 0.00800000 | 36934.7 | 21.58 | 15.07 | 0.00800000 | 42014.4 | |
CAFE_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CAFE_FLR_1 VAV BOX | CAFE_FLR_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 15469.866 | 15469.866 | 1.450504 | 0.00013534 | 342.111 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 4.43258374 | 54.44 | 82.22 | 27.78 | 516921.25 | 2.9927 | 3.052922 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | Sensible | 15469.87 | 15469.87 | 1.0000 | 1.68400144 | 1.450504 | 16.70 | 12.85 | 0.00800000 | 37036.7 | 40.00 | 20.76 | 0.00800000 | 60796.0 | 0.13532333 | 60.00 | 32.22 | 27.78 | 0.000 | 15469.87 | -6.30 | 0.00229779 | -6.30 | 0.00000000 | 0.0000 | 21.00 | 0.00739563 | 21.00 | 0.00739563 | 46.1424 | 8095.70 | 0.00 | 15554.06 | 15554.06 | 1.68400144 | 16.60 | 13.15 | 0.00800000 | 36934.7 | 25.66 | 16.55 | 0.00800000 | 46171.1 | |
LOBBY_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | Unknown | LOBBY_FLR_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 43663.118 | 43663.118 | 4.818571 | 0.00038198 | 949.068 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 4.43258374 | 54.44 | 82.22 | 27.78 | 516921.25 | 8.4468 | 8.616759 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | Sensible | 43663.12 | 43663.12 | 1.0000 | 5.59424732 | 4.818571 | 16.70 | 12.85 | 0.00800000 | 37036.7 | 40.00 | 20.76 | 0.00800000 | 60796.0 | 0.38194504 | 60.00 | 32.22 | 27.78 | 0.000 | 43663.12 | -6.30 | 0.00229779 | -6.30 | 0.00000000 | 0.0000 | 21.00 | 0.00728627 | 21.00 | 0.00728627 | 45.4666 | 19168.01 | 0.00 | 43905.24 | 43905.24 | 5.59424732 | 16.60 | 13.15 | 0.00800000 | 36934.7 | 24.30 | 16.06 | 0.00800000 | 44783.0 | |
ROOM_1_FLR_3 FAN COIL COOLING COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_1_FLR_3 FAN COIL | ROOM_1_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 13319.333 | -999.000 | 1.078996 | 0.00047573 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.1483 | 1004.8586 | 1.1610 | ROOM_1_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 1.078996 | 1.25268852 | 4197.9300 | 999.8980 | 47.91123978 | 13.37 | 6.70 | 6.67 | 1341523.97 | 0.9929 | 0.992832 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:10:00 | unknown | unknown | unknown | 7/21 17:10:00 | Sensible | 13319.33 | 12575.28 | 1.0000 | 1.25268852 | 1.078996 | 22.54 | 15.73 | 0.00877288 | 44954.8 | 12.80 | 11.77 | 0.00850000 | 34322.2 | 0.47567830 | 6.70 | 13.37 | 6.67 | 0.000 | 13319.33 | 32.91 | 0.01447054 | 23.14 | 0.00000000 | 0.0000 | 21.11 | 0.00877288 | 21.11 | 0.00877288 | 54.2462 | 10624.13 | 0.00 | 13763.11 | 12742.20 | 1.25268852 | 22.54 | 16.10 | 0.00877288 | 44954.8 | 12.58 | 11.96 | 0.00845003 | 33967.9 | |
ROOM_1_FLR_3 FAN COIL HEATING COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_1_FLR_3 FAN COIL | ROOM_1_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 7185.546 | 7185.546 | 0.321305 | 0.00006286 | 205.365 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | ROOM_1_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 1.078996 | 1.25268852 | 4197.9300 | 999.8980 | 4.43258374 | 54.44 | 82.22 | 27.78 | 516921.25 | 1.3901 | 1.418042 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | Sensible | 7185.55 | 7185.55 | 1.0000 | 0.37302763 | 0.321305 | 21.11 | 13.90 | 0.00730207 | 39760.3 | 40.00 | 20.76 | 0.00800000 | 60796.0 | 0.06285588 | 60.00 | 32.22 | 27.78 | 0.000 | 7185.55 | -6.30 | 0.00229779 | -6.30 | 0.00000000 | 0.0000 | 21.11 | 0.00730207 | 21.11 | 0.00730207 | 45.2571 | 7185.71 | 0.00 | 7746.10 | 7746.10 | 0.37302763 | 16.60 | 12.47 | 0.00730207 | 35167.7 | 36.99 | 19.75 | 0.00730207 | 55933.2 | |
ROOM_2_FLR_3 FAN COIL COOLING COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_2_FLR_3 FAN COIL | ROOM_2_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 13180.004 | -999.000 | 1.066818 | 0.00047075 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.1548 | 1004.8586 | 1.1610 | ROOM_2_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 1.066818 | 1.23855052 | 4197.9300 | 999.8980 | 47.91123978 | 13.37 | 6.70 | 6.67 | 1341523.97 | 0.9825 | 0.982447 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:20:00 | unknown | unknown | unknown | 7/21 17:20:00 | Sensible | 13180.00 | 12434.84 | 1.0000 | 1.23855052 | 1.066818 | 22.54 | 15.74 | 0.00877637 | 44963.7 | 12.80 | 11.77 | 0.00850000 | 34322.2 | 0.47070240 | 6.70 | 13.37 | 6.67 | 0.000 | 13180.00 | 32.75 | 0.01447025 | 23.10 | 0.00000000 | 0.0000 | 21.11 | 0.00877637 | 21.11 | 0.00877637 | 54.2675 | 10504.22 | 0.00 | 13618.96 | 12599.78 | 1.23855052 | 22.54 | 16.11 | 0.00877637 | 44963.7 | 12.58 | 11.96 | 0.00845039 | 33967.8 | |
ROOM_2_FLR_3 FAN COIL HEATING COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_2_FLR_3 FAN COIL | ROOM_2_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 7197.929 | 7197.929 | 0.321859 | 0.00006297 | 205.719 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | ROOM_2_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 1.066818 | 1.23855052 | 4197.9300 | 999.8980 | 4.43258374 | 54.44 | 82.22 | 27.78 | 516921.25 | 1.3925 | 1.420485 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | Sensible | 7197.93 | 7197.93 | 1.0000 | 0.37367047 | 0.321859 | 21.11 | 13.90 | 0.00730317 | 39763.1 | 40.00 | 20.76 | 0.00800000 | 60796.0 | 0.06296420 | 60.00 | 32.22 | 27.78 | 0.000 | 7197.93 | -6.30 | 0.00229779 | -6.30 | 0.00000000 | 0.0000 | 21.11 | 0.00730317 | 21.11 | 0.00730317 | 45.2638 | 7198.10 | 0.00 | 7759.44 | 7759.44 | 0.37367047 | 16.60 | 12.47 | 0.00730317 | 35170.5 | 36.99 | 19.75 | 0.00730317 | 55936.0 | |
ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_3_MULT19_FLR_3 FAN COIL | ROOM_3_MULT19_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 80570.617 | -999.000 | 6.682092 | 0.00287774 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9671 | 1004.8586 | 1.1610 | ROOM_3_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 6.682092 | 7.75775194 | 4197.9300 | 999.8980 | 47.91123978 | 13.37 | 6.70 | 6.67 | 1341523.97 | 6.0059 | 6.005790 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:20:00 | unknown | unknown | unknown | 7/21 14:20:00 | Sensible | 80570.62 | 77619.65 | 1.0000 | 7.75775194 | 6.682092 | 22.54 | 15.65 | 0.00867536 | 44708.0 | 12.80 | 11.77 | 0.00850000 | 34322.2 | 2.87744844 | 6.70 | 13.37 | 6.67 | 0.000 | 80570.62 | 34.40 | 0.01447326 | 23.54 | 0.00000000 | 0.0000 | 21.11 | 0.00867536 | 21.11 | 0.00867536 | 53.6484 | 65801.41 | 0.00 | 83286.36 | 78669.78 | 7.75775194 | 22.54 | 16.02 | 0.00867536 | 44708.0 | 12.61 | 11.96 | 0.00843962 | 33972.1 | |
ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_3_MULT19_FLR_3 FAN COIL | ROOM_3_MULT19_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 40940.917 | 40940.917 | 1.830765 | 0.00035817 | 1170.083 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | ROOM_3_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 6.682092 | 7.75775194 | 4197.9300 | 999.8980 | 4.43258374 | 54.44 | 82.22 | 27.78 | 516921.25 | 7.9201 | 8.079542 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | Sensible | 40940.92 | 40940.92 | 1.0000 | 2.12547516 | 1.830765 | 21.11 | 13.94 | 0.00734503 | 39870.2 | 40.00 | 20.76 | 0.00800000 | 60796.0 | 0.35813246 | 60.00 | 32.22 | 27.78 | 0.000 | 40940.92 | -6.30 | 0.00229779 | -6.30 | 0.00000000 | 0.0000 | 21.11 | 0.00734503 | 21.11 | 0.00734503 | 45.5181 | 40941.37 | 0.00 | 44135.29 | 44135.29 | 2.12547516 | 16.60 | 12.51 | 0.00734503 | 35276.5 | 36.99 | 19.78 | 0.00734503 | 56041.4 | |
ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_4_MULT19_FLR_3 FAN COIL | ROOM_4_MULT19_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 88705.766 | -999.000 | 7.023944 | 0.00316831 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.3277 | 1004.8586 | 1.1610 | ROOM_4_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 7.023944 | 8.15463402 | 4197.9300 | 999.8980 | 47.91123978 | 13.37 | 6.70 | 6.67 | 1341523.97 | 6.6123 | 6.612190 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 | unknown | unknown | unknown | 7/21 15:40:00 | Sensible | 88705.77 | 82128.48 | 1.0000 | 8.15463402 | 7.023944 | 22.54 | 15.82 | 0.00886935 | 45200.2 | 12.80 | 11.77 | 0.00850000 | 34322.2 | 3.16798207 | 6.70 | 13.37 | 6.67 | 0.000 | 88705.77 | 34.02 | 0.01447257 | 23.44 | 0.00000000 | 0.0000 | 21.11 | 0.00886935 | 21.11 | 0.00886935 | 54.8333 | 69162.54 | 0.00 | 91628.01 | 83198.78 | 8.15463402 | 22.54 | 16.19 | 0.00886935 | 45200.2 | 12.55 | 11.96 | 0.00845985 | 33963.8 | |
ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_4_MULT19_FLR_3 FAN COIL | ROOM_4_MULT19_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 41190.555 | 41190.555 | 1.841928 | 0.00036035 | 1177.215 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | ROOM_4_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 7.023944 | 8.15463402 | 4197.9300 | 999.8980 | 4.43258374 | 54.44 | 82.22 | 27.78 | 516921.25 | 7.9684 | 8.128807 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | Sensible | 41190.56 | 41190.56 | 1.0000 | 2.13843530 | 1.841928 | 21.11 | 13.94 | 0.00734839 | 39878.8 | 40.00 | 20.76 | 0.00800000 | 60796.0 | 0.36031619 | 60.00 | 32.22 | 27.78 | 0.000 | 41190.56 | -6.30 | 0.00229779 | -6.30 | 0.00000000 | 0.0000 | 21.11 | 0.00734839 | 21.11 | 0.00734839 | 45.5387 | 41191.01 | 0.00 | 44404.41 | 44404.41 | 2.13843530 | 16.60 | 12.51 | 0.00734839 | 35285.0 | 36.99 | 19.78 | 0.00734839 | 56049.9 | |
ROOM_5_FLR_3 FAN COIL COOLING COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_5_FLR_3 FAN COIL | ROOM_5_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 12087.380 | -999.000 | 0.972144 | 0.00043173 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.2048 | 1004.8586 | 1.1610 | ROOM_5_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.972144 | 1.12863601 | 4197.9300 | 999.8980 | 47.91123978 | 13.37 | 6.70 | 6.67 | 1341523.97 | 0.9010 | 0.901002 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:40:00 | unknown | unknown | unknown | 7/21 10:40:00 | Sensible | 12087.38 | 11341.62 | 1.0000 | 1.12863601 | 0.972144 | 22.54 | 15.76 | 0.00880325 | 45031.9 | 12.80 | 11.77 | 0.00850000 | 34322.2 | 0.43168110 | 6.70 | 13.37 | 6.67 | 0.000 | 12087.38 | 31.74 | 0.01446840 | 22.83 | 0.00000000 | 0.0000 | 21.11 | 0.00880325 | 21.11 | 0.00880325 | 54.4315 | 9572.01 | 0.00 | 12488.67 | 11491.29 | 1.12863601 | 22.54 | 16.13 | 0.00880325 | 45031.9 | 12.57 | 11.96 | 0.00845317 | 33966.6 | |
ROOM_5_FLR_3 FAN COIL HEATING COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_5_FLR_3 FAN COIL | ROOM_5_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 7159.972 | 7159.972 | 0.320162 | 0.00006264 | 204.634 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | ROOM_5_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.972144 | 1.12863601 | 4197.9300 | 999.8980 | 4.43258374 | 54.44 | 82.22 | 27.78 | 516921.25 | 1.3851 | 1.412995 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | Sensible | 7159.97 | 7159.97 | 1.0000 | 0.37170000 | 0.320162 | 21.11 | 13.90 | 0.00729988 | 39754.8 | 40.00 | 20.76 | 0.00800000 | 60796.0 | 0.06263217 | 60.00 | 32.22 | 27.78 | 0.000 | 7159.97 | -6.30 | 0.00229779 | -6.30 | 0.00000000 | 0.0000 | 21.11 | 0.00729988 | 21.11 | 0.00729988 | 45.2437 | 7160.14 | 0.00 | 7718.53 | 7718.53 | 0.37170000 | 16.60 | 12.46 | 0.00729988 | 35162.2 | 36.99 | 19.75 | 0.00729988 | 55927.7 | |
ROOM_6_FLR_3 FAN COIL COOLING COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_6_FLR_3 FAN COIL | ROOM_6_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 11984.444 | -999.000 | 0.963247 | 0.00042805 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.2098 | 1004.8586 | 1.1610 | ROOM_6_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.963247 | 1.11830708 | 4197.9300 | 999.8980 | 47.91123978 | 13.37 | 6.70 | 6.67 | 1341523.97 | 0.8933 | 0.893329 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:20:00 | unknown | unknown | unknown | 7/21 10:20:00 | Sensible | 11984.44 | 11238.85 | 1.0000 | 1.11830708 | 0.963247 | 22.54 | 15.76 | 0.00880596 | 45038.8 | 12.80 | 11.77 | 0.00850000 | 34322.2 | 0.42800490 | 6.70 | 13.37 | 6.67 | 0.000 | 11984.44 | 31.26 | 0.01446754 | 22.70 | 0.00000000 | 0.0000 | 21.11 | 0.00880596 | 21.11 | 0.00880596 | 54.4480 | 9484.40 | 0.00 | 12382.19 | 11387.08 | 1.11830708 | 22.54 | 16.13 | 0.00880596 | 45038.8 | 12.57 | 11.96 | 0.00845345 | 33966.5 | |
ROOM_6_FLR_3 FAN COIL HEATING COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_6_FLR_3 FAN COIL | ROOM_6_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 7172.364 | 7172.364 | 0.320716 | 0.00006275 | 204.988 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | ROOM_6_FLR_3 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.963247 | 1.11830708 | 4197.9300 | 999.8980 | 4.43258374 | 54.44 | 82.22 | 27.78 | 516921.25 | 1.3875 | 1.415440 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | Sensible | 7172.36 | 7172.36 | 1.0000 | 0.37234327 | 0.320716 | 21.11 | 13.90 | 0.00730099 | 39757.6 | 40.00 | 20.76 | 0.00800000 | 60796.0 | 0.06274056 | 60.00 | 32.22 | 27.78 | 0.000 | 7172.36 | -6.30 | 0.00229779 | -6.30 | 0.00000000 | 0.0000 | 21.11 | 0.00730099 | 21.11 | 0.00730099 | 45.2505 | 7172.53 | 0.00 | 7731.88 | 7731.88 | 0.37234327 | 16.60 | 12.47 | 0.00730099 | 35165.0 | 36.99 | 19.75 | 0.00730099 | 55930.5 | |
CORRIDOR_FLR_3 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORRIDOR_FLR_3 VAV BOX | CORRIDOR_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 16907.373 | 16907.373 | 1.157035 | 0.00014791 | 390.877 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 4.43258374 | 54.44 | 82.22 | 27.78 | 516921.25 | 3.2708 | 3.336609 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | Sensible | 16907.37 | 16907.37 | 1.0000 | 1.34329048 | 1.157035 | 16.70 | 12.85 | 0.00800000 | 37036.7 | 40.00 | 20.76 | 0.00800000 | 60796.0 | 0.14789798 | 60.00 | 32.22 | 27.78 | 0.000 | 16907.37 | -6.30 | 0.00229779 | -6.30 | 0.00000000 | 0.0000 | 21.00 | 0.00743224 | 21.00 | 0.00743224 | 46.3660 | 11023.74 | 0.00 | 16997.90 | 16997.90 | 1.34329048 | 16.60 | 13.15 | 0.00800000 | 36934.7 | 29.01 | 17.70 | 0.00800000 | 49588.7 | |
ROOM_1_FLR_6 FAN COIL COOLING COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_1_FLR_6 FAN COIL | ROOM_1_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 3558.184 | -999.000 | 0.289510 | 0.00012709 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.1144 | 1004.8586 | 1.1610 | ROOM_1_FLR_6 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.289510 | 0.33611444 | 4197.9300 | 999.8980 | 47.91123978 | 13.37 | 6.70 | 6.67 | 1341523.97 | 0.2652 | 0.265230 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | unknown | unknown | unknown | 7/21 17:00:00 | Sensible | 3558.18 | 3372.02 | 1.0000 | 0.33611444 | 0.289510 | 22.54 | 15.72 | 0.00875462 | 44908.4 | 12.80 | 11.77 | 0.00850000 | 34322.2 | 0.12707476 | 6.70 | 13.37 | 6.67 | 0.000 | 3558.18 | 33.07 | 0.01447082 | 23.19 | 0.00000000 | 0.0000 | 21.11 | 0.00875462 | 21.11 | 0.00875462 | 54.1348 | 2850.61 | 0.00 | 3676.99 | 3416.94 | 0.33611444 | 22.54 | 16.09 | 0.00875462 | 44908.4 | 12.58 | 11.96 | 0.00844812 | 33968.7 | |
ROOM_1_FLR_6 FAN COIL HEATING COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_1_FLR_6 FAN COIL | ROOM_1_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 2207.095 | 2207.095 | 0.098691 | 0.00001931 | 63.075 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | ROOM_1_FLR_6 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.289510 | 0.33611444 | 4197.9300 | 999.8980 | 4.43258374 | 54.44 | 82.22 | 27.78 | 516921.25 | 0.4270 | 0.435562 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | Sensible | 2207.10 | 2207.10 | 1.0000 | 0.11457830 | 0.098691 | 21.11 | 14.01 | 0.00741860 | 40056.4 | 40.00 | 20.76 | 0.00800000 | 60796.0 | 0.01930666 | 60.00 | 32.22 | 27.78 | 0.000 | 2207.10 | -6.30 | 0.00229779 | -6.30 | 0.00000000 | 0.0000 | 21.11 | 0.00741860 | 21.11 | 0.00741860 | 45.9708 | 2207.15 | 0.00 | 2379.27 | 2379.27 | 0.11457830 | 16.60 | 12.58 | 0.00741860 | 35462.7 | 36.99 | 19.84 | 0.00741860 | 56228.2 | |
ROOM_2_FLR_6 FAN COIL COOLING COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_2_FLR_6 FAN COIL | ROOM_2_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 3516.814 | -999.000 | 0.285908 | 0.00012561 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.1208 | 1004.8586 | 1.1610 | ROOM_2_FLR_6 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.285908 | 0.33193206 | 4197.9300 | 999.8980 | 47.91123978 | 13.37 | 6.70 | 6.67 | 1341523.97 | 0.2622 | 0.262146 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:10:00 | unknown | unknown | unknown | 7/21 17:10:00 | Sensible | 3516.81 | 3330.46 | 1.0000 | 0.33193206 | 0.285908 | 22.54 | 15.72 | 0.00875807 | 44917.2 | 12.80 | 11.77 | 0.00850000 | 34322.2 | 0.12559730 | 6.70 | 13.37 | 6.67 | 0.000 | 3516.81 | 32.91 | 0.01447054 | 23.14 | 0.00000000 | 0.0000 | 21.11 | 0.00875807 | 21.11 | 0.00875807 | 54.1559 | 2815.14 | 0.00 | 3634.19 | 3374.79 | 0.33193206 | 22.54 | 16.09 | 0.00875807 | 44917.2 | 12.58 | 11.96 | 0.00844848 | 33968.6 | |
ROOM_2_FLR_6 FAN COIL HEATING COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_2_FLR_6 FAN COIL | ROOM_2_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 2212.042 | 2212.042 | 0.098913 | 0.00001935 | 63.216 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | ROOM_2_FLR_6 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 0.285908 | 0.33193206 | 4197.9300 | 999.8980 | 4.43258374 | 54.44 | 82.22 | 27.78 | 516921.25 | 0.4279 | 0.436538 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | Sensible | 2212.04 | 2212.04 | 1.0000 | 0.11483510 | 0.098913 | 21.11 | 14.01 | 0.00741981 | 40059.4 | 40.00 | 20.76 | 0.00800000 | 60796.0 | 0.01934993 | 60.00 | 32.22 | 27.78 | 0.000 | 2212.04 | -6.30 | 0.00229779 | -6.30 | 0.00000000 | 0.0000 | 21.11 | 0.00741981 | 21.11 | 0.00741981 | 45.9782 | 2212.09 | 0.00 | 2384.61 | 2384.61 | 0.11483510 | 16.60 | 12.58 | 0.00741981 | 35465.8 | 36.99 | 19.84 | 0.00741981 | 56231.3 | |
ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_3_MULT9_FLR_6 FAN COIL | ROOM_3_MULT9_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 16548.409 | -999.000 | 1.326459 | 0.00059106 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.2312 | 1004.8586 | 1.1610 | ROOM_3_MULT9_FLR_6 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 1.326459 | 1.53998752 | 4197.9300 | 999.8980 | 47.91123978 | 13.37 | 6.70 | 6.67 | 1341523.97 | 1.2336 | 1.233530 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:30:00 | unknown | unknown | unknown | 7/21 14:30:00 | Sensible | 16548.41 | 15482.69 | 1.0000 | 1.53998752 | 1.326459 | 22.54 | 15.77 | 0.00881745 | 45068.0 | 12.80 | 11.77 | 0.00850000 | 34322.2 | 0.59099950 | 6.70 | 13.37 | 6.67 | 0.000 | 16548.41 | 34.40 | 0.01447326 | 23.54 | 0.00000000 | 0.0000 | 21.11 | 0.00881745 | 21.11 | 0.00881745 | 54.5180 | 13060.73 | 0.00 | 17096.89 | 15686.45 | 1.53998752 | 22.54 | 16.14 | 0.00881745 | 45068.0 | 12.56 | 11.96 | 0.00845462 | 33966.0 | |
ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_3_MULT9_FLR_6 FAN COIL | ROOM_3_MULT9_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 10571.409 | 10571.409 | 0.472712 | 0.00009248 | 302.110 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | ROOM_3_MULT9_FLR_6 FAN COIL FAN COILFAN_FAN | Fan:OnOff | 1.326459 | 1.53998752 | 4197.9300 | 999.8980 | 4.43258374 | 54.44 | 82.22 | 27.78 | 516921.25 | 2.0451 | 2.086229 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | Sensible | 10571.41 | 10571.41 | 1.0000 | 0.54880765 | 0.472712 | 21.11 | 14.02 | 0.00743885 | 40108.0 | 40.00 | 20.76 | 0.00800000 | 60796.0 | 0.09247386 | 60.00 | 32.22 | 27.78 | 0.000 | 10571.41 | -6.30 | 0.00229779 | -6.30 | 0.00000000 | 0.0000 | 21.11 | 0.00743885 | 21.11 | 0.00743885 | 46.0940 | 10571.60 | 0.00 | 11396.14 | 11396.14 | 0.54880765 | 16.60 | 12.60 | 0.00743885 | 35514.0 | 36.98 | 19.85 | 0.00743885 | 56279.3 | |
BANQUET_FLR_6 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | Unknown | BANQUET_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 19074.637 | 19074.637 | 2.314415 | 0.00016687 | 411.002 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 4.43258374 | 54.44 | 82.22 | 27.78 | 516921.25 | 3.6900 | 3.764311 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | Sensible | 19074.64 | 19074.64 | 1.0000 | 2.68698109 | 2.314415 | 16.70 | 12.85 | 0.00800000 | 37036.7 | 40.00 | 20.76 | 0.00800000 | 60796.0 | 0.16685622 | 60.00 | 32.22 | 27.78 | 0.000 | 19074.64 | -6.30 | 0.00229779 | -6.30 | 0.00000000 | 0.0000 | 21.00 | 0.00755682 | 21.00 | 0.00755682 | 47.1347 | 7303.68 | 0.00 | 19180.68 | 19180.68 | 2.68698109 | 16.60 | 13.15 | 0.00800000 | 36934.7 | 23.60 | 15.81 | 0.00800000 | 44073.1 | |
DINING_FLR_6 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | Unknown | DINING_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 19787.807 | 19787.807 | 2.428023 | 0.00017311 | 425.953 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 4.43258374 | 54.44 | 82.22 | 27.78 | 516921.25 | 3.8280 | 3.905052 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 11:50:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 11:50:00 | Sensible | 19787.81 | 19787.81 | 1.0000 | 2.81887809 | 2.428023 | 16.70 | 12.85 | 0.00800000 | 37036.7 | 40.00 | 20.76 | 0.00800000 | 60796.0 | 0.17309471 | 60.00 | 32.22 | 27.78 | 0.000 | 19787.81 | -6.30 | 0.00229779 | -6.30 | 0.00000000 | 0.0000 | 21.00 | 0.00756427 | 21.00 | 0.00756427 | 47.1805 | 7438.79 | 0.00 | 19897.84 | 19897.84 | 2.81887809 | 16.60 | 13.15 | 0.00800000 | 36934.7 | 23.52 | 15.78 | 0.00800000 | 43993.5 | |
KITCHEN_FLR_6 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | Unknown | KITCHEN_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 14213.111 | 14213.111 | 2.347212 | 0.00012434 | 299.332 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 4.43258374 | 54.44 | 82.22 | 27.78 | 516921.25 | 2.7496 | 2.804906 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 23:30:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 23:30:00 | Sensible | 14213.11 | 14213.11 | 1.0000 | 2.72505750 | 2.347212 | 16.70 | 12.85 | 0.00800000 | 37036.7 | 40.00 | 20.76 | 0.00800000 | 60796.0 | 0.12432981 | 60.00 | 32.22 | 27.78 | 0.000 | 14213.11 | -6.30 | 0.00229779 | -6.30 | 0.00000000 | 0.0000 | 20.59 | 0.00632950 | 21.00 | 0.00632950 | 39.5654 | 2312.24 | 0.00 | 14292.71 | 14292.71 | 2.72505750 | 16.60 | 13.15 | 0.00800000 | 36934.7 | 21.74 | 15.13 | 0.00800000 | 42179.7 | |
CORRIDOR_FLR_6 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORRIDOR_FLR_6 VAV BOX | CORRIDOR_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 11283.653 | 11283.653 | 0.714338 | 0.00009871 | 264.491 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 4.43258374 | 54.44 | 82.22 | 27.78 | 516921.25 | 2.1829 | 2.226788 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 11:50:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 11:50:00 | Sensible | 11283.65 | 11283.65 | 1.0000 | 0.82932937 | 0.714338 | 16.70 | 12.85 | 0.00800000 | 37036.7 | 40.00 | 20.76 | 0.00800000 | 60796.0 | 0.09870425 | 60.00 | 32.22 | 27.78 | 0.000 | 11283.65 | -6.30 | 0.00229779 | -6.30 | 0.00000000 | 0.0000 | 21.00 | 0.00762451 | 21.00 | 0.00762451 | 47.5513 | 7650.00 | 0.00 | 11343.82 | 11343.82 | 0.82932937 | 16.60 | 13.15 | 0.00800000 | 36934.7 | 30.01 | 18.04 | 0.00800000 | 50613.0 | |
VAV WITH REHEAT COOLING COIL | Coil:Cooling:Water | AirLoop | AirLoopHVAC | VAV WITH REHEAT | BASEMENT; RETAIL_1_FLR_1; RETAIL_2_FLR_1; MECH_FLR_1; STORAGE_FLR_1; LAUNDRY_FLR_1; CAFE_FLR_1; LOBBY_FLR_1; CORRIDOR_FLR_3; CORRIDOR_FLR_6; BANQUET_FLR_6; DINING_FLR_6; KITCHEN_FLR_6; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | Yes | No | 1006896.452 | -999.000 | 22.081900 | 0.03596401 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1031.7451 | 1004.8586 | 1.1610 | VAV WITH REHEAT FAN | Fan:VariableVolume | 22.081900 | 25.63656753 | 4197.9300 | 999.8980 | 47.91123978 | 13.37 | 6.70 | 6.67 | 1341523.97 | 75.0562 | 75.056166 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | Sensible | 1006896.45 | 612915.86 | 1.0000 | 25.63656753 | 22.081900 | 34.40 | 23.54 | 0.01447326 | 71688.8 | 10.93 | 10.93 | 0.00850000 | 32413.0 | 35.96033957 | 6.70 | 13.37 | 6.67 | 49477.557 | 957418.89 | 34.40 | 0.01447326 | 23.54 | 22.07975000 | 99.9903 | 23.99 | 0.00974532 | 23.99 | 0.00977089 | 50.6346 | 292778.63 | 0.00 | 1022938.78 | 614792.33 | 25.63656753 | 34.40 | 23.99 | 0.01447326 | 71688.8 | 11.16 | 11.06 | 0.00815982 | 31787.2 | |
VAV WITH REHEAT HEATING COIL | Coil:Heating:Water | AirLoop | AirLoopHVAC | VAV WITH REHEAT | BASEMENT; RETAIL_1_FLR_1; RETAIL_2_FLR_1; MECH_FLR_1; STORAGE_FLR_1; LAUNDRY_FLR_1; CAFE_FLR_1; LOBBY_FLR_1; CORRIDOR_FLR_3; CORRIDOR_FLR_6; BANQUET_FLR_6; DINING_FLR_6; KITCHEN_FLR_6; | Coincident | HeatingDesignCapacity | N/A | Yes | Yes | Yes | No | 177751.763 | 177751.763 | 6.624570 | 0.00155505 | 3000.095 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | VAV WITH REHEAT FAN | Fan:VariableVolume | 22.081900 | 25.63656753 | 4197.9300 | 999.8980 | 4.43258374 | 54.44 | 82.22 | 27.78 | 516921.25 | 34.3866 | 35.078668 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:00:00 | Sensible | 177751.76 | 177751.76 | 1.0000 | 7.69097026 | 6.624570 | -6.30 | -6.30 | 0.00229779 | -610.8 | 16.70 | 12.85 | 0.00800000 | 37036.7 | 1.55489133 | 60.00 | 32.22 | 27.78 | 0.000 | 177751.76 | -6.30 | 0.00229779 | -6.30 | 22.07975000 | 333.3009 | 20.98 | 0.00739969 | 21.01 | 0.00739373 | 46.1013 | 73464.09 | 0.00 | 159853.92 | 159853.92 | 7.69097026 | 2.80 | -0.72 | 0.00229779 | 8572.2 | 23.40 | 10.14 | 0.00229779 | 29356.8 | |
FLR_3_DOAS COOLING COIL | Coil:Cooling:Water | AirLoop | AirLoopHVAC | FLR_3_DOAS | ROOM_1_FLR_3; ROOM_2_FLR_3; ROOM_3_MULT19_FLR_3; ROOM_4_MULT19_FLR_3; ROOM_5_FLR_3; ROOM_6_FLR_3; ROOM_1_FLR_6; ROOM_2_FLR_6; ROOM_3_MULT9_FLR_6; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | Yes | No | 91161.109 | -999.000 | 2.051317 | 0.00325606 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1031.7451 | 1004.8586 | 1.1610 | FLR_3_DOAS FAN | Fan:ConstantVolume | 2.051245 | 2.38144746 | 4197.9300 | 999.8980 | 47.91123978 | 13.37 | 6.70 | 6.67 | 1341523.97 | 6.7953 | 6.795340 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:30:00 | Sensible | 91161.11 | 55491.40 | 1.0000 | 2.38153119 | 2.051317 | 34.40 | 23.54 | 0.01447326 | 71688.8 | 11.91 | 11.41 | 0.00850000 | 33410.4 | 3.25573143 | 6.70 | 13.37 | 6.67 | 2195.006 | 88966.10 | 34.40 | 0.01447326 | 23.54 | 2.05124512 | 99.9965 | 21.11 | 0.00878831 | 21.11 | 0.00877681 | 54.2682 | 187594.30 | 0.00 | 92644.03 | 56011.80 | 2.38153119 | 34.40 | 23.99 | 0.01447326 | 71688.8 | 11.60 | 11.47 | 0.00837545 | 32787.8 | |
FLR_3_DOAS HEATING COIL | Coil:Heating:Water | AirLoop | AirLoopHVAC | FLR_3_DOAS | ROOM_1_FLR_3; ROOM_2_FLR_3; ROOM_3_MULT19_FLR_3; ROOM_4_MULT19_FLR_3; ROOM_5_FLR_3; ROOM_6_FLR_3; ROOM_1_FLR_6; ROOM_2_FLR_6; ROOM_3_MULT9_FLR_6; | Coincident | HeatingDesignCapacity | N/A | Yes | Yes | Yes | No | 16512.404 | 16512.404 | 0.615395 | 0.00014446 | 278.696 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | FLR_3_DOAS FAN | Fan:ConstantVolume | 2.051245 | 2.38144746 | 4197.9300 | 999.8980 | 4.43258374 | 54.44 | 82.22 | 27.78 | 516921.25 | 3.1944 | 3.258663 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 12:10:00 | Sensible | 16512.40 | 16512.40 | 1.0000 | 0.71445936 | 0.615395 | -6.30 | -6.30 | 0.00229779 | -610.8 | 16.70 | 12.85 | 0.00800000 | 37036.7 | 0.14444298 | 60.00 | 32.22 | 27.78 | 0.000 | 16512.40 | -6.30 | 0.00229779 | -6.30 | 2.05124512 | 333.3216 | 21.11 | 0.00734669 | 21.11 | 0.00734732 | 45.5322 | 125839.70 | 0.00 | 14849.77 | 14849.77 | 0.71445936 | 2.80 | -0.72 | 0.00229779 | 8572.2 | 23.40 | 10.14 | 0.00229779 | 29356.8 |
Report: System Summary
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
VAV WITH REHEAT_OA_CONTROLLER | DifferentialEnthalpy | 22.08 | 22.08 | - | |||
FLR_3_DOAS_OA_CONTROLLER | DifferentialDryBulb | 2.05 | 2.05 | - |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
BASEMENT | VAV WITH REHEAT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
RETAIL_1_FLR_1 | VAV WITH REHEAT_DCV | 0.000000 | 0.001181 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
RETAIL_2_FLR_1 | VAV WITH REHEAT_DCV | 0.000000 | 0.001181 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
MECH_FLR_1 | VAV WITH REHEAT_DCV | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
STORAGE_FLR_1 | VAV WITH REHEAT_DCV | 0.000000 | 0.000610 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
LAUNDRY_FLR_1 | VAV WITH REHEAT_DCV | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
CAFE_FLR_1 | VAV WITH REHEAT_DCV | 0.000000 | 0.003581 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
LOBBY_FLR_1 | VAV WITH REHEAT_DCV | 0.000000 | 0.001448 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
CORRIDOR_FLR_3 | VAV WITH REHEAT_DCV | 0.000000 | 0.000305 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
BANQUET_FLR_6 | VAV WITH REHEAT_DCV | 0.000000 | 0.003581 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
DINING_FLR_6 | VAV WITH REHEAT_DCV | 0.000000 | 0.003581 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
KITCHEN_FLR_6 | VAV WITH REHEAT_DCV | 0.000000 | 0.003556 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
CORRIDOR_FLR_6 | VAV WITH REHEAT_DCV | 0.000000 | 0.000305 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
BASEMENT | 229.50 | 8760.00 | 229.50 |
RETAIL_1_FLR_1 | 1119.33 | 8714.83 | 1112.00 |
RETAIL_2_FLR_1 | 229.83 | 8760.00 | 229.83 |
MECH_FLR_1 | 871.33 | 8760.00 | 871.33 |
STORAGE_FLR_1 | 1158.50 | 8760.00 | 1158.50 |
LAUNDRY_FLR_1 | 4248.50 | 3708.00 | 1150.17 |
CAFE_FLR_1 | 335.83 | 8691.33 | 328.00 |
LOBBY_FLR_1 | 37.83 | 8760.00 | 37.83 |
ROOM_1_FLR_3 | 1606.50 | 8147.00 | 1527.00 |
ROOM_2_FLR_3 | 2012.50 | 8242.67 | 1956.83 |
ROOM_3_MULT19_FLR_3 | 0.00 | 0.00 | 0.00 |
ROOM_4_MULT19_FLR_3 | 1076.50 | 8760.00 | 1076.50 |
ROOM_5_FLR_3 | 1479.17 | 8013.33 | 1461.00 |
ROOM_6_FLR_3 | 1854.17 | 8127.83 | 1843.50 |
CORRIDOR_FLR_3 | 890.17 | 8760.00 | 890.17 |
ROOM_1_FLR_6 | 2297.50 | 7974.00 | 1970.50 |
ROOM_2_FLR_6 | 2610.00 | 8062.50 | 2355.33 |
ROOM_3_MULT9_FLR_6 | 1075.67 | 8008.50 | 1017.17 |
BANQUET_FLR_6 | 297.00 | 8046.50 | 28.50 |
DINING_FLR_6 | 493.17 | 7567.67 | 3.83 |
KITCHEN_FLR_6 | 6860.00 | 6316.83 | 5046.67 |
CORRIDOR_FLR_6 | 1217.33 | 8760.00 | 1217.33 |
Facility | 7721.67 | 8760.00 | 6613.67 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
BASEMENT | 1.67 | 0.00 | 1.67 | 0.00 |
RETAIL_1_FLR_1 | 13.83 | 0.00 | 13.83 | 0.00 |
RETAIL_2_FLR_1 | 0.00 | 0.00 | 0.00 | 0.00 |
MECH_FLR_1 | 0.00 | 0.00 | 0.00 | 0.00 |
STORAGE_FLR_1 | 0.00 | 0.00 | 0.00 | 0.00 |
LAUNDRY_FLR_1 | 0.00 | 0.33 | 0.00 | 0.33 |
CAFE_FLR_1 | 0.00 | 0.00 | 0.00 | 0.00 |
LOBBY_FLR_1 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_3 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_3 | 0.50 | 0.17 | 0.50 | 0.17 |
ROOM_3_MULT19_FLR_3 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_4_MULT19_FLR_3 | 1.17 | 2.00 | 1.17 | 2.00 |
ROOM_5_FLR_3 | 0.33 | 0.00 | 0.33 | 0.00 |
ROOM_6_FLR_3 | 0.33 | 0.00 | 0.33 | 0.00 |
CORRIDOR_FLR_3 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_6 | 0.50 | 1.17 | 0.50 | 1.17 |
ROOM_2_FLR_6 | 0.83 | 0.33 | 0.83 | 0.33 |
ROOM_3_MULT9_FLR_6 | 0.17 | 4.83 | 0.17 | 4.83 |
BANQUET_FLR_6 | 0.00 | 0.00 | 0.00 | 0.00 |
DINING_FLR_6 | 0.00 | 0.00 | 0.00 | 0.00 |
KITCHEN_FLR_6 | 0.00 | 3.00 | 0.00 | 3.00 |
CORRIDOR_FLR_6 | 4.67 | 0.00 | 4.67 | 0.00 |
Facility | 17.50 | 10.17 | 17.50 | 10.17 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BASEMENT | 61.80 | 106.50 | 4826.41 | 1.879 | 0.000 | 0.000 | 0.000 |
RETAIL_1_FLR_1 | 6.28 | 10.83 | 265.76 | 4.596 | 0.242 | 0.000 | 0.000 |
RETAIL_2_FLR_1 | 7.28 | 12.54 | 307.76 | 2.942 | 0.081 | 0.000 | 0.000 |
MECH_FLR_1 | 1.54 | 2.65 | 650.80 | 1.465 | 0.090 | 0.000 | 0.000 |
STORAGE_FLR_1 | 1.18 | 2.04 | 375.47 | 1.267 | 0.090 | 0.000 | 0.000 |
LAUNDRY_FLR_1 | 4.87 | 8.40 | 309.22 | 39.790 | 0.260 | 0.000 | 0.000 |
CAFE_FLR_1 | 82.58 | 142.30 | 748.35 | 7.056 | 0.190 | 0.000 | 0.000 |
LOBBY_FLR_1 | 245.14 | 422.44 | 5183.56 | 3.384 | 0.079 | 0.000 | 0.000 |
ROOM_1_FLR_3 | 0.95 | 1.50 | 118.94 | 0.473 | 0.315 | 0.000 | 0.068 |
ROOM_2_FLR_3 | 0.95 | 1.50 | 118.93 | 0.472 | 0.315 | 0.000 | 0.066 |
ROOM_3_MULT19_FLR_3 | 1.50 | 74.75 | |||||
ROOM_4_MULT19_FLR_3 | 0.95 | 1.50 | 74.77 | 0.536 | 0.140 | 0.000 | 0.105 |
ROOM_5_FLR_3 | 0.95 | 1.50 | 118.94 | 0.473 | 0.315 | 0.000 | 0.068 |
ROOM_6_FLR_3 | 0.95 | 1.50 | 118.93 | 0.473 | 0.315 | 0.000 | 0.066 |
CORRIDOR_FLR_3 | 12.16 | 20.96 | 1186.91 | 0.887 | 0.038 | 0.000 | 0.000 |
ROOM_1_FLR_6 | 0.95 | 1.50 | 118.94 | 0.473 | 0.315 | 0.000 | 0.081 |
ROOM_2_FLR_6 | 0.95 | 1.50 | 118.93 | 0.472 | 0.315 | 0.000 | 0.079 |
ROOM_3_MULT9_FLR_6 | 0.95 | 1.50 | 74.77 | 0.537 | 0.256 | 0.000 | 0.129 |
BANQUET_FLR_6 | 145.01 | 249.90 | 1010.89 | 8.346 | 0.091 | 0.000 | 0.000 |
DINING_FLR_6 | 145.01 | 249.90 | 1010.89 | 8.757 | 0.091 | 0.000 | 0.000 |
KITCHEN_FLR_6 | 12.90 | 22.24 | 314.87 | 27.337 | 0.261 | 0.000 | 0.000 |
CORRIDOR_FLR_6 | 12.87 | 22.18 | 1256.16 | 2.068 | 0.064 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BASEMENT | 61.80 | 106.50 | 4826.41 | 1.816 | 0.000 | 0.000 | 0.000 |
RETAIL_1_FLR_1 | 6.28 | 10.83 | 265.76 | 4.441 | 0.005 | 0.000 | 0.000 |
RETAIL_2_FLR_1 | 7.28 | 12.54 | 307.76 | 2.843 | 0.002 | 0.000 | 0.000 |
MECH_FLR_1 | 1.54 | 2.65 | 650.80 | 1.417 | 0.002 | 0.000 | 0.000 |
STORAGE_FLR_1 | 1.18 | 2.04 | 375.47 | 1.225 | 0.002 | 0.000 | 0.000 |
LAUNDRY_FLR_1 | 4.87 | 8.40 | 309.22 | 38.436 | 0.005 | 0.000 | 0.000 |
CAFE_FLR_1 | 82.58 | 142.30 | 748.35 | 6.814 | 0.004 | 0.000 | 0.000 |
LOBBY_FLR_1 | 245.14 | 422.44 | 5183.56 | 3.268 | 0.002 | 0.000 | 0.000 |
ROOM_1_FLR_3 | 0.95 | 1.50 | 118.94 | 0.454 | 0.006 | 0.000 | 0.000 |
ROOM_2_FLR_3 | 0.95 | 1.50 | 118.93 | 0.454 | 0.006 | 0.000 | 0.000 |
ROOM_3_MULT19_FLR_3 | 1.50 | 74.75 | |||||
ROOM_4_MULT19_FLR_3 | 0.95 | 1.50 | 74.77 | 0.516 | 0.003 | 0.000 | 0.000 |
ROOM_5_FLR_3 | 0.95 | 1.50 | 118.94 | 0.454 | 0.006 | 0.000 | 0.000 |
ROOM_6_FLR_3 | 0.95 | 1.50 | 118.93 | 0.454 | 0.006 | 0.000 | 0.000 |
CORRIDOR_FLR_3 | 12.16 | 20.96 | 1186.91 | 0.857 | 0.001 | 0.000 | 0.000 |
ROOM_1_FLR_6 | 0.95 | 1.50 | 118.94 | 0.454 | 0.006 | 0.000 | 0.000 |
ROOM_2_FLR_6 | 0.95 | 1.50 | 118.93 | 0.454 | 0.006 | 0.000 | 0.000 |
ROOM_3_MULT9_FLR_6 | 0.95 | 1.50 | 74.77 | 0.516 | 0.005 | 0.000 | 0.000 |
BANQUET_FLR_6 | 145.01 | 249.90 | 1010.89 | 8.049 | 0.002 | 0.000 | 0.000 |
DINING_FLR_6 | 145.01 | 249.90 | 1010.89 | 8.444 | 0.002 | 0.000 | 0.000 |
KITCHEN_FLR_6 | 12.90 | 22.24 | 314.87 | 26.289 | 0.005 | 0.000 | 0.000 |
CORRIDOR_FLR_6 | 12.87 | 22.18 | 1256.16 | 1.997 | 0.001 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
Mechanical Ventilation Parameters by ZoneAirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
BASEMENT | VAV WITH REHEAT | 61.80 | 106.50 | 4826.41 | 1978.83 | 0.0000 | 0.854 |
RETAIL_1_FLR_1 | VAV WITH REHEAT | 6.28 | 10.83 | 265.76 | 67.07 | 0.0000 | 0.079 |
RETAIL_2_FLR_1 | VAV WITH REHEAT | 7.28 | 12.54 | 307.76 | 77.67 | 0.0000 | 0.092 |
MECH_FLR_1 | VAV WITH REHEAT | 1.54 | 2.65 | 650.80 | 164.24 | 0.0000 | 0.000 |
STORAGE_FLR_1 | VAV WITH REHEAT | 1.18 | 2.04 | 375.47 | 94.76 | 0.0000 | 0.058 |
LAUNDRY_FLR_1 | VAV WITH REHEAT | 4.87 | 8.40 | 309.22 | 78.04 | 0.0000 | 0.000 |
CAFE_FLR_1 | VAV WITH REHEAT | 82.58 | 142.30 | 748.35 | 188.86 | 0.0000 | 0.676 |
LOBBY_FLR_1 | VAV WITH REHEAT | 245.14 | 422.44 | 5183.56 | 1308.19 | 0.0000 | 1.894 |
ROOM_1_FLR_3 | FLR_3_DOAS | 0.95 | 1.50 | 118.94 | 39.02 | 0.0000 | 0.062 |
ROOM_2_FLR_3 | FLR_3_DOAS | 0.95 | 1.50 | 118.93 | 39.02 | 0.0000 | 0.062 |
ROOM_3_MULT19_FLR_3 | FLR_3_DOAS | 1.50 | 74.75 | 24.52 | 0.0000 | 0.837 | |
ROOM_4_MULT19_FLR_3 | FLR_3_DOAS | 0.95 | 1.50 | 74.77 | 24.53 | 0.0000 | 0.837 |
ROOM_5_FLR_3 | FLR_3_DOAS | 0.95 | 1.50 | 118.94 | 39.02 | 0.0000 | 0.062 |
ROOM_6_FLR_3 | FLR_3_DOAS | 0.95 | 1.50 | 118.93 | 39.02 | 0.0000 | 0.062 |
CORRIDOR_FLR_3 | VAV WITH REHEAT | 12.16 | 20.96 | 1186.91 | 389.40 | 0.0000 | 0.475 |
ROOM_1_FLR_6 | FLR_3_DOAS | 0.95 | 1.50 | 118.94 | 39.02 | 0.0000 | 0.015 |
ROOM_2_FLR_6 | FLR_3_DOAS | 0.95 | 1.50 | 118.93 | 39.02 | 0.0000 | 0.015 |
ROOM_3_MULT9_FLR_6 | FLR_3_DOAS | 0.95 | 1.50 | 74.77 | 24.53 | 0.0000 | 0.099 |
BANQUET_FLR_6 | VAV WITH REHEAT | 145.01 | 249.90 | 1010.89 | 331.66 | 0.0000 | 1.188 |
DINING_FLR_6 | VAV WITH REHEAT | 145.01 | 249.90 | 1010.89 | 331.66 | 0.0000 | 1.188 |
KITCHEN_FLR_6 | VAV WITH REHEAT | 12.90 | 22.24 | 314.87 | 103.30 | 0.0000 | 0.367 |
CORRIDOR_FLR_6 | VAV WITH REHEAT | 12.87 | 22.18 | 1256.16 | 412.12 | 0.0000 | 0.126 |
Total Facility | 873.39 | 1604.23 | 35184.81 | 11345.29 | 0.0000 | 137.584 |
Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
BASEMENT | 78593958.21 | 0.00 | 78593958.21 | 0.00 | 78593958.21 | 26946214.98 | 0.00 | 0.00 | 8760.00 | 0.00 |
RETAIL_1_FLR_1 | 10591870.70 | 0.00 | 10591870.70 | 558397.54 | 11150268.24 | 2498216.28 | 0.00 | 0.00 | 8760.00 | 0.00 |
RETAIL_2_FLR_1 | 7847921.21 | 0.00 | 7847921.21 | 215542.16 | 8063463.36 | 2892943.94 | 0.00 | 0.00 | 8760.00 | 0.00 |
MECH_FLR_1 | 8272393.90 | 0.00 | 8272393.90 | 509413.61 | 8781807.51 | 0.00 | 0.00 | 0.00 | 8760.00 | 0.00 |
STORAGE_FLR_1 | 4126710.87 | 0.00 | 4126710.87 | 293903.59 | 4420614.46 | 1821682.01 | 0.00 | 0.00 | 8760.00 | 0.00 |
LAUNDRY_FLR_1 | 0.11E+09 | 0.00 | 0.11E+09 | 695578.26 | 0.11E+09 | 0.00 | 0.00 | 0.00 | 8760.00 | 0.00 |
CAFE_FLR_1 | 45732977.21 | 0.00 | 45732977.21 | 1234369.37 | 46967346.58 | 21330615.53 | 0.00 | 0.00 | 8760.00 | 0.00 |
LOBBY_FLR_1 | 0.15E+09 | 0.00 | 0.15E+09 | 3526875.24 | 0.16E+09 | 59728886.00 | 0.00 | 0.00 | 8760.00 | 0.00 |
ROOM_1_FLR_3 | 1946875.62 | 69636.60 | 2016512.22 | 324110.12 | 2340622.33 | 1946875.62 | 0.00 | 7631.17 | 1128.83 | 0.00 |
ROOM_2_FLR_3 | 1946647.51 | 67677.61 | 2014325.12 | 324085.39 | 2338410.51 | 1946647.51 | 0.00 | 7631.17 | 1128.83 | 0.00 |
ROOM_3_MULT19_FLR_3 | 26397887.27 | 74523.38 | 26472410.65 | 90430.36 | 26562841.01 | 26397887.27 | 0.00 | 7683.33 | 1076.67 | 8760.00 |
ROOM_4_MULT19_FLR_3 | 26405105.73 | 67630.55 | 26472736.28 | 90455.09 | 26563191.36 | 26405105.73 | 0.00 | 7694.20 | 1065.80 | 0.00 |
ROOM_5_FLR_3 | 1946875.62 | 69716.04 | 2016591.65 | 324110.12 | 2340701.77 | 1946875.62 | 0.00 | 7631.17 | 1128.83 | 0.00 |
ROOM_6_FLR_3 | 1946647.51 | 67736.20 | 2014383.72 | 324085.39 | 2338469.10 | 1946647.51 | 0.00 | 7631.21 | 1128.79 | 0.00 |
CORRIDOR_FLR_3 | 36480178.35 | 0.00 | 36480178.35 | 391914.34 | 36872092.69 | 14972100.18 | 0.00 | 0.00 | 8760.00 | 0.00 |
ROOM_1_FLR_6 | 486718.90 | 83499.99 | 570218.90 | 324176.76 | 894395.66 | 486718.90 | 0.00 | 7626.50 | 1133.50 | 0.00 |
ROOM_2_FLR_6 | 486661.88 | 80909.39 | 567571.27 | 324152.03 | 891723.30 | 486661.88 | 0.00 | 7626.50 | 1133.50 | 0.00 |
ROOM_3_MULT9_FLR_6 | 3126920.42 | 83545.48 | 3210465.90 | 165860.18 | 3376326.08 | 3126920.42 | 0.00 | 7626.50 | 1133.50 | 0.00 |
BANQUET_FLR_6 | 72971223.32 | 0.00 | 72971223.32 | 791558.19 | 73762781.51 | 37458366.31 | 0.00 | 0.00 | 8760.00 | 0.00 |
DINING_FLR_6 | 76553193.13 | 0.00 | 76553193.13 | 791558.19 | 77344751.32 | 37458366.31 | 0.00 | 0.00 | 8760.00 | 0.00 |
KITCHEN_FLR_6 | 74087302.47 | 0.00 | 74087302.47 | 708628.10 | 74795930.57 | 11584760.86 | 0.00 | 0.00 | 8760.00 | 0.00 |
CORRIDOR_FLR_6 | 22522368.74 | 0.00 | 22522368.74 | 693565.64 | 23215934.38 | 3961413.96 | 0.00 | 0.00 | 8760.00 | 0.00 |
Total Facility | 0.49E+10 | 12819083.24 | 0.49E+10 | 32660975.26 | 0.49E+10 | 0.43E+10 | 0.00 | 7733.41 | 8760.00 | 8760.00 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
BASEMENT | 2.4922 | 0.0000 | 2.4922 | 0.0000 | 2.4922 | 0.8545 | 0.00 | 0.00 | 8760.00 |
RETAIL_1_FLR_1 | 0.3359 | 0.0000 | 0.3359 | 0.0177 | 0.3536 | 0.0792 | 0.00 | 0.00 | 8760.00 |
RETAIL_2_FLR_1 | 0.2489 | 0.0000 | 0.2489 | 0.0068 | 0.2557 | 0.0917 | 0.00 | 0.00 | 8760.00 |
MECH_FLR_1 | 0.2623 | 0.0000 | 0.2623 | 0.0162 | 0.2785 | 0.0000 | 0.00 | 0.00 | 8760.00 |
STORAGE_FLR_1 | 0.1309 | 0.0000 | 0.1309 | 0.0093 | 0.1402 | 0.0578 | 0.00 | 0.00 | 8760.00 |
LAUNDRY_FLR_1 | 3.3808 | 0.0000 | 3.3808 | 0.0221 | 3.4029 | 0.0000 | 0.00 | 0.00 | 8760.00 |
CAFE_FLR_1 | 1.4502 | 0.0000 | 1.4502 | 0.0391 | 1.4893 | 0.6764 | 0.00 | 0.00 | 8760.00 |
LOBBY_FLR_1 | 4.8175 | 0.0000 | 4.8175 | 0.1118 | 4.9293 | 1.8940 | 0.00 | 0.00 | 8760.00 |
ROOM_1_FLR_3 | 0.0617 | 0.0022 | 0.0639 | 0.0103 | 0.0742 | 0.0617 | 0.00 | 7631.17 | 1128.83 |
ROOM_2_FLR_3 | 0.0617 | 0.0021 | 0.0639 | 0.0103 | 0.0742 | 0.0617 | 0.00 | 7631.17 | 1128.83 |
ROOM_4_MULT19_FLR_3 | 0.8373 | 0.0021 | 0.8394 | 0.0029 | 0.8423 | 0.8373 | 0.00 | 7694.20 | 1065.80 |
ROOM_5_FLR_3 | 0.0617 | 0.0022 | 0.0639 | 0.0103 | 0.0742 | 0.0617 | 0.00 | 7631.17 | 1128.83 |
ROOM_6_FLR_3 | 0.0617 | 0.0021 | 0.0639 | 0.0103 | 0.0742 | 0.0617 | 0.00 | 7631.21 | 1128.79 |
CORRIDOR_FLR_3 | 1.1568 | 0.0000 | 1.1568 | 0.0124 | 1.1692 | 0.4748 | 0.00 | 0.00 | 8760.00 |
ROOM_1_FLR_6 | 0.0154 | 0.0026 | 0.0181 | 0.0103 | 0.0284 | 0.0154 | 0.00 | 7626.50 | 1133.50 |
ROOM_2_FLR_6 | 0.0154 | 0.0026 | 0.0180 | 0.0103 | 0.0283 | 0.0154 | 0.00 | 7626.50 | 1133.50 |
ROOM_3_MULT9_FLR_6 | 0.0992 | 0.0026 | 0.1018 | 0.0053 | 0.1071 | 0.0992 | 0.00 | 7626.50 | 1133.50 |
BANQUET_FLR_6 | 2.3139 | 0.0000 | 2.3139 | 0.0251 | 2.3390 | 1.1878 | 0.00 | 0.00 | 8760.00 |
DINING_FLR_6 | 2.4275 | 0.0000 | 2.4275 | 0.0251 | 2.4526 | 1.1878 | 0.00 | 0.00 | 8760.00 |
KITCHEN_FLR_6 | 2.3493 | 0.0000 | 2.3493 | 0.0225 | 2.3718 | 0.3674 | 0.00 | 0.00 | 8760.00 |
CORRIDOR_FLR_6 | 0.7142 | 0.0000 | 0.7142 | 0.0220 | 0.7362 | 0.1256 | 0.00 | 0.00 | 8760.00 |
Total Facility | 91.0963 | 0.2269 | 91.3232 | 0.8177 | 92.1410 | 73.9670 | 0.00 | 7733.41 | 8760.00 |
Mechanical Ventilation [m3] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
VAV WITH REHEAT | 0.94E+09 | 0.00 | 0.94E+09 | 0.22E+09 | 0.00 | 0.00 | 8760.00 | 0.00 |
FLR_3_DOAS | 87193944.56 | 664875.25 | 87858819.81 | 64690340.46 | 0.00 | 0.00 | 8760.00 | 0.00 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
VAV WITH REHEAT | 29.7612 | 0.0000 | 29.7612 | 6.9969 | 0.00 | 0.00 | 8760.00 |
FLR_3_DOAS | 2.7649 | 0.0211 | 2.7860 | 2.0513 | 0.00 | 0.00 | 8760.00 |
No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
VAV WITH REHEAT | 0.00 | 8063.96 | 666.95 | 0.00 | 29.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
FLR_3_DOAS | 0.00 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
VAV WITH REHEAT | 0.0000 | 29.7646 | 29.8058 | 0.0000 | 29.8469 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
FLR_3_DOAS | 0.0000 | 2.7649 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
Surfaces by ClassTotal | Outdoors | |
Wall | 119 | 44 |
Floor | 25 | 0 |
Roof | 33 | 11 |
Internal Mass | 22 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 30 | 30 |
Door | 6 | 6 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 2 |
Conditioned Zones | 22 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 1306 |
Defaulted Fields | 1181 |
Fields with Defaults | 3945 |
Autosized Fields | 350 |
Autosizable Fields | 402 |
Autocalculated Fields | 280 |
Autocalculatable Fields | 539 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 9157.43 | 132346.64 | 27-NOV-02:50 | 598806.25 | 02-AUG-19:40 |
Electricity:Building | 2943.68 | 36656.90 | 02-JAN-02:10 | 182730.36 | 02-JAN-20:10 |
Electricity:Zone:BASEMENT | 315.54 | 3631.19 | 02-JAN-02:10 | 23630.80 | 02-JAN-20:10 |
Electricity:SpaceType:GENERAL | 2925.41 | 36182.64 | 02-JAN-02:10 | 182063.43 | 02-JAN-20:10 |
InteriorLights:Electricity | 1174.11 | 10291.59 | 02-JAN-02:10 | 93091.76 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:BASEMENT | 165.29 | 1501.97 | 02-JAN-02:10 | 13517.00 | 02-JAN-20:10 |
InteriorLights:Electricity:SpaceType:GENERAL | 1174.11 | 10291.59 | 02-JAN-02:10 | 93091.76 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity | 1174.11 | 10291.59 | 02-JAN-02:10 | 93091.76 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:Zone:BASEMENT | 165.29 | 1501.97 | 02-JAN-02:10 | 13517.00 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:SpaceType:GENERAL | 1174.11 | 10291.59 | 02-JAN-02:10 | 93091.76 | 02-JAN-20:10 |
Electricity:Zone:RETAIL_1_FLR_1 | 18.59 | 220.70 | 02-JAN-02:10 | 1372.90 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:RETAIL_1_FLR_1 | 8.40 | 76.37 | 02-JAN-02:10 | 687.30 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:Zone:RETAIL_1_FLR_1 | 8.40 | 76.37 | 02-JAN-02:10 | 687.30 | 02-JAN-20:10 |
Electricity:Zone:RETAIL_2_FLR_1 | 21.53 | 255.58 | 02-JAN-02:10 | 1589.82 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:RETAIL_2_FLR_1 | 9.73 | 88.43 | 02-JAN-02:10 | 795.89 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:Zone:RETAIL_2_FLR_1 | 9.73 | 88.43 | 02-JAN-02:10 | 795.89 | 02-JAN-20:10 |
Electricity:Zone:MECH_FLR_1 | 30.66 | 342.02 | 02-JAN-02:10 | 2327.13 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:MECH_FLR_1 | 18.19 | 165.30 | 02-JAN-02:10 | 1487.69 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:Zone:MECH_FLR_1 | 18.19 | 165.30 | 02-JAN-02:10 | 1487.69 | 02-JAN-20:10 |
Electricity:Zone:STORAGE_FLR_1 | 6.94 | 81.32 | 02-JAN-02:10 | 515.26 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:STORAGE_FLR_1 | 3.34 | 30.34 | 02-JAN-02:10 | 273.10 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:Zone:STORAGE_FLR_1 | 3.34 | 30.34 | 02-JAN-02:10 | 273.10 | 02-JAN-20:10 |
Electricity:Zone:LAUNDRY_FLR_1 | 72.06 | 1000.18 | 02-JAN-02:10 | 4910.17 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:LAUNDRY_FLR_1 | 4.13 | 37.49 | 02-JAN-02:10 | 337.37 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:Zone:LAUNDRY_FLR_1 | 4.13 | 37.49 | 02-JAN-02:10 | 337.37 | 02-JAN-20:10 |
Electricity:Zone:CAFE_FLR_1 | 40.96 | 445.13 | 02-JAN-02:10 | 3142.50 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:CAFE_FLR_1 | 26.62 | 241.91 | 02-JAN-02:10 | 2177.23 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:Zone:CAFE_FLR_1 | 26.62 | 241.91 | 02-JAN-02:10 | 2177.23 | 02-JAN-20:10 |
Electricity:Zone:LOBBY_FLR_1 | 293.89 | 3428.00 | 02-JAN-02:10 | 21878.53 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:LOBBY_FLR_1 | 144.90 | 1316.59 | 02-JAN-02:10 | 11849.32 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:Zone:LOBBY_FLR_1 | 144.90 | 1316.59 | 02-JAN-02:10 | 11849.32 | 02-JAN-20:10 |
Electricity:Zone:ROOM_1_FLR_3 | 32.70 | 383.52 | 01-JAN-02:10 | 2308.42 | 01-JAN-21:10 |
InteriorLights:Electricity:Zone:ROOM_1_FLR_3 | 20.41 | 172.80 | 01-JAN-02:10 | 1570.91 | 01-JAN-19:10 |
LightsWired:InteriorLights:Electricity:Zone:ROOM_1_FLR_3 | 20.41 | 172.80 | 01-JAN-02:10 | 1570.91 | 01-JAN-19:10 |
Electricity:Zone:ROOM_2_FLR_3 | 32.70 | 383.47 | 01-JAN-02:10 | 2308.15 | 01-JAN-21:10 |
InteriorLights:Electricity:Zone:ROOM_2_FLR_3 | 20.41 | 172.78 | 01-JAN-02:10 | 1570.72 | 01-JAN-19:10 |
LightsWired:InteriorLights:Electricity:Zone:ROOM_2_FLR_3 | 20.41 | 172.78 | 01-JAN-02:10 | 1570.72 | 01-JAN-19:10 |
Electricity:Zone:ROOM_3_MULT19_FLR_3 | 472.46 | 5984.83 | 01-JAN-02:10 | 32482.97 | 01-JAN-21:10 |
InteriorLights:Electricity:Zone:ROOM_3_MULT19_FLR_3 | 243.71 | 2063.36 | 01-JAN-02:10 | 18757.86 | 01-JAN-19:10 |
LightsWired:InteriorLights:Electricity:Zone:ROOM_3_MULT19_FLR_3 | 243.71 | 2063.36 | 01-JAN-02:10 | 18757.86 | 01-JAN-19:10 |
Electricity:Zone:ROOM_4_MULT19_FLR_3 | 472.59 | 5986.46 | 01-JAN-02:10 | 32491.86 | 01-JAN-21:10 |
InteriorLights:Electricity:Zone:ROOM_4_MULT19_FLR_3 | 243.77 | 2063.93 | 01-JAN-02:10 | 18762.99 | 01-JAN-19:10 |
LightsWired:InteriorLights:Electricity:Zone:ROOM_4_MULT19_FLR_3 | 243.77 | 2063.93 | 01-JAN-02:10 | 18762.99 | 01-JAN-19:10 |
Electricity:Zone:ROOM_5_FLR_3 | 32.70 | 383.52 | 01-JAN-02:10 | 2308.42 | 01-JAN-21:10 |
InteriorLights:Electricity:Zone:ROOM_5_FLR_3 | 20.41 | 172.80 | 01-JAN-02:10 | 1570.91 | 01-JAN-19:10 |
LightsWired:InteriorLights:Electricity:Zone:ROOM_5_FLR_3 | 20.41 | 172.80 | 01-JAN-02:10 | 1570.91 | 01-JAN-19:10 |
Electricity:Zone:ROOM_6_FLR_3 | 32.70 | 383.47 | 01-JAN-02:10 | 2308.15 | 01-JAN-21:10 |
InteriorLights:Electricity:Zone:ROOM_6_FLR_3 | 20.41 | 172.78 | 01-JAN-02:10 | 1570.72 | 01-JAN-19:10 |
LightsWired:InteriorLights:Electricity:Zone:ROOM_6_FLR_3 | 20.41 | 172.78 | 01-JAN-02:10 | 1570.72 | 01-JAN-19:10 |
Electricity:Zone:CORRIDOR_FLR_3 | 62.74 | 570.05 | 02-JAN-02:10 | 5130.41 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:CORRIDOR_FLR_3 | 62.74 | 570.05 | 02-JAN-02:10 | 5130.41 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:Zone:CORRIDOR_FLR_3 | 62.74 | 570.05 | 02-JAN-02:10 | 5130.41 | 02-JAN-20:10 |
Electricity:Zone:ROOM_1_FLR_6 | 8.18 | 95.88 | 01-JAN-02:10 | 577.11 | 01-JAN-21:10 |
InteriorLights:Electricity:Zone:ROOM_1_FLR_6 | 5.10 | 43.20 | 01-JAN-02:10 | 392.73 | 01-JAN-19:10 |
LightsWired:InteriorLights:Electricity:Zone:ROOM_1_FLR_6 | 5.10 | 43.20 | 01-JAN-02:10 | 392.73 | 01-JAN-19:10 |
Electricity:Zone:ROOM_2_FLR_6 | 8.17 | 95.87 | 01-JAN-02:10 | 577.04 | 01-JAN-21:10 |
InteriorLights:Electricity:Zone:ROOM_2_FLR_6 | 5.10 | 43.19 | 01-JAN-02:10 | 392.68 | 01-JAN-19:10 |
LightsWired:InteriorLights:Electricity:Zone:ROOM_2_FLR_6 | 5.10 | 43.19 | 01-JAN-02:10 | 392.68 | 01-JAN-19:10 |
Electricity:Zone:ROOM_3_MULT9_FLR_6 | 55.96 | 708.92 | 01-JAN-02:10 | 3847.72 | 01-JAN-21:10 |
InteriorLights:Electricity:Zone:ROOM_3_MULT9_FLR_6 | 28.87 | 244.41 | 01-JAN-02:10 | 2221.93 | 01-JAN-19:10 |
LightsWired:InteriorLights:Electricity:Zone:ROOM_3_MULT9_FLR_6 | 28.87 | 244.41 | 01-JAN-02:10 | 2221.93 | 01-JAN-19:10 |
Electricity:Zone:BANQUET_FLR_6 | 222.61 | 2674.12 | 02-JAN-02:10 | 10571.30 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:BANQUET_FLR_6 | 46.75 | 424.82 | 02-JAN-02:10 | 3823.39 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:Zone:BANQUET_FLR_6 | 46.75 | 424.82 | 02-JAN-02:10 | 3823.39 | 02-JAN-20:10 |
Electricity:Zone:DINING_FLR_6 | 222.61 | 2674.12 | 02-JAN-02:10 | 10571.30 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:DINING_FLR_6 | 46.75 | 424.82 | 02-JAN-02:10 | 3823.39 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:Zone:DINING_FLR_6 | 46.75 | 424.82 | 02-JAN-02:10 | 3823.39 | 02-JAN-20:10 |
Electricity:Zone:KITCHEN_FLR_6 | 470.78 | 6777.71 | 02-JAN-02:10 | 19298.76 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:KITCHEN_FLR_6 | 12.48 | 113.42 | 02-JAN-02:10 | 1020.78 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:Zone:KITCHEN_FLR_6 | 12.48 | 113.42 | 02-JAN-02:10 | 1020.78 | 02-JAN-20:10 |
Electricity:Zone:CORRIDOR_FLR_6 | 16.60 | 150.83 | 02-JAN-02:10 | 1357.44 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:CORRIDOR_FLR_6 | 16.60 | 150.83 | 02-JAN-02:10 | 1357.44 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity:Zone:CORRIDOR_FLR_6 | 16.60 | 150.83 | 02-JAN-02:10 | 1357.44 | 02-JAN-20:10 |
InteriorEquipment:Electricity | 1751.30 | 25891.05 | 02-JAN-02:10 | 89674.66 | 02-JAN-07:10 |
InteriorEquipment:Electricity:Zone:BASEMENT | 150.26 | 2129.22 | 02-JAN-02:10 | 10113.80 | 02-JAN-20:10 |
InteriorEquipment:Electricity:SpaceType:GENERAL | 1751.30 | 25891.05 | 02-JAN-02:10 | 89674.66 | 02-JAN-07:10 |
MiscPlug:InteriorEquipment:Electricity | 959.56 | 15202.41 | 02-JAN-02:10 | 59492.27 | 02-JAN-07:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:BASEMENT | 150.26 | 2129.22 | 02-JAN-02:10 | 10113.80 | 02-JAN-20:10 |
MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL | 959.56 | 15202.41 | 02-JAN-02:10 | 59492.27 | 02-JAN-07:10 |
InteriorEquipment:Electricity:Zone:RETAIL_1_FLR_1 | 10.19 | 144.34 | 02-JAN-02:10 | 685.60 | 02-JAN-20:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:RETAIL_1_FLR_1 | 10.19 | 144.34 | 02-JAN-02:10 | 685.60 | 02-JAN-20:10 |
InteriorEquipment:Electricity:Zone:RETAIL_2_FLR_1 | 11.79 | 167.14 | 02-JAN-02:10 | 793.93 | 02-JAN-20:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:RETAIL_2_FLR_1 | 11.79 | 167.14 | 02-JAN-02:10 | 793.93 | 02-JAN-20:10 |
InteriorEquipment:Electricity:Zone:MECH_FLR_1 | 12.47 | 176.73 | 02-JAN-02:10 | 839.45 | 02-JAN-20:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:MECH_FLR_1 | 12.47 | 176.73 | 02-JAN-02:10 | 839.45 | 02-JAN-20:10 |
InteriorEquipment:Electricity:Zone:STORAGE_FLR_1 | 3.60 | 50.98 | 02-JAN-02:10 | 242.16 | 02-JAN-20:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:STORAGE_FLR_1 | 3.60 | 50.98 | 02-JAN-02:10 | 242.16 | 02-JAN-20:10 |
InteriorEquipment:Electricity:Zone:LAUNDRY_FLR_1 | 67.94 | 962.69 | 02-JAN-02:10 | 4572.80 | 02-JAN-20:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:LAUNDRY_FLR_1 | 67.94 | 962.69 | 02-JAN-02:10 | 4572.80 | 02-JAN-20:10 |
InteriorEquipment:Electricity:Zone:CAFE_FLR_1 | 14.34 | 203.22 | 02-JAN-02:10 | 965.27 | 02-JAN-20:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:CAFE_FLR_1 | 14.34 | 203.22 | 02-JAN-02:10 | 965.27 | 02-JAN-20:10 |
InteriorEquipment:Electricity:Zone:LOBBY_FLR_1 | 149.00 | 2111.41 | 02-JAN-02:10 | 10029.21 | 02-JAN-20:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:LOBBY_FLR_1 | 149.00 | 2111.41 | 02-JAN-02:10 | 10029.21 | 02-JAN-20:10 |
InteriorEquipment:Electricity:Zone:ROOM_1_FLR_3 | 12.29 | 210.72 | 01-JAN-00:10 | 948.23 | 01-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_1_FLR_3 | 12.29 | 210.72 | 01-JAN-00:10 | 948.23 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ROOM_2_FLR_3 | 12.29 | 210.69 | 01-JAN-00:10 | 948.12 | 01-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_2_FLR_3 | 12.29 | 210.69 | 01-JAN-00:10 | 948.12 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ROOM_3_MULT19_FLR_3 | 228.75 | 3921.46 | 01-JAN-00:10 | 17646.57 | 01-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_3_MULT19_FLR_3 | 228.75 | 3921.46 | 01-JAN-00:10 | 17646.57 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ROOM_4_MULT19_FLR_3 | 228.82 | 3922.53 | 01-JAN-00:10 | 17651.40 | 01-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_4_MULT19_FLR_3 | 228.82 | 3922.53 | 01-JAN-00:10 | 17651.40 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ROOM_5_FLR_3 | 12.29 | 210.72 | 01-JAN-00:10 | 948.23 | 01-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_5_FLR_3 | 12.29 | 210.72 | 01-JAN-00:10 | 948.23 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ROOM_6_FLR_3 | 12.29 | 210.69 | 01-JAN-00:10 | 948.12 | 01-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_6_FLR_3 | 12.29 | 210.69 | 01-JAN-00:10 | 948.12 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ROOM_1_FLR_6 | 3.07 | 52.68 | 01-JAN-00:10 | 237.06 | 01-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_1_FLR_6 | 3.07 | 52.68 | 01-JAN-00:10 | 237.06 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ROOM_2_FLR_6 | 3.07 | 52.67 | 01-JAN-00:10 | 237.03 | 01-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_2_FLR_6 | 3.07 | 52.67 | 01-JAN-00:10 | 237.03 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ROOM_3_MULT9_FLR_6 | 27.10 | 464.51 | 01-JAN-00:10 | 2090.30 | 01-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:ROOM_3_MULT9_FLR_6 | 27.10 | 464.51 | 01-JAN-00:10 | 2090.30 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:BANQUET_FLR_6 | 175.86 | 2249.30 | 01-JAN-00:10 | 6747.90 | 01-JAN-07:10 |
Cooking:InteriorEquipment:Electricity | 762.04 | 9746.88 | 01-JAN-00:10 | 29240.64 | 01-JAN-07:10 |
Cooking:InteriorEquipment:Electricity:Zone:BANQUET_FLR_6 | 175.86 | 2249.30 | 01-JAN-00:10 | 6747.90 | 01-JAN-07:10 |
Cooking:InteriorEquipment:Electricity:SpaceType:GENERAL | 762.04 | 9746.88 | 01-JAN-00:10 | 29240.64 | 01-JAN-07:10 |
InteriorEquipment:Electricity:Zone:DINING_FLR_6 | 175.86 | 2249.30 | 01-JAN-00:10 | 6747.90 | 01-JAN-07:10 |
Cooking:InteriorEquipment:Electricity:Zone:DINING_FLR_6 | 175.86 | 2249.30 | 01-JAN-00:10 | 6747.90 | 01-JAN-07:10 |
InteriorEquipment:Electricity:Zone:KITCHEN_FLR_6 | 440.03 | 6190.03 | 01-JAN-00:10 | 16686.59 | 01-JAN-07:10 |
Cooking:InteriorEquipment:Electricity:Zone:KITCHEN_FLR_6 | 410.33 | 5248.28 | 01-JAN-00:10 | 15744.84 | 01-JAN-07:10 |
ReachInFreezer:InteriorEquipment:Electricity | 16.27 | 515.92 | 01-JAN-00:10 | 515.92 | 01-JAN-00:10 |
ReachInFreezer:InteriorEquipment:Electricity:Zone:KITCHEN_FLR_6 | 16.27 | 515.92 | 01-JAN-00:10 | 515.92 | 01-JAN-00:10 |
ReachInFreezer:InteriorEquipment:Electricity:SpaceType:GENERAL | 16.27 | 515.92 | 01-JAN-00:10 | 515.92 | 01-JAN-00:10 |
ReachInRefrigerator:InteriorEquipment:Electricity | 13.43 | 425.83 | 01-JAN-00:10 | 425.83 | 01-JAN-00:10 |
ReachInRefrigerator:InteriorEquipment:Electricity:Zone:KITCHEN_FLR_6 | 13.43 | 425.83 | 01-JAN-00:10 | 425.83 | 01-JAN-00:10 |
ReachInRefrigerator:InteriorEquipment:Electricity:SpaceType:GENERAL | 13.43 | 425.83 | 01-JAN-00:10 | 425.83 | 01-JAN-00:10 |
Refrigeration:Electricity | 74.75 | 1225.93 | 11-FEB-23:30 | 3642.68 | 05-SEP-07:00 |
Refrigeration:Electricity:Zone:KITCHEN_FLR_6 | 18.27 | 261.51 | 02-JAN-11:30 | 2271.91 | 01-JAN-11:10 |
General:Refrigeration:Electricity | 18.27 | 261.51 | 02-JAN-11:30 | 2271.91 | 01-JAN-11:10 |
General:Refrigeration:Electricity:Zone:KITCHEN_FLR_6 | 18.27 | 261.51 | 02-JAN-11:30 | 2271.91 | 01-JAN-11:10 |
Electricity:Plant | 3037.87 | 2832.60 | 25-FEB-01:10 | 321268.51 | 08-JUL-15:20 |
LowTempRefrigeration:Refrigeration:Electricity | 22.44 | 0.00 | 01-JAN-11:10 | 1906.06 | 14-MAY-10:40 |
MedTempRefrigeration:Refrigeration:Electricity | 34.04 | 935.80 | 20-MAR-01:50 | 1200.61 | 22-APR-13:10 |
Fans:Electricity | 1813.98 | 52382.04 | 12-MAR-06:00 | 76570.31 | 19-AUG-15:20 |
Fans:Electricity:Zone:ROOM_1_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Ventilation (simple):Fans:Electricity:Zone:ROOM_1_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Fans:Electricity:Zone:ROOM_2_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Ventilation (simple):Fans:Electricity:Zone:ROOM_2_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Fans:Electricity:Zone:ROOM_3_MULT19_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Ventilation (simple):Fans:Electricity:Zone:ROOM_3_MULT19_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Fans:Electricity:Zone:ROOM_4_MULT19_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Ventilation (simple):Fans:Electricity:Zone:ROOM_4_MULT19_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Fans:Electricity:Zone:ROOM_5_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Ventilation (simple):Fans:Electricity:Zone:ROOM_5_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Fans:Electricity:Zone:ROOM_6_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Ventilation (simple):Fans:Electricity:Zone:ROOM_6_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Fans:Electricity:Zone:ROOM_1_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Ventilation (simple):Fans:Electricity:Zone:ROOM_1_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Fans:Electricity:Zone:ROOM_2_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Ventilation (simple):Fans:Electricity:Zone:ROOM_2_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Fans:Electricity:Zone:ROOM_3_MULT9_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Ventilation (simple):Fans:Electricity:Zone:ROOM_3_MULT9_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Electricity:HVAC | 2266.67 | 53259.60 | 12-MAR-06:00 | 95241.42 | 07-JUL-18:30 |
ExteriorEquipment:Electricity | 679.68 | 10574.27 | 02-JAN-02:20 | 40537.60 | 02-JAN-07:20 |
Transformer:ExteriorEquipment:Electricity | 32.92 | 556.27 | 02-JAN-02:20 | 1912.91 | 02-JAN-21:10 |
ElectricityPurchased:Facility | 9157.43 | 132346.64 | 27-NOV-02:50 | 598806.25 | 02-AUG-19:40 |
ElectricityPurchased:Plant | 9157.43 | 132346.64 | 27-NOV-02:50 | 598806.25 | 02-AUG-19:40 |
Cogeneration:ElectricityPurchased | 9157.43 | 132346.64 | 27-NOV-02:50 | 598806.25 | 02-AUG-19:40 |
General:Cogeneration:ElectricityPurchased | 9157.43 | 132346.64 | 27-NOV-02:50 | 598806.25 | 02-AUG-19:40 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 9157.43 | 132346.64 | 27-NOV-02:50 | 598806.25 | 02-AUG-19:40 |
ElectricityNet:Plant | 9157.43 | 132346.64 | 27-NOV-02:50 | 598806.25 | 02-AUG-19:40 |
Cogeneration:ElectricityNet | 9157.43 | 132346.64 | 27-NOV-02:50 | 598806.25 | 02-AUG-19:40 |
General:Cogeneration:ElectricityNet | 9157.43 | 132346.64 | 27-NOV-02:50 | 598806.25 | 02-AUG-19:40 |
General:Fans:Electricity | 1813.98 | 52382.04 | 12-MAR-06:00 | 76570.31 | 19-AUG-15:20 |
ExteriorLights:Electricity | 262.45 | 0.00 | 01-JAN-07:50 | 16690.39 | 01-JAN-00:10 |
General:ExteriorLights:Electricity | 262.45 | 0.00 | 01-JAN-07:50 | 16690.39 | 01-JAN-00:10 |
ElevatorLift:ExteriorEquipment:Electricity | 616.11 | 9046.01 | 01-JAN-00:10 | 37691.69 | 01-JAN-07:10 |
ElevatorLightsFan:ExteriorEquipment:Electricity | 30.65 | 972.00 | 01-JAN-00:10 | 972.00 | 01-JAN-00:10 |
HeatRecovery:Electricity | 419.77 | 0.00 | 19-JAN-10:20 | 17414.08 | 01-JAN-00:10 |
General:HeatRecovery:Electricity | 419.77 | 0.00 | 19-JAN-10:20 | 17414.08 | 01-JAN-00:10 |
WaterSystems:Electricity | 90.78 | 1087.03 | 29-JUN-00:30 | 4739.43 | 02-JAN-07:10 |
Water Heater:WaterSystems:Electricity | 90.78 | 1087.03 | 29-JUN-00:30 | 4739.43 | 02-JAN-07:10 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Boiler Parasitic:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 2593.30 | 0.00 | 01-JAN-03:30 | 302320.72 | 08-JUL-15:20 |
General:Cooling:Electricity | 2593.30 | 0.00 | 01-JAN-03:30 | 302320.72 | 08-JUL-15:20 |
Pumps:Electricity | 297.31 | 172.32 | 20-OCT-08:00 | 15178.63 | 08-JUL-10:40 |
General:Pumps:Electricity | 297.31 | 172.32 | 20-OCT-08:00 | 15178.63 | 08-JUL-10:40 |
WIRED_LTG_ELECTRICITY | 41.33 | 0.00 | 01-JAN-00:10 | 3276.83 | 02-JAN-20:20 |
Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
NaturalGas:Facility | 6043.55 | 41799.29 | 21-JUL-23:10 | 592977.58 | 07-JAN-17:10 |
NaturalGas:Building | 1788.84 | 13361.90 | 02-JAN-02:10 | 104248.32 | 02-JAN-18:10 |
NaturalGas:Zone:LAUNDRY_FLR_1 | 590.20 | 8363.49 | 02-JAN-02:10 | 39726.58 | 02-JAN-20:10 |
NaturalGas:SpaceType:GENERAL | 1788.84 | 13361.90 | 02-JAN-02:10 | 104248.32 | 02-JAN-18:10 |
InteriorEquipment:NaturalGas | 1788.84 | 13361.90 | 02-JAN-02:10 | 104248.32 | 02-JAN-18:10 |
InteriorEquipment:NaturalGas:Zone:LAUNDRY_FLR_1 | 590.20 | 8363.49 | 02-JAN-02:10 | 39726.58 | 02-JAN-20:10 |
InteriorEquipment:NaturalGas:SpaceType:GENERAL | 1788.84 | 13361.90 | 02-JAN-02:10 | 104248.32 | 02-JAN-18:10 |
Laundry:InteriorEquipment:NaturalGas | 590.20 | 8363.49 | 02-JAN-02:10 | 39726.58 | 02-JAN-20:10 |
Laundry:InteriorEquipment:NaturalGas:Zone:LAUNDRY_FLR_1 | 590.20 | 8363.49 | 02-JAN-02:10 | 39726.58 | 02-JAN-20:10 |
Laundry:InteriorEquipment:NaturalGas:SpaceType:GENERAL | 590.20 | 8363.49 | 02-JAN-02:10 | 39726.58 | 02-JAN-20:10 |
NaturalGas:Zone:KITCHEN_FLR_6 | 1198.64 | 4998.41 | 01-JAN-00:10 | 74976.11 | 01-JAN-16:10 |
InteriorEquipment:NaturalGas:Zone:KITCHEN_FLR_6 | 1198.64 | 4998.41 | 01-JAN-00:10 | 74976.11 | 01-JAN-16:10 |
Cooking:InteriorEquipment:NaturalGas | 1198.64 | 4998.41 | 01-JAN-00:10 | 74976.11 | 01-JAN-16:10 |
Cooking:InteriorEquipment:NaturalGas:Zone:KITCHEN_FLR_6 | 1198.64 | 4998.41 | 01-JAN-00:10 | 74976.11 | 01-JAN-16:10 |
Cooking:InteriorEquipment:NaturalGas:SpaceType:GENERAL | 1198.64 | 4998.41 | 01-JAN-00:10 | 74976.11 | 01-JAN-16:10 |
NaturalGas:Plant | 4254.71 | 18723.73 | 04-AUG-05:40 | 508712.89 | 11-FEB-24:00 |
WaterSystems:NaturalGas | 2989.27 | 18467.44 | 02-JAN-16:10 | 273976.11 | 10-FEB-21:20 |
Water Heater:WaterSystems:NaturalGas | 2989.27 | 18467.44 | 02-JAN-16:10 | 273976.11 | 10-FEB-21:20 |
Heating:NaturalGas | 1265.44 | 0.00 | 29-MAR-21:10 | 345449.91 | 12-FEB-07:10 |
Boiler:Heating:NaturalGas | 1265.44 | 0.00 | 29-MAR-21:10 | 345449.91 | 12-FEB-07:10 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
PlantLoopCoolingDemand:Facility | 7921.34 | 0.00 | 01-JAN-03:30 | 876754.44 | 29-JUL-19:20 |
PlantLoopCoolingDemand:HVAC | 7921.34 | 0.00 | 01-JAN-03:30 | 876754.44 | 29-JUL-19:20 |
CoolingCoils:PlantLoopCoolingDemand | 7921.34 | 0.00 | 01-JAN-03:30 | 876754.44 | 29-JUL-19:20 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 9857.19 | 0.00 | 02-JAN-01:10 | 0.00 | 02-JAN-21:10 |
Water:Plant | 9857.19 | 0.00 | 02-JAN-01:10 | 0.00 | 02-JAN-21:10 |
WaterSystems:Water | 9857.19 | 0.00 | 02-JAN-01:10 | 0.00 | 02-JAN-21:10 |
Water Heater:WaterSystems:Water | 5742.51 | 0.00 | 02-JAN-01:10 | 0.00 | 02-JAN-19:20 |
MainsWater:Facility | 9857.19 | 0.00 | 02-JAN-01:10 | 0.00 | 02-JAN-21:10 |
MainsWater:Plant | 9857.19 | 0.00 | 02-JAN-01:10 | 0.00 | 02-JAN-21:10 |
WaterSystems:MainsWater | 9857.19 | 0.00 | 02-JAN-01:10 | 0.00 | 02-JAN-21:10 |
Water Heater:WaterSystems:MainsWater | 5742.51 | 0.00 | 02-JAN-01:10 | 0.00 | 02-JAN-19:20 |
WaterUse:WaterSystems:Water | 4114.69 | 0.00 | 02-JAN-01:10 | 0.00 | 02-JAN-07:10 |
WaterUse:WaterSystems:MainsWater | 4114.69 | 0.00 | 02-JAN-01:10 | 0.00 | 02-JAN-07:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
EnergyTransfer:Facility | 40567.45 | 225195.20 | 31-OCT-11:30 | 3806359.56 | 06-JUL-18:10 |
EnergyTransfer:Building | 6045.62 | 81968.00 | 06-JAN-11:10 | 394848.81 | 02-AUG-18:10 |
EnergyTransfer:Zone:KITCHEN_FLR_6 | 744.78 | 9529.71 | 12-FEB-04:00 | 36178.89 | 08-JUL-10:50 |
Refrigeration:EnergyTransfer | 189.56 | 3614.28 | 11-FEB-23:30 | 10378.34 | 05-SEP-07:00 |
Refrigeration:EnergyTransfer:Zone:KITCHEN_FLR_6 | 94.78 | 1807.14 | 11-FEB-23:30 | 5189.17 | 05-SEP-07:00 |
General:Refrigeration:EnergyTransfer | 94.78 | 1807.14 | 11-FEB-23:30 | 5189.17 | 05-SEP-07:00 |
General:Refrigeration:EnergyTransfer:Zone:KITCHEN_FLR_6 | 94.78 | 1807.14 | 11-FEB-23:30 | 5189.17 | 05-SEP-07:00 |
EnergyTransfer:Plant | 20557.39 | 36415.26 | 07-DEC-23:20 | 2067679.80 | 06-JUL-18:10 |
LowTempRefrigeration:Refrigeration:EnergyTransfer | 25.78 | 0.00 | 01-JAN-11:10 | 2686.44 | 01-JAN-11:40 |
MedTempRefrigeration:Refrigeration:EnergyTransfer | 69.00 | 1757.40 | 20-MAR-01:50 | 2551.83 | 22-APR-13:10 |
EnergyTransfer:Zone:BASEMENT | 450.54 | 4527.77 | 08-APR-13:20 | 22846.96 | 10-AUG-18:10 |
Heating:EnergyTransfer | 112.02 | 0.00 | 01-JAN-08:10 | 98591.74 | 07-JAN-16:10 |
Heating:EnergyTransfer:Zone:BASEMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer | 112.02 | 0.00 | 01-JAN-08:10 | 98591.74 | 07-JAN-16:10 |
General:Heating:EnergyTransfer:Zone:BASEMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer | 5838.82 | 62305.28 | 08-JAN-16:00 | 391045.80 | 02-AUG-18:10 |
Cooling:EnergyTransfer:Zone:BASEMENT | 450.54 | 4527.77 | 08-APR-13:20 | 22846.96 | 10-AUG-18:10 |
General:Cooling:EnergyTransfer | 5838.82 | 62305.28 | 08-JAN-16:00 | 391045.80 | 02-AUG-18:10 |
General:Cooling:EnergyTransfer:Zone:BASEMENT | 450.54 | 4527.77 | 08-APR-13:20 | 22846.96 | 10-AUG-18:10 |
EnergyTransfer:Zone:RETAIL_1_FLR_1 | 44.85 | 0.04 | 10-FEB-01:20 | 3307.77 | 08-JUL-17:30 |
Heating:EnergyTransfer:Zone:RETAIL_1_FLR_1 | 1.72 | 0.00 | 01-JAN-00:50 | 1592.05 | 12-FEB-07:00 |
General:Heating:EnergyTransfer:Zone:RETAIL_1_FLR_1 | 1.72 | 0.00 | 01-JAN-00:50 | 1592.05 | 12-FEB-07:00 |
Cooling:EnergyTransfer:Zone:RETAIL_1_FLR_1 | 43.14 | 0.00 | 01-JAN-00:10 | 3307.77 | 08-JUL-17:30 |
General:Cooling:EnergyTransfer:Zone:RETAIL_1_FLR_1 | 43.14 | 0.00 | 01-JAN-00:10 | 3307.77 | 08-JUL-17:30 |
EnergyTransfer:Zone:RETAIL_2_FLR_1 | 41.90 | 63.10 | 08-JAN-14:00 | 2347.07 | 02-AUG-18:10 |
Heating:EnergyTransfer:Zone:RETAIL_2_FLR_1 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer:Zone:RETAIL_2_FLR_1 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:RETAIL_2_FLR_1 | 41.90 | 63.10 | 08-JAN-14:00 | 2347.07 | 02-AUG-18:10 |
General:Cooling:EnergyTransfer:Zone:RETAIL_2_FLR_1 | 41.90 | 63.10 | 08-JAN-14:00 | 2347.07 | 02-AUG-18:10 |
EnergyTransfer:Zone:MECH_FLR_1 | 34.50 | 0.01 | 24-JAN-06:30 | 2486.73 | 08-JUL-18:10 |
Heating:EnergyTransfer:Zone:MECH_FLR_1 | 0.59 | 0.00 | 01-JAN-00:10 | 596.29 | 12-FEB-06:00 |
General:Heating:EnergyTransfer:Zone:MECH_FLR_1 | 0.59 | 0.00 | 01-JAN-00:10 | 596.29 | 12-FEB-06:00 |
Cooling:EnergyTransfer:Zone:MECH_FLR_1 | 33.91 | 0.00 | 02-JAN-04:00 | 2486.73 | 08-JUL-18:10 |
General:Cooling:EnergyTransfer:Zone:MECH_FLR_1 | 33.91 | 0.00 | 02-JAN-04:00 | 2486.73 | 08-JUL-18:10 |
EnergyTransfer:Zone:STORAGE_FLR_1 | 15.26 | 0.00 | 25-NOV-01:00 | 1224.47 | 08-JUL-18:10 |
Heating:EnergyTransfer:Zone:STORAGE_FLR_1 | 0.92 | 0.00 | 01-JAN-00:10 | 460.44 | 12-FEB-07:00 |
General:Heating:EnergyTransfer:Zone:STORAGE_FLR_1 | 0.92 | 0.00 | 01-JAN-00:10 | 460.44 | 12-FEB-07:00 |
Cooling:EnergyTransfer:Zone:STORAGE_FLR_1 | 14.34 | 0.00 | 01-JAN-15:30 | 1224.47 | 08-JUL-18:10 |
General:Cooling:EnergyTransfer:Zone:STORAGE_FLR_1 | 14.34 | 0.00 | 01-JAN-15:30 | 1224.47 | 08-JUL-18:10 |
EnergyTransfer:Zone:LAUNDRY_FLR_1 | 606.88 | 8208.73 | 13-FEB-05:00 | 38164.53 | 02-AUG-20:00 |
Heating:EnergyTransfer:Zone:LAUNDRY_FLR_1 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer:Zone:LAUNDRY_FLR_1 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:LAUNDRY_FLR_1 | 606.88 | 8208.73 | 13-FEB-05:00 | 38164.53 | 02-AUG-20:00 |
General:Cooling:EnergyTransfer:Zone:LAUNDRY_FLR_1 | 606.88 | 8208.73 | 13-FEB-05:00 | 38164.53 | 02-AUG-20:00 |
EnergyTransfer:Zone:CAFE_FLR_1 | 266.63 | 3.20 | 06-JAN-12:10 | 13886.03 | 08-JUL-17:40 |
Heating:EnergyTransfer:Zone:CAFE_FLR_1 | 0.01 | 0.00 | 01-JAN-00:10 | 962.97 | 09-JAN-09:20 |
General:Heating:EnergyTransfer:Zone:CAFE_FLR_1 | 0.01 | 0.00 | 01-JAN-00:10 | 962.97 | 09-JAN-09:20 |
Cooling:EnergyTransfer:Zone:CAFE_FLR_1 | 266.62 | 0.00 | 06-JAN-09:10 | 13886.03 | 08-JUL-17:40 |
General:Cooling:EnergyTransfer:Zone:CAFE_FLR_1 | 266.62 | 0.00 | 06-JAN-09:10 | 13886.03 | 08-JUL-17:40 |
EnergyTransfer:Zone:LOBBY_FLR_1 | 922.68 | 4484.78 | 08-JAN-16:00 | 45613.22 | 08-JUL-18:10 |
Heating:EnergyTransfer:Zone:LOBBY_FLR_1 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer:Zone:LOBBY_FLR_1 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:LOBBY_FLR_1 | 922.68 | 4484.78 | 08-JAN-16:00 | 45613.22 | 08-JUL-18:10 |
General:Cooling:EnergyTransfer:Zone:LOBBY_FLR_1 | 922.68 | 4484.78 | 08-JAN-16:00 | 45613.22 | 08-JUL-18:10 |
EnergyTransfer:Zone:ROOM_1_FLR_3 | 70.94 | 0.07 | 03-MAR-10:30 | 11005.17 | 21-JUL-18:10 |
Heating:EnergyTransfer:Zone:ROOM_1_FLR_3 | 11.83 | 0.00 | 01-JAN-08:10 | 6432.08 | 12-FEB-06:00 |
General:Heating:EnergyTransfer:Zone:ROOM_1_FLR_3 | 11.83 | 0.00 | 01-JAN-08:10 | 6432.08 | 12-FEB-06:00 |
Cooling:EnergyTransfer:Zone:ROOM_1_FLR_3 | 59.11 | 0.00 | 01-JAN-00:10 | 11005.17 | 21-JUL-18:10 |
General:Cooling:EnergyTransfer:Zone:ROOM_1_FLR_3 | 59.11 | 0.00 | 01-JAN-00:10 | 11005.17 | 21-JUL-18:10 |
EnergyTransfer:Zone:ROOM_2_FLR_3 | 68.79 | 0.13 | 08-OCT-03:50 | 11042.53 | 21-JUL-18:10 |
Heating:EnergyTransfer:Zone:ROOM_2_FLR_3 | 15.35 | 0.00 | 01-JAN-08:10 | 6979.54 | 12-FEB-09:20 |
General:Heating:EnergyTransfer:Zone:ROOM_2_FLR_3 | 15.35 | 0.00 | 01-JAN-08:10 | 6979.54 | 12-FEB-09:20 |
Cooling:EnergyTransfer:Zone:ROOM_2_FLR_3 | 53.44 | 0.00 | 01-JAN-00:10 | 11042.53 | 21-JUL-18:10 |
General:Cooling:EnergyTransfer:Zone:ROOM_2_FLR_3 | 53.44 | 0.00 | 01-JAN-00:10 | 11042.53 | 21-JUL-18:10 |
EnergyTransfer:Zone:ROOM_3_MULT19_FLR_3 | 520.19 | 18.22 | 03-JAN-24:00 | 50249.64 | 10-OCT-13:30 |
Heating:EnergyTransfer:Zone:ROOM_3_MULT19_FLR_3 | 3.04 | 0.00 | 01-JAN-00:10 | 20260.82 | 12-FEB-06:00 |
General:Heating:EnergyTransfer:Zone:ROOM_3_MULT19_FLR_3 | 3.04 | 0.00 | 01-JAN-00:10 | 20260.82 | 12-FEB-06:00 |
Cooling:EnergyTransfer:Zone:ROOM_3_MULT19_FLR_3 | 517.14 | 0.00 | 03-JAN-16:30 | 50249.64 | 10-OCT-13:30 |
General:Cooling:EnergyTransfer:Zone:ROOM_3_MULT19_FLR_3 | 517.14 | 0.00 | 03-JAN-16:30 | 50249.64 | 10-OCT-13:30 |
EnergyTransfer:Zone:ROOM_4_MULT19_FLR_3 | 594.99 | 0.18 | 01-DEC-08:00 | 76649.20 | 16-JUL-18:30 |
Heating:EnergyTransfer:Zone:ROOM_4_MULT19_FLR_3 | 24.12 | 0.00 | 01-JAN-00:10 | 43094.82 | 07-JAN-16:10 |
General:Heating:EnergyTransfer:Zone:ROOM_4_MULT19_FLR_3 | 24.12 | 0.00 | 01-JAN-00:10 | 43094.82 | 07-JAN-16:10 |
Cooling:EnergyTransfer:Zone:ROOM_4_MULT19_FLR_3 | 570.86 | 0.00 | 02-JAN-03:00 | 76649.20 | 16-JUL-18:30 |
General:Cooling:EnergyTransfer:Zone:ROOM_4_MULT19_FLR_3 | 570.86 | 0.00 | 02-JAN-03:00 | 76649.20 | 16-JUL-18:30 |
EnergyTransfer:Zone:ROOM_5_FLR_3 | 70.85 | 0.02 | 23-NOV-17:20 | 9574.20 | 08-JUL-15:10 |
Heating:EnergyTransfer:Zone:ROOM_5_FLR_3 | 11.74 | 0.00 | 01-JAN-08:10 | 6464.45 | 12-FEB-06:00 |
General:Heating:EnergyTransfer:Zone:ROOM_5_FLR_3 | 11.74 | 0.00 | 01-JAN-08:10 | 6464.45 | 12-FEB-06:00 |
Cooling:EnergyTransfer:Zone:ROOM_5_FLR_3 | 59.11 | 0.00 | 01-JAN-00:10 | 9574.20 | 08-JUL-15:10 |
General:Cooling:EnergyTransfer:Zone:ROOM_5_FLR_3 | 59.11 | 0.00 | 01-JAN-00:10 | 9574.20 | 08-JUL-15:10 |
EnergyTransfer:Zone:ROOM_6_FLR_3 | 68.49 | 0.03 | 29-NOV-21:30 | 9609.30 | 07-JUL-08:10 |
Heating:EnergyTransfer:Zone:ROOM_6_FLR_3 | 15.16 | 0.00 | 01-JAN-08:10 | 6656.16 | 12-FEB-06:00 |
General:Heating:EnergyTransfer:Zone:ROOM_6_FLR_3 | 15.16 | 0.00 | 01-JAN-08:10 | 6656.16 | 12-FEB-06:00 |
Cooling:EnergyTransfer:Zone:ROOM_6_FLR_3 | 53.33 | 0.00 | 01-JAN-00:10 | 9609.30 | 07-JUL-08:10 |
General:Cooling:EnergyTransfer:Zone:ROOM_6_FLR_3 | 53.33 | 0.00 | 01-JAN-00:10 | 9609.30 | 07-JUL-08:10 |
EnergyTransfer:Zone:CORRIDOR_FLR_3 | 203.66 | 0.69 | 11-FEB-09:50 | 12462.95 | 19-AUG-10:40 |
Heating:EnergyTransfer:Zone:CORRIDOR_FLR_3 | 1.72 | 0.00 | 01-JAN-00:10 | 3834.59 | 07-JAN-17:00 |
General:Heating:EnergyTransfer:Zone:CORRIDOR_FLR_3 | 1.72 | 0.00 | 01-JAN-00:10 | 3834.59 | 07-JAN-17:00 |
Cooling:EnergyTransfer:Zone:CORRIDOR_FLR_3 | 201.94 | 0.00 | 01-JAN-16:00 | 12462.95 | 19-AUG-10:40 |
General:Cooling:EnergyTransfer:Zone:CORRIDOR_FLR_3 | 201.94 | 0.00 | 01-JAN-16:00 | 12462.95 | 19-AUG-10:40 |
EnergyTransfer:Zone:ROOM_1_FLR_6 | 20.75 | 0.04 | 19-NOV-10:00 | 3133.25 | 18-AUG-15:20 |
Heating:EnergyTransfer:Zone:ROOM_1_FLR_6 | 4.65 | 0.00 | 01-JAN-08:10 | 2083.24 | 12-FEB-06:00 |
General:Heating:EnergyTransfer:Zone:ROOM_1_FLR_6 | 4.65 | 0.00 | 01-JAN-08:10 | 2083.24 | 12-FEB-06:00 |
Cooling:EnergyTransfer:Zone:ROOM_1_FLR_6 | 16.11 | 0.00 | 01-JAN-00:10 | 3133.25 | 18-AUG-15:20 |
General:Cooling:EnergyTransfer:Zone:ROOM_1_FLR_6 | 16.11 | 0.00 | 01-JAN-00:10 | 3133.25 | 18-AUG-15:20 |
EnergyTransfer:Zone:ROOM_2_FLR_6 | 20.45 | 0.02 | 05-NOV-02:40 | 3078.12 | 08-JUL-15:10 |
Heating:EnergyTransfer:Zone:ROOM_2_FLR_6 | 5.80 | 0.00 | 01-JAN-08:10 | 2262.27 | 12-FEB-09:20 |
General:Heating:EnergyTransfer:Zone:ROOM_2_FLR_6 | 5.80 | 0.00 | 01-JAN-08:10 | 2262.27 | 12-FEB-09:20 |
Cooling:EnergyTransfer:Zone:ROOM_2_FLR_6 | 14.65 | 0.00 | 01-JAN-00:10 | 3078.12 | 08-JUL-15:10 |
General:Cooling:EnergyTransfer:Zone:ROOM_2_FLR_6 | 14.65 | 0.00 | 01-JAN-00:10 | 3078.12 | 08-JUL-15:10 |
EnergyTransfer:Zone:ROOM_3_MULT9_FLR_6 | 110.17 | 0.07 | 21-FEB-03:00 | 15345.02 | 25-SEP-15:10 |
Heating:EnergyTransfer:Zone:ROOM_3_MULT9_FLR_6 | 10.53 | 0.00 | 01-JAN-08:10 | 9329.48 | 07-JAN-16:20 |
General:Heating:EnergyTransfer:Zone:ROOM_3_MULT9_FLR_6 | 10.53 | 0.00 | 01-JAN-08:10 | 9329.48 | 07-JAN-16:20 |
Cooling:EnergyTransfer:Zone:ROOM_3_MULT9_FLR_6 | 99.64 | 0.00 | 01-JAN-00:10 | 15345.02 | 25-SEP-15:10 |
General:Cooling:EnergyTransfer:Zone:ROOM_3_MULT9_FLR_6 | 99.64 | 0.00 | 01-JAN-00:10 | 15345.02 | 25-SEP-15:10 |
EnergyTransfer:Zone:BANQUET_FLR_6 | 516.01 | 6206.45 | 03-FEB-09:30 | 23673.63 | 08-JUL-17:40 |
Heating:EnergyTransfer:Zone:BANQUET_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer:Zone:BANQUET_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:BANQUET_FLR_6 | 516.01 | 6206.45 | 03-FEB-09:30 | 23673.63 | 08-JUL-17:40 |
General:Cooling:EnergyTransfer:Zone:BANQUET_FLR_6 | 516.01 | 6206.45 | 03-FEB-09:30 | 23673.63 | 08-JUL-17:40 |
EnergyTransfer:Zone:DINING_FLR_6 | 552.72 | 7369.20 | 03-FEB-09:20 | 24999.81 | 08-JUL-17:40 |
Heating:EnergyTransfer:Zone:DINING_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer:Zone:DINING_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:DINING_FLR_6 | 552.72 | 7369.20 | 03-FEB-09:20 | 24999.81 | 08-JUL-17:40 |
General:Cooling:EnergyTransfer:Zone:DINING_FLR_6 | 552.72 | 7369.20 | 03-FEB-09:20 | 24999.81 | 08-JUL-17:40 |
Heating:EnergyTransfer:Zone:KITCHEN_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer:Zone:KITCHEN_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:KITCHEN_FLR_6 | 650.00 | 7360.53 | 12-FEB-04:00 | 31122.70 | 08-JUL-10:50 |
General:Cooling:EnergyTransfer:Zone:KITCHEN_FLR_6 | 650.00 | 7360.53 | 12-FEB-04:00 | 31122.70 | 08-JUL-10:50 |
EnergyTransfer:Zone:CORRIDOR_FLR_6 | 99.60 | 0.13 | 02-FEB-11:30 | 7622.39 | 08-JUL-17:20 |
Heating:EnergyTransfer:Zone:CORRIDOR_FLR_6 | 4.86 | 0.00 | 01-JAN-00:30 | 3470.78 | 12-FEB-07:10 |
General:Heating:EnergyTransfer:Zone:CORRIDOR_FLR_6 | 4.86 | 0.00 | 01-JAN-00:30 | 3470.78 | 12-FEB-07:10 |
Cooling:EnergyTransfer:Zone:CORRIDOR_FLR_6 | 94.73 | 0.00 | 01-JAN-00:10 | 7622.39 | 08-JUL-17:20 |
General:Cooling:EnergyTransfer:Zone:CORRIDOR_FLR_6 | 94.73 | 0.00 | 01-JAN-00:10 | 7622.39 | 08-JUL-17:20 |
PlantLoopHeatingDemand:Facility | 1527.15 | 10618.34 | 20-AUG-00:10 | 312542.00 | 12-FEB-07:10 |
PlantLoopHeatingDemand:Plant | 671.59 | 7488.42 | 04-AUG-01:40 | 51955.12 | 01-FEB-08:00 |
WaterSystems:PlantLoopHeatingDemand | 671.59 | 7488.42 | 04-AUG-01:40 | 51955.12 | 01-FEB-08:00 |
General:WaterSystems:PlantLoopHeatingDemand | 671.59 | 7488.42 | 04-AUG-01:40 | 51955.12 | 01-FEB-08:00 |
EnergyTransfer:HVAC | 13964.43 | 23653.93 | 02-NOV-07:40 | 1399641.12 | 19-AUG-17:00 |
HeatingCoils:EnergyTransfer | 855.56 | 0.00 | 29-MAR-21:10 | 272434.87 | 12-FEB-07:10 |
PlantLoopHeatingDemand:HVAC | 855.56 | 0.00 | 29-MAR-21:10 | 272434.87 | 12-FEB-07:10 |
HeatingCoils:PlantLoopHeatingDemand | 855.56 | 0.00 | 29-MAR-21:10 | 272434.87 | 12-FEB-07:10 |
CoolingCoils:EnergyTransfer | 7921.34 | 0.00 | 01-JAN-03:30 | 876754.44 | 29-JUL-19:20 |
HeatRecoveryForHeating:EnergyTransfer | 2572.53 | 0.00 | 19-JAN-10:20 | 721267.17 | 12-FEB-07:00 |
HeatRecoveryForCooling:EnergyTransfer | 2615.00 | 0.00 | 01-JAN-00:10 | 536528.00 | 07-JUL-12:00 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:EnergyTransfer | 671.59 | 7488.42 | 04-AUG-01:40 | 51955.12 | 01-FEB-08:00 |
WaterUse:WaterSystems:EnergyTransfer | 671.59 | 7488.42 | 04-AUG-01:40 | 51955.12 | 01-FEB-08:00 |
Boilers:EnergyTransfer | 848.26 | 0.00 | 29-MAR-21:10 | 271426.31 | 12-FEB-07:10 |
Chillers:EnergyTransfer | 8174.73 | 0.00 | 01-JAN-03:30 | 886415.82 | 29-JUL-19:20 |
HeatRejection:EnergyTransfer | 10768.03 | 0.00 | 01-JAN-03:30 | 1162916.32 | 06-JUL-18:10 |
General:HeatRejection:EnergyTransfer | 10768.03 | 0.00 | 01-JAN-03:30 | 1162916.32 | 06-JUL-18:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
BASEMENT | 0.000 | 0.000 | 0.000 | -450.542 | 0.000 | 0.000 | 157.448 | 165.288 | 150.255 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -22.449 |
RETAIL_1_FLR_1 | 0.000 | 0.000 | 1.716 | -43.138 | 0.000 | 0.000 | 16.124 | 8.404 | 10.186 | 19.740 | 0.000 | 1.094 | 0.001 | 0.000 | -7.989 | 0.000 | -4.227 | -1.910 |
RETAIL_2_FLR_1 | 0.000 | 0.000 | 0.000 | -41.905 | 0.000 | 0.000 | 18.582 | 9.732 | 11.795 | 0.000 | 0.000 | 0.422 | 3.012 | 0.000 | 0.000 | 0.000 | -1.637 | -0.000 |
MECH_FLR_1 | 0.000 | 0.000 | 0.588 | -33.910 | 0.000 | 0.000 | 3.948 | 18.192 | 12.471 | 0.000 | 0.000 | 1.015 | 1.546 | 0.000 | 0.000 | 0.000 | -3.851 | -0.000 |
STORAGE_FLR_1 | 0.000 | 0.000 | 0.918 | -14.339 | 0.000 | 0.000 | 3.042 | 3.340 | 3.598 | 0.000 | 0.000 | 0.593 | 5.067 | 0.000 | 0.000 | 0.000 | -2.219 | -0.000 |
LAUNDRY_FLR_1 | 0.000 | 0.000 | 0.000 | -606.886 | 0.000 | 0.000 | 12.210 | 4.125 | 658.131 | 0.000 | 0.000 | 1.318 | 0.000 | 0.000 | 0.000 | 0.000 | -5.481 | -63.417 |
CAFE_FLR_1 | 0.000 | 0.000 | 0.009 | -266.622 | 0.000 | 0.000 | 209.651 | 26.624 | 14.341 | 55.145 | 0.000 | 2.341 | 0.000 | 0.000 | -23.044 | 0.000 | -9.436 | -9.008 |
LOBBY_FLR_1 | 0.000 | 0.000 | 0.000 | -922.688 | 0.000 | 0.000 | 620.208 | 144.896 | 148.998 | 73.424 | 0.000 | 6.718 | 0.000 | 0.000 | -30.713 | 0.000 | -27.125 | -13.719 |
ROOM_1_FLR_3 | 14.915 | -45.627 | 0.000 | -16.570 | 0.000 | 0.000 | 9.715 | 20.410 | 12.292 | 39.335 | 0.000 | 2.296 | 0.000 | 0.000 | -19.158 | 0.000 | -10.615 | -6.993 |
ROOM_2_FLR_3 | 18.945 | -40.712 | 0.000 | -16.331 | 0.000 | 0.000 | 9.737 | 20.407 | 12.291 | 30.657 | 0.000 | 2.305 | 0.000 | 0.000 | -20.039 | 0.000 | -10.443 | -6.819 |
ROOM_3_MULT19_FLR_3 | 4.650 | -252.195 | 0.000 | -266.551 | 0.000 | 0.000 | 0.000 | 243.708 | 228.754 | 222.771 | 0.000 | 8.248 | 10.921 | 0.000 | -116.405 | 0.000 | -83.901 | -0.002 |
ROOM_4_MULT19_FLR_3 | 45.507 | -369.270 | 0.000 | -222.959 | 0.000 | 0.000 | 184.788 | 243.774 | 228.817 | 93.092 | 0.000 | 14.431 | 0.001 | 0.000 | -113.815 | 0.000 | -64.753 | -39.611 |
ROOM_5_FLR_3 | 14.806 | -45.510 | 0.000 | -16.665 | 0.000 | 0.000 | 9.706 | 20.410 | 12.292 | 39.126 | 0.000 | 2.289 | 0.000 | 0.000 | -18.502 | 0.000 | -10.677 | -7.276 |
ROOM_6_FLR_3 | 18.740 | -40.484 | 0.000 | -16.429 | 0.000 | 0.000 | 9.730 | 20.407 | 12.291 | 29.943 | 0.000 | 2.292 | 0.000 | 0.000 | -18.881 | 0.000 | -10.499 | -7.109 |
CORRIDOR_FLR_3 | 0.000 | 0.000 | 1.718 | -201.942 | 0.000 | 0.000 | 123.012 | 62.736 | 0.000 | 37.202 | 0.000 | 2.720 | 10.236 | 0.000 | -23.667 | 0.000 | -12.015 | -0.000 |
ROOM_1_FLR_6 | 5.526 | -12.860 | 0.000 | -4.125 | 0.000 | 0.000 | 2.431 | 5.102 | 3.073 | 9.708 | 0.000 | 0.571 | 0.000 | 0.000 | -4.760 | 0.000 | -2.687 | -1.980 |
ROOM_2_FLR_6 | 6.802 | -11.576 | 0.000 | -4.072 | 0.000 | 0.000 | 2.436 | 5.102 | 3.073 | 7.558 | 0.000 | 0.572 | 0.000 | 0.000 | -4.977 | 0.000 | -2.645 | -2.272 |
ROOM_3_MULT9_FLR_6 | 14.214 | -76.261 | 0.000 | -27.063 | 0.000 | 0.000 | 21.795 | 28.868 | 27.097 | 49.516 | 0.000 | 2.808 | 0.003 | 0.000 | -22.132 | 0.000 | -13.524 | -5.318 |
BANQUET_FLR_6 | 0.000 | 0.000 | 0.000 | -516.010 | 0.000 | 0.000 | 357.983 | 46.753 | 175.857 | 10.603 | 0.000 | 1.362 | 0.000 | 0.000 | -14.100 | 0.000 | -6.373 | -56.075 |
DINING_FLR_6 | 0.000 | 0.000 | 0.000 | -552.727 | 0.000 | 0.000 | 356.746 | 46.753 | 175.857 | 10.350 | 0.000 | 1.339 | 0.000 | 0.000 | -14.503 | 0.000 | -6.406 | -17.409 |
KITCHEN_FLR_6 | 0.000 | 0.000 | 0.000 | -649.994 | 0.000 | 0.000 | 30.493 | 12.482 | 556.656 | 18.225 | 0.000 | 0.785 | 48.323 | 0.000 | -10.612 | 0.000 | -6.359 | -0.001 |
CORRIDOR_FLR_6 | 0.000 | 0.000 | 4.865 | -94.735 | 0.000 | 0.000 | 32.937 | 16.599 | 0.000 | 17.848 | 0.000 | 1.294 | 36.927 | 0.000 | -10.441 | 0.000 | -5.293 | -0.001 |
Total Facility | 144.106 | -894.495 | 9.815 | -4986.202 | 0.000 | 0.000 | 2192.721 | 1174.112 | 2458.123 | 764.243 | 0.000 | 56.813 | 116.038 | 0.000 | -473.738 | 0.000 | -300.163 | -261.372 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BASEMENT | 11-OCT-17:10 | 0.00 | 0.00 | 0.00 | -24756.45 | 0.00 | 0.00 | 4400.84 | 9011.27 | 7452.27 | 0.00 | 0.00 | 0.00 | 3892.07 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_1_FLR_1 | 11-OCT-17:10 | 0.00 | 0.00 | 0.00 | -3480.01 | 0.00 | 0.00 | 436.86 | 458.20 | 505.18 | 730.09 | 0.00 | 49.74 | 1299.93 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_2_FLR_1 | 07-JUN-18:03 | 0.00 | 0.00 | 0.00 | -2428.97 | 0.00 | 0.00 | 725.55 | 707.46 | 752.15 | 0.00 | 0.00 | 16.06 | 227.75 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
MECH_FLR_1 | 07-JUN-18:03 | 0.00 | 0.00 | 0.00 | -2523.12 | 0.00 | 0.00 | 153.44 | 1322.39 | 795.27 | 0.00 | 0.00 | 39.17 | 212.85 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
STORAGE_FLR_1 | 08-JUL-18:10 | 0.00 | 0.00 | 0.00 | -1225.61 | 0.00 | 0.00 | 101.12 | 212.41 | 203.92 | 0.00 | 0.00 | 134.27 | 573.89 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
LAUNDRY_FLR_1 | 15-MAY-18:56 | 0.00 | 0.00 | 0.00 | -38813.66 | 0.00 | 0.00 | 441.65 | 299.88 | 41967.83 | 0.00 | 0.00 | 103.95 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -3999.66 |
CAFE_FLR_1 | 11-OCT-17:10 | 0.00 | 0.00 | 0.00 | -14836.57 | 0.00 | 0.00 | 5772.55 | 1451.48 | 711.25 | 2059.81 | 0.00 | 115.15 | 4726.33 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
LOBBY_FLR_1 | 11-OCT-17:10 | 0.00 | 0.00 | 0.00 | -47160.86 | 0.00 | 0.00 | 17454.43 | 7899.54 | 7389.94 | 2918.99 | 0.00 | 377.29 | 11120.65 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_3 | 10-JUN-15:01 | 0.00 | -12746.78 | 0.00 | -712.87 | 0.00 | 0.00 | 130.71 | 518.40 | 305.54 | 6056.31 | 0.00 | 319.59 | 6129.10 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_3 | 10-JUN-15:01 | 0.00 | -12606.93 | 0.00 | -712.71 | 0.00 | 0.00 | 130.71 | 518.34 | 305.51 | 5954.53 | 0.00 | 319.61 | 6090.93 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ROOM_3_MULT19_FLR_3 | 10-OCT-13:30 | 0.00 | -39803.07 | 0.00 | -10453.56 | 0.00 | 0.00 | 0.00 | 5252.20 | 5097.90 | 50508.55 | 0.00 | 1351.91 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -11953.94 |
ROOM_4_MULT19_FLR_3 | 10-JUN-15:01 | 0.00 | -85489.54 | 0.00 | -9852.42 | 0.00 | 0.00 | 2483.66 | 6191.79 | 5687.67 | 11992.09 | 0.00 | 1648.80 | 67337.95 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ROOM_5_FLR_3 | 10-JUN-15:01 | 0.00 | -11534.79 | 0.00 | -713.37 | 0.00 | 0.00 | 130.72 | 518.40 | 305.54 | 2269.56 | 0.00 | 319.28 | 8704.66 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ROOM_6_FLR_3 | 10-JUN-15:01 | 0.00 | -11429.56 | 0.00 | -713.06 | 0.00 | 0.00 | 130.72 | 518.34 | 305.51 | 2168.20 | 0.00 | 319.39 | 8700.46 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_3 | 19-AUG-10:35 | 0.00 | 0.00 | 0.00 | -12500.73 | 0.00 | 0.00 | 1959.74 | 1425.11 | 0.00 | 5083.48 | 0.00 | 552.14 | 3480.25 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_6 | 10-JUN-15:01 | 0.00 | -3418.50 | 0.00 | -178.55 | 0.00 | 0.00 | 32.68 | 129.60 | 76.39 | 1492.05 | 0.00 | 79.02 | 1787.32 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_6 | 10-JUN-15:01 | 0.00 | -3377.39 | 0.00 | -178.52 | 0.00 | 0.00 | 32.68 | 129.58 | 76.38 | 1467.24 | 0.00 | 79.01 | 1771.02 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ROOM_3_MULT9_FLR_6 | 11-NOV-16:01 | 0.00 | -15959.09 | 0.00 | -1159.90 | 0.00 | 0.00 | 294.12 | 733.24 | 673.54 | 5368.87 | 0.00 | 0.00 | 10434.90 | 0.00 | -0.00 | 0.00 | -385.67 | 0.00 |
BANQUET_FLR_6 | 15-MAY-18:56 | 0.00 | 0.00 | 0.00 | -24190.87 | 0.00 | 0.00 | 13806.39 | 3398.57 | 6747.90 | 637.20 | 0.00 | 140.85 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -540.05 |
DINING_FLR_6 | 07-JUN-18:03 | 0.00 | 0.00 | 0.00 | -25700.21 | 0.00 | 0.00 | 14117.25 | 3398.57 | 6747.90 | 1190.72 | 0.00 | 36.07 | 209.69 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
KITCHEN_FLR_6 | 07-JUN-18:03 | 0.00 | 0.00 | 0.00 | -31802.72 | 0.00 | 0.00 | 1076.98 | 907.36 | 21959.95 | 295.33 | 0.00 | 0.00 | 7593.57 | 0.00 | -0.00 | 0.00 | -30.46 | 0.00 |
CORRIDOR_FLR_6 | 08-JUL-17:13 | 0.00 | 0.00 | 0.00 | -7635.63 | 0.00 | 0.00 | 1034.72 | 904.96 | 0.00 | 1409.19 | 0.00 | 296.92 | 3989.85 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 08-JUL-18:02 | 0.00 | -179316.59 | 0.00 | -243302.33 | 0.00 | 0.00 | 71938.02 | 82807.27 | 115371.52 | 40763.51 | 0.00 | 13207.21 | 98531.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BASEMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_1_FLR_1 | 12-FEB-07:00 | 0.00 | 0.00 | 1592.07 | 0.00 | 0.00 | 0.00 | 663.46 | 229.10 | 288.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1669.66 | 0.00 | -771.69 | -331.96 |
RETAIL_2_FLR_1 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MECH_FLR_1 | 12-FEB-06:00 | 0.00 | 0.00 | 596.29 | 0.00 | 0.00 | 0.00 | 155.03 | 330.60 | 265.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -710.98 | -636.02 |
STORAGE_FLR_1 | 12-FEB-07:00 | 0.00 | 0.00 | 460.45 | 0.00 | 0.00 | 0.00 | 120.45 | 91.03 | 101.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -416.45 | -357.44 |
LAUNDRY_FLR_1 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CAFE_FLR_1 | 09-JAN-09:10 | 0.00 | 0.00 | 980.67 | 0.00 | 0.00 | 0.00 | 2351.72 | 967.66 | 508.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2269.63 | 0.00 | -1206.63 | -1331.83 |
LOBBY_FLR_1 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_3 | 12-FEB-09:02 | 7783.51 | 279.30 | 0.00 | -279.30 | 0.00 | 0.00 | 163.33 | 879.71 | 653.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1279.31 | 0.00 | -1619.37 | -6581.09 |
ROOM_2_FLR_3 | 12-FEB-09:02 | 7850.63 | 274.43 | 0.00 | -274.43 | 0.00 | 0.00 | 163.33 | 879.61 | 653.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2903.60 | 0.00 | -1615.60 | -5027.52 |
ROOM_3_MULT19_FLR_3 | 12-FEB-06:00 | 20260.70 | 3319.07 | 0.00 | -3319.07 | 0.00 | 0.00 | 0.00 | 2063.36 | 3921.46 | 0.00 | 0.00 | 0.00 | 3934.64 | 0.00 | -21124.86 | 0.00 | -9055.31 | 0.00 |
ROOM_4_MULT19_FLR_3 | 27-JAN-16:01 | 45538.70 | 3782.59 | 0.00 | -3782.59 | 0.00 | 0.00 | 5552.30 | 5253.64 | 5099.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -6897.74 | 0.00 | -4087.72 | -50458.47 |
ROOM_5_FLR_3 | 07-JAN-19:02 | 7501.33 | 278.62 | 0.00 | -278.62 | 0.00 | 0.00 | 353.87 | 1570.91 | 516.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3052.11 | 0.00 | -1319.09 | -5571.17 |
ROOM_6_FLR_3 | 07-JAN-19:02 | 7501.72 | 277.60 | 0.00 | -277.60 | 0.00 | 0.00 | 353.87 | 1570.72 | 516.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3073.25 | 0.00 | -1318.28 | -5550.99 |
CORRIDOR_FLR_3 | 07-JAN-17:00 | 0.00 | 0.00 | 3834.48 | 0.00 | 0.00 | 0.00 | 2086.81 | 1425.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3370.78 | 0.00 | -1654.74 | -2320.88 |
ROOM_1_FLR_6 | 12-FEB-09:02 | 2301.04 | 69.51 | 0.00 | -69.51 | 0.00 | 0.00 | 40.83 | 219.93 | 163.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -323.67 | 0.00 | -405.50 | -1995.94 |
ROOM_2_FLR_6 | 12-FEB-09:13 | 2325.48 | 88.92 | 0.00 | -88.92 | 0.00 | 0.00 | 37.03 | 219.90 | 163.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -723.87 | 0.00 | -414.29 | -1607.54 |
ROOM_3_MULT9_FLR_6 | 07-JAN-16:13 | 10694.50 | 601.24 | 0.00 | -601.24 | 0.00 | 0.00 | 332.96 | 733.24 | 673.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2347.64 | 0.00 | -1515.51 | -8571.07 |
BANQUET_FLR_6 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
DINING_FLR_6 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
KITCHEN_FLR_6 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_6 | 12-FEB-07:10 | 0.00 | 0.00 | 3470.73 | 0.00 | 0.00 | 0.00 | 1328.53 | 603.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2263.13 | 0.00 | -973.72 | -2165.71 |
Total Facility | 07-JAN-16:13 | 33673.45 | 76328.52 | 9126.99 | -76328.52 | 0.00 | 0.00 | 36914.51 | 28303.36 | 78917.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -50592.99 | 0.00 | -32703.09 | -103639.72 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
VAV WITH REHEAT | 22.1929 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 22.0819 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
FLR_3_DOAS | 2.0513 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 2.0513 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
VAV WITH REHEAT | 22.0819 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 22.0819 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
FLR_3_DOAS | 2.0513 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 2.0513 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
BASEMENT | VAV WITH REHEAT | 0.000000 | 106.4990 | 0.000432 | 1978.83 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
RETAIL_1_FLR_1 | VAV WITH REHEAT | 0.000000 | 10.8290 | 0.001181 | 67.07 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
RETAIL_2_FLR_1 | VAV WITH REHEAT | 0.000000 | 12.5400 | 0.001181 | 77.67 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
MECH_FLR_1 | VAV WITH REHEAT | 0.000000 | 2.6520 | 0.000000 | 164.24 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
STORAGE_FLR_1 | VAV WITH REHEAT | 0.000000 | 2.0400 | 0.000610 | 94.76 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
LAUNDRY_FLR_1 | VAV WITH REHEAT | 0.000000 | 8.4000 | 0.000000 | 78.04 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
CAFE_FLR_1 | VAV WITH REHEAT | 0.000000 | 142.3000 | 0.003581 | 188.86 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
LOBBY_FLR_1 | VAV WITH REHEAT | 0.000000 | 422.4350 | 0.001448 | 1308.19 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_1_FLR_3 | FLR_3_DOAS | 0.000000 | 6.0000 | 0.000396 | 156.09 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_2_FLR_3 | FLR_3_DOAS | 0.000000 | 6.0000 | 0.000396 | 156.07 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_3_MULT19_FLR_3 | FLR_3_DOAS | 0.000000 | 114.0000 | 0.000449 | 1863.81 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_4_MULT19_FLR_3 | FLR_3_DOAS | 0.000000 | 114.0000 | 0.000449 | 1864.32 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_5_FLR_3 | FLR_3_DOAS | 0.000000 | 6.0000 | 0.000396 | 156.09 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_6_FLR_3 | FLR_3_DOAS | 0.000000 | 6.0000 | 0.000396 | 156.07 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
CORRIDOR_FLR_3 | VAV WITH REHEAT | 0.000000 | 83.8280 | 0.000305 | 1557.62 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_1_FLR_6 | FLR_3_DOAS | 0.000000 | 1.5000 | 0.000396 | 39.02 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_2_FLR_6 | FLR_3_DOAS | 0.000000 | 1.5000 | 0.000396 | 39.02 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_3_MULT9_FLR_6 | FLR_3_DOAS | 0.000000 | 13.5000 | 0.000449 | 220.77 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
BANQUET_FLR_6 | VAV WITH REHEAT | 0.000000 | 249.8960 | 0.003581 | 331.66 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
DINING_FLR_6 | VAV WITH REHEAT | 0.000000 | 249.8960 | 0.003581 | 331.66 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
KITCHEN_FLR_6 | VAV WITH REHEAT | 0.000000 | 22.2380 | 0.003556 | 103.30 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
CORRIDOR_FLR_6 | VAV WITH REHEAT | 0.000000 | 22.1800 | 0.000305 | 412.12 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
VAV WITH REHEAT | 0.00 | 0.001045 | 6694.0231 | 0.0000 | 0.0000 | 0.0000 | |
FLR_3_DOAS | 0.00 | 0.000441 | 4651.2638 | 0.0000 | 0.0000 | 0.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BASEMENT | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.5053 | 2.5053 | 2.4927 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
RETAIL_1_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3376 | 0.3376 | 0.3359 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
RETAIL_2_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2502 | 0.2502 | 0.2489 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
MECH_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2637 | 0.2637 | 0.2624 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
STORAGE_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1315 | 0.1315 | 0.1309 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
LAUNDRY_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 3.3979 | 3.3979 | 3.3809 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CAFE_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.4578 | 1.4578 | 1.4505 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
LOBBY_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 4.8428 | 4.8428 | 4.8186 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_1_FLR_3 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0617 | 0.0617 | 0.0617 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_2_FLR_3 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0617 | 0.0617 | 0.0617 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_3_MULT19_FLR_3 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8371 | 0.8371 | 0.8371 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_4_MULT19_FLR_3 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8373 | 0.8373 | 0.8373 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_5_FLR_3 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0617 | 0.0617 | 0.0617 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_6_FLR_3 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0617 | 0.0617 | 0.0617 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORRIDOR_FLR_3 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.1628 | 1.1628 | 1.1570 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_1_FLR_6 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0154 | 0.0154 | 0.0154 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_2_FLR_6 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0154 | 0.0154 | 0.0154 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_3_MULT9_FLR_6 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0992 | 0.0992 | 0.0992 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
BANQUET_FLR_6 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.3260 | 2.3260 | 2.3144 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
DINING_FLR_6 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.4402 | 2.4402 | 2.4280 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
KITCHEN_FLR_6 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.3590 | 2.3590 | 2.3472 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORRIDOR_FLR_6 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7179 | 0.7179 | 0.7143 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
VAV WITH REHEAT | 22.1929 | 22.0819 | 22.1929 | 22.0819 | 0.0000 | 1.0000 |
FLR_3_DOAS | 2.0513 | 2.0513 | 2.0513 | 2.0513 | 0.0000 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BASEMENT | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.4927 | 2.4927 | 2.4927 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
RETAIL_1_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3359 | 0.3359 | 0.3359 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
RETAIL_2_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2489 | 0.2489 | 0.2489 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
MECH_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2624 | 0.2624 | 0.2624 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
STORAGE_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1309 | 0.1309 | 0.1309 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
LAUNDRY_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 3.3809 | 3.3809 | 3.3809 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CAFE_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.4505 | 1.4505 | 1.4505 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
LOBBY_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 4.8186 | 4.8186 | 4.8186 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_1_FLR_3 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0617 | 0.0617 | 0.0617 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_2_FLR_3 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0617 | 0.0617 | 0.0617 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_3_MULT19_FLR_3 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8371 | 0.8371 | 0.8371 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_4_MULT19_FLR_3 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.8373 | 0.8373 | 0.8373 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_5_FLR_3 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0617 | 0.0617 | 0.0617 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_6_FLR_3 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0617 | 0.0617 | 0.0617 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORRIDOR_FLR_3 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.1570 | 1.1570 | 1.1570 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_1_FLR_6 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0154 | 0.0154 | 0.0154 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_2_FLR_6 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0154 | 0.0154 | 0.0154 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_3_MULT9_FLR_6 | FLR_3_DOAS | AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT | 0.0992 | 0.0992 | 0.0992 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
BANQUET_FLR_6 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.3144 | 2.3144 | 2.3144 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
DINING_FLR_6 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.4280 | 2.4280 | 2.4280 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
KITCHEN_FLR_6 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.3472 | 2.3472 | 2.3472 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORRIDOR_FLR_6 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7143 | 0.7143 | 0.7143 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
VAV WITH REHEAT | 22.0819 | 22.0819 | 22.0819 | 22.0819 | 0.0000 | 1.0000 |
FLR_3_DOAS | 2.0513 | 2.0513 | 2.0513 | 2.0513 | 0.0000 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** Atlanta-Hartsfield Jackson Intl AP GA USA TMY3 WMO#=722190 |
Total gross floor area [m2] | 11345.29 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
BASEMENT | 1978.83 | 1978.83 | 0.00 | 168.00 |
RETAIL_1_FLR_1 | 67.07 | 67.07 | 0.00 | 168.00 |
RETAIL_2_FLR_1 | 77.67 | 77.67 | 0.00 | 168.00 |
MECH_FLR_1 | 164.24 | 164.24 | 0.00 | 168.00 |
STORAGE_FLR_1 | 94.76 | 94.76 | 0.00 | 168.00 |
LAUNDRY_FLR_1 | 78.04 | 78.04 | 0.00 | 168.00 |
CAFE_FLR_1 | 188.86 | 188.86 | 0.00 | 168.00 |
LOBBY_FLR_1 | 1308.19 | 1308.19 | 0.00 | 168.00 |
ROOM_1_FLR_3 | 39.02 | 39.02 | 0.00 | 168.00 |
ROOM_2_FLR_3 | 39.02 | 39.02 | 0.00 | 168.00 |
ROOM_3_MULT19_FLR_3 | 24.52 | 24.52 | 0.00 | 0.00 |
ROOM_4_MULT19_FLR_3 | 24.53 | 24.53 | 0.00 | 168.00 |
ROOM_5_FLR_3 | 39.02 | 39.02 | 0.00 | 168.00 |
ROOM_6_FLR_3 | 39.02 | 39.02 | 0.00 | 168.00 |
CORRIDOR_FLR_3 | 389.40 | 389.40 | 0.00 | 168.00 |
ROOM_1_FLR_6 | 39.02 | 39.02 | 0.00 | 168.00 |
ROOM_2_FLR_6 | 39.02 | 39.02 | 0.00 | 168.00 |
ROOM_3_MULT9_FLR_6 | 24.53 | 24.53 | 0.00 | 168.00 |
BANQUET_FLR_6 | 331.66 | 331.66 | 0.00 | 168.00 |
DINING_FLR_6 | 331.66 | 331.66 | 0.00 | 168.00 |
KITCHEN_FLR_6 | 103.30 | 103.30 | 0.00 | 168.00 |
CORRIDOR_FLR_6 | 412.12 | 412.12 | 0.00 | 168.00 |
Totals | 11345.29 | 11345.29 | 0.00 |
Data | |
Number of hours heating loads not met | 17.50 |
Number of hours cooling loads not met | 10.17 |
Number of hours not met | 27.67 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heating -- Boiler | 0.00 | 0.00 | 1265.44 | 345449.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heating -- Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- General | 2593.30 | 302320.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 1174.11 | 93091.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 262.45 | 16690.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 959.56 | 59492.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- Cooking | 762.04 | 29240.64 | 1198.64 | 74976.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- ReachInFreezer | 16.27 | 515.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- ReachInRefrigerator | 13.43 | 425.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- Laundry | 0.00 | 0.00 | 590.20 | 39726.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Transformer | 32.92 | 1912.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- ElevatorLift | 616.11 | 37691.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- ElevatorLightsFan | 30.65 | 972.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 1813.98 | 76570.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- General | 297.31 | 15178.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- General | 419.77 | 17414.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 90.78 | 4739.43 | 2989.27 | 273976.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- General | 18.27 | 2271.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- LowTempRefrigeration | 22.44 | 1906.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- MedTempRefrigeration | 34.04 | 1200.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 1826.04 | 9157.43 |
Natural Gas | 1788.84 | 6043.55 |
Additional | 0.00 | 0.00 |
Total | 3614.88 | 15200.98 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 103.49 |
Space Heating | 0.00 |
Space Cooling | 228.58 |
Fans (All) | 159.89 |
Service Water Heating | 8.00 |
Receptacle Equipment | 154.36 |
Miscellaneous (All) | 807.16 |
Subtotal | 807.16 |
Natural Gas [MJ/m2] | |
Space Heating | 111.54 |
Service Water Heating | 263.48 |
Miscellaneous (All) | 532.69 |
Subtotal | 532.69 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 7.72 |
Space Heating | 8.32 |
Space Cooling | 17.06 |
Fans (All) | 11.93 |
Service Water Heating | 20.26 |
Receptacle Equipment | 23.29 |
Miscellaneous | 11.41 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
LTG_SCH_KITCHEN | 3061. | 8760. |
LTG_SCH_DINING | 3061. | 8760. |
LTG_SCH_BASEMENT | 2655. | 8760. |
LTG_SCH_LOBBY | 3061. | 8760. |
LTG_SCH_STORAGE | 1339. | 8760. |
LTG_SCH_MECHANIC | 3061. | 8760. |
LTG_SCH_LAUNDRY | 2678. | 8760. |
LTG_SCH_GUESTROOM | 3599. | 8760. |
LTG_SCH_CORRIDOR | 3061. | 8760. |
LTG_SCH_RETAIL | 2678. | 8760. |
WALKIN_OCC_LGHT_SCH_1 | 3061. | 8760. |
EXTERIOR_LTG_SCH | 4380. | 4380. |
BASEMENT_EQUIP_SCH | 3924. | 8760. |
BLDG_EQUIP_SCH | 3924. | 8760. |
GUESTROOM_EQP_SCH_BASE | 3239. | 8760. |
GUESTROOM_EQP_SCH_ADVA | 2762. | 8760. |
LOBBY_EQP_SCH | 3292. | 8760. |
OFFICE_EQP_SCH | 4941. | 8760. |
EMPLOYEELOUNGE_EQP_SCH | 4044. | 8760. |
LAUNDRYROOM_EQP_ELEC_SCH | 2920. | 2920. |
LAUNDRYROOM_EQP_GAS_SCH | 2920. | 2920. |
MEETINGROOM_EQP_SCH | 1336. | 4745. |
EXERCISEROOM_EQP_SCH | 3832. | 5840. |
KITCHEN_ELEC_EQUIP_SCH | 2172. | 8760. |
KITCHEN_GAS_EQUIP_SCH | 1332. | 8760. |
KITCHEN_EXHAUST_SCH | 6205. | 6205. |
BLDG_ELEVATORS | 2270. | 8760. |
ELEV_LIGHT_FAN_SCH_24_7 | 8760. | 8760. |
ELEV_LIGHT_FAN_SCH_ADD_DF | 2154. | 8760. |
BLDG_OCC_SCH | 5026. | 8760. |
GUESTROOM_OCC_SCH | 5515. | 8760. |
LOBBY_OCC_SCH | 2304. | 8760. |
OFFICE_OCC_SCH | 3954. | 8760. |
EMPLOYEELOUNGE_OCC_SCH | 948. | 5475. |
MEETINGROOM_OCC_SCH | 1168. | 4745. |
LAUNDRYROOM_OCC_SCH | 427. | 2920. |
EXERCISEROOM_OCC_SCH | 5292. | 5840. |
INFIL_SCH | 8760. | 8760. |
INFIL_HALF_ON_SCH | 4380. | 8760. |
INFIL_QUARTER_ON_SCH | 2190. | 8760. |
LAUNDRY_SWH_SCH | 2555. | 2555. |
BLDG_SWH_SCH | 3301. | 8760. |
GUESTROOM_SWH_SCH | 2899. | 8760. |
LAUNDRYROOM_SWH_SCH | 2920. | 2920. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
ALWAYS_ON | 8760. | 8760. |
ALWAYS_OFF | 0. | 0. |
FAN_SCH | 8760. | 8760. |
REHEATCOILAVAILSCHED | 8760. | 8760. |
COOLINGCOILAVAILSCHED | 8760. | 8760. |
OCC_GUESTROOM_VENT_CTRL_30MIN | 6570. | 6570. |
OCC_GUESTROOM_VENT_CTRL_20MIN | 6327. | 6327. |
VAC_GUESTROOM_VENTILATION_SCHEDULE | 365. | 365. |
MINOA_MOTORIZEDDAMPER_SCHED | 8760. | 8760. |
MINOA_SCHED | 8760. | 8760. |
WORK_EFF_SCH | 0. | 0. |
ROOM_1_FLR_3 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_1_FLR_3 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
ROOM_2_FLR_3 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_2_FLR_3 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
ROOM_3_MULT19_FLR_3 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_3_MULT19_FLR_3 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
ROOM_4_MULT19_FLR_3 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_4_MULT19_FLR_3 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
ROOM_5_FLR_3 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_5_FLR_3 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
ROOM_6_FLR_3 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_6_FLR_3 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
ROOM_1_FLR_6 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_1_FLR_6 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
ROOM_2_FLR_6 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_2_FLR_6 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
ROOM_3_MULT9_FLR_6 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_3_MULT9_FLR_6 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
KITCHEN_FLR_6 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
KITCHEN_FLR_6 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
KITCHEN_FLR_6_CASE:1_WALKINFREEZER_CASECREDITREDUXSCHED | 2774. | 8760. |
FLR_3_DOAS_OAMINOAFRACSCHEDULE | 8760. | 8760. |
KITCHEN EXHAUST FAN BALANCED EXHAUST FRACTION SCHEDULE | 0. | 0. |
LAUNDRY_FLR_1 EXHAUST FAN BALANCED EXHAUST FRACTION SCHEDULE | 0. | 0. |
SLIDING_DOORS_VENTILATION_AVAILABILITY_SCH | 3285. | 3285. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
VACGUESTROOM_HTGSP_SCH | VACGUESTROOM THERMOSTAT DUAL SP CONTROL | January | 18.89 | 365 | 18.89 | 365 |
VACGUESTROOM_CLGSP_SCH | VACGUESTROOM THERMOSTAT DUAL SP CONTROL | July | 23.33 | 365 | 23.33 | 365 |
OBCRESET_S_OCCGUESTROOM_HTGSP_SCH_30MIN | S OCCGUESTROOM THERMOSTAT DUAL SP CONTROL | January | 21.11 | 365 | 21.11 | 365 |
OBCRESET_S_OCCGUESTROOM_CLGSP_SCH_30MIN | S OCCGUESTROOM THERMOSTAT DUAL SP CONTROL | July | 23.33 | 365 | 21.11 | 365 |
OBCRESET_N_OCCGUESTROOM_HTGSP_SCH_30MIN | N OCCGUESTROOM THERMOSTAT DUAL SP CONTROL | January | 21.11 | 365 | 21.11 | 365 |
OBCRESET_N_OCCGUESTROOM_CLGSP_SCH_30MIN | N OCCGUESTROOM THERMOSTAT DUAL SP CONTROL | July | 23.33 | 365 | 21.11 | 365 |
HTGSETP_SCH | BASEMENT DUAL SP CONTROL | January | 21.00 | 365 | 21.00 | 365 |
CLGSETP_SCH | BASEMENT DUAL SP CONTROL | July | 24.00 | 365 | 24.00 | 365 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
Heat Index HoursSafe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
BASEMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_1_FLR_1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_2_FLR_1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MECH_FLR_1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
STORAGE_FLR_1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
LAUNDRY_FLR_1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CAFE_FLR_1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
LOBBY_FLR_1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_3 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_3 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_3_MULT19_FLR_3 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_4_MULT19_FLR_3 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_5_FLR_3 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_6_FLR_3 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_3 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_6 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_6 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_3_MULT9_FLR_6 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
BANQUET_FLR_6 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
DINING_FLR_6 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
KITCHEN_FLR_6 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_6 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Average | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Sum | 192720.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
BASEMENT | 529331.00 | 0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_1_FLR_1 | 50179.00 | 0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_2_FLR_1 | 59156.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MECH_FLR_1 | 8977.00 | 0.00 | 0.00 | 0.00 | 0.00 |
STORAGE_FLR_1 | 5588.00 | 0.00 | 0.00 | 0.00 | 0.00 |
LAUNDRY_FLR_1 | 37203.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CAFE_FLR_1 | 710417.00 | 0.00 | 0.00 | 0.00 | 0.00 |
LOBBY_FLR_1 | 2115429.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_3 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_3 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_3_MULT19_FLR_3 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_4_MULT19_FLR_3 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_5_FLR_3 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_6_FLR_3 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_3 | 100358.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_6 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_6 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_3_MULT9_FLR_6 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
BANQUET_FLR_6 | 1245715.00 | 0.00 | 0.00 | 0.00 | 0.00 |
DINING_FLR_6 | 1245715.00 | 0.00 | 0.00 | 0.00 | 0.00 |
KITCHEN_FLR_6 | 108269.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_6 | 105946.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 2115429.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Average | 288887.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Sum | 6355515.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
BASEMENT | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_1_FLR_1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_2_FLR_1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MECH_FLR_1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
STORAGE_FLR_1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
LAUNDRY_FLR_1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CAFE_FLR_1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
LOBBY_FLR_1 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_3 | 8759.50 | 0.50 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_3 | 8759.67 | 0.33 | 0.00 | 0.00 | 0.00 |
ROOM_3_MULT19_FLR_3 | 8751.17 | 8.83 | 0.00 | 0.00 | 0.00 |
ROOM_4_MULT19_FLR_3 | 8759.50 | 0.50 | 0.00 | 0.00 | 0.00 |
ROOM_5_FLR_3 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_6_FLR_3 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_3 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_6 | 8754.67 | 5.33 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_6 | 8755.67 | 4.33 | 0.00 | 0.00 | 0.00 |
ROOM_3_MULT9_FLR_6 | 8754.33 | 5.67 | 0.00 | 0.00 | 0.00 |
BANQUET_FLR_6 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
DINING_FLR_6 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
KITCHEN_FLR_6 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_6 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 8751.17 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 8760.00 | 8.83 | 0.00 | 0.00 | 0.00 |
Average | 8758.84 | 1.16 | 0.00 | 0.00 | 0.00 |
Sum | 192694.50 | 25.50 | 0.00 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
BASEMENT | 529331.00 | 0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_1_FLR_1 | 50179.00 | 0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_2_FLR_1 | 59156.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MECH_FLR_1 | 8977.00 | 0.00 | 0.00 | 0.00 | 0.00 |
STORAGE_FLR_1 | 5588.00 | 0.00 | 0.00 | 0.00 | 0.00 |
LAUNDRY_FLR_1 | 37203.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CAFE_FLR_1 | 710417.00 | 0.00 | 0.00 | 0.00 | 0.00 |
LOBBY_FLR_1 | 2115429.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_3 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_3 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_3_MULT19_FLR_3 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_4_MULT19_FLR_3 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_5_FLR_3 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_6_FLR_3 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_3 | 100358.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_6 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_6 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_3_MULT9_FLR_6 | 4154.00 | 0.00 | 0.00 | 0.00 | 0.00 |
BANQUET_FLR_6 | 1245715.00 | 0.00 | 0.00 | 0.00 | 0.00 |
DINING_FLR_6 | 1245715.00 | 0.00 | 0.00 | 0.00 | 0.00 |
KITCHEN_FLR_6 | 108269.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_6 | 105946.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 2115429.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Average | 288887.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Sum | 6355515.00 | 0.00 | 0.00 | 0.00 | 0.00 |
SET ≤ 12.2°C Hours (°C) | SET ≤ 12.2°C OccupantHours (°C) | Longest SET ≤ 12.2°C Duration [hr] | Start Time of the Longest SET ≤ 12.2°C Duration | |
None |
SET > 30°C Hours (°C) | SET > 30°C OccupantHours (°C) | Longest SET > 30°C Duration [hr] | Start Time of the Longest SET > 30°C Duration | |
None |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
CO2 Level HoursSafe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 08:58:01
Illuminance Level HoursA Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
None |
A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
None |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Environment
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 3.965 |
February | 7.937 |
March | 13.764 |
April | 17.213 |
May | 20.837 |
June | 24.797 |
July | 26.063 |
August | 26.547 |
September | 22.525 |
October | 16.026 |
November | 11.940 |
December | 7.696 |
Annual Sum or Average | 16.653 |
Minimum of Months | 3.965 |
Maximum of Months | 26.547 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Environment
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 3.965 |
February | 7.937 |
March | 13.764 |
April | 17.213 |
May | 20.837 |
June | 24.797 |
July | 26.063 |
August | 26.547 |
September | 22.525 |
October | 16.026 |
November | 11.940 |
December | 7.696 |
Annual Sum or Average | 16.653 |
Minimum of Months | 3.965 |
Maximum of Months | 26.547 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2012
For: Environment
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 3.965 |
February | 7.937 |
March | 13.764 |
April | 17.213 |
May | 20.837 |
June | 24.797 |
July | 26.063 |
August | 26.547 |
September | 22.525 |
October | 16.026 |
November | 11.940 |
December | 7.696 |
Annual Sum or Average | 16.653 |
Minimum of Months | 3.965 |
Maximum of Months | 26.547 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Environment
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 3.965 |
February | 7.937 |
March | 13.764 |
April | 17.213 |
May | 20.837 |
June | 24.797 |
July | 26.063 |
August | 26.547 |
September | 22.525 |
October | 16.026 |
November | 11.940 |
December | 7.696 |
Annual Sum or Average | 16.653 |
Minimum of Months | 3.965 |
Maximum of Months | 26.547 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME HOTELLARGE
For: Environment
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 3.965 |
February | 7.937 |
March | 13.764 |
April | 17.213 |
May | 20.837 |
June | 24.797 |
July | 26.063 |
August | 26.547 |
September | 22.525 |
October | 16.026 |
November | 11.940 |
December | 7.696 |
Annual Sum or Average | 16.653 |
Minimum of Months | 3.965 |
Maximum of Months | 26.547 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Environment
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 3.965 |
February | 7.937 |
March | 13.764 |
April | 17.213 |
May | 20.837 |
June | 24.797 |
July | 26.063 |
August | 26.547 |
September | 22.525 |
October | 16.026 |
November | 11.940 |
December | 7.696 |
Annual Sum or Average | 16.653 |
Minimum of Months | 3.965 |
Maximum of Months | 26.547 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Environment
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 3.965 |
February | 7.937 |
March | 13.764 |
April | 17.213 |
May | 20.837 |
June | 24.797 |
July | 26.063 |
August | 26.547 |
September | 22.525 |
October | 16.026 |
November | 11.940 |
December | 7.696 |
Annual Sum or Average | 16.653 |
Minimum of Months | 3.965 |
Maximum of Months | 26.547 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 3A
For: Environment
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 3.965 |
February | 7.937 |
March | 13.764 |
April | 17.213 |
May | 20.837 |
June | 24.797 |
July | 26.063 |
August | 26.547 |
September | 22.525 |
October | 16.026 |
November | 11.940 |
December | 7.696 |
Annual Sum or Average | 16.653 |
Minimum of Months | 3.965 |
Maximum of Months | 26.547 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_GA_ATLANTA
For: Environment
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 3.965 |
February | 7.937 |
March | 13.764 |
April | 17.213 |
May | 20.837 |
June | 24.797 |
July | 26.063 |
August | 26.547 |
September | 22.525 |
October | 16.026 |
November | 11.940 |
December | 7.696 |
Annual Sum or Average | 16.653 |
Minimum of Months | 3.965 |
Maximum of Months | 26.547 |
Report: ZoneCoolingSummaryMonthly
For: BASEMENT
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.371446E+11 | 18881.66 | 19-JAN-19:10 | 17.30 | 16.17 | 0.616043E+10 | 3816.45 | 27-JAN-22:10 | -0.7 | -4.0 |
February | 0.299217E+11 | 18642.19 | 27-FEB-19:50 | 19.08 | 10.30 | 0.553738E+10 | 3761.69 | 01-FEB-22:10 | 19.08 | 10.30 |
March | 0.288862E+11 | 18298.63 | 29-MAR-20:00 | 23.90 | 17.22 | 0.612601E+10 | 3678.58 | 01-MAR-22:10 | 23.90 | 17.22 |
April | 0.240937E+11 | 16405.89 | 06-APR-20:50 | 9.78 | 4.81 | 0.587643E+10 | 3581.35 | 24-APR-21:49 | 12.88 | 10.45 |
May | 0.290422E+11 | 18831.87 | 15-MAY-19:40 | 25.33 | 15.64 | 0.609313E+10 | 3632.73 | 24-MAY-21:10 | 18.80 | 17.40 |
June | 0.345493E+11 | 22645.47 | 07-JUN-18:03 | 23.12 | 13.70 | 0.594084E+10 | 3721.62 | 09-JUN-22:10 | 21.52 | 12.48 |
July | 0.394045E+11 | 21713.39 | 06-JUL-19:10 | 31.23 | 24.06 | 0.613781E+10 | 3793.56 | 28-JUL-21:10 | 18.22 | 17.89 |
August | 0.433896E+11 | 22932.45 | 10-AUG-18:08 | 31.52 | 24.11 | 0.624064E+10 | 3848.97 | 25-AUG-22:10 | 25.40 | 18.24 |
September | 0.455360E+11 | 22879.00 | 07-SEP-18:10 | 29.72 | 22.85 | 0.615564E+10 | 3966.97 | 29-SEP-21:10 | 19.22 | 16.17 |
October | 0.478673E+11 | 24758.38 | 11-OCT-17:10 | 24.03 | 13.79 | 0.647335E+10 | 4058.05 | 05-OCT-21:10 | 24.03 | 13.79 |
November | 0.463939E+11 | 21418.43 | 02-NOV-18:10 | 19.32 | 15.32 | 0.633446E+10 | 4090.46 | 22-NOV-22:10 | 4.82 | 1.08 |
December | 0.443115E+11 | 19996.91 | 13-DEC-19:10 | 16.10 | 16.05 | 0.633717E+10 | 4041.51 | 01-DEC-22:10 | 16.10 | 16.05 |
Annual Sum or Average | 0.450540E+12 | 0.734133E+11 | ||||||||
Minimum of Months | 0.240937E+11 | 16405.89 | 9.78 | 4.81 | 0.553738E+10 | 3581.35 | -0.7 | -4.0 | ||
Maximum of Months | 0.478673E+11 | 24758.38 | 31.52 | 24.11 | 0.647335E+10 | 4090.46 | 25.40 | 18.24 |
Report: ZoneCoolingSummaryMonthly
For: RETAIL_1_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.105280E+10 | 2678.84 | 29-JAN-11:40 | 12.43 | 5.39 | 0.618505E+09 | 364.23 | 20-JAN-02:20 | 12.43 | 5.39 |
February | 0.153446E+10 | 2886.07 | 26-FEB-11:35 | 22.07 | 11.70 | 0.559848E+09 | 364.26 | 01-FEB-01:39 | 22.07 | 11.70 |
March | 0.299246E+10 | 2889.59 | 30-MAR-15:15 | 27.80 | 17.21 | 0.624127E+09 | 378.27 | 30-MAR-21:19 | 23.53 | 16.75 |
April | 0.352421E+10 | 2871.97 | 12-APR-15:15 | 28.13 | 16.55 | 0.602210E+09 | 368.95 | 17-APR-21:30 | 20.00 | 13.99 |
May | 0.442140E+10 | 3059.62 | 15-MAY-18:56 | 27.20 | 15.84 | 0.622083E+09 | 379.56 | 17-MAY-21:19 | 23.90 | 16.97 |
June | 0.523604E+10 | 3089.77 | 12-JUN-18:10 | 31.60 | 21.71 | 0.606179E+09 | 393.40 | 13-JUN-21:49 | 27.38 | 21.12 |
July | 0.576335E+10 | 3308.58 | 08-JUL-17:25 | 34.40 | 23.36 | 0.628633E+09 | 405.08 | 07-JUL-21:00 | 34.40 | 23.36 |
August | 0.613353E+10 | 3342.76 | 19-AUG-10:35 | 32.03 | 24.19 | 0.635854E+09 | 411.69 | 18-AUG-21:49 | 32.03 | 24.19 |
September | 0.479728E+10 | 3290.42 | 25-SEP-10:35 | 27.77 | 19.43 | 0.606702E+09 | 392.21 | 07-SEP-21:40 | 27.77 | 19.43 |
October | 0.362752E+10 | 3480.15 | 11-OCT-17:10 | 24.03 | 13.79 | 0.624332E+09 | 380.76 | 10-OCT-21:19 | 24.03 | 13.79 |
November | 0.251190E+10 | 2983.98 | 11-NOV-11:35 | 18.50 | 11.57 | 0.601645E+09 | 364.24 | 08-NOV-05:10 | 18.50 | 11.57 |
December | 0.154304E+10 | 2825.59 | 12-DEC-11:40 | 19.83 | 16.13 | 0.620371E+09 | 364.25 | 01-DEC-00:49 | 19.83 | 16.13 |
Annual Sum or Average | 0.431380E+11 | 0.735049E+10 | ||||||||
Minimum of Months | 0.105280E+10 | 2678.84 | 12.43 | 5.39 | 0.559848E+09 | 364.23 | 12.43 | 5.39 | ||
Maximum of Months | 0.613353E+10 | 3480.15 | 34.40 | 24.19 | 0.635854E+09 | 411.69 | 34.40 | 24.19 |
Report: ZoneCoolingSummaryMonthly
For: RETAIL_2_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.218063E+10 | 1806.64 | 31-JAN-21:00 | 17.20 | 12.43 | 0.717775E+09 | 437.33 | 31-JAN-22:00 | 12.60 | 9.92 |
February | 0.233154E+10 | 1928.70 | 27-FEB-19:20 | 19.63 | 10.47 | 0.650208E+09 | 450.56 | 28-FEB-22:40 | 17.83 | 10.34 |
March | 0.332241E+10 | 2225.01 | 11-MAR-19:01 | 23.12 | 14.94 | 0.726867E+09 | 465.33 | 30-MAR-22:10 | 22.62 | 16.35 |
April | 0.356122E+10 | 2275.25 | 07-APR-18:10 | 23.43 | 13.72 | 0.704333E+09 | 463.87 | 14-APR-21:40 | 18.13 | 12.83 |
May | 0.401895E+10 | 2360.28 | 15-MAY-18:56 | 27.20 | 15.84 | 0.732984E+09 | 471.81 | 19-MAY-21:40 | 22.77 | 15.87 |
June | 0.425869E+10 | 2428.97 | 07-JUN-18:03 | 23.12 | 13.70 | 0.720409E+09 | 477.44 | 13-JUN-22:10 | 27.12 | 20.92 |
July | 0.451145E+10 | 2357.50 | 06-JUL-18:10 | 32.12 | 24.13 | 0.744995E+09 | 485.73 | 07-JUL-22:10 | 29.13 | 22.71 |
August | 0.460750E+10 | 2367.81 | 02-AUG-18:10 | 32.80 | 23.11 | 0.751912E+09 | 487.21 | 18-AUG-22:10 | 29.32 | 23.10 |
September | 0.401828E+10 | 2285.80 | 07-SEP-18:10 | 29.72 | 22.85 | 0.711611E+09 | 477.16 | 08-SEP-22:10 | 24.82 | 21.45 |
October | 0.354250E+10 | 2424.66 | 11-OCT-17:10 | 24.03 | 13.79 | 0.725204E+09 | 464.71 | 10-OCT-22:10 | 24.03 | 13.79 |
November | 0.299052E+10 | 1898.85 | 02-NOV-18:30 | 19.15 | 15.26 | 0.696945E+09 | 445.43 | 02-NOV-21:19 | 16.83 | 14.35 |
December | 0.256113E+10 | 1856.72 | 12-DEC-21:00 | 18.30 | 14.62 | 0.718362E+09 | 444.69 | 12-DEC-22:19 | 18.30 | 14.70 |
Annual Sum or Average | 0.419048E+11 | 0.860161E+10 | ||||||||
Minimum of Months | 0.218063E+10 | 1806.64 | 17.20 | 10.47 | 0.650208E+09 | 437.33 | 12.60 | 9.92 | ||
Maximum of Months | 0.460750E+10 | 2428.97 | 32.80 | 24.13 | 0.751912E+09 | 487.21 | 29.32 | 23.10 |
Report: ZoneCoolingSummaryMonthly
For: MECH_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.610294E+09 | 1685.86 | 31-JAN-21:00 | 17.20 | 12.43 | 0.151675E+09 | 89.15 | 14-JAN-05:49 | 17.20 | 12.43 |
February | 0.110506E+10 | 1916.30 | 28-FEB-21:00 | 20.60 | 11.78 | 0.137099E+09 | 90.44 | 28-FEB-22:10 | 18.63 | 10.80 |
March | 0.225086E+10 | 2135.87 | 30-MAR-18:40 | 25.77 | 17.51 | 0.152513E+09 | 93.08 | 30-MAR-21:19 | 23.53 | 16.75 |
April | 0.285664E+10 | 2179.59 | 17-APR-19:10 | 24.63 | 15.85 | 0.147360E+09 | 92.89 | 18-APR-21:10 | 19.90 | 15.31 |
May | 0.373403E+10 | 2404.27 | 15-MAY-18:56 | 27.20 | 15.84 | 0.152981E+09 | 95.07 | 19-MAY-21:10 | 23.62 | 16.17 |
June | 0.438730E+10 | 2523.16 | 07-JUN-18:03 | 23.12 | 13.70 | 0.149835E+09 | 97.32 | 13-JUN-22:10 | 27.12 | 20.92 |
July | 0.474317E+10 | 2493.71 | 08-JUL-18:10 | 33.95 | 23.39 | 0.155034E+09 | 98.91 | 07-JUL-22:10 | 33.95 | 23.39 |
August | 0.480586E+10 | 2467.13 | 02-AUG-18:10 | 32.80 | 23.11 | 0.155780E+09 | 98.28 | 18-AUG-22:10 | 29.32 | 23.10 |
September | 0.381372E+10 | 2370.21 | 07-SEP-18:10 | 29.72 | 22.85 | 0.148091E+09 | 95.71 | 06-SEP-22:10 | 29.72 | 22.85 |
October | 0.270089E+10 | 2099.74 | 18-OCT-18:30 | 24.15 | 22.69 | 0.151977E+09 | 92.97 | 18-OCT-21:10 | 23.22 | 22.46 |
November | 0.184337E+10 | 1900.50 | 03-NOV-20:00 | 18.90 | 16.38 | 0.146757E+09 | 90.56 | 03-NOV-21:10 | 18.22 | 16.16 |
December | 0.105823E+10 | 1841.80 | 12-DEC-21:00 | 18.30 | 14.62 | 0.151699E+09 | 89.58 | 12-DEC-22:10 | 18.30 | 14.66 |
Annual Sum or Average | 0.339094E+11 | 0.180080E+10 | ||||||||
Minimum of Months | 0.610294E+09 | 1685.86 | 17.20 | 11.78 | 0.137099E+09 | 89.15 | 17.20 | 10.80 | ||
Maximum of Months | 0.480586E+10 | 2523.16 | 33.95 | 23.39 | 0.155780E+09 | 98.91 | 33.95 | 23.39 |
Report: ZoneCoolingSummaryMonthly
For: STORAGE_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 99185676.08 | 550.20 | 31-JAN-21:00 | 17.20 | 12.43 | 0.116579E+09 | 68.58 | 26-JAN-03:39 | 17.20 | 12.43 |
February | 0.313197E+09 | 735.49 | 28-FEB-21:50 | 19.18 | 11.10 | 0.105353E+09 | 68.59 | 01-FEB-01:19 | 19.18 | 11.10 |
March | 0.787537E+09 | 946.49 | 30-MAR-20:10 | 24.32 | 16.97 | 0.117244E+09 | 69.41 | 30-MAR-22:10 | 22.62 | 16.35 |
April | 0.115927E+10 | 912.81 | 18-APR-20:00 | 21.70 | 16.13 | 0.113128E+09 | 68.95 | 18-APR-21:40 | 19.60 | 14.79 |
May | 0.167456E+10 | 1048.81 | 18-MAY-19:50 | 26.38 | 17.72 | 0.117049E+09 | 70.62 | 19-MAY-21:49 | 22.48 | 15.77 |
June | 0.209659E+10 | 1147.69 | 28-JUN-18:30 | 30.30 | 23.47 | 0.114168E+09 | 72.58 | 13-JUN-22:10 | 30.30 | 23.47 |
July | 0.229547E+10 | 1225.61 | 08-JUL-18:10 | 33.95 | 23.39 | 0.118096E+09 | 73.79 | 07-JUL-22:10 | 33.95 | 23.39 |
August | 0.233653E+10 | 1203.24 | 02-AUG-18:02 | 32.80 | 23.11 | 0.118608E+09 | 73.37 | 18-AUG-22:10 | 29.32 | 23.10 |
September | 0.173938E+10 | 1099.54 | 07-SEP-19:10 | 28.12 | 22.72 | 0.113271E+09 | 71.39 | 06-SEP-22:10 | 28.12 | 22.72 |
October | 0.104672E+10 | 927.93 | 18-OCT-20:20 | 23.30 | 22.56 | 0.116753E+09 | 69.32 | 18-OCT-22:10 | 22.80 | 22.03 |
November | 0.580285E+09 | 730.08 | 03-NOV-21:00 | 18.30 | 16.18 | 0.112879E+09 | 68.58 | 20-NOV-02:39 | 14.23 | 11.92 |
December | 0.209846E+09 | 664.15 | 12-DEC-22:00 | 18.30 | 14.62 | 0.116691E+09 | 68.58 | 07-DEC-01:30 | 18.30 | 14.62 |
Annual Sum or Average | 0.143386E+11 | 0.137982E+10 | ||||||||
Minimum of Months | 99185676.08 | 550.20 | 17.20 | 11.10 | 0.105353E+09 | 68.58 | 14.23 | 11.10 | ||
Maximum of Months | 0.233653E+10 | 1225.61 | 33.95 | 23.47 | 0.118608E+09 | 73.79 | 33.95 | 23.47 |
Report: ZoneCoolingSummaryMonthly
For: LAUNDRY_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.476787E+11 | 36002.87 | 31-JAN-21:00 | 17.20 | 12.43 | 0.509851E+09 | 388.52 | 30-JAN-22:10 | 17.20 | 12.43 |
February | 0.441079E+11 | 36467.45 | 28-FEB-21:00 | 20.60 | 11.78 | 0.460985E+09 | 386.95 | 15-FEB-22:10 | 20.60 | 11.78 |
March | 0.508019E+11 | 37013.05 | 30-MAR-20:00 | 24.40 | 16.98 | 0.512858E+09 | 392.17 | 06-MAR-22:10 | 24.40 | 16.98 |
April | 0.501340E+11 | 37804.61 | 07-APR-18:10 | 23.43 | 13.72 | 0.492971E+09 | 382.17 | 24-APR-21:10 | 13.22 | 9.86 |
May | 0.530409E+11 | 38804.01 | 15-MAY-18:56 | 27.20 | 15.84 | 0.509258E+09 | 383.19 | 19-MAY-21:10 | 23.62 | 16.17 |
June | 0.524550E+11 | 37785.58 | 12-JUN-20:00 | 28.30 | 21.75 | 0.493122E+09 | 382.03 | 02-JUN-21:10 | 28.30 | 21.75 |
July | 0.543884E+11 | 38047.38 | 06-JUL-20:00 | 28.90 | 23.64 | 0.505863E+09 | 381.83 | 28-JUL-21:10 | 18.22 | 17.89 |
August | 0.546615E+11 | 38164.53 | 02-AUG-20:00 | 30.60 | 23.37 | 0.509616E+09 | 381.81 | 25-AUG-21:10 | 26.02 | 18.49 |
September | 0.513594E+11 | 37757.55 | 07-SEP-20:00 | 27.20 | 22.45 | 0.491989E+09 | 381.87 | 19-SEP-21:10 | 19.72 | 15.39 |
October | 0.512384E+11 | 36878.26 | 02-OCT-20:00 | 21.70 | 19.37 | 0.509427E+09 | 400.08 | 05-OCT-21:10 | 12.70 | 10.51 |
November | 0.484278E+11 | 36334.86 | 03-NOV-20:00 | 18.90 | 16.38 | 0.493663E+09 | 383.28 | 16-NOV-22:10 | 11.70 | 8.09 |
December | 0.485875E+11 | 36157.22 | 12-DEC-21:00 | 18.30 | 14.62 | 0.509756E+09 | 386.55 | 29-DEC-22:10 | 12.02 | 6.15 |
Annual Sum or Average | 0.606881E+12 | 0.599936E+10 | ||||||||
Minimum of Months | 0.441079E+11 | 36002.87 | 17.20 | 11.78 | 0.460985E+09 | 381.81 | 11.70 | 6.15 | ||
Maximum of Months | 0.546615E+11 | 38804.01 | 30.60 | 23.64 | 0.512858E+09 | 400.08 | 28.30 | 21.75 |
Report: ZoneCoolingSummaryMonthly
For: CAFE_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.148547E+11 | 11665.10 | 29-JAN-11:40 | 12.43 | 5.39 | 0.815358E+10 | 5068.02 | 31-JAN-22:00 | 12.60 | 9.92 |
February | 0.156169E+11 | 12367.70 | 26-FEB-11:35 | 22.07 | 11.70 | 0.740218E+10 | 5276.44 | 28-FEB-22:30 | 18.10 | 10.49 |
March | 0.215040E+11 | 13055.11 | 11-MAR-19:01 | 23.12 | 14.94 | 0.830781E+10 | 5473.98 | 30-MAR-21:40 | 23.17 | 16.60 |
April | 0.221458E+11 | 13365.97 | 07-APR-18:10 | 23.43 | 13.72 | 0.805424E+10 | 5378.68 | 17-APR-21:40 | 20.00 | 13.94 |
May | 0.246320E+11 | 13772.85 | 15-MAY-18:56 | 27.20 | 15.84 | 0.841442E+10 | 5506.98 | 17-MAY-21:19 | 23.90 | 16.97 |
June | 0.259360E+11 | 14062.97 | 07-JUN-18:03 | 23.12 | 13.70 | 0.832184E+10 | 5619.89 | 13-JUN-22:10 | 27.12 | 20.92 |
July | 0.276559E+11 | 13911.43 | 13-JUL-18:10 | 32.70 | 22.67 | 0.863342E+10 | 5703.78 | 07-JUL-22:10 | 32.70 | 22.67 |
August | 0.286246E+11 | 14033.27 | 02-AUG-18:10 | 32.80 | 23.11 | 0.878019E+10 | 5752.80 | 18-AUG-21:49 | 29.68 | 23.03 |
September | 0.251942E+11 | 13530.87 | 24-SEP-10:35 | 27.23 | 19.06 | 0.826593E+10 | 5595.17 | 07-SEP-21:40 | 27.23 | 19.06 |
October | 0.231481E+11 | 14836.95 | 11-OCT-17:10 | 24.03 | 13.79 | 0.835033E+10 | 5497.62 | 10-OCT-21:40 | 24.03 | 13.79 |
November | 0.199213E+11 | 12736.35 | 11-NOV-11:35 | 18.50 | 11.57 | 0.795985E+10 | 5207.53 | 01-NOV-21:30 | 18.50 | 11.57 |
December | 0.173869E+11 | 11939.23 | 10-DEC-11:40 | 12.93 | 6.50 | 0.817398E+10 | 5243.73 | 12-DEC-22:40 | 18.30 | 14.79 |
Annual Sum or Average | 0.266620E+12 | 0.988178E+11 | ||||||||
Minimum of Months | 0.148547E+11 | 11665.10 | 12.43 | 5.39 | 0.740218E+10 | 5068.02 | 12.60 | 9.92 | ||
Maximum of Months | 0.286246E+11 | 14836.95 | 32.80 | 23.11 | 0.878019E+10 | 5752.80 | 32.70 | 23.03 |
Report: ZoneCoolingSummaryMonthly
For: LOBBY_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.580567E+11 | 36461.88 | 31-JAN-21:00 | 17.20 | 12.43 | 0.242843E+11 | 15503.27 | 31-JAN-22:00 | 12.60 | 9.92 |
February | 0.580201E+11 | 38543.89 | 27-FEB-19:10 | 19.82 | 10.52 | 0.220943E+11 | 15878.95 | 28-FEB-22:40 | 17.83 | 10.34 |
March | 0.747177E+11 | 44019.66 | 11-MAR-19:01 | 23.12 | 14.94 | 0.249152E+11 | 16258.89 | 30-MAR-22:10 | 22.62 | 16.35 |
April | 0.765689E+11 | 44647.51 | 07-APR-18:10 | 23.43 | 13.72 | 0.242071E+11 | 16104.76 | 17-APR-22:10 | 19.72 | 13.80 |
May | 0.841363E+11 | 46411.05 | 15-MAY-18:56 | 27.20 | 15.84 | 0.253398E+11 | 16377.18 | 19-MAY-21:40 | 22.77 | 15.87 |
June | 0.872583E+11 | 47153.24 | 07-JUN-18:03 | 23.12 | 13.70 | 0.249707E+11 | 16663.71 | 13-JUN-22:10 | 27.12 | 20.92 |
July | 0.921731E+11 | 46007.70 | 13-JUL-18:10 | 32.70 | 22.67 | 0.258051E+11 | 16846.10 | 07-JUL-22:10 | 32.70 | 22.67 |
August | 0.939808E+11 | 46117.59 | 02-AUG-18:10 | 32.80 | 23.11 | 0.260762E+11 | 16872.07 | 18-AUG-22:10 | 29.32 | 23.10 |
September | 0.843495E+11 | 44634.86 | 07-SEP-18:10 | 29.72 | 22.85 | 0.246795E+11 | 16544.91 | 06-SEP-22:10 | 29.72 | 22.85 |
October | 0.788056E+11 | 47163.55 | 11-OCT-17:10 | 24.03 | 13.79 | 0.249402E+11 | 16221.46 | 10-OCT-22:10 | 24.03 | 13.79 |
November | 0.700912E+11 | 38454.56 | 02-NOV-18:10 | 19.32 | 15.32 | 0.238139E+11 | 15747.22 | 02-NOV-21:40 | 16.47 | 14.23 |
December | 0.645247E+11 | 37393.14 | 12-DEC-21:00 | 18.30 | 14.62 | 0.243916E+11 | 15767.58 | 12-DEC-23:10 | 18.22 | 14.85 |
Annual Sum or Average | 0.922683E+12 | 0.295518E+12 | ||||||||
Minimum of Months | 0.580201E+11 | 36461.88 | 17.20 | 10.52 | 0.220943E+11 | 15503.27 | 12.60 | 9.92 | ||
Maximum of Months | 0.939808E+11 | 47163.55 | 32.80 | 23.11 | 0.260762E+11 | 16872.07 | 32.70 | 23.10 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_1_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 90827055.30 | 3238.08 | 29-JAN-16:01 | 16.52 | 6.64 | 93719961.90 | 56.69 | 31-JAN-22:19 | 14.13 | 10.68 |
February | 0.244838E+09 | 3347.76 | 28-FEB-16:01 | 23.40 | 12.60 | 85624554.54 | 56.69 | 27-FEB-22:10 | 23.40 | 12.60 |
March | 0.724787E+09 | 3307.98 | 10-MAR-16:01 | 20.10 | 8.83 | 96976365.85 | 56.70 | 30-MAR-21:49 | 22.98 | 16.53 |
April | 0.116443E+10 | 3346.49 | 09-APR-18:01 | 20.45 | 11.08 | 94690908.03 | 56.70 | 17-APR-21:40 | 20.00 | 13.94 |
May | 0.167258E+10 | 3351.05 | 09-MAY-15:01 | 22.80 | 12.60 | 98512108.80 | 56.70 | 30-MAY-21:40 | 22.77 | 21.08 |
June | 0.227947E+10 | 3364.92 | 10-JUN-15:01 | 29.50 | 14.46 | 95749802.94 | 56.70 | 14-JUN-00:10 | 25.60 | 19.62 |
July | 0.257112E+10 | 3256.76 | 09-JUL-15:02 | 33.90 | 23.21 | 98863782.17 | 56.70 | 21-JUL-21:10 | 28.72 | 21.80 |
August | 0.270816E+10 | 3256.08 | 16-AUG-18:02 | 32.12 | 23.27 | 99076253.93 | 56.70 | 18-AUG-21:10 | 30.82 | 22.88 |
September | 0.180749E+10 | 3257.62 | 08-SEP-15:02 | 31.10 | 22.23 | 95286134.94 | 56.70 | 12-SEP-22:10 | 23.22 | 19.83 |
October | 0.944798E+09 | 3354.35 | 12-OCT-15:01 | 20.60 | 11.70 | 97339081.28 | 56.69 | 10-OCT-21:10 | 20.60 | 11.70 |
November | 0.413858E+09 | 3343.01 | 11-NOV-16:01 | 21.32 | 11.45 | 93197802.11 | 56.69 | 01-NOV-21:00 | 21.32 | 11.45 |
December | 0.155507E+09 | 3244.44 | 10-DEC-16:02 | 18.62 | 9.23 | 94510346.53 | 56.69 | 12-DEC-23:10 | 18.22 | 14.85 |
Annual Sum or Average | 0.147779E+11 | 0.114355E+10 | ||||||||
Minimum of Months | 90827055.30 | 3238.08 | 16.52 | 6.64 | 85624554.54 | 56.69 | 14.13 | 10.68 | ||
Maximum of Months | 0.270816E+10 | 3364.92 | 33.90 | 23.27 | 99076253.93 | 56.70 | 30.82 | 22.88 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_2_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 43491659.20 | 1550.10 | 29-JAN-16:01 | 16.52 | 6.64 | 92921909.92 | 56.69 | 03-JAN-22:19 | 16.52 | 6.64 |
February | 0.150078E+09 | 3284.69 | 28-FEB-16:01 | 23.40 | 12.60 | 84954284.89 | 56.69 | 28-FEB-22:00 | 17.30 | 10.02 |
March | 0.539245E+09 | 3254.45 | 26-MAR-18:01 | 19.82 | 9.28 | 96182335.14 | 56.69 | 31-MAR-00:20 | 19.63 | 15.07 |
April | 0.101748E+10 | 3300.46 | 09-APR-18:01 | 20.45 | 11.08 | 94384973.97 | 56.70 | 17-APR-21:10 | 20.00 | 14.08 |
May | 0.160396E+10 | 3308.43 | 09-MAY-15:01 | 22.80 | 12.60 | 98447700.62 | 56.70 | 30-MAY-21:40 | 22.77 | 21.08 |
June | 0.226586E+10 | 3329.91 | 10-JUN-15:01 | 29.50 | 14.46 | 95764262.89 | 56.70 | 20-JUN-22:10 | 20.60 | 19.43 |
July | 0.254041E+10 | 3229.21 | 21-JUL-15:02 | 33.30 | 23.33 | 98873246.55 | 56.70 | 21-JUL-21:10 | 28.72 | 21.80 |
August | 0.257991E+10 | 3211.30 | 19-AUG-15:02 | 33.22 | 24.02 | 99059529.83 | 56.70 | 18-AUG-21:10 | 33.22 | 24.02 |
September | 0.160615E+10 | 3169.33 | 08-SEP-18:02 | 28.80 | 21.95 | 95160979.56 | 56.70 | 08-SEP-22:40 | 24.27 | 21.29 |
October | 0.685403E+09 | 3270.58 | 12-OCT-15:01 | 20.60 | 11.70 | 96572183.81 | 56.69 | 11-OCT-21:40 | 20.60 | 11.70 |
November | 0.246489E+09 | 3262.41 | 11-NOV-16:01 | 21.32 | 11.45 | 92128626.29 | 56.69 | 02-NOV-21:10 | 21.32 | 11.45 |
December | 82697899.09 | 2826.29 | 10-DEC-16:02 | 18.62 | 9.23 | 93420310.67 | 56.69 | 11-DEC-22:10 | 15.60 | 13.95 |
Annual Sum or Average | 0.133612E+11 | 0.113787E+10 | ||||||||
Minimum of Months | 43491659.20 | 1550.10 | 16.52 | 6.64 | 84954284.89 | 56.69 | 15.60 | 6.64 | ||
Maximum of Months | 0.257991E+10 | 3329.91 | 33.30 | 24.02 | 99059529.83 | 56.70 | 33.22 | 24.02 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.183554E+09 | 405.24 | 29-JAN-13:30 | 14.45 | 6.22 | 0.00 | 0.00 | 01-JAN-00:10 | 14.45 | 6.22 |
February | 0.262879E+09 | 532.99 | 26-FEB-14:50 | 24.90 | 12.71 | 0.00 | 0.00 | 01-FEB-00:10 | 24.90 | 12.71 |
March | 0.448949E+09 | 510.15 | 30-MAR-13:40 | 27.43 | 17.97 | 0.00 | 0.00 | 01-MAR-00:10 | 27.43 | 17.97 |
April | 0.520922E+09 | 500.68 | 15-APR-14:00 | 27.80 | 15.01 | 0.00 | 0.00 | 01-APR-00:10 | 27.80 | 15.01 |
May | 0.627405E+09 | 467.38 | 19-MAY-19:20 | 27.40 | 17.96 | 0.00 | 0.00 | 01-MAY-00:10 | 27.40 | 17.96 |
June | 0.784970E+09 | 524.25 | 24-JUN-19:10 | 30.22 | 21.43 | 0.00 | 0.00 | 01-JUN-00:10 | 30.22 | 21.43 |
July | 0.885299E+09 | 565.85 | 08-JUL-19:10 | 31.13 | 23.22 | 0.00 | 0.00 | 01-JUL-00:10 | 31.13 | 23.22 |
August | 0.982119E+09 | 581.04 | 19-AUG-14:00 | 33.90 | 23.86 | 0.00 | 0.00 | 01-AUG-00:10 | 33.90 | 23.86 |
September | 0.774351E+09 | 629.20 | 24-SEP-12:50 | 28.80 | 19.88 | 0.00 | 0.00 | 01-SEP-00:10 | 28.80 | 19.88 |
October | 0.599296E+09 | 661.18 | 10-OCT-13:30 | 28.85 | 20.88 | 0.00 | 0.00 | 01-OCT-00:10 | 28.85 | 20.88 |
November | 0.435661E+09 | 562.74 | 12-NOV-14:00 | 18.90 | 10.54 | 0.00 | 0.00 | 01-NOV-00:10 | 18.90 | 10.54 |
December | 0.299111E+09 | 540.18 | 10-DEC-14:30 | 17.50 | 8.24 | 0.00 | 0.00 | 01-DEC-00:10 | 17.50 | 8.24 |
Annual Sum or Average | 0.680452E+10 | 0.00 | ||||||||
Minimum of Months | 0.183554E+09 | 405.24 | 14.45 | 6.22 | 0.00 | 0.00 | 14.45 | 6.22 | ||
Maximum of Months | 0.982119E+09 | 661.18 | 33.90 | 23.86 | 0.00 | 0.00 | 33.90 | 23.86 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.111544E+09 | 1036.60 | 01-JAN-09:02 | 11.78 | 10.88 | 94335247.86 | 56.69 | 20-JAN-01:10 | 15.50 | 15.03 |
February | 0.211299E+09 | 1167.65 | 28-FEB-19:02 | 21.52 | 12.04 | 85918185.83 | 56.69 | 22-FEB-22:10 | 21.52 | 12.04 |
March | 0.442280E+09 | 1186.16 | 30-MAR-18:02 | 26.02 | 17.62 | 96423003.25 | 56.69 | 30-MAR-21:10 | 23.72 | 16.82 |
April | 0.632896E+09 | 1180.75 | 18-APR-18:02 | 24.13 | 16.72 | 94066847.91 | 56.69 | 03-APR-21:40 | 24.13 | 16.72 |
May | 0.861531E+09 | 1201.21 | 09-MAY-15:01 | 22.80 | 12.60 | 97973069.30 | 56.69 | 23-MAY-21:10 | 21.52 | 16.54 |
June | 0.105865E+10 | 1254.50 | 10-JUN-15:01 | 29.50 | 14.46 | 95468394.49 | 56.70 | 19-JUN-21:49 | 23.68 | 20.36 |
July | 0.115108E+10 | 1191.84 | 16-JUL-18:02 | 32.52 | 22.45 | 98608146.82 | 56.70 | 24-JUL-21:49 | 25.78 | 19.99 |
August | 0.114618E+10 | 1184.33 | 25-AUG-18:02 | 29.82 | 19.04 | 98728622.97 | 56.69 | 21-AUG-21:40 | 29.82 | 19.04 |
September | 0.852231E+09 | 1188.34 | 15-SEP-18:02 | 27.02 | 19.02 | 94738793.02 | 56.69 | 06-SEP-21:30 | 27.02 | 19.02 |
October | 0.539508E+09 | 1158.21 | 02-OCT-18:02 | 24.22 | 19.50 | 96673697.38 | 56.69 | 23-OCT-21:10 | 13.30 | 12.64 |
November | 0.330989E+09 | 1118.52 | 06-NOV-16:01 | 20.32 | 10.34 | 92886160.05 | 56.69 | 03-NOV-21:10 | 20.32 | 10.34 |
December | 0.173154E+09 | 1022.22 | 12-DEC-16:02 | 22.12 | 16.00 | 94991127.50 | 56.69 | 13-DEC-22:10 | 13.22 | 12.84 |
Annual Sum or Average | 0.751135E+10 | 0.114081E+10 | ||||||||
Minimum of Months | 0.111544E+09 | 1022.22 | 11.78 | 10.34 | 85918185.83 | 56.69 | 13.22 | 10.34 | ||
Maximum of Months | 0.115108E+10 | 1254.50 | 32.52 | 22.45 | 98728622.97 | 56.70 | 29.82 | 20.36 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_5_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 84409314.56 | 2795.54 | 29-JAN-16:01 | 16.52 | 6.64 | 93806224.17 | 56.69 | 31-JAN-22:19 | 14.13 | 10.68 |
February | 0.255764E+09 | 3035.45 | 28-FEB-16:01 | 23.40 | 12.60 | 85833243.00 | 56.69 | 28-FEB-22:10 | 18.63 | 10.80 |
March | 0.654836E+09 | 3006.97 | 26-MAR-15:01 | 20.10 | 9.52 | 97239294.90 | 56.69 | 31-MAR-00:20 | 19.63 | 15.07 |
April | 0.112822E+10 | 3034.36 | 09-APR-15:01 | 21.70 | 11.33 | 95001832.85 | 56.69 | 17-APR-21:40 | 20.00 | 13.94 |
May | 0.170447E+10 | 3041.76 | 09-MAY-15:01 | 22.80 | 12.60 | 98797978.26 | 56.70 | 31-MAY-22:10 | 21.73 | 18.83 |
June | 0.231728E+10 | 3062.04 | 10-JUN-15:01 | 29.50 | 14.46 | 95956827.94 | 56.70 | 27-JUN-23:49 | 24.60 | 20.61 |
July | 0.264083E+10 | 2971.86 | 07-JUL-15:02 | 35.10 | 23.86 | 98980276.74 | 56.70 | 14-JUL-21:10 | 28.22 | 21.44 |
August | 0.271818E+10 | 2973.04 | 01-AUG-15:02 | 35.00 | 23.80 | 99163885.91 | 56.70 | 10-AUG-21:10 | 27.23 | 23.67 |
September | 0.181149E+10 | 2925.96 | 07-SEP-15:02 | 31.70 | 23.05 | 95427130.25 | 56.69 | 20-SEP-21:10 | 20.22 | 15.96 |
October | 0.922605E+09 | 3036.19 | 12-OCT-15:01 | 20.60 | 11.70 | 97520098.87 | 56.69 | 09-OCT-23:00 | 20.60 | 11.70 |
November | 0.389699E+09 | 3019.10 | 11-NOV-16:01 | 21.32 | 11.45 | 93373581.09 | 56.69 | 02-NOV-22:19 | 21.32 | 11.45 |
December | 0.149270E+09 | 2862.79 | 10-DEC-16:02 | 18.62 | 9.23 | 94594855.13 | 56.69 | 12-DEC-23:19 | 18.13 | 14.84 |
Annual Sum or Average | 0.147771E+11 | 0.114570E+10 | ||||||||
Minimum of Months | 84409314.56 | 2795.54 | 16.52 | 6.64 | 85833243.00 | 56.69 | 14.13 | 10.68 | ||
Maximum of Months | 0.271818E+10 | 3062.04 | 35.10 | 23.86 | 99163885.91 | 56.70 | 28.22 | 23.67 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_6_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 44349199.48 | 792.56 | 29-JAN-19:03 | 13.12 | 5.32 | 92957351.76 | 56.69 | 05-JAN-22:19 | 13.12 | 5.32 |
February | 0.156602E+09 | 2921.88 | 28-FEB-16:01 | 23.40 | 12.60 | 85116521.17 | 56.69 | 21-FEB-22:49 | 23.40 | 12.60 |
March | 0.466052E+09 | 2842.64 | 27-MAR-15:02 | 21.70 | 13.21 | 96383772.39 | 56.69 | 30-MAR-21:10 | 23.72 | 16.82 |
April | 0.973553E+09 | 2970.48 | 10-APR-15:02 | 25.60 | 14.02 | 94763354.75 | 56.69 | 17-APR-21:10 | 20.00 | 14.08 |
May | 0.163180E+10 | 3009.39 | 09-MAY-15:01 | 22.80 | 12.60 | 98765931.04 | 56.70 | 31-MAY-22:10 | 21.73 | 18.83 |
June | 0.230336E+10 | 3035.66 | 10-JUN-15:01 | 29.50 | 14.46 | 95962024.85 | 56.70 | 13-JUN-21:10 | 28.12 | 21.63 |
July | 0.260971E+10 | 2929.65 | 08-JUL-15:02 | 36.70 | 23.91 | 98979316.45 | 56.70 | 14-JUL-21:10 | 28.22 | 21.44 |
August | 0.258823E+10 | 2906.53 | 19-AUG-15:02 | 33.22 | 24.02 | 99157207.14 | 56.70 | 18-AUG-21:10 | 33.22 | 24.02 |
September | 0.160186E+10 | 2830.94 | 25-SEP-15:02 | 29.40 | 19.56 | 95368048.14 | 56.70 | 15-SEP-21:49 | 29.40 | 19.56 |
October | 0.656695E+09 | 2856.91 | 12-OCT-15:01 | 20.60 | 11.70 | 96817529.43 | 56.69 | 02-OCT-22:10 | 20.60 | 11.70 |
November | 0.221501E+09 | 2668.42 | 06-NOV-16:01 | 20.32 | 10.34 | 92143713.39 | 56.69 | 03-NOV-21:00 | 20.32 | 10.34 |
December | 79200828.13 | 1556.96 | 12-DEC-16:02 | 22.12 | 16.00 | 93443044.99 | 56.69 | 12-DEC-22:19 | 18.30 | 14.70 |
Annual Sum or Average | 0.133329E+11 | 0.113986E+10 | ||||||||
Minimum of Months | 44349199.48 | 792.56 | 13.12 | 5.32 | 85116521.17 | 56.69 | 13.12 | 5.32 | ||
Maximum of Months | 0.260971E+10 | 3035.66 | 36.70 | 24.02 | 99157207.14 | 56.70 | 33.22 | 24.02 |
Report: ZoneCoolingSummaryMonthly
For: CORRIDOR_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.110319E+10 | 1933.19 | 31-JAN-21:45 | 15.28 | 11.27 | 0.119881E+10 | 706.35 | 31-JAN-22:40 | 13.37 | 10.31 |
February | 0.187414E+10 | 2303.48 | 27-FEB-19:10 | 19.82 | 10.52 | 0.108485E+10 | 729.36 | 28-FEB-22:40 | 17.83 | 10.34 |
March | 0.384164E+10 | 2643.53 | 11-MAR-19:01 | 23.12 | 14.94 | 0.121104E+10 | 753.71 | 30-MAR-21:49 | 22.98 | 16.53 |
April | 0.459637E+10 | 2761.55 | 19-APR-18:02 | 24.63 | 15.68 | 0.118145E+10 | 755.41 | 17-APR-22:10 | 24.63 | 15.68 |
May | 0.547843E+10 | 2769.11 | 20-MAY-10:35 | 27.23 | 18.94 | 0.124449E+10 | 774.79 | 19-MAY-21:40 | 27.23 | 18.94 |
June | 0.590750E+10 | 2998.77 | 07-JUN-18:03 | 23.12 | 13.70 | 0.126746E+10 | 805.77 | 29-JUN-21:49 | 25.18 | 21.75 |
July | 0.633294E+10 | 3112.96 | 08-JUL-10:35 | 33.17 | 24.62 | 0.133041E+10 | 822.30 | 07-JUL-22:10 | 33.17 | 24.62 |
August | 0.640004E+10 | 3124.99 | 19-AUG-10:35 | 32.03 | 24.19 | 0.134690E+10 | 830.37 | 18-AUG-21:00 | 32.03 | 24.19 |
September | 0.555391E+10 | 2932.82 | 09-SEP-10:35 | 30.03 | 23.84 | 0.123598E+10 | 799.55 | 08-SEP-21:49 | 30.03 | 23.84 |
October | 0.438741E+10 | 2985.87 | 11-OCT-17:10 | 24.03 | 13.79 | 0.121483E+10 | 757.32 | 10-OCT-21:49 | 24.03 | 13.79 |
November | 0.314449E+10 | 2173.47 | 02-NOV-18:50 | 18.98 | 15.19 | 0.116077E+10 | 719.16 | 02-NOV-21:40 | 16.47 | 14.23 |
December | 0.186539E+10 | 2073.47 | 12-DEC-21:00 | 18.30 | 14.62 | 0.119909E+10 | 719.88 | 12-DEC-23:10 | 18.22 | 14.85 |
Annual Sum or Average | 0.504855E+11 | 0.146761E+11 | ||||||||
Minimum of Months | 0.110319E+10 | 1933.19 | 15.28 | 10.52 | 0.108485E+10 | 706.35 | 13.37 | 10.31 | ||
Maximum of Months | 0.640004E+10 | 3124.99 | 33.17 | 24.62 | 0.134690E+10 | 830.37 | 33.17 | 24.62 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_1_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 65745151.22 | 3428.34 | 29-JAN-16:01 | 16.52 | 6.64 | 93250955.19 | 56.69 | 31-JAN-22:19 | 14.13 | 10.68 |
February | 0.223614E+09 | 3564.95 | 28-FEB-16:01 | 23.40 | 12.60 | 85317877.49 | 56.69 | 27-FEB-22:00 | 23.40 | 12.60 |
March | 0.727953E+09 | 3526.39 | 10-MAR-16:01 | 20.10 | 8.83 | 96782199.99 | 56.70 | 30-MAR-21:49 | 22.98 | 16.53 |
April | 0.125801E+10 | 3573.84 | 09-APR-15:01 | 21.70 | 11.33 | 94666275.45 | 56.70 | 17-APR-21:49 | 20.00 | 13.89 |
May | 0.188419E+10 | 3577.41 | 09-MAY-15:01 | 22.80 | 12.60 | 98558163.31 | 56.70 | 15-MAY-02:49 | 12.88 | 11.22 |
June | 0.256217E+10 | 3597.06 | 10-JUN-15:01 | 29.50 | 14.46 | 95769150.60 | 56.70 | 20-JUN-21:00 | 20.60 | 19.43 |
July | 0.289538E+10 | 3469.59 | 05-JUL-18:02 | 31.52 | 22.95 | 98888463.41 | 56.70 | 07-JUL-21:30 | 30.00 | 22.76 |
August | 0.303299E+10 | 3478.77 | 17-AUG-18:02 | 32.02 | 23.76 | 99088105.58 | 56.70 | 18-AUG-21:30 | 30.25 | 22.97 |
September | 0.197059E+10 | 3414.61 | 08-SEP-18:02 | 28.80 | 21.95 | 95284850.63 | 56.70 | 07-SEP-22:00 | 28.80 | 21.95 |
October | 0.975557E+09 | 3571.76 | 12-OCT-15:01 | 20.60 | 11.70 | 97187853.93 | 56.70 | 08-OCT-02:39 | 20.60 | 11.70 |
November | 0.381778E+09 | 3559.21 | 11-NOV-16:01 | 21.32 | 11.45 | 92889727.14 | 56.69 | 04-NOV-03:30 | 21.32 | 11.45 |
December | 0.127239E+09 | 3443.74 | 10-DEC-16:02 | 18.62 | 9.23 | 93958956.64 | 56.69 | 12-DEC-23:10 | 18.22 | 14.85 |
Annual Sum or Average | 0.161052E+11 | 0.114164E+10 | ||||||||
Minimum of Months | 65745151.22 | 3414.61 | 16.52 | 6.64 | 85317877.49 | 56.69 | 12.88 | 10.68 | ||
Maximum of Months | 0.303299E+10 | 3597.06 | 32.02 | 23.76 | 99088105.58 | 56.70 | 30.25 | 22.97 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_2_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 27666583.17 | 776.93 | 28-JAN-16:03 | 12.20 | 4.56 | 92682768.40 | 56.69 | 09-JAN-22:19 | 12.20 | 4.56 |
February | 0.133765E+09 | 3491.65 | 28-FEB-16:01 | 23.40 | 12.60 | 84748412.55 | 56.69 | 28-FEB-22:40 | 17.83 | 10.34 |
March | 0.534618E+09 | 3456.92 | 26-MAR-18:01 | 19.82 | 9.28 | 95999845.17 | 56.70 | 29-MAR-21:10 | 22.62 | 17.00 |
April | 0.109865E+10 | 3518.46 | 09-APR-18:01 | 20.45 | 11.08 | 94410307.57 | 56.70 | 14-APR-21:10 | 19.53 | 13.39 |
May | 0.180756E+10 | 3528.00 | 09-MAY-15:01 | 22.80 | 12.60 | 98523960.22 | 56.70 | 23-MAY-21:10 | 21.52 | 16.54 |
June | 0.254693E+10 | 3555.92 | 10-JUN-15:01 | 29.50 | 14.46 | 95785704.09 | 56.70 | 21-JUN-21:10 | 26.52 | 20.84 |
July | 0.286308E+10 | 3429.31 | 05-JUL-18:02 | 31.52 | 22.95 | 98898628.77 | 56.70 | 06-JUL-21:10 | 28.22 | 23.31 |
August | 0.289762E+10 | 3425.59 | 06-AUG-15:02 | 31.88 | 23.78 | 99075663.68 | 56.70 | 30-AUG-21:00 | 22.80 | 20.81 |
September | 0.175157E+10 | 3414.65 | 08-SEP-15:02 | 31.10 | 22.23 | 95194337.15 | 56.70 | 15-SEP-21:30 | 24.45 | 17.91 |
October | 0.702643E+09 | 3474.16 | 12-OCT-15:01 | 20.60 | 11.70 | 96463194.73 | 56.69 | 02-OCT-22:10 | 20.60 | 11.70 |
November | 0.219204E+09 | 3460.45 | 11-NOV-16:01 | 21.32 | 11.45 | 91804908.49 | 56.69 | 28-NOV-01:10 | 18.03 | 17.16 |
December | 62587116.07 | 2817.96 | 11-DEC-16:02 | 21.02 | 15.88 | 92987286.79 | 56.69 | 12-DEC-22:19 | 18.30 | 14.70 |
Annual Sum or Average | 0.146459E+11 | 0.113658E+10 | ||||||||
Minimum of Months | 27666583.17 | 776.93 | 12.20 | 4.56 | 84748412.55 | 56.69 | 12.20 | 4.56 | ||
Maximum of Months | 0.289762E+10 | 3555.92 | 31.88 | 23.78 | 99075663.68 | 56.70 | 28.22 | 23.31 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.176072E+09 | 1847.32 | 29-JAN-16:01 | 16.52 | 6.64 | 95427340.19 | 56.69 | 31-JAN-22:19 | 14.13 | 10.68 |
February | 0.306236E+09 | 1897.19 | 21-FEB-16:01 | 22.12 | 10.94 | 86766362.92 | 56.69 | 27-FEB-22:10 | 15.40 | 8.51 |
March | 0.654003E+09 | 1895.14 | 13-MAR-15:02 | 23.98 | 13.14 | 97547643.92 | 56.70 | 30-MAR-21:10 | 23.72 | 16.82 |
April | 0.842225E+09 | 1891.69 | 09-APR-15:01 | 21.70 | 11.33 | 94880654.28 | 56.70 | 19-APR-21:49 | 17.98 | 15.78 |
May | 0.111005E+10 | 1867.67 | 10-MAY-15:01 | 21.78 | 12.62 | 98545748.29 | 56.70 | 23-MAY-21:00 | 20.60 | 17.08 |
June | 0.142547E+10 | 1864.02 | 10-JUN-18:02 | 28.62 | 13.87 | 95738689.31 | 56.70 | 27-JUN-21:10 | 27.02 | 21.02 |
July | 0.162936E+10 | 1834.07 | 15-JUL-15:02 | 32.88 | 24.22 | 98861637.14 | 56.70 | 14-JUL-21:30 | 32.88 | 24.22 |
August | 0.178881E+10 | 1822.27 | 06-AUG-15:02 | 31.88 | 23.78 | 99076120.59 | 56.70 | 25-AUG-21:10 | 26.02 | 18.49 |
September | 0.133354E+10 | 1818.58 | 25-SEP-15:02 | 29.40 | 19.56 | 95378613.59 | 56.70 | 08-SEP-21:10 | 29.40 | 19.56 |
October | 0.917990E+09 | 1896.06 | 13-OCT-15:02 | 21.78 | 12.23 | 97859281.18 | 56.69 | 16-OCT-22:10 | 20.00 | 17.37 |
November | 0.577773E+09 | 1902.17 | 11-NOV-16:01 | 21.32 | 11.45 | 94334612.39 | 56.69 | 02-NOV-22:00 | 21.32 | 11.45 |
December | 0.309951E+09 | 1865.55 | 10-DEC-16:02 | 18.62 | 9.23 | 96165283.17 | 56.69 | 13-DEC-00:49 | 16.88 | 14.41 |
Annual Sum or Average | 0.110715E+11 | 0.115058E+10 | ||||||||
Minimum of Months | 0.176072E+09 | 1818.58 | 16.52 | 6.64 | 86766362.92 | 56.69 | 14.13 | 8.51 | ||
Maximum of Months | 0.178881E+10 | 1902.17 | 32.88 | 24.22 | 99076120.59 | 56.70 | 32.88 | 24.22 |
Report: ZoneCoolingSummaryMonthly
For: BANQUET_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.353755E+11 | 19602.47 | 19-JAN-23:00 | 18.30 | 16.51 | 0.147963E+11 | 10054.12 | 31-JAN-22:00 | 12.60 | 9.92 |
February | 0.341665E+11 | 19830.90 | 28-FEB-23:00 | 17.30 | 10.02 | 0.135795E+11 | 10175.20 | 28-FEB-23:10 | 17.02 | 9.75 |
March | 0.419871E+11 | 22417.35 | 11-MAR-19:01 | 23.12 | 14.94 | 0.154816E+11 | 10420.38 | 30-MAR-22:10 | 22.62 | 16.35 |
April | 0.431663E+11 | 23015.69 | 07-APR-18:10 | 23.43 | 13.72 | 0.151116E+11 | 10379.58 | 18-APR-22:10 | 19.32 | 14.41 |
May | 0.472247E+11 | 24194.37 | 15-MAY-18:56 | 27.20 | 15.84 | 0.159062E+11 | 10649.84 | 17-MAY-21:19 | 23.90 | 16.97 |
June | 0.481029E+11 | 24138.41 | 07-JUN-18:03 | 23.12 | 13.70 | 0.157223E+11 | 10777.15 | 13-JUN-22:10 | 27.12 | 20.92 |
July | 0.504738E+11 | 23913.69 | 13-JUL-18:10 | 32.70 | 22.67 | 0.162452E+11 | 10896.90 | 07-JUL-22:10 | 32.70 | 22.67 |
August | 0.505088E+11 | 23846.06 | 02-AUG-18:10 | 32.80 | 23.11 | 0.163663E+11 | 10845.61 | 18-AUG-22:10 | 29.32 | 23.10 |
September | 0.455986E+11 | 22738.52 | 07-SEP-18:10 | 29.72 | 22.85 | 0.153907E+11 | 10591.55 | 06-SEP-22:10 | 29.72 | 22.85 |
October | 0.429755E+11 | 23314.20 | 11-OCT-17:10 | 24.03 | 13.79 | 0.154627E+11 | 10399.77 | 18-OCT-22:10 | 22.80 | 22.03 |
November | 0.389204E+11 | 19935.41 | 03-NOV-22:00 | 17.80 | 16.05 | 0.147051E+11 | 10146.79 | 03-NOV-22:10 | 17.80 | 16.05 |
December | 0.375071E+11 | 19771.22 | 12-DEC-23:00 | 18.30 | 14.87 | 0.149574E+11 | 10209.96 | 13-DEC-22:49 | 12.88 | 12.51 |
Annual Sum or Average | 0.516007E+12 | 0.183725E+12 | ||||||||
Minimum of Months | 0.341665E+11 | 19602.47 | 17.30 | 10.02 | 0.135795E+11 | 10054.12 | 12.60 | 9.75 | ||
Maximum of Months | 0.505088E+11 | 24194.37 | 32.80 | 23.11 | 0.163663E+11 | 10896.90 | 32.70 | 23.10 |
Report: ZoneCoolingSummaryMonthly
For: DINING_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.383097E+11 | 20847.12 | 19-JAN-23:00 | 18.30 | 16.51 | 0.148692E+11 | 10153.22 | 31-JAN-22:00 | 12.60 | 9.92 |
February | 0.368831E+11 | 21085.71 | 28-FEB-23:00 | 17.30 | 10.02 | 0.136561E+11 | 10274.46 | 28-FEB-23:10 | 17.02 | 9.75 |
March | 0.451022E+11 | 23856.52 | 11-MAR-19:01 | 23.12 | 14.94 | 0.155854E+11 | 10517.54 | 30-MAR-22:10 | 22.62 | 16.35 |
April | 0.462419E+11 | 24466.92 | 07-APR-18:10 | 23.43 | 13.72 | 0.152261E+11 | 10481.00 | 18-APR-22:10 | 19.32 | 14.41 |
May | 0.504672E+11 | 25669.77 | 15-MAY-18:56 | 27.20 | 15.84 | 0.160371E+11 | 10753.89 | 17-MAY-21:19 | 23.90 | 16.97 |
June | 0.512429E+11 | 25698.85 | 07-JUN-18:03 | 23.12 | 13.70 | 0.158473E+11 | 10861.71 | 13-JUN-22:10 | 27.12 | 20.92 |
July | 0.536612E+11 | 25281.61 | 13-JUL-18:10 | 32.70 | 22.67 | 0.163576E+11 | 10963.05 | 07-JUL-22:10 | 32.70 | 22.67 |
August | 0.536742E+11 | 25202.07 | 02-AUG-18:10 | 32.80 | 23.11 | 0.164733E+11 | 10909.18 | 18-AUG-22:10 | 29.32 | 23.10 |
September | 0.487089E+11 | 24086.26 | 07-SEP-18:10 | 29.72 | 22.85 | 0.155096E+11 | 10690.45 | 05-SEP-22:10 | 29.72 | 22.85 |
October | 0.460898E+11 | 24750.80 | 11-OCT-17:10 | 24.03 | 13.79 | 0.155674E+11 | 10501.05 | 18-OCT-22:10 | 22.80 | 22.03 |
November | 0.418621E+11 | 21199.31 | 03-NOV-22:00 | 17.80 | 16.05 | 0.147936E+11 | 10246.37 | 03-NOV-22:10 | 17.80 | 16.05 |
December | 0.404808E+11 | 21008.20 | 12-DEC-23:00 | 18.30 | 14.87 | 0.150394E+11 | 10310.57 | 13-DEC-22:49 | 12.88 | 12.51 |
Annual Sum or Average | 0.552724E+12 | 0.184962E+12 | ||||||||
Minimum of Months | 0.368831E+11 | 20847.12 | 17.30 | 10.02 | 0.136561E+11 | 10153.22 | 12.60 | 9.75 | ||
Maximum of Months | 0.536742E+11 | 25698.85 | 32.80 | 23.11 | 0.164733E+11 | 10963.05 | 32.70 | 23.10 |
Report: ZoneCoolingSummaryMonthly
For: KITCHEN_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.485246E+11 | 26130.53 | 31-JAN-11:50 | 16.73 | 13.07 | 0.186008E+11 | 11319.47 | 28-JAN-18:30 | 16.73 | 13.07 |
February | 0.455693E+11 | 27617.50 | 26-FEB-11:50 | 22.43 | 11.86 | 0.168178E+11 | 11319.53 | 25-FEB-18:19 | 22.43 | 11.86 |
March | 0.536762E+11 | 30232.80 | 11-MAR-19:01 | 23.12 | 14.94 | 0.186520E+11 | 11361.96 | 11-MAR-18:00 | 23.12 | 14.94 |
April | 0.540146E+11 | 30023.66 | 19-APR-18:02 | 24.63 | 15.68 | 0.180586E+11 | 11334.02 | 08-APR-17:00 | 24.63 | 15.68 |
May | 0.579091E+11 | 31049.17 | 13-MAY-10:50 | 23.12 | 13.77 | 0.186750E+11 | 11319.75 | 13-MAY-17:19 | 25.93 | 14.23 |
June | 0.578584E+11 | 31815.65 | 07-JUN-18:03 | 23.12 | 13.70 | 0.180858E+11 | 11319.74 | 10-JUN-17:19 | 29.23 | 13.92 |
July | 0.603866E+11 | 31122.70 | 08-JUL-10:50 | 33.53 | 24.57 | 0.186858E+11 | 11319.73 | 15-JUL-17:19 | 33.30 | 24.04 |
August | 0.604955E+11 | 30830.55 | 19-AUG-10:50 | 32.12 | 24.17 | 0.186936E+11 | 11319.73 | 26-AUG-17:19 | 30.60 | 20.54 |
September | 0.561412E+11 | 30245.12 | 09-SEP-10:50 | 30.32 | 23.97 | 0.180724E+11 | 11319.74 | 23-SEP-17:19 | 27.23 | 18.81 |
October | 0.547110E+11 | 31547.43 | 11-OCT-17:10 | 24.03 | 13.79 | 0.186514E+11 | 11331.24 | 07-OCT-17:10 | 24.03 | 13.79 |
November | 0.506093E+11 | 27196.46 | 11-NOV-11:40 | 18.50 | 11.57 | 0.180334E+11 | 11319.95 | 25-NOV-18:00 | 12.80 | 7.45 |
December | 0.501050E+11 | 26763.80 | 12-DEC-11:50 | 20.22 | 16.28 | 0.186162E+11 | 11319.55 | 09-DEC-18:19 | 20.22 | 16.28 |
Annual Sum or Average | 0.650001E+12 | 0.219643E+12 | ||||||||
Minimum of Months | 0.455693E+11 | 26130.53 | 16.73 | 11.57 | 0.168178E+11 | 11319.47 | 12.80 | 7.45 | ||
Maximum of Months | 0.604955E+11 | 31815.65 | 33.53 | 24.57 | 0.186936E+11 | 11361.96 | 33.30 | 24.04 |
Report: ZoneCoolingSummaryMonthly
For: CORRIDOR_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.955437E+09 | 2991.11 | 31-JAN-21:10 | 16.82 | 12.20 | 0.126769E+10 | 745.72 | 26-JAN-03:30 | 16.82 | 12.20 |
February | 0.245584E+10 | 5056.75 | 27-FEB-16:30 | 22.50 | 11.38 | 0.114550E+10 | 745.84 | 01-FEB-00:00 | 22.50 | 11.38 |
March | 0.596138E+10 | 6044.28 | 30-MAR-17:12 | 26.50 | 17.73 | 0.127520E+10 | 765.27 | 30-MAR-21:40 | 23.17 | 16.60 |
April | 0.818089E+10 | 6506.09 | 19-APR-18:02 | 24.63 | 15.68 | 0.123292E+10 | 764.72 | 17-APR-21:40 | 24.63 | 15.68 |
May | 0.110819E+11 | 6606.60 | 15-MAY-18:56 | 27.20 | 15.84 | 0.128080E+10 | 786.31 | 19-MAY-21:40 | 22.77 | 15.87 |
June | 0.129971E+11 | 7033.96 | 13-JUN-17:12 | 32.60 | 22.18 | 0.126760E+10 | 819.20 | 13-JUN-21:49 | 27.38 | 21.12 |
July | 0.141269E+11 | 7635.77 | 08-JUL-17:13 | 34.40 | 23.36 | 0.132751E+10 | 847.04 | 07-JUL-22:10 | 34.40 | 23.36 |
August | 0.144498E+11 | 7421.39 | 19-AUG-10:35 | 32.03 | 24.19 | 0.133811E+10 | 845.00 | 18-AUG-21:49 | 32.03 | 24.19 |
September | 0.110749E+11 | 6808.04 | 09-SEP-10:35 | 30.03 | 23.84 | 0.124157E+10 | 798.69 | 07-SEP-21:40 | 30.03 | 23.84 |
October | 0.728296E+10 | 7060.73 | 11-OCT-17:10 | 24.03 | 13.79 | 0.127072E+10 | 760.95 | 10-OCT-21:40 | 24.03 | 13.79 |
November | 0.427859E+10 | 4972.03 | 05-NOV-15:30 | 24.15 | 18.21 | 0.122733E+10 | 745.83 | 20-NOV-03:09 | 12.93 | 10.29 |
December | 0.188867E+10 | 4057.28 | 12-DEC-14:00 | 22.80 | 17.07 | 0.126876E+10 | 745.79 | 01-DEC-01:49 | 22.80 | 17.07 |
Annual Sum or Average | 0.947344E+11 | 0.151437E+11 | ||||||||
Minimum of Months | 0.955437E+09 | 2991.11 | 16.82 | 11.38 | 0.114550E+10 | 745.72 | 12.93 | 10.29 | ||
Maximum of Months | 0.144498E+11 | 7635.77 | 34.40 | 24.19 | 0.133811E+10 | 847.04 | 34.40 | 24.19 |
Report: ZoneHeatingSummaryMonthly
For: BASEMENT
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 5.70 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 9.92 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 15.32 |
April | 0.00 | 0.00 | 01-APR-00:10 | 12.05 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 9.70 |
December | 0.00 | 0.00 | 01-DEC-00:05 | 1.80 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 1.80 | |
Maximum of Months | 0.00 | 0.00 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: RETAIL_1_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.819632E+09 | 1391.27 | 08-JAN-05:30 | -5.3 |
February | 0.430733E+09 | 1592.05 | 12-FEB-07:00 | -12.8 |
March | 35419482.15 | 507.07 | 18-MAR-06:50 | 2.30 |
April | 17418360.74 | 553.90 | 06-APR-06:10 | 1.20 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
October | 11900398.11 | 415.91 | 26-OCT-06:50 | 2.20 |
November | 85867267.55 | 1073.10 | 21-NOV-07:10 | -2.8 |
December | 0.315077E+09 | 1151.92 | 18-DEC-07:40 | -5.4 |
Annual Sum or Average | 0.171605E+10 | |||
Minimum of Months | 0.00 | 0.00 | -12.8 | |
Maximum of Months | 0.819632E+09 | 1592.05 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: RETAIL_2_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 5.70 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 9.92 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 15.32 |
April | 0.00 | 0.00 | 01-APR-00:10 | 12.05 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 9.70 |
December | 0.00 | 0.00 | 01-DEC-00:05 | 1.80 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 1.80 | |
Maximum of Months | 0.00 | 0.00 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: MECH_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.333900E+09 | 568.61 | 08-JAN-06:00 | -5.0 |
February | 0.185472E+09 | 596.29 | 12-FEB-06:00 | -12.2 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 15.32 |
April | 0.00 | 0.00 | 01-APR-00:10 | 12.05 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 |
November | 7764511.30 | 324.82 | 22-NOV-05:00 | -2.8 |
December | 61252854.78 | 495.39 | 18-DEC-05:00 | -5.0 |
Annual Sum or Average | 0.588389E+09 | |||
Minimum of Months | 0.00 | 0.00 | -12.2 | |
Maximum of Months | 0.333900E+09 | 596.29 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: STORAGE_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.457757E+09 | 437.72 | 08-JAN-06:00 | -5.0 |
February | 0.250491E+09 | 460.44 | 12-FEB-07:00 | -12.8 |
March | 9035301.90 | 143.96 | 19-MAR-04:50 | 2.12 |
April | 1983378.76 | 72.14 | 06-APR-05:00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
October | 1261867.10 | 70.94 | 26-OCT-07:12 | 2.93 |
November | 33224535.02 | 293.00 | 22-NOV-04:50 | -2.8 |
December | 0.164487E+09 | 393.74 | 18-DEC-05:00 | -5.0 |
Annual Sum or Average | 0.918240E+09 | |||
Minimum of Months | 0.00 | 0.00 | -12.8 | |
Maximum of Months | 0.457757E+09 | 460.44 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: LAUNDRY_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 5.70 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 9.92 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 15.32 |
April | 0.00 | 0.00 | 01-APR-00:10 | 12.05 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 9.70 |
December | 0.00 | 0.00 | 01-DEC-00:05 | 1.80 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 1.80 | |
Maximum of Months | 0.00 | 0.00 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: CAFE_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 8993578.26 | 980.71 | 09-JAN-09:10 | -3.2 |
February | 167729.13 | 60.94 | 06-FEB-10:20 | 0.77 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 15.32 |
April | 0.00 | 0.00 | 01-APR-00:10 | 12.05 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 9.70 |
December | 0.00 | 0.00 | 01-DEC-00:05 | 1.80 |
Annual Sum or Average | 9161307.39 | |||
Minimum of Months | 0.00 | 0.00 | -3.2 | |
Maximum of Months | 8993578.26 | 980.71 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: LOBBY_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 5.70 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 9.92 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 15.32 |
April | 0.00 | 0.00 | 01-APR-00:10 | 12.05 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 9.70 |
December | 0.00 | 0.00 | 01-DEC-00:05 | 1.80 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 1.80 | |
Maximum of Months | 0.00 | 0.00 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_1_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.111800E+10 | 1940.01 | 07-JAN-19:02 | -5.6 |
February | 0.654234E+09 | 1945.88 | 12-FEB-09:02 | -10.2 |
March | 0.130968E+09 | 1863.74 | 23-MAR-08:62 | 6.97 |
April | 41271444.21 | 1853.69 | 06-APR-08:62 | 5.37 |
May | 1062962.50 | 611.99 | 05-MAY-08:03 | 19.87 |
June | 1068109.06 | 702.71 | 06-JUN-08:04 | 24.27 |
July | 906305.03 | 531.96 | 02-JUL-08:05 | 22.67 |
August | 926103.52 | 754.31 | 26-AUG-08:04 | 23.07 |
September | 1568229.21 | 583.78 | 15-SEP-08:03 | 19.37 |
October | 75307845.38 | 1855.40 | 30-OCT-15:01 | 11.60 |
November | 0.253418E+09 | 1886.55 | 22-NOV-09:02 | 1.05 |
December | 0.678121E+09 | 1899.46 | 18-DEC-09:02 | -1.7 |
Annual Sum or Average | 0.295685E+10 | |||
Minimum of Months | 906305.03 | 531.96 | -10.2 | |
Maximum of Months | 0.111800E+10 | 1945.88 | 24.27 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_2_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.139443E+10 | 1939.33 | 07-JAN-19:02 | -5.6 |
February | 0.824633E+09 | 1962.66 | 12-FEB-09:02 | -10.2 |
March | 0.181221E+09 | 1862.22 | 23-MAR-08:62 | 6.97 |
April | 50639012.80 | 1858.24 | 06-APR-08:62 | 5.37 |
May | 1383353.92 | 609.21 | 05-MAY-08:03 | 19.87 |
June | 1087247.53 | 839.94 | 04-JUN-08:04 | 22.57 |
July | 766935.01 | 624.77 | 02-JUL-08:05 | 22.67 |
August | 947236.54 | 926.77 | 26-AUG-08:04 | 23.07 |
September | 1738027.22 | 642.48 | 23-SEP-08:03 | 20.37 |
October | 0.105298E+09 | 1873.40 | 26-OCT-08:62 | 5.05 |
November | 0.372929E+09 | 1908.32 | 21-NOV-09:02 | -0.1 |
December | 0.901250E+09 | 1921.79 | 18-DEC-09:02 | -1.7 |
Annual Sum or Average | 0.383633E+10 | |||
Minimum of Months | 766935.01 | 609.21 | -10.2 | |
Maximum of Months | 0.139443E+10 | 1962.66 | 23.07 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 32176737.34 | 263.44 | 08-JAN-05:10 | -5.5 |
February | 7864996.25 | 266.59 | 12-FEB-06:00 | -12.2 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 15.32 |
April | 0.00 | 0.00 | 01-APR-00:10 | 12.05 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 9.70 |
December | 0.00 | 0.00 | 01-DEC-00:05 | 1.80 |
Annual Sum or Average | 40041733.59 | |||
Minimum of Months | 0.00 | 0.00 | -12.2 | |
Maximum of Months | 32176737.34 | 266.59 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.159245E+09 | 599.19 | 27-JAN-16:01 | 4.40 |
February | 89410773.84 | 598.27 | 03-FEB-16:02 | 1.60 |
March | 2044846.40 | 552.61 | 22-MAR-15:02 | 5.10 |
April | 866253.89 | 434.03 | 26-APR-15:04 | 15.68 |
May | 240929.60 | 256.95 | 10-MAY-08:04 | 11.57 |
June | 82728.03 | 235.04 | 02-JUN-08:05 | 22.48 |
July | 47378.94 | 178.28 | 11-JUL-08:06 | 24.68 |
August | 37007.37 | 197.82 | 25-AUG-08:05 | 22.15 |
September | 331292.15 | 296.51 | 23-SEP-08:05 | 20.37 |
October | 1132608.40 | 552.16 | 26-OCT-08:62 | 5.05 |
November | 12177755.37 | 571.53 | 22-NOV-16:01 | 12.02 |
December | 51794945.35 | 582.14 | 02-DEC-16:01 | 5.82 |
Annual Sum or Average | 0.317412E+09 | |||
Minimum of Months | 37007.37 | 178.28 | 1.60 | |
Maximum of Months | 0.159245E+09 | 599.19 | 24.68 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_5_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.112367E+10 | 1875.33 | 07-JAN-19:02 | -5.6 |
February | 0.643152E+09 | 1856.91 | 11-FEB-19:02 | -6.2 |
March | 0.134170E+09 | 1800.20 | 23-MAR-08:62 | 6.97 |
April | 41523383.69 | 837.80 | 06-APR-18:03 | 14.63 |
May | 1407775.01 | 685.41 | 10-MAY-15:04 | 21.78 |
June | 86889.72 | 421.99 | 18-JUN-08:05 | 20.78 |
July | 244280.77 | 472.81 | 30-JUL-08:05 | 22.48 |
August | 127332.40 | 473.83 | 24-AUG-08:05 | 23.80 |
September | 989773.03 | 559.12 | 17-SEP-08:05 | 23.58 |
October | 77465625.55 | 1795.77 | 30-OCT-15:01 | 11.60 |
November | 0.247866E+09 | 1819.59 | 30-NOV-16:02 | 7.20 |
December | 0.663742E+09 | 1826.11 | 25-DEC-16:02 | 6.02 |
Annual Sum or Average | 0.293444E+10 | |||
Minimum of Months | 86889.72 | 421.99 | -6.2 | |
Maximum of Months | 0.112367E+10 | 1875.33 | 23.80 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_6_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.140362E+10 | 1875.43 | 07-JAN-19:02 | -5.6 |
February | 0.804444E+09 | 1858.96 | 11-FEB-19:02 | -6.2 |
March | 0.177958E+09 | 1804.85 | 22-MAR-15:02 | 5.10 |
April | 50782493.21 | 885.70 | 04-APR-18:04 | 24.90 |
May | 1845221.73 | 530.88 | 10-MAY-15:04 | 21.78 |
June | 67877.41 | 431.72 | 18-JUN-08:05 | 20.78 |
July | 238658.90 | 479.88 | 30-JUL-08:05 | 22.48 |
August | 123720.25 | 469.49 | 24-AUG-08:05 | 23.80 |
September | 1397023.94 | 563.07 | 17-SEP-08:05 | 23.58 |
October | 0.108072E+09 | 1796.46 | 30-OCT-15:01 | 11.60 |
November | 0.356114E+09 | 1824.36 | 22-NOV-16:01 | 12.02 |
December | 0.884423E+09 | 1854.25 | 17-DEC-16:01 | 4.22 |
Annual Sum or Average | 0.378908E+10 | |||
Minimum of Months | 67877.41 | 431.72 | -6.2 | |
Maximum of Months | 0.140362E+10 | 1875.43 | 24.90 |
Report: ZoneHeatingSummaryMonthly
For: CORRIDOR_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.263377E+09 | 958.65 | 07-JAN-17:00 | -5.0 |
February | 0.132434E+09 | 939.17 | 12-FEB-08:10 | -11.9 |
March | 1019641.16 | 96.19 | 22-MAR-11:30 | 4.40 |
April | 0.00 | 0.00 | 01-APR-00:10 | 12.05 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 |
November | 3213416.11 | 350.44 | 22-NOV-07:10 | -3.2 |
December | 29567019.14 | 511.16 | 18-DEC-07:40 | -5.4 |
Annual Sum or Average | 0.429611E+09 | |||
Minimum of Months | 0.00 | 0.00 | -11.9 | |
Maximum of Months | 0.263377E+09 | 958.65 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_1_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.165388E+10 | 2295.69 | 07-JAN-16:13 | -4.3 |
February | 0.994010E+09 | 2301.04 | 12-FEB-09:02 | -10.2 |
March | 0.246356E+09 | 2198.06 | 23-MAR-08:62 | 6.97 |
April | 78062634.75 | 2195.32 | 06-APR-08:62 | 5.37 |
May | 3232436.46 | 895.41 | 14-MAY-08:03 | 16.15 |
June | 960455.79 | 716.40 | 06-JUN-08:04 | 24.27 |
July | 722151.46 | 614.99 | 11-JUL-08:04 | 24.68 |
August | 794759.56 | 789.41 | 26-AUG-08:04 | 23.07 |
September | 3360585.33 | 759.54 | 23-SEP-08:03 | 20.37 |
October | 0.151029E+09 | 2201.15 | 30-OCT-15:01 | 11.60 |
November | 0.442024E+09 | 2220.10 | 21-NOV-09:02 | -0.1 |
December | 0.107139E+10 | 2235.38 | 18-DEC-09:02 | -1.7 |
Annual Sum or Average | 0.464582E+10 | |||
Minimum of Months | 722151.46 | 614.99 | -10.2 | |
Maximum of Months | 0.165388E+10 | 2301.04 | 24.68 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_2_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.199857E+10 | 2298.23 | 07-JAN-16:13 | -4.3 |
February | 0.120727E+10 | 2325.51 | 12-FEB-09:13 | -9.8 |
March | 0.318858E+09 | 2198.92 | 19-MAR-08:62 | 4.27 |
April | 92633309.74 | 2196.35 | 06-APR-08:62 | 5.37 |
May | 3918734.66 | 901.44 | 14-MAY-08:03 | 16.15 |
June | 948630.29 | 753.71 | 06-JUN-08:04 | 24.27 |
July | 634250.59 | 549.10 | 02-JUL-08:05 | 22.67 |
August | 822380.07 | 862.33 | 26-AUG-08:04 | 23.07 |
September | 3767652.85 | 826.94 | 10-SEP-08:04 | 22.97 |
October | 0.202588E+09 | 2206.77 | 26-OCT-08:62 | 5.05 |
November | 0.611523E+09 | 2242.06 | 22-NOV-09:02 | 1.05 |
December | 0.135832E+10 | 2265.10 | 18-DEC-09:02 | -1.7 |
Annual Sum or Average | 0.579986E+10 | |||
Minimum of Months | 634250.59 | 549.10 | -9.8 | |
Maximum of Months | 0.199857E+10 | 2325.51 | 24.27 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.480149E+09 | 1188.27 | 07-JAN-16:13 | -4.3 |
February | 0.272979E+09 | 1173.47 | 12-FEB-09:02 | -10.2 |
March | 48497186.38 | 1134.10 | 23-MAR-08:62 | 6.97 |
April | 21779594.76 | 1129.09 | 06-APR-08:62 | 5.37 |
May | 498675.57 | 311.38 | 05-MAY-08:03 | 19.87 |
June | 571727.89 | 484.42 | 06-JUN-08:04 | 24.27 |
July | 375906.99 | 328.60 | 12-JUL-08:05 | 23.07 |
August | 263309.43 | 321.00 | 09-AUG-08:05 | 26.38 |
September | 507321.69 | 417.20 | 14-SEP-08:03 | 15.55 |
October | 22935027.61 | 1132.11 | 30-OCT-15:01 | 11.60 |
November | 77357127.28 | 1149.11 | 30-NOV-16:02 | 7.20 |
December | 0.244126E+09 | 1156.13 | 25-DEC-16:02 | 6.02 |
Annual Sum or Average | 0.117004E+10 | |||
Minimum of Months | 263309.43 | 311.38 | -10.2 | |
Maximum of Months | 0.480149E+09 | 1188.27 | 26.38 |
Report: ZoneHeatingSummaryMonthly
For: BANQUET_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 5.70 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 9.92 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 15.32 |
April | 0.00 | 0.00 | 01-APR-00:10 | 12.05 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 9.70 |
December | 0.00 | 0.00 | 01-DEC-00:05 | 1.80 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 1.80 | |
Maximum of Months | 0.00 | 0.00 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: DINING_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 5.70 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 9.92 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 15.32 |
April | 0.00 | 0.00 | 01-APR-00:10 | 12.05 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 9.70 |
December | 0.00 | 0.00 | 01-DEC-00:05 | 1.80 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 1.80 | |
Maximum of Months | 0.00 | 0.00 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: KITCHEN_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 5.70 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 9.92 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 15.32 |
April | 0.00 | 0.00 | 01-APR-00:10 | 12.05 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 9.70 |
December | 0.00 | 0.00 | 01-DEC-00:05 | 1.80 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 1.80 | |
Maximum of Months | 0.00 | 0.00 | 25.13 |
Report: ZoneHeatingSummaryMonthly
For: CORRIDOR_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.235292E+10 | 3184.61 | 08-JAN-06:00 | -5.0 |
February | 0.127064E+10 | 3470.78 | 12-FEB-07:10 | -12.7 |
March | 77886229.55 | 1551.20 | 19-MAR-07:03 | 1.57 |
April | 35954846.60 | 1350.54 | 06-APR-06:10 | 1.20 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 |
October | 20094913.22 | 1179.39 | 26-OCT-06:40 | 2.20 |
November | 0.230090E+09 | 2643.98 | 22-NOV-07:10 | -3.2 |
December | 0.877044E+09 | 2956.89 | 18-DEC-07:40 | -5.4 |
Annual Sum or Average | 0.486463E+10 | |||
Minimum of Months | 0.00 | 0.00 | -12.7 | |
Maximum of Months | 0.235292E+10 | 3470.78 | 25.13 |
Report: ZoneElectricSummaryMonthly
For: BASEMENT
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.140333E+11 | 13517.00 | 02-JAN-20:10 | 0.127587E+11 | 10113.80 | 02-JAN-20:10 |
February | 0.126708E+11 | 13517.00 | 01-FEB-20:10 | 0.115208E+11 | 10113.80 | 01-FEB-20:10 |
March | 0.140766E+11 | 13517.00 | 01-MAR-20:10 | 0.127855E+11 | 10113.80 | 01-MAR-20:10 |
April | 0.135575E+11 | 13517.00 | 03-APR-19:10 | 0.123314E+11 | 10113.80 | 03-APR-19:10 |
May | 0.140576E+11 | 13517.00 | 01-MAY-19:10 | 0.127741E+11 | 10113.80 | 01-MAY-19:10 |
June | 0.136197E+11 | 13517.00 | 01-JUN-19:10 | 0.123716E+11 | 10113.80 | 01-JUN-19:10 |
July | 0.139955E+11 | 13517.00 | 03-JUL-19:10 | 0.127338E+11 | 10113.80 | 03-JUL-19:10 |
August | 0.140820E+11 | 13517.00 | 01-AUG-19:10 | 0.127894E+11 | 10113.80 | 01-AUG-19:10 |
September | 0.135629E+11 | 13517.00 | 01-SEP-19:10 | 0.123352E+11 | 10113.80 | 01-SEP-19:10 |
October | 0.140279E+11 | 13517.00 | 02-OCT-19:10 | 0.127549E+11 | 10113.80 | 02-OCT-19:10 |
November | 0.136089E+11 | 13517.00 | 01-NOV-19:10 | 0.123659E+11 | 10113.80 | 01-NOV-19:10 |
December | 0.139955E+11 | 13517.00 | 01-DEC-20:10 | 0.127338E+11 | 10113.80 | 01-DEC-20:10 |
Annual Sum or Average | 0.165288E+12 | 0.150255E+12 | ||||
Minimum of Months | 0.126708E+11 | 13517.00 | 0.115208E+11 | 10113.80 | ||
Maximum of Months | 0.140820E+11 | 13517.00 | 0.127894E+11 | 10113.80 |
Report: ZoneElectricSummaryMonthly
For: RETAIL_1_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.713551E+09 | 687.30 | 02-JAN-20:10 | 0.864900E+09 | 685.60 | 02-JAN-20:10 |
February | 0.644271E+09 | 687.30 | 01-FEB-20:10 | 0.780982E+09 | 685.60 | 01-FEB-20:10 |
March | 0.715750E+09 | 687.30 | 01-MAR-20:10 | 0.866718E+09 | 685.60 | 01-MAR-20:10 |
April | 0.689358E+09 | 687.30 | 03-APR-19:10 | 0.835931E+09 | 685.60 | 03-APR-19:10 |
May | 0.714788E+09 | 687.30 | 01-MAY-19:10 | 0.865939E+09 | 685.60 | 01-MAY-19:10 |
June | 0.692519E+09 | 687.30 | 01-JUN-19:10 | 0.838659E+09 | 685.60 | 01-JUN-19:10 |
July | 0.711626E+09 | 687.30 | 03-JUL-19:10 | 0.863211E+09 | 685.60 | 03-JUL-19:10 |
August | 0.716025E+09 | 687.30 | 01-AUG-19:10 | 0.866978E+09 | 685.60 | 01-AUG-19:10 |
September | 0.689633E+09 | 687.30 | 01-SEP-19:10 | 0.836191E+09 | 685.60 | 01-SEP-19:10 |
October | 0.713276E+09 | 687.30 | 02-OCT-19:10 | 0.864640E+09 | 685.60 | 02-OCT-19:10 |
November | 0.691970E+09 | 687.30 | 01-NOV-19:10 | 0.838269E+09 | 685.60 | 01-NOV-19:10 |
December | 0.711626E+09 | 687.30 | 01-DEC-20:10 | 0.863211E+09 | 685.60 | 01-DEC-20:10 |
Annual Sum or Average | 0.840439E+10 | 0.101856E+11 | ||||
Minimum of Months | 0.644271E+09 | 687.30 | 0.780982E+09 | 685.60 | ||
Maximum of Months | 0.716025E+09 | 687.30 | 0.866978E+09 | 685.60 |
Report: ZoneElectricSummaryMonthly
For: RETAIL_2_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.826294E+09 | 795.89 | 02-JAN-20:10 | 0.100156E+10 | 793.93 | 02-JAN-20:10 |
February | 0.746069E+09 | 795.89 | 01-FEB-20:10 | 0.904380E+09 | 793.93 | 01-FEB-20:10 |
March | 0.828841E+09 | 795.89 | 01-MAR-20:10 | 0.100366E+10 | 793.93 | 01-MAR-20:10 |
April | 0.798279E+09 | 795.89 | 03-APR-19:10 | 0.968011E+09 | 793.93 | 03-APR-19:10 |
May | 0.827727E+09 | 795.89 | 01-MAY-19:10 | 0.100276E+10 | 793.93 | 01-MAY-19:10 |
June | 0.801940E+09 | 795.89 | 01-JUN-19:10 | 0.971170E+09 | 793.93 | 01-JUN-19:10 |
July | 0.824066E+09 | 795.89 | 03-JUL-19:10 | 0.999601E+09 | 793.93 | 03-JUL-19:10 |
August | 0.829160E+09 | 795.89 | 01-AUG-19:10 | 0.100396E+10 | 793.93 | 01-AUG-19:10 |
September | 0.798597E+09 | 795.89 | 01-SEP-19:10 | 0.968312E+09 | 793.93 | 01-SEP-19:10 |
October | 0.825976E+09 | 795.89 | 02-OCT-19:10 | 0.100126E+10 | 793.93 | 02-OCT-19:10 |
November | 0.801303E+09 | 795.89 | 01-NOV-19:10 | 0.970719E+09 | 793.93 | 01-NOV-19:10 |
December | 0.824066E+09 | 795.89 | 01-DEC-20:10 | 0.999601E+09 | 793.93 | 01-DEC-20:10 |
Annual Sum or Average | 0.973232E+10 | 0.117950E+11 | ||||
Minimum of Months | 0.746069E+09 | 795.89 | 0.904380E+09 | 793.93 | ||
Maximum of Months | 0.829160E+09 | 795.89 | 0.100396E+10 | 793.93 |
Report: ZoneElectricSummaryMonthly
For: MECH_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.154452E+10 | 1487.69 | 02-JAN-20:10 | 0.105898E+10 | 839.45 | 02-JAN-20:10 |
February | 0.139456E+10 | 1487.69 | 01-FEB-20:10 | 0.956227E+09 | 839.45 | 01-FEB-20:10 |
March | 0.154928E+10 | 1487.69 | 01-MAR-20:10 | 0.106120E+10 | 839.45 | 01-MAR-20:10 |
April | 0.149215E+10 | 1487.69 | 03-APR-19:10 | 0.102351E+10 | 839.45 | 03-APR-19:10 |
May | 0.154719E+10 | 1487.69 | 01-MAY-19:10 | 0.106025E+10 | 839.45 | 01-MAY-19:10 |
June | 0.149899E+10 | 1487.69 | 01-JUN-19:10 | 0.102685E+10 | 839.45 | 01-JUN-19:10 |
July | 0.154035E+10 | 1487.69 | 03-JUL-19:10 | 0.105691E+10 | 839.45 | 03-JUL-19:10 |
August | 0.154987E+10 | 1487.69 | 01-AUG-19:10 | 0.106152E+10 | 839.45 | 01-AUG-19:10 |
September | 0.149274E+10 | 1487.69 | 01-SEP-19:10 | 0.102382E+10 | 839.45 | 01-SEP-19:10 |
October | 0.154392E+10 | 1487.69 | 02-OCT-19:10 | 0.105866E+10 | 839.45 | 02-OCT-19:10 |
November | 0.149780E+10 | 1487.69 | 01-NOV-19:10 | 0.102637E+10 | 839.45 | 01-NOV-19:10 |
December | 0.154035E+10 | 1487.69 | 01-DEC-20:10 | 0.105691E+10 | 839.45 | 01-DEC-20:10 |
Annual Sum or Average | 0.181917E+11 | 0.124712E+11 | ||||
Minimum of Months | 0.139456E+10 | 1487.69 | 0.956227E+09 | 839.45 | ||
Maximum of Months | 0.154987E+10 | 1487.69 | 0.106152E+10 | 839.45 |
Report: ZoneElectricSummaryMonthly
For: STORAGE_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.283535E+09 | 273.10 | 02-JAN-20:10 | 0.305485E+09 | 242.16 | 02-JAN-20:10 |
February | 0.256006E+09 | 273.10 | 01-FEB-20:10 | 0.275845E+09 | 242.16 | 01-FEB-20:10 |
March | 0.284409E+09 | 273.10 | 01-MAR-20:10 | 0.306128E+09 | 242.16 | 01-MAR-20:10 |
April | 0.273921E+09 | 273.10 | 03-APR-19:10 | 0.295253E+09 | 242.16 | 03-APR-19:10 |
May | 0.284026E+09 | 273.10 | 01-MAY-19:10 | 0.305852E+09 | 242.16 | 01-MAY-19:10 |
June | 0.275178E+09 | 273.10 | 01-JUN-19:10 | 0.296217E+09 | 242.16 | 01-JUN-19:10 |
July | 0.282770E+09 | 273.10 | 03-JUL-19:10 | 0.304889E+09 | 242.16 | 03-JUL-19:10 |
August | 0.284518E+09 | 273.10 | 01-AUG-19:10 | 0.306219E+09 | 242.16 | 01-AUG-19:10 |
September | 0.274031E+09 | 273.10 | 01-SEP-19:10 | 0.295345E+09 | 242.16 | 01-SEP-19:10 |
October | 0.283425E+09 | 273.10 | 02-OCT-19:10 | 0.305393E+09 | 242.16 | 02-OCT-19:10 |
November | 0.274959E+09 | 273.10 | 01-NOV-19:10 | 0.296079E+09 | 242.16 | 01-NOV-19:10 |
December | 0.282770E+09 | 273.10 | 01-DEC-20:10 | 0.304889E+09 | 242.16 | 01-DEC-20:10 |
Annual Sum or Average | 0.333955E+10 | 0.359760E+10 | ||||
Minimum of Months | 0.256006E+09 | 273.10 | 0.275845E+09 | 242.16 | ||
Maximum of Months | 0.284518E+09 | 273.10 | 0.306219E+09 | 242.16 |
Report: ZoneElectricSummaryMonthly
For: LAUNDRY_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.350256E+09 | 337.37 | 02-JAN-20:10 | 0.576866E+10 | 4572.80 | 02-JAN-20:10 |
February | 0.316249E+09 | 337.37 | 01-FEB-20:10 | 0.520895E+10 | 4572.80 | 01-FEB-20:10 |
March | 0.351336E+09 | 337.37 | 01-MAR-20:10 | 0.578079E+10 | 4572.80 | 01-MAR-20:10 |
April | 0.338381E+09 | 337.37 | 03-APR-19:10 | 0.557545E+10 | 4572.80 | 03-APR-19:10 |
May | 0.350863E+09 | 337.37 | 01-MAY-19:10 | 0.577559E+10 | 4572.80 | 01-MAY-19:10 |
June | 0.339933E+09 | 337.37 | 01-JUN-19:10 | 0.559364E+10 | 4572.80 | 01-JUN-19:10 |
July | 0.349311E+09 | 337.37 | 03-JUL-19:10 | 0.575740E+10 | 4572.80 | 03-JUL-19:10 |
August | 0.351471E+09 | 337.37 | 01-AUG-19:10 | 0.578252E+10 | 4572.80 | 01-AUG-19:10 |
September | 0.338516E+09 | 337.37 | 01-SEP-19:10 | 0.557718E+10 | 4572.80 | 01-SEP-19:10 |
October | 0.350121E+09 | 337.37 | 02-OCT-19:10 | 0.576693E+10 | 4572.80 | 02-OCT-19:10 |
November | 0.339663E+09 | 337.37 | 01-NOV-19:10 | 0.559104E+10 | 4572.80 | 01-NOV-19:10 |
December | 0.349311E+09 | 337.37 | 01-DEC-20:10 | 0.575740E+10 | 4572.80 | 01-DEC-20:10 |
Annual Sum or Average | 0.412541E+10 | 0.679355E+11 | ||||
Minimum of Months | 0.316249E+09 | 337.37 | 0.520895E+10 | 4572.80 | ||
Maximum of Months | 0.351471E+09 | 337.37 | 0.578252E+10 | 4572.80 |
Report: ZoneElectricSummaryMonthly
For: CAFE_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.226040E+10 | 2177.23 | 02-JAN-20:10 | 0.121771E+10 | 965.27 | 02-JAN-20:10 |
February | 0.204093E+10 | 2177.23 | 01-FEB-20:10 | 0.109956E+10 | 965.27 | 01-FEB-20:10 |
March | 0.226736E+10 | 2177.23 | 01-MAR-20:10 | 0.122027E+10 | 965.27 | 01-MAR-20:10 |
April | 0.218376E+10 | 2177.23 | 03-APR-19:10 | 0.117692E+10 | 965.27 | 03-APR-19:10 |
May | 0.226431E+10 | 2177.23 | 01-MAY-19:10 | 0.121917E+10 | 965.27 | 01-MAY-19:10 |
June | 0.219377E+10 | 2177.23 | 01-JUN-19:10 | 0.118076E+10 | 965.27 | 01-JUN-19:10 |
July | 0.225430E+10 | 2177.23 | 03-JUL-19:10 | 0.121533E+10 | 965.27 | 03-JUL-19:10 |
August | 0.226823E+10 | 2177.23 | 01-AUG-19:10 | 0.122063E+10 | 965.27 | 01-AUG-19:10 |
September | 0.218463E+10 | 2177.23 | 01-SEP-19:10 | 0.117729E+10 | 965.27 | 01-SEP-19:10 |
October | 0.225952E+10 | 2177.23 | 02-OCT-19:10 | 0.121734E+10 | 965.27 | 02-OCT-19:10 |
November | 0.219203E+10 | 2177.23 | 01-NOV-19:10 | 0.118021E+10 | 965.27 | 01-NOV-19:10 |
December | 0.225430E+10 | 2177.23 | 01-DEC-20:10 | 0.121533E+10 | 965.27 | 01-DEC-20:10 |
Annual Sum or Average | 0.266236E+11 | 0.143405E+11 | ||||
Minimum of Months | 0.204093E+10 | 2177.23 | 0.109956E+10 | 965.27 | ||
Maximum of Months | 0.226823E+10 | 2177.23 | 0.122063E+10 | 965.27 |
Report: ZoneElectricSummaryMonthly
For: LOBBY_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.123020E+11 | 11849.32 | 02-JAN-20:10 | 0.126520E+11 | 10029.21 | 02-JAN-20:10 |
February | 0.111075E+11 | 11849.32 | 01-FEB-20:10 | 0.114244E+11 | 10029.21 | 01-FEB-20:10 |
March | 0.123399E+11 | 11849.32 | 01-MAR-20:10 | 0.126786E+11 | 10029.21 | 01-MAR-20:10 |
April | 0.118849E+11 | 11849.32 | 03-APR-19:10 | 0.122282E+11 | 10029.21 | 03-APR-19:10 |
May | 0.123233E+11 | 11849.32 | 01-MAY-19:10 | 0.126672E+11 | 10029.21 | 01-MAY-19:10 |
June | 0.119394E+11 | 11849.32 | 01-JUN-19:10 | 0.122682E+11 | 10029.21 | 01-JUN-19:10 |
July | 0.122688E+11 | 11849.32 | 03-JUL-19:10 | 0.126273E+11 | 10029.21 | 03-JUL-19:10 |
August | 0.123446E+11 | 11849.32 | 01-AUG-19:10 | 0.126824E+11 | 10029.21 | 01-AUG-19:10 |
September | 0.118896E+11 | 11849.32 | 01-SEP-19:10 | 0.122320E+11 | 10029.21 | 01-SEP-19:10 |
October | 0.122972E+11 | 11849.32 | 02-OCT-19:10 | 0.126482E+11 | 10029.21 | 02-OCT-19:10 |
November | 0.119299E+11 | 11849.32 | 01-NOV-19:10 | 0.122624E+11 | 10029.21 | 01-NOV-19:10 |
December | 0.122688E+11 | 11849.32 | 01-DEC-20:10 | 0.126273E+11 | 10029.21 | 01-DEC-20:10 |
Annual Sum or Average | 0.144896E+12 | 0.148998E+12 | ||||
Minimum of Months | 0.111075E+11 | 11849.32 | 0.114244E+11 | 10029.21 | ||
Maximum of Months | 0.123446E+11 | 11849.32 | 0.126824E+11 | 10029.21 |
Report: ZoneElectricSummaryMonthly
For: ROOM_1_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.434056E+09 | 392.73 | 01-JAN-19:10 | 0.261068E+09 | 237.06 | 01-JAN-08:09 |
February | 0.391995E+09 | 392.73 | 01-FEB-20:10 | 0.235798E+09 | 237.06 | 01-FEB-07:10 |
March | 0.430607E+09 | 392.73 | 01-MAR-20:10 | 0.260708E+09 | 237.06 | 01-MAR-07:10 |
April | 0.420554E+09 | 392.73 | 01-APR-18:10 | 0.252705E+09 | 237.06 | 01-APR-07:10 |
May | 0.432331E+09 | 392.73 | 01-MAY-19:10 | 0.260888E+09 | 237.06 | 01-MAY-06:10 |
June | 0.417218E+09 | 392.73 | 01-JUN-19:10 | 0.252344E+09 | 237.06 | 01-JUN-06:10 |
July | 0.435725E+09 | 392.73 | 01-JUL-18:10 | 0.261248E+09 | 237.06 | 01-JUL-07:10 |
August | 0.430607E+09 | 392.73 | 01-AUG-19:10 | 0.260708E+09 | 237.06 | 01-AUG-06:10 |
September | 0.420667E+09 | 392.73 | 01-SEP-19:10 | 0.252705E+09 | 237.06 | 01-SEP-06:10 |
October | 0.434000E+09 | 392.73 | 01-OCT-18:10 | 0.261068E+09 | 237.06 | 01-OCT-07:10 |
November | 0.418886E+09 | 392.73 | 01-NOV-19:10 | 0.252524E+09 | 237.06 | 01-NOV-06:10 |
December | 0.435781E+09 | 392.73 | 01-DEC-20:10 | 0.261248E+09 | 237.06 | 01-DEC-07:10 |
Annual Sum or Average | 0.510243E+10 | 0.307301E+10 | ||||
Minimum of Months | 0.391995E+09 | 392.73 | 0.235798E+09 | 237.06 | ||
Maximum of Months | 0.435781E+09 | 392.73 | 0.261248E+09 | 237.06 |
Report: ZoneElectricSummaryMonthly
For: ROOM_2_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.434005E+09 | 392.68 | 01-JAN-19:10 | 0.261038E+09 | 237.03 | 01-JAN-08:09 |
February | 0.391949E+09 | 392.68 | 01-FEB-20:10 | 0.235770E+09 | 237.03 | 01-FEB-07:10 |
March | 0.430556E+09 | 392.68 | 01-MAR-20:10 | 0.260677E+09 | 237.03 | 01-MAR-07:10 |
April | 0.420505E+09 | 392.68 | 01-APR-18:10 | 0.252675E+09 | 237.03 | 01-APR-07:10 |
May | 0.432281E+09 | 392.68 | 01-MAY-19:10 | 0.260857E+09 | 237.03 | 01-MAY-06:10 |
June | 0.417169E+09 | 392.68 | 01-JUN-19:10 | 0.252315E+09 | 237.03 | 01-JUN-06:10 |
July | 0.435674E+09 | 392.68 | 01-JUL-18:10 | 0.261218E+09 | 237.03 | 01-JUL-07:10 |
August | 0.430556E+09 | 392.68 | 01-AUG-19:10 | 0.260677E+09 | 237.03 | 01-AUG-06:10 |
September | 0.420618E+09 | 392.68 | 01-SEP-19:10 | 0.252675E+09 | 237.03 | 01-SEP-06:10 |
October | 0.433949E+09 | 392.68 | 01-OCT-18:10 | 0.261038E+09 | 237.03 | 01-OCT-07:10 |
November | 0.418837E+09 | 392.68 | 01-NOV-19:10 | 0.252495E+09 | 237.03 | 01-NOV-06:10 |
December | 0.435730E+09 | 392.68 | 01-DEC-20:10 | 0.261218E+09 | 237.03 | 01-DEC-07:10 |
Annual Sum or Average | 0.510183E+10 | 0.307265E+10 | ||||
Minimum of Months | 0.391949E+09 | 392.68 | 0.235770E+09 | 237.03 | ||
Maximum of Months | 0.435730E+09 | 392.68 | 0.261218E+09 | 237.03 |
Report: ZoneElectricSummaryMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.272788E+09 | 246.81 | 01-JAN-19:10 | 0.255708E+09 | 232.19 | 01-JAN-08:09 |
February | 0.246354E+09 | 246.81 | 01-FEB-20:10 | 0.230956E+09 | 232.19 | 01-FEB-07:10 |
March | 0.270620E+09 | 246.81 | 01-MAR-20:10 | 0.255355E+09 | 232.19 | 01-MAR-07:10 |
April | 0.264302E+09 | 246.81 | 01-APR-18:10 | 0.247516E+09 | 232.19 | 01-APR-07:10 |
May | 0.271704E+09 | 246.81 | 01-MAY-19:10 | 0.255532E+09 | 232.19 | 01-MAY-06:10 |
June | 0.262205E+09 | 246.81 | 01-JUN-19:10 | 0.247163E+09 | 232.19 | 01-JUN-06:10 |
July | 0.273836E+09 | 246.81 | 01-JUL-18:10 | 0.255885E+09 | 232.19 | 01-JUL-07:10 |
August | 0.270620E+09 | 246.81 | 01-AUG-19:10 | 0.255355E+09 | 232.19 | 01-AUG-06:10 |
September | 0.264373E+09 | 246.81 | 01-SEP-19:10 | 0.247516E+09 | 232.19 | 01-SEP-06:10 |
October | 0.272752E+09 | 246.81 | 01-OCT-18:10 | 0.255708E+09 | 232.19 | 01-OCT-07:10 |
November | 0.263254E+09 | 246.81 | 01-NOV-19:10 | 0.247340E+09 | 232.19 | 01-NOV-06:10 |
December | 0.273872E+09 | 246.81 | 01-DEC-20:10 | 0.255885E+09 | 232.19 | 01-DEC-07:10 |
Annual Sum or Average | 0.320668E+10 | 0.300992E+10 | ||||
Minimum of Months | 0.246354E+09 | 246.81 | 0.230956E+09 | 232.19 | ||
Maximum of Months | 0.273872E+09 | 246.81 | 0.255885E+09 | 232.19 |
Report: ZoneElectricSummaryMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.272862E+09 | 246.88 | 01-JAN-19:10 | 0.255778E+09 | 232.26 | 01-JAN-08:09 |
February | 0.246421E+09 | 246.88 | 01-FEB-20:10 | 0.231020E+09 | 232.26 | 01-FEB-07:10 |
March | 0.270694E+09 | 246.88 | 01-MAR-20:10 | 0.255425E+09 | 232.26 | 01-MAR-07:10 |
April | 0.264375E+09 | 246.88 | 01-APR-18:10 | 0.247584E+09 | 232.26 | 01-APR-07:10 |
May | 0.271778E+09 | 246.88 | 01-MAY-19:10 | 0.255602E+09 | 232.26 | 01-MAY-06:10 |
June | 0.262277E+09 | 246.88 | 01-JUN-19:10 | 0.247231E+09 | 232.26 | 01-JUN-06:10 |
July | 0.273911E+09 | 246.88 | 01-JUL-18:10 | 0.255955E+09 | 232.26 | 01-JUL-07:10 |
August | 0.270694E+09 | 246.88 | 01-AUG-19:10 | 0.255425E+09 | 232.26 | 01-AUG-06:10 |
September | 0.264446E+09 | 246.88 | 01-SEP-19:10 | 0.247584E+09 | 232.26 | 01-SEP-06:10 |
October | 0.272827E+09 | 246.88 | 01-OCT-18:10 | 0.255778E+09 | 232.26 | 01-OCT-07:10 |
November | 0.263326E+09 | 246.88 | 01-NOV-19:10 | 0.247408E+09 | 232.26 | 01-NOV-06:10 |
December | 0.273947E+09 | 246.88 | 01-DEC-20:10 | 0.255955E+09 | 232.26 | 01-DEC-07:10 |
Annual Sum or Average | 0.320756E+10 | 0.301074E+10 | ||||
Minimum of Months | 0.246421E+09 | 246.88 | 0.231020E+09 | 232.26 | ||
Maximum of Months | 0.273947E+09 | 246.88 | 0.255955E+09 | 232.26 |
Report: ZoneElectricSummaryMonthly
For: ROOM_5_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.434056E+09 | 392.73 | 01-JAN-19:10 | 0.261068E+09 | 237.06 | 01-JAN-08:09 |
February | 0.391995E+09 | 392.73 | 01-FEB-20:10 | 0.235798E+09 | 237.06 | 01-FEB-07:10 |
March | 0.430607E+09 | 392.73 | 01-MAR-20:10 | 0.260708E+09 | 237.06 | 01-MAR-07:10 |
April | 0.420554E+09 | 392.73 | 01-APR-18:10 | 0.252705E+09 | 237.06 | 01-APR-07:10 |
May | 0.432331E+09 | 392.73 | 01-MAY-19:10 | 0.260888E+09 | 237.06 | 01-MAY-06:10 |
June | 0.417218E+09 | 392.73 | 01-JUN-19:10 | 0.252344E+09 | 237.06 | 01-JUN-06:10 |
July | 0.435725E+09 | 392.73 | 01-JUL-18:10 | 0.261248E+09 | 237.06 | 01-JUL-07:10 |
August | 0.430607E+09 | 392.73 | 01-AUG-19:10 | 0.260708E+09 | 237.06 | 01-AUG-06:10 |
September | 0.420667E+09 | 392.73 | 01-SEP-19:10 | 0.252705E+09 | 237.06 | 01-SEP-06:10 |
October | 0.434000E+09 | 392.73 | 01-OCT-18:10 | 0.261068E+09 | 237.06 | 01-OCT-07:10 |
November | 0.418886E+09 | 392.73 | 01-NOV-19:10 | 0.252524E+09 | 237.06 | 01-NOV-06:10 |
December | 0.435781E+09 | 392.73 | 01-DEC-20:10 | 0.261248E+09 | 237.06 | 01-DEC-07:10 |
Annual Sum or Average | 0.510243E+10 | 0.307301E+10 | ||||
Minimum of Months | 0.391995E+09 | 392.73 | 0.235798E+09 | 237.06 | ||
Maximum of Months | 0.435781E+09 | 392.73 | 0.261248E+09 | 237.06 |
Report: ZoneElectricSummaryMonthly
For: ROOM_6_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.434005E+09 | 392.68 | 01-JAN-19:10 | 0.261038E+09 | 237.03 | 01-JAN-08:09 |
February | 0.391949E+09 | 392.68 | 01-FEB-20:10 | 0.235770E+09 | 237.03 | 01-FEB-07:10 |
March | 0.430556E+09 | 392.68 | 01-MAR-20:10 | 0.260677E+09 | 237.03 | 01-MAR-07:10 |
April | 0.420505E+09 | 392.68 | 01-APR-18:10 | 0.252675E+09 | 237.03 | 01-APR-07:10 |
May | 0.432281E+09 | 392.68 | 01-MAY-19:10 | 0.260857E+09 | 237.03 | 01-MAY-06:10 |
June | 0.417169E+09 | 392.68 | 01-JUN-19:10 | 0.252315E+09 | 237.03 | 01-JUN-06:10 |
July | 0.435674E+09 | 392.68 | 01-JUL-18:10 | 0.261218E+09 | 237.03 | 01-JUL-07:10 |
August | 0.430556E+09 | 392.68 | 01-AUG-19:10 | 0.260677E+09 | 237.03 | 01-AUG-06:10 |
September | 0.420618E+09 | 392.68 | 01-SEP-19:10 | 0.252675E+09 | 237.03 | 01-SEP-06:10 |
October | 0.433949E+09 | 392.68 | 01-OCT-18:10 | 0.261038E+09 | 237.03 | 01-OCT-07:10 |
November | 0.418837E+09 | 392.68 | 01-NOV-19:10 | 0.252495E+09 | 237.03 | 01-NOV-06:10 |
December | 0.435730E+09 | 392.68 | 01-DEC-20:10 | 0.261218E+09 | 237.03 | 01-DEC-07:10 |
Annual Sum or Average | 0.510183E+10 | 0.307265E+10 | ||||
Minimum of Months | 0.391949E+09 | 392.68 | 0.235770E+09 | 237.03 | ||
Maximum of Months | 0.435730E+09 | 392.68 | 0.261218E+09 | 237.03 |
Report: ZoneElectricSummaryMonthly
For: CORRIDOR_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
January | 0.133160E+10 | 1282.60 | 02-JAN-20:10 | 0.00 | 0.00 |
February | 0.120231E+10 | 1282.60 | 01-FEB-20:10 | 0.00 | 0.00 |
March | 0.133570E+10 | 1282.60 | 01-MAR-20:10 | 0.00 | 0.00 |
April | 0.128645E+10 | 1282.60 | 03-APR-19:10 | 0.00 | 0.00 |
May | 0.133391E+10 | 1282.60 | 01-MAY-19:10 | 0.00 | 0.00 |
June | 0.129235E+10 | 1282.60 | 01-JUN-19:10 | 0.00 | 0.00 |
July | 0.132801E+10 | 1282.60 | 03-JUL-19:10 | 0.00 | 0.00 |
August | 0.133622E+10 | 1282.60 | 01-AUG-19:10 | 0.00 | 0.00 |
September | 0.128696E+10 | 1282.60 | 01-SEP-19:10 | 0.00 | 0.00 |
October | 0.133109E+10 | 1282.60 | 02-OCT-19:10 | 0.00 | 0.00 |
November | 0.129132E+10 | 1282.60 | 01-NOV-19:10 | 0.00 | 0.00 |
December | 0.132801E+10 | 1282.60 | 01-DEC-20:10 | 0.00 | 0.00 |
Annual Sum or Average | 0.156839E+11 | 0.00 | 0.00 | ||
Minimum of Months | 0.120231E+10 | 1282.60 | 0.00 | 0.00 | |
Maximum of Months | 0.133622E+10 | 1282.60 | 0.00 | 0.00 |
Report: ZoneElectricSummaryMonthly
For: ROOM_1_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.434056E+09 | 392.73 | 01-JAN-19:10 | 0.261068E+09 | 237.06 | 01-JAN-08:09 |
February | 0.391995E+09 | 392.73 | 01-FEB-20:10 | 0.235798E+09 | 237.06 | 01-FEB-07:10 |
March | 0.430607E+09 | 392.73 | 01-MAR-20:10 | 0.260708E+09 | 237.06 | 01-MAR-07:10 |
April | 0.420554E+09 | 392.73 | 01-APR-18:10 | 0.252705E+09 | 237.06 | 01-APR-07:10 |
May | 0.432331E+09 | 392.73 | 01-MAY-19:10 | 0.260888E+09 | 237.06 | 01-MAY-06:10 |
June | 0.417218E+09 | 392.73 | 01-JUN-19:10 | 0.252344E+09 | 237.06 | 01-JUN-06:10 |
July | 0.435725E+09 | 392.73 | 01-JUL-18:10 | 0.261248E+09 | 237.06 | 01-JUL-07:10 |
August | 0.430607E+09 | 392.73 | 01-AUG-19:10 | 0.260708E+09 | 237.06 | 01-AUG-06:10 |
September | 0.420667E+09 | 392.73 | 01-SEP-19:10 | 0.252705E+09 | 237.06 | 01-SEP-06:10 |
October | 0.434000E+09 | 392.73 | 01-OCT-18:10 | 0.261068E+09 | 237.06 | 01-OCT-07:10 |
November | 0.418886E+09 | 392.73 | 01-NOV-19:10 | 0.252524E+09 | 237.06 | 01-NOV-06:10 |
December | 0.435781E+09 | 392.73 | 01-DEC-20:10 | 0.261248E+09 | 237.06 | 01-DEC-07:10 |
Annual Sum or Average | 0.510243E+10 | 0.307301E+10 | ||||
Minimum of Months | 0.391995E+09 | 392.73 | 0.235798E+09 | 237.06 | ||
Maximum of Months | 0.435781E+09 | 392.73 | 0.261248E+09 | 237.06 |
Report: ZoneElectricSummaryMonthly
For: ROOM_2_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.434005E+09 | 392.68 | 01-JAN-19:10 | 0.261038E+09 | 237.03 | 01-JAN-08:09 |
February | 0.391949E+09 | 392.68 | 01-FEB-20:10 | 0.235770E+09 | 237.03 | 01-FEB-07:10 |
March | 0.430556E+09 | 392.68 | 01-MAR-20:10 | 0.260677E+09 | 237.03 | 01-MAR-07:10 |
April | 0.420505E+09 | 392.68 | 01-APR-18:10 | 0.252675E+09 | 237.03 | 01-APR-07:10 |
May | 0.432281E+09 | 392.68 | 01-MAY-19:10 | 0.260857E+09 | 237.03 | 01-MAY-06:10 |
June | 0.417169E+09 | 392.68 | 01-JUN-19:10 | 0.252315E+09 | 237.03 | 01-JUN-06:10 |
July | 0.435674E+09 | 392.68 | 01-JUL-18:10 | 0.261218E+09 | 237.03 | 01-JUL-07:10 |
August | 0.430556E+09 | 392.68 | 01-AUG-19:10 | 0.260677E+09 | 237.03 | 01-AUG-06:10 |
September | 0.420618E+09 | 392.68 | 01-SEP-19:10 | 0.252675E+09 | 237.03 | 01-SEP-06:10 |
October | 0.433949E+09 | 392.68 | 01-OCT-18:10 | 0.261038E+09 | 237.03 | 01-OCT-07:10 |
November | 0.418837E+09 | 392.68 | 01-NOV-19:10 | 0.252495E+09 | 237.03 | 01-NOV-06:10 |
December | 0.435730E+09 | 392.68 | 01-DEC-20:10 | 0.261218E+09 | 237.03 | 01-DEC-07:10 |
Annual Sum or Average | 0.510183E+10 | 0.307265E+10 | ||||
Minimum of Months | 0.391949E+09 | 392.68 | 0.235770E+09 | 237.03 | ||
Maximum of Months | 0.435730E+09 | 392.68 | 0.261218E+09 | 237.03 |
Report: ZoneElectricSummaryMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.272862E+09 | 246.88 | 01-JAN-19:10 | 0.255778E+09 | 232.26 | 01-JAN-08:09 |
February | 0.246421E+09 | 246.88 | 01-FEB-20:10 | 0.231020E+09 | 232.26 | 01-FEB-07:10 |
March | 0.270694E+09 | 246.88 | 01-MAR-20:10 | 0.255425E+09 | 232.26 | 01-MAR-07:10 |
April | 0.264375E+09 | 246.88 | 01-APR-18:10 | 0.247584E+09 | 232.26 | 01-APR-07:10 |
May | 0.271778E+09 | 246.88 | 01-MAY-19:10 | 0.255602E+09 | 232.26 | 01-MAY-06:10 |
June | 0.262277E+09 | 246.88 | 01-JUN-19:10 | 0.247231E+09 | 232.26 | 01-JUN-06:10 |
July | 0.273911E+09 | 246.88 | 01-JUL-18:10 | 0.255955E+09 | 232.26 | 01-JUL-07:10 |
August | 0.270694E+09 | 246.88 | 01-AUG-19:10 | 0.255425E+09 | 232.26 | 01-AUG-06:10 |
September | 0.264446E+09 | 246.88 | 01-SEP-19:10 | 0.247584E+09 | 232.26 | 01-SEP-06:10 |
October | 0.272827E+09 | 246.88 | 01-OCT-18:10 | 0.255778E+09 | 232.26 | 01-OCT-07:10 |
November | 0.263326E+09 | 246.88 | 01-NOV-19:10 | 0.247408E+09 | 232.26 | 01-NOV-06:10 |
December | 0.273947E+09 | 246.88 | 01-DEC-20:10 | 0.255955E+09 | 232.26 | 01-DEC-07:10 |
Annual Sum or Average | 0.320756E+10 | 0.301074E+10 | ||||
Minimum of Months | 0.246421E+09 | 246.88 | 0.231020E+09 | 232.26 | ||
Maximum of Months | 0.273947E+09 | 246.88 | 0.255955E+09 | 232.26 |
Report: ZoneElectricSummaryMonthly
For: BANQUET_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.396945E+10 | 3823.39 | 02-JAN-20:10 | 0.149358E+11 | 6747.90 | 01-JAN-07:10 |
February | 0.358405E+10 | 3823.39 | 01-FEB-20:10 | 0.134904E+11 | 6747.90 | 01-FEB-07:10 |
March | 0.398168E+10 | 3823.39 | 01-MAR-20:10 | 0.149358E+11 | 6747.90 | 01-MAR-07:10 |
April | 0.383486E+10 | 3823.39 | 03-APR-19:10 | 0.144540E+11 | 6747.90 | 01-APR-06:10 |
May | 0.397633E+10 | 3823.39 | 01-MAY-19:10 | 0.149358E+11 | 6747.90 | 01-MAY-06:10 |
June | 0.385245E+10 | 3823.39 | 01-JUN-19:10 | 0.144540E+11 | 6747.90 | 01-JUN-06:10 |
July | 0.395874E+10 | 3823.39 | 03-JUL-19:10 | 0.149358E+11 | 6747.90 | 01-JUL-06:10 |
August | 0.398321E+10 | 3823.39 | 01-AUG-19:10 | 0.149358E+11 | 6747.90 | 01-AUG-06:10 |
September | 0.383639E+10 | 3823.39 | 01-SEP-19:10 | 0.144540E+11 | 6747.90 | 01-SEP-06:10 |
October | 0.396792E+10 | 3823.39 | 02-OCT-19:10 | 0.149358E+11 | 6747.90 | 01-OCT-06:10 |
November | 0.384939E+10 | 3823.39 | 01-NOV-19:10 | 0.144540E+11 | 6747.90 | 01-NOV-06:10 |
December | 0.395874E+10 | 3823.39 | 01-DEC-20:10 | 0.149358E+11 | 6747.90 | 01-DEC-07:10 |
Annual Sum or Average | 0.467532E+11 | 0.175857E+12 | ||||
Minimum of Months | 0.358405E+10 | 3823.39 | 0.134904E+11 | 6747.90 | ||
Maximum of Months | 0.398321E+10 | 3823.39 | 0.149358E+11 | 6747.90 |
Report: ZoneElectricSummaryMonthly
For: DINING_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.396945E+10 | 3823.39 | 02-JAN-20:10 | 0.149358E+11 | 6747.90 | 01-JAN-07:10 |
February | 0.358405E+10 | 3823.39 | 01-FEB-20:10 | 0.134904E+11 | 6747.90 | 01-FEB-07:10 |
March | 0.398168E+10 | 3823.39 | 01-MAR-20:10 | 0.149358E+11 | 6747.90 | 01-MAR-07:10 |
April | 0.383486E+10 | 3823.39 | 03-APR-19:10 | 0.144540E+11 | 6747.90 | 01-APR-06:10 |
May | 0.397633E+10 | 3823.39 | 01-MAY-19:10 | 0.149358E+11 | 6747.90 | 01-MAY-06:10 |
June | 0.385245E+10 | 3823.39 | 01-JUN-19:10 | 0.144540E+11 | 6747.90 | 01-JUN-06:10 |
July | 0.395874E+10 | 3823.39 | 03-JUL-19:10 | 0.149358E+11 | 6747.90 | 01-JUL-06:10 |
August | 0.398321E+10 | 3823.39 | 01-AUG-19:10 | 0.149358E+11 | 6747.90 | 01-AUG-06:10 |
September | 0.383639E+10 | 3823.39 | 01-SEP-19:10 | 0.144540E+11 | 6747.90 | 01-SEP-06:10 |
October | 0.396792E+10 | 3823.39 | 02-OCT-19:10 | 0.149358E+11 | 6747.90 | 01-OCT-06:10 |
November | 0.384939E+10 | 3823.39 | 01-NOV-19:10 | 0.144540E+11 | 6747.90 | 01-NOV-06:10 |
December | 0.395874E+10 | 3823.39 | 01-DEC-20:10 | 0.149358E+11 | 6747.90 | 01-DEC-07:10 |
Annual Sum or Average | 0.467532E+11 | 0.175857E+12 | ||||
Minimum of Months | 0.358405E+10 | 3823.39 | 0.134904E+11 | 6747.90 | ||
Maximum of Months | 0.398321E+10 | 3823.39 | 0.149358E+11 | 6747.90 |
Report: ZoneElectricSummaryMonthly
For: KITCHEN_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.105977E+10 | 1020.78 | 02-JAN-20:10 | 0.373720E+11 | 16686.59 | 01-JAN-07:10 |
February | 0.956878E+09 | 1020.78 | 01-FEB-20:10 | 0.337554E+11 | 16686.59 | 01-FEB-07:10 |
March | 0.106304E+10 | 1020.78 | 01-MAR-20:10 | 0.373720E+11 | 16686.59 | 01-MAR-07:10 |
April | 0.102384E+10 | 1020.78 | 03-APR-19:10 | 0.361665E+11 | 16686.59 | 01-APR-06:10 |
May | 0.106161E+10 | 1020.78 | 01-MAY-19:10 | 0.373720E+11 | 16686.59 | 01-MAY-06:10 |
June | 0.102854E+10 | 1020.78 | 01-JUN-19:10 | 0.361665E+11 | 16686.59 | 01-JUN-06:10 |
July | 0.105691E+10 | 1020.78 | 03-JUL-19:10 | 0.373720E+11 | 16686.59 | 01-JUL-06:10 |
August | 0.106345E+10 | 1020.78 | 01-AUG-19:10 | 0.373720E+11 | 16686.59 | 01-AUG-06:10 |
September | 0.102425E+10 | 1020.78 | 01-SEP-19:10 | 0.361665E+11 | 16686.59 | 01-SEP-06:10 |
October | 0.105936E+10 | 1020.78 | 02-OCT-19:10 | 0.373720E+11 | 16686.59 | 01-OCT-06:10 |
November | 0.102772E+10 | 1020.78 | 01-NOV-19:10 | 0.361665E+11 | 16686.59 | 01-NOV-06:10 |
December | 0.105691E+10 | 1020.78 | 01-DEC-20:10 | 0.373720E+11 | 16686.59 | 01-DEC-07:10 |
Annual Sum or Average | 0.124823E+11 | 0.440025E+12 | ||||
Minimum of Months | 0.956878E+09 | 1020.78 | 0.337554E+11 | 16686.59 | ||
Maximum of Months | 0.106345E+10 | 1020.78 | 0.373720E+11 | 16686.59 |
Report: ZoneElectricSummaryMonthly
For: CORRIDOR_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [] | |
January | 0.140929E+10 | 1357.44 | 02-JAN-20:10 | 0.00 | 0.00 |
February | 0.127246E+10 | 1357.44 | 01-FEB-20:10 | 0.00 | 0.00 |
March | 0.141364E+10 | 1357.44 | 01-MAR-20:10 | 0.00 | 0.00 |
April | 0.136151E+10 | 1357.44 | 03-APR-19:10 | 0.00 | 0.00 |
May | 0.141173E+10 | 1357.44 | 01-MAY-19:10 | 0.00 | 0.00 |
June | 0.136775E+10 | 1357.44 | 01-JUN-19:10 | 0.00 | 0.00 |
July | 0.140549E+10 | 1357.44 | 03-JUL-19:10 | 0.00 | 0.00 |
August | 0.141418E+10 | 1357.44 | 01-AUG-19:10 | 0.00 | 0.00 |
September | 0.136205E+10 | 1357.44 | 01-SEP-19:10 | 0.00 | 0.00 |
October | 0.140875E+10 | 1357.44 | 02-OCT-19:10 | 0.00 | 0.00 |
November | 0.136667E+10 | 1357.44 | 01-NOV-19:10 | 0.00 | 0.00 |
December | 0.140549E+10 | 1357.44 | 01-DEC-20:10 | 0.00 | 0.00 |
Annual Sum or Average | 0.165990E+11 | 0.00 | 0.00 | ||
Minimum of Months | 0.127246E+10 | 1357.44 | 0.00 | 0.00 | |
Maximum of Months | 0.141418E+10 | 1357.44 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: BASEMENT
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.195762E+11 | 0.140333E+11 | 0.127587E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.176991E+11 | 0.126708E+11 | 0.115208E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.196682E+11 | 0.140766E+11 | 0.127855E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.189781E+11 | 0.135575E+11 | 0.123314E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.196176E+11 | 0.140576E+11 | 0.127741E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.190195E+11 | 0.136197E+11 | 0.123716E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.195762E+11 | 0.139955E+11 | 0.127338E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.196590E+11 | 0.140820E+11 | 0.127894E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.189689E+11 | 0.135629E+11 | 0.123352E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.195854E+11 | 0.140279E+11 | 0.127549E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.189367E+11 | 0.136089E+11 | 0.123659E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.195762E+11 | 0.139955E+11 | 0.127338E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.230861E+12 | 0.165288E+12 | 0.150255E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.176991E+11 | 0.126708E+11 | 0.115208E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.196682E+11 | 0.140820E+11 | 0.127894E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: RETAIL_1_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.199054E+10 | 0.713551E+09 | 0.864900E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1317.40 | 0.101253E+10 |
February | 0.179968E+10 | 0.644271E+09 | 0.780982E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2571337.47 | 0.700809E+09 |
March | 0.199990E+10 | 0.715750E+09 | 0.866718E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12484786.76 | 0.431962E+09 |
April | 0.192973E+10 | 0.689358E+09 | 0.835931E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 45077720.56 | 0.259708E+09 |
May | 0.199475E+10 | 0.714788E+09 | 0.865939E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 98008828.09 | 0.112897E+09 |
June | 0.193394E+10 | 0.692519E+09 | 0.838659E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.221210E+09 | 28837100.80 |
July | 0.199054E+10 | 0.711626E+09 | 0.863211E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.273700E+09 | 9361911.11 |
August | 0.199896E+10 | 0.716025E+09 | 0.866978E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.286882E+09 | 827399.17 |
September | 0.192879E+10 | 0.689633E+09 | 0.836191E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.125445E+09 | 55426704.58 |
October | 0.199148E+10 | 0.713276E+09 | 0.864640E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 25912331.16 | 0.319060E+09 |
November | 0.192552E+10 | 0.691970E+09 | 0.838269E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2901516.96 | 0.514112E+09 |
December | 0.199054E+10 | 0.711626E+09 | 0.863211E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 274459.27 | 0.781246E+09 |
Annual Sum or Average | 0.234744E+11 | 0.840439E+10 | 0.101856E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109447E+10 | 0.422678E+10 |
Minimum of Months | 0.179968E+10 | 0.644271E+09 | 0.780982E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1317.40 | 827399.17 |
Maximum of Months | 0.199990E+10 | 0.716025E+09 | 0.866978E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.286882E+09 | 0.101253E+10 |
Report: SpaceGainsMonthly
For: RETAIL_2_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.230505E+10 | 0.826294E+09 | 0.100156E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 497.53 | 0.391172E+09 |
February | 0.208403E+10 | 0.746069E+09 | 0.904380E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1320572.24 | 0.270865E+09 |
March | 0.231589E+10 | 0.828841E+09 | 0.100366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5137391.37 | 0.167189E+09 |
April | 0.223463E+10 | 0.798279E+09 | 0.968011E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 18131651.56 | 0.101696E+09 |
May | 0.230993E+10 | 0.827727E+09 | 0.100276E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37426916.57 | 45208457.32 |
June | 0.223950E+10 | 0.801940E+09 | 0.971170E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 83619518.11 | 12184458.24 |
July | 0.230505E+10 | 0.824066E+09 | 0.999601E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103888E+09 | 4043417.82 |
August | 0.231480E+10 | 0.829160E+09 | 0.100396E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109840E+09 | 429120.14 |
September | 0.223354E+10 | 0.798597E+09 | 0.968312E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 49173277.10 | 22275036.79 |
October | 0.230614E+10 | 0.825976E+09 | 0.100126E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11560261.32 | 0.123449E+09 |
November | 0.222975E+10 | 0.801303E+09 | 0.970719E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1267807.03 | 0.197516E+09 |
December | 0.230505E+10 | 0.824066E+09 | 0.999601E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 159415.40 | 0.301127E+09 |
Annual Sum or Average | 0.271834E+11 | 0.973232E+10 | 0.117950E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.421525E+09 | 0.163716E+10 |
Minimum of Months | 0.208403E+10 | 0.746069E+09 | 0.904380E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 497.53 | 429120.14 |
Maximum of Months | 0.231589E+10 | 0.829160E+09 | 0.100396E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109840E+09 | 0.391172E+09 |
Report: SpaceGainsMonthly
For: MECH_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.487480E+09 | 0.154452E+10 | 0.105898E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1224.94 | 0.924190E+09 |
February | 0.440737E+09 | 0.139456E+10 | 0.956227E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3124709.70 | 0.639225E+09 |
March | 0.489771E+09 | 0.154928E+10 | 0.106120E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12504176.16 | 0.392897E+09 |
April | 0.472586E+09 | 0.149215E+10 | 0.102351E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43269865.45 | 0.237352E+09 |
May | 0.488511E+09 | 0.154719E+10 | 0.106025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 89671160.76 | 0.103843E+09 |
June | 0.473617E+09 | 0.149899E+10 | 0.102685E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.200780E+09 | 26923433.08 |
July | 0.487480E+09 | 0.154035E+10 | 0.105691E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.249744E+09 | 8896085.12 |
August | 0.489542E+09 | 0.154987E+10 | 0.106152E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.265740E+09 | 790971.83 |
September | 0.472357E+09 | 0.149274E+10 | 0.102382E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.119459E+09 | 50949041.83 |
October | 0.487709E+09 | 0.154392E+10 | 0.105866E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27712995.80 | 0.289151E+09 |
November | 0.471555E+09 | 0.149780E+10 | 0.102637E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3038276.11 | 0.465446E+09 |
December | 0.487480E+09 | 0.154035E+10 | 0.105691E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 376739.22 | 0.711195E+09 |
Annual Sum or Average | 0.574883E+10 | 0.181917E+11 | 0.124712E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101542E+10 | 0.385086E+10 |
Minimum of Months | 0.440737E+09 | 0.139456E+10 | 0.956227E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1224.94 | 790971.83 |
Maximum of Months | 0.489771E+09 | 0.154987E+10 | 0.106152E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.265740E+09 | 0.924190E+09 |
Report: SpaceGainsMonthly
For: STORAGE_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.374985E+09 | 0.283535E+09 | 0.305485E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 721.24 | 0.532902E+09 |
February | 0.339028E+09 | 0.256006E+09 | 0.275845E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1802780.02 | 0.368502E+09 |
March | 0.376747E+09 | 0.284409E+09 | 0.306128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 7306668.82 | 0.226654E+09 |
April | 0.363528E+09 | 0.273921E+09 | 0.295253E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 25037093.39 | 0.136643E+09 |
May | 0.375778E+09 | 0.284026E+09 | 0.305852E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 52277498.30 | 59431203.23 |
June | 0.364321E+09 | 0.275178E+09 | 0.296217E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117416E+09 | 15263607.25 |
July | 0.374985E+09 | 0.282770E+09 | 0.304889E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.145931E+09 | 4948123.80 |
August | 0.376571E+09 | 0.284518E+09 | 0.306219E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.155450E+09 | 435168.45 |
September | 0.363352E+09 | 0.274031E+09 | 0.295345E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 69747268.95 | 29164336.30 |
October | 0.375161E+09 | 0.283425E+09 | 0.305393E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16108134.29 | 0.166699E+09 |
November | 0.362735E+09 | 0.274959E+09 | 0.296079E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1752868.27 | 0.268519E+09 |
December | 0.374985E+09 | 0.282770E+09 | 0.304889E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 217378.99 | 0.410319E+09 |
Annual Sum or Average | 0.442217E+10 | 0.333955E+10 | 0.359760E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.593047E+09 | 0.221948E+10 |
Minimum of Months | 0.339028E+09 | 0.256006E+09 | 0.275845E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 721.24 | 435168.45 |
Maximum of Months | 0.376747E+09 | 0.284518E+09 | 0.306219E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.155450E+09 | 0.532902E+09 |
Report: SpaceGainsMonthly
For: LAUNDRY_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.154405E+10 | 0.350256E+09 | 0.576866E+10 | 0.501157E+11 | 0.00 | 0.00 | 0.00 | 1113.09 | 0.129250E+10 |
February | 0.139600E+10 | 0.316249E+09 | 0.520895E+10 | 0.452532E+11 | 0.00 | 0.00 | 0.00 | 4220063.53 | 0.900017E+09 |
March | 0.155131E+10 | 0.351336E+09 | 0.578079E+10 | 0.502211E+11 | 0.00 | 0.00 | 0.00 | 14304101.67 | 0.563005E+09 |
April | 0.149688E+10 | 0.338381E+09 | 0.557545E+10 | 0.484372E+11 | 0.00 | 0.00 | 0.00 | 55219319.90 | 0.345912E+09 |
May | 0.154732E+10 | 0.350863E+09 | 0.577559E+10 | 0.501759E+11 | 0.00 | 0.00 | 0.00 | 0.113946E+09 | 0.156975E+09 |
June | 0.150015E+10 | 0.339933E+09 | 0.559364E+10 | 0.485952E+11 | 0.00 | 0.00 | 0.00 | 0.260506E+09 | 40689165.37 |
July | 0.154405E+10 | 0.349311E+09 | 0.575740E+10 | 0.500179E+11 | 0.00 | 0.00 | 0.00 | 0.330396E+09 | 15450435.01 |
August | 0.155059E+10 | 0.351471E+09 | 0.578252E+10 | 0.502361E+11 | 0.00 | 0.00 | 0.00 | 0.348708E+09 | 1987511.29 |
September | 0.149615E+10 | 0.338516E+09 | 0.557718E+10 | 0.484522E+11 | 0.00 | 0.00 | 0.00 | 0.150950E+09 | 79483604.71 |
October | 0.154478E+10 | 0.350121E+09 | 0.576693E+10 | 0.501006E+11 | 0.00 | 0.00 | 0.00 | 34906015.81 | 0.419516E+09 |
November | 0.149361E+10 | 0.339663E+09 | 0.559104E+10 | 0.485726E+11 | 0.00 | 0.00 | 0.00 | 3902279.43 | 0.664111E+09 |
December | 0.154405E+10 | 0.349311E+09 | 0.575740E+10 | 0.500179E+11 | 0.00 | 0.00 | 0.00 | 512748.92 | 0.100110E+10 |
Annual Sum or Average | 0.182090E+11 | 0.412541E+10 | 0.679355E+11 | 0.590196E+12 | 0.00 | 0.00 | 0.00 | 0.131757E+10 | 0.548074E+10 |
Minimum of Months | 0.139600E+10 | 0.316249E+09 | 0.520895E+10 | 0.452532E+11 | 0.00 | 0.00 | 0.00 | 1113.09 | 1987511.29 |
Maximum of Months | 0.155131E+10 | 0.351471E+09 | 0.578252E+10 | 0.502361E+11 | 0.00 | 0.00 | 0.00 | 0.348708E+09 | 0.129250E+10 |
Report: SpaceGainsMonthly
For: CAFE_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.261570E+11 | 0.226040E+10 | 0.121771E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2720.50 | 0.224177E+10 |
February | 0.236489E+11 | 0.204093E+10 | 0.109956E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6204849.79 | 0.155384E+10 |
March | 0.262800E+11 | 0.226736E+10 | 0.122027E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27199821.81 | 0.962556E+09 |
April | 0.253579E+11 | 0.218376E+10 | 0.117692E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101215E+09 | 0.586568E+09 |
May | 0.262123E+11 | 0.226431E+10 | 0.121917E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.213680E+09 | 0.266747E+09 |
June | 0.254132E+11 | 0.219377E+10 | 0.118076E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.472101E+09 | 75695463.16 |
July | 0.261570E+11 | 0.225430E+10 | 0.121533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.581478E+09 | 25785450.25 |
August | 0.262677E+11 | 0.226823E+10 | 0.122063E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.605601E+09 | 3650366.18 |
September | 0.253456E+11 | 0.218463E+10 | 0.117729E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.267606E+09 | 0.134376E+09 |
October | 0.261693E+11 | 0.225952E+10 | 0.121734E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 58666826.37 | 0.716445E+09 |
November | 0.253025E+11 | 0.219203E+10 | 0.118021E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6480418.46 | 0.113965E+10 |
December | 0.261570E+11 | 0.225430E+10 | 0.121533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 738164.14 | 0.172845E+10 |
Annual Sum or Average | 0.308468E+12 | 0.266236E+11 | 0.143405E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.234097E+10 | 0.943553E+10 |
Minimum of Months | 0.236489E+11 | 0.204093E+10 | 0.109956E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2720.50 | 3650366.18 |
Maximum of Months | 0.262800E+11 | 0.226823E+10 | 0.122063E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.605601E+09 | 0.224177E+10 |
Report: SpaceGainsMonthly
For: LOBBY_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.776503E+11 | 0.123020E+11 | 0.126520E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 8641.18 | 0.641051E+10 |
February | 0.702046E+11 | 0.111075E+11 | 0.114244E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 21581756.22 | 0.444957E+10 |
March | 0.780153E+11 | 0.123399E+11 | 0.126786E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 82419904.34 | 0.277256E+10 |
April | 0.752779E+11 | 0.118849E+11 | 0.122282E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.294658E+09 | 0.170502E+10 |
May | 0.778146E+11 | 0.123233E+11 | 0.126672E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.607155E+09 | 0.792156E+09 |
June | 0.754422E+11 | 0.119394E+11 | 0.122682E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133820E+10 | 0.231664E+09 |
July | 0.776503E+11 | 0.122688E+11 | 0.126273E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.165297E+10 | 82750715.91 |
August | 0.779788E+11 | 0.123446E+11 | 0.126824E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.173679E+10 | 12385689.83 |
September | 0.752414E+11 | 0.118896E+11 | 0.122320E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.775938E+09 | 0.399230E+09 |
October | 0.776868E+11 | 0.122972E+11 | 0.126482E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.184908E+09 | 0.206151E+10 |
November | 0.751137E+11 | 0.119299E+11 | 0.122624E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 20303709.50 | 0.326211E+10 |
December | 0.776503E+11 | 0.122688E+11 | 0.126273E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 2609096.73 | 0.494517E+10 |
Annual Sum or Average | 0.915726E+12 | 0.144896E+12 | 0.148998E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.671754E+10 | 0.271246E+11 |
Minimum of Months | 0.702046E+11 | 0.111075E+11 | 0.114244E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 8641.18 | 12385689.83 |
Maximum of Months | 0.780153E+11 | 0.123446E+11 | 0.126824E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.173679E+10 | 0.641051E+10 |
Report: SpaceGainsMonthly
For: ROOM_1_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.303322E+09 | 0.434056E+09 | 0.261068E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.581627E+09 |
February | 0.273974E+09 | 0.391995E+09 | 0.235798E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 841395.47 | 0.405636E+09 |
March | 0.303685E+09 | 0.430607E+09 | 0.260708E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5259098.67 | 0.259506E+09 |
April | 0.293479E+09 | 0.420554E+09 | 0.252705E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 17938270.85 | 0.158437E+09 |
May | 0.303504E+09 | 0.432331E+09 | 0.260888E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 42368350.79 | 71521060.82 |
June | 0.293842E+09 | 0.417218E+09 | 0.252344E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109885E+09 | 18555800.86 |
July | 0.303141E+09 | 0.435725E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.141639E+09 | 7225275.88 |
August | 0.303685E+09 | 0.430607E+09 | 0.260708E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.150298E+09 | 891625.15 |
September | 0.293479E+09 | 0.420667E+09 | 0.252705E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 59346571.79 | 35142862.87 |
October | 0.303322E+09 | 0.434000E+09 | 0.261068E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11208609.59 | 0.192536E+09 |
November | 0.293661E+09 | 0.418886E+09 | 0.252524E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 742198.43 | 0.304418E+09 |
December | 0.303141E+09 | 0.435781E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 33481.42 | 0.451966E+09 |
Annual Sum or Average | 0.357224E+10 | 0.510243E+10 | 0.307301E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.539560E+09 | 0.248746E+10 |
Minimum of Months | 0.273974E+09 | 0.391995E+09 | 0.235798E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 891625.15 |
Maximum of Months | 0.303685E+09 | 0.435781E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.150298E+09 | 0.581627E+09 |
Report: SpaceGainsMonthly
For: ROOM_2_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.303322E+09 | 0.434005E+09 | 0.261038E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.575660E+09 |
February | 0.273974E+09 | 0.391949E+09 | 0.235770E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1133680.10 | 0.401142E+09 |
March | 0.303685E+09 | 0.430556E+09 | 0.260677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5509403.76 | 0.254309E+09 |
April | 0.293479E+09 | 0.420505E+09 | 0.252675E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 18710490.94 | 0.156983E+09 |
May | 0.303504E+09 | 0.432281E+09 | 0.260857E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 42643315.92 | 71279622.82 |
June | 0.293842E+09 | 0.417169E+09 | 0.252315E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109865E+09 | 18582264.99 |
July | 0.303141E+09 | 0.435674E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.141611E+09 | 7231320.28 |
August | 0.303685E+09 | 0.430556E+09 | 0.260677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.150380E+09 | 873896.71 |
September | 0.293479E+09 | 0.420618E+09 | 0.252675E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 59985018.65 | 34893472.03 |
October | 0.303322E+09 | 0.433949E+09 | 0.261038E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11962530.25 | 0.188048E+09 |
November | 0.293661E+09 | 0.418837E+09 | 0.252495E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 957021.35 | 0.297390E+09 |
December | 0.303141E+09 | 0.435730E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 92846.27 | 0.444031E+09 |
Annual Sum or Average | 0.357224E+10 | 0.510183E+10 | 0.307265E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.542850E+09 | 0.245042E+10 |
Minimum of Months | 0.273974E+09 | 0.391949E+09 | 0.235770E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 873896.71 |
Maximum of Months | 0.303685E+09 | 0.435730E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.150380E+09 | 0.575660E+09 |
Report: SpaceGainsMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.272788E+09 | 0.255708E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.162440E+09 |
February | 0.00 | 0.246354E+09 | 0.230956E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 94572.81 | 0.116550E+09 |
March | 0.00 | 0.270620E+09 | 0.255355E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 712527.02 | 86307797.97 |
April | 0.00 | 0.264302E+09 | 0.247516E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3263583.71 | 56724700.40 |
May | 0.00 | 0.271704E+09 | 0.255532E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 8274933.42 | 31093509.99 |
June | 0.00 | 0.262205E+09 | 0.247163E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 22958108.61 | 11359898.60 |
July | 0.00 | 0.273836E+09 | 0.255885E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 29662100.64 | 6500264.41 |
August | 0.00 | 0.270620E+09 | 0.255355E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 29600111.02 | 2101878.63 |
September | 0.00 | 0.264373E+09 | 0.247516E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 10549487.81 | 18056483.51 |
October | 0.00 | 0.272752E+09 | 0.255708E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1764153.25 | 67410547.22 |
November | 0.00 | 0.263254E+09 | 0.247340E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 28958.87 | 99496118.13 |
December | 0.00 | 0.273872E+09 | 0.255885E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.135441E+09 |
Annual Sum or Average | 0.00 | 0.320668E+10 | 0.300992E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.106909E+09 | 0.793482E+09 |
Minimum of Months | 0.00 | 0.246354E+09 | 0.230956E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2101878.63 |
Maximum of Months | 0.00 | 0.273872E+09 | 0.255885E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 29662100.64 | 0.162440E+09 |
Report: SpaceGainsMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.303322E+09 | 0.272862E+09 | 0.255778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.163166E+09 |
February | 0.273974E+09 | 0.246421E+09 | 0.231020E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 390169.73 | 0.113752E+09 |
March | 0.303685E+09 | 0.270694E+09 | 0.255425E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1713819.50 | 71811185.65 |
April | 0.293479E+09 | 0.264375E+09 | 0.247584E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5803192.33 | 43994807.45 |
May | 0.303504E+09 | 0.271778E+09 | 0.255602E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12587204.58 | 19792359.11 |
June | 0.293842E+09 | 0.262277E+09 | 0.247231E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 31128666.45 | 5155885.35 |
July | 0.303141E+09 | 0.273911E+09 | 0.255955E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 39898701.22 | 1968330.06 |
August | 0.303685E+09 | 0.270694E+09 | 0.255425E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 42483991.75 | 223726.61 |
September | 0.293479E+09 | 0.264446E+09 | 0.247584E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 17520461.75 | 9803773.42 |
October | 0.303322E+09 | 0.272827E+09 | 0.255778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3722853.60 | 53186204.31 |
November | 0.293661E+09 | 0.263326E+09 | 0.247408E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 311346.43 | 84298294.39 |
December | 0.303141E+09 | 0.273947E+09 | 0.255955E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 39175.24 | 0.126662E+09 |
Annual Sum or Average | 0.357224E+10 | 0.320756E+10 | 0.301074E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.155600E+09 | 0.693815E+09 |
Minimum of Months | 0.273974E+09 | 0.246421E+09 | 0.231020E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 223726.61 |
Maximum of Months | 0.303685E+09 | 0.273947E+09 | 0.255955E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 42483991.75 | 0.163166E+09 |
Report: SpaceGainsMonthly
For: ROOM_5_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.303322E+09 | 0.434056E+09 | 0.261068E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.582535E+09 |
February | 0.273974E+09 | 0.391995E+09 | 0.235798E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 827796.26 | 0.407291E+09 |
March | 0.303685E+09 | 0.430607E+09 | 0.260708E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5325099.34 | 0.262282E+09 |
April | 0.293479E+09 | 0.420554E+09 | 0.252705E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 17827085.42 | 0.160897E+09 |
May | 0.303504E+09 | 0.432331E+09 | 0.260888E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 41988140.30 | 72893205.66 |
June | 0.293842E+09 | 0.417218E+09 | 0.252344E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109518E+09 | 19260450.96 |
July | 0.303141E+09 | 0.435725E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.141240E+09 | 7445510.68 |
August | 0.303685E+09 | 0.430607E+09 | 0.260708E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.149924E+09 | 989818.76 |
September | 0.293479E+09 | 0.420667E+09 | 0.252705E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 59179633.80 | 35737057.47 |
October | 0.303322E+09 | 0.434000E+09 | 0.261068E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11169256.50 | 0.194228E+09 |
November | 0.293661E+09 | 0.418886E+09 | 0.252524E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 793435.82 | 0.305727E+09 |
December | 0.303141E+09 | 0.435781E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 33560.68 | 0.452782E+09 |
Annual Sum or Average | 0.357224E+10 | 0.510243E+10 | 0.307301E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.537825E+09 | 0.250207E+10 |
Minimum of Months | 0.273974E+09 | 0.391995E+09 | 0.235798E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 989818.76 |
Maximum of Months | 0.303685E+09 | 0.435781E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.149924E+09 | 0.582535E+09 |
Report: SpaceGainsMonthly
For: ROOM_6_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.303322E+09 | 0.434005E+09 | 0.261038E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.576061E+09 |
February | 0.273974E+09 | 0.391949E+09 | 0.235770E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1040415.32 | 0.402447E+09 |
March | 0.303685E+09 | 0.430556E+09 | 0.260677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5661832.79 | 0.257163E+09 |
April | 0.293479E+09 | 0.420505E+09 | 0.252675E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 18004176.50 | 0.159565E+09 |
May | 0.303504E+09 | 0.432281E+09 | 0.260857E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 42020414.43 | 72721449.27 |
June | 0.293842E+09 | 0.417169E+09 | 0.252315E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109503E+09 | 19279673.91 |
July | 0.303141E+09 | 0.435674E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.141227E+09 | 7438266.06 |
August | 0.303685E+09 | 0.430556E+09 | 0.260677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.149956E+09 | 976202.00 |
September | 0.293479E+09 | 0.420618E+09 | 0.252675E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 59335423.71 | 35578127.27 |
October | 0.303322E+09 | 0.433949E+09 | 0.261038E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11498526.51 | 0.190208E+09 |
November | 0.293661E+09 | 0.418837E+09 | 0.252495E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1104527.17 | 0.297916E+09 |
December | 0.303141E+09 | 0.435730E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 133846.84 | 0.444458E+09 |
Annual Sum or Average | 0.357224E+10 | 0.510183E+10 | 0.307265E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.539486E+09 | 0.246381E+10 |
Minimum of Months | 0.273974E+09 | 0.391949E+09 | 0.235770E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 976202.00 |
Maximum of Months | 0.303685E+09 | 0.435730E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.149956E+09 | 0.576061E+09 |
Report: SpaceGainsMonthly
For: CORRIDOR_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.385223E+10 | 0.133160E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 466.88 | 0.712859E+09 |
February | 0.348285E+10 | 0.120231E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2290185.28 | 0.493608E+09 |
March | 0.387034E+10 | 0.133570E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9073992.39 | 0.304748E+09 |
April | 0.373454E+10 | 0.128645E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31324996.62 | 0.186438E+09 |
May | 0.386038E+10 | 0.133391E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 64213498.73 | 86024506.79 |
June | 0.374269E+10 | 0.129235E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.135963E+09 | 27083803.13 |
July | 0.385223E+10 | 0.132801E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.165139E+09 | 11245858.40 |
August | 0.386853E+10 | 0.133622E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.171767E+09 | 2123446.46 |
September | 0.373273E+10 | 0.128696E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 78005840.06 | 44843109.90 |
October | 0.385404E+10 | 0.133109E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19688265.63 | 0.226001E+09 |
November | 0.372639E+10 | 0.129132E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2196758.04 | 0.359846E+09 |
December | 0.385223E+10 | 0.132801E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 274674.17 | 0.548943E+09 |
Annual Sum or Average | 0.454292E+11 | 0.156839E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.679938E+09 | 0.300376E+10 |
Minimum of Months | 0.348285E+10 | 0.120231E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 466.88 | 2123446.46 |
Maximum of Months | 0.387034E+10 | 0.133622E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.171767E+09 | 0.712859E+09 |
Report: SpaceGainsMonthly
For: ROOM_1_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.303322E+09 | 0.434056E+09 | 0.261068E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.580438E+09 |
February | 0.273974E+09 | 0.391995E+09 | 0.235798E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 800789.39 | 0.405353E+09 |
March | 0.303685E+09 | 0.430607E+09 | 0.260708E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5094400.37 | 0.260102E+09 |
April | 0.293479E+09 | 0.420554E+09 | 0.252705E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 17355037.35 | 0.159701E+09 |
May | 0.303504E+09 | 0.432331E+09 | 0.260888E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 41345532.65 | 72857003.28 |
June | 0.293842E+09 | 0.417218E+09 | 0.252344E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108399E+09 | 19083061.52 |
July | 0.303141E+09 | 0.435725E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.139936E+09 | 7589523.06 |
August | 0.303685E+09 | 0.430607E+09 | 0.260708E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.148384E+09 | 961248.98 |
September | 0.293479E+09 | 0.420667E+09 | 0.252705E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 58077857.66 | 35779888.36 |
October | 0.303322E+09 | 0.434000E+09 | 0.261068E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 10840978.06 | 0.193207E+09 |
November | 0.293661E+09 | 0.418886E+09 | 0.252524E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 676892.63 | 0.304368E+09 |
December | 0.303141E+09 | 0.435781E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 30299.65 | 0.450393E+09 |
Annual Sum or Average | 0.357224E+10 | 0.510243E+10 | 0.307301E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.530941E+09 | 0.248983E+10 |
Minimum of Months | 0.273974E+09 | 0.391995E+09 | 0.235798E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 961248.98 |
Maximum of Months | 0.303685E+09 | 0.435781E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.148384E+09 | 0.580438E+09 |
Report: SpaceGainsMonthly
For: ROOM_2_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.303322E+09 | 0.434005E+09 | 0.261038E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.576232E+09 |
February | 0.273974E+09 | 0.391949E+09 | 0.235770E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1078538.15 | 0.401640E+09 |
March | 0.303685E+09 | 0.430556E+09 | 0.260677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5268458.63 | 0.254880E+09 |
April | 0.293479E+09 | 0.420505E+09 | 0.252675E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 17786933.54 | 0.158269E+09 |
May | 0.303504E+09 | 0.432281E+09 | 0.260857E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 41428989.64 | 72653428.60 |
June | 0.293842E+09 | 0.417169E+09 | 0.252315E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108369E+09 | 19120617.89 |
July | 0.303141E+09 | 0.435674E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.139904E+09 | 7596017.20 |
August | 0.303685E+09 | 0.430556E+09 | 0.260677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.148450E+09 | 943498.83 |
September | 0.293479E+09 | 0.420618E+09 | 0.252675E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 58428874.64 | 35515222.22 |
October | 0.303322E+09 | 0.433949E+09 | 0.261038E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11358901.39 | 0.188706E+09 |
November | 0.293661E+09 | 0.418837E+09 | 0.252495E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 902419.16 | 0.297215E+09 |
December | 0.303141E+09 | 0.435730E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 86009.04 | 0.443214E+09 |
Annual Sum or Average | 0.357224E+10 | 0.510183E+10 | 0.307265E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.533062E+09 | 0.245599E+10 |
Minimum of Months | 0.273974E+09 | 0.391949E+09 | 0.235770E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 943498.83 |
Maximum of Months | 0.303685E+09 | 0.435730E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.148450E+09 | 0.576232E+09 |
Report: SpaceGainsMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.303322E+09 | 0.272862E+09 | 0.255778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.304796E+09 |
February | 0.273974E+09 | 0.246421E+09 | 0.231020E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 401145.86 | 0.212489E+09 |
March | 0.303685E+09 | 0.270694E+09 | 0.255425E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2604671.88 | 0.135946E+09 |
April | 0.293479E+09 | 0.264375E+09 | 0.247584E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 8866664.54 | 82610013.55 |
May | 0.303504E+09 | 0.271778E+09 | 0.255602E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 21218658.99 | 37311432.49 |
June | 0.293842E+09 | 0.262277E+09 | 0.247231E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 55578436.27 | 9751429.91 |
July | 0.303141E+09 | 0.273911E+09 | 0.255955E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 71684339.42 | 3871088.45 |
August | 0.303685E+09 | 0.270694E+09 | 0.255425E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 75958086.96 | 487725.80 |
September | 0.293479E+09 | 0.264446E+09 | 0.247584E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 29674730.67 | 18520752.45 |
October | 0.303322E+09 | 0.272827E+09 | 0.255778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5483189.69 | 0.101086E+09 |
November | 0.293661E+09 | 0.263326E+09 | 0.247408E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 334598.01 | 0.160314E+09 |
December | 0.303141E+09 | 0.273947E+09 | 0.255955E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 15274.58 | 0.237902E+09 |
Annual Sum or Average | 0.357224E+10 | 0.320756E+10 | 0.301074E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.271820E+09 | 0.130509E+10 |
Minimum of Months | 0.273974E+09 | 0.246421E+09 | 0.231020E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 487725.80 |
Maximum of Months | 0.303685E+09 | 0.273947E+09 | 0.255955E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 75958086.96 | 0.304796E+09 |
Report: SpaceGainsMonthly
For: BANQUET_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.459349E+11 | 0.396945E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.146274E+10 |
February | 0.415303E+11 | 0.358405E+10 | 0.134904E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 4435288.78 | 0.102406E+10 |
March | 0.461508E+11 | 0.398168E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 16307942.28 | 0.654844E+09 |
April | 0.445315E+11 | 0.383486E+10 | 0.144540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 60774532.67 | 0.414669E+09 |
May | 0.460320E+11 | 0.397633E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124701E+09 | 0.209215E+09 |
June | 0.446286E+11 | 0.385245E+10 | 0.144540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.273485E+09 | 70200335.59 |
July | 0.459349E+11 | 0.395874E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.335510E+09 | 30198055.05 |
August | 0.461292E+11 | 0.398321E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.349130E+09 | 6895915.49 |
September | 0.445099E+11 | 0.383639E+10 | 0.144540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.155399E+09 | 0.108418E+09 |
October | 0.459565E+11 | 0.396792E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 38049895.30 | 0.493075E+09 |
November | 0.444343E+11 | 0.384939E+10 | 0.144540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 3881180.47 | 0.761554E+09 |
December | 0.459349E+11 | 0.395874E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 479797.62 | 0.113710E+10 |
Annual Sum or Average | 0.541708E+12 | 0.467532E+11 | 0.175857E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.136215E+10 | 0.637298E+10 |
Minimum of Months | 0.415303E+11 | 0.358405E+10 | 0.134904E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6895915.49 |
Maximum of Months | 0.461508E+11 | 0.398321E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.349130E+09 | 0.146274E+10 |
Report: SpaceGainsMonthly
For: DINING_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.459349E+11 | 0.396945E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.146553E+10 |
February | 0.415303E+11 | 0.358405E+10 | 0.134904E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 4344754.50 | 0.102699E+10 |
March | 0.461508E+11 | 0.398168E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 15818098.46 | 0.658593E+09 |
April | 0.445315E+11 | 0.383486E+10 | 0.144540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 59445819.41 | 0.418438E+09 |
May | 0.460320E+11 | 0.397633E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121995E+09 | 0.212708E+09 |
June | 0.446286E+11 | 0.385245E+10 | 0.144540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.268922E+09 | 71948586.41 |
July | 0.459349E+11 | 0.395874E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.330903E+09 | 31419140.23 |
August | 0.461292E+11 | 0.398321E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.344032E+09 | 7314822.59 |
September | 0.445099E+11 | 0.383639E+10 | 0.144540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.152154E+09 | 0.110747E+09 |
October | 0.459565E+11 | 0.396792E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 37398118.69 | 0.496806E+09 |
November | 0.444343E+11 | 0.384939E+10 | 0.144540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 3798844.49 | 0.765015E+09 |
December | 0.459349E+11 | 0.395874E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 465196.55 | 0.114030E+10 |
Annual Sum or Average | 0.541708E+12 | 0.467532E+11 | 0.175857E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133928E+10 | 0.640581E+10 |
Minimum of Months | 0.415303E+11 | 0.358405E+10 | 0.134904E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7314822.59 |
Maximum of Months | 0.461508E+11 | 0.398321E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.344032E+09 | 0.146553E+10 |
Report: SpaceGainsMonthly
For: KITCHEN_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.408770E+10 | 0.105977E+10 | 0.338870E+11 | 0.305408E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.140365E+10 |
February | 0.369574E+10 | 0.956878E+09 | 0.306077E+11 | 0.275852E+11 | 0.00 | 0.00 | 0.00 | 376786.20 | 0.999535E+09 |
March | 0.410691E+10 | 0.106304E+10 | 0.338870E+11 | 0.305408E+11 | 0.00 | 0.00 | 0.00 | 3524620.49 | 0.672129E+09 |
April | 0.396281E+10 | 0.102384E+10 | 0.327939E+11 | 0.295556E+11 | 0.00 | 0.00 | 0.00 | 18305093.56 | 0.428429E+09 |
May | 0.409635E+10 | 0.106161E+10 | 0.338870E+11 | 0.305408E+11 | 0.00 | 0.00 | 0.00 | 51186091.58 | 0.218943E+09 |
June | 0.397146E+10 | 0.102854E+10 | 0.327939E+11 | 0.295556E+11 | 0.00 | 0.00 | 0.00 | 0.166109E+09 | 66002049.24 |
July | 0.408770E+10 | 0.105691E+10 | 0.338870E+11 | 0.305408E+11 | 0.00 | 0.00 | 0.00 | 0.226723E+09 | 35863561.51 |
August | 0.410499E+10 | 0.106345E+10 | 0.338870E+11 | 0.305408E+11 | 0.00 | 0.00 | 0.00 | 0.234422E+09 | 10341120.33 |
September | 0.396089E+10 | 0.102425E+10 | 0.327939E+11 | 0.295556E+11 | 0.00 | 0.00 | 0.00 | 74577563.82 | 0.121232E+09 |
October | 0.408962E+10 | 0.105936E+10 | 0.338870E+11 | 0.305408E+11 | 0.00 | 0.00 | 0.00 | 10112216.85 | 0.514818E+09 |
November | 0.395417E+10 | 0.102772E+10 | 0.327939E+11 | 0.295556E+11 | 0.00 | 0.00 | 0.00 | 91939.29 | 0.773370E+09 |
December | 0.408770E+10 | 0.105691E+10 | 0.338870E+11 | 0.305408E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.111423E+10 |
Annual Sum or Average | 0.482060E+11 | 0.124823E+11 | 0.398993E+12 | 0.359593E+12 | 0.00 | 0.00 | 0.00 | 0.785428E+09 | 0.635855E+10 |
Minimum of Months | 0.369574E+10 | 0.956878E+09 | 0.306077E+11 | 0.275852E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 10341120.33 |
Maximum of Months | 0.410691E+10 | 0.106345E+10 | 0.338870E+11 | 0.305408E+11 | 0.00 | 0.00 | 0.00 | 0.234422E+09 | 0.140365E+10 |
Report: SpaceGainsMonthly
For: CORRIDOR_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.407704E+10 | 0.140929E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.126530E+10 |
February | 0.368610E+10 | 0.127246E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4006345.95 | 0.876107E+09 |
March | 0.409620E+10 | 0.141364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16287036.68 | 0.541394E+09 |
April | 0.395248E+10 | 0.136151E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 55140307.51 | 0.327580E+09 |
May | 0.408566E+10 | 0.141173E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.115414E+09 | 0.144402E+09 |
June | 0.396110E+10 | 0.136775E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.258085E+09 | 38009495.55 |
July | 0.407704E+10 | 0.140549E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.315779E+09 | 12849650.73 |
August | 0.409429E+10 | 0.141418E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.335079E+09 | 1229741.14 |
September | 0.395056E+10 | 0.136205E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.154064E+09 | 71071830.85 |
October | 0.407896E+10 | 0.140875E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35621624.04 | 0.399172E+09 |
November | 0.394385E+10 | 0.136667E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3687814.46 | 0.640251E+09 |
December | 0.407704E+10 | 0.140549E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 450942.45 | 0.975607E+09 |
Annual Sum or Average | 0.480803E+11 | 0.165990E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.129362E+10 | 0.529297E+10 |
Minimum of Months | 0.368610E+10 | 0.127246E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1229741.14 |
Maximum of Months | 0.409620E+10 | 0.141418E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.335079E+09 | 0.126530E+10 |
Report: PeakSpaceGainsMonthly
For: BASEMENT
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 11501.89 | 02-JAN-00:10 | 13517.00 | 02-JAN-20:10 | 10113.80 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 11501.89 | 01-FEB-00:10 | 13517.00 | 01-FEB-20:10 | 10113.80 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 11501.89 | 01-MAR-00:10 | 13517.00 | 01-MAR-20:10 | 10113.80 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 11501.89 | 01-APR-00:10 | 13517.00 | 03-APR-19:10 | 10113.80 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 11501.89 | 01-MAY-00:10 | 13517.00 | 01-MAY-19:10 | 10113.80 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 11501.89 | 01-JUN-00:10 | 13517.00 | 01-JUN-19:10 | 10113.80 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 11501.89 | 01-JUL-00:10 | 13517.00 | 03-JUL-19:10 | 10113.80 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 11501.89 | 01-AUG-00:10 | 13517.00 | 01-AUG-19:10 | 10113.80 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 11501.89 | 01-SEP-00:10 | 13517.00 | 01-SEP-19:10 | 10113.80 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 11501.89 | 01-OCT-23:10 | 13517.00 | 02-OCT-19:10 | 10113.80 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 11501.89 | 01-NOV-00:10 | 13517.00 | 01-NOV-19:10 | 10113.80 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 11501.89 | 01-DEC-00:10 | 13517.00 | 01-DEC-20:10 | 10113.80 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 11501.89 | 13517.00 | 10113.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 11501.89 | 13517.00 | 10113.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: RETAIL_1_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1169.53 | 02-JAN-00:10 | 687.30 | 02-JAN-20:10 | 685.60 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1.97 | 31-JAN-15:00 | 637.16 | 27-JAN-08:00 |
February | 1169.53 | 01-FEB-00:10 | 687.30 | 01-FEB-20:10 | 685.60 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 78.13 | 28-FEB-14:40 | 771.69 | 12-FEB-07:00 |
March | 1169.53 | 01-MAR-00:10 | 687.30 | 01-MAR-20:10 | 685.60 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 123.15 | 30-MAR-16:00 | 443.24 | 19-MAR-07:00 |
April | 1169.53 | 01-APR-00:10 | 687.30 | 03-APR-19:10 | 685.60 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 151.88 | 17-APR-16:00 | 467.74 | 06-APR-05:00 |
May | 1169.53 | 01-MAY-00:10 | 687.30 | 01-MAY-19:10 | 685.60 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 191.85 | 19-MAY-16:30 | 285.14 | 11-MAY-06:00 |
June | 1169.53 | 01-JUN-00:10 | 687.30 | 01-JUN-19:10 | 685.60 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 251.25 | 06-JUN-15:00 | 211.45 | 10-JUN-05:00 |
July | 1169.53 | 01-JUL-00:10 | 687.30 | 03-JUL-19:10 | 685.60 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 296.57 | 08-JUL-16:00 | 80.04 | 28-JUL-23:30 |
August | 1169.53 | 01-AUG-00:10 | 687.30 | 01-AUG-19:10 | 685.60 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 269.33 | 01-AUG-17:00 | 56.11 | 25-AUG-06:00 |
September | 1169.53 | 01-SEP-00:10 | 687.30 | 01-SEP-19:10 | 685.60 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 193.81 | 07-SEP-16:00 | 198.14 | 29-SEP-04:00 |
October | 1169.53 | 01-OCT-23:10 | 687.30 | 02-OCT-19:10 | 685.60 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 155.28 | 10-OCT-16:00 | 415.55 | 26-OCT-07:00 |
November | 1169.53 | 01-NOV-00:10 | 687.30 | 01-NOV-19:10 | 685.60 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 67.01 | 19-NOV-15:00 | 546.18 | 22-NOV-06:20 |
December | 1169.53 | 01-DEC-00:10 | 687.30 | 01-DEC-20:10 | 685.60 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.35 | 12-DEC-15:30 | 608.82 | 18-DEC-08:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1169.53 | 687.30 | 685.60 | 0.00 | 0.00 | 0.00 | 0.00 | 1.97 | 56.11 | |||||
Maximum of Months | 1169.53 | 687.30 | 685.60 | 0.00 | 0.00 | 0.00 | 0.00 | 296.57 | 771.69 |
Report: PeakSpaceGainsMonthly
For: RETAIL_2_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1354.32 | 02-JAN-00:10 | 795.89 | 02-JAN-20:10 | 793.93 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.75 | 31-JAN-15:00 | 246.53 | 27-JAN-08:00 |
February | 1354.32 | 01-FEB-00:10 | 795.89 | 01-FEB-20:10 | 793.93 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 31.38 | 28-FEB-14:00 | 309.37 | 12-FEB-07:00 |
March | 1354.32 | 01-MAR-00:10 | 795.89 | 01-MAR-20:10 | 793.93 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 52.74 | 30-MAR-14:10 | 171.09 | 19-MAR-07:00 |
April | 1354.32 | 01-APR-00:10 | 795.89 | 03-APR-19:10 | 793.93 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 61.90 | 12-APR-14:00 | 180.55 | 06-APR-05:00 |
May | 1354.32 | 01-MAY-00:10 | 795.89 | 01-MAY-19:10 | 793.93 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 74.13 | 19-MAY-14:00 | 110.09 | 11-MAY-06:00 |
June | 1354.32 | 01-JUN-00:10 | 795.89 | 01-JUN-19:10 | 793.93 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 100.87 | 06-JUN-15:00 | 81.62 | 10-JUN-05:00 |
July | 1354.32 | 01-JUL-00:10 | 795.89 | 03-JUL-19:10 | 793.93 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 118.65 | 08-JUL-15:00 | 33.47 | 28-JUL-22:53 |
August | 1354.32 | 01-AUG-00:10 | 795.89 | 01-AUG-19:10 | 793.93 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 106.79 | 02-AUG-16:00 | 23.64 | 25-AUG-06:00 |
September | 1354.32 | 01-SEP-00:10 | 795.89 | 01-SEP-19:10 | 793.93 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 81.88 | 07-SEP-15:40 | 76.49 | 29-SEP-04:00 |
October | 1354.32 | 01-OCT-23:10 | 795.89 | 02-OCT-19:10 | 793.93 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 69.33 | 10-OCT-16:00 | 160.41 | 26-OCT-07:00 |
November | 1354.32 | 01-NOV-00:10 | 795.89 | 01-NOV-19:10 | 793.93 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.69 | 05-NOV-16:00 | 210.83 | 22-NOV-06:30 |
December | 1354.32 | 01-DEC-00:10 | 795.89 | 01-DEC-20:10 | 793.93 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.32 | 12-DEC-14:30 | 235.07 | 18-DEC-08:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1354.32 | 795.89 | 793.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.75 | 23.64 | |||||
Maximum of Months | 1354.32 | 795.89 | 793.93 | 0.00 | 0.00 | 0.00 | 0.00 | 118.65 | 309.37 |
Report: PeakSpaceGainsMonthly
For: MECH_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 286.42 | 02-JAN-00:10 | 1487.69 | 02-JAN-20:10 | 839.45 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1.81 | 31-JAN-15:00 | 582.65 | 27-JAN-08:00 |
February | 286.42 | 01-FEB-00:10 | 1487.69 | 01-FEB-20:10 | 839.45 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 74.17 | 26-FEB-15:00 | 727.18 | 12-FEB-07:00 |
March | 286.42 | 01-MAR-00:10 | 1487.69 | 01-MAR-20:10 | 839.45 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 124.63 | 30-MAR-14:10 | 404.34 | 19-MAR-07:00 |
April | 286.42 | 01-APR-00:10 | 1487.69 | 03-APR-19:10 | 839.45 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 146.27 | 12-APR-14:00 | 426.72 | 06-APR-05:00 |
May | 286.42 | 01-MAY-00:10 | 1487.69 | 01-MAY-19:10 | 839.45 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 175.23 | 19-MAY-14:00 | 260.08 | 11-MAY-06:00 |
June | 286.42 | 01-JUN-00:10 | 1487.69 | 01-JUN-19:10 | 839.45 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 238.36 | 06-JUN-15:00 | 192.89 | 10-JUN-05:00 |
July | 286.42 | 01-JUL-00:10 | 1487.69 | 03-JUL-19:10 | 839.45 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 280.38 | 08-JUL-15:08 | 73.23 | 28-JUL-22:53 |
August | 286.42 | 01-AUG-00:10 | 1487.69 | 01-AUG-19:10 | 839.45 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 252.41 | 02-AUG-16:00 | 51.57 | 25-AUG-06:00 |
September | 286.42 | 01-SEP-00:10 | 1487.69 | 01-SEP-19:10 | 839.45 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 193.51 | 07-SEP-15:50 | 180.71 | 29-SEP-04:00 |
October | 286.42 | 01-OCT-23:10 | 1487.69 | 02-OCT-19:10 | 839.45 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 163.84 | 10-OCT-16:00 | 379.08 | 26-OCT-07:00 |
November | 286.42 | 01-NOV-00:10 | 1487.69 | 01-NOV-19:10 | 839.45 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 63.05 | 05-NOV-16:00 | 498.25 | 22-NOV-06:10 |
December | 286.42 | 01-DEC-00:10 | 1487.69 | 01-DEC-20:10 | 839.45 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 33.83 | 12-DEC-14:10 | 555.54 | 18-DEC-08:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 286.42 | 1487.69 | 839.45 | 0.00 | 0.00 | 0.00 | 0.00 | 1.81 | 51.57 | |||||
Maximum of Months | 286.42 | 1487.69 | 839.45 | 0.00 | 0.00 | 0.00 | 0.00 | 280.38 | 727.18 |
Report: PeakSpaceGainsMonthly
For: STORAGE_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 220.32 | 02-JAN-00:10 | 273.10 | 02-JAN-20:10 | 242.16 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1.06 | 31-JAN-15:00 | 335.29 | 14-JAN-07:00 |
February | 220.32 | 01-FEB-00:10 | 273.10 | 01-FEB-20:10 | 242.16 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 42.80 | 26-FEB-15:00 | 416.45 | 12-FEB-07:00 |
March | 220.32 | 01-MAR-00:10 | 273.10 | 01-MAR-20:10 | 242.16 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 71.90 | 30-MAR-15:50 | 233.26 | 19-MAR-07:00 |
April | 220.32 | 01-APR-00:10 | 273.10 | 03-APR-19:10 | 242.16 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 84.40 | 12-APR-14:00 | 246.19 | 06-APR-05:00 |
May | 220.32 | 01-MAY-00:10 | 273.10 | 01-MAY-19:10 | 242.16 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 101.09 | 19-MAY-14:00 | 150.07 | 11-MAY-06:00 |
June | 220.32 | 01-JUN-00:10 | 273.10 | 01-JUN-19:10 | 242.16 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 137.52 | 06-JUN-15:00 | 111.29 | 10-JUN-05:00 |
July | 220.32 | 01-JUL-00:10 | 273.10 | 03-JUL-19:10 | 242.16 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 161.66 | 08-JUL-15:50 | 42.08 | 28-JUL-24:00 |
August | 220.32 | 01-AUG-00:10 | 273.10 | 01-AUG-19:10 | 242.16 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 145.64 | 02-AUG-16:00 | 29.53 | 25-AUG-06:00 |
September | 220.32 | 01-SEP-00:10 | 273.10 | 01-SEP-19:10 | 242.16 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 111.65 | 07-SEP-16:00 | 104.26 | 29-SEP-04:00 |
October | 220.32 | 01-OCT-23:10 | 273.10 | 02-OCT-19:10 | 242.16 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 94.54 | 10-OCT-16:00 | 218.73 | 26-OCT-07:00 |
November | 220.32 | 01-NOV-00:10 | 273.10 | 01-NOV-19:10 | 242.16 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 36.40 | 05-NOV-16:00 | 287.46 | 22-NOV-06:10 |
December | 220.32 | 01-DEC-00:10 | 273.10 | 01-DEC-20:10 | 242.16 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.52 | 12-DEC-14:10 | 320.52 | 18-DEC-08:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 220.32 | 273.10 | 242.16 | 0.00 | 0.00 | 0.00 | 0.00 | 1.06 | 29.53 | |||||
Maximum of Months | 220.32 | 273.10 | 242.16 | 0.00 | 0.00 | 0.00 | 0.00 | 161.66 | 416.45 |
Report: PeakSpaceGainsMonthly
For: LAUNDRY_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 907.20 | 02-JAN-00:10 | 337.37 | 02-JAN-20:10 | 4572.80 | 02-JAN-20:10 | 39726.58 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 1.86 | 31-JAN-15:00 | 824.76 | 07-JAN-22:00 |
February | 907.20 | 01-FEB-00:10 | 337.37 | 01-FEB-20:10 | 4572.80 | 01-FEB-20:10 | 39726.58 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 101.41 | 26-FEB-15:00 | 998.39 | 12-FEB-07:00 |
March | 907.20 | 01-MAR-00:10 | 337.37 | 01-MAR-20:10 | 4572.80 | 01-MAR-20:10 | 39726.58 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 170.38 | 30-MAR-15:30 | 552.36 | 19-MAR-07:00 |
April | 907.20 | 01-APR-00:10 | 337.37 | 03-APR-19:10 | 4572.80 | 03-APR-19:10 | 39726.58 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 199.58 | 12-APR-14:00 | 582.98 | 06-APR-05:00 |
May | 907.20 | 01-MAY-00:10 | 337.37 | 01-MAY-19:10 | 4572.80 | 01-MAY-19:10 | 39726.58 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 239.39 | 19-MAY-14:10 | 355.06 | 11-MAY-06:00 |
June | 907.20 | 01-JUN-00:10 | 337.37 | 01-JUN-19:10 | 4572.80 | 01-JUN-19:10 | 39726.58 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 325.18 | 06-JUN-15:00 | 263.09 | 10-JUN-05:00 |
July | 907.20 | 01-JUL-00:10 | 337.37 | 03-JUL-19:10 | 4572.80 | 03-JUL-19:10 | 39726.58 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 383.03 | 08-JUL-15:20 | 148.86 | 28-JUL-21:00 |
August | 907.20 | 01-AUG-00:10 | 337.37 | 01-AUG-19:10 | 4572.80 | 01-AUG-19:10 | 39726.58 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 344.61 | 02-AUG-16:00 | 80.70 | 25-AUG-06:10 |
September | 907.20 | 01-SEP-00:10 | 337.37 | 01-SEP-19:10 | 4572.80 | 01-SEP-19:10 | 39726.58 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 264.34 | 07-SEP-15:00 | 246.65 | 29-SEP-04:00 |
October | 907.20 | 01-OCT-23:10 | 337.37 | 02-OCT-19:10 | 4572.80 | 02-OCT-19:10 | 39726.58 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 223.88 | 10-OCT-16:00 | 527.63 | 26-OCT-07:00 |
November | 907.20 | 01-NOV-00:10 | 337.37 | 01-NOV-19:10 | 4572.80 | 01-NOV-19:10 | 39726.58 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 86.24 | 05-NOV-16:00 | 680.58 | 22-NOV-06:00 |
December | 907.20 | 01-DEC-00:10 | 337.37 | 01-DEC-20:10 | 4572.80 | 01-DEC-20:10 | 39726.58 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 46.25 | 12-DEC-14:55 | 764.03 | 18-DEC-08:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 907.20 | 337.37 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 1.86 | 80.70 | ||||||
Maximum of Months | 907.20 | 337.37 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 383.03 | 998.39 |
Report: PeakSpaceGainsMonthly
For: CAFE_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 15368.40 | 02-JAN-00:10 | 2177.23 | 02-JAN-20:10 | 965.27 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4.25 | 31-JAN-15:00 | 1411.98 | 27-JAN-07:50 |
February | 15368.40 | 01-FEB-00:10 | 2177.23 | 01-FEB-20:10 | 965.27 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 179.55 | 28-FEB-14:20 | 1772.05 | 12-FEB-07:00 |
March | 15368.40 | 01-MAR-00:10 | 2177.23 | 01-MAR-20:10 | 965.27 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 277.31 | 30-MAR-16:00 | 980.02 | 19-MAR-07:00 |
April | 15368.40 | 01-APR-00:10 | 2177.23 | 03-APR-19:10 | 965.27 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 338.24 | 17-APR-16:00 | 1034.00 | 06-APR-05:00 |
May | 15368.40 | 01-MAY-00:10 | 2177.23 | 01-MAY-19:10 | 965.27 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 424.04 | 19-MAY-16:20 | 630.74 | 11-MAY-06:00 |
June | 15368.40 | 01-JUN-00:10 | 2177.23 | 01-JUN-19:10 | 965.27 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 573.64 | 06-JUN-15:00 | 469.18 | 10-JUN-05:00 |
July | 15368.40 | 01-JUL-00:10 | 2177.23 | 03-JUL-19:10 | 965.27 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 678.89 | 08-JUL-15:40 | 204.44 | 28-JUL-22:53 |
August | 15368.40 | 01-AUG-00:10 | 2177.23 | 01-AUG-19:10 | 965.27 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 606.20 | 01-AUG-17:00 | 133.13 | 25-AUG-06:00 |
September | 15368.40 | 01-SEP-00:10 | 2177.23 | 01-SEP-19:10 | 965.27 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 440.58 | 07-SEP-16:00 | 438.18 | 29-SEP-04:00 |
October | 15368.40 | 01-OCT-23:10 | 2177.23 | 02-OCT-19:10 | 965.27 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 354.65 | 10-OCT-16:00 | 919.01 | 26-OCT-07:00 |
November | 15368.40 | 01-NOV-00:10 | 2177.23 | 01-NOV-19:10 | 965.27 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 152.68 | 05-NOV-16:00 | 1207.73 | 22-NOV-06:40 |
December | 15368.40 | 01-DEC-00:10 | 2177.23 | 01-DEC-20:10 | 965.27 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 77.07 | 12-DEC-14:50 | 1346.55 | 18-DEC-08:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 15368.40 | 2177.23 | 965.27 | 0.00 | 0.00 | 0.00 | 0.00 | 4.25 | 133.13 | |||||
Maximum of Months | 15368.40 | 2177.23 | 965.27 | 0.00 | 0.00 | 0.00 | 0.00 | 678.89 | 1772.05 |
Report: PeakSpaceGainsMonthly
For: LOBBY_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 45622.98 | 02-JAN-00:10 | 11849.32 | 02-JAN-20:10 | 10029.21 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 12.68 | 31-JAN-15:00 | 4033.90 | 27-JAN-08:00 |
February | 45622.98 | 01-FEB-00:10 | 11849.32 | 01-FEB-20:10 | 10029.21 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 513.60 | 26-FEB-15:00 | 5062.58 | 12-FEB-07:00 |
March | 45622.98 | 01-MAR-00:10 | 11849.32 | 01-MAR-20:10 | 10029.21 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 862.76 | 30-MAR-15:40 | 2799.77 | 19-MAR-07:00 |
April | 45622.98 | 01-APR-00:10 | 11849.32 | 03-APR-19:10 | 10029.21 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1012.57 | 12-APR-14:00 | 2955.04 | 06-APR-05:00 |
May | 45622.98 | 01-MAY-00:10 | 11849.32 | 01-MAY-19:10 | 10029.21 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1213.15 | 19-MAY-14:00 | 1801.13 | 11-MAY-06:00 |
June | 45622.98 | 01-JUN-00:10 | 11849.32 | 01-JUN-19:10 | 10029.21 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1650.19 | 06-JUN-15:00 | 1388.60 | 10-JUN-05:00 |
July | 45622.98 | 01-JUL-00:10 | 11849.32 | 03-JUL-19:10 | 10029.21 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1941.62 | 08-JUL-15:00 | 616.17 | 28-JUL-22:53 |
August | 45622.98 | 01-AUG-00:10 | 11849.32 | 01-AUG-19:10 | 10029.21 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1747.78 | 02-AUG-16:00 | 432.27 | 25-AUG-06:00 |
September | 45622.98 | 01-SEP-00:10 | 11849.32 | 01-SEP-19:10 | 10029.21 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1339.68 | 07-SEP-16:00 | 1278.77 | 29-SEP-04:00 |
October | 45622.98 | 01-OCT-23:10 | 11849.32 | 02-OCT-19:10 | 10029.21 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1134.54 | 10-OCT-16:00 | 2624.56 | 26-OCT-07:00 |
November | 45622.98 | 01-NOV-00:10 | 11849.32 | 01-NOV-19:10 | 10029.21 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 436.54 | 05-NOV-16:00 | 3449.86 | 22-NOV-06:10 |
December | 45622.98 | 01-DEC-00:10 | 11849.32 | 01-DEC-20:10 | 10029.21 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 234.30 | 12-DEC-14:30 | 3846.72 | 18-DEC-08:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 45622.98 | 11849.32 | 10029.21 | 0.00 | 0.00 | 0.00 | 0.00 | 12.68 | 432.27 | |||||
Maximum of Months | 45622.98 | 11849.32 | 10029.21 | 0.00 | 0.00 | 0.00 | 0.00 | 1941.62 | 5062.58 |
Report: PeakSpaceGainsMonthly
For: ROOM_1_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 180.00 | 01-JAN-00:10 | 392.73 | 01-JAN-19:10 | 237.06 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 372.76 | 27-JAN-08:00 |
February | 180.00 | 01-FEB-00:10 | 392.73 | 01-FEB-20:10 | 237.06 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.40 | 26-FEB-16:08 | 467.29 | 12-FEB-07:00 |
March | 180.00 | 01-MAR-00:10 | 392.73 | 01-MAR-20:10 | 237.06 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 77.49 | 30-MAR-16:00 | 259.23 | 19-MAR-07:00 |
April | 180.00 | 01-APR-00:10 | 392.73 | 01-APR-18:10 | 237.06 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 90.31 | 17-APR-15:10 | 273.49 | 06-APR-05:00 |
May | 180.00 | 01-MAY-00:10 | 392.73 | 01-MAY-19:10 | 237.06 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 109.61 | 19-MAY-16:00 | 167.41 | 11-MAY-06:00 |
June | 180.00 | 01-JUN-00:10 | 392.73 | 01-JUN-19:10 | 237.06 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 148.98 | 06-JUN-15:10 | 124.63 | 10-JUN-05:00 |
July | 180.00 | 01-JUL-00:10 | 392.73 | 01-JUL-18:10 | 237.06 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 176.64 | 08-JUL-15:10 | 51.12 | 29-JUL-08:00 |
August | 180.00 | 01-AUG-00:10 | 392.73 | 01-AUG-19:10 | 237.06 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 158.84 | 02-AUG-16:00 | 34.40 | 25-AUG-06:00 |
September | 180.00 | 01-SEP-00:10 | 392.73 | 01-SEP-19:10 | 237.06 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 121.36 | 07-SEP-16:00 | 116.88 | 29-SEP-04:00 |
October | 180.00 | 01-OCT-00:10 | 392.73 | 01-OCT-18:10 | 237.06 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 102.48 | 10-OCT-16:00 | 243.16 | 26-OCT-07:00 |
November | 180.00 | 01-NOV-00:10 | 392.73 | 01-NOV-19:10 | 237.06 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.32 | 05-NOV-16:00 | 318.99 | 22-NOV-06:00 |
December | 180.00 | 01-DEC-00:10 | 392.73 | 01-DEC-20:10 | 237.06 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 11.51 | 12-DEC-16:08 | 355.48 | 18-DEC-08:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 180.00 | 392.73 | 237.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.40 | |||||
Maximum of Months | 180.00 | 392.73 | 237.06 | 0.00 | 0.00 | 0.00 | 0.00 | 176.64 | 467.29 |
Report: PeakSpaceGainsMonthly
For: ROOM_2_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 180.00 | 01-JAN-00:10 | 392.68 | 01-JAN-19:10 | 237.03 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 372.73 | 27-JAN-08:00 |
February | 180.00 | 01-FEB-00:10 | 392.68 | 01-FEB-20:10 | 237.03 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.40 | 26-FEB-16:08 | 467.25 | 12-FEB-07:00 |
March | 180.00 | 01-MAR-00:10 | 392.68 | 01-MAR-20:10 | 237.03 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 77.48 | 30-MAR-15:10 | 259.21 | 19-MAR-07:00 |
April | 180.00 | 01-APR-00:10 | 392.68 | 01-APR-18:10 | 237.03 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 90.30 | 17-APR-15:10 | 273.47 | 06-APR-05:00 |
May | 180.00 | 01-MAY-00:10 | 392.68 | 01-MAY-19:10 | 237.03 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 109.60 | 19-MAY-16:00 | 167.40 | 11-MAY-06:00 |
June | 180.00 | 01-JUN-00:10 | 392.68 | 01-JUN-19:10 | 237.03 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 148.97 | 06-JUN-15:10 | 124.62 | 10-JUN-05:00 |
July | 180.00 | 01-JUL-00:10 | 392.68 | 01-JUL-18:10 | 237.03 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 176.63 | 08-JUL-15:10 | 51.04 | 29-JUL-08:00 |
August | 180.00 | 01-AUG-00:10 | 392.68 | 01-AUG-19:10 | 237.03 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 158.83 | 02-AUG-16:00 | 34.40 | 25-AUG-06:00 |
September | 180.00 | 01-SEP-00:10 | 392.68 | 01-SEP-19:10 | 237.03 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 121.35 | 07-SEP-16:00 | 116.87 | 29-SEP-04:00 |
October | 180.00 | 01-OCT-00:10 | 392.68 | 01-OCT-18:10 | 237.03 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 102.46 | 10-OCT-16:00 | 243.13 | 26-OCT-07:00 |
November | 180.00 | 01-NOV-00:10 | 392.68 | 01-NOV-19:10 | 237.03 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.31 | 05-NOV-16:00 | 318.96 | 22-NOV-06:20 |
December | 180.00 | 01-DEC-00:10 | 392.68 | 01-DEC-20:10 | 237.03 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 11.51 | 12-DEC-16:05 | 355.44 | 18-DEC-08:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 180.00 | 392.68 | 237.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.40 | |||||
Maximum of Months | 180.00 | 392.68 | 237.03 | 0.00 | 0.00 | 0.00 | 0.00 | 176.63 | 467.25 |
Report: PeakSpaceGainsMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 01-JAN-00:10 | 246.81 | 01-JAN-19:10 | 232.19 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 100.60 | 27-JAN-08:00 |
February | 0.00 | 01-FEB-00:10 | 246.81 | 01-FEB-20:10 | 232.19 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 5.34 | 26-FEB-15:00 | 121.85 | 12-FEB-07:00 |
March | 0.00 | 01-MAR-00:10 | 246.81 | 01-MAR-20:10 | 232.19 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.39 | 30-MAR-14:00 | 74.28 | 19-MAR-07:00 |
April | 0.00 | 01-APR-00:10 | 246.81 | 01-APR-18:10 | 232.19 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.15 | 12-APR-14:00 | 76.49 | 06-APR-05:00 |
May | 0.00 | 01-MAY-00:10 | 246.81 | 01-MAY-19:10 | 232.19 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.40 | 19-MAY-14:00 | 52.20 | 11-MAY-06:00 |
June | 0.00 | 01-JUN-00:10 | 246.81 | 01-JUN-19:10 | 232.19 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 34.81 | 06-JUN-15:00 | 40.73 | 10-JUN-05:00 |
July | 0.00 | 01-JUL-00:10 | 246.81 | 01-JUL-18:10 | 232.19 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 42.25 | 08-JUL-15:00 | 21.03 | 28-JUL-23:10 |
August | 0.00 | 01-AUG-00:10 | 246.81 | 01-AUG-19:10 | 232.19 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.20 | 02-AUG-16:00 | 17.06 | 25-AUG-06:00 |
September | 0.00 | 01-SEP-00:10 | 246.81 | 01-SEP-19:10 | 232.19 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.72 | 07-SEP-16:00 | 38.36 | 14-SEP-06:00 |
October | 0.00 | 01-OCT-00:10 | 246.81 | 01-OCT-18:10 | 232.19 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 21.41 | 10-OCT-16:00 | 71.34 | 26-OCT-07:00 |
November | 0.00 | 01-NOV-00:10 | 246.81 | 01-NOV-19:10 | 232.19 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3.37 | 05-NOV-16:00 | 87.32 | 22-NOV-07:30 |
December | 0.00 | 01-DEC-00:10 | 246.81 | 01-DEC-20:10 | 232.19 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 98.40 | 18-DEC-08:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 0.00 | 246.81 | 232.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.06 | |||||
Maximum of Months | 0.00 | 246.81 | 232.19 | 0.00 | 0.00 | 0.00 | 0.00 | 42.25 | 121.85 |
Report: PeakSpaceGainsMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 180.00 | 01-JAN-00:10 | 246.88 | 01-JAN-19:10 | 232.26 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 104.03 | 27-JAN-08:00 |
February | 180.00 | 01-FEB-00:10 | 246.88 | 01-FEB-20:10 | 232.26 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10.44 | 26-FEB-16:08 | 130.41 | 12-FEB-07:00 |
March | 180.00 | 01-MAR-00:10 | 246.88 | 01-MAR-20:10 | 232.26 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 21.63 | 30-MAR-16:00 | 72.35 | 19-MAR-07:00 |
April | 180.00 | 01-APR-00:10 | 246.88 | 01-APR-18:10 | 232.26 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 25.20 | 17-APR-15:10 | 76.33 | 06-APR-05:00 |
May | 180.00 | 01-MAY-00:10 | 246.88 | 01-MAY-19:10 | 232.26 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.59 | 19-MAY-16:00 | 46.72 | 11-MAY-06:00 |
June | 180.00 | 01-JUN-00:10 | 246.88 | 01-JUN-19:10 | 232.26 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 41.58 | 06-JUN-15:10 | 34.78 | 10-JUN-05:00 |
July | 180.00 | 01-JUL-00:10 | 246.88 | 01-JUL-18:10 | 232.26 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 49.30 | 08-JUL-15:10 | 15.53 | 29-JUL-08:00 |
August | 180.00 | 01-AUG-00:10 | 246.88 | 01-AUG-19:10 | 232.26 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 44.33 | 02-AUG-16:00 | 9.60 | 25-AUG-06:00 |
September | 180.00 | 01-SEP-00:10 | 246.88 | 01-SEP-19:10 | 232.26 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 33.87 | 07-SEP-16:00 | 32.62 | 29-SEP-04:00 |
October | 180.00 | 01-OCT-00:10 | 246.88 | 01-OCT-18:10 | 232.26 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 28.60 | 10-OCT-16:00 | 67.86 | 26-OCT-07:00 |
November | 180.00 | 01-NOV-00:10 | 246.88 | 01-NOV-19:10 | 232.26 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10.69 | 05-NOV-16:00 | 89.02 | 22-NOV-06:40 |
December | 180.00 | 01-DEC-00:10 | 246.88 | 01-DEC-20:10 | 232.26 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3.98 | 12-DEC-14:00 | 99.21 | 18-DEC-08:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 180.00 | 246.88 | 232.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.60 | |||||
Maximum of Months | 180.00 | 246.88 | 232.26 | 0.00 | 0.00 | 0.00 | 0.00 | 49.30 | 130.41 |
Report: PeakSpaceGainsMonthly
For: ROOM_5_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 180.00 | 01-JAN-00:10 | 392.73 | 01-JAN-19:10 | 237.06 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 372.75 | 27-JAN-08:00 |
February | 180.00 | 01-FEB-00:10 | 392.73 | 01-FEB-20:10 | 237.06 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.40 | 26-FEB-16:08 | 467.27 | 12-FEB-07:00 |
March | 180.00 | 01-MAR-00:10 | 392.73 | 01-MAR-20:10 | 237.06 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 77.49 | 30-MAR-16:00 | 259.23 | 19-MAR-07:00 |
April | 180.00 | 01-APR-00:10 | 392.73 | 01-APR-18:10 | 237.06 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 90.31 | 17-APR-15:10 | 273.49 | 06-APR-05:00 |
May | 180.00 | 01-MAY-00:10 | 392.73 | 01-MAY-19:10 | 237.06 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 109.60 | 19-MAY-16:00 | 167.42 | 11-MAY-06:00 |
June | 180.00 | 01-JUN-00:10 | 392.73 | 01-JUN-19:10 | 237.06 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 148.98 | 06-JUN-15:10 | 124.63 | 10-JUN-05:00 |
July | 180.00 | 01-JUL-00:10 | 392.73 | 01-JUL-18:10 | 237.06 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 176.64 | 08-JUL-15:10 | 50.92 | 29-JUL-08:00 |
August | 180.00 | 01-AUG-00:10 | 392.73 | 01-AUG-19:10 | 237.06 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 158.84 | 02-AUG-16:00 | 34.40 | 25-AUG-06:00 |
September | 180.00 | 01-SEP-00:10 | 392.73 | 01-SEP-19:10 | 237.06 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 121.36 | 07-SEP-16:00 | 116.88 | 29-SEP-04:00 |
October | 180.00 | 01-OCT-00:10 | 392.73 | 01-OCT-18:10 | 237.06 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 102.46 | 10-OCT-16:00 | 243.16 | 26-OCT-07:00 |
November | 180.00 | 01-NOV-00:10 | 392.73 | 01-NOV-19:10 | 237.06 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.32 | 05-NOV-16:00 | 318.99 | 22-NOV-06:00 |
December | 180.00 | 01-DEC-00:10 | 392.73 | 01-DEC-20:10 | 237.06 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 11.51 | 12-DEC-16:08 | 355.48 | 18-DEC-08:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 180.00 | 392.73 | 237.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.40 | |||||
Maximum of Months | 180.00 | 392.73 | 237.06 | 0.00 | 0.00 | 0.00 | 0.00 | 176.64 | 467.27 |
Report: PeakSpaceGainsMonthly
For: ROOM_6_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 180.00 | 01-JAN-00:10 | 392.68 | 01-JAN-19:10 | 237.03 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 372.73 | 27-JAN-08:00 |
February | 180.00 | 01-FEB-00:10 | 392.68 | 01-FEB-20:10 | 237.03 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.40 | 26-FEB-16:08 | 467.24 | 12-FEB-07:00 |
March | 180.00 | 01-MAR-00:10 | 392.68 | 01-MAR-20:10 | 237.03 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 77.48 | 30-MAR-16:00 | 259.21 | 19-MAR-07:00 |
April | 180.00 | 01-APR-00:10 | 392.68 | 01-APR-18:10 | 237.03 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 90.30 | 17-APR-15:10 | 273.46 | 06-APR-05:00 |
May | 180.00 | 01-MAY-00:10 | 392.68 | 01-MAY-19:10 | 237.03 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 109.59 | 19-MAY-16:00 | 167.40 | 11-MAY-06:00 |
June | 180.00 | 01-JUN-00:10 | 392.68 | 01-JUN-19:10 | 237.03 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 148.97 | 06-JUN-15:10 | 124.62 | 10-JUN-05:00 |
July | 180.00 | 01-JUL-00:10 | 392.68 | 01-JUL-18:10 | 237.03 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 176.63 | 08-JUL-15:10 | 50.84 | 29-JUL-08:00 |
August | 180.00 | 01-AUG-00:10 | 392.68 | 01-AUG-19:10 | 237.03 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 158.83 | 02-AUG-16:00 | 34.40 | 25-AUG-06:00 |
September | 180.00 | 01-SEP-00:10 | 392.68 | 01-SEP-19:10 | 237.03 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 121.34 | 07-SEP-16:00 | 116.87 | 29-SEP-04:00 |
October | 180.00 | 01-OCT-00:10 | 392.68 | 01-OCT-18:10 | 237.03 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 102.47 | 10-OCT-16:00 | 243.14 | 26-OCT-07:00 |
November | 180.00 | 01-NOV-00:10 | 392.68 | 01-NOV-19:10 | 237.03 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.32 | 05-NOV-16:00 | 318.96 | 22-NOV-06:00 |
December | 180.00 | 01-DEC-00:10 | 392.68 | 01-DEC-20:10 | 237.03 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 13.13 | 12-DEC-14:00 | 355.46 | 18-DEC-08:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 180.00 | 392.68 | 237.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.40 | |||||
Maximum of Months | 180.00 | 392.68 | 237.03 | 0.00 | 0.00 | 0.00 | 0.00 | 176.63 | 467.24 |
Report: PeakSpaceGainsMonthly
For: CORRIDOR_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2263.36 | 02-JAN-00:10 | 1282.60 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.78 | 31-JAN-15:00 | 448.97 | 27-JAN-08:00 |
February | 2263.36 | 01-FEB-00:10 | 1282.60 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 55.98 | 28-FEB-14:30 | 563.11 | 12-FEB-07:00 |
March | 2263.36 | 01-MAR-00:10 | 1282.60 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 90.90 | 30-MAR-14:00 | 311.76 | 19-MAR-07:00 |
April | 2263.36 | 01-APR-00:10 | 1282.60 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 108.20 | 12-APR-14:00 | 328.99 | 06-APR-05:00 |
May | 2263.36 | 01-MAY-00:10 | 1282.60 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 127.37 | 30-MAY-14:00 | 200.76 | 11-MAY-06:00 |
June | 2263.36 | 01-JUN-00:10 | 1282.60 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 171.78 | 06-JUN-15:00 | 154.17 | 10-JUN-05:00 |
July | 2263.36 | 01-JUL-00:10 | 1282.60 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 199.82 | 08-JUL-16:00 | 65.84 | 28-JUL-22:53 |
August | 2263.36 | 01-AUG-00:10 | 1282.60 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 183.01 | 01-AUG-17:00 | 51.94 | 25-AUG-06:00 |
September | 2263.36 | 01-SEP-00:10 | 1282.60 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 135.75 | 07-SEP-16:00 | 140.79 | 29-SEP-04:00 |
October | 2263.36 | 01-OCT-23:10 | 1282.60 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 118.92 | 10-OCT-16:00 | 292.32 | 26-OCT-07:00 |
November | 2263.36 | 01-NOV-00:10 | 1282.60 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.92 | 05-NOV-16:00 | 383.99 | 22-NOV-06:20 |
December | 2263.36 | 01-DEC-00:10 | 1282.60 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.40 | 12-DEC-14:00 | 428.07 | 18-DEC-08:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
Minimum of Months | 2263.36 | 1282.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.78 | 51.94 | ||||
Maximum of Months | 2263.36 | 1282.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 199.82 | 563.11 |
Report: PeakSpaceGainsMonthly
For: ROOM_1_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 180.00 | 01-JAN-00:10 | 392.73 | 01-JAN-19:10 | 237.06 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 373.63 | 27-JAN-08:00 |
February | 180.00 | 01-FEB-00:10 | 392.73 | 01-FEB-20:10 | 237.06 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 36.71 | 26-FEB-16:10 | 468.20 | 12-FEB-07:00 |
March | 180.00 | 01-MAR-00:10 | 392.73 | 01-MAR-20:10 | 237.06 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 76.81 | 30-MAR-16:00 | 260.06 | 19-MAR-07:00 |
April | 180.00 | 01-APR-00:10 | 392.73 | 01-APR-18:10 | 237.06 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.63 | 17-APR-15:10 | 274.31 | 06-APR-05:00 |
May | 180.00 | 01-MAY-00:10 | 392.73 | 01-MAY-19:10 | 237.06 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 108.94 | 19-MAY-16:00 | 168.19 | 11-MAY-06:00 |
June | 180.00 | 01-JUN-00:10 | 392.73 | 01-JUN-19:10 | 237.06 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 148.34 | 06-JUN-15:10 | 125.39 | 10-JUN-05:00 |
July | 180.00 | 01-JUL-00:10 | 392.73 | 01-JUL-18:10 | 237.06 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 175.99 | 08-JUL-15:10 | 50.09 | 29-JUL-08:00 |
August | 180.00 | 01-AUG-00:10 | 392.73 | 01-AUG-19:10 | 237.06 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 158.19 | 02-AUG-16:00 | 35.12 | 25-AUG-06:00 |
September | 180.00 | 01-SEP-00:10 | 392.73 | 01-SEP-19:10 | 237.06 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 120.70 | 07-SEP-16:00 | 117.64 | 29-SEP-04:00 |
October | 180.00 | 01-OCT-00:10 | 392.73 | 01-OCT-18:10 | 237.06 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 101.81 | 10-OCT-16:00 | 243.97 | 26-OCT-07:00 |
November | 180.00 | 01-NOV-00:10 | 392.73 | 01-NOV-19:10 | 237.06 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.62 | 05-NOV-16:00 | 319.83 | 22-NOV-06:00 |
December | 180.00 | 01-DEC-00:10 | 392.73 | 01-DEC-20:10 | 237.06 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10.80 | 12-DEC-16:10 | 356.35 | 18-DEC-08:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 180.00 | 392.73 | 237.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.12 | |||||
Maximum of Months | 180.00 | 392.73 | 237.06 | 0.00 | 0.00 | 0.00 | 0.00 | 175.99 | 468.20 |
Report: PeakSpaceGainsMonthly
For: ROOM_2_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 180.00 | 01-JAN-00:10 | 392.68 | 01-JAN-19:10 | 237.03 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 373.61 | 27-JAN-08:00 |
February | 180.00 | 01-FEB-00:10 | 392.68 | 01-FEB-20:10 | 237.03 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 36.71 | 26-FEB-16:10 | 468.17 | 12-FEB-07:00 |
March | 180.00 | 01-MAR-00:10 | 392.68 | 01-MAR-20:10 | 237.03 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 76.80 | 30-MAR-16:00 | 260.03 | 19-MAR-07:00 |
April | 180.00 | 01-APR-00:10 | 392.68 | 01-APR-18:10 | 237.03 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.62 | 17-APR-15:10 | 274.29 | 06-APR-05:00 |
May | 180.00 | 01-MAY-00:10 | 392.68 | 01-MAY-19:10 | 237.03 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 108.93 | 19-MAY-16:00 | 168.18 | 11-MAY-06:00 |
June | 180.00 | 01-JUN-00:10 | 392.68 | 01-JUN-19:10 | 237.03 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 148.33 | 06-JUN-15:10 | 125.39 | 10-JUN-05:00 |
July | 180.00 | 01-JUL-00:10 | 392.68 | 01-JUL-18:10 | 237.03 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 175.98 | 08-JUL-15:10 | 49.99 | 29-JUL-08:00 |
August | 180.00 | 01-AUG-00:10 | 392.68 | 01-AUG-19:10 | 237.03 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 158.18 | 02-AUG-16:00 | 35.12 | 25-AUG-06:00 |
September | 180.00 | 01-SEP-00:10 | 392.68 | 01-SEP-19:10 | 237.03 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 120.69 | 07-SEP-16:00 | 117.63 | 29-SEP-04:00 |
October | 180.00 | 01-OCT-00:10 | 392.68 | 01-OCT-18:10 | 237.03 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 101.79 | 10-OCT-16:00 | 243.95 | 26-OCT-07:00 |
November | 180.00 | 01-NOV-00:10 | 392.68 | 01-NOV-19:10 | 237.03 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.62 | 05-NOV-16:00 | 319.81 | 22-NOV-06:30 |
December | 180.00 | 01-DEC-00:10 | 392.68 | 01-DEC-20:10 | 237.03 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10.80 | 12-DEC-16:10 | 356.32 | 18-DEC-08:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 180.00 | 392.68 | 237.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.12 | |||||
Maximum of Months | 180.00 | 392.68 | 237.03 | 0.00 | 0.00 | 0.00 | 0.00 | 175.98 | 468.17 |
Report: PeakSpaceGainsMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 180.00 | 01-JAN-00:10 | 246.88 | 01-JAN-19:10 | 232.26 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 191.16 | 27-JAN-08:00 |
February | 180.00 | 01-FEB-00:10 | 246.88 | 01-FEB-20:10 | 232.26 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.78 | 26-FEB-16:10 | 239.55 | 12-FEB-07:00 |
March | 180.00 | 01-MAR-00:10 | 246.88 | 01-MAR-20:10 | 232.26 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 39.30 | 30-MAR-16:00 | 133.05 | 19-MAR-07:00 |
April | 180.00 | 01-APR-00:10 | 246.88 | 01-APR-18:10 | 232.26 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.85 | 17-APR-15:10 | 140.35 | 06-APR-05:00 |
May | 180.00 | 01-MAY-00:10 | 246.88 | 01-MAY-19:10 | 232.26 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 55.74 | 19-MAY-16:00 | 86.05 | 11-MAY-06:00 |
June | 180.00 | 01-JUN-00:10 | 246.88 | 01-JUN-19:10 | 232.26 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 75.89 | 06-JUN-15:10 | 64.16 | 10-JUN-05:00 |
July | 180.00 | 01-JUL-00:10 | 246.88 | 01-JUL-18:10 | 232.26 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 90.05 | 08-JUL-15:10 | 27.20 | 29-JUL-08:00 |
August | 180.00 | 01-AUG-00:10 | 246.88 | 01-AUG-19:10 | 232.26 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 80.94 | 02-AUG-16:00 | 17.97 | 25-AUG-06:00 |
September | 180.00 | 01-SEP-00:10 | 246.88 | 01-SEP-19:10 | 232.26 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 61.75 | 07-SEP-16:00 | 60.19 | 29-SEP-04:00 |
October | 180.00 | 01-OCT-00:10 | 246.88 | 01-OCT-18:10 | 232.26 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 52.08 | 10-OCT-16:00 | 124.82 | 26-OCT-07:00 |
November | 180.00 | 01-NOV-00:10 | 246.88 | 01-NOV-19:10 | 232.26 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.25 | 05-NOV-16:00 | 163.63 | 22-NOV-06:00 |
December | 180.00 | 01-DEC-00:10 | 246.88 | 01-DEC-20:10 | 232.26 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 5.52 | 12-DEC-16:10 | 182.32 | 18-DEC-08:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 180.00 | 246.88 | 232.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.97 | |||||
Maximum of Months | 180.00 | 246.88 | 232.26 | 0.00 | 0.00 | 0.00 | 0.00 | 90.05 | 239.55 |
Report: PeakSpaceGainsMonthly
For: BANQUET_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 26988.77 | 02-JAN-00:10 | 3823.39 | 02-JAN-20:10 | 6747.90 | 01-JAN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 908.99 | 27-JAN-08:00 |
February | 26988.77 | 01-FEB-00:10 | 3823.39 | 01-FEB-20:10 | 6747.90 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 112.38 | 26-FEB-15:00 | 1139.61 | 12-FEB-07:00 |
March | 26988.77 | 01-MAR-00:10 | 3823.39 | 01-MAR-20:10 | 6747.90 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 189.35 | 30-MAR-14:00 | 639.91 | 19-MAR-07:00 |
April | 26988.77 | 01-APR-00:10 | 3823.39 | 03-APR-19:10 | 6747.90 | 01-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 221.77 | 12-APR-14:00 | 679.37 | 06-APR-05:00 |
May | 26988.77 | 01-MAY-00:10 | 3823.39 | 01-MAY-19:10 | 6747.90 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 262.24 | 19-MAY-14:00 | 429.99 | 11-MAY-06:00 |
June | 26988.77 | 01-JUN-00:10 | 3823.39 | 01-JUN-19:10 | 6747.90 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 356.44 | 06-JUN-15:00 | 334.15 | 10-JUN-05:00 |
July | 26988.77 | 01-JUL-00:10 | 3823.39 | 03-JUL-19:10 | 6747.90 | 01-JUL-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 427.08 | 08-JUL-16:00 | 172.42 | 28-JUL-22:53 |
August | 26988.77 | 01-AUG-00:10 | 3823.39 | 01-AUG-19:10 | 6747.90 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 375.52 | 01-AUG-17:00 | 119.79 | 25-AUG-06:00 |
September | 26988.77 | 01-SEP-00:10 | 3823.39 | 01-SEP-19:10 | 6747.90 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 286.78 | 07-SEP-15:00 | 310.92 | 29-SEP-04:00 |
October | 26988.77 | 01-OCT-23:10 | 3823.39 | 02-OCT-19:10 | 6747.90 | 01-OCT-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 243.28 | 10-OCT-16:00 | 605.00 | 26-OCT-05:00 |
November | 26988.77 | 01-NOV-00:10 | 3823.39 | 01-NOV-19:10 | 6747.90 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 95.00 | 05-NOV-16:00 | 781.17 | 22-NOV-06:00 |
December | 26988.77 | 01-DEC-00:10 | 3823.39 | 01-DEC-20:10 | 6747.90 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 49.66 | 12-DEC-14:20 | 866.89 | 18-DEC-08:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 26988.77 | 3823.39 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 119.79 | |||||
Maximum of Months | 26988.77 | 3823.39 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 427.08 | 1139.61 |
Report: PeakSpaceGainsMonthly
For: DINING_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 26988.77 | 02-JAN-00:10 | 3823.39 | 02-JAN-20:10 | 6747.90 | 01-JAN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 908.85 | 27-JAN-08:00 |
February | 26988.77 | 01-FEB-00:10 | 3823.39 | 01-FEB-20:10 | 6747.90 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 112.39 | 28-FEB-14:10 | 1139.53 | 12-FEB-07:00 |
March | 26988.77 | 01-MAR-00:10 | 3823.39 | 01-MAR-20:10 | 6747.90 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 186.18 | 30-MAR-14:00 | 641.76 | 19-MAR-07:00 |
April | 26988.77 | 01-APR-00:10 | 3823.39 | 03-APR-19:10 | 6747.90 | 01-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 218.72 | 12-APR-14:00 | 680.34 | 06-APR-05:00 |
May | 26988.77 | 01-MAY-00:10 | 3823.39 | 01-MAY-19:10 | 6747.90 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 258.94 | 19-MAY-14:00 | 431.80 | 11-MAY-06:00 |
June | 26988.77 | 01-JUN-00:10 | 3823.39 | 01-JUN-19:10 | 6747.90 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 353.52 | 06-JUN-15:00 | 335.35 | 10-JUN-05:00 |
July | 26988.77 | 01-JUL-00:10 | 3823.39 | 03-JUL-19:10 | 6747.90 | 01-JUL-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 424.98 | 08-JUL-16:00 | 175.33 | 28-JUL-22:53 |
August | 26988.77 | 01-AUG-00:10 | 3823.39 | 01-AUG-19:10 | 6747.90 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 373.10 | 01-AUG-17:00 | 121.51 | 25-AUG-06:00 |
September | 26988.77 | 01-SEP-00:10 | 3823.39 | 01-SEP-19:10 | 6747.90 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 284.18 | 07-SEP-15:00 | 311.97 | 29-SEP-04:00 |
October | 26988.77 | 01-OCT-23:10 | 3823.39 | 02-OCT-19:10 | 6747.90 | 01-OCT-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 240.99 | 10-OCT-16:00 | 605.85 | 26-OCT-05:00 |
November | 26988.77 | 01-NOV-00:10 | 3823.39 | 01-NOV-19:10 | 6747.90 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 95.12 | 05-NOV-16:00 | 781.92 | 22-NOV-06:00 |
December | 26988.77 | 01-DEC-00:10 | 3823.39 | 01-DEC-20:10 | 6747.90 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 49.56 | 12-DEC-14:40 | 866.71 | 18-DEC-08:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 26988.77 | 3823.39 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 121.51 | |||||
Maximum of Months | 26988.77 | 3823.39 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 424.98 | 1139.53 |
Report: PeakSpaceGainsMonthly
For: KITCHEN_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2401.70 | 02-JAN-00:10 | 1020.78 | 02-JAN-20:10 | 15112.11 | 01-JAN-07:10 | 22492.83 | 01-JAN-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 864.54 | 27-JAN-08:00 |
February | 2401.70 | 01-FEB-00:10 | 1020.78 | 01-FEB-20:10 | 15112.11 | 01-FEB-07:10 | 22492.83 | 01-FEB-16:10 | 0.00 | 0.00 | 0.00 | 35.67 | 28-FEB-15:00 | 1020.52 | 12-FEB-07:00 |
March | 2401.70 | 01-MAR-00:10 | 1020.78 | 01-MAR-20:10 | 15112.11 | 01-MAR-07:10 | 22492.83 | 01-MAR-16:10 | 0.00 | 0.00 | 0.00 | 100.07 | 30-MAR-14:00 | 599.86 | 19-MAR-07:00 |
April | 2401.70 | 01-APR-00:10 | 1020.78 | 03-APR-19:10 | 15112.11 | 01-APR-06:10 | 22492.83 | 01-APR-15:09 | 0.00 | 0.00 | 0.00 | 127.27 | 12-APR-14:00 | 596.60 | 06-APR-05:00 |
May | 2401.70 | 01-MAY-00:10 | 1020.78 | 01-MAY-19:10 | 15112.11 | 01-MAY-06:10 | 22492.83 | 01-MAY-15:09 | 0.00 | 0.00 | 0.00 | 165.72 | 19-MAY-14:00 | 393.31 | 11-MAY-06:00 |
June | 2401.70 | 01-JUN-00:10 | 1020.78 | 01-JUN-19:10 | 15112.11 | 01-JUN-06:10 | 22492.83 | 01-JUN-15:09 | 0.00 | 0.00 | 0.00 | 254.97 | 06-JUN-15:00 | 287.70 | 08-JUN-06:00 |
July | 2401.70 | 01-JUL-00:10 | 1020.78 | 03-JUL-19:10 | 15112.11 | 01-JUL-06:10 | 22492.83 | 01-JUL-15:09 | 0.00 | 0.00 | 0.00 | 313.20 | 08-JUL-15:00 | 168.11 | 28-JUL-22:40 |
August | 2401.70 | 01-AUG-00:10 | 1020.78 | 01-AUG-19:10 | 15112.11 | 01-AUG-06:10 | 22492.83 | 01-AUG-15:09 | 0.00 | 0.00 | 0.00 | 273.64 | 02-AUG-16:00 | 139.51 | 25-AUG-06:30 |
September | 2401.70 | 01-SEP-00:10 | 1020.78 | 01-SEP-19:10 | 15112.11 | 01-SEP-06:10 | 22492.83 | 01-SEP-15:09 | 0.00 | 0.00 | 0.00 | 191.47 | 07-SEP-15:40 | 281.56 | 29-SEP-06:30 |
October | 2401.70 | 01-OCT-23:10 | 1020.78 | 02-OCT-19:10 | 15112.11 | 01-OCT-06:10 | 22492.83 | 01-OCT-15:09 | 0.00 | 0.00 | 0.00 | 149.66 | 10-OCT-16:00 | 563.38 | 26-OCT-07:00 |
November | 2401.70 | 01-NOV-00:10 | 1020.78 | 01-NOV-19:10 | 15112.11 | 01-NOV-06:10 | 22492.83 | 01-NOV-15:09 | 0.00 | 0.00 | 0.00 | 26.95 | 19-NOV-15:00 | 738.98 | 21-NOV-08:00 |
December | 2401.70 | 01-DEC-00:10 | 1020.78 | 01-DEC-20:10 | 15112.11 | 01-DEC-07:10 | 22492.83 | 01-DEC-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 801.48 | 18-DEC-08:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 2401.70 | 1020.78 | 15112.11 | 22492.83 | 0.00 | 0.00 | 0.00 | 0.00 | 139.51 | ||||||
Maximum of Months | 2401.70 | 1020.78 | 15112.11 | 22492.83 | 0.00 | 0.00 | 0.00 | 313.20 | 1020.52 |
Report: PeakSpaceGainsMonthly
For: CORRIDOR_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2395.44 | 02-JAN-00:10 | 1357.44 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 794.20 | 14-JAN-06:00 |
February | 2395.44 | 01-FEB-00:10 | 1357.44 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 98.38 | 28-FEB-14:00 | 976.90 | 12-FEB-07:00 |
March | 2395.44 | 01-MAR-00:10 | 1357.44 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 159.68 | 30-MAR-16:00 | 553.26 | 19-MAR-07:00 |
April | 2395.44 | 01-APR-00:10 | 1357.44 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 183.40 | 12-APR-14:00 | 583.86 | 06-APR-05:00 |
May | 2395.44 | 01-MAY-00:10 | 1357.44 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 225.95 | 19-MAY-17:00 | 356.89 | 11-MAY-06:00 |
June | 2395.44 | 01-JUN-00:10 | 1357.44 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 306.38 | 06-JUN-15:00 | 265.34 | 10-JUN-05:00 |
July | 2395.44 | 01-JUL-00:10 | 1357.44 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 348.73 | 08-JUL-16:00 | 101.99 | 28-JUL-24:00 |
August | 2395.44 | 01-AUG-00:10 | 1357.44 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 319.98 | 01-AUG-17:00 | 72.32 | 25-AUG-06:00 |
September | 2395.44 | 01-SEP-00:10 | 1357.44 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 242.13 | 07-SEP-16:00 | 248.78 | 29-SEP-04:00 |
October | 2395.44 | 01-OCT-23:10 | 1357.44 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 209.41 | 10-OCT-16:00 | 518.95 | 26-OCT-07:00 |
November | 2395.44 | 01-NOV-00:10 | 1357.44 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 83.29 | 05-NOV-16:00 | 681.24 | 22-NOV-06:40 |
December | 2395.44 | 01-DEC-00:10 | 1357.44 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43.45 | 12-DEC-14:00 | 757.08 | 18-DEC-08:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||
Minimum of Months | 2395.44 | 1357.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.32 | ||||
Maximum of Months | 2395.44 | 1357.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 348.73 | 976.90 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: BASEMENT
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 18881.66 | 19-JAN-19:10 | 35783.66 | 48060.13 | 38325.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 18642.19 | 27-FEB-19:50 | 8945.92 | 12015.03 | 9581.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 18298.63 | 29-MAR-20:00 | 8945.92 | 13517.00 | 10113.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 16405.89 | 06-APR-20:50 | 10223.90 | 12015.03 | 9581.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 18831.87 | 15-MAY-19:40 | 17891.83 | 27034.00 | 20227.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 22645.47 | 07-JUN-18:03 | 62621.41 | 84105.23 | 67070.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 21713.39 | 06-JUL-19:10 | 17891.83 | 27034.00 | 20227.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 22932.45 | 10-AUG-18:08 | 53675.50 | 72090.20 | 57488.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 22879.00 | 07-SEP-18:10 | 53675.50 | 72090.20 | 57488.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 24758.38 | 11-OCT-17:10 | 44729.58 | 63078.92 | 52165.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 21418.43 | 02-NOV-18:10 | 44729.58 | 60075.16 | 47907.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 19996.91 | 13-DEC-19:10 | 26837.75 | 36045.10 | 28744.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 16405.89 | 8945.92 | 12015.03 | 9581.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 24758.38 | 62621.41 | 84105.23 | 67070.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: RETAIL_1_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2678.84 | 29-JAN-11:40 | 389.84 | 229.10 | 288.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 189.04 |
February | 2886.07 | 26-FEB-11:35 | 779.69 | 458.20 | 577.35 | 0.00 | 0.00 | 0.00 | 0.00 | 14.45 | 0.00 |
March | 2889.59 | 30-MAR-15:15 | 1299.48 | 381.83 | 505.18 | 0.00 | 0.00 | 0.00 | 0.00 | 115.55 | 0.00 |
April | 2871.97 | 12-APR-15:15 | 1299.48 | 381.83 | 505.18 | 0.00 | 0.00 | 0.00 | 0.00 | 127.85 | 0.00 |
May | 3059.62 | 15-MAY-18:56 | 4548.18 | 3054.65 | 3247.60 | 0.00 | 0.00 | 0.00 | 0.00 | 124.16 | 0.00 |
June | 3089.77 | 12-JUN-18:10 | 5457.82 | 3665.58 | 3897.11 | 0.00 | 0.00 | 0.00 | 0.00 | 209.04 | 0.00 |
July | 3308.58 | 08-JUL-17:25 | 1559.38 | 916.39 | 1010.36 | 0.00 | 0.00 | 0.00 | 0.00 | 255.34 | 0.00 |
August | 3342.76 | 19-AUG-10:35 | 779.69 | 381.83 | 505.18 | 0.00 | 0.00 | 0.00 | 0.00 | 211.61 | 0.00 |
September | 3290.42 | 25-SEP-10:35 | 519.79 | 381.83 | 505.18 | 0.00 | 0.00 | 0.00 | 0.00 | 124.61 | 0.00 |
October | 3480.15 | 11-OCT-17:10 | 4548.18 | 3207.38 | 3536.27 | 0.00 | 0.00 | 0.00 | 0.00 | 49.74 | 0.00 |
November | 2983.98 | 11-NOV-11:35 | 779.69 | 458.20 | 577.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 68.19 |
December | 2825.59 | 12-DEC-11:40 | 259.90 | 190.92 | 252.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32.51 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 2678.84 | 259.90 | 190.92 | 252.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 3480.15 | 5457.82 | 3665.58 | 3897.11 | 0.00 | 0.00 | 0.00 | 0.00 | 255.34 | 189.04 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: RETAIL_2_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1806.64 | 31-JAN-21:00 | 1053.36 | 795.89 | 793.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32.28 |
February | 1928.70 | 27-FEB-19:20 | 2106.72 | 1414.92 | 1504.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.08 |
March | 2225.01 | 11-MAR-19:01 | 6320.16 | 4333.19 | 4680.02 | 0.00 | 0.00 | 0.00 | 0.00 | 16.43 | 0.00 |
April | 2275.25 | 07-APR-18:10 | 6320.16 | 4244.75 | 4512.87 | 0.00 | 0.00 | 0.00 | 0.00 | 18.57 | 0.00 |
May | 2360.28 | 15-MAY-18:56 | 5266.80 | 3537.29 | 3760.73 | 0.00 | 0.00 | 0.00 | 0.00 | 45.49 | 0.00 |
June | 2428.97 | 07-JUN-18:03 | 7373.52 | 4952.21 | 5265.02 | 0.00 | 0.00 | 0.00 | 0.00 | 16.06 | 0.00 |
July | 2357.50 | 06-JUL-18:10 | 6320.16 | 4244.75 | 4512.87 | 0.00 | 0.00 | 0.00 | 0.00 | 83.91 | 0.00 |
August | 2367.81 | 02-AUG-18:10 | 6320.16 | 4244.75 | 4512.87 | 0.00 | 0.00 | 0.00 | 0.00 | 89.09 | 0.00 |
September | 2285.80 | 07-SEP-18:10 | 6320.16 | 4244.75 | 4512.87 | 0.00 | 0.00 | 0.00 | 0.00 | 65.85 | 0.00 |
October | 2424.66 | 11-OCT-17:10 | 5266.80 | 3714.16 | 4095.01 | 0.00 | 0.00 | 0.00 | 0.00 | 23.35 | 0.00 |
November | 1898.85 | 02-NOV-18:30 | 1053.36 | 707.46 | 752.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.94 |
December | 1856.72 | 12-DEC-21:00 | 1053.36 | 795.89 | 793.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.28 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1806.64 | 1053.36 | 707.46 | 752.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 2428.97 | 7373.52 | 4952.21 | 5265.02 | 0.00 | 0.00 | 0.00 | 0.00 | 89.09 | 32.28 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: MECH_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1685.86 | 31-JAN-21:00 | 222.77 | 1487.69 | 839.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 73.14 |
February | 1916.30 | 28-FEB-21:00 | 222.77 | 1487.69 | 839.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.97 |
March | 2135.87 | 30-MAR-18:40 | 222.77 | 1322.39 | 795.27 | 0.00 | 0.00 | 0.00 | 0.00 | 87.70 | 0.00 |
April | 2179.59 | 17-APR-19:10 | 668.30 | 4463.06 | 2518.34 | 0.00 | 0.00 | 0.00 | 0.00 | 65.90 | 0.00 |
May | 2404.27 | 15-MAY-18:56 | 1113.84 | 6611.94 | 3976.33 | 0.00 | 0.00 | 0.00 | 0.00 | 112.41 | 0.00 |
June | 2523.16 | 07-JUN-18:03 | 1559.38 | 9256.71 | 5566.86 | 0.00 | 0.00 | 0.00 | 0.00 | 39.17 | 0.00 |
July | 2493.71 | 08-JUL-18:10 | 1145.66 | 6942.53 | 4241.42 | 0.00 | 0.00 | 0.00 | 0.00 | 230.56 | 0.00 |
August | 2467.13 | 02-AUG-18:10 | 1336.61 | 7934.32 | 4771.59 | 0.00 | 0.00 | 0.00 | 0.00 | 212.23 | 0.00 |
September | 2370.21 | 07-SEP-18:10 | 1336.61 | 7934.32 | 4771.59 | 0.00 | 0.00 | 0.00 | 0.00 | 157.93 | 0.00 |
October | 2099.74 | 18-OCT-18:30 | 222.77 | 1322.39 | 795.27 | 0.00 | 0.00 | 0.00 | 0.00 | 58.47 | 0.00 |
November | 1900.50 | 03-NOV-20:00 | 222.77 | 1487.69 | 839.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 41.54 |
December | 1841.80 | 12-DEC-21:00 | 222.77 | 1487.69 | 839.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.67 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1685.86 | 222.77 | 1322.39 | 795.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 2523.16 | 1559.38 | 9256.71 | 5566.86 | 0.00 | 0.00 | 0.00 | 0.00 | 230.56 | 73.14 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: STORAGE_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 550.20 | 31-JAN-21:00 | 171.36 | 273.10 | 242.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.20 |
February | 735.49 | 28-FEB-21:50 | 195.84 | 242.76 | 229.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.79 |
March | 946.49 | 30-MAR-20:10 | 195.84 | 242.76 | 229.41 | 0.00 | 0.00 | 0.00 | 0.00 | 35.44 | 0.00 |
April | 912.81 | 18-APR-20:00 | 171.36 | 273.10 | 242.16 | 0.00 | 0.00 | 0.00 | 0.00 | 7.56 | 0.00 |
May | 1048.81 | 18-MAY-19:50 | 171.36 | 273.10 | 242.16 | 0.00 | 0.00 | 0.00 | 0.00 | 57.53 | 0.00 |
June | 1147.69 | 28-JUN-18:30 | 171.36 | 242.76 | 229.41 | 0.00 | 0.00 | 0.00 | 0.00 | 97.79 | 0.00 |
July | 1225.61 | 08-JUL-18:10 | 881.28 | 1274.46 | 1223.53 | 0.00 | 0.00 | 0.00 | 0.00 | 134.27 | 0.00 |
August | 1203.24 | 02-AUG-18:02 | 1028.16 | 1456.53 | 1376.47 | 0.00 | 0.00 | 0.00 | 0.00 | 123.55 | 0.00 |
September | 1099.54 | 07-SEP-19:10 | 342.72 | 546.20 | 484.31 | 0.00 | 0.00 | 0.00 | 0.00 | 75.07 | 0.00 |
October | 927.93 | 18-OCT-20:20 | 195.84 | 242.76 | 229.41 | 0.00 | 0.00 | 0.00 | 0.00 | 24.72 | 0.00 |
November | 730.08 | 03-NOV-21:00 | 195.84 | 242.76 | 229.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.76 |
December | 664.15 | 12-DEC-22:00 | 195.84 | 242.76 | 229.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.77 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 550.20 | 171.36 | 242.76 | 229.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 1225.61 | 1028.16 | 1456.53 | 1376.47 | 0.00 | 0.00 | 0.00 | 0.00 | 134.27 | 42.20 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: LAUNDRY_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 36002.87 | 31-JAN-21:00 | 705.60 | 337.37 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 0.00 | 178.50 |
February | 36467.45 | 28-FEB-21:00 | 705.60 | 337.37 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 0.00 | 86.99 |
March | 37013.05 | 30-MAR-20:00 | 705.60 | 337.37 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 17.03 | 0.00 |
April | 37804.61 | 07-APR-18:10 | 4233.60 | 1799.30 | 25992.76 | 225814.22 | 0.00 | 0.00 | 0.00 | 15.42 | 0.00 |
May | 38804.01 | 15-MAY-18:56 | 3528.00 | 1499.42 | 21660.63 | 188178.52 | 0.00 | 0.00 | 0.00 | 103.95 | 0.00 |
June | 37785.58 | 12-JUN-20:00 | 705.60 | 337.37 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 119.60 | 0.00 |
July | 38047.38 | 06-JUL-20:00 | 705.60 | 337.37 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 135.58 | 0.00 |
August | 38164.53 | 02-AUG-20:00 | 705.60 | 337.37 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 178.82 | 0.00 |
September | 37757.55 | 07-SEP-20:00 | 705.60 | 337.37 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 90.76 | 0.00 |
October | 36878.26 | 02-OCT-20:00 | 705.60 | 337.37 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 0.00 | 52.74 |
November | 36334.86 | 03-NOV-20:00 | 705.60 | 337.37 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 0.00 | 132.34 |
December | 36157.22 | 12-DEC-21:00 | 705.60 | 337.37 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 0.00 | 148.53 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||||
Minimum of Months | 36002.87 | 705.60 | 337.37 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 38804.01 | 4233.60 | 1799.30 | 25992.76 | 225814.22 | 0.00 | 0.00 | 0.00 | 178.82 | 178.50 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CAFE_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 11665.10 | 29-JAN-11:40 | 5122.80 | 725.74 | 406.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 420.48 |
February | 12367.70 | 26-FEB-11:35 | 10245.60 | 1451.48 | 812.86 | 0.00 | 0.00 | 0.00 | 0.00 | 34.59 | 0.00 |
March | 13055.11 | 11-MAR-19:01 | 71719.20 | 11853.78 | 5690.03 | 0.00 | 0.00 | 0.00 | 0.00 | 91.95 | 0.00 |
April | 13365.97 | 07-APR-18:10 | 71719.20 | 11611.87 | 5486.82 | 0.00 | 0.00 | 0.00 | 0.00 | 103.72 | 0.00 |
May | 13772.85 | 15-MAY-18:56 | 59766.00 | 9676.56 | 4572.35 | 0.00 | 0.00 | 0.00 | 0.00 | 260.18 | 0.00 |
June | 14062.97 | 07-JUN-18:03 | 83672.40 | 13547.18 | 6401.28 | 0.00 | 0.00 | 0.00 | 0.00 | 94.57 | 0.00 |
July | 13911.43 | 13-JUL-18:10 | 71719.20 | 11611.87 | 5486.82 | 0.00 | 0.00 | 0.00 | 0.00 | 503.19 | 0.00 |
August | 14033.27 | 02-AUG-18:10 | 71719.20 | 11611.87 | 5486.82 | 0.00 | 0.00 | 0.00 | 0.00 | 504.45 | 0.00 |
September | 13530.87 | 24-SEP-10:35 | 10245.60 | 1451.48 | 812.86 | 0.00 | 0.00 | 0.00 | 0.00 | 269.91 | 0.00 |
October | 14836.95 | 11-OCT-17:10 | 59766.00 | 10160.39 | 4978.78 | 0.00 | 0.00 | 0.00 | 0.00 | 115.15 | 0.00 |
November | 12736.35 | 11-NOV-11:35 | 10245.60 | 1451.48 | 812.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 146.59 |
December | 11939.23 | 10-DEC-11:40 | 5122.80 | 725.74 | 406.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 401.11 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 11665.10 | 5122.80 | 725.74 | 406.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 14836.95 | 83672.40 | 13547.18 | 6401.28 | 0.00 | 0.00 | 0.00 | 0.00 | 504.45 | 420.48 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: LOBBY_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 36461.88 | 31-JAN-21:00 | 35484.54 | 11849.32 | 10029.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 562.49 |
February | 38543.89 | 27-FEB-19:10 | 248391.78 | 73729.08 | 66509.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 163.12 |
March | 44019.66 | 11-MAR-19:01 | 212907.24 | 64512.95 | 59119.55 | 0.00 | 0.00 | 0.00 | 0.00 | 247.89 | 0.00 |
April | 44647.51 | 07-APR-18:10 | 212907.24 | 63196.36 | 57008.13 | 0.00 | 0.00 | 0.00 | 0.00 | 290.58 | 0.00 |
May | 46411.05 | 15-MAY-18:56 | 177422.70 | 52663.63 | 47506.78 | 0.00 | 0.00 | 0.00 | 0.00 | 728.86 | 0.00 |
June | 47153.24 | 07-JUN-18:03 | 248391.78 | 73729.08 | 66509.49 | 0.00 | 0.00 | 0.00 | 0.00 | 260.29 | 0.00 |
July | 46007.70 | 13-JUL-18:10 | 212907.24 | 63196.36 | 57008.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1442.05 | 0.00 |
August | 46117.59 | 02-AUG-18:10 | 212907.24 | 63196.36 | 57008.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1452.12 | 0.00 |
September | 44634.86 | 07-SEP-18:10 | 212907.24 | 63196.36 | 57008.13 | 0.00 | 0.00 | 0.00 | 0.00 | 1069.50 | 0.00 |
October | 47163.55 | 11-OCT-17:10 | 177422.70 | 55296.81 | 51729.60 | 0.00 | 0.00 | 0.00 | 0.00 | 377.29 | 0.00 |
November | 38454.56 | 02-NOV-18:10 | 177422.70 | 52663.63 | 47506.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 229.70 |
December | 37393.14 | 12-DEC-21:00 | 35484.54 | 11849.32 | 10029.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 430.34 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 36461.88 | 35484.54 | 11849.32 | 10029.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 47163.55 | 248391.78 | 73729.08 | 66509.49 | 0.00 | 0.00 | 0.00 | 0.00 | 1452.12 | 562.49 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_1_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3238.08 | 29-JAN-16:01 | 378.00 | 907.20 | 534.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.41 |
February | 3347.76 | 28-FEB-16:01 | 680.40 | 769.75 | 479.39 | 0.00 | 0.00 | 0.00 | 0.00 | 9.69 | 0.00 |
March | 3307.98 | 10-MAR-16:01 | 680.40 | 769.75 | 479.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.97 |
April | 3346.49 | 09-APR-18:01 | 819.00 | 2749.09 | 903.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.01 |
May | 3351.05 | 09-MAY-15:01 | 680.40 | 769.75 | 479.39 | 0.00 | 0.00 | 0.00 | 0.00 | 2.48 | 0.00 |
June | 3364.92 | 10-JUN-15:01 | 378.00 | 907.20 | 534.70 | 0.00 | 0.00 | 0.00 | 0.00 | 79.90 | 0.00 |
July | 3256.76 | 09-JUL-15:02 | 324.00 | 777.60 | 458.31 | 0.00 | 0.00 | 0.00 | 0.00 | 128.56 | 0.00 |
August | 3256.08 | 16-AUG-18:02 | 831.60 | 2097.16 | 774.39 | 0.00 | 0.00 | 0.00 | 0.00 | 108.44 | 0.00 |
September | 3257.62 | 08-SEP-15:02 | 583.20 | 659.78 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 97.03 | 0.00 |
October | 3354.35 | 12-OCT-15:01 | 680.40 | 769.75 | 479.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.06 |
November | 3343.01 | 11-NOV-16:01 | 378.00 | 907.20 | 534.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.98 |
December | 3244.44 | 10-DEC-16:02 | 324.00 | 777.60 | 458.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.32 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 3238.08 | 324.00 | 659.78 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 3364.92 | 831.60 | 2749.09 | 903.46 | 0.00 | 0.00 | 0.00 | 0.00 | 128.56 | 72.41 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_2_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1550.10 | 29-JAN-16:01 | 378.00 | 907.09 | 534.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 57.49 |
February | 3284.69 | 28-FEB-16:01 | 680.40 | 769.66 | 479.33 | 0.00 | 0.00 | 0.00 | 0.00 | 10.70 | 0.00 |
March | 3254.45 | 26-MAR-18:01 | 819.00 | 2748.77 | 903.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.91 |
April | 3300.46 | 09-APR-18:01 | 819.00 | 2748.77 | 903.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.58 |
May | 3308.43 | 09-MAY-15:01 | 680.40 | 769.66 | 479.33 | 0.00 | 0.00 | 0.00 | 0.00 | 2.76 | 0.00 |
June | 3329.91 | 10-JUN-15:01 | 378.00 | 907.09 | 534.64 | 0.00 | 0.00 | 0.00 | 0.00 | 79.90 | 0.00 |
July | 3229.21 | 21-JUL-15:02 | 583.20 | 659.70 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 122.05 | 0.00 |
August | 3211.30 | 19-AUG-15:02 | 324.00 | 777.51 | 458.26 | 0.00 | 0.00 | 0.00 | 0.00 | 120.37 | 0.00 |
September | 3169.33 | 08-SEP-18:02 | 831.60 | 2096.92 | 774.30 | 0.00 | 0.00 | 0.00 | 0.00 | 71.05 | 0.00 |
October | 3270.58 | 12-OCT-15:01 | 680.40 | 769.66 | 479.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.29 |
November | 3262.41 | 11-NOV-16:01 | 378.00 | 907.09 | 534.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.32 |
December | 2826.29 | 10-DEC-16:02 | 324.00 | 777.51 | 458.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32.24 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1550.10 | 324.00 | 659.70 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 3329.91 | 831.60 | 2748.77 | 903.35 | 0.00 | 0.00 | 0.00 | 0.00 | 122.05 | 57.49 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 405.24 | 29-JAN-13:30 | 0.00 | 81.45 | 74.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.00 |
February | 532.99 | 26-FEB-14:50 | 0.00 | 81.45 | 74.82 | 0.00 | 0.00 | 0.00 | 0.00 | 5.01 | 0.00 |
March | 510.15 | 30-MAR-13:40 | 0.00 | 69.11 | 67.08 | 0.00 | 0.00 | 0.00 | 0.00 | 13.22 | 0.00 |
April | 500.68 | 15-APR-14:00 | 0.00 | 81.45 | 74.82 | 0.00 | 0.00 | 0.00 | 0.00 | 14.44 | 0.00 |
May | 467.38 | 19-MAY-19:20 | 0.00 | 246.81 | 170.27 | 0.00 | 0.00 | 0.00 | 0.00 | 13.16 | 0.00 |
June | 524.25 | 24-JUN-19:10 | 0.00 | 246.81 | 170.27 | 0.00 | 0.00 | 0.00 | 0.00 | 22.17 | 0.00 |
July | 565.85 | 08-JUL-19:10 | 0.00 | 246.81 | 170.27 | 0.00 | 0.00 | 0.00 | 0.00 | 25.05 | 0.00 |
August | 581.04 | 19-AUG-14:00 | 0.00 | 81.45 | 74.82 | 0.00 | 0.00 | 0.00 | 0.00 | 33.58 | 0.00 |
September | 629.20 | 24-SEP-12:50 | 0.00 | 81.45 | 74.82 | 0.00 | 0.00 | 0.00 | 0.00 | 17.67 | 0.00 |
October | 661.18 | 10-OCT-13:30 | 0.00 | 69.11 | 67.08 | 0.00 | 0.00 | 0.00 | 0.00 | 17.79 | 0.00 |
November | 562.74 | 12-NOV-14:00 | 0.00 | 81.45 | 74.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.10 |
December | 540.18 | 10-DEC-14:30 | 0.00 | 81.45 | 74.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.01 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 405.24 | 0.00 | 69.11 | 67.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 661.18 | 0.00 | 246.81 | 170.27 | 0.00 | 0.00 | 0.00 | 0.00 | 33.58 | 31.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1036.60 | 01-JAN-09:02 | 270.00 | 691.27 | 799.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.52 |
February | 1167.65 | 28-FEB-19:02 | 831.60 | 1318.35 | 758.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.16 |
March | 1186.16 | 30-MAR-18:02 | 831.60 | 1318.35 | 758.70 | 0.00 | 0.00 | 0.00 | 0.00 | 10.68 | 0.00 |
April | 1180.75 | 18-APR-18:02 | 831.60 | 1318.35 | 758.70 | 0.00 | 0.00 | 0.00 | 0.00 | 4.50 | 0.00 |
May | 1201.21 | 09-MAY-15:01 | 680.40 | 483.89 | 469.67 | 0.00 | 0.00 | 0.00 | 0.00 | 1.95 | 0.00 |
June | 1254.50 | 10-JUN-15:01 | 378.00 | 570.30 | 523.86 | 0.00 | 0.00 | 0.00 | 0.00 | 21.69 | 0.00 |
July | 1191.84 | 16-JUL-18:02 | 702.00 | 1481.29 | 758.70 | 0.00 | 0.00 | 0.00 | 0.00 | 31.00 | 0.00 |
August | 1184.33 | 25-AUG-18:02 | 831.60 | 1318.35 | 758.70 | 0.00 | 0.00 | 0.00 | 0.00 | 22.55 | 0.00 |
September | 1188.34 | 15-SEP-18:02 | 831.60 | 1318.35 | 758.70 | 0.00 | 0.00 | 0.00 | 0.00 | 14.39 | 0.00 |
October | 1158.21 | 02-OCT-18:02 | 831.60 | 1318.35 | 758.70 | 0.00 | 0.00 | 0.00 | 0.00 | 5.23 | 0.00 |
November | 1118.52 | 06-NOV-16:01 | 680.40 | 483.89 | 469.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.37 |
December | 1022.22 | 12-DEC-16:02 | 583.20 | 414.76 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 3.01 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1022.22 | 270.00 | 414.76 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 1254.50 | 831.60 | 1481.29 | 799.99 | 0.00 | 0.00 | 0.00 | 0.00 | 31.00 | 33.52 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_5_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2795.54 | 29-JAN-16:01 | 378.00 | 907.20 | 534.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.56 |
February | 3035.45 | 28-FEB-16:01 | 680.40 | 769.75 | 479.39 | 0.00 | 0.00 | 0.00 | 0.00 | 10.04 | 0.00 |
March | 3006.97 | 26-MAR-15:01 | 378.00 | 907.20 | 534.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.04 |
April | 3034.36 | 09-APR-15:01 | 378.00 | 907.20 | 534.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.33 |
May | 3041.76 | 09-MAY-15:01 | 680.40 | 769.75 | 479.39 | 0.00 | 0.00 | 0.00 | 0.00 | 2.69 | 0.00 |
June | 3062.04 | 10-JUN-15:01 | 378.00 | 907.20 | 534.70 | 0.00 | 0.00 | 0.00 | 0.00 | 79.82 | 0.00 |
July | 2971.86 | 07-JUL-15:02 | 583.20 | 659.78 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 140.98 | 0.00 |
August | 2973.04 | 01-AUG-15:02 | 583.20 | 659.78 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 140.37 | 0.00 |
September | 2925.96 | 07-SEP-15:02 | 583.20 | 659.78 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 103.18 | 0.00 |
October | 3036.19 | 12-OCT-15:01 | 680.40 | 769.75 | 479.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.51 |
November | 3019.10 | 11-NOV-16:01 | 378.00 | 907.20 | 534.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.16 |
December | 2862.79 | 10-DEC-16:02 | 324.00 | 777.60 | 458.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.39 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 2795.54 | 324.00 | 659.78 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 3062.04 | 680.40 | 907.20 | 534.70 | 0.00 | 0.00 | 0.00 | 0.00 | 140.98 | 63.56 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_6_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 792.56 | 29-JAN-19:03 | 702.00 | 2356.09 | 774.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 100.23 |
February | 2921.88 | 28-FEB-16:01 | 680.40 | 769.66 | 479.33 | 0.00 | 0.00 | 0.00 | 0.00 | 14.78 | 0.00 |
March | 2842.64 | 27-MAR-15:02 | 583.20 | 659.70 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.48 |
April | 2970.48 | 10-APR-15:02 | 583.20 | 659.70 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 37.85 | 0.00 |
May | 3009.39 | 09-MAY-15:01 | 680.40 | 769.66 | 479.33 | 0.00 | 0.00 | 0.00 | 0.00 | 2.97 | 0.00 |
June | 3035.66 | 10-JUN-15:01 | 378.00 | 907.09 | 534.64 | 0.00 | 0.00 | 0.00 | 0.00 | 79.85 | 0.00 |
July | 2929.65 | 08-JUL-15:02 | 324.00 | 777.51 | 458.26 | 0.00 | 0.00 | 0.00 | 0.00 | 158.33 | 0.00 |
August | 2906.53 | 19-AUG-15:02 | 324.00 | 777.51 | 458.26 | 0.00 | 0.00 | 0.00 | 0.00 | 120.03 | 0.00 |
September | 2830.94 | 25-SEP-15:02 | 583.20 | 659.70 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 78.88 | 0.00 |
October | 2856.91 | 12-OCT-15:01 | 680.40 | 769.66 | 479.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.10 |
November | 2668.42 | 06-NOV-16:01 | 680.40 | 769.66 | 479.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.89 |
December | 1556.96 | 12-DEC-16:02 | 583.20 | 659.70 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 11.14 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 792.56 | 324.00 | 659.70 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 3035.66 | 702.00 | 2356.09 | 774.30 | 0.00 | 0.00 | 0.00 | 0.00 | 158.33 | 100.23 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORRIDOR_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1933.19 | 31-JAN-21:45 | 4023.74 | 2280.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85.83 |
February | 2303.48 | 27-FEB-19:10 | 12322.72 | 7980.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.35 |
March | 2643.53 | 11-MAR-19:01 | 10562.33 | 6983.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.90 | 0.00 |
April | 2761.55 | 19-APR-18:02 | 10562.33 | 6840.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.95 | 0.00 |
May | 2769.11 | 20-MAY-10:35 | 1508.90 | 712.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 82.64 | 0.00 |
June | 2998.77 | 07-JUN-18:03 | 12322.72 | 7980.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.36 | 0.00 |
July | 3112.96 | 08-JUL-10:35 | 1508.90 | 712.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 155.61 | 0.00 |
August | 3124.99 | 19-AUG-10:35 | 1508.90 | 712.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 138.03 | 0.00 |
September | 2932.82 | 09-SEP-10:35 | 1508.90 | 712.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 115.72 | 0.00 |
October | 2985.87 | 11-OCT-17:10 | 8801.94 | 5985.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.18 | 0.00 |
November | 2173.47 | 02-NOV-18:50 | 1760.39 | 1140.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.21 |
December | 2073.47 | 12-DEC-21:00 | 1760.39 | 1282.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 41.14 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 1933.19 | 1508.90 | 712.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 3124.99 | 12322.72 | 7980.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 155.61 | 85.83 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_1_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3428.34 | 29-JAN-16:01 | 378.00 | 907.20 | 534.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.14 |
February | 3564.95 | 28-FEB-16:01 | 680.40 | 769.75 | 479.39 | 0.00 | 0.00 | 0.00 | 0.00 | 9.23 | 0.00 |
March | 3526.39 | 10-MAR-16:01 | 680.40 | 769.75 | 479.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.56 |
April | 3573.84 | 09-APR-15:01 | 378.00 | 907.20 | 534.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.49 |
May | 3577.41 | 09-MAY-15:01 | 680.40 | 769.75 | 479.39 | 0.00 | 0.00 | 0.00 | 0.00 | 1.73 | 0.00 |
June | 3597.06 | 10-JUN-15:01 | 378.00 | 907.20 | 534.70 | 0.00 | 0.00 | 0.00 | 0.00 | 79.02 | 0.00 |
July | 3469.59 | 05-JUL-18:02 | 831.60 | 2097.16 | 774.39 | 0.00 | 0.00 | 0.00 | 0.00 | 101.50 | 0.00 |
August | 3478.77 | 17-AUG-18:02 | 831.60 | 2097.16 | 774.39 | 0.00 | 0.00 | 0.00 | 0.00 | 107.08 | 0.00 |
September | 3414.61 | 08-SEP-18:02 | 831.60 | 2097.16 | 774.39 | 0.00 | 0.00 | 0.00 | 0.00 | 69.84 | 0.00 |
October | 3571.76 | 12-OCT-15:01 | 680.40 | 769.75 | 479.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.51 |
November | 3559.21 | 11-NOV-16:01 | 378.00 | 907.20 | 534.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.43 |
December | 3443.74 | 10-DEC-16:02 | 324.00 | 777.60 | 458.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.38 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 3414.61 | 324.00 | 769.75 | 458.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 3597.06 | 831.60 | 2097.16 | 774.39 | 0.00 | 0.00 | 0.00 | 0.00 | 107.08 | 72.14 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_2_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 776.93 | 28-JAN-16:03 | 324.00 | 777.51 | 458.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 112.86 |
February | 3491.65 | 28-FEB-16:01 | 680.40 | 769.66 | 479.33 | 0.00 | 0.00 | 0.00 | 0.00 | 10.31 | 0.00 |
March | 3456.92 | 26-MAR-18:01 | 819.00 | 2748.77 | 903.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32.21 |
April | 3518.46 | 09-APR-18:01 | 819.00 | 2748.77 | 903.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.32 |
May | 3528.00 | 09-MAY-15:01 | 680.40 | 769.66 | 479.33 | 0.00 | 0.00 | 0.00 | 0.00 | 2.01 | 0.00 |
June | 3555.92 | 10-JUN-15:01 | 378.00 | 907.09 | 534.64 | 0.00 | 0.00 | 0.00 | 0.00 | 79.01 | 0.00 |
July | 3429.31 | 05-JUL-18:02 | 831.60 | 2096.92 | 774.30 | 0.00 | 0.00 | 0.00 | 0.00 | 101.28 | 0.00 |
August | 3425.59 | 06-AUG-15:02 | 324.00 | 777.51 | 458.26 | 0.00 | 0.00 | 0.00 | 0.00 | 105.94 | 0.00 |
September | 3414.65 | 08-SEP-15:02 | 583.20 | 659.70 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 96.67 | 0.00 |
October | 3474.16 | 12-OCT-15:01 | 680.40 | 769.66 | 479.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.60 |
November | 3460.45 | 11-NOV-16:01 | 378.00 | 907.09 | 534.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.47 |
December | 2817.96 | 11-DEC-16:02 | 583.20 | 659.70 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.86 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 776.93 | 324.00 | 659.70 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 3555.92 | 831.60 | 2748.77 | 903.35 | 0.00 | 0.00 | 0.00 | 0.00 | 105.94 | 112.86 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1847.32 | 29-JAN-16:01 | 378.00 | 570.30 | 523.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38.99 |
February | 1897.19 | 21-FEB-16:01 | 680.40 | 483.89 | 469.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.18 |
March | 1895.14 | 13-MAR-15:02 | 583.20 | 414.76 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 7.22 | 0.00 |
April | 1891.69 | 09-APR-15:01 | 378.00 | 570.30 | 523.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.62 |
May | 1867.67 | 10-MAY-15:01 | 680.40 | 483.89 | 469.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.19 |
June | 1864.02 | 10-JUN-18:02 | 702.00 | 1481.29 | 758.70 | 0.00 | 0.00 | 0.00 | 0.00 | 35.78 | 0.00 |
July | 1834.07 | 15-JUL-15:02 | 324.00 | 488.83 | 449.03 | 0.00 | 0.00 | 0.00 | 0.00 | 59.45 | 0.00 |
August | 1822.27 | 06-AUG-15:02 | 324.00 | 488.83 | 449.03 | 0.00 | 0.00 | 0.00 | 0.00 | 53.52 | 0.00 |
September | 1818.58 | 25-SEP-15:02 | 583.20 | 414.76 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 38.19 | 0.00 |
October | 1896.06 | 13-OCT-15:02 | 583.20 | 414.76 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.16 |
November | 1902.17 | 11-NOV-16:01 | 378.00 | 570.30 | 523.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.22 |
December | 1865.55 | 10-DEC-16:02 | 324.00 | 488.83 | 449.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.49 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1818.58 | 324.00 | 414.76 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 1902.17 | 702.00 | 1481.29 | 758.70 | 0.00 | 0.00 | 0.00 | 0.00 | 59.45 | 38.99 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: BANQUET_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 19602.47 | 19-JAN-23:00 | 26988.77 | 2548.93 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 132.00 |
February | 19830.90 | 28-FEB-23:00 | 26988.77 | 2548.93 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 167.01 |
March | 22417.35 | 11-MAR-19:01 | 125947.58 | 20816.25 | 47235.32 | 0.00 | 0.00 | 0.00 | 0.00 | 39.34 | 0.00 |
April | 23015.69 | 07-APR-18:10 | 125947.58 | 20391.43 | 40487.42 | 0.00 | 0.00 | 0.00 | 0.00 | 45.58 | 0.00 |
May | 24194.37 | 15-MAY-18:56 | 104956.32 | 16992.86 | 33739.51 | 0.00 | 0.00 | 0.00 | 0.00 | 140.85 | 0.00 |
June | 24138.41 | 07-JUN-18:03 | 146938.85 | 23790.00 | 47235.32 | 0.00 | 0.00 | 0.00 | 0.00 | 39.85 | 0.00 |
July | 23913.69 | 13-JUL-18:10 | 125947.58 | 20391.43 | 40487.42 | 0.00 | 0.00 | 0.00 | 0.00 | 302.18 | 0.00 |
August | 23846.06 | 02-AUG-18:10 | 125947.58 | 20391.43 | 40487.42 | 0.00 | 0.00 | 0.00 | 0.00 | 305.68 | 0.00 |
September | 22738.52 | 07-SEP-18:10 | 125947.58 | 20391.43 | 40487.42 | 0.00 | 0.00 | 0.00 | 0.00 | 223.82 | 0.00 |
October | 23314.20 | 11-OCT-17:10 | 104956.32 | 17842.50 | 47235.32 | 0.00 | 0.00 | 0.00 | 0.00 | 74.71 | 0.00 |
November | 19935.41 | 03-NOV-22:00 | 26988.77 | 2548.93 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 152.62 |
December | 19771.22 | 12-DEC-23:00 | 26988.77 | 2548.93 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 135.97 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 19602.47 | 26988.77 | 2548.93 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 24194.37 | 146938.85 | 23790.00 | 47235.32 | 0.00 | 0.00 | 0.00 | 0.00 | 305.68 | 167.01 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: DINING_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 20847.12 | 19-JAN-23:00 | 26988.77 | 2548.93 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 134.88 |
February | 21085.71 | 28-FEB-23:00 | 26988.77 | 2548.93 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 169.93 |
March | 23856.52 | 11-MAR-19:01 | 125947.58 | 20816.25 | 47235.32 | 0.00 | 0.00 | 0.00 | 0.00 | 35.92 | 0.00 |
April | 24466.92 | 07-APR-18:10 | 125947.58 | 20391.43 | 40487.42 | 0.00 | 0.00 | 0.00 | 0.00 | 42.30 | 0.00 |
May | 25669.77 | 15-MAY-18:56 | 104956.32 | 16992.86 | 33739.51 | 0.00 | 0.00 | 0.00 | 0.00 | 137.97 | 0.00 |
June | 25698.85 | 07-JUN-18:03 | 146938.85 | 23790.00 | 47235.32 | 0.00 | 0.00 | 0.00 | 0.00 | 36.07 | 0.00 |
July | 25281.61 | 13-JUL-18:10 | 125947.58 | 20391.43 | 40487.42 | 0.00 | 0.00 | 0.00 | 0.00 | 300.27 | 0.00 |
August | 25202.07 | 02-AUG-18:10 | 125947.58 | 20391.43 | 40487.42 | 0.00 | 0.00 | 0.00 | 0.00 | 303.85 | 0.00 |
September | 24086.26 | 07-SEP-18:10 | 125947.58 | 20391.43 | 40487.42 | 0.00 | 0.00 | 0.00 | 0.00 | 221.53 | 0.00 |
October | 24750.80 | 11-OCT-17:10 | 104956.32 | 17842.50 | 47235.32 | 0.00 | 0.00 | 0.00 | 0.00 | 71.76 | 0.00 |
November | 21199.31 | 03-NOV-22:00 | 26988.77 | 2548.93 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 155.57 |
December | 21008.20 | 12-DEC-23:00 | 26988.77 | 2548.93 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 138.73 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 20847.12 | 26988.77 | 2548.93 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 25698.85 | 146938.85 | 23790.00 | 47235.32 | 0.00 | 0.00 | 0.00 | 0.00 | 303.85 | 169.93 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: KITCHEN_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 26130.53 | 31-JAN-11:50 | 533.71 | 283.55 | 15112.11 | 18744.03 | 0.00 | 0.00 | 0.00 | 0.00 | 193.99 |
February | 27617.50 | 26-FEB-11:50 | 800.57 | 340.26 | 15112.11 | 18744.03 | 0.00 | 0.00 | 0.00 | 0.00 | 44.34 |
March | 30232.80 | 11-MAR-19:01 | 11207.95 | 5557.57 | 105784.74 | 104966.55 | 0.00 | 0.00 | 0.00 | 0.00 | 32.74 |
April | 30023.66 | 19-APR-18:02 | 11207.95 | 5444.15 | 90672.63 | 89971.33 | 0.00 | 0.00 | 0.00 | 12.00 | 0.00 |
May | 31049.17 | 13-MAY-10:50 | 2401.70 | 850.65 | 45336.32 | 56232.08 | 0.00 | 0.00 | 0.00 | 0.00 | 30.79 |
June | 31815.65 | 07-JUN-18:03 | 13075.94 | 6351.51 | 105784.74 | 104966.55 | 0.00 | 0.00 | 0.00 | 0.00 | 30.46 |
July | 31122.70 | 08-JUL-10:50 | 800.57 | 283.55 | 15112.11 | 18744.03 | 0.00 | 0.00 | 0.00 | 237.59 | 0.00 |
August | 30830.55 | 19-AUG-10:50 | 800.57 | 283.55 | 15112.11 | 18744.03 | 0.00 | 0.00 | 0.00 | 202.28 | 0.00 |
September | 30245.12 | 09-SEP-10:50 | 800.57 | 283.55 | 15112.11 | 18744.03 | 0.00 | 0.00 | 0.00 | 157.84 | 0.00 |
October | 31547.43 | 11-OCT-17:10 | 9339.96 | 4763.63 | 105784.74 | 157449.82 | 0.00 | 0.00 | 0.00 | 0.00 | 4.54 |
November | 27196.46 | 11-NOV-11:40 | 1601.14 | 680.52 | 30224.21 | 37488.05 | 0.00 | 0.00 | 0.00 | 0.00 | 147.21 |
December | 26763.80 | 12-DEC-11:50 | 533.71 | 283.55 | 15112.11 | 18744.03 | 0.00 | 0.00 | 0.00 | 0.00 | 99.98 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||||
Minimum of Months | 26130.53 | 533.71 | 283.55 | 15112.11 | 18744.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 31815.65 | 13075.94 | 6351.51 | 105784.74 | 157449.82 | 0.00 | 0.00 | 0.00 | 237.59 | 193.99 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORRIDOR_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2991.11 | 31-JAN-21:10 | 2129.28 | 1206.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 112.44 |
February | 5056.75 | 27-FEB-16:30 | 1330.80 | 377.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.12 | 0.00 |
March | 6044.28 | 30-MAR-17:12 | 5323.20 | 3619.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 132.34 | 0.00 |
April | 6506.09 | 19-APR-18:02 | 11178.72 | 7239.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 88.97 | 0.00 |
May | 6606.60 | 15-MAY-18:56 | 9315.60 | 6033.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 148.73 | 0.00 |
June | 7033.96 | 13-JUN-17:12 | 5323.20 | 3619.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 266.50 | 0.00 |
July | 7635.77 | 08-JUL-17:13 | 4790.88 | 2714.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 296.92 | 0.00 |
August | 7421.39 | 19-AUG-10:35 | 1596.96 | 754.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 251.20 | 0.00 |
September | 6808.04 | 09-SEP-10:35 | 1596.96 | 754.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 215.85 | 0.00 |
October | 7060.73 | 11-OCT-17:10 | 9315.60 | 6334.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 69.60 | 0.00 |
November | 4972.03 | 05-NOV-15:30 | 798.48 | 301.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 76.72 | 0.00 |
December | 4057.28 | 12-DEC-14:00 | 532.32 | 377.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43.45 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 2991.11 | 532.32 | 301.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 7635.77 | 11178.72 | 7239.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 296.92 | 112.44 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | NATURALGAS:FACILITY [J] | NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | |
January | 0.559121E+12 | 401780.54 | 19-JAN-20:10 | 0.674083E+12 | 592977.58 | 07-JAN-17:10 |
February | 0.524698E+12 | 411315.25 | 28-FEB-20:49 | 0.569622E+12 | 537935.88 | 11-FEB-23:00 |
March | 0.633304E+12 | 480899.41 | 30-MAR-19:10 | 0.539180E+12 | 413852.32 | 22-MAR-16:00 |
April | 0.691997E+12 | 480955.87 | 04-APR-19:00 | 0.498000E+12 | 395904.17 | 07-APR-17:00 |
May | 0.843273E+12 | 525494.58 | 30-MAY-19:40 | 0.479994E+12 | 412894.53 | 14-MAY-17:40 |
June | 0.957500E+12 | 571118.19 | 28-JUN-18:10 | 0.432831E+12 | 366101.00 | 04-JUN-16:10 |
July | 0.107643E+13 | 598797.30 | 06-JUL-18:10 | 0.432421E+12 | 354074.06 | 30-JUL-16:00 |
August | 0.109809E+13 | 598806.25 | 02-AUG-19:40 | 0.422761E+12 | 349060.50 | 13-AUG-16:00 |
September | 0.893164E+12 | 564622.59 | 07-SEP-19:10 | 0.421099E+12 | 361517.16 | 29-SEP-17:30 |
October | 0.711335E+12 | 534298.57 | 18-OCT-19:00 | 0.476510E+12 | 396866.42 | 30-OCT-16:30 |
November | 0.599807E+12 | 463679.64 | 27-NOV-20:10 | 0.507090E+12 | 416897.71 | 30-NOV-17:49 |
December | 0.568716E+12 | 397877.56 | 12-DEC-20:10 | 0.589959E+12 | 441460.36 | 25-DEC-17:00 |
Annual Sum or Average | 0.915743E+13 | 0.604355E+13 | ||||
Minimum of Months | 0.524698E+12 | 397877.56 | 0.421099E+12 | 349060.50 | ||
Maximum of Months | 0.109809E+13 | 598806.25 | 0.674083E+12 | 592977.58 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [J] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [J] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [J] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
January | 0.997859E+11 | 0.259769E+11 | 0.148746E+12 | 0.577258E+11 | 0.150931E+12 | 0.733501E+10 | 0.00 | 0.116685E+11 | 0.00 | 0.00 | 0.430316E+11 | 0.770838E+10 | 0.00 |
February | 0.901073E+11 | 0.221715E+11 | 0.134341E+12 | 0.521396E+11 | 0.135299E+12 | 0.113176E+11 | 0.00 | 0.346587E+11 | 0.00 | 0.00 | 0.320590E+11 | 0.696533E+10 | 0.00 |
March | 0.995228E+11 | 0.226722E+11 | 0.148757E+12 | 0.577286E+11 | 0.148828E+12 | 0.216110E+11 | 0.00 | 0.925008E+11 | 0.00 | 0.00 | 0.276730E+11 | 0.770626E+10 | 0.00 |
April | 0.965474E+11 | 0.200685E+11 | 0.143913E+12 | 0.558635E+11 | 0.146777E+12 | 0.266345E+11 | 0.00 | 0.164768E+12 | 0.00 | 0.00 | 0.238094E+11 | 0.746777E+10 | 0.00 |
May | 0.996636E+11 | 0.191072E+11 | 0.148757E+12 | 0.577273E+11 | 0.155184E+12 | 0.324665E+11 | 0.00 | 0.287495E+12 | 0.00 | 0.00 | 0.287465E+11 | 0.770683E+10 | 0.00 |
June | 0.963626E+11 | 0.177753E+11 | 0.143963E+12 | 0.558662E+11 | 0.155722E+12 | 0.345423E+11 | 0.00 | 0.401550E+12 | 0.00 | 0.00 | 0.380319E+11 | 0.745917E+10 | 0.00 |
July | 0.998551E+11 | 0.186365E+11 | 0.148708E+12 | 0.577246E+11 | 0.162817E+12 | 0.373548E+11 | 0.00 | 0.491938E+12 | 0.00 | 0.00 | 0.452588E+11 | 0.771488E+10 | 0.00 |
August | 0.995413E+11 | 0.199984E+11 | 0.148768E+12 | 0.577287E+11 | 0.163686E+12 | 0.376247E+11 | 0.00 | 0.510340E+12 | 0.00 | 0.00 | 0.462472E+11 | 0.770673E+10 | 0.00 |
September | 0.965794E+11 | 0.211300E+11 | 0.143924E+12 | 0.558636E+11 | 0.151885E+12 | 0.331058E+11 | 0.00 | 0.342861E+12 | 0.00 | 0.00 | 0.341164E+11 | 0.746870E+10 | 0.00 |
October | 0.997606E+11 | 0.237738E+11 | 0.148735E+12 | 0.577257E+11 | 0.150942E+12 | 0.260638E+11 | 0.00 | 0.160395E+12 | 0.00 | 0.00 | 0.298663E+11 | 0.770610E+10 | 0.00 |
November | 0.965244E+11 | 0.247051E+11 | 0.143978E+12 | 0.558644E+11 | 0.143580E+12 | 0.183357E+11 | 0.00 | 0.734032E+11 | 0.00 | 0.00 | 0.298805E+11 | 0.745210E+10 | 0.00 |
December | 0.998619E+11 | 0.264376E+11 | 0.148708E+12 | 0.577246E+11 | 0.148331E+12 | 0.109228E+11 | 0.00 | 0.217188E+11 | 0.00 | 0.00 | 0.410478E+11 | 0.771622E+10 | 0.00 |
Annual Sum or Average | 0.117411E+13 | 0.262453E+12 | 0.175130E+13 | 0.679683E+12 | 0.181398E+13 | 0.297314E+12 | 0.00 | 0.259330E+13 | 0.00 | 0.00 | 0.419769E+12 | 0.907785E+11 | 0.00 |
Minimum of Months | 0.901073E+11 | 0.177753E+11 | 0.134341E+12 | 0.521396E+11 | 0.135299E+12 | 0.733501E+10 | 0.00 | 0.116685E+11 | 0.00 | 0.00 | 0.238094E+11 | 0.696533E+10 | 0.00 |
Maximum of Months | 0.998619E+11 | 0.264376E+11 | 0.148768E+12 | 0.577287E+11 | 0.163686E+12 | 0.376247E+11 | 0.00 | 0.510340E+12 | 0.00 | 0.00 | 0.462472E+11 | 0.771622E+10 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [J] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [J] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [J] | COGENERATION:NATURALGAS [] | HUMIDIFIER:NATURALGAS [] | |
January | 0.151918E+12 | 0.00 | 0.243967E+12 | 0.00 | 0.278198E+12 | 0.00 | 0.00 |
February | 0.137204E+12 | 0.00 | 0.180790E+12 | 0.00 | 0.251628E+12 | 0.00 | 0.00 |
March | 0.152024E+12 | 0.00 | 0.114475E+12 | 0.00 | 0.272681E+12 | 0.00 | 0.00 |
April | 0.146956E+12 | 0.00 | 0.979048E+11 | 0.00 | 0.253140E+12 | 0.00 | 0.00 |
May | 0.151978E+12 | 0.00 | 0.795422E+11 | 0.00 | 0.248473E+12 | 0.00 | 0.00 |
June | 0.147114E+12 | 0.00 | 0.565147E+11 | 0.00 | 0.229203E+12 | 0.00 | 0.00 |
July | 0.151820E+12 | 0.00 | 0.508593E+11 | 0.00 | 0.229741E+12 | 0.00 | 0.00 |
August | 0.152039E+12 | 0.00 | 0.414317E+11 | 0.00 | 0.229291E+12 | 0.00 | 0.00 |
September | 0.146971E+12 | 0.00 | 0.462843E+11 | 0.00 | 0.227844E+12 | 0.00 | 0.00 |
October | 0.151903E+12 | 0.00 | 0.780690E+11 | 0.00 | 0.246538E+12 | 0.00 | 0.00 |
November | 0.147091E+12 | 0.00 | 0.108694E+12 | 0.00 | 0.251305E+12 | 0.00 | 0.00 |
December | 0.151820E+12 | 0.00 | 0.166909E+12 | 0.00 | 0.271230E+12 | 0.00 | 0.00 |
Annual Sum or Average | 0.178884E+13 | 0.00 | 0.126544E+13 | 0.00 | 0.298927E+13 | 0.00 | 0.00 |
Minimum of Months | 0.137204E+12 | 0.00 | 0.414317E+11 | 0.00 | 0.227844E+12 | 0.00 | 0.00 |
Maximum of Months | 0.152039E+12 | 0.00 | 0.243967E+12 | 0.00 | 0.278198E+12 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum} [W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | EXTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | FANS:ELECTRICITY {Maximum} [W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY {Maximum} [W] | PUMPS:ELECTRICITY {TIMESTAMP} | HEATING:ELECTRICITY {Maximum} [W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 93091.76 | 02-JAN-20:10 | 16690.39 | 01-JAN-00:10 | 89674.66 | 02-JAN-07:10 | 40537.60 | 02-JAN-07:19 | 75345.27 | 07-JAN-16:10 | 12639.07 | 31-JAN-14:50 | 0.00 | 01-JAN-00:10 |
February | 93091.76 | 01-FEB-20:10 | 16690.39 | 01-FEB-00:10 | 89674.66 | 01-FEB-07:10 | 40537.60 | 01-FEB-07:19 | 69076.22 | 03-FEB-09:09 | 12981.99 | 28-FEB-16:30 | 0.00 | 01-FEB-00:10 |
March | 93091.76 | 01-MAR-20:10 | 16690.39 | 01-MAR-00:10 | 89674.66 | 01-MAR-07:10 | 40537.60 | 01-MAR-07:19 | 68975.03 | 30-MAR-18:10 | 14244.75 | 13-MAR-16:19 | 0.00 | 01-MAR-00:10 |
April | 93091.76 | 03-APR-19:10 | 16690.39 | 01-APR-00:10 | 89674.66 | 03-APR-06:10 | 40537.60 | 03-APR-06:19 | 71504.56 | 15-APR-15:09 | 14553.88 | 15-APR-10:50 | 0.00 | 01-APR-00:10 |
May | 93091.76 | 01-MAY-19:10 | 16690.39 | 01-MAY-00:10 | 89674.66 | 01-MAY-06:10 | 40537.60 | 01-MAY-06:19 | 71817.15 | 30-MAY-15:20 | 14634.99 | 30-MAY-10:39 | 0.00 | 01-MAY-00:10 |
June | 93091.76 | 01-JUN-19:10 | 16690.39 | 01-JUN-00:10 | 89674.66 | 01-JUN-06:10 | 40537.60 | 01-JUN-06:19 | 74686.55 | 24-JUN-18:19 | 15023.60 | 28-JUN-10:39 | 0.00 | 01-JUN-00:10 |
July | 93091.76 | 03-JUL-19:10 | 16690.39 | 01-JUL-00:10 | 89674.66 | 03-JUL-06:10 | 40537.60 | 03-JUL-06:19 | 76244.73 | 07-JUL-18:30 | 15178.63 | 08-JUL-10:39 | 0.00 | 01-JUL-00:10 |
August | 93091.76 | 01-AUG-19:10 | 16690.39 | 01-AUG-00:10 | 89674.66 | 01-AUG-06:10 | 40537.60 | 01-AUG-06:19 | 76570.31 | 19-AUG-15:20 | 15105.96 | 19-AUG-10:39 | 0.00 | 01-AUG-00:10 |
September | 93091.76 | 01-SEP-19:10 | 16690.39 | 01-SEP-00:10 | 89674.66 | 01-SEP-06:10 | 40537.60 | 01-SEP-06:19 | 74976.39 | 07-SEP-15:20 | 14979.31 | 09-SEP-10:50 | 0.00 | 01-SEP-00:10 |
October | 93091.76 | 02-OCT-19:10 | 16690.39 | 01-OCT-00:10 | 89674.66 | 02-OCT-06:10 | 40537.60 | 02-OCT-06:19 | 71696.77 | 10-OCT-15:20 | 14597.34 | 11-OCT-16:49 | 0.00 | 01-OCT-00:10 |
November | 93091.76 | 01-NOV-19:10 | 16690.39 | 01-NOV-00:10 | 89674.66 | 01-NOV-06:10 | 40537.60 | 01-NOV-06:19 | 67033.68 | 05-NOV-15:09 | 13756.88 | 27-NOV-19:10 | 0.00 | 01-NOV-00:10 |
December | 93091.76 | 01-DEC-20:10 | 16690.39 | 01-DEC-00:10 | 89674.66 | 01-DEC-07:10 | 40537.60 | 01-DEC-07:19 | 64865.47 | 18-DEC-09:09 | 13226.21 | 13-DEC-11:39 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 93091.76 | 16690.39 | 89674.66 | 40537.60 | 64865.47 | 12639.07 | 0.00 | |||||||
Maximum of Months | 93091.76 | 16690.39 | 89674.66 | 40537.60 | 76570.31 | 15178.63 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum} [W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY {Maximum} [W] | HEATRECOVERY:ELECTRICITY {TIMESTAMP} | WATERSYSTEMS:ELECTRICITY {Maximum} [W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
January | 97817.22 | 31-JAN-15:09 | 0.00 | 0.00 | 17414.08 | 01-JAN-00:10 | 4739.43 | 02-JAN-07:10 | 0.00 |
February | 126823.08 | 28-FEB-16:30 | 0.00 | 0.00 | 17414.08 | 01-FEB-00:20 | 4739.34 | 13-FEB-07:00 | 0.00 |
March | 159748.13 | 30-MAR-18:10 | 0.00 | 0.00 | 17414.08 | 01-MAR-01:10 | 4739.22 | 07-MAR-07:10 | 0.00 |
April | 159880.56 | 21-APR-18:30 | 0.00 | 0.00 | 17414.08 | 01-APR-00:10 | 4738.80 | 28-APR-06:10 | 0.00 |
May | 215795.53 | 30-MAY-18:10 | 0.00 | 0.00 | 17414.08 | 01-MAY-15:20 | 4738.65 | 03-MAY-18:10 | 0.00 |
June | 263150.34 | 28-JUN-18:10 | 0.00 | 0.00 | 17414.08 | 01-JUN-08:20 | 4738.57 | 13-JUN-06:10 | 0.00 |
July | 302320.72 | 08-JUL-15:20 | 0.00 | 0.00 | 17414.08 | 01-JUL-00:10 | 4738.72 | 31-JUL-18:10 | 0.00 |
August | 289364.15 | 01-AUG-15:20 | 0.00 | 0.00 | 17414.08 | 01-AUG-00:10 | 4739.32 | 28-AUG-06:10 | 0.00 |
September | 257554.94 | 07-SEP-15:20 | 0.00 | 0.00 | 17414.08 | 01-SEP-10:00 | 4738.53 | 18-SEP-06:30 | 0.00 |
October | 202456.99 | 18-OCT-18:10 | 0.00 | 0.00 | 17414.08 | 01-OCT-15:20 | 4738.72 | 02-OCT-06:30 | 0.00 |
November | 150391.31 | 27-NOV-19:10 | 0.00 | 0.00 | 17414.08 | 01-NOV-00:10 | 4739.38 | 08-NOV-07:10 | 0.00 |
December | 123391.58 | 13-DEC-11:39 | 0.00 | 0.00 | 17414.08 | 01-DEC-00:10 | 4738.99 | 18-DEC-07:00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 97817.22 | 0.00 | 0.00 | 17414.08 | 4738.53 | 0.00 | |||
Maximum of Months | 302320.72 | 0.00 | 0.00 | 17414.08 | 4739.43 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 401780.54 | 19-JAN-20:10 | 93091.76 | 88971.67 | 16690.39 | 33012.66 | 55296.36 | 11640.53 | 0.00 | 96105.13 | 0.00 |
February | 411315.25 | 28-FEB-20:49 | 93091.76 | 88971.67 | 16690.39 | 33025.38 | 59883.74 | 12111.28 | 0.00 | 101149.77 | 0.00 |
March | 480899.41 | 30-MAR-19:10 | 93091.76 | 88971.67 | 16690.39 | 33012.66 | 65050.35 | 13582.71 | 0.00 | 146376.30 | 0.00 |
April | 480955.87 | 04-APR-19:00 | 93091.76 | 88971.67 | 16690.39 | 33025.38 | 64576.11 | 13551.33 | 0.00 | 147695.92 | 0.00 |
May | 525494.58 | 30-MAY-19:40 | 93091.76 | 88971.67 | 16690.39 | 33025.38 | 66419.64 | 14263.53 | 0.00 | 189561.42 | 0.00 |
June | 571118.19 | 28-JUN-18:10 | 82800.17 | 79617.06 | 0.00 | 32686.23 | 73174.74 | 14798.01 | 0.00 | 263150.34 | 0.00 |
July | 598797.30 | 06-JUL-18:10 | 82800.17 | 79617.06 | 0.00 | 32686.23 | 74997.37 | 14918.84 | 0.00 | 288716.47 | 0.00 |
August | 598806.25 | 02-AUG-19:40 | 93091.76 | 88971.67 | 16690.39 | 33025.38 | 69966.08 | 14658.52 | 0.00 | 258272.68 | 0.00 |
September | 564622.59 | 07-SEP-19:10 | 93091.76 | 88971.67 | 16690.39 | 33012.66 | 68519.98 | 14573.85 | 0.00 | 225779.71 | 0.00 |
October | 534298.57 | 18-OCT-19:00 | 93091.76 | 88971.67 | 16690.39 | 33025.38 | 65133.44 | 14427.84 | 0.00 | 198880.11 | 0.00 |
November | 463679.64 | 27-NOV-20:10 | 93091.76 | 88971.67 | 16690.39 | 33012.66 | 58044.25 | 13546.04 | 0.00 | 137771.72 | 0.00 |
December | 397877.56 | 12-DEC-20:10 | 93091.76 | 88971.67 | 16690.39 | 33012.66 | 58308.63 | 11717.30 | 0.00 | 89775.08 | 0.00 |
Annual Sum or Average | 0.00 | ||||||||||
Minimum of Months | 397877.56 | 82800.17 | 79617.06 | 0.00 | 32686.23 | 55296.36 | 11640.53 | 0.00 | 89775.08 | 0.00 | |
Maximum of Months | 598806.25 | 93091.76 | 88971.67 | 16690.39 | 33025.38 | 74997.37 | 14918.84 | 0.00 | 288716.47 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS {Maximum} [W] | INTERIOREQUIPMENT:NATURALGAS {TIMESTAMP} | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS {Maximum} [W] | HEATING:NATURALGAS {TIMESTAMP} | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS {Maximum} [W] | WATERSYSTEMS:NATURALGAS {TIMESTAMP} | COGENERATION:NATURALGAS [] | |
January | 104248.32 | 02-JAN-18:10 | 0.00 | 284253.45 | 07-JAN-16:19 | 0.00 | 271327.29 | 19-JAN-21:00 | 0.00 |
February | 104248.32 | 01-FEB-18:10 | 0.00 | 345449.91 | 12-FEB-07:10 | 0.00 | 273976.11 | 10-FEB-21:19 | 0.00 |
March | 104248.32 | 01-MAR-18:10 | 0.00 | 131180.50 | 23-MAR-08:09 | 0.00 | 254315.47 | 02-MAR-21:00 | 0.00 |
April | 104248.32 | 01-APR-17:10 | 0.00 | 119377.07 | 06-APR-08:09 | 0.00 | 249254.39 | 03-APR-20:19 | 0.00 |
May | 104248.32 | 01-MAY-17:10 | 0.00 | 100619.33 | 11-MAY-10:39 | 0.00 | 247185.26 | 01-MAY-20:30 | 0.00 |
June | 104248.32 | 01-JUN-17:10 | 0.00 | 97583.49 | 08-JUN-10:39 | 0.00 | 235369.33 | 02-JUN-17:10 | 0.00 |
July | 104248.32 | 01-JUL-17:10 | 0.00 | 90116.40 | 03-JUL-10:39 | 0.00 | 217065.42 | 03-JUL-20:00 | 0.00 |
August | 104248.32 | 01-AUG-17:10 | 0.00 | 88229.08 | 08-AUG-10:39 | 0.00 | 216924.59 | 31-AUG-20:49 | 0.00 |
September | 104248.32 | 01-SEP-17:10 | 0.00 | 84477.04 | 01-SEP-10:39 | 0.00 | 232706.16 | 29-SEP-17:30 | 0.00 |
October | 104248.32 | 02-OCT-17:10 | 0.00 | 117645.12 | 26-OCT-08:09 | 0.00 | 246748.95 | 30-OCT-20:19 | 0.00 |
November | 104248.32 | 01-NOV-17:10 | 0.00 | 154537.02 | 22-NOV-07:10 | 0.00 | 249073.63 | 30-NOV-21:30 | 0.00 |
December | 104248.32 | 01-DEC-18:10 | 0.00 | 198036.54 | 18-DEC-07:40 | 0.00 | 252583.69 | 27-DEC-21:00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 104248.32 | 0.00 | 84477.04 | 0.00 | 216924.59 | 0.00 | |||
Maximum of Months | 104248.32 | 0.00 | 345449.91 | 0.00 | 273976.11 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: BASEMENT
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 1.67 | 20.43 | 1.67 | 20.43 | 0.00 | 20.43 | 0.00 | 20.43 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1.67 | 20.43 | 1.67 | 20.43 | 0.00 | 20.43 | 0.00 | 20.43 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1.67 | 20.43 | 1.67 | 20.43 | 0.00 | 20.43 | 0.00 | 20.43 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: RETAIL_1_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 6.33 | 20.32 | 6.33 | 20.32 | 0.00 | 20.32 | 0.00 | 20.32 |
February | 7.50 | 20.01 | 7.50 | 20.01 | 0.00 | 20.01 | 0.00 | 20.01 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 13.83 | 20.15 | 13.83 | 20.15 | 0.00 | 20.15 | 0.00 | 20.15 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 7.50 | 20.32 | 7.50 | 20.32 | 0.00 | 20.32 | 0.00 | 20.32 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: RETAIL_2_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: MECH_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: STORAGE_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: LAUNDRY_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.70 | 0.33 | 24.70 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.33 | 24.70 | 0.33 | 24.70 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.70 | 0.33 | 24.70 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CAFE_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: LOBBY_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_1_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_2_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.17 | 20.52 | 0.17 | 20.52 | 0.00 | 20.52 | 0.00 | 20.52 |
February | 0.33 | 20.48 | 0.33 | 20.48 | 0.00 | 20.48 | 0.00 | 20.48 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 21.71 | 0.17 | 21.71 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.50 | 20.49 | 0.50 | 20.49 | 0.17 | 20.67 | 0.17 | 20.80 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.33 | 20.52 | 0.33 | 20.52 | 0.17 | 21.71 | 0.17 | 21.71 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.83 | 20.41 | 0.83 | 20.41 | 0.00 | 20.41 | 0.00 | 20.41 |
February | 0.33 | 20.39 | 0.33 | 20.39 | 0.00 | 20.39 | 0.00 | 20.39 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 21.68 | 0.17 | 21.68 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 1.67 | 21.69 | 1.67 | 21.69 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 21.68 | 0.17 | 21.68 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1.17 | 20.40 | 1.17 | 20.40 | 2.00 | 20.99 | 2.00 | 21.21 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.83 | 20.41 | 0.83 | 20.41 | 1.67 | 21.69 | 1.67 | 21.69 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_5_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.33 | 20.51 | 0.33 | 20.51 | 0.00 | 20.51 | 0.00 | 20.51 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.33 | 20.51 | 0.33 | 20.51 | 0.00 | 20.51 | 0.00 | 20.51 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.33 | 20.51 | 0.33 | 20.51 | 0.00 | 20.51 | 0.00 | 20.51 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_6_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.33 | 20.48 | 0.33 | 20.48 | 0.00 | 20.48 | 0.00 | 20.48 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.33 | 20.48 | 0.33 | 20.48 | 0.00 | 20.48 | 0.00 | 20.48 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.33 | 20.48 | 0.33 | 20.48 | 0.00 | 20.48 | 0.00 | 20.48 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORRIDOR_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_1_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.33 | 20.54 | 0.33 | 20.54 | 0.00 | 20.54 | 0.00 | 20.54 |
February | 0.17 | 20.51 | 0.17 | 20.51 | 0.00 | 20.51 | 0.00 | 20.51 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 21.69 | 0.33 | 21.69 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 21.71 | 0.17 | 21.71 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 21.67 | 0.33 | 21.67 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 21.70 | 0.33 | 21.70 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.50 | 20.53 | 0.50 | 20.53 | 1.17 | 21.15 | 1.17 | 21.34 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.33 | 20.54 | 0.33 | 20.54 | 0.33 | 21.71 | 0.33 | 21.71 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_2_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.50 | 20.52 | 0.50 | 20.52 | 0.00 | 20.52 | 0.00 | 20.52 |
February | 0.33 | 20.39 | 0.33 | 20.39 | 0.00 | 20.39 | 0.00 | 20.39 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 21.77 | 0.17 | 21.77 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 21.68 | 0.17 | 21.68 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.83 | 20.47 | 0.83 | 20.47 | 0.33 | 20.68 | 0.33 | 20.83 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.50 | 20.52 | 0.50 | 20.52 | 0.17 | 21.77 | 0.17 | 21.77 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.17 | 20.53 | 0.17 | 20.53 | 0.00 | 20.53 | 0.00 | 20.53 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 21.72 | 0.50 | 21.72 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 21.67 | 0.17 | 21.67 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 21.72 | 1.33 | 21.72 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 | 21.76 | 1.17 | 21.76 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 1.67 | 21.81 | 1.67 | 21.81 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.17 | 20.53 | 0.17 | 20.53 | 4.83 | 21.68 | 4.83 | 21.72 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.17 | 20.53 | 0.17 | 20.53 | 1.67 | 21.81 | 1.67 | 21.81 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: BANQUET_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: DINING_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: KITCHEN_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.64 | 0.83 | 24.64 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.66 | 0.33 | 24.66 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.64 | 0.50 | 24.64 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 24.67 | 1.00 | 24.67 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.63 | 0.33 | 24.63 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 3.00 | 24.65 | 3.00 | 24.65 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 24.67 | 1.00 | 24.67 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORRIDOR_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 4.67 | 20.33 | 4.67 | 20.33 | 0.00 | 20.33 | 0.00 | 20.33 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 4.67 | 20.33 | 4.67 | 20.33 | 0.00 | 20.33 | 0.00 | 20.33 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 4.67 | 20.33 | 4.67 | 20.33 | 0.00 | 20.33 | 0.00 | 20.33 |
Report: ComfortReportSimple55Monthly
For: BASEMENT
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 21.07 | 48.67 | 21.07 | 48.67 | 21.07 |
February | 672.00 | 21.04 | 94.67 | 21.03 | 94.67 | 21.03 |
March | 744.00 | 21.00 | 60.67 | 21.00 | 60.67 | 20.99 |
April | 720.00 | 20.92 | 25.50 | 20.91 | 25.50 | 20.91 |
May | 744.00 | 20.96 | 0.00 | 20.96 | 0.00 | 20.96 |
June | 720.00 | 21.02 | 0.00 | 21.02 | 0.00 | 21.02 |
July | 744.00 | 21.05 | 0.00 | 21.05 | 0.00 | 21.05 |
August | 744.00 | 21.13 | 0.00 | 21.13 | 0.00 | 21.13 |
September | 720.00 | 21.31 | 0.00 | 21.31 | 0.00 | 21.31 |
October | 744.00 | 21.47 | 0.00 | 21.47 | 0.00 | 21.47 |
November | 720.00 | 21.59 | 0.00 | 21.59 | 0.00 | 21.59 |
December | 744.00 | 21.29 | 0.00 | 21.29 | 0.00 | 21.29 |
Annual Sum or Average | 8760.00 | 21.15 | 229.50 | 21.15 | 229.50 | 21.14 |
Minimum of Months | 672.00 | 20.92 | 0.00 | 20.91 | 0.00 | 20.91 |
Maximum of Months | 744.00 | 21.59 | 94.67 | 21.59 | 94.67 | 21.59 |
Report: ComfortReportSimple55Monthly
For: RETAIL_1_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 20.99 | 424.50 | 20.98 | 424.50 | 20.98 |
February | 672.00 | 21.02 | 244.17 | 21.00 | 244.17 | 20.99 |
March | 743.33 | 21.05 | 67.00 | 21.04 | 67.00 | 21.04 |
April | 720.00 | 21.05 | 21.83 | 21.05 | 21.83 | 21.05 |
May | 744.00 | 21.03 | 0.00 | 21.03 | 0.00 | 21.03 |
June | 720.00 | 21.08 | 0.00 | 21.08 | 0.00 | 21.08 |
July | 744.00 | 21.15 | 0.00 | 21.15 | 0.00 | 21.15 |
August | 733.17 | 21.22 | 0.00 | 21.22 | 0.00 | 21.22 |
September | 702.83 | 21.12 | 1.83 | 21.12 | 0.00 | 21.12 |
October | 727.50 | 21.10 | 10.50 | 21.11 | 5.00 | 21.11 |
November | 720.00 | 21.08 | 87.67 | 21.07 | 87.67 | 21.07 |
December | 744.00 | 21.03 | 261.83 | 21.02 | 261.83 | 21.02 |
Annual Sum or Average | 8714.83 | 21.08 | 1119.33 | 21.07 | 1112.00 | 21.06 |
Minimum of Months | 672.00 | 20.99 | 0.00 | 20.98 | 0.00 | 20.98 |
Maximum of Months | 744.00 | 21.22 | 424.50 | 21.22 | 424.50 | 21.22 |
Report: ComfortReportSimple55Monthly
For: RETAIL_2_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 21.00 | 111.67 | 21.00 | 111.67 | 21.00 |
February | 672.00 | 21.02 | 99.17 | 21.01 | 99.17 | 21.01 |
March | 744.00 | 21.06 | 0.00 | 21.06 | 0.00 | 21.06 |
April | 720.00 | 21.08 | 0.00 | 21.08 | 0.00 | 21.08 |
May | 744.00 | 21.12 | 0.00 | 21.12 | 0.00 | 21.12 |
June | 720.00 | 21.21 | 0.00 | 21.21 | 0.00 | 21.21 |
July | 744.00 | 21.25 | 0.00 | 21.25 | 0.00 | 21.25 |
August | 744.00 | 21.28 | 0.00 | 21.28 | 0.00 | 21.28 |
September | 720.00 | 21.15 | 0.00 | 21.15 | 0.00 | 21.15 |
October | 744.00 | 21.07 | 0.00 | 21.07 | 0.00 | 21.07 |
November | 720.00 | 21.03 | 0.00 | 21.03 | 0.00 | 21.03 |
December | 744.00 | 21.01 | 19.00 | 21.01 | 19.00 | 21.01 |
Annual Sum or Average | 8760.00 | 21.11 | 229.83 | 21.10 | 229.83 | 21.10 |
Minimum of Months | 672.00 | 21.00 | 0.00 | 21.00 | 0.00 | 21.00 |
Maximum of Months | 744.00 | 21.28 | 111.67 | 21.28 | 111.67 | 21.28 |
Report: ComfortReportSimple55Monthly
For: MECH_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 21.00 | 394.00 | 21.00 | 394.00 | 21.00 |
February | 672.00 | 21.00 | 206.17 | 21.00 | 206.17 | 20.99 |
March | 744.00 | 21.00 | 46.67 | 21.00 | 46.67 | 21.00 |
April | 720.00 | 21.01 | 1.83 | 21.01 | 1.83 | 21.01 |
May | 744.00 | 21.04 | 0.00 | 21.04 | 0.00 | 21.04 |
June | 720.00 | 21.11 | 0.00 | 21.11 | 0.00 | 21.11 |
July | 744.00 | 21.15 | 0.00 | 21.15 | 0.00 | 21.15 |
August | 744.00 | 21.15 | 0.00 | 21.15 | 0.00 | 21.15 |
September | 720.00 | 21.05 | 0.00 | 21.05 | 0.00 | 21.05 |
October | 744.00 | 21.01 | 0.00 | 21.01 | 0.00 | 21.01 |
November | 720.00 | 21.00 | 30.83 | 21.00 | 30.83 | 21.00 |
December | 744.00 | 21.00 | 191.83 | 21.00 | 191.83 | 21.00 |
Annual Sum or Average | 8760.00 | 21.04 | 871.33 | 21.04 | 871.33 | 21.04 |
Minimum of Months | 672.00 | 21.00 | 0.00 | 21.00 | 0.00 | 20.99 |
Maximum of Months | 744.00 | 21.15 | 394.00 | 21.15 | 394.00 | 21.15 |
Report: ComfortReportSimple55Monthly
For: STORAGE_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 20.99 | 475.83 | 20.99 | 475.83 | 20.99 |
February | 672.00 | 20.99 | 255.50 | 20.98 | 255.50 | 20.98 |
March | 744.00 | 21.00 | 76.67 | 21.00 | 76.67 | 21.00 |
April | 720.00 | 21.00 | 4.67 | 21.00 | 4.67 | 21.00 |
May | 744.00 | 21.01 | 0.00 | 21.01 | 0.00 | 21.01 |
June | 720.00 | 21.04 | 0.00 | 21.04 | 0.00 | 21.04 |
July | 744.00 | 21.08 | 0.00 | 21.08 | 0.00 | 21.08 |
August | 744.00 | 21.08 | 0.00 | 21.08 | 0.00 | 21.08 |
September | 720.00 | 21.01 | 0.00 | 21.01 | 0.00 | 21.01 |
October | 744.00 | 21.00 | 0.00 | 21.00 | 0.00 | 21.00 |
November | 720.00 | 21.00 | 75.50 | 21.00 | 75.50 | 21.00 |
December | 744.00 | 21.00 | 270.33 | 21.00 | 270.33 | 21.00 |
Annual Sum or Average | 8760.00 | 21.02 | 1158.50 | 21.01 | 1158.50 | 21.01 |
Minimum of Months | 672.00 | 20.99 | 0.00 | 20.98 | 0.00 | 20.98 |
Maximum of Months | 744.00 | 21.08 | 475.83 | 21.08 | 475.83 | 21.08 |
Report: ComfortReportSimple55Monthly
For: LAUNDRY_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 558.00 | 21.34 | 157.83 | 21.68 | 68.67 | 21.86 |
February | 470.17 | 21.40 | 156.50 | 21.73 | 72.00 | 21.93 |
March | 426.00 | 21.57 | 225.83 | 21.85 | 96.83 | 22.06 |
April | 287.67 | 21.82 | 289.83 | 21.90 | 99.50 | 22.11 |
May | 180.83 | 22.39 | 478.33 | 21.82 | 109.67 | 22.03 |
June | 138.50 | 22.71 | 523.50 | 21.77 | 106.50 | 21.97 |
July | 118.50 | 22.95 | 603.33 | 21.69 | 109.17 | 21.88 |
August | 117.67 | 23.09 | 612.67 | 21.72 | 112.33 | 21.92 |
September | 150.33 | 22.61 | 492.33 | 21.80 | 106.67 | 22.01 |
October | 319.17 | 21.79 | 322.83 | 21.86 | 104.83 | 22.08 |
November | 427.83 | 21.53 | 210.50 | 21.82 | 87.83 | 22.03 |
December | 513.33 | 21.40 | 175.00 | 21.73 | 76.17 | 21.92 |
Annual Sum or Average | 3708.00 | 21.74 | 4248.50 | 21.78 | 1150.17 | 21.98 |
Minimum of Months | 117.67 | 21.34 | 156.50 | 21.68 | 68.67 | 21.86 |
Maximum of Months | 558.00 | 23.09 | 612.67 | 21.90 | 112.33 | 22.11 |
Report: ComfortReportSimple55Monthly
For: CAFE_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 21.02 | 179.00 | 21.01 | 179.00 | 21.01 |
February | 672.00 | 21.05 | 94.17 | 21.05 | 94.17 | 21.04 |
March | 744.00 | 21.11 | 3.83 | 21.11 | 3.83 | 21.11 |
April | 720.00 | 21.14 | 0.00 | 21.14 | 0.00 | 21.14 |
May | 744.00 | 21.19 | 0.00 | 21.19 | 0.00 | 21.19 |
June | 718.83 | 21.32 | 0.00 | 21.32 | 0.00 | 21.32 |
July | 736.17 | 21.37 | 0.17 | 21.37 | 0.00 | 21.37 |
August | 719.33 | 21.46 | 1.17 | 21.46 | 0.00 | 21.46 |
September | 701.67 | 21.31 | 1.17 | 21.31 | 0.00 | 21.31 |
October | 727.33 | 21.19 | 5.33 | 21.20 | 0.00 | 21.20 |
November | 720.00 | 21.11 | 9.17 | 21.11 | 9.17 | 21.10 |
December | 744.00 | 21.04 | 41.83 | 21.04 | 41.83 | 21.04 |
Annual Sum or Average | 8691.33 | 21.19 | 335.83 | 21.19 | 328.00 | 21.18 |
Minimum of Months | 672.00 | 21.02 | 0.00 | 21.01 | 0.00 | 21.01 |
Maximum of Months | 744.00 | 21.46 | 179.00 | 21.46 | 179.00 | 21.46 |
Report: ComfortReportSimple55Monthly
For: LOBBY_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 21.03 | 13.67 | 21.03 | 13.67 | 21.03 |
February | 672.00 | 21.07 | 24.17 | 21.07 | 24.17 | 21.07 |
March | 744.00 | 21.16 | 0.00 | 21.16 | 0.00 | 21.16 |
April | 720.00 | 21.21 | 0.00 | 21.21 | 0.00 | 21.21 |
May | 744.00 | 21.29 | 0.00 | 21.29 | 0.00 | 21.29 |
June | 720.00 | 21.40 | 0.00 | 21.40 | 0.00 | 21.40 |
July | 744.00 | 21.43 | 0.00 | 21.43 | 0.00 | 21.43 |
August | 744.00 | 21.47 | 0.00 | 21.47 | 0.00 | 21.47 |
September | 720.00 | 21.34 | 0.00 | 21.34 | 0.00 | 21.34 |
October | 744.00 | 21.20 | 0.00 | 21.20 | 0.00 | 21.20 |
November | 720.00 | 21.12 | 0.00 | 21.12 | 0.00 | 21.12 |
December | 744.00 | 21.06 | 0.00 | 21.06 | 0.00 | 21.06 |
Annual Sum or Average | 8760.00 | 21.23 | 37.83 | 21.23 | 37.83 | 21.23 |
Minimum of Months | 672.00 | 21.03 | 0.00 | 21.03 | 0.00 | 21.03 |
Maximum of Months | 744.00 | 21.47 | 24.17 | 21.47 | 24.17 | 21.47 |
Report: ComfortReportSimple55Monthly
For: ROOM_1_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 20.77 | 554.50 | 20.72 | 554.50 | 20.70 |
February | 672.00 | 20.97 | 319.17 | 20.85 | 319.17 | 20.79 |
March | 736.17 | 21.32 | 60.17 | 21.27 | 60.17 | 21.22 |
April | 700.67 | 21.47 | 16.00 | 21.45 | 16.00 | 21.44 |
May | 680.83 | 21.48 | 2.50 | 21.48 | 2.50 | 21.48 |
June | 603.50 | 21.39 | 11.00 | 21.42 | 3.67 | 21.43 |
July | 605.00 | 21.34 | 42.83 | 21.45 | 17.83 | 21.47 |
August | 590.83 | 21.31 | 45.67 | 21.45 | 7.83 | 21.47 |
September | 632.50 | 21.41 | 17.50 | 21.45 | 9.00 | 21.47 |
October | 719.17 | 21.37 | 33.67 | 21.35 | 32.83 | 21.34 |
November | 718.33 | 21.26 | 117.17 | 21.18 | 117.17 | 21.13 |
December | 744.00 | 20.95 | 386.33 | 20.87 | 386.33 | 20.83 |
Annual Sum or Average | 8147.00 | 21.24 | 1606.50 | 21.18 | 1527.00 | 21.12 |
Minimum of Months | 590.83 | 20.77 | 2.50 | 20.72 | 2.50 | 20.70 |
Maximum of Months | 744.00 | 21.48 | 554.50 | 21.48 | 554.50 | 21.48 |
Report: ComfortReportSimple55Monthly
For: ROOM_2_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 20.60 | 621.67 | 20.56 | 621.67 | 20.55 |
February | 672.00 | 20.81 | 361.00 | 20.70 | 361.00 | 20.65 |
March | 741.00 | 21.16 | 113.50 | 21.09 | 113.50 | 21.03 |
April | 711.83 | 21.43 | 24.83 | 21.40 | 24.83 | 21.38 |
May | 693.67 | 21.49 | 3.00 | 21.49 | 3.00 | 21.49 |
June | 607.83 | 21.41 | 10.50 | 21.44 | 3.50 | 21.44 |
July | 608.50 | 21.35 | 39.33 | 21.45 | 17.67 | 21.47 |
August | 600.17 | 21.34 | 33.67 | 21.43 | 9.00 | 21.45 |
September | 662.00 | 21.46 | 16.17 | 21.50 | 13.83 | 21.52 |
October | 737.67 | 21.25 | 50.67 | 21.22 | 50.67 | 21.19 |
November | 720.00 | 21.03 | 207.17 | 20.94 | 207.17 | 20.88 |
December | 744.00 | 20.71 | 531.00 | 20.65 | 531.00 | 20.62 |
Annual Sum or Average | 8242.67 | 21.16 | 2012.50 | 21.06 | 1956.83 | 20.99 |
Minimum of Months | 600.17 | 20.60 | 3.00 | 20.56 | 3.00 | 20.55 |
Maximum of Months | 744.00 | 21.49 | 621.67 | 21.50 | 621.67 | 21.52 |
Report: ComfortReportSimple55Monthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 20.86 | 476.17 | 20.80 | 476.17 | 20.78 |
February | 672.00 | 21.01 | 244.83 | 20.92 | 244.83 | 20.87 |
March | 744.00 | 21.24 | 20.00 | 21.24 | 20.00 | 21.23 |
April | 720.00 | 21.40 | 0.00 | 21.40 | 0.00 | 21.40 |
May | 744.00 | 21.53 | 0.17 | 21.53 | 0.17 | 21.53 |
June | 720.00 | 21.65 | 3.00 | 21.65 | 3.00 | 21.66 |
July | 744.00 | 21.66 | 8.83 | 21.67 | 8.83 | 21.68 |
August | 744.00 | 21.66 | 11.17 | 21.67 | 11.17 | 21.68 |
September | 720.00 | 21.53 | 2.50 | 21.53 | 2.50 | 21.53 |
October | 744.00 | 21.30 | 4.33 | 21.30 | 4.33 | 21.31 |
November | 720.00 | 21.17 | 52.00 | 21.15 | 52.00 | 21.13 |
December | 744.00 | 21.00 | 253.50 | 20.95 | 253.50 | 20.91 |
Annual Sum or Average | 8760.00 | 21.34 | 1076.50 | 21.27 | 1076.50 | 21.23 |
Minimum of Months | 672.00 | 20.86 | 0.00 | 20.80 | 0.00 | 20.78 |
Maximum of Months | 744.00 | 21.66 | 476.17 | 21.67 | 476.17 | 21.68 |
Report: ComfortReportSimple55Monthly
For: ROOM_5_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 20.80 | 545.67 | 20.75 | 545.67 | 20.73 |
February | 672.00 | 21.02 | 310.33 | 20.90 | 310.33 | 20.84 |
March | 740.33 | 21.41 | 50.50 | 21.37 | 50.50 | 21.34 |
April | 694.50 | 21.54 | 12.33 | 21.53 | 12.33 | 21.52 |
May | 654.17 | 21.46 | 2.33 | 21.46 | 2.33 | 21.46 |
June | 577.33 | 21.35 | 3.17 | 21.36 | 2.17 | 21.36 |
July | 571.33 | 21.25 | 20.33 | 21.29 | 12.83 | 21.31 |
August | 567.17 | 21.24 | 14.83 | 21.29 | 6.00 | 21.31 |
September | 614.67 | 21.38 | 10.33 | 21.40 | 9.50 | 21.43 |
October | 713.83 | 21.41 | 36.17 | 21.39 | 36.17 | 21.37 |
November | 720.00 | 21.30 | 106.00 | 21.24 | 106.00 | 21.19 |
December | 744.00 | 20.97 | 367.17 | 20.90 | 367.17 | 20.86 |
Annual Sum or Average | 8013.33 | 21.25 | 1479.17 | 21.18 | 1461.00 | 21.13 |
Minimum of Months | 567.17 | 20.80 | 2.33 | 20.75 | 2.17 | 20.73 |
Maximum of Months | 744.00 | 21.54 | 545.67 | 21.53 | 545.67 | 21.52 |
Report: ComfortReportSimple55Monthly
For: ROOM_6_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 20.61 | 613.17 | 20.57 | 613.17 | 20.56 |
February | 672.00 | 20.85 | 341.83 | 20.74 | 341.83 | 20.68 |
March | 744.00 | 21.25 | 87.00 | 21.21 | 87.00 | 21.17 |
April | 720.00 | 21.55 | 14.83 | 21.54 | 14.83 | 21.53 |
May | 668.67 | 21.49 | 2.83 | 21.50 | 2.83 | 21.50 |
June | 578.00 | 21.35 | 3.50 | 21.36 | 2.17 | 21.37 |
July | 572.33 | 21.25 | 19.33 | 21.30 | 12.00 | 21.31 |
August | 571.50 | 21.26 | 9.17 | 21.29 | 7.50 | 21.31 |
September | 652.17 | 21.48 | 12.50 | 21.51 | 12.17 | 21.53 |
October | 741.17 | 21.34 | 46.00 | 21.32 | 46.00 | 21.29 |
November | 720.00 | 21.04 | 186.83 | 20.97 | 186.83 | 20.92 |
December | 744.00 | 20.72 | 517.17 | 20.66 | 517.17 | 20.63 |
Annual Sum or Average | 8127.83 | 21.17 | 1854.17 | 21.07 | 1843.50 | 21.00 |
Minimum of Months | 571.50 | 20.61 | 2.83 | 20.57 | 2.17 | 20.56 |
Maximum of Months | 744.00 | 21.55 | 613.17 | 21.54 | 613.17 | 21.53 |
Report: ComfortReportSimple55Monthly
For: CORRIDOR_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 21.00 | 400.67 | 21.00 | 400.67 | 21.00 |
February | 672.00 | 21.01 | 216.83 | 21.01 | 216.83 | 21.00 |
March | 744.00 | 21.04 | 49.67 | 21.04 | 49.67 | 21.03 |
April | 720.00 | 21.12 | 0.00 | 21.12 | 0.00 | 21.12 |
May | 744.00 | 21.28 | 0.00 | 21.28 | 0.00 | 21.28 |
June | 720.00 | 21.74 | 0.00 | 21.74 | 0.00 | 21.74 |
July | 744.00 | 21.93 | 0.00 | 21.93 | 0.00 | 21.93 |
August | 744.00 | 22.01 | 0.00 | 22.01 | 0.00 | 22.01 |
September | 720.00 | 21.53 | 0.00 | 21.53 | 0.00 | 21.53 |
October | 744.00 | 21.10 | 0.00 | 21.10 | 0.00 | 21.10 |
November | 720.00 | 21.01 | 33.33 | 21.01 | 33.33 | 21.01 |
December | 744.00 | 21.00 | 189.67 | 21.00 | 189.67 | 21.00 |
Annual Sum or Average | 8760.00 | 21.32 | 890.17 | 21.29 | 890.17 | 21.26 |
Minimum of Months | 672.00 | 21.00 | 0.00 | 21.00 | 0.00 | 21.00 |
Maximum of Months | 744.00 | 22.01 | 400.67 | 22.01 | 400.67 | 22.01 |
Report: ComfortReportSimple55Monthly
For: ROOM_1_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 20.67 | 605.17 | 20.63 | 605.17 | 20.61 |
February | 671.83 | 20.90 | 359.83 | 20.77 | 359.83 | 20.72 |
March | 731.83 | 21.27 | 123.50 | 21.19 | 123.33 | 21.13 |
April | 672.17 | 21.39 | 36.83 | 21.37 | 35.67 | 21.34 |
May | 640.67 | 21.38 | 32.00 | 21.43 | 15.00 | 21.43 |
June | 578.33 | 21.32 | 68.17 | 21.52 | 8.83 | 21.54 |
July | 585.33 | 21.29 | 120.50 | 21.60 | 25.17 | 21.62 |
August | 574.50 | 21.27 | 126.83 | 21.63 | 15.00 | 21.65 |
September | 606.67 | 21.33 | 48.83 | 21.46 | 12.83 | 21.48 |
October | 706.83 | 21.30 | 68.33 | 21.28 | 62.17 | 21.25 |
November | 717.83 | 21.19 | 198.50 | 21.09 | 198.50 | 21.03 |
December | 744.00 | 20.84 | 509.00 | 20.76 | 509.00 | 20.73 |
Annual Sum or Average | 7974.00 | 21.17 | 2297.50 | 21.14 | 1970.50 | 21.07 |
Minimum of Months | 574.50 | 20.67 | 32.00 | 20.63 | 8.83 | 20.61 |
Maximum of Months | 744.00 | 21.39 | 605.17 | 21.63 | 605.17 | 21.65 |
Report: ComfortReportSimple55Monthly
For: ROOM_2_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 20.55 | 647.50 | 20.52 | 647.50 | 20.51 |
February | 672.00 | 20.76 | 407.00 | 20.66 | 407.00 | 20.62 |
March | 738.83 | 21.12 | 191.00 | 21.02 | 191.00 | 20.96 |
April | 690.67 | 21.38 | 44.33 | 21.34 | 44.33 | 21.31 |
May | 649.83 | 21.39 | 27.17 | 21.42 | 16.50 | 21.42 |
June | 580.17 | 21.33 | 60.83 | 21.51 | 8.50 | 21.52 |
July | 586.17 | 21.29 | 110.00 | 21.57 | 25.83 | 21.59 |
August | 579.83 | 21.28 | 105.67 | 21.58 | 14.67 | 21.60 |
September | 629.33 | 21.38 | 30.33 | 21.45 | 13.83 | 21.47 |
October | 728.17 | 21.21 | 82.00 | 21.15 | 82.00 | 21.10 |
November | 719.50 | 20.97 | 302.33 | 20.87 | 302.33 | 20.82 |
December | 744.00 | 20.62 | 601.83 | 20.57 | 601.83 | 20.55 |
Annual Sum or Average | 8062.50 | 21.09 | 2610.00 | 21.03 | 2355.33 | 20.95 |
Minimum of Months | 579.83 | 20.55 | 27.17 | 20.52 | 8.50 | 20.51 |
Maximum of Months | 744.00 | 21.39 | 647.50 | 21.58 | 647.50 | 21.60 |
Report: ComfortReportSimple55Monthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 21.12 | 376.67 | 21.00 | 376.67 | 20.94 |
February | 667.83 | 21.21 | 238.17 | 21.09 | 238.17 | 21.02 |
March | 724.33 | 21.42 | 42.83 | 21.38 | 42.83 | 21.35 |
April | 678.17 | 21.46 | 16.00 | 21.45 | 16.00 | 21.44 |
May | 669.33 | 21.46 | 3.17 | 21.46 | 3.17 | 21.46 |
June | 608.83 | 21.41 | 8.00 | 21.42 | 8.00 | 21.44 |
July | 608.67 | 21.35 | 20.17 | 21.38 | 20.17 | 21.41 |
August | 593.50 | 21.32 | 48.67 | 21.45 | 15.83 | 21.47 |
September | 612.17 | 21.37 | 23.00 | 21.43 | 7.17 | 21.44 |
October | 673.50 | 21.35 | 33.00 | 21.36 | 23.17 | 21.34 |
November | 692.33 | 21.41 | 56.67 | 21.36 | 56.67 | 21.32 |
December | 735.83 | 21.25 | 209.33 | 21.15 | 209.33 | 21.09 |
Annual Sum or Average | 8008.50 | 21.34 | 1075.67 | 21.30 | 1017.17 | 21.26 |
Minimum of Months | 593.50 | 21.12 | 3.17 | 21.00 | 3.17 | 20.94 |
Maximum of Months | 744.00 | 21.46 | 376.67 | 21.46 | 376.67 | 21.47 |
Report: ComfortReportSimple55Monthly
For: BANQUET_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 21.22 | 6.33 | 21.22 | 6.33 | 21.21 |
February | 672.00 | 21.32 | 22.17 | 21.31 | 22.17 | 21.30 |
March | 736.67 | 21.48 | 2.33 | 21.48 | 0.00 | 21.48 |
April | 705.00 | 21.56 | 1.83 | 21.56 | 0.00 | 21.56 |
May | 680.00 | 21.63 | 25.50 | 21.68 | 0.00 | 21.68 |
June | 575.83 | 21.67 | 54.50 | 21.80 | 0.00 | 21.80 |
July | 558.17 | 21.65 | 76.17 | 21.82 | 0.00 | 21.82 |
August | 529.67 | 21.62 | 81.00 | 21.81 | 0.00 | 21.81 |
September | 655.50 | 21.62 | 22.17 | 21.67 | 0.00 | 21.67 |
October | 729.50 | 21.49 | 5.00 | 21.50 | 0.00 | 21.50 |
November | 716.17 | 21.39 | 0.00 | 21.39 | 0.00 | 21.39 |
December | 744.00 | 21.29 | 0.00 | 21.29 | 0.00 | 21.29 |
Annual Sum or Average | 8046.50 | 21.48 | 297.00 | 21.53 | 28.50 | 21.53 |
Minimum of Months | 529.67 | 21.22 | 0.00 | 21.22 | 0.00 | 21.21 |
Maximum of Months | 744.00 | 21.67 | 81.00 | 21.82 | 22.17 | 21.82 |
Report: ComfortReportSimple55Monthly
For: DINING_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 742.00 | 21.25 | 0.00 | 21.25 | 0.00 | 21.25 |
February | 669.83 | 21.35 | 3.83 | 21.35 | 3.83 | 21.35 |
March | 727.50 | 21.52 | 6.17 | 21.53 | 0.00 | 21.53 |
April | 675.50 | 21.58 | 10.33 | 21.60 | 0.00 | 21.60 |
May | 632.50 | 21.64 | 52.00 | 21.75 | 0.00 | 21.75 |
June | 479.00 | 21.62 | 96.00 | 21.85 | 0.00 | 21.85 |
July | 452.00 | 21.58 | 127.67 | 21.89 | 0.00 | 21.89 |
August | 433.67 | 21.54 | 133.67 | 21.88 | 0.00 | 21.88 |
September | 589.33 | 21.60 | 49.17 | 21.71 | 0.00 | 21.71 |
October | 715.67 | 21.52 | 12.67 | 21.55 | 0.00 | 21.55 |
November | 709.67 | 21.42 | 1.67 | 21.43 | 0.00 | 21.43 |
December | 741.00 | 21.32 | 0.00 | 21.32 | 0.00 | 21.32 |
Annual Sum or Average | 7567.67 | 21.48 | 493.17 | 21.57 | 3.83 | 21.57 |
Minimum of Months | 433.67 | 21.25 | 0.00 | 21.25 | 0.00 | 21.25 |
Maximum of Months | 742.00 | 21.64 | 133.67 | 21.89 | 3.83 | 21.89 |
Report: ComfortReportSimple55Monthly
For: KITCHEN_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 445.33 | 22.40 | 500.50 | 22.78 | 236.50 | 22.94 |
February | 451.00 | 22.65 | 467.50 | 22.97 | 275.00 | 23.13 |
March | 570.83 | 23.01 | 547.33 | 23.24 | 414.83 | 23.38 |
April | 573.33 | 23.21 | 551.50 | 23.37 | 450.67 | 23.49 |
May | 561.83 | 23.55 | 602.33 | 23.54 | 503.67 | 23.63 |
June | 524.83 | 23.75 | 623.67 | 23.59 | 500.00 | 23.68 |
July | 524.33 | 23.86 | 666.50 | 23.60 | 520.67 | 23.68 |
August | 522.00 | 23.88 | 680.83 | 23.58 | 522.00 | 23.68 |
September | 524.67 | 23.65 | 602.17 | 23.55 | 492.33 | 23.63 |
October | 575.83 | 23.15 | 571.67 | 23.30 | 450.17 | 23.42 |
November | 540.83 | 22.87 | 525.17 | 23.13 | 373.67 | 23.27 |
December | 502.00 | 22.62 | 520.83 | 22.94 | 307.17 | 23.09 |
Annual Sum or Average | 6316.83 | 23.23 | 6860.00 | 23.32 | 5046.67 | 23.45 |
Minimum of Months | 445.33 | 22.40 | 467.50 | 22.78 | 236.50 | 22.94 |
Maximum of Months | 575.83 | 23.88 | 680.83 | 23.60 | 522.00 | 23.68 |
Report: ComfortReportSimple55Monthly
For: CORRIDOR_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 20.99 | 477.00 | 20.99 | 477.00 | 20.99 |
February | 672.00 | 20.99 | 274.33 | 20.98 | 274.33 | 20.98 |
March | 744.00 | 21.00 | 63.33 | 21.00 | 63.33 | 21.00 |
April | 720.00 | 21.03 | 13.67 | 21.03 | 13.67 | 21.03 |
May | 744.00 | 21.08 | 0.00 | 21.08 | 0.00 | 21.08 |
June | 720.00 | 21.26 | 0.00 | 21.26 | 0.00 | 21.26 |
July | 744.00 | 21.42 | 0.00 | 21.42 | 0.00 | 21.42 |
August | 744.00 | 21.45 | 0.00 | 21.45 | 0.00 | 21.45 |
September | 720.00 | 21.10 | 0.00 | 21.10 | 0.00 | 21.10 |
October | 744.00 | 21.02 | 0.00 | 21.02 | 0.00 | 21.02 |
November | 720.00 | 21.00 | 92.83 | 21.00 | 92.83 | 21.00 |
December | 744.00 | 21.00 | 296.17 | 21.00 | 296.17 | 21.00 |
Annual Sum or Average | 8760.00 | 21.11 | 1217.33 | 21.10 | 1217.33 | 21.09 |
Minimum of Months | 672.00 | 20.99 | 0.00 | 20.98 | 0.00 | 20.98 |
Maximum of Months | 744.00 | 21.45 | 477.00 | 21.45 | 477.00 | 21.45 |
Report: OccupantComfortDataSummaryMonthly
For: BASEMENT PEOPLE
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.07494 | 27.27357 | -0.4479 | 9.33103 |
February | 672.00000 | 21.03564 | 30.61516 | -0.4507 | 9.42727 |
March | 744.00000 | 20.99871 | 38.29281 | -0.4277 | 8.99086 |
April | 720.00000 | 20.91508 | 48.96730 | -0.3996 | 8.49707 |
May | 744.00000 | 20.96066 | 58.62649 | -1.5303 | 52.54974 |
June | 720.00000 | 21.01977 | 59.34916 | -1.4783 | 49.73249 |
July | 744.00000 | 21.04731 | 62.36442 | -1.4341 | 47.35016 |
August | 744.00000 | 21.13449 | 62.06438 | -1.3893 | 44.97329 |
September | 720.00000 | 21.30624 | 60.84967 | -1.3218 | 41.49684 |
October | 744.00000 | 21.47397 | 50.34939 | -0.1853 | 5.84031 |
November | 720.00000 | 21.58858 | 37.41783 | -0.2344 | 6.35246 |
December | 744.00000 | 21.28709 | 31.84656 | -0.3495 | 7.74103 |
Annual Sum or Average | 8760.00000 | 21.15392 | 47.42490 | -0.8064 | 24.45588 |
Minimum of Months | 672.00000 | 20.91508 | 27.27357 | -1.5303 | 5.84031 |
Maximum of Months | 744.00000 | 21.58858 | 62.36442 | -0.1853 | 52.54974 |
Report: OccupantComfortDataSummaryMonthly
For: RETAIL_1_FLR_1 PEOPLE
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 20.99037 | 26.69510 | -0.5421 | 11.63166 |
February | 672.00000 | 21.01856 | 29.97246 | -0.4752 | 10.36913 |
March | 744.00000 | 21.04974 | 37.60219 | -0.3473 | 8.05840 |
April | 720.00000 | 21.04924 | 48.16064 | -0.2608 | 6.88130 |
May | 744.00000 | 21.03006 | 58.26328 | -1.3254 | 41.74903 |
June | 720.00000 | 21.07778 | 59.58766 | -1.2502 | 37.95296 |
July | 744.00000 | 21.14649 | 63.05005 | -1.1880 | 34.91506 |
August | 744.00000 | 21.23800 | 62.99100 | -1.1363 | 32.62721 |
September | 720.00000 | 21.14679 | 61.78074 | -1.2365 | 37.59902 |
October | 744.00000 | 21.12877 | 51.00984 | -0.2255 | 6.70176 |
November | 720.00000 | 21.08144 | 37.95094 | -0.3571 | 8.28736 |
December | 744.00000 | 21.03203 | 31.62194 | -0.4637 | 9.98086 |
Annual Sum or Average | 8760.00000 | 21.08289 | 47.48456 | -0.7357 | 20.62339 |
Minimum of Months | 672.00000 | 20.99037 | 26.69510 | -1.3254 | 6.70176 |
Maximum of Months | 744.00000 | 21.23800 | 63.05005 | -0.2255 | 41.74903 |
Report: OccupantComfortDataSummaryMonthly
For: RETAIL_2_FLR_1 PEOPLE
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.00443 | 27.57613 | -0.4657 | 9.68831 |
February | 672.00000 | 21.01699 | 30.86909 | -0.4279 | 9.06080 |
March | 744.00000 | 21.05518 | 38.43423 | -0.3450 | 7.72886 |
April | 720.00000 | 21.08222 | 48.83861 | -0.2663 | 6.71026 |
May | 744.00000 | 21.12456 | 58.58519 | -1.3446 | 42.68739 |
June | 720.00000 | 21.21403 | 59.49047 | -1.2908 | 39.96019 |
July | 744.00000 | 21.24765 | 62.77137 | -1.2549 | 38.13509 |
August | 744.00000 | 21.28189 | 62.79679 | -1.2381 | 37.29717 |
September | 720.00000 | 21.15055 | 62.16119 | -1.3071 | 40.77428 |
October | 744.00000 | 21.06753 | 51.90412 | -0.2558 | 6.50988 |
November | 720.00000 | 21.02884 | 38.85311 | -0.3580 | 7.88652 |
December | 744.00000 | 21.00959 | 32.53024 | -0.4209 | 8.88694 |
Annual Sum or Average | 8760.00000 | 21.10756 | 47.99226 | -0.7499 | 21.34954 |
Minimum of Months | 672.00000 | 21.00443 | 27.57613 | -1.3446 | 6.50988 |
Maximum of Months | 744.00000 | 21.28189 | 62.79679 | -0.2558 | 42.68739 |
Report: OccupantComfortDataSummaryMonthly
For: LAUNDRY_FLR_1 PEOPLE
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.41581 | 24.93218 | 0.20957 | 8.63050 |
February | 672.00000 | 21.41560 | 28.12271 | 0.25013 | 9.11745 |
March | 744.00000 | 21.42132 | 35.61454 | 0.33187 | 10.06791 |
April | 720.00000 | 21.39398 | 45.93895 | 0.40538 | 11.00896 |
May | 744.00000 | 21.38554 | 55.53616 | -0.3860 | 12.95726 |
June | 720.00000 | 21.37848 | 56.51160 | -0.3534 | 12.33944 |
July | 744.00000 | 21.35580 | 59.72190 | -0.3355 | 11.69257 |
August | 744.00000 | 21.37742 | 59.69409 | -0.3239 | 11.79546 |
September | 720.00000 | 21.38226 | 58.96686 | -0.3663 | 12.50742 |
October | 744.00000 | 21.40306 | 48.80697 | 0.41359 | 11.06517 |
November | 720.00000 | 21.41981 | 35.99168 | 0.31888 | 9.81799 |
December | 744.00000 | 21.41600 | 29.76680 | 0.25536 | 9.07875 |
Annual Sum or Average | 8760.00000 | 21.39698 | 45.05743 | 0.03357 | 10.84772 |
Minimum of Months | 672.00000 | 21.35580 | 24.93218 | -0.3860 | 8.63050 |
Maximum of Months | 744.00000 | 21.42132 | 59.72190 | 0.41359 | 12.95726 |
Report: OccupantComfortDataSummaryMonthly
For: CAFE_FLR_1 PEOPLE
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.01693 | 29.67775 | -0.4308 | 9.28921 |
February | 672.00000 | 21.05302 | 32.91967 | -0.3657 | 8.32051 |
March | 744.00000 | 21.11471 | 40.39102 | -0.2416 | 6.73873 |
April | 720.00000 | 21.13945 | 50.78040 | -0.1563 | 5.94590 |
May | 744.00000 | 21.19357 | 60.42043 | -1.1700 | 34.05730 |
June | 720.00000 | 21.32181 | 61.20563 | -1.0783 | 29.87763 |
July | 744.00000 | 21.38064 | 64.39159 | -1.0212 | 27.33139 |
August | 744.00000 | 21.48680 | 64.17459 | -0.9659 | 25.06231 |
September | 720.00000 | 21.32834 | 63.62479 | -1.0757 | 29.90317 |
October | 744.00000 | 21.20675 | 53.56387 | -0.1188 | 5.82704 |
November | 720.00000 | 21.10669 | 40.79162 | -0.2552 | 6.90556 |
December | 744.00000 | 21.04244 | 34.57534 | -0.3573 | 8.09796 |
Annual Sum or Average | 8760.00000 | 21.20019 | 49.79961 | -0.6046 | 16.49442 |
Minimum of Months | 672.00000 | 21.01693 | 29.67775 | -1.1700 | 5.82704 |
Maximum of Months | 744.00000 | 21.48680 | 64.39159 | -0.1188 | 34.05730 |
Report: OccupantComfortDataSummaryMonthly
For: LOBBY_FLR_1 PEOPLE
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.03137 | 29.20395 | -0.4215 | 8.89686 |
February | 672.00000 | 21.07066 | 32.43917 | -0.3764 | 8.24315 |
March | 744.00000 | 21.16298 | 39.86598 | -0.2817 | 6.97428 |
April | 720.00000 | 21.20702 | 50.13845 | -0.2010 | 6.14931 |
May | 744.00000 | 21.28810 | 59.66375 | -1.2423 | 37.56566 |
June | 720.00000 | 21.39888 | 60.45571 | -1.1785 | 34.53537 |
July | 744.00000 | 21.43031 | 63.66297 | -1.1412 | 32.74227 |
August | 744.00000 | 21.47228 | 63.64971 | -1.1203 | 31.78737 |
September | 720.00000 | 21.33826 | 63.08733 | -1.1927 | 35.15090 |
October | 744.00000 | 21.19617 | 53.15454 | -0.1851 | 5.93092 |
November | 720.00000 | 21.11683 | 40.30215 | -0.2961 | 7.10380 |
December | 744.00000 | 21.05876 | 34.10138 | -0.3689 | 8.06606 |
Annual Sum or Average | 8760.00000 | 21.23191 | 49.23336 | -0.6690 | 18.65714 |
Minimum of Months | 672.00000 | 21.03137 | 29.20395 | -1.2423 | 5.93092 |
Maximum of Months | 744.00000 | 21.47228 | 63.66297 | -0.1851 | 37.56566 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_1_FLR_3 PEOPLE
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 20.77171 | 31.70503 | -0.6233 | 13.84418 |
February | 672.00000 | 20.96668 | 34.91165 | -0.5166 | 11.72421 |
March | 744.00000 | 21.33956 | 40.52793 | -0.3104 | 7.90951 |
April | 720.00000 | 21.51852 | 49.57700 | -0.1742 | 6.56843 |
May | 744.00000 | 21.63280 | 56.06913 | -1.1788 | 35.45363 |
June | 720.00000 | 21.70480 | 55.17329 | -1.0989 | 31.93909 |
July | 744.00000 | 21.70895 | 58.45163 | -1.0596 | 30.19584 |
August | 744.00000 | 21.72534 | 57.93109 | -1.0437 | 29.54590 |
September | 720.00000 | 21.64075 | 58.73244 | -1.1435 | 33.90725 |
October | 744.00000 | 21.43335 | 53.43790 | -0.1954 | 6.70169 |
November | 720.00000 | 21.26072 | 41.95875 | -0.3572 | 8.53668 |
December | 744.00000 | 20.95073 | 36.58108 | -0.5207 | 11.36587 |
Annual Sum or Average | 8760.00000 | 21.38972 | 47.99065 | -0.6865 | 19.02010 |
Minimum of Months | 672.00000 | 20.77171 | 31.70503 | -1.1788 | 6.56843 |
Maximum of Months | 744.00000 | 21.72534 | 58.73244 | -0.1742 | 35.45363 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_2_FLR_3 PEOPLE
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 20.59633 | 31.98290 | -0.6936 | 15.91467 |
February | 672.00000 | 20.80746 | 35.18737 | -0.5805 | 13.19768 |
March | 744.00000 | 21.17364 | 41.05423 | -0.3699 | 8.65814 |
April | 720.00000 | 21.44772 | 49.89918 | -0.2031 | 6.72358 |
May | 744.00000 | 21.61668 | 56.34531 | -1.1902 | 35.91409 |
June | 720.00000 | 21.70603 | 55.19977 | -1.0997 | 31.94900 |
July | 744.00000 | 21.70969 | 58.55558 | -1.0618 | 30.26195 |
August | 744.00000 | 21.72183 | 58.42691 | -1.0548 | 29.95522 |
September | 720.00000 | 21.61181 | 59.62029 | -1.1708 | 35.00846 |
October | 744.00000 | 21.27200 | 54.39687 | -0.2553 | 7.09649 |
November | 720.00000 | 21.03227 | 42.60877 | -0.4397 | 9.79552 |
December | 744.00000 | 20.71154 | 37.06779 | -0.6051 | 13.40971 |
Annual Sum or Average | 8760.00000 | 21.28602 | 48.43234 | -0.7282 | 19.86671 |
Minimum of Months | 672.00000 | 20.59633 | 31.98290 | -1.1902 | 6.72358 |
Maximum of Months | 744.00000 | 21.72183 | 59.62029 | -0.2031 | 35.91409 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_3_MULT19_FLR_3 PEOPLE
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 0.00000 | ||||
Minimum of Months | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_4_MULT19_FLR_3 PEOPLE
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 20.85896 | 31.05203 | -0.5652 | 12.24540 |
February | 672.00000 | 21.00828 | 33.85902 | -0.4881 | 10.63273 |
March | 744.00000 | 21.24213 | 39.67670 | -0.3546 | 7.94405 |
April | 720.00000 | 21.39931 | 48.09640 | -0.2442 | 6.65482 |
May | 744.00000 | 21.52738 | 54.67522 | -1.2837 | 39.94447 |
June | 720.00000 | 21.64763 | 54.52071 | -1.2128 | 36.73338 |
July | 744.00000 | 21.66147 | 57.52783 | -1.1824 | 35.30018 |
August | 744.00000 | 21.66120 | 57.54058 | -1.1847 | 35.39561 |
September | 720.00000 | 21.52757 | 57.30285 | -1.2675 | 39.14693 |
October | 744.00000 | 21.30347 | 52.03759 | -0.2577 | 6.63347 |
November | 720.00000 | 21.17027 | 40.78901 | -0.3825 | 8.38674 |
December | 744.00000 | 21.00103 | 35.74381 | -0.4830 | 10.27017 |
Annual Sum or Average | 8760.00000 | 21.33562 | 46.97312 | -0.7439 | 20.83591 |
Minimum of Months | 672.00000 | 20.85896 | 31.05203 | -1.2837 | 6.63347 |
Maximum of Months | 744.00000 | 21.66147 | 57.54058 | -0.2442 | 39.94447 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_5_FLR_3 PEOPLE
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 20.79795 | 31.64771 | -0.6179 | 13.68264 |
February | 672.00000 | 21.02181 | 34.82563 | -0.5010 | 11.43468 |
March | 744.00000 | 21.42103 | 40.36058 | -0.2962 | 7.72966 |
April | 720.00000 | 21.59960 | 49.19795 | -0.1576 | 6.49124 |
May | 744.00000 | 21.68708 | 55.33025 | -1.1581 | 34.61771 |
June | 720.00000 | 21.73947 | 54.77047 | -1.0823 | 31.31025 |
July | 744.00000 | 21.72840 | 57.78248 | -1.0476 | 29.78726 |
August | 744.00000 | 21.74024 | 57.58389 | -1.0377 | 29.37599 |
September | 720.00000 | 21.66528 | 58.20848 | -1.1356 | 33.63299 |
October | 744.00000 | 21.48607 | 52.99622 | -0.1853 | 6.67754 |
November | 720.00000 | 21.29946 | 41.87605 | -0.3493 | 8.36153 |
December | 744.00000 | 20.97432 | 36.50644 | -0.5142 | 11.15333 |
Annual Sum or Average | 8760.00000 | 21.43182 | 47.65792 | -0.6749 | 18.73370 |
Minimum of Months | 672.00000 | 20.79795 | 31.64771 | -1.1581 | 6.49124 |
Maximum of Months | 744.00000 | 21.74024 | 58.20848 | -0.1576 | 34.61771 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_6_FLR_3 PEOPLE
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 20.60793 | 31.94230 | -0.6912 | 15.84628 |
February | 672.00000 | 20.85413 | 35.10297 | -0.5661 | 12.84968 |
March | 744.00000 | 21.25477 | 40.89833 | -0.3560 | 8.32133 |
April | 720.00000 | 21.55188 | 49.42963 | -0.1822 | 6.57943 |
May | 744.00000 | 21.68079 | 55.58742 | -1.1668 | 34.95944 |
June | 720.00000 | 21.74033 | 54.82287 | -1.0831 | 31.32456 |
July | 744.00000 | 21.72824 | 57.90462 | -1.0500 | 29.86419 |
August | 744.00000 | 21.73841 | 58.08592 | -1.0481 | 29.75546 |
September | 720.00000 | 21.65502 | 58.95656 | -1.1580 | 34.52732 |
October | 744.00000 | 21.35253 | 53.89756 | -0.2398 | 6.96845 |
November | 720.00000 | 21.04280 | 42.60536 | -0.4372 | 9.62492 |
December | 744.00000 | 20.72239 | 37.01347 | -0.6012 | 13.27077 |
Annual Sum or Average | 8760.00000 | 21.32946 | 48.08913 | -0.7162 | 19.53436 |
Minimum of Months | 672.00000 | 20.60793 | 31.94230 | -1.1668 | 6.57943 |
Maximum of Months | 744.00000 | 21.74033 | 58.95656 | -0.1822 | 34.95944 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_1_FLR_6 PEOPLE
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 20.67283 | 32.18735 | -0.6911 | 15.85007 |
February | 672.00000 | 20.89641 | 35.43932 | -0.5661 | 13.13119 |
March | 744.00000 | 21.30220 | 41.00086 | -0.3305 | 8.45699 |
April | 720.00000 | 21.51724 | 50.01896 | -0.1699 | 6.82376 |
May | 744.00000 | 21.64679 | 56.16547 | -1.1505 | 34.44165 |
June | 720.00000 | 21.71170 | 55.00392 | -1.0658 | 30.75593 |
July | 744.00000 | 21.71567 | 58.24755 | -1.0239 | 28.93700 |
August | 744.00000 | 21.72978 | 57.65795 | -1.0093 | 28.34113 |
September | 720.00000 | 21.64338 | 58.96221 | -1.1240 | 33.26479 |
October | 744.00000 | 21.40520 | 54.07998 | -0.2067 | 7.06792 |
November | 720.00000 | 21.19995 | 42.58266 | -0.3930 | 9.35813 |
December | 744.00000 | 20.84122 | 37.20830 | -0.5822 | 12.97026 |
Annual Sum or Average | 8760.00000 | 21.35888 | 48.28029 | -0.6938 | 19.15553 |
Minimum of Months | 672.00000 | 20.67283 | 32.18735 | -1.1505 | 6.82376 |
Maximum of Months | 744.00000 | 21.72978 | 58.96221 | -0.1699 | 34.44165 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_2_FLR_6 PEOPLE
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 20.54897 | 32.41995 | -0.7522 | 17.78780 |
February | 672.00000 | 20.76278 | 35.69797 | -0.6265 | 14.55841 |
March | 744.00000 | 21.13795 | 41.51826 | -0.3920 | 9.27553 |
April | 720.00000 | 21.45823 | 50.35071 | -0.1970 | 6.97910 |
May | 744.00000 | 21.63790 | 56.44115 | -1.1600 | 34.81219 |
June | 720.00000 | 21.71363 | 55.03486 | -1.0663 | 30.74954 |
July | 744.00000 | 21.71657 | 58.34041 | -1.0260 | 28.99262 |
August | 744.00000 | 21.72678 | 58.06928 | -1.0208 | 28.73615 |
September | 720.00000 | 21.62334 | 59.83842 | -1.1496 | 34.26752 |
October | 744.00000 | 21.25095 | 55.05089 | -0.2675 | 7.51604 |
November | 720.00000 | 20.96693 | 43.26202 | -0.4793 | 10.78272 |
December | 744.00000 | 20.62410 | 37.67994 | -0.6636 | 15.13236 |
Annual Sum or Average | 8760.00000 | 21.26620 | 48.71025 | -0.7344 | 20.00229 |
Minimum of Months | 672.00000 | 20.54897 | 32.41995 | -1.1600 | 6.97910 |
Maximum of Months | 744.00000 | 21.72678 | 59.83842 | -0.1970 | 34.81219 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_3_MULT9_FLR_6 PEOPLE
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.12291 | 32.48866 | -0.5070 | 11.55790 |
February | 672.00000 | 21.22356 | 35.52504 | -0.4279 | 10.08611 |
March | 744.00000 | 21.47179 | 40.52698 | -0.2691 | 7.62644 |
April | 720.00000 | 21.57347 | 49.31690 | -0.1692 | 6.68884 |
May | 744.00000 | 21.64485 | 55.66785 | -1.1941 | 36.31307 |
June | 720.00000 | 21.70333 | 55.07334 | -1.1291 | 33.36533 |
July | 744.00000 | 21.70946 | 57.94927 | -1.0879 | 31.49201 |
August | 744.00000 | 21.72708 | 57.08181 | -1.0646 | 30.56036 |
September | 720.00000 | 21.65934 | 57.29250 | -1.1416 | 34.01934 |
October | 744.00000 | 21.54190 | 52.34532 | -0.1532 | 6.62605 |
November | 720.00000 | 21.48138 | 41.72684 | -0.2710 | 7.69675 |
December | 744.00000 | 21.27641 | 36.88652 | -0.4057 | 9.54647 |
Annual Sum or Average | 8760.00000 | 21.51263 | 47.72144 | -0.6533 | 18.85181 |
Minimum of Months | 672.00000 | 21.12291 | 32.48866 | -1.1941 | 6.62605 |
Maximum of Months | 744.00000 | 21.72708 | 57.94927 | -0.1532 | 36.31307 |
Report: OccupantComfortDataSummaryMonthly
For: BANQUET_FLR_6 PEOPLE
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.21733 | 29.92503 | -0.3458 | 7.96903 |
February | 672.00000 | 21.31789 | 32.99311 | -0.2756 | 7.25326 |
March | 744.00000 | 21.49280 | 40.20467 | -0.1438 | 6.02874 |
April | 720.00000 | 21.58854 | 50.12697 | -0.0339 | 5.57667 |
May | 744.00000 | 21.73250 | 59.15644 | -0.9669 | 25.41025 |
June | 720.00000 | 21.89699 | 59.62547 | -0.8717 | 21.81566 |
July | 744.00000 | 21.93670 | 62.57268 | -0.8282 | 20.19841 |
August | 744.00000 | 21.95070 | 62.60121 | -0.8236 | 20.06578 |
September | 720.00000 | 21.73358 | 62.53396 | -0.9479 | 24.66125 |
October | 744.00000 | 21.51711 | 53.17197 | -0.0499 | 5.52029 |
November | 720.00000 | 21.39835 | 40.68675 | -0.1836 | 6.27748 |
December | 744.00000 | 21.28866 | 34.69485 | -0.2767 | 7.10206 |
Annual Sum or Average | 8760.00000 | 21.59078 | 49.10996 | -0.4803 | 13.18947 |
Minimum of Months | 672.00000 | 21.21733 | 29.92503 | -0.9669 | 5.52029 |
Maximum of Months | 744.00000 | 21.95070 | 62.60121 | -0.0339 | 25.41025 |
Report: OccupantComfortDataSummaryMonthly
For: DINING_FLR_6 PEOPLE
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.25079 | 29.65267 | -0.3053 | 7.45051 |
February | 672.00000 | 21.35890 | 32.69727 | -0.2337 | 6.84945 |
March | 744.00000 | 21.54575 | 39.86962 | -0.0999 | 5.84379 |
April | 720.00000 | 21.65495 | 49.72564 | 0.01289 | 5.58515 |
May | 744.00000 | 21.81177 | 58.67790 | -0.8960 | 22.67056 |
June | 720.00000 | 21.98150 | 59.11900 | -0.8000 | 19.28158 |
July | 744.00000 | 22.01224 | 62.07393 | -0.7607 | 17.91207 |
August | 744.00000 | 22.02246 | 62.11197 | -0.7577 | 17.84767 |
September | 720.00000 | 21.80769 | 62.05172 | -0.8791 | 22.04316 |
October | 744.00000 | 21.57212 | 52.79457 | -0.0060 | 5.49634 |
November | 720.00000 | 21.44366 | 40.36832 | -0.1415 | 6.02887 |
December | 744.00000 | 21.32774 | 34.40212 | -0.2356 | 6.69859 |
Annual Sum or Average | 8760.00000 | 21.65072 | 48.71378 | -0.4265 | 12.00398 |
Minimum of Months | 672.00000 | 21.25079 | 29.65267 | -0.8960 | 5.49634 |
Maximum of Months | 744.00000 | 22.02246 | 62.11197 | 0.01289 | 22.67056 |
Report: OccupantComfortDataSummaryMonthly
For: KITCHEN_FLR_6 PEOPLE
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 22.48321 | 29.76861 | 0.57512 | 16.84921 |
February | 672.00000 | 22.62843 | 32.40271 | 0.66419 | 19.61590 |
March | 744.00000 | 22.85081 | 38.66881 | 0.82071 | 24.57005 |
April | 720.00000 | 22.95878 | 47.62625 | 0.94299 | 29.15514 |
May | 744.00000 | 23.06002 | 55.88854 | 0.41835 | 19.79515 |
June | 720.00000 | 23.13617 | 56.56216 | 0.49829 | 21.05300 |
July | 744.00000 | 23.14259 | 59.38285 | 0.53529 | 21.50717 |
August | 744.00000 | 23.15688 | 59.37602 | 0.54082 | 21.39202 |
September | 720.00000 | 23.06034 | 58.96679 | 0.43761 | 19.44660 |
October | 744.00000 | 22.89316 | 50.41313 | 0.92177 | 27.93235 |
November | 720.00000 | 22.76725 | 39.20934 | 0.77589 | 22.89310 |
December | 744.00000 | 22.61032 | 33.94225 | 0.66183 | 19.22676 |
Annual Sum or Average | 8760.00000 | 22.89693 | 46.92838 | 0.64913 | 21.95927 |
Minimum of Months | 672.00000 | 22.48321 | 29.76861 | 0.41835 | 16.84921 |
Maximum of Months | 744.00000 | 23.15688 | 59.38285 | 0.94299 | 29.15514 |
Report: OccupantComfortDataSummaryMonthly
For: STORAGE_FLR_1 PEOPLE
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 20.98903 | 25.91221 | -0.5439 | 11.36934 |
February | 672.00000 | 20.98700 | 29.27614 | -0.5080 | 10.65780 |
March | 744.00000 | 21.00036 | 36.97679 | -0.4319 | 9.10333 |
April | 720.00000 | 21.00023 | 47.54644 | -0.3569 | 7.84411 |
May | 744.00000 | 21.00601 | 57.77968 | -1.4698 | 49.27289 |
June | 720.00000 | 21.04414 | 59.32699 | -1.4250 | 46.87432 |
July | 744.00000 | 21.07981 | 63.09467 | -1.3856 | 44.76708 |
August | 744.00000 | 21.07918 | 63.44826 | -1.3820 | 44.57575 |
September | 720.00000 | 21.01095 | 61.84115 | -1.4383 | 47.59922 |
October | 744.00000 | 21.00052 | 50.77799 | -0.3423 | 7.55334 |
November | 720.00000 | 21.00012 | 37.35928 | -0.4376 | 9.20190 |
December | 744.00000 | 21.00014 | 30.91648 | -0.4955 | 10.32497 |
Annual Sum or Average | 8760.00000 | 21.01673 | 47.11791 | -0.8535 | 25.01362 |
Minimum of Months | 672.00000 | 20.98700 | 25.91221 | -1.4698 | 7.55334 |
Maximum of Months | 744.00000 | 21.07981 | 63.44826 | -0.3423 | 49.27289 |
Report: OccupantComfortDataSummaryMonthly
For: CORRIDOR_FLR_3 PEOPLE
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.00027 | 28.46302 | -0.5222 | 10.84190 |
February | 672.00000 | 21.00709 | 31.79907 | -0.4883 | 10.18831 |
March | 744.00000 | 21.03841 | 39.35639 | -0.4135 | 8.79092 |
April | 720.00000 | 21.12373 | 49.57110 | -0.3255 | 7.43960 |
May | 744.00000 | 21.28016 | 59.07835 | -1.3980 | 45.46464 |
June | 720.00000 | 21.73955 | 58.90739 | -1.2330 | 37.01338 |
July | 744.00000 | 21.92953 | 61.75494 | -1.1476 | 32.83697 |
August | 744.00000 | 22.00906 | 61.68719 | -1.1198 | 31.47860 |
September | 720.00000 | 21.53190 | 61.99108 | -1.2893 | 39.83379 |
October | 744.00000 | 21.09869 | 52.80678 | -0.3154 | 7.21451 |
November | 720.00000 | 21.00724 | 39.79695 | -0.4251 | 8.95543 |
December | 744.00000 | 21.00183 | 33.44845 | -0.4803 | 9.98396 |
Annual Sum or Average | 8760.00000 | 21.31608 | 48.30909 | -0.7648 | 20.89725 |
Minimum of Months | 672.00000 | 21.00027 | 28.46302 | -1.3980 | 7.21451 |
Maximum of Months | 744.00000 | 22.00906 | 61.99108 | -0.3154 | 45.46464 |
Report: OccupantComfortDataSummaryMonthly
For: CORRIDOR_FLR_6 PEOPLE
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 20.99227 | 26.72467 | -0.5556 | 11.67541 |
February | 672.00000 | 20.98854 | 30.04666 | -0.5095 | 10.74774 |
March | 744.00000 | 21.00463 | 37.68852 | -0.4136 | 8.82778 |
April | 720.00000 | 21.03357 | 48.11534 | -0.3229 | 7.43779 |
May | 744.00000 | 21.08167 | 57.89464 | -1.4003 | 45.60000 |
June | 720.00000 | 21.26468 | 58.50603 | -1.3051 | 40.68279 |
July | 744.00000 | 21.42121 | 61.41393 | -1.2258 | 36.72777 |
August | 744.00000 | 21.45359 | 61.45224 | -1.2108 | 35.94493 |
September | 720.00000 | 21.10412 | 61.53788 | -1.3669 | 43.86375 |
October | 744.00000 | 21.01608 | 51.22257 | -0.3198 | 7.29552 |
November | 720.00000 | 21.00068 | 38.06543 | -0.4301 | 9.10911 |
December | 744.00000 | 21.00028 | 31.69260 | -0.5010 | 10.46780 |
Annual Sum or Average | 8760.00000 | 21.11461 | 47.12003 | -0.7985 | 22.42865 |
Minimum of Months | 672.00000 | 20.98854 | 26.72467 | -1.4003 | 7.29552 |
Maximum of Months | 744.00000 | 21.45359 | 61.53788 | -0.3198 | 45.60000 |
Report: OccupantComfortDataSummaryMonthly
For: MECH_FLR_1 PEOPLE
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 20.99859 | 25.69902 | -0.5197 | 10.81792 |
February | 672.00000 | 20.99708 | 29.05637 | -0.4849 | 10.16182 |
March | 744.00000 | 21.00443 | 36.74128 | -0.4116 | 8.75175 |
April | 720.00000 | 21.01325 | 47.27314 | -0.3350 | 7.54002 |
May | 744.00000 | 21.04122 | 57.35947 | -1.4331 | 47.31708 |
June | 720.00000 | 21.11048 | 58.69666 | -1.3808 | 44.55828 |
July | 744.00000 | 21.15032 | 62.34053 | -1.3411 | 42.45755 |
August | 744.00000 | 21.15430 | 62.63106 | -1.3367 | 42.22778 |
September | 720.00000 | 21.04884 | 61.32692 | -1.4015 | 45.64821 |
October | 744.00000 | 21.00892 | 50.47757 | -0.3217 | 7.27355 |
November | 720.00000 | 21.00075 | 37.13368 | -0.4177 | 8.84568 |
December | 744.00000 | 21.00018 | 30.70517 | -0.4746 | 9.89889 |
Annual Sum or Average | 8760.00000 | 21.04442 | 46.71525 | -0.8236 | 23.87227 |
Minimum of Months | 672.00000 | 20.99708 | 25.69902 | -1.4331 | 7.27355 |
Maximum of Months | 744.00000 | 21.15430 | 62.63106 | -0.3217 | 47.31708 |
Report: ChillerReportMonthly
For: COOLSYS1 CHILLER1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportCHILLER ELECTRICITY ENERGY [J] | CHILLER ELECTRICITY RATE {Maximum} [W] | CHILLER ELECTRICITY RATE {TIMESTAMP} | CHILLER ELECTRICITY ENERGY {HOURS NON-ZERO} [HOURS] | CHILLER EVAPORATOR COOLING ENERGY [J] | CHILLER EVAPORATOR COOLING RATE [] | CHILLER CONDENSER HEAT TRANSFER ENERGY [J] | CHILLER COP [W/W] | CHILLER COP {Maximum} [W/W] | CHILLER COP {TIMESTAMP} | CHILLER PART LOAD RATIO [] | CHILLER PART LOAD RATIO [] | |
January | 0.116685E+11 | 99940.69 | 31-JAN-16:02 | 205.14 | 0.325220E+11 | 0.00 | 0.441905E+11 | 0.80 | 3.07 | 19-JAN-19:05 | 0.00 | 0.00 |
February | 0.346587E+11 | 142759.72 | 28-FEB-16:01 | 329.25 | 0.956658E+11 | 0.00 | 0.130325E+12 | 1.40 | 3.40 | 27-FEB-19:01 | 0.00 | 0.00 |
March | 0.925008E+11 | 173287.34 | 30-MAR-18:03 | 624.94 | 0.259421E+12 | 0.00 | 0.351922E+12 | 2.40 | 3.48 | 30-MAR-08:62 | 0.00 | 0.00 |
April | 0.164768E+12 | 177129.36 | 04-APR-15:03 | 685.75 | 0.480376E+12 | 0.00 | 0.645144E+12 | 2.75 | 3.90 | 22-APR-18:02 | 0.00 | 0.00 |
May | 0.287495E+12 | 228578.63 | 30-MAY-18:03 | 741.67 | 0.884586E+12 | 0.00 | 0.117208E+13 | 3.01 | 3.95 | 26-MAY-18:03 | 0.00 | 0.00 |
June | 0.401550E+12 | 273602.49 | 28-JUN-18:03 | 720.00 | 0.127560E+13 | 0.00 | 0.167715E+13 | 3.15 | 3.98 | 18-JUN-08:62 | 0.00 | 0.00 |
July | 0.491938E+12 | 308407.38 | 08-JUL-15:03 | 744.00 | 0.159997E+13 | 0.00 | 0.209190E+13 | 3.29 | 4.01 | 28-JUL-08:63 | 0.00 | 0.00 |
August | 0.510340E+12 | 295309.91 | 01-AUG-15:15 | 744.00 | 0.166840E+13 | 0.00 | 0.217874E+13 | 3.29 | 3.98 | 31-AUG-08:62 | 0.00 | 0.00 |
September | 0.342861E+12 | 264250.70 | 07-SEP-15:13 | 719.67 | 0.110512E+13 | 0.00 | 0.144798E+13 | 3.16 | 4.02 | 21-SEP-18:02 | 0.00 | 0.00 |
October | 0.160395E+12 | 223564.69 | 18-OCT-18:03 | 692.17 | 0.500134E+12 | 0.00 | 0.660529E+12 | 2.78 | 4.02 | 18-OCT-08:63 | 0.00 | 0.00 |
November | 0.734032E+11 | 172115.57 | 27-NOV-19:03 | 540.86 | 0.211508E+12 | 0.00 | 0.284911E+12 | 2.17 | 3.91 | 05-NOV-18:02 | 0.00 | 0.00 |
December | 0.217188E+11 | 128619.41 | 12-DEC-16:02 | 338.47 | 0.614312E+11 | 0.00 | 0.831500E+11 | 1.32 | 3.54 | 13-DEC-16:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.259330E+13 | 7085.92 | 0.817473E+13 | 0.00 | 0.107680E+14 | 2.46 | 0.00 | 0.00 | ||||
Minimum of Months | 0.116685E+11 | 99940.69 | 205.14 | 0.325220E+11 | 0.00 | 0.441905E+11 | 0.80 | 3.07 | 0.00 | 0.00 | ||
Maximum of Months | 0.510340E+12 | 308407.38 | 744.00 | 0.166840E+13 | 0.00 | 0.217874E+13 | 3.29 | 4.02 | 0.00 | 0.00 |
Report: BoilerReportMonthly
For: HEATSYS1 BOILER
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportBOILER HEATING ENERGY [J] | BOILER GAS CONSUMPTION [] | BOILER HEATING ENERGY {HOURS NON-ZERO} [HOURS] | BOILER HEATING RATE {Maximum} [W] | BOILER HEATING RATE {TIMESTAMP} | BOILER GAS CONSUMPTION RATE [] | BOILER INLET TEMPERATURE [C] | BOILER OUTLET TEMPERATURE [C] | BOILER MASS FLOW RATE [kg/s] | BOILER ANCILLARY ELECTRICITY RATE [W] | BOILER PART LOAD RATIO [] | BOILER PART LOAD RATIO {Maximum} [] | BOILER PART LOAD RATIO {TIMESTAMP} | |
January | 0.177946E+12 | 0.00 | 744.00 | 227651.54 | 07-JAN-16:06 | 0.00 | 37.99 | 60.00 | 0.74 | 0.00 | 0.13 | 0.45 | 07-JAN-16:06 |
February | 0.129319E+12 | 0.00 | 672.00 | 271426.31 | 12-FEB-07:10 | 0.00 | 36.18 | 60.00 | 0.57 | 0.00 | 0.11 | 0.54 | 12-FEB-07:10 |
March | 0.748495E+11 | 0.00 | 741.78 | 140801.43 | 23-MAR-08:62 | 0.00 | 33.89 | 59.92 | 0.27 | 0.00 | 0.06 | 0.28 | 23-MAR-08:62 |
April | 0.622143E+11 | 0.00 | 720.00 | 128622.50 | 06-APR-08:62 | 0.00 | 34.00 | 60.00 | 0.23 | 0.00 | 0.05 | 0.25 | 06-APR-08:62 |
May | 0.492884E+11 | 0.00 | 730.69 | 79482.28 | 10-MAY-08:04 | 0.00 | 32.83 | 59.50 | 0.17 | 0.00 | 0.04 | 0.16 | 10-MAY-08:04 |
June | 0.347510E+11 | 0.00 | 653.44 | 78651.59 | 08-JUN-11:13 | 0.00 | 31.77 | 57.32 | 0.12 | 0.00 | 0.03 | 0.16 | 08-JUN-11:13 |
July | 0.312085E+11 | 0.00 | 661.75 | 67592.25 | 03-JUL-10:35 | 0.00 | 31.28 | 56.70 | 0.10 | 0.00 | 0.02 | 0.13 | 03-JUL-10:35 |
August | 0.252592E+11 | 0.00 | 639.14 | 66693.96 | 08-AUG-10:35 | 0.00 | 31.17 | 55.72 | 0.08 | 0.00 | 0.02 | 0.13 | 08-AUG-10:35 |
September | 0.282334E+11 | 0.00 | 691.58 | 87426.83 | 30-SEP-15:05 | 0.00 | 29.55 | 58.82 | 0.09 | 0.00 | 0.02 | 0.17 | 30-SEP-15:05 |
October | 0.490641E+11 | 0.00 | 741.44 | 138521.36 | 26-OCT-08:62 | 0.00 | 31.32 | 59.89 | 0.17 | 0.00 | 0.04 | 0.27 | 26-OCT-08:62 |
November | 0.708638E+11 | 0.00 | 720.00 | 151334.36 | 21-NOV-09:02 | 0.00 | 33.75 | 60.00 | 0.28 | 0.00 | 0.05 | 0.30 | 21-NOV-09:02 |
December | 0.115266E+12 | 0.00 | 744.00 | 175527.61 | 18-DEC-09:02 | 0.00 | 36.96 | 60.00 | 0.47 | 0.00 | 0.08 | 0.35 | 18-DEC-09:02 |
Annual Sum or Average | 0.848264E+12 | 0.00 | 8459.83 | 0.00 | 33.38 | 58.98 | 0.27 | 0.00 | 0.05 | ||||
Minimum of Months | 0.252592E+11 | 0.00 | 639.14 | 66693.96 | 0.00 | 29.55 | 55.72 | 0.08 | 0.00 | 0.02 | 0.13 | ||
Maximum of Months | 0.177946E+12 | 0.00 | 744.00 | 271426.31 | 0.00 | 37.99 | 60.00 | 0.74 | 0.00 | 0.13 | 0.54 |
Report: DXReportMonthly
For: VAV WITH REHEAT COOLING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRICITY RATE [] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.206885E+11 | 0.00 | 58.72 | 0.162733E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 243323.81 | 19-JAN-19:05 | 192759.27 | 31-JAN-15:00 | 0.00 | 0.00 | 0.00 |
February | 0.619588E+11 | 0.00 | 180.50 | 0.592234E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 268537.31 | 28-FEB-17:10 | 268537.31 | 28-FEB-17:10 | 0.00 | 0.00 | 0.00 |
March | 0.172776E+12 | 0.00 | 367.11 | 0.162748E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 349050.94 | 30-MAR-10:40 | 310464.89 | 11-MAR-19:01 | 0.00 | 0.00 | 0.00 |
April | 0.337422E+12 | 0.00 | 544.28 | 0.284413E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 448744.67 | 22-APR-17:17 | 342561.27 | 19-APR-15:55 | 0.00 | 0.00 | 0.00 |
May | 0.654340E+12 | 0.00 | 699.67 | 0.457116E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 584775.79 | 30-MAY-22:00 | 379665.71 | 15-MAY-18:54 | 0.00 | 0.00 | 0.00 |
June | 0.958015E+12 | 0.00 | 708.00 | 0.609792E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 651558.35 | 17-JUN-21:00 | 358509.93 | 06-JUN-17:12 | 0.00 | 0.00 | 0.00 |
July | 0.122052E+13 | 0.00 | 744.00 | 0.683322E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 689391.02 | 29-JUL-19:20 | 380969.56 | 08-JUL-16:00 | 0.00 | 0.00 | 0.00 |
August | 0.127288E+13 | 0.00 | 744.00 | 0.705390E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 656645.02 | 20-AUG-10:35 | 373350.19 | 01-AUG-17:12 | 0.00 | 0.00 | 0.00 |
September | 0.831474E+12 | 0.00 | 707.83 | 0.523115E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 630496.78 | 09-SEP-10:35 | 338987.00 | 09-SEP-10:50 | 0.00 | 0.00 | 0.00 |
October | 0.358318E+12 | 0.00 | 455.47 | 0.240977E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 634587.27 | 19-OCT-04:20 | 341997.06 | 11-OCT-17:10 | 0.00 | 0.00 | 0.00 |
November | 0.142871E+12 | 0.00 | 300.27 | 0.113170E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 420629.27 | 27-NOV-19:05 | 240345.05 | 02-NOV-15:30 | 0.00 | 0.00 | 0.00 |
December | 0.351406E+11 | 0.00 | 103.15 | 0.285739E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 361394.06 | 13-DEC-11:40 | 238092.67 | 12-DEC-14:50 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.606640E+13 | 0.00 | 5613.01 | 0.388411E+13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.206885E+11 | 0.00 | 58.72 | 0.162733E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 243323.81 | 192759.27 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.127288E+13 | 0.00 | 744.00 | 0.705390E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 689391.02 | 380969.56 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: FLR_3_DOAS COOLING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRICITY RATE [] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.176252E+10 | 0.00 | 46.33 | 0.137197E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23359.34 | 19-JAN-16:00 | 22285.22 | 31-JAN-15:00 | 0.00 | 0.00 | 0.00 |
February | 0.553442E+10 | 0.00 | 130.67 | 0.547982E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27771.79 | 28-FEB-15:00 | 27771.79 | 28-FEB-15:00 | 0.00 | 0.00 | 0.00 |
March | 0.173955E+11 | 0.00 | 332.33 | 0.157534E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 42240.28 | 31-MAR-11:00 | 30236.64 | 30-MAR-15:02 | 0.00 | 0.00 | 0.00 |
April | 0.355080E+11 | 0.00 | 498.33 | 0.290149E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 52592.95 | 04-APR-10:50 | 30871.28 | 16-APR-14:00 | 0.00 | 0.00 | 0.00 |
May | 0.702642E+11 | 0.00 | 686.67 | 0.481776E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 61735.65 | 23-MAY-14:00 | 32427.07 | 30-MAY-15:00 | 0.00 | 0.00 | 0.00 |
June | 0.102458E+12 | 0.00 | 702.83 | 0.650665E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 71662.73 | 26-JUN-18:00 | 34790.96 | 06-JUN-15:00 | 0.00 | 0.00 | 0.00 |
July | 0.129170E+12 | 0.00 | 744.00 | 0.725090E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 79586.62 | 26-JUL-07:25 | 36308.38 | 08-JUL-15:02 | 0.00 | 0.00 | 0.00 |
August | 0.131783E+12 | 0.00 | 744.00 | 0.752888E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 78977.54 | 05-AUG-07:40 | 35277.75 | 01-AUG-15:00 | 0.00 | 0.00 | 0.00 |
September | 0.921407E+11 | 0.00 | 699.00 | 0.567250E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 69655.32 | 28-SEP-12:10 | 33217.38 | 07-SEP-15:02 | 0.00 | 0.00 | 0.00 |
October | 0.382673E+11 | 0.00 | 416.33 | 0.249070E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 74182.51 | 19-OCT-02:30 | 31118.34 | 10-OCT-14:00 | 0.00 | 0.00 | 0.00 |
November | 0.148105E+11 | 0.00 | 246.17 | 0.110295E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 46083.91 | 19-NOV-23:57 | 27568.65 | 05-NOV-15:02 | 0.00 | 0.00 | 0.00 |
December | 0.325640E+10 | 0.00 | 74.17 | 0.254138E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 35337.19 | 13-DEC-13:00 | 26036.50 | 12-DEC-14:50 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.642351E+12 | 0.00 | 5320.83 | 0.407865E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.176252E+10 | 0.00 | 46.33 | 0.137197E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23359.34 | 22285.22 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.131783E+12 | 0.00 | 744.00 | 0.752888E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 79586.62 | 36308.38 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: ROOM_1_FLR_3 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRICITY RATE [] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 97789098.46 | 0.00 | 31.49 | 77786337.49 | 0.00 | 0.00 | 0.00 | 0.00 | 15495.26 | 29-JAN-16:01 | 15495.26 | 29-JAN-16:01 | 0.00 | 0.00 | 0.00 |
February | 0.622339E+09 | 0.00 | 108.97 | 0.588356E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 15523.30 | 28-FEB-16:01 | 15523.30 | 28-FEB-16:01 | 0.00 | 0.00 | 0.00 |
March | 0.240639E+10 | 0.00 | 318.13 | 0.167756E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16364.75 | 28-MAR-15:02 | 15516.65 | 05-MAR-16:01 | 0.00 | 0.00 | 0.00 |
April | 0.428488E+10 | 0.00 | 483.63 | 0.258463E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17601.92 | 04-APR-15:01 | 15523.77 | 25-APR-15:01 | 0.00 | 0.00 | 0.00 |
May | 0.695304E+10 | 0.00 | 631.29 | 0.378562E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18139.18 | 28-MAY-08:62 | 15525.29 | 09-MAY-15:01 | 0.00 | 0.00 | 0.00 |
June | 0.102841E+11 | 0.00 | 662.19 | 0.597279E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20148.28 | 29-JUN-08:62 | 15524.95 | 10-JUN-15:01 | 0.00 | 0.00 | 0.00 |
July | 0.121877E+11 | 0.00 | 686.82 | 0.706203E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20066.31 | 30-JUL-08:62 | 15004.88 | 17-JUL-18:02 | 0.00 | 0.00 | 0.00 |
August | 0.130542E+11 | 0.00 | 697.62 | 0.757532E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19913.94 | 29-AUG-08:62 | 15005.91 | 06-AUG-18:02 | 0.00 | 0.00 | 0.00 |
September | 0.795416E+10 | 0.00 | 620.19 | 0.418922E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19885.77 | 17-SEP-08:62 | 15018.65 | 08-SEP-15:02 | 0.00 | 0.00 | 0.00 |
October | 0.351496E+10 | 0.00 | 406.54 | 0.192629E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19449.67 | 18-OCT-15:02 | 15525.01 | 12-OCT-15:01 | 0.00 | 0.00 | 0.00 |
November | 0.115743E+10 | 0.00 | 218.76 | 0.777775E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 17019.11 | 19-NOV-16:02 | 15520.19 | 11-NOV-16:01 | 0.00 | 0.00 | 0.00 |
December | 0.269327E+09 | 0.00 | 65.67 | 0.170363E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 15643.11 | 12-DEC-16:02 | 15504.92 | 10-DEC-16:02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.627863E+11 | 0.00 | 4931.32 | 0.363877E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 97789098.46 | 0.00 | 31.49 | 77786337.49 | 0.00 | 0.00 | 0.00 | 0.00 | 15495.26 | 15004.88 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.130542E+11 | 0.00 | 697.62 | 0.757532E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20148.28 | 15525.29 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: ROOM_2_FLR_3 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRICITY RATE [] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 9780428.22 | 0.00 | 8.95 | 5270602.69 | 0.00 | 0.00 | 0.00 | 0.00 | 6920.84 | 29-JAN-16:01 | 6920.84 | 29-JAN-16:01 | 0.00 | 0.00 | 0.00 |
February | 0.303224E+09 | 0.00 | 63.08 | 0.284464E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 15353.49 | 28-FEB-16:01 | 15353.49 | 28-FEB-16:01 | 0.00 | 0.00 | 0.00 |
March | 0.163807E+10 | 0.00 | 252.84 | 0.105900E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16091.12 | 29-MAR-15:02 | 15345.94 | 05-MAR-16:01 | 0.00 | 0.00 | 0.00 |
April | 0.362209E+10 | 0.00 | 444.94 | 0.210328E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17342.47 | 04-APR-15:01 | 15353.69 | 25-APR-15:01 | 0.00 | 0.00 | 0.00 |
May | 0.662543E+10 | 0.00 | 613.56 | 0.357559E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17979.56 | 28-MAY-08:62 | 15355.57 | 09-MAY-15:01 | 0.00 | 0.00 | 0.00 |
June | 0.102198E+11 | 0.00 | 661.39 | 0.597450E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19889.45 | 29-JUN-08:62 | 15355.12 | 10-JUN-15:01 | 0.00 | 0.00 | 0.00 |
July | 0.120336E+11 | 0.00 | 687.49 | 0.698804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19943.78 | 27-JUL-08:62 | 14846.60 | 21-JUL-15:02 | 0.00 | 0.00 | 0.00 |
August | 0.124146E+11 | 0.00 | 695.74 | 0.707718E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19540.75 | 24-AUG-08:62 | 14825.71 | 26-AUG-15:02 | 0.00 | 0.00 | 0.00 |
September | 0.694042E+10 | 0.00 | 594.29 | 0.348380E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19674.06 | 17-SEP-08:62 | 14831.14 | 22-SEP-18:02 | 0.00 | 0.00 | 0.00 |
October | 0.236365E+10 | 0.00 | 307.52 | 0.118797E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19253.80 | 18-OCT-15:02 | 15354.41 | 12-OCT-15:01 | 0.00 | 0.00 | 0.00 |
November | 0.520211E+09 | 0.00 | 122.96 | 0.281858E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16983.55 | 05-NOV-15:02 | 15349.92 | 11-NOV-16:01 | 0.00 | 0.00 | 0.00 |
December | 62905346.47 | 0.00 | 24.87 | 26365744.93 | 0.00 | 0.00 | 0.00 | 0.00 | 14631.42 | 11-DEC-16:02 | 13729.19 | 10-DEC-16:02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.567537E+11 | 0.00 | 4477.63 | 0.320473E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 9780428.22 | 0.00 | 8.95 | 5270602.69 | 0.00 | 0.00 | 0.00 | 0.00 | 6920.84 | 6920.84 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.124146E+11 | 0.00 | 695.74 | 0.707718E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19943.78 | 15355.57 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRICITY RATE [] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.128980E+10 | 0.00 | 43.08 | 0.118804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25679.39 | 29-JAN-13:30 | 25679.39 | 29-JAN-13:30 | 0.00 | 0.00 | 0.00 |
February | 0.638017E+10 | 0.00 | 131.58 | 0.625963E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 33285.24 | 26-FEB-14:50 | 33285.24 | 26-FEB-14:50 | 0.00 | 0.00 | 0.00 |
March | 0.148582E+11 | 0.00 | 347.36 | 0.107911E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 35379.51 | 30-MAR-13:30 | 28431.86 | 13-MAR-16:10 | 0.00 | 0.00 | 0.00 |
April | 0.200416E+11 | 0.00 | 456.17 | 0.108434E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 30831.91 | 15-APR-14:00 | 26336.15 | 15-APR-14:00 | 0.00 | 0.00 | 0.00 |
May | 0.278309E+11 | 0.00 | 558.24 | 0.122362E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 31892.42 | 06-MAY-20:40 | 20254.97 | 19-MAY-19:10 | 0.00 | 0.00 | 0.00 |
June | 0.432443E+11 | 0.00 | 677.63 | 0.213762E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 37608.17 | 25-JUN-19:05 | 27278.05 | 24-JUN-19:10 | 0.00 | 0.00 | 0.00 |
July | 0.530759E+11 | 0.00 | 719.42 | 0.265478E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 46223.93 | 13-JUL-21:00 | 33004.63 | 08-JUL-19:10 | 0.00 | 0.00 | 0.00 |
August | 0.625542E+11 | 0.00 | 744.00 | 0.338721E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 43674.06 | 23-AUG-21:00 | 35172.29 | 19-AUG-13:50 | 0.00 | 0.00 | 0.00 |
September | 0.426910E+11 | 0.00 | 621.72 | 0.226067E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 49014.08 | 24-SEP-14:40 | 39728.35 | 24-SEP-12:10 | 0.00 | 0.00 | 0.00 |
October | 0.277047E+11 | 0.00 | 460.54 | 0.177794E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 49469.81 | 11-OCT-15:13 | 39555.40 | 09-OCT-14:50 | 0.00 | 0.00 | 0.00 |
November | 0.149007E+11 | 0.00 | 331.56 | 0.123791E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 36836.16 | 12-NOV-14:00 | 36836.16 | 12-NOV-14:00 | 0.00 | 0.00 | 0.00 |
December | 0.630885E+10 | 0.00 | 158.00 | 0.533903E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36362.85 | 12-DEC-12:30 | 35758.22 | 10-DEC-14:10 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.320880E+12 | 0.00 | 5249.31 | 0.181219E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.128980E+10 | 0.00 | 43.08 | 0.118804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25679.39 | 20254.97 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.625542E+11 | 0.00 | 744.00 | 0.338721E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 49469.81 | 39728.35 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRICITY RATE [] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.240197E+10 | 0.00 | 89.15 | 0.119051E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 92038.06 | 01-JAN-09:02 | 90469.58 | 01-JAN-09:02 | 0.00 | 0.00 | 0.00 |
February | 0.846346E+10 | 0.00 | 211.38 | 0.601487E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 109240.69 | 18-FEB-09:02 | 96716.78 | 28-FEB-19:02 | 0.00 | 0.00 | 0.00 |
March | 0.222262E+11 | 0.00 | 440.24 | 0.149447E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 103106.70 | 30-MAR-08:62 | 97267.05 | 30-MAR-18:02 | 0.00 | 0.00 | 0.00 |
April | 0.395920E+11 | 0.00 | 483.94 | 0.244904E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 116020.51 | 23-APR-08:62 | 96877.93 | 09-APR-18:01 | 0.00 | 0.00 | 0.00 |
May | 0.622112E+11 | 0.00 | 541.62 | 0.375605E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 119436.17 | 27-MAY-08:62 | 98264.95 | 09-MAY-15:01 | 0.00 | 0.00 | 0.00 |
June | 0.808349E+11 | 0.00 | 586.99 | 0.535260E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 133042.49 | 29-JUN-08:62 | 102028.34 | 10-JUN-15:01 | 0.00 | 0.00 | 0.00 |
July | 0.922895E+11 | 0.00 | 622.12 | 0.597048E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 133356.78 | 27-JUL-08:62 | 96403.29 | 16-JUL-18:02 | 0.00 | 0.00 | 0.00 |
August | 0.920284E+11 | 0.00 | 614.99 | 0.592760E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 129986.61 | 12-AUG-08:62 | 96610.02 | 25-AUG-18:02 | 0.00 | 0.00 | 0.00 |
September | 0.629723E+11 | 0.00 | 522.65 | 0.363969E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 130171.23 | 17-SEP-08:62 | 97607.12 | 15-SEP-18:02 | 0.00 | 0.00 | 0.00 |
October | 0.319075E+11 | 0.00 | 494.72 | 0.167098E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 121326.85 | 18-OCT-08:63 | 95170.10 | 02-OCT-18:02 | 0.00 | 0.00 | 0.00 |
November | 0.151899E+11 | 0.00 | 340.46 | 0.906893E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 112475.42 | 27-NOV-19:03 | 95526.34 | 06-NOV-19:02 | 0.00 | 0.00 | 0.00 |
December | 0.512686E+10 | 0.00 | 172.48 | 0.268561E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 105872.78 | 24-DEC-09:02 | 85812.15 | 12-DEC-19:02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.515244E+12 | 0.00 | 5120.74 | 0.321569E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.240197E+10 | 0.00 | 89.15 | 0.119051E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 92038.06 | 85812.15 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.922895E+11 | 0.00 | 622.12 | 0.597048E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 133356.78 | 102028.34 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: ROOM_5_FLR_3 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRICITY RATE [] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 65521443.26 | 0.00 | 26.35 | 45265117.51 | 0.00 | 0.00 | 0.00 | 0.00 | 13342.75 | 29-JAN-16:01 | 13342.75 | 29-JAN-16:01 | 0.00 | 0.00 | 0.00 |
February | 0.653139E+09 | 0.00 | 118.36 | 0.619602E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 14028.52 | 28-FEB-16:01 | 14028.52 | 28-FEB-16:01 | 0.00 | 0.00 | 0.00 |
March | 0.204949E+10 | 0.00 | 333.42 | 0.136841E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15631.51 | 30-MAR-08:62 | 14021.40 | 12-MAR-15:01 | 0.00 | 0.00 | 0.00 |
April | 0.412262E+10 | 0.00 | 496.13 | 0.244400E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15913.35 | 04-APR-15:01 | 14028.25 | 10-APR-15:02 | 0.00 | 0.00 | 0.00 |
May | 0.717207E+10 | 0.00 | 660.37 | 0.397242E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16728.35 | 28-MAY-08:62 | 14030.24 | 09-MAY-15:01 | 0.00 | 0.00 | 0.00 |
June | 0.105195E+11 | 0.00 | 688.64 | 0.611293E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17820.28 | 23-JUN-08:62 | 14029.87 | 10-JUN-15:01 | 0.00 | 0.00 | 0.00 |
July | 0.126154E+11 | 0.00 | 705.25 | 0.742981E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18146.43 | 30-JUL-08:62 | 13575.41 | 10-JUL-15:02 | 0.00 | 0.00 | 0.00 |
August | 0.131668E+11 | 0.00 | 713.27 | 0.774251E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17873.18 | 24-AUG-08:62 | 13547.67 | 01-AUG-15:02 | 0.00 | 0.00 | 0.00 |
September | 0.803586E+10 | 0.00 | 635.68 | 0.432799E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18008.55 | 17-SEP-08:62 | 13574.65 | 22-SEP-18:02 | 0.00 | 0.00 | 0.00 |
October | 0.343659E+10 | 0.00 | 429.49 | 0.185066E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17595.29 | 18-OCT-15:02 | 14029.79 | 12-OCT-15:01 | 0.00 | 0.00 | 0.00 |
November | 0.102312E+10 | 0.00 | 215.24 | 0.661525E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 15549.53 | 05-NOV-15:02 | 14025.53 | 11-NOV-16:01 | 0.00 | 0.00 | 0.00 |
December | 0.228530E+09 | 0.00 | 63.27 | 0.130656E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 14043.46 | 12-DEC-16:02 | 13670.10 | 10-DEC-16:02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.630887E+11 | 0.00 | 5085.47 | 0.367058E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 65521443.26 | 0.00 | 26.35 | 45265117.51 | 0.00 | 0.00 | 0.00 | 0.00 | 13342.75 | 13342.75 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.131668E+11 | 0.00 | 713.27 | 0.774251E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18146.43 | 14030.24 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: ROOM_6_FLR_3 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRICITY RATE [] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 8742117.33 | 0.00 | 7.60 | 4419040.87 | 0.00 | 0.00 | 0.00 | 0.00 | 3302.85 | 19-JAN-19:05 | 3106.40 | 29-JAN-19:03 | 0.00 | 0.00 | 0.00 |
February | 0.308724E+09 | 0.00 | 68.04 | 0.287324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 13604.81 | 28-FEB-16:01 | 13604.81 | 28-FEB-16:01 | 0.00 | 0.00 | 0.00 |
March | 0.126449E+10 | 0.00 | 249.34 | 0.741502E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 15467.03 | 30-MAR-08:62 | 13431.56 | 27-MAR-15:02 | 0.00 | 0.00 | 0.00 |
April | 0.342224E+10 | 0.00 | 459.81 | 0.194679E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15688.89 | 04-APR-15:01 | 13903.68 | 10-APR-15:02 | 0.00 | 0.00 | 0.00 |
May | 0.682164E+10 | 0.00 | 650.41 | 0.375638E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16610.39 | 28-MAY-08:62 | 13905.40 | 09-MAY-15:01 | 0.00 | 0.00 | 0.00 |
June | 0.104511E+11 | 0.00 | 689.40 | 0.609336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17669.17 | 23-JUN-08:62 | 13905.20 | 10-JUN-15:01 | 0.00 | 0.00 | 0.00 |
July | 0.124554E+11 | 0.00 | 705.45 | 0.732513E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18082.00 | 27-JUL-08:62 | 13322.38 | 08-JUL-15:02 | 0.00 | 0.00 | 0.00 |
August | 0.125208E+11 | 0.00 | 711.05 | 0.716435E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17717.44 | 24-AUG-08:62 | 13363.03 | 25-AUG-15:02 | 0.00 | 0.00 | 0.00 |
September | 0.698959E+10 | 0.00 | 626.03 | 0.358016E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17853.70 | 17-SEP-08:62 | 13254.94 | 22-SEP-18:02 | 0.00 | 0.00 | 0.00 |
October | 0.224464E+10 | 0.00 | 312.59 | 0.104889E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17457.19 | 18-OCT-15:02 | 13372.87 | 12-OCT-15:01 | 0.00 | 0.00 | 0.00 |
November | 0.387255E+09 | 0.00 | 122.03 | 0.168945E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 14947.38 | 05-NOV-15:02 | 12580.32 | 06-NOV-16:01 | 0.00 | 0.00 | 0.00 |
December | 45555057.22 | 0.00 | 20.55 | 13965452.53 | 0.00 | 0.00 | 0.00 | 0.00 | 8510.34 | 12-DEC-16:02 | 5585.48 | 12-DEC-16:02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.569201E+11 | 0.00 | 4622.30 | 0.321312E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 8742117.33 | 0.00 | 7.60 | 4419040.87 | 0.00 | 0.00 | 0.00 | 0.00 | 3302.85 | 3106.40 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.125208E+11 | 0.00 | 711.05 | 0.732513E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18082.00 | 13905.40 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: ROOM_1_FLR_6 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRICITY RATE [] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 14536349.02 | 0.00 | 17.06 | 12542332.32 | 0.00 | 0.00 | 0.00 | 0.00 | 4149.95 | 29-JAN-16:01 | 4149.95 | 29-JAN-16:01 | 0.00 | 0.00 | 0.00 |
February | 0.150841E+09 | 0.00 | 88.88 | 0.145204E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4157.44 | 28-FEB-16:01 | 4157.44 | 28-FEB-16:01 | 0.00 | 0.00 | 0.00 |
March | 0.625971E+09 | 0.00 | 295.96 | 0.442583E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4426.84 | 28-MAR-15:02 | 4155.70 | 05-MAR-16:01 | 0.00 | 0.00 | 0.00 |
April | 0.119798E+10 | 0.00 | 468.93 | 0.752553E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4790.97 | 21-APR-18:02 | 4157.61 | 25-APR-15:01 | 0.00 | 0.00 | 0.00 |
May | 0.200542E+10 | 0.00 | 636.16 | 0.114615E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5012.17 | 28-MAY-08:62 | 4158.10 | 09-MAY-15:01 | 0.00 | 0.00 | 0.00 |
June | 0.292635E+10 | 0.00 | 667.34 | 0.175902E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5541.07 | 29-JUN-08:62 | 4157.90 | 10-JUN-15:01 | 0.00 | 0.00 | 0.00 |
July | 0.346147E+10 | 0.00 | 691.69 | 0.208290E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5580.43 | 30-JUL-08:62 | 4013.43 | 05-JUL-18:02 | 0.00 | 0.00 | 0.00 |
August | 0.367818E+10 | 0.00 | 701.67 | 0.220686E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5507.59 | 29-AUG-08:62 | 4023.88 | 17-AUG-18:02 | 0.00 | 0.00 | 0.00 |
September | 0.219933E+10 | 0.00 | 619.10 | 0.119701E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5518.84 | 17-SEP-08:62 | 3976.12 | 26-SEP-15:02 | 0.00 | 0.00 | 0.00 |
October | 0.942790E+09 | 0.00 | 377.72 | 0.537660E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5045.94 | 18-OCT-15:02 | 4157.88 | 12-OCT-15:01 | 0.00 | 0.00 | 0.00 |
November | 0.276966E+09 | 0.00 | 180.19 | 0.187680E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4576.36 | 19-NOV-16:02 | 4156.82 | 11-NOV-16:01 | 0.00 | 0.00 | 0.00 |
December | 55259574.57 | 0.00 | 48.12 | 34590674.93 | 0.00 | 0.00 | 0.00 | 0.00 | 4229.96 | 12-DEC-16:02 | 4152.54 | 10-DEC-16:02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.175351E+11 | 0.00 | 4792.82 | 0.105047E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 14536349.02 | 0.00 | 17.06 | 12542332.32 | 0.00 | 0.00 | 0.00 | 0.00 | 4149.95 | 3976.12 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.367818E+10 | 0.00 | 701.67 | 0.220686E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5580.43 | 4158.10 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: ROOM_2_FLR_6 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRICITY RATE [] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 1294287.95 | 0.00 | 1.19 | 826905.34 | 0.00 | 0.00 | 0.00 | 0.00 | 1029.96 | 19-JAN-19:05 | 757.32 | 28-JAN-16:03 | 0.00 | 0.00 | 0.00 |
February | 73614742.03 | 0.00 | 49.17 | 70779331.11 | 0.00 | 0.00 | 0.00 | 0.00 | 4107.19 | 28-FEB-16:01 | 4107.19 | 28-FEB-16:01 | 0.00 | 0.00 | 0.00 |
March | 0.422228E+09 | 0.00 | 227.52 | 0.277823E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4333.50 | 28-MAR-15:02 | 4105.18 | 05-MAR-16:01 | 0.00 | 0.00 | 0.00 |
April | 0.101651E+10 | 0.00 | 433.75 | 0.615137E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4696.45 | 21-APR-18:02 | 4107.27 | 25-APR-15:01 | 0.00 | 0.00 | 0.00 |
May | 0.191440E+10 | 0.00 | 624.83 | 0.108524E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4959.51 | 28-MAY-08:62 | 4107.69 | 09-MAY-15:01 | 0.00 | 0.00 | 0.00 |
June | 0.290886E+10 | 0.00 | 667.02 | 0.175270E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5459.38 | 29-JUN-08:62 | 4107.58 | 10-JUN-15:01 | 0.00 | 0.00 | 0.00 |
July | 0.342114E+10 | 0.00 | 692.06 | 0.205501E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5513.01 | 30-JUL-08:62 | 3958.73 | 15-JUL-18:02 | 0.00 | 0.00 | 0.00 |
August | 0.351241E+10 | 0.00 | 699.35 | 0.206710E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5398.23 | 12-AUG-08:62 | 3973.50 | 06-AUG-15:02 | 0.00 | 0.00 | 0.00 |
September | 0.192717E+10 | 0.00 | 599.32 | 0.997378E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5454.84 | 17-SEP-08:62 | 3973.06 | 15-SEP-18:02 | 0.00 | 0.00 | 0.00 |
October | 0.638050E+09 | 0.00 | 282.68 | 0.335269E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5055.16 | 18-OCT-15:02 | 4107.43 | 12-OCT-15:01 | 0.00 | 0.00 | 0.00 |
November | 0.120891E+09 | 0.00 | 95.27 | 65494273.12 | 0.00 | 0.00 | 0.00 | 0.00 | 4533.81 | 05-NOV-15:02 | 4106.23 | 11-NOV-16:01 | 0.00 | 0.00 | 0.00 |
December | 11230854.36 | 0.00 | 15.35 | 4415731.28 | 0.00 | 0.00 | 0.00 | 0.00 | 3701.85 | 11-DEC-16:02 | 3310.33 | 11-DEC-16:02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.159678E+11 | 0.00 | 4387.52 | 0.932717E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 1294287.95 | 0.00 | 1.19 | 826905.34 | 0.00 | 0.00 | 0.00 | 0.00 | 1029.96 | 757.32 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.351241E+10 | 0.00 | 699.35 | 0.206710E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5513.01 | 4107.69 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRICITY RATE [] | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.968966E+09 | 0.00 | 120.77 | 0.879110E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 19149.15 | 13-JAN-16:01 | 19149.15 | 13-JAN-16:01 | 0.00 | 0.00 | 0.00 |
February | 0.207855E+10 | 0.00 | 199.89 | 0.193331E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19171.21 | 28-FEB-16:01 | 19171.21 | 28-FEB-16:01 | 0.00 | 0.00 | 0.00 |
March | 0.507141E+10 | 0.00 | 434.65 | 0.373886E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20377.74 | 28-MAR-15:02 | 19169.68 | 24-MAR-15:01 | 0.00 | 0.00 | 0.00 |
April | 0.701954E+10 | 0.00 | 527.50 | 0.437275E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22261.22 | 21-APR-18:02 | 19171.30 | 25-APR-15:01 | 0.00 | 0.00 | 0.00 |
May | 0.102714E+11 | 0.00 | 643.16 | 0.569242E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22656.29 | 27-MAY-08:62 | 19171.31 | 10-MAY-15:01 | 0.00 | 0.00 | 0.00 |
June | 0.141344E+11 | 0.00 | 661.60 | 0.837962E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 26015.38 | 29-JUN-08:62 | 19170.42 | 10-JUN-18:02 | 0.00 | 0.00 | 0.00 |
July | 0.170350E+11 | 0.00 | 685.78 | 0.102382E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 25790.42 | 30-JUL-08:62 | 18539.35 | 15-JUL-15:02 | 0.00 | 0.00 | 0.00 |
August | 0.189524E+11 | 0.00 | 696.84 | 0.119019E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 25502.53 | 29-AUG-08:62 | 18426.15 | 06-AUG-15:02 | 0.00 | 0.00 | 0.00 |
September | 0.131787E+11 | 0.00 | 635.75 | 0.778169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25430.90 | 17-SEP-08:62 | 18216.53 | 15-SEP-18:02 | 0.00 | 0.00 | 0.00 |
October | 0.808785E+10 | 0.00 | 523.94 | 0.514068E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22918.23 | 01-OCT-18:01 | 19169.26 | 13-OCT-15:02 | 0.00 | 0.00 | 0.00 |
November | 0.448536E+10 | 0.00 | 388.18 | 0.341044E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21702.13 | 27-NOV-19:03 | 19167.56 | 11-NOV-16:01 | 0.00 | 0.00 | 0.00 |
December | 0.213300E+10 | 0.00 | 216.94 | 0.175897E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21111.45 | 13-DEC-16:03 | 19161.33 | 26-DEC-16:02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.103416E+12 | 0.00 | 5735.01 | 0.652280E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.968966E+09 | 0.00 | 120.77 | 0.879110E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 19149.15 | 18216.53 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.189524E+11 | 0.00 | 696.84 | 0.119019E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 26015.38 | 19171.31 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: RETAIL_1_FLR_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 527.26 | 366.27 | 160.99 | 603.20 | 598.69 | 0.00 | 0.00 | 0.00 |
February | 491.15 | 327.66 | 163.48 | 617.12 | 491.74 | 0.00 | 0.00 | 0.00 |
March | 449.12 | 235.68 | 213.44 | 640.33 | 301.24 | 0.00 | 0.00 | 0.00 |
April | 338.00 | 112.77 | 225.23 | 553.71 | 228.07 | 0.00 | 0.00 | 0.00 |
May | 271.69 | 33.25 | 238.45 | 494.79 | 124.87 | 0.00 | 0.00 | 0.00 |
June | 249.47 | 13.93 | 235.54 | 552.68 | 58.39 | 0.00 | 0.00 | 0.00 |
July | 250.25 | 16.88 | 233.37 | 587.33 | 27.24 | 0.00 | 0.00 | 0.00 |
August | 301.54 | 56.67 | 244.87 | 697.30 | 14.49 | 0.00 | 0.00 | 0.00 |
September | 340.43 | 132.46 | 207.97 | 646.87 | 86.91 | 0.00 | 0.00 | 0.00 |
October | 478.03 | 308.97 | 169.06 | 746.96 | 259.10 | 0.00 | 0.00 | 0.00 |
November | 522.27 | 348.52 | 173.76 | 721.48 | 372.82 | 0.00 | 0.00 | 0.00 |
December | 523.54 | 368.30 | 155.25 | 647.97 | 490.95 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 394.80 | 192.80 | 202.00 | 625.96 | 253.34 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 249.47 | 13.93 | 155.25 | 494.79 | 14.49 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 527.26 | 368.30 | 244.87 | 746.96 | 598.69 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: CAFE_FLR_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 1484.72 | 1031.40 | 453.32 | 1680.96 | 1708.07 | 0.00 | 0.00 | 0.00 |
February | 1383.03 | 922.68 | 460.35 | 1722.00 | 1406.78 | 0.00 | 0.00 | 0.00 |
March | 1264.70 | 663.66 | 601.04 | 1788.59 | 863.18 | 0.00 | 0.00 | 0.00 |
April | 951.78 | 317.55 | 634.23 | 1547.13 | 654.34 | 0.00 | 0.00 | 0.00 |
May | 765.07 | 93.63 | 671.45 | 1380.92 | 367.60 | 0.00 | 0.00 | 0.00 |
June | 702.49 | 39.22 | 663.27 | 1541.93 | 182.56 | 0.00 | 0.00 | 0.00 |
July | 704.68 | 47.53 | 657.15 | 1640.65 | 93.35 | 0.00 | 0.00 | 0.00 |
August | 849.11 | 159.58 | 689.52 | 1948.93 | 56.92 | 0.00 | 0.00 | 0.00 |
September | 958.64 | 373.00 | 585.64 | 1810.71 | 264.54 | 0.00 | 0.00 | 0.00 |
October | 1346.11 | 870.05 | 476.06 | 2092.32 | 747.11 | 0.00 | 0.00 | 0.00 |
November | 1470.69 | 981.40 | 489.29 | 2016.91 | 1063.89 | 0.00 | 0.00 | 0.00 |
December | 1474.27 | 1037.10 | 437.17 | 1807.37 | 1401.30 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1111.73 | 542.91 | 568.82 | 1748.63 | 730.72 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 702.49 | 39.22 | 437.17 | 1380.92 | 56.92 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1484.72 | 1037.10 | 689.52 | 2092.32 | 1708.07 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: LOBBY_FLR_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 1928.74 | 1339.84 | 588.89 | 2217.00 | 2287.38 | 0.00 | 0.00 | 0.00 |
February | 1796.64 | 1198.62 | 598.02 | 2278.10 | 1880.32 | 0.00 | 0.00 | 0.00 |
March | 1642.92 | 862.13 | 780.79 | 2376.40 | 1149.69 | 0.00 | 0.00 | 0.00 |
April | 1236.41 | 412.51 | 823.90 | 2062.90 | 874.25 | 0.00 | 0.00 | 0.00 |
May | 993.87 | 121.63 | 872.25 | 1847.11 | 492.44 | 0.00 | 0.00 | 0.00 |
June | 912.57 | 50.95 | 861.62 | 2065.28 | 242.25 | 0.00 | 0.00 | 0.00 |
July | 915.42 | 61.75 | 853.67 | 2199.92 | 121.71 | 0.00 | 0.00 | 0.00 |
August | 1103.04 | 207.31 | 895.73 | 2616.85 | 69.48 | 0.00 | 0.00 | 0.00 |
September | 1245.33 | 484.54 | 760.78 | 2420.96 | 347.04 | 0.00 | 0.00 | 0.00 |
October | 1748.68 | 1130.24 | 618.43 | 2784.38 | 989.75 | 0.00 | 0.00 | 0.00 |
November | 1910.51 | 1274.89 | 635.62 | 2675.24 | 1415.61 | 0.00 | 0.00 | 0.00 |
December | 1915.16 | 1347.25 | 567.91 | 2387.43 | 1871.72 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1444.20 | 705.27 | 738.93 | 2328.27 | 973.89 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 912.57 | 50.95 | 567.91 | 1847.11 | 69.48 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1928.74 | 1347.25 | 895.73 | 2784.38 | 2287.38 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_1_FLR_3_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 104.25 | 72.42 | 31.83 | 119.00 | 122.42 | 0.00 | 0.00 | 0.00 |
February | 97.11 | 64.78 | 32.32 | 120.90 | 100.78 | 0.00 | 0.00 | 0.00 |
March | 88.80 | 46.60 | 42.20 | 123.58 | 62.09 | 0.00 | 0.00 | 0.00 |
April | 66.83 | 22.30 | 44.53 | 105.90 | 47.63 | 0.00 | 0.00 | 0.00 |
May | 53.72 | 6.57 | 47.15 | 93.75 | 26.19 | 0.00 | 0.00 | 0.00 |
June | 49.32 | 2.75 | 46.57 | 105.72 | 12.15 | 0.00 | 0.00 | 0.00 |
July | 49.48 | 3.34 | 46.14 | 113.16 | 5.72 | 0.00 | 0.00 | 0.00 |
August | 59.62 | 11.20 | 48.41 | 135.48 | 2.86 | 0.00 | 0.00 | 0.00 |
September | 67.31 | 26.19 | 41.12 | 124.96 | 17.88 | 0.00 | 0.00 | 0.00 |
October | 94.52 | 61.09 | 33.43 | 145.60 | 52.96 | 0.00 | 0.00 | 0.00 |
November | 103.26 | 68.91 | 34.36 | 141.39 | 75.93 | 0.00 | 0.00 | 0.00 |
December | 103.51 | 72.82 | 30.70 | 127.47 | 99.93 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 78.06 | 38.12 | 39.94 | 121.43 | 51.96 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.32 | 2.75 | 30.70 | 93.75 | 2.86 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 104.25 | 72.82 | 48.41 | 145.60 | 122.42 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_1_FLR_3_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 83.12 | 38.65 | 44.47 | 63.49 | 258.71 | 0.00 | 0.00 | 0.00 |
February | 95.23 | 44.63 | 50.60 | 96.44 | 209.32 | 0.00 | 0.00 | 0.00 |
March | 139.71 | 67.38 | 72.33 | 178.39 | 120.40 | 0.00 | 0.00 | 0.00 |
April | 157.43 | 72.01 | 85.43 | 236.50 | 87.73 | 0.00 | 0.00 | 0.00 |
May | 158.41 | 60.12 | 98.28 | 266.74 | 48.47 | 0.00 | 0.00 | 0.00 |
June | 166.42 | 64.08 | 102.34 | 321.57 | 22.52 | 0.00 | 0.00 | 0.00 |
July | 156.65 | 57.94 | 98.71 | 318.98 | 10.56 | 0.00 | 0.00 | 0.00 |
August | 153.87 | 57.55 | 96.32 | 315.44 | 5.32 | 0.00 | 0.00 | 0.00 |
September | 125.70 | 52.55 | 73.15 | 221.12 | 33.48 | 0.00 | 0.00 | 0.00 |
October | 111.85 | 58.15 | 53.69 | 159.52 | 104.40 | 0.00 | 0.00 | 0.00 |
November | 88.83 | 39.72 | 49.11 | 101.95 | 156.67 | 0.00 | 0.00 | 0.00 |
December | 73.57 | 32.23 | 41.35 | 62.16 | 211.57 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 126.06 | 53.79 | 72.27 | 195.73 | 105.25 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 73.57 | 32.23 | 41.35 | 62.16 | 5.32 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 166.42 | 72.01 | 102.34 | 321.57 | 258.71 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_2_FLR_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 19.63 | 0.00 | 19.63 | 2.87 | 146.40 | 0.00 | 0.00 | 0.00 |
February | 21.76 | 0.00 | 21.76 | 10.20 | 116.64 | 0.00 | 0.00 | 0.00 |
March | 30.56 | 0.00 | 30.56 | 24.02 | 65.38 | 0.00 | 0.00 | 0.00 |
April | 37.06 | 0.22 | 36.84 | 46.60 | 46.71 | 0.00 | 0.00 | 0.00 |
May | 44.21 | 1.39 | 42.83 | 71.47 | 24.56 | 0.00 | 0.00 | 0.00 |
June | 48.63 | 3.19 | 45.44 | 102.43 | 11.26 | 0.00 | 0.00 | 0.00 |
July | 46.05 | 2.36 | 43.69 | 104.94 | 5.53 | 0.00 | 0.00 | 0.00 |
August | 40.90 | 0.48 | 40.42 | 96.70 | 2.77 | 0.00 | 0.00 | 0.00 |
September | 30.88 | 0.01 | 30.86 | 55.88 | 17.70 | 0.00 | 0.00 | 0.00 |
October | 23.46 | 0.00 | 23.46 | 25.27 | 55.61 | 0.00 | 0.00 | 0.00 |
November | 21.00 | 0.00 | 21.00 | 13.18 | 83.99 | 0.00 | 0.00 | 0.00 |
December | 18.15 | 0.00 | 18.15 | 3.75 | 116.03 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 31.91 | 0.64 | 31.27 | 46.65 | 57.43 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 18.15 | 0.00 | 18.15 | 2.87 | 2.77 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 48.63 | 3.19 | 45.44 | 104.94 | 146.40 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_2_FLR_3_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 83.12 | 38.65 | 44.47 | 66.86 | 254.64 | 0.00 | 0.00 | 0.00 |
February | 95.23 | 44.63 | 50.60 | 100.12 | 206.03 | 0.00 | 0.00 | 0.00 |
March | 139.71 | 67.38 | 72.33 | 182.59 | 118.10 | 0.00 | 0.00 | 0.00 |
April | 157.43 | 72.01 | 85.43 | 238.87 | 86.85 | 0.00 | 0.00 | 0.00 |
May | 158.41 | 60.12 | 98.28 | 267.53 | 48.21 | 0.00 | 0.00 | 0.00 |
June | 166.42 | 64.08 | 102.34 | 321.69 | 22.48 | 0.00 | 0.00 | 0.00 |
July | 156.65 | 57.94 | 98.71 | 319.23 | 10.51 | 0.00 | 0.00 | 0.00 |
August | 153.87 | 57.55 | 96.32 | 316.58 | 5.16 | 0.00 | 0.00 | 0.00 |
September | 125.70 | 52.55 | 73.15 | 223.20 | 32.80 | 0.00 | 0.00 | 0.00 |
October | 111.85 | 58.15 | 53.69 | 163.93 | 102.07 | 0.00 | 0.00 | 0.00 |
November | 88.83 | 39.72 | 49.11 | 106.90 | 152.95 | 0.00 | 0.00 | 0.00 |
December | 73.57 | 32.23 | 41.35 | 66.39 | 207.12 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 126.06 | 53.79 | 72.27 | 198.35 | 103.40 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 73.57 | 32.23 | 41.35 | 66.39 | 5.16 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 166.42 | 72.01 | 102.34 | 321.69 | 254.64 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 83.38 | 57.92 | 25.46 | 92.04 | 101.08 | 0.00 | 0.00 | 0.00 |
February | 77.67 | 51.82 | 25.85 | 93.61 | 85.79 | 0.00 | 0.00 | 0.00 |
March | 71.03 | 37.27 | 33.75 | 94.07 | 59.37 | 0.00 | 0.00 | 0.00 |
April | 53.45 | 17.83 | 35.62 | 80.83 | 46.47 | 0.00 | 0.00 | 0.00 |
May | 42.97 | 5.26 | 37.71 | 71.48 | 28.06 | 0.00 | 0.00 | 0.00 |
June | 39.45 | 2.20 | 37.25 | 80.76 | 14.80 | 0.00 | 0.00 | 0.00 |
July | 39.57 | 2.67 | 36.91 | 86.13 | 8.75 | 0.00 | 0.00 | 0.00 |
August | 47.69 | 8.96 | 38.72 | 103.59 | 6.05 | 0.00 | 0.00 | 0.00 |
September | 53.84 | 20.95 | 32.89 | 95.95 | 21.29 | 0.00 | 0.00 | 0.00 |
October | 75.60 | 48.86 | 26.74 | 112.03 | 52.47 | 0.00 | 0.00 | 0.00 |
November | 82.59 | 55.11 | 27.48 | 107.65 | 72.15 | 0.00 | 0.00 | 0.00 |
December | 82.79 | 58.24 | 24.55 | 97.09 | 88.84 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 62.43 | 30.49 | 31.95 | 92.95 | 48.57 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 39.45 | 2.20 | 24.55 | 71.48 | 6.05 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 83.38 | 58.24 | 38.72 | 112.03 | 101.08 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 15.71 | 0.00 | 15.71 | 1.99 | 123.51 | 0.00 | 0.00 | 0.00 |
February | 17.41 | 0.00 | 17.41 | 7.90 | 97.96 | 0.00 | 0.00 | 0.00 |
March | 24.45 | 0.00 | 24.45 | 19.58 | 53.52 | 0.00 | 0.00 | 0.00 |
April | 29.65 | 0.17 | 29.48 | 38.88 | 37.29 | 0.00 | 0.00 | 0.00 |
May | 35.37 | 1.11 | 34.27 | 59.69 | 19.04 | 0.00 | 0.00 | 0.00 |
June | 38.91 | 2.55 | 36.35 | 85.51 | 8.15 | 0.00 | 0.00 | 0.00 |
July | 36.85 | 1.89 | 34.96 | 87.88 | 3.75 | 0.00 | 0.00 | 0.00 |
August | 32.73 | 0.38 | 32.34 | 81.78 | 1.65 | 0.00 | 0.00 | 0.00 |
September | 24.70 | 0.01 | 24.69 | 47.26 | 13.56 | 0.00 | 0.00 | 0.00 |
October | 18.77 | 0.00 | 18.77 | 20.88 | 45.56 | 0.00 | 0.00 | 0.00 |
November | 16.80 | 0.00 | 16.80 | 10.20 | 70.19 | 0.00 | 0.00 | 0.00 |
December | 14.52 | 0.00 | 14.52 | 2.41 | 98.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 25.53 | 0.51 | 25.02 | 38.84 | 47.49 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 14.52 | 0.00 | 14.52 | 1.99 | 1.65 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 38.91 | 2.55 | 36.35 | 87.88 | 123.51 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_5_FLR_3_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 81.12 | 36.93 | 44.18 | 53.26 | 250.97 | 0.00 | 0.00 | 0.00 |
February | 101.81 | 54.80 | 47.00 | 96.05 | 197.79 | 0.00 | 0.00 | 0.00 |
March | 128.09 | 58.43 | 69.66 | 149.68 | 111.69 | 0.00 | 0.00 | 0.00 |
April | 154.84 | 70.67 | 84.16 | 225.04 | 80.84 | 0.00 | 0.00 | 0.00 |
May | 169.62 | 71.73 | 97.89 | 280.55 | 44.65 | 0.00 | 0.00 | 0.00 |
June | 175.44 | 73.48 | 101.96 | 334.80 | 20.45 | 0.00 | 0.00 | 0.00 |
July | 171.00 | 71.74 | 99.26 | 342.08 | 10.14 | 0.00 | 0.00 | 0.00 |
August | 156.73 | 62.17 | 94.56 | 320.77 | 4.99 | 0.00 | 0.00 | 0.00 |
September | 128.45 | 56.76 | 71.69 | 224.57 | 31.83 | 0.00 | 0.00 | 0.00 |
October | 109.86 | 57.18 | 52.68 | 148.34 | 97.31 | 0.00 | 0.00 | 0.00 |
November | 87.50 | 39.47 | 48.03 | 87.62 | 144.33 | 0.00 | 0.00 | 0.00 |
December | 75.93 | 34.56 | 41.37 | 53.76 | 198.70 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 128.49 | 57.32 | 71.17 | 193.57 | 99.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 75.93 | 34.56 | 41.37 | 53.26 | 4.99 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 175.44 | 73.48 | 101.96 | 342.08 | 250.97 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_5_FLR_3_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 104.25 | 72.42 | 31.83 | 118.43 | 122.12 | 0.00 | 0.00 | 0.00 |
February | 97.11 | 64.78 | 32.32 | 119.88 | 100.58 | 0.00 | 0.00 | 0.00 |
March | 88.80 | 46.60 | 42.20 | 122.56 | 61.60 | 0.00 | 0.00 | 0.00 |
April | 66.83 | 22.30 | 44.53 | 104.80 | 47.32 | 0.00 | 0.00 | 0.00 |
May | 53.72 | 6.57 | 47.15 | 92.69 | 26.02 | 0.00 | 0.00 | 0.00 |
June | 49.32 | 2.75 | 46.57 | 104.84 | 11.98 | 0.00 | 0.00 | 0.00 |
July | 49.48 | 3.34 | 46.14 | 112.42 | 5.62 | 0.00 | 0.00 | 0.00 |
August | 59.62 | 11.20 | 48.41 | 135.11 | 2.76 | 0.00 | 0.00 | 0.00 |
September | 67.31 | 26.19 | 41.12 | 124.40 | 17.67 | 0.00 | 0.00 | 0.00 |
October | 94.52 | 61.09 | 33.43 | 144.70 | 52.59 | 0.00 | 0.00 | 0.00 |
November | 103.26 | 68.91 | 34.36 | 140.74 | 75.61 | 0.00 | 0.00 | 0.00 |
December | 103.51 | 72.82 | 30.70 | 126.90 | 99.72 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 78.06 | 38.12 | 39.94 | 120.65 | 51.72 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.32 | 2.75 | 30.70 | 92.69 | 2.76 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 104.25 | 72.82 | 48.41 | 144.70 | 122.12 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_6_FLR_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 19.63 | 0.00 | 19.63 | 2.73 | 146.39 | 0.00 | 0.00 | 0.00 |
February | 21.76 | 0.00 | 21.76 | 9.76 | 116.95 | 0.00 | 0.00 | 0.00 |
March | 30.56 | 0.00 | 30.56 | 23.42 | 65.25 | 0.00 | 0.00 | 0.00 |
April | 37.06 | 0.22 | 36.84 | 45.47 | 46.55 | 0.00 | 0.00 | 0.00 |
May | 44.21 | 1.39 | 42.83 | 70.29 | 24.38 | 0.00 | 0.00 | 0.00 |
June | 48.63 | 3.19 | 45.44 | 101.49 | 11.06 | 0.00 | 0.00 | 0.00 |
July | 46.05 | 2.36 | 43.69 | 104.19 | 5.45 | 0.00 | 0.00 | 0.00 |
August | 40.90 | 0.48 | 40.42 | 96.29 | 2.67 | 0.00 | 0.00 | 0.00 |
September | 30.88 | 0.01 | 30.86 | 55.18 | 17.55 | 0.00 | 0.00 | 0.00 |
October | 23.46 | 0.00 | 23.46 | 24.39 | 55.48 | 0.00 | 0.00 | 0.00 |
November | 21.00 | 0.00 | 21.00 | 12.93 | 83.83 | 0.00 | 0.00 | 0.00 |
December | 18.15 | 0.00 | 18.15 | 3.58 | 116.10 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 31.91 | 0.64 | 31.27 | 46.02 | 57.35 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 18.15 | 0.00 | 18.15 | 2.73 | 2.67 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 48.63 | 3.19 | 45.44 | 104.19 | 146.39 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_6_FLR_3_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 81.12 | 36.93 | 44.18 | 55.20 | 245.28 | 0.00 | 0.00 | 0.00 |
February | 101.81 | 54.80 | 47.00 | 99.31 | 193.99 | 0.00 | 0.00 | 0.00 |
March | 128.09 | 58.43 | 69.66 | 153.80 | 109.27 | 0.00 | 0.00 | 0.00 |
April | 154.84 | 70.67 | 84.16 | 227.08 | 79.95 | 0.00 | 0.00 | 0.00 |
May | 169.62 | 71.73 | 97.89 | 281.21 | 44.40 | 0.00 | 0.00 | 0.00 |
June | 175.44 | 73.48 | 101.96 | 334.93 | 20.42 | 0.00 | 0.00 | 0.00 |
July | 171.00 | 71.74 | 99.26 | 342.34 | 10.09 | 0.00 | 0.00 | 0.00 |
August | 156.73 | 62.17 | 94.56 | 321.88 | 4.84 | 0.00 | 0.00 | 0.00 |
September | 128.45 | 56.76 | 71.69 | 226.39 | 31.20 | 0.00 | 0.00 | 0.00 |
October | 109.86 | 57.18 | 52.68 | 152.40 | 94.97 | 0.00 | 0.00 | 0.00 |
November | 87.50 | 39.47 | 48.03 | 92.45 | 140.13 | 0.00 | 0.00 | 0.00 |
December | 75.93 | 34.56 | 41.37 | 56.78 | 192.84 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 128.49 | 57.32 | 71.17 | 195.83 | 96.81 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 75.93 | 34.56 | 41.37 | 55.20 | 4.84 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 175.44 | 73.48 | 101.96 | 342.34 | 245.28 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 24.87 | 0.00 | 24.87 | 3.16 | 200.50 | 0.00 | 0.00 | 0.00 |
February | 27.56 | 0.00 | 27.56 | 12.71 | 157.45 | 0.00 | 0.00 | 0.00 |
March | 38.70 | 0.00 | 38.70 | 32.40 | 83.98 | 0.00 | 0.00 | 0.00 |
April | 46.93 | 0.27 | 46.65 | 64.80 | 58.17 | 0.00 | 0.00 | 0.00 |
May | 55.99 | 1.76 | 54.24 | 99.17 | 29.71 | 0.00 | 0.00 | 0.00 |
June | 61.58 | 4.04 | 57.54 | 138.39 | 13.94 | 0.00 | 0.00 | 0.00 |
July | 58.32 | 2.99 | 55.33 | 140.24 | 7.26 | 0.00 | 0.00 | 0.00 |
August | 51.80 | 0.61 | 51.19 | 129.27 | 3.85 | 0.00 | 0.00 | 0.00 |
September | 39.10 | 0.02 | 39.09 | 77.24 | 22.30 | 0.00 | 0.00 | 0.00 |
October | 29.71 | 0.00 | 29.71 | 34.61 | 71.38 | 0.00 | 0.00 | 0.00 |
November | 26.59 | 0.00 | 26.59 | 16.69 | 111.02 | 0.00 | 0.00 | 0.00 |
December | 22.99 | 0.00 | 22.99 | 3.68 | 158.38 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 40.42 | 0.81 | 39.60 | 62.98 | 76.11 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 22.99 | 0.00 | 22.99 | 3.16 | 3.85 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 61.58 | 4.04 | 57.54 | 140.24 | 200.50 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 9.17 | 0.00 | 9.17 | 1.16 | 73.91 | 0.00 | 0.00 | 0.00 |
February | 10.16 | 0.00 | 10.16 | 4.69 | 58.04 | 0.00 | 0.00 | 0.00 |
March | 14.27 | 0.00 | 14.27 | 11.94 | 30.96 | 0.00 | 0.00 | 0.00 |
April | 17.30 | 0.10 | 17.20 | 23.89 | 21.45 | 0.00 | 0.00 | 0.00 |
May | 20.64 | 0.65 | 19.99 | 36.56 | 10.95 | 0.00 | 0.00 | 0.00 |
June | 22.70 | 1.49 | 21.21 | 51.02 | 5.14 | 0.00 | 0.00 | 0.00 |
July | 21.50 | 1.10 | 20.40 | 51.70 | 2.68 | 0.00 | 0.00 | 0.00 |
August | 19.10 | 0.22 | 18.87 | 47.65 | 1.42 | 0.00 | 0.00 | 0.00 |
September | 14.41 | 0.01 | 14.41 | 28.47 | 8.22 | 0.00 | 0.00 | 0.00 |
October | 10.95 | 0.00 | 10.95 | 12.76 | 26.31 | 0.00 | 0.00 | 0.00 |
November | 9.80 | 0.00 | 9.80 | 6.15 | 40.93 | 0.00 | 0.00 | 0.00 |
December | 8.47 | 0.00 | 8.47 | 1.36 | 58.38 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 14.90 | 0.30 | 14.60 | 23.22 | 28.06 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 8.47 | 0.00 | 8.47 | 1.16 | 1.42 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 22.70 | 1.49 | 21.21 | 51.70 | 73.91 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 48.64 | 33.79 | 14.85 | 54.75 | 60.08 | 0.00 | 0.00 | 0.00 |
February | 45.31 | 30.23 | 15.08 | 56.44 | 48.94 | 0.00 | 0.00 | 0.00 |
March | 41.43 | 21.74 | 19.69 | 59.36 | 28.83 | 0.00 | 0.00 | 0.00 |
April | 31.18 | 10.40 | 20.78 | 52.06 | 21.62 | 0.00 | 0.00 | 0.00 |
May | 25.07 | 3.07 | 22.00 | 47.06 | 11.60 | 0.00 | 0.00 | 0.00 |
June | 23.01 | 1.28 | 21.73 | 52.53 | 5.55 | 0.00 | 0.00 | 0.00 |
July | 23.09 | 1.56 | 21.53 | 55.57 | 2.76 | 0.00 | 0.00 | 0.00 |
August | 27.82 | 5.23 | 22.59 | 65.96 | 1.43 | 0.00 | 0.00 | 0.00 |
September | 31.41 | 12.22 | 19.19 | 61.13 | 8.15 | 0.00 | 0.00 | 0.00 |
October | 44.10 | 28.50 | 15.60 | 70.03 | 24.56 | 0.00 | 0.00 | 0.00 |
November | 48.18 | 32.15 | 16.03 | 67.02 | 35.93 | 0.00 | 0.00 | 0.00 |
December | 48.30 | 33.98 | 14.32 | 59.19 | 48.62 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 36.42 | 17.79 | 18.64 | 58.44 | 24.72 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 23.01 | 1.28 | 14.32 | 47.06 | 1.43 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 48.64 | 33.98 | 22.59 | 70.03 | 60.08 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 132.02 | 91.71 | 40.31 | 148.61 | 163.08 | 0.00 | 0.00 | 0.00 |
February | 122.98 | 82.05 | 40.94 | 153.19 | 132.83 | 0.00 | 0.00 | 0.00 |
March | 112.46 | 59.01 | 53.45 | 161.12 | 78.26 | 0.00 | 0.00 | 0.00 |
April | 84.63 | 28.24 | 56.40 | 141.29 | 58.67 | 0.00 | 0.00 | 0.00 |
May | 68.03 | 8.33 | 59.71 | 127.74 | 31.50 | 0.00 | 0.00 | 0.00 |
June | 62.47 | 3.49 | 58.98 | 142.57 | 15.06 | 0.00 | 0.00 | 0.00 |
July | 62.66 | 4.23 | 58.43 | 150.82 | 7.50 | 0.00 | 0.00 | 0.00 |
August | 75.50 | 14.19 | 61.31 | 179.03 | 3.89 | 0.00 | 0.00 | 0.00 |
September | 85.24 | 33.17 | 52.08 | 165.93 | 22.13 | 0.00 | 0.00 | 0.00 |
October | 119.70 | 77.37 | 42.33 | 190.07 | 66.65 | 0.00 | 0.00 | 0.00 |
November | 130.78 | 87.27 | 43.51 | 181.89 | 97.53 | 0.00 | 0.00 | 0.00 |
December | 131.09 | 92.22 | 38.87 | 160.65 | 131.96 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 98.86 | 48.28 | 50.58 | 158.63 | 67.09 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 62.47 | 3.49 | 38.87 | 127.74 | 3.89 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 132.02 | 92.22 | 61.31 | 190.07 | 163.08 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_1_FLR_6_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 104.25 | 72.42 | 31.83 | 118.57 | 121.59 | 0.00 | 0.00 | 0.00 |
February | 97.11 | 64.78 | 32.32 | 120.11 | 100.12 | 0.00 | 0.00 | 0.00 |
March | 88.80 | 46.60 | 42.20 | 122.09 | 61.71 | 0.00 | 0.00 | 0.00 |
April | 66.83 | 22.30 | 44.53 | 104.07 | 47.64 | 0.00 | 0.00 | 0.00 |
May | 53.72 | 6.57 | 47.15 | 91.67 | 26.36 | 0.00 | 0.00 | 0.00 |
June | 49.32 | 2.75 | 46.57 | 103.92 | 12.13 | 0.00 | 0.00 | 0.00 |
July | 49.48 | 3.34 | 46.14 | 111.30 | 5.70 | 0.00 | 0.00 | 0.00 |
August | 59.62 | 11.20 | 48.41 | 133.48 | 2.80 | 0.00 | 0.00 | 0.00 |
September | 67.31 | 26.19 | 41.12 | 123.18 | 17.83 | 0.00 | 0.00 | 0.00 |
October | 94.52 | 61.09 | 33.43 | 144.05 | 52.63 | 0.00 | 0.00 | 0.00 |
November | 103.26 | 68.91 | 34.36 | 140.54 | 75.19 | 0.00 | 0.00 | 0.00 |
December | 103.51 | 72.82 | 30.70 | 127.00 | 98.94 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 78.06 | 38.12 | 39.94 | 120.02 | 51.64 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.32 | 2.75 | 30.70 | 91.67 | 2.80 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 104.25 | 72.82 | 48.41 | 144.05 | 121.59 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_1_FLR_6_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 83.12 | 38.65 | 44.47 | 63.43 | 257.15 | 0.00 | 0.00 | 0.00 |
February | 95.23 | 44.63 | 50.60 | 95.64 | 207.85 | 0.00 | 0.00 | 0.00 |
March | 139.71 | 67.38 | 72.33 | 175.78 | 119.49 | 0.00 | 0.00 | 0.00 |
April | 157.43 | 72.01 | 85.43 | 232.65 | 87.66 | 0.00 | 0.00 | 0.00 |
May | 158.41 | 60.12 | 98.28 | 262.14 | 48.74 | 0.00 | 0.00 | 0.00 |
June | 166.42 | 64.08 | 102.34 | 316.94 | 22.43 | 0.00 | 0.00 | 0.00 |
July | 156.65 | 57.94 | 98.71 | 314.69 | 10.52 | 0.00 | 0.00 | 0.00 |
August | 153.87 | 57.55 | 96.32 | 311.19 | 5.21 | 0.00 | 0.00 | 0.00 |
September | 125.70 | 52.55 | 73.15 | 217.80 | 33.33 | 0.00 | 0.00 | 0.00 |
October | 111.85 | 58.15 | 53.69 | 157.21 | 103.65 | 0.00 | 0.00 | 0.00 |
November | 88.83 | 39.72 | 49.11 | 101.01 | 155.12 | 0.00 | 0.00 | 0.00 |
December | 73.57 | 32.23 | 41.35 | 62.15 | 209.41 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 126.06 | 53.79 | 72.27 | 193.08 | 104.54 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 73.57 | 32.23 | 41.35 | 62.15 | 5.21 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 166.42 | 72.01 | 102.34 | 316.94 | 257.15 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_2_FLR_6_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 19.63 | 0.00 | 19.63 | 2.97 | 145.73 | 0.00 | 0.00 | 0.00 |
February | 21.76 | 0.00 | 21.76 | 10.26 | 115.94 | 0.00 | 0.00 | 0.00 |
March | 30.56 | 0.00 | 30.56 | 23.60 | 64.90 | 0.00 | 0.00 | 0.00 |
April | 37.06 | 0.22 | 36.84 | 45.34 | 46.70 | 0.00 | 0.00 | 0.00 |
May | 44.21 | 1.39 | 42.83 | 69.56 | 24.75 | 0.00 | 0.00 | 0.00 |
June | 48.63 | 3.19 | 45.44 | 100.64 | 11.25 | 0.00 | 0.00 | 0.00 |
July | 46.05 | 2.36 | 43.69 | 103.14 | 5.55 | 0.00 | 0.00 | 0.00 |
August | 40.90 | 0.48 | 40.42 | 95.02 | 2.71 | 0.00 | 0.00 | 0.00 |
September | 30.88 | 0.01 | 30.86 | 54.62 | 17.62 | 0.00 | 0.00 | 0.00 |
October | 23.46 | 0.00 | 23.46 | 24.79 | 55.17 | 0.00 | 0.00 | 0.00 |
November | 21.00 | 0.00 | 21.00 | 13.32 | 83.05 | 0.00 | 0.00 | 0.00 |
December | 18.15 | 0.00 | 18.15 | 4.01 | 114.85 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 31.91 | 0.64 | 31.27 | 45.81 | 57.07 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 18.15 | 0.00 | 18.15 | 2.97 | 2.71 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 48.63 | 3.19 | 45.44 | 103.14 | 145.73 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_2_FLR_6_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 83.12 | 38.65 | 44.47 | 66.68 | 253.45 | 0.00 | 0.00 | 0.00 |
February | 95.23 | 44.63 | 50.60 | 99.38 | 204.63 | 0.00 | 0.00 | 0.00 |
March | 139.71 | 67.38 | 72.33 | 180.25 | 117.04 | 0.00 | 0.00 | 0.00 |
April | 157.43 | 72.01 | 85.43 | 234.99 | 86.75 | 0.00 | 0.00 | 0.00 |
May | 158.41 | 60.12 | 98.28 | 262.86 | 48.48 | 0.00 | 0.00 | 0.00 |
June | 166.42 | 64.08 | 102.34 | 317.04 | 22.40 | 0.00 | 0.00 | 0.00 |
July | 156.65 | 57.94 | 98.71 | 314.93 | 10.47 | 0.00 | 0.00 | 0.00 |
August | 153.87 | 57.55 | 96.32 | 312.32 | 5.06 | 0.00 | 0.00 | 0.00 |
September | 125.70 | 52.55 | 73.15 | 219.83 | 32.61 | 0.00 | 0.00 | 0.00 |
October | 111.85 | 58.15 | 53.69 | 161.82 | 101.15 | 0.00 | 0.00 | 0.00 |
November | 88.83 | 39.72 | 49.11 | 106.40 | 151.19 | 0.00 | 0.00 | 0.00 |
December | 73.57 | 32.23 | 41.35 | 66.60 | 205.19 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 126.06 | 53.79 | 72.27 | 195.78 | 102.70 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 73.57 | 32.23 | 41.35 | 66.60 | 5.06 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 166.42 | 72.01 | 102.34 | 317.04 | 253.45 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 152.89 | 106.21 | 46.68 | 165.66 | 186.31 | 0.00 | 0.00 | 0.00 |
February | 142.42 | 95.01 | 47.41 | 169.99 | 153.15 | 0.00 | 0.00 | 0.00 |
March | 130.23 | 68.34 | 61.89 | 175.83 | 92.67 | 0.00 | 0.00 | 0.00 |
April | 98.01 | 32.70 | 65.31 | 152.55 | 69.61 | 0.00 | 0.00 | 0.00 |
May | 78.78 | 9.64 | 69.14 | 136.71 | 37.57 | 0.00 | 0.00 | 0.00 |
June | 72.34 | 4.04 | 68.30 | 156.44 | 16.52 | 0.00 | 0.00 | 0.00 |
July | 72.57 | 4.89 | 67.67 | 167.59 | 7.49 | 0.00 | 0.00 | 0.00 |
August | 87.44 | 16.43 | 71.00 | 199.82 | 3.50 | 0.00 | 0.00 | 0.00 |
September | 98.72 | 38.41 | 60.31 | 181.55 | 25.77 | 0.00 | 0.00 | 0.00 |
October | 138.62 | 89.59 | 49.02 | 208.33 | 79.57 | 0.00 | 0.00 | 0.00 |
November | 151.44 | 101.06 | 50.39 | 200.24 | 115.47 | 0.00 | 0.00 | 0.00 |
December | 151.81 | 106.80 | 45.02 | 178.15 | 152.66 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 114.48 | 55.91 | 58.58 | 174.46 | 77.98 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 72.34 | 4.04 | 45.02 | 136.71 | 3.50 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 152.89 | 106.80 | 71.00 | 208.33 | 186.31 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: BANQUET_FLR_6_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 137.44 | 0.00 | 137.44 | 15.34 | 1133.54 | 0.00 | 0.00 | 0.00 |
February | 152.33 | 0.00 | 152.33 | 64.78 | 902.16 | 0.00 | 0.00 | 0.00 |
March | 213.92 | 0.00 | 213.92 | 163.76 | 500.07 | 0.00 | 0.00 | 0.00 |
April | 259.38 | 1.51 | 257.87 | 338.63 | 354.59 | 0.00 | 0.00 | 0.00 |
May | 309.48 | 9.71 | 299.77 | 523.50 | 196.27 | 0.00 | 0.00 | 0.00 |
June | 340.37 | 22.32 | 318.05 | 747.01 | 97.29 | 0.00 | 0.00 | 0.00 |
July | 322.35 | 16.52 | 305.83 | 762.17 | 54.38 | 0.00 | 0.00 | 0.00 |
August | 286.31 | 3.36 | 282.94 | 704.78 | 32.35 | 0.00 | 0.00 | 0.00 |
September | 216.12 | 0.08 | 216.03 | 415.69 | 144.51 | 0.00 | 0.00 | 0.00 |
October | 164.21 | 0.00 | 164.21 | 179.62 | 427.67 | 0.00 | 0.00 | 0.00 |
November | 146.96 | 0.00 | 146.96 | 83.64 | 644.18 | 0.00 | 0.00 | 0.00 |
December | 127.05 | 0.00 | 127.05 | 17.13 | 904.84 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 223.38 | 4.48 | 218.90 | 336.21 | 447.12 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 127.05 | 0.00 | 127.05 | 15.34 | 32.35 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 340.37 | 22.32 | 318.05 | 762.17 | 1133.54 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: DINING_FLR_6_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 137.44 | 0.00 | 137.44 | 14.48 | 1152.22 | 0.00 | 0.00 | 0.00 |
February | 152.33 | 0.00 | 152.33 | 62.36 | 920.08 | 0.00 | 0.00 | 0.00 |
March | 213.92 | 0.00 | 213.92 | 157.63 | 515.01 | 0.00 | 0.00 | 0.00 |
April | 259.38 | 1.51 | 257.87 | 329.74 | 367.12 | 0.00 | 0.00 | 0.00 |
May | 309.48 | 9.71 | 299.77 | 511.87 | 206.77 | 0.00 | 0.00 | 0.00 |
June | 340.37 | 22.32 | 318.05 | 732.67 | 105.00 | 0.00 | 0.00 | 0.00 |
July | 322.35 | 16.52 | 305.83 | 747.63 | 60.36 | 0.00 | 0.00 | 0.00 |
August | 286.31 | 3.36 | 282.94 | 690.13 | 37.82 | 0.00 | 0.00 | 0.00 |
September | 216.12 | 0.08 | 216.03 | 404.61 | 154.86 | 0.00 | 0.00 | 0.00 |
October | 164.21 | 0.00 | 164.21 | 173.61 | 442.36 | 0.00 | 0.00 | 0.00 |
November | 146.96 | 0.00 | 146.96 | 79.60 | 660.28 | 0.00 | 0.00 | 0.00 |
December | 127.05 | 0.00 | 127.05 | 15.74 | 923.43 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 223.38 | 4.48 | 218.90 | 328.19 | 459.88 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 127.05 | 0.00 | 127.05 | 14.48 | 37.82 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 340.37 | 22.32 | 318.05 | 747.63 | 1152.22 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: KITCHEN_FLR_6_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 19.63 | 0.00 | 19.63 | 2.48 | 162.01 | 0.00 | 0.00 | 0.00 |
February | 21.76 | 0.00 | 21.76 | 9.62 | 130.83 | 0.00 | 0.00 | 0.00 |
March | 30.56 | 0.00 | 30.56 | 24.71 | 74.58 | 0.00 | 0.00 | 0.00 |
April | 37.06 | 0.22 | 36.84 | 51.47 | 53.09 | 0.00 | 0.00 | 0.00 |
May | 44.21 | 1.39 | 42.83 | 79.85 | 30.64 | 0.00 | 0.00 | 0.00 |
June | 48.63 | 3.19 | 45.44 | 112.31 | 15.95 | 0.00 | 0.00 | 0.00 |
July | 46.05 | 2.36 | 43.69 | 115.71 | 8.95 | 0.00 | 0.00 | 0.00 |
August | 40.90 | 0.48 | 40.42 | 107.19 | 5.72 | 0.00 | 0.00 | 0.00 |
September | 30.88 | 0.01 | 30.86 | 63.60 | 22.15 | 0.00 | 0.00 | 0.00 |
October | 23.46 | 0.00 | 23.46 | 27.47 | 63.55 | 0.00 | 0.00 | 0.00 |
November | 21.00 | 0.00 | 21.00 | 13.40 | 94.12 | 0.00 | 0.00 | 0.00 |
December | 18.15 | 0.00 | 18.15 | 2.83 | 130.80 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 31.91 | 0.64 | 31.27 | 51.13 | 65.72 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 18.15 | 0.00 | 18.15 | 2.48 | 5.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 48.63 | 3.19 | 45.44 | 115.71 | 162.01 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: KITCHEN_FLR_6_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 162.23 | 73.86 | 88.36 | 108.09 | 545.32 | 0.00 | 0.00 | 0.00 |
February | 203.60 | 109.60 | 94.00 | 198.32 | 438.82 | 0.00 | 0.00 | 0.00 |
March | 256.16 | 116.85 | 139.31 | 315.52 | 254.39 | 0.00 | 0.00 | 0.00 |
April | 309.65 | 141.33 | 168.31 | 480.40 | 186.90 | 0.00 | 0.00 | 0.00 |
May | 339.21 | 143.45 | 195.76 | 599.04 | 113.60 | 0.00 | 0.00 | 0.00 |
June | 350.85 | 146.95 | 203.90 | 712.10 | 59.62 | 0.00 | 0.00 | 0.00 |
July | 341.97 | 143.47 | 198.50 | 726.28 | 33.84 | 0.00 | 0.00 | 0.00 |
August | 313.43 | 124.33 | 189.10 | 682.47 | 21.60 | 0.00 | 0.00 | 0.00 |
September | 256.88 | 113.51 | 143.37 | 486.01 | 81.21 | 0.00 | 0.00 | 0.00 |
October | 219.71 | 114.36 | 105.35 | 319.69 | 221.18 | 0.00 | 0.00 | 0.00 |
November | 174.98 | 78.93 | 96.05 | 188.70 | 316.79 | 0.00 | 0.00 | 0.00 |
December | 151.85 | 69.12 | 82.73 | 110.06 | 436.98 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 256.97 | 114.63 | 142.34 | 411.68 | 224.81 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 151.85 | 69.12 | 82.73 | 108.09 | 21.60 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 350.85 | 146.95 | 203.90 | 726.28 | 545.32 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 104.25 | 72.42 | 31.83 | 118.84 | 132.06 | 0.00 | 0.00 | 0.00 |
February | 97.11 | 64.78 | 32.32 | 121.51 | 110.77 | 0.00 | 0.00 | 0.00 |
March | 88.80 | 46.60 | 42.20 | 127.05 | 69.50 | 0.00 | 0.00 | 0.00 |
April | 66.83 | 22.30 | 44.53 | 112.19 | 53.36 | 0.00 | 0.00 | 0.00 |
May | 53.72 | 6.57 | 47.15 | 102.62 | 31.74 | 0.00 | 0.00 | 0.00 |
June | 49.32 | 2.75 | 46.57 | 115.87 | 16.65 | 0.00 | 0.00 | 0.00 |
July | 49.48 | 3.34 | 46.14 | 123.80 | 9.05 | 0.00 | 0.00 | 0.00 |
August | 59.62 | 11.20 | 48.41 | 146.42 | 5.72 | 0.00 | 0.00 | 0.00 |
September | 67.31 | 26.19 | 41.12 | 134.46 | 21.83 | 0.00 | 0.00 | 0.00 |
October | 94.52 | 61.09 | 33.43 | 151.40 | 59.31 | 0.00 | 0.00 | 0.00 |
November | 103.26 | 68.91 | 34.36 | 145.53 | 82.96 | 0.00 | 0.00 | 0.00 |
December | 103.51 | 72.82 | 30.70 | 128.24 | 109.33 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 78.06 | 38.12 | 39.94 | 127.38 | 58.26 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 49.32 | 2.75 | 30.70 | 102.62 | 5.72 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 104.25 | 72.82 | 48.41 | 151.40 | 132.06 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 24.87 | 0.00 | 24.87 | 2.93 | 202.67 | 0.00 | 0.00 | 0.00 |
February | 27.56 | 0.00 | 27.56 | 12.00 | 159.21 | 0.00 | 0.00 | 0.00 |
March | 38.70 | 0.00 | 38.70 | 30.54 | 85.21 | 0.00 | 0.00 | 0.00 |
April | 46.93 | 0.27 | 46.65 | 62.33 | 58.71 | 0.00 | 0.00 | 0.00 |
May | 55.99 | 1.76 | 54.24 | 96.48 | 29.73 | 0.00 | 0.00 | 0.00 |
June | 61.58 | 4.04 | 57.54 | 137.74 | 12.91 | 0.00 | 0.00 | 0.00 |
July | 58.32 | 2.99 | 55.33 | 139.76 | 6.32 | 0.00 | 0.00 | 0.00 |
August | 51.80 | 0.61 | 51.19 | 129.47 | 2.94 | 0.00 | 0.00 | 0.00 |
September | 39.10 | 0.02 | 39.09 | 76.77 | 21.10 | 0.00 | 0.00 | 0.00 |
October | 29.71 | 0.00 | 29.71 | 33.01 | 72.26 | 0.00 | 0.00 | 0.00 |
November | 26.59 | 0.00 | 26.59 | 15.53 | 112.53 | 0.00 | 0.00 | 0.00 |
December | 22.99 | 0.00 | 22.99 | 3.28 | 160.35 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 40.42 | 0.81 | 39.60 | 61.94 | 76.60 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 22.99 | 0.00 | 22.99 | 2.93 | 2.94 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 61.58 | 4.04 | 57.54 | 139.76 | 202.67 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 22.25 | 0.00 | 22.25 | 2.63 | 181.33 | 0.00 | 0.00 | 0.00 |
February | 24.66 | 0.00 | 24.66 | 10.74 | 142.45 | 0.00 | 0.00 | 0.00 |
March | 34.63 | 0.00 | 34.63 | 27.33 | 76.24 | 0.00 | 0.00 | 0.00 |
April | 41.99 | 0.25 | 41.74 | 55.77 | 52.53 | 0.00 | 0.00 | 0.00 |
May | 50.10 | 1.57 | 48.53 | 86.32 | 26.60 | 0.00 | 0.00 | 0.00 |
June | 55.10 | 3.61 | 51.48 | 123.23 | 11.55 | 0.00 | 0.00 | 0.00 |
July | 52.18 | 2.67 | 49.51 | 125.04 | 5.65 | 0.00 | 0.00 | 0.00 |
August | 46.35 | 0.54 | 45.80 | 115.84 | 2.63 | 0.00 | 0.00 | 0.00 |
September | 34.98 | 0.01 | 34.97 | 68.69 | 18.88 | 0.00 | 0.00 | 0.00 |
October | 26.58 | 0.00 | 26.58 | 29.53 | 64.65 | 0.00 | 0.00 | 0.00 |
November | 23.79 | 0.00 | 23.79 | 13.90 | 100.68 | 0.00 | 0.00 | 0.00 |
December | 20.57 | 0.00 | 20.57 | 2.93 | 143.46 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 36.16 | 0.73 | 35.43 | 55.42 | 68.53 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 20.57 | 0.00 | 20.57 | 2.63 | 2.63 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 55.10 | 3.61 | 51.48 | 125.04 | 181.33 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 389.19 | 270.36 | 118.83 | 430.92 | 483.67 | 0.00 | 0.00 | 0.00 |
February | 362.53 | 241.86 | 120.67 | 444.00 | 395.33 | 0.00 | 0.00 | 0.00 |
March | 331.52 | 173.96 | 157.55 | 465.06 | 233.78 | 0.00 | 0.00 | 0.00 |
April | 249.49 | 83.24 | 166.25 | 406.82 | 174.78 | 0.00 | 0.00 | 0.00 |
May | 200.55 | 24.54 | 176.01 | 367.63 | 93.20 | 0.00 | 0.00 | 0.00 |
June | 184.14 | 10.28 | 173.86 | 417.63 | 41.37 | 0.00 | 0.00 | 0.00 |
July | 184.72 | 12.46 | 172.26 | 442.54 | 19.24 | 0.00 | 0.00 | 0.00 |
August | 222.58 | 41.83 | 180.75 | 526.95 | 8.85 | 0.00 | 0.00 | 0.00 |
September | 251.29 | 97.77 | 153.51 | 485.59 | 62.04 | 0.00 | 0.00 | 0.00 |
October | 352.86 | 228.06 | 124.79 | 551.30 | 198.77 | 0.00 | 0.00 | 0.00 |
November | 385.51 | 257.25 | 128.26 | 528.05 | 290.70 | 0.00 | 0.00 | 0.00 |
December | 386.45 | 271.85 | 114.60 | 465.88 | 392.36 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 291.42 | 142.31 | 149.11 | 461.19 | 198.53 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 184.14 | 10.28 | 114.60 | 367.63 | 8.85 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 389.19 | 271.85 | 180.75 | 551.30 | 483.67 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyReportMonthly
For: RETAIL_1_FLR_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.141220E+10 | 0.981020E+09 | 0.431183E+09 | 0.161560E+10 | 0.160354E+10 |
February | 0.118818E+10 | 0.792686E+09 | 0.395494E+09 | 0.149293E+10 | 0.118962E+10 |
March | 0.120293E+10 | 0.631243E+09 | 0.571687E+09 | 0.171506E+10 | 0.806838E+09 |
April | 0.876087E+09 | 0.292293E+09 | 0.583795E+09 | 0.143523E+10 | 0.591169E+09 |
May | 0.727706E+09 | 89053889.35 | 0.638652E+09 | 0.132525E+10 | 0.334445E+09 |
June | 0.646621E+09 | 36100811.87 | 0.610520E+09 | 0.143256E+10 | 0.151348E+09 |
July | 0.670261E+09 | 45210453.17 | 0.625050E+09 | 0.157310E+10 | 72970874.98 |
August | 0.807634E+09 | 0.151787E+09 | 0.655847E+09 | 0.186764E+10 | 38818098.81 |
September | 0.882405E+09 | 0.343335E+09 | 0.539070E+09 | 0.167669E+10 | 0.225280E+09 |
October | 0.128037E+10 | 0.827554E+09 | 0.452812E+09 | 0.200065E+10 | 0.693962E+09 |
November | 0.135373E+10 | 0.903351E+09 | 0.450383E+09 | 0.187009E+10 | 0.966359E+09 |
December | 0.140226E+10 | 0.986443E+09 | 0.415820E+09 | 0.173551E+10 | 0.131497E+10 |
Annual Sum or Average | 0.124504E+11 | 0.608008E+10 | 0.637031E+10 | 0.197403E+11 | 0.798932E+10 |
Minimum of Months | 0.646621E+09 | 36100811.87 | 0.395494E+09 | 0.132525E+10 | 38818098.81 |
Maximum of Months | 0.141220E+10 | 0.986443E+09 | 0.655847E+09 | 0.200065E+10 | 0.160354E+10 |
Report: WindowEnergyReportMonthly
For: CAFE_FLR_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.397667E+10 | 0.276249E+10 | 0.121418E+10 | 0.450228E+10 | 0.457489E+10 |
February | 0.334584E+10 | 0.223215E+10 | 0.111368E+10 | 0.416585E+10 | 0.340328E+10 |
March | 0.338737E+10 | 0.177754E+10 | 0.160983E+10 | 0.479056E+10 | 0.231194E+10 |
April | 0.246700E+10 | 0.823077E+09 | 0.164393E+10 | 0.401015E+10 | 0.169605E+10 |
May | 0.204917E+10 | 0.250770E+09 | 0.179840E+10 | 0.369865E+10 | 0.984590E+09 |
June | 0.182084E+10 | 0.101658E+09 | 0.171918E+10 | 0.399670E+10 | 0.473203E+09 |
July | 0.188741E+10 | 0.127310E+09 | 0.176010E+10 | 0.439432E+10 | 0.250022E+09 |
August | 0.227424E+10 | 0.427422E+09 | 0.184682E+10 | 0.522003E+10 | 0.152445E+09 |
September | 0.248479E+10 | 0.966809E+09 | 0.151798E+10 | 0.469335E+10 | 0.685678E+09 |
October | 0.360543E+10 | 0.233034E+10 | 0.127509E+10 | 0.560406E+10 | 0.200106E+10 |
November | 0.381203E+10 | 0.254378E+10 | 0.126825E+10 | 0.522784E+10 | 0.275761E+10 |
December | 0.394868E+10 | 0.277776E+10 | 0.117092E+10 | 0.484087E+10 | 0.375323E+10 |
Annual Sum or Average | 0.350595E+11 | 0.171211E+11 | 0.179384E+11 | 0.551447E+11 | 0.230440E+11 |
Minimum of Months | 0.182084E+10 | 0.101658E+09 | 0.111368E+10 | 0.369865E+10 | 0.152445E+09 |
Maximum of Months | 0.397667E+10 | 0.277776E+10 | 0.184682E+10 | 0.560406E+10 | 0.457489E+10 |
Report: WindowEnergyReportMonthly
For: LOBBY_FLR_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.516592E+10 | 0.358863E+10 | 0.157729E+10 | 0.593801E+10 | 0.612653E+10 |
February | 0.434643E+10 | 0.289969E+10 | 0.144674E+10 | 0.551118E+10 | 0.454886E+10 |
March | 0.440039E+10 | 0.230912E+10 | 0.209126E+10 | 0.636494E+10 | 0.307933E+10 |
April | 0.320478E+10 | 0.106922E+10 | 0.213555E+10 | 0.534703E+10 | 0.226605E+10 |
May | 0.266199E+10 | 0.325764E+09 | 0.233623E+10 | 0.494731E+10 | 0.131895E+10 |
June | 0.236538E+10 | 0.132059E+09 | 0.223332E+10 | 0.535320E+10 | 0.627907E+09 |
July | 0.245185E+10 | 0.165382E+09 | 0.228647E+10 | 0.589227E+10 | 0.325990E+09 |
August | 0.295437E+10 | 0.555246E+09 | 0.239913E+10 | 0.700896E+10 | 0.186106E+09 |
September | 0.322789E+10 | 0.125594E+10 | 0.197195E+10 | 0.627512E+10 | 0.899527E+09 |
October | 0.468365E+10 | 0.302724E+10 | 0.165641E+10 | 0.745768E+10 | 0.265095E+10 |
November | 0.495204E+10 | 0.330451E+10 | 0.164753E+10 | 0.693423E+10 | 0.366925E+10 |
December | 0.512956E+10 | 0.360846E+10 | 0.152109E+10 | 0.639450E+10 | 0.501322E+10 |
Annual Sum or Average | 0.455443E+11 | 0.222413E+11 | 0.233030E+11 | 0.734244E+11 | 0.307127E+11 |
Minimum of Months | 0.236538E+10 | 0.132059E+09 | 0.144674E+10 | 0.494731E+10 | 0.186106E+09 |
Maximum of Months | 0.516592E+10 | 0.360846E+10 | 0.239913E+10 | 0.745768E+10 | 0.612653E+10 |
Report: WindowEnergyReportMonthly
For: ROOM_1_FLR_3_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.279218E+09 | 0.193965E+09 | 85252967.91 | 0.318718E+09 | 0.327891E+09 |
February | 0.234924E+09 | 0.156728E+09 | 78196598.94 | 0.292490E+09 | 0.243798E+09 |
March | 0.237841E+09 | 0.124808E+09 | 0.113033E+09 | 0.331006E+09 | 0.166307E+09 |
April | 0.173219E+09 | 57791307.85 | 0.115427E+09 | 0.274485E+09 | 0.123450E+09 |
May | 0.143881E+09 | 17607483.41 | 0.126274E+09 | 0.251088E+09 | 70136588.58 |
June | 0.127849E+09 | 7137750.53 | 0.120712E+09 | 0.274038E+09 | 31483637.13 |
July | 0.132523E+09 | 8938883.07 | 0.123585E+09 | 0.303090E+09 | 15311137.56 |
August | 0.159684E+09 | 30010917.68 | 0.129673E+09 | 0.362865E+09 | 7667689.58 |
September | 0.174468E+09 | 67883271.16 | 0.106584E+09 | 0.323892E+09 | 46333549.69 |
October | 0.253151E+09 | 0.163622E+09 | 89529587.28 | 0.389979E+09 | 0.141852E+09 |
November | 0.267657E+09 | 0.178608E+09 | 89049108.36 | 0.366472E+09 | 0.196820E+09 |
December | 0.277252E+09 | 0.195037E+09 | 82215273.99 | 0.341418E+09 | 0.267657E+09 |
Annual Sum or Average | 0.246167E+10 | 0.120214E+10 | 0.125953E+10 | 0.382954E+10 | 0.163871E+10 |
Minimum of Months | 0.127849E+09 | 7137750.53 | 78196598.94 | 0.251088E+09 | 7667689.58 |
Maximum of Months | 0.279218E+09 | 0.195037E+09 | 0.129673E+09 | 0.389979E+09 | 0.327891E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_1_FLR_3_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.222627E+09 | 0.103516E+09 | 0.119111E+09 | 0.170050E+09 | 0.692916E+09 |
February | 0.230374E+09 | 0.107973E+09 | 0.122401E+09 | 0.233306E+09 | 0.506383E+09 |
March | 0.374198E+09 | 0.180474E+09 | 0.193725E+09 | 0.477787E+09 | 0.322479E+09 |
April | 0.408065E+09 | 0.186640E+09 | 0.221425E+09 | 0.613000E+09 | 0.227397E+09 |
May | 0.424277E+09 | 0.161030E+09 | 0.263246E+09 | 0.714430E+09 | 0.129824E+09 |
June | 0.431370E+09 | 0.166096E+09 | 0.265273E+09 | 0.833519E+09 | 58361131.87 |
July | 0.419570E+09 | 0.155192E+09 | 0.264378E+09 | 0.854363E+09 | 28293057.72 |
August | 0.412124E+09 | 0.154141E+09 | 0.257983E+09 | 0.844887E+09 | 14242205.27 |
September | 0.325820E+09 | 0.136209E+09 | 0.189611E+09 | 0.573144E+09 | 86767464.07 |
October | 0.299566E+09 | 0.155754E+09 | 0.143812E+09 | 0.427257E+09 | 0.279636E+09 |
November | 0.230249E+09 | 0.102964E+09 | 0.127285E+09 | 0.264254E+09 | 0.406101E+09 |
December | 0.197060E+09 | 86321527.55 | 0.110739E+09 | 0.166493E+09 | 0.566665E+09 |
Annual Sum or Average | 0.397530E+10 | 0.169631E+10 | 0.227899E+10 | 0.617249E+10 | 0.331906E+10 |
Minimum of Months | 0.197060E+09 | 86321527.55 | 0.110739E+09 | 0.166493E+09 | 14242205.27 |
Maximum of Months | 0.431370E+09 | 0.186640E+09 | 0.265273E+09 | 0.854363E+09 | 0.692916E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_2_FLR_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 52588594.07 | 0.00 | 52588594.07 | 7695087.21 | 0.392125E+09 |
February | 52648446.06 | 0.00 | 52648446.06 | 24668149.47 | 0.282175E+09 |
March | 81855013.60 | 1648.52 | 81853365.08 | 64332195.90 | 0.175102E+09 |
April | 96048332.89 | 560963.03 | 95487369.87 | 0.120776E+09 | 0.121077E+09 |
May | 0.118419E+09 | 3714011.78 | 0.114705E+09 | 0.191423E+09 | 65792329.35 |
June | 0.126039E+09 | 8265554.72 | 0.117773E+09 | 0.265491E+09 | 29191768.49 |
July | 0.123345E+09 | 6320378.90 | 0.117025E+09 | 0.281080E+09 | 14821499.06 |
August | 0.109554E+09 | 1287040.28 | 0.108267E+09 | 0.259002E+09 | 7430524.98 |
September | 80028430.11 | 31459.51 | 79996970.60 | 0.144853E+09 | 45884886.91 |
October | 62833545.17 | 0.00 | 62833545.17 | 67676129.08 | 0.148933E+09 |
November | 54419711.70 | 0.00 | 54419711.70 | 34169935.55 | 0.217710E+09 |
December | 48614241.33 | 0.00 | 48614241.33 | 10040593.41 | 0.310788E+09 |
Annual Sum or Average | 0.100639E+10 | 20181056.73 | 0.986211E+09 | 0.147121E+10 | 0.181103E+10 |
Minimum of Months | 48614241.33 | 0.00 | 48614241.33 | 7695087.21 | 7430524.98 |
Maximum of Months | 0.126039E+09 | 8265554.72 | 0.117773E+09 | 0.281080E+09 | 0.392125E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_2_FLR_3_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.222627E+09 | 0.103516E+09 | 0.119111E+09 | 0.179077E+09 | 0.682016E+09 |
February | 0.230374E+09 | 0.107973E+09 | 0.122401E+09 | 0.242208E+09 | 0.498417E+09 |
March | 0.374198E+09 | 0.180474E+09 | 0.193725E+09 | 0.489040E+09 | 0.316309E+09 |
April | 0.408065E+09 | 0.186640E+09 | 0.221425E+09 | 0.619145E+09 | 0.225109E+09 |
May | 0.424277E+09 | 0.161030E+09 | 0.263246E+09 | 0.716549E+09 | 0.129114E+09 |
June | 0.431370E+09 | 0.166096E+09 | 0.265273E+09 | 0.833809E+09 | 58280971.92 |
July | 0.419570E+09 | 0.155192E+09 | 0.264378E+09 | 0.855019E+09 | 28147687.02 |
August | 0.412124E+09 | 0.154141E+09 | 0.257983E+09 | 0.847926E+09 | 13832883.69 |
September | 0.325820E+09 | 0.136209E+09 | 0.189611E+09 | 0.578528E+09 | 85015835.68 |
October | 0.299566E+09 | 0.155754E+09 | 0.143812E+09 | 0.439068E+09 | 0.273382E+09 |
November | 0.230249E+09 | 0.102964E+09 | 0.127285E+09 | 0.277084E+09 | 0.396448E+09 |
December | 0.197060E+09 | 86321527.55 | 0.110739E+09 | 0.177806E+09 | 0.554737E+09 |
Annual Sum or Average | 0.397530E+10 | 0.169631E+10 | 0.227899E+10 | 0.625526E+10 | 0.326081E+10 |
Minimum of Months | 0.197060E+09 | 86321527.55 | 0.110739E+09 | 0.177806E+09 | 13832883.69 |
Maximum of Months | 0.431370E+09 | 0.186640E+09 | 0.265273E+09 | 0.855019E+09 | 0.682016E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.223330E+09 | 0.155141E+09 | 68188813.41 | 0.246514E+09 | 0.270746E+09 |
February | 0.187902E+09 | 0.125357E+09 | 62544840.67 | 0.226458E+09 | 0.207535E+09 |
March | 0.190235E+09 | 99826196.68 | 90408627.06 | 0.251956E+09 | 0.159024E+09 |
April | 0.138547E+09 | 46223853.60 | 92323562.43 | 0.209513E+09 | 0.120442E+09 |
May | 0.115082E+09 | 14083185.96 | 0.100999E+09 | 0.191440E+09 | 75158938.60 |
June | 0.102259E+09 | 5709065.05 | 96550134.41 | 0.209324E+09 | 38371673.03 |
July | 0.105998E+09 | 7149684.58 | 98847981.78 | 0.230701E+09 | 23447320.01 |
August | 0.127722E+09 | 24003960.40 | 0.103718E+09 | 0.277443E+09 | 16209306.97 |
September | 0.139546E+09 | 54295818.95 | 85250458.26 | 0.248705E+09 | 55194865.33 |
October | 0.202481E+09 | 0.130871E+09 | 71609428.64 | 0.300072E+09 | 0.140545E+09 |
November | 0.214083E+09 | 0.142858E+09 | 71225121.93 | 0.279020E+09 | 0.187011E+09 |
December | 0.221757E+09 | 0.155998E+09 | 65759141.47 | 0.260050E+09 | 0.237962E+09 |
Annual Sum or Average | 0.196894E+10 | 0.961517E+09 | 0.100743E+10 | 0.293120E+10 | 0.153165E+10 |
Minimum of Months | 0.102259E+09 | 5709065.05 | 62544840.67 | 0.191440E+09 | 16209306.97 |
Maximum of Months | 0.223330E+09 | 0.155998E+09 | 0.103718E+09 | 0.300072E+09 | 0.270746E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 42076451.99 | 0.00 | 42076451.99 | 5334960.77 | 0.330818E+09 |
February | 42124339.93 | 0.00 | 42124339.93 | 19102050.03 | 0.236992E+09 |
March | 65492691.15 | 1318.99 | 65491372.16 | 52442263.25 | 0.143356E+09 |
April | 76848851.72 | 448829.91 | 76400021.81 | 0.100770E+09 | 96654974.84 |
May | 94747450.04 | 2971603.27 | 91775846.77 | 0.159884E+09 | 50992190.01 |
June | 0.100844E+09 | 6613320.29 | 94230889.24 | 0.221632E+09 | 21128098.74 |
July | 98689421.90 | 5056973.36 | 93632448.53 | 0.235380E+09 | 10045407.66 |
August | 87654522.95 | 1029768.70 | 86624754.24 | 0.219043E+09 | 4421579.59 |
September | 64031230.67 | 25170.94 | 64006059.72 | 0.122506E+09 | 35146067.13 |
October | 50273499.29 | 0.00 | 50273499.29 | 55913344.89 | 0.122038E+09 |
November | 43541540.27 | 0.00 | 43541540.27 | 26433869.61 | 0.181935E+09 |
December | 38896548.34 | 0.00 | 38896548.34 | 6447731.02 | 0.264041E+09 |
Annual Sum or Average | 0.805221E+09 | 16146985.47 | 0.789074E+09 | 0.122489E+10 | 0.149757E+10 |
Minimum of Months | 38896548.34 | 0.00 | 38896548.34 | 5334960.77 | 4421579.59 |
Maximum of Months | 0.100844E+09 | 6613320.29 | 94230889.24 | 0.235380E+09 | 0.330818E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_5_FLR_3_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.217269E+09 | 98926312.94 | 0.118343E+09 | 0.142647E+09 | 0.672203E+09 |
February | 0.246295E+09 | 0.132584E+09 | 0.113711E+09 | 0.232354E+09 | 0.478502E+09 |
March | 0.343073E+09 | 0.156492E+09 | 0.186581E+09 | 0.400894E+09 | 0.299138E+09 |
April | 0.401332E+09 | 0.183183E+09 | 0.218149E+09 | 0.583294E+09 | 0.209542E+09 |
May | 0.454306E+09 | 0.192122E+09 | 0.262184E+09 | 0.751413E+09 | 0.119603E+09 |
June | 0.454739E+09 | 0.190467E+09 | 0.264272E+09 | 0.867798E+09 | 53006216.68 |
July | 0.458002E+09 | 0.192153E+09 | 0.265848E+09 | 0.916219E+09 | 27161513.49 |
August | 0.419782E+09 | 0.166515E+09 | 0.253266E+09 | 0.859161E+09 | 13363883.40 |
September | 0.332940E+09 | 0.147113E+09 | 0.185827E+09 | 0.582095E+09 | 82515429.61 |
October | 0.294256E+09 | 0.153163E+09 | 0.141093E+09 | 0.397308E+09 | 0.260639E+09 |
November | 0.226791E+09 | 0.102303E+09 | 0.124488E+09 | 0.227103E+09 | 0.374098E+09 |
December | 0.203367E+09 | 92572432.32 | 0.110794E+09 | 0.143995E+09 | 0.532203E+09 |
Annual Sum or Average | 0.405215E+10 | 0.180759E+10 | 0.224456E+10 | 0.610428E+10 | 0.312197E+10 |
Minimum of Months | 0.203367E+09 | 92572432.32 | 0.110794E+09 | 0.142647E+09 | 13363883.40 |
Maximum of Months | 0.458002E+09 | 0.192153E+09 | 0.265848E+09 | 0.916219E+09 | 0.672203E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_5_FLR_3_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.279218E+09 | 0.193965E+09 | 85252967.91 | 0.317210E+09 | 0.327077E+09 |
February | 0.234924E+09 | 0.156728E+09 | 78196598.94 | 0.290010E+09 | 0.243326E+09 |
March | 0.237841E+09 | 0.124808E+09 | 0.113033E+09 | 0.328269E+09 | 0.164986E+09 |
April | 0.173219E+09 | 57791307.85 | 0.115427E+09 | 0.271650E+09 | 0.122656E+09 |
May | 0.143881E+09 | 17607483.41 | 0.126274E+09 | 0.248249E+09 | 69704822.07 |
June | 0.127849E+09 | 7137750.53 | 0.120712E+09 | 0.271743E+09 | 31065109.05 |
July | 0.132523E+09 | 8938883.07 | 0.123585E+09 | 0.301107E+09 | 15064881.56 |
August | 0.159684E+09 | 30010917.68 | 0.129673E+09 | 0.361884E+09 | 7379568.06 |
September | 0.174468E+09 | 67883271.16 | 0.106584E+09 | 0.322444E+09 | 45813553.95 |
October | 0.253151E+09 | 0.163622E+09 | 89529587.28 | 0.387557E+09 | 0.140858E+09 |
November | 0.267657E+09 | 0.178608E+09 | 89049108.36 | 0.364791E+09 | 0.195991E+09 |
December | 0.277252E+09 | 0.195037E+09 | 82215273.99 | 0.339898E+09 | 0.267083E+09 |
Annual Sum or Average | 0.246167E+10 | 0.120214E+10 | 0.125953E+10 | 0.380481E+10 | 0.163101E+10 |
Minimum of Months | 0.127849E+09 | 7137750.53 | 78196598.94 | 0.248249E+09 | 7379568.06 |
Maximum of Months | 0.279218E+09 | 0.195037E+09 | 0.129673E+09 | 0.387557E+09 | 0.327077E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_6_FLR_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 52588594.07 | 0.00 | 52588594.07 | 7309927.43 | 0.392098E+09 |
February | 52648446.06 | 0.00 | 52648446.06 | 23599794.32 | 0.282916E+09 |
March | 81855013.60 | 1648.52 | 81853365.08 | 62732223.39 | 0.174763E+09 |
April | 96048332.89 | 560963.03 | 95487369.87 | 0.117857E+09 | 0.120653E+09 |
May | 0.118419E+09 | 3714011.78 | 0.114705E+09 | 0.188256E+09 | 65311108.79 |
June | 0.126039E+09 | 8265554.72 | 0.117773E+09 | 0.263063E+09 | 28677087.56 |
July | 0.123345E+09 | 6320378.90 | 0.117025E+09 | 0.279070E+09 | 14601641.94 |
August | 0.109554E+09 | 1287040.28 | 0.108267E+09 | 0.257899E+09 | 7140267.15 |
September | 80028430.11 | 31459.51 | 79996970.60 | 0.143027E+09 | 45502240.64 |
October | 62833545.17 | 0.00 | 62833545.17 | 65323884.10 | 0.148600E+09 |
November | 54419711.70 | 0.00 | 54419711.70 | 33517105.74 | 0.217291E+09 |
December | 48614241.33 | 0.00 | 48614241.33 | 9601594.08 | 0.310963E+09 |
Annual Sum or Average | 0.100639E+10 | 20181056.73 | 0.986211E+09 | 0.145126E+10 | 0.180852E+10 |
Minimum of Months | 48614241.33 | 0.00 | 48614241.33 | 7309927.43 | 7140267.15 |
Maximum of Months | 0.126039E+09 | 8265554.72 | 0.117773E+09 | 0.279070E+09 | 0.392098E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_6_FLR_3_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.217269E+09 | 98926312.94 | 0.118343E+09 | 0.147850E+09 | 0.656947E+09 |
February | 0.246295E+09 | 0.132584E+09 | 0.113711E+09 | 0.240240E+09 | 0.469301E+09 |
March | 0.343073E+09 | 0.156492E+09 | 0.186581E+09 | 0.411944E+09 | 0.292670E+09 |
April | 0.401332E+09 | 0.183183E+09 | 0.218149E+09 | 0.588604E+09 | 0.207224E+09 |
May | 0.454306E+09 | 0.192122E+09 | 0.262184E+09 | 0.753200E+09 | 0.118930E+09 |
June | 0.454739E+09 | 0.190467E+09 | 0.264272E+09 | 0.868131E+09 | 52934123.58 |
July | 0.458002E+09 | 0.192153E+09 | 0.265848E+09 | 0.916934E+09 | 27033901.54 |
August | 0.419782E+09 | 0.166515E+09 | 0.253266E+09 | 0.862113E+09 | 12975720.97 |
September | 0.332940E+09 | 0.147113E+09 | 0.185827E+09 | 0.586809E+09 | 80879081.37 |
October | 0.294256E+09 | 0.153163E+09 | 0.141093E+09 | 0.408176E+09 | 0.254363E+09 |
November | 0.226791E+09 | 0.102303E+09 | 0.124488E+09 | 0.239640E+09 | 0.363215E+09 |
December | 0.203367E+09 | 92572432.32 | 0.110794E+09 | 0.152081E+09 | 0.516514E+09 |
Annual Sum or Average | 0.405215E+10 | 0.180759E+10 | 0.224456E+10 | 0.617572E+10 | 0.305299E+10 |
Minimum of Months | 0.203367E+09 | 92572432.32 | 0.110794E+09 | 0.147850E+09 | 12975720.97 |
Maximum of Months | 0.458002E+09 | 0.192153E+09 | 0.265848E+09 | 0.916934E+09 | 0.656947E+09 |
Report: WindowEnergyReportMonthly
For: CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 66600136.23 | 0.00 | 66600136.23 | 8458502.91 | 0.537012E+09 |
February | 66675935.00 | 0.00 | 66675935.00 | 30747080.74 | 0.380910E+09 |
March | 0.103664E+09 | 2087.74 | 0.103662E+09 | 86779602.70 | 0.224919E+09 |
April | 0.121639E+09 | 710424.28 | 0.120929E+09 | 0.167969E+09 | 0.150788E+09 |
May | 0.149970E+09 | 4703561.58 | 0.145266E+09 | 0.265607E+09 | 79581307.77 |
June | 0.159620E+09 | 10467803.52 | 0.149152E+09 | 0.358707E+09 | 36125724.45 |
July | 0.156209E+09 | 8004361.08 | 0.148205E+09 | 0.375615E+09 | 19453753.39 |
August | 0.138743E+09 | 1629955.30 | 0.137113E+09 | 0.346229E+09 | 10322345.04 |
September | 0.101351E+09 | 39841.48 | 0.101311E+09 | 0.200205E+09 | 57805979.37 |
October | 79574720.39 | 0.00 | 79574720.39 | 92712596.96 | 0.191175E+09 |
November | 68919131.17 | 0.00 | 68919131.17 | 43273183.52 | 0.287754E+09 |
December | 61566869.25 | 0.00 | 61566869.25 | 9859227.65 | 0.424201E+09 |
Annual Sum or Average | 0.127453E+10 | 25558034.99 | 0.124897E+10 | 0.198616E+10 | 0.240005E+10 |
Minimum of Months | 61566869.25 | 0.00 | 61566869.25 | 8458502.91 | 10322345.04 |
Maximum of Months | 0.159620E+09 | 10467803.52 | 0.149152E+09 | 0.375615E+09 | 0.537012E+09 |
Report: WindowEnergyReportMonthly
For: CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 24551567.91 | 0.00 | 24551567.91 | 3118154.41 | 0.197965E+09 |
February | 24579510.47 | 0.00 | 24579510.47 | 11334647.10 | 0.140419E+09 |
March | 38214920.19 | 769.63 | 38214150.56 | 31990554.82 | 82914333.96 |
April | 44841228.59 | 261891.81 | 44579336.78 | 61920274.00 | 55586547.54 |
May | 55285042.92 | 1733927.56 | 53551115.36 | 97913821.88 | 29336965.25 |
June | 58842496.02 | 3858865.82 | 54983630.20 | 0.132234E+09 | 13317437.88 |
July | 57585179.58 | 2950738.93 | 54634440.65 | 0.138467E+09 | 7171459.02 |
August | 51146327.01 | 600869.02 | 50545457.99 | 0.127634E+09 | 3805243.80 |
September | 37362159.44 | 14687.22 | 37347472.22 | 73803754.76 | 21309677.55 |
October | 29334536.86 | 0.00 | 29334536.86 | 34177702.17 | 70475111.01 |
November | 25406445.47 | 0.00 | 25406445.47 | 15952287.25 | 0.106078E+09 |
December | 22696097.29 | 0.00 | 22696097.29 | 3634519.55 | 0.156378E+09 |
Annual Sum or Average | 0.469846E+09 | 9421749.97 | 0.460424E+09 | 0.732182E+09 | 0.884757E+09 |
Minimum of Months | 22696097.29 | 0.00 | 22696097.29 | 3118154.41 | 3805243.80 |
Maximum of Months | 58842496.02 | 3858865.82 | 54983630.20 | 0.138467E+09 | 0.197965E+09 |
Report: WindowEnergyReportMonthly
For: CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.130282E+09 | 90503082.87 | 39778691.28 | 0.146650E+09 | 0.160926E+09 |
February | 0.109615E+09 | 73128454.63 | 36486217.96 | 0.136544E+09 | 0.118397E+09 |
March | 0.110976E+09 | 58234705.39 | 52740862.99 | 0.158996E+09 | 77226582.98 |
April | 80823152.87 | 26965191.36 | 53857961.51 | 0.134927E+09 | 56027507.44 |
May | 67134435.80 | 8215580.81 | 58918854.99 | 0.126054E+09 | 31079746.35 |
June | 59654024.21 | 3330445.64 | 56323578.57 | 0.136151E+09 | 14377444.00 |
July | 61834899.83 | 4170846.82 | 57664053.01 | 0.148835E+09 | 7402513.03 |
August | 74508055.00 | 14002973.25 | 60505081.75 | 0.176673E+09 | 3837440.22 |
September | 81405849.48 | 31674060.78 | 49731788.71 | 0.158460E+09 | 21130534.94 |
October | 0.118119E+09 | 76345167.07 | 41774144.65 | 0.187559E+09 | 65771771.19 |
November | 0.124888E+09 | 83337782.51 | 41549955.12 | 0.173703E+09 | 93142187.10 |
December | 0.129365E+09 | 91003310.47 | 38361315.54 | 0.158531E+09 | 0.130218E+09 |
Annual Sum or Average | 0.114860E+10 | 0.560912E+09 | 0.587693E+09 | 0.184308E+10 | 0.779536E+09 |
Minimum of Months | 59654024.21 | 3330445.64 | 36486217.96 | 0.126054E+09 | 3837440.22 |
Maximum of Months | 0.130282E+09 | 91003310.47 | 60505081.75 | 0.187559E+09 | 0.160926E+09 |
Report: WindowEnergyReportMonthly
For: CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.353611E+09 | 0.245644E+09 | 0.107968E+09 | 0.398038E+09 | 0.436785E+09 |
February | 0.297517E+09 | 0.198486E+09 | 99031058.63 | 0.370607E+09 | 0.321354E+09 |
March | 0.301210E+09 | 0.158061E+09 | 0.143149E+09 | 0.431548E+09 | 0.209609E+09 |
April | 0.219371E+09 | 73189044.97 | 0.146182E+09 | 0.366220E+09 | 0.152070E+09 |
May | 0.182217E+09 | 22298766.77 | 0.159918E+09 | 0.342137E+09 | 84356788.82 |
June | 0.161913E+09 | 9039510.68 | 0.152874E+09 | 0.369543E+09 | 39023323.86 |
July | 0.167833E+09 | 11320531.40 | 0.156512E+09 | 0.403969E+09 | 20091934.53 |
August | 0.202230E+09 | 38006933.66 | 0.164223E+09 | 0.479527E+09 | 10415597.68 |
September | 0.220952E+09 | 85969879.73 | 0.134982E+09 | 0.430094E+09 | 57352593.97 |
October | 0.320600E+09 | 0.207216E+09 | 0.113384E+09 | 0.509073E+09 | 0.178518E+09 |
November | 0.338971E+09 | 0.226196E+09 | 0.112775E+09 | 0.471466E+09 | 0.252807E+09 |
December | 0.351122E+09 | 0.247002E+09 | 0.104120E+09 | 0.430285E+09 | 0.353438E+09 |
Annual Sum or Average | 0.311755E+10 | 0.152243E+10 | 0.159512E+10 | 0.500251E+10 | 0.211582E+10 |
Minimum of Months | 0.161913E+09 | 9039510.68 | 99031058.63 | 0.342137E+09 | 10415597.68 |
Maximum of Months | 0.353611E+09 | 0.247002E+09 | 0.164223E+09 | 0.509073E+09 | 0.436785E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_1_FLR_6_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.279218E+09 | 0.193965E+09 | 85252967.91 | 0.317580E+09 | 0.325655E+09 |
February | 0.234924E+09 | 0.156728E+09 | 78196598.94 | 0.290560E+09 | 0.242219E+09 |
March | 0.237841E+09 | 0.124808E+09 | 0.113033E+09 | 0.327005E+09 | 0.165280E+09 |
April | 0.173219E+09 | 57791307.85 | 0.115427E+09 | 0.269740E+09 | 0.123478E+09 |
May | 0.143881E+09 | 17607483.41 | 0.126274E+09 | 0.245534E+09 | 70610413.26 |
June | 0.127849E+09 | 7137750.53 | 0.120712E+09 | 0.269353E+09 | 31447039.23 |
July | 0.132523E+09 | 8938883.07 | 0.123585E+09 | 0.298099E+09 | 15278772.89 |
August | 0.159684E+09 | 30010917.68 | 0.129673E+09 | 0.357526E+09 | 7504184.22 |
September | 0.174468E+09 | 67883271.16 | 0.106584E+09 | 0.319272E+09 | 46206237.98 |
October | 0.253151E+09 | 0.163622E+09 | 89529587.28 | 0.385816E+09 | 0.140960E+09 |
November | 0.267657E+09 | 0.178608E+09 | 89049108.36 | 0.364291E+09 | 0.194900E+09 |
December | 0.277252E+09 | 0.195037E+09 | 82215273.99 | 0.340170E+09 | 0.265007E+09 |
Annual Sum or Average | 0.246167E+10 | 0.120214E+10 | 0.125953E+10 | 0.378495E+10 | 0.162855E+10 |
Minimum of Months | 0.127849E+09 | 7137750.53 | 78196598.94 | 0.245534E+09 | 7504184.22 |
Maximum of Months | 0.279218E+09 | 0.195037E+09 | 0.129673E+09 | 0.385816E+09 | 0.325655E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_1_FLR_6_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.222627E+09 | 0.103516E+09 | 0.119111E+09 | 0.169881E+09 | 0.688751E+09 |
February | 0.230374E+09 | 0.107973E+09 | 0.122401E+09 | 0.231379E+09 | 0.502837E+09 |
March | 0.374198E+09 | 0.180474E+09 | 0.193725E+09 | 0.470811E+09 | 0.320041E+09 |
April | 0.408065E+09 | 0.186640E+09 | 0.221425E+09 | 0.603028E+09 | 0.227214E+09 |
May | 0.424277E+09 | 0.161030E+09 | 0.263246E+09 | 0.702120E+09 | 0.130556E+09 |
June | 0.431370E+09 | 0.166096E+09 | 0.265273E+09 | 0.821509E+09 | 58128811.19 |
July | 0.419570E+09 | 0.155192E+09 | 0.264378E+09 | 0.842877E+09 | 28189519.68 |
August | 0.412124E+09 | 0.154141E+09 | 0.257983E+09 | 0.833495E+09 | 13958951.70 |
September | 0.325820E+09 | 0.136209E+09 | 0.189611E+09 | 0.564550E+09 | 86380963.73 |
October | 0.299566E+09 | 0.155754E+09 | 0.143812E+09 | 0.421064E+09 | 0.277626E+09 |
November | 0.230249E+09 | 0.102964E+09 | 0.127285E+09 | 0.261808E+09 | 0.402070E+09 |
December | 0.197060E+09 | 86321527.55 | 0.110739E+09 | 0.166466E+09 | 0.560891E+09 |
Annual Sum or Average | 0.397530E+10 | 0.169631E+10 | 0.227899E+10 | 0.608899E+10 | 0.329664E+10 |
Minimum of Months | 0.197060E+09 | 86321527.55 | 0.110739E+09 | 0.166466E+09 | 13958951.70 |
Maximum of Months | 0.431370E+09 | 0.186640E+09 | 0.265273E+09 | 0.842877E+09 | 0.688751E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_2_FLR_6_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 52588594.07 | 0.00 | 52588594.07 | 7948660.93 | 0.390329E+09 |
February | 52648446.06 | 0.00 | 52648446.06 | 24826940.19 | 0.280487E+09 |
March | 81855013.60 | 1648.52 | 81853365.08 | 63215271.87 | 0.173839E+09 |
April | 96048332.89 | 560963.03 | 95487369.87 | 0.117520E+09 | 0.121056E+09 |
May | 0.118419E+09 | 3714011.78 | 0.114705E+09 | 0.186315E+09 | 66294428.62 |
June | 0.126039E+09 | 8265554.72 | 0.117773E+09 | 0.260869E+09 | 29168342.04 |
July | 0.123345E+09 | 6320378.90 | 0.117025E+09 | 0.276237E+09 | 14864372.41 |
August | 0.109554E+09 | 1287040.28 | 0.108267E+09 | 0.254508E+09 | 7254286.04 |
September | 80028430.11 | 31459.51 | 79996970.60 | 0.141577E+09 | 45667225.62 |
October | 62833545.17 | 0.00 | 62833545.17 | 66404401.33 | 0.147756E+09 |
November | 54419711.70 | 0.00 | 54419711.70 | 34525036.83 | 0.215272E+09 |
December | 48614241.33 | 0.00 | 48614241.33 | 10733848.69 | 0.307616E+09 |
Annual Sum or Average | 0.100639E+10 | 20181056.73 | 0.986211E+09 | 0.144468E+10 | 0.179960E+10 |
Minimum of Months | 48614241.33 | 0.00 | 48614241.33 | 7948660.93 | 7254286.04 |
Maximum of Months | 0.126039E+09 | 8265554.72 | 0.117773E+09 | 0.276237E+09 | 0.390329E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_2_FLR_6_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.222627E+09 | 0.103516E+09 | 0.119111E+09 | 0.178593E+09 | 0.678853E+09 |
February | 0.230374E+09 | 0.107973E+09 | 0.122401E+09 | 0.240418E+09 | 0.495047E+09 |
March | 0.374198E+09 | 0.180474E+09 | 0.193725E+09 | 0.482788E+09 | 0.313467E+09 |
April | 0.408065E+09 | 0.186640E+09 | 0.221425E+09 | 0.609096E+09 | 0.224851E+09 |
May | 0.424277E+09 | 0.161030E+09 | 0.263246E+09 | 0.704052E+09 | 0.129838E+09 |
June | 0.431370E+09 | 0.166096E+09 | 0.265273E+09 | 0.821770E+09 | 58051116.57 |
July | 0.419570E+09 | 0.155192E+09 | 0.264378E+09 | 0.843515E+09 | 28047881.37 |
August | 0.412124E+09 | 0.154141E+09 | 0.257983E+09 | 0.836528E+09 | 13542584.22 |
September | 0.325820E+09 | 0.136209E+09 | 0.189611E+09 | 0.569797E+09 | 84536856.33 |
October | 0.299566E+09 | 0.155754E+09 | 0.143812E+09 | 0.433427E+09 | 0.270912E+09 |
November | 0.230249E+09 | 0.102964E+09 | 0.127285E+09 | 0.275797E+09 | 0.391882E+09 |
December | 0.197060E+09 | 86321527.55 | 0.110739E+09 | 0.178391E+09 | 0.549593E+09 |
Annual Sum or Average | 0.397530E+10 | 0.169631E+10 | 0.227899E+10 | 0.617417E+10 | 0.323862E+10 |
Minimum of Months | 0.197060E+09 | 86321527.55 | 0.110739E+09 | 0.178391E+09 | 13542584.22 |
Maximum of Months | 0.431370E+09 | 0.186640E+09 | 0.265273E+09 | 0.843515E+09 | 0.678853E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.409499E+09 | 0.284468E+09 | 0.125032E+09 | 0.443710E+09 | 0.499022E+09 |
February | 0.344539E+09 | 0.229856E+09 | 0.114683E+09 | 0.411232E+09 | 0.370489E+09 |
March | 0.348816E+09 | 0.183042E+09 | 0.165774E+09 | 0.470938E+09 | 0.248208E+09 |
April | 0.254042E+09 | 84756499.22 | 0.169285E+09 | 0.395422E+09 | 0.180428E+09 |
May | 0.211016E+09 | 25823064.22 | 0.185193E+09 | 0.366177E+09 | 0.100619E+09 |
June | 0.187503E+09 | 10468196.17 | 0.177035E+09 | 0.405500E+09 | 42826155.30 |
July | 0.194358E+09 | 13109729.90 | 0.181249E+09 | 0.448863E+09 | 20060345.06 |
August | 0.234192E+09 | 44013890.93 | 0.190178E+09 | 0.535207E+09 | 9377507.29 |
September | 0.255873E+09 | 99557331.94 | 0.156316E+09 | 0.470573E+09 | 66807785.69 |
October | 0.371270E+09 | 0.239967E+09 | 0.131304E+09 | 0.557997E+09 | 0.213129E+09 |
November | 0.392545E+09 | 0.261946E+09 | 0.130599E+09 | 0.519017E+09 | 0.299297E+09 |
December | 0.406617E+09 | 0.286040E+09 | 0.120577E+09 | 0.477148E+09 | 0.408882E+09 |
Annual Sum or Average | 0.361027E+10 | 0.176305E+10 | 0.184722E+10 | 0.550178E+10 | 0.245915E+10 |
Minimum of Months | 0.187503E+09 | 10468196.17 | 0.114683E+09 | 0.366177E+09 | 9377507.29 |
Maximum of Months | 0.409499E+09 | 0.286040E+09 | 0.190178E+09 | 0.557997E+09 | 0.499022E+09 |
Report: WindowEnergyReportMonthly
For: BANQUET_FLR_6_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.368106E+09 | 0.00 | 0.368106E+09 | 41089703.00 | 0.303607E+10 |
February | 0.368525E+09 | 0.00 | 0.368525E+09 | 0.156720E+09 | 0.218249E+10 |
March | 0.572963E+09 | 11539.19 | 0.572952E+09 | 0.438627E+09 | 0.133939E+10 |
April | 0.672313E+09 | 3926592.47 | 0.668386E+09 | 0.877728E+09 | 0.919102E+09 |
May | 0.828899E+09 | 25997097.83 | 0.802902E+09 | 0.140213E+10 | 0.525684E+09 |
June | 0.882236E+09 | 57856691.74 | 0.824380E+09 | 0.193624E+10 | 0.252164E+09 |
July | 0.863385E+09 | 44240976.70 | 0.819144E+09 | 0.204140E+10 | 0.145651E+09 |
August | 0.766846E+09 | 9008940.72 | 0.757837E+09 | 0.188768E+10 | 86647929.46 |
September | 0.560178E+09 | 220208.23 | 0.559958E+09 | 0.107748E+10 | 0.374574E+09 |
October | 0.439818E+09 | 0.00 | 0.439818E+09 | 0.481081E+09 | 0.114546E+10 |
November | 0.380924E+09 | 0.00 | 0.380924E+09 | 0.216803E+09 | 0.166972E+10 |
December | 0.340287E+09 | 0.00 | 0.340287E+09 | 45874640.42 | 0.242352E+10 |
Annual Sum or Average | 0.704448E+10 | 0.141262E+09 | 0.690322E+10 | 0.106029E+11 | 0.141005E+11 |
Minimum of Months | 0.340287E+09 | 0.00 | 0.340287E+09 | 41089703.00 | 86647929.46 |
Maximum of Months | 0.882236E+09 | 57856691.74 | 0.824380E+09 | 0.204140E+10 | 0.303607E+10 |
Report: WindowEnergyReportMonthly
For: DINING_FLR_6_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.368106E+09 | 0.00 | 0.368106E+09 | 38795070.93 | 0.308612E+10 |
February | 0.368525E+09 | 0.00 | 0.368525E+09 | 0.150856E+09 | 0.222587E+10 |
March | 0.572963E+09 | 11539.19 | 0.572952E+09 | 0.422183E+09 | 0.137941E+10 |
April | 0.672313E+09 | 3926592.47 | 0.668386E+09 | 0.854690E+09 | 0.951570E+09 |
May | 0.828899E+09 | 25997097.83 | 0.802902E+09 | 0.137100E+10 | 0.553806E+09 |
June | 0.882236E+09 | 57856691.74 | 0.824380E+09 | 0.189907E+10 | 0.272158E+09 |
July | 0.863385E+09 | 44240976.70 | 0.819144E+09 | 0.200244E+10 | 0.161680E+09 |
August | 0.766846E+09 | 9008940.72 | 0.757837E+09 | 0.184843E+10 | 0.101289E+09 |
September | 0.560178E+09 | 220208.23 | 0.559958E+09 | 0.104876E+10 | 0.401400E+09 |
October | 0.439818E+09 | 0.00 | 0.439818E+09 | 0.464986E+09 | 0.118483E+10 |
November | 0.380924E+09 | 0.00 | 0.380924E+09 | 0.206314E+09 | 0.171143E+10 |
December | 0.340287E+09 | 0.00 | 0.340287E+09 | 42166387.22 | 0.247333E+10 |
Annual Sum or Average | 0.704448E+10 | 0.141262E+09 | 0.690322E+10 | 0.103497E+11 | 0.145029E+11 |
Minimum of Months | 0.340287E+09 | 0.00 | 0.340287E+09 | 38795070.93 | 0.101289E+09 |
Maximum of Months | 0.882236E+09 | 57856691.74 | 0.824380E+09 | 0.200244E+10 | 0.308612E+10 |
Report: WindowEnergyReportMonthly
For: KITCHEN_FLR_6_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 52588594.07 | 0.00 | 52588594.07 | 6645186.27 | 0.433930E+09 |
February | 52648446.06 | 0.00 | 52648446.06 | 23280509.90 | 0.316493E+09 |
March | 81855013.60 | 1648.52 | 81853365.08 | 66196258.16 | 0.199751E+09 |
April | 96048332.89 | 560963.03 | 95487369.87 | 0.133413E+09 | 0.137606E+09 |
May | 0.118419E+09 | 3714011.78 | 0.114705E+09 | 0.213874E+09 | 82068337.39 |
June | 0.126039E+09 | 8265554.72 | 0.117773E+09 | 0.291115E+09 | 41345993.31 |
July | 0.123345E+09 | 6320378.90 | 0.117025E+09 | 0.309927E+09 | 23975904.25 |
August | 0.109554E+09 | 1287040.28 | 0.108267E+09 | 0.287103E+09 | 15310333.15 |
September | 80028430.11 | 31459.51 | 79996970.60 | 0.164859E+09 | 57415753.98 |
October | 62833545.17 | 0.00 | 62833545.17 | 73571118.29 | 0.170201E+09 |
November | 54419711.70 | 0.00 | 54419711.70 | 34725959.78 | 0.243954E+09 |
December | 48614241.33 | 0.00 | 48614241.33 | 7589712.75 | 0.350348E+09 |
Annual Sum or Average | 0.100639E+10 | 20181056.73 | 0.986211E+09 | 0.161230E+10 | 0.207240E+10 |
Minimum of Months | 48614241.33 | 0.00 | 48614241.33 | 6645186.27 | 15310333.15 |
Maximum of Months | 0.126039E+09 | 8265554.72 | 0.117773E+09 | 0.309927E+09 | 0.433930E+09 |
Report: WindowEnergyReportMonthly
For: KITCHEN_FLR_6_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.434507E+09 | 0.197839E+09 | 0.236668E+09 | 0.289497E+09 | 0.146058E+10 |
February | 0.492555E+09 | 0.265149E+09 | 0.227406E+09 | 0.479777E+09 | 0.106160E+10 |
March | 0.686097E+09 | 0.312962E+09 | 0.373136E+09 | 0.845077E+09 | 0.681368E+09 |
April | 0.802608E+09 | 0.366340E+09 | 0.436268E+09 | 0.124521E+10 | 0.484443E+09 |
May | 0.908547E+09 | 0.384217E+09 | 0.524331E+09 | 0.160448E+10 | 0.304279E+09 |
June | 0.909412E+09 | 0.380907E+09 | 0.528506E+09 | 0.184577E+10 | 0.154526E+09 |
July | 0.915938E+09 | 0.384279E+09 | 0.531659E+09 | 0.194528E+10 | 90647886.23 |
August | 0.839504E+09 | 0.333007E+09 | 0.506497E+09 | 0.182792E+10 | 57843840.32 |
September | 0.665833E+09 | 0.294206E+09 | 0.371628E+09 | 0.125973E+10 | 0.210486E+09 |
October | 0.588469E+09 | 0.306304E+09 | 0.282165E+09 | 0.856256E+09 | 0.592415E+09 |
November | 0.453550E+09 | 0.204592E+09 | 0.248958E+09 | 0.489097E+09 | 0.821130E+09 |
December | 0.406705E+09 | 0.185132E+09 | 0.221573E+09 | 0.294785E+09 | 0.117040E+10 |
Annual Sum or Average | 0.810373E+10 | 0.361493E+10 | 0.448879E+10 | 0.129829E+11 | 0.708971E+10 |
Minimum of Months | 0.406705E+09 | 0.185132E+09 | 0.221573E+09 | 0.289497E+09 | 57843840.32 |
Maximum of Months | 0.915938E+09 | 0.384279E+09 | 0.531659E+09 | 0.194528E+10 | 0.146058E+10 |
Report: WindowEnergyReportMonthly
For: KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.279218E+09 | 0.193965E+09 | 85252967.91 | 0.318295E+09 | 0.353701E+09 |
February | 0.234924E+09 | 0.156728E+09 | 78196598.94 | 0.293968E+09 | 0.267967E+09 |
March | 0.237841E+09 | 0.124808E+09 | 0.113033E+09 | 0.340280E+09 | 0.186139E+09 |
April | 0.173219E+09 | 57791307.85 | 0.115427E+09 | 0.290802E+09 | 0.138309E+09 |
May | 0.143881E+09 | 17607483.41 | 0.126274E+09 | 0.274856E+09 | 85015884.02 |
June | 0.127849E+09 | 7137750.53 | 0.120712E+09 | 0.300323E+09 | 43150341.50 |
July | 0.132523E+09 | 8938883.07 | 0.123585E+09 | 0.331576E+09 | 24229016.33 |
August | 0.159684E+09 | 30010917.68 | 0.129673E+09 | 0.392178E+09 | 15327614.93 |
September | 0.174468E+09 | 67883271.16 | 0.106584E+09 | 0.348528E+09 | 56589492.29 |
October | 0.253151E+09 | 0.163622E+09 | 89529587.28 | 0.405496E+09 | 0.158855E+09 |
November | 0.267657E+09 | 0.178608E+09 | 89049108.36 | 0.377211E+09 | 0.215028E+09 |
December | 0.277252E+09 | 0.195037E+09 | 82215273.99 | 0.343468E+09 | 0.292832E+09 |
Annual Sum or Average | 0.246167E+10 | 0.120214E+10 | 0.125953E+10 | 0.401698E+10 | 0.183714E+10 |
Minimum of Months | 0.127849E+09 | 7137750.53 | 78196598.94 | 0.274856E+09 | 15327614.93 |
Maximum of Months | 0.279218E+09 | 0.195037E+09 | 0.129673E+09 | 0.405496E+09 | 0.353701E+09 |
Report: WindowEnergyReportMonthly
For: CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 66600136.23 | 0.00 | 66600136.23 | 7859228.26 | 0.542829E+09 |
February | 66675935.00 | 0.00 | 66675935.00 | 29037591.22 | 0.385168E+09 |
March | 0.103664E+09 | 2087.74 | 0.103662E+09 | 81803225.99 | 0.228234E+09 |
April | 0.121639E+09 | 710424.28 | 0.120929E+09 | 0.161566E+09 | 0.152174E+09 |
May | 0.149970E+09 | 4703561.58 | 0.145266E+09 | 0.258407E+09 | 79620501.60 |
June | 0.159620E+09 | 10467803.52 | 0.149152E+09 | 0.357009E+09 | 33455204.86 |
July | 0.156209E+09 | 8004361.08 | 0.148205E+09 | 0.374330E+09 | 16926195.08 |
August | 0.138743E+09 | 1629955.30 | 0.137113E+09 | 0.346779E+09 | 7883414.27 |
September | 0.101351E+09 | 39841.48 | 0.101311E+09 | 0.198991E+09 | 54697915.46 |
October | 79574720.39 | 0.00 | 79574720.39 | 88412182.37 | 0.193549E+09 |
November | 68919131.17 | 0.00 | 68919131.17 | 40264223.22 | 0.291674E+09 |
December | 61566869.25 | 0.00 | 61566869.25 | 8781409.22 | 0.429484E+09 |
Annual Sum or Average | 0.127453E+10 | 25558034.99 | 0.124897E+10 | 0.195324E+10 | 0.241569E+10 |
Minimum of Months | 61566869.25 | 0.00 | 61566869.25 | 7859228.26 | 7883414.27 |
Maximum of Months | 0.159620E+09 | 10467803.52 | 0.149152E+09 | 0.374330E+09 | 0.542829E+09 |
Report: WindowEnergyReportMonthly
For: CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 59587394.23 | 0.00 | 59587394.23 | 7031681.30 | 0.485662E+09 |
February | 59655211.68 | 0.00 | 59655211.68 | 25980042.89 | 0.344612E+09 |
March | 92748761.43 | 1867.91 | 92746893.52 | 73189656.25 | 0.204202E+09 |
April | 0.108831E+09 | 635619.29 | 0.108195E+09 | 0.144554E+09 | 0.136150E+09 |
May | 0.134178E+09 | 4208294.36 | 0.129970E+09 | 0.231198E+09 | 71236764.46 |
June | 0.142813E+09 | 9365583.47 | 0.133447E+09 | 0.319418E+09 | 29932498.55 |
July | 0.139761E+09 | 7161532.19 | 0.132599E+09 | 0.334915E+09 | 15143930.88 |
August | 0.124134E+09 | 1458327.18 | 0.122675E+09 | 0.310264E+09 | 7053320.62 |
September | 90679085.44 | 35646.33 | 90643439.12 | 0.178038E+09 | 48938432.21 |
October | 71195803.84 | 0.00 | 71195803.84 | 79102714.56 | 0.173169E+09 |
November | 61662207.79 | 0.00 | 61662207.79 | 36024553.08 | 0.260959E+09 |
December | 55084111.20 | 0.00 | 55084111.20 | 7856760.10 | 0.384246E+09 |
Annual Sum or Average | 0.114033E+10 | 22866870.75 | 0.111746E+10 | 0.174757E+10 | 0.216131E+10 |
Minimum of Months | 55084111.20 | 0.00 | 55084111.20 | 7031681.30 | 7053320.62 |
Maximum of Months | 0.142813E+09 | 9365583.47 | 0.133447E+09 | 0.334915E+09 | 0.485662E+09 |
Report: WindowEnergyReportMonthly
For: CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.104240E+10 | 0.724128E+09 | 0.318275E+09 | 0.115419E+10 | 0.129547E+10 |
February | 0.877042E+09 | 0.585111E+09 | 0.291931E+09 | 0.107412E+10 | 0.956374E+09 |
March | 0.887931E+09 | 0.465944E+09 | 0.421987E+09 | 0.124561E+10 | 0.626149E+09 |
April | 0.646677E+09 | 0.215752E+09 | 0.430925E+09 | 0.105447E+10 | 0.453035E+09 |
May | 0.537152E+09 | 65733982.34 | 0.471418E+09 | 0.984664E+09 | 0.249622E+09 |
June | 0.477300E+09 | 26647349.68 | 0.450653E+09 | 0.108249E+10 | 0.107235E+09 |
July | 0.494749E+09 | 33371514.17 | 0.461378E+09 | 0.118529E+10 | 51544602.26 |
August | 0.596149E+09 | 0.112040E+09 | 0.484109E+09 | 0.141139E+10 | 23712772.92 |
September | 0.651339E+09 | 0.253428E+09 | 0.397911E+09 | 0.125866E+10 | 0.160811E+09 |
October | 0.945089E+09 | 0.610848E+09 | 0.334241E+09 | 0.147660E+10 | 0.532395E+09 |
November | 0.999244E+09 | 0.666797E+09 | 0.332447E+09 | 0.136870E+10 | 0.753484E+09 |
December | 0.103506E+10 | 0.728130E+09 | 0.306934E+09 | 0.124782E+10 | 0.105089E+10 |
Annual Sum or Average | 0.919014E+10 | 0.448793E+10 | 0.470221E+10 | 0.145440E+11 | 0.626072E+10 |
Minimum of Months | 0.477300E+09 | 26647349.68 | 0.291931E+09 | 0.984664E+09 | 23712772.92 |
Maximum of Months | 0.104240E+10 | 0.728130E+09 | 0.484109E+09 | 0.147660E+10 | 0.129547E+10 |
Report: WindowZoneSummaryMonthly
For: BASEMENT
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: RETAIL_1_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 603.20 | 598.69 | 527.26 | 366.27 | 160.99 | 0.00 | 0.00 |
February | 617.12 | 491.74 | 491.15 | 327.66 | 163.48 | 0.00 | 0.00 |
March | 640.33 | 301.24 | 449.12 | 235.68 | 213.44 | 0.00 | 0.00 |
April | 553.71 | 228.07 | 338.00 | 112.77 | 225.23 | 0.00 | 0.00 |
May | 494.79 | 124.87 | 271.69 | 33.25 | 238.45 | 0.00 | 0.00 |
June | 552.68 | 58.39 | 249.47 | 13.93 | 235.54 | 0.00 | 0.00 |
July | 587.33 | 27.24 | 250.25 | 16.88 | 233.37 | 0.00 | 0.00 |
August | 697.30 | 14.49 | 301.54 | 56.67 | 244.87 | 0.00 | 0.00 |
September | 646.87 | 86.91 | 340.43 | 132.46 | 207.97 | 0.00 | 0.00 |
October | 746.96 | 259.10 | 478.03 | 308.97 | 169.06 | 0.00 | 0.00 |
November | 721.48 | 372.82 | 522.27 | 348.52 | 173.76 | 0.00 | 0.00 |
December | 647.97 | 490.95 | 523.54 | 368.30 | 155.25 | 0.00 | 0.00 |
Annual Sum or Average | 625.96 | 253.34 | 394.80 | 192.80 | 202.00 | 0.00 | 0.00 |
Minimum of Months | 494.79 | 14.49 | 249.47 | 13.93 | 155.25 | 0.00 | 0.00 |
Maximum of Months | 746.96 | 598.69 | 527.26 | 368.30 | 244.87 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: RETAIL_2_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: MECH_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: STORAGE_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: LAUNDRY_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CAFE_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1680.96 | 1708.07 | 1484.72 | 1031.40 | 453.32 | 0.00 | 0.00 |
February | 1722.00 | 1406.78 | 1383.03 | 922.68 | 460.35 | 0.00 | 0.00 |
March | 1788.59 | 863.18 | 1264.70 | 663.66 | 601.04 | 0.00 | 0.00 |
April | 1547.13 | 654.34 | 951.78 | 317.55 | 634.23 | 0.00 | 0.00 |
May | 1380.92 | 367.60 | 765.07 | 93.63 | 671.45 | 0.00 | 0.00 |
June | 1541.93 | 182.56 | 702.49 | 39.22 | 663.27 | 0.00 | 0.00 |
July | 1640.65 | 93.35 | 704.68 | 47.53 | 657.15 | 0.00 | 0.00 |
August | 1948.93 | 56.92 | 849.11 | 159.58 | 689.52 | 0.00 | 0.00 |
September | 1810.71 | 264.54 | 958.64 | 373.00 | 585.64 | 0.00 | 0.00 |
October | 2092.32 | 747.11 | 1346.11 | 870.05 | 476.06 | 0.00 | 0.00 |
November | 2016.91 | 1063.89 | 1470.69 | 981.40 | 489.29 | 0.00 | 0.00 |
December | 1807.37 | 1401.30 | 1474.27 | 1037.10 | 437.17 | 0.00 | 0.00 |
Annual Sum or Average | 1748.63 | 730.72 | 1111.73 | 542.91 | 568.82 | 0.00 | 0.00 |
Minimum of Months | 1380.92 | 56.92 | 702.49 | 39.22 | 437.17 | 0.00 | 0.00 |
Maximum of Months | 2092.32 | 1708.07 | 1484.72 | 1037.10 | 689.52 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: LOBBY_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 2217.00 | 2287.38 | 1928.74 | 1339.84 | 588.89 | 0.00 | 0.00 |
February | 2278.10 | 1880.32 | 1796.64 | 1198.62 | 598.02 | 0.00 | 0.00 |
March | 2376.40 | 1149.69 | 1642.92 | 862.13 | 780.79 | 0.00 | 0.00 |
April | 2062.90 | 874.25 | 1236.41 | 412.51 | 823.90 | 0.00 | 0.00 |
May | 1847.11 | 492.44 | 993.87 | 121.63 | 872.25 | 0.00 | 0.00 |
June | 2065.28 | 242.25 | 912.57 | 50.95 | 861.62 | 0.00 | 0.00 |
July | 2199.92 | 121.71 | 915.42 | 61.75 | 853.67 | 0.00 | 0.00 |
August | 2616.85 | 69.48 | 1103.04 | 207.31 | 895.73 | 0.00 | 0.00 |
September | 2420.96 | 347.04 | 1245.33 | 484.54 | 760.78 | 0.00 | 0.00 |
October | 2784.38 | 989.75 | 1748.68 | 1130.24 | 618.43 | 0.00 | 0.00 |
November | 2675.24 | 1415.61 | 1910.51 | 1274.89 | 635.62 | 0.00 | 0.00 |
December | 2387.43 | 1871.72 | 1915.16 | 1347.25 | 567.91 | 0.00 | 0.00 |
Annual Sum or Average | 2328.27 | 973.89 | 1444.20 | 705.27 | 738.93 | 0.00 | 0.00 |
Minimum of Months | 1847.11 | 69.48 | 912.57 | 50.95 | 567.91 | 0.00 | 0.00 |
Maximum of Months | 2784.38 | 2287.38 | 1928.74 | 1347.25 | 895.73 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_1_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 163.75 | 362.39 | 187.37 | 111.07 | 76.30 | 0.00 | 0.00 |
February | 203.40 | 296.15 | 192.34 | 109.42 | 82.92 | 0.00 | 0.00 |
March | 298.24 | 178.76 | 228.51 | 113.98 | 114.53 | 0.00 | 0.00 |
April | 341.13 | 134.09 | 224.26 | 94.30 | 129.96 | 0.00 | 0.00 |
May | 360.31 | 74.48 | 212.13 | 66.70 | 145.43 | 0.00 | 0.00 |
June | 427.27 | 34.64 | 215.75 | 66.83 | 148.91 | 0.00 | 0.00 |
July | 432.13 | 16.27 | 206.13 | 61.28 | 144.85 | 0.00 | 0.00 |
August | 450.92 | 8.18 | 213.49 | 68.75 | 144.73 | 0.00 | 0.00 |
September | 345.96 | 51.23 | 193.01 | 78.74 | 114.27 | 0.00 | 0.00 |
October | 302.16 | 154.40 | 206.36 | 119.24 | 87.12 | 0.00 | 0.00 |
November | 235.21 | 224.49 | 192.09 | 108.63 | 83.46 | 0.00 | 0.00 |
December | 174.20 | 296.07 | 177.09 | 105.05 | 72.04 | 0.00 | 0.00 |
Annual Sum or Average | 311.82 | 151.87 | 204.11 | 91.91 | 112.21 | 0.00 | 0.00 |
Minimum of Months | 163.75 | 8.18 | 177.09 | 61.28 | 72.04 | 0.00 | 0.00 |
Maximum of Months | 450.92 | 362.39 | 228.51 | 119.24 | 148.91 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_2_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 61.77 | 393.08 | 102.75 | 38.65 | 64.11 | 0.00 | 0.00 |
February | 104.85 | 317.20 | 116.99 | 44.63 | 72.36 | 0.00 | 0.00 |
March | 204.93 | 181.79 | 170.27 | 67.38 | 102.89 | 0.00 | 0.00 |
April | 284.69 | 132.78 | 194.49 | 72.22 | 122.27 | 0.00 | 0.00 |
May | 338.49 | 72.26 | 202.62 | 61.51 | 141.11 | 0.00 | 0.00 |
June | 423.46 | 33.09 | 215.05 | 67.27 | 147.78 | 0.00 | 0.00 |
July | 423.96 | 15.83 | 202.70 | 60.30 | 142.40 | 0.00 | 0.00 |
August | 413.26 | 7.92 | 194.77 | 58.03 | 136.74 | 0.00 | 0.00 |
September | 279.02 | 50.44 | 156.58 | 52.56 | 104.02 | 0.00 | 0.00 |
October | 188.29 | 156.76 | 135.30 | 58.15 | 77.15 | 0.00 | 0.00 |
November | 118.46 | 235.32 | 109.83 | 39.72 | 70.10 | 0.00 | 0.00 |
December | 66.18 | 319.19 | 91.72 | 32.23 | 59.50 | 0.00 | 0.00 |
Annual Sum or Average | 243.03 | 158.86 | 157.97 | 54.43 | 103.54 | 0.00 | 0.00 |
Minimum of Months | 61.77 | 7.92 | 91.72 | 32.23 | 59.50 | 0.00 | 0.00 |
Maximum of Months | 423.96 | 393.08 | 215.05 | 72.22 | 147.78 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 92.04 | 101.08 | 83.38 | 57.92 | 25.46 | 0.00 | 0.00 |
February | 93.61 | 85.79 | 77.67 | 51.82 | 25.85 | 0.00 | 0.00 |
March | 94.07 | 59.37 | 71.03 | 37.27 | 33.75 | 0.00 | 0.00 |
April | 80.83 | 46.47 | 53.45 | 17.83 | 35.62 | 0.00 | 0.00 |
May | 71.48 | 28.06 | 42.97 | 5.26 | 37.71 | 0.00 | 0.00 |
June | 80.76 | 14.80 | 39.45 | 2.20 | 37.25 | 0.00 | 0.00 |
July | 86.13 | 8.75 | 39.57 | 2.67 | 36.91 | 0.00 | 0.00 |
August | 103.59 | 6.05 | 47.69 | 8.96 | 38.72 | 0.00 | 0.00 |
September | 95.95 | 21.29 | 53.84 | 20.95 | 32.89 | 0.00 | 0.00 |
October | 112.03 | 52.47 | 75.60 | 48.86 | 26.74 | 0.00 | 0.00 |
November | 107.65 | 72.15 | 82.59 | 55.11 | 27.48 | 0.00 | 0.00 |
December | 97.09 | 88.84 | 82.79 | 58.24 | 24.55 | 0.00 | 0.00 |
Annual Sum or Average | 92.95 | 48.57 | 62.43 | 30.49 | 31.95 | 0.00 | 0.00 |
Minimum of Months | 71.48 | 6.05 | 39.45 | 2.20 | 24.55 | 0.00 | 0.00 |
Maximum of Months | 112.03 | 101.08 | 83.38 | 58.24 | 38.72 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1.99 | 123.51 | 15.71 | 0.00 | 15.71 | 0.00 | 0.00 |
February | 7.90 | 97.96 | 17.41 | 0.00 | 17.41 | 0.00 | 0.00 |
March | 19.58 | 53.52 | 24.45 | 0.00 | 24.45 | 0.00 | 0.00 |
April | 38.88 | 37.29 | 29.65 | 0.17 | 29.48 | 0.00 | 0.00 |
May | 59.69 | 19.04 | 35.37 | 1.11 | 34.27 | 0.00 | 0.00 |
June | 85.51 | 8.15 | 38.91 | 2.55 | 36.35 | 0.00 | 0.00 |
July | 87.88 | 3.75 | 36.85 | 1.89 | 34.96 | 0.00 | 0.00 |
August | 81.78 | 1.65 | 32.73 | 0.38 | 32.34 | 0.00 | 0.00 |
September | 47.26 | 13.56 | 24.70 | 0.01 | 24.69 | 0.00 | 0.00 |
October | 20.88 | 45.56 | 18.77 | 0.00 | 18.77 | 0.00 | 0.00 |
November | 10.20 | 70.19 | 16.80 | 0.00 | 16.80 | 0.00 | 0.00 |
December | 2.41 | 98.58 | 14.52 | 0.00 | 14.52 | 0.00 | 0.00 |
Annual Sum or Average | 38.84 | 47.49 | 25.53 | 0.51 | 25.02 | 0.00 | 0.00 |
Minimum of Months | 1.99 | 1.65 | 14.52 | 0.00 | 14.52 | 0.00 | 0.00 |
Maximum of Months | 87.88 | 123.51 | 38.91 | 2.55 | 36.35 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_5_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 155.72 | 357.11 | 185.37 | 109.35 | 76.01 | 0.00 | 0.00 |
February | 207.01 | 289.46 | 198.92 | 119.59 | 79.33 | 0.00 | 0.00 |
March | 269.18 | 170.22 | 216.89 | 105.03 | 111.86 | 0.00 | 0.00 |
April | 326.32 | 124.65 | 221.66 | 92.97 | 128.69 | 0.00 | 0.00 |
May | 371.50 | 68.95 | 223.34 | 78.30 | 145.03 | 0.00 | 0.00 |
June | 438.74 | 31.54 | 224.76 | 76.24 | 148.53 | 0.00 | 0.00 |
July | 454.34 | 15.61 | 220.48 | 75.08 | 145.40 | 0.00 | 0.00 |
August | 455.83 | 7.69 | 216.35 | 73.37 | 142.97 | 0.00 | 0.00 |
September | 348.43 | 48.97 | 195.76 | 82.95 | 112.81 | 0.00 | 0.00 |
October | 291.30 | 148.16 | 204.38 | 118.27 | 86.10 | 0.00 | 0.00 |
November | 225.26 | 216.84 | 190.76 | 108.38 | 82.38 | 0.00 | 0.00 |
December | 171.63 | 289.39 | 179.44 | 107.38 | 72.06 | 0.00 | 0.00 |
Annual Sum or Average | 310.17 | 146.67 | 206.55 | 95.44 | 111.11 | 0.00 | 0.00 |
Minimum of Months | 155.72 | 7.69 | 179.44 | 73.37 | 72.06 | 0.00 | 0.00 |
Maximum of Months | 455.83 | 357.11 | 224.76 | 119.59 | 148.53 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_6_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 46.62 | 380.36 | 100.75 | 36.93 | 63.82 | 0.00 | 0.00 |
February | 98.00 | 299.87 | 123.57 | 54.80 | 68.77 | 0.00 | 0.00 |
March | 171.49 | 168.78 | 158.65 | 58.43 | 100.22 | 0.00 | 0.00 |
April | 269.10 | 123.04 | 191.89 | 70.89 | 121.00 | 0.00 | 0.00 |
May | 350.90 | 68.19 | 213.83 | 73.12 | 140.71 | 0.00 | 0.00 |
June | 436.32 | 31.39 | 224.07 | 76.67 | 147.39 | 0.00 | 0.00 |
July | 446.53 | 15.54 | 217.05 | 74.10 | 142.95 | 0.00 | 0.00 |
August | 418.16 | 7.50 | 197.63 | 62.65 | 134.98 | 0.00 | 0.00 |
September | 280.91 | 48.10 | 159.32 | 56.77 | 102.56 | 0.00 | 0.00 |
October | 172.59 | 146.25 | 133.32 | 57.18 | 76.14 | 0.00 | 0.00 |
November | 98.44 | 217.02 | 108.49 | 39.47 | 69.02 | 0.00 | 0.00 |
December | 50.27 | 298.85 | 94.08 | 34.56 | 59.52 | 0.00 | 0.00 |
Annual Sum or Average | 237.37 | 149.68 | 160.41 | 57.96 | 102.45 | 0.00 | 0.00 |
Minimum of Months | 46.62 | 7.50 | 94.08 | 34.56 | 59.52 | 0.00 | 0.00 |
Maximum of Months | 446.53 | 380.36 | 224.07 | 76.67 | 147.39 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORRIDOR_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 173.39 | 463.27 | 214.70 | 125.50 | 89.19 | 0.00 | 0.00 |
February | 205.03 | 375.27 | 206.01 | 112.27 | 93.74 | 0.00 | 0.00 |
March | 261.10 | 218.29 | 206.86 | 80.76 | 126.11 | 0.00 | 0.00 |
April | 281.65 | 159.52 | 180.04 | 39.01 | 141.03 | 0.00 | 0.00 |
May | 309.89 | 83.13 | 169.73 | 13.80 | 155.93 | 0.00 | 0.00 |
June | 383.70 | 38.87 | 169.76 | 10.30 | 159.46 | 0.00 | 0.00 |
July | 398.06 | 19.93 | 165.57 | 9.87 | 155.70 | 0.00 | 0.00 |
August | 421.88 | 10.56 | 174.22 | 20.25 | 153.97 | 0.00 | 0.00 |
September | 332.71 | 60.74 | 170.17 | 45.41 | 124.76 | 0.00 | 0.00 |
October | 303.99 | 185.42 | 204.46 | 105.87 | 98.59 | 0.00 | 0.00 |
November | 260.62 | 274.27 | 215.35 | 119.42 | 95.93 | 0.00 | 0.00 |
December | 200.85 | 373.32 | 210.85 | 126.20 | 84.66 | 0.00 | 0.00 |
Annual Sum or Average | 294.92 | 187.62 | 190.59 | 67.17 | 123.42 | 0.00 | 0.00 |
Minimum of Months | 173.39 | 10.56 | 165.57 | 9.87 | 84.66 | 0.00 | 0.00 |
Maximum of Months | 421.88 | 463.27 | 215.35 | 126.20 | 159.46 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_1_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 163.55 | 360.29 | 187.37 | 111.07 | 76.30 | 0.00 | 0.00 |
February | 202.02 | 294.24 | 192.34 | 109.42 | 82.92 | 0.00 | 0.00 |
March | 294.19 | 177.52 | 228.51 | 113.98 | 114.53 | 0.00 | 0.00 |
April | 335.40 | 133.98 | 224.26 | 94.30 | 129.96 | 0.00 | 0.00 |
May | 353.61 | 74.91 | 212.13 | 66.70 | 145.43 | 0.00 | 0.00 |
June | 420.83 | 34.53 | 215.75 | 66.83 | 148.91 | 0.00 | 0.00 |
July | 425.98 | 16.22 | 206.13 | 61.28 | 144.85 | 0.00 | 0.00 |
August | 444.68 | 8.01 | 213.49 | 68.75 | 144.73 | 0.00 | 0.00 |
September | 340.86 | 51.03 | 193.01 | 78.74 | 114.27 | 0.00 | 0.00 |
October | 298.33 | 153.36 | 206.36 | 119.24 | 87.12 | 0.00 | 0.00 |
November | 233.68 | 222.44 | 192.09 | 108.63 | 83.46 | 0.00 | 0.00 |
December | 174.09 | 293.29 | 177.09 | 105.05 | 72.04 | 0.00 | 0.00 |
Annual Sum or Average | 307.85 | 150.93 | 204.11 | 91.91 | 112.21 | 0.00 | 0.00 |
Minimum of Months | 163.55 | 8.01 | 177.09 | 61.28 | 72.04 | 0.00 | 0.00 |
Maximum of Months | 444.68 | 360.29 | 228.51 | 119.24 | 148.91 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_2_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 61.89 | 391.43 | 102.75 | 38.65 | 64.11 | 0.00 | 0.00 |
February | 104.25 | 315.18 | 116.99 | 44.63 | 72.36 | 0.00 | 0.00 |
March | 202.15 | 180.24 | 170.27 | 67.38 | 102.89 | 0.00 | 0.00 |
April | 279.51 | 132.63 | 194.49 | 72.22 | 122.27 | 0.00 | 0.00 |
May | 331.92 | 72.72 | 202.62 | 61.51 | 141.11 | 0.00 | 0.00 |
June | 417.05 | 33.01 | 215.05 | 67.27 | 147.78 | 0.00 | 0.00 |
July | 417.87 | 15.82 | 202.70 | 60.30 | 142.40 | 0.00 | 0.00 |
August | 407.33 | 7.74 | 194.77 | 58.03 | 136.74 | 0.00 | 0.00 |
September | 274.38 | 50.16 | 156.58 | 52.56 | 104.02 | 0.00 | 0.00 |
October | 185.69 | 155.38 | 135.30 | 58.15 | 77.15 | 0.00 | 0.00 |
November | 118.16 | 232.68 | 109.83 | 39.72 | 70.10 | 0.00 | 0.00 |
December | 66.88 | 316.31 | 91.72 | 32.23 | 59.50 | 0.00 | 0.00 |
Annual Sum or Average | 239.66 | 157.83 | 157.97 | 54.43 | 103.54 | 0.00 | 0.00 |
Minimum of Months | 61.89 | 7.74 | 91.72 | 32.23 | 59.50 | 0.00 | 0.00 |
Maximum of Months | 417.87 | 391.43 | 215.05 | 72.22 | 147.78 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 165.66 | 186.31 | 152.89 | 106.21 | 46.68 | 0.00 | 0.00 |
February | 169.99 | 153.15 | 142.42 | 95.01 | 47.41 | 0.00 | 0.00 |
March | 175.83 | 92.67 | 130.23 | 68.34 | 61.89 | 0.00 | 0.00 |
April | 152.55 | 69.61 | 98.01 | 32.70 | 65.31 | 0.00 | 0.00 |
May | 136.71 | 37.57 | 78.78 | 9.64 | 69.14 | 0.00 | 0.00 |
June | 156.44 | 16.52 | 72.34 | 4.04 | 68.30 | 0.00 | 0.00 |
July | 167.59 | 7.49 | 72.57 | 4.89 | 67.67 | 0.00 | 0.00 |
August | 199.82 | 3.50 | 87.44 | 16.43 | 71.00 | 0.00 | 0.00 |
September | 181.55 | 25.77 | 98.72 | 38.41 | 60.31 | 0.00 | 0.00 |
October | 208.33 | 79.57 | 138.62 | 89.59 | 49.02 | 0.00 | 0.00 |
November | 200.24 | 115.47 | 151.44 | 101.06 | 50.39 | 0.00 | 0.00 |
December | 178.15 | 152.66 | 151.81 | 106.80 | 45.02 | 0.00 | 0.00 |
Annual Sum or Average | 174.46 | 77.98 | 114.48 | 55.91 | 58.58 | 0.00 | 0.00 |
Minimum of Months | 136.71 | 3.50 | 72.34 | 4.04 | 45.02 | 0.00 | 0.00 |
Maximum of Months | 208.33 | 186.31 | 152.89 | 106.80 | 71.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: BANQUET_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 15.34 | 1133.54 | 137.44 | 0.00 | 137.44 | 0.00 | 0.00 |
February | 64.78 | 902.16 | 152.33 | 0.00 | 152.33 | 0.00 | 0.00 |
March | 163.76 | 500.07 | 213.92 | 0.00 | 213.92 | 0.00 | 0.00 |
April | 338.63 | 354.59 | 259.38 | 1.51 | 257.87 | 0.00 | 0.00 |
May | 523.50 | 196.27 | 309.48 | 9.71 | 299.77 | 0.00 | 0.00 |
June | 747.01 | 97.29 | 340.37 | 22.32 | 318.05 | 0.00 | 0.00 |
July | 762.17 | 54.38 | 322.35 | 16.52 | 305.83 | 0.00 | 0.00 |
August | 704.78 | 32.35 | 286.31 | 3.36 | 282.94 | 0.00 | 0.00 |
September | 415.69 | 144.51 | 216.12 | 0.08 | 216.03 | 0.00 | 0.00 |
October | 179.62 | 427.67 | 164.21 | 0.00 | 164.21 | 0.00 | 0.00 |
November | 83.64 | 644.18 | 146.96 | 0.00 | 146.96 | 0.00 | 0.00 |
December | 17.13 | 904.84 | 127.05 | 0.00 | 127.05 | 0.00 | 0.00 |
Annual Sum or Average | 336.21 | 447.12 | 223.38 | 4.48 | 218.90 | 0.00 | 0.00 |
Minimum of Months | 15.34 | 32.35 | 127.05 | 0.00 | 127.05 | 0.00 | 0.00 |
Maximum of Months | 762.17 | 1133.54 | 340.37 | 22.32 | 318.05 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: DINING_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 14.48 | 1152.22 | 137.44 | 0.00 | 137.44 | 0.00 | 0.00 |
February | 62.36 | 920.08 | 152.33 | 0.00 | 152.33 | 0.00 | 0.00 |
March | 157.63 | 515.01 | 213.92 | 0.00 | 213.92 | 0.00 | 0.00 |
April | 329.74 | 367.12 | 259.38 | 1.51 | 257.87 | 0.00 | 0.00 |
May | 511.87 | 206.77 | 309.48 | 9.71 | 299.77 | 0.00 | 0.00 |
June | 732.67 | 105.00 | 340.37 | 22.32 | 318.05 | 0.00 | 0.00 |
July | 747.63 | 60.36 | 322.35 | 16.52 | 305.83 | 0.00 | 0.00 |
August | 690.13 | 37.82 | 286.31 | 3.36 | 282.94 | 0.00 | 0.00 |
September | 404.61 | 154.86 | 216.12 | 0.08 | 216.03 | 0.00 | 0.00 |
October | 173.61 | 442.36 | 164.21 | 0.00 | 164.21 | 0.00 | 0.00 |
November | 79.60 | 660.28 | 146.96 | 0.00 | 146.96 | 0.00 | 0.00 |
December | 15.74 | 923.43 | 127.05 | 0.00 | 127.05 | 0.00 | 0.00 |
Annual Sum or Average | 328.19 | 459.88 | 223.38 | 4.48 | 218.90 | 0.00 | 0.00 |
Minimum of Months | 14.48 | 37.82 | 127.05 | 0.00 | 127.05 | 0.00 | 0.00 |
Maximum of Months | 747.63 | 1152.22 | 340.37 | 22.32 | 318.05 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: KITCHEN_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 180.48 | 790.46 | 286.11 | 146.28 | 139.83 | 0.00 | 0.00 |
February | 298.15 | 649.10 | 322.47 | 174.39 | 148.09 | 0.00 | 0.00 |
March | 458.01 | 389.20 | 375.52 | 163.44 | 212.08 | 0.00 | 0.00 |
April | 637.90 | 287.18 | 413.53 | 163.85 | 249.68 | 0.00 | 0.00 |
May | 779.61 | 174.08 | 437.14 | 151.41 | 285.73 | 0.00 | 0.00 |
June | 939.45 | 91.39 | 448.80 | 152.90 | 295.91 | 0.00 | 0.00 |
July | 965.71 | 51.76 | 437.50 | 149.17 | 288.33 | 0.00 | 0.00 |
August | 936.05 | 33.00 | 413.96 | 136.02 | 277.94 | 0.00 | 0.00 |
September | 683.33 | 124.44 | 355.07 | 139.71 | 215.36 | 0.00 | 0.00 |
October | 492.54 | 338.02 | 337.68 | 175.45 | 162.23 | 0.00 | 0.00 |
November | 335.17 | 481.42 | 299.24 | 147.84 | 151.40 | 0.00 | 0.00 |
December | 210.48 | 646.47 | 273.51 | 141.94 | 131.57 | 0.00 | 0.00 |
Annual Sum or Average | 577.90 | 336.50 | 366.94 | 153.39 | 213.55 | 0.00 | 0.00 |
Minimum of Months | 180.48 | 33.00 | 273.51 | 136.02 | 131.57 | 0.00 | 0.00 |
Maximum of Months | 965.71 | 790.46 | 448.80 | 175.45 | 295.91 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORRIDOR_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 385.43 | 816.62 | 436.30 | 270.36 | 165.94 | 0.00 | 0.00 |
February | 433.82 | 664.07 | 414.75 | 241.86 | 172.89 | 0.00 | 0.00 |
March | 517.05 | 389.36 | 404.85 | 173.96 | 230.88 | 0.00 | 0.00 |
April | 524.26 | 285.36 | 338.41 | 83.76 | 254.65 | 0.00 | 0.00 |
May | 549.27 | 148.36 | 306.64 | 27.87 | 278.77 | 0.00 | 0.00 |
June | 677.22 | 64.45 | 300.82 | 17.93 | 282.89 | 0.00 | 0.00 |
July | 706.94 | 30.82 | 295.22 | 18.12 | 277.10 | 0.00 | 0.00 |
August | 772.22 | 14.38 | 320.72 | 42.98 | 277.74 | 0.00 | 0.00 |
September | 630.95 | 101.93 | 325.37 | 97.80 | 227.57 | 0.00 | 0.00 |
October | 608.44 | 330.29 | 409.15 | 228.06 | 181.08 | 0.00 | 0.00 |
November | 540.59 | 487.02 | 435.89 | 257.25 | 178.64 | 0.00 | 0.00 |
December | 436.16 | 660.23 | 430.00 | 271.85 | 158.15 | 0.00 | 0.00 |
Annual Sum or Average | 565.97 | 331.09 | 367.99 | 143.85 | 224.15 | 0.00 | 0.00 |
Minimum of Months | 385.43 | 14.38 | 295.22 | 17.93 | 158.15 | 0.00 | 0.00 |
Maximum of Months | 772.22 | 816.62 | 436.30 | 271.85 | 282.89 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: BASEMENT
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: RETAIL_1_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.161560E+10 | 0.160354E+10 | 0.141220E+10 | 0.981020E+09 | 0.431183E+09 | 0.00 | 0.00 |
February | 0.149293E+10 | 0.118962E+10 | 0.118818E+10 | 0.792686E+09 | 0.395494E+09 | 0.00 | 0.00 |
March | 0.171506E+10 | 0.806838E+09 | 0.120293E+10 | 0.631243E+09 | 0.571687E+09 | 0.00 | 0.00 |
April | 0.143523E+10 | 0.591169E+09 | 0.876087E+09 | 0.292293E+09 | 0.583795E+09 | 0.00 | 0.00 |
May | 0.132525E+10 | 0.334445E+09 | 0.727706E+09 | 89053889.35 | 0.638652E+09 | 0.00 | 0.00 |
June | 0.143256E+10 | 0.151348E+09 | 0.646621E+09 | 36100811.87 | 0.610520E+09 | 0.00 | 0.00 |
July | 0.157310E+10 | 72970874.98 | 0.670261E+09 | 45210453.17 | 0.625050E+09 | 0.00 | 0.00 |
August | 0.186764E+10 | 38818098.81 | 0.807634E+09 | 0.151787E+09 | 0.655847E+09 | 0.00 | 0.00 |
September | 0.167669E+10 | 0.225280E+09 | 0.882405E+09 | 0.343335E+09 | 0.539070E+09 | 0.00 | 0.00 |
October | 0.200065E+10 | 0.693962E+09 | 0.128037E+10 | 0.827554E+09 | 0.452812E+09 | 0.00 | 0.00 |
November | 0.187009E+10 | 0.966359E+09 | 0.135373E+10 | 0.903351E+09 | 0.450383E+09 | 0.00 | 0.00 |
December | 0.173551E+10 | 0.131497E+10 | 0.140226E+10 | 0.986443E+09 | 0.415820E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.197403E+11 | 0.798932E+10 | 0.124504E+11 | 0.608008E+10 | 0.637031E+10 | 0.00 | 0.00 |
Minimum of Months | 0.132525E+10 | 38818098.81 | 0.646621E+09 | 36100811.87 | 0.395494E+09 | 0.00 | 0.00 |
Maximum of Months | 0.200065E+10 | 0.160354E+10 | 0.141220E+10 | 0.986443E+09 | 0.655847E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: RETAIL_2_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: MECH_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: STORAGE_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: LAUNDRY_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CAFE_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.450228E+10 | 0.457489E+10 | 0.397667E+10 | 0.276249E+10 | 0.121418E+10 | 0.00 | 0.00 |
February | 0.416585E+10 | 0.340328E+10 | 0.334584E+10 | 0.223215E+10 | 0.111368E+10 | 0.00 | 0.00 |
March | 0.479056E+10 | 0.231194E+10 | 0.338737E+10 | 0.177754E+10 | 0.160983E+10 | 0.00 | 0.00 |
April | 0.401015E+10 | 0.169605E+10 | 0.246700E+10 | 0.823077E+09 | 0.164393E+10 | 0.00 | 0.00 |
May | 0.369865E+10 | 0.984590E+09 | 0.204917E+10 | 0.250770E+09 | 0.179840E+10 | 0.00 | 0.00 |
June | 0.399670E+10 | 0.473203E+09 | 0.182084E+10 | 0.101658E+09 | 0.171918E+10 | 0.00 | 0.00 |
July | 0.439432E+10 | 0.250022E+09 | 0.188741E+10 | 0.127310E+09 | 0.176010E+10 | 0.00 | 0.00 |
August | 0.522003E+10 | 0.152445E+09 | 0.227424E+10 | 0.427422E+09 | 0.184682E+10 | 0.00 | 0.00 |
September | 0.469335E+10 | 0.685678E+09 | 0.248479E+10 | 0.966809E+09 | 0.151798E+10 | 0.00 | 0.00 |
October | 0.560406E+10 | 0.200106E+10 | 0.360543E+10 | 0.233034E+10 | 0.127509E+10 | 0.00 | 0.00 |
November | 0.522784E+10 | 0.275761E+10 | 0.381203E+10 | 0.254378E+10 | 0.126825E+10 | 0.00 | 0.00 |
December | 0.484087E+10 | 0.375323E+10 | 0.394868E+10 | 0.277776E+10 | 0.117092E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.551447E+11 | 0.230440E+11 | 0.350595E+11 | 0.171211E+11 | 0.179384E+11 | 0.00 | 0.00 |
Minimum of Months | 0.369865E+10 | 0.152445E+09 | 0.182084E+10 | 0.101658E+09 | 0.111368E+10 | 0.00 | 0.00 |
Maximum of Months | 0.560406E+10 | 0.457489E+10 | 0.397667E+10 | 0.277776E+10 | 0.184682E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: LOBBY_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.593801E+10 | 0.612653E+10 | 0.516592E+10 | 0.358863E+10 | 0.157729E+10 | 0.00 | 0.00 |
February | 0.551118E+10 | 0.454886E+10 | 0.434643E+10 | 0.289969E+10 | 0.144674E+10 | 0.00 | 0.00 |
March | 0.636494E+10 | 0.307933E+10 | 0.440039E+10 | 0.230912E+10 | 0.209126E+10 | 0.00 | 0.00 |
April | 0.534703E+10 | 0.226605E+10 | 0.320478E+10 | 0.106922E+10 | 0.213555E+10 | 0.00 | 0.00 |
May | 0.494731E+10 | 0.131895E+10 | 0.266199E+10 | 0.325764E+09 | 0.233623E+10 | 0.00 | 0.00 |
June | 0.535320E+10 | 0.627907E+09 | 0.236538E+10 | 0.132059E+09 | 0.223332E+10 | 0.00 | 0.00 |
July | 0.589227E+10 | 0.325990E+09 | 0.245185E+10 | 0.165382E+09 | 0.228647E+10 | 0.00 | 0.00 |
August | 0.700896E+10 | 0.186106E+09 | 0.295437E+10 | 0.555246E+09 | 0.239913E+10 | 0.00 | 0.00 |
September | 0.627512E+10 | 0.899527E+09 | 0.322789E+10 | 0.125594E+10 | 0.197195E+10 | 0.00 | 0.00 |
October | 0.745768E+10 | 0.265095E+10 | 0.468365E+10 | 0.302724E+10 | 0.165641E+10 | 0.00 | 0.00 |
November | 0.693423E+10 | 0.366925E+10 | 0.495204E+10 | 0.330451E+10 | 0.164753E+10 | 0.00 | 0.00 |
December | 0.639450E+10 | 0.501322E+10 | 0.512956E+10 | 0.360846E+10 | 0.152109E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.734244E+11 | 0.307127E+11 | 0.455443E+11 | 0.222413E+11 | 0.233030E+11 | 0.00 | 0.00 |
Minimum of Months | 0.494731E+10 | 0.186106E+09 | 0.236538E+10 | 0.132059E+09 | 0.144674E+10 | 0.00 | 0.00 |
Maximum of Months | 0.745768E+10 | 0.612653E+10 | 0.516592E+10 | 0.360846E+10 | 0.239913E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_1_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.438591E+09 | 0.970630E+09 | 0.501844E+09 | 0.297480E+09 | 0.204364E+09 | 0.00 | 0.00 |
February | 0.492058E+09 | 0.716444E+09 | 0.465298E+09 | 0.264700E+09 | 0.200598E+09 | 0.00 | 0.00 |
March | 0.798808E+09 | 0.478800E+09 | 0.612039E+09 | 0.305281E+09 | 0.306758E+09 | 0.00 | 0.00 |
April | 0.884199E+09 | 0.347562E+09 | 0.581284E+09 | 0.244432E+09 | 0.336852E+09 | 0.00 | 0.00 |
May | 0.965049E+09 | 0.199491E+09 | 0.568158E+09 | 0.178638E+09 | 0.389520E+09 | 0.00 | 0.00 |
June | 0.110749E+10 | 89774507.37 | 0.559219E+09 | 0.173234E+09 | 0.385985E+09 | 0.00 | 0.00 |
July | 0.115742E+10 | 43574907.96 | 0.552093E+09 | 0.164131E+09 | 0.387962E+09 | 0.00 | 0.00 |
August | 0.120775E+10 | 21908810.45 | 0.571808E+09 | 0.184152E+09 | 0.387656E+09 | 0.00 | 0.00 |
September | 0.896733E+09 | 0.132797E+09 | 0.500287E+09 | 0.204092E+09 | 0.296195E+09 | 0.00 | 0.00 |
October | 0.809292E+09 | 0.413544E+09 | 0.552717E+09 | 0.319376E+09 | 0.233342E+09 | 0.00 | 0.00 |
November | 0.609670E+09 | 0.581865E+09 | 0.497906E+09 | 0.281572E+09 | 0.216334E+09 | 0.00 | 0.00 |
December | 0.466583E+09 | 0.792992E+09 | 0.474312E+09 | 0.281358E+09 | 0.192954E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.983364E+10 | 0.478938E+10 | 0.643697E+10 | 0.289845E+10 | 0.353852E+10 | 0.00 | 0.00 |
Minimum of Months | 0.438591E+09 | 21908810.45 | 0.465298E+09 | 0.164131E+09 | 0.192954E+09 | 0.00 | 0.00 |
Maximum of Months | 0.120775E+10 | 0.970630E+09 | 0.612039E+09 | 0.319376E+09 | 0.389520E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_2_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.165450E+09 | 0.105282E+10 | 0.275215E+09 | 0.103516E+09 | 0.171700E+09 | 0.00 | 0.00 |
February | 0.253651E+09 | 0.767366E+09 | 0.283022E+09 | 0.107973E+09 | 0.175050E+09 | 0.00 | 0.00 |
March | 0.548875E+09 | 0.486914E+09 | 0.456053E+09 | 0.180475E+09 | 0.275578E+09 | 0.00 | 0.00 |
April | 0.737912E+09 | 0.344178E+09 | 0.504114E+09 | 0.187201E+09 | 0.316912E+09 | 0.00 | 0.00 |
May | 0.906599E+09 | 0.193534E+09 | 0.542695E+09 | 0.164744E+09 | 0.377951E+09 | 0.00 | 0.00 |
June | 0.109760E+10 | 85768621.47 | 0.557408E+09 | 0.174362E+09 | 0.383046E+09 | 0.00 | 0.00 |
July | 0.113554E+10 | 42406241.79 | 0.542915E+09 | 0.161512E+09 | 0.381403E+09 | 0.00 | 0.00 |
August | 0.110686E+10 | 21199656.78 | 0.521677E+09 | 0.155428E+09 | 0.366249E+09 | 0.00 | 0.00 |
September | 0.723219E+09 | 0.130739E+09 | 0.405848E+09 | 0.136240E+09 | 0.269608E+09 | 0.00 | 0.00 |
October | 0.504308E+09 | 0.419879E+09 | 0.362400E+09 | 0.155754E+09 | 0.206646E+09 | 0.00 | 0.00 |
November | 0.307038E+09 | 0.609942E+09 | 0.284668E+09 | 0.102964E+09 | 0.181704E+09 | 0.00 | 0.00 |
December | 0.177251E+09 | 0.854930E+09 | 0.245674E+09 | 86321527.55 | 0.159353E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.766430E+10 | 0.500967E+10 | 0.498169E+10 | 0.171649E+10 | 0.326520E+10 | 0.00 | 0.00 |
Minimum of Months | 0.165450E+09 | 21199656.78 | 0.245674E+09 | 86321527.55 | 0.159353E+09 | 0.00 | 0.00 |
Maximum of Months | 0.113554E+10 | 0.105282E+10 | 0.557408E+09 | 0.187201E+09 | 0.383046E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.246514E+09 | 0.270746E+09 | 0.223330E+09 | 0.155141E+09 | 68188813.41 | 0.00 | 0.00 |
February | 0.226458E+09 | 0.207535E+09 | 0.187902E+09 | 0.125357E+09 | 62544840.67 | 0.00 | 0.00 |
March | 0.251956E+09 | 0.159024E+09 | 0.190235E+09 | 99826196.68 | 90408627.06 | 0.00 | 0.00 |
April | 0.209513E+09 | 0.120442E+09 | 0.138547E+09 | 46223853.60 | 92323562.43 | 0.00 | 0.00 |
May | 0.191440E+09 | 75158938.60 | 0.115082E+09 | 14083185.96 | 0.100999E+09 | 0.00 | 0.00 |
June | 0.209324E+09 | 38371673.03 | 0.102259E+09 | 5709065.05 | 96550134.41 | 0.00 | 0.00 |
July | 0.230701E+09 | 23447320.01 | 0.105998E+09 | 7149684.58 | 98847981.78 | 0.00 | 0.00 |
August | 0.277443E+09 | 16209306.97 | 0.127722E+09 | 24003960.40 | 0.103718E+09 | 0.00 | 0.00 |
September | 0.248705E+09 | 55194865.33 | 0.139546E+09 | 54295818.95 | 85250458.26 | 0.00 | 0.00 |
October | 0.300072E+09 | 0.140545E+09 | 0.202481E+09 | 0.130871E+09 | 71609428.64 | 0.00 | 0.00 |
November | 0.279020E+09 | 0.187011E+09 | 0.214083E+09 | 0.142858E+09 | 71225121.93 | 0.00 | 0.00 |
December | 0.260050E+09 | 0.237962E+09 | 0.221757E+09 | 0.155998E+09 | 65759141.47 | 0.00 | 0.00 |
Annual Sum or Average | 0.293120E+10 | 0.153165E+10 | 0.196894E+10 | 0.961517E+09 | 0.100743E+10 | 0.00 | 0.00 |
Minimum of Months | 0.191440E+09 | 16209306.97 | 0.102259E+09 | 5709065.05 | 62544840.67 | 0.00 | 0.00 |
Maximum of Months | 0.300072E+09 | 0.270746E+09 | 0.223330E+09 | 0.155998E+09 | 0.103718E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 5334960.77 | 0.330818E+09 | 42076451.99 | 0.00 | 42076451.99 | 0.00 | 0.00 |
February | 19102050.03 | 0.236992E+09 | 42124339.93 | 0.00 | 42124339.93 | 0.00 | 0.00 |
March | 52442263.25 | 0.143356E+09 | 65492691.15 | 1318.99 | 65491372.16 | 0.00 | 0.00 |
April | 0.100770E+09 | 96654974.84 | 76848851.72 | 448829.91 | 76400021.81 | 0.00 | 0.00 |
May | 0.159884E+09 | 50992190.01 | 94747450.04 | 2971603.27 | 91775846.77 | 0.00 | 0.00 |
June | 0.221632E+09 | 21128098.74 | 0.100844E+09 | 6613320.29 | 94230889.24 | 0.00 | 0.00 |
July | 0.235380E+09 | 10045407.66 | 98689421.90 | 5056973.36 | 93632448.53 | 0.00 | 0.00 |
August | 0.219043E+09 | 4421579.59 | 87654522.95 | 1029768.70 | 86624754.24 | 0.00 | 0.00 |
September | 0.122506E+09 | 35146067.13 | 64031230.67 | 25170.94 | 64006059.72 | 0.00 | 0.00 |
October | 55913344.89 | 0.122038E+09 | 50273499.29 | 0.00 | 50273499.29 | 0.00 | 0.00 |
November | 26433869.61 | 0.181935E+09 | 43541540.27 | 0.00 | 43541540.27 | 0.00 | 0.00 |
December | 6447731.02 | 0.264041E+09 | 38896548.34 | 0.00 | 38896548.34 | 0.00 | 0.00 |
Annual Sum or Average | 0.122489E+10 | 0.149757E+10 | 0.805221E+09 | 16146985.47 | 0.789074E+09 | 0.00 | 0.00 |
Minimum of Months | 5334960.77 | 4421579.59 | 38896548.34 | 0.00 | 38896548.34 | 0.00 | 0.00 |
Maximum of Months | 0.235380E+09 | 0.330818E+09 | 0.100844E+09 | 6613320.29 | 94230889.24 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_5_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.417072E+09 | 0.956496E+09 | 0.496486E+09 | 0.292891E+09 | 0.203596E+09 | 0.00 | 0.00 |
February | 0.500788E+09 | 0.700252E+09 | 0.481219E+09 | 0.289311E+09 | 0.191908E+09 | 0.00 | 0.00 |
March | 0.720967E+09 | 0.455928E+09 | 0.580914E+09 | 0.281299E+09 | 0.299614E+09 | 0.00 | 0.00 |
April | 0.845832E+09 | 0.323086E+09 | 0.574551E+09 | 0.240974E+09 | 0.333577E+09 | 0.00 | 0.00 |
May | 0.995017E+09 | 0.184664E+09 | 0.598187E+09 | 0.209729E+09 | 0.388458E+09 | 0.00 | 0.00 |
June | 0.113721E+10 | 81743359.04 | 0.582588E+09 | 0.197605E+09 | 0.384983E+09 | 0.00 | 0.00 |
July | 0.121690E+10 | 41801400.87 | 0.590525E+09 | 0.201092E+09 | 0.389433E+09 | 0.00 | 0.00 |
August | 0.122089E+10 | 20590548.32 | 0.579466E+09 | 0.196526E+09 | 0.382940E+09 | 0.00 | 0.00 |
September | 0.903138E+09 | 0.126927E+09 | 0.507408E+09 | 0.214997E+09 | 0.292411E+09 | 0.00 | 0.00 |
October | 0.780213E+09 | 0.396845E+09 | 0.547407E+09 | 0.316785E+09 | 0.230622E+09 | 0.00 | 0.00 |
November | 0.583866E+09 | 0.562062E+09 | 0.494448E+09 | 0.280911E+09 | 0.213537E+09 | 0.00 | 0.00 |
December | 0.459704E+09 | 0.775097E+09 | 0.480619E+09 | 0.287609E+09 | 0.193010E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.978160E+10 | 0.462549E+10 | 0.651382E+10 | 0.300973E+10 | 0.350409E+10 | 0.00 | 0.00 |
Minimum of Months | 0.417072E+09 | 20590548.32 | 0.480619E+09 | 0.196526E+09 | 0.191908E+09 | 0.00 | 0.00 |
Maximum of Months | 0.122089E+10 | 0.956496E+09 | 0.598187E+09 | 0.316785E+09 | 0.389433E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_6_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.124865E+09 | 0.101875E+10 | 0.269858E+09 | 98926312.94 | 0.170931E+09 | 0.00 | 0.00 |
February | 0.237081E+09 | 0.725457E+09 | 0.298943E+09 | 0.132584E+09 | 0.166359E+09 | 0.00 | 0.00 |
March | 0.459311E+09 | 0.452067E+09 | 0.424928E+09 | 0.156494E+09 | 0.268435E+09 | 0.00 | 0.00 |
April | 0.697496E+09 | 0.318912E+09 | 0.497381E+09 | 0.183744E+09 | 0.313637E+09 | 0.00 | 0.00 |
May | 0.939861E+09 | 0.182646E+09 | 0.572725E+09 | 0.195836E+09 | 0.376889E+09 | 0.00 | 0.00 |
June | 0.113094E+10 | 81353837.75 | 0.580777E+09 | 0.198732E+09 | 0.382045E+09 | 0.00 | 0.00 |
July | 0.119599E+10 | 41621054.32 | 0.581347E+09 | 0.198474E+09 | 0.382873E+09 | 0.00 | 0.00 |
August | 0.111999E+10 | 20096111.34 | 0.529335E+09 | 0.167803E+09 | 0.361533E+09 | 0.00 | 0.00 |
September | 0.728120E+09 | 0.124665E+09 | 0.412969E+09 | 0.147145E+09 | 0.265824E+09 | 0.00 | 0.00 |
October | 0.462259E+09 | 0.391723E+09 | 0.357089E+09 | 0.153163E+09 | 0.203926E+09 | 0.00 | 0.00 |
November | 0.255166E+09 | 0.562514E+09 | 0.281211E+09 | 0.102303E+09 | 0.178908E+09 | 0.00 | 0.00 |
December | 0.134634E+09 | 0.800428E+09 | 0.251981E+09 | 92572432.32 | 0.159409E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.748571E+10 | 0.472023E+10 | 0.505854E+10 | 0.182778E+10 | 0.323077E+10 | 0.00 | 0.00 |
Minimum of Months | 0.124865E+09 | 20096111.34 | 0.251981E+09 | 92572432.32 | 0.159409E+09 | 0.00 | 0.00 |
Maximum of Months | 0.119599E+10 | 0.101875E+10 | 0.581347E+09 | 0.198732E+09 | 0.382873E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORRIDOR_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.464402E+09 | 0.124082E+10 | 0.575045E+09 | 0.336147E+09 | 0.238898E+09 | 0.00 | 0.00 |
February | 0.496012E+09 | 0.907860E+09 | 0.498387E+09 | 0.271614E+09 | 0.226773E+09 | 0.00 | 0.00 |
March | 0.699323E+09 | 0.584678E+09 | 0.554065E+09 | 0.216298E+09 | 0.337767E+09 | 0.00 | 0.00 |
April | 0.730035E+09 | 0.413471E+09 | 0.466674E+09 | 0.101127E+09 | 0.365548E+09 | 0.00 | 0.00 |
May | 0.830003E+09 | 0.222646E+09 | 0.454606E+09 | 36951836.71 | 0.417654E+09 | 0.00 | 0.00 |
June | 0.994546E+09 | 0.100755E+09 | 0.440030E+09 | 26696625.66 | 0.413333E+09 | 0.00 | 0.00 |
July | 0.106616E+10 | 53392191.55 | 0.443462E+09 | 26446478.24 | 0.417015E+09 | 0.00 | 0.00 |
August | 0.112996E+10 | 28275737.57 | 0.466627E+09 | 54240731.23 | 0.412387E+09 | 0.00 | 0.00 |
September | 0.862396E+09 | 0.157432E+09 | 0.441071E+09 | 0.117698E+09 | 0.323373E+09 | 0.00 | 0.00 |
October | 0.814212E+09 | 0.496630E+09 | 0.547629E+09 | 0.283562E+09 | 0.264067E+09 | 0.00 | 0.00 |
November | 0.675533E+09 | 0.710920E+09 | 0.558184E+09 | 0.309534E+09 | 0.248651E+09 | 0.00 | 0.00 |
December | 0.537969E+09 | 0.999895E+09 | 0.564750E+09 | 0.338005E+09 | 0.226745E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.930055E+10 | 0.591678E+10 | 0.601053E+10 | 0.211832E+10 | 0.389221E+10 | 0.00 | 0.00 |
Minimum of Months | 0.464402E+09 | 28275737.57 | 0.440030E+09 | 26446478.24 | 0.226745E+09 | 0.00 | 0.00 |
Maximum of Months | 0.112996E+10 | 0.124082E+10 | 0.575045E+09 | 0.338005E+09 | 0.417654E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_1_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.438051E+09 | 0.964996E+09 | 0.501844E+09 | 0.297480E+09 | 0.204364E+09 | 0.00 | 0.00 |
February | 0.488716E+09 | 0.711833E+09 | 0.465298E+09 | 0.264700E+09 | 0.200598E+09 | 0.00 | 0.00 |
March | 0.787963E+09 | 0.475468E+09 | 0.612039E+09 | 0.305281E+09 | 0.306758E+09 | 0.00 | 0.00 |
April | 0.869359E+09 | 0.347283E+09 | 0.581284E+09 | 0.244432E+09 | 0.336852E+09 | 0.00 | 0.00 |
May | 0.947122E+09 | 0.200634E+09 | 0.568158E+09 | 0.178638E+09 | 0.389520E+09 | 0.00 | 0.00 |
June | 0.109078E+10 | 89493719.87 | 0.559219E+09 | 0.173234E+09 | 0.385985E+09 | 0.00 | 0.00 |
July | 0.114094E+10 | 43433873.84 | 0.552093E+09 | 0.164131E+09 | 0.387962E+09 | 0.00 | 0.00 |
August | 0.119102E+10 | 21462016.01 | 0.571808E+09 | 0.184152E+09 | 0.387656E+09 | 0.00 | 0.00 |
September | 0.883502E+09 | 0.132268E+09 | 0.500287E+09 | 0.204092E+09 | 0.296195E+09 | 0.00 | 0.00 |
October | 0.799057E+09 | 0.410762E+09 | 0.552717E+09 | 0.319376E+09 | 0.233342E+09 | 0.00 | 0.00 |
November | 0.605689E+09 | 0.576560E+09 | 0.497906E+09 | 0.281572E+09 | 0.216334E+09 | 0.00 | 0.00 |
December | 0.466290E+09 | 0.785552E+09 | 0.474312E+09 | 0.281358E+09 | 0.192954E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.970849E+10 | 0.475975E+10 | 0.643697E+10 | 0.289845E+10 | 0.353852E+10 | 0.00 | 0.00 |
Minimum of Months | 0.438051E+09 | 21462016.01 | 0.465298E+09 | 0.164131E+09 | 0.192954E+09 | 0.00 | 0.00 |
Maximum of Months | 0.119102E+10 | 0.964996E+09 | 0.612039E+09 | 0.319376E+09 | 0.389520E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_2_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.165765E+09 | 0.104840E+10 | 0.275215E+09 | 0.103516E+09 | 0.171700E+09 | 0.00 | 0.00 |
February | 0.252205E+09 | 0.762494E+09 | 0.283022E+09 | 0.107973E+09 | 0.175050E+09 | 0.00 | 0.00 |
March | 0.541442E+09 | 0.482745E+09 | 0.456053E+09 | 0.180475E+09 | 0.275578E+09 | 0.00 | 0.00 |
April | 0.724497E+09 | 0.343789E+09 | 0.504114E+09 | 0.187201E+09 | 0.316912E+09 | 0.00 | 0.00 |
May | 0.889011E+09 | 0.194777E+09 | 0.542695E+09 | 0.164744E+09 | 0.377951E+09 | 0.00 | 0.00 |
June | 0.108099E+10 | 85567322.16 | 0.557408E+09 | 0.174362E+09 | 0.383046E+09 | 0.00 | 0.00 |
July | 0.111922E+10 | 42379540.52 | 0.542915E+09 | 0.161512E+09 | 0.381403E+09 | 0.00 | 0.00 |
August | 0.109098E+10 | 20740751.24 | 0.521677E+09 | 0.155428E+09 | 0.366249E+09 | 0.00 | 0.00 |
September | 0.711193E+09 | 0.130024E+09 | 0.405848E+09 | 0.136240E+09 | 0.269608E+09 | 0.00 | 0.00 |
October | 0.497347E+09 | 0.416183E+09 | 0.362400E+09 | 0.155754E+09 | 0.206646E+09 | 0.00 | 0.00 |
November | 0.306280E+09 | 0.603112E+09 | 0.284668E+09 | 0.102964E+09 | 0.181704E+09 | 0.00 | 0.00 |
December | 0.179119E+09 | 0.847203E+09 | 0.245674E+09 | 86321527.55 | 0.159353E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.755805E+10 | 0.497742E+10 | 0.498169E+10 | 0.171649E+10 | 0.326520E+10 | 0.00 | 0.00 |
Minimum of Months | 0.165765E+09 | 20740751.24 | 0.245674E+09 | 86321527.55 | 0.159353E+09 | 0.00 | 0.00 |
Maximum of Months | 0.111922E+10 | 0.104840E+10 | 0.557408E+09 | 0.187201E+09 | 0.383046E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.443710E+09 | 0.499022E+09 | 0.409499E+09 | 0.284468E+09 | 0.125032E+09 | 0.00 | 0.00 |
February | 0.411232E+09 | 0.370489E+09 | 0.344539E+09 | 0.229856E+09 | 0.114683E+09 | 0.00 | 0.00 |
March | 0.470938E+09 | 0.248208E+09 | 0.348816E+09 | 0.183042E+09 | 0.165774E+09 | 0.00 | 0.00 |
April | 0.395422E+09 | 0.180428E+09 | 0.254042E+09 | 84756499.22 | 0.169285E+09 | 0.00 | 0.00 |
May | 0.366177E+09 | 0.100619E+09 | 0.211016E+09 | 25823064.22 | 0.185193E+09 | 0.00 | 0.00 |
June | 0.405500E+09 | 42826155.30 | 0.187503E+09 | 10468196.17 | 0.177035E+09 | 0.00 | 0.00 |
July | 0.448863E+09 | 20060345.06 | 0.194358E+09 | 13109729.90 | 0.181249E+09 | 0.00 | 0.00 |
August | 0.535207E+09 | 9377507.29 | 0.234192E+09 | 44013890.93 | 0.190178E+09 | 0.00 | 0.00 |
September | 0.470573E+09 | 66807785.69 | 0.255873E+09 | 99557331.94 | 0.156316E+09 | 0.00 | 0.00 |
October | 0.557997E+09 | 0.213129E+09 | 0.371270E+09 | 0.239967E+09 | 0.131304E+09 | 0.00 | 0.00 |
November | 0.519017E+09 | 0.299297E+09 | 0.392545E+09 | 0.261946E+09 | 0.130599E+09 | 0.00 | 0.00 |
December | 0.477148E+09 | 0.408882E+09 | 0.406617E+09 | 0.286040E+09 | 0.120577E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.550178E+10 | 0.245915E+10 | 0.361027E+10 | 0.176305E+10 | 0.184722E+10 | 0.00 | 0.00 |
Minimum of Months | 0.366177E+09 | 9377507.29 | 0.187503E+09 | 10468196.17 | 0.114683E+09 | 0.00 | 0.00 |
Maximum of Months | 0.557997E+09 | 0.499022E+09 | 0.409499E+09 | 0.286040E+09 | 0.190178E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: BANQUET_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 41089703.00 | 0.303607E+10 | 0.368106E+09 | 0.00 | 0.368106E+09 | 0.00 | 0.00 |
February | 0.156720E+09 | 0.218249E+10 | 0.368525E+09 | 0.00 | 0.368525E+09 | 0.00 | 0.00 |
March | 0.438627E+09 | 0.133939E+10 | 0.572963E+09 | 11539.19 | 0.572952E+09 | 0.00 | 0.00 |
April | 0.877728E+09 | 0.919102E+09 | 0.672313E+09 | 3926592.47 | 0.668386E+09 | 0.00 | 0.00 |
May | 0.140213E+10 | 0.525684E+09 | 0.828899E+09 | 25997097.83 | 0.802902E+09 | 0.00 | 0.00 |
June | 0.193624E+10 | 0.252164E+09 | 0.882236E+09 | 57856691.74 | 0.824380E+09 | 0.00 | 0.00 |
July | 0.204140E+10 | 0.145651E+09 | 0.863385E+09 | 44240976.70 | 0.819144E+09 | 0.00 | 0.00 |
August | 0.188768E+10 | 86647929.46 | 0.766846E+09 | 9008940.72 | 0.757837E+09 | 0.00 | 0.00 |
September | 0.107748E+10 | 0.374574E+09 | 0.560178E+09 | 220208.23 | 0.559958E+09 | 0.00 | 0.00 |
October | 0.481081E+09 | 0.114546E+10 | 0.439818E+09 | 0.00 | 0.439818E+09 | 0.00 | 0.00 |
November | 0.216803E+09 | 0.166972E+10 | 0.380924E+09 | 0.00 | 0.380924E+09 | 0.00 | 0.00 |
December | 45874640.42 | 0.242352E+10 | 0.340287E+09 | 0.00 | 0.340287E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.106029E+11 | 0.141005E+11 | 0.704448E+10 | 0.141262E+09 | 0.690322E+10 | 0.00 | 0.00 |
Minimum of Months | 41089703.00 | 86647929.46 | 0.340287E+09 | 0.00 | 0.340287E+09 | 0.00 | 0.00 |
Maximum of Months | 0.204140E+10 | 0.303607E+10 | 0.882236E+09 | 57856691.74 | 0.824380E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: DINING_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 38795070.93 | 0.308612E+10 | 0.368106E+09 | 0.00 | 0.368106E+09 | 0.00 | 0.00 |
February | 0.150856E+09 | 0.222587E+10 | 0.368525E+09 | 0.00 | 0.368525E+09 | 0.00 | 0.00 |
March | 0.422183E+09 | 0.137941E+10 | 0.572963E+09 | 11539.19 | 0.572952E+09 | 0.00 | 0.00 |
April | 0.854690E+09 | 0.951570E+09 | 0.672313E+09 | 3926592.47 | 0.668386E+09 | 0.00 | 0.00 |
May | 0.137100E+10 | 0.553806E+09 | 0.828899E+09 | 25997097.83 | 0.802902E+09 | 0.00 | 0.00 |
June | 0.189907E+10 | 0.272158E+09 | 0.882236E+09 | 57856691.74 | 0.824380E+09 | 0.00 | 0.00 |
July | 0.200244E+10 | 0.161680E+09 | 0.863385E+09 | 44240976.70 | 0.819144E+09 | 0.00 | 0.00 |
August | 0.184843E+10 | 0.101289E+09 | 0.766846E+09 | 9008940.72 | 0.757837E+09 | 0.00 | 0.00 |
September | 0.104876E+10 | 0.401400E+09 | 0.560178E+09 | 220208.23 | 0.559958E+09 | 0.00 | 0.00 |
October | 0.464986E+09 | 0.118483E+10 | 0.439818E+09 | 0.00 | 0.439818E+09 | 0.00 | 0.00 |
November | 0.206314E+09 | 0.171143E+10 | 0.380924E+09 | 0.00 | 0.380924E+09 | 0.00 | 0.00 |
December | 42166387.22 | 0.247333E+10 | 0.340287E+09 | 0.00 | 0.340287E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.103497E+11 | 0.145029E+11 | 0.704448E+10 | 0.141262E+09 | 0.690322E+10 | 0.00 | 0.00 |
Minimum of Months | 38795070.93 | 0.101289E+09 | 0.340287E+09 | 0.00 | 0.340287E+09 | 0.00 | 0.00 |
Maximum of Months | 0.200244E+10 | 0.308612E+10 | 0.882236E+09 | 57856691.74 | 0.824380E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: KITCHEN_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.483394E+09 | 0.211716E+10 | 0.766313E+09 | 0.391803E+09 | 0.374510E+09 | 0.00 | 0.00 |
February | 0.721274E+09 | 0.157031E+10 | 0.780127E+09 | 0.421877E+09 | 0.358251E+09 | 0.00 | 0.00 |
March | 0.122674E+10 | 0.104245E+10 | 0.100579E+10 | 0.437771E+09 | 0.568023E+09 | 0.00 | 0.00 |
April | 0.165345E+10 | 0.744382E+09 | 0.107188E+10 | 0.424692E+09 | 0.647183E+09 | 0.00 | 0.00 |
May | 0.208811E+10 | 0.466263E+09 | 0.117085E+10 | 0.405538E+09 | 0.765309E+09 | 0.00 | 0.00 |
June | 0.243506E+10 | 0.236884E+09 | 0.116330E+10 | 0.396310E+09 | 0.766990E+09 | 0.00 | 0.00 |
July | 0.258656E+10 | 0.138632E+09 | 0.117181E+10 | 0.399539E+09 | 0.772269E+09 | 0.00 | 0.00 |
August | 0.250712E+10 | 88398181.36 | 0.110874E+10 | 0.364305E+09 | 0.744437E+09 | 0.00 | 0.00 |
September | 0.177118E+10 | 0.322550E+09 | 0.920329E+09 | 0.362120E+09 | 0.558209E+09 | 0.00 | 0.00 |
October | 0.131922E+10 | 0.905364E+09 | 0.904454E+09 | 0.469926E+09 | 0.434528E+09 | 0.00 | 0.00 |
November | 0.868765E+09 | 0.124784E+10 | 0.775627E+09 | 0.383200E+09 | 0.392427E+09 | 0.00 | 0.00 |
December | 0.563754E+09 | 0.173149E+10 | 0.732571E+09 | 0.380168E+09 | 0.352403E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.182246E+11 | 0.106117E+11 | 0.115718E+11 | 0.483725E+10 | 0.673454E+10 | 0.00 | 0.00 |
Minimum of Months | 0.483394E+09 | 88398181.36 | 0.732571E+09 | 0.362120E+09 | 0.352403E+09 | 0.00 | 0.00 |
Maximum of Months | 0.258656E+10 | 0.211716E+10 | 0.117181E+10 | 0.469926E+09 | 0.772269E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORRIDOR_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.103234E+10 | 0.218722E+10 | 0.116859E+10 | 0.724128E+09 | 0.444462E+09 | 0.00 | 0.00 |
February | 0.104950E+10 | 0.160652E+10 | 0.100337E+10 | 0.585111E+09 | 0.418262E+09 | 0.00 | 0.00 |
March | 0.138487E+10 | 0.104285E+10 | 0.108434E+10 | 0.465948E+09 | 0.618396E+09 | 0.00 | 0.00 |
April | 0.135888E+10 | 0.739652E+09 | 0.877147E+09 | 0.217098E+09 | 0.660049E+09 | 0.00 | 0.00 |
May | 0.147116E+10 | 0.397370E+09 | 0.821300E+09 | 74645838.28 | 0.746654E+09 | 0.00 | 0.00 |
June | 0.175535E+10 | 0.167052E+09 | 0.779732E+09 | 46480736.68 | 0.733252E+09 | 0.00 | 0.00 |
July | 0.189346E+10 | 82536722.48 | 0.790720E+09 | 48537407.44 | 0.742182E+09 | 0.00 | 0.00 |
August | 0.206830E+10 | 38522443.93 | 0.859026E+09 | 0.115128E+09 | 0.743898E+09 | 0.00 | 0.00 |
September | 0.163543E+10 | 0.264196E+09 | 0.843369E+09 | 0.253504E+09 | 0.589865E+09 | 0.00 | 0.00 |
October | 0.162965E+10 | 0.884652E+09 | 0.109586E+10 | 0.610848E+09 | 0.485011E+09 | 0.00 | 0.00 |
November | 0.140121E+10 | 0.126235E+10 | 0.112983E+10 | 0.666797E+09 | 0.463028E+09 | 0.00 | 0.00 |
December | 0.116821E+10 | 0.176836E+10 | 0.115171E+10 | 0.728130E+09 | 0.423585E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.178484E+11 | 0.104413E+11 | 0.116050E+11 | 0.453636E+10 | 0.706864E+10 | 0.00 | 0.00 |
Minimum of Months | 0.103234E+10 | 38522443.93 | 0.779732E+09 | 46480736.68 | 0.418262E+09 | 0.00 | 0.00 |
Maximum of Months | 0.206830E+10 | 0.218722E+10 | 0.116859E+10 | 0.728130E+09 | 0.746654E+09 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | 3.96 | 1.39 | -3.0 | 4.56 | -7.8 | 48.74 | 150.20 | 0.00 |
February | 7.94 | 4.18 | -1.3 | 5.19 | -4.0 | 51.84 | 169.20 | 0.00 |
March | 13.76 | 8.97 | 3.80 | 4.89 | 2.25 | 76.95 | 193.22 | 0.00 |
April | 17.21 | 12.54 | 8.82 | 3.95 | 6.45 | 95.37 | 211.82 | 0.00 |
May | 20.84 | 16.44 | 13.69 | 3.50 | 11.46 | 117.34 | 200.00 | 0.00 |
June | 24.80 | 19.35 | 16.45 | 3.85 | 15.08 | 121.81 | 213.08 | 0.00 |
July | 26.06 | 21.68 | 19.85 | 3.24 | 17.64 | 119.92 | 194.46 | 0.00 |
August | 26.55 | 22.42 | 20.72 | 3.39 | 18.21 | 115.12 | 179.15 | 0.00 |
September | 22.53 | 18.74 | 16.82 | 3.06 | 13.44 | 83.74 | 156.58 | 0.02 |
October | 16.03 | 13.02 | 10.77 | 4.05 | 5.85 | 53.01 | 190.38 | 0.00 |
November | 11.94 | 8.22 | 4.17 | 4.16 | 0.30 | 52.20 | 150.38 | 0.00 |
December | 7.70 | 4.64 | 0.26 | 4.69 | -4.1 | 44.81 | 142.03 | 0.00 |
Annual Sum or Average | 16.65 | 12.68 | 9.31 | 4.04 | 6.29 | 81.91 | 179.25 | 0.00 |
Minimum of Months | 3.96 | 1.39 | -3.0 | 3.06 | -7.8 | 44.81 | 142.03 | 0.00 |
Maximum of Months | 26.55 | 22.42 | 20.72 | 5.19 | 18.21 | 121.81 | 213.08 | 0.02 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 21.10 | 31-JAN-14:00 | 12.97 | 6.70 | 5.70 | 12.22 | 200.50 | 90.50 |
February | 25.00 | 26-FEB-14:00 | 12.75 | 1.70 | 4.10 | 8.15 | 91.50 | 816.00 |
March | 27.80 | 30-MAR-13:00 | 17.87 | 12.20 | 5.70 | 16.30 | 231.50 | 710.50 |
April | 28.90 | 17-APR-14:20 | 16.56 | 8.13 | 2.03 | 13.35 | 125.83 | 887.67 |
May | 30.60 | 19-MAY-13:00 | 18.49 | 11.70 | 4.60 | 15.76 | 140.00 | 875.50 |
June | 34.40 | 06-JUN-14:00 | 22.39 | 17.20 | 8.20 | 22.13 | 251.00 | 561.00 |
July | 36.70 | 08-JUL-14:00 | 23.91 | 18.90 | 2.10 | 24.66 | 274.00 | 567.00 |
August | 35.00 | 01-AUG-14:00 | 23.84 | 19.40 | 2.60 | 26.15 | 306.00 | 508.00 |
September | 31.70 | 07-SEP-15:09 | 23.05 | 19.60 | 4.02 | 22.55 | 218.67 | 591.33 |
October | 30.00 | 10-OCT-15:00 | 20.56 | 16.10 | 3.60 | 17.57 | 97.00 | 561.00 |
November | 24.40 | 05-NOV-15:00 | 17.95 | 14.40 | 2.10 | 14.10 | 117.50 | 361.50 |
December | 22.80 | 12-DEC-14:20 | 16.78 | 13.33 | 5.20 | 13.35 | 144.17 | 433.83 |
Annual Sum or Average | ||||||||
Minimum of Months | 21.10 | 12.75 | 1.70 | 2.03 | 8.15 | 91.50 | 90.50 | |
Maximum of Months | 36.70 | 23.91 | 19.60 | 8.20 | 26.15 | 306.00 | 887.67 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -6.7 | 14-JAN-06:10 | -7.8 | -10.6 | 4.95 | -24.7 | 0.00 | 0.00 |
February | -12.8 | 12-FEB-06:00 | -13.8 | -18.3 | 7.20 | -30.1 | 0.00 | 0.00 |
March | 1.10 | 19-MAR-06:00 | -1.5 | -6.1 | 0.00 | -16.2 | 17.00 | 290.50 |
April | 0.00 | 06-APR-04:00 | -1.1 | -2.8 | 3.10 | -16.5 | 0.00 | 0.00 |
May | 7.80 | 11-MAY-05:00 | 5.45 | 2.80 | 4.10 | -7.8 | 21.50 | 204.50 |
June | 11.10 | 10-JUN-04:00 | 8.73 | 6.70 | 0.00 | -2.5 | 0.00 | 0.00 |
July | 17.20 | 28-JUL-22:00 | 16.88 | 16.70 | 4.10 | 14.28 | 0.00 | 0.00 |
August | 18.30 | 25-AUG-05:00 | 17.20 | 16.70 | 3.60 | 5.13 | 0.00 | 0.00 |
September | 11.70 | 29-SEP-03:00 | 11.07 | 10.60 | 2.60 | -2.3 | 0.00 | 0.00 |
October | 2.20 | 26-OCT-04:00 | 1.95 | 1.70 | 3.10 | -13.4 | 0.00 | 0.00 |
November | -3.3 | 22-NOV-05:00 | -4.0 | -5.6 | 5.20 | -20.2 | 0.00 | 0.00 |
December | -5.6 | 18-DEC-07:00 | -7.3 | -11.7 | 2.60 | -22.7 | 17.00 | 320.50 |
Annual Sum or Average | ||||||||
Minimum of Months | -12.8 | -13.8 | -18.3 | 0.00 | -30.1 | 0.00 | 0.00 | |
Maximum of Months | 18.30 | 17.20 | 16.70 | 7.20 | 14.28 | 21.50 | 320.50 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 16.51 | 19-JAN-21:00 | 18.30 | 15.60 | 8.80 | 15.21 | 0.00 | 0.00 |
February | 15.81 | 18-FEB-15:00 | 17.20 | 15.00 | 5.20 | 13.91 | 73.00 | 1.00 |
March | 18.16 | 30-MAR-12:30 | 25.85 | 13.85 | 5.45 | 15.39 | 323.00 | 600.00 |
April | 20.01 | 04-APR-13:00 | 25.00 | 17.80 | 9.30 | 18.64 | 307.00 | 197.50 |
May | 22.34 | 30-MAY-17:00 | 27.80 | 20.00 | 4.10 | 21.96 | 97.50 | 79.50 |
June | 24.32 | 23-JUN-11:39 | 31.13 | 21.87 | 4.83 | 22.98 | 338.17 | 565.17 |
July | 25.06 | 07-JUL-11:00 | 33.30 | 22.20 | 3.60 | 20.75 | 116.50 | 900.00 |
August | 25.13 | 19-AUG-16:00 | 30.00 | 23.30 | 3.10 | 23.66 | 197.00 | 136.50 |
September | 24.10 | 09-SEP-10:00 | 30.60 | 21.70 | 2.60 | 21.27 | 236.00 | 482.00 |
October | 23.20 | 18-OCT-15:00 | 25.60 | 22.20 | 5.70 | 23.82 | 159.00 | 2.00 |
November | 18.88 | 19-NOV-14:00 | 24.40 | 16.10 | 8.20 | 13.91 | 143.00 | 384.50 |
December | 17.57 | 13-DEC-10:00 | 19.40 | 16.70 | 4.60 | 14.47 | 227.50 | 77.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 15.81 | 17.20 | 13.85 | 2.60 | 13.91 | 0.00 | 0.00 | |
Maximum of Months | 25.13 | 33.30 | 23.30 | 9.30 | 23.82 | 338.17 | 900.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 15.60 | 19-JAN-17:00 | 17.20 | 16.13 | 6.70 | 14.10 | 0.00 | 0.00 |
February | 15.00 | 18-FEB-16:19 | 17.20 | 15.81 | 5.53 | 13.91 | 50.33 | 1.00 |
March | 16.10 | 31-MAR-10:00 | 21.70 | 18.06 | 13.90 | 18.64 | 268.00 | 8.00 |
April | 17.80 | 04-APR-09:20 | 20.77 | 18.74 | 7.53 | 16.79 | 242.00 | 111.50 |
May | 20.60 | 30-MAY-19:00 | 25.00 | 21.79 | 2.60 | 12.41 | 0.00 | 0.00 |
June | 22.80 | 18-JUN-16:00 | 28.30 | 24.23 | 0.00 | 24.66 | 140.50 | 115.50 |
July | 23.30 | 26-JUL-09:00 | 26.10 | 24.10 | 3.60 | 24.66 | 338.00 | 251.50 |
August | 23.90 | 08-AUG-19:00 | 26.10 | 24.51 | 1.50 | 24.83 | 0.00 | 0.00 |
September | 23.30 | 16-SEP-16:00 | 25.60 | 23.89 | 2.10 | 22.13 | 108.00 | 57.50 |
October | 22.20 | 18-OCT-14:00 | 25.00 | 23.04 | 4.60 | 23.32 | 234.50 | 2.00 |
November | 17.20 | 04-NOV-13:00 | 17.80 | 17.48 | 3.60 | 15.02 | 276.50 | 2.50 |
December | 16.70 | 13-DEC-16:19 | 17.03 | 16.82 | 2.93 | 14.10 | 54.00 | 4.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 15.00 | 17.03 | 15.81 | 0.00 | 12.41 | 0.00 | 0.00 | |
Maximum of Months | 23.90 | 28.30 | 24.51 | 13.90 | 24.83 | 338.00 | 251.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 13.74 | 22.89 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 13.65 | 27.55 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 15.17 | 38.46 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 17.98 | 47.59 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 21.32 | 52.44 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 24.28 | 55.84 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 26.07 | 52.33 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 26.20 | 48.31 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 24.63 | 36.35 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 21.78 | 31.91 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 18.45 | 24.33 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 15.51 | 20.76 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 19.94 | 38.29 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 13.65 | 20.76 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 26.20 | 55.84 | 0.00 |
Report: WaterHeaterReportMonthly
For: SWH BOOSTER E WATER HEATER
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.770844E+10 | -0.754278E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -165668325.9 | 81.21 | 0.00 | 0.00 |
February | 0.696523E+10 | -0.681596E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -149270020.4 | 81.21 | 0.00 | 0.00 |
March | 0.770611E+10 | -0.754147E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -164638711.0 | 81.21 | 0.00 | 0.00 |
April | 0.746763E+10 | -0.730860E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -159030936.8 | 81.21 | 0.00 | 0.00 |
May | 0.770684E+10 | -0.754280E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -164044799.8 | 81.21 | 0.00 | 0.00 |
June | 0.745908E+10 | -0.730053E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -158544760.3 | 81.21 | 0.00 | 0.00 |
July | 0.771467E+10 | -0.755086E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -163811112.9 | 81.21 | 0.00 | 0.00 |
August | 0.770658E+10 | -0.754281E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -163771118.4 | 81.21 | 0.00 | 0.00 |
September | 0.746869E+10 | -0.730993E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -158752088.2 | 81.21 | 0.00 | 0.00 |
October | 0.770596E+10 | -0.754144E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -164520496.8 | 81.21 | 0.00 | 0.00 |
November | 0.745198E+10 | -0.729243E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -159555323.8 | 81.21 | 0.00 | 0.00 |
December | 0.771616E+10 | -0.755085E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -165312410.7 | 81.21 | 0.00 | 0.00 |
Annual Sum or Average | 0.907774E+11 | -0.888405E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.193692E+10 | 81.21 | 0.00 | 0.00 |
Minimum of Months | 0.696523E+10 | -0.755086E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -165668325.9 | 81.21 | 0.00 | 0.00 |
Maximum of Months | 0.771616E+10 | -0.681596E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -149270020.4 | 81.21 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: SWH LAUNDRY G WATER HEATER
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.116120E+12 | -0.114306E+12 | 0.00 | 0.00 | 744.00 | 0.00 | -0.181425E+10 | 81.26 | 0.00 | 0.00 |
February | 0.105023E+12 | -0.103383E+12 | 0.00 | 0.00 | 672.00 | 0.00 | -0.163973E+10 | 81.26 | 0.00 | 0.00 |
March | 0.113693E+12 | -0.111877E+12 | 0.00 | 0.00 | 744.00 | 0.00 | -0.181648E+10 | 81.26 | 0.00 | 0.00 |
April | 0.105413E+12 | -0.103652E+12 | 0.00 | 0.00 | 720.00 | 0.00 | -0.176014E+10 | 81.26 | 0.00 | 0.00 |
May | 0.103265E+12 | -0.101447E+12 | 0.00 | 0.00 | 744.00 | 0.00 | -0.181736E+10 | 81.25 | 0.00 | 0.00 |
June | 0.950672E+11 | -0.933103E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -0.175692E+10 | 81.25 | 0.00 | 0.00 |
July | 0.952018E+11 | -0.933871E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.181473E+10 | 81.25 | 0.00 | 0.00 |
August | 0.949843E+11 | -0.931722E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.181209E+10 | 81.25 | 0.00 | 0.00 |
September | 0.944958E+11 | -0.927473E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -0.174848E+10 | 81.25 | 0.00 | 0.00 |
October | 0.102459E+12 | -0.100657E+12 | 0.00 | 0.00 | 744.00 | 0.00 | -0.180181E+10 | 81.25 | 0.00 | 0.00 |
November | 0.104630E+12 | -0.102890E+12 | 0.00 | 0.00 | 720.00 | 0.00 | -0.174042E+10 | 81.25 | 0.00 | 0.00 |
December | 0.113112E+12 | -0.111304E+12 | 0.00 | 0.00 | 744.00 | 0.00 | -0.180783E+10 | 81.26 | 0.00 | 0.00 |
Annual Sum or Average | 0.124346E+13 | -0.122213E+13 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.213302E+11 | 81.25 | 0.00 | 0.00 |
Minimum of Months | 0.944958E+11 | -0.114306E+12 | 0.00 | 0.00 | 672.00 | 0.00 | -0.181736E+10 | 81.25 | 0.00 | 0.00 |
Maximum of Months | 0.116120E+12 | -0.927473E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.163973E+10 | 81.26 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: SWHSYS1 WATER HEATER
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.676821E+11 | -0.660981E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.158402E+10 | 58.98 | 0.00 | 0.00 |
February | 0.612650E+11 | -0.598328E+11 | 0.00 | 0.00 | 672.00 | 0.00 | -0.143221E+10 | 58.98 | 0.00 | 0.00 |
March | 0.656549E+11 | -0.640677E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.158717E+10 | 58.98 | 0.00 | 0.00 |
April | 0.595293E+11 | -0.579900E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -0.153926E+10 | 58.98 | 0.00 | 0.00 |
May | 0.566398E+11 | -0.550511E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.158864E+10 | 58.98 | 0.00 | 0.00 |
June | 0.506292E+11 | -0.490942E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -0.153500E+10 | 58.98 | 0.00 | 0.00 |
July | 0.496507E+11 | -0.480657E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.158497E+10 | 58.98 | 0.00 | 0.00 |
August | 0.495108E+11 | -0.479295E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.158133E+10 | 58.98 | 0.00 | 0.00 |
September | 0.501090E+11 | -0.485856E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -0.152336E+10 | 58.98 | 0.00 | 0.00 |
October | 0.559049E+11 | -0.543377E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.156720E+10 | 58.98 | 0.00 | 0.00 |
November | 0.588211E+11 | -0.573091E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -0.151204E+10 | 58.98 | 0.00 | 0.00 |
December | 0.650875E+11 | -0.635124E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.157510E+10 | 58.98 | 0.00 | 0.00 |
Annual Sum or Average | 0.690484E+12 | -0.671874E+12 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.186103E+11 | 58.98 | 0.00 | 0.00 |
Minimum of Months | 0.495108E+11 | -0.660981E+11 | 0.00 | 0.00 | 672.00 | 0.00 | -0.158864E+10 | 58.98 | 0.00 | 0.00 |
Maximum of Months | 0.676821E+11 | -0.479295E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -0.143221E+10 | 58.98 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
January | 290.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 263.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 351.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 369.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 407.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 411.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 411.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 390.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 298.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 293.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 299.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 285.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 4071.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 263.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 411.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: VAV WITH REHEAT HEATING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.158423E+11 | 73047.43 | 14-JAN-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.136505E+11 | 130225.31 | 12-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.257998E+09 | 17546.65 | 24-MAR-09:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.218074E+09 | 63496.13 | 08-APR-13:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.221117E+09 | 65409.90 | 13-MAY-12:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 54246830.35 | 61843.66 | 08-JUN-11:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 24346685.28 | 8881.71 | 13-SEP-16:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.146463E+09 | 37730.95 | 11-OCT-17:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.606220E+09 | 38206.56 | 22-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.262470E+10 | 61408.68 | 18-DEC-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.336460E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.158423E+11 | 130225.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: BASEMENT VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.604740E+10 | 8840.54 | 30-JAN-11:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.915558E+10 | 9339.05 | 26-FEB-11:35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.148574E+11 | 9357.85 | 30-MAR-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.185452E+11 | 9474.28 | 19-APR-18:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.163301E+11 | 9520.76 | 13-MAY-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.107974E+11 | 9514.40 | 13-JUN-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.812375E+10 | 9558.26 | 08-JUL-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.477493E+10 | 9524.59 | 18-AUG-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.961815E+09 | 6474.57 | 25-SEP-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 82931076.89 | 5526.94 | 10-OCT-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 306758.58 | 170.48 | 05-NOV-16:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.739471E+09 | 4849.39 | 12-DEC-11:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.904163E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 306758.58 | 170.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.185452E+11 | 9558.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: RETAIL_1_FLR_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.549526E+10 | 3222.85 | 09-JAN-01:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.414416E+10 | 3221.76 | 04-FEB-04:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.299106E+10 | 2635.48 | 18-MAR-06:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.237719E+10 | 2685.04 | 06-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.176734E+10 | 1934.63 | 11-MAY-06:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.936096E+09 | 1571.37 | 10-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.749727E+09 | 1550.96 | 28-JUL-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.470319E+09 | 1126.44 | 31-AUG-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.130374E+10 | 1928.13 | 30-SEP-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.247678E+10 | 2550.35 | 26-OCT-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.330271E+10 | 3200.87 | 21-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.457007E+10 | 3222.40 | 01-DEC-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.305845E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.470319E+09 | 1126.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.549526E+10 | 3222.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: RETAIL_2_FLR_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.207632E+10 | 1514.40 | 08-JAN-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.155708E+10 | 1377.31 | 13-FEB-11:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.109058E+10 | 1322.85 | 23-MAR-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.825125E+09 | 1332.40 | 06-APR-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.642596E+09 | 1205.08 | 13-MAY-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.419726E+09 | 1099.62 | 08-JUN-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.395020E+09 | 1031.23 | 03-JUL-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.320658E+09 | 972.30 | 08-AUG-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.506107E+09 | 1085.54 | 22-SEP-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.924609E+09 | 1283.96 | 31-OCT-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.121565E+10 | 1232.92 | 22-NOV-11:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.171883E+10 | 1280.15 | 18-DEC-11:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.116923E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.320658E+09 | 972.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.207632E+10 | 1514.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: MECH_FLR_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.420441E+10 | 2199.18 | 27-JAN-11:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.316288E+10 | 2196.73 | 13-FEB-11:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.235657E+10 | 1878.05 | 19-MAR-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.170923E+10 | 1780.39 | 06-APR-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.110800E+10 | 1439.10 | 13-MAY-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.458854E+09 | 1166.09 | 08-JUN-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.346147E+09 | 1081.72 | 29-JUL-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.281208E+09 | 912.53 | 26-AUG-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.871403E+09 | 1211.95 | 15-SEP-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.195696E+10 | 1715.17 | 26-OCT-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.257359E+10 | 1988.97 | 22-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.350491E+10 | 2156.30 | 18-DEC-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.225342E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.281208E+09 | 912.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.420441E+10 | 2199.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: STORAGE_FLR_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.258985E+10 | 1229.13 | 27-JAN-11:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.197008E+10 | 1234.50 | 05-FEB-11:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.151825E+10 | 1075.92 | 19-MAR-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.111524E+10 | 1017.36 | 06-APR-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.726371E+09 | 777.86 | 11-MAY-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.294445E+09 | 648.71 | 08-JUN-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.214304E+09 | 589.04 | 29-JUL-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.170228E+09 | 476.66 | 28-AUG-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.582698E+09 | 666.93 | 30-SEP-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.127469E+10 | 968.24 | 26-OCT-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.165224E+10 | 1123.02 | 22-NOV-04:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.220037E+10 | 1221.88 | 18-DEC-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.143088E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.170228E+09 | 476.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.258985E+10 | 1234.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: LAUNDRY_FLR_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.145209E+11 | 12920.19 | 09-JAN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.125452E+11 | 12918.54 | 04-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.130391E+11 | 12318.37 | 30-MAR-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.126608E+11 | 13469.36 | 15-APR-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.130513E+11 | 13581.11 | 13-MAY-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.127613E+11 | 13572.14 | 13-JUN-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.133685E+11 | 13634.72 | 08-JUL-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.132516E+11 | 13607.38 | 19-AUG-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.124753E+11 | 13552.70 | 09-SEP-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.130176E+11 | 13116.67 | 10-OCT-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.127380E+11 | 12540.42 | 22-NOV-04:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.138783E+11 | 12919.15 | 04-DEC-04:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.157308E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.124753E+11 | 12318.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.145209E+11 | 13634.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CAFE_FLR_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.100293E+11 | 10092.18 | 10-JAN-09:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.720393E+10 | 9253.00 | 01-FEB-11:25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.450140E+10 | 8404.23 | 22-MAR-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.368591E+10 | 7649.74 | 06-APR-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.286882E+10 | 6357.95 | 24-MAY-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.182721E+10 | 6276.76 | 08-JUN-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.157014E+10 | 6164.44 | 28-JUL-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.106088E+10 | 5163.24 | 31-AUG-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.198351E+10 | 6882.82 | 29-SEP-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.354126E+10 | 8336.11 | 30-OCT-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.494935E+10 | 8258.89 | 30-NOV-11:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.771713E+10 | 8417.59 | 01-DEC-07:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.509388E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.106088E+10 | 5163.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.100293E+11 | 10092.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: LOBBY_FLR_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.248045E+11 | 26079.14 | 08-JAN-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.180363E+11 | 24271.47 | 06-FEB-11:15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.124027E+11 | 21622.45 | 22-MAR-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.102378E+11 | 21540.86 | 06-APR-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.866049E+10 | 20416.36 | 11-MAY-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.610120E+10 | 19712.41 | 08-JUN-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.566293E+10 | 18347.59 | 03-JUL-10:35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.439427E+10 | 16782.11 | 01-AUG-10:35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.607133E+10 | 18736.62 | 29-SEP-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.968797E+10 | 21544.67 | 30-OCT-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.126792E+11 | 21137.60 | 30-NOV-11:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.191231E+11 | 22185.69 | 25-DEC-15:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.137862E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.439427E+10 | 16782.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.248045E+11 | 26079.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CORRIDOR_FLR_3 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.164098E+11 | 11043.19 | 08-JAN-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.110754E+11 | 11038.71 | 12-FEB-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.509346E+10 | 7921.06 | 22-MAR-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.215695E+10 | 6671.03 | 06-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.336614E+09 | 4006.98 | 11-MAY-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.184478E+09 | 4096.14 | 30-SEP-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.333548E+10 | 7433.49 | 30-OCT-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.691251E+10 | 8736.28 | 22-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.125217E+11 | 9360.69 | 18-DEC-07:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.580263E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.164098E+11 | 11043.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CORRIDOR_FLR_6 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.135820E+11 | 7372.92 | 09-JAN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.991248E+10 | 7370.47 | 04-FEB-04:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.666258E+10 | 6076.25 | 19-MAR-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.433258E+10 | 5883.65 | 06-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.219524E+10 | 3878.90 | 11-MAY-06:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.537845E+09 | 2763.37 | 08-JUN-06:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.345439E+09 | 2486.29 | 28-JUL-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 80661261.44 | 1572.72 | 31-AUG-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.180391E+10 | 3472.39 | 30-SEP-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.543640E+10 | 5721.49 | 26-OCT-06:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.795670E+10 | 7171.72 | 22-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.112453E+11 | 7371.10 | 04-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.640912E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 80661261.44 | 1572.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.135820E+11 | 7372.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: BANQUET_FLR_6 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.580265E+10 | 8496.53 | 27-JAN-11:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.401555E+10 | 8479.87 | 03-FEB-11:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.229263E+10 | 7458.16 | 20-MAR-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.125934E+10 | 7538.69 | 06-APR-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.639086E+09 | 6041.23 | 11-MAY-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.307804E+09 | 5433.01 | 08-JUN-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.268534E+09 | 5209.07 | 25-JUL-10:35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.285308E+09 | 5186.43 | 28-AUG-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.668811E+09 | 6123.32 | 25-SEP-10:35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.190658E+10 | 7626.13 | 26-OCT-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.284932E+10 | 7532.79 | 21-NOV-11:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.437070E+10 | 7797.55 | 18-DEC-11:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.246663E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.268534E+09 | 5186.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.580265E+10 | 8496.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: DINING_FLR_6 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.514450E+10 | 8071.58 | 27-JAN-11:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.345562E+10 | 8055.67 | 03-FEB-11:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.175552E+10 | 7073.71 | 20-MAR-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.857072E+09 | 7054.06 | 06-APR-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.355385E+09 | 5466.70 | 11-MAY-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.172620E+09 | 4918.85 | 08-JUN-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.152429E+09 | 4657.73 | 25-JUL-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.164334E+09 | 4714.12 | 28-AUG-10:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.381321E+09 | 5681.37 | 25-SEP-10:35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.141709E+10 | 7212.08 | 26-OCT-10:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.229291E+10 | 7067.88 | 21-NOV-11:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.375073E+10 | 7401.19 | 04-DEC-11:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.198995E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.152429E+09 | 4657.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.514450E+10 | 8071.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: KITCHEN_FLR_6 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.265623E+10 | 7077.02 | 08-JAN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.198023E+10 | 7489.10 | 12-FEB-03:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.140051E+10 | 4991.16 | 23-MAR-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.102412E+10 | 5146.84 | 06-APR-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.680237E+09 | 3624.23 | 11-MAY-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.344708E+09 | 2951.38 | 08-JUN-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.246248E+09 | 2559.28 | 29-JUL-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.192262E+09 | 1765.99 | 25-AUG-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.503071E+09 | 3475.16 | 29-SEP-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.115654E+10 | 4991.04 | 26-OCT-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.165847E+10 | 6003.02 | 22-NOV-03:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.221667E+10 | 6385.79 | 18-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.140593E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.192262E+09 | 1765.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.265623E+10 | 7489.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: FLR_3_DOAS HEATING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.236652E+10 | 6946.46 | 07-JAN-19:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.151622E+10 | 10946.91 | 12-FEB-08:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 9828.15 | 0.35 | 17-MAR-17:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 16300.08 | 0.36 | 24-APR-02:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 16049.72 | 0.35 | 22-MAY-10:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 12994.82 | 0.36 | 01-JUN-20:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 10403.82 | 0.35 | 24-JUL-22:57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 9160.79 | 0.36 | 30-AUG-22:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 15856.84 | 0.35 | 20-SEP-15:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 8592.93 | 0.36 | 18-OCT-23:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 85031500.69 | 2559.95 | 22-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.300946E+09 | 4411.37 | 18-DEC-08:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.426882E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 8592.93 | 0.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.236652E+10 | 10946.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_1_FLR_3 FAN COIL HEATING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.447837E+10 | 6836.61 | 18-JAN-09:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.269156E+10 | 6836.36 | 07-FEB-19:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.680272E+09 | 6799.94 | 23-MAR-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.220402E+09 | 6760.28 | 06-APR-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 11602913.14 | 2574.05 | 05-MAY-08:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 4975412.76 | 2934.55 | 06-JUN-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 4546972.42 | 2328.07 | 02-JUL-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 4492147.91 | 3106.45 | 26-AUG-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 14433003.87 | 2458.45 | 15-SEP-08:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.423394E+09 | 6762.23 | 31-OCT-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.118629E+10 | 6836.47 | 30-NOV-16:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.286441E+10 | 6835.76 | 31-DEC-16:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.125847E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 4492147.91 | 2328.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.447837E+10 | 6836.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_2_FLR_3 FAN COIL HEATING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.550131E+10 | 6830.18 | 18-JAN-16:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.332578E+10 | 6829.25 | 08-FEB-09:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.904813E+09 | 6800.06 | 23-MAR-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.267210E+09 | 6776.36 | 06-APR-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 14326459.27 | 2567.95 | 05-MAY-08:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 5047645.29 | 3430.29 | 04-JUN-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 3946253.98 | 2662.33 | 02-JUL-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 4592933.75 | 3741.40 | 26-AUG-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 15632155.90 | 2683.30 | 23-SEP-08:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.582868E+09 | 6826.06 | 26-OCT-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.168698E+10 | 6828.69 | 30-NOV-16:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.371933E+10 | 6828.03 | 07-DEC-09:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.160318E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 3946253.98 | 2567.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.550131E+10 | 6830.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_3_MULT19_FLR_3 FAN COIL HEATING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.310237E+10 | 20336.29 | 08-JAN-05:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.750870E+09 | 20546.43 | 12-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 11548724.37 | 2154.27 | 26-DEC-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.386479E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.310237E+10 | 20546.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_4_MULT19_FLR_3 FAN COIL HEATING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.165842E+11 | 40210.10 | 07-JAN-16:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.942877E+10 | 40200.80 | 03-FEB-16:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.827681E+09 | 38522.45 | 22-MAR-15:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.284109E+09 | 31081.10 | 26-APR-15:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 45641321.81 | 23703.53 | 18-MAY-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 17899487.93 | 22482.01 | 02-JUN-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 13429066.79 | 18703.31 | 11-JUL-08:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 11253346.74 | 20012.52 | 25-AUG-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 56348108.24 | 26492.63 | 23-SEP-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.293851E+09 | 38407.84 | 26-OCT-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.228478E+10 | 39017.28 | 22-NOV-16:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.771022E+10 | 39392.38 | 03-DEC-16:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.375582E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 11253346.74 | 18703.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.165842E+11 | 40210.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_5_FLR_3 FAN COIL HEATING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.453036E+10 | 6660.11 | 18-JAN-16:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.266024E+10 | 6659.34 | 08-FEB-09:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.692217E+09 | 6618.76 | 22-MAR-15:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.228352E+09 | 3293.99 | 02-APR-18:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 14680083.36 | 2893.17 | 10-MAY-15:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 454581.53 | 1942.84 | 18-JUN-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 1322912.44 | 2145.79 | 30-JUL-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 591578.87 | 2137.85 | 24-AUG-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 12232539.44 | 2443.88 | 17-SEP-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.442120E+09 | 6587.08 | 31-OCT-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.117654E+10 | 6658.69 | 30-NOV-16:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.284116E+10 | 6657.96 | 31-DEC-16:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.126003E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 454581.53 | 1942.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.453036E+10 | 6660.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_6_FLR_3 FAN COIL HEATING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.554189E+10 | 6654.60 | 18-JAN-16:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.326876E+10 | 6653.71 | 08-FEB-09:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.900186E+09 | 6639.01 | 22-MAR-15:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.275200E+09 | 3627.09 | 04-APR-18:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 17692813.50 | 2350.42 | 10-MAY-15:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 373493.38 | 1979.45 | 18-JUN-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 1305663.62 | 2173.35 | 30-JUL-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 588768.57 | 2125.21 | 24-AUG-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 14549500.23 | 2461.85 | 17-SEP-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.604419E+09 | 6584.40 | 31-OCT-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.164630E+10 | 6653.06 | 30-NOV-16:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.369248E+10 | 6652.33 | 31-DEC-16:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.159637E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 373493.38 | 1979.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.554189E+10 | 6654.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_1_FLR_6 FAN COIL HEATING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.159837E+10 | 2036.21 | 18-JAN-16:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.980240E+09 | 2036.28 | 08-FEB-09:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.284308E+09 | 2035.84 | 23-MAR-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 95952548.81 | 2034.99 | 06-APR-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 7314418.46 | 869.91 | 14-MAY-08:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 1228772.21 | 749.84 | 06-JUN-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 995065.62 | 654.26 | 11-JUL-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 996075.55 | 813.02 | 26-AUG-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 6542739.39 | 781.17 | 23-SEP-08:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.185096E+09 | 2036.34 | 31-OCT-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.479372E+09 | 2035.93 | 30-NOV-19:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.108101E+10 | 2036.06 | 31-DEC-09:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.472143E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 995065.62 | 654.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.159837E+10 | 2036.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_2_FLR_6 FAN COIL HEATING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.190589E+10 | 2033.77 | 01-JAN-16:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.117888E+10 | 2033.56 | 08-FEB-09:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.358596E+09 | 2033.12 | 23-MAR-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.112367E+09 | 2032.27 | 06-APR-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 8581365.22 | 876.52 | 14-MAY-08:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 1231083.55 | 782.26 | 06-JUN-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 874140.82 | 599.70 | 02-JUL-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 1016458.32 | 880.71 | 26-AUG-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 7680064.04 | 848.10 | 10-SEP-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.244102E+09 | 2033.63 | 31-OCT-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.647748E+09 | 2033.21 | 30-NOV-19:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.134817E+10 | 2033.69 | 06-DEC-16:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.581514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 874140.82 | 599.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.190589E+10 | 2033.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_3_MULT9_FLR_6 FAN COIL HEATING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.461325E+10 | 9642.89 | 03-JAN-09:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.272837E+10 | 9644.64 | 07-FEB-19:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.638898E+09 | 9530.29 | 22-MAR-15:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.275612E+09 | 9481.22 | 06-APR-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 17533898.28 | 3204.82 | 05-MAY-08:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 6402944.84 | 4674.89 | 06-JUN-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 4753814.11 | 3395.95 | 12-JUL-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 3685295.94 | 3318.69 | 09-AUG-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 13643760.79 | 3843.97 | 14-SEP-08:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.334517E+09 | 9458.92 | 31-OCT-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.916391E+09 | 9635.68 | 30-NOV-16:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.256497E+10 | 9641.82 | 25-DEC-16:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.121180E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 3685295.94 | 3204.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.461325E+10 | 9644.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: VAV WITH REHEAT COOLING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.206885E+11 | 0.162733E+11 | 243323.81 | 19-JAN-19:05 | 118382.16 | 0.05 |
February | 0.00 | 0.00 | 0.619588E+11 | 0.592234E+11 | 268537.31 | 28-FEB-17:10 | 268537.31 | 0.11 |
March | 0.00 | 0.00 | 0.172776E+12 | 0.162748E+12 | 349050.94 | 30-MAR-10:40 | 238443.06 | 0.28 |
April | 0.00 | 0.00 | 0.337422E+12 | 0.284413E+12 | 448744.67 | 22-APR-17:17 | 227443.31 | 0.64 |
May | 0.00 | 0.00 | 0.654340E+12 | 0.457116E+12 | 584775.79 | 30-MAY-22:00 | 224912.59 | 0.90 |
June | 0.00 | 0.00 | 0.958015E+12 | 0.609792E+12 | 651558.35 | 17-JUN-21:00 | 225302.48 | 0.92 |
July | 0.00 | 0.00 | 0.122052E+13 | 0.683322E+12 | 689391.02 | 29-JUL-19:20 | 229190.63 | 1.00 |
August | 0.00 | 0.00 | 0.127288E+13 | 0.705390E+12 | 656645.02 | 20-AUG-10:35 | 300488.90 | 1.00 |
September | 0.00 | 0.00 | 0.831474E+12 | 0.523115E+12 | 630496.78 | 09-SEP-10:35 | 337629.43 | 0.98 |
October | 0.00 | 0.00 | 0.358318E+12 | 0.240977E+12 | 634587.27 | 19-OCT-04:20 | 206769.50 | 0.51 |
November | 0.00 | 0.00 | 0.142871E+12 | 0.113170E+12 | 420629.27 | 27-NOV-19:05 | 224300.45 | 0.25 |
December | 0.00 | 0.00 | 0.351406E+11 | 0.285739E+11 | 361394.06 | 13-DEC-11:40 | 191531.55 | 0.08 |
Annual Sum or Average | 0.00 | 0.00 | 0.606640E+13 | 0.388411E+13 | 0.56 | |||
Minimum of Months | 0.00 | 0.00 | 0.206885E+11 | 0.162733E+11 | 243323.81 | 118382.16 | 0.05 | |
Maximum of Months | 0.00 | 0.00 | 0.127288E+13 | 0.705390E+12 | 689391.02 | 337629.43 | 1.00 |
Report: CoilReportMonthly
For: FLR_3_DOAS COOLING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.176252E+10 | 0.137197E+10 | 23359.34 | 19-JAN-16:00 | 14579.82 | 0.05 |
February | 0.00 | 0.00 | 0.553442E+10 | 0.547982E+10 | 27771.79 | 28-FEB-15:00 | 27771.79 | 0.06 |
March | 0.00 | 0.00 | 0.173955E+11 | 0.157534E+11 | 42240.28 | 31-MAR-11:00 | 23978.20 | 0.26 |
April | 0.00 | 0.00 | 0.355080E+11 | 0.290149E+11 | 52592.95 | 04-APR-10:50 | 26043.18 | 0.59 |
May | 0.00 | 0.00 | 0.702642E+11 | 0.481776E+11 | 61735.65 | 23-MAY-14:00 | 26801.33 | 0.89 |
June | 0.00 | 0.00 | 0.102458E+12 | 0.650665E+11 | 71662.73 | 26-JUN-18:00 | 28106.36 | 0.92 |
July | 0.00 | 0.00 | 0.129170E+12 | 0.725090E+11 | 79586.62 | 26-JUL-07:25 | 26825.53 | 1.00 |
August | 0.00 | 0.00 | 0.131783E+12 | 0.752888E+11 | 78977.54 | 05-AUG-07:40 | 27758.63 | 1.00 |
September | 0.00 | 0.00 | 0.921407E+11 | 0.567250E+11 | 69655.32 | 28-SEP-12:10 | 26419.43 | 0.97 |
October | 0.00 | 0.00 | 0.382673E+11 | 0.249070E+11 | 74182.51 | 19-OCT-02:30 | 24824.60 | 0.47 |
November | 0.00 | 0.00 | 0.148105E+11 | 0.110295E+11 | 46083.91 | 19-NOV-23:57 | 22548.51 | 0.21 |
December | 0.00 | 0.00 | 0.325640E+10 | 0.254138E+10 | 35337.19 | 13-DEC-13:00 | 20785.21 | 0.07 |
Annual Sum or Average | 0.00 | 0.00 | 0.642351E+12 | 0.407865E+12 | 0.54 | |||
Minimum of Months | 0.00 | 0.00 | 0.176252E+10 | 0.137197E+10 | 23359.34 | 14579.82 | 0.05 | |
Maximum of Months | 0.00 | 0.00 | 0.131783E+12 | 0.752888E+11 | 79586.62 | 28106.36 | 1.00 |
Report: CoilReportMonthly
For: ROOM_1_FLR_3 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 97789098.46 | 77786337.49 | 15495.26 | 29-JAN-16:01 | 15495.26 | 0.02 |
February | 0.00 | 0.00 | 0.622339E+09 | 0.588356E+09 | 15523.30 | 28-FEB-16:01 | 15523.30 | 0.03 |
March | 0.00 | 0.00 | 0.240639E+10 | 0.167756E+10 | 16364.75 | 28-MAR-15:02 | 13744.89 | 0.26 |
April | 0.00 | 0.00 | 0.428488E+10 | 0.258463E+10 | 17601.92 | 04-APR-15:01 | 13524.36 | 0.59 |
May | 0.00 | 0.00 | 0.695304E+10 | 0.378562E+10 | 18139.18 | 28-MAY-08:62 | 12297.36 | 0.81 |
June | 0.00 | 0.00 | 0.102841E+11 | 0.597279E+10 | 20148.28 | 29-JUN-08:62 | 12142.82 | 0.91 |
July | 0.00 | 0.00 | 0.121877E+11 | 0.706203E+10 | 20066.31 | 30-JUL-08:62 | 11397.09 | 0.92 |
August | 0.00 | 0.00 | 0.130542E+11 | 0.757532E+10 | 19913.94 | 29-AUG-08:62 | 12134.04 | 0.94 |
September | 0.00 | 0.00 | 0.795416E+10 | 0.418922E+10 | 19885.77 | 17-SEP-08:62 | 11910.69 | 0.86 |
October | 0.00 | 0.00 | 0.351496E+10 | 0.192629E+10 | 19449.67 | 18-OCT-15:02 | 12530.77 | 0.51 |
November | 0.00 | 0.00 | 0.115743E+10 | 0.777775E+09 | 17019.11 | 19-NOV-16:02 | 13615.70 | 0.17 |
December | 0.00 | 0.00 | 0.269327E+09 | 0.170363E+09 | 15643.11 | 12-DEC-16:02 | 13820.57 | 0.05 |
Annual Sum or Average | 0.00 | 0.00 | 0.627863E+11 | 0.363877E+11 | 0.51 | |||
Minimum of Months | 0.00 | 0.00 | 97789098.46 | 77786337.49 | 15495.26 | 11397.09 | 0.02 | |
Maximum of Months | 0.00 | 0.00 | 0.130542E+11 | 0.757532E+10 | 20148.28 | 15523.30 | 0.94 |
Report: CoilReportMonthly
For: ROOM_2_FLR_3 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 9780428.22 | 5270602.69 | 6920.84 | 29-JAN-16:01 | 6920.84 | 0.01 |
February | 0.00 | 0.00 | 0.303224E+09 | 0.284464E+09 | 15353.49 | 28-FEB-16:01 | 15353.49 | 0.02 |
March | 0.00 | 0.00 | 0.163807E+10 | 0.105900E+10 | 16091.12 | 29-MAR-15:02 | 14074.93 | 0.22 |
April | 0.00 | 0.00 | 0.362209E+10 | 0.210328E+10 | 17342.47 | 04-APR-15:01 | 13267.54 | 0.55 |
May | 0.00 | 0.00 | 0.662543E+10 | 0.357559E+10 | 17979.56 | 28-MAY-08:62 | 12163.03 | 0.79 |
June | 0.00 | 0.00 | 0.102198E+11 | 0.597450E+10 | 19889.45 | 29-JUN-08:62 | 12035.58 | 0.91 |
July | 0.00 | 0.00 | 0.120336E+11 | 0.698804E+10 | 19943.78 | 27-JUL-08:62 | 11199.53 | 0.92 |
August | 0.00 | 0.00 | 0.124146E+11 | 0.707718E+10 | 19540.75 | 24-AUG-08:62 | 11869.34 | 0.94 |
September | 0.00 | 0.00 | 0.694042E+10 | 0.348380E+10 | 19674.06 | 17-SEP-08:62 | 11735.32 | 0.83 |
October | 0.00 | 0.00 | 0.236365E+10 | 0.118797E+10 | 19253.80 | 18-OCT-15:02 | 12386.12 | 0.39 |
November | 0.00 | 0.00 | 0.520211E+09 | 0.281858E+09 | 16983.55 | 05-NOV-15:02 | 13610.04 | 0.11 |
December | 0.00 | 0.00 | 62905346.47 | 26365744.93 | 14631.42 | 11-DEC-16:02 | 13534.23 | 0.03 |
Annual Sum or Average | 0.00 | 0.00 | 0.567537E+11 | 0.320473E+11 | 0.48 | |||
Minimum of Months | 0.00 | 0.00 | 9780428.22 | 5270602.69 | 6920.84 | 6920.84 | 0.01 | |
Maximum of Months | 0.00 | 0.00 | 0.124146E+11 | 0.707718E+10 | 19943.78 | 15353.49 | 0.94 |
Report: CoilReportMonthly
For: ROOM_3_MULT19_FLR_3 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.128980E+10 | 0.118804E+10 | 25679.39 | 29-JAN-13:30 | 25679.39 | 0.01 |
February | 0.00 | 0.00 | 0.638017E+10 | 0.625963E+10 | 33285.24 | 26-FEB-14:50 | 33285.24 | 0.01 |
March | 0.00 | 0.00 | 0.148582E+11 | 0.107911E+11 | 35379.51 | 30-MAR-13:30 | 25216.21 | 0.23 |
April | 0.00 | 0.00 | 0.200416E+11 | 0.108434E+11 | 30831.91 | 15-APR-14:00 | 26336.15 | 0.52 |
May | 0.00 | 0.00 | 0.278309E+11 | 0.122362E+11 | 31892.42 | 06-MAY-20:40 | 18047.03 | 0.72 |
June | 0.00 | 0.00 | 0.432443E+11 | 0.213762E+11 | 37608.17 | 25-JUN-19:05 | 26778.57 | 0.89 |
July | 0.00 | 0.00 | 0.530759E+11 | 0.265478E+11 | 46223.93 | 13-JUL-21:00 | 22903.03 | 0.97 |
August | 0.00 | 0.00 | 0.625542E+11 | 0.338721E+11 | 43674.06 | 23-AUG-21:00 | 20475.42 | 1.00 |
September | 0.00 | 0.00 | 0.426910E+11 | 0.226067E+11 | 49014.08 | 24-SEP-14:40 | 38721.03 | 0.86 |
October | 0.00 | 0.00 | 0.277047E+11 | 0.177794E+11 | 49469.81 | 11-OCT-15:13 | 38407.81 | 0.49 |
November | 0.00 | 0.00 | 0.149007E+11 | 0.123791E+11 | 36836.16 | 12-NOV-14:00 | 36836.16 | 0.18 |
December | 0.00 | 0.00 | 0.630885E+10 | 0.533903E+10 | 36362.85 | 12-DEC-12:30 | 25233.28 | 0.06 |
Annual Sum or Average | 0.00 | 0.00 | 0.320880E+12 | 0.181219E+12 | 0.50 | |||
Minimum of Months | 0.00 | 0.00 | 0.128980E+10 | 0.118804E+10 | 25679.39 | 18047.03 | 0.01 | |
Maximum of Months | 0.00 | 0.00 | 0.625542E+11 | 0.338721E+11 | 49469.81 | 38721.03 | 1.00 |
Report: CoilReportMonthly
For: ROOM_4_MULT19_FLR_3 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.240197E+10 | 0.119051E+10 | 92038.06 | 01-JAN-09:02 | 90469.58 | 0.08 |
February | 0.00 | 0.00 | 0.846346E+10 | 0.601487E+10 | 109240.69 | 18-FEB-09:02 | 84628.59 | 0.15 |
March | 0.00 | 0.00 | 0.222262E+11 | 0.149447E+11 | 103106.70 | 30-MAR-08:62 | 72437.71 | 0.33 |
April | 0.00 | 0.00 | 0.395920E+11 | 0.244904E+11 | 116020.51 | 23-APR-08:62 | 79941.93 | 0.56 |
May | 0.00 | 0.00 | 0.622112E+11 | 0.375605E+11 | 119436.17 | 27-MAY-08:62 | 79322.62 | 0.68 |
June | 0.00 | 0.00 | 0.808349E+11 | 0.535260E+11 | 133042.49 | 29-JUN-08:62 | 78066.47 | 0.80 |
July | 0.00 | 0.00 | 0.922895E+11 | 0.597048E+11 | 133356.78 | 27-JUL-08:62 | 72646.83 | 0.84 |
August | 0.00 | 0.00 | 0.920284E+11 | 0.592760E+11 | 129986.61 | 12-AUG-08:62 | 81509.09 | 0.83 |
September | 0.00 | 0.00 | 0.629723E+11 | 0.363969E+11 | 130171.23 | 17-SEP-08:62 | 80324.06 | 0.73 |
October | 0.00 | 0.00 | 0.319075E+11 | 0.167098E+11 | 121326.85 | 18-OCT-08:63 | 75628.49 | 0.61 |
November | 0.00 | 0.00 | 0.151899E+11 | 0.906893E+10 | 112475.42 | 27-NOV-19:03 | 80671.92 | 0.27 |
December | 0.00 | 0.00 | 0.512686E+10 | 0.268561E+10 | 105872.78 | 24-DEC-09:02 | 84565.92 | 0.15 |
Annual Sum or Average | 0.00 | 0.00 | 0.515244E+12 | 0.321569E+12 | 0.50 | |||
Minimum of Months | 0.00 | 0.00 | 0.240197E+10 | 0.119051E+10 | 92038.06 | 72437.71 | 0.08 | |
Maximum of Months | 0.00 | 0.00 | 0.922895E+11 | 0.597048E+11 | 133356.78 | 90469.58 | 0.84 |
Report: CoilReportMonthly
For: ROOM_5_FLR_3 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 65521443.26 | 45265117.51 | 13342.75 | 29-JAN-16:01 | 13342.75 | 0.02 |
February | 0.00 | 0.00 | 0.653139E+09 | 0.619602E+09 | 14028.52 | 28-FEB-16:01 | 14028.52 | 0.03 |
March | 0.00 | 0.00 | 0.204949E+10 | 0.136841E+10 | 15631.51 | 30-MAR-08:62 | 11331.06 | 0.26 |
April | 0.00 | 0.00 | 0.412262E+10 | 0.244400E+10 | 15913.35 | 04-APR-15:01 | 12221.66 | 0.60 |
May | 0.00 | 0.00 | 0.717207E+10 | 0.397242E+10 | 16728.35 | 28-MAY-08:62 | 11566.71 | 0.85 |
June | 0.00 | 0.00 | 0.105195E+11 | 0.611293E+10 | 17820.28 | 23-JUN-08:62 | 11127.48 | 0.95 |
July | 0.00 | 0.00 | 0.126154E+11 | 0.742981E+10 | 18146.43 | 30-JUL-08:62 | 10349.00 | 0.95 |
August | 0.00 | 0.00 | 0.131668E+11 | 0.774251E+10 | 17873.18 | 24-AUG-08:62 | 10790.96 | 0.96 |
September | 0.00 | 0.00 | 0.803586E+10 | 0.432799E+10 | 18008.55 | 17-SEP-08:62 | 10786.09 | 0.88 |
October | 0.00 | 0.00 | 0.343659E+10 | 0.185066E+10 | 17595.29 | 18-OCT-15:02 | 11328.70 | 0.54 |
November | 0.00 | 0.00 | 0.102312E+10 | 0.661525E+09 | 15549.53 | 05-NOV-15:02 | 12424.87 | 0.17 |
December | 0.00 | 0.00 | 0.228530E+09 | 0.130656E+09 | 14043.46 | 12-DEC-16:02 | 12364.28 | 0.05 |
Annual Sum or Average | 0.00 | 0.00 | 0.630887E+11 | 0.367058E+11 | 0.52 | |||
Minimum of Months | 0.00 | 0.00 | 65521443.26 | 45265117.51 | 13342.75 | 10349.00 | 0.02 | |
Maximum of Months | 0.00 | 0.00 | 0.131668E+11 | 0.774251E+10 | 18146.43 | 14028.52 | 0.96 |
Report: CoilReportMonthly
For: ROOM_6_FLR_3 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 8742117.33 | 4419040.87 | 3302.85 | 19-JAN-19:05 | 1020.41 | 0.01 |
February | 0.00 | 0.00 | 0.308724E+09 | 0.287324E+09 | 13604.81 | 28-FEB-16:01 | 13604.81 | 0.02 |
March | 0.00 | 0.00 | 0.126449E+10 | 0.741502E+09 | 15467.03 | 30-MAR-08:62 | 11154.54 | 0.22 |
April | 0.00 | 0.00 | 0.342224E+10 | 0.194679E+10 | 15688.89 | 04-APR-15:01 | 11986.21 | 0.57 |
May | 0.00 | 0.00 | 0.682164E+10 | 0.375638E+10 | 16610.39 | 28-MAY-08:62 | 11458.81 | 0.84 |
June | 0.00 | 0.00 | 0.104511E+11 | 0.609336E+10 | 17669.17 | 23-JUN-08:62 | 11044.05 | 0.95 |
July | 0.00 | 0.00 | 0.124554E+11 | 0.732513E+10 | 18082.00 | 27-JUL-08:62 | 10161.90 | 0.95 |
August | 0.00 | 0.00 | 0.125208E+11 | 0.716435E+10 | 17717.44 | 24-AUG-08:62 | 10663.29 | 0.96 |
September | 0.00 | 0.00 | 0.698959E+10 | 0.358016E+10 | 17853.70 | 17-SEP-08:62 | 10650.94 | 0.87 |
October | 0.00 | 0.00 | 0.224464E+10 | 0.104889E+10 | 17457.19 | 18-OCT-15:02 | 11219.28 | 0.40 |
November | 0.00 | 0.00 | 0.387255E+09 | 0.168945E+09 | 14947.38 | 05-NOV-15:02 | 11645.16 | 0.12 |
December | 0.00 | 0.00 | 45555057.22 | 13965452.53 | 8510.34 | 12-DEC-16:02 | 5585.48 | 0.02 |
Annual Sum or Average | 0.00 | 0.00 | 0.569201E+11 | 0.321312E+11 | 0.50 | |||
Minimum of Months | 0.00 | 0.00 | 8742117.33 | 4419040.87 | 3302.85 | 1020.41 | 0.01 | |
Maximum of Months | 0.00 | 0.00 | 0.125208E+11 | 0.732513E+10 | 18082.00 | 13604.81 | 0.96 |
Report: CoilReportMonthly
For: ROOM_1_FLR_6 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 14536349.02 | 12542332.32 | 4149.95 | 29-JAN-16:01 | 4149.95 | 0.01 |
February | 0.00 | 0.00 | 0.150841E+09 | 0.145204E+09 | 4157.44 | 28-FEB-16:01 | 4157.44 | 0.02 |
March | 0.00 | 0.00 | 0.625971E+09 | 0.442583E+09 | 4426.84 | 28-MAR-15:02 | 3747.20 | 0.25 |
April | 0.00 | 0.00 | 0.119798E+10 | 0.752553E+09 | 4790.97 | 21-APR-18:02 | 3516.42 | 0.58 |
May | 0.00 | 0.00 | 0.200542E+10 | 0.114615E+10 | 5012.17 | 28-MAY-08:62 | 3184.89 | 0.82 |
June | 0.00 | 0.00 | 0.292635E+10 | 0.175902E+10 | 5541.07 | 29-JUN-08:62 | 3167.50 | 0.92 |
July | 0.00 | 0.00 | 0.346147E+10 | 0.208290E+10 | 5580.43 | 30-JUL-08:62 | 2928.33 | 0.93 |
August | 0.00 | 0.00 | 0.367818E+10 | 0.220686E+10 | 5507.59 | 29-AUG-08:62 | 3155.52 | 0.94 |
September | 0.00 | 0.00 | 0.219933E+10 | 0.119701E+10 | 5518.84 | 17-SEP-08:62 | 3086.98 | 0.86 |
October | 0.00 | 0.00 | 0.942790E+09 | 0.537660E+09 | 5045.94 | 18-OCT-15:02 | 3443.18 | 0.47 |
November | 0.00 | 0.00 | 0.276966E+09 | 0.187680E+09 | 4576.36 | 19-NOV-16:02 | 3677.02 | 0.14 |
December | 0.00 | 0.00 | 55259574.57 | 34590674.93 | 4229.96 | 12-DEC-16:02 | 3759.77 | 0.04 |
Annual Sum or Average | 0.00 | 0.00 | 0.175351E+11 | 0.105047E+11 | 0.50 | |||
Minimum of Months | 0.00 | 0.00 | 14536349.02 | 12542332.32 | 4149.95 | 2928.33 | 0.01 | |
Maximum of Months | 0.00 | 0.00 | 0.367818E+10 | 0.220686E+10 | 5580.43 | 4157.44 | 0.94 |
Report: CoilReportMonthly
For: ROOM_2_FLR_6 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 1294287.95 | 826905.34 | 1029.96 | 19-JAN-19:05 | 317.26 | 0.00 |
February | 0.00 | 0.00 | 73614742.03 | 70779331.11 | 4107.19 | 28-FEB-16:01 | 4107.19 | 0.01 |
March | 0.00 | 0.00 | 0.422228E+09 | 0.277823E+09 | 4333.50 | 28-MAR-15:02 | 3640.89 | 0.20 |
April | 0.00 | 0.00 | 0.101651E+10 | 0.615137E+09 | 4696.45 | 21-APR-18:02 | 3487.39 | 0.54 |
May | 0.00 | 0.00 | 0.191440E+10 | 0.108524E+10 | 4959.51 | 28-MAY-08:62 | 3145.77 | 0.81 |
June | 0.00 | 0.00 | 0.290886E+10 | 0.175270E+10 | 5459.38 | 29-JUN-08:62 | 3138.43 | 0.92 |
July | 0.00 | 0.00 | 0.342114E+10 | 0.205501E+10 | 5513.01 | 30-JUL-08:62 | 2893.53 | 0.93 |
August | 0.00 | 0.00 | 0.351241E+10 | 0.206710E+10 | 5398.23 | 12-AUG-08:62 | 3173.24 | 0.94 |
September | 0.00 | 0.00 | 0.192717E+10 | 0.997378E+09 | 5454.84 | 17-SEP-08:62 | 3038.18 | 0.83 |
October | 0.00 | 0.00 | 0.638050E+09 | 0.335269E+09 | 5055.16 | 18-OCT-15:02 | 3363.42 | 0.36 |
November | 0.00 | 0.00 | 0.120891E+09 | 65494273.12 | 4533.81 | 05-NOV-15:02 | 3644.62 | 0.09 |
December | 0.00 | 0.00 | 11230854.36 | 4415731.28 | 3701.85 | 11-DEC-16:02 | 3310.33 | 0.02 |
Annual Sum or Average | 0.00 | 0.00 | 0.159678E+11 | 0.932717E+10 | 0.47 | |||
Minimum of Months | 0.00 | 0.00 | 1294287.95 | 826905.34 | 1029.96 | 317.26 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.351241E+10 | 0.206710E+10 | 5513.01 | 4107.19 | 0.94 |
Report: CoilReportMonthly
For: ROOM_3_MULT9_FLR_6 FAN COIL COOLING COIL
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.968966E+09 | 0.879110E+09 | 19149.15 | 13-JAN-16:01 | 19149.15 | 0.03 |
February | 0.00 | 0.00 | 0.207855E+10 | 0.193331E+10 | 19171.21 | 28-FEB-16:01 | 19171.21 | 0.07 |
March | 0.00 | 0.00 | 0.507141E+10 | 0.373886E+10 | 20377.74 | 28-MAR-15:02 | 17430.55 | 0.33 |
April | 0.00 | 0.00 | 0.701954E+10 | 0.437275E+10 | 22261.22 | 21-APR-18:02 | 16048.05 | 0.65 |
May | 0.00 | 0.00 | 0.102714E+11 | 0.569242E+10 | 22656.29 | 27-MAY-08:62 | 14437.55 | 0.83 |
June | 0.00 | 0.00 | 0.141344E+11 | 0.837962E+10 | 26015.38 | 29-JUN-08:62 | 14314.29 | 0.91 |
July | 0.00 | 0.00 | 0.170350E+11 | 0.102382E+11 | 25790.42 | 30-JUL-08:62 | 14059.65 | 0.92 |
August | 0.00 | 0.00 | 0.189524E+11 | 0.119019E+11 | 25502.53 | 29-AUG-08:62 | 14471.77 | 0.94 |
September | 0.00 | 0.00 | 0.131787E+11 | 0.778169E+10 | 25430.90 | 17-SEP-08:62 | 14710.73 | 0.88 |
October | 0.00 | 0.00 | 0.808785E+10 | 0.514068E+10 | 22918.23 | 01-OCT-18:01 | 16069.02 | 0.65 |
November | 0.00 | 0.00 | 0.448536E+10 | 0.341044E+10 | 21702.13 | 27-NOV-19:03 | 15354.00 | 0.28 |
December | 0.00 | 0.00 | 0.213300E+10 | 0.175897E+10 | 21111.45 | 13-DEC-16:03 | 15670.96 | 0.09 |
Annual Sum or Average | 0.00 | 0.00 | 0.103416E+12 | 0.652280E+11 | 0.55 | |||
Minimum of Months | 0.00 | 0.00 | 0.968966E+09 | 0.879110E+09 | 19149.15 | 14059.65 | 0.03 | |
Maximum of Months | 0.00 | 0.00 | 0.189524E+11 | 0.119019E+11 | 26015.38 | 19171.21 | 0.94 |
Report: PlantLoopDemandReportMonthly
For: HEATSYS1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 66437.49 | 227651.54 | 07-JAN-16:06 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 53455.30 | 271426.31 | 12-FEB-07:10 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 27945.60 | 140801.43 | 23-MAR-08:62 |
April | 0.00 | 0.00 | 01-APR-00:10 | 24002.45 | 128622.50 | 06-APR-08:62 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 18402.18 | 79482.28 | 10-MAY-08:04 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 13407.03 | 78651.59 | 08-JUN-11:13 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 11651.93 | 67592.25 | 03-JUL-10:35 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 9430.70 | 66693.96 | 08-AUG-10:35 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 10892.52 | 87426.83 | 30-SEP-15:05 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 18318.45 | 138521.36 | 26-OCT-08:62 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 27339.44 | 151334.36 | 21-NOV-09:02 |
December | 0.00 | 0.00 | 01-DEC-00:05 | 43035.56 | 175527.61 | 18-DEC-09:02 |
Annual Sum or Average | 0.00 | 26898.28 | ||||
Minimum of Months | 0.00 | 0.00 | 9430.70 | 66693.96 | ||
Maximum of Months | 0.00 | 0.00 | 66437.49 | 271426.31 |
Report: PlantLoopDemandReportMonthly
For: COOLSYS1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 12142.32 | 301314.76 | 19-JAN-19:05 | 0.00 | 0.00 | 01-JAN-00:05 |
February | 39544.40 | 470834.53 | 28-FEB-16:01 | 0.00 | 0.00 | 01-FEB-00:03 |
March | 96856.67 | 569635.25 | 30-MAR-18:03 | 0.00 | 0.00 | 01-MAR-00:03 |
April | 185330.29 | 635662.03 | 30-APR-18:02 | 0.00 | 0.00 | 01-APR-00:10 |
May | 330266.65 | 773271.28 | 30-MAY-18:03 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 492128.37 | 869291.04 | 17-JUN-21:00 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 597359.33 | 907732.38 | 26-JUL-18:03 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 622909.85 | 911772.97 | 21-AUG-18:03 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 426358.81 | 884571.64 | 16-SEP-18:03 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 186728.77 | 826166.51 | 18-OCT-18:03 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 81600.20 | 656906.49 | 27-NOV-19:03 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 22935.78 | 420711.49 | 13-DEC-11:40 | 0.00 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 259219.05 | 0.00 | ||||
Minimum of Months | 12142.32 | 301314.76 | 0.00 | 0.00 | ||
Maximum of Months | 622909.85 | 911772.97 | 0.00 | 0.00 |
Report: PlantLoopDemandReportMonthly
For: SWHSYS1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 26247.15 | 53419.87 | 30-JAN-07:40 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 26301.43 | 53424.63 | 01-FEB-07:40 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 25491.07 | 52578.89 | 01-MAR-07:20 |
April | 0.00 | 0.00 | 01-APR-00:10 | 23947.66 | 49717.39 | 03-APR-06:40 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 22133.21 | 46386.54 | 01-MAY-06:25 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 20524.26 | 42494.95 | 01-JUN-06:10 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 19532.17 | 39633.80 | 03-JUL-06:10 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 19481.07 | 39492.35 | 31-AUG-06:10 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 20329.27 | 41905.71 | 29-SEP-06:20 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 21867.23 | 45785.72 | 31-OCT-06:10 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 23686.04 | 49455.11 | 30-NOV-07:50 |
December | 0.00 | 0.00 | 01-DEC-00:05 | 25284.44 | 52175.12 | 29-DEC-07:30 |
Annual Sum or Average | 0.00 | 22882.70 | ||||
Minimum of Months | 0.00 | 0.00 | 19481.07 | 39492.35 | ||
Maximum of Months | 0.00 | 0.00 | 26301.43 | 53424.63 |
Report: FanReportMonthly
For: FLR_3_DOAS FAN
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.587890E+10 | 0.91 | 2194.93 | 01-JAN-00:05 | 0.91 |
February | 0.530997E+10 | 0.91 | 2194.93 | 01-FEB-00:03 | 0.91 |
March | 0.587890E+10 | 0.91 | 2194.93 | 01-MAR-00:03 | 0.91 |
April | 0.568926E+10 | 0.90 | 2194.93 | 01-APR-00:10 | 0.91 |
May | 0.587890E+10 | 0.90 | 2194.93 | 01-MAY-00:10 | 0.90 |
June | 0.568926E+10 | 0.90 | 2194.93 | 01-JUN-00:10 | 0.90 |
July | 0.587890E+10 | 0.90 | 2194.93 | 01-JUL-00:10 | 0.90 |
August | 0.587890E+10 | 0.90 | 2194.93 | 01-AUG-00:10 | 0.90 |
September | 0.568926E+10 | 0.90 | 2194.93 | 01-SEP-00:10 | 0.90 |
October | 0.587890E+10 | 0.90 | 2194.93 | 01-OCT-00:10 | 0.90 |
November | 0.568926E+10 | 0.91 | 2194.93 | 01-NOV-00:10 | 0.91 |
December | 0.587890E+10 | 0.91 | 2194.93 | 01-DEC-00:05 | 0.91 |
Annual Sum or Average | 0.692193E+11 | 0.91 | |||
Minimum of Months | 0.530997E+10 | 0.90 | 2194.93 | 0.90 | |
Maximum of Months | 0.587890E+10 | 0.91 | 2194.93 | 0.91 |
Report: FanReportMonthly
For: VAV WITH REHEAT FAN
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.132468E+12 | 1.91 | 49457.77 | 01-JAN-00:05 | 1.90 |
February | 0.119648E+12 | 1.90 | 49457.77 | 01-FEB-00:03 | 1.90 |
March | 0.132467E+12 | 1.90 | 49457.77 | 01-MAR-00:03 | 1.90 |
April | 0.128194E+12 | 1.89 | 49457.77 | 01-APR-00:10 | 1.90 |
May | 0.132467E+12 | 1.89 | 49457.77 | 01-MAY-00:10 | 1.88 |
June | 0.128194E+12 | 1.89 | 49457.77 | 01-JUN-00:10 | 1.88 |
July | 0.132468E+12 | 1.89 | 49457.77 | 01-JUL-00:10 | 1.88 |
August | 0.132468E+12 | 1.89 | 49457.77 | 01-AUG-00:10 | 1.88 |
September | 0.128194E+12 | 1.89 | 49457.77 | 01-SEP-00:10 | 1.88 |
October | 0.132467E+12 | 1.89 | 49457.77 | 01-OCT-00:10 | 1.88 |
November | 0.128194E+12 | 1.90 | 49457.77 | 01-NOV-00:10 | 1.90 |
December | 0.132467E+12 | 1.90 | 49457.77 | 01-DEC-00:05 | 1.90 |
Annual Sum or Average | 0.155969E+13 | 1.89 | |||
Minimum of Months | 0.119648E+12 | 1.89 | 49457.77 | 1.88 | |
Maximum of Months | 0.132468E+12 | 1.91 | 49457.77 | 1.90 |
Report: FanReportMonthly
For: LAUNDRY_FLR_1 EXHAUST FAN
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.493775E+09 | 0.66 | 184.35 | 01-JAN-00:05 | 0.66 |
February | 0.445990E+09 | 0.66 | 184.35 | 01-FEB-00:03 | 0.66 |
March | 0.493775E+09 | 0.66 | 184.35 | 01-MAR-00:03 | 0.66 |
April | 0.477847E+09 | 0.66 | 184.35 | 01-APR-00:10 | 0.66 |
May | 0.493775E+09 | 0.66 | 184.35 | 01-MAY-00:10 | 0.66 |
June | 0.477847E+09 | 0.66 | 184.35 | 01-JUN-00:10 | 0.66 |
July | 0.493775E+09 | 0.66 | 184.35 | 01-JUL-00:10 | 0.66 |
August | 0.493775E+09 | 0.66 | 184.35 | 01-AUG-00:10 | 0.66 |
September | 0.477847E+09 | 0.66 | 184.35 | 01-SEP-00:10 | 0.66 |
October | 0.493775E+09 | 0.66 | 184.35 | 01-OCT-00:10 | 0.66 |
November | 0.477847E+09 | 0.66 | 184.35 | 01-NOV-00:10 | 0.66 |
December | 0.493775E+09 | 0.66 | 184.35 | 01-DEC-00:05 | 0.66 |
Annual Sum or Average | 0.581380E+10 | 0.66 | |||
Minimum of Months | 0.445990E+09 | 0.66 | 184.35 | 0.66 | |
Maximum of Months | 0.493775E+09 | 0.66 | 184.35 | 0.66 |
Report: FanReportMonthly
For: LOBBY_FLR_1 EXHAUST FAN
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 |
Report: FanReportMonthly
For: BANQUET_FLR_6 EXHAUST FAN
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 |
Report: FanReportMonthly
For: DINING_FLR_6 EXHAUST FAN
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 |
Report: FanReportMonthly
For: KITCHEN_FLR_6 EXHAUST FAN
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.279806E+10 | 0.47 | 1474.84 | 01-JAN-07:10 | 0.66 |
February | 0.252728E+10 | 0.47 | 1474.84 | 01-FEB-07:05 | 0.66 |
March | 0.279806E+10 | 0.47 | 1474.84 | 01-MAR-07:05 | 0.66 |
April | 0.270780E+10 | 0.47 | 1474.84 | 01-APR-06:10 | 0.66 |
May | 0.279806E+10 | 0.47 | 1474.84 | 01-MAY-06:05 | 0.66 |
June | 0.270780E+10 | 0.47 | 1474.84 | 01-JUN-06:05 | 0.66 |
July | 0.279806E+10 | 0.46 | 1474.84 | 01-JUL-06:10 | 0.66 |
August | 0.279806E+10 | 0.46 | 1474.84 | 01-AUG-06:05 | 0.66 |
September | 0.270780E+10 | 0.46 | 1474.84 | 01-SEP-06:05 | 0.66 |
October | 0.279806E+10 | 0.47 | 1474.84 | 01-OCT-06:10 | 0.66 |
November | 0.270780E+10 | 0.47 | 1474.84 | 01-NOV-06:05 | 0.66 |
December | 0.279806E+10 | 0.47 | 1474.84 | 01-DEC-07:10 | 0.66 |
Annual Sum or Average | 0.329449E+11 | 0.47 | |||
Minimum of Months | 0.252728E+10 | 0.46 | 1474.84 | 0.66 | |
Maximum of Months | 0.279806E+10 | 0.47 | 1474.84 | 0.66 |
Report: FanReportMonthly
For: ROOM_1_FLR_3 FAN COIL FAN COILFAN_FAN
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.781339E+09 | 1.11 | 1826.87 | 01-JAN-09:02 | 1.43 |
February | 0.576670E+09 | 1.11 | 1826.87 | 01-FEB-09:02 | 1.44 |
March | 0.453411E+09 | 1.09 | 1826.87 | 03-MAR-09:02 | 1.43 |
April | 0.556155E+09 | 1.15 | 1826.87 | 01-APR-15:02 | 1.43 |
May | 0.746419E+09 | 1.23 | 1826.87 | 01-MAY-15:02 | 1.42 |
June | 0.105258E+10 | 1.31 | 1826.87 | 01-JUN-08:62 | 1.42 |
July | 0.120887E+10 | 1.32 | 1826.87 | 01-JUL-08:61 | 1.42 |
August | 0.127223E+10 | 1.34 | 1826.87 | 01-AUG-08:62 | 1.42 |
September | 0.809414E+09 | 1.25 | 1826.87 | 01-SEP-08:62 | 1.42 |
October | 0.508491E+09 | 1.13 | 1826.87 | 01-OCT-15:01 | 1.42 |
November | 0.399419E+09 | 1.07 | 1826.87 | 01-NOV-08:62 | 1.43 |
December | 0.566758E+09 | 1.05 | 1826.87 | 01-DEC-09:02 | 1.44 |
Annual Sum or Average | 0.893175E+10 | 1.18 | |||
Minimum of Months | 0.399419E+09 | 1.05 | 1826.87 | 1.42 | |
Maximum of Months | 0.127223E+10 | 1.34 | 1826.87 | 1.44 |
Report: FanReportMonthly
For: ROOM_2_FLR_3 FAN COIL FAN COILFAN_FAN
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.937140E+09 | 1.22 | 1806.26 | 01-JAN-09:02 | 1.43 |
February | 0.662224E+09 | 1.15 | 1806.26 | 01-FEB-09:02 | 1.44 |
March | 0.407266E+09 | 1.04 | 1806.26 | 02-MAR-09:02 | 1.43 |
April | 0.488671E+09 | 1.10 | 1806.26 | 01-APR-15:02 | 1.43 |
May | 0.711128E+09 | 1.20 | 1806.26 | 01-MAY-15:02 | 1.42 |
June | 0.104592E+10 | 1.31 | 1806.26 | 01-JUN-08:62 | 1.42 |
July | 0.119386E+10 | 1.32 | 1806.26 | 01-JUL-08:61 | 1.42 |
August | 0.120654E+10 | 1.33 | 1806.26 | 01-AUG-08:62 | 1.42 |
September | 0.706619E+09 | 1.20 | 1806.26 | 01-SEP-08:62 | 1.42 |
October | 0.408739E+09 | 1.05 | 1806.26 | 01-OCT-15:01 | 1.42 |
November | 0.407168E+09 | 1.04 | 1806.26 | 01-NOV-08:62 | 1.43 |
December | 0.664189E+09 | 1.10 | 1806.26 | 01-DEC-09:02 | 1.44 |
Annual Sum or Average | 0.883946E+10 | 1.17 | |||
Minimum of Months | 0.407168E+09 | 1.04 | 1806.26 | 1.42 | |
Maximum of Months | 0.120654E+10 | 1.33 | 1806.26 | 1.44 |
Report: FanReportMonthly
For: ROOM_3_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.798667E+09 | 0.31 | 3012.13 | 08-JAN-05:10 | 1.44 |
February | 0.875905E+09 | 0.34 | 3155.60 | 26-FEB-14:50 | 1.44 |
March | 0.168546E+10 | 0.67 | 3047.41 | 11-MAR-12:30 | 1.43 |
April | 0.221470E+10 | 0.91 | 3189.09 | 15-APR-14:00 | 1.43 |
May | 0.279742E+10 | 1.07 | 2720.77 | 19-MAY-19:10 | 1.43 |
June | 0.401879E+10 | 1.34 | 3130.86 | 24-JUN-19:10 | 1.43 |
July | 0.467586E+10 | 1.38 | 3424.40 | 08-JUL-19:10 | 1.43 |
August | 0.540115E+10 | 1.43 | 3526.25 | 19-AUG-13:50 | 1.43 |
September | 0.390567E+10 | 1.23 | 5144.25 | 24-SEP-12:30 | 1.43 |
October | 0.281690E+10 | 0.89 | 5180.59 | 10-OCT-13:40 | 1.43 |
November | 0.166357E+10 | 0.66 | 3577.97 | 06-NOV-14:30 | 1.43 |
December | 0.734265E+09 | 0.31 | 3348.16 | 10-DEC-14:10 | 1.44 |
Annual Sum or Average | 0.315884E+11 | 0.88 | |||
Minimum of Months | 0.734265E+09 | 0.31 | 2720.77 | 1.43 | |
Maximum of Months | 0.540115E+10 | 1.43 | 5180.59 | 1.44 |
Report: FanReportMonthly
For: ROOM_4_MULT19_FLR_3 FAN COIL FAN COILFAN_FAN
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.363762E+10 | 1.02 | 11892.41 | 01-JAN-09:02 | 1.43 |
February | 0.294918E+10 | 1.02 | 11892.41 | 01-FEB-09:02 | 1.44 |
March | 0.291151E+10 | 1.02 | 11892.41 | 02-MAR-16:02 | 1.43 |
April | 0.432992E+10 | 1.01 | 11892.41 | 01-APR-08:62 | 1.43 |
May | 0.633653E+10 | 1.04 | 11892.41 | 01-MAY-15:02 | 1.43 |
June | 0.835447E+10 | 1.16 | 11892.41 | 01-JUN-08:62 | 1.42 |
July | 0.926747E+10 | 1.19 | 11892.41 | 01-JUL-08:61 | 1.42 |
August | 0.912410E+10 | 1.18 | 11892.41 | 01-AUG-08:62 | 1.42 |
September | 0.615675E+10 | 1.04 | 11892.41 | 01-SEP-08:62 | 1.42 |
October | 0.347770E+10 | 1.01 | 11892.41 | 01-OCT-08:63 | 1.42 |
November | 0.237719E+10 | 1.02 | 11892.41 | 02-NOV-15:02 | 1.43 |
December | 0.248409E+10 | 1.02 | 11892.41 | 01-DEC-09:02 | 1.44 |
Annual Sum or Average | 0.614065E+11 | 1.06 | |||
Minimum of Months | 0.237719E+10 | 1.01 | 11892.41 | 1.42 | |
Maximum of Months | 0.926747E+10 | 1.19 | 11892.41 | 1.44 |
Report: FanReportMonthly
For: ROOM_5_FLR_3 FAN COIL FAN COILFAN_FAN
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.749628E+09 | 1.10 | 1645.96 | 01-JAN-09:02 | 1.43 |
February | 0.557883E+09 | 1.12 | 1645.96 | 01-FEB-09:02 | 1.44 |
March | 0.398272E+09 | 1.10 | 1645.96 | 02-MAR-16:02 | 1.43 |
April | 0.518815E+09 | 1.18 | 1645.96 | 02-APR-15:01 | 1.42 |
May | 0.745232E+09 | 1.29 | 1645.96 | 01-MAY-15:02 | 1.42 |
June | 0.107240E+10 | 1.37 | 1645.96 | 01-JUN-08:62 | 1.42 |
July | 0.124130E+10 | 1.35 | 1645.96 | 01-JUL-08:61 | 1.42 |
August | 0.127385E+10 | 1.37 | 1645.96 | 01-AUG-08:62 | 1.42 |
September | 0.798006E+09 | 1.28 | 1645.96 | 01-SEP-08:62 | 1.42 |
October | 0.475508E+09 | 1.18 | 1645.96 | 01-OCT-15:01 | 1.42 |
November | 0.360670E+09 | 1.06 | 1645.96 | 01-NOV-08:62 | 1.43 |
December | 0.518729E+09 | 1.04 | 1645.96 | 01-DEC-09:02 | 1.44 |
Annual Sum or Average | 0.871030E+10 | 1.20 | |||
Minimum of Months | 0.360670E+09 | 1.04 | 1645.96 | 1.42 | |
Maximum of Months | 0.127385E+10 | 1.37 | 1645.96 | 1.44 |
Report: FanReportMonthly
For: ROOM_6_FLR_3 FAN COIL FAN COILFAN_FAN
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.930681E+09 | 1.21 | 1630.90 | 01-JAN-09:02 | 1.43 |
February | 0.624841E+09 | 1.14 | 1630.90 | 01-FEB-09:02 | 1.44 |
March | 0.346563E+09 | 1.02 | 1630.90 | 03-MAR-09:02 | 1.43 |
April | 0.447977E+09 | 1.14 | 1630.90 | 02-APR-15:01 | 1.42 |
May | 0.708939E+09 | 1.28 | 1630.90 | 01-MAY-15:02 | 1.42 |
June | 0.106778E+10 | 1.37 | 1630.90 | 01-JUN-08:62 | 1.42 |
July | 0.122774E+10 | 1.35 | 1630.90 | 01-JUL-08:61 | 1.42 |
August | 0.121134E+10 | 1.36 | 1630.90 | 01-AUG-08:62 | 1.42 |
September | 0.690993E+09 | 1.27 | 1630.90 | 01-SEP-08:62 | 1.42 |
October | 0.378393E+09 | 1.06 | 1630.90 | 01-OCT-15:01 | 1.42 |
November | 0.361077E+09 | 1.02 | 1630.90 | 01-NOV-08:62 | 1.43 |
December | 0.621203E+09 | 1.09 | 1630.90 | 01-DEC-09:02 | 1.44 |
Annual Sum or Average | 0.861752E+10 | 1.19 | |||
Minimum of Months | 0.346563E+09 | 1.02 | 1630.90 | 1.42 | |
Maximum of Months | 0.122774E+10 | 1.37 | 1630.90 | 1.44 |
Report: FanReportMonthly
For: ROOM_1_FLR_6 FAN COIL FAN COILFAN_FAN
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.263961E+09 | 1.17 | 490.18 | 01-JAN-09:02 | 1.43 |
February | 0.190954E+09 | 1.16 | 490.18 | 01-FEB-09:02 | 1.44 |
March | 0.133520E+09 | 1.11 | 490.18 | 02-MAR-09:02 | 1.43 |
April | 0.160949E+09 | 1.18 | 490.18 | 01-APR-15:02 | 1.43 |
May | 0.217305E+09 | 1.27 | 490.18 | 01-MAY-15:02 | 1.42 |
June | 0.303312E+09 | 1.33 | 490.18 | 01-JUN-08:62 | 1.42 |
July | 0.349083E+09 | 1.33 | 490.18 | 01-JUL-08:61 | 1.42 |
August | 0.364777E+09 | 1.35 | 490.18 | 01-AUG-08:62 | 1.42 |
September | 0.226646E+09 | 1.27 | 490.18 | 01-SEP-15:02 | 1.43 |
October | 0.147118E+09 | 1.16 | 490.18 | 01-OCT-15:01 | 1.42 |
November | 0.122585E+09 | 1.08 | 490.18 | 01-NOV-08:62 | 1.43 |
December | 0.182897E+09 | 1.09 | 490.18 | 01-DEC-09:02 | 1.44 |
Annual Sum or Average | 0.266311E+10 | 1.21 | |||
Minimum of Months | 0.122585E+09 | 1.08 | 490.18 | 1.42 | |
Maximum of Months | 0.364777E+09 | 1.35 | 490.18 | 1.44 |
Report: FanReportMonthly
For: ROOM_2_FLR_6 FAN COIL FAN COILFAN_FAN
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.321232E+09 | 1.29 | 484.08 | 01-JAN-09:02 | 1.43 |
February | 0.213790E+09 | 1.20 | 484.08 | 01-FEB-09:02 | 1.44 |
March | 0.121532E+09 | 1.06 | 484.08 | 02-MAR-09:02 | 1.43 |
April | 0.142927E+09 | 1.14 | 484.08 | 02-APR-15:01 | 1.42 |
May | 0.207867E+09 | 1.26 | 484.08 | 01-MAY-15:02 | 1.42 |
June | 0.302231E+09 | 1.33 | 484.08 | 01-JUN-08:62 | 1.42 |
July | 0.345782E+09 | 1.33 | 484.08 | 01-JUL-08:61 | 1.42 |
August | 0.346725E+09 | 1.34 | 484.08 | 01-AUG-08:62 | 1.42 |
September | 0.199082E+09 | 1.24 | 484.08 | 01-SEP-15:02 | 1.42 |
October | 0.122301E+09 | 1.08 | 484.08 | 01-OCT-15:01 | 1.42 |
November | 0.130201E+09 | 1.06 | 484.08 | 01-NOV-08:62 | 1.43 |
December | 0.217768E+09 | 1.17 | 484.08 | 01-DEC-09:02 | 1.44 |
Annual Sum or Average | 0.267144E+10 | 1.21 | |||
Minimum of Months | 0.121532E+09 | 1.06 | 484.08 | 1.42 | |
Maximum of Months | 0.346725E+09 | 1.34 | 484.08 | 1.44 |
Report: FanReportMonthly
For: ROOM_3_MULT9_FLR_6 FAN COIL FAN COILFAN_FAN
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.872852E+09 | 1.12 | 2245.86 | 01-JAN-16:02 | 1.43 |
February | 0.716513E+09 | 1.13 | 2245.86 | 01-FEB-09:02 | 1.44 |
March | 0.732913E+09 | 1.17 | 2245.86 | 02-MAR-16:02 | 1.43 |
April | 0.847520E+09 | 1.20 | 2245.86 | 01-APR-15:02 | 1.43 |
May | 0.107584E+10 | 1.26 | 2245.86 | 01-MAY-15:02 | 1.42 |
June | 0.143571E+10 | 1.31 | 2245.86 | 01-JUN-08:62 | 1.42 |
July | 0.166842E+10 | 1.32 | 2245.86 | 01-JUL-08:61 | 1.42 |
August | 0.184702E+10 | 1.34 | 2245.86 | 01-AUG-08:62 | 1.42 |
September | 0.132276E+10 | 1.27 | 2245.86 | 01-SEP-08:62 | 1.42 |
October | 0.969115E+09 | 1.23 | 2245.86 | 01-OCT-15:01 | 1.42 |
November | 0.689232E+09 | 1.16 | 2245.86 | 01-NOV-15:02 | 1.43 |
December | 0.703563E+09 | 1.13 | 2245.86 | 01-DEC-09:02 | 1.44 |
Annual Sum or Average | 0.128815E+11 | 1.22 | |||
Minimum of Months | 0.689232E+09 | 1.12 | 2245.86 | 1.42 | |
Maximum of Months | 0.184702E+10 | 1.34 | 2245.86 | 1.44 |
Report: PumpReportMonthly
For: HEATSYS1 PUMP
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPUMP ELECTRICITY ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRICITY RATE {Maximum} [W] | PUMP ELECTRICITY RATE {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
January | 0.140579E+10 | 0.126521E+10 | 1018.48 | 07-JAN-17:00 | 916.63 | 916.63 | 37.36 | 2.30 |
February | 0.100584E+10 | 0.905257E+09 | 1061.79 | 12-FEB-07:10 | 955.61 | 955.61 | 36.50 | 2.76 |
March | 0.635184E+09 | 0.571665E+09 | 802.45 | 23-MAR-08:62 | 722.21 | 722.21 | 33.36 | 1.26 |
April | 0.529654E+09 | 0.476689E+09 | 770.96 | 06-APR-08:62 | 693.86 | 693.86 | 33.87 | 1.18 |
May | 0.409913E+09 | 0.368921E+09 | 574.03 | 13-MAY-12:02 | 516.63 | 516.63 | 35.81 | 0.75 |
June | 0.285582E+09 | 0.257024E+09 | 638.13 | 08-JUN-11:13 | 574.32 | 574.32 | 38.48 | 0.87 |
July | 0.252652E+09 | 0.227386E+09 | 471.57 | 03-JUL-10:40 | 424.41 | 424.41 | 33.97 | 0.58 |
August | 0.201586E+09 | 0.181428E+09 | 447.20 | 01-AUG-10:35 | 402.48 | 402.48 | 32.24 | 0.55 |
September | 0.213526E+09 | 0.192174E+09 | 547.50 | 30-SEP-15:05 | 492.75 | 492.75 | 30.51 | 0.71 |
October | 0.401873E+09 | 0.361686E+09 | 772.36 | 26-OCT-08:62 | 695.12 | 695.12 | 31.97 | 1.18 |
November | 0.610974E+09 | 0.549876E+09 | 810.25 | 22-NOV-07:10 | 729.22 | 729.22 | 38.42 | 1.28 |
December | 0.100988E+10 | 0.908889E+09 | 896.20 | 18-DEC-07:40 | 806.58 | 806.58 | 36.79 | 1.58 |
Annual Sum or Average | 0.696245E+10 | 0.626620E+10 | ||||||
Minimum of Months | 0.201586E+09 | 0.181428E+09 | 447.20 | 402.48 | 402.48 | 30.51 | 0.55 | |
Maximum of Months | 0.140579E+10 | 0.126521E+10 | 1061.79 | 955.61 | 955.61 | 38.48 | 2.76 |
Report: PumpReportMonthly
For: COOLSYS1 PUMP SECONDARY
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPUMP ELECTRICITY ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRICITY RATE {Maximum} [W] | PUMP ELECTRICITY RATE {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
January | 0.752485E+09 | 0.677236E+09 | 5578.14 | 31-JAN-16:02 | 5020.32 | 5020.32 | 6.73 | 12.33 |
February | 0.209322E+10 | 0.188390E+10 | 5998.52 | 26-FEB-16:02 | 5398.67 | 5398.67 | 6.73 | 14.01 |
March | 0.546802E+10 | 0.492122E+10 | 7380.37 | 11-MAR-19:01 | 6642.33 | 6642.33 | 6.73 | 23.16 |
April | 0.910480E+10 | 0.819432E+10 | 7418.79 | 15-APR-15:13 | 6676.91 | 6676.91 | 6.73 | 23.60 |
May | 0.136764E+11 | 0.123087E+11 | 7621.86 | 30-MAY-18:03 | 6859.67 | 6859.67 | 6.73 | 26.29 |
June | 0.164138E+11 | 0.147724E+11 | 7911.48 | 28-JUN-18:03 | 7120.34 | 7120.34 | 6.73 | 31.06 |
July | 0.186645E+11 | 0.167981E+11 | 8041.55 | 06-JUL-18:03 | 7237.40 | 7237.40 | 6.73 | 33.17 |
August | 0.189855E+11 | 0.170869E+11 | 8030.44 | 10-AUG-18:03 | 7227.40 | 7227.40 | 6.73 | 33.00 |
September | 0.150576E+11 | 0.135519E+11 | 7861.54 | 06-SEP-18:03 | 7075.38 | 7075.38 | 6.73 | 30.21 |
October | 0.849974E+10 | 0.764976E+10 | 7708.09 | 18-OCT-18:03 | 6937.28 | 6937.28 | 6.73 | 27.62 |
November | 0.429030E+10 | 0.386127E+10 | 7182.12 | 27-NOV-19:03 | 6463.91 | 6463.91 | 6.73 | 21.18 |
December | 0.145512E+10 | 0.130961E+10 | 5962.39 | 12-DEC-16:02 | 5366.15 | 5366.15 | 6.73 | 13.86 |
Annual Sum or Average | 0.114461E+12 | 0.103015E+12 | ||||||
Minimum of Months | 0.752485E+09 | 0.677236E+09 | 5578.14 | 5020.32 | 5020.32 | 6.73 | 12.33 | |
Maximum of Months | 0.189855E+11 | 0.170869E+11 | 8041.55 | 7237.40 | 7237.40 | 6.73 | 33.17 |
Report: PumpReportMonthly
For: COOLSYS1 PUMP
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPUMP ELECTRICITY ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRICITY RATE {Maximum} [W] | PUMP ELECTRICITY RATE {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
January | 0.504843E+10 | 0.454358E+10 | 6835.92 | 01-JAN-00:05 | 6152.33 | 6152.33 | 6.73 | 47.91 |
February | 0.810262E+10 | 0.729236E+10 | 6835.92 | 01-FEB-00:03 | 6152.33 | 6152.33 | 6.77 | 47.91 |
March | 0.153795E+11 | 0.138415E+11 | 6835.92 | 01-MAR-00:03 | 6152.33 | 6152.33 | 7.10 | 47.91 |
April | 0.168758E+11 | 0.151883E+11 | 6835.92 | 01-APR-00:10 | 6152.33 | 6152.33 | 6.80 | 47.91 |
May | 0.182519E+11 | 0.164267E+11 | 6835.92 | 01-MAY-00:10 | 6152.33 | 6152.33 | 8.08 | 47.91 |
June | 0.177187E+11 | 0.159468E+11 | 6835.92 | 01-JUN-00:10 | 6152.33 | 6152.33 | 9.11 | 47.91 |
July | 0.183093E+11 | 0.164784E+11 | 6835.92 | 01-JUL-00:10 | 6152.33 | 6152.33 | 9.35 | 47.91 |
August | 0.183093E+11 | 0.164784E+11 | 6835.92 | 01-AUG-00:10 | 6152.33 | 6152.33 | 9.44 | 47.91 |
September | 0.177105E+11 | 0.159395E+11 | 6835.92 | 01-SEP-00:10 | 6152.33 | 6152.33 | 9.01 | 47.91 |
October | 0.170338E+11 | 0.153305E+11 | 6835.92 | 01-OCT-00:10 | 6152.33 | 6152.33 | 7.70 | 47.91 |
November | 0.133102E+11 | 0.119792E+11 | 6835.92 | 01-NOV-00:10 | 6152.33 | 6152.33 | 6.74 | 47.91 |
December | 0.832947E+10 | 0.749653E+10 | 6835.92 | 01-DEC-09:05 | 6152.33 | 6152.33 | 6.78 | 47.91 |
Annual Sum or Average | 0.174380E+12 | 0.156942E+12 | ||||||
Minimum of Months | 0.504843E+10 | 0.454358E+10 | 6835.92 | 6152.33 | 6152.33 | 6.73 | 47.91 | |
Maximum of Months | 0.183093E+11 | 0.164784E+11 | 6835.92 | 6152.33 | 6152.33 | 9.44 | 47.91 |
Report: PumpReportMonthly
For: SWHSYS1 PUMP
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPUMP ELECTRICITY ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRICITY RATE {Maximum} [W] | PUMP ELECTRICITY RATE {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
January | 0.128314E+09 | 38494137.67 | 47.91 | 01-JAN-00:05 | 14.37 | 14.37 | 49.01 | 0.37 |
February | 0.115896E+09 | 34768898.54 | 47.91 | 01-FEB-00:03 | 14.37 | 14.37 | 49.27 | 0.37 |
March | 0.128314E+09 | 38494137.67 | 47.91 | 01-MAR-00:03 | 14.37 | 14.37 | 48.95 | 0.37 |
April | 0.124175E+09 | 37252391.29 | 47.91 | 01-APR-00:10 | 14.37 | 14.37 | 52.24 | 0.37 |
May | 0.128314E+09 | 38494137.67 | 47.91 | 01-MAY-00:10 | 14.37 | 14.37 | 53.24 | 0.37 |
June | 0.124175E+09 | 37252391.29 | 47.91 | 01-JUN-00:10 | 14.37 | 14.37 | 53.48 | 0.37 |
July | 0.128314E+09 | 38494137.67 | 47.91 | 01-JUL-00:10 | 14.37 | 14.37 | 53.63 | 0.37 |
August | 0.128314E+09 | 38494137.67 | 47.91 | 01-AUG-00:10 | 14.37 | 14.37 | 54.00 | 0.37 |
September | 0.124175E+09 | 37252391.29 | 47.91 | 01-SEP-00:10 | 14.37 | 14.37 | 53.73 | 0.37 |
October | 0.128314E+09 | 38494137.67 | 47.91 | 01-OCT-00:10 | 14.37 | 14.37 | 53.12 | 0.37 |
November | 0.124175E+09 | 37252391.29 | 47.91 | 01-NOV-00:10 | 14.37 | 14.37 | 52.72 | 0.37 |
December | 0.128314E+09 | 38494137.67 | 47.91 | 01-DEC-00:05 | 14.37 | 14.37 | 50.43 | 0.37 |
Annual Sum or Average | 0.151079E+10 | 0.453237E+09 | ||||||
Minimum of Months | 0.115896E+09 | 34768898.54 | 47.91 | 14.37 | 14.37 | 48.95 | 0.37 | |
Maximum of Months | 0.128314E+09 | 38494137.67 | 47.91 | 14.37 | 14.37 | 54.00 | 0.37 |
Report: CondLoopDemandReportMonthly
For: HEATSYS1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 40.11 | 60.00 | 66437.49 | 227651.54 | 07-JAN-16:06 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 38.66 | 60.00 | 53455.30 | 271426.31 | 12-FEB-07:10 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 25.78 | 60.00 | 27945.60 | 140801.43 | 23-MAR-08:62 |
April | 0.00 | 0.00 | 01-APR-00:10 | 30.62 | 60.00 | 24002.45 | 128622.50 | 06-APR-08:62 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 32.79 | 60.00 | 18402.18 | 79482.28 | 10-MAY-08:04 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 29.97 | 60.00 | 13407.03 | 78651.59 | 08-JUN-11:13 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 29.16 | 60.00 | 11651.93 | 67592.25 | 03-JUL-10:35 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.25 | 60.00 | 9430.70 | 66693.96 | 08-AUG-10:35 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 27.40 | 60.00 | 10892.52 | 87426.83 | 30-SEP-15:05 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 25.56 | 60.00 | 18318.45 | 138521.36 | 26-OCT-08:62 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 39.02 | 60.00 | 27339.44 | 151334.36 | 21-NOV-09:02 |
December | 0.00 | 0.00 | 01-DEC-00:05 | 42.16 | 60.00 | 43035.56 | 175527.61 | 18-DEC-09:02 |
Annual Sum or Average | 0.00 | 26898.28 | ||||||
Minimum of Months | 0.00 | 0.00 | 25.56 | 60.00 | 9430.70 | 66693.96 | ||
Maximum of Months | 0.00 | 0.00 | 42.16 | 60.00 | 66437.49 | 271426.31 |
Report: CondLoopDemandReportMonthly
For: COOLSYS1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 12142.32 | 301314.76 | 19-JAN-19:05 | 8.20 | 6.70 | 0.00 | 0.00 | 01-JAN-00:05 |
February | 39544.40 | 470834.53 | 28-FEB-16:01 | 9.04 | 6.70 | 0.00 | 0.00 | 01-FEB-00:03 |
March | 96856.67 | 569635.25 | 30-MAR-18:03 | 9.54 | 6.70 | 0.00 | 0.00 | 01-MAR-00:03 |
April | 185330.29 | 635662.03 | 30-APR-18:02 | 9.87 | 6.70 | 0.00 | 0.00 | 01-APR-00:10 |
May | 330266.65 | 773271.28 | 30-MAY-18:03 | 10.55 | 6.70 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 492128.37 | 869291.04 | 17-JUN-21:00 | 11.03 | 6.70 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 597359.33 | 907732.38 | 26-JUL-18:03 | 11.22 | 6.70 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 622909.85 | 911772.97 | 21-AUG-18:03 | 11.24 | 6.70 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 426358.81 | 884571.64 | 16-SEP-18:03 | 11.11 | 6.70 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 186728.77 | 826166.51 | 18-OCT-18:03 | 10.82 | 6.70 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 81600.20 | 656906.49 | 27-NOV-19:03 | 9.97 | 6.70 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 22935.78 | 420711.49 | 13-DEC-11:40 | 8.79 | 6.70 | 0.00 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 259219.05 | 0.00 | ||||||
Minimum of Months | 12142.32 | 301314.76 | 8.20 | 6.70 | 0.00 | 0.00 | ||
Maximum of Months | 622909.85 | 911772.97 | 11.24 | 6.70 | 0.00 | 0.00 |
Report: CondLoopDemandReportMonthly
For: SWHSYS1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 49.01 | 59.72 | 26247.15 | 53419.87 | 30-JAN-07:40 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 49.27 | 59.75 | 26301.43 | 53424.63 | 01-FEB-07:40 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 48.95 | 58.24 | 25491.07 | 52578.89 | 01-MAR-07:20 |
April | 0.00 | 0.00 | 01-APR-00:10 | 52.24 | 58.65 | 23947.66 | 49717.39 | 03-APR-06:40 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 53.24 | 59.61 | 22133.21 | 46386.54 | 01-MAY-06:25 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 53.48 | 59.18 | 20524.26 | 42494.95 | 01-JUN-06:10 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 53.63 | 58.67 | 19532.17 | 39633.80 | 03-JUL-06:10 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 54.00 | 58.94 | 19481.07 | 39492.35 | 31-AUG-06:10 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 53.73 | 58.76 | 20329.27 | 41905.71 | 29-SEP-06:20 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 53.12 | 59.53 | 21867.23 | 45785.72 | 31-OCT-06:10 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 52.72 | 58.58 | 23686.04 | 49455.11 | 30-NOV-07:50 |
December | 0.00 | 0.00 | 01-DEC-00:05 | 50.43 | 59.75 | 25284.44 | 52175.12 | 29-DEC-07:30 |
Annual Sum or Average | 0.00 | 22882.70 | ||||||
Minimum of Months | 0.00 | 0.00 | 48.95 | 58.24 | 19481.07 | 39492.35 | ||
Maximum of Months | 0.00 | 0.00 | 54.00 | 59.75 | 26301.43 | 53424.63 |
Report: ZoneTemperatureOscillationReportMonthly
For: BASEMENT
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: RETAIL_1_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: RETAIL_2_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: MECH_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: STORAGE_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: LAUNDRY_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CAFE_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: LOBBY_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_1_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_2_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_5_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_6_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORRIDOR_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_1_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_2_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: BANQUET_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: DINING_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: KITCHEN_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORRIDOR_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: VAV WITH REHEAT
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.129205E+12 | 0.00 | 0.206885E+11 | 0.132468E+12 | 0.00 | 0.00 |
February | 0.101865E+12 | 0.00 | 0.619588E+11 | 0.119648E+12 | 0.00 | 0.00 |
March | 0.702198E+11 | 0.00 | 0.172776E+12 | 0.132467E+12 | 0.00 | 0.00 |
April | 0.610046E+11 | 0.00 | 0.337422E+12 | 0.128194E+12 | 0.00 | 0.00 |
May | 0.495826E+11 | 0.00 | 0.654340E+12 | 0.132467E+12 | 0.00 | 0.00 |
June | 0.350134E+11 | 0.00 | 0.958015E+12 | 0.128194E+12 | 0.00 | 0.00 |
July | 0.314431E+11 | 0.00 | 0.122052E+13 | 0.132468E+12 | 0.00 | 0.00 |
August | 0.254467E+11 | 0.00 | 0.127288E+13 | 0.132468E+12 | 0.00 | 0.00 |
September | 0.283219E+11 | 0.00 | 0.831474E+12 | 0.128194E+12 | 0.00 | 0.00 |
October | 0.463614E+11 | 0.00 | 0.358318E+12 | 0.132467E+12 | 0.00 | 0.00 |
November | 0.613872E+11 | 0.00 | 0.142871E+12 | 0.128194E+12 | 0.00 | 0.00 |
December | 0.901819E+11 | 0.00 | 0.351406E+11 | 0.132467E+12 | 0.00 | 0.00 |
Annual Sum or Average | 0.730033E+12 | 0.00 | 0.606640E+13 | 0.155969E+13 | 0.00 | 0.00 |
Minimum of Months | 0.254467E+11 | 0.00 | 0.206885E+11 | 0.119648E+12 | 0.00 | 0.00 |
Maximum of Months | 0.129205E+12 | 0.00 | 0.127288E+13 | 0.132468E+12 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: FLR_3_DOAS
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.236652E+10 | 0.00 | 0.176252E+10 | 0.587890E+10 | 0.00 | 0.00 |
February | 0.151622E+10 | 0.00 | 0.553442E+10 | 0.530997E+10 | 0.00 | 0.00 |
March | 9828.15 | 0.00 | 0.173955E+11 | 0.587890E+10 | 0.00 | 0.00 |
April | 16300.08 | 0.00 | 0.355080E+11 | 0.568926E+10 | 0.00 | 0.00 |
May | 16049.72 | 0.00 | 0.702642E+11 | 0.587890E+10 | 0.00 | 0.00 |
June | 12994.82 | 0.00 | 0.102458E+12 | 0.568926E+10 | 0.00 | 0.00 |
July | 10403.82 | 0.00 | 0.129170E+12 | 0.587890E+10 | 0.00 | 0.00 |
August | 9160.79 | 0.00 | 0.131783E+12 | 0.587890E+10 | 0.00 | 0.00 |
September | 15856.84 | 0.00 | 0.921407E+11 | 0.568926E+10 | 0.00 | 0.00 |
October | 8592.93 | 0.00 | 0.382673E+11 | 0.587890E+10 | 0.00 | 0.00 |
November | 85031500.69 | 0.00 | 0.148105E+11 | 0.568926E+10 | 0.00 | 0.00 |
December | 0.300946E+09 | 0.00 | 0.325640E+10 | 0.587890E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.426882E+10 | 0.00 | 0.642351E+12 | 0.692193E+11 | 0.00 | 0.00 |
Minimum of Months | 8592.93 | 0.00 | 0.176252E+10 | 0.530997E+10 | 0.00 | 0.00 |
Maximum of Months | 0.236652E+10 | 0.00 | 0.131783E+12 | 0.587890E+10 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: VAV WITH REHEAT
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.132468E+12 | 0.206885E+11 | 0.129205E+12 | 0.750537E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.119648E+12 | 0.619588E+11 | 0.101865E+12 | 0.451079E+12 | 0.152125E+10 | 0.00 | 0.00 | 0.00 |
March | 0.132467E+12 | 0.172776E+12 | 0.702198E+11 | 0.178206E+12 | 0.936896E+10 | 0.00 | 0.00 | 0.00 |
April | 0.128194E+12 | 0.337422E+12 | 0.610046E+11 | 0.755700E+11 | 0.413638E+11 | 0.00 | 0.00 | 0.00 |
May | 0.132467E+12 | 0.654340E+12 | 0.495826E+11 | 0.105117E+11 | 0.131683E+12 | 0.00 | 0.00 | 0.00 |
June | 0.128194E+12 | 0.958015E+12 | 0.350134E+11 | 0.181786E+10 | 0.407345E+12 | 0.00 | 0.00 | 0.00 |
July | 0.132468E+12 | 0.122052E+13 | 0.314431E+11 | 0.00 | 0.630396E+12 | 0.00 | 0.00 | 0.00 |
August | 0.132468E+12 | 0.127288E+13 | 0.254467E+11 | 0.00 | 0.770246E+12 | 0.00 | 0.00 | 0.00 |
September | 0.128194E+12 | 0.831474E+12 | 0.283219E+11 | 0.151769E+10 | 0.312557E+12 | 0.00 | 0.00 | 0.00 |
October | 0.132467E+12 | 0.358318E+12 | 0.463614E+11 | 0.100487E+12 | 0.669817E+11 | 0.00 | 0.00 | 0.00 |
November | 0.128194E+12 | 0.142871E+12 | 0.613872E+11 | 0.257673E+12 | 0.601105E+10 | 0.00 | 0.00 | 0.00 |
December | 0.132467E+12 | 0.351406E+11 | 0.901819E+11 | 0.497326E+12 | 0.128073E+09 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.155969E+13 | 0.606640E+13 | 0.730033E+12 | 0.232472E+13 | 0.237760E+13 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.119648E+12 | 0.206885E+11 | 0.254467E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.132468E+12 | 0.127288E+13 | 0.129205E+12 | 0.750537E+12 | 0.770246E+12 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: FLR_3_DOAS
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.587890E+10 | 0.176252E+10 | 0.236652E+10 | 0.755328E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.530997E+10 | 0.553442E+10 | 0.151622E+10 | 0.470270E+11 | 53080480.23 | 0.00 | 0.00 | 0.00 |
March | 0.587890E+10 | 0.173955E+11 | 9828.15 | 0.205068E+11 | 0.111204E+10 | 0.00 | 0.00 | 0.00 |
April | 0.568926E+10 | 0.355080E+11 | 16300.08 | 0.904223E+10 | 0.290308E+10 | 0.00 | 0.00 | 0.00 |
May | 0.587890E+10 | 0.702642E+11 | 16049.72 | 0.152904E+10 | 0.126864E+11 | 0.00 | 0.00 | 0.00 |
June | 0.568926E+10 | 0.102458E+12 | 12994.82 | 0.378000E+09 | 0.413419E+11 | 0.00 | 0.00 | 0.00 |
July | 0.587890E+10 | 0.129170E+12 | 10403.82 | 0.00 | 0.628514E+11 | 0.00 | 0.00 | 0.00 |
August | 0.587890E+10 | 0.131783E+12 | 9160.79 | 0.00 | 0.795370E+11 | 0.00 | 0.00 | 0.00 |
September | 0.568926E+10 | 0.921407E+11 | 15856.84 | 0.303413E+09 | 0.305617E+11 | 0.00 | 0.00 | 0.00 |
October | 0.587890E+10 | 0.382673E+11 | 8592.93 | 0.123786E+11 | 0.603516E+10 | 0.00 | 0.00 | 0.00 |
November | 0.568926E+10 | 0.148105E+11 | 85031500.69 | 0.282877E+11 | 0.302126E+09 | 0.00 | 0.00 | 0.00 |
December | 0.587890E+10 | 0.325640E+10 | 0.300946E+09 | 0.528171E+11 | 16253743.87 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.692193E+11 | 0.642351E+12 | 0.426882E+10 | 0.247803E+12 | 0.237400E+12 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.530997E+10 | 0.176252E+10 | 8592.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.587890E+10 | 0.131783E+12 | 0.236652E+10 | 0.755328E+11 | 0.795370E+11 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: VAV WITH REHEAT
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.132468E+12 | 0.129205E+12 | 0.206885E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.119648E+12 | 0.101865E+12 | 0.619588E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.132467E+12 | 0.702198E+11 | 0.172776E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.128194E+12 | 0.610046E+11 | 0.337422E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.132467E+12 | 0.495826E+11 | 0.654340E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.128194E+12 | 0.350134E+11 | 0.958015E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.132468E+12 | 0.314431E+11 | 0.122052E+13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.132468E+12 | 0.254467E+11 | 0.127288E+13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.128194E+12 | 0.283219E+11 | 0.831474E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.132467E+12 | 0.463614E+11 | 0.358318E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.128194E+12 | 0.613872E+11 | 0.142871E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.132467E+12 | 0.901819E+11 | 0.351406E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.155969E+13 | 0.730033E+12 | 0.606640E+13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.119648E+12 | 0.254467E+11 | 0.206885E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.132468E+12 | 0.129205E+12 | 0.127288E+13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: FLR_3_DOAS
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.587890E+10 | 0.236652E+10 | 0.176252E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.530997E+10 | 0.151622E+10 | 0.553442E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.587890E+10 | 9828.15 | 0.173955E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.568926E+10 | 16300.08 | 0.355080E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.587890E+10 | 16049.72 | 0.702642E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.568926E+10 | 12994.82 | 0.102458E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.587890E+10 | 10403.82 | 0.129170E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.587890E+10 | 9160.79 | 0.131783E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.568926E+10 | 15856.84 | 0.921407E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.587890E+10 | 8592.93 | 0.382673E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.568926E+10 | 85031500.69 | 0.148105E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.587890E+10 | 0.300946E+09 | 0.325640E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.692193E+11 | 0.426882E+10 | 0.642351E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.530997E+10 | 8592.93 | 0.176252E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.587890E+10 | 0.236652E+10 | 0.131783E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: BASEMENT
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.679748E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.86 |
February | 0.572383E+11 | 0.00 | 0.00 | 0.00 | 61881530.75 | 0.00 | 0.00 | 0.00 | 1.87 |
March | 0.520038E+11 | 0.00 | 4269329.36 | 0.00 | 0.631144E+09 | 53264294.73 | 0.00 | 38157.95 | 1.87 |
April | 0.348664E+11 | 0.00 | 0.124283E+10 | 0.00 | 0.245653E+10 | 0.625266E+09 | 0.00 | 8218066.41 | 1.88 |
May | 0.147631E+11 | 0.00 | 0.677209E+09 | 0.00 | 0.136153E+11 | 1205850.66 | 0.00 | 2642113.85 | 1.88 |
June | 0.561968E+10 | 0.00 | 18632855.53 | 0.00 | 0.391534E+11 | 0.00 | 0.00 | 79677.62 | 1.89 |
July | 93620853.32 | 0.00 | 0.00 | 0.00 | 0.594036E+11 | 0.00 | 0.00 | 0.00 | 1.88 |
August | 2297061.96 | 0.00 | 0.00 | 0.00 | 0.645739E+11 | 0.00 | 0.00 | 0.00 | 1.89 |
September | 0.915508E+10 | 0.00 | 0.00 | 0.00 | 0.300007E+11 | 0.00 | 0.00 | 0.00 | 1.89 |
October | 0.410622E+11 | 0.00 | 0.00 | 0.00 | 0.913128E+10 | 0.00 | 0.00 | 0.00 | 1.88 |
November | 0.534570E+11 | 0.00 | 0.00 | 0.00 | 0.114787E+10 | 0.00 | 0.00 | 0.00 | 1.88 |
December | 0.657473E+11 | 0.00 | 0.00 | 0.00 | 0.146548E+09 | 0.00 | 0.00 | 0.00 | 1.87 |
Annual Sum or Average | 0.401983E+12 | 0.00 | 0.194294E+10 | 0.00 | 0.220322E+12 | 0.679736E+09 | 0.00 | 10978015.82 | 1.88 |
Minimum of Months | 2297061.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.86 |
Maximum of Months | 0.679748E+11 | 0.00 | 0.124283E+10 | 0.00 | 0.645739E+11 | 0.625266E+09 | 0.00 | 8218066.41 | 1.89 |
Report: MechanicalVentilationLoadsMonthly
For: RETAIL_1_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.433692E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.482384E+10 | 0.00 | 0.00 | 4.55 |
February | 0.479746E+10 | 335250.69 | 0.00 | 0.00 | 8004336.57 | 0.291637E+10 | 0.00 | 0.00 | 4.57 |
March | 0.640977E+10 | 0.00 | 0.00 | 0.00 | 85637864.38 | 0.605804E+09 | 0.00 | 0.00 | 4.58 |
April | 0.445490E+10 | 0.00 | 0.00 | 0.00 | 0.499659E+09 | 0.328200E+09 | 0.00 | 0.00 | 4.59 |
May | 0.198974E+10 | 0.00 | 0.00 | 0.00 | 0.192651E+10 | 0.00 | 0.00 | 0.00 | 4.61 |
June | 0.757348E+09 | 0.00 | 0.00 | 0.00 | 0.527911E+10 | 0.00 | 0.00 | 0.00 | 4.62 |
July | 12617000.03 | 0.00 | 0.00 | 0.00 | 0.800564E+10 | 0.00 | 0.00 | 0.00 | 4.61 |
August | 309568.11 | 96199361.08 | 0.00 | 0.00 | 0.860623E+10 | 0.00 | 0.00 | 0.00 | 4.62 |
September | 0.123380E+10 | 0.102497E+09 | 0.00 | 0.00 | 0.394060E+10 | 0.00 | 0.00 | 0.00 | 4.63 |
October | 0.528596E+10 | 67444594.52 | 0.00 | 0.00 | 0.116315E+10 | 0.247871E+09 | 0.00 | 0.00 | 4.61 |
November | 0.623022E+10 | 0.00 | 0.00 | 4684.47 | 0.154695E+09 | 0.964224E+09 | 9794037.67 | 0.00 | 4.59 |
December | 0.554890E+10 | 0.00 | 0.00 | 0.00 | 19749833.17 | 0.331167E+10 | 0.00 | 0.00 | 4.57 |
Annual Sum or Average | 0.410579E+11 | 0.266476E+09 | 0.00 | 4684.47 | 0.296890E+11 | 0.131980E+11 | 9794037.67 | 0.00 | 4.60 |
Minimum of Months | 309568.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.55 |
Maximum of Months | 0.640977E+10 | 0.102497E+09 | 0.00 | 4684.47 | 0.860623E+10 | 0.482384E+10 | 9794037.67 | 0.00 | 4.63 |
Report: MechanicalVentilationLoadsMonthly
For: RETAIL_2_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.678755E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.91 |
February | 0.571547E+10 | 0.00 | 0.00 | 0.00 | 6179118.45 | 0.00 | 0.00 | 0.00 | 2.92 |
March | 0.519811E+10 | 0.00 | 0.00 | 0.00 | 63452361.80 | 0.00 | 0.00 | 0.00 | 2.93 |
April | 0.354398E+10 | 0.00 | 0.00 | 0.00 | 0.370216E+09 | 0.00 | 0.00 | 0.00 | 2.94 |
May | 0.147427E+10 | 0.00 | 0.00 | 0.00 | 0.142743E+10 | 0.00 | 0.00 | 0.00 | 2.95 |
June | 0.561148E+09 | 0.00 | 0.00 | 0.00 | 0.391149E+10 | 0.00 | 0.00 | 0.00 | 2.96 |
July | 9348416.81 | 0.00 | 0.00 | 0.00 | 0.593169E+10 | 0.00 | 0.00 | 0.00 | 2.95 |
August | 229370.83 | 0.00 | 0.00 | 0.00 | 0.644796E+10 | 0.00 | 0.00 | 0.00 | 2.96 |
September | 0.914171E+09 | 0.00 | 0.00 | 0.00 | 0.299569E+10 | 0.00 | 0.00 | 0.00 | 2.96 |
October | 0.410023E+10 | 0.00 | 0.00 | 0.00 | 0.911795E+09 | 0.00 | 0.00 | 0.00 | 2.95 |
November | 0.533790E+10 | 0.00 | 0.00 | 0.00 | 0.114619E+09 | 0.00 | 0.00 | 0.00 | 2.94 |
December | 0.656513E+10 | 0.00 | 0.00 | 0.00 | 14633405.08 | 0.00 | 0.00 | 0.00 | 2.92 |
Annual Sum or Average | 0.402075E+11 | 0.00 | 0.00 | 0.00 | 0.221952E+11 | 0.00 | 0.00 | 0.00 | 2.94 |
Minimum of Months | 229370.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.91 |
Maximum of Months | 0.678755E+10 | 0.00 | 0.00 | 0.00 | 0.644796E+10 | 0.00 | 0.00 | 0.00 | 2.96 |
Report: MechanicalVentilationLoadsMonthly
For: MECH_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.368962E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.346505E+10 | 0.00 | 0.00 | 1.45 |
February | 0.411491E+10 | 0.00 | 0.00 | 0.00 | 6513330.15 | 0.190969E+10 | 0.00 | 0.00 | 1.46 |
March | 0.547926E+10 | 0.00 | 0.00 | 0.00 | 66884327.32 | 0.00 | 0.00 | 0.00 | 1.46 |
April | 0.373566E+10 | 0.00 | 0.00 | 0.00 | 0.390240E+09 | 0.00 | 0.00 | 0.00 | 1.46 |
May | 0.155401E+10 | 0.00 | 0.00 | 0.00 | 0.150463E+10 | 0.00 | 0.00 | 0.00 | 1.47 |
June | 0.591499E+09 | 0.00 | 0.00 | 0.00 | 0.412305E+10 | 0.00 | 0.00 | 0.00 | 1.47 |
July | 9854047.23 | 0.00 | 0.00 | 0.00 | 0.625252E+10 | 0.00 | 0.00 | 0.00 | 1.47 |
August | 241776.87 | 0.00 | 0.00 | 0.00 | 0.679671E+10 | 0.00 | 0.00 | 0.00 | 1.47 |
September | 0.963616E+09 | 0.00 | 0.00 | 0.00 | 0.315772E+10 | 0.00 | 0.00 | 0.00 | 1.48 |
October | 0.432200E+10 | 0.00 | 0.00 | 0.00 | 0.961111E+09 | 0.00 | 0.00 | 0.00 | 1.47 |
November | 0.540812E+10 | 0.00 | 0.00 | 0.00 | 0.120819E+09 | 0.218488E+09 | 0.00 | 0.00 | 1.46 |
December | 0.576240E+10 | 0.00 | 0.00 | 0.00 | 15424886.13 | 0.115783E+10 | 0.00 | 0.00 | 1.46 |
Annual Sum or Average | 0.356312E+11 | 0.00 | 0.00 | 0.00 | 0.233956E+11 | 0.675106E+10 | 0.00 | 0.00 | 1.47 |
Minimum of Months | 241776.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.45 |
Maximum of Months | 0.576240E+10 | 0.00 | 0.00 | 0.00 | 0.679671E+10 | 0.346505E+10 | 0.00 | 0.00 | 1.48 |
Report: MechanicalVentilationLoadsMonthly
For: STORAGE_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.806663E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.276247E+10 | 0.00 | 0.00 | 1.25 |
February | 0.145915E+10 | 0.00 | 0.00 | 0.00 | 3249196.14 | 0.154625E+10 | 0.00 | 0.00 | 1.26 |
March | 0.250756E+10 | 0.00 | 0.00 | 0.00 | 33365466.37 | 0.225787E+09 | 0.00 | 0.00 | 1.26 |
April | 0.178845E+10 | 0.00 | 0.00 | 0.00 | 0.194673E+09 | 75096877.15 | 0.00 | 0.00 | 1.27 |
May | 0.775224E+09 | 0.00 | 0.00 | 0.00 | 0.750591E+09 | 0.00 | 0.00 | 0.00 | 1.27 |
June | 0.295071E+09 | 0.00 | 0.00 | 0.00 | 0.205680E+10 | 0.00 | 0.00 | 0.00 | 1.27 |
July | 4915723.83 | 0.00 | 0.00 | 0.00 | 0.311909E+10 | 0.00 | 0.00 | 0.00 | 1.27 |
August | 120611.19 | 0.00 | 0.00 | 0.00 | 0.339056E+10 | 0.00 | 0.00 | 0.00 | 1.27 |
September | 0.480703E+09 | 0.00 | 0.00 | 0.00 | 0.157524E+10 | 0.00 | 0.00 | 0.00 | 1.28 |
October | 0.211600E+10 | 0.00 | 0.00 | 0.00 | 0.479453E+09 | 40046458.91 | 0.00 | 0.00 | 1.27 |
November | 0.237275E+10 | 0.00 | 0.00 | 0.00 | 60270922.27 | 0.434101E+09 | 0.00 | 0.00 | 1.27 |
December | 0.169589E+10 | 0.00 | 0.00 | 0.00 | 7694755.11 | 0.175628E+10 | 0.00 | 0.00 | 1.26 |
Annual Sum or Average | 0.143025E+11 | 0.00 | 0.00 | 0.00 | 0.116710E+11 | 0.684003E+10 | 0.00 | 0.00 | 1.27 |
Minimum of Months | 120611.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.25 |
Maximum of Months | 0.250756E+10 | 0.00 | 0.00 | 0.00 | 0.339056E+10 | 0.276247E+10 | 0.00 | 0.00 | 1.28 |
Report: MechanicalVentilationLoadsMonthly
For: LAUNDRY_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.263700E+10 | 0.00 | 0.00 | 60782611.52 | 0.00 | 0.00 | 0.895179E+11 | 0.00 | 39.41 |
February | 0.168109E+10 | 82061350.98 | 0.00 | 55855774.40 | 1869183.07 | 0.00 | 0.759162E+11 | 0.00 | 39.56 |
March | 0.614516E+09 | 0.841206E+09 | 0.00 | 60225807.70 | 20778097.68 | 0.00 | 0.699525E+11 | 0.00 | 39.70 |
April | 0.436646E+09 | 0.490400E+10 | 0.00 | 46638168.10 | 0.125068E+09 | 0.00 | 0.476658E+11 | 0.00 | 39.77 |
May | 0.156361E+09 | 0.188153E+11 | 0.00 | 26634334.07 | 0.575373E+09 | 0.00 | 0.198449E+11 | 0.00 | 39.94 |
June | 43481736.62 | 0.512190E+11 | 0.00 | 9657206.66 | 0.191485E+10 | 0.00 | 0.756962E+10 | 0.00 | 39.99 |
July | 3111702.46 | 0.779776E+11 | 0.00 | 482612.54 | 0.259591E+10 | 0.00 | 0.123385E+09 | 0.00 | 39.90 |
August | 0.00 | 0.848410E+11 | 0.00 | 45874.56 | 0.274723E+10 | 0.00 | 3069653.36 | 0.00 | 39.99 |
September | 0.130001E+09 | 0.395967E+11 | 0.00 | 16658429.92 | 0.109723E+10 | 0.00 | 0.122733E+11 | 0.00 | 40.07 |
October | 0.515815E+09 | 0.121802E+11 | 0.00 | 49190216.89 | 0.206383E+09 | 0.00 | 0.551457E+11 | 0.00 | 39.87 |
November | 0.957909E+09 | 0.153056E+10 | 0.00 | 57763084.19 | 26387088.03 | 0.00 | 0.715128E+11 | 0.00 | 39.74 |
December | 0.196727E+10 | 0.196632E+09 | 0.00 | 61483865.28 | 2132872.64 | 0.00 | 0.871710E+11 | 0.00 | 39.55 |
Annual Sum or Average | 0.914320E+10 | 0.292184E+12 | 0.00 | 0.445418E+09 | 0.931321E+10 | 0.00 | 0.536696E+12 | 0.00 | 39.79 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 45874.56 | 0.00 | 0.00 | 3069653.36 | 0.00 | 39.41 |
Maximum of Months | 0.263700E+10 | 0.848410E+11 | 0.00 | 61483865.28 | 0.274723E+10 | 0.00 | 0.895179E+11 | 0.00 | 40.07 |
Report: MechanicalVentilationLoadsMonthly
For: CAFE_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.390919E+11 | 0.00 | 0.00 | 3676.70 | 0.00 | 0.411474E+09 | 50414584.56 | 0.00 | 6.98 |
February | 0.330435E+11 | 8627343.95 | 0.00 | 23003.44 | 27380851.84 | 57399408.91 | 0.205400E+09 | 0.00 | 7.01 |
March | 0.298043E+11 | 39257769.38 | 0.00 | 128690.12 | 0.330505E+09 | 0.00 | 0.486999E+09 | 0.00 | 7.04 |
April | 0.198499E+11 | 25229329.79 | 0.00 | 179335.24 | 0.213217E+10 | 0.00 | 0.802092E+09 | 0.00 | 7.05 |
May | 0.792448E+10 | 0.668174E+09 | 0.00 | 295285.49 | 0.765002E+10 | 0.00 | 0.666398E+09 | 0.00 | 7.08 |
June | 0.289598E+10 | 0.603140E+10 | 0.00 | 129149.38 | 0.167624E+11 | 0.00 | 0.373921E+09 | 0.00 | 7.10 |
July | 53838444.03 | 0.854891E+10 | 0.00 | 1227.89 | 0.260174E+11 | 0.00 | 637293.60 | 0.00 | 7.08 |
August | 29270.41 | 0.123809E+11 | 0.00 | 6139.77 | 0.251939E+11 | 0.00 | 1301225.42 | 0.00 | 7.10 |
September | 0.473613E+10 | 0.422302E+10 | 0.00 | 115408.81 | 0.132340E+11 | 0.00 | 0.590997E+09 | 0.00 | 7.11 |
October | 0.232286E+11 | 0.134034E+10 | 0.00 | 157465.36 | 0.397305E+10 | 0.00 | 0.664913E+09 | 0.00 | 7.07 |
November | 0.305691E+11 | 6179387.26 | 0.00 | 173617.45 | 0.661754E+09 | 0.00 | 0.536767E+09 | 0.00 | 7.04 |
December | 0.379820E+11 | 0.00 | 0.00 | 32282.38 | 85274706.96 | 0.00 | 0.275600E+09 | 0.00 | 7.01 |
Annual Sum or Average | 0.229180E+12 | 0.332720E+11 | 0.00 | 1245282.03 | 0.960680E+11 | 0.468873E+09 | 0.465544E+10 | 0.00 | 7.06 |
Minimum of Months | 29270.41 | 0.00 | 0.00 | 1227.89 | 0.00 | 0.00 | 637293.60 | 0.00 | 6.98 |
Maximum of Months | 0.390919E+11 | 0.123809E+11 | 0.00 | 295285.49 | 0.260174E+11 | 0.411474E+09 | 0.802092E+09 | 0.00 | 7.11 |
Report: MechanicalVentilationLoadsMonthly
For: LOBBY_FLR_1
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.131398E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.35 |
February | 0.110644E+12 | 0.00 | 0.00 | 0.00 | 0.119619E+09 | 0.00 | 0.00 | 0.00 | 3.36 |
March | 0.100628E+12 | 0.00 | 0.00 | 0.00 | 0.122835E+10 | 0.00 | 0.00 | 0.00 | 3.37 |
April | 0.686065E+11 | 0.00 | 0.00 | 0.00 | 0.716687E+10 | 0.00 | 0.00 | 0.00 | 3.38 |
May | 0.285398E+11 | 0.00 | 0.00 | 0.00 | 0.276330E+11 | 0.00 | 0.00 | 0.00 | 3.40 |
June | 0.108630E+11 | 0.00 | 0.00 | 0.00 | 0.757210E+11 | 0.00 | 0.00 | 0.00 | 3.40 |
July | 0.180972E+09 | 0.319069E+09 | 0.00 | 0.00 | 0.114510E+12 | 0.00 | 0.00 | 0.00 | 3.40 |
August | 4440299.11 | 0.443789E+09 | 0.00 | 0.00 | 0.124380E+12 | 0.00 | 0.00 | 0.00 | 3.40 |
September | 0.176971E+11 | 0.00 | 0.00 | 0.00 | 0.579923E+11 | 0.00 | 0.00 | 0.00 | 3.41 |
October | 0.793747E+11 | 0.00 | 0.00 | 0.00 | 0.176511E+11 | 0.00 | 0.00 | 0.00 | 3.39 |
November | 0.103334E+12 | 0.00 | 0.00 | 0.00 | 0.221887E+10 | 0.00 | 0.00 | 0.00 | 3.38 |
December | 0.127092E+12 | 0.00 | 0.00 | 0.00 | 0.283282E+09 | 0.00 | 0.00 | 0.00 | 3.36 |
Annual Sum or Average | 0.778362E+12 | 0.762858E+09 | 0.00 | 0.00 | 0.428904E+12 | 0.00 | 0.00 | 0.00 | 3.38 |
Minimum of Months | 4440299.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.35 |
Maximum of Months | 0.131398E+12 | 0.443789E+09 | 0.00 | 0.00 | 0.124380E+12 | 0.00 | 0.00 | 0.00 | 3.41 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_1_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.320423E+09 | 0.00 | 0.00 | 503373.10 | 0.00 | 0.106429E+10 | 92277643.73 | 0.00 | 0.47 |
February | 0.260565E+09 | 311187.47 | 0.00 | 1794486.99 | 77313.42 | 0.772949E+09 | 0.252483E+09 | 0.00 | 0.47 |
March | 0.297469E+09 | 18830224.00 | 15796.14 | 4936712.43 | 6013441.23 | 0.414011E+09 | 0.556011E+09 | 4093.95 | 0.47 |
April | 0.150343E+09 | 77722131.86 | 191311.22 | 5747034.06 | 20297550.90 | 0.115945E+09 | 0.586324E+09 | 19375.24 | 0.47 |
May | 37550845.92 | 0.353210E+09 | 336518.51 | 3598371.68 | 35315453.92 | 6317102.76 | 0.277286E+09 | 16949.35 | 0.47 |
June | 11845307.61 | 0.967106E+09 | 666082.97 | 1945007.57 | 55494584.06 | 138050.68 | 0.113008E+09 | 36771.48 | 0.48 |
July | 550406.18 | 0.139953E+10 | 1123372.94 | 76475.10 | 97825101.39 | 17822.70 | 459115.26 | 33484.55 | 0.47 |
August | 0.00 | 0.149754E+10 | 1143514.39 | 0.00 | 76001733.62 | 0.00 | 0.00 | 36558.71 | 0.48 |
September | 23176240.82 | 0.750513E+09 | 934033.93 | 1845589.14 | 80372223.50 | 8562586.06 | 0.157577E+09 | 30036.78 | 0.48 |
October | 0.202805E+09 | 0.206856E+09 | 366078.92 | 4899944.66 | 37202753.53 | 0.291228E+09 | 0.508091E+09 | 16421.16 | 0.47 |
November | 0.290844E+09 | 19629945.90 | 94892.86 | 3024149.83 | 11259662.57 | 0.556984E+09 | 0.453325E+09 | 9319.91 | 0.47 |
December | 0.388655E+09 | 1335202.56 | 6755.55 | 990652.00 | 1514907.79 | 0.945353E+09 | 0.163683E+09 | 1231.20 | 0.47 |
Annual Sum or Average | 0.198423E+10 | 0.529258E+10 | 4878357.44 | 29361796.55 | 0.421375E+09 | 0.417579E+10 | 0.316053E+10 | 204242.32 | 0.47 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.47 |
Maximum of Months | 0.388655E+09 | 0.149754E+10 | 1143514.39 | 5747034.06 | 97825101.39 | 0.106429E+10 | 0.586324E+09 | 36771.48 | 0.48 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_2_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.225117E+09 | 0.00 | 0.00 | 124660.62 | 0.00 | 0.121293E+10 | 39148688.21 | 0.00 | 0.47 |
February | 0.214457E+09 | 133974.94 | 1377.89 | 970790.36 | 252290.70 | 0.899812E+09 | 0.172401E+09 | 811.83 | 0.47 |
March | 0.326687E+09 | 16916510.94 | 31808.74 | 3277695.04 | 7907256.90 | 0.517956E+09 | 0.424357E+09 | 5065.62 | 0.47 |
April | 0.155121E+09 | 72237393.49 | 241235.94 | 4894869.18 | 25718027.76 | 0.147414E+09 | 0.550828E+09 | 22202.90 | 0.47 |
May | 38935273.01 | 0.346941E+09 | 382442.27 | 3426157.15 | 41491685.74 | 9263756.16 | 0.273089E+09 | 17946.60 | 0.47 |
June | 12053979.77 | 0.968191E+09 | 637625.67 | 1955970.55 | 54317382.61 | 138411.23 | 0.112773E+09 | 37832.14 | 0.48 |
July | 550341.70 | 0.140014E+10 | 1031188.10 | 76589.53 | 97136543.49 | 17820.61 | 458938.07 | 27912.13 | 0.47 |
August | 0.00 | 0.149259E+10 | 1142308.70 | 0.00 | 80762123.99 | 0.00 | 0.00 | 37626.13 | 0.48 |
September | 24131986.47 | 0.737849E+09 | 819475.89 | 1580497.79 | 93051751.26 | 9287612.12 | 0.156139E+09 | 31303.06 | 0.48 |
October | 0.224533E+09 | 0.189165E+09 | 528032.03 | 3082867.42 | 54695402.89 | 0.380223E+09 | 0.399068E+09 | 24610.23 | 0.47 |
November | 0.304425E+09 | 16919526.20 | 83072.44 | 1434567.62 | 13977917.63 | 0.730677E+09 | 0.267489E+09 | 9673.60 | 0.47 |
December | 0.341056E+09 | 572521.06 | 4125.20 | 304001.80 | 2276759.95 | 0.108869E+10 | 68454715.41 | 4356.02 | 0.47 |
Annual Sum or Average | 0.186707E+10 | 0.524166E+10 | 4902692.87 | 21128667.05 | 0.471587E+09 | 0.499641E+10 | 0.246421E+10 | 219340.28 | 0.47 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.47 |
Maximum of Months | 0.341056E+09 | 0.149259E+10 | 1142308.70 | 4894869.18 | 97136543.49 | 0.121293E+10 | 0.550828E+09 | 37832.14 | 0.48 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.158351E+11 | 0.00 | 0.00 | 5282646.33 | 0.00 | 0.265883E+10 | 0.153423E+10 | 0.00 | 0.53 |
February | 0.135289E+11 | 5267723.61 | 0.00 | 20680030.16 | 0.00 | 0.712574E+09 | 0.319911E+10 | 0.00 | 0.53 |
March | 0.895036E+10 | 0.337128E+09 | 0.00 | 38867215.25 | 0.00 | 0.00 | 0.826375E+10 | 0.00 | 0.54 |
April | 0.492259E+10 | 0.132956E+10 | 0.00 | 39199675.51 | 2356565.57 | 0.00 | 0.667679E+10 | 0.00 | 0.54 |
May | 0.162796E+10 | 0.525150E+10 | 0.00 | 21306273.88 | 21344199.70 | 0.00 | 0.275408E+10 | 0.00 | 0.54 |
June | 0.472271E+09 | 0.138751E+11 | 0.00 | 12064123.43 | 0.00 | 0.00 | 0.123681E+10 | 0.00 | 0.54 |
July | 3530755.06 | 0.202821E+11 | 0.00 | 307512.98 | 36404868.42 | 0.00 | 11128530.88 | 0.00 | 0.54 |
August | 0.00 | 0.213518E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.54 |
September | 0.795947E+09 | 0.112728E+11 | 0.00 | 14271126.40 | 6306087.85 | 0.00 | 0.178177E+10 | 0.00 | 0.54 |
October | 0.579055E+10 | 0.319245E+10 | 0.00 | 51842590.55 | 0.121957E+09 | 0.00 | 0.781196E+10 | 0.00 | 0.54 |
November | 0.902750E+10 | 0.420068E+09 | 0.00 | 46293968.96 | 180071.36 | 0.00 | 0.860968E+10 | 0.00 | 0.54 |
December | 0.154416E+11 | 38753233.35 | 0.00 | 20666034.25 | 0.00 | 0.00 | 0.485856E+10 | 0.00 | 0.53 |
Annual Sum or Average | 0.763963E+11 | 0.773565E+11 | 0.00 | 0.270781E+09 | 0.188548E+09 | 0.337140E+10 | 0.467379E+11 | 0.00 | 0.54 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.53 |
Maximum of Months | 0.158351E+11 | 0.213518E+11 | 0.00 | 51842590.55 | 0.121957E+09 | 0.265883E+10 | 0.860968E+10 | 0.00 | 0.54 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.535659E+10 | 0.00 | 0.00 | 10991800.52 | 0.00 | 0.969380E+10 | 0.497753E+10 | 0.00 | 0.53 |
February | 0.427435E+10 | 1367999.78 | 0.00 | 27803237.01 | 3901164.28 | 0.542296E+10 | 0.774097E+10 | 0.00 | 0.53 |
March | 0.449694E+10 | 0.187903E+09 | 592455.27 | 53984494.42 | 0.148675E+09 | 0.361596E+09 | 0.123452E+11 | 48726.83 | 0.54 |
April | 0.217341E+10 | 0.787884E+09 | 1074108.49 | 65552926.63 | 0.543261E+09 | 0.120310E+09 | 0.928249E+10 | 60959.44 | 0.54 |
May | 0.593722E+09 | 0.404723E+10 | 3894572.27 | 43230718.12 | 0.122309E+10 | 5452342.02 | 0.376214E+10 | 81850.24 | 0.54 |
June | 0.174783E+09 | 0.123631E+11 | 4681053.00 | 20348115.34 | 0.151100E+10 | 123484.67 | 0.152636E+10 | 40848.15 | 0.54 |
July | 7465054.97 | 0.179636E+11 | 4845722.16 | 1073759.27 | 0.235558E+10 | 0.00 | 6432077.33 | 38191.28 | 0.54 |
August | 0.00 | 0.189394E+11 | 3725637.28 | 0.00 | 0.241449E+10 | 0.00 | 0.00 | 26779.44 | 0.54 |
September | 0.334431E+09 | 0.895217E+10 | 12081093.81 | 23571334.97 | 0.231781E+10 | 2800131.04 | 0.223189E+10 | 150245.22 | 0.54 |
October | 0.311988E+10 | 0.222004E+10 | 2601073.27 | 53173561.69 | 0.109261E+10 | 0.168885E+09 | 0.103161E+11 | 60979.94 | 0.54 |
November | 0.433685E+10 | 0.221125E+09 | 954446.53 | 40741669.85 | 0.198240E+09 | 0.140702E+10 | 0.119037E+11 | 43603.40 | 0.54 |
December | 0.546928E+10 | 7853164.70 | 13438.10 | 20223982.93 | 30882882.93 | 0.569345E+10 | 0.914338E+10 | 14344.62 | 0.53 |
Annual Sum or Average | 0.303377E+11 | 0.656917E+11 | 34463600.18 | 0.360696E+09 | 0.118395E+11 | 0.228764E+11 | 0.732362E+11 | 566528.56 | 0.54 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.53 |
Maximum of Months | 0.546928E+10 | 0.189394E+11 | 12081093.81 | 65552926.63 | 0.241449E+10 | 0.969380E+10 | 0.123452E+11 | 150245.22 | 0.54 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_5_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.328832E+09 | 0.00 | 0.00 | 333886.15 | 0.00 | 0.106640E+10 | 81924131.14 | 0.00 | 0.47 |
February | 0.259971E+09 | 308997.49 | 1673.91 | 1976944.20 | 77313.42 | 0.758227E+09 | 0.267618E+09 | 516.07 | 0.47 |
March | 0.280508E+09 | 19489723.56 | 59169.04 | 4358982.26 | 5306902.68 | 0.402119E+09 | 0.585441E+09 | 7760.03 | 0.47 |
April | 0.127979E+09 | 79198104.96 | 207488.79 | 5970863.85 | 18803949.33 | 0.125882E+09 | 0.598527E+09 | 20826.13 | 0.47 |
May | 27866535.91 | 0.363373E+09 | 205664.62 | 4007327.16 | 25289081.60 | 12470134.99 | 0.280408E+09 | 11355.71 | 0.47 |
June | 4255769.09 | 0.988557E+09 | 79681.45 | 2178126.51 | 34663026.78 | 0.00 | 0.120503E+09 | 3357.13 | 0.48 |
July | 550406.18 | 0.142971E+10 | 422179.16 | 74977.18 | 68369596.19 | 17822.70 | 460613.17 | 7264.36 | 0.47 |
August | 0.00 | 0.152159E+10 | 105675.60 | 0.00 | 53024467.01 | 0.00 | 0.00 | 5008.83 | 0.48 |
September | 21570728.87 | 0.762949E+09 | 495779.46 | 2078232.30 | 68388409.90 | 9265681.06 | 0.158247E+09 | 15997.68 | 0.48 |
October | 0.177376E+09 | 0.211465E+09 | 336416.35 | 4711615.66 | 32630094.53 | 0.296126E+09 | 0.528812E+09 | 9631.71 | 0.47 |
November | 0.286564E+09 | 19048462.23 | 64259.44 | 2813736.96 | 11872082.81 | 0.542830E+09 | 0.471970E+09 | 9016.76 | 0.47 |
December | 0.395990E+09 | 1465357.83 | 7262.37 | 758246.41 | 1384752.52 | 0.921792E+09 | 0.180141E+09 | 724.38 | 0.47 |
Annual Sum or Average | 0.191146E+10 | 0.539716E+10 | 1985250.21 | 29262938.64 | 0.319810E+09 | 0.413513E+10 | 0.327405E+10 | 91458.77 | 0.47 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.47 |
Maximum of Months | 0.395990E+09 | 0.152159E+10 | 495779.46 | 5970863.85 | 68388409.90 | 0.106640E+10 | 0.598527E+09 | 20826.13 | 0.48 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_6_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.233446E+09 | 0.00 | 0.00 | 99246.52 | 0.00 | 0.120866E+10 | 35116494.93 | 0.00 | 0.47 |
February | 0.217690E+09 | 122675.20 | 2092.45 | 1017846.96 | 263590.44 | 0.882362E+09 | 0.186571E+09 | 97.27 | 0.47 |
March | 0.330116E+09 | 16646614.84 | 57795.69 | 2576827.28 | 8141484.13 | 0.497673E+09 | 0.441914E+09 | 14747.52 | 0.47 |
April | 0.149372E+09 | 73823089.79 | 269727.65 | 5037089.40 | 24098548.72 | 0.153986E+09 | 0.549864E+09 | 27493.93 | 0.47 |
May | 30458196.12 | 0.360509E+09 | 204666.86 | 3816390.91 | 28108426.34 | 15154535.03 | 0.275285E+09 | 11426.85 | 0.47 |
June | 4097953.43 | 0.989099E+09 | 80433.15 | 2194640.88 | 34001022.86 | 0.00 | 0.120629E+09 | 2595.71 | 0.48 |
July | 550341.70 | 0.142971E+10 | 422228.84 | 75088.44 | 68198683.47 | 17820.61 | 460439.16 | 7164.36 | 0.47 |
August | 0.00 | 0.151874E+10 | 105800.70 | 0.00 | 55684759.86 | 0.00 | 0.00 | 4870.76 | 0.48 |
September | 22064268.87 | 0.755163E+09 | 561801.92 | 1798997.44 | 76002875.92 | 9501631.34 | 0.157775E+09 | 24478.31 | 0.48 |
October | 0.228751E+09 | 0.201644E+09 | 512316.18 | 2749475.29 | 42231225.14 | 0.384200E+09 | 0.391207E+09 | 25366.54 | 0.47 |
November | 0.316972E+09 | 16258712.31 | 107658.38 | 1047571.94 | 14614748.78 | 0.704663E+09 | 0.281342E+09 | 9070.39 | 0.47 |
December | 0.349474E+09 | 578954.07 | 337.80 | 233652.69 | 2276759.95 | 0.109184E+10 | 56958614.31 | 1710.41 | 0.47 |
Annual Sum or Average | 0.188299E+10 | 0.536230E+10 | 2324859.63 | 20646827.76 | 0.353622E+09 | 0.494805E+10 | 0.249712E+10 | 129022.05 | 0.47 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.47 |
Maximum of Months | 0.349474E+09 | 0.151874E+10 | 561801.92 | 5037089.40 | 76002875.92 | 0.120866E+10 | 0.549864E+09 | 27493.93 | 0.48 |
Report: MechanicalVentilationLoadsMonthly
For: CORRIDOR_FLR_3
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.227558E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.879540E+10 | 0.00 | 0.00 | 0.88 |
February | 0.207675E+11 | 0.00 | 0.00 | 0.00 | 28722936.59 | 0.580021E+10 | 0.00 | 0.00 | 0.88 |
March | 0.239530E+11 | 0.00 | 0.00 | 0.00 | 0.294951E+09 | 0.209851E+09 | 0.00 | 0.00 | 0.88 |
April | 0.164738E+11 | 0.00 | 0.00 | 0.00 | 0.172091E+10 | 0.00 | 0.00 | 0.00 | 0.89 |
May | 0.685299E+10 | 0.00 | 0.00 | 0.00 | 0.663524E+10 | 0.00 | 0.00 | 0.00 | 0.89 |
June | 0.260843E+10 | 0.00 | 0.00 | 0.00 | 0.181821E+11 | 0.00 | 0.00 | 0.00 | 0.89 |
July | 43455063.27 | 0.00 | 0.00 | 0.00 | 0.275728E+11 | 0.00 | 0.00 | 0.00 | 0.89 |
August | 1066204.47 | 0.00 | 0.00 | 0.00 | 0.299726E+11 | 0.00 | 0.00 | 0.00 | 0.89 |
September | 0.424942E+10 | 0.00 | 0.00 | 0.00 | 0.139251E+11 | 0.00 | 0.00 | 0.00 | 0.89 |
October | 0.190594E+11 | 0.00 | 0.00 | 0.00 | 0.423837E+10 | 0.00 | 0.00 | 0.00 | 0.89 |
November | 0.244614E+11 | 0.00 | 0.00 | 0.00 | 0.532796E+09 | 0.351225E+09 | 0.00 | 0.00 | 0.88 |
December | 0.280974E+11 | 0.00 | 0.00 | 0.00 | 68021736.37 | 0.241985E+10 | 0.00 | 0.00 | 0.88 |
Annual Sum or Average | 0.169324E+12 | 0.00 | 0.00 | 0.00 | 0.103172E+12 | 0.175765E+11 | 0.00 | 0.00 | 0.89 |
Minimum of Months | 1066204.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.88 |
Maximum of Months | 0.280974E+11 | 0.00 | 0.00 | 0.00 | 0.299726E+11 | 0.879540E+10 | 0.00 | 0.00 | 0.89 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_1_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 66620768.63 | 0.00 | 0.00 | 82286.37 | 0.00 | 0.287507E+09 | 15162117.55 | 0.00 | 0.47 |
February | 56276626.34 | 77796.87 | 0.00 | 406869.57 | 19328.36 | 0.219500E+09 | 45764517.45 | 0.00 | 0.47 |
March | 71517092.70 | 4914574.67 | 3713.73 | 1192476.35 | 1296460.42 | 0.135516E+09 | 0.109881E+09 | 1140.01 | 0.47 |
April | 36624254.00 | 20545596.73 | 47486.39 | 1433765.75 | 3961136.84 | 47677053.94 | 0.128855E+09 | 3372.34 | 0.47 |
May | 8944867.26 | 90513084.64 | 51954.40 | 908986.57 | 6651852.12 | 5589307.54 | 65744841.10 | 2800.26 | 0.47 |
June | 2761306.33 | 0.243374E+09 | 167671.37 | 495936.02 | 12276418.17 | 37235.80 | 28439701.95 | 8042.25 | 0.48 |
July | 137601.55 | 0.352998E+09 | 278548.28 | 17451.36 | 21344702.82 | 4455.68 | 116446.23 | 6777.95 | 0.47 |
August | 0.00 | 0.376528E+09 | 282398.56 | 0.00 | 16861959.89 | 0.00 | 0.00 | 7924.05 | 0.48 |
September | 5767078.34 | 0.189840E+09 | 200834.80 | 426593.82 | 17915361.60 | 4079979.33 | 37516821.59 | 6490.02 | 0.48 |
October | 49757235.82 | 53607913.57 | 80789.89 | 1194519.12 | 7418349.96 | 96240377.59 | 0.104564E+09 | 3285.61 | 0.47 |
November | 70729413.56 | 5029462.29 | 23858.14 | 680949.63 | 2692939.82 | 0.173048E+09 | 81585699.50 | 2195.05 | 0.47 |
December | 86384812.92 | 335133.10 | 1712.92 | 188194.82 | 377394.49 | 0.262997E+09 | 25099943.25 | 283.77 | 0.47 |
Annual Sum or Average | 0.455521E+09 | 0.133776E+10 | 1138968.48 | 7028029.37 | 90815904.50 | 0.123220E+10 | 0.642730E+09 | 42311.32 | 0.47 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.47 |
Maximum of Months | 86384812.92 | 0.376528E+09 | 282398.56 | 1433765.75 | 21344702.82 | 0.287507E+09 | 0.128855E+09 | 8042.25 | 0.48 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_2_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 37289157.78 | 0.00 | 0.00 | 17353.42 | 0.00 | 0.326736E+09 | 5286529.51 | 0.00 | 0.47 |
February | 44261051.23 | 42912.38 | 0.00 | 215330.85 | 54201.46 | 0.250580E+09 | 26853871.57 | 0.00 | 0.47 |
March | 78192791.54 | 4430284.46 | 6046.19 | 774412.56 | 1777646.43 | 0.154383E+09 | 84719201.40 | 1183.47 | 0.47 |
April | 38269975.94 | 19746764.31 | 47450.52 | 1216957.62 | 4756436.12 | 53935202.40 | 0.121142E+09 | 4064.07 | 0.47 |
May | 9317042.77 | 90068897.67 | 51817.88 | 862301.94 | 7084654.80 | 6359524.18 | 64639621.23 | 2930.37 | 0.47 |
June | 2795126.49 | 0.243488E+09 | 152452.80 | 498253.88 | 12147790.64 | 37231.43 | 28399850.16 | 8027.77 | 0.48 |
July | 137585.42 | 0.353254E+09 | 252990.76 | 17447.81 | 21071690.76 | 4455.15 | 116434.10 | 5872.23 | 0.47 |
August | 0.00 | 0.375220E+09 | 270299.12 | 0.00 | 18135680.74 | 0.00 | 0.00 | 8239.72 | 0.48 |
September | 5952965.06 | 0.187858E+09 | 217219.24 | 359022.04 | 19855057.42 | 4202121.31 | 37270765.34 | 7629.14 | 0.48 |
October | 55143276.54 | 50051679.15 | 93640.83 | 738372.97 | 10953010.33 | 0.121614E+09 | 74231080.03 | 4848.75 | 0.47 |
November | 70951677.48 | 4307806.40 | 20987.32 | 300174.53 | 3416554.56 | 0.213068E+09 | 41686795.98 | 2199.19 | 0.47 |
December | 69102495.73 | 143130.26 | 718.35 | 50956.69 | 569189.99 | 0.294733E+09 | 10740353.71 | 1401.96 | 0.47 |
Annual Sum or Average | 0.411413E+09 | 0.132861E+10 | 1113623.00 | 5050584.29 | 99821913.24 | 0.142565E+10 | 0.495087E+09 | 46396.66 | 0.47 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.47 |
Maximum of Months | 78192791.54 | 0.375220E+09 | 270299.12 | 1216957.62 | 21071690.76 | 0.326736E+09 | 0.121142E+09 | 8239.72 | 0.48 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.453669E+09 | 0.00 | 0.00 | 3495410.91 | 0.00 | 0.139681E+10 | 0.519058E+09 | 0.00 | 0.53 |
February | 0.399697E+09 | 499805.14 | 0.00 | 5631384.62 | 124174.81 | 0.962523E+09 | 0.700500E+09 | 0.00 | 0.53 |
March | 0.366733E+09 | 33414837.01 | 17185.89 | 10278424.82 | 6500056.05 | 0.403038E+09 | 0.126363E+10 | 1832.59 | 0.54 |
April | 0.219473E+09 | 0.134876E+09 | 121404.01 | 9018495.58 | 22768289.65 | 0.144235E+09 | 0.100590E+10 | 4728.81 | 0.54 |
May | 57972768.49 | 0.575591E+09 | 244339.40 | 5212053.01 | 48733360.20 | 8683048.94 | 0.449724E+09 | 17948.96 | 0.54 |
June | 18038475.12 | 0.155021E+10 | 758844.46 | 2439029.80 | 92532327.94 | 92653.76 | 0.183306E+09 | 46913.59 | 0.54 |
July | 884019.67 | 0.225229E+10 | 1376009.62 | 110617.38 | 0.153101E+09 | 28625.44 | 749606.26 | 30554.53 | 0.54 |
August | 0.00 | 0.240397E+10 | 1265956.89 | 0.00 | 0.123931E+09 | 0.00 | 0.00 | 22572.76 | 0.54 |
September | 36510596.92 | 0.122564E+10 | 827631.27 | 3213484.08 | 0.109564E+09 | 2487719.84 | 0.264818E+09 | 22626.62 | 0.54 |
October | 0.241925E+09 | 0.356702E+09 | 115660.22 | 11374944.86 | 35782199.61 | 0.215725E+09 | 0.114838E+10 | 2729.15 | 0.54 |
November | 0.342247E+09 | 37481768.72 | 32824.83 | 10463097.71 | 12263589.09 | 0.507737E+09 | 0.123422E+10 | 1685.93 | 0.54 |
December | 0.457682E+09 | 2719775.53 | 0.00 | 5852591.39 | 1870678.06 | 0.107904E+10 | 0.864496E+09 | 0.00 | 0.53 |
Annual Sum or Average | 0.259483E+10 | 0.857340E+10 | 4759856.60 | 67089534.17 | 0.607170E+09 | 0.472039E+10 | 0.763478E+10 | 151592.94 | 0.54 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.53 |
Maximum of Months | 0.457682E+09 | 0.240397E+10 | 1376009.62 | 11374944.86 | 0.153101E+09 | 0.139681E+10 | 0.126363E+10 | 46913.59 | 0.54 |
Report: MechanicalVentilationLoadsMonthly
For: BANQUET_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.479926E+11 | 0.00 | 0.00 | 3055036.66 | 0.00 | 0.00 | 0.151161E+11 | 0.00 | 8.25 |
February | 0.344150E+11 | 3219579.25 | 0.00 | 4945436.39 | 54234849.85 | 0.00 | 0.187234E+11 | 0.00 | 8.29 |
March | 0.233812E+11 | 0.163476E+09 | 0.00 | 9813497.96 | 0.426514E+09 | 0.00 | 0.249418E+11 | 0.00 | 8.32 |
April | 0.122311E+11 | 0.110881E+10 | 0.00 | 11149090.68 | 0.233352E+10 | 0.00 | 0.207103E+11 | 0.00 | 8.34 |
May | 0.309555E+10 | 0.575530E+10 | 0.00 | 10695057.50 | 0.751715E+10 | 0.00 | 0.106018E+11 | 0.00 | 8.38 |
June | 0.833313E+09 | 0.219762E+11 | 0.00 | 4332932.94 | 0.143935E+11 | 0.00 | 0.438000E+10 | 0.00 | 8.40 |
July | 8862936.80 | 0.347468E+11 | 0.00 | 377302.37 | 0.204070E+11 | 0.00 | 77682831.65 | 0.00 | 8.38 |
August | 0.00 | 0.382313E+11 | 0.00 | 64740.27 | 0.217229E+11 | 0.00 | 2067986.28 | 0.00 | 8.40 |
September | 0.204783E+10 | 0.142420E+11 | 0.00 | 5039222.99 | 0.136124E+11 | 0.00 | 0.644724E+10 | 0.00 | 8.41 |
October | 0.176865E+11 | 0.410687E+10 | 0.00 | 8028592.28 | 0.437114E+10 | 0.00 | 0.204300E+11 | 0.00 | 8.36 |
November | 0.269645E+11 | 0.284664E+09 | 0.00 | 6708814.90 | 0.781086E+09 | 0.00 | 0.226614E+11 | 0.00 | 8.33 |
December | 0.398906E+11 | 0.00 | 0.00 | 4554389.14 | 0.136064E+09 | 0.00 | 0.211485E+11 | 0.00 | 8.29 |
Annual Sum or Average | 0.208547E+12 | 0.120619E+12 | 0.00 | 68764114.09 | 0.857555E+11 | 0.00 | 0.165240E+12 | 0.00 | 8.35 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 64740.27 | 0.00 | 0.00 | 2067986.28 | 0.00 | 8.25 |
Maximum of Months | 0.479926E+11 | 0.382313E+11 | 0.00 | 11149090.68 | 0.217229E+11 | 0.00 | 0.249418E+11 | 0.00 | 8.41 |
Report: MechanicalVentilationLoadsMonthly
For: DINING_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.471438E+11 | 0.00 | 0.00 | 4411917.00 | 0.00 | 0.00 | 0.190615E+11 | 0.00 | 8.66 |
February | 0.335891E+11 | 5943278.42 | 0.00 | 6738918.92 | 54331440.95 | 0.00 | 0.221562E+11 | 0.00 | 8.70 |
March | 0.221464E+11 | 0.198874E+09 | 0.00 | 12803379.98 | 0.420078E+09 | 0.00 | 0.285461E+11 | 0.00 | 8.73 |
April | 0.103705E+11 | 0.129565E+10 | 0.00 | 14177723.76 | 0.231566E+10 | 0.00 | 0.241853E+11 | 0.00 | 8.75 |
May | 0.240996E+10 | 0.729110E+10 | 0.00 | 13142128.91 | 0.663286E+10 | 0.00 | 0.119578E+11 | 0.00 | 8.80 |
June | 0.605394E+09 | 0.257810E+11 | 0.00 | 5268380.70 | 0.123740E+11 | 0.00 | 0.486310E+10 | 0.00 | 8.81 |
July | 3110035.35 | 0.413726E+11 | 0.00 | 457840.49 | 0.164885E+11 | 0.00 | 87622025.12 | 0.00 | 8.80 |
August | 0.00 | 0.446921E+11 | 0.00 | 73769.89 | 0.182050E+11 | 0.00 | 2163646.73 | 0.00 | 8.81 |
September | 0.189548E+10 | 0.171290E+11 | 0.00 | 6263150.68 | 0.120926E+11 | 0.00 | 0.701561E+10 | 0.00 | 8.82 |
October | 0.160704E+11 | 0.452093E+10 | 0.00 | 10437843.02 | 0.437324E+10 | 0.00 | 0.239152E+11 | 0.00 | 8.77 |
November | 0.262596E+11 | 0.429481E+09 | 0.00 | 8899560.38 | 0.688584E+09 | 0.00 | 0.258005E+11 | 0.00 | 8.74 |
December | 0.390755E+11 | 907657.32 | 0.00 | 6381958.27 | 0.141835E+09 | 0.00 | 0.249583E+11 | 0.00 | 8.69 |
Annual Sum or Average | 0.199569E+12 | 0.142718E+12 | 0.00 | 89056572.00 | 0.737867E+11 | 0.00 | 0.192550E+12 | 0.00 | 8.76 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 73769.89 | 0.00 | 0.00 | 2163646.73 | 0.00 | 8.66 |
Maximum of Months | 0.471438E+11 | 0.446921E+11 | 0.00 | 14177723.76 | 0.182050E+11 | 0.00 | 0.285461E+11 | 0.00 | 8.82 |
Report: MechanicalVentilationLoadsMonthly
For: KITCHEN_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 69529446.16 | 0.00 | 0.00 | 85264495.44 | 0.00 | 0.00 | 0.638617E+11 | 0.00 | 27.01 |
February | 76827125.49 | 58346388.20 | 0.00 | 79267562.28 | 0.00 | 0.00 | 0.537550E+11 | 0.00 | 27.13 |
March | 0.00 | 0.599703E+09 | 0.00 | 87161800.78 | 0.00 | 0.00 | 0.489558E+11 | 0.00 | 27.26 |
April | 0.00 | 0.349915E+10 | 0.00 | 64247855.12 | 0.00 | 0.00 | 0.333679E+11 | 0.00 | 27.33 |
May | 0.00 | 0.134937E+11 | 0.00 | 36228205.85 | 0.00 | 0.00 | 0.138694E+11 | 0.00 | 27.47 |
June | 0.00 | 0.369659E+11 | 0.00 | 13682476.38 | 0.00 | 0.00 | 0.527882E+10 | 0.00 | 27.52 |
July | 0.00 | 0.560593E+11 | 0.00 | 607849.69 | 0.00 | 0.00 | 87546981.94 | 0.00 | 27.46 |
August | 0.00 | 0.609354E+11 | 0.00 | 73326.21 | 0.00 | 0.00 | 2089622.57 | 0.00 | 27.52 |
September | 0.00 | 0.283035E+11 | 0.00 | 20708144.13 | 0.00 | 0.00 | 0.860265E+10 | 0.00 | 27.56 |
October | 0.00 | 0.861157E+10 | 0.00 | 71748543.56 | 0.00 | 0.00 | 0.386095E+11 | 0.00 | 27.38 |
November | 0.00 | 0.108297E+10 | 0.00 | 82842186.72 | 0.00 | 0.00 | 0.502750E+11 | 0.00 | 27.27 |
December | 5040363.38 | 0.138066E+09 | 0.00 | 88092988.65 | 0.00 | 0.00 | 0.618321E+11 | 0.00 | 27.12 |
Annual Sum or Average | 0.151397E+09 | 0.209748E+12 | 0.00 | 0.629925E+09 | 0.00 | 0.00 | 0.378498E+12 | 0.00 | 27.34 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 73326.21 | 0.00 | 0.00 | 2089622.57 | 0.00 | 27.01 |
Maximum of Months | 76827125.49 | 0.609354E+11 | 0.00 | 88092988.65 | 0.00 | 0.00 | 0.638617E+11 | 0.00 | 27.56 |
Report: MechanicalVentilationLoadsMonthly
For: CORRIDOR_FLR_6
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.689696E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.125823E+11 | 0.00 | 0.00 | 2.05 |
February | 0.880555E+10 | 0.00 | 0.00 | 0.00 | 17733152.59 | 0.759700E+10 | 0.00 | 0.00 | 2.05 |
March | 0.136867E+11 | 0.00 | 0.00 | 0.00 | 0.182099E+09 | 0.123111E+10 | 0.00 | 0.00 | 2.06 |
April | 0.962115E+10 | 0.00 | 0.00 | 0.00 | 0.106247E+10 | 0.549548E+09 | 0.00 | 0.00 | 2.07 |
May | 0.423094E+10 | 0.00 | 0.00 | 0.00 | 0.409651E+10 | 0.00 | 0.00 | 0.00 | 2.08 |
June | 0.161041E+10 | 0.00 | 0.00 | 0.00 | 0.112254E+11 | 0.00 | 0.00 | 0.00 | 2.08 |
July | 26828568.35 | 0.00 | 0.00 | 0.00 | 0.170231E+11 | 0.00 | 0.00 | 0.00 | 2.08 |
August | 658260.22 | 0.00 | 0.00 | 0.00 | 0.185047E+11 | 0.00 | 0.00 | 0.00 | 2.08 |
September | 0.262353E+10 | 0.00 | 0.00 | 0.00 | 0.859718E+10 | 0.00 | 0.00 | 0.00 | 2.08 |
October | 0.113388E+11 | 0.00 | 0.00 | 0.00 | 0.261672E+10 | 0.428236E+09 | 0.00 | 0.00 | 2.07 |
November | 0.128849E+11 | 0.00 | 0.00 | 0.00 | 0.328941E+09 | 0.243411E+10 | 0.00 | 0.00 | 2.06 |
December | 0.110674E+11 | 0.00 | 0.00 | 0.00 | 41995700.08 | 0.777350E+10 | 0.00 | 0.00 | 2.05 |
Annual Sum or Average | 0.827938E+11 | 0.00 | 0.00 | 0.00 | 0.636968E+11 | 0.325958E+11 | 0.00 | 0.00 | 2.07 |
Minimum of Months | 658260.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.05 |
Maximum of Months | 0.136867E+11 | 0.00 | 0.00 | 0.00 | 0.185047E+11 | 0.125823E+11 | 0.00 | 0.00 | 2.08 |
Report: HeatEmissionsReportMonthly
For: Environment
Timestamp: 2023-10-16 08:58:01
Custom Monthly ReportSITE TOTAL SURFACE HEAT EMISSION TO AIR [J] | SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] | SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] | AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] | HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J] | |
January | 0.182892E+12 | 0.267465E+11 | 0.111705E+12 | 0.138663E+13 | 0.125001E+12 |
February | 0.188711E+12 | 0.190065E+11 | 0.813935E+11 | 0.984008E+12 | 0.195020E+12 |
March | 0.276099E+12 | 0.125236E+11 | 0.598258E+11 | 0.647634E+12 | 0.406026E+12 |
April | 0.310541E+12 | 0.642261E+10 | 0.353430E+11 | 0.333643E+12 | 0.695514E+12 |
May | 0.340554E+12 | -0.187001E+10 | 0.416931E+10 | -0.112286E+12 | 0.121815E+13 |
June | 0.346158E+12 | -0.125713E+11 | -0.393295E+11 | -0.713125E+12 | 0.171473E+13 |
July | 0.321316E+12 | -0.207389E+11 | -0.708348E+11 | -0.117638E+13 | 0.212773E+13 |
August | 0.295988E+12 | -0.239366E+11 | -0.816168E+11 | -0.137151E+13 | 0.221127E+13 |
September | 0.222147E+12 | -0.878356E+10 | -0.223992E+11 | -0.504033E+12 | 0.148136E+13 |
October | 0.213604E+12 | 0.645177E+10 | 0.367311E+11 | 0.332945E+12 | 0.704503E+12 |
November | 0.149422E+12 | 0.139807E+11 | 0.640094E+11 | 0.742259E+12 | 0.336686E+12 |
December | 0.144491E+12 | 0.210704E+11 | 0.911957E+11 | 0.111108E+13 | 0.149457E+12 |
Annual Sum or Average | 0.299192E+13 | 0.383018E+11 | 0.270193E+12 | 0.166086E+13 | 0.113655E+14 |
Minimum of Months | 0.144491E+12 | -0.239366E+11 | -0.816168E+11 | -0.137151E+13 | 0.125001E+12 |
Maximum of Months | 0.346158E+12 | 0.267465E+11 | 0.111705E+12 | 0.138663E+13 | 0.221127E+13 |