Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 08:35
Tabular Output Report in Format: HTML
Building: OfficeMedium
Environment: RUNPERIOD 1 ** New Delhi-Safdarjung AP Delhi IND IWEC2 WMO#=421820
Simulation Timestamp: 2023-10-16 08:35:14
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 2103.91 | 422.29 | 422.29 |
Net Site Energy | 2103.91 | 422.29 | 422.29 |
Total Source Energy | 6473.00 | 1299.23 | 1299.23 |
Net Source Energy | 6473.00 | 1299.23 | 1299.23 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 1.200 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil No 1 | 1.050 |
Fuel Oil No 2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 4982.19 |
Net Conditioned Building Area | 4982.19 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 3.90 | 1.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 727.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 280.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 71.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 762.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 12.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 154.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 89.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 271.06 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 2012.66 | 91.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 271.06 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 3.90 | 1.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 727.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 280.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 71.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 641.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ElevatorLift | 120.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ElevatorLightsFan | 0.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Equipment | Transformer | 12.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 154.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 271.06 | |
Water Heater | 0.00 | 89.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | Unassigned | 3.90 | 1.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | Unassigned | 727.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GENERAL | 280.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | Unassigned | 71.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | GENERAL | 762.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | Unassigned | 12.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Unassigned | 154.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | Unassigned | 0.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Unassigned | 0.00 | 89.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 271.06 |
Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 70.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 177.68 | 18.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 |
Other | 155.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 403.97 | 18.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 70.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 177.68 | 18.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 |
Other | 155.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 403.97 | 18.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 2012.657 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 2012.657 | 100.00 |
Total On-Site and Utility Electric Sources | 2012.657 | 100.00 |
Total Electricity End Uses | 2012.657 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 271.06 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 271.06 | 100.00 |
Total Water End Uses | 271.06 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 41.50 |
Time Setpoint Not Met During Occupied Cooling | 579.83 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 1499.83 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Environment |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2018
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Environment |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME OFFICEMEDIUM
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 1B
| Environment |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY IND_DELHI_NEWDELHI
| Environment |ZoneCoolingSummaryMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |ZoneHeatingSummaryMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |ZoneElectricSummaryMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |SpaceGainsMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | FIRSTFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM |PeakSpaceGainsMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | FIRSTFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM |SpaceGainComponentsAtCoolingPeakMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |ComfortReportSimple55Monthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |OccupantComfortDataSummaryMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |DXReportMonthly
| PACU_VAV_BOT COOLING COIL | PACU_VAV_MID COOLING COIL | PACU_VAV_TOP COOLING COIL |WindowReportMonthly
| PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW |WindowEnergyReportMonthly
| PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW |WindowZoneSummaryMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |WindowEnergyZoneSummaryMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| SWHSYS1 WATER HEATER |DaylightingReportMonthly
| PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_4_DAYLCTRL |CoilReportMonthly
| CORE_BOTTOM VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | CORE_MID VAV BOX REHEAT COIL | PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | CORE_TOP VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | PACU_VAV_BOT HEATING COIL | PACU_VAV_MID HEATING COIL | PACU_VAV_TOP HEATING COIL | PACU_VAV_BOT COOLING COIL | PACU_VAV_MID COOLING COIL | PACU_VAV_TOP COOLING COIL |PlantLoopDemandReportMonthly
| SWHSYS1 |FanReportMonthly
| PACU_VAV_BOT FAN | PACU_VAV_MID FAN | PACU_VAV_TOP FAN |PumpReportMonthly
| SWHSYS1 PUMP |CondLoopDemandReportMonthly
| SWHSYS1 |ZoneTemperatureOscillationReportMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |AirLoopSystemEnergyAndWaterUseMonthly
| PACU_VAV_BOT | PACU_VAV_MID | PACU_VAV_TOP |AirLoopSystemComponentLoadsMonthly
| PACU_VAV_BOT | PACU_VAV_MID | PACU_VAV_TOP |AirLoopSystemComponentEnergyUseMonthly
| PACU_VAV_BOT | PACU_VAV_MID | PACU_VAV_TOP |MechanicalVentilationLoadsMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |HeatEmissionsReportMonthly
| Environment |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
GeneralValue | |
Program Version and Build | EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 08:35 |
RunPeriod | RUNPERIOD 1 |
Weather File | New Delhi-Safdarjung AP Delhi IND IWEC2 WMO#=421820 |
Latitude [deg] | 28.58 |
Longitude [deg] | 77.20 |
Elevation [m] | 216.00 |
Time Zone | 5.50 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1977.67 | 593.30 | 395.53 | 593.30 | 395.53 |
Above Ground Wall Area [m2] | 1977.67 | 593.30 | 395.53 | 593.30 | 395.53 |
Window Opening Area [m2] | 593.29 | 177.99 | 118.66 | 177.99 | 118.66 |
Gross Window-Wall Ratio [%] | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 |
Above Ground Window-Wall Ratio [%] | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1977.67 | 593.30 | 395.53 | 593.30 | 395.53 |
Above Ground Wall Area [m2] | 1977.67 | 593.30 | 395.53 | 593.30 | 395.53 |
Window Opening Area [m2] | 593.29 | 177.99 | 118.66 | 177.99 | 118.66 |
Gross Window-Wall Ratio [%] | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 |
Above Ground Window-Wall Ratio [%] | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 |
Total | |
Gross Roof Area [m2] | 1660.73 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
CORE_BOTTOM | 983.54 | Yes | Yes | 2698.04 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.5763 | 18.58 | 24.8342 |
TOPFLOOR_PLENUM | 1660.73 | Yes | No | 2024.76 | 1.00 | 202.84 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 | |
MIDFLOOR_PLENUM | 1660.73 | Yes | No | 2024.76 | 1.00 | 202.84 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 | |
FIRSTFLOOR_PLENUM | 1660.73 | Yes | No | 2024.76 | 1.00 | 202.84 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 | |
CORE_MID | 983.54 | Yes | Yes | 2698.04 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.5763 | 18.58 | 8.0700 |
CORE_TOP | 983.54 | Yes | Yes | 2698.04 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.5763 | 18.58 | 8.0700 |
PERIMETER_TOP_ZN_3 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 59.33 | 59.33 | 7.5763 | 18.58 | 8.0700 |
PERIMETER_TOP_ZN_2 | 131.26 | Yes | Yes | 360.08 | 1.00 | 91.28 | 0.00 | 39.55 | 39.55 | 7.5763 | 18.58 | 8.0695 |
PERIMETER_TOP_ZN_1 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 59.33 | 59.33 | 7.5763 | 18.58 | 8.0699 |
PERIMETER_TOP_ZN_4 | 131.25 | Yes | Yes | 360.05 | 1.00 | 91.28 | 0.00 | 39.55 | 39.55 | 7.5763 | 18.58 | 8.0700 |
PERIMETER_BOT_ZN_3 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 59.33 | 59.33 | 7.5763 | 18.58 | 8.0700 |
PERIMETER_BOT_ZN_2 | 131.26 | Yes | Yes | 360.08 | 1.00 | 91.28 | 0.00 | 39.55 | 39.55 | 7.5763 | 18.58 | 8.0695 |
PERIMETER_BOT_ZN_1 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 59.33 | 59.33 | 7.5763 | 18.58 | 8.0699 |
PERIMETER_BOT_ZN_4 | 131.25 | Yes | Yes | 360.05 | 1.00 | 91.28 | 0.00 | 39.55 | 39.55 | 7.5763 | 18.58 | 8.0700 |
PERIMETER_MID_ZN_3 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 59.33 | 59.33 | 7.5763 | 18.58 | 8.0700 |
PERIMETER_MID_ZN_2 | 131.26 | Yes | Yes | 360.08 | 1.00 | 91.28 | 0.00 | 39.55 | 39.55 | 7.5763 | 18.58 | 8.0695 |
PERIMETER_MID_ZN_1 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 59.33 | 59.33 | 7.5763 | 18.58 | 8.0699 |
PERIMETER_MID_ZN_4 | 131.25 | Yes | Yes | 360.05 | 1.00 | 91.28 | 0.00 | 39.55 | 39.55 | 7.5763 | 18.58 | 8.0700 |
Total | 4982.19 | 13667.13 | 1369.16 | 0.00 | 593.29 | 593.29 | 7.5763 | 18.58 | 11.3794 | |||
Conditioned Total | 4982.19 | 13667.13 | 1369.16 | 0.00 | 593.29 | 593.29 | 7.5763 | 18.58 | 11.3794 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 4982.19 | 6074.28 | 608.51 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
CORE_BOTTOM | 983.54 | Yes | Yes | 1.00 | CORE_BOTTOM | GENERAL | CORE_BOTTOM | 7.5763 | 18.58 | 24.8342 | |
TOPFLOOR_PLENUM | 1660.73 | Yes | No | 1.00 | TOPFLOOR_PLENUM | GENERAL | TOPFLOOR_PLENUM | 0.0000 | 0.00 | 0.0000 | |
MIDFLOOR_PLENUM | 1660.73 | Yes | No | 1.00 | MIDFLOOR_PLENUM | GENERAL | MIDFLOOR_PLENUM | 0.0000 | 0.00 | 0.0000 | |
FIRSTFLOOR_PLENUM | 1660.73 | Yes | No | 1.00 | FIRSTFLOOR_PLENUM | GENERAL | FIRSTFLOOR_PLENUM | 0.0000 | 0.00 | 0.0000 | |
CORE_MID | 983.54 | Yes | Yes | 1.00 | CORE_MID | GENERAL | CORE_MID | 7.5763 | 18.58 | 8.0700 | |
CORE_TOP | 983.54 | Yes | Yes | 1.00 | CORE_TOP | GENERAL | CORE_TOP | 7.5763 | 18.58 | 8.0700 | |
PERIMETER_TOP_ZN_3 | 207.34 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_3 | GENERAL | PERIMETER_TOP_ZN_3 | 7.5763 | 18.58 | 8.0700 | |
PERIMETER_TOP_ZN_2 | 131.26 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_2 | GENERAL | PERIMETER_TOP_ZN_2 | 7.5763 | 18.58 | 8.0695 | |
PERIMETER_TOP_ZN_1 | 207.34 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_1 | GENERAL | PERIMETER_TOP_ZN_1 | 7.5763 | 18.58 | 8.0699 | |
PERIMETER_TOP_ZN_4 | 131.25 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_4 | GENERAL | PERIMETER_TOP_ZN_4 | 7.5763 | 18.58 | 8.0700 | |
PERIMETER_BOT_ZN_3 | 207.34 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_3 | GENERAL | PERIMETER_BOT_ZN_3 | 7.5763 | 18.58 | 8.0700 | |
PERIMETER_BOT_ZN_2 | 131.26 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_2 | GENERAL | PERIMETER_BOT_ZN_2 | 7.5763 | 18.58 | 8.0695 | |
PERIMETER_BOT_ZN_1 | 207.34 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_1 | GENERAL | PERIMETER_BOT_ZN_1 | 7.5763 | 18.58 | 8.0699 | |
PERIMETER_BOT_ZN_4 | 131.25 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_4 | GENERAL | PERIMETER_BOT_ZN_4 | 7.5763 | 18.58 | 8.0700 | |
PERIMETER_MID_ZN_3 | 207.34 | Yes | Yes | 1.00 | PERIMETER_MID_ZN_3 | GENERAL | PERIMETER_MID_ZN_3 | 7.5763 | 18.58 | 8.0700 | |
PERIMETER_MID_ZN_2 | 131.26 | Yes | Yes | 1.00 | PERIMETER_MID_ZN_2 | GENERAL | PERIMETER_MID_ZN_2 | 7.5763 | 18.58 | 8.0695 | |
PERIMETER_MID_ZN_1 | 207.34 | Yes | Yes | 1.00 | PERIMETER_MID_ZN_1 | GENERAL | PERIMETER_MID_ZN_1 | 7.5763 | 18.58 | 8.0699 | |
PERIMETER_MID_ZN_4 | 131.25 | Yes | Yes | 1.00 | PERIMETER_MID_ZN_4 | GENERAL | PERIMETER_MID_ZN_4 | 7.5763 | 18.58 | 8.0700 | |
Total | 4982.19 | 7.5763 | 9.29 | 11.3794 | |||||||
Conditioned Total | 4982.19 | 7.5763 | 9.29 | 11.3794 | |||||||
Unconditioned Total | 0.00 | 0.0000 | 0.00 | 0.0000 | |||||||
Not Part of Total | 4982.19 | 0.0000 | 0.00 | 0.0000 |
Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
GENERAL | 4982.19 | 4982.19 | 0.00 | 4982.19 | 7.5763 | 18.58 | 11.3794 |
Total | 4982.19 | 4982.19 | 0.00 | 4982.19 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
End UsesElectricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 12-JUN-14:09 | 03-JAN-06:10 | - | - | - | - | - | - | - | - | - | - | 03-JAN-12:09 |
Heating | 0.00 | 13147.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 107227.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 23688.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 42286.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 919.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 26561.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 7785.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 200684.14 | 20932.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 13147.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 107227.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 23688.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 36185.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ElevatorLift | 6054.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ElevatorLightsFan | 46.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Equipment | Transformer | 919.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 26561.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Water Heater | 0.00 | 7785.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 12.34 | 1.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 2303.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 888.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 227.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 2413.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 41.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 487.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 97.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 6374.08 | 98.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 2.48 | 0.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 462.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 178.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 45.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 484.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 8.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 97.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 19.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1279.38 | 19.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 2.48 | 0.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 462.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 178.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 45.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 484.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 8.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 97.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 19.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1279.38 | 19.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
AirTerminal:SingleDuct:VAV:ReheatDesign Size Maximum Air Flow Rate [m3/s] | Design Size Constant Minimum Air Flow Fraction | User-Specified Constant Minimum Air Flow Fraction | Design Size Minimum Air Flow Rate [m3/s] | Design Size Maximum Flow Fraction during Reheat [] | User-Specified Maximum Flow Fraction during Reheat [] | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | |
CORE_BOTTOM VAV BOX COMPONENT | 2.94 | 0.255267 | 0.270000 | 0.792711 | 0.680711 | 0.500000 | 0.001493 |
CORE_MID VAV BOX COMPONENT | 2.21 | 0.339310 | 0.347000 | 0.766440 | 0.904827 | 0.500000 | 0.001123 |
CORE_TOP VAV BOX COMPONENT | 2.51 | 0.298779 | 0.322000 | 0.807704 | 0.796743 | 0.500000 | 0.001275 |
PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | 0.914132 | 0.172832 | 0.200000 | 0.182826 | 0.460886 | 0.500000 | 0.002204 |
PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | 0.691031 | 0.144743 | 0.200000 | 0.138206 | 0.385981 | 0.500000 | 0.002632 |
PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | 0.929167 | 0.170036 | 0.200000 | 0.185833 | 0.453429 | 0.500000 | 0.002241 |
PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | 0.769209 | 0.130023 | 0.200000 | 0.153842 | 0.346729 | 0.500000 | 0.002930 |
PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | 0.740157 | 0.213457 | 0.226000 | 0.167276 | 0.569218 | 0.500000 | 0.001785 |
PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | 0.596480 | 0.167687 | 0.200000 | 0.119296 | 0.447165 | 0.500000 | 0.002272 |
PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | 0.753638 | 0.209639 | 0.222000 | 0.167308 | 0.559036 | 0.500000 | 0.001817 |
PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | 0.620708 | 0.161131 | 0.200000 | 0.124142 | 0.429683 | 0.500000 | 0.002365 |
PERIMETER_MID_ZN_3 VAV BOX COMPONENT | 0.766691 | 0.206069 | 0.211000 | 0.161772 | 0.549518 | 0.500000 | 0.001849 |
PERIMETER_MID_ZN_2 VAV BOX COMPONENT | 0.629500 | 0.158891 | 0.200000 | 0.125900 | 0.423709 | 0.500000 | 0.002398 |
PERIMETER_MID_ZN_1 VAV BOX COMPONENT | 0.782411 | 0.201929 | 0.207000 | 0.161959 | 0.538478 | 0.500000 | 0.001887 |
PERIMETER_MID_ZN_4 VAV BOX COMPONENT | 0.665146 | 0.150366 | 0.200000 | 0.133029 | 0.400975 | 0.500000 | 0.002534 |
Design Size Nominal Capacity [W] | |
CORE_BOTTOM VAV BOX REHEAT COIL | 25807.74 |
CORE_MID VAV BOX REHEAT COIL | 24952.43 |
CORE_TOP VAV BOX REHEAT COIL | 26295.84 |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | 10498.13 |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | 6855.36 |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | 10490.86 |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | 6863.97 |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | 6309.14 |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | 4178.27 |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | 6309.14 |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | 4189.06 |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | 7441.59 |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | 4902.76 |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | 7432.94 |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | 4912.33 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PACU_VAV_BOT | 2.82 | 1.37 | 5.65 | 1.37 | 5.31 | 5.31 | 0.300000 | 0.258257 | 5.31 |
PACU_VAV_MID | 2.53 | 1.35 | 5.05 | 1.35 | 4.68 | 4.68 | 0.300000 | 0.288531 | 4.68 |
PACU_VAV_TOP | 2.91 | 1.47 | 5.81 | 1.85 | 5.71 | 5.71 | 0.300000 | 0.323741 | 5.71 |
Maximum Outdoor Air Flow Rate [m3/s] | |
PACU_VAV_BOT_OA_CONTROLLER | 5.31 |
PACU_VAV_MID_OA_CONTROLLER | 4.68 |
PACU_VAV_TOP_OA_CONTROLLER | 5.71 |
Design Size High Speed Rated Air Flow Rate [m3/s] | Design Size High Speed Gross Rated Total Cooling Capacity [W] | Design Size High Speed Rated Sensible Heat Ratio | Design Size Low Speed Rated Air Flow Rate [m3/s] | Design Size Low Speed Gross Rated Total Cooling Capacity [W] | Design Size Low Speed Gross Rated Sensible Heat Ratio | |
PACU_VAV_BOT COOLING COIL | 5.31 | 119051.26 | 0.734331 | 1.77 | 39679.79 | 0.734331 |
PACU_VAV_MID COOLING COIL | 4.68 | 107988.03 | 0.724516 | 1.56 | 35992.41 | 0.724516 |
PACU_VAV_TOP COOLING COIL | 5.71 | 126246.03 | 0.739252 | 1.90 | 42077.80 | 0.739252 |
Design Size Nominal Capacity [W] | |
PACU_VAV_BOT HEATING COIL | 5376.56 |
PACU_VAV_MID HEATING COIL | 7180.07 |
PACU_VAV_TOP HEATING COIL | 4155.39 |
Design Size Maximum Flow Rate [m3/s] | |
PACU_VAV_BOT FAN | 5.31 |
PACU_VAV_MID FAN | 4.68 |
PACU_VAV_TOP FAN | 5.71 |
Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
SWHSYS1 | 0.000054 | 0.006435 |
Design Flow Rate [m3/s] | Design Power Consumption [W] | |
SWHSYS1 PUMP | 0.000054 | 0.726125 |
Use Side Design Flow Rate [m3/s] | |
SWHSYS1 WATER HEATER | 0.000054 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
PERIMETER_TOP_ZN_3_WALL_NORTH | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | |
PERIMETER_TOP_ZN_2_WALL_EAST | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | |
PERIMETER_TOP_ZN_1_WALL_SOUTH | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | |
PERIMETER_TOP_ZN_4_WALL_WEST | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | |
PERIMETER_BOT_ZN_3_WALL_NORTH | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | |
PERIMETER_BOT_ZN_2_WALL_EAST | PERIMETER_BOT_ZN_2_WALL_EAST_DOOR | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | |
PERIMETER_BOT_ZN_1_WALL_SOUTH | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | |
PERIMETER_BOT_ZN_4_WALL_WEST | PERIMETER_BOT_ZN_4_WALL_WEST_DOOR | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | |
PERIMETER_MID_ZN_3_WALL_NORTH | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | |
PERIMETER_MID_ZN_2_WALL_EAST | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | |
PERIMETER_MID_ZN_1_WALL_SOUTH | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | |
PERIMETER_MID_ZN_4_WALL_WEST | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
VersionVersion ID | |
1 | 22.1 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 25.10 | 19.60 | 14.50 | 13.40 | 17.00 | 22.40 | 29.10 | 33.00 | 33.60 | 31.70 | 30.00 | 28.70 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | New Delhi-Safdarjung AP Delhi IND IWEC2 WMO#=421820 | 28.58 | 77.20 | 5.50 | 216.00 | 98757 | 1.1738 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 24.84 | 20.20 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | OfficeMedium | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 18 | 167 | 24 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | CORE_BOTTOM | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 1.37 | 1 | 1 | 1 | 4.57 | 45.34 | 4.57 | 28.70 | 0.00 | 2.74 | 2.74 | 2698.04 | TARP | TARP | 983.54 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
2 | TOPFLOOR_PLENUM | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 11.28 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 33.27 | 10.67 | 11.89 | 1.22 | 2024.76 | TARP | TARP | 1660.73 | 202.84 | 202.84 | 0.00 | 10 | 0 | 0 | No |
3 | MIDFLOOR_PLENUM | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 7.32 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 33.27 | 6.71 | 7.92 | 1.22 | 2024.76 | TARP | TARP | 1660.73 | 202.84 | 202.84 | 0.00 | 14 | 0 | 0 | No |
4 | FIRSTFLOOR_PLENUM | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 3.35 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 33.27 | 2.74 | 3.96 | 1.22 | 2024.76 | TARP | TARP | 1660.73 | 202.84 | 202.84 | 0.00 | 14 | 0 | 0 | No |
5 | CORE_MID | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 5.33 | 1 | 1 | 1 | 4.57 | 45.34 | 4.57 | 28.70 | 3.96 | 6.71 | 2.74 | 2698.04 | TARP | TARP | 983.54 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
6 | CORE_TOP | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 9.30 | 1 | 1 | 1 | 4.57 | 45.34 | 4.57 | 28.70 | 7.92 | 10.67 | 2.74 | 2698.04 | TARP | TARP | 983.54 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
7 | PERIMETER_TOP_ZN_3 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 31.11 | 9.30 | 1 | 1 | 1 | 0.00 | 49.91 | 28.70 | 33.27 | 7.92 | 10.67 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 77.59 | 59.33 | 6 | 1 | 0 | Yes |
8 | PERIMETER_TOP_ZN_2 | 0.0 | 0.00 | 0.00 | 0.00 | 47.82 | 16.64 | 9.30 | 1 | 1 | 1 | 45.34 | 49.91 | 0.00 | 33.27 | 7.92 | 10.67 | 2.74 | 360.08 | TARP | TARP | 131.26 | 91.28 | 51.72 | 39.55 | 6 | 1 | 0 | Yes |
9 | PERIMETER_TOP_ZN_1 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 2.16 | 9.30 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 4.57 | 7.92 | 10.67 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 77.59 | 59.33 | 6 | 1 | 0 | Yes |
10 | PERIMETER_TOP_ZN_4 | 0.0 | 0.00 | 0.00 | 0.00 | 2.09 | 16.64 | 9.30 | 1 | 1 | 1 | 0.00 | 4.57 | 0.00 | 33.27 | 7.92 | 10.67 | 2.74 | 360.05 | TARP | TARP | 131.25 | 91.28 | 51.72 | 39.55 | 6 | 1 | 0 | Yes |
11 | PERIMETER_BOT_ZN_3 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 31.11 | 1.37 | 1 | 1 | 1 | 0.00 | 49.91 | 28.70 | 33.27 | 0.00 | 2.74 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 73.69 | 59.33 | 6 | 5 | 0 | Yes |
12 | PERIMETER_BOT_ZN_2 | 0.0 | 0.00 | 0.00 | 0.00 | 47.82 | 16.64 | 1.37 | 1 | 1 | 1 | 45.34 | 49.91 | 0.00 | 33.27 | 0.00 | 2.74 | 2.74 | 360.08 | TARP | TARP | 131.26 | 91.28 | 49.77 | 39.55 | 6 | 3 | 0 | Yes |
13 | PERIMETER_BOT_ZN_1 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 2.16 | 1.37 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 4.57 | 0.00 | 2.74 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 73.69 | 59.33 | 6 | 5 | 0 | Yes |
14 | PERIMETER_BOT_ZN_4 | 0.0 | 0.00 | 0.00 | 0.00 | 2.09 | 16.64 | 1.37 | 1 | 1 | 1 | 0.00 | 4.57 | 0.00 | 33.27 | 0.00 | 2.74 | 2.74 | 360.05 | TARP | TARP | 131.25 | 91.28 | 49.77 | 39.55 | 6 | 3 | 0 | Yes |
15 | PERIMETER_MID_ZN_3 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 31.11 | 5.33 | 1 | 1 | 1 | 0.00 | 49.91 | 28.70 | 33.27 | 3.96 | 6.71 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 77.59 | 59.33 | 6 | 1 | 0 | Yes |
16 | PERIMETER_MID_ZN_2 | 0.0 | 0.00 | 0.00 | 0.00 | 47.82 | 16.64 | 5.33 | 1 | 1 | 1 | 45.34 | 49.91 | 0.00 | 33.27 | 3.96 | 6.71 | 2.74 | 360.08 | TARP | TARP | 131.26 | 91.28 | 51.72 | 39.55 | 6 | 1 | 0 | Yes |
17 | PERIMETER_MID_ZN_1 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 2.16 | 5.33 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 4.57 | 3.96 | 6.71 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 77.59 | 59.33 | 6 | 1 | 0 | Yes |
18 | PERIMETER_MID_ZN_4 | 0.0 | 0.00 | 0.00 | 0.00 | 2.09 | 16.64 | 5.33 | 1 | 1 | 1 | 0.00 | 4.57 | 0.00 | 33.27 | 3.96 | 6.71 | 2.74 | 360.05 | TARP | TARP | 131.25 | 91.28 | 51.72 | 39.55 | 6 | 1 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | CORE_BOTTOM | 983.54 | 52.9 | 18.579 | 5.382E-002 | 7.576 | 24.834 | 0.000 | 0.000 | 0.000 | 0.000 | 32.411 | No |
2 | TOPFLOOR_PLENUM | 1660.73 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
3 | MIDFLOOR_PLENUM | 1660.73 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
4 | FIRSTFLOOR_PLENUM | 1660.73 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
5 | CORE_MID | 983.54 | 52.9 | 18.579 | 5.382E-002 | 7.576 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 15.646 | No |
6 | CORE_TOP | 983.54 | 52.9 | 18.579 | 5.382E-002 | 7.576 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 15.646 | No |
7 | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 7.576 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 15.646 | No |
8 | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 18.579 | 5.382E-002 | 7.576 | 8.069 | 0.000 | 0.000 | 0.000 | 0.000 | 15.646 | No |
9 | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 7.576 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 15.646 | No |
10 | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 18.579 | 5.382E-002 | 7.576 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 15.646 | No |
11 | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 7.576 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 15.646 | No |
12 | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 18.579 | 5.382E-002 | 7.576 | 8.069 | 0.000 | 0.000 | 0.000 | 0.000 | 15.646 | No |
13 | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 7.576 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 15.646 | No |
14 | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 18.579 | 5.382E-002 | 7.576 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 15.646 | No |
15 | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 7.576 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 15.646 | No |
16 | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 18.579 | 5.382E-002 | 7.576 | 8.069 | 0.000 | 0.000 | 0.000 | 0.000 | 15.646 | No |
17 | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 7.576 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 15.646 | No |
18 | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 18.579 | 5.382E-002 | 7.576 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 15.646 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | Cooling Effect Calculation | Ankle Draft Calculation | |
1 | CORE_BOTTOM | BLDG_OCC_SCH_WO_SB | CORE_BOTTOM | 983.54 | 52.9 | 52.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 53 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
2 | CORE_MID | BLDG_OCC_SCH_WO_SB | CORE_MID | 983.54 | 52.9 | 52.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 53 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
3 | CORE_TOP | BLDG_OCC_SCH_WO_SB | CORE_TOP | 983.54 | 52.9 | 52.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 53 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
4 | PERIMETER_TOP_ZN_3 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
5 | PERIMETER_TOP_ZN_2 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
6 | PERIMETER_TOP_ZN_1 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
7 | PERIMETER_TOP_ZN_4 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
8 | PERIMETER_BOT_ZN_3 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
9 | PERIMETER_BOT_ZN_2 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
10 | PERIMETER_BOT_ZN_1 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
11 | PERIMETER_BOT_ZN_4 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
12 | PERIMETER_MID_ZN_3 | BLDG_OCC_SCH_WO_SB | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
13 | PERIMETER_MID_ZN_2 | BLDG_OCC_SCH_W_SB | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
14 | PERIMETER_MID_ZN_1 | BLDG_OCC_SCH_WO_SB | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
15 | PERIMETER_MID_ZN_4 | BLDG_OCC_SCH_WO_SB | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | CORE_BOTTOM_LIGHTS | LTG_SCH_OFFICE | CORE_BOTTOM | 983.54 | 52.9 | 7451.603 | 7.576 | 140.759 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 7451.603 |
2 | CORE_MID_LIGHTS | LTG_SCH_OFFICE | CORE_MID | 983.54 | 52.9 | 7451.603 | 7.576 | 140.759 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 7451.603 |
3 | CORE_TOP_LIGHTS | LTG_SCH_OFFICE | CORE_TOP | 983.54 | 52.9 | 7451.603 | 7.576 | 140.759 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 7451.603 |
4 | PERIMETER_TOP_ZN_3_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 1570.863 | 7.576 | 140.759 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1570.863 |
5 | PERIMETER_TOP_ZN_2_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 994.486 | 7.576 | 140.759 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 994.486 |
6 | PERIMETER_TOP_ZN_1_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 1570.863 | 7.576 | 140.759 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1570.863 |
7 | PERIMETER_TOP_ZN_4_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 994.421 | 7.576 | 140.759 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 994.421 |
8 | PERIMETER_BOT_ZN_3_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 1570.863 | 7.576 | 140.759 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1570.863 |
9 | PERIMETER_BOT_ZN_2_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 994.486 | 7.576 | 140.759 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 994.486 |
10 | PERIMETER_BOT_ZN_1_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 1570.863 | 7.576 | 140.759 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1570.863 |
11 | PERIMETER_BOT_ZN_4_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 994.421 | 7.576 | 140.759 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 994.421 |
12 | PERIMETER_MID_ZN_3_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 1570.863 | 7.576 | 140.759 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1570.863 |
13 | PERIMETER_MID_ZN_2_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 994.486 | 7.576 | 140.759 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 994.486 |
14 | PERIMETER_MID_ZN_1_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 1570.863 | 7.576 | 140.759 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1570.863 |
15 | PERIMETER_MID_ZN_4_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 994.421 | 7.576 | 140.759 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 994.421 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | CORE_BOTTOM_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_BOTTOM | 983.54 | 52.9 | 7937.156 | 8.070 | 149.931 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 7937.156 |
2 | CORE_MID_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_MID | 983.54 | 52.9 | 7937.156 | 8.070 | 149.931 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 7937.156 |
3 | CORE_TOP_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_TOP | 983.54 | 52.9 | 7937.156 | 8.070 | 149.931 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 7937.156 |
4 | PERIMETER_TOP_ZN_3_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 1673.214 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.214 |
5 | PERIMETER_TOP_ZN_2_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 1059.217 | 8.069 | 149.921 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.217 |
6 | PERIMETER_TOP_ZN_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 1673.203 | 8.070 | 149.929 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.203 |
7 | PERIMETER_TOP_ZN_4_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 1059.210 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.210 |
8 | PERIMETER_BOT_ZN_3_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 1673.214 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.214 |
9 | PERIMETER_BOT_ZN_2_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 1059.217 | 8.069 | 149.921 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.217 |
10 | PERIMETER_BOT_ZN_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 1673.203 | 8.070 | 149.929 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.203 |
11 | PERIMETER_BOT_ZN_4_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 1059.210 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.210 |
12 | PERIMETER_MID_ZN_3_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 1673.214 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.214 |
13 | PERIMETER_MID_ZN_2_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 1059.217 | 8.069 | 149.921 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.217 |
14 | PERIMETER_MID_ZN_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 1673.203 | 8.070 | 149.929 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.203 |
15 | PERIMETER_MID_ZN_4_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 1059.210 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.210 |
16 | CORE_BOTTOM_ELEVATORS_EQUIP | BLDG_ELEVATORS | CORE_BOTTOM | 983.54 | 52.9 | 16363.220 | 16.637 | 309.098 | 0.000 | 0.500 | 0.000 | 0.500 | ElevatorLift | 1963.586 | 11290.622 |
17 | ELEVATORS_LIGHTS_FAN | ELEV_LIGHT_FAN_SCH_ADD_DF | CORE_BOTTOM | 983.54 | 52.9 | 125.000 | 0.127 | 2.361 | 0.000 | 0.500 | 0.000 | 0.500 | ElevatorLightsFan | 0.000 | 86.250 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 3.464 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | INTERIORFURNISHINGS | 2 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
3 | DROPCEILING | 4 | 1 | 3 | 0.167 | 4.488 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
4 | INT_WALL | 7 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | INT_SLAB_FLOOR | 12 | 2 | 7 | 0.167 | 3.839 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
6 | INT_SLAB_CEILING | 13 | 2 | 7 | 0.167 | 3.839 | 0.900 | 0.900 | 0.700 | 0.700 | VeryRough |
7 | NONRES_ROOF | 17 | 3 | 3 | 0.167 | 0.2832 | 0.750 | 0.900 | 0.450 | 0.700 | Rough |
8 | NONRES_EXT_WALL_GRD | 20 | 4 | 7 | 0.167 | 1.029 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
9 | NONRES_EXT_WALL_MID | 21 | 4 | 7 | 0.167 | 1.013 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
10 | NONRES_EXT_WALL_TOP | 22 | 4 | 6 | 0.167 | 1.375 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
11 | PERIMETER_BOT_ZN_1_FLOOR_FFACTOR | 39 | 2 | 7 | 0.167 | 0.3192 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
12 | PERIMETER_BOT_ZN_2_FLOOR_FFACTOR | 40 | 2 | 7 | 0.167 | 0.3371 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
13 | PERIMETER_BOT_ZN_3_FLOOR_FFACTOR | 41 | 2 | 7 | 0.167 | 0.3192 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
14 | PERIMETER_BOT_ZN_4_FLOOR_FFACTOR | 42 | 2 | 7 | 0.167 | 0.3371 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
15 | CORE_BOT_ZN_5_FLOOR_FFACTOR | 43 | 2 | 8 | 0.167 | 0.5650E-02 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2887 |
2 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
3 | AC02 ACOUSTIC CEILING | 0.0127 | 0.057 | 288.000 | 1339.000 | 0.2228 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
6 | 100MM NORMALWEIGHT CONCRETE FLOOR | 0.1016 | 2.310 | 2322.000 | 832.000 | 0.4398E-01 |
7 | CP02 CARPET PAD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2165 |
8 | CP02 CARPET PAD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2165 |
9 | 100MM NORMALWEIGHT CONCRETE FLOOR | 0.1016 | 2.310 | 2322.000 | 832.000 | 0.4398E-01 |
10 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
11 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 3.472 |
12 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
13 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
14 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
15 | NONRES_EXTERIOR_WALL_INSULATION_GRD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.7377 |
16 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
17 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
18 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
19 | NONRES_EXTERIOR_WALL_INSULATION_MID | 0.0000 | 0.000 | 0.000 | 0.000 | 0.7531 |
20 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
21 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
22 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
23 | NONRES_EXTERIOR_WALL_INSULATION_TOP | 0.0000 | 0.000 | 0.000 | 0.000 | 0.4931 |
24 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
25 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.056 |
26 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
27 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 2.890 |
28 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
29 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.056 |
30 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
31 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 2.890 |
32 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
33 | ~FC_Insulation_5 | 0.0000 | 0.000 | 0.000 | 0.000 | 176.9 |
34 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 3.4637404 | 3.4637404 | 3.4637404 | |
3 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
4 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
5 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
6 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
7 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
8 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
9 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
10 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
11 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
12 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
13 | 3 | -0.21589802E-09 | 0.15643069E-09 | -0.21589802E-09 | 0.12999471E-21 |
14 | 2 | 0.50772448E-02 | 0.30006816E-02 | 0.50772448E-02 | -0.13693132E-08 |
15 | 1 | -2.5944910 | 1.4597758 | -2.5944910 | 0.76344767E-02 |
16 | 0 | 7.0433378 | 2.9911476 | 7.0433378 | |
17 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
18 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
19 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
20 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
21 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
22 | 7 | 0.43260499E-16 | 0.34524919E-16 | 0.52793240E-17 | 0.0000000 |
23 | 6 | 0.69434179E-09 | 0.98085174E-11 | 0.18162501E-10 | -0.40870994E-12 |
24 | 5 | -0.12888762E-04 | 0.28373718E-06 | -0.16918523E-06 | 0.92361873E-08 |
25 | 4 | 0.25174112E-01 | 0.33697681E-03 | 0.22646198E-03 | -0.31467795E-04 |
26 | 3 | -3.7600775 | 0.27170599E-01 | -0.48495626E-01 | 0.94171705E-02 |
27 | 2 | 51.553741 | 0.22121684 | 1.2284947 | -0.25833933 |
28 | 1 | -128.86110 | 0.21944682 | -5.1479470 | 1.1228340 |
29 | 0 | 81.526494 | 0.16043334E-01 | 4.4519351 | |
30 | 7 | 0.52793240E-17 | 0.34524919E-16 | 0.43260499E-16 | 0.0000000 |
31 | 6 | 0.18162501E-10 | 0.98085174E-11 | 0.69434179E-09 | -0.40870994E-12 |
32 | 5 | -0.16918523E-06 | 0.28373718E-06 | -0.12888762E-04 | 0.92361873E-08 |
33 | 4 | 0.22646198E-03 | 0.33697681E-03 | 0.25174112E-01 | -0.31467795E-04 |
34 | 3 | -0.48495626E-01 | 0.27170599E-01 | -3.7600775 | 0.94171705E-02 |
35 | 2 | 1.2284947 | 0.22121684 | 51.553741 | -0.25833933 |
36 | 1 | -5.1479470 | 0.21944682 | -128.86110 | 1.1228340 |
37 | 0 | 4.4519351 | 0.16043334E-01 | 81.526494 | |
38 | 3 | -0.61927053E-06 | 0.12767249E-08 | -0.37968499E-05 | 0.16832131E-17 |
39 | 2 | 0.77611055 | 0.17315568E-02 | 1.0534842 | -0.72792597E-06 |
40 | 1 | -21.915918 | 0.11588205 | -6.3286394 | 0.20197014 |
41 | 0 | 21.365777 | 0.10835518 | 5.5011278 | |
42 | 7 | -0.27613173E-12 | 0.13648587E-14 | -0.80406974E-13 | 0.78369587E-16 |
43 | 6 | 0.25651297E-07 | 0.27955499E-09 | 0.59014154E-08 | -0.11905989E-12 |
44 | 5 | -0.17465063E-03 | 0.24416492E-05 | -0.90019538E-04 | 0.58421144E-08 |
45 | 4 | 0.27387862 | 0.12098825E-02 | 0.93122264E-01 | -0.31012301E-04 |
46 | 3 | -6.9041115 | 0.38080793E-01 | -2.2314619 | 0.27235146E-01 |
47 | 2 | 39.676056 | 0.13726811 | 14.823303 | -0.32003278 |
48 | 1 | -79.629469 | 0.62686726E-01 | -28.745292 | 1.0590931 |
49 | 0 | 46.824345 | 0.12759187E-02 | 16.300942 | |
50 | 7 | -0.27182421E-12 | 0.13107754E-14 | -0.81108189E-13 | 0.79120162E-16 |
51 | 6 | 0.25844325E-07 | 0.27588229E-09 | 0.59440225E-08 | -0.12008605E-12 |
52 | 5 | -0.17564658E-03 | 0.24062150E-05 | -0.90521036E-04 | 0.58837691E-08 |
53 | 4 | 0.27506755 | 0.11908598E-02 | 0.93548701E-01 | -0.31177608E-04 |
54 | 3 | -6.9277136 | 0.37441415E-01 | -2.2384615 | 0.27350651E-01 |
55 | 2 | 39.753961 | 0.13483533 | 14.852153 | -0.32090009 |
56 | 1 | -79.689237 | 0.61525268E-01 | -28.771196 | 1.0603666 |
57 | 0 | 46.824344 | 0.12512697E-02 | 16.300293 | |
58 | 6 | 0.21465343E-07 | 0.35044740E-09 | 0.49771822E-08 | -0.96989815E-13 |
59 | 5 | -0.15274237E-03 | 0.31655188E-05 | -0.78941554E-04 | 0.49363227E-08 |
60 | 4 | 0.24727258 | 0.16154212E-02 | 0.83601931E-01 | -0.27359285E-04 |
61 | 3 | -6.3748395 | 0.52179222E-01 | -2.0745682 | 0.24648141E-01 |
62 | 2 | 37.927790 | 0.19236366 | 14.173893 | -0.30057625 |
63 | 1 | -78.286849 | 0.89555956E-01 | -28.161423 | 1.0304865 |
64 | 0 | 46.824354 | 0.18576719E-02 | 16.316151 | |
65 | 7 | -0.13059908E-08 | -0.16504735E-15 | 0.90649122E-14 | -0.12541312E-15 |
66 | 6 | 0.89164571E-05 | 0.61445766E-08 | 0.31804070E-02 | -0.26679919E-04 |
67 | 5 | -0.64531733E-03 | 0.36428408E-05 | -0.22318667 | 0.19514025E-02 |
68 | 4 | 0.14868215E-01 | 0.16589759E-03 | 4.8205855 | -0.45178851E-01 |
69 | 3 | -0.13063200 | 0.13198961E-02 | -37.970795 | 0.39809422 |
70 | 2 | 0.46393162 | 0.21965806E-02 | 116.38542 | -1.4166214 |
71 | 1 | -0.66966470 | 0.66967549E-03 | -143.84930 | 2.0480865 |
72 | 0 | 0.32650513 | 0.16166393E-04 | 60.838472 | |
73 | 7 | -0.12346633E-08 | -0.14425327E-15 | 0.91357699E-14 | -0.10087110E-15 |
74 | 6 | 0.94177090E-05 | 0.64929528E-08 | 0.31789869E-02 | -0.26668006E-04 |
75 | 5 | -0.68205191E-03 | 0.38502154E-05 | -0.22310594 | 0.19506899E-02 |
76 | 4 | 0.15716902E-01 | 0.17535208E-03 | 4.8192406 | -0.45165923E-01 |
77 | 3 | -0.13809356 | 0.13952366E-02 | -37.963195 | 0.39801023 |
78 | 2 | 0.49043520 | 0.23220647E-02 | 116.37063 | -1.4164235 |
79 | 1 | -0.70792287 | 0.70803996E-03 | -143.84059 | 2.0479434 |
80 | 0 | 0.34515858 | 0.17069463E-04 | 60.838472 | |
81 | 7 | -0.13059908E-08 | -0.16504702E-15 | 0.90649122E-14 | -0.12541312E-15 |
82 | 6 | 0.89164571E-05 | 0.61445766E-08 | 0.31804070E-02 | -0.26679919E-04 |
83 | 5 | -0.64531733E-03 | 0.36428408E-05 | -0.22318667 | 0.19514025E-02 |
84 | 4 | 0.14868215E-01 | 0.16589759E-03 | 4.8205855 | -0.45178851E-01 |
85 | 3 | -0.13063200 | 0.13198961E-02 | -37.970795 | 0.39809422 |
86 | 2 | 0.46393162 | 0.21965806E-02 | 116.38542 | -1.4166214 |
87 | 1 | -0.66966470 | 0.66967549E-03 | -143.84930 | 2.0480865 |
88 | 0 | 0.32650513 | 0.16166393E-04 | 60.838472 | |
89 | 7 | -0.12345751E-08 | -0.14398051E-15 | 0.92894684E-14 | -0.10085648E-15 |
90 | 6 | 0.94183649E-05 | 0.64934092E-08 | 0.31789851E-02 | -0.26667991E-04 |
91 | 5 | -0.68209995E-03 | 0.38504865E-05 | -0.22310583 | 0.19506890E-02 |
92 | 4 | 0.15718012E-01 | 0.17536444E-03 | 4.8192388 | -0.45165906E-01 |
93 | 3 | -0.13810332 | 0.13953351E-02 | -37.963185 | 0.39801012 |
94 | 2 | 0.49046985 | 0.23222288E-02 | 116.37061 | -1.4164232 |
95 | 1 | -0.70797289 | 0.70809005E-03 | -143.84058 | 2.0479432 |
96 | 0 | 0.34518296 | 0.17070678E-04 | 60.838472 | |
97 | 8 | 0.57026216E-10 | -0.29656739E-13 | 0.26072253E-13 | -0.16907584E-15 |
98 | 7 | -0.80728763E-07 | 0.14958947E-11 | -0.10196182E-04 | 0.85534123E-07 |
99 | 6 | 0.59163330E-05 | 0.23390251E-08 | 0.39199948E-02 | -0.33137873E-04 |
100 | 5 | -0.14678961E-03 | 0.29443049E-06 | -0.24001665 | 0.21083805E-02 |
101 | 4 | 0.15257864E-02 | 0.63469284E-05 | 4.9653291 | -0.46676227E-01 |
102 | 3 | -0.74362311E-02 | 0.30151767E-04 | -38.474208 | 0.40407555 |
103 | 2 | 0.17883035E-01 | 0.32406056E-04 | 117.10039 | -1.4265819 |
104 | 1 | -0.20235698E-01 | 0.62001922E-05 | -144.19380 | 2.0537490 |
105 | 0 | 0.84795330E-02 | 0.69040512E-07 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | Conductance (Before Adjusted) {W/m2-K} | Convection Coefficient Adjustment Ratio | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | WINDOW_U_0.5047_SHGC_EAST_0.25 | 35 | 1 | VerySmooth | 2.869 | 2.869 | 1.000 | 0.251 | ||
2 | WINDOW_U_0.5047_SHGC_SOUTH_0.25 | 36 | 1 | VerySmooth | 2.869 | 2.869 | 1.000 | 0.251 | ||
3 | WINDOW_U_0.5047_SHGC_WEST_0.25 | 37 | 1 | VerySmooth | 2.869 | 2.869 | 1.000 | 0.251 | ||
4 | WINDOW_U_0.5047_SHGC_NORTH_0.25 | 38 | 1 | VerySmooth | 2.869 | 2.869 | 1.000 | 0.251 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | GLAZING LAYER EAST | SpectralAverage | 1.90891E-002 | 0.16139 | 0.61055 | 0.61055 | 0.25000 | 0.16143 | 0.23877 | 0.00000 | 0.84000 | 0.84000 | 0.10708 | 1.00000 | No | |
2 | GLAZING LAYER SOUTH | SpectralAverage | 1.90891E-002 | 0.16139 | 0.61055 | 0.61055 | 0.25000 | 0.16143 | 0.23877 | 0.00000 | 0.84000 | 0.84000 | 0.10708 | 1.00000 | No | |
3 | GLAZING LAYER WEST | SpectralAverage | 1.90891E-002 | 0.16139 | 0.61055 | 0.61055 | 0.25000 | 0.16143 | 0.23877 | 0.00000 | 0.84000 | 0.84000 | 0.10708 | 1.00000 | No | |
4 | GLAZING LAYER NORTH | SpectralAverage | 1.90891E-002 | 0.16139 | 0.61055 | 0.61055 | 0.25000 | 0.16143 | 0.23877 | 0.00000 | 0.84000 | 0.84000 | 0.10708 | 1.00000 | No |
Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | PolygonClipping | Periodic | 30 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
Enclosure Name | Number of Exterior Windows | Number of Exterior Windows in Adjacent Enclosures | |
1 | PERIMETER_TOP_ZN_3 | 1 | 0 |
2 | PERIMETER_TOP_ZN_2 | 1 | 0 |
3 | PERIMETER_TOP_ZN_1 | 1 | 0 |
4 | PERIMETER_TOP_ZN_4 | 1 | 0 |
5 | PERIMETER_BOT_ZN_3 | 3 | 0 |
6 | PERIMETER_BOT_ZN_2 | 2 | 0 |
7 | PERIMETER_BOT_ZN_1 | 3 | 0 |
8 | PERIMETER_BOT_ZN_4 | 2 | 0 |
9 | PERIMETER_MID_ZN_3 | 1 | 0 |
10 | PERIMETER_MID_ZN_2 | 1 | 0 |
11 | PERIMETER_MID_ZN_1 | 1 | 0 |
12 | PERIMETER_MID_ZN_4 | 1 | 0 |
Enclosure Name | Number of Adjacent Enclosures with Windows | Adjacent Enclosure Names - 1st 100 (max) | |
1 | PERIMETER_TOP_ZN_3 | 0 | |
2 | PERIMETER_TOP_ZN_2 | 0 | |
3 | PERIMETER_TOP_ZN_1 | 0 | |
4 | PERIMETER_TOP_ZN_4 | 0 | |
5 | PERIMETER_BOT_ZN_3 | 0 | |
6 | PERIMETER_BOT_ZN_2 | 0 | |
7 | PERIMETER_BOT_ZN_1 | 0 | |
8 | PERIMETER_BOT_ZN_4 | 0 | |
9 | PERIMETER_MID_ZN_3 | 0 | |
10 | PERIMETER_MID_ZN_2 | 0 | |
11 | PERIMETER_MID_ZN_1 | 0 | |
12 | PERIMETER_MID_ZN_4 | 0 |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | 0.3785 | 29307.1 | 1.024 | 0.2440 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | CORE_BOT_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
2 | CORE_BOT_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
3 | CORE_BOT_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
4 | CORE_BOT_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
5 | CORE_BOT_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
6 | CORE_BOT_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
7 | CORE_BOTTOM_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
8 | PERIMETER_TOP_PLENUM_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
9 | PERIMETER_TOP_PLENUM_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
10 | PERIMETER_TOP_PLENUM_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
11 | PERIMETER_TOP_PLENUM_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
12 | iz-PERIMETER_TOP_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
13 | iz-PERIMETER_TOP_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
14 | iz-PERIMETER_TOP_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
15 | iz-PERIMETER_TOP_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
16 | iz-CORE_TOP_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
17 | BUILDING_ROOF | 0 | 1660.73 | 183.01 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
18 | PERIMETER_MID_PLENUM_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
19 | PERIMETER_MID_PLENUM_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
20 | PERIMETER_MID_PLENUM_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
21 | PERIMETER_MID_PLENUM_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
22 | iz-PERIMETER_MID_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
23 | iz-PERIMETER_MID_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
24 | iz-PERIMETER_MID_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
25 | iz-PERIMETER_MID_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
26 | iz-CORE_MID_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
27 | iz-PERIMETER_TOP_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
28 | iz-PERIMETER_TOP_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
29 | iz-PERIMETER_TOP_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
30 | iz-PERIMETER_TOP_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
31 | iz-CORE_TOP_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
32 | PERIMETER_BOT_PLENUM_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
33 | PERIMETER_BOT_PLENUM_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
34 | PERIMETER_BOT_PLENUM_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
35 | PERIMETER_BOT_PLENUM_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
36 | iz-PERIMETER_BOT_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
37 | iz-PERIMETER_BOT_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
38 | iz-PERIMETER_BOT_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
39 | iz-PERIMETER_BOT_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
40 | iz-CORE_BOT_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
41 | iz-PERIMETER_MID_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
42 | iz-PERIMETER_MID_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
43 | iz-PERIMETER_MID_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
44 | iz-PERIMETER_MID_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
45 | iz-CORE_MID_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
46 | CORE_MID_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
47 | CORE_MID_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
48 | CORE_MID_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
49 | CORE_MID_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
50 | CORE_MID_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
51 | CORE_MID_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
52 | CORE_MID_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
53 | CORE_TOP_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
54 | CORE_TOP_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
55 | CORE_TOP_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
56 | CORE_TOP_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
57 | CORE_TOP_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
58 | CORE_TOP_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
59 | CORE_TOP_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
60 | PERIMETER_TOP_ZN_3_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 3 | No | No |
61 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
62 | PERIMETER_TOP_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
63 | iz-PERIMETER_TOP_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
64 | iz-CORE_TOP_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
65 | PERIMETER_TOP_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
66 | PERIMETER_TOP_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
67 | PERIMETER_TOP_ZN_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
68 | PERIMETER_TOP_ZN_2_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 3 | No | No |
69 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 2 | No | No |
70 | PERIMETER_TOP_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
71 | iz-PERIMETER_TOP_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
72 | iz-CORE_TOP_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
73 | PERIMETER_TOP_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
74 | PERIMETER_TOP_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
75 | PERIMETER_TOP_ZN_2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
76 | PERIMETER_TOP_ZN_1_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 3 | No | No |
77 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
78 | PERIMETER_TOP_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
79 | iz-PERIMETER_TOP_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
80 | iz-CORE_TOP_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
81 | PERIMETER_TOP_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
82 | PERIMETER_TOP_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
83 | PERIMETER_TOP_ZN_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
84 | PERIMETER_TOP_ZN_4_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 3 | No | No |
85 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 2 | No | No |
86 | PERIMETER_TOP_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
87 | iz-PERIMETER_TOP_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
88 | iz-CORE_TOP_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
89 | PERIMETER_TOP_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
90 | PERIMETER_TOP_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
91 | PERIMETER_TOP_ZN_4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
92 | PERIMETER_BOT_ZN_3_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 3 | No | No |
93 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
94 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
95 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
96 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
97 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
98 | PERIMETER_BOT_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
99 | iz-PERIMETER_BOT_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
100 | iz-CORE_BOT_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
101 | PERIMETER_BOT_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
102 | PERIMETER_BOT_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
103 | PERIMETER_BOT_ZN_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
104 | PERIMETER_BOT_ZN_2_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 3 | No | No |
105 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 2 | No | No |
106 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 2 | No | No |
107 | PERIMETER_BOT_ZN_2_WALL_EAST_DOOR | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
108 | PERIMETER_BOT_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
109 | iz-PERIMETER_BOT_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
110 | iz-CORE_BOT_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
111 | PERIMETER_BOT_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
112 | PERIMETER_BOT_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
113 | PERIMETER_BOT_ZN_2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
114 | PERIMETER_BOT_ZN_1_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 3 | No | No |
115 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
116 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
117 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
118 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
119 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
120 | PERIMETER_BOT_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
121 | iz-PERIMETER_BOT_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
122 | iz-CORE_BOT_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
123 | PERIMETER_BOT_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
124 | PERIMETER_BOT_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
125 | PERIMETER_BOT_ZN_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
126 | PERIMETER_BOT_ZN_4_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 3 | No | No |
127 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 2 | No | No |
128 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 2 | No | No |
129 | PERIMETER_BOT_ZN_4_WALL_WEST_DOOR | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
130 | PERIMETER_BOT_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
131 | iz-PERIMETER_BOT_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
132 | iz-CORE_BOT_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
133 | PERIMETER_BOT_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
134 | PERIMETER_BOT_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
135 | PERIMETER_BOT_ZN_4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
136 | PERIMETER_MID_ZN_3_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 3 | No | No |
137 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
138 | PERIMETER_MID_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
139 | iz-PERIMETER_MID_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
140 | iz-CORE_MID_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
141 | PERIMETER_MID_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
142 | PERIMETER_MID_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
143 | PERIMETER_MID_ZN_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
144 | PERIMETER_MID_ZN_2_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 3 | No | No |
145 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 2 | No | No |
146 | PERIMETER_MID_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
147 | iz-PERIMETER_MID_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
148 | iz-CORE_MID_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
149 | PERIMETER_MID_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
150 | PERIMETER_MID_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
151 | PERIMETER_MID_ZN_2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
152 | PERIMETER_MID_ZN_1_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 3 | No | No |
153 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
154 | PERIMETER_MID_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
155 | iz-PERIMETER_MID_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
156 | iz-CORE_MID_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
157 | PERIMETER_MID_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
158 | PERIMETER_MID_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
159 | PERIMETER_MID_ZN_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
160 | PERIMETER_MID_ZN_4_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 3 | No | No |
161 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 2 | No | No |
162 | PERIMETER_MID_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
163 | iz-PERIMETER_MID_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
164 | iz-CORE_MID_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
165 | PERIMETER_MID_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
166 | PERIMETER_MID_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
167 | PERIMETER_MID_ZN_4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | PERIMETER_TOP_ZN_3_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 7.798E-002 | 3.761E-004 | 5.696E-004 | 0.494 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | PERIMETER_TOP_ZN_2_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 5.199E-002 | 3.961E-004 | 5.696E-004 | 0.520 | 0.000 | 0.000 | 0.224 | 0.000 |
3 | PERIMETER_TOP_ZN_1_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 7.798E-002 | 3.761E-004 | 5.696E-004 | 0.494 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | PERIMETER_TOP_ZN_4_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 5.199E-002 | 3.961E-004 | 5.696E-004 | 0.520 | 0.000 | 0.000 | 0.224 | 0.000 |
5 | PERIMETER_BOT_ZN_3_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 7.798E-002 | 3.761E-004 | 5.538E-004 | 0.494 | 0.000 | 0.000 | 0.224 | 0.000 |
6 | PERIMETER_BOT_ZN_2_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 5.199E-002 | 3.961E-004 | 5.577E-004 | 0.520 | 0.000 | 0.000 | 0.224 | 0.000 |
7 | PERIMETER_BOT_ZN_1_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 7.798E-002 | 3.761E-004 | 5.538E-004 | 0.494 | 0.000 | 0.000 | 0.224 | 0.000 |
8 | PERIMETER_BOT_ZN_1_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 1.043 | 5.030E-003 | 7.407E-003 | 6.602 | 1.000 | 0.000 | 0.000 | 0.000 |
9 | PERIMETER_BOT_ZN_4_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 5.199E-002 | 3.961E-004 | 5.577E-004 | 0.520 | 0.000 | 0.000 | 0.224 | 0.000 |
10 | PERIMETER_MID_ZN_3_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 7.798E-002 | 3.761E-004 | 5.696E-004 | 0.494 | 0.000 | 0.000 | 0.224 | 0.000 |
11 | PERIMETER_MID_ZN_2_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 5.199E-002 | 3.961E-004 | 5.696E-004 | 0.520 | 0.000 | 0.000 | 0.224 | 0.000 |
12 | PERIMETER_MID_ZN_1_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 7.798E-002 | 3.761E-004 | 5.696E-004 | 0.494 | 0.000 | 0.000 | 0.224 | 0.000 |
13 | PERIMETER_MID_ZN_4_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 5.199E-002 | 3.961E-004 | 5.696E-004 | 0.520 | 0.000 | 0.000 | 0.224 | 0.000 |
14 | FIRSTFLOOR_PLENUM_INFILTRATION | INFIL_SCH_PNNL | FIRSTFLOOR_PLENUM | 1660.73 | 0.0 | 0.116 | 6.957E-005 | 5.696E-004 | 0.205 | 0.000 | 0.000 | 0.224 | 0.000 |
15 | MIDFLOOR_PLENUM_INFILTRATION | INFIL_SCH_PNNL | MIDFLOOR_PLENUM | 1660.73 | 0.0 | 0.116 | 6.957E-005 | 5.696E-004 | 0.205 | 0.000 | 0.000 | 0.224 | 0.000 |
16 | TOPFLOOR_PLENUM_INFILTRATION | INFIL_SCH_PNNL | TOPFLOOR_PLENUM | 1660.73 | 0.0 | 0.116 | 6.957E-005 | 6.199E-005 | 0.205 | 0.000 | 0.000 | 0.224 | 0.000 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | CORE_BOTTOM | Mixing/Well-Stirred |
2 | TOPFLOOR_PLENUM | Mixing/Well-Stirred |
3 | MIDFLOOR_PLENUM | Mixing/Well-Stirred |
4 | FIRSTFLOOR_PLENUM | Mixing/Well-Stirred |
5 | CORE_MID | Mixing/Well-Stirred |
6 | CORE_TOP | Mixing/Well-Stirred |
7 | PERIMETER_TOP_ZN_3 | Mixing/Well-Stirred |
8 | PERIMETER_TOP_ZN_2 | Mixing/Well-Stirred |
9 | PERIMETER_TOP_ZN_1 | Mixing/Well-Stirred |
10 | PERIMETER_TOP_ZN_4 | Mixing/Well-Stirred |
11 | PERIMETER_BOT_ZN_3 | Mixing/Well-Stirred |
12 | PERIMETER_BOT_ZN_2 | Mixing/Well-Stirred |
13 | PERIMETER_BOT_ZN_1 | Mixing/Well-Stirred |
14 | PERIMETER_BOT_ZN_4 | Mixing/Well-Stirred |
15 | PERIMETER_MID_ZN_3 | Mixing/Well-Stirred |
16 | PERIMETER_MID_ZN_2 | Mixing/Well-Stirred |
17 | PERIMETER_MID_ZN_1 | Mixing/Well-Stirred |
18 | PERIMETER_MID_ZN_4 | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.0000 |
Sizing Factor ID | Value | |
1 | Global | 1.0000 |
Sky Type | MonthAndDay | Daylighting Control Name | Enclosure Name | Window Name | Reference Point | Daylight Factor | |
1 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 5.4103E-003 |
2 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 5.4450E-003 |
3 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 5.7203E-003 |
4 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 5.7491E-003 |
5 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 4.3302E-003 |
6 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 4.3526E-003 |
7 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 2.4264E-003 |
8 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 2.4410E-003 |
9 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 8.0405E-002 |
10 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 3.4752E-002 |
11 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 8.8674E-002 |
12 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 3.6731E-002 |
13 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 6.4840E-002 |
14 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 2.5089E-002 |
15 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 2.8057E-002 |
16 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 1.0496E-002 |
17 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 5.4118E-003 |
18 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 5.4541E-003 |
19 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 5.7220E-003 |
20 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 5.7590E-003 |
21 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 4.3319E-003 |
22 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 4.3603E-003 |
23 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 2.4263E-003 |
24 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 2.4409E-003 |
25 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 4.1601E-002 |
26 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 2.3613E-002 |
27 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 3.9380E-002 |
28 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 2.1750E-002 |
29 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 4.0736E-002 |
30 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 2.0066E-002 |
31 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 3.2668E-002 |
32 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 1.5265E-002 |
33 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 3.7049E-004 |
34 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 3.7183E-004 |
35 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 3.5206E-004 |
36 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 3.5303E-004 |
37 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 3.3513E-004 |
38 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 3.3549E-004 |
39 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 2.8320E-004 |
40 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 2.8371E-004 |
41 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.3786E-003 |
42 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.4109E-003 |
43 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.0156E-003 |
44 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.0415E-003 |
45 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 1.7625E-003 |
46 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.7811E-003 |
47 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.4263E-003 |
48 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.4409E-003 |
49 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.1787E-002 |
50 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.2582E-002 |
51 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 1.7031E-002 |
52 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 9.6940E-003 |
53 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 1.6069E-002 |
54 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 6.8272E-003 |
55 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.8057E-002 |
56 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.0496E-002 |
57 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.3781E-003 |
58 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.4103E-003 |
59 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.0148E-003 |
60 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.0396E-003 |
61 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 1.7610E-003 |
62 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.7758E-003 |
63 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.4264E-003 |
64 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.4410E-003 |
65 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 3.3082E-002 |
66 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 1.9776E-002 |
67 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 2.9172E-002 |
68 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 1.7152E-002 |
69 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 3.2366E-002 |
70 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 1.6323E-002 |
71 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 3.2668E-002 |
72 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 1.5265E-002 |
73 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 3.1725E-004 |
74 | Clear Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 3.1996E-004 |
75 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 2.8768E-004 |
76 | Clear Turbid Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 2.9037E-004 |
77 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 2.8527E-004 |
78 | Intermediate Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 2.8675E-004 |
79 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 2.8321E-004 |
80 | Overcast Sky | 01/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 2.8372E-004 |
81 | Clear Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 8.2951E-002 |
82 | Clear Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 4.3028E-002 |
83 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 9.0561E-002 |
84 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 4.5475E-002 |
85 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 6.8990E-002 |
86 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 3.1971E-002 |
87 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 3.1564E-002 |
88 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 1.4627E-002 |
89 | Clear Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 4.0072E-002 |
90 | Clear Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 2.2750E-002 |
91 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 3.8013E-002 |
92 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 2.0978E-002 |
93 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 3.9579E-002 |
94 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 1.9431E-002 |
95 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 3.1886E-002 |
96 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 1.4843E-002 |
97 | Clear Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 2.4885E-002 |
98 | Clear Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 1.6482E-002 |
99 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 1.9832E-002 |
100 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 1.3100E-002 |
101 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 1.8831E-002 |
102 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 9.9664E-003 |
103 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 3.1564E-002 |
104 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 1.4627E-002 |
105 | Clear Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 3.1850E-002 |
106 | Clear Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 1.9101E-002 |
107 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 2.8160E-002 |
108 | Clear Turbid Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 1.6608E-002 |
109 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 3.1492E-002 |
110 | Intermediate Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 1.5863E-002 |
111 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 3.1887E-002 |
112 | Overcast Sky | 01/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 1.4843E-002 |
113 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 8.2950E-002 |
114 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 4.3024E-002 |
115 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 9.0558E-002 |
116 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 4.5471E-002 |
117 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 6.8986E-002 |
118 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 3.1967E-002 |
119 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 3.1562E-002 |
120 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 1.4625E-002 |
121 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 4.0072E-002 |
122 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 2.2749E-002 |
123 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 3.8013E-002 |
124 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 2.0977E-002 |
125 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 3.9577E-002 |
126 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 1.9429E-002 |
127 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 3.1884E-002 |
128 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 1.4841E-002 |
129 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 2.4886E-002 |
130 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 1.6481E-002 |
131 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 1.9832E-002 |
132 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 1.3099E-002 |
133 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 1.8830E-002 |
134 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 9.9656E-003 |
135 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 3.1562E-002 |
136 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 1.4625E-002 |
137 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 3.1850E-002 |
138 | Clear Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 1.9100E-002 |
139 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 2.8160E-002 |
140 | Clear Turbid Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 1.6607E-002 |
141 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 3.1490E-002 |
142 | Intermediate Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 1.5861E-002 |
143 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 3.1884E-002 |
144 | Overcast Sky | 01/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 1.4842E-002 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | CORE_BOTTOM | Cooling | 39716.37102 | 39716.37102 | 2.93597 | 2.93597 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:00:00 | 34.82200 | 9.14597E-003 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
2 | CORE_BOTTOM | Heating | 2822.81295 | 2822.81295 | 0.12283 | 0.42469 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6.30000 | 6.07234E-003 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
3 | CORE_MID | Cooling | 29911.20980 | 29911.20980 | 2.20876 | 2.20876 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:00:00 | 34.82200 | 9.14597E-003 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
4 | CORE_MID | Heating | 8932.77621 | 8932.77621 | 0.38590 | 0.42469 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6.30000 | 6.07234E-003 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
5 | CORE_TOP | Cooling | 33653.27618 | 33653.27618 | 2.50840 | 2.50840 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:20:00 | 41.80600 | 9.15758E-003 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
6 | CORE_TOP | Heating | 17989.29505 | 17989.29505 | 0.78238 | 0.78238 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6.30000 | 6.07234E-003 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
7 | PERIMETER_TOP_ZN_3 | Cooling | 12264.36223 | 12264.36223 | 0.91413 | 0.91413 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:30:00 | 41.70900 | 9.15741E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
8 | PERIMETER_TOP_ZN_3 | Heating | 7383.82538 | 7383.82538 | 0.32246 | 0.32246 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6.30000 | 6.07234E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
9 | PERIMETER_TOP_ZN_2 | Cooling | 9271.15636 | 9271.15636 | 0.69103 | 0.69103 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 10:50:00 | 39.52650 | 9.15377E-003 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
10 | PERIMETER_TOP_ZN_2 | Heating | 4821.08647 | 4821.08647 | 0.21057 | 0.21057 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6.30000 | 6.07234E-003 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
11 | PERIMETER_TOP_ZN_1 | Cooling | 12466.07402 | 12466.07402 | 0.92917 | 0.92917 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 14:40:00 | 42.00000 | 9.15790E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
12 | PERIMETER_TOP_ZN_1 | Heating | 7378.73507 | 7378.73507 | 0.32224 | 0.32224 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6.30000 | 6.07234E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
13 | PERIMETER_TOP_ZN_4 | Cooling | 10320.05099 | 10320.05099 | 0.76921 | 0.76921 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 16:20:00 | 41.15933 | 9.15650E-003 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
14 | PERIMETER_TOP_ZN_4 | Heating | 4827.11530 | 4827.11530 | 0.21083 | 0.21083 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6.30000 | 6.07234E-003 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
15 | PERIMETER_BOT_ZN_3 | Cooling | 9930.24055 | 9930.24055 | 0.74016 | 0.74016 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:20:00 | 41.80600 | 9.15758E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
16 | PERIMETER_BOT_ZN_3 | Heating | 4448.98883 | 4448.98883 | 0.19379 | 0.19379 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6.30000 | 6.07234E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
17 | PERIMETER_BOT_ZN_2 | Cooling | 8002.63275 | 8002.63275 | 0.59648 | 0.59648 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 10:50:00 | 39.52650 | 9.15377E-003 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
18 | PERIMETER_BOT_ZN_2 | Heating | 2945.33202 | 2945.33202 | 0.12834 | 0.12834 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6.30000 | 6.07234E-003 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
19 | PERIMETER_BOT_ZN_1 | Cooling | 10111.10565 | 10111.10565 | 0.75364 | 0.75364 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 14:10:00 | 42.00000 | 9.15790E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
20 | PERIMETER_BOT_ZN_1 | Heating | 4448.98659 | 4448.98659 | 0.19379 | 0.19379 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6.30000 | 6.07234E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
21 | PERIMETER_BOT_ZN_4 | Cooling | 8327.68491 | 8327.68491 | 0.62071 | 0.62071 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 16:30:00 | 41.03000 | 9.15628E-003 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
22 | PERIMETER_BOT_ZN_4 | Heating | 2952.88251 | 2952.88251 | 0.12867 | 0.12867 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6.30000 | 6.07234E-003 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
23 | PERIMETER_MID_ZN_3 | Cooling | 10286.22252 | 10286.22252 | 0.76669 | 0.76669 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:30:00 | 41.70900 | 9.15741E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
24 | PERIMETER_MID_ZN_3 | Heating | 5241.83895 | 5241.83895 | 0.22858 | 0.22858 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6.30000 | 6.07234E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
25 | PERIMETER_MID_ZN_2 | Cooling | 8445.63749 | 8445.63749 | 0.62950 | 0.62950 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 10:30:00 | 39.04150 | 9.15295E-003 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
26 | PERIMETER_MID_ZN_2 | Heating | 3452.69845 | 3452.69845 | 0.15059 | 0.15059 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6.30000 | 6.07234E-003 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
27 | PERIMETER_MID_ZN_1 | Cooling | 10497.12868 | 10497.12868 | 0.78241 | 0.78241 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 14:20:00 | 42.00000 | 9.15790E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
28 | PERIMETER_MID_ZN_1 | Heating | 5235.78136 | 5235.78136 | 0.22831 | 0.22831 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6.30000 | 6.07234E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
29 | PERIMETER_MID_ZN_4 | Cooling | 8923.88524 | 8923.88524 | 0.66515 | 0.66515 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 16:20:00 | 41.15933 | 9.15650E-003 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
30 | PERIMETER_MID_ZN_4 | Heating | 3459.39551 | 3459.39551 | 0.15089 | 0.15089 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6.30000 | 6.07234E-003 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PACU_VAV_BOT | Cooling | Sensible | 95446.08 | 5.30763 | 5.30763 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 00:00:00 |
2 | PACU_VAV_BOT | Heating | Sensible | 8197.86 | 1.06929 | 1.06929 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
3 | PACU_VAV_MID | Cooling | Sensible | 87000.90 | 4.67575 | 4.67575 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 00:00:00 |
4 | PACU_VAV_MID | Heating | Sensible | 9070.12 | 1.18306 | 1.18306 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
5 | PACU_VAV_TOP | Cooling | Sensible | 100521.20 | 5.70975 | 5.70975 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 00:00:00 |
6 | PACU_VAV_TOP | Heating | Sensible | 9152.97 | 1.84848 | 1.84848 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 18:10:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 2.93597 |
2 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.25527 |
3 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.27000 |
4 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.79271 |
5 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.68071 |
6 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
7 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.49256E-003 |
8 | Coil:Heating:Electric | CORE_BOTTOM VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 25807.73805 |
9 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 2.20876 |
10 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.33931 |
11 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.34700 |
12 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.76644 |
13 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.90483 |
14 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
15 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.12287E-003 |
16 | Coil:Heating:Electric | CORE_MID VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 24952.43434 |
17 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 2.50840 |
18 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.29878 |
19 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.32200 |
20 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.80770 |
21 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.79674 |
22 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
23 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.27519E-003 |
24 | Coil:Heating:Electric | CORE_TOP VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 26295.83671 |
25 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.91413 |
26 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.17283 |
27 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
28 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.18283 |
29 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.46089 |
30 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
31 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.20445E-003 |
32 | Coil:Heating:Electric | PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 10498.12557 |
33 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.69103 |
34 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.14474 |
35 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
36 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.13821 |
37 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.38598 |
38 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
39 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.63225E-003 |
40 | Coil:Heating:Electric | PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 6855.35769 |
41 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.92917 |
42 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.17004 |
43 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
44 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.18583 |
45 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.45343 |
46 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
47 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.24070E-003 |
48 | Coil:Heating:Electric | PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 10490.85785 |
49 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.76921 |
50 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.13002 |
51 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
52 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.15384 |
53 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.34673 |
54 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
55 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.93024E-003 |
56 | Coil:Heating:Electric | PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 6863.97010 |
57 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.74016 |
58 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.21346 |
59 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.22600 |
60 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.16728 |
61 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.56922 |
62 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
63 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.78490E-003 |
64 | Coil:Heating:Electric | PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 6309.13950 |
65 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.59648 |
66 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.16769 |
67 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
68 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.11930 |
69 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.44716 |
70 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
71 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.27209E-003 |
72 | Coil:Heating:Electric | PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 4178.26628 |
73 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.75364 |
74 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.20964 |
75 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.22200 |
76 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.16731 |
77 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.55904 |
78 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
79 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.81741E-003 |
80 | Coil:Heating:Electric | PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 6309.13630 |
81 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.62071 |
82 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.16113 |
83 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
84 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.12414 |
85 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.42968 |
86 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
87 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.36454E-003 |
88 | Coil:Heating:Electric | PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 4189.06171 |
89 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.76669 |
90 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.20607 |
91 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.21100 |
92 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.16177 |
93 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.54952 |
94 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
95 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.84889E-003 |
96 | Coil:Heating:Electric | PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 7441.58991 |
97 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.62950 |
98 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.15889 |
99 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
100 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.12590 |
101 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.42371 |
102 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
103 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.39787E-003 |
104 | Coil:Heating:Electric | PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 4902.76408 |
105 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.78241 |
106 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.20193 |
107 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20700 |
108 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.16196 |
109 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.53848 |
110 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
111 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.88680E-003 |
112 | Coil:Heating:Electric | PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 7432.93828 |
113 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.66515 |
114 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.15037 |
115 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
116 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.13303 |
117 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.40098 |
118 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
119 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.53382E-003 |
120 | Coil:Heating:Electric | PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 4912.33148 |
121 | AirLoopHVAC | PACU_VAV_BOT | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.82348 |
122 | AirLoopHVAC | PACU_VAV_BOT | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.37073 |
123 | AirLoopHVAC | PACU_VAV_BOT | Sum of Air Terminal Maximum Flow Rates [m3/s] | 5.64695 |
124 | AirLoopHVAC | PACU_VAV_BOT | Adjusted Heating Design Air Flow Rate [m3/s] | 1.37073 |
125 | AirLoopHVAC | PACU_VAV_BOT | Adjusted Cooling Design Air Flow Rate [m3/s] | 5.30763 |
126 | AirLoopHVAC | PACU_VAV_BOT | Adjusted Main Design Air Flow Rate [m3/s] | 5.30763 |
127 | AirLoopHVAC | PACU_VAV_BOT | User Heating Air Flow Ratio [] | 0.30000 |
128 | AirLoopHVAC | PACU_VAV_BOT | Calculated Heating Air Flow Ratio [] | 0.25826 |
129 | AirLoopHVAC | PACU_VAV_MID | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.52625 |
130 | AirLoopHVAC | PACU_VAV_MID | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.34910 |
131 | AirLoopHVAC | PACU_VAV_MID | Sum of Air Terminal Maximum Flow Rates [m3/s] | 5.05251 |
132 | AirLoopHVAC | PACU_VAV_MID | Adjusted Heating Design Air Flow Rate [m3/s] | 1.34910 |
133 | AirLoopHVAC | PACU_VAV_MID | Adjusted Cooling Design Air Flow Rate [m3/s] | 4.67575 |
134 | AirLoopHVAC | PACU_VAV_MID | Adjusted Main Design Air Flow Rate [m3/s] | 4.67575 |
135 | AirLoopHVAC | PACU_VAV_MID | User Heating Air Flow Ratio [] | 0.30000 |
136 | AirLoopHVAC | PACU_VAV_MID | Calculated Heating Air Flow Ratio [] | 0.28853 |
137 | AirLoopHVAC | PACU_VAV_TOP | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.90597 |
138 | AirLoopHVAC | PACU_VAV_TOP | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.46841 |
139 | AirLoopHVAC | PACU_VAV_TOP | Sum of Air Terminal Maximum Flow Rates [m3/s] | 5.81193 |
140 | AirLoopHVAC | PACU_VAV_TOP | Adjusted Heating Design Air Flow Rate [m3/s] | 1.84848 |
141 | AirLoopHVAC | PACU_VAV_TOP | Adjusted Cooling Design Air Flow Rate [m3/s] | 5.70975 |
142 | AirLoopHVAC | PACU_VAV_TOP | Adjusted Main Design Air Flow Rate [m3/s] | 5.70975 |
143 | AirLoopHVAC | PACU_VAV_TOP | User Heating Air Flow Ratio [] | 0.30000 |
144 | AirLoopHVAC | PACU_VAV_TOP | Calculated Heating Air Flow Ratio [] | 0.32374 |
145 | AirLoopHVAC | PACU_VAV_BOT | Design Supply Air Flow Rate [m3/s] | 5.30763 |
146 | AirLoopHVAC | PACU_VAV_MID | Design Supply Air Flow Rate [m3/s] | 4.67575 |
147 | AirLoopHVAC | PACU_VAV_TOP | Design Supply Air Flow Rate [m3/s] | 5.70975 |
148 | Controller:OutdoorAir | PACU_VAV_BOT_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 5.30763 |
149 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size High Speed Rated Air Flow Rate [m3/s] | 5.30763 |
150 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size High Speed Gross Rated Total Cooling Capacity [W] | 119051.26165 |
151 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size High Speed Rated Sensible Heat Ratio | 0.73433 |
152 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size Low Speed Rated Air Flow Rate [m3/s] | 1.76903 |
153 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size Low Speed Gross Rated Total Cooling Capacity [W] | 39679.78551 |
154 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size Low Speed Gross Rated Sensible Heat Ratio | 0.73433 |
155 | Coil:Heating:Fuel | PACU_VAV_BOT HEATING COIL | Design Size Nominal Capacity [W] | 5376.55848 |
156 | Fan:VariableVolume | PACU_VAV_BOT FAN | Design Size Maximum Flow Rate [m3/s] | 5.30763 |
157 | Controller:OutdoorAir | PACU_VAV_MID_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 4.67575 |
158 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size High Speed Rated Air Flow Rate [m3/s] | 4.67575 |
159 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size High Speed Gross Rated Total Cooling Capacity [W] | 107988.03304 |
160 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size High Speed Rated Sensible Heat Ratio | 0.72452 |
161 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size Low Speed Rated Air Flow Rate [m3/s] | 1.55843 |
162 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size Low Speed Gross Rated Total Cooling Capacity [W] | 35992.41141 |
163 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size Low Speed Gross Rated Sensible Heat Ratio | 0.72452 |
164 | Coil:Heating:Fuel | PACU_VAV_MID HEATING COIL | Design Size Nominal Capacity [W] | 7180.06918 |
165 | Fan:VariableVolume | PACU_VAV_MID FAN | Design Size Maximum Flow Rate [m3/s] | 4.67575 |
166 | Controller:OutdoorAir | PACU_VAV_TOP_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 5.70975 |
167 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size High Speed Rated Air Flow Rate [m3/s] | 5.70975 |
168 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size High Speed Gross Rated Total Cooling Capacity [W] | 126246.03436 |
169 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size High Speed Rated Sensible Heat Ratio | 0.73925 |
170 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size Low Speed Rated Air Flow Rate [m3/s] | 1.90306 |
171 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size Low Speed Gross Rated Total Cooling Capacity [W] | 42077.80325 |
172 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size Low Speed Gross Rated Sensible Heat Ratio | 0.73925 |
173 | Coil:Heating:Fuel | PACU_VAV_TOP HEATING COIL | Design Size Nominal Capacity [W] | 4155.38642 |
174 | Fan:VariableVolume | PACU_VAV_TOP FAN | Design Size Maximum Flow Rate [m3/s] | 5.70975 |
175 | PlantLoop | SWHSYS1 | Maximum Loop Flow Rate [m3/s] | 5.36267E-005 |
176 | PlantLoop | SWHSYS1 | Plant Loop Volume [m3] | 6.43520E-003 |
177 | Pump:ConstantSpeed | SWHSYS1 PUMP | Design Flow Rate [m3/s] | 5.36267E-005 |
178 | Pump:ConstantSpeed | SWHSYS1 PUMP | Design Power Consumption [W] | 0.72612 |
179 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | Use Side Design Flow Rate [m3/s] | 5.36267E-005 |
DX Coil Type | DX Coil Name | Fan Type | Fan Name | Standard Net Cooling Capacity {W} | Standard Net Cooling Capacity {Btu/h} | IEER {Btu/W-h} | COP 100% Capacity {W/W} | COP 75% Capacity {W/W} | COP 50% Capacity {W/W} | COP 25% Capacity {W/W} | EER 100% Capacity {Btu/W-h} | EER 75% Capacity {Btu/W-h} | EER 50% Capacity {Btu/W-h} | EER 25% Capacity {Btu/W-h} | Supply Air Flow 100% {kg/s} | Supply Air Flow 75% {kg/s} | Supply Air Flow 50% {kg/s} | Supply Air Flow 25% {kg/s} | |
1 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | N/A | N/A | 118459.78 | 404201.55 | 11.49 | 2.93 | 3.29 | 3.47 | 3.61 | 10.01 | 11.24 | 11.85 | 12.33 | 5.9840 | 4.7661 | 3.2083 | 1.3370 |
2 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | N/A | N/A | 107558.74 | 367005.65 | 11.55 | 2.94 | 3.31 | 3.49 | 3.63 | 10.05 | 11.30 | 11.91 | 12.37 | 5.2716 | 4.1945 | 2.8235 | 1.1877 |
3 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | N/A | N/A | 125555.90 | 428414.50 | 11.47 | 2.93 | 3.28 | 3.46 | 3.61 | 9.99 | 11.21 | 11.81 | 12.31 | 6.4373 | 5.1294 | 3.4532 | 1.4318 |
Zone Name | # Surfaces | |
1 | CORE_BOTTOM | 7 |
2 | TOPFLOOR_PLENUM | 10 |
3 | MIDFLOOR_PLENUM | 14 |
4 | FIRSTFLOOR_PLENUM | 14 |
5 | CORE_MID | 7 |
6 | CORE_TOP | 7 |
7 | PERIMETER_TOP_ZN_3 | 8 |
8 | PERIMETER_TOP_ZN_2 | 8 |
9 | PERIMETER_TOP_ZN_1 | 8 |
10 | PERIMETER_TOP_ZN_4 | 8 |
11 | PERIMETER_BOT_ZN_3 | 12 |
12 | PERIMETER_BOT_ZN_2 | 10 |
13 | PERIMETER_BOT_ZN_1 | 12 |
14 | PERIMETER_BOT_ZN_4 | 10 |
15 | PERIMETER_MID_ZN_3 | 8 |
16 | PERIMETER_MID_ZN_2 | 8 |
17 | PERIMETER_MID_ZN_1 | 8 |
18 | PERIMETER_MID_ZN_4 | 8 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | CORE_BOT_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_BOT_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | CORE_BOT_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_BOT_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
3 | CORE_BOT_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_BOT_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
4 | CORE_BOT_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_BOT_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
5 | CORE_BOT_ZN_5_FLOOR | Floor | CTF - ConductionTransferFunction | CORE_BOT_ZN_5_FLOOR_FFACTOR | 5.650E-003 | 5.642E-003 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | CORE_BOT_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
6 | CORE_BOT_ZN_5_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 983.54 | 983.54 | 983.54 | 180.00 | 0.00 | 40.76 | 24.13 | 0.00 | iz-CORE_BOT_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
7 | CORE_BOTTOM_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 1967.08 | 1967.08 | 1967.08 | 0.00 | 90.00 | 1967.08 | 1.00 | 0.00 | CORE_BOTTOM_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
8 | PERIMETER_TOP_PLENUM_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.375 | 1.140 | 60.85 | 60.85 | 60.85 | 0.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
9 | PERIMETER_TOP_PLENUM_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.375 | 1.140 | 40.57 | 40.57 | 40.57 | 90.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
10 | PERIMETER_TOP_PLENUM_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.375 | 1.140 | 60.85 | 60.85 | 60.85 | 180.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
11 | PERIMETER_TOP_PLENUM_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.375 | 1.140 | 40.57 | 40.57 | 40.57 | 270.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
12 | iz-PERIMETER_TOP_ZN_1_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 225.00 | 180.00 | 6.47 | 40.76 | 0.00 | PERIMETER_TOP_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
13 | iz-PERIMETER_TOP_ZN_2_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.26 | 131.26 | 131.26 | 135.00 | 180.00 | 6.47 | 24.13 | 0.00 | PERIMETER_TOP_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
14 | iz-PERIMETER_TOP_ZN_3_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 45.00 | 180.00 | 6.47 | 40.76 | 0.00 | PERIMETER_TOP_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
15 | iz-PERIMETER_TOP_ZN_4_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.25 | 131.25 | 131.25 | 315.00 | 180.00 | 6.47 | 24.13 | 0.00 | PERIMETER_TOP_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
16 | iz-CORE_TOP_ZN_5_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 983.54 | 983.54 | 983.54 | 180.00 | 180.00 | 40.76 | 24.13 | 0.00 | CORE_TOP_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
17 | BUILDING_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 1660.73 | 1660.73 | 1660.73 | 0.00 | 0.00 | 49.91 | 33.27 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
18 | PERIMETER_MID_PLENUM_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.013 | 0.880 | 60.85 | 60.85 | 60.85 | 0.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
19 | PERIMETER_MID_PLENUM_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.013 | 0.880 | 40.57 | 40.57 | 40.57 | 90.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
20 | PERIMETER_MID_PLENUM_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.013 | 0.880 | 60.85 | 60.85 | 60.85 | 180.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
21 | PERIMETER_MID_PLENUM_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.013 | 0.880 | 40.57 | 40.57 | 40.57 | 270.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
22 | iz-PERIMETER_MID_ZN_1_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | PERIMETER_MID_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
23 | iz-PERIMETER_MID_ZN_2_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | PERIMETER_MID_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
24 | iz-PERIMETER_MID_ZN_3_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | PERIMETER_MID_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
25 | iz-PERIMETER_MID_ZN_4_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | PERIMETER_MID_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
26 | iz-CORE_MID_ZN_5_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | CORE_MID_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
27 | iz-PERIMETER_TOP_ZN_1_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 207.34 | 207.34 | 207.34 | 0.00 | 0.00 | 40.76 | 6.47 | 0.00 | PERIMETER_TOP_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
28 | iz-PERIMETER_TOP_ZN_2_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 131.26 | 131.26 | 131.26 | 270.00 | 0.00 | 24.13 | 6.47 | 0.00 | PERIMETER_TOP_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
29 | iz-PERIMETER_TOP_ZN_3_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 207.34 | 207.34 | 207.34 | 180.00 | 0.00 | 40.76 | 6.47 | 0.00 | PERIMETER_TOP_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
30 | iz-PERIMETER_TOP_ZN_4_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 131.25 | 131.25 | 131.25 | 90.00 | 0.00 | 24.13 | 6.47 | 0.00 | PERIMETER_TOP_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
31 | iz-CORE_TOP_ZN_5_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 983.54 | 983.54 | 983.54 | 180.00 | 0.00 | 40.76 | 24.13 | 0.00 | CORE_TOP_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
32 | PERIMETER_BOT_PLENUM_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.029 | 0.892 | 60.85 | 60.85 | 60.85 | 0.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
33 | PERIMETER_BOT_PLENUM_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.029 | 0.892 | 40.57 | 40.57 | 40.57 | 90.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
34 | PERIMETER_BOT_PLENUM_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.029 | 0.892 | 60.85 | 60.85 | 60.85 | 180.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
35 | PERIMETER_BOT_PLENUM_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.029 | 0.892 | 40.57 | 40.57 | 40.57 | 270.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
36 | iz-PERIMETER_BOT_ZN_1_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | PERIMETER_BOT_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
37 | iz-PERIMETER_BOT_ZN_2_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | PERIMETER_BOT_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
38 | iz-PERIMETER_BOT_ZN_3_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | PERIMETER_BOT_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
39 | iz-PERIMETER_BOT_ZN_4_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | PERIMETER_BOT_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
40 | iz-CORE_BOT_ZN_5_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | CORE_BOT_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
41 | iz-PERIMETER_MID_ZN_1_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 207.34 | 207.34 | 207.34 | 0.00 | 0.00 | 40.76 | 6.47 | 0.00 | PERIMETER_MID_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
42 | iz-PERIMETER_MID_ZN_2_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 131.26 | 131.26 | 131.26 | 270.00 | 0.00 | 24.13 | 6.47 | 0.00 | PERIMETER_MID_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
43 | iz-PERIMETER_MID_ZN_3_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 207.34 | 207.34 | 207.34 | 180.00 | 0.00 | 40.76 | 6.47 | 0.00 | PERIMETER_MID_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
44 | iz-PERIMETER_MID_ZN_4_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 131.25 | 131.25 | 131.25 | 90.00 | 0.00 | 24.13 | 6.47 | 0.00 | PERIMETER_MID_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
45 | iz-CORE_MID_ZN_5_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 983.54 | 983.54 | 983.54 | 180.00 | 0.00 | 40.76 | 24.13 | 0.00 | CORE_MID_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
46 | CORE_MID_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_MID_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
47 | CORE_MID_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_MID_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
48 | CORE_MID_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_MID_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
49 | CORE_MID_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_MID_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
50 | CORE_MID_ZN_5_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | iz-CORE_MID_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
51 | CORE_MID_ZN_5_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 983.54 | 983.54 | 983.54 | 180.00 | 0.00 | 40.76 | 24.13 | 0.00 | iz-CORE_MID_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
52 | CORE_MID_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 1967.08 | 1967.08 | 1967.08 | 0.00 | 90.00 | 1967.08 | 1.00 | 0.00 | CORE_MID_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
53 | CORE_TOP_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_TOP_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
54 | CORE_TOP_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_TOP_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
55 | CORE_TOP_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_TOP_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
56 | CORE_TOP_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_TOP_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
57 | CORE_TOP_ZN_5_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | iz-CORE_TOP_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
58 | CORE_TOP_ZN_5_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 983.54 | 983.54 | 983.54 | 0.00 | 0.00 | 40.76 | 24.13 | 0.00 | iz-CORE_TOP_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
59 | CORE_TOP_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 1967.08 | 1967.08 | 1967.08 | 0.00 | 90.00 | 1967.08 | 1.00 | 0.00 | CORE_TOP_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
60 | PERIMETER_TOP_ZN_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.375 | 1.140 | 77.59 | 136.92 | 77.59 | 0.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | Window | PERIMETER_TOP_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.5047_SHGC_NORTH_0.25 | N/A | 2.869 | No | 59.33 | 59.33 | 59.33 | 0.00 | 90.00 | 49.91 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
62 | PERIMETER_TOP_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_TOP_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
63 | iz-PERIMETER_TOP_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
64 | iz-CORE_TOP_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
65 | PERIMETER_TOP_ZN_3_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_TOP_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
66 | PERIMETER_TOP_ZN_3_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 225.00 | 0.00 | 6.47 | 49.91 | 0.00 | iz-PERIMETER_TOP_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
67 | PERIMETER_TOP_ZN_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.68 | 414.68 | 414.68 | 0.00 | 90.00 | 414.68 | 1.00 | 0.00 | PERIMETER_TOP_ZN_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
68 | PERIMETER_TOP_ZN_2_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.375 | 1.140 | 51.72 | 91.28 | 51.72 | 90.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
69 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | Window | PERIMETER_TOP_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.5047_SHGC_EAST_0.25 | N/A | 2.869 | No | 39.55 | 39.55 | 39.55 | 90.00 | 90.00 | 33.27 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
70 | PERIMETER_TOP_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_TOP_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
71 | iz-PERIMETER_TOP_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
72 | iz-CORE_TOP_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
73 | PERIMETER_TOP_ZN_2_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_TOP_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
74 | PERIMETER_TOP_ZN_2_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.26 | 131.26 | 131.26 | 315.00 | 0.00 | 6.47 | 33.27 | 0.00 | iz-PERIMETER_TOP_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
75 | PERIMETER_TOP_ZN_2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_TOP_ZN_2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
76 | PERIMETER_TOP_ZN_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.375 | 1.140 | 77.59 | 136.92 | 77.59 | 180.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
77 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | Window | PERIMETER_TOP_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.5047_SHGC_SOUTH_0.25 | N/A | 2.869 | No | 59.33 | 59.33 | 59.33 | 180.00 | 90.00 | 49.91 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
78 | PERIMETER_TOP_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_TOP_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
79 | iz-PERIMETER_TOP_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
80 | iz-CORE_TOP_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
81 | PERIMETER_TOP_ZN_1_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_TOP_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
82 | PERIMETER_TOP_ZN_1_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 45.00 | 0.00 | 6.47 | 49.91 | 0.00 | iz-PERIMETER_TOP_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
83 | PERIMETER_TOP_ZN_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.67 | 414.67 | 414.67 | 0.00 | 90.00 | 414.67 | 1.00 | 0.00 | PERIMETER_TOP_ZN_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
84 | PERIMETER_TOP_ZN_4_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.375 | 1.140 | 51.72 | 91.28 | 51.72 | 270.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
85 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | Window | PERIMETER_TOP_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.5047_SHGC_WEST_0.25 | N/A | 2.869 | No | 39.55 | 39.55 | 39.55 | 270.00 | 90.00 | 33.27 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
86 | PERIMETER_TOP_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_TOP_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
87 | iz-PERIMETER_TOP_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
88 | iz-CORE_TOP_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
89 | PERIMETER_TOP_ZN_4_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_TOP_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
90 | PERIMETER_TOP_ZN_4_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.25 | 131.25 | 131.25 | 135.00 | 0.00 | 6.47 | 33.27 | 0.00 | iz-PERIMETER_TOP_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
91 | PERIMETER_TOP_ZN_4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_TOP_ZN_4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
92 | PERIMETER_BOT_ZN_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.029 | 0.892 | 73.69 | 136.92 | 73.69 | 0.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
93 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | Window | PERIMETER_BOT_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.5047_SHGC_NORTH_0.25 | N/A | 2.869 | No | 19.78 | 19.78 | 19.78 | 0.00 | 90.00 | 15.82 | 1.25 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
94 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | Window | PERIMETER_BOT_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.5047_SHGC_NORTH_0.25 | N/A | 2.869 | No | 19.78 | 19.78 | 19.78 | 0.00 | 90.00 | 15.82 | 1.25 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
95 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | Window | PERIMETER_BOT_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.5047_SHGC_NORTH_0.25 | N/A | 2.869 | No | 19.78 | 19.78 | 19.78 | 0.00 | 90.00 | 15.82 | 1.25 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
96 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | Door | PERIMETER_BOT_ZN_3_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
97 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | Door | PERIMETER_BOT_ZN_3_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
98 | PERIMETER_BOT_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_BOT_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
99 | iz-PERIMETER_BOT_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
100 | iz-CORE_BOT_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
101 | PERIMETER_BOT_ZN_3_FLOOR | Floor | CTF - ConductionTransferFunction | PERIMETER_BOT_ZN_3_FLOOR_FFACTOR | 0.319 | 0.296 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
102 | PERIMETER_BOT_ZN_3_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 180.00 | 0.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_BOT_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
103 | PERIMETER_BOT_ZN_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.68 | 414.68 | 414.68 | 0.00 | 90.00 | 414.68 | 1.00 | 0.00 | PERIMETER_BOT_ZN_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
104 | PERIMETER_BOT_ZN_2_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.029 | 0.892 | 49.77 | 91.28 | 49.77 | 90.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
105 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | Window | PERIMETER_BOT_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.5047_SHGC_EAST_0.25 | N/A | 2.869 | No | 38.05 | 38.05 | 38.05 | 90.00 | 90.00 | 30.84 | 1.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
106 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | Window | PERIMETER_BOT_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.5047_SHGC_EAST_0.25 | N/A | 2.869 | No | 1.50 | 1.50 | 1.50 | 90.00 | 90.00 | 1.22 | 1.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
107 | PERIMETER_BOT_ZN_2_WALL_EAST_DOOR | Door | PERIMETER_BOT_ZN_2_WALL_EAST | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
108 | PERIMETER_BOT_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_BOT_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
109 | iz-PERIMETER_BOT_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
110 | iz-CORE_BOT_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
111 | PERIMETER_BOT_ZN_2_FLOOR | Floor | CTF - ConductionTransferFunction | PERIMETER_BOT_ZN_2_FLOOR_FFACTOR | 0.337 | 0.312 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
112 | PERIMETER_BOT_ZN_2_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.26 | 131.26 | 131.26 | 270.00 | 0.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_BOT_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
113 | PERIMETER_BOT_ZN_2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_BOT_ZN_2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
114 | PERIMETER_BOT_ZN_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.029 | 0.892 | 73.69 | 136.92 | 73.69 | 180.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
115 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | Window | PERIMETER_BOT_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.5047_SHGC_SOUTH_0.25 | N/A | 2.869 | No | 19.78 | 19.78 | 19.78 | 180.00 | 90.00 | 15.82 | 1.25 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
116 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | Window | PERIMETER_BOT_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.5047_SHGC_SOUTH_0.25 | N/A | 2.869 | No | 19.78 | 19.78 | 19.78 | 180.00 | 90.00 | 15.82 | 1.25 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
117 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | Window | PERIMETER_BOT_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.5047_SHGC_SOUTH_0.25 | N/A | 2.869 | No | 19.78 | 19.78 | 19.78 | 180.00 | 90.00 | 15.82 | 1.25 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
118 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | Door | PERIMETER_BOT_ZN_1_WALL_SOUTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 180.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
119 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | Door | PERIMETER_BOT_ZN_1_WALL_SOUTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 180.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
120 | PERIMETER_BOT_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_BOT_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
121 | iz-PERIMETER_BOT_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
122 | iz-CORE_BOT_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
123 | PERIMETER_BOT_ZN_1_FLOOR | Floor | CTF - ConductionTransferFunction | PERIMETER_BOT_ZN_1_FLOOR_FFACTOR | 0.319 | 0.296 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
124 | PERIMETER_BOT_ZN_1_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 0.00 | 0.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_BOT_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
125 | PERIMETER_BOT_ZN_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.67 | 414.67 | 414.67 | 0.00 | 90.00 | 414.67 | 1.00 | 0.00 | PERIMETER_BOT_ZN_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
126 | PERIMETER_BOT_ZN_4_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.029 | 0.892 | 49.77 | 91.28 | 49.77 | 270.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
127 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | Window | PERIMETER_BOT_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.5047_SHGC_WEST_0.25 | N/A | 2.869 | No | 38.05 | 38.05 | 38.05 | 270.00 | 90.00 | 30.84 | 1.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
128 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | Window | PERIMETER_BOT_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.5047_SHGC_WEST_0.25 | N/A | 2.869 | No | 1.50 | 1.50 | 1.50 | 270.00 | 90.00 | 1.22 | 1.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
129 | PERIMETER_BOT_ZN_4_WALL_WEST_DOOR | Door | PERIMETER_BOT_ZN_4_WALL_WEST | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
130 | PERIMETER_BOT_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_BOT_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
131 | iz-PERIMETER_BOT_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
132 | iz-CORE_BOT_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
133 | PERIMETER_BOT_ZN_4_FLOOR | Floor | CTF - ConductionTransferFunction | PERIMETER_BOT_ZN_4_FLOOR_FFACTOR | 0.337 | 0.312 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
134 | PERIMETER_BOT_ZN_4_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.25 | 131.25 | 131.25 | 90.00 | 0.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_BOT_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
135 | PERIMETER_BOT_ZN_4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_BOT_ZN_4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
136 | PERIMETER_MID_ZN_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.013 | 0.880 | 77.59 | 136.92 | 77.59 | 0.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
137 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | Window | PERIMETER_MID_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.5047_SHGC_NORTH_0.25 | N/A | 2.869 | No | 59.33 | 59.33 | 59.33 | 0.00 | 90.00 | 49.91 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
138 | PERIMETER_MID_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_MID_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
139 | iz-PERIMETER_MID_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
140 | iz-CORE_MID_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
141 | PERIMETER_MID_ZN_3_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
142 | PERIMETER_MID_ZN_3_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 180.00 | 0.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
143 | PERIMETER_MID_ZN_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.68 | 414.68 | 414.68 | 0.00 | 90.00 | 414.68 | 1.00 | 0.00 | PERIMETER_MID_ZN_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
144 | PERIMETER_MID_ZN_2_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.013 | 0.880 | 51.72 | 91.28 | 51.72 | 90.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
145 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | Window | PERIMETER_MID_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.5047_SHGC_EAST_0.25 | N/A | 2.869 | No | 39.55 | 39.55 | 39.55 | 90.00 | 90.00 | 33.27 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
146 | PERIMETER_MID_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_MID_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
147 | iz-PERIMETER_MID_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
148 | iz-CORE_MID_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
149 | PERIMETER_MID_ZN_2_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
150 | PERIMETER_MID_ZN_2_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.26 | 131.26 | 131.26 | 270.00 | 0.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
151 | PERIMETER_MID_ZN_2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_MID_ZN_2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
152 | PERIMETER_MID_ZN_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.013 | 0.880 | 77.59 | 136.92 | 77.59 | 180.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
153 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | Window | PERIMETER_MID_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.5047_SHGC_SOUTH_0.25 | N/A | 2.869 | No | 59.33 | 59.33 | 59.33 | 180.00 | 90.00 | 49.91 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
154 | PERIMETER_MID_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_MID_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
155 | iz-PERIMETER_MID_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
156 | iz-CORE_MID_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
157 | PERIMETER_MID_ZN_1_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
158 | PERIMETER_MID_ZN_1_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 0.00 | 0.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
159 | PERIMETER_MID_ZN_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.67 | 414.67 | 414.67 | 0.00 | 90.00 | 414.67 | 1.00 | 0.00 | PERIMETER_MID_ZN_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
160 | PERIMETER_MID_ZN_4_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.013 | 0.880 | 51.72 | 91.28 | 51.72 | 270.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
161 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | Window | PERIMETER_MID_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.5047_SHGC_WEST_0.25 | N/A | 2.869 | No | 39.55 | 39.55 | 39.55 | 270.00 | 90.00 | 33.27 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
162 | PERIMETER_MID_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_MID_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
163 | iz-PERIMETER_MID_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
164 | iz-CORE_MID_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
165 | PERIMETER_MID_ZN_4_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
166 | PERIMETER_MID_ZN_4_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.25 | 131.25 | 131.25 | 90.00 | 0.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
167 | PERIMETER_MID_ZN_4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_MID_ZN_4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes | Clark and Allen |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1Environment:Special Days |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | CORE_BOTTOM | RunPeriod: RUNPERIOD 1 | 4.4364345885E-003 | 2.2043602354E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
2 | TOPFLOOR_PLENUM | RunPeriod: RUNPERIOD 1 | 8.8047034201E-002 | 6.0864548415E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
3 | MIDFLOOR_PLENUM | RunPeriod: RUNPERIOD 1 | 1.2304664075E-002 | 5.4899975717E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
4 | FIRSTFLOOR_PLENUM | RunPeriod: RUNPERIOD 1 | 1.0831562791E-002 | 5.2351185447E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
5 | CORE_MID | RunPeriod: RUNPERIOD 1 | 6.3991967296E-003 | 2.9669418153E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
6 | CORE_TOP | RunPeriod: RUNPERIOD 1 | 2.7154578693E-002 | 1.4392961359E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
7 | PERIMETER_TOP_ZN_3 | RunPeriod: RUNPERIOD 1 | 4.4877316372E-002 | 2.5276361251E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
8 | PERIMETER_TOP_ZN_2 | RunPeriod: RUNPERIOD 1 | 5.1878938545E-002 | 3.2939003122E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
9 | PERIMETER_TOP_ZN_1 | RunPeriod: RUNPERIOD 1 | 8.0312832912E-002 | 5.1905806648E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
10 | PERIMETER_TOP_ZN_4 | RunPeriod: RUNPERIOD 1 | 6.3630969502E-002 | 4.2519262712E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
11 | PERIMETER_BOT_ZN_3 | RunPeriod: RUNPERIOD 1 | 2.4852097005E-002 | 1.6087117497E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
12 | PERIMETER_BOT_ZN_2 | RunPeriod: RUNPERIOD 1 | 3.0625373022E-002 | 2.9664416080E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
13 | PERIMETER_BOT_ZN_1 | RunPeriod: RUNPERIOD 1 | 4.9306632559E-002 | 3.6531893362E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
14 | PERIMETER_BOT_ZN_4 | RunPeriod: RUNPERIOD 1 | 3.6697719496E-002 | 2.9803183214E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
15 | PERIMETER_MID_ZN_3 | RunPeriod: RUNPERIOD 1 | 2.8685717101E-002 | 1.6485984343E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
16 | PERIMETER_MID_ZN_2 | RunPeriod: RUNPERIOD 1 | 3.6489009487E-002 | 3.4342567053E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
17 | PERIMETER_MID_ZN_1 | RunPeriod: RUNPERIOD 1 | 6.2479734787E-002 | 4.3910981170E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
18 | PERIMETER_MID_ZN_4 | RunPeriod: RUNPERIOD 1 | 4.5518167098E-002 | 3.3833672034E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
Report: Annual Heat Emissions Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
Heat Emission by ComponentsEnvelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
Heat Emissions [GJ] | 2538.60 | -55.0 | 0.00 | -683.0 | 3378.49 | 5179.10 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 6.30 | 0.00 | 6.30 | Wetbulb [C] | 0.50 | 270.00 |
NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 42.00 | 9.70 | 22.20 | Wetbulb [C] | 3.20 | 320.00 |
Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
Jan | 0.60 | 4 | |||
Feb | 21.40 | 43 | |||
Mar | 12.00 | 35 | |||
Apr | 29.10 | 12 | |||
May | 29.10 | 57 | |||
Jun | 197.10 | 59 | |||
Jul | 47.90 | 83 | |||
Aug | 0.00 | 0 | |||
Sep | 171.60 | 106 | |||
Oct | 4.80 | 31 | |||
Nov | 1.20 | 7 | |||
Dec | 33.00 | 13 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
PERIMETER_TOP_PLENUM_WALL_NORTH | NONRES_EXT_WALL_TOP | 0.30 | 1.140 | 1.375 | 60.85 | 60.85 | 0.00 | 90.00 | N |
PERIMETER_TOP_PLENUM_WALL_EAST | NONRES_EXT_WALL_TOP | 0.30 | 1.140 | 1.375 | 40.57 | 40.57 | 90.00 | 90.00 | E |
PERIMETER_TOP_PLENUM_WALL_SOUTH | NONRES_EXT_WALL_TOP | 0.30 | 1.140 | 1.375 | 60.85 | 60.85 | 180.00 | 90.00 | S |
PERIMETER_TOP_PLENUM_WALL_WEST | NONRES_EXT_WALL_TOP | 0.30 | 1.140 | 1.375 | 40.57 | 40.57 | 270.00 | 90.00 | W |
BUILDING_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 1660.73 | 1660.73 | 0.00 | 0.00 | |
PERIMETER_MID_PLENUM_WALL_NORTH | NONRES_EXT_WALL_MID | 0.30 | 0.880 | 1.013 | 60.85 | 60.85 | 0.00 | 90.00 | N |
PERIMETER_MID_PLENUM_WALL_EAST | NONRES_EXT_WALL_MID | 0.30 | 0.880 | 1.013 | 40.57 | 40.57 | 90.00 | 90.00 | E |
PERIMETER_MID_PLENUM_WALL_SOUTH | NONRES_EXT_WALL_MID | 0.30 | 0.880 | 1.013 | 60.85 | 60.85 | 180.00 | 90.00 | S |
PERIMETER_MID_PLENUM_WALL_WEST | NONRES_EXT_WALL_MID | 0.30 | 0.880 | 1.013 | 40.57 | 40.57 | 270.00 | 90.00 | W |
PERIMETER_BOT_PLENUM_WALL_NORTH | NONRES_EXT_WALL_GRD | 0.30 | 0.892 | 1.029 | 60.85 | 60.85 | 0.00 | 90.00 | N |
PERIMETER_BOT_PLENUM_WALL_EAST | NONRES_EXT_WALL_GRD | 0.30 | 0.892 | 1.029 | 40.57 | 40.57 | 90.00 | 90.00 | E |
PERIMETER_BOT_PLENUM_WALL_SOUTH | NONRES_EXT_WALL_GRD | 0.30 | 0.892 | 1.029 | 60.85 | 60.85 | 180.00 | 90.00 | S |
PERIMETER_BOT_PLENUM_WALL_WEST | NONRES_EXT_WALL_GRD | 0.30 | 0.892 | 1.029 | 40.57 | 40.57 | 270.00 | 90.00 | W |
PERIMETER_TOP_ZN_3_WALL_NORTH | NONRES_EXT_WALL_TOP | 0.30 | 1.140 | 1.375 | 136.92 | 77.59 | 0.00 | 90.00 | N |
PERIMETER_TOP_ZN_2_WALL_EAST | NONRES_EXT_WALL_TOP | 0.30 | 1.140 | 1.375 | 91.28 | 51.72 | 90.00 | 90.00 | E |
PERIMETER_TOP_ZN_1_WALL_SOUTH | NONRES_EXT_WALL_TOP | 0.30 | 1.140 | 1.375 | 136.92 | 77.59 | 180.00 | 90.00 | S |
PERIMETER_TOP_ZN_4_WALL_WEST | NONRES_EXT_WALL_TOP | 0.30 | 1.140 | 1.375 | 91.28 | 51.72 | 270.00 | 90.00 | W |
PERIMETER_BOT_ZN_3_WALL_NORTH | NONRES_EXT_WALL_GRD | 0.30 | 0.892 | 1.029 | 136.92 | 73.69 | 0.00 | 90.00 | N |
PERIMETER_BOT_ZN_3_FLOOR | PERIMETER_BOT_ZN_3_FLOOR_FFACTOR | 1.00 | 0.304 | 0.319 | 207.34 | 207.34 | 0.00 | 180.00 | |
PERIMETER_BOT_ZN_2_WALL_EAST | NONRES_EXT_WALL_GRD | 0.30 | 0.892 | 1.029 | 91.28 | 49.77 | 90.00 | 90.00 | E |
PERIMETER_BOT_ZN_2_FLOOR | PERIMETER_BOT_ZN_2_FLOOR_FFACTOR | 1.00 | 0.320 | 0.337 | 131.26 | 131.26 | 90.00 | 180.00 | |
PERIMETER_BOT_ZN_1_WALL_SOUTH | NONRES_EXT_WALL_GRD | 0.30 | 0.892 | 1.029 | 136.92 | 73.69 | 180.00 | 90.00 | S |
PERIMETER_BOT_ZN_1_FLOOR | PERIMETER_BOT_ZN_1_FLOOR_FFACTOR | 1.00 | 0.304 | 0.319 | 207.34 | 207.34 | 180.00 | 180.00 | |
PERIMETER_BOT_ZN_4_WALL_WEST | NONRES_EXT_WALL_GRD | 0.30 | 0.892 | 1.029 | 91.28 | 49.77 | 270.00 | 90.00 | W |
PERIMETER_BOT_ZN_4_FLOOR | PERIMETER_BOT_ZN_4_FLOOR_FFACTOR | 1.00 | 0.320 | 0.337 | 131.25 | 131.25 | 270.00 | 180.00 | |
PERIMETER_MID_ZN_3_WALL_NORTH | NONRES_EXT_WALL_MID | 0.30 | 0.880 | 1.013 | 136.92 | 77.59 | 0.00 | 90.00 | N |
PERIMETER_MID_ZN_2_WALL_EAST | NONRES_EXT_WALL_MID | 0.30 | 0.880 | 1.013 | 91.28 | 51.72 | 90.00 | 90.00 | E |
PERIMETER_MID_ZN_1_WALL_SOUTH | NONRES_EXT_WALL_MID | 0.30 | 0.880 | 1.013 | 136.92 | 77.59 | 180.00 | 90.00 | S |
PERIMETER_MID_ZN_4_WALL_WEST | NONRES_EXT_WALL_MID | 0.30 | 0.880 | 1.013 | 91.28 | 51.72 | 270.00 | 90.00 | W |
Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
CORE_BOT_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
CORE_BOT_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
CORE_BOT_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
CORE_BOT_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
CORE_BOT_ZN_5_FLOOR | CORE_BOT_ZN_5_FLOOR_FFACTOR | 1.00 | 0.006 | 0.006 | 983.54 | 983.54 | 0.00 | 180.00 | |
CORE_BOT_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 180.00 | 0.00 | |
iz-PERIMETER_TOP_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 225.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 135.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 45.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 315.00 | 180.00 | |
iz-CORE_TOP_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 180.00 | 180.00 | |
iz-PERIMETER_MID_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 180.00 | 180.00 | |
iz-PERIMETER_MID_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 90.00 | 180.00 | |
iz-PERIMETER_MID_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 0.00 | 180.00 | |
iz-PERIMETER_MID_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 270.00 | 180.00 | |
iz-CORE_MID_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 0.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_1_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 0.00 | 0.00 | |
iz-PERIMETER_TOP_ZN_2_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 131.26 | 131.26 | 270.00 | 0.00 | |
iz-PERIMETER_TOP_ZN_3_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 180.00 | 0.00 | |
iz-PERIMETER_TOP_ZN_4_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 131.25 | 131.25 | 90.00 | 0.00 | |
iz-CORE_TOP_ZN_5_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 983.54 | 983.54 | 180.00 | 0.00 | |
iz-PERIMETER_BOT_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 180.00 | 180.00 | |
iz-PERIMETER_BOT_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 90.00 | 180.00 | |
iz-PERIMETER_BOT_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 0.00 | 180.00 | |
iz-PERIMETER_BOT_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 270.00 | 180.00 | |
iz-CORE_BOT_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 0.00 | 180.00 | |
iz-PERIMETER_MID_ZN_1_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 0.00 | 0.00 | |
iz-PERIMETER_MID_ZN_2_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 131.26 | 131.26 | 270.00 | 0.00 | |
iz-PERIMETER_MID_ZN_3_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 180.00 | 0.00 | |
iz-PERIMETER_MID_ZN_4_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 131.25 | 131.25 | 90.00 | 0.00 | |
iz-CORE_MID_ZN_5_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 983.54 | 983.54 | 180.00 | 0.00 | |
CORE_MID_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
CORE_MID_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
CORE_MID_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
CORE_MID_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
CORE_MID_ZN_5_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 983.54 | 983.54 | 0.00 | 180.00 | |
CORE_MID_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 180.00 | 0.00 | |
CORE_TOP_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
CORE_TOP_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
CORE_TOP_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
CORE_TOP_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
CORE_TOP_ZN_5_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 983.54 | 983.54 | 0.00 | 180.00 | |
CORE_TOP_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 0.00 | 0.00 | |
PERIMETER_TOP_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-PERIMETER_TOP_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-CORE_TOP_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
PERIMETER_TOP_ZN_3_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 0.00 | 180.00 | |
PERIMETER_TOP_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 225.00 | 0.00 | |
PERIMETER_TOP_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-PERIMETER_TOP_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-CORE_TOP_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
PERIMETER_TOP_ZN_2_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 131.26 | 131.26 | 90.00 | 180.00 | |
PERIMETER_TOP_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 315.00 | 0.00 | |
PERIMETER_TOP_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-PERIMETER_TOP_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-CORE_TOP_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
PERIMETER_TOP_ZN_1_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 180.00 | 180.00 | |
PERIMETER_TOP_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 45.00 | 0.00 | |
PERIMETER_TOP_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-PERIMETER_TOP_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-CORE_TOP_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
PERIMETER_TOP_ZN_4_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 131.25 | 131.25 | 270.00 | 180.00 | |
PERIMETER_TOP_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 135.00 | 0.00 | |
PERIMETER_BOT_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-PERIMETER_BOT_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-CORE_BOT_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
PERIMETER_BOT_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 180.00 | 0.00 | |
PERIMETER_BOT_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-PERIMETER_BOT_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-CORE_BOT_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
PERIMETER_BOT_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 270.00 | 0.00 | |
PERIMETER_BOT_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-PERIMETER_BOT_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-CORE_BOT_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
PERIMETER_BOT_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 0.00 | 0.00 | |
PERIMETER_BOT_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-PERIMETER_BOT_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-CORE_BOT_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
PERIMETER_BOT_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 90.00 | 0.00 | |
PERIMETER_MID_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-PERIMETER_MID_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-CORE_MID_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
PERIMETER_MID_ZN_3_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 0.00 | 180.00 | |
PERIMETER_MID_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 180.00 | 0.00 | |
PERIMETER_MID_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-PERIMETER_MID_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-CORE_MID_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
PERIMETER_MID_ZN_2_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 131.26 | 131.26 | 90.00 | 180.00 | |
PERIMETER_MID_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 270.00 | 0.00 | |
PERIMETER_MID_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-PERIMETER_MID_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-CORE_MID_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
PERIMETER_MID_ZN_1_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 180.00 | 180.00 | |
PERIMETER_MID_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 0.00 | 0.00 | |
PERIMETER_MID_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-PERIMETER_MID_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-CORE_MID_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
PERIMETER_MID_ZN_4_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 131.25 | 131.25 | 270.00 | 180.00 | |
PERIMETER_MID_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 90.00 | 0.00 | |
CORE_BOTTOM_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 1967.08 | 0.00 | 90.00 | N | ||
CORE_MID_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 1967.08 | 0.00 | 90.00 | N | ||
CORE_TOP_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 1967.08 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.68 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_2_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.67 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_4_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.68 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_2_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.67 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_4_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.68 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_2_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.67 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_4_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N |
Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | WINDOW_U_0.5047_SHGC_NORTH_0.25 | 59.33 | 0.00 | 0.00 | 59.33 | 59.33 | 2.869 | 0.251 | 0.251 | No | PERIMETER_TOP_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | WINDOW_U_0.5047_SHGC_EAST_0.25 | 39.55 | 0.00 | 0.00 | 39.55 | 39.55 | 2.869 | 0.251 | 0.251 | No | PERIMETER_TOP_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | WINDOW_U_0.5047_SHGC_SOUTH_0.25 | 59.33 | 0.00 | 0.00 | 59.33 | 59.33 | 2.869 | 0.251 | 0.251 | No | PERIMETER_TOP_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | WINDOW_U_0.5047_SHGC_WEST_0.25 | 39.55 | 0.00 | 0.00 | 39.55 | 39.55 | 2.869 | 0.251 | 0.251 | No | PERIMETER_TOP_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | WINDOW_U_0.5047_SHGC_NORTH_0.25 | 19.78 | 0.00 | 0.00 | 19.78 | 19.78 | 2.869 | 0.251 | 0.251 | No | PERIMETER_BOT_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | WINDOW_U_0.5047_SHGC_NORTH_0.25 | 19.78 | 0.00 | 0.00 | 19.78 | 19.78 | 2.869 | 0.251 | 0.251 | No | PERIMETER_BOT_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | WINDOW_U_0.5047_SHGC_NORTH_0.25 | 19.78 | 0.00 | 0.00 | 19.78 | 19.78 | 2.869 | 0.251 | 0.251 | No | PERIMETER_BOT_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | WINDOW_U_0.5047_SHGC_EAST_0.25 | 38.05 | 0.00 | 0.00 | 38.05 | 38.05 | 2.869 | 0.251 | 0.251 | No | PERIMETER_BOT_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | WINDOW_U_0.5047_SHGC_EAST_0.25 | 1.50 | 0.00 | 0.00 | 1.50 | 1.50 | 2.869 | 0.251 | 0.251 | No | PERIMETER_BOT_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | WINDOW_U_0.5047_SHGC_SOUTH_0.25 | 19.78 | 0.00 | 0.00 | 19.78 | 19.78 | 2.869 | 0.251 | 0.251 | No | PERIMETER_BOT_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | WINDOW_U_0.5047_SHGC_SOUTH_0.25 | 19.78 | 0.00 | 0.00 | 19.78 | 19.78 | 2.869 | 0.251 | 0.251 | No | PERIMETER_BOT_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | WINDOW_U_0.5047_SHGC_SOUTH_0.25 | 19.78 | 0.00 | 0.00 | 19.78 | 19.78 | 2.869 | 0.251 | 0.251 | No | PERIMETER_BOT_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | WINDOW_U_0.5047_SHGC_WEST_0.25 | 38.05 | 0.00 | 0.00 | 38.05 | 38.05 | 2.869 | 0.251 | 0.251 | No | PERIMETER_BOT_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | WINDOW_U_0.5047_SHGC_WEST_0.25 | 1.50 | 0.00 | 0.00 | 1.50 | 1.50 | 2.869 | 0.251 | 0.251 | No | PERIMETER_BOT_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | WINDOW_U_0.5047_SHGC_NORTH_0.25 | 59.33 | 0.00 | 0.00 | 59.33 | 59.33 | 2.869 | 0.251 | 0.251 | No | PERIMETER_MID_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | WINDOW_U_0.5047_SHGC_EAST_0.25 | 39.55 | 0.00 | 0.00 | 39.55 | 39.55 | 2.869 | 0.251 | 0.251 | No | PERIMETER_MID_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | WINDOW_U_0.5047_SHGC_SOUTH_0.25 | 59.33 | 0.00 | 0.00 | 59.33 | 59.33 | 2.869 | 0.251 | 0.251 | No | PERIMETER_MID_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | WINDOW_U_0.5047_SHGC_WEST_0.25 | 39.55 | 0.00 | 0.00 | 39.55 | 39.55 | 2.869 | 0.251 | 0.251 | No | PERIMETER_MID_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
Total or Average | 593.29 | 2.869 | 0.251 | 0.251 | |||||||||||||||||
North Total or Average | 177.99 | 2.869 | 0.251 | 0.251 | |||||||||||||||||
Non-North Total or Average | 415.31 | 2.869 | 0.251 | 0.251 |
Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
None |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | PERIMETER_BOT_ZN_3_WALL_NORTH |
PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | PERIMETER_BOT_ZN_3_WALL_NORTH |
PERIMETER_BOT_ZN_2_WALL_EAST_DOOR | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | PERIMETER_BOT_ZN_2_WALL_EAST |
PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | PERIMETER_BOT_ZN_1_WALL_SOUTH |
PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | PERIMETER_BOT_ZN_1_WALL_SOUTH |
PERIMETER_BOT_ZN_4_WALL_WEST_DOOR | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | PERIMETER_BOT_ZN_4_WALL_WEST |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
Interior LightingZone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
CORE_BOTTOM_LIGHTS | CORE_BOTTOM | CORE_BOTTOM | GENERAL | 7.5763 | 983.54 | 7451.60 | LightsWired | LTG_SCH_OFFICE | 46.59 | 168.00 | 45.39 | 0.0000 | Y | 63.48 |
CORE_MID_LIGHTS | CORE_MID | CORE_MID | GENERAL | 7.5763 | 983.54 | 7451.60 | LightsWired | LTG_SCH_OFFICE | 46.59 | 168.00 | 45.39 | 0.0000 | Y | 63.48 |
CORE_TOP_LIGHTS | CORE_TOP | CORE_TOP | GENERAL | 7.5763 | 983.54 | 7451.60 | LightsWired | LTG_SCH_OFFICE | 46.59 | 168.00 | 45.39 | 0.0000 | Y | 63.48 |
PERIMETER_TOP_ZN_3_LIGHTS | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3 | GENERAL | 7.5763 | 207.34 | 1570.86 | LightsWired | LTG_SCH_OFFICE | 46.59 | 168.00 | 31.25 | 0.0000 | Y | 9.22 |
PERIMETER_TOP_ZN_2_LIGHTS | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2 | GENERAL | 7.5763 | 131.26 | 994.49 | LightsWired | LTG_SCH_OFFICE | 46.59 | 168.00 | 31.22 | 0.0000 | Y | 5.83 |
PERIMETER_TOP_ZN_1_LIGHTS | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1 | GENERAL | 7.5763 | 207.34 | 1570.86 | LightsWired | LTG_SCH_OFFICE | 46.59 | 168.00 | 31.08 | 0.0000 | Y | 9.16 |
PERIMETER_TOP_ZN_4_LIGHTS | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4 | GENERAL | 7.5763 | 131.25 | 994.42 | LightsWired | LTG_SCH_OFFICE | 46.59 | 168.00 | 31.19 | 0.0000 | Y | 5.82 |
PERIMETER_BOT_ZN_3_LIGHTS | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3 | GENERAL | 7.5763 | 207.34 | 1570.86 | LightsWired | LTG_SCH_OFFICE | 46.59 | 168.00 | 31.21 | 0.0000 | Y | 9.20 |
PERIMETER_BOT_ZN_2_LIGHTS | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2 | GENERAL | 7.5763 | 131.26 | 994.49 | LightsWired | LTG_SCH_OFFICE | 46.59 | 168.00 | 31.19 | 0.0000 | Y | 5.82 |
PERIMETER_BOT_ZN_1_LIGHTS | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1 | GENERAL | 7.5763 | 207.34 | 1570.86 | LightsWired | LTG_SCH_OFFICE | 46.59 | 168.00 | 31.05 | 0.0000 | Y | 9.16 |
PERIMETER_BOT_ZN_4_LIGHTS | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4 | GENERAL | 7.5763 | 131.25 | 994.42 | LightsWired | LTG_SCH_OFFICE | 46.59 | 168.00 | 31.15 | 0.0000 | Y | 5.81 |
PERIMETER_MID_ZN_3_LIGHTS | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3 | GENERAL | 7.5763 | 207.34 | 1570.86 | LightsWired | LTG_SCH_OFFICE | 46.59 | 168.00 | 31.25 | 0.0000 | Y | 9.22 |
PERIMETER_MID_ZN_2_LIGHTS | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2 | GENERAL | 7.5763 | 131.26 | 994.49 | LightsWired | LTG_SCH_OFFICE | 46.59 | 168.00 | 31.22 | 0.0000 | Y | 5.83 |
PERIMETER_MID_ZN_1_LIGHTS | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1 | GENERAL | 7.5763 | 207.34 | 1570.86 | LightsWired | LTG_SCH_OFFICE | 46.59 | 168.00 | 31.08 | 0.0000 | Y | 9.16 |
PERIMETER_MID_ZN_4_LIGHTS | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4 | GENERAL | 7.5763 | 131.25 | 994.42 | LightsWired | LTG_SCH_OFFICE | 46.59 | 168.00 | 31.19 | 0.0000 | Y | 5.82 |
Interior Lighting Total | 7.5763 | 4982.19 | 37746.71 | 280.51 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
PERIMETER_BOT_ZN_1_DAYLREFPT1 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 1570.86 | 602.43 |
PERIMETER_BOT_ZN_1_DAYLREFPT2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.00 | 1570.86 | 0.00 |
PERIMETER_BOT_ZN_2_DAYLREFPT1 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 994.49 | 381.39 |
PERIMETER_BOT_ZN_2_DAYLREFPT2 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.00 | 994.49 | 0.00 |
PERIMETER_BOT_ZN_3_DAYLREFPT1 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 1570.86 | 602.43 |
PERIMETER_BOT_ZN_3_DAYLREFPT2 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.00 | 1570.86 | 0.00 |
PERIMETER_BOT_ZN_4_DAYLREFPT1 | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 994.42 | 381.36 |
PERIMETER_BOT_ZN_4_DAYLREFPT2 | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.00 | 994.42 | 0.00 |
PERIMETER_MID_ZN_1_DAYLREFPT1 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 1570.86 | 602.43 |
PERIMETER_MID_ZN_1_DAYLREFPT2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.00 | 1570.86 | 0.00 |
PERIMETER_MID_ZN_2_DAYLREFPT1 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 994.49 | 381.39 |
PERIMETER_MID_ZN_2_DAYLREFPT2 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.00 | 994.49 | 0.00 |
PERIMETER_MID_ZN_3_DAYLREFPT1 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 1570.86 | 602.43 |
PERIMETER_MID_ZN_3_DAYLREFPT2 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.00 | 1570.86 | 0.00 |
PERIMETER_MID_ZN_4_DAYLREFPT1 | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 994.42 | 381.36 |
PERIMETER_MID_ZN_4_DAYLREFPT2 | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.00 | 994.42 | 0.00 |
PERIMETER_TOP_ZN_1_DAYLREFPT1 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 1570.86 | 602.43 |
PERIMETER_TOP_ZN_1_DAYLREFPT2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.00 | 1570.86 | 0.00 |
PERIMETER_TOP_ZN_2_DAYLREFPT1 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 994.49 | 381.39 |
PERIMETER_TOP_ZN_2_DAYLREFPT2 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.00 | 994.49 | 0.00 |
PERIMETER_TOP_ZN_3_DAYLREFPT1 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 1570.86 | 602.43 |
PERIMETER_TOP_ZN_3_DAYLREFPT2 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.00 | 1570.86 | 0.00 |
PERIMETER_TOP_ZN_4_DAYLREFPT1 | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 994.42 | 381.36 |
PERIMETER_TOP_ZN_4_DAYLREFPT2 | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.00 | 994.42 | 0.00 |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS_A | 424.83 | AstronomicalClock | - | 41.75 | 41.75 | 3.33 | |
EXTERIOR_LIGHTS_B | 5132.60 | AstronomicalClock | - | 83.75 | 71.15 | 68.55 | |
Exterior Lighting Total | 5557.43 | 71.88 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
Central PlantType | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | 119051.26 | 87422.98 | 31628.28 | 0.73 | 3.40 | |||
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | 107988.03 | 78239.09 | 29748.94 | 0.72 | 3.40 | |||
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed | 126246.03 | 93327.69 | 32918.34 | 0.74 | 3.40 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
PACU_VAV_BOT COOLING COIL | 118459.8 | 2.93 | 10.01 | N/A | N/A | 11.49 | |
PACU_VAV_MID COOLING COIL | 107558.7 | 2.94 | 10.05 | N/A | N/A | 11.55 | |
PACU_VAV_TOP COOLING COIL | 125555.9 | 2.93 | 9.99 | N/A | N/A | 11.47 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | ||||||||
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | ||||||||
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
CORE_BOTTOM VAV BOX REHEAT COIL | Coil:Heating:Electric | 25807.74 | 1.00 | |
CORE_MID VAV BOX REHEAT COIL | Coil:Heating:Electric | 24952.43 | 1.00 | |
CORE_TOP VAV BOX REHEAT COIL | Coil:Heating:Electric | 26295.84 | 1.00 | |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | 10498.13 | 1.00 | |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | 6855.36 | 1.00 | |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | 10490.86 | 1.00 | |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | 6863.97 | 1.00 | |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | 6309.14 | 1.00 | |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | 4178.27 | 1.00 | |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | 6309.14 | 1.00 | |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | 4189.06 | 1.00 | |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | 7441.59 | 1.00 | |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | 4902.76 | 1.00 | |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | 7432.94 | 1.00 | |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | 4912.33 | 1.00 | |
PACU_VAV_BOT HEATING COIL | Coil:Heating:Fuel | 5376.56 | 0.80 | |
PACU_VAV_MID HEATING COIL | Coil:Heating:Fuel | 7180.07 | 0.80 | |
PACU_VAV_TOP HEATING COIL | Coil:Heating:Fuel | 4155.39 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
PACU_VAV_BOT FAN | Fan:VariableVolume | 0.60 | 1314.72 | 5.31 | 11543.50 | 2174.89 | 1.00 | 1.14 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:20:00 |
PACU_VAV_MID FAN | Fan:VariableVolume | 0.60 | 1314.72 | 4.68 | 10235.27 | 2189.01 | 1.00 | 1.14 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:30:00 |
PACU_VAV_TOP FAN | Fan:VariableVolume | 0.60 | 1314.72 | 5.71 | 12418.07 | 2174.89 | 1.00 | 1.13 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:40:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
SWHSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 3168.45 | 0.000054 | 0.73 | 13540.37 | 0.30 | General |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SWHSYS1 WATER HEATER | WaterHeater:Mixed | 0.38 | 29307.11 | 0.81 | 1.02 | 0.24 |
DX Cooling Coil Type | Assocated Fan | Net Cooling Capacity [W] | COP [W/W] | EER [Btu/W-h] | IEER [Btu/W-h] | Supply Air Flow 100% [kg/s] | COP 75% Capacity [W/W] | EER 75% Capacity [Btu/W-h] | Supply Air Flow 75% [kg/s] | COP 50% Capacity [W/W] | EER 50% Capacity [Btu/W-h] | Supply Air Flow 50% [kg/s] | COP 25% Capacity [W/W] | EER 25% Capacity [Btu/W-h] | Supply Air Flow 25% [kg/s] | |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | None | 118459.78 | 2.93 | 10.01 | 11.49 | 5.9840 | 3.29 | 11.24 | 4.7661 | 3.47 | 11.85 | 3.2083 | 3.61 | 12.33 | 1.3370 |
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | None | 107558.74 | 2.94 | 10.05 | 11.55 | 5.2716 | 3.31 | 11.30 | 4.1945 | 3.49 | 11.91 | 2.8235 | 3.63 | 12.37 | 1.1877 |
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed | None | 125555.90 | 2.93 | 9.99 | 11.47 | 6.4373 | 3.28 | 11.21 | 5.1294 | 3.46 | 11.81 | 3.4532 | 3.61 | 12.31 | 1.4318 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
CORE_BOTTOM | 39716.37 | 39716.37 | 40.38 | 2.936 | 2.936 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:00:00 | 24.00 | 24.00 | 0.00881 | 34.82 | 0.00915 | 0.425 | 0.00 |
CORE_MID | 29911.21 | 29911.21 | 30.41 | 2.209 | 2.209 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:00:00 | 24.00 | 24.00 | 0.00891 | 34.82 | 0.00915 | 0.425 | 0.00 |
CORE_TOP | 33653.28 | 33653.28 | 34.22 | 2.508 | 2.508 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:20:00 | 24.00 | 24.00 | 0.00886 | 41.81 | 0.00916 | 0.425 | 0.00 |
PERIMETER_TOP_ZN_3 | 12264.36 | 12264.36 | 59.15 | 0.914 | 0.914 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:30:00 | 24.00 | 24.00 | 0.00872 | 41.71 | 0.00916 | 0.090 | 0.00 |
PERIMETER_TOP_ZN_2 | 9271.16 | 9271.16 | 70.63 | 0.691 | 0.691 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 10:50:00 | 24.00 | 24.00 | 0.00868 | 39.53 | 0.00915 | 0.057 | 0.00 |
PERIMETER_TOP_ZN_1 | 12466.07 | 12466.07 | 60.12 | 0.929 | 0.929 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 14:40:00 | 24.00 | 24.00 | 0.00871 | 42.00 | 0.00916 | 0.090 | 0.00 |
PERIMETER_TOP_ZN_4 | 10320.05 | 10320.05 | 78.63 | 0.769 | 0.769 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 16:20:00 | 24.00 | 24.00 | 0.00866 | 41.16 | 0.00916 | 0.057 | 0.00 |
PERIMETER_BOT_ZN_3 | 9930.24 | 9930.24 | 47.89 | 0.740 | 0.740 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:20:00 | 24.00 | 24.00 | 0.00876 | 41.81 | 0.00916 | 0.090 | 0.00 |
PERIMETER_BOT_ZN_2 | 8002.63 | 8002.63 | 60.97 | 0.596 | 0.596 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 10:50:00 | 24.00 | 24.00 | 0.00871 | 39.53 | 0.00915 | 0.057 | 0.00 |
PERIMETER_BOT_ZN_1 | 10111.11 | 10111.11 | 48.77 | 0.754 | 0.754 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 14:10:00 | 24.00 | 24.00 | 0.00876 | 42.00 | 0.00916 | 0.090 | 0.00 |
PERIMETER_BOT_ZN_4 | 8327.68 | 8327.68 | 63.45 | 0.621 | 0.621 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 16:30:00 | 24.00 | 24.00 | 0.00870 | 41.03 | 0.00916 | 0.057 | 0.00 |
PERIMETER_MID_ZN_3 | 10286.22 | 10286.22 | 49.61 | 0.767 | 0.767 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:30:00 | 24.00 | 24.00 | 0.00876 | 41.71 | 0.00916 | 0.090 | 0.00 |
PERIMETER_MID_ZN_2 | 8445.64 | 8445.64 | 64.34 | 0.630 | 0.630 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 10:30:00 | 24.00 | 24.00 | 0.00870 | 39.04 | 0.00915 | 0.057 | 0.00 |
PERIMETER_MID_ZN_1 | 10497.13 | 10497.13 | 50.63 | 0.782 | 0.782 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 14:20:00 | 24.00 | 24.00 | 0.00875 | 42.00 | 0.00916 | 0.090 | 0.00 |
PERIMETER_MID_ZN_4 | 8923.89 | 8923.89 | 67.99 | 0.665 | 0.665 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 16:20:00 | 24.00 | 24.00 | 0.00869 | 41.16 | 0.00916 | 0.057 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
CORE_BOTTOM | 2822.81 | 2822.81 | 2.87 | 0.123 | 0.425 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00800 | 6.30 | 0.00607 | 0.425 | 0.00 |
CORE_MID | 8932.78 | 8932.78 | 9.08 | 0.386 | 0.425 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00800 | 6.30 | 0.00607 | 0.425 | 0.00 |
CORE_TOP | 17989.30 | 17989.30 | 18.29 | 0.782 | 0.782 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00800 | 6.30 | 0.00607 | 0.425 | 0.00 |
PERIMETER_TOP_ZN_3 | 7383.83 | 7383.83 | 35.61 | 0.322 | 0.322 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00796 | 6.30 | 0.00607 | 0.090 | 0.00 |
PERIMETER_TOP_ZN_2 | 4821.09 | 4821.09 | 36.73 | 0.211 | 0.211 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00796 | 6.30 | 0.00607 | 0.057 | 0.00 |
PERIMETER_TOP_ZN_1 | 7378.74 | 7378.74 | 35.59 | 0.322 | 0.322 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00796 | 6.30 | 0.00607 | 0.090 | 0.00 |
PERIMETER_TOP_ZN_4 | 4827.12 | 4827.12 | 36.78 | 0.211 | 0.211 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00796 | 6.30 | 0.00607 | 0.057 | 0.00 |
PERIMETER_BOT_ZN_3 | 4448.99 | 4448.99 | 21.46 | 0.194 | 0.194 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00794 | 6.30 | 0.00607 | 0.090 | 0.00 |
PERIMETER_BOT_ZN_2 | 2945.33 | 2945.33 | 22.44 | 0.128 | 0.128 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00794 | 6.30 | 0.00607 | 0.057 | 0.00 |
PERIMETER_BOT_ZN_1 | 4448.99 | 4448.99 | 21.46 | 0.194 | 0.194 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00794 | 6.30 | 0.00607 | 0.090 | 0.00 |
PERIMETER_BOT_ZN_4 | 2952.88 | 2952.88 | 22.50 | 0.129 | 0.129 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00794 | 6.30 | 0.00607 | 0.057 | 0.00 |
PERIMETER_MID_ZN_3 | 5241.84 | 5241.84 | 25.28 | 0.229 | 0.229 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00793 | 6.30 | 0.00607 | 0.090 | 0.00 |
PERIMETER_MID_ZN_2 | 3452.70 | 3452.70 | 26.30 | 0.151 | 0.151 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00794 | 6.30 | 0.00607 | 0.057 | 0.00 |
PERIMETER_MID_ZN_1 | 5235.78 | 5235.78 | 25.25 | 0.228 | 0.228 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00793 | 6.30 | 0.00607 | 0.090 | 0.00 |
PERIMETER_MID_ZN_4 | 3459.40 | 3459.40 | 26.36 | 0.151 | 0.151 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.00 | 21.00 | 0.00794 | 6.30 | 0.00607 | 0.057 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PACU_VAV_BOT | 5.31 | 5.31 | 1.07 | 1.07 | 5.3076 | 1.3707 | 5.3076 | 0.2583 | 0.3000 |
PACU_VAV_MID | 4.68 | 4.68 | 1.18 | 1.18 | 4.6757 | 1.3491 | 4.6757 | 0.2885 | 0.3000 |
PACU_VAV_TOP | 5.71 | 5.71 | 1.85 | 1.85 | 5.7097 | 1.8485 | 5.7097 | 0.3237 | 0.3000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
CORE_BOTTOM VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_BOTTOM VAV BOX | 25807.738 | 25807.738 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 25807.74 | 13826.37 | 0.424691 | 12.80 | 11.37 | 0.00800000 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 0.0000 | 21.00 | 0.00799854 | 50.4035 | 2822.81 | 0.00 | -999.00 | -999.00 |
CORE_MID VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_MID VAV BOX | 24952.434 | 24952.434 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 24952.43 | 13826.37 | 0.424691 | 12.80 | 11.37 | 0.00800000 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 0.0000 | 21.00 | 0.00800000 | 50.4125 | 8932.78 | 0.00 | -999.00 | -999.00 |
CORE_TOP VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_TOP VAV BOX | 26295.837 | 26295.837 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 26295.84 | 25471.32 | 0.782378 | 12.80 | 11.37 | 0.00800000 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 0.0000 | 21.00 | 0.00800000 | 50.4125 | 17989.30 | 0.00 | -999.00 | -999.00 |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_3 VAV BOX | 10498.126 | 10498.126 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 10498.13 | 10498.13 | 0.322461 | 12.80 | 11.37 | 0.00800000 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 0.0000 | 21.00 | 0.00796438 | 50.1913 | 7383.83 | 0.00 | -999.00 | -999.00 |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_2 VAV BOX | 6855.358 | 6855.358 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6855.36 | 6855.36 | 0.210569 | 12.80 | 11.37 | 0.00800000 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 0.0000 | 21.00 | 0.00796479 | 50.1938 | 4821.09 | 0.00 | -999.00 | -999.00 |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_1 VAV BOX | 10490.858 | 10490.858 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 10490.86 | 10490.86 | 0.322237 | 12.80 | 11.37 | 0.00800000 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 0.0000 | 21.00 | 0.00796433 | 50.1910 | 7378.74 | 0.00 | -999.00 | -999.00 |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_4 VAV BOX | 6863.970 | 6863.970 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6863.97 | 6863.97 | 0.210834 | 12.80 | 11.37 | 0.00800000 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 0.0000 | 21.00 | 0.00796487 | 50.1944 | 4827.12 | 0.00 | -999.00 | -999.00 |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_3 VAV BOX | 6309.140 | 6309.140 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6309.14 | 6309.14 | 0.193792 | 12.80 | 11.37 | 0.00800000 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 0.0000 | 21.00 | 0.00793706 | 50.0214 | 4448.99 | 0.00 | -999.00 | -999.00 |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_2 VAV BOX | 4178.266 | 4178.266 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 4178.27 | 4178.27 | 0.128340 | 12.80 | 11.37 | 0.00800000 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 0.0000 | 21.00 | 0.00793811 | 50.0279 | 2945.33 | 0.00 | -999.00 | -999.00 |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_1 VAV BOX | 6309.136 | 6309.136 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6309.14 | 6309.14 | 0.193792 | 12.80 | 11.37 | 0.00800000 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 0.0000 | 21.00 | 0.00793706 | 50.0214 | 4448.99 | 0.00 | -999.00 | -999.00 |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_4 VAV BOX | 4189.062 | 4189.062 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 4189.06 | 4189.06 | 0.128671 | 12.80 | 11.37 | 0.00800000 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 0.0000 | 21.00 | 0.00793836 | 50.0295 | 2952.88 | 0.00 | -999.00 | -999.00 |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_3 VAV BOX | 7441.590 | 7441.590 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 7441.59 | 7441.59 | 0.228576 | 12.80 | 11.37 | 0.00800000 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 0.0000 | 21.00 | 0.00793405 | 50.0028 | 5241.84 | 0.00 | -999.00 | -999.00 |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_2 VAV BOX | 4902.764 | 4902.764 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 4902.76 | 4902.76 | 0.150593 | 12.80 | 11.37 | 0.00800000 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 0.0000 | 21.00 | 0.00793595 | 50.0146 | 3452.70 | 0.00 | -999.00 | -999.00 |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_1 VAV BOX | 7432.938 | 7432.938 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 7432.94 | 7432.94 | 0.228310 | 12.80 | 11.37 | 0.00800000 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 0.0000 | 21.00 | 0.00793389 | 50.0017 | 5235.78 | 0.00 | -999.00 | -999.00 |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_4 VAV BOX | 4912.331 | 4912.331 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 4912.33 | 4912.33 | 0.150887 | 12.80 | 11.37 | 0.00800000 | 40.00 | 20.89 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 0.0000 | 21.00 | 0.00793621 | 50.0162 | 3459.40 | 0.00 | -999.00 | -999.00 |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoopHVAC | PACU_VAV_BOT | 119051.262 | 87422.977 | 5.307631 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:20:00 | 110283.12 | 104524.05 | 5.307631 | 28.05 | 17.82 | 0.00887096 | 10.99 | 10.99 | 0.00850000 | 42.00 | 0.00915790 | 22.26 | 22.5180 | 24.00 | 0.00878751 | 46.0927 | 71170.52 | 0.00 | 122757.83 | 87826.58 |
PACU_VAV_BOT HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PACU_VAV_BOT | 5376.558 | 5376.558 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 5376.56 | 5376.56 | 1.592289 | 9.94 | 8.57 | 0.00654357 | 12.80 | 11.37 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 75.0599 | 21.00 | 0.00794730 | 50.0850 | 17619.00 | 0.00 | -999.00 | -999.00 |
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoopHVAC | PACU_VAV_MID | 107988.033 | 78239.092 | 4.675749 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:30:00 | 100603.59 | 94960.70 | 4.675749 | 28.61 | 18.04 | 0.00891312 | 10.97 | 10.97 | 0.00850000 | 42.00 | 0.00915790 | 22.26 | 25.5610 | 24.00 | 0.00882882 | 46.3064 | 62592.69 | 0.00 | 111350.16 | 78654.99 |
PACU_VAV_MID HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PACU_VAV_MID | 7180.069 | 7180.069 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 7180.07 | 7180.07 | 1.402725 | 8.46 | 7.67 | 0.00635139 | 12.80 | 11.37 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 85.2035 | 21.00 | 0.00795680 | 50.1441 | 26322.49 | 0.00 | -999.00 | -999.00 |
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoopHVAC | PACU_VAV_TOP | 126246.034 | 93327.693 | 5.709749 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:40:00 | 116631.49 | 110741.53 | 5.709749 | 27.78 | 17.71 | 0.00885234 | 10.99 | 10.99 | 0.00850000 | 42.00 | 0.00915790 | 22.26 | 20.9321 | 24.00 | 0.00877107 | 46.0077 | 76325.37 | 0.00 | 130176.61 | 93729.14 |
PACU_VAV_TOP HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PACU_VAV_TOP | 4155.386 | 4155.386 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 18:10:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 4155.39 | 4155.39 | 1.712925 | 10.74 | 9.05 | 0.00664870 | 12.80 | 11.37 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 69.7736 | 21.00 | 0.00797916 | 50.2830 | 27203.61 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
CORE_BOTTOM VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_BOTTOM VAV BOX | CORE_BOTTOM | N/A | N/A | N/A | Yes | No | unknown | No | 25807.738 | 25807.738 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 25807.74 | 13826.37 | 1.0000 | 0.49849623 | 0.424691 | 12.80 | 11.37 | 0.00800000 | 33059.8 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 25807.74 | 6.30 | 0.00607234 | 6.30 | 0.00000000 | 0.0000 | 20.84 | 0.00799854 | 21.00 | 0.00799854 | 50.4035 | 2822.81 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
CORE_MID VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_MID VAV BOX | CORE_MID | N/A | N/A | N/A | Yes | No | unknown | No | 24952.434 | 24952.434 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 24952.43 | 13826.37 | 1.0000 | 0.49849623 | 0.424691 | 12.80 | 11.37 | 0.00800000 | 33059.8 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 24952.43 | 6.30 | 0.00607234 | 6.30 | 0.00000000 | 0.0000 | 20.88 | 0.00800000 | 21.00 | 0.00800000 | 50.4125 | 8932.78 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
CORE_TOP VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_TOP VAV BOX | CORE_TOP | N/A | N/A | N/A | Yes | No | unknown | No | 26295.837 | 26295.837 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 26295.84 | 25471.32 | 1.0000 | 0.91834371 | 0.782378 | 12.80 | 11.37 | 0.00800000 | 33059.8 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 26295.84 | 6.30 | 0.00607234 | 6.30 | 0.00000000 | 0.0000 | 20.92 | 0.00800000 | 21.00 | 0.00800000 | 50.4125 | 17989.30 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_3 VAV BOX | PERIMETER_TOP_ZN_3 | N/A | N/A | N/A | Yes | No | unknown | No | 10498.126 | 10498.126 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 10498.13 | 10498.13 | 1.0000 | 0.37849966 | 0.322461 | 12.80 | 11.37 | 0.00800000 | 33059.8 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10498.13 | 6.30 | 0.00607234 | 6.30 | 0.00000000 | 0.0000 | 20.95 | 0.00796438 | 21.00 | 0.00796438 | 50.1913 | 7383.83 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_2 VAV BOX | PERIMETER_TOP_ZN_2 | N/A | N/A | N/A | Yes | No | unknown | No | 6855.358 | 6855.358 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 6855.36 | 6855.36 | 1.0000 | 0.24716323 | 0.210569 | 12.80 | 11.37 | 0.00800000 | 33059.8 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6855.36 | 6.30 | 0.00607234 | 6.30 | 0.00000000 | 0.0000 | 20.95 | 0.00796479 | 21.00 | 0.00796479 | 50.1938 | 4821.09 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_1 VAV BOX | PERIMETER_TOP_ZN_1 | N/A | N/A | N/A | Yes | No | unknown | No | 10490.858 | 10490.858 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 10490.86 | 10490.86 | 1.0000 | 0.37823763 | 0.322237 | 12.80 | 11.37 | 0.00800000 | 33059.8 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10490.86 | 6.30 | 0.00607234 | 6.30 | 0.00000000 | 0.0000 | 20.95 | 0.00796433 | 21.00 | 0.00796433 | 50.1910 | 7378.74 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_4 VAV BOX | PERIMETER_TOP_ZN_4 | N/A | N/A | N/A | Yes | No | unknown | No | 6863.970 | 6863.970 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 6863.97 | 6863.97 | 1.0000 | 0.24747374 | 0.210834 | 12.80 | 11.37 | 0.00800000 | 33059.8 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6863.97 | 6.30 | 0.00607234 | 6.30 | 0.00000000 | 0.0000 | 20.95 | 0.00796487 | 21.00 | 0.00796487 | 50.1944 | 4827.12 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_3 VAV BOX | PERIMETER_BOT_ZN_3 | N/A | N/A | N/A | Yes | No | unknown | No | 6309.140 | 6309.140 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 6309.14 | 6309.14 | 1.0000 | 0.22746986 | 0.193792 | 12.80 | 11.37 | 0.00800000 | 33059.8 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6309.14 | 6.30 | 0.00607234 | 6.30 | 0.00000000 | 0.0000 | 20.92 | 0.00793706 | 21.00 | 0.00793706 | 50.0214 | 4448.99 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_2 VAV BOX | PERIMETER_BOT_ZN_2 | N/A | N/A | N/A | Yes | No | unknown | No | 4178.266 | 4178.266 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 4178.27 | 4178.27 | 1.0000 | 0.15064331 | 0.128340 | 12.80 | 11.37 | 0.00800000 | 33059.8 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 4178.27 | 6.30 | 0.00607234 | 6.30 | 0.00000000 | 0.0000 | 20.92 | 0.00793811 | 21.00 | 0.00793811 | 50.0279 | 2945.33 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_1 VAV BOX | PERIMETER_BOT_ZN_1 | N/A | N/A | N/A | Yes | No | unknown | No | 6309.136 | 6309.136 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 6309.14 | 6309.14 | 1.0000 | 0.22746975 | 0.193792 | 12.80 | 11.37 | 0.00800000 | 33059.8 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6309.14 | 6.30 | 0.00607234 | 6.30 | 0.00000000 | 0.0000 | 20.92 | 0.00793706 | 21.00 | 0.00793706 | 50.0214 | 4448.99 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_4 VAV BOX | PERIMETER_BOT_ZN_4 | N/A | N/A | N/A | Yes | No | unknown | No | 4189.062 | 4189.062 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 4189.06 | 4189.06 | 1.0000 | 0.15103253 | 0.128671 | 12.80 | 11.37 | 0.00800000 | 33059.8 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 4189.06 | 6.30 | 0.00607234 | 6.30 | 0.00000000 | 0.0000 | 20.92 | 0.00793836 | 21.00 | 0.00793836 | 50.0295 | 2952.88 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_3 VAV BOX | PERIMETER_MID_ZN_3 | N/A | N/A | N/A | Yes | No | unknown | No | 7441.590 | 7441.590 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 7441.59 | 7441.59 | 1.0000 | 0.26829926 | 0.228576 | 12.80 | 11.37 | 0.00800000 | 33059.8 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7441.59 | 6.30 | 0.00607234 | 6.30 | 0.00000000 | 0.0000 | 20.91 | 0.00793405 | 21.00 | 0.00793405 | 50.0028 | 5241.84 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_2 VAV BOX | PERIMETER_MID_ZN_2 | N/A | N/A | N/A | Yes | No | unknown | No | 4902.764 | 4902.764 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 4902.76 | 4902.76 | 1.0000 | 0.17676437 | 0.150593 | 12.80 | 11.37 | 0.00800000 | 33059.8 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 4902.76 | 6.30 | 0.00607234 | 6.30 | 0.00000000 | 0.0000 | 20.91 | 0.00793595 | 21.00 | 0.00793595 | 50.0146 | 3452.70 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_1 VAV BOX | PERIMETER_MID_ZN_1 | N/A | N/A | N/A | Yes | No | unknown | No | 7432.938 | 7432.938 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 7432.94 | 7432.94 | 1.0000 | 0.26798733 | 0.228310 | 12.80 | 11.37 | 0.00800000 | 33059.8 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7432.94 | 6.30 | 0.00607234 | 6.30 | 0.00000000 | 0.0000 | 20.91 | 0.00793389 | 21.00 | 0.00793389 | 50.0017 | 5235.78 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_4 VAV BOX | PERIMETER_MID_ZN_4 | N/A | N/A | N/A | Yes | No | unknown | No | 4912.331 | 4912.331 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 4912.33 | 4912.33 | 1.0000 | 0.17710931 | 0.150887 | 12.80 | 11.37 | 0.00800000 | 33059.8 | 40.00 | 20.89 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 4912.33 | 6.30 | 0.00607234 | 6.30 | 0.00000000 | 0.0000 | 20.91 | 0.00793621 | 21.00 | 0.00793621 | 50.0162 | 3459.40 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoop | AirLoopHVAC | PACU_VAV_BOT | CORE_BOTTOM; PERIMETER_BOT_ZN_1; PERIMETER_BOT_ZN_2; PERIMETER_BOT_ZN_3; PERIMETER_BOT_ZN_4; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 119051.262 | 87422.977 | 5.307631 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.3307 | 1004.8586 | 1.1738 | PACU_VAV_BOT FAN | Fan:VariableVolume | 5.307631 | 6.23002019 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:20:00 | Sensible | 110283.12 | 104524.05 | 0.9263 | 6.23002019 | 5.307631 | 28.05 | 17.82 | 0.00887096 | 50838.7 | 10.99 | 10.99 | 0.00850000 | 32470.6 | -999.0 | -999.00 | -999.00 | -999.00 | 11543.505 | 98739.61 | 42.00 | 0.00915790 | 22.26 | 1.19517000 | 22.5180 | 24.00 | 0.00878751 | 24.00 | 0.00878751 | 46.0927 | 71170.52 | 0.00 | 122757.83 | 87826.58 | 5.98398148 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 12.30 | 12.29 | 0.00889592 | 34808.0 | |
PACU_VAV_BOT HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PACU_VAV_BOT | CORE_BOTTOM; PERIMETER_BOT_ZN_1; PERIMETER_BOT_ZN_2; PERIMETER_BOT_ZN_3; PERIMETER_BOT_ZN_4; | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 5376.558 | 5376.558 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | PACU_VAV_BOT FAN | Fan:VariableVolume | 5.307631 | 6.23002019 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 5376.56 | 5376.56 | 1.0000 | 1.86900606 | 1.592289 | 9.94 | 8.57 | 0.00654357 | 26471.3 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5376.56 | 6.30 | 0.00607234 | 6.30 | 1.19517000 | 75.0599 | 20.88 | 0.00796176 | 21.00 | 0.00794730 | 50.0850 | 17619.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoop | AirLoopHVAC | PACU_VAV_MID | CORE_MID; PERIMETER_MID_ZN_1; PERIMETER_MID_ZN_2; PERIMETER_MID_ZN_3; PERIMETER_MID_ZN_4; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 107988.033 | 78239.092 | 4.675749 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.4090 | 1004.8586 | 1.1738 | PACU_VAV_MID FAN | Fan:VariableVolume | 4.675749 | 5.48832626 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:30:00 | Sensible | 100603.59 | 94960.70 | 0.9316 | 5.48832626 | 4.675749 | 28.61 | 18.04 | 0.00891312 | 51514.0 | 10.97 | 10.97 | 0.00850000 | 32458.7 | -999.0 | -999.00 | -999.00 | -999.00 | 10235.266 | 90368.33 | 42.00 | 0.00915790 | 22.26 | 1.19517000 | 25.5610 | 24.00 | 0.00882882 | 24.00 | 0.00882882 | 46.3064 | 62592.69 | 0.00 | 111350.16 | 78654.99 | 5.27157886 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 12.05 | 12.04 | 0.00875293 | 34199.7 | |
PACU_VAV_MID HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PACU_VAV_MID | CORE_MID; PERIMETER_MID_ZN_1; PERIMETER_MID_ZN_2; PERIMETER_MID_ZN_3; PERIMETER_MID_ZN_4; | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 7180.069 | 7180.069 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | PACU_VAV_MID FAN | Fan:VariableVolume | 4.675749 | 5.48832626 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 7180.07 | 7180.07 | 1.0000 | 1.64649788 | 1.402725 | 8.46 | 7.67 | 0.00635139 | 24485.5 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7180.07 | 6.30 | 0.00607234 | 6.30 | 1.19517000 | 85.2035 | 20.90 | 0.00795821 | 21.00 | 0.00795680 | 50.1441 | 26322.49 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoop | AirLoopHVAC | PACU_VAV_TOP | CORE_TOP; PERIMETER_TOP_ZN_1; PERIMETER_TOP_ZN_2; PERIMETER_TOP_ZN_3; PERIMETER_TOP_ZN_4; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 126246.034 | 93327.693 | 5.709749 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.2961 | 1004.8586 | 1.1738 | PACU_VAV_TOP FAN | Fan:VariableVolume | 5.709749 | 6.70202046 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 15:40:00 | Sensible | 116631.49 | 110741.53 | 0.9238 | 6.70202046 | 5.709749 | 27.78 | 17.71 | 0.00885234 | 50511.4 | 10.99 | 10.99 | 0.00850000 | 32470.5 | -999.0 | -999.00 | -999.00 | -999.00 | 12418.067 | 104213.42 | 42.00 | 0.00915790 | 22.26 | 1.19517000 | 20.9321 | 24.00 | 0.00877107 | 24.00 | 0.00877107 | 46.0077 | 76325.37 | 0.00 | 130176.61 | 93729.14 | 6.43734132 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 12.41 | 12.40 | 0.00896476 | 35100.3 | |
PACU_VAV_TOP HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PACU_VAV_TOP | CORE_TOP; PERIMETER_TOP_ZN_1; PERIMETER_TOP_ZN_2; PERIMETER_TOP_ZN_3; PERIMETER_TOP_ZN_4; | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 4155.386 | 4155.386 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | PACU_VAV_TOP FAN | Fan:VariableVolume | 5.709749 | 6.70202046 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 18:10:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | Sensible | 4155.39 | 4155.39 | 1.0000 | 2.01060614 | 1.712925 | 10.74 | 9.05 | 0.00664870 | 27556.0 | 12.80 | 11.37 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 4155.39 | 6.30 | 0.00607234 | 6.30 | 1.19517000 | 69.7736 | 21.00 | 0.00797916 | 21.00 | 0.00797916 | 50.2830 | 27203.61 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
CORE_BOTTOM | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
CORE_MID | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
CORE_TOP | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_3 | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_2 | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_1 | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_4 | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
CORE_BOTTOM | 4806.33 | 68.67 | 7.17 |
CORE_MID | 4063.50 | 786.67 | 2.17 |
CORE_TOP | 3771.00 | 1440.00 | 11.83 |
PERIMETER_TOP_ZN_3 | 3837.17 | 2100.33 | 464.50 |
PERIMETER_TOP_ZN_2 | 4078.17 | 1875.67 | 501.83 |
PERIMETER_TOP_ZN_1 | 4416.33 | 1526.50 | 513.00 |
PERIMETER_TOP_ZN_4 | 4028.50 | 2006.33 | 514.50 |
PERIMETER_BOT_ZN_3 | 3884.83 | 1625.83 | 214.33 |
PERIMETER_BOT_ZN_2 | 4318.17 | 1243.17 | 342.00 |
PERIMETER_BOT_ZN_1 | 4661.17 | 1875.33 | 1163.50 |
PERIMETER_BOT_ZN_4 | 4262.67 | 1402.17 | 337.00 |
PERIMETER_MID_ZN_3 | 3897.17 | 1732.50 | 333.17 |
PERIMETER_MID_ZN_2 | 3456.83 | 1440.50 | 409.17 |
PERIMETER_MID_ZN_1 | 4595.50 | 1192.50 | 439.50 |
PERIMETER_MID_ZN_4 | 4139.50 | 1648.17 | 393.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 |
Facility | 5247.00 | 3186.67 | 1499.83 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
CORE_BOTTOM | 0.00 | 2.33 | 0.00 | 0.00 |
CORE_MID | 0.00 | 0.17 | 0.00 | 0.00 |
CORE_TOP | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 0.00 | 63.67 | 0.00 | 39.00 |
PERIMETER_TOP_ZN_2 | 0.00 | 87.33 | 0.00 | 64.17 |
PERIMETER_TOP_ZN_1 | 0.00 | 97.83 | 0.00 | 70.00 |
PERIMETER_TOP_ZN_4 | 0.00 | 82.50 | 0.00 | 48.50 |
PERIMETER_BOT_ZN_3 | 0.00 | 27.50 | 0.00 | 18.00 |
PERIMETER_BOT_ZN_2 | 0.00 | 63.67 | 0.00 | 48.67 |
PERIMETER_BOT_ZN_1 | 41.50 | 465.67 | 41.50 | 451.00 |
PERIMETER_BOT_ZN_4 | 0.00 | 66.33 | 0.00 | 35.83 |
PERIMETER_MID_ZN_3 | 0.00 | 39.00 | 0.00 | 26.17 |
PERIMETER_MID_ZN_2 | 0.00 | 64.83 | 0.00 | 54.17 |
PERIMETER_MID_ZN_1 | 0.00 | 81.33 | 0.00 | 66.00 |
PERIMETER_MID_ZN_4 | 0.00 | 63.00 | 0.00 | 38.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 41.50 | 650.33 | 41.50 | 579.83 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
CORE_BOTTOM | 22.18 | 52.94 | 2698.04 | 0.514 | 0.000 | 0.000 | 0.000 |
CORE_MID | 22.18 | 52.94 | 2698.04 | 0.438 | 0.000 | 0.000 | 0.000 |
CORE_TOP | 22.18 | 52.94 | 2698.04 | 0.428 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_3 | 4.68 | 11.16 | 568.77 | 0.570 | 0.033 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_2 | 2.96 | 7.07 | 360.08 | 0.727 | 0.034 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_1 | 4.68 | 11.16 | 568.77 | 0.749 | 0.033 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_4 | 2.96 | 7.06 | 360.05 | 0.745 | 0.034 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_3 | 4.68 | 11.16 | 568.77 | 0.476 | 0.017 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_2 | 2.96 | 7.07 | 360.08 | 0.612 | 0.018 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_1 | 4.68 | 11.16 | 568.77 | 0.703 | 1.246 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_4 | 2.96 | 7.06 | 360.05 | 0.611 | 0.018 | 0.000 | 0.000 |
PERIMETER_MID_ZN_3 | 4.68 | 11.16 | 568.77 | 0.564 | 0.027 | 0.000 | 0.000 |
PERIMETER_MID_ZN_2 | 2.60 | 7.07 | 360.08 | 0.684 | 0.029 | 0.000 | 0.000 |
PERIMETER_MID_ZN_1 | 4.68 | 11.16 | 568.77 | 0.757 | 0.027 | 0.000 | 0.000 |
PERIMETER_MID_ZN_4 | 2.96 | 7.06 | 360.05 | 0.735 | 0.029 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
CORE_BOTTOM | 22.18 | 52.94 | 2698.04 | 0.000 | 0.000 | 0.000 | 0.000 |
CORE_MID | 22.18 | 52.94 | 2698.04 | 0.000 | 0.000 | 0.000 | 0.000 |
CORE_TOP | 22.18 | 52.94 | 2698.04 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_3 | 4.68 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_2 | 2.96 | 7.07 | 360.08 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_1 | 4.68 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_4 | 2.96 | 7.06 | 360.05 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_3 | 4.68 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_2 | 2.96 | 7.07 | 360.08 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_1 | 4.68 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_4 | 2.96 | 7.06 | 360.05 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_3 | 4.68 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_2 | 2.60 | 7.07 | 360.08 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_1 | 4.68 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_4 | 2.96 | 7.06 | 360.05 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
Mechanical Ventilation Parameters by ZoneAirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
CORE_BOTTOM | PACU_VAV_BOT | 22.18 | 52.94 | 2698.04 | 983.54 | 0.0000 | 0.425 |
CORE_MID | PACU_VAV_MID | 22.18 | 52.94 | 2698.04 | 983.54 | 0.0000 | 0.425 |
CORE_TOP | PACU_VAV_TOP | 22.18 | 52.94 | 2698.04 | 983.54 | 0.0000 | 0.425 |
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP | 4.68 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP | 2.96 | 7.07 | 360.08 | 131.26 | 0.0000 | 0.057 |
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP | 4.68 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP | 2.96 | 7.06 | 360.05 | 131.25 | 0.0000 | 0.057 |
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT | 4.68 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT | 2.96 | 7.07 | 360.08 | 131.26 | 0.0000 | 0.057 |
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT | 4.68 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT | 2.96 | 7.06 | 360.05 | 131.25 | 0.0000 | 0.057 |
PERIMETER_MID_ZN_3 | PACU_VAV_MID | 4.68 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_MID_ZN_2 | PACU_VAV_MID | 2.60 | 7.07 | 360.08 | 131.26 | 0.0000 | 0.057 |
PERIMETER_MID_ZN_1 | PACU_VAV_MID | 4.68 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_MID_ZN_4 | PACU_VAV_MID | 2.96 | 7.06 | 360.05 | 131.25 | 0.0000 | 0.057 |
Total Facility | 112.00 | 268.17 | 13667.13 | 4982.19 | 0.0000 | 2.151 |
Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
CORE_BOTTOM | 8691308.91 | 0.00 | 8691308.91 | 0.00 | 8691308.91 | 13393058.27 | 6785.57 | 221.55 | 1752.88 | 472.08 |
CORE_MID | 7362510.93 | 0.00 | 7362510.93 | 0.00 | 7362510.93 | 13393058.27 | 8342.75 | 76.85 | 340.40 | 379.87 |
CORE_TOP | 7222043.00 | 0.00 | 7222043.00 | 0.00 | 7222043.00 | 13393058.27 | 8655.11 | 23.28 | 81.61 | 406.81 |
PERIMETER_TOP_ZN_3 | 2006939.00 | 0.00 | 2006939.00 | 173897.85 | 2180836.85 | 2823374.22 | 4229.41 | 144.65 | 4385.93 | 406.81 |
PERIMETER_TOP_ZN_2 | 1608929.76 | 0.00 | 1608929.76 | 115931.20 | 1724860.96 | 1787429.43 | 3366.41 | 17.14 | 5376.45 | 406.81 |
PERIMETER_TOP_ZN_1 | 2595937.14 | 0.00 | 2595937.14 | 173897.85 | 2769834.99 | 2823374.22 | 3397.18 | 26.43 | 5336.39 | 406.81 |
PERIMETER_TOP_ZN_4 | 1665947.77 | 0.00 | 1665947.77 | 115931.20 | 1781878.97 | 1787312.18 | 3481.35 | 24.98 | 5253.67 | 406.81 |
PERIMETER_BOT_ZN_3 | 1705888.32 | 0.00 | 1705888.32 | 92461.45 | 1798349.77 | 2823374.22 | 6809.91 | 288.65 | 1661.44 | 472.08 |
PERIMETER_BOT_ZN_2 | 1373922.88 | 0.00 | 1373922.88 | 61640.59 | 1435563.48 | 1787429.43 | 4048.23 | 151.59 | 4560.19 | 472.08 |
PERIMETER_BOT_ZN_1 | 2449872.48 | 0.00 | 2449872.48 | 4106049.28 | 6555921.76 | 2823374.22 | 4793.88 | 209.58 | 3756.54 | 472.08 |
PERIMETER_BOT_ZN_4 | 1383600.38 | 0.00 | 1383600.38 | 61640.59 | 1445240.98 | 1787312.18 | 4334.06 | 121.56 | 4304.38 | 472.08 |
PERIMETER_MID_ZN_3 | 1968085.61 | 0.00 | 1968085.61 | 144757.29 | 2112842.90 | 2823374.22 | 5921.40 | 100.19 | 2738.40 | 379.87 |
PERIMETER_MID_ZN_2 | 1581231.15 | 0.00 | 1581231.15 | 96504.28 | 1677735.43 | 1787429.43 | 3476.14 | 40.96 | 5242.90 | 1288.88 |
PERIMETER_MID_ZN_1 | 2600871.46 | 0.00 | 2600871.46 | 144757.29 | 2745628.75 | 2823374.22 | 4695.22 | 109.10 | 3955.68 | 379.87 |
PERIMETER_MID_ZN_4 | 1628894.55 | 0.00 | 1628894.55 | 96504.28 | 1725398.83 | 1787312.18 | 3613.95 | 39.41 | 5106.63 | 379.87 |
Total Facility | 45845983.33 | 0.00 | 45845983.33 | 5383973.17 | 51229956.50 | 67843644.98 | 8759.06 | 1104.06 | 5805.81 | 1549.83 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
CORE_BOTTOM | 0.3729 | 0.0000 | 0.3729 | 0.0000 | 0.3729 | 0.4247 | 3993.21 | 217.28 | 1732.51 |
CORE_MID | 0.3180 | 0.0000 | 0.3180 | 0.0000 | 0.3180 | 0.4247 | 5532.02 | 76.39 | 334.59 |
CORE_TOP | 0.3103 | 0.0000 | 0.3103 | 0.0000 | 0.3103 | 0.4247 | 5841.22 | 23.01 | 78.77 |
PERIMETER_TOP_ZN_3 | 0.0871 | 0.0000 | 0.0871 | 0.0050 | 0.0920 | 0.0895 | 1809.97 | 139.75 | 3993.28 |
PERIMETER_TOP_ZN_2 | 0.0703 | 0.0000 | 0.0703 | 0.0033 | 0.0736 | 0.0567 | 954.09 | 16.91 | 4971.99 |
PERIMETER_TOP_ZN_1 | 0.1145 | 0.0000 | 0.1145 | 0.0050 | 0.1194 | 0.0895 | 982.91 | 24.28 | 4935.81 |
PERIMETER_TOP_ZN_4 | 0.0720 | 0.0000 | 0.0720 | 0.0033 | 0.0753 | 0.0567 | 1069.86 | 24.78 | 4848.36 |
PERIMETER_BOT_ZN_3 | 0.0727 | 0.0000 | 0.0727 | 0.0026 | 0.0753 | 0.0895 | 4034.00 | 275.72 | 1633.27 |
PERIMETER_BOT_ZN_2 | 0.0591 | 0.0000 | 0.0591 | 0.0018 | 0.0609 | 0.0567 | 1688.28 | 150.31 | 4104.41 |
PERIMETER_BOT_ZN_1 | 0.1073 | 0.0000 | 0.1073 | 0.1902 | 0.2975 | 0.0895 | 2046.08 | 194.32 | 3702.60 |
PERIMETER_BOT_ZN_4 | 0.0590 | 0.0000 | 0.0590 | 0.0018 | 0.0608 | 0.0567 | 1977.36 | 121.00 | 3844.64 |
PERIMETER_MID_ZN_3 | 0.0861 | 0.0000 | 0.0861 | 0.0041 | 0.0903 | 0.0895 | 3154.16 | 98.96 | 2689.88 |
PERIMETER_MID_ZN_2 | 0.0661 | 0.0000 | 0.0661 | 0.0028 | 0.0689 | 0.0567 | 978.32 | 29.97 | 4025.71 |
PERIMETER_MID_ZN_1 | 0.1157 | 0.0000 | 0.1157 | 0.0041 | 0.1198 | 0.0895 | 1933.51 | 107.22 | 3902.27 |
PERIMETER_MID_ZN_4 | 0.0711 | 0.0000 | 0.0711 | 0.0028 | 0.0738 | 0.0567 | 1174.16 | 39.26 | 4729.58 |
Total Facility | 1.9822 | 0.0000 | 1.9822 | 0.2268 | 2.2090 | 2.1513 | 5942.06 | 1074.95 | 5164.98 |
Mechanical Ventilation [m3] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
PACU_VAV_BOT | 21499571.25 | 0.00 | 21499571.25 | 22614548.33 | 3262.00 | 0.00 | 5498.00 | 472.08 |
PACU_VAV_MID | 20861694.51 | 0.00 | 20861694.51 | 22614548.33 | 3358.97 | 0.00 | 5401.03 | 379.87 |
PACU_VAV_TOP | 20804076.00 | 0.00 | 20804076.00 | 22614548.33 | 3337.60 | 0.00 | 5422.40 | 406.81 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
PACU_VAV_BOT | 0.9245 | 0.0000 | 0.9245 | 0.7171 | 917.08 | 0.00 | 5025.92 |
PACU_VAV_MID | 0.9098 | 0.0000 | 0.9098 | 0.7171 | 921.85 | 0.00 | 5021.15 |
PACU_VAV_TOP | 0.9013 | 0.0000 | 0.9013 | 0.7171 | 927.41 | 0.00 | 5015.59 |
No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
PACU_VAV_BOT | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5498.00 | 0.00 | 0.00 | 0.00 |
PACU_VAV_MID | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5401.03 | 0.00 | 0.00 | 0.00 |
PACU_VAV_TOP | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5422.40 | 0.00 | 0.00 | 0.00 |
No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
PACU_VAV_BOT | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0934 | 0.0000 | 0.0000 | 0.0000 |
PACU_VAV_MID | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0769 | 0.0000 | 0.0000 | 0.0000 |
PACU_VAV_TOP | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0681 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
Surfaces by ClassTotal | Outdoors | |
Wall | 72 | 24 |
Floor | 30 | 4 |
Roof | 26 | 1 |
Internal Mass | 15 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 18 | 18 |
Door | 6 | 6 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 3 |
Conditioned Zones | 18 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 3 |
Count | |
IDF Objects | 824 |
Defaulted Fields | 545 |
Fields with Defaults | 2229 |
Autosized Fields | 149 |
Autosizable Fields | 202 |
Autocalculated Fields | 155 |
Autocalculatable Fields | 276 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 2012.66 | 15539.06 | 29-MAY-17:20 | 200684.14 | 12-JUN-14:10 |
Electricity:Building | 1042.55 | 15341.49 | 01-JAN-08:40 | 74573.67 | 11-OCT-07:10 |
Electricity:Zone:CORE_BOTTOM | 310.83 | 4652.71 | 01-JAN-00:10 | 24063.48 | 02-JAN-08:10 |
Electricity:SpaceType:GENERAL | 1042.55 | 15341.49 | 01-JAN-08:40 | 74573.67 | 11-OCT-07:10 |
InteriorLights:Electricity | 280.51 | 1316.11 | 01-JAN-08:40 | 27011.40 | 11-OCT-07:10 |
InteriorLights:Electricity:Zone:CORE_BOTTOM | 63.48 | 307.97 | 01-JAN-00:10 | 5543.17 | 02-JAN-08:10 |
InteriorLights:Electricity:SpaceType:GENERAL | 280.51 | 1316.11 | 01-JAN-08:40 | 27011.40 | 11-OCT-07:10 |
LightsWired:InteriorLights:Electricity | 280.51 | 1316.11 | 01-JAN-08:40 | 27011.40 | 11-OCT-07:10 |
LightsWired:InteriorLights:Electricity:Zone:CORE_BOTTOM | 63.48 | 307.97 | 01-JAN-00:10 | 5543.17 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:SpaceType:GENERAL | 280.51 | 1316.11 | 01-JAN-08:40 | 27011.40 | 11-OCT-07:10 |
Electricity:Zone:CORE_MID | 190.09 | 2689.12 | 01-JAN-00:10 | 12686.61 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:CORE_MID | 63.48 | 307.97 | 01-JAN-00:10 | 5543.17 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:CORE_MID | 63.48 | 307.97 | 01-JAN-00:10 | 5543.17 | 02-JAN-08:10 |
Electricity:Zone:CORE_TOP | 190.09 | 2689.12 | 01-JAN-00:10 | 12686.61 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:CORE_TOP | 63.48 | 307.97 | 01-JAN-00:10 | 5543.17 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:CORE_TOP | 63.48 | 307.97 | 01-JAN-00:10 | 5543.17 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_TOP_ZN_3 | 35.90 | 541.99 | 01-JAN-08:30 | 2570.09 | 11-OCT-07:10 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_3 | 9.22 | 40.03 | 01-JAN-08:30 | 1064.20 | 11-OCT-07:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_3 | 9.22 | 40.03 | 01-JAN-08:30 | 1064.20 | 11-OCT-07:10 |
Electricity:Zone:PERIMETER_TOP_ZN_2 | 22.72 | 343.10 | 01-JAN-07:50 | 1626.91 | 27-NOV-17:00 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_2 | 5.83 | 25.34 | 01-JAN-07:50 | 673.61 | 27-NOV-17:00 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_2 | 5.83 | 25.34 | 01-JAN-07:50 | 673.61 | 27-NOV-17:00 |
Electricity:Zone:PERIMETER_TOP_ZN_1 | 35.85 | 541.99 | 01-JAN-07:50 | 2565.78 | 11-OCT-07:10 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_1 | 9.16 | 40.03 | 01-JAN-07:50 | 1059.90 | 11-OCT-07:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_1 | 9.16 | 40.03 | 01-JAN-07:50 | 1059.90 | 11-OCT-07:10 |
Electricity:Zone:PERIMETER_TOP_ZN_4 | 22.72 | 343.10 | 01-JAN-08:40 | 1629.37 | 11-OCT-07:10 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_4 | 5.82 | 25.34 | 01-JAN-08:40 | 676.08 | 11-OCT-07:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_4 | 5.82 | 25.34 | 01-JAN-08:40 | 676.08 | 11-OCT-07:10 |
Electricity:Zone:PERIMETER_BOT_ZN_3 | 35.89 | 541.99 | 01-JAN-08:30 | 2565.56 | 11-OCT-07:10 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_3 | 9.20 | 40.03 | 01-JAN-08:30 | 1059.67 | 11-OCT-07:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_3 | 9.20 | 40.03 | 01-JAN-08:30 | 1059.67 | 11-OCT-07:10 |
Electricity:Zone:PERIMETER_BOT_ZN_2 | 22.72 | 343.10 | 01-JAN-07:50 | 1624.55 | 27-NOV-17:00 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_2 | 5.82 | 25.34 | 01-JAN-07:50 | 671.26 | 27-NOV-17:00 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_2 | 5.82 | 25.34 | 01-JAN-07:50 | 671.26 | 27-NOV-17:00 |
Electricity:Zone:PERIMETER_BOT_ZN_1 | 35.84 | 541.99 | 01-JAN-07:50 | 2561.00 | 11-OCT-07:10 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_1 | 9.16 | 40.03 | 01-JAN-07:50 | 1055.12 | 11-OCT-07:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_1 | 9.16 | 40.03 | 01-JAN-07:50 | 1055.12 | 11-OCT-07:10 |
Electricity:Zone:PERIMETER_BOT_ZN_4 | 22.71 | 343.10 | 01-JAN-08:40 | 1627.23 | 11-OCT-07:10 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_4 | 5.82 | 25.34 | 01-JAN-08:40 | 673.94 | 11-OCT-07:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_4 | 5.82 | 25.34 | 01-JAN-08:40 | 673.94 | 11-OCT-07:10 |
Electricity:Zone:PERIMETER_MID_ZN_3 | 35.90 | 541.99 | 01-JAN-08:30 | 2570.09 | 11-OCT-07:10 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_3 | 9.22 | 40.03 | 01-JAN-08:30 | 1064.19 | 11-OCT-07:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_3 | 9.22 | 40.03 | 01-JAN-08:30 | 1064.19 | 11-OCT-07:10 |
Electricity:Zone:PERIMETER_MID_ZN_2 | 22.72 | 343.10 | 01-JAN-07:50 | 1626.91 | 27-NOV-17:00 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_2 | 5.83 | 25.34 | 01-JAN-07:50 | 673.61 | 27-NOV-17:00 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_2 | 5.83 | 25.34 | 01-JAN-07:50 | 673.61 | 27-NOV-17:00 |
Electricity:Zone:PERIMETER_MID_ZN_1 | 35.85 | 541.99 | 01-JAN-07:50 | 2565.77 | 11-OCT-07:10 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_1 | 9.16 | 40.03 | 01-JAN-07:50 | 1059.89 | 11-OCT-07:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_1 | 9.16 | 40.03 | 01-JAN-07:50 | 1059.89 | 11-OCT-07:10 |
Electricity:Zone:PERIMETER_MID_ZN_4 | 22.72 | 343.10 | 01-JAN-08:40 | 1629.36 | 11-OCT-07:10 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_4 | 5.82 | 25.34 | 01-JAN-08:40 | 676.07 | 11-OCT-07:10 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_4 | 5.82 | 25.34 | 01-JAN-08:40 | 676.07 | 11-OCT-07:10 |
InteriorEquipment:Electricity | 762.04 | 14025.39 | 01-JAN-00:10 | 47562.27 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:CORE_BOTTOM | 247.34 | 4344.73 | 01-JAN-00:10 | 18520.31 | 02-JAN-08:10 |
InteriorEquipment:Electricity:SpaceType:GENERAL | 762.04 | 14025.39 | 01-JAN-00:10 | 47562.27 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity | 641.30 | 12061.80 | 01-JAN-00:10 | 36185.40 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_BOTTOM | 126.60 | 2381.15 | 01-JAN-00:10 | 7143.44 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL | 641.30 | 12061.80 | 01-JAN-00:10 | 36185.40 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:CORE_MID | 126.60 | 2381.15 | 01-JAN-00:10 | 7143.44 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_MID | 126.60 | 2381.15 | 01-JAN-00:10 | 7143.44 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:CORE_TOP | 126.60 | 2381.15 | 01-JAN-00:10 | 7143.44 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_TOP | 126.60 | 2381.15 | 01-JAN-00:10 | 7143.44 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_3 | 26.69 | 501.96 | 01-JAN-00:10 | 1505.89 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_3 | 26.69 | 501.96 | 01-JAN-00:10 | 1505.89 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_2 | 16.89 | 317.77 | 01-JAN-00:10 | 953.30 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_2 | 16.89 | 317.77 | 01-JAN-00:10 | 953.30 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_1 | 26.69 | 501.96 | 01-JAN-00:10 | 1505.88 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_1 | 26.69 | 501.96 | 01-JAN-00:10 | 1505.88 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_4 | 16.89 | 317.76 | 01-JAN-00:10 | 953.29 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_4 | 16.89 | 317.76 | 01-JAN-00:10 | 953.29 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_3 | 26.69 | 501.96 | 01-JAN-00:10 | 1505.89 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_3 | 26.69 | 501.96 | 01-JAN-00:10 | 1505.89 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_2 | 16.89 | 317.77 | 01-JAN-00:10 | 953.30 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_2 | 16.89 | 317.77 | 01-JAN-00:10 | 953.30 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_1 | 26.69 | 501.96 | 01-JAN-00:10 | 1505.88 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_1 | 26.69 | 501.96 | 01-JAN-00:10 | 1505.88 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_4 | 16.89 | 317.76 | 01-JAN-00:10 | 953.29 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_4 | 16.89 | 317.76 | 01-JAN-00:10 | 953.29 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_3 | 26.69 | 501.96 | 01-JAN-00:10 | 1505.89 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_3 | 26.69 | 501.96 | 01-JAN-00:10 | 1505.89 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_2 | 16.89 | 317.77 | 01-JAN-00:10 | 953.30 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_2 | 16.89 | 317.77 | 01-JAN-00:10 | 953.30 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_1 | 26.69 | 501.96 | 01-JAN-00:10 | 1505.88 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_1 | 26.69 | 501.96 | 01-JAN-00:10 | 1505.88 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_4 | 16.89 | 317.76 | 01-JAN-00:10 | 953.29 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_4 | 16.89 | 317.76 | 01-JAN-00:10 | 953.29 | 02-JAN-08:10 |
ElevatorLift:InteriorEquipment:Electricity | 120.10 | 1963.59 | 01-JAN-00:10 | 11290.62 | 02-JAN-08:10 |
ElevatorLift:InteriorEquipment:Electricity:Zone:CORE_BOTTOM | 120.10 | 1963.59 | 01-JAN-00:10 | 11290.62 | 02-JAN-08:10 |
ElevatorLift:InteriorEquipment:Electricity:SpaceType:GENERAL | 120.10 | 1963.59 | 01-JAN-00:10 | 11290.62 | 02-JAN-08:10 |
ElevatorLightsFan:InteriorEquipment:Electricity | 0.64 | 0.00 | 01-JAN-00:10 | 86.25 | 02-JAN-08:10 |
ElevatorLightsFan:InteriorEquipment:Electricity:Zone:CORE_BOTTOM | 0.64 | 0.00 | 01-JAN-00:10 | 86.25 | 02-JAN-08:10 |
ElevatorLightsFan:InteriorEquipment:Electricity:SpaceType:GENERAL | 0.64 | 0.00 | 01-JAN-00:10 | 86.25 | 02-JAN-08:10 |
Electricity:HVAC | 898.21 | 197.13 | 01-JAN-00:10 | 134709.00 | 12-JUN-14:10 |
ExteriorEquipment:Electricity | 12.98 | 197.13 | 01-JAN-00:10 | 926.67 | 11-OCT-07:20 |
Transformer:ExteriorEquipment:Electricity | 12.98 | 197.13 | 01-JAN-00:10 | 926.67 | 11-OCT-07:20 |
ElectricityPurchased:Facility | 2012.66 | 15539.06 | 29-MAY-17:20 | 200684.14 | 12-JUN-14:10 |
ElectricityPurchased:Plant | 2012.66 | 15539.06 | 29-MAY-17:20 | 200684.14 | 12-JUN-14:10 |
Cogeneration:ElectricityPurchased | 2012.66 | 15539.06 | 29-MAY-17:20 | 200684.14 | 12-JUN-14:10 |
General:Cogeneration:ElectricityPurchased | 2012.66 | 15539.06 | 29-MAY-17:20 | 200684.14 | 12-JUN-14:10 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 2012.66 | 15539.06 | 29-MAY-17:20 | 200684.14 | 12-JUN-14:10 |
ElectricityNet:Plant | 2012.66 | 15539.06 | 29-MAY-17:20 | 200684.14 | 12-JUN-14:10 |
Cogeneration:ElectricityNet | 2012.66 | 15539.06 | 29-MAY-17:20 | 200684.14 | 12-JUN-14:10 |
General:Cogeneration:ElectricityNet | 2012.66 | 15539.06 | 29-MAY-17:20 | 200684.14 | 12-JUN-14:10 |
Heating:Electricity | 3.90 | 0.00 | 01-JAN-00:10 | 60970.28 | 02-JAN-07:10 |
General:Heating:Electricity | 3.90 | 0.00 | 01-JAN-00:10 | 60970.28 | 02-JAN-07:10 |
Fans:Electricity | 154.00 | 0.00 | 01-JAN-00:10 | 26879.61 | 05-JUN-14:10 |
General:Fans:Electricity | 154.00 | 0.00 | 01-JAN-00:10 | 26879.61 | 05-JUN-14:10 |
ExteriorLights:Electricity | 71.88 | 0.00 | 01-JAN-07:20 | 5557.43 | 01-JAN-06:10 |
General:ExteriorLights:Electricity | 71.88 | 0.00 | 01-JAN-07:20 | 5557.43 | 01-JAN-06:10 |
Cooling:Electricity | 727.33 | 0.00 | 01-JAN-00:10 | 111751.03 | 12-JUN-15:30 |
General:Cooling:Electricity | 727.33 | 0.00 | 01-JAN-00:10 | 111751.03 | 12-JUN-15:30 |
Electricity:Plant | 0.02 | 0.00 | 01-JAN-00:10 | 0.73 | 02-JAN-08:10 |
Pumps:Electricity | 0.02 | 0.00 | 01-JAN-00:10 | 0.73 | 02-JAN-08:10 |
General:Pumps:Electricity | 0.02 | 0.00 | 01-JAN-00:10 | 0.73 | 02-JAN-08:10 |
WIRED_LTG_ELECTRICITY | 7.88 | 0.00 | 01-JAN-00:10 | 759.02 | 11-OCT-07:20 |
WIRED_INT_EQUIP | 641.94 | 12061.80 | 01-JAN-00:10 | 36271.65 | 02-JAN-08:10 |
Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
NaturalGas:Facility | 91.25 | 1156.00 | 14-APR-17:10 | 20932.15 | 03-JAN-06:10 |
NaturalGas:HVAC | 1.57 | 0.00 | 01-JAN-00:10 | 13926.47 | 03-JAN-07:00 |
Heating:NaturalGas | 1.57 | 0.00 | 01-JAN-00:10 | 13926.47 | 03-JAN-07:00 |
General:Heating:NaturalGas | 1.57 | 0.00 | 01-JAN-00:10 | 13926.47 | 03-JAN-07:00 |
NaturalGas:Plant | 89.69 | 1156.00 | 20-JAN-08:10 | 8968.08 | 17-JAN-12:10 |
WaterSystems:NaturalGas | 89.69 | 1156.00 | 20-JAN-08:10 | 8968.08 | 17-JAN-12:10 |
Water Heater:WaterSystems:NaturalGas | 89.69 | 1156.00 | 20-JAN-08:10 | 8968.08 | 17-JAN-12:10 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
Water:Plant | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
WaterSystems:Water | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
WaterUse:WaterSystems:Water | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
MainsWater:Facility | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
MainsWater:Plant | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
WaterSystems:MainsWater | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
WaterUse:WaterSystems:MainsWater | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
Water Heater:WaterSystems:Water | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:MainsWater | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
EnergyTransfer:Facility | 4459.10 | 0.00 | 01-JAN-00:10 | 506630.45 | 22-JUN-15:40 |
EnergyTransfer:Building | 1768.25 | 0.00 | 01-JAN-00:10 | 194500.69 | 12-JUN-15:50 |
EnergyTransfer:Zone:CORE_BOTTOM | 319.95 | 0.00 | 01-JAN-00:10 | 28422.17 | 05-SEP-08:00 |
Heating:EnergyTransfer | 7.23 | 0.00 | 01-JAN-00:10 | 49290.69 | 02-JAN-07:10 |
Heating:EnergyTransfer:Zone:CORE_BOTTOM | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer | 7.23 | 0.00 | 01-JAN-00:10 | 49290.69 | 02-JAN-07:10 |
General:Heating:EnergyTransfer:Zone:CORE_BOTTOM | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer | 1761.03 | 0.00 | 01-JAN-00:10 | 194500.69 | 12-JUN-15:50 |
Cooling:EnergyTransfer:Zone:CORE_BOTTOM | 319.95 | 0.00 | 01-JAN-00:10 | 28422.17 | 05-SEP-08:00 |
General:Cooling:EnergyTransfer | 1761.03 | 0.00 | 01-JAN-00:10 | 194500.69 | 12-JUN-15:50 |
General:Cooling:EnergyTransfer:Zone:CORE_BOTTOM | 319.95 | 0.00 | 01-JAN-00:10 | 28422.17 | 05-SEP-08:00 |
EnergyTransfer:Zone:TOPFLOOR_PLENUM | 86.80 | 0.00 | 01-JAN-00:10 | 16537.62 | 12-JUN-14:10 |
Heating:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 3.93 | 0.00 | 01-JAN-00:10 | 6623.83 | 02-JAN-06:10 |
General:Heating:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 3.93 | 0.00 | 01-JAN-00:10 | 6623.83 | 02-JAN-06:10 |
Cooling:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 82.87 | 0.00 | 01-JAN-00:10 | 16537.62 | 12-JUN-14:10 |
General:Cooling:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 82.87 | 0.00 | 01-JAN-00:10 | 16537.62 | 12-JUN-14:10 |
EnergyTransfer:Zone:MIDFLOOR_PLENUM | 44.98 | 0.00 | 01-JAN-00:10 | 6740.67 | 12-JUN-12:10 |
Heating:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 0.95 | 0.00 | 01-JAN-00:10 | 1967.72 | 02-JAN-14:10 |
General:Heating:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 0.95 | 0.00 | 01-JAN-00:10 | 1967.72 | 02-JAN-14:10 |
Cooling:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 44.04 | 0.00 | 01-JAN-00:10 | 6740.67 | 12-JUN-12:10 |
General:Cooling:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 44.04 | 0.00 | 01-JAN-00:10 | 6740.67 | 12-JUN-12:10 |
EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 51.21 | 0.00 | 01-JAN-00:10 | 6594.17 | 03-JUL-07:10 |
Heating:EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 0.48 | 0.00 | 01-JAN-00:10 | 1835.40 | 02-JAN-08:30 |
General:Heating:EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 0.48 | 0.00 | 01-JAN-00:10 | 1835.40 | 02-JAN-08:30 |
Cooling:EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 50.73 | 0.00 | 01-JAN-00:10 | 6594.17 | 03-JUL-07:10 |
General:Cooling:EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 50.73 | 0.00 | 01-JAN-00:10 | 6594.17 | 03-JUL-07:10 |
EnergyTransfer:Zone:CORE_MID | 224.90 | 0.00 | 01-JAN-00:10 | 20756.90 | 30-MAY-07:40 |
Heating:EnergyTransfer:Zone:CORE_MID | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer:Zone:CORE_MID | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:CORE_MID | 224.90 | 0.00 | 01-JAN-00:10 | 20756.90 | 30-MAY-07:40 |
General:Cooling:EnergyTransfer:Zone:CORE_MID | 224.90 | 0.00 | 01-JAN-00:10 | 20756.90 | 30-MAY-07:40 |
EnergyTransfer:Zone:CORE_TOP | 232.76 | 0.00 | 01-JAN-00:10 | 23801.03 | 12-JUN-14:00 |
Heating:EnergyTransfer:Zone:CORE_TOP | 0.04 | 0.00 | 01-JAN-00:10 | 9693.54 | 02-JAN-07:10 |
General:Heating:EnergyTransfer:Zone:CORE_TOP | 0.04 | 0.00 | 01-JAN-00:10 | 9693.54 | 02-JAN-07:10 |
Cooling:EnergyTransfer:Zone:CORE_TOP | 232.71 | 0.00 | 01-JAN-00:10 | 23801.03 | 12-JUN-14:00 |
General:Cooling:EnergyTransfer:Zone:CORE_TOP | 232.71 | 0.00 | 01-JAN-00:10 | 23801.03 | 12-JUN-14:00 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 69.56 | 0.00 | 01-JAN-00:10 | 9558.72 | 12-JUN-16:00 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 0.28 | 0.00 | 01-JAN-00:10 | 5443.13 | 02-JAN-06:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 0.28 | 0.00 | 01-JAN-00:10 | 5443.13 | 02-JAN-06:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 69.29 | 0.00 | 01-JAN-00:10 | 9558.72 | 12-JUN-16:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 69.29 | 0.00 | 01-JAN-00:10 | 9558.72 | 12-JUN-16:00 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 56.36 | 0.00 | 01-JAN-00:10 | 9273.87 | 12-JUN-09:40 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 0.12 | 0.00 | 01-JAN-00:10 | 3519.77 | 02-JAN-06:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 0.12 | 0.00 | 01-JAN-00:10 | 3519.77 | 02-JAN-06:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 56.24 | 0.00 | 01-JAN-00:10 | 9273.87 | 12-JUN-09:40 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 56.24 | 0.00 | 01-JAN-00:10 | 9273.87 | 12-JUN-09:40 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 90.64 | 0.00 | 01-JAN-00:10 | 12805.53 | 02-OCT-13:30 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 0.14 | 0.00 | 01-JAN-00:10 | 4854.03 | 02-JAN-07:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 0.14 | 0.00 | 01-JAN-00:10 | 4854.03 | 02-JAN-07:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 90.50 | 0.00 | 01-JAN-00:10 | 12805.53 | 02-OCT-13:30 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 90.50 | 0.00 | 01-JAN-00:10 | 12805.53 | 02-OCT-13:30 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 56.90 | 0.00 | 01-JAN-00:10 | 10030.39 | 08-JUN-16:00 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 0.17 | 0.00 | 01-JAN-00:10 | 3446.25 | 02-JAN-06:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 0.17 | 0.00 | 01-JAN-00:10 | 3446.25 | 02-JAN-06:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 56.72 | 0.00 | 01-JAN-00:10 | 10030.39 | 08-JUN-16:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 56.72 | 0.00 | 01-JAN-00:10 | 10030.39 | 08-JUN-16:00 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 66.57 | 0.00 | 01-JAN-00:10 | 8412.17 | 12-JUN-16:00 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 0.00 | 0.00 | 01-JAN-00:10 | 1507.31 | 02-JAN-07:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 0.00 | 0.00 | 01-JAN-00:10 | 1507.31 | 02-JAN-07:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 66.57 | 0.00 | 01-JAN-00:10 | 8412.17 | 12-JUN-16:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 66.57 | 0.00 | 01-JAN-00:10 | 8412.17 | 12-JUN-16:00 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 54.68 | 0.00 | 01-JAN-00:10 | 8049.40 | 12-JUN-09:40 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 0.00 | 0.00 | 01-JAN-00:10 | 726.22 | 02-JAN-07:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 0.00 | 0.00 | 01-JAN-00:10 | 726.22 | 02-JAN-07:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 54.67 | 0.00 | 01-JAN-00:10 | 8049.40 | 12-JUN-09:40 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 54.67 | 0.00 | 01-JAN-00:10 | 8049.40 | 12-JUN-09:40 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 103.08 | 0.00 | 01-JAN-00:10 | 15207.83 | 12-JUN-17:00 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 1.09 | 0.00 | 01-JAN-00:10 | 5672.28 | 03-JAN-07:50 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 1.09 | 0.00 | 01-JAN-00:10 | 5672.28 | 03-JAN-07:50 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 101.99 | 0.00 | 01-JAN-00:10 | 15207.83 | 12-JUN-17:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 101.99 | 0.00 | 01-JAN-00:10 | 15207.83 | 12-JUN-17:00 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 54.21 | 0.00 | 01-JAN-00:10 | 8364.13 | 12-JUN-16:00 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 0.00 | 0.00 | 01-JAN-00:10 | 703.12 | 02-JAN-07:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 0.00 | 0.00 | 01-JAN-00:10 | 703.12 | 02-JAN-07:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 54.21 | 0.00 | 01-JAN-00:10 | 8364.13 | 12-JUN-16:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 54.21 | 0.00 | 01-JAN-00:10 | 8364.13 | 12-JUN-16:00 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 64.77 | 0.00 | 01-JAN-00:10 | 8359.07 | 12-JUN-16:00 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 0.01 | 0.00 | 01-JAN-00:10 | 2187.18 | 02-JAN-07:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 0.01 | 0.00 | 01-JAN-00:10 | 2187.18 | 02-JAN-07:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 64.76 | 0.00 | 01-JAN-00:10 | 8359.07 | 12-JUN-16:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 64.76 | 0.00 | 01-JAN-00:10 | 8359.07 | 12-JUN-16:00 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 52.25 | 0.00 | 01-JAN-00:10 | 8415.66 | 03-MAY-09:00 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 0.01 | 0.00 | 01-JAN-00:10 | 1373.87 | 02-JAN-07:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 0.01 | 0.00 | 01-JAN-00:10 | 1373.87 | 02-JAN-07:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 52.24 | 0.00 | 01-JAN-00:10 | 8415.66 | 03-MAY-09:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 52.24 | 0.00 | 01-JAN-00:10 | 8415.66 | 03-MAY-09:00 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 85.70 | 0.00 | 01-JAN-00:10 | 11095.27 | 02-OCT-13:30 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 0.01 | 0.00 | 01-JAN-00:10 | 2078.18 | 02-JAN-07:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 0.01 | 0.00 | 01-JAN-00:10 | 2078.18 | 02-JAN-07:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 85.70 | 0.00 | 01-JAN-00:10 | 11095.27 | 02-OCT-13:30 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 85.70 | 0.00 | 01-JAN-00:10 | 11095.27 | 02-OCT-13:30 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 52.95 | 0.00 | 01-JAN-00:10 | 8939.64 | 08-JUN-16:00 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 0.01 | 0.00 | 01-JAN-00:10 | 1323.66 | 02-JAN-07:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 0.01 | 0.00 | 01-JAN-00:10 | 1323.66 | 02-JAN-07:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 52.94 | 0.00 | 01-JAN-00:10 | 8939.64 | 08-JUN-16:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 52.94 | 0.00 | 01-JAN-00:10 | 8939.64 | 08-JUN-16:00 |
PlantLoopHeatingDemand:Facility | 34.85 | 0.00 | 01-JAN-00:10 | 4900.43 | 18-JAN-12:10 |
PlantLoopHeatingDemand:Plant | 34.85 | 0.00 | 01-JAN-00:10 | 4900.43 | 18-JAN-12:10 |
WaterSystems:PlantLoopHeatingDemand | 34.85 | 0.00 | 01-JAN-00:10 | 4900.43 | 18-JAN-12:10 |
General:WaterSystems:PlantLoopHeatingDemand | 34.85 | 0.00 | 01-JAN-00:10 | 4900.43 | 18-JAN-12:10 |
EnergyTransfer:HVAC | 2655.99 | 0.00 | 01-JAN-00:10 | 331415.52 | 22-JUN-15:30 |
HeatingCoils:EnergyTransfer | 5.15 | 0.00 | 01-JAN-00:10 | 68343.44 | 02-JAN-07:10 |
CoolingCoils:EnergyTransfer | 2650.84 | 0.00 | 01-JAN-00:10 | 331415.52 | 22-JUN-15:30 |
EnergyTransfer:Plant | 34.85 | 0.00 | 01-JAN-00:10 | 4900.43 | 18-JAN-12:10 |
WaterSystems:EnergyTransfer | 34.85 | 0.00 | 01-JAN-00:10 | 4900.43 | 18-JAN-12:10 |
WaterUse:WaterSystems:EnergyTransfer | 34.85 | 0.00 | 01-JAN-00:10 | 4900.43 | 18-JAN-12:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
CORE_BOTTOM | 0.000 | 0.000 | 0.000 | -319.948 | 0.000 | 0.000 | 32.673 | 63.485 | 247.342 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -23.553 |
CORE_MID | 0.000 | 0.000 | 0.000 | -224.905 | 0.000 | 0.000 | 32.809 | 63.485 | 126.600 | 0.000 | 0.000 | 0.000 | 2.011 | 0.000 | 0.000 | 0.000 | 0.000 | -0.001 |
CORE_TOP | 0.000 | 0.000 | 0.042 | -232.715 | 0.000 | 0.000 | 33.120 | 63.485 | 126.600 | 0.000 | 0.000 | 0.000 | 9.468 | 0.000 | 0.000 | 0.000 | 0.000 | -0.003 |
PERIMETER_TOP_ZN_3 | 0.000 | 0.000 | 0.276 | -69.286 | 0.000 | 0.000 | 7.060 | 9.215 | 26.688 | 29.299 | 0.000 | 0.762 | 8.720 | 0.000 | -12.352 | 0.000 | -0.382 | -0.000 |
PERIMETER_TOP_ZN_2 | 0.000 | 0.000 | 0.115 | -56.240 | 0.000 | 0.000 | 4.426 | 5.828 | 16.895 | 34.327 | 0.000 | 0.500 | 2.254 | 0.000 | -7.835 | 0.000 | -0.269 | -0.001 |
PERIMETER_TOP_ZN_1 | 0.000 | 0.000 | 0.139 | -90.499 | 0.000 | 0.000 | 6.965 | 9.164 | 26.688 | 61.822 | 0.000 | 0.748 | 0.002 | 0.000 | -12.303 | 0.000 | -0.441 | -2.282 |
PERIMETER_TOP_ZN_4 | 0.000 | 0.000 | 0.174 | -56.723 | 0.000 | 0.000 | 4.476 | 5.822 | 16.895 | 34.712 | 0.000 | 0.504 | 2.743 | 0.000 | -8.336 | 0.000 | -0.266 | -0.001 |
PERIMETER_BOT_ZN_3 | 0.000 | 0.000 | 0.003 | -66.569 | 0.000 | 0.000 | 6.968 | 9.203 | 26.688 | 29.268 | 0.000 | 0.415 | 7.826 | 0.000 | -13.575 | 0.000 | -0.228 | -0.000 |
PERIMETER_BOT_ZN_2 | 0.000 | 0.000 | 0.001 | -54.675 | 0.000 | 0.000 | 4.380 | 5.822 | 16.895 | 34.214 | 0.000 | 0.269 | 1.977 | 0.000 | -8.721 | 0.000 | -0.162 | -0.000 |
PERIMETER_BOT_ZN_1 | 0.000 | 0.000 | 1.087 | -101.988 | 0.000 | 0.000 | 6.881 | 9.156 | 26.688 | 61.646 | 0.000 | 20.264 | 0.000 | 0.000 | -13.756 | 0.000 | -8.985 | -0.993 |
PERIMETER_BOT_ZN_4 | 0.000 | 0.000 | 0.001 | -54.205 | 0.000 | 0.000 | 4.401 | 5.815 | 16.895 | 34.636 | 0.000 | 0.268 | 1.692 | 0.000 | -9.340 | 0.000 | -0.162 | -0.000 |
PERIMETER_MID_ZN_3 | 0.000 | 0.000 | 0.014 | -64.757 | 0.000 | 0.000 | 6.977 | 9.215 | 26.688 | 29.301 | 0.000 | 0.638 | 5.700 | 0.000 | -13.421 | 0.000 | -0.355 | 0.000 |
PERIMETER_MID_ZN_2 | 0.000 | 0.000 | 0.008 | -52.241 | 0.000 | 0.000 | 3.245 | 5.828 | 16.895 | 34.306 | 0.000 | 0.420 | 0.200 | 0.000 | -8.415 | 0.000 | -0.246 | -0.000 |
PERIMETER_MID_ZN_1 | 0.000 | 0.000 | 0.006 | -85.697 | 0.000 | 0.000 | 6.917 | 9.164 | 26.688 | 61.864 | 0.000 | 0.626 | 0.001 | 0.000 | -13.196 | 0.000 | -0.398 | -5.973 |
PERIMETER_MID_ZN_4 | 0.000 | 0.000 | 0.010 | -52.943 | 0.000 | 0.000 | 4.423 | 5.822 | 16.895 | 34.717 | 0.000 | 0.419 | 0.000 | 0.000 | -9.019 | 0.000 | -0.246 | -0.079 |
TOPFLOOR_PLENUM | 3.930 | -82.867 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 1.004 | 78.528 | 0.000 | 0.000 | 0.000 | -0.595 | -0.001 |
MIDFLOOR_PLENUM | 0.947 | -44.035 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 1.003 | 42.708 | 0.000 | 0.000 | 0.000 | -0.622 | -0.000 |
FIRSTFLOOR_PLENUM | 0.475 | -50.733 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.777 | 49.998 | 0.000 | 0.000 | 0.000 | -0.517 | -0.000 |
Total Facility | 5.351 | -177.634 | 1.877 | -1583.389 | 0.000 | 0.000 | 165.721 | 280.507 | 762.041 | 480.112 | 0.000 | 28.615 | 213.827 | 0.000 | -130.270 | 0.000 | -13.876 | -32.887 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
CORE_BOTTOM | 10-APR-04:02 | 0.00 | 0.00 | 0.00 | -45579.90 | 0.00 | 0.00 | 0.00 | 615.87 | 5138.45 | 0.00 | 0.00 | 0.00 | 39825.58 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 10-APR-04:02 | 0.00 | 0.00 | 0.00 | -34531.55 | 0.00 | 0.00 | 0.00 | 615.87 | 3174.86 | 0.00 | 0.00 | 0.00 | 30740.81 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 10-OCT-04:02 | 0.00 | 0.00 | 0.00 | -38496.24 | 0.00 | 0.00 | 0.00 | 615.87 | 3174.86 | 0.00 | 0.00 | 0.00 | 34705.50 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 04-JUN-16:21 | 0.00 | 0.00 | 0.00 | -15626.56 | 0.00 | 0.00 | 23.84 | 40.03 | 501.96 | 3860.05 | 0.00 | 278.72 | 10921.96 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 29-MAY-09:22 | 0.00 | 0.00 | 0.00 | -12349.96 | 0.00 | 0.00 | 12.40 | 25.34 | 317.77 | 7117.06 | 0.00 | 347.61 | 4529.80 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 09-OCT-12:22 | 0.00 | 0.00 | 0.00 | -17383.05 | 0.00 | 0.00 | 22.16 | 40.03 | 501.96 | 9843.49 | 0.00 | 9.89 | 6965.53 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 28-MAY-16:31 | 0.00 | 0.00 | 0.00 | -14215.87 | 0.00 | 0.00 | 10.06 | 25.34 | 317.76 | 7700.12 | 0.00 | 397.53 | 5765.05 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 11-JUN-16:11 | 0.00 | 0.00 | 0.00 | -12438.74 | 0.00 | 0.00 | 26.66 | 40.03 | 501.96 | 4054.44 | 0.00 | 75.54 | 7740.12 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 11-JUN-09:32 | 0.00 | 0.00 | 0.00 | -10629.14 | 0.00 | 0.00 | 15.69 | 25.34 | 317.77 | 6700.04 | 0.00 | 29.95 | 3540.37 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 12-JUN-17:00 | 0.00 | 0.00 | 0.00 | -15208.87 | 0.00 | 0.00 | 133.52 | 400.23 | 836.60 | 3178.65 | 0.00 | 15975.32 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -5315.46 |
PERIMETER_BOT_ZN_4 | 01-OCT-16:02 | 0.00 | 0.00 | 0.00 | -11223.28 | 0.00 | 0.00 | 14.68 | 25.34 | 317.76 | 5987.11 | 0.00 | 20.53 | 4857.87 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 04-JUN-14:32 | 0.00 | 0.00 | 0.00 | -12953.03 | 0.00 | 0.00 | 26.72 | 40.03 | 501.96 | 3620.33 | 0.00 | 259.92 | 8504.06 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 30-APR-08:52 | 0.00 | 0.00 | 0.00 | -11497.05 | 0.00 | 0.00 | 14.76 | 25.34 | 317.77 | 7825.14 | 0.00 | 1.71 | 3312.33 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 12-NOV-13:12 | 0.00 | 0.00 | 0.00 | -14515.16 | 0.00 | 0.00 | 23.46 | 40.03 | 501.96 | 10247.06 | 0.00 | 0.00 | 3713.30 | 0.00 | -0.00 | 0.00 | -10.65 | 0.00 |
PERIMETER_MID_ZN_4 | 11-JUN-16:11 | 0.00 | 0.00 | 0.00 | -12084.37 | 0.00 | 0.00 | 12.39 | 25.34 | 317.76 | 7584.97 | 0.00 | 72.64 | 4071.28 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 12-JUN-12:09 | 0.00 | -16588.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 198.59 | 16390.38 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 12-JUN-06:15 | 0.00 | -8700.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 79.37 | 8621.20 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 30-MAY-12:09 | 0.00 | -8686.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 88.08 | 8598.31 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 02-MAY-04:02 | 0.00 | 11124.61 | 0.00 | -225565.03 | 0.00 | 0.00 | 0.00 | 3119.77 | 18045.99 | 0.00 | 0.00 | 379.54 | 193583.55 | 0.00 | -688.43 | 0.00 | 0.00 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
CORE_BOTTOM | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 05-JAN-07:01 | 0.00 | 0.00 | 19992.51 | 0.00 | 0.00 | 0.00 | 890.34 | 1847.70 | 3174.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -25905.42 |
PERIMETER_TOP_ZN_3 | 02-JAN-06:01 | 0.00 | 0.00 | 9062.65 | 0.00 | 0.00 | 0.00 | 106.58 | 129.83 | 669.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1720.80 | 0.00 | 0.00 | -8247.55 |
PERIMETER_TOP_ZN_2 | 02-JAN-06:01 | 0.00 | 0.00 | 5771.24 | 0.00 | 0.00 | 0.00 | 67.48 | 82.19 | 423.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1147.45 | 0.00 | 0.00 | -5197.15 |
PERIMETER_TOP_ZN_1 | 02-JAN-06:01 | 0.00 | 0.00 | 8832.25 | 0.00 | 0.00 | 0.00 | 105.17 | 129.83 | 669.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1770.07 | 0.00 | 0.00 | -7966.46 |
PERIMETER_TOP_ZN_4 | 02-JAN-06:01 | 0.00 | 0.00 | 5625.83 | 0.00 | 0.00 | 0.00 | 67.31 | 82.19 | 423.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1153.61 | 0.00 | 0.00 | -5045.40 |
PERIMETER_BOT_ZN_3 | 02-JAN-07:03 | 0.00 | 0.00 | 4803.88 | 0.00 | 0.00 | 0.00 | 192.39 | 389.51 | 669.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2048.07 | 0.00 | 0.00 | -4007.00 |
PERIMETER_BOT_ZN_2 | 03-JAN-07:01 | 0.00 | 0.00 | 2627.74 | 0.00 | 0.00 | 0.00 | 120.07 | 246.59 | 423.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1525.43 | 0.00 | -7.11 | -1885.55 |
PERIMETER_BOT_ZN_1 | 03-JAN-07:10 | 0.00 | 0.00 | 5803.40 | 0.00 | 0.00 | 0.00 | 193.30 | 389.51 | 669.28 | 0.00 | 0.00 | 0.00 | 9924.94 | 0.00 | -2314.79 | 0.00 | -14665.65 | 0.00 |
PERIMETER_BOT_ZN_4 | 03-JAN-07:01 | 0.00 | 0.00 | 2655.19 | 0.00 | 0.00 | 0.00 | 120.03 | 246.58 | 423.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1541.68 | 0.00 | -7.11 | -1896.70 |
PERIMETER_MID_ZN_3 | 23-JAN-07:01 | 0.00 | 0.00 | 5670.55 | 0.00 | 0.00 | 0.00 | 188.74 | 389.51 | 669.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2076.71 | 0.00 | 0.00 | -4841.39 |
PERIMETER_MID_ZN_2 | 09-JAN-07:01 | 0.00 | 0.00 | 3787.97 | 0.00 | 0.00 | 0.00 | 119.52 | 246.59 | 423.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1361.14 | 0.00 | -5.61 | -3211.01 |
PERIMETER_MID_ZN_1 | 04-JAN-07:01 | 0.00 | 0.00 | 5651.88 | 0.00 | 0.00 | 0.00 | 188.81 | 389.51 | 669.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2277.65 | 0.00 | 0.00 | -4621.83 |
PERIMETER_MID_ZN_4 | 06-JAN-07:01 | 0.00 | 0.00 | 3812.53 | 0.00 | 0.00 | 0.00 | 119.50 | 246.58 | 423.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1493.96 | 0.00 | 0.00 | -3108.33 |
TOPFLOOR_PLENUM | 02-JAN-07:03 | 8891.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -8891.06 |
MIDFLOOR_PLENUM | 24-DEC-13:43 | 3962.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38.76 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -4001.41 |
FIRSTFLOOR_PLENUM | 17-JAN-06:03 | 6164.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -6164.17 |
Total Facility | 02-JAN-07:03 | -3496.36 | 12214.84 | 75617.38 | -12214.84 | 0.00 | 0.00 | 4467.33 | 9359.67 | 21853.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -19711.52 | 0.00 | -15525.97 | -72563.80 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PACU_VAV_BOT | 5.6470 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 5.3076 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
PACU_VAV_MID | 5.0525 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 4.6757 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
PACU_VAV_TOP | 5.8119 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 5.7097 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PACU_VAV_BOT | 2.8235 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 1.3707 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
PACU_VAV_MID | 2.5263 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 1.3491 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
PACU_VAV_TOP | 2.9060 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 1.4684 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
CORE_BOTTOM | PACU_VAV_BOT | 0.000000 | 52.9387 | 0.000432 | 983.54 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
CORE_MID | PACU_VAV_MID | 0.000000 | 52.9387 | 0.000432 | 983.54 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
CORE_TOP | PACU_VAV_TOP | 0.000000 | 52.9387 | 0.000432 | 983.54 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP | 0.000000 | 7.0652 | 0.000432 | 131.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP | 0.000000 | 7.0647 | 0.000432 | 131.25 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT | 0.000000 | 7.0652 | 0.000432 | 131.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT | 0.000000 | 7.0647 | 0.000432 | 131.25 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_3 | PACU_VAV_MID | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_2 | PACU_VAV_MID | 0.000000 | 7.0652 | 0.000432 | 131.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_1 | PACU_VAV_MID | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_4 | PACU_VAV_MID | 0.000000 | 7.0647 | 0.000432 | 131.25 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PACU_VAV_BOT | 0.00 | 0.000432 | 1660.7286 | 0.0000 | 0.0000 | 0.0000 | |
PACU_VAV_MID | 0.00 | 0.000432 | 1660.7286 | 0.0000 | 0.0000 | 0.0000 | |
PACU_VAV_TOP | 0.00 | 0.000432 | 1660.7286 | 0.0000 | 0.0000 | 0.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
CORE_BOTTOM | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.9360 | 2.9360 | 0.7927 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_MID | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.2088 | 2.2088 | 0.7664 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_TOP | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.5084 | 2.5084 | 0.8077 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.9141 | 0.9141 | 0.1828 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.6910 | 0.6910 | 0.1382 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.9292 | 0.9292 | 0.1858 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7692 | 0.7692 | 0.1538 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7402 | 0.7402 | 0.1673 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.5965 | 0.5965 | 0.1193 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7536 | 0.7536 | 0.1673 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.6207 | 0.6207 | 0.1241 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_3 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7667 | 0.7667 | 0.1618 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_2 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.6295 | 0.6295 | 0.1259 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_1 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7824 | 0.7824 | 0.1620 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_4 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.6651 | 0.6651 | 0.1330 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PACU_VAV_BOT | 5.6470 | 5.3076 | 5.6470 | 1.3707 | 0.0000 | 1.0000 |
PACU_VAV_MID | 5.0525 | 4.6757 | 5.0525 | 1.3491 | 0.0000 | 1.0000 |
PACU_VAV_TOP | 5.8119 | 5.7097 | 5.8119 | 1.4684 | 0.0000 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
CORE_BOTTOM | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.4680 | 1.4680 | 0.7927 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_MID | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.1044 | 1.1044 | 0.7664 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_TOP | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.2542 | 1.2542 | 0.8077 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4571 | 0.4571 | 0.1828 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3455 | 0.3455 | 0.1382 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4646 | 0.4646 | 0.1858 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3846 | 0.3846 | 0.1538 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3701 | 0.3701 | 0.1673 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2982 | 0.2982 | 0.1193 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3768 | 0.3768 | 0.1673 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3104 | 0.3104 | 0.1241 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_3 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3833 | 0.3833 | 0.1618 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_2 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3148 | 0.3148 | 0.1259 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_1 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3912 | 0.3912 | 0.1620 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_4 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3326 | 0.3326 | 0.1330 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PACU_VAV_BOT | 2.8235 | 1.3707 | 1.3707 | 1.3707 | 0.0000 | 1.0000 |
PACU_VAV_MID | 2.5263 | 1.3491 | 1.3491 | 1.3491 | 0.0000 | 1.0000 |
PACU_VAV_TOP | 2.9060 | 1.4684 | 1.4684 | 1.4684 | 0.0000 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** New Delhi-Safdarjung AP Delhi IND IWEC2 WMO#=421820 |
Total gross floor area [m2] | 4982.19 |
Principal Heating Source | Electricity |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
CORE_BOTTOM | 983.54 | 983.54 | 0.00 | 113.98 |
CORE_MID | 983.54 | 983.54 | 0.00 | 113.98 |
CORE_TOP | 983.54 | 983.54 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_3 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_2 | 131.26 | 131.26 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_1 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_4 | 131.25 | 131.25 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_3 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_2 | 131.26 | 131.26 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_1 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_4 | 131.25 | 131.25 | 0.00 | 113.98 |
PERIMETER_MID_ZN_3 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_MID_ZN_2 | 131.26 | 131.26 | 0.00 | 96.54 |
PERIMETER_MID_ZN_1 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_MID_ZN_4 | 131.25 | 131.25 | 0.00 | 113.98 |
TOPFLOOR_PLENUM | 1660.73 | 1660.73 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 1660.73 | 1660.73 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 1660.73 | 1660.73 | 0.00 | 0.00 |
Totals | 4982.19 | 4982.19 | 0.00 |
Data | |
Number of hours heating loads not met | 41.50 |
Number of hours cooling loads not met | 579.83 |
Number of hours not met | 621.33 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- General | 3.90 | 60970.28 | 1.57 | 13926.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- General | 727.33 | 111751.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 280.51 | 27011.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 71.88 | 5557.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 641.30 | 36185.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- ElevatorLift | 120.10 | 11290.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- ElevatorLightsFan | 0.64 | 86.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Transformer | 12.98 | 926.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 154.00 | 26879.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- General | 0.02 | 0.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 0.00 | 0.00 | 89.69 | 8968.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 762.04 | 2012.66 |
Natural Gas | 0.00 | 91.25 |
Additional | 0.00 | 0.00 |
Total | 762.04 | 2103.91 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 56.30 |
Space Heating | 0.78 |
Space Cooling | 145.99 |
Fans (All) | 30.91 |
Service Water Heating | 0.00 |
Receptacle Equipment | 152.95 |
Miscellaneous (All) | 403.97 |
Subtotal | 403.97 |
Natural Gas [MJ/m2] | |
Space Heating | 0.31 |
Service Water Heating | 18.00 |
Miscellaneous (All) | 18.32 |
Subtotal | 18.32 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 13.33 |
Space Heating | 0.26 |
Space Cooling | 34.57 |
Fans (All) | 7.32 |
Service Water Heating | 4.26 |
Receptacle Equipment | 36.22 |
Miscellaneous | 4.03 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 4472. | 4472. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_C_2016 | 6752. | 8760. |
ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 6828. | 8760. |
ALWAYS_OFF | 0. | 0. |
LTG_SCH_OFFICE | 2429. | 8760. |
BLDG_EQUIP_SCH | 4487. | 8760. |
BLDG_OCC_SCH | 2528. | 5992. |
BLDG_OCC_SCH_W_SB | 1878. | 5056. |
BLDG_OCC_SCH_WO_SB | 2545. | 5992. |
BLDG_ELEVATORS | 2070. | 8760. |
ELEV_LIGHT_FAN_SCH_24_7 | 8760. | 8760. |
ELEV_LIGHT_FAN_SCH_ADD_DF | 1470. | 4212. |
BLDG_SWH_SCH | 1441. | 5992. |
WORK_EFF_SCH | 0. | 0. |
FAN_SCH | 8760. | 8760. |
REHEATCOILAVAILSCHED | 8760. | 8760. |
COOLINGCOILAVAILSCHED | 8760. | 8760. |
MINOA_MOTORIZEDDAMPER_SCHED | 4472. | 4472. |
MINOA_SCHED | 8760. | 8760. |
CORE_BOTTOM SUB CAT LATENT FRACT SCHED | 438. | 8760. |
CORE_BOTTOM SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
CORE_MID SUB CAT LATENT FRACT SCHED | 438. | 8760. |
CORE_MID SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
CORE_TOP SUB CAT LATENT FRACT SCHED | 438. | 8760. |
CORE_TOP SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_TOP_ZN_3 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_TOP_ZN_3 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_TOP_ZN_2 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_TOP_ZN_2 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_TOP_ZN_1 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_TOP_ZN_1 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_TOP_ZN_4 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_TOP_ZN_4 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_BOT_ZN_3 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_BOT_ZN_3 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_BOT_ZN_2 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_BOT_ZN_2 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_BOT_ZN_1 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_BOT_ZN_1 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_BOT_ZN_4 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_BOT_ZN_4 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_MID_ZN_3 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_MID_ZN_3 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_MID_ZN_2 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_MID_ZN_2 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_MID_ZN_1 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_MID_ZN_1 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_MID_ZN_4 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_MID_ZN_4 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
INFIL_SCH_PNNL | 5172. | 8760. |
INFIL_DOOR_OPENING_SCH | 1154. | 3380. |
PERIMETER_MID_ZN_2_OA_MULT | 7824. | 7824. |
PERIMETER_MID_ZN_2_MDP_SCH | 1574. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
HTGSETP_SCH_YES_OPTIMUM | CORE_BOTTOM DUAL SP CONTROL | January | 21.00 | 365 | 15.60 | 365 |
CLGSETP_SCH_YES_OPTIMUM | CORE_BOTTOM DUAL SP CONTROL | July | 24.00 | 365 | 26.70 | 365 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
Heat Index HoursSafe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
CORE_BOTTOM | 8180.50 | 579.50 | 0.00 | 0.00 | 0.00 |
CORE_MID | 8700.17 | 59.83 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 8676.50 | 83.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 8111.33 | 648.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 8048.17 | 711.83 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 8015.17 | 744.83 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 7957.67 | 802.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 8214.50 | 545.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 8000.33 | 759.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 7866.50 | 893.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 7871.50 | 888.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 8118.50 | 641.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 8047.83 | 712.17 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 7995.33 | 764.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 7914.00 | 846.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 8122.00 | 638.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 8561.83 | 198.17 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 8667.50 | 92.50 | 0.00 | 0.00 | 0.00 |
Min | 7866.50 | 59.83 | 0.00 | 0.00 | 0.00 |
Max | 8700.17 | 893.50 | 0.00 | 0.00 | 0.00 |
Average | 8170.52 | 589.48 | 0.00 | 0.00 | 0.00 |
Sum | 147069.33 | 10610.67 | 0.00 | 0.00 | 0.00 |
Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
CORE_BOTTOM | 128174.00 | 130.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 128286.33 | 17.67 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 128273.33 | 30.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 24598.17 | 310.83 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 10134.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 128286.33 | 310.83 | 0.00 | 0.00 | 0.00 |
Average | 34116.16 | 27.18 | 0.00 | 0.00 | 0.00 |
Sum | 614090.83 | 489.17 | 0.00 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
CORE_BOTTOM | 7246.67 | 1513.33 | 0.00 | 0.00 | 0.00 |
CORE_MID | 7390.00 | 1370.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 7402.67 | 1357.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 7046.33 | 1713.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 7029.33 | 1730.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 6985.50 | 1774.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 7035.00 | 1725.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 7079.83 | 1680.17 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 6980.33 | 1779.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 6224.33 | 2535.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 6953.67 | 1806.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 6982.00 | 1778.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 6966.50 | 1793.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 6904.33 | 1855.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 6946.33 | 1813.67 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 5187.17 | 3572.83 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 6152.33 | 2607.67 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 6622.83 | 2137.17 | 0.00 | 0.00 | 0.00 |
Min | 5187.17 | 1357.33 | 0.00 | 0.00 | 0.00 |
Max | 7402.67 | 3572.83 | 0.00 | 0.00 | 0.00 |
Average | 6840.84 | 1919.16 | 0.00 | 0.00 | 0.00 |
Sum | 123135.17 | 34544.83 | 0.00 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
CORE_BOTTOM | 127438.00 | 866.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 127607.17 | 696.83 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 127530.17 | 773.83 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 24838.83 | 70.17 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 14015.17 | 0.83 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 24839.67 | 69.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 24839.83 | 69.17 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 20719.67 | 4189.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 24826.67 | 82.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 10133.33 | 0.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 24826.67 | 82.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 14015.67 | 0.33 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 127607.17 | 4189.33 | 0.00 | 0.00 | 0.00 |
Average | 33759.94 | 383.40 | 0.00 | 0.00 | 0.00 |
Sum | 607678.83 | 6901.17 | 0.00 | 0.00 | 0.00 |
SET ≤ 12.2°C Hours (°C) | SET ≤ 12.2°C OccupantHours (°C) | Longest SET ≤ 12.2°C Duration [hr] | Start Time of the Longest SET ≤ 12.2°C Duration | |
None |
SET > 30°C Hours (°C) | SET > 30°C OccupantHours (°C) | Longest SET > 30°C Duration [hr] | Start Time of the Longest SET > 30°C Duration | |
None |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
CO2 Level HoursSafe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:14
Illuminance Level HoursA Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
CORE_BOTTOM | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_3 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_2 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_1 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_4 | 0.00 | 0.00 | 8760.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 0.00 | 0.00 | 8760.00 | 0.00 |
Average | 0.00 | 0.00 | 5840.00 | 0.00 |
Sum | 0.00 | 0.00 | 105120.00 | 0.00 |
A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
CORE_BOTTOM | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 0.00 | 0.00 | 14016.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 0.00 | 0.00 | 14016.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 0.00 | 0.00 | 14016.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 0.00 | 0.00 | 14016.00 | 0.00 |
PERIMETER_MID_ZN_3 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_MID_ZN_2 | 0.00 | 0.00 | 10134.00 | 0.00 |
PERIMETER_MID_ZN_1 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_MID_ZN_4 | 0.00 | 0.00 | 14016.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 0.00 | 0.00 | 24909.00 | 0.00 |
Average | 0.00 | 0.00 | 12759.33 | 0.00 |
Sum | 0.00 | 0.00 | 229668.00 | 0.00 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Environment
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 13.392 |
February | 16.974 |
March | 22.368 |
April | 29.134 |
May | 32.978 |
June | 33.595 |
July | 31.671 |
August | 30.033 |
September | 28.750 |
October | 25.087 |
November | 19.629 |
December | 14.516 |
Annual Sum or Average | 24.876 |
Minimum of Months | 13.392 |
Maximum of Months | 33.595 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Environment
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 13.392 |
February | 16.974 |
March | 22.368 |
April | 29.134 |
May | 32.978 |
June | 33.595 |
July | 31.671 |
August | 30.033 |
September | 28.750 |
October | 25.087 |
November | 19.629 |
December | 14.516 |
Annual Sum or Average | 24.876 |
Minimum of Months | 13.392 |
Maximum of Months | 33.595 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2018
For: Environment
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 13.392 |
February | 16.974 |
March | 22.368 |
April | 29.134 |
May | 32.978 |
June | 33.595 |
July | 31.671 |
August | 30.033 |
September | 28.750 |
October | 25.087 |
November | 19.629 |
December | 14.516 |
Annual Sum or Average | 24.876 |
Minimum of Months | 13.392 |
Maximum of Months | 33.595 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Environment
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 13.392 |
February | 16.974 |
March | 22.368 |
April | 29.134 |
May | 32.978 |
June | 33.595 |
July | 31.671 |
August | 30.033 |
September | 28.750 |
October | 25.087 |
November | 19.629 |
December | 14.516 |
Annual Sum or Average | 24.876 |
Minimum of Months | 13.392 |
Maximum of Months | 33.595 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME OFFICEMEDIUM
For: Environment
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 13.392 |
February | 16.974 |
March | 22.368 |
April | 29.134 |
May | 32.978 |
June | 33.595 |
July | 31.671 |
August | 30.033 |
September | 28.750 |
October | 25.087 |
November | 19.629 |
December | 14.516 |
Annual Sum or Average | 24.876 |
Minimum of Months | 13.392 |
Maximum of Months | 33.595 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Environment
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 13.392 |
February | 16.974 |
March | 22.368 |
April | 29.134 |
May | 32.978 |
June | 33.595 |
July | 31.671 |
August | 30.033 |
September | 28.750 |
October | 25.087 |
November | 19.629 |
December | 14.516 |
Annual Sum or Average | 24.876 |
Minimum of Months | 13.392 |
Maximum of Months | 33.595 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Environment
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 13.392 |
February | 16.974 |
March | 22.368 |
April | 29.134 |
May | 32.978 |
June | 33.595 |
July | 31.671 |
August | 30.033 |
September | 28.750 |
October | 25.087 |
November | 19.629 |
December | 14.516 |
Annual Sum or Average | 24.876 |
Minimum of Months | 13.392 |
Maximum of Months | 33.595 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 1B
For: Environment
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 13.392 |
February | 16.974 |
March | 22.368 |
April | 29.134 |
May | 32.978 |
June | 33.595 |
July | 31.671 |
August | 30.033 |
September | 28.750 |
October | 25.087 |
November | 19.629 |
December | 14.516 |
Annual Sum or Average | 24.876 |
Minimum of Months | 13.392 |
Maximum of Months | 33.595 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY IND_DELHI_NEWDELHI
For: Environment
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 13.392 |
February | 16.974 |
March | 22.368 |
April | 29.134 |
May | 32.978 |
June | 33.595 |
July | 31.671 |
August | 30.033 |
September | 28.750 |
October | 25.087 |
November | 19.629 |
December | 14.516 |
Annual Sum or Average | 24.876 |
Minimum of Months | 13.392 |
Maximum of Months | 33.595 |
Report: ZoneCoolingSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.189137E+11 | 39757.12 | 27-JAN-06:03 | 11.07 | 9.85 | 0.199002E+10 | 2606.63 | 13-JAN-14:09 | 11.07 | 9.85 |
February | 0.198654E+11 | 41850.32 | 15-FEB-06:03 | 13.77 | 12.26 | 0.180774E+10 | 2606.65 | 07-FEB-10:00 | 13.77 | 12.26 |
March | 0.267830E+11 | 45373.12 | 13-MAR-04:02 | 20.88 | 16.38 | 0.215952E+10 | 2606.67 | 16-MAR-09:00 | 19.90 | 15.14 |
April | 0.275599E+11 | 45576.39 | 10-APR-04:02 | 18.53 | 13.30 | 0.191840E+10 | 2606.67 | 04-APR-09:09 | 18.53 | 13.30 |
May | 0.312891E+11 | 43986.18 | 25-MAY-04:03 | 26.00 | 23.62 | 0.207770E+10 | 2606.74 | 22-MAY-13:09 | 26.00 | 23.62 |
June | 0.309617E+11 | 43666.51 | 28-JUN-04:03 | 26.40 | 25.32 | 0.207088E+10 | 2606.73 | 20-JUN-13:09 | 26.40 | 25.32 |
July | 0.302873E+11 | 43607.28 | 19-JUL-04:03 | 24.72 | 24.59 | 0.192483E+10 | 2606.64 | 19-JUL-13:09 | 33.12 | 27.03 |
August | 0.315280E+11 | 43018.99 | 24-AUG-04:03 | 25.48 | 24.97 | 0.216082E+10 | 2606.64 | 21-AUG-13:30 | 25.48 | 24.97 |
September | 0.285838E+11 | 43153.47 | 07-SEP-04:03 | 24.78 | 23.91 | 0.191948E+10 | 2606.65 | 11-SEP-13:09 | 31.10 | 27.02 |
October | 0.284983E+11 | 44118.70 | 17-OCT-04:03 | 19.88 | 16.21 | 0.199529E+10 | 2606.67 | 31-OCT-09:09 | 21.83 | 17.04 |
November | 0.248991E+11 | 45116.87 | 13-NOV-05:02 | 14.83 | 12.40 | 0.197430E+10 | 2606.68 | 06-NOV-10:09 | 14.83 | 12.40 |
December | 0.207767E+11 | 42023.40 | 11-DEC-06:02 | 9.72 | 9.26 | 0.192200E+10 | 2606.65 | 27-DEC-10:50 | 18.92 | 13.38 |
Annual Sum or Average | 0.319946E+12 | 0.239210E+11 | ||||||||
Minimum of Months | 0.189137E+11 | 39757.12 | 9.72 | 9.26 | 0.180774E+10 | 2606.63 | 11.07 | 9.85 | ||
Maximum of Months | 0.315280E+11 | 45576.39 | 26.40 | 25.32 | 0.216082E+10 | 2606.74 | 33.12 | 27.03 |
Report: ZoneCoolingSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.130211E+10 | 4281.86 | 12-JAN-15:00 | 23.60 | 14.20 | 0.00 | 0.00 | 01-JAN-00:10 | 23.60 | 14.20 |
February | 0.243017E+10 | 8117.97 | 22-FEB-14:50 | 27.08 | 16.22 | 0.00 | 0.00 | 01-FEB-00:10 | 27.08 | 16.22 |
March | 0.586341E+10 | 12331.32 | 28-MAR-15:40 | 35.53 | 18.66 | 0.00 | 0.00 | 01-MAR-00:10 | 35.53 | 18.66 |
April | 0.974288E+10 | 14566.74 | 26-APR-15:00 | 39.30 | 22.03 | 0.00 | 0.00 | 01-APR-00:10 | 39.30 | 22.03 |
May | 0.124715E+11 | 16305.12 | 01-MAY-14:30 | 44.00 | 22.05 | 0.00 | 0.00 | 01-MAY-00:10 | 44.00 | 22.05 |
June | 0.123059E+11 | 16588.61 | 12-JUN-12:09 | 42.55 | 22.27 | 0.00 | 0.00 | 01-JUN-00:10 | 42.55 | 22.27 |
July | 0.100189E+11 | 15040.54 | 10-JUL-13:50 | 39.20 | 26.60 | 0.00 | 0.00 | 01-JUL-00:10 | 39.20 | 26.60 |
August | 0.922508E+10 | 13608.43 | 07-AUG-14:40 | 37.27 | 26.48 | 0.00 | 0.00 | 01-AUG-00:10 | 37.27 | 26.48 |
September | 0.744672E+10 | 12283.99 | 26-SEP-14:50 | 36.03 | 22.73 | 0.00 | 0.00 | 01-SEP-00:10 | 36.03 | 22.73 |
October | 0.666596E+10 | 12379.28 | 02-OCT-14:00 | 36.40 | 21.05 | 0.00 | 0.00 | 01-OCT-00:10 | 36.40 | 21.05 |
November | 0.384897E+10 | 8619.79 | 09-NOV-14:30 | 29.30 | 17.79 | 0.00 | 0.00 | 01-NOV-00:10 | 29.30 | 17.79 |
December | 0.154546E+10 | 5470.88 | 01-DEC-14:30 | 23.45 | 13.21 | 0.00 | 0.00 | 01-DEC-00:10 | 23.45 | 13.21 |
Annual Sum or Average | 0.828671E+11 | 0.00 | ||||||||
Minimum of Months | 0.130211E+10 | 4281.86 | 23.45 | 13.21 | 0.00 | 0.00 | 23.45 | 13.21 | ||
Maximum of Months | 0.124715E+11 | 16588.61 | 44.00 | 26.60 | 0.00 | 0.00 | 44.00 | 26.60 |
Report: ZoneCoolingSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.396779E+09 | 1859.61 | 04-JAN-07:01 | 5.50 | 4.96 | 0.00 | 0.00 | 01-JAN-00:10 | 5.50 | 4.96 |
February | 0.104314E+10 | 2712.18 | 22-FEB-15:40 | 26.70 | 16.04 | 0.00 | 0.00 | 01-FEB-00:10 | 26.70 | 16.04 |
March | 0.302396E+10 | 4904.22 | 13-MAR-16:00 | 32.50 | 18.65 | 0.00 | 0.00 | 01-MAR-00:10 | 32.50 | 18.65 |
April | 0.492402E+10 | 5963.70 | 17-APR-15:10 | 34.65 | 21.60 | 0.00 | 0.00 | 01-APR-00:10 | 34.65 | 21.60 |
May | 0.638170E+10 | 6712.80 | 30-MAY-11:03 | 36.62 | 23.44 | 0.00 | 0.00 | 01-MAY-00:10 | 36.62 | 23.44 |
June | 0.617327E+10 | 8701.63 | 12-JUN-06:15 | 35.03 | 19.50 | 0.00 | 0.00 | 01-JUN-00:10 | 35.03 | 19.50 |
July | 0.563037E+10 | 6660.65 | 05-JUL-12:03 | 37.65 | 25.58 | 0.00 | 0.00 | 01-JUL-00:10 | 37.65 | 25.58 |
August | 0.545925E+10 | 6891.09 | 14-AUG-06:15 | 28.60 | 26.29 | 0.00 | 0.00 | 01-AUG-00:10 | 28.60 | 26.29 |
September | 0.457397E+10 | 6663.31 | 05-SEP-06:15 | 26.23 | 25.18 | 0.00 | 0.00 | 01-SEP-00:10 | 26.23 | 25.18 |
October | 0.383087E+10 | 5604.12 | 02-OCT-15:50 | 35.98 | 21.22 | 0.00 | 0.00 | 01-OCT-00:10 | 35.98 | 21.22 |
November | 0.199188E+10 | 3589.56 | 13-NOV-16:00 | 27.60 | 16.57 | 0.00 | 0.00 | 01-NOV-00:10 | 27.60 | 16.57 |
December | 0.606031E+09 | 1713.44 | 01-DEC-15:30 | 22.85 | 13.56 | 0.00 | 0.00 | 01-DEC-00:10 | 22.85 | 13.56 |
Annual Sum or Average | 0.440352E+11 | 0.00 | ||||||||
Minimum of Months | 0.396779E+09 | 1713.44 | 5.50 | 4.96 | 0.00 | 0.00 | 5.50 | 4.96 | ||
Maximum of Months | 0.638170E+10 | 8701.63 | 37.65 | 26.29 | 0.00 | 0.00 | 37.65 | 26.29 |
Report: ZoneCoolingSummaryMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.103160E+10 | 2283.22 | 05-JAN-07:08 | 4.93 | 4.82 | 0.00 | 0.00 | 01-JAN-00:10 | 4.93 | 4.82 |
February | 0.183558E+10 | 3583.95 | 21-FEB-16:30 | 25.75 | 15.69 | 0.00 | 0.00 | 01-FEB-00:10 | 25.75 | 15.69 |
March | 0.367063E+10 | 5092.12 | 28-MAR-17:09 | 34.60 | 18.91 | 0.00 | 0.00 | 01-MAR-00:10 | 34.60 | 18.91 |
April | 0.502218E+10 | 7036.11 | 28-APR-12:10 | 36.60 | 19.98 | 0.00 | 0.00 | 01-APR-00:10 | 36.60 | 19.98 |
May | 0.629817E+10 | 8686.80 | 30-MAY-12:09 | 37.90 | 23.62 | 0.00 | 0.00 | 01-MAY-00:10 | 37.90 | 23.62 |
June | 0.622769E+10 | 7889.84 | 12-JUN-07:07 | 35.90 | 20.13 | 0.00 | 0.00 | 01-JUN-00:10 | 35.90 | 20.13 |
July | 0.595960E+10 | 7970.82 | 05-JUL-07:08 | 33.75 | 24.52 | 0.00 | 0.00 | 01-JUL-00:10 | 33.75 | 24.52 |
August | 0.606562E+10 | 6746.32 | 07-AUG-17:09 | 36.48 | 26.95 | 0.00 | 0.00 | 01-AUG-00:10 | 36.48 | 26.95 |
September | 0.528234E+10 | 6811.96 | 05-SEP-06:15 | 26.23 | 25.18 | 0.00 | 0.00 | 01-SEP-00:10 | 26.23 | 25.18 |
October | 0.469117E+10 | 5653.71 | 16-OCT-17:08 | 32.27 | 19.68 | 0.00 | 0.00 | 01-OCT-00:10 | 32.27 | 19.68 |
November | 0.313214E+10 | 4443.36 | 13-NOV-16:50 | 26.60 | 16.65 | 0.00 | 0.00 | 01-NOV-00:10 | 26.60 | 16.65 |
December | 0.151594E+10 | 2819.56 | 01-DEC-16:10 | 22.12 | 13.82 | 0.00 | 0.00 | 01-DEC-00:10 | 22.12 | 13.82 |
Annual Sum or Average | 0.507327E+11 | 0.00 | ||||||||
Minimum of Months | 0.103160E+10 | 2283.22 | 4.93 | 4.82 | 0.00 | 0.00 | 4.93 | 4.82 | ||
Maximum of Months | 0.629817E+10 | 8686.80 | 37.90 | 26.95 | 0.00 | 0.00 | 37.90 | 26.95 |
Report: ZoneCoolingSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.109312E+11 | 12561.00 | 26-JAN-17:00 | 18.60 | 12.70 | 0.193071E+10 | 2606.62 | 13-JAN-14:09 | 18.60 | 12.70 |
February | 0.123978E+11 | 28386.13 | 21-FEB-06:03 | 11.65 | 10.84 | 0.178960E+10 | 2606.65 | 24-FEB-10:09 | 20.63 | 14.93 |
March | 0.183577E+11 | 34238.90 | 13-MAR-04:02 | 20.88 | 16.38 | 0.215391E+10 | 2606.67 | 27-MAR-09:09 | 23.33 | 16.01 |
April | 0.207526E+11 | 34529.55 | 10-APR-04:02 | 18.53 | 13.30 | 0.191583E+10 | 2606.66 | 04-APR-09:09 | 18.53 | 13.30 |
May | 0.243639E+11 | 32410.03 | 25-MAY-04:03 | 26.00 | 23.62 | 0.207564E+10 | 2606.58 | 26-MAY-13:09 | 40.37 | 21.72 |
June | 0.237511E+11 | 32099.02 | 21-JUN-04:03 | 27.95 | 23.94 | 0.206886E+10 | 2606.62 | 05-JUN-13:09 | 27.95 | 23.94 |
July | 0.229709E+11 | 32129.86 | 13-JUL-04:03 | 27.87 | 26.38 | 0.192301E+10 | 2606.59 | 05-JUL-09:20 | 27.87 | 26.38 |
August | 0.230614E+11 | 32665.93 | 16-AUG-04:03 | 24.40 | 23.90 | 0.215889E+10 | 2606.57 | 21-AUG-13:39 | 29.17 | 27.62 |
September | 0.205547E+11 | 33242.69 | 27-SEP-04:02 | 23.75 | 21.11 | 0.191736E+10 | 2606.57 | 11-SEP-13:09 | 23.75 | 21.11 |
October | 0.197749E+11 | 34422.47 | 10-OCT-04:02 | 19.87 | 18.14 | 0.199184E+10 | 2606.68 | 30-OCT-09:09 | 21.27 | 16.75 |
November | 0.158406E+11 | 33274.01 | 13-NOV-05:02 | 14.83 | 12.40 | 0.196581E+10 | 2606.68 | 06-NOV-10:09 | 14.83 | 12.40 |
December | 0.121472E+11 | 13782.06 | 01-DEC-17:00 | 21.20 | 14.26 | 0.189404E+10 | 2606.63 | 18-DEC-10:00 | 21.70 | 14.67 |
Annual Sum or Average | 0.224904E+12 | 0.237855E+11 | ||||||||
Minimum of Months | 0.109312E+11 | 12561.00 | 11.65 | 10.84 | 0.178960E+10 | 2606.57 | 14.83 | 12.40 | ||
Maximum of Months | 0.243639E+11 | 34529.55 | 27.95 | 26.38 | 0.215889E+10 | 2606.68 | 40.37 | 27.62 |
Report: ZoneCoolingSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.971030E+10 | 12043.95 | 26-JAN-16:20 | 19.67 | 13.02 | 0.180641E+10 | 2606.59 | 25-JAN-14:00 | 19.67 | 13.02 |
February | 0.113799E+11 | 15828.16 | 23-FEB-15:00 | 25.80 | 14.10 | 0.173801E+10 | 2606.63 | 15-FEB-14:09 | 25.80 | 14.10 |
March | 0.182065E+11 | 34366.25 | 13-MAR-04:02 | 20.88 | 16.38 | 0.214144E+10 | 2606.68 | 29-MAR-09:00 | 26.40 | 19.31 |
April | 0.224023E+11 | 37696.20 | 18-APR-04:02 | 24.53 | 18.88 | 0.191540E+10 | 2606.68 | 05-APR-09:09 | 24.53 | 18.88 |
May | 0.273752E+11 | 37932.11 | 15-MAY-04:02 | 24.27 | 18.74 | 0.207686E+10 | 2606.65 | 01-MAY-09:09 | 24.27 | 18.74 |
June | 0.269268E+11 | 36870.31 | 19-JUN-04:02 | 27.82 | 23.26 | 0.206956E+10 | 2606.63 | 05-JUN-13:09 | 27.82 | 23.26 |
July | 0.256181E+11 | 36088.13 | 11-JUL-04:02 | 26.73 | 24.05 | 0.192439E+10 | 2606.57 | 07-JUL-13:09 | 26.73 | 24.05 |
August | 0.249949E+11 | 36932.90 | 15-AUG-04:02 | 27.05 | 25.93 | 0.215952E+10 | 2606.57 | 21-AUG-13:00 | 28.90 | 27.65 |
September | 0.215338E+11 | 37398.64 | 06-SEP-04:02 | 25.35 | 24.47 | 0.191702E+10 | 2606.64 | 27-SEP-09:09 | 28.62 | 20.79 |
October | 0.195311E+11 | 38494.52 | 10-OCT-04:02 | 19.87 | 18.14 | 0.198592E+10 | 2606.69 | 10-OCT-09:09 | 25.82 | 20.21 |
November | 0.144695E+11 | 17219.20 | 13-NOV-15:00 | 28.20 | 16.17 | 0.193790E+10 | 2606.68 | 06-NOV-10:00 | 28.20 | 16.17 |
December | 0.105657E+11 | 13229.83 | 01-DEC-16:20 | 21.93 | 13.92 | 0.180181E+10 | 2606.62 | 28-DEC-14:09 | 24.58 | 15.31 |
Annual Sum or Average | 0.232714E+12 | 0.234743E+11 | ||||||||
Minimum of Months | 0.971030E+10 | 12043.95 | 19.67 | 13.02 | 0.173801E+10 | 2606.57 | 19.67 | 13.02 | ||
Maximum of Months | 0.273752E+11 | 38494.52 | 28.20 | 25.93 | 0.215952E+10 | 2606.69 | 28.90 | 27.65 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.172098E+10 | 2713.50 | 26-JAN-14:50 | 21.75 | 13.69 | 0.355948E+09 | 549.49 | 26-JAN-14:00 | 21.60 | 13.66 |
February | 0.237842E+10 | 4437.14 | 23-FEB-14:40 | 26.00 | 14.03 | 0.350225E+09 | 549.49 | 24-FEB-14:00 | 26.40 | 17.38 |
March | 0.465678E+10 | 6544.63 | 13-MAR-15:20 | 32.77 | 18.67 | 0.445549E+09 | 549.51 | 29-MAR-09:00 | 26.40 | 19.31 |
April | 0.703244E+10 | 15084.48 | 16-APR-15:22 | 39.50 | 22.49 | 0.404045E+09 | 549.50 | 21-APR-09:09 | 27.48 | 18.82 |
May | 0.959120E+10 | 15549.05 | 28-MAY-16:31 | 41.90 | 19.53 | 0.438936E+09 | 549.50 | 01-MAY-09:09 | 41.90 | 19.53 |
June | 0.967664E+10 | 15626.86 | 04-JUN-16:21 | 42.05 | 22.41 | 0.437403E+09 | 549.50 | 05-JUN-13:09 | 42.20 | 22.45 |
July | 0.890881E+10 | 15224.36 | 04-JUL-17:12 | 40.00 | 24.23 | 0.406978E+09 | 549.48 | 05-JUL-13:00 | 37.90 | 25.56 |
August | 0.829130E+10 | 15173.79 | 06-AUG-14:42 | 36.23 | 26.26 | 0.456088E+09 | 549.48 | 21-AUG-13:00 | 28.90 | 27.65 |
September | 0.659537E+10 | 12782.60 | 25-SEP-04:02 | 26.32 | 23.72 | 0.404711E+09 | 549.50 | 27-SEP-09:09 | 28.62 | 20.79 |
October | 0.526272E+10 | 9463.97 | 01-OCT-15:02 | 35.92 | 19.96 | 0.416633E+09 | 549.51 | 10-OCT-09:09 | 25.82 | 20.21 |
November | 0.321203E+10 | 4811.94 | 09-NOV-14:30 | 29.30 | 17.79 | 0.397552E+09 | 549.50 | 06-NOV-10:00 | 29.30 | 17.79 |
December | 0.195990E+10 | 2691.59 | 01-DEC-15:00 | 23.40 | 13.35 | 0.356679E+09 | 549.49 | 28-DEC-14:00 | 24.50 | 15.39 |
Annual Sum or Average | 0.692866E+11 | 0.487075E+10 | ||||||||
Minimum of Months | 0.172098E+10 | 2691.59 | 21.75 | 13.35 | 0.350225E+09 | 549.48 | 21.60 | 13.66 | ||
Maximum of Months | 0.967664E+10 | 15626.86 | 42.05 | 26.26 | 0.456088E+09 | 549.51 | 42.20 | 27.65 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.148559E+10 | 2226.55 | 26-JAN-14:10 | 22.35 | 13.84 | 0.238649E+09 | 347.87 | 12-JAN-14:00 | 22.35 | 13.84 |
February | 0.215248E+10 | 4107.01 | 22-FEB-10:50 | 23.10 | 14.47 | 0.230021E+09 | 347.88 | 24-FEB-10:00 | 22.30 | 15.46 |
March | 0.426166E+10 | 9385.74 | 12-MAR-09:53 | 25.90 | 17.17 | 0.285035E+09 | 347.89 | 06-MAR-10:20 | 25.90 | 17.17 |
April | 0.631722E+10 | 12029.30 | 16-APR-10:02 | 35.32 | 21.70 | 0.256148E+09 | 348.04 | 28-APR-09:50 | 33.47 | 18.33 |
May | 0.792501E+10 | 12349.46 | 29-MAY-09:22 | 34.75 | 21.56 | 0.278000E+09 | 348.01 | 03-MAY-09:00 | 34.75 | 21.56 |
June | 0.737500E+10 | 11901.05 | 11-JUN-10:22 | 37.75 | 25.19 | 0.276934E+09 | 348.04 | 13-JUN-09:20 | 35.17 | 26.05 |
July | 0.650646E+10 | 12043.16 | 04-JUL-08:32 | 33.47 | 25.46 | 0.257675E+09 | 347.91 | 07-JUL-09:00 | 36.90 | 24.55 |
August | 0.601350E+10 | 12121.93 | 06-AUG-10:02 | 32.50 | 25.30 | 0.288732E+09 | 347.87 | 21-AUG-13:00 | 28.90 | 27.65 |
September | 0.513530E+10 | 8581.09 | 25-SEP-04:02 | 26.32 | 23.72 | 0.256194E+09 | 347.88 | 27-SEP-09:09 | 28.62 | 20.79 |
October | 0.454048E+10 | 11650.70 | 09-OCT-11:02 | 30.15 | 20.48 | 0.264561E+09 | 347.89 | 17-OCT-09:20 | 26.63 | 18.34 |
November | 0.287099E+10 | 4164.82 | 09-NOV-10:30 | 25.75 | 18.10 | 0.257282E+09 | 347.89 | 06-NOV-10:00 | 25.75 | 18.10 |
December | 0.165655E+10 | 2497.74 | 01-DEC-10:50 | 19.88 | 12.01 | 0.237770E+09 | 347.87 | 28-DEC-14:00 | 24.50 | 15.39 |
Annual Sum or Average | 0.562402E+11 | 0.312700E+10 | ||||||||
Minimum of Months | 0.148559E+10 | 2226.55 | 19.88 | 12.01 | 0.230021E+09 | 347.87 | 22.30 | 13.84 | ||
Maximum of Months | 0.792501E+10 | 12349.46 | 37.75 | 25.46 | 0.288732E+09 | 348.04 | 36.90 | 27.65 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.380335E+10 | 8284.51 | 12-JAN-14:10 | 23.35 | 14.02 | 0.390760E+09 | 549.50 | 25-JAN-14:00 | 23.00 | 13.41 |
February | 0.465173E+10 | 16497.20 | 20-FEB-14:22 | 26.35 | 13.75 | 0.364384E+09 | 549.74 | 22-FEB-14:00 | 27.10 | 16.20 |
March | 0.739740E+10 | 15875.83 | 12-MAR-11:53 | 29.70 | 18.51 | 0.449121E+09 | 549.78 | 08-MAR-14:50 | 29.70 | 18.51 |
April | 0.871810E+10 | 15866.14 | 16-APR-13:22 | 39.30 | 21.89 | 0.404378E+09 | 549.67 | 21-APR-13:00 | 35.00 | 19.79 |
May | 0.997936E+10 | 15906.52 | 28-MAY-15:11 | 42.23 | 19.17 | 0.438938E+09 | 549.68 | 08-MAY-13:00 | 42.23 | 19.17 |
June | 0.962325E+10 | 15828.81 | 04-JUN-15:41 | 42.30 | 22.20 | 0.437371E+09 | 549.62 | 05-JUN-13:00 | 42.70 | 22.44 |
July | 0.897472E+10 | 15454.44 | 30-JUL-12:53 | 33.40 | 26.52 | 0.406963E+09 | 549.48 | 05-JUL-13:00 | 33.40 | 26.52 |
August | 0.874594E+10 | 15891.65 | 06-AUG-14:42 | 36.23 | 26.26 | 0.456137E+09 | 549.60 | 07-AUG-13:00 | 37.20 | 26.26 |
September | 0.806807E+10 | 15790.41 | 24-SEP-14:02 | 35.10 | 24.64 | 0.404957E+09 | 549.70 | 19-SEP-13:00 | 35.10 | 24.64 |
October | 0.890570E+10 | 17386.40 | 09-OCT-12:22 | 31.85 | 20.10 | 0.418935E+09 | 564.95 | 02-OCT-13:39 | 31.85 | 20.10 |
November | 0.723340E+10 | 16468.20 | 23-NOV-13:22 | 25.70 | 14.25 | 0.408708E+09 | 549.79 | 17-NOV-14:00 | 25.70 | 14.25 |
December | 0.439851E+10 | 15581.89 | 03-DEC-13:32 | 24.33 | 14.17 | 0.385066E+09 | 549.64 | 01-DEC-14:20 | 24.33 | 14.17 |
Annual Sum or Average | 0.904995E+11 | 0.496572E+10 | ||||||||
Minimum of Months | 0.380335E+10 | 8284.51 | 23.35 | 13.75 | 0.364384E+09 | 549.48 | 23.00 | 13.41 | ||
Maximum of Months | 0.997936E+10 | 17386.40 | 42.30 | 26.52 | 0.456137E+09 | 564.95 | 42.70 | 26.52 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.162908E+10 | 3548.67 | 31-JAN-16:10 | 20.95 | 11.21 | 0.227208E+09 | 347.85 | 25-JAN-14:00 | 20.95 | 11.21 |
February | 0.222563E+10 | 8183.43 | 20-FEB-15:43 | 25.72 | 14.13 | 0.219229E+09 | 347.85 | 24-FEB-14:00 | 26.40 | 17.38 |
March | 0.426083E+10 | 13313.54 | 26-MAR-16:12 | 29.73 | 16.34 | 0.280192E+09 | 347.86 | 29-MAR-09:00 | 26.40 | 19.31 |
April | 0.624053E+10 | 13609.92 | 30-APR-16:22 | 37.45 | 18.00 | 0.255581E+09 | 347.86 | 21-APR-09:09 | 37.45 | 18.00 |
May | 0.776571E+10 | 14215.68 | 28-MAY-16:31 | 41.90 | 19.53 | 0.277835E+09 | 347.85 | 01-MAY-09:09 | 41.90 | 19.53 |
June | 0.759264E+10 | 14159.55 | 04-JUN-16:21 | 42.05 | 22.41 | 0.276860E+09 | 347.85 | 07-JUN-09:09 | 37.65 | 20.59 |
July | 0.646177E+10 | 13384.74 | 04-JUL-16:32 | 39.83 | 24.41 | 0.257546E+09 | 347.84 | 05-JUL-13:00 | 37.90 | 25.56 |
August | 0.599066E+10 | 13420.65 | 06-AUG-14:42 | 36.23 | 26.26 | 0.288619E+09 | 347.84 | 21-AUG-13:00 | 28.90 | 27.65 |
September | 0.515788E+10 | 12948.92 | 24-SEP-15:22 | 34.95 | 25.05 | 0.255997E+09 | 347.85 | 27-SEP-09:09 | 28.62 | 20.79 |
October | 0.451181E+10 | 13053.73 | 01-OCT-15:42 | 35.58 | 20.12 | 0.262754E+09 | 347.86 | 10-OCT-09:09 | 25.82 | 20.21 |
November | 0.304325E+10 | 5742.15 | 08-NOV-15:30 | 29.55 | 18.29 | 0.249435E+09 | 347.85 | 06-NOV-10:00 | 29.55 | 18.29 |
December | 0.184450E+10 | 3899.74 | 01-DEC-15:30 | 22.85 | 13.56 | 0.225343E+09 | 347.85 | 28-DEC-14:00 | 24.50 | 15.39 |
Annual Sum or Average | 0.567243E+11 | 0.307660E+10 | ||||||||
Minimum of Months | 0.162908E+10 | 3548.67 | 20.95 | 11.21 | 0.219229E+09 | 347.84 | 20.95 | 11.21 | ||
Maximum of Months | 0.776571E+10 | 14215.68 | 42.05 | 26.26 | 0.288619E+09 | 347.86 | 41.90 | 27.65 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.203770E+10 | 2496.83 | 26-JAN-14:10 | 22.35 | 13.84 | 0.382930E+09 | 549.49 | 13-JAN-14:09 | 22.35 | 13.84 |
February | 0.228948E+10 | 3554.56 | 24-FEB-15:00 | 26.40 | 17.38 | 0.363595E+09 | 549.50 | 24-FEB-10:09 | 26.40 | 17.38 |
March | 0.378628E+10 | 4941.83 | 13-MAR-15:20 | 32.77 | 18.67 | 0.449122E+09 | 549.50 | 27-MAR-09:09 | 23.33 | 16.01 |
April | 0.550044E+10 | 7403.63 | 28-APR-04:02 | 27.93 | 17.10 | 0.403592E+09 | 549.50 | 21-APR-09:09 | 27.93 | 17.10 |
May | 0.788086E+10 | 12284.97 | 07-MAY-16:31 | 41.77 | 21.63 | 0.438526E+09 | 549.52 | 31-MAY-13:00 | 39.90 | 22.41 |
June | 0.857568E+10 | 12440.11 | 11-JUN-16:11 | 43.30 | 23.15 | 0.437242E+09 | 549.51 | 20-JUN-13:09 | 33.57 | 27.49 |
July | 0.862057E+10 | 12247.39 | 09-JUL-17:32 | 35.63 | 27.50 | 0.406927E+09 | 549.49 | 13-JUL-13:09 | 34.20 | 27.70 |
August | 0.870724E+10 | 10783.09 | 14-AUG-04:03 | 28.85 | 26.06 | 0.456245E+09 | 549.50 | 21-AUG-13:30 | 29.30 | 27.60 |
September | 0.725788E+10 | 12170.69 | 24-SEP-16:32 | 34.33 | 25.45 | 0.405123E+09 | 549.50 | 11-SEP-13:09 | 34.33 | 25.45 |
October | 0.588723E+10 | 10198.13 | 01-OCT-14:42 | 35.98 | 19.91 | 0.420005E+09 | 549.50 | 30-OCT-09:09 | 21.27 | 16.75 |
November | 0.367168E+10 | 4541.58 | 09-NOV-14:10 | 29.37 | 17.83 | 0.412019E+09 | 549.50 | 06-NOV-10:09 | 29.37 | 17.83 |
December | 0.235399E+10 | 2911.99 | 01-DEC-15:00 | 23.40 | 13.35 | 0.387118E+09 | 549.49 | 29-DEC-10:30 | 18.20 | 13.53 |
Annual Sum or Average | 0.665691E+11 | 0.496244E+10 | ||||||||
Minimum of Months | 0.203770E+10 | 2496.83 | 22.35 | 13.35 | 0.363595E+09 | 549.49 | 18.20 | 13.53 | ||
Maximum of Months | 0.870724E+10 | 12440.11 | 43.30 | 27.50 | 0.456245E+09 | 549.52 | 39.90 | 27.70 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.170342E+10 | 2437.40 | 26-JAN-11:00 | 19.70 | 13.19 | 0.255253E+09 | 347.87 | 05-JAN-10:39 | 19.70 | 13.19 |
February | 0.211414E+10 | 3775.97 | 22-FEB-10:40 | 22.60 | 14.39 | 0.236295E+09 | 347.88 | 15-FEB-10:00 | 22.60 | 14.39 |
March | 0.365084E+10 | 5289.03 | 28-MAR-10:30 | 29.80 | 18.26 | 0.286563E+09 | 347.88 | 27-MAR-09:09 | 29.80 | 18.26 |
April | 0.522288E+10 | 9617.09 | 30-APR-09:42 | 30.90 | 15.93 | 0.256115E+09 | 348.02 | 28-APR-09:50 | 30.90 | 15.93 |
May | 0.677155E+10 | 10444.94 | 07-MAY-09:51 | 36.20 | 20.86 | 0.277947E+09 | 347.98 | 26-MAY-09:00 | 35.60 | 21.80 |
June | 0.664270E+10 | 10633.09 | 11-JUN-09:32 | 35.83 | 25.01 | 0.276942E+09 | 349.53 | 12-JUN-09:50 | 39.75 | 22.08 |
July | 0.630552E+10 | 10203.63 | 16-JUL-10:32 | 33.10 | 27.50 | 0.257728E+09 | 347.87 | 13-JUL-13:09 | 33.10 | 27.50 |
August | 0.629088E+10 | 10203.93 | 06-AUG-10:23 | 32.90 | 25.51 | 0.288917E+09 | 347.87 | 21-AUG-13:39 | 29.17 | 27.62 |
September | 0.559352E+10 | 9860.03 | 24-SEP-16:32 | 34.33 | 25.45 | 0.256584E+09 | 347.87 | 11-SEP-13:09 | 34.33 | 25.45 |
October | 0.501930E+10 | 10141.79 | 09-OCT-11:02 | 30.15 | 20.48 | 0.266414E+09 | 347.88 | 31-OCT-09:09 | 21.83 | 17.04 |
November | 0.331588E+10 | 4438.54 | 13-NOV-10:30 | 23.45 | 14.94 | 0.262303E+09 | 347.88 | 06-NOV-10:09 | 23.45 | 14.94 |
December | 0.204411E+10 | 3066.32 | 01-DEC-10:30 | 19.25 | 11.77 | 0.251459E+09 | 347.87 | 18-DEC-10:00 | 21.70 | 14.67 |
Annual Sum or Average | 0.546747E+11 | 0.317252E+10 | ||||||||
Minimum of Months | 0.170342E+10 | 2437.40 | 19.25 | 11.77 | 0.236295E+09 | 347.87 | 19.70 | 13.19 | ||
Maximum of Months | 0.677155E+10 | 10633.09 | 36.20 | 27.50 | 0.288917E+09 | 349.53 | 39.75 | 27.62 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.317911E+10 | 7337.87 | 12-JAN-14:10 | 23.35 | 14.02 | 0.389288E+09 | 549.51 | 25-JAN-14:00 | 23.00 | 13.41 |
February | 0.400430E+10 | 13234.70 | 20-FEB-14:22 | 26.35 | 13.75 | 0.363632E+09 | 549.73 | 23-FEB-14:30 | 26.10 | 14.00 |
March | 0.688181E+10 | 12407.29 | 28-MAR-16:10 | 35.40 | 18.76 | 0.449836E+09 | 647.66 | 28-MAR-12:09 | 35.40 | 18.76 |
April | 0.907793E+10 | 13646.27 | 27-APR-16:50 | 39.30 | 18.95 | 0.411739E+09 | 740.59 | 27-APR-12:09 | 39.30 | 18.95 |
May | 0.115112E+11 | 14884.45 | 01-MAY-16:50 | 43.07 | 22.15 | 0.453691E+09 | 807.65 | 01-MAY-12:09 | 43.07 | 22.15 |
June | 0.118357E+11 | 15207.83 | 12-JUN-17:00 | 43.90 | 22.35 | 0.451436E+09 | 827.76 | 12-JUN-12:09 | 43.90 | 22.35 |
July | 0.109942E+11 | 13944.68 | 03-JUL-17:00 | 39.50 | 25.70 | 0.414667E+09 | 757.05 | 07-JUL-12:09 | 39.13 | 24.79 |
August | 0.115049E+11 | 13102.43 | 07-AUG-16:50 | 36.68 | 26.89 | 0.462879E+09 | 697.07 | 07-AUG-12:09 | 36.68 | 26.89 |
September | 0.104079E+11 | 13190.04 | 29-SEP-12:00 | 35.40 | 22.70 | 0.414223E+09 | 713.86 | 29-SEP-12:09 | 35.52 | 22.70 |
October | 0.105007E+11 | 14092.94 | 01-OCT-12:42 | 34.97 | 19.94 | 0.433288E+09 | 739.73 | 02-OCT-12:09 | 35.70 | 21.30 |
November | 0.797819E+10 | 13974.32 | 12-NOV-13:42 | 28.12 | 16.00 | 0.415075E+09 | 613.84 | 09-NOV-13:09 | 28.12 | 16.00 |
December | 0.411291E+10 | 10896.75 | 03-DEC-11:43 | 22.38 | 14.19 | 0.389553E+09 | 549.68 | 01-DEC-14:00 | 22.38 | 14.19 |
Annual Sum or Average | 0.101989E+12 | 0.504931E+10 | ||||||||
Minimum of Months | 0.317911E+10 | 7337.87 | 22.38 | 13.75 | 0.363632E+09 | 549.51 | 22.38 | 13.41 | ||
Maximum of Months | 0.118357E+11 | 15207.83 | 43.90 | 26.89 | 0.462879E+09 | 827.76 | 43.90 | 26.89 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.178120E+10 | 3091.93 | 31-JAN-16:30 | 20.65 | 11.16 | 0.246164E+09 | 347.84 | 13-JAN-14:00 | 20.65 | 11.16 |
February | 0.204316E+10 | 4336.86 | 21-FEB-16:10 | 25.98 | 15.67 | 0.231294E+09 | 347.85 | 24-FEB-10:09 | 20.63 | 14.93 |
March | 0.354524E+10 | 8553.11 | 26-MAR-17:03 | 28.93 | 15.95 | 0.285186E+09 | 347.85 | 27-MAR-09:09 | 23.33 | 16.01 |
April | 0.510484E+10 | 10694.05 | 30-APR-16:22 | 37.45 | 18.00 | 0.256004E+09 | 347.85 | 21-APR-09:09 | 37.45 | 18.00 |
May | 0.657066E+10 | 11078.71 | 07-MAY-16:31 | 41.77 | 21.63 | 0.277878E+09 | 347.87 | 31-MAY-13:00 | 39.90 | 22.41 |
June | 0.681922E+10 | 11147.00 | 11-JUN-16:11 | 43.30 | 23.15 | 0.276967E+09 | 347.86 | 20-JUN-13:09 | 33.57 | 27.49 |
July | 0.623339E+10 | 10727.87 | 02-JUL-16:12 | 40.37 | 26.43 | 0.257683E+09 | 347.85 | 13-JUL-13:09 | 34.20 | 27.70 |
August | 0.624358E+10 | 9708.01 | 27-AUG-15:32 | 35.23 | 29.16 | 0.288895E+09 | 347.85 | 21-AUG-13:39 | 35.23 | 29.16 |
September | 0.558501E+10 | 11049.05 | 24-SEP-16:32 | 34.33 | 25.45 | 0.256600E+09 | 347.85 | 11-SEP-13:09 | 34.33 | 25.45 |
October | 0.490834E+10 | 11223.75 | 01-OCT-16:02 | 35.32 | 20.17 | 0.266293E+09 | 347.86 | 30-OCT-09:09 | 21.27 | 16.75 |
November | 0.330328E+10 | 9470.70 | 05-NOV-15:22 | 28.45 | 17.59 | 0.261592E+09 | 347.86 | 06-NOV-10:09 | 23.13 | 17.24 |
December | 0.206751E+10 | 3678.44 | 01-DEC-15:40 | 22.67 | 13.61 | 0.246550E+09 | 347.85 | 29-DEC-10:30 | 18.20 | 13.53 |
Annual Sum or Average | 0.542054E+11 | 0.315111E+10 | ||||||||
Minimum of Months | 0.178120E+10 | 3091.93 | 20.65 | 11.16 | 0.231294E+09 | 347.84 | 18.20 | 11.16 | ||
Maximum of Months | 0.681922E+10 | 11223.75 | 43.30 | 29.16 | 0.288895E+09 | 347.87 | 39.90 | 29.16 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.193243E+10 | 2806.87 | 26-JAN-14:30 | 22.05 | 13.77 | 0.379616E+09 | 549.49 | 13-JAN-14:09 | 22.05 | 13.77 |
February | 0.245332E+10 | 4174.08 | 23-FEB-14:30 | 26.10 | 14.00 | 0.365690E+09 | 549.50 | 24-FEB-10:09 | 20.63 | 14.93 |
March | 0.451630E+10 | 5845.09 | 13-MAR-15:20 | 32.77 | 18.67 | 0.451640E+09 | 549.50 | 29-MAR-09:09 | 24.57 | 18.84 |
April | 0.642694E+10 | 12412.98 | 30-APR-16:11 | 37.57 | 18.06 | 0.404489E+09 | 549.50 | 21-APR-09:09 | 37.57 | 18.06 |
May | 0.851603E+10 | 12741.08 | 28-MAY-16:31 | 41.90 | 19.53 | 0.438919E+09 | 549.49 | 05-MAY-09:30 | 41.90 | 19.53 |
June | 0.859693E+10 | 12953.27 | 04-JUN-14:32 | 42.03 | 22.05 | 0.437384E+09 | 549.49 | 07-JUN-09:20 | 37.90 | 20.70 |
July | 0.791104E+10 | 12552.93 | 04-JUL-17:12 | 40.00 | 24.23 | 0.406912E+09 | 549.49 | 05-JUL-09:20 | 35.67 | 25.11 |
August | 0.758901E+10 | 12413.89 | 06-AUG-15:32 | 36.30 | 26.24 | 0.456074E+09 | 549.48 | 21-AUG-13:00 | 28.90 | 27.65 |
September | 0.621860E+10 | 12422.32 | 24-SEP-16:32 | 34.33 | 25.45 | 0.404866E+09 | 549.48 | 08-SEP-13:00 | 34.33 | 25.45 |
October | 0.513356E+10 | 8357.81 | 02-OCT-04:02 | 21.82 | 17.78 | 0.419298E+09 | 549.50 | 30-OCT-09:09 | 21.27 | 16.75 |
November | 0.330494E+10 | 4440.97 | 09-NOV-14:10 | 29.37 | 17.83 | 0.409224E+09 | 549.50 | 06-NOV-10:09 | 29.37 | 17.83 |
December | 0.215835E+10 | 2815.66 | 01-DEC-15:00 | 23.40 | 13.35 | 0.379835E+09 | 549.49 | 18-DEC-14:00 | 22.10 | 15.00 |
Annual Sum or Average | 0.647574E+11 | 0.495395E+10 | ||||||||
Minimum of Months | 0.193243E+10 | 2806.87 | 21.82 | 13.35 | 0.365690E+09 | 549.48 | 20.63 | 13.77 | ||
Maximum of Months | 0.859693E+10 | 12953.27 | 42.03 | 26.24 | 0.456074E+09 | 549.50 | 41.90 | 27.65 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.164004E+10 | 2540.28 | 26-JAN-11:10 | 19.98 | 13.28 | 0.183014E+09 | 338.72 | 27-JAN-13:20 | 16.07 | 11.85 |
February | 0.221459E+10 | 4308.39 | 22-FEB-10:00 | 20.60 | 13.92 | 0.173081E+09 | 338.73 | 15-FEB-11:20 | 20.60 | 13.92 |
March | 0.407351E+10 | 10157.18 | 12-MAR-10:23 | 27.05 | 17.61 | 0.211399E+09 | 338.73 | 16-MAR-10:20 | 20.53 | 15.55 |
April | 0.575294E+10 | 11495.85 | 30-APR-08:52 | 28.40 | 14.74 | 0.189745E+09 | 339.15 | 14-APR-10:00 | 28.40 | 14.74 |
May | 0.704362E+10 | 11173.52 | 29-MAY-09:22 | 34.75 | 21.56 | 0.205757E+09 | 339.13 | 03-MAY-07:40 | 34.75 | 21.56 |
June | 0.653125E+10 | 11352.53 | 11-JUN-09:32 | 35.83 | 25.01 | 0.204689E+09 | 339.10 | 12-JUN-10:00 | 41.40 | 22.35 |
July | 0.573098E+10 | 10952.12 | 04-JUL-08:32 | 33.47 | 25.46 | 0.191069E+09 | 339.11 | 05-JUL-10:30 | 36.60 | 25.30 |
August | 0.542518E+10 | 10753.48 | 06-AUG-09:32 | 31.87 | 24.94 | 0.213325E+09 | 338.97 | 07-AUG-10:50 | 34.20 | 26.29 |
September | 0.476537E+10 | 10111.88 | 24-SEP-16:32 | 34.33 | 25.45 | 0.189736E+09 | 338.74 | 26-SEP-07:19 | 26.03 | 19.88 |
October | 0.432235E+10 | 10958.93 | 01-OCT-10:12 | 30.47 | 19.50 | 0.196664E+09 | 338.74 | 10-OCT-07:19 | 21.97 | 18.94 |
November | 0.291576E+10 | 4297.90 | 13-NOV-10:00 | 22.20 | 14.45 | 0.192297E+09 | 338.73 | 16-NOV-11:09 | 24.57 | 17.22 |
December | 0.182518E+10 | 3038.09 | 01-DEC-10:00 | 18.30 | 11.37 | 0.181148E+09 | 338.72 | 18-DEC-11:20 | 22.00 | 14.81 |
Annual Sum or Average | 0.522408E+11 | 0.233192E+10 | ||||||||
Minimum of Months | 0.164004E+10 | 2540.28 | 18.30 | 11.37 | 0.173081E+09 | 338.72 | 16.07 | 11.85 | ||
Maximum of Months | 0.704362E+10 | 11495.85 | 35.83 | 25.46 | 0.213325E+09 | 339.15 | 41.40 | 26.29 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.424362E+10 | 8127.95 | 12-JAN-13:50 | 23.12 | 13.90 | 0.404435E+09 | 549.64 | 12-JAN-14:50 | 23.55 | 14.16 |
February | 0.477787E+10 | 13519.66 | 20-FEB-15:13 | 26.07 | 14.07 | 0.374114E+09 | 549.73 | 07-FEB-14:50 | 26.07 | 14.07 |
March | 0.712142E+10 | 13901.55 | 12-MAR-13:02 | 30.78 | 19.08 | 0.453377E+09 | 550.99 | 30-MAR-13:50 | 32.05 | 19.26 |
April | 0.795896E+10 | 13231.90 | 02-APR-12:43 | 31.57 | 20.45 | 0.404877E+09 | 549.67 | 06-APR-13:00 | 33.00 | 16.35 |
May | 0.885149E+10 | 13051.26 | 28-MAY-15:11 | 42.23 | 19.17 | 0.438947E+09 | 549.67 | 19-MAY-13:50 | 42.23 | 19.17 |
June | 0.853444E+10 | 13292.49 | 04-JUN-14:32 | 42.03 | 22.05 | 0.437367E+09 | 549.69 | 06-JUN-13:30 | 43.30 | 22.42 |
July | 0.795982E+10 | 12777.19 | 04-JUL-15:52 | 39.70 | 24.71 | 0.406912E+09 | 549.67 | 10-JUL-13:30 | 39.20 | 26.69 |
August | 0.799224E+10 | 13100.79 | 06-AUG-12:53 | 35.30 | 26.31 | 0.456146E+09 | 549.59 | 07-AUG-13:50 | 37.08 | 26.29 |
September | 0.758754E+10 | 13336.39 | 24-SEP-12:32 | 34.33 | 24.81 | 0.405151E+09 | 556.38 | 28-SEP-13:39 | 35.37 | 22.75 |
October | 0.852096E+10 | 14459.19 | 01-OCT-11:32 | 33.20 | 19.80 | 0.421632E+09 | 582.35 | 02-OCT-13:39 | 36.33 | 21.10 |
November | 0.731427E+10 | 14514.63 | 12-NOV-13:12 | 27.87 | 16.14 | 0.414338E+09 | 559.68 | 13-NOV-14:09 | 28.20 | 15.99 |
December | 0.483468E+10 | 13398.05 | 03-DEC-13:23 | 24.25 | 14.17 | 0.396473E+09 | 549.70 | 04-DEC-14:00 | 23.20 | 14.27 |
Annual Sum or Average | 0.856973E+11 | 0.501377E+10 | ||||||||
Minimum of Months | 0.424362E+10 | 8127.95 | 23.12 | 13.90 | 0.374114E+09 | 549.59 | 23.20 | 14.07 | ||
Maximum of Months | 0.885149E+10 | 14514.63 | 42.23 | 26.31 | 0.456146E+09 | 582.35 | 43.30 | 26.69 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.181123E+10 | 3570.74 | 31-JAN-16:10 | 20.95 | 11.21 | 0.239706E+09 | 347.84 | 25-JAN-14:00 | 20.95 | 11.21 |
February | 0.224296E+10 | 6663.32 | 20-FEB-16:33 | 24.93 | 14.44 | 0.229499E+09 | 347.85 | 24-FEB-10:20 | 20.97 | 15.04 |
March | 0.406368E+10 | 11146.21 | 26-MAR-15:43 | 30.07 | 16.56 | 0.285275E+09 | 347.86 | 30-MAR-13:50 | 32.05 | 19.26 |
April | 0.571283E+10 | 11814.35 | 30-APR-16:11 | 37.57 | 18.06 | 0.256140E+09 | 347.86 | 21-APR-09:09 | 37.57 | 18.06 |
May | 0.694493E+10 | 12007.63 | 28-MAY-16:31 | 41.90 | 19.53 | 0.277888E+09 | 347.85 | 31-MAY-13:00 | 39.90 | 22.41 |
June | 0.678458E+10 | 12086.39 | 11-JUN-16:11 | 43.30 | 23.15 | 0.276916E+09 | 347.85 | 07-JUN-09:20 | 43.30 | 23.15 |
July | 0.573600E+10 | 11469.14 | 02-JUL-16:12 | 40.37 | 26.43 | 0.257563E+09 | 347.85 | 05-JUL-09:20 | 35.67 | 25.11 |
August | 0.547168E+10 | 11657.40 | 06-AUG-16:12 | 36.20 | 26.31 | 0.288673E+09 | 347.84 | 21-AUG-13:00 | 28.90 | 27.65 |
September | 0.483156E+10 | 11701.57 | 24-SEP-16:32 | 34.33 | 25.45 | 0.256284E+09 | 347.84 | 08-SEP-13:00 | 34.33 | 25.45 |
October | 0.431200E+10 | 11493.02 | 01-OCT-15:31 | 35.67 | 20.08 | 0.265293E+09 | 347.86 | 30-OCT-09:09 | 21.27 | 16.75 |
November | 0.303451E+10 | 10151.27 | 05-NOV-15:22 | 28.45 | 17.59 | 0.258048E+09 | 347.86 | 06-NOV-10:09 | 23.13 | 17.24 |
December | 0.199724E+10 | 3893.88 | 01-DEC-15:30 | 22.85 | 13.56 | 0.238537E+09 | 347.85 | 18-DEC-14:00 | 22.10 | 15.00 |
Annual Sum or Average | 0.529432E+11 | 0.312982E+10 | ||||||||
Minimum of Months | 0.181123E+10 | 3570.74 | 20.95 | 11.21 | 0.229499E+09 | 347.84 | 20.95 | 11.21 | ||
Maximum of Months | 0.694493E+10 | 12086.39 | 43.30 | 26.43 | 0.288673E+09 | 347.86 | 43.30 | 27.65 |
Report: ZoneHeatingSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 7.83 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 9.73 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 15.55 |
April | 0.00 | 0.00 | 01-APR-00:10 | 23.70 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 30.53 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 28.05 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 32.95 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 28.43 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.58 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 17.72 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 12.50 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 7.83 | |
Maximum of Months | 0.00 | 0.00 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.116590E+10 | 8891.82 | 02-JAN-07:03 | 6.78 |
February | 0.630669E+09 | 4862.98 | 02-FEB-06:03 | 6.92 |
March | 0.305569E+09 | 6401.99 | 13-MAR-04:02 | 20.88 |
April | 70689070.79 | 7340.16 | 10-APR-04:02 | 18.53 |
May | 28838426.62 | 6373.88 | 15-MAY-04:02 | 24.27 |
June | 17091845.14 | 5733.08 | 19-JUN-04:02 | 27.82 |
July | 13559017.61 | 3944.35 | 11-JUL-04:02 | 26.73 |
August | 16999846.83 | 5816.08 | 21-AUG-04:02 | 25.67 |
September | 29133784.04 | 6331.52 | 25-SEP-04:02 | 26.32 |
October | 0.194292E+09 | 7093.37 | 02-OCT-04:02 | 21.82 |
November | 0.504609E+09 | 4485.20 | 24-NOV-06:03 | 10.50 |
December | 0.952080E+09 | 5341.66 | 21-DEC-06:02 | 5.27 |
Annual Sum or Average | 0.392943E+10 | |||
Minimum of Months | 13559017.61 | 3944.35 | 5.27 | |
Maximum of Months | 0.116590E+10 | 8891.82 | 27.82 |
Report: ZoneHeatingSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.464734E+09 | 3131.81 | 08-JAN-12:20 | 18.10 |
February | 84148968.79 | 3192.56 | 05-FEB-13:33 | 23.07 |
March | 22756382.92 | 2393.99 | 26-MAR-15:43 | 30.07 |
April | 19600341.52 | 2989.10 | 28-APR-04:02 | 27.93 |
May | 21608047.01 | 3227.69 | 17-MAY-04:02 | 29.18 |
June | 22727257.94 | 3350.78 | 15-JUN-04:02 | 29.38 |
July | 23383502.71 | 3670.09 | 14-JUL-04:02 | 29.58 |
August | 19086315.32 | 3440.05 | 03-AUG-04:02 | 28.73 |
September | 20473341.90 | 3036.72 | 11-SEP-04:02 | 25.87 |
October | 28251103.10 | 2349.03 | 11-OCT-04:02 | 24.15 |
November | 34803210.50 | 2945.92 | 26-NOV-10:53 | 24.00 |
December | 0.185122E+09 | 3962.58 | 24-DEC-13:43 | 24.00 |
Annual Sum or Average | 0.946694E+09 | |||
Minimum of Months | 19086315.32 | 2349.03 | 18.10 | |
Maximum of Months | 0.464734E+09 | 3962.58 | 30.07 |
Report: ZoneHeatingSummaryMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.114689E+09 | 6164.12 | 17-JAN-06:03 | 10.70 |
February | 25420283.94 | 5409.36 | 01-FEB-06:02 | 7.75 |
March | 23741633.19 | 3620.30 | 04-MAR-06:03 | 16.17 |
April | 21335935.03 | 3441.76 | 28-APR-04:02 | 27.93 |
May | 23796099.49 | 3831.91 | 18-MAY-04:02 | 30.20 |
June | 32232453.93 | 4243.53 | 22-JUN-04:02 | 30.28 |
July | 40613872.86 | 4733.55 | 12-JUL-04:02 | 29.25 |
August | 36478351.17 | 4999.19 | 25-AUG-04:02 | 29.07 |
September | 33918737.05 | 4794.01 | 12-SEP-04:02 | 26.75 |
October | 38369443.68 | 4462.92 | 11-OCT-04:02 | 24.15 |
November | 39609019.96 | 4292.27 | 14-NOV-05:03 | 14.07 |
December | 44821074.71 | 5823.75 | 11-DEC-06:02 | 9.72 |
Annual Sum or Average | 0.475026E+09 | |||
Minimum of Months | 21335935.03 | 3441.76 | 7.75 | |
Maximum of Months | 0.114689E+09 | 6164.12 | 30.28 |
Report: ZoneHeatingSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 7.83 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 9.73 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 15.55 |
April | 0.00 | 0.00 | 01-APR-00:10 | 23.70 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 30.53 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 28.05 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 32.95 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 28.43 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.58 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 17.72 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 12.50 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 7.83 | |
Maximum of Months | 0.00 | 0.00 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 41519494.01 | 19992.37 | 05-JAN-07:01 | 4.93 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 9.73 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 15.55 |
April | 0.00 | 0.00 | 01-APR-00:10 | 23.70 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 30.53 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 28.05 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 32.95 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 28.43 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.58 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 17.72 |
December | 762378.97 | 5082.53 | 23-DEC-07:03 | 6.25 |
Annual Sum or Average | 42281872.98 | |||
Minimum of Months | 0.00 | 0.00 | 4.93 | |
Maximum of Months | 41519494.01 | 19992.37 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.194172E+09 | 9064.31 | 02-JAN-06:01 | 6.45 |
February | 22488812.77 | 8096.25 | 04-FEB-07:03 | 8.40 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 15.55 |
April | 0.00 | 0.00 | 01-APR-00:10 | 23.70 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 30.53 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 28.05 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 32.95 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 28.43 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.58 |
November | 838216.03 | 3976.82 | 27-NOV-07:02 | 10.02 |
December | 58457983.06 | 8187.75 | 12-DEC-07:03 | 11.27 |
Annual Sum or Average | 0.275957E+09 | |||
Minimum of Months | 0.00 | 0.00 | 6.45 | |
Maximum of Months | 0.194172E+09 | 9064.31 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 80822300.66 | 5772.78 | 02-JAN-06:01 | 6.45 |
February | 8517671.59 | 5353.72 | 11-FEB-07:03 | 9.97 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 15.55 |
April | 0.00 | 0.00 | 01-APR-00:10 | 23.70 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 30.53 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 28.05 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 32.95 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 28.43 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.58 |
November | 498074.98 | 2637.85 | 27-NOV-07:02 | 10.02 |
December | 25363335.21 | 5350.39 | 18-DEC-07:02 | 14.13 |
Annual Sum or Average | 0.115201E+09 | |||
Minimum of Months | 0.00 | 0.00 | 6.45 | |
Maximum of Months | 80822300.66 | 5772.78 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.100480E+09 | 8834.03 | 02-JAN-06:01 | 6.45 |
February | 11967854.29 | 8179.82 | 04-FEB-07:03 | 8.40 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 15.55 |
April | 0.00 | 0.00 | 01-APR-00:10 | 23.70 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 30.53 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 28.05 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 32.95 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 28.43 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.58 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 17.72 |
December | 26329042.72 | 8073.75 | 22-DEC-07:03 | 14.30 |
Annual Sum or Average | 0.138777E+09 | |||
Minimum of Months | 0.00 | 0.00 | 6.45 | |
Maximum of Months | 0.100480E+09 | 8834.03 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.118709E+09 | 5627.49 | 02-JAN-06:01 | 6.45 |
February | 15019872.50 | 5333.96 | 04-FEB-07:03 | 8.40 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 15.55 |
April | 0.00 | 0.00 | 01-APR-00:10 | 23.70 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 30.53 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 28.05 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 32.95 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 28.43 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.58 |
November | 872981.06 | 3144.99 | 27-NOV-07:02 | 10.02 |
December | 39786181.23 | 5340.07 | 18-DEC-07:02 | 14.13 |
Annual Sum or Average | 0.174388E+09 | |||
Minimum of Months | 0.00 | 0.00 | 6.45 | |
Maximum of Months | 0.118709E+09 | 5627.49 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 3255381.90 | 4804.31 | 02-JAN-07:03 | 6.78 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 9.73 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 15.55 |
April | 0.00 | 0.00 | 01-APR-00:10 | 23.70 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 30.53 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 28.05 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 32.95 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 28.43 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.58 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 17.72 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 12.50 |
Annual Sum or Average | 3255381.90 | |||
Minimum of Months | 0.00 | 0.00 | 6.78 | |
Maximum of Months | 3255381.90 | 4804.31 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 922267.04 | 2627.76 | 03-JAN-07:01 | 5.50 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 9.73 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 15.55 |
April | 0.00 | 0.00 | 01-APR-00:10 | 23.70 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 30.53 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 28.05 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 32.95 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 28.43 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.58 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 17.72 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 12.50 |
Annual Sum or Average | 922267.04 | |||
Minimum of Months | 0.00 | 0.00 | 5.50 | |
Maximum of Months | 922267.04 | 2627.76 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.391071E+09 | 5803.71 | 03-JAN-07:10 | 5.50 |
February | 0.269572E+09 | 5313.89 | 02-FEB-07:10 | 7.12 |
March | 58819300.63 | 4909.84 | 03-MAR-07:08 | 14.33 |
April | 0.00 | 0.00 | 01-APR-00:10 | 23.70 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 30.53 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 28.05 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 32.95 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 28.43 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.58 |
November | 67357373.77 | 4896.36 | 29-NOV-07:05 | 13.87 |
December | 0.300188E+09 | 5392.51 | 21-DEC-07:10 | 5.68 |
Annual Sum or Average | 0.108701E+10 | |||
Minimum of Months | 0.00 | 0.00 | 5.50 | |
Maximum of Months | 0.391071E+09 | 5803.71 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 1069043.62 | 2655.20 | 03-JAN-07:01 | 5.50 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 9.73 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 15.55 |
April | 0.00 | 0.00 | 01-APR-00:10 | 23.70 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 30.53 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 28.05 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 32.95 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 28.43 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.58 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 17.72 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 12.50 |
Annual Sum or Average | 1069043.62 | |||
Minimum of Months | 0.00 | 0.00 | 5.50 | |
Maximum of Months | 1069043.62 | 2655.20 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 13743732.97 | 5670.53 | 23-JAN-07:01 | 7.08 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 9.73 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 15.55 |
April | 0.00 | 0.00 | 01-APR-00:10 | 23.70 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 30.53 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 28.05 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 32.95 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 28.43 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.58 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 17.72 |
December | 484146.25 | 2685.44 | 23-DEC-07:03 | 6.25 |
Annual Sum or Average | 14227879.22 | |||
Minimum of Months | 0.00 | 0.00 | 6.25 | |
Maximum of Months | 13743732.97 | 5670.53 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 7331875.28 | 3787.96 | 09-JAN-07:01 | 7.57 |
February | 14353.96 | 95.69 | 11-FEB-07:03 | 9.97 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 15.55 |
April | 0.00 | 0.00 | 01-APR-00:10 | 23.70 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 30.53 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 28.05 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 32.95 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 28.43 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.58 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 17.72 |
December | 638134.65 | 2568.25 | 23-DEC-07:03 | 6.25 |
Annual Sum or Average | 7984363.89 | |||
Minimum of Months | 0.00 | 0.00 | 6.25 | |
Maximum of Months | 7331875.28 | 3787.96 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 5565473.99 | 5651.89 | 04-JAN-07:01 | 5.50 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 9.73 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 15.55 |
April | 0.00 | 0.00 | 01-APR-00:10 | 23.70 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 30.53 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 28.05 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 32.95 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 28.43 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.58 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 17.72 |
December | 70156.29 | 467.71 | 23-DEC-07:03 | 6.25 |
Annual Sum or Average | 5635630.28 | |||
Minimum of Months | 0.00 | 0.00 | 5.50 | |
Maximum of Months | 5565473.99 | 5651.89 | 32.95 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 9629324.54 | 3812.53 | 06-JAN-07:01 | 5.62 |
February | 106956.95 | 520.11 | 11-FEB-07:03 | 9.97 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 15.55 |
April | 0.00 | 0.00 | 01-APR-00:10 | 23.70 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 30.53 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 28.05 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 32.95 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 28.43 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.58 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 17.72 |
December | 714490.01 | 2798.16 | 23-DEC-07:03 | 6.25 |
Annual Sum or Average | 10450771.50 | |||
Minimum of Months | 0.00 | 0.00 | 5.62 | |
Maximum of Months | 9629324.54 | 3812.53 | 32.95 |
Report: ZoneElectricSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.529706E+10 | 5543.17 | 02-JAN-08:09 | 0.208150E+11 | 18520.31 | 02-JAN-08:09 |
February | 0.480483E+10 | 5543.17 | 01-FEB-08:09 | 0.188385E+11 | 18520.31 | 01-FEB-08:09 |
March | 0.570947E+10 | 5543.17 | 01-MAR-08:09 | 0.216654E+11 | 18520.31 | 01-MAR-08:09 |
April | 0.509972E+10 | 5543.17 | 03-APR-07:10 | 0.200796E+11 | 18520.31 | 03-APR-07:10 |
May | 0.550327E+10 | 5543.17 | 01-MAY-07:10 | 0.212402E+11 | 18520.31 | 01-MAY-07:10 |
June | 0.547666E+10 | 5543.17 | 01-JUN-07:10 | 0.208620E+11 | 18520.31 | 01-JUN-07:10 |
July | 0.512633E+10 | 5543.17 | 03-JUL-07:10 | 0.204550E+11 | 18520.31 | 03-JUL-07:10 |
August | 0.570947E+10 | 5543.17 | 01-AUG-07:10 | 0.216654E+11 | 18520.31 | 01-AUG-07:10 |
September | 0.509972E+10 | 5543.17 | 01-SEP-07:10 | 0.200739E+11 | 18520.31 | 01-SEP-07:10 |
October | 0.529706E+10 | 5543.17 | 02-OCT-07:10 | 0.208179E+11 | 18520.31 | 02-OCT-07:10 |
November | 0.523498E+10 | 5543.17 | 01-NOV-07:10 | 0.203773E+11 | 18520.31 | 01-NOV-07:10 |
December | 0.512633E+10 | 5543.17 | 01-DEC-08:09 | 0.204522E+11 | 18520.31 | 01-DEC-08:09 |
Annual Sum or Average | 0.634849E+11 | 0.247342E+12 | ||||
Minimum of Months | 0.480483E+10 | 5543.17 | 0.188385E+11 | 18520.31 | ||
Maximum of Months | 0.570947E+10 | 5543.17 | 0.216654E+11 | 18520.31 |
Report: ZoneElectricSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.529706E+10 | 5543.17 | 02-JAN-08:09 | 0.106609E+11 | 7143.44 | 02-JAN-08:09 |
February | 0.480483E+10 | 5543.17 | 01-FEB-08:09 | 0.964936E+10 | 7143.44 | 01-FEB-08:09 |
March | 0.570947E+10 | 5543.17 | 01-MAR-08:09 | 0.110552E+11 | 7143.44 | 01-MAR-08:09 |
April | 0.509972E+10 | 5543.17 | 03-APR-07:10 | 0.102966E+11 | 7143.44 | 03-APR-07:10 |
May | 0.550327E+10 | 5543.17 | 01-MAY-07:10 | 0.108580E+11 | 7143.44 | 01-MAY-07:10 |
June | 0.547666E+10 | 5543.17 | 01-JUN-07:10 | 0.106494E+11 | 7143.44 | 01-JUN-07:10 |
July | 0.512633E+10 | 5543.17 | 03-JUL-07:10 | 0.105023E+11 | 7143.44 | 03-JUL-07:10 |
August | 0.570947E+10 | 5543.17 | 01-AUG-07:10 | 0.110552E+11 | 7143.44 | 01-AUG-07:10 |
September | 0.509972E+10 | 5543.17 | 01-SEP-07:10 | 0.102908E+11 | 7143.44 | 01-SEP-07:10 |
October | 0.529706E+10 | 5543.17 | 02-OCT-07:10 | 0.106637E+11 | 7143.44 | 02-OCT-07:10 |
November | 0.523498E+10 | 5543.17 | 01-NOV-07:10 | 0.104194E+11 | 7143.44 | 01-NOV-07:10 |
December | 0.512633E+10 | 5543.17 | 01-DEC-08:09 | 0.104994E+11 | 7143.44 | 01-DEC-08:09 |
Annual Sum or Average | 0.634849E+11 | 0.126600E+12 | ||||
Minimum of Months | 0.480483E+10 | 5543.17 | 0.964936E+10 | 7143.44 | ||
Maximum of Months | 0.570947E+10 | 5543.17 | 0.110552E+11 | 7143.44 |
Report: ZoneElectricSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.529706E+10 | 5543.17 | 02-JAN-08:09 | 0.106609E+11 | 7143.44 | 02-JAN-08:09 |
February | 0.480483E+10 | 5543.17 | 01-FEB-08:09 | 0.964936E+10 | 7143.44 | 01-FEB-08:09 |
March | 0.570947E+10 | 5543.17 | 01-MAR-08:09 | 0.110552E+11 | 7143.44 | 01-MAR-08:09 |
April | 0.509972E+10 | 5543.17 | 03-APR-07:10 | 0.102966E+11 | 7143.44 | 03-APR-07:10 |
May | 0.550327E+10 | 5543.17 | 01-MAY-07:10 | 0.108580E+11 | 7143.44 | 01-MAY-07:10 |
June | 0.547666E+10 | 5543.17 | 01-JUN-07:10 | 0.106494E+11 | 7143.44 | 01-JUN-07:10 |
July | 0.512633E+10 | 5543.17 | 03-JUL-07:10 | 0.105023E+11 | 7143.44 | 03-JUL-07:10 |
August | 0.570947E+10 | 5543.17 | 01-AUG-07:10 | 0.110552E+11 | 7143.44 | 01-AUG-07:10 |
September | 0.509972E+10 | 5543.17 | 01-SEP-07:10 | 0.102908E+11 | 7143.44 | 01-SEP-07:10 |
October | 0.529706E+10 | 5543.17 | 02-OCT-07:10 | 0.106637E+11 | 7143.44 | 02-OCT-07:10 |
November | 0.523498E+10 | 5543.17 | 01-NOV-07:10 | 0.104194E+11 | 7143.44 | 01-NOV-07:10 |
December | 0.512633E+10 | 5543.17 | 01-DEC-08:09 | 0.104994E+11 | 7143.44 | 01-DEC-08:09 |
Annual Sum or Average | 0.634849E+11 | 0.126600E+12 | ||||
Minimum of Months | 0.480483E+10 | 5543.17 | 0.964936E+10 | 7143.44 | ||
Maximum of Months | 0.570947E+10 | 5543.17 | 0.110552E+11 | 7143.44 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.797022E+09 | 1011.68 | 18-JAN-08:09 | 0.224739E+10 | 1505.89 | 02-JAN-08:09 |
February | 0.709709E+09 | 995.21 | 10-FEB-08:09 | 0.203416E+10 | 1505.89 | 01-FEB-08:09 |
March | 0.820848E+09 | 1003.25 | 14-MAR-07:10 | 0.233052E+10 | 1505.89 | 01-MAR-08:09 |
April | 0.725568E+09 | 720.41 | 03-APR-07:10 | 0.217059E+10 | 1505.89 | 03-APR-07:10 |
May | 0.772696E+09 | 829.72 | 24-MAY-07:10 | 0.228896E+10 | 1505.89 | 01-MAY-07:10 |
June | 0.768563E+09 | 823.43 | 23-JUN-07:10 | 0.224498E+10 | 1505.89 | 01-JUN-07:10 |
July | 0.728544E+09 | 972.27 | 26-JUL-07:10 | 0.221396E+10 | 1505.89 | 03-JUL-07:10 |
August | 0.814757E+09 | 996.58 | 16-AUG-07:10 | 0.233052E+10 | 1505.89 | 01-AUG-07:10 |
September | 0.736844E+09 | 1020.92 | 08-SEP-07:10 | 0.216939E+10 | 1505.89 | 01-SEP-07:10 |
October | 0.777006E+09 | 1064.20 | 11-OCT-07:10 | 0.224800E+10 | 1505.89 | 02-OCT-07:10 |
November | 0.784770E+09 | 1046.42 | 27-NOV-16:00 | 0.219649E+10 | 1505.89 | 01-NOV-07:10 |
December | 0.778944E+09 | 1052.38 | 29-DEC-16:00 | 0.221336E+10 | 1505.89 | 01-DEC-08:09 |
Annual Sum or Average | 0.921527E+10 | 0.266883E+11 | ||||
Minimum of Months | 0.709709E+09 | 720.41 | 0.203416E+10 | 1505.89 | ||
Maximum of Months | 0.820848E+09 | 1064.20 | 0.233052E+10 | 1505.89 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.501711E+09 | 635.94 | 17-JAN-16:00 | 0.142270E+10 | 953.30 | 02-JAN-08:09 |
February | 0.448581E+09 | 632.37 | 09-FEB-16:00 | 0.128771E+10 | 953.30 | 01-FEB-08:09 |
March | 0.519022E+09 | 592.14 | 14-MAR-07:10 | 0.147532E+10 | 953.30 | 01-MAR-08:09 |
April | 0.459713E+09 | 456.08 | 03-APR-07:10 | 0.137408E+10 | 953.30 | 03-APR-07:10 |
May | 0.490774E+09 | 456.08 | 01-MAY-07:10 | 0.144901E+10 | 953.30 | 01-MAY-07:10 |
June | 0.488063E+09 | 456.08 | 01-JUN-07:10 | 0.142117E+10 | 953.30 | 01-JUN-07:10 |
July | 0.461602E+09 | 598.66 | 26-JUL-07:10 | 0.140153E+10 | 953.30 | 03-JUL-07:10 |
August | 0.515556E+09 | 615.67 | 16-AUG-07:10 | 0.147532E+10 | 953.30 | 01-AUG-07:10 |
September | 0.466253E+09 | 632.76 | 07-SEP-07:10 | 0.137332E+10 | 953.30 | 01-SEP-07:10 |
October | 0.489905E+09 | 665.16 | 11-OCT-07:10 | 0.142308E+10 | 953.30 | 02-OCT-07:10 |
November | 0.495898E+09 | 673.61 | 27-NOV-16:00 | 0.139048E+10 | 953.30 | 01-NOV-07:10 |
December | 0.490685E+09 | 670.02 | 29-DEC-16:00 | 0.140115E+10 | 953.30 | 01-DEC-08:09 |
Annual Sum or Average | 0.582776E+10 | 0.168949E+11 | ||||
Minimum of Months | 0.448581E+09 | 456.08 | 0.128771E+10 | 953.30 | ||
Maximum of Months | 0.519022E+09 | 673.61 | 0.147532E+10 | 953.30 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.781525E+09 | 981.20 | 18-JAN-08:09 | 0.224738E+10 | 1505.88 | 02-JAN-08:09 |
February | 0.702260E+09 | 970.11 | 10-FEB-08:09 | 0.203415E+10 | 1505.88 | 01-FEB-08:09 |
March | 0.818302E+09 | 994.04 | 14-MAR-07:10 | 0.233050E+10 | 1505.88 | 01-MAR-08:09 |
April | 0.726454E+09 | 720.41 | 03-APR-07:10 | 0.217058E+10 | 1505.88 | 03-APR-07:10 |
May | 0.776294E+09 | 855.62 | 24-MAY-07:10 | 0.228894E+10 | 1505.88 | 01-MAY-07:10 |
June | 0.771724E+09 | 861.72 | 23-JUN-07:10 | 0.224497E+10 | 1505.88 | 01-JUN-07:10 |
July | 0.731191E+09 | 983.47 | 26-JUL-07:10 | 0.221395E+10 | 1505.88 | 03-JUL-07:10 |
August | 0.816180E+09 | 1001.53 | 16-AUG-07:10 | 0.233050E+10 | 1505.88 | 01-AUG-07:10 |
September | 0.736096E+09 | 1019.45 | 08-SEP-07:10 | 0.216937E+10 | 1505.88 | 01-SEP-07:10 |
October | 0.770884E+09 | 1059.90 | 11-OCT-07:10 | 0.224798E+10 | 1505.88 | 02-OCT-07:10 |
November | 0.771393E+09 | 982.33 | 27-NOV-16:00 | 0.219648E+10 | 1505.88 | 01-NOV-07:10 |
December | 0.761400E+09 | 1024.12 | 29-DEC-16:00 | 0.221335E+10 | 1505.88 | 01-DEC-08:09 |
Annual Sum or Average | 0.916370E+10 | 0.266882E+11 | ||||
Minimum of Months | 0.702260E+09 | 720.41 | 0.203415E+10 | 1505.88 | ||
Maximum of Months | 0.818302E+09 | 1059.90 | 0.233050E+10 | 1505.88 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.499717E+09 | 644.00 | 18-JAN-08:09 | 0.142269E+10 | 953.29 | 02-JAN-08:09 |
February | 0.446248E+09 | 635.47 | 10-FEB-08:09 | 0.128770E+10 | 953.29 | 01-FEB-08:09 |
March | 0.520054E+09 | 651.04 | 14-MAR-07:10 | 0.147531E+10 | 953.29 | 01-MAR-08:09 |
April | 0.459910E+09 | 556.96 | 03-APR-07:10 | 0.137407E+10 | 953.29 | 03-APR-07:10 |
May | 0.491180E+09 | 564.61 | 24-MAY-07:10 | 0.144900E+10 | 953.29 | 01-MAY-07:10 |
June | 0.487787E+09 | 565.50 | 23-JUN-07:10 | 0.142116E+10 | 953.29 | 01-JUN-07:10 |
July | 0.462756E+09 | 628.58 | 26-JUL-07:10 | 0.140153E+10 | 953.29 | 03-JUL-07:10 |
August | 0.517615E+09 | 640.36 | 16-AUG-07:10 | 0.147531E+10 | 953.29 | 01-AUG-07:10 |
September | 0.467266E+09 | 652.30 | 08-SEP-07:10 | 0.137331E+10 | 953.29 | 01-SEP-07:10 |
October | 0.492659E+09 | 676.08 | 11-OCT-07:10 | 0.142307E+10 | 953.29 | 02-OCT-07:10 |
November | 0.490961E+09 | 625.81 | 03-NOV-07:10 | 0.139047E+10 | 953.29 | 01-NOV-07:10 |
December | 0.485369E+09 | 638.26 | 29-DEC-16:00 | 0.140114E+10 | 953.29 | 01-DEC-08:09 |
Annual Sum or Average | 0.582152E+10 | 0.168948E+11 | ||||
Minimum of Months | 0.446248E+09 | 556.96 | 0.128770E+10 | 953.29 | ||
Maximum of Months | 0.520054E+09 | 676.08 | 0.147531E+10 | 953.29 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.795322E+09 | 1004.81 | 18-JAN-08:09 | 0.224739E+10 | 1505.89 | 02-JAN-08:09 |
February | 0.708591E+09 | 987.64 | 10-FEB-08:09 | 0.203416E+10 | 1505.89 | 01-FEB-08:09 |
March | 0.819888E+09 | 995.76 | 14-MAR-07:10 | 0.233052E+10 | 1505.89 | 01-MAR-08:09 |
April | 0.725222E+09 | 720.41 | 03-APR-07:10 | 0.217059E+10 | 1505.89 | 03-APR-07:10 |
May | 0.772314E+09 | 814.51 | 24-MAY-07:10 | 0.228896E+10 | 1505.89 | 01-MAY-07:10 |
June | 0.768090E+09 | 807.88 | 23-JUN-07:10 | 0.224498E+10 | 1505.89 | 01-JUN-07:10 |
July | 0.727624E+09 | 963.63 | 26-JUL-07:10 | 0.221396E+10 | 1505.89 | 03-JUL-07:10 |
August | 0.813919E+09 | 989.03 | 16-AUG-07:10 | 0.233052E+10 | 1505.89 | 01-AUG-07:10 |
September | 0.736134E+09 | 1014.47 | 08-SEP-07:10 | 0.216939E+10 | 1505.89 | 01-SEP-07:10 |
October | 0.775788E+09 | 1059.67 | 11-OCT-07:10 | 0.224800E+10 | 1505.89 | 02-OCT-07:10 |
November | 0.783268E+09 | 1040.71 | 27-NOV-16:00 | 0.219649E+10 | 1505.89 | 01-NOV-07:10 |
December | 0.776888E+09 | 1047.23 | 29-DEC-16:00 | 0.221336E+10 | 1505.89 | 01-DEC-08:09 |
Annual Sum or Average | 0.920305E+10 | 0.266883E+11 | ||||
Minimum of Months | 0.708591E+09 | 720.41 | 0.203416E+10 | 1505.89 | ||
Maximum of Months | 0.819888E+09 | 1059.67 | 0.233052E+10 | 1505.89 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.500951E+09 | 632.35 | 17-JAN-16:00 | 0.142270E+10 | 953.30 | 02-JAN-08:09 |
February | 0.447870E+09 | 628.73 | 09-FEB-16:00 | 0.128771E+10 | 953.30 | 01-FEB-08:09 |
March | 0.518604E+09 | 585.52 | 14-MAR-07:10 | 0.147532E+10 | 953.30 | 01-MAR-08:09 |
April | 0.459145E+09 | 456.08 | 03-APR-07:10 | 0.137408E+10 | 953.30 | 03-APR-07:10 |
May | 0.490531E+09 | 456.08 | 01-MAY-07:10 | 0.144901E+10 | 953.30 | 01-MAY-07:10 |
June | 0.487764E+09 | 456.08 | 01-JUN-07:10 | 0.142117E+10 | 953.30 | 01-JUN-07:10 |
July | 0.461254E+09 | 593.84 | 26-JUL-07:10 | 0.140153E+10 | 953.30 | 03-JUL-07:10 |
August | 0.515173E+09 | 611.14 | 16-AUG-07:10 | 0.147532E+10 | 953.30 | 01-AUG-07:10 |
September | 0.465867E+09 | 628.77 | 07-SEP-07:10 | 0.137332E+10 | 953.30 | 01-SEP-07:10 |
October | 0.489541E+09 | 662.50 | 11-OCT-07:10 | 0.142308E+10 | 953.30 | 02-OCT-07:10 |
November | 0.495153E+09 | 671.26 | 27-NOV-16:00 | 0.139048E+10 | 953.30 | 01-NOV-07:10 |
December | 0.489834E+09 | 667.63 | 29-DEC-16:00 | 0.140115E+10 | 953.30 | 01-DEC-08:09 |
Annual Sum or Average | 0.582169E+10 | 0.168949E+11 | ||||
Minimum of Months | 0.447870E+09 | 456.08 | 0.128771E+10 | 953.30 | ||
Maximum of Months | 0.518604E+09 | 671.26 | 0.147532E+10 | 953.30 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.781034E+09 | 972.63 | 18-JAN-08:09 | 0.224738E+10 | 1505.88 | 02-JAN-08:09 |
February | 0.701736E+09 | 961.25 | 10-FEB-08:09 | 0.203415E+10 | 1505.88 | 01-FEB-08:09 |
March | 0.817564E+09 | 986.02 | 14-MAR-07:10 | 0.233050E+10 | 1505.88 | 01-MAR-08:09 |
April | 0.726008E+09 | 720.41 | 03-APR-07:10 | 0.217058E+10 | 1505.88 | 03-APR-07:10 |
May | 0.775719E+09 | 841.80 | 24-MAY-07:10 | 0.228894E+10 | 1505.88 | 01-MAY-07:10 |
June | 0.771069E+09 | 848.21 | 23-JUN-07:10 | 0.224497E+10 | 1505.88 | 01-JUN-07:10 |
July | 0.730261E+09 | 975.43 | 26-JUL-07:10 | 0.221395E+10 | 1505.88 | 03-JUL-07:10 |
August | 0.815173E+09 | 994.25 | 16-AUG-07:10 | 0.233050E+10 | 1505.88 | 01-AUG-07:10 |
September | 0.735473E+09 | 1012.91 | 08-SEP-07:10 | 0.216937E+10 | 1505.88 | 01-SEP-07:10 |
October | 0.770439E+09 | 1055.12 | 11-OCT-07:10 | 0.224798E+10 | 1505.88 | 02-OCT-07:10 |
November | 0.770772E+09 | 972.03 | 27-NOV-16:00 | 0.219648E+10 | 1505.88 | 01-NOV-07:10 |
December | 0.760834E+09 | 1017.00 | 29-DEC-16:00 | 0.221335E+10 | 1505.88 | 01-DEC-08:09 |
Annual Sum or Average | 0.915608E+10 | 0.266882E+11 | ||||
Minimum of Months | 0.701736E+09 | 720.41 | 0.203415E+10 | 1505.88 | ||
Maximum of Months | 0.817564E+09 | 1055.12 | 0.233050E+10 | 1505.88 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.498835E+09 | 640.74 | 18-JAN-08:09 | 0.142269E+10 | 953.29 | 02-JAN-08:09 |
February | 0.445750E+09 | 631.94 | 10-FEB-08:09 | 0.128770E+10 | 953.29 | 01-FEB-08:09 |
March | 0.519599E+09 | 648.03 | 14-MAR-07:10 | 0.147531E+10 | 953.29 | 01-MAR-08:09 |
April | 0.459535E+09 | 549.91 | 03-APR-07:10 | 0.137407E+10 | 953.29 | 03-APR-07:10 |
May | 0.490742E+09 | 558.71 | 24-MAY-07:10 | 0.144900E+10 | 953.29 | 01-MAY-07:10 |
June | 0.487448E+09 | 559.62 | 23-JUN-07:10 | 0.142116E+10 | 953.29 | 01-JUN-07:10 |
July | 0.462246E+09 | 624.84 | 26-JUL-07:10 | 0.140153E+10 | 953.29 | 03-JUL-07:10 |
August | 0.516856E+09 | 637.02 | 16-AUG-07:10 | 0.147531E+10 | 953.29 | 01-AUG-07:10 |
September | 0.466711E+09 | 649.37 | 08-SEP-07:10 | 0.137331E+10 | 953.29 | 01-SEP-07:10 |
October | 0.492170E+09 | 673.94 | 11-OCT-07:10 | 0.142307E+10 | 953.29 | 02-OCT-07:10 |
November | 0.490364E+09 | 621.40 | 03-NOV-07:10 | 0.139047E+10 | 953.29 | 01-NOV-07:10 |
December | 0.484746E+09 | 633.86 | 29-DEC-16:00 | 0.140114E+10 | 953.29 | 01-DEC-08:09 |
Annual Sum or Average | 0.581500E+10 | 0.168948E+11 | ||||
Minimum of Months | 0.445750E+09 | 549.91 | 0.128770E+10 | 953.29 | ||
Maximum of Months | 0.519599E+09 | 673.94 | 0.147531E+10 | 953.29 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.797022E+09 | 1011.67 | 18-JAN-08:09 | 0.224739E+10 | 1505.89 | 02-JAN-08:09 |
February | 0.709708E+09 | 995.20 | 10-FEB-08:09 | 0.203416E+10 | 1505.89 | 01-FEB-08:09 |
March | 0.820848E+09 | 1003.24 | 14-MAR-07:10 | 0.233052E+10 | 1505.89 | 01-MAR-08:09 |
April | 0.725568E+09 | 720.41 | 03-APR-07:10 | 0.217059E+10 | 1505.89 | 03-APR-07:10 |
May | 0.772695E+09 | 829.70 | 24-MAY-07:10 | 0.228896E+10 | 1505.89 | 01-MAY-07:10 |
June | 0.768563E+09 | 823.41 | 23-JUN-07:10 | 0.224498E+10 | 1505.89 | 01-JUN-07:10 |
July | 0.728543E+09 | 972.26 | 26-JUL-07:10 | 0.221396E+10 | 1505.89 | 03-JUL-07:10 |
August | 0.814756E+09 | 996.57 | 16-AUG-07:10 | 0.233052E+10 | 1505.89 | 01-AUG-07:10 |
September | 0.736844E+09 | 1020.91 | 08-SEP-07:10 | 0.216939E+10 | 1505.89 | 01-SEP-07:10 |
October | 0.777005E+09 | 1064.19 | 11-OCT-07:10 | 0.224800E+10 | 1505.89 | 02-OCT-07:10 |
November | 0.784770E+09 | 1046.41 | 27-NOV-16:00 | 0.219649E+10 | 1505.89 | 01-NOV-07:10 |
December | 0.778944E+09 | 1052.37 | 29-DEC-16:00 | 0.221336E+10 | 1505.89 | 01-DEC-08:09 |
Annual Sum or Average | 0.921527E+10 | 0.266883E+11 | ||||
Minimum of Months | 0.709708E+09 | 720.41 | 0.203416E+10 | 1505.89 | ||
Maximum of Months | 0.820848E+09 | 1064.19 | 0.233052E+10 | 1505.89 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.501711E+09 | 635.93 | 17-JAN-16:00 | 0.142270E+10 | 953.30 | 02-JAN-08:09 |
February | 0.448580E+09 | 632.36 | 09-FEB-16:00 | 0.128771E+10 | 953.30 | 01-FEB-08:09 |
March | 0.519022E+09 | 592.13 | 14-MAR-07:10 | 0.147532E+10 | 953.30 | 01-MAR-08:09 |
April | 0.459713E+09 | 456.08 | 03-APR-07:10 | 0.137408E+10 | 953.30 | 03-APR-07:10 |
May | 0.490774E+09 | 456.08 | 01-MAY-07:10 | 0.144901E+10 | 953.30 | 01-MAY-07:10 |
June | 0.488063E+09 | 456.08 | 01-JUN-07:10 | 0.142117E+10 | 953.30 | 01-JUN-07:10 |
July | 0.461601E+09 | 598.66 | 26-JUL-07:10 | 0.140153E+10 | 953.30 | 03-JUL-07:10 |
August | 0.515556E+09 | 615.66 | 16-AUG-07:10 | 0.147532E+10 | 953.30 | 01-AUG-07:10 |
September | 0.466252E+09 | 632.75 | 07-SEP-07:10 | 0.137332E+10 | 953.30 | 01-SEP-07:10 |
October | 0.489905E+09 | 665.16 | 11-OCT-07:10 | 0.142308E+10 | 953.30 | 02-OCT-07:10 |
November | 0.495898E+09 | 673.61 | 27-NOV-16:00 | 0.139048E+10 | 953.30 | 01-NOV-07:10 |
December | 0.490685E+09 | 670.02 | 29-DEC-16:00 | 0.140115E+10 | 953.30 | 01-DEC-08:09 |
Annual Sum or Average | 0.582776E+10 | 0.168949E+11 | ||||
Minimum of Months | 0.448580E+09 | 456.08 | 0.128771E+10 | 953.30 | ||
Maximum of Months | 0.519022E+09 | 673.61 | 0.147532E+10 | 953.30 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.781525E+09 | 981.19 | 18-JAN-08:09 | 0.224738E+10 | 1505.88 | 02-JAN-08:09 |
February | 0.702260E+09 | 970.09 | 10-FEB-08:09 | 0.203415E+10 | 1505.88 | 01-FEB-08:09 |
March | 0.818302E+09 | 994.03 | 14-MAR-07:10 | 0.233050E+10 | 1505.88 | 01-MAR-08:09 |
April | 0.726454E+09 | 720.41 | 03-APR-07:10 | 0.217058E+10 | 1505.88 | 03-APR-07:10 |
May | 0.776294E+09 | 855.60 | 24-MAY-07:10 | 0.228894E+10 | 1505.88 | 01-MAY-07:10 |
June | 0.771724E+09 | 861.70 | 23-JUN-07:10 | 0.224497E+10 | 1505.88 | 01-JUN-07:10 |
July | 0.731190E+09 | 983.46 | 26-JUL-07:10 | 0.221395E+10 | 1505.88 | 03-JUL-07:10 |
August | 0.816179E+09 | 1001.52 | 16-AUG-07:10 | 0.233050E+10 | 1505.88 | 01-AUG-07:10 |
September | 0.736096E+09 | 1019.44 | 08-SEP-07:10 | 0.216937E+10 | 1505.88 | 01-SEP-07:10 |
October | 0.770884E+09 | 1059.89 | 11-OCT-07:10 | 0.224798E+10 | 1505.88 | 02-OCT-07:10 |
November | 0.771393E+09 | 982.33 | 27-NOV-16:00 | 0.219648E+10 | 1505.88 | 01-NOV-07:10 |
December | 0.761400E+09 | 1024.11 | 29-DEC-16:00 | 0.221335E+10 | 1505.88 | 01-DEC-08:09 |
Annual Sum or Average | 0.916370E+10 | 0.266882E+11 | ||||
Minimum of Months | 0.702260E+09 | 720.41 | 0.203415E+10 | 1505.88 | ||
Maximum of Months | 0.818302E+09 | 1059.89 | 0.233050E+10 | 1505.88 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.499717E+09 | 643.99 | 18-JAN-08:09 | 0.142269E+10 | 953.29 | 02-JAN-08:09 |
February | 0.446248E+09 | 635.46 | 10-FEB-08:09 | 0.128770E+10 | 953.29 | 01-FEB-08:09 |
March | 0.520054E+09 | 651.03 | 14-MAR-07:10 | 0.147531E+10 | 953.29 | 01-MAR-08:09 |
April | 0.459910E+09 | 556.95 | 03-APR-07:10 | 0.137407E+10 | 953.29 | 03-APR-07:10 |
May | 0.491180E+09 | 564.60 | 24-MAY-07:10 | 0.144900E+10 | 953.29 | 01-MAY-07:10 |
June | 0.487787E+09 | 565.48 | 23-JUN-07:10 | 0.142116E+10 | 953.29 | 01-JUN-07:10 |
July | 0.462756E+09 | 628.57 | 26-JUL-07:10 | 0.140153E+10 | 953.29 | 03-JUL-07:10 |
August | 0.517614E+09 | 640.36 | 16-AUG-07:10 | 0.147531E+10 | 953.29 | 01-AUG-07:10 |
September | 0.467265E+09 | 652.30 | 08-SEP-07:10 | 0.137331E+10 | 953.29 | 01-SEP-07:10 |
October | 0.492659E+09 | 676.07 | 11-OCT-07:10 | 0.142307E+10 | 953.29 | 02-OCT-07:10 |
November | 0.490961E+09 | 625.81 | 03-NOV-07:10 | 0.139047E+10 | 953.29 | 01-NOV-07:10 |
December | 0.485370E+09 | 638.25 | 29-DEC-16:00 | 0.140114E+10 | 953.29 | 01-DEC-08:09 |
Annual Sum or Average | 0.582152E+10 | 0.168948E+11 | ||||
Minimum of Months | 0.446248E+09 | 556.95 | 0.128770E+10 | 953.29 | ||
Maximum of Months | 0.520054E+09 | 676.07 | 0.147531E+10 | 953.29 |
Report: SpaceGainsMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.471610E+10 | 0.529706E+10 | 0.208150E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.427861E+10 | 0.480483E+10 | 0.188385E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.511242E+10 | 0.570947E+10 | 0.216654E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.453654E+10 | 0.509972E+10 | 0.200796E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.491426E+10 | 0.550327E+10 | 0.212402E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.490054E+10 | 0.547666E+10 | 0.208620E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.455026E+10 | 0.512633E+10 | 0.204550E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.511242E+10 | 0.570947E+10 | 0.216654E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.453654E+10 | 0.509972E+10 | 0.200739E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.471610E+10 | 0.529706E+10 | 0.208179E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.467005E+10 | 0.523498E+10 | 0.203773E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.455026E+10 | 0.512633E+10 | 0.204522E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.565941E+11 | 0.634849E+11 | 0.247342E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.427861E+10 | 0.480483E+10 | 0.188385E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.511242E+10 | 0.570947E+10 | 0.216654E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.471610E+10 | 0.529706E+10 | 0.106609E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.427861E+10 | 0.480483E+10 | 0.964936E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.511242E+10 | 0.570947E+10 | 0.110552E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.453654E+10 | 0.509972E+10 | 0.102966E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.491426E+10 | 0.550327E+10 | 0.108580E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.490054E+10 | 0.547666E+10 | 0.106494E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.455026E+10 | 0.512633E+10 | 0.105023E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.511242E+10 | 0.570947E+10 | 0.110552E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.453654E+10 | 0.509972E+10 | 0.102908E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.471610E+10 | 0.529706E+10 | 0.106637E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.467005E+10 | 0.523498E+10 | 0.104194E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.455026E+10 | 0.512633E+10 | 0.104994E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.565941E+11 | 0.634849E+11 | 0.126600E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.427861E+10 | 0.480483E+10 | 0.964936E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.511242E+10 | 0.570947E+10 | 0.110552E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.471610E+10 | 0.529706E+10 | 0.106609E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.427861E+10 | 0.480483E+10 | 0.964936E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.511242E+10 | 0.570947E+10 | 0.110552E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.453654E+10 | 0.509972E+10 | 0.102966E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.491426E+10 | 0.550327E+10 | 0.108580E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.490054E+10 | 0.547666E+10 | 0.106494E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.455026E+10 | 0.512633E+10 | 0.105023E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.511242E+10 | 0.570947E+10 | 0.110552E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.453654E+10 | 0.509972E+10 | 0.102908E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.471610E+10 | 0.529706E+10 | 0.106637E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.467005E+10 | 0.523498E+10 | 0.104194E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.455026E+10 | 0.512633E+10 | 0.104994E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.565941E+11 | 0.634849E+11 | 0.126600E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.427861E+10 | 0.480483E+10 | 0.964936E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.511242E+10 | 0.570947E+10 | 0.110552E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.797022E+09 | 0.224739E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65213.55 | 91485669.08 |
February | 0.901968E+09 | 0.709709E+09 | 0.203416E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2609269.18 | 0.100919E+09 |
March | 0.107774E+10 | 0.820848E+09 | 0.233052E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22757233.64 | 66959109.25 |
April | 0.956342E+09 | 0.725568E+09 | 0.217059E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 88306282.36 | 6063903.79 |
May | 0.103597E+10 | 0.772696E+09 | 0.228896E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.187142E+09 | 2482885.97 |
June | 0.103308E+10 | 0.768563E+09 | 0.224498E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.126588E+09 | 1279416.31 |
July | 0.959235E+09 | 0.728544E+09 | 0.221396E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.156500E+09 | 543863.10 |
August | 0.107774E+10 | 0.814757E+09 | 0.233052E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 88063331.56 | 971207.07 |
September | 0.956342E+09 | 0.736844E+09 | 0.216939E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 52638264.22 | 1886352.65 |
October | 0.994195E+09 | 0.777006E+09 | 0.224800E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29126829.29 | 5537712.56 |
November | 0.984487E+09 | 0.784770E+09 | 0.219649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7241995.72 | 20795121.68 |
December | 0.959235E+09 | 0.778944E+09 | 0.221336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 772505.12 | 83182448.58 |
Annual Sum or Average | 0.119305E+11 | 0.921527E+10 | 0.266883E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.761810E+09 | 0.382107E+09 |
Minimum of Months | 0.901968E+09 | 0.709709E+09 | 0.203416E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 65213.55 | 543863.10 |
Maximum of Months | 0.107774E+10 | 0.820848E+09 | 0.233052E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.187142E+09 | 0.100919E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629407E+09 | 0.501711E+09 | 0.142270E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4480.47 | 64227860.29 |
February | 0.571020E+09 | 0.448581E+09 | 0.128771E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1074391.43 | 71528983.67 |
March | 0.682301E+09 | 0.519022E+09 | 0.147532E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13774561.50 | 46480564.06 |
April | 0.605444E+09 | 0.459713E+09 | 0.137408E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57065000.68 | 4445892.71 |
May | 0.655854E+09 | 0.490774E+09 | 0.144901E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.123776E+09 | 1692064.18 |
June | 0.654023E+09 | 0.488063E+09 | 0.142117E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 84372134.68 | 862664.40 |
July | 0.607275E+09 | 0.461602E+09 | 0.140153E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.104363E+09 | 364428.37 |
August | 0.682301E+09 | 0.515556E+09 | 0.147532E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 58470304.10 | 646998.63 |
September | 0.605444E+09 | 0.466253E+09 | 0.137332E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34924459.87 | 1230959.41 |
October | 0.629407E+09 | 0.489905E+09 | 0.142308E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18238510.51 | 3970508.80 |
November | 0.623262E+09 | 0.495898E+09 | 0.139048E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4023032.64 | 15085140.07 |
December | 0.607275E+09 | 0.490685E+09 | 0.140115E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 247186.69 | 58917688.61 |
Annual Sum or Average | 0.755301E+10 | 0.582776E+10 | 0.168949E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.500333E+09 | 0.269454E+09 |
Minimum of Months | 0.571020E+09 | 0.448581E+09 | 0.128771E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4480.47 | 364428.37 |
Maximum of Months | 0.682301E+09 | 0.519022E+09 | 0.147532E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.123776E+09 | 71528983.67 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.781525E+09 | 0.224738E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.106294E+09 |
February | 0.901968E+09 | 0.702260E+09 | 0.203415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1069795.82 | 0.116909E+09 |
March | 0.107774E+10 | 0.818302E+09 | 0.233050E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19491089.86 | 72837406.23 |
April | 0.956342E+09 | 0.726454E+09 | 0.217058E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 86211856.89 | 6428876.41 |
May | 0.103597E+10 | 0.776294E+09 | 0.228894E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.187169E+09 | 2514275.04 |
June | 0.103308E+10 | 0.771724E+09 | 0.224497E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.126782E+09 | 1257604.34 |
July | 0.959235E+09 | 0.731191E+09 | 0.221395E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.156651E+09 | 544615.97 |
August | 0.107774E+10 | 0.816180E+09 | 0.233050E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 87709287.31 | 982408.71 |
September | 0.956342E+09 | 0.736096E+09 | 0.216937E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 51563608.99 | 1950320.61 |
October | 0.994195E+09 | 0.770884E+09 | 0.224798E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 26140184.77 | 6127020.24 |
November | 0.984487E+09 | 0.771393E+09 | 0.219648E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4720999.88 | 25272576.70 |
December | 0.959235E+09 | 0.761400E+09 | 0.221335E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19204.99 | 99851893.80 |
Annual Sum or Average | 0.119305E+11 | 0.916370E+10 | 0.266882E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.747527E+09 | 0.440970E+09 |
Minimum of Months | 0.901968E+09 | 0.702260E+09 | 0.203415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 544615.97 |
Maximum of Months | 0.107774E+10 | 0.818302E+09 | 0.233050E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.187169E+09 | 0.116909E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629366E+09 | 0.499717E+09 | 0.142269E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63552919.14 |
February | 0.570983E+09 | 0.446248E+09 | 0.128770E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1032774.88 | 70075163.12 |
March | 0.682256E+09 | 0.520054E+09 | 0.147531E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14055271.40 | 47367305.35 |
April | 0.605404E+09 | 0.459910E+09 | 0.137407E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 58122618.18 | 4409983.22 |
May | 0.655811E+09 | 0.491180E+09 | 0.144900E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124537E+09 | 1782479.29 |
June | 0.653980E+09 | 0.487787E+09 | 0.142116E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 84296344.94 | 902828.68 |
July | 0.607235E+09 | 0.462756E+09 | 0.140153E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.104641E+09 | 361765.28 |
August | 0.682256E+09 | 0.517615E+09 | 0.147531E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 58700840.38 | 649223.34 |
September | 0.605404E+09 | 0.467266E+09 | 0.137331E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34911046.83 | 1236956.34 |
October | 0.629366E+09 | 0.492659E+09 | 0.142307E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18872612.75 | 3713121.86 |
November | 0.623221E+09 | 0.490961E+09 | 0.139047E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4217034.04 | 14227679.26 |
December | 0.607235E+09 | 0.485369E+09 | 0.140114E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 240995.37 | 57504137.19 |
Annual Sum or Average | 0.755252E+10 | 0.582152E+10 | 0.168948E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.503627E+09 | 0.265784E+09 |
Minimum of Months | 0.570983E+09 | 0.446248E+09 | 0.128770E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 361765.28 |
Maximum of Months | 0.682256E+09 | 0.520054E+09 | 0.147531E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124537E+09 | 70075163.12 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.795322E+09 | 0.224739E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6278.85 | 57113382.20 |
February | 0.901968E+09 | 0.708591E+09 | 0.203416E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1432932.41 | 58971028.47 |
March | 0.107774E+10 | 0.819888E+09 | 0.233052E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13339156.96 | 35701876.22 |
April | 0.956342E+09 | 0.725222E+09 | 0.217059E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 49940662.56 | 2812855.73 |
May | 0.103597E+10 | 0.772314E+09 | 0.228896E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102761E+09 | 1000205.45 |
June | 0.103308E+10 | 0.768090E+09 | 0.224498E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 68481979.60 | 654726.46 |
July | 0.959235E+09 | 0.727624E+09 | 0.221396E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 84279977.32 | 340573.13 |
August | 0.107774E+10 | 0.813919E+09 | 0.233052E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 47379950.03 | 603174.95 |
September | 0.956342E+09 | 0.736134E+09 | 0.216939E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 28036828.92 | 1342036.54 |
October | 0.994195E+09 | 0.775788E+09 | 0.224800E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15679160.56 | 3490527.45 |
November | 0.984487E+09 | 0.783268E+09 | 0.219649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3572524.92 | 13056669.92 |
December | 0.959235E+09 | 0.776888E+09 | 0.221336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 198597.65 | 52831281.81 |
Annual Sum or Average | 0.119305E+11 | 0.920305E+10 | 0.266883E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.415109E+09 | 0.227918E+09 |
Minimum of Months | 0.901968E+09 | 0.708591E+09 | 0.203416E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6278.85 | 340573.13 |
Maximum of Months | 0.107774E+10 | 0.819888E+09 | 0.233052E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102761E+09 | 58971028.47 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629407E+09 | 0.500951E+09 | 0.142270E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40162801.84 |
February | 0.571020E+09 | 0.447870E+09 | 0.128771E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 560327.34 | 42146867.66 |
March | 0.682301E+09 | 0.518604E+09 | 0.147532E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7865204.99 | 25653156.49 |
April | 0.605444E+09 | 0.459145E+09 | 0.137408E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31339519.20 | 2242332.29 |
May | 0.655854E+09 | 0.490531E+09 | 0.144901E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 66580972.13 | 783524.96 |
June | 0.654023E+09 | 0.487764E+09 | 0.142117E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45139384.00 | 471526.20 |
July | 0.607275E+09 | 0.461254E+09 | 0.140153E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 55637600.03 | 240345.38 |
August | 0.682301E+09 | 0.515173E+09 | 0.147532E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31178616.78 | 420027.38 |
September | 0.605444E+09 | 0.465867E+09 | 0.137332E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18429139.46 | 922158.96 |
October | 0.629407E+09 | 0.489541E+09 | 0.142308E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9801808.57 | 2531892.68 |
November | 0.623262E+09 | 0.495153E+09 | 0.139048E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2026616.16 | 9378918.47 |
December | 0.607275E+09 | 0.489834E+09 | 0.140115E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 40668.13 | 37061759.48 |
Annual Sum or Average | 0.755301E+10 | 0.582169E+10 | 0.168949E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.268600E+09 | 0.162015E+09 |
Minimum of Months | 0.571020E+09 | 0.447870E+09 | 0.128771E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 240345.38 |
Maximum of Months | 0.682301E+09 | 0.518604E+09 | 0.147532E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 66580972.13 | 42146867.66 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.781034E+09 | 0.224738E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.280592E+10 |
February | 0.901968E+09 | 0.701736E+09 | 0.203415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 63889664.64 | 0.161151E+10 |
March | 0.107774E+10 | 0.817564E+09 | 0.233050E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.893918E+09 | 0.737071E+09 |
April | 0.956342E+09 | 0.726008E+09 | 0.217058E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.239251E+10 | 96085594.07 |
May | 0.103597E+10 | 0.775719E+09 | 0.228894E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.388096E+10 | 1466617.24 |
June | 0.103308E+10 | 0.771069E+09 | 0.224497E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.392120E+10 | 731734.60 |
July | 0.959235E+09 | 0.730261E+09 | 0.221395E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.270329E+10 | 362420.99 |
August | 0.107774E+10 | 0.815173E+09 | 0.233050E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.265592E+10 | 978108.12 |
September | 0.956342E+09 | 0.735473E+09 | 0.216937E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.195398E+10 | 4445200.41 |
October | 0.994195E+09 | 0.770439E+09 | 0.224798E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.136395E+10 | 0.320495E+09 |
November | 0.984487E+09 | 0.770772E+09 | 0.219648E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.433512E+09 | 0.101195E+10 |
December | 0.959235E+09 | 0.760834E+09 | 0.221335E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 659282.05 | 0.239446E+10 |
Annual Sum or Average | 0.119305E+11 | 0.915608E+10 | 0.266882E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.202638E+11 | 0.898547E+10 |
Minimum of Months | 0.901968E+09 | 0.701736E+09 | 0.203415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 362420.99 |
Maximum of Months | 0.107774E+10 | 0.817564E+09 | 0.233050E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.392120E+10 | 0.280592E+10 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629366E+09 | 0.498835E+09 | 0.142269E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39971152.84 |
February | 0.570983E+09 | 0.445750E+09 | 0.128770E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 517750.19 | 41727326.69 |
March | 0.682256E+09 | 0.519599E+09 | 0.147531E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7740025.44 | 26352850.91 |
April | 0.605404E+09 | 0.459535E+09 | 0.137407E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31439216.88 | 2306292.08 |
May | 0.655811E+09 | 0.490742E+09 | 0.144900E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 66481146.76 | 841508.21 |
June | 0.653980E+09 | 0.487448E+09 | 0.142116E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 44713600.44 | 527027.13 |
July | 0.607235E+09 | 0.462246E+09 | 0.140153E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 55486610.90 | 241906.37 |
August | 0.682256E+09 | 0.516856E+09 | 0.147531E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31106526.80 | 422489.55 |
September | 0.605404E+09 | 0.466711E+09 | 0.137331E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18267642.02 | 963512.19 |
October | 0.629366E+09 | 0.492170E+09 | 0.142307E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9896257.75 | 2451209.88 |
November | 0.623221E+09 | 0.490364E+09 | 0.139047E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2028337.92 | 9167376.17 |
December | 0.607235E+09 | 0.484746E+09 | 0.140114E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24292.11 | 36746487.82 |
Annual Sum or Average | 0.755252E+10 | 0.581500E+10 | 0.168948E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.267701E+09 | 0.161719E+09 |
Minimum of Months | 0.570983E+09 | 0.445750E+09 | 0.128770E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 241906.37 |
Maximum of Months | 0.682256E+09 | 0.519599E+09 | 0.147531E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 66481146.76 | 41727326.69 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.797022E+09 | 0.224739E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17516.58 | 86627643.09 |
February | 0.901968E+09 | 0.709708E+09 | 0.203416E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1893759.59 | 93456980.30 |
March | 0.107774E+10 | 0.820848E+09 | 0.233052E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19373141.18 | 60418383.65 |
April | 0.956342E+09 | 0.725568E+09 | 0.217059E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 74475094.74 | 5457274.25 |
May | 0.103597E+10 | 0.772695E+09 | 0.228896E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.156586E+09 | 1954482.11 |
June | 0.103308E+10 | 0.768563E+09 | 0.224498E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.105755E+09 | 1086760.88 |
July | 0.959235E+09 | 0.728543E+09 | 0.221396E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131041E+09 | 454803.76 |
August | 0.107774E+10 | 0.814756E+09 | 0.233052E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 74076080.13 | 802705.98 |
September | 0.956342E+09 | 0.736844E+09 | 0.216939E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 44057000.51 | 1684138.70 |
October | 0.994195E+09 | 0.777005E+09 | 0.224800E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24610123.84 | 5098076.13 |
November | 0.984487E+09 | 0.784770E+09 | 0.219649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5719430.22 | 19711485.42 |
December | 0.959235E+09 | 0.778944E+09 | 0.221336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 429947.06 | 78681734.41 |
Annual Sum or Average | 0.119305E+11 | 0.921527E+10 | 0.266883E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.638034E+09 | 0.355434E+09 |
Minimum of Months | 0.901968E+09 | 0.709708E+09 | 0.203416E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17516.58 | 454803.76 |
Maximum of Months | 0.107774E+10 | 0.820848E+09 | 0.233052E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.156586E+09 | 93456980.30 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.465148E+09 | 0.501711E+09 | 0.142270E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 59626572.84 |
February | 0.421807E+09 | 0.448580E+09 | 0.128771E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 838207.34 | 65038828.04 |
March | 0.502994E+09 | 0.519022E+09 | 0.147532E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11846365.26 | 41458425.19 |
April | 0.447140E+09 | 0.459713E+09 | 0.137408E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48229111.70 | 3925503.12 |
May | 0.484071E+09 | 0.490774E+09 | 0.144901E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103626E+09 | 1326049.68 |
June | 0.482240E+09 | 0.488063E+09 | 0.142117E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 70501407.98 | 731718.97 |
July | 0.448971E+09 | 0.461601E+09 | 0.140153E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 87358102.91 | 303344.00 |
August | 0.502994E+09 | 0.515556E+09 | 0.147532E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 49130976.41 | 533036.19 |
September | 0.447140E+09 | 0.466252E+09 | 0.137332E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29230600.43 | 1096943.74 |
October | 0.465148E+09 | 0.489905E+09 | 0.142308E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15420964.02 | 3604463.99 |
November | 0.460569E+09 | 0.495898E+09 | 0.139048E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3296240.41 | 13944417.40 |
December | 0.448971E+09 | 0.490685E+09 | 0.140115E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 131043.06 | 54602593.46 |
Annual Sum or Average | 0.557719E+10 | 0.582776E+10 | 0.168949E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.419609E+09 | 0.246192E+09 |
Minimum of Months | 0.421807E+09 | 0.448580E+09 | 0.128771E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 303344.00 |
Maximum of Months | 0.502994E+09 | 0.519022E+09 | 0.147532E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103626E+09 | 65038828.04 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.781525E+09 | 0.224738E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 96774977.51 |
February | 0.901968E+09 | 0.702260E+09 | 0.203415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 910530.02 | 0.105280E+09 |
March | 0.107774E+10 | 0.818302E+09 | 0.233050E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16445714.15 | 64982780.25 |
April | 0.956342E+09 | 0.726454E+09 | 0.217058E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 72309133.15 | 5745837.19 |
May | 0.103597E+10 | 0.776294E+09 | 0.228894E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.156470E+09 | 1982060.79 |
June | 0.103308E+10 | 0.771724E+09 | 0.224497E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.105890E+09 | 1065636.47 |
July | 0.959235E+09 | 0.731190E+09 | 0.221395E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131084E+09 | 455073.19 |
August | 0.107774E+10 | 0.816179E+09 | 0.233050E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 73659832.07 | 813159.06 |
September | 0.956342E+09 | 0.736096E+09 | 0.216937E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 43106137.20 | 1735797.43 |
October | 0.994195E+09 | 0.770884E+09 | 0.224798E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21833373.59 | 5556743.56 |
November | 0.984487E+09 | 0.771393E+09 | 0.219648E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3946608.74 | 22987160.78 |
December | 0.959235E+09 | 0.761400E+09 | 0.221335E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17109.47 | 90825577.83 |
Annual Sum or Average | 0.119305E+11 | 0.916370E+10 | 0.266882E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.625672E+09 | 0.398205E+09 |
Minimum of Months | 0.901968E+09 | 0.702260E+09 | 0.203415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 455073.19 |
Maximum of Months | 0.107774E+10 | 0.818302E+09 | 0.233050E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.156470E+09 | 0.105280E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629366E+09 | 0.499717E+09 | 0.142269E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 59424940.74 |
February | 0.570983E+09 | 0.446248E+09 | 0.128770E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 767576.05 | 64631254.98 |
March | 0.682256E+09 | 0.520054E+09 | 0.147531E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11740826.00 | 42625777.18 |
April | 0.605404E+09 | 0.459910E+09 | 0.137407E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48547163.74 | 3941349.94 |
May | 0.655811E+09 | 0.491180E+09 | 0.144900E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103732E+09 | 1406556.68 |
June | 0.653980E+09 | 0.487787E+09 | 0.142116E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 70053902.29 | 782066.48 |
July | 0.607235E+09 | 0.462756E+09 | 0.140153E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 87160659.33 | 302571.32 |
August | 0.682256E+09 | 0.517614E+09 | 0.147531E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 49124609.77 | 538881.42 |
September | 0.605404E+09 | 0.467265E+09 | 0.137331E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29020372.28 | 1119607.07 |
October | 0.629366E+09 | 0.492659E+09 | 0.142307E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15704232.38 | 3428904.79 |
November | 0.623221E+09 | 0.490961E+09 | 0.139047E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3313520.49 | 13483805.96 |
December | 0.607235E+09 | 0.485370E+09 | 0.140114E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 88538.37 | 53882291.78 |
Annual Sum or Average | 0.755252E+10 | 0.582152E+10 | 0.168948E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.419253E+09 | 0.245568E+09 |
Minimum of Months | 0.570983E+09 | 0.446248E+09 | 0.128770E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 302571.32 |
Maximum of Months | 0.682256E+09 | 0.520054E+09 | 0.147531E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103732E+09 | 64631254.98 |
Report: SpaceGainsMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.128095E+09 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 806425.72 | 0.136363E+09 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20063661.69 | 84929917.10 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 88359105.68 | 7092831.66 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.195365E+09 | 2275625.29 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131907E+09 | 1170631.01 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.165713E+09 | 517969.74 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 91408663.91 | 840481.62 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51712770.61 | 1631355.02 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26669808.95 | 7398899.71 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4561315.81 | 29604895.21 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16123.97 | 0.117224E+09 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.776583E+09 | 0.517144E+09 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 517969.74 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.195365E+09 | 0.136363E+09 |
Report: SpaceGainsMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.150254E+09 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1516636.67 | 0.165008E+09 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26490819.41 | 0.106669E+09 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.113617E+09 | 9161935.34 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.249821E+09 | 3089746.15 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.169975E+09 | 1588673.75 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.213072E+09 | 620278.47 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118072E+09 | 1031838.91 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67530498.56 | 1812310.08 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35548825.99 | 9037996.39 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6877591.95 | 35525365.98 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 387772.04 | 0.138653E+09 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.100291E+10 | 0.622452E+09 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 620278.47 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.249821E+09 | 0.165008E+09 |
Report: SpaceGainsMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.148158E+09 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 196344.69 | 0.163408E+09 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19158389.49 | 97290679.45 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109165E+09 | 6886073.82 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.259747E+09 | 2472262.93 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.177089E+09 | 1403577.52 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.217319E+09 | 517057.94 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.119771E+09 | 1373588.91 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67286630.25 | 1444230.41 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30926244.91 | 7138211.46 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3767046.68 | 32681659.75 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.132628E+09 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.100442E+10 | 0.595401E+09 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 517057.94 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.259747E+09 | 0.163408E+09 |
Report: PeakSpaceGainsMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 6198.29 | 02-JAN-10:09 | 5543.17 | 02-JAN-08:09 | 18520.31 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 6198.29 | 01-FEB-10:09 | 5543.17 | 01-FEB-08:09 | 18520.31 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 6198.29 | 01-MAR-10:09 | 5543.17 | 01-MAR-08:09 | 18520.31 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 6198.29 | 03-APR-09:09 | 5543.17 | 03-APR-07:10 | 18520.31 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 6198.29 | 01-MAY-09:09 | 5543.17 | 01-MAY-07:10 | 18520.31 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 6198.29 | 01-JUN-09:09 | 5543.17 | 01-JUN-07:10 | 18520.31 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 6198.29 | 03-JUL-09:09 | 5543.17 | 03-JUL-07:10 | 18520.31 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 6198.29 | 01-AUG-09:09 | 5543.17 | 01-AUG-07:10 | 18520.31 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 6198.29 | 01-SEP-09:09 | 5543.17 | 01-SEP-07:10 | 18520.31 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 6198.29 | 02-OCT-09:09 | 5543.17 | 02-OCT-07:10 | 18520.31 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 6198.29 | 01-NOV-09:09 | 5543.17 | 01-NOV-07:10 | 18520.31 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6198.29 | 01-DEC-10:09 | 5543.17 | 01-DEC-08:09 | 18520.31 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 6198.29 | 5543.17 | 18520.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 6198.29 | 5543.17 | 18520.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 6198.29 | 02-JAN-10:09 | 5543.17 | 02-JAN-08:09 | 7143.44 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 6198.29 | 01-FEB-10:09 | 5543.17 | 01-FEB-08:09 | 7143.44 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 6198.29 | 01-MAR-10:09 | 5543.17 | 01-MAR-08:09 | 7143.44 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 6198.29 | 03-APR-09:09 | 5543.17 | 03-APR-07:10 | 7143.44 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 6198.29 | 01-MAY-09:09 | 5543.17 | 01-MAY-07:10 | 7143.44 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 6198.29 | 01-JUN-09:09 | 5543.17 | 01-JUN-07:10 | 7143.44 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 6198.29 | 03-JUL-09:09 | 5543.17 | 03-JUL-07:10 | 7143.44 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 6198.29 | 01-AUG-09:09 | 5543.17 | 01-AUG-07:10 | 7143.44 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 6198.29 | 01-SEP-09:09 | 5543.17 | 01-SEP-07:10 | 7143.44 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 6198.29 | 02-OCT-09:09 | 5543.17 | 02-OCT-07:10 | 7143.44 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 6198.29 | 01-NOV-09:09 | 5543.17 | 01-NOV-07:10 | 7143.44 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6198.29 | 01-DEC-10:09 | 5543.17 | 01-DEC-08:09 | 7143.44 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 6198.29 | 5543.17 | 7143.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 6198.29 | 5543.17 | 7143.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 6198.29 | 02-JAN-10:09 | 5543.17 | 02-JAN-08:09 | 7143.44 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 6198.29 | 01-FEB-10:09 | 5543.17 | 01-FEB-08:09 | 7143.44 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 6198.29 | 01-MAR-10:09 | 5543.17 | 01-MAR-08:09 | 7143.44 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 6198.29 | 03-APR-09:09 | 5543.17 | 03-APR-07:10 | 7143.44 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 6198.29 | 01-MAY-09:09 | 5543.17 | 01-MAY-07:10 | 7143.44 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 6198.29 | 01-JUN-09:09 | 5543.17 | 01-JUN-07:10 | 7143.44 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 6198.29 | 03-JUL-09:09 | 5543.17 | 03-JUL-07:10 | 7143.44 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 6198.29 | 01-AUG-09:09 | 5543.17 | 01-AUG-07:10 | 7143.44 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 6198.29 | 01-SEP-09:09 | 5543.17 | 01-SEP-07:10 | 7143.44 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 6198.29 | 02-OCT-09:09 | 5543.17 | 02-OCT-07:10 | 7143.44 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 6198.29 | 01-NOV-09:09 | 5543.17 | 01-NOV-07:10 | 7143.44 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6198.29 | 01-DEC-10:09 | 5543.17 | 01-DEC-08:09 | 7143.44 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 6198.29 | 5543.17 | 7143.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 6198.29 | 5543.17 | 7143.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 1011.68 | 18-JAN-08:09 | 1505.89 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 14.37 | 08-JAN-15:00 | 237.62 | 15-JAN-17:00 |
February | 1306.65 | 01-FEB-10:09 | 995.21 | 10-FEB-08:09 | 1505.89 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 77.63 | 19-FEB-15:00 | 338.35 | 09-FEB-22:10 |
March | 1306.65 | 01-MAR-10:09 | 1003.25 | 14-MAR-07:10 | 1505.89 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 238.56 | 26-MAR-15:00 | 681.84 | 24-MAR-24:00 |
April | 1306.65 | 03-APR-09:09 | 720.41 | 03-APR-07:10 | 1505.89 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 431.91 | 15-APR-17:10 | 101.35 | 22-APR-18:20 |
May | 1306.65 | 01-MAY-09:09 | 829.72 | 24-MAY-07:10 | 1505.89 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 766.75 | 28-MAY-15:00 | 80.46 | 15-MAY-03:00 |
June | 1306.65 | 01-JUN-09:09 | 823.43 | 23-JUN-07:10 | 1505.89 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 361.39 | 17-JUN-20:50 | 63.44 | 18-JUN-05:00 |
July | 1306.65 | 03-JUL-09:09 | 972.27 | 26-JUL-07:10 | 1505.89 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 382.07 | 02-JUL-11:56 | 51.93 | 19-JUL-03:00 |
August | 1306.65 | 01-AUG-09:09 | 996.58 | 16-AUG-07:10 | 1505.89 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 251.32 | 06-AUG-14:06 | 62.37 | 15-AUG-24:00 |
September | 1306.65 | 01-SEP-09:09 | 1020.92 | 08-SEP-07:10 | 1505.89 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 210.38 | 24-SEP-14:46 | 25.12 | 19-SEP-05:00 |
October | 1306.65 | 02-OCT-09:09 | 1064.20 | 11-OCT-07:10 | 1505.89 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 247.74 | 15-OCT-12:10 | 101.49 | 12-OCT-03:00 |
November | 1306.65 | 01-NOV-09:09 | 1046.42 | 27-NOV-16:00 | 1505.89 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 92.53 | 12-NOV-14:10 | 163.60 | 28-NOV-05:03 |
December | 1306.65 | 01-DEC-10:09 | 1052.38 | 29-DEC-16:00 | 1505.89 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 71.02 | 24-DEC-13:53 | 372.49 | 29-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 720.41 | 1505.89 | 0.00 | 0.00 | 0.00 | 0.00 | 14.37 | 25.12 | |||||
Maximum of Months | 1306.65 | 1064.20 | 1505.89 | 0.00 | 0.00 | 0.00 | 0.00 | 766.75 | 681.84 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.22 | 02-JAN-10:09 | 635.94 | 17-JAN-16:00 | 953.30 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3.69 | 08-JAN-15:00 | 156.98 | 15-JAN-17:00 |
February | 827.22 | 01-FEB-10:09 | 632.37 | 09-FEB-16:00 | 953.30 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 36.36 | 19-FEB-14:50 | 220.50 | 09-FEB-22:10 |
March | 827.22 | 01-MAR-10:09 | 592.14 | 14-MAR-07:10 | 953.30 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 141.68 | 26-MAR-15:00 | 461.07 | 24-MAR-24:00 |
April | 827.22 | 03-APR-09:09 | 456.08 | 03-APR-07:10 | 953.30 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 289.58 | 15-APR-17:10 | 72.51 | 22-APR-18:20 |
May | 827.22 | 01-MAY-09:09 | 456.08 | 01-MAY-07:10 | 953.30 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 511.16 | 28-MAY-15:00 | 54.80 | 15-MAY-03:00 |
June | 827.22 | 01-JUN-09:09 | 456.08 | 01-JUN-07:10 | 953.30 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 246.17 | 17-JUN-20:50 | 41.86 | 18-JUN-05:00 |
July | 827.22 | 03-JUL-09:09 | 598.66 | 26-JUL-07:10 | 953.30 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 254.34 | 02-JUL-11:54 | 34.34 | 19-JUL-03:00 |
August | 827.22 | 01-AUG-09:09 | 615.67 | 16-AUG-07:10 | 953.30 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 169.24 | 06-AUG-14:06 | 41.84 | 15-AUG-24:00 |
September | 827.22 | 01-SEP-09:09 | 632.76 | 07-SEP-07:10 | 953.30 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 142.42 | 24-SEP-14:46 | 16.47 | 19-SEP-05:00 |
October | 827.22 | 02-OCT-09:09 | 665.16 | 11-OCT-07:10 | 953.30 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 158.17 | 15-OCT-11:56 | 67.02 | 12-OCT-03:00 |
November | 827.22 | 01-NOV-09:09 | 673.61 | 27-NOV-16:00 | 953.30 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 52.36 | 12-NOV-14:10 | 109.32 | 28-NOV-05:03 |
December | 827.22 | 01-DEC-10:09 | 670.02 | 29-DEC-16:00 | 953.30 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 32.90 | 24-DEC-14:20 | 246.03 | 29-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.22 | 456.08 | 953.30 | 0.00 | 0.00 | 0.00 | 0.00 | 3.69 | 16.47 | |||||
Maximum of Months | 827.22 | 673.61 | 953.30 | 0.00 | 0.00 | 0.00 | 0.00 | 511.16 | 461.07 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 981.20 | 18-JAN-08:09 | 1505.88 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 308.97 | 22-JAN-14:30 |
February | 1306.65 | 01-FEB-10:09 | 970.11 | 10-FEB-08:09 | 1505.88 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 15.86 | 21-FEB-15:00 | 339.64 | 09-FEB-22:10 |
March | 1306.65 | 01-MAR-10:09 | 994.04 | 14-MAR-07:10 | 1505.88 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 194.26 | 26-MAR-14:55 | 721.43 | 24-MAR-24:00 |
April | 1306.65 | 03-APR-09:09 | 720.41 | 03-APR-07:10 | 1505.88 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 434.07 | 15-APR-17:10 | 107.09 | 22-APR-18:20 |
May | 1306.65 | 01-MAY-09:09 | 855.62 | 24-MAY-07:10 | 1505.88 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 766.75 | 28-MAY-15:00 | 81.92 | 15-MAY-03:00 |
June | 1306.65 | 01-JUN-09:09 | 861.72 | 23-JUN-07:10 | 1505.88 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 364.13 | 17-JUN-20:50 | 63.02 | 18-JUN-05:00 |
July | 1306.65 | 03-JUL-09:09 | 983.47 | 26-JUL-07:10 | 1505.88 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 381.14 | 02-JUL-11:54 | 51.83 | 19-JUL-03:00 |
August | 1306.65 | 01-AUG-09:09 | 1001.53 | 16-AUG-07:10 | 1505.88 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 248.84 | 06-AUG-14:04 | 62.76 | 15-AUG-24:00 |
September | 1306.65 | 01-SEP-09:09 | 1019.45 | 08-SEP-07:10 | 1505.88 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 201.55 | 24-SEP-14:44 | 25.82 | 19-SEP-05:00 |
October | 1306.65 | 02-OCT-09:09 | 1059.90 | 11-OCT-07:10 | 1505.88 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 209.69 | 15-OCT-13:00 | 102.30 | 12-OCT-03:00 |
November | 1306.65 | 01-NOV-09:09 | 982.33 | 27-NOV-16:00 | 1505.88 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 42.30 | 12-NOV-14:45 | 171.25 | 28-NOV-05:03 |
December | 1306.65 | 01-DEC-10:09 | 1024.12 | 29-DEC-16:00 | 1505.88 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3.42 | 28-DEC-14:00 | 510.46 | 31-DEC-14:55 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 720.41 | 1505.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.82 | |||||
Maximum of Months | 1306.65 | 1059.90 | 1505.88 | 0.00 | 0.00 | 0.00 | 0.00 | 766.75 | 721.43 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.17 | 02-JAN-10:09 | 644.00 | 18-JAN-08:09 | 953.29 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 158.46 | 15-JAN-17:00 |
February | 827.17 | 01-FEB-10:09 | 635.47 | 10-FEB-08:09 | 953.29 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 28.80 | 19-FEB-13:43 | 218.59 | 09-FEB-22:10 |
March | 827.17 | 01-MAR-10:09 | 651.04 | 14-MAR-07:10 | 953.29 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 147.40 | 26-MAR-13:00 | 478.38 | 24-MAR-24:00 |
April | 827.17 | 03-APR-09:09 | 556.96 | 03-APR-07:10 | 953.29 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 287.07 | 15-APR-17:08 | 68.84 | 22-APR-18:20 |
May | 827.17 | 01-MAY-09:09 | 564.61 | 24-MAY-07:10 | 953.29 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 511.16 | 28-MAY-15:00 | 57.02 | 15-MAY-03:00 |
June | 827.17 | 01-JUN-09:09 | 565.50 | 23-JUN-07:10 | 953.29 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 242.50 | 17-JUN-20:37 | 43.66 | 18-JUN-05:00 |
July | 827.17 | 03-JUL-09:09 | 628.58 | 26-JUL-07:10 | 953.29 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 258.22 | 02-JUL-11:56 | 34.20 | 19-JUL-03:00 |
August | 827.17 | 01-AUG-09:09 | 640.36 | 16-AUG-07:10 | 953.29 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 171.24 | 06-AUG-09:30 | 42.16 | 15-AUG-24:00 |
September | 827.17 | 01-SEP-09:09 | 652.30 | 08-SEP-07:10 | 953.29 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 139.83 | 24-SEP-14:04 | 16.92 | 19-SEP-05:00 |
October | 827.17 | 02-OCT-09:09 | 676.08 | 11-OCT-07:10 | 953.29 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 173.73 | 15-OCT-12:02 | 67.00 | 12-OCT-03:00 |
November | 827.17 | 01-NOV-09:09 | 625.81 | 03-NOV-07:10 | 953.29 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 55.39 | 12-NOV-12:50 | 109.77 | 28-NOV-05:03 |
December | 827.17 | 01-DEC-10:09 | 638.26 | 29-DEC-16:00 | 953.29 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 32.01 | 24-DEC-13:43 | 244.76 | 29-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.17 | 556.96 | 953.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.92 | |||||
Maximum of Months | 827.17 | 676.08 | 953.29 | 0.00 | 0.00 | 0.00 | 0.00 | 511.16 | 478.38 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 1004.81 | 18-JAN-08:09 | 1505.89 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3.03 | 08-JAN-15:00 | 146.75 | 15-JAN-17:00 |
February | 1306.65 | 01-FEB-10:09 | 987.64 | 10-FEB-08:09 | 1505.89 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 47.18 | 19-FEB-15:10 | 199.23 | 09-FEB-22:10 |
March | 1306.65 | 01-MAR-10:09 | 995.76 | 14-MAR-07:10 | 1505.89 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 155.05 | 26-MAR-14:50 | 384.96 | 24-MAR-24:00 |
April | 1306.65 | 03-APR-09:09 | 720.41 | 03-APR-07:10 | 1505.89 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 246.74 | 15-APR-17:02 | 56.37 | 22-APR-18:20 |
May | 1306.65 | 01-MAY-09:09 | 814.51 | 24-MAY-07:10 | 1505.89 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 418.49 | 28-MAY-15:00 | 34.19 | 15-MAY-03:00 |
June | 1306.65 | 01-JUN-09:09 | 807.88 | 23-JUN-07:10 | 1505.89 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 203.22 | 17-JUN-21:00 | 34.04 | 18-JUN-05:00 |
July | 1306.65 | 03-JUL-09:09 | 963.63 | 26-JUL-07:10 | 1505.89 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 201.89 | 02-JUL-11:38 | 31.44 | 19-JUL-03:00 |
August | 1306.65 | 01-AUG-09:09 | 989.03 | 16-AUG-07:10 | 1505.89 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 132.21 | 06-AUG-14:28 | 35.51 | 15-AUG-24:00 |
September | 1306.65 | 01-SEP-09:09 | 1014.47 | 08-SEP-07:10 | 1505.89 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 112.60 | 24-SEP-14:35 | 19.20 | 08-SEP-22:10 |
October | 1306.65 | 02-OCT-09:09 | 1059.67 | 11-OCT-07:10 | 1505.89 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 133.22 | 15-OCT-12:50 | 63.60 | 12-OCT-03:00 |
November | 1306.65 | 01-NOV-09:09 | 1040.71 | 27-NOV-16:00 | 1505.89 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.22 | 12-NOV-13:52 | 104.37 | 28-NOV-05:00 |
December | 1306.65 | 01-DEC-10:09 | 1047.23 | 29-DEC-16:00 | 1505.89 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 25.12 | 24-DEC-13:53 | 234.75 | 29-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 720.41 | 1505.89 | 0.00 | 0.00 | 0.00 | 0.00 | 3.03 | 19.20 | |||||
Maximum of Months | 1306.65 | 1059.67 | 1505.89 | 0.00 | 0.00 | 0.00 | 0.00 | 418.49 | 384.96 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.22 | 02-JAN-10:09 | 632.35 | 17-JAN-16:00 | 953.30 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 98.86 | 15-JAN-17:00 |
February | 827.22 | 01-FEB-10:09 | 628.73 | 09-FEB-16:00 | 953.30 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 20.17 | 19-FEB-15:10 | 133.00 | 09-FEB-22:10 |
March | 827.22 | 01-MAR-10:09 | 585.52 | 14-MAR-07:10 | 953.30 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 88.00 | 26-MAR-15:10 | 270.97 | 24-MAR-24:00 |
April | 827.22 | 03-APR-09:09 | 456.08 | 03-APR-07:10 | 953.30 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 159.93 | 15-APR-17:02 | 42.82 | 22-APR-18:20 |
May | 827.22 | 01-MAY-09:09 | 456.08 | 01-MAY-07:10 | 953.30 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 276.87 | 28-MAY-14:45 | 26.90 | 15-MAY-03:00 |
June | 827.22 | 01-JUN-09:09 | 456.08 | 01-JUN-07:10 | 953.30 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 134.98 | 17-JUN-21:00 | 23.49 | 18-JUN-05:00 |
July | 827.22 | 03-JUL-09:09 | 593.84 | 26-JUL-07:10 | 953.30 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 133.46 | 02-JUL-11:35 | 20.95 | 19-JUL-03:00 |
August | 827.22 | 01-AUG-09:09 | 611.14 | 16-AUG-07:10 | 953.30 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 88.78 | 06-AUG-14:28 | 24.18 | 15-AUG-24:00 |
September | 827.22 | 01-SEP-09:09 | 628.77 | 07-SEP-07:10 | 953.30 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 76.28 | 24-SEP-14:35 | 12.82 | 08-SEP-22:10 |
October | 827.22 | 02-OCT-09:09 | 662.50 | 11-OCT-07:10 | 953.30 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.48 | 15-OCT-12:06 | 42.89 | 12-OCT-03:00 |
November | 827.22 | 01-NOV-09:09 | 671.26 | 27-NOV-16:00 | 953.30 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.41 | 12-NOV-13:52 | 71.81 | 28-NOV-05:00 |
December | 827.22 | 01-DEC-10:09 | 667.63 | 29-DEC-16:00 | 953.30 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 7.98 | 24-DEC-14:27 | 157.24 | 29-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.22 | 456.08 | 953.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.82 | |||||
Maximum of Months | 827.22 | 671.26 | 953.30 | 0.00 | 0.00 | 0.00 | 0.00 | 276.87 | 270.97 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 972.63 | 18-JAN-08:09 | 1505.88 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 19115.49 | 05-JAN-07:01 |
February | 1306.65 | 01-FEB-10:09 | 961.25 | 10-FEB-08:09 | 1505.88 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2890.25 | 22-FEB-13:00 | 16442.20 | 02-FEB-07:02 |
March | 1306.65 | 01-MAR-10:09 | 986.02 | 14-MAR-07:10 | 1505.88 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 12403.44 | 28-MAR-16:02 | 9168.29 | 01-MAR-07:03 |
April | 1306.65 | 03-APR-09:09 | 720.41 | 03-APR-07:10 | 1505.88 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 16945.05 | 27-APR-16:01 | 5086.55 | 10-APR-06:03 |
May | 1306.65 | 01-MAY-09:09 | 841.80 | 24-MAY-07:10 | 1505.88 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 21313.25 | 03-MAY-16:01 | 161.40 | 15-MAY-05:05 |
June | 1306.65 | 01-JUN-09:09 | 848.21 | 23-JUN-07:10 | 1505.88 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 21557.77 | 07-JUN-16:01 | 97.60 | 27-JUN-11:10 |
July | 1306.65 | 03-JUL-09:09 | 975.43 | 26-JUL-07:10 | 1505.88 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 17000.71 | 07-JUL-16:01 | 31.60 | 19-JUL-03:00 |
August | 1306.65 | 01-AUG-09:09 | 994.25 | 16-AUG-07:10 | 1505.88 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 13929.31 | 07-AUG-16:01 | 102.24 | 16-AUG-05:03 |
September | 1306.65 | 01-SEP-09:09 | 1012.91 | 08-SEP-07:10 | 1505.88 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 12349.59 | 26-SEP-16:02 | 457.33 | 27-SEP-06:03 |
October | 1306.65 | 02-OCT-09:09 | 1055.12 | 11-OCT-07:10 | 1505.88 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 11729.76 | 02-OCT-16:02 | 9082.20 | 30-OCT-06:02 |
November | 1306.65 | 01-NOV-09:09 | 972.03 | 27-NOV-16:00 | 1505.88 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4790.75 | 09-NOV-12:03 | 14676.56 | 27-NOV-07:02 |
December | 1306.65 | 01-DEC-10:09 | 1017.00 | 29-DEC-16:00 | 1505.88 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 106.83 | 28-DEC-14:00 | 18922.00 | 21-DEC-07:01 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 720.41 | 1505.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.60 | |||||
Maximum of Months | 1306.65 | 1055.12 | 1505.88 | 0.00 | 0.00 | 0.00 | 0.00 | 21557.77 | 19115.49 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.17 | 02-JAN-10:09 | 640.74 | 18-JAN-08:09 | 953.29 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 99.52 | 15-JAN-17:00 |
February | 827.17 | 01-FEB-10:09 | 631.94 | 10-FEB-08:09 | 953.29 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 13.38 | 19-FEB-14:03 | 132.91 | 09-FEB-22:10 |
March | 827.17 | 01-MAR-10:09 | 648.03 | 14-MAR-07:10 | 953.29 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 86.93 | 26-MAR-13:22 | 281.79 | 24-MAR-24:00 |
April | 827.17 | 03-APR-09:09 | 549.91 | 03-APR-07:10 | 953.29 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 154.92 | 15-APR-17:10 | 40.19 | 22-APR-18:20 |
May | 827.17 | 01-MAY-09:09 | 558.71 | 24-MAY-07:10 | 953.29 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 273.71 | 28-MAY-14:45 | 29.24 | 15-MAY-03:00 |
June | 827.17 | 01-JUN-09:09 | 559.62 | 23-JUN-07:10 | 953.29 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 130.42 | 17-JUN-21:00 | 25.45 | 18-JUN-05:00 |
July | 827.17 | 03-JUL-09:09 | 624.84 | 26-JUL-07:10 | 953.29 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 135.47 | 02-JUL-12:18 | 21.02 | 19-JUL-03:00 |
August | 827.17 | 01-AUG-09:09 | 637.02 | 16-AUG-07:10 | 953.29 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 88.18 | 06-AUG-09:50 | 24.36 | 15-AUG-24:00 |
September | 827.17 | 01-SEP-09:09 | 649.37 | 08-SEP-07:10 | 953.29 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 74.60 | 24-SEP-13:55 | 12.88 | 08-SEP-22:10 |
October | 827.17 | 02-OCT-09:09 | 673.94 | 11-OCT-07:10 | 953.29 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 87.28 | 15-OCT-12:10 | 42.83 | 12-OCT-03:00 |
November | 827.17 | 01-NOV-09:09 | 621.40 | 03-NOV-07:10 | 953.29 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.39 | 12-NOV-13:12 | 71.96 | 28-NOV-05:00 |
December | 827.17 | 01-DEC-10:09 | 633.86 | 29-DEC-16:00 | 953.29 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 7.19 | 24-DEC-13:53 | 157.27 | 29-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.17 | 549.91 | 953.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.88 | |||||
Maximum of Months | 827.17 | 673.94 | 953.29 | 0.00 | 0.00 | 0.00 | 0.00 | 273.71 | 281.79 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 1011.67 | 18-JAN-08:09 | 1505.89 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 6.12 | 08-JAN-15:00 | 220.08 | 15-JAN-17:00 |
February | 1306.65 | 01-FEB-10:09 | 995.20 | 10-FEB-08:09 | 1505.89 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 64.68 | 19-FEB-15:10 | 308.77 | 09-FEB-22:10 |
March | 1306.65 | 01-MAR-10:09 | 1003.24 | 14-MAR-07:10 | 1505.89 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 213.84 | 26-MAR-14:50 | 623.42 | 24-MAR-24:00 |
April | 1306.65 | 03-APR-09:09 | 720.41 | 03-APR-07:10 | 1505.89 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 370.08 | 15-APR-17:02 | 95.97 | 22-APR-18:20 |
May | 1306.65 | 01-MAY-09:09 | 829.70 | 24-MAY-07:10 | 1505.89 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 641.74 | 28-MAY-14:33 | 65.39 | 15-MAY-03:00 |
June | 1306.65 | 01-JUN-09:09 | 823.41 | 23-JUN-07:10 | 1505.89 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 309.55 | 17-JUN-21:00 | 54.29 | 18-JUN-05:00 |
July | 1306.65 | 03-JUL-09:09 | 972.26 | 26-JUL-07:10 | 1505.89 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 313.59 | 02-JUL-11:38 | 45.61 | 19-JUL-03:00 |
August | 1306.65 | 01-AUG-09:09 | 996.57 | 16-AUG-07:10 | 1505.89 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 212.75 | 06-AUG-13:38 | 50.60 | 15-AUG-24:00 |
September | 1306.65 | 01-SEP-09:09 | 1020.91 | 08-SEP-07:10 | 1505.89 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 175.32 | 24-SEP-14:35 | 23.77 | 08-SEP-22:10 |
October | 1306.65 | 02-OCT-09:09 | 1064.19 | 11-OCT-07:10 | 1505.89 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 211.90 | 15-OCT-12:00 | 91.89 | 12-OCT-03:00 |
November | 1306.65 | 01-NOV-09:09 | 1046.41 | 27-NOV-16:00 | 1505.89 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 75.00 | 12-NOV-14:00 | 155.25 | 28-NOV-05:03 |
December | 1306.65 | 01-DEC-10:09 | 1052.37 | 29-DEC-16:00 | 1505.89 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 47.10 | 24-DEC-14:00 | 344.52 | 29-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 720.41 | 1505.89 | 0.00 | 0.00 | 0.00 | 0.00 | 6.12 | 23.77 | |||||
Maximum of Months | 1306.65 | 1064.19 | 1505.89 | 0.00 | 0.00 | 0.00 | 0.00 | 641.74 | 623.42 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 805.43 | 02-JAN-08:09 | 635.93 | 17-JAN-16:00 | 953.30 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 145.45 | 15-JAN-17:00 |
February | 805.43 | 01-FEB-08:09 | 632.36 | 09-FEB-16:00 | 953.30 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 29.52 | 19-FEB-15:10 | 200.99 | 09-FEB-22:10 |
March | 805.43 | 01-MAR-08:09 | 592.13 | 14-MAR-07:10 | 953.30 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 126.98 | 26-MAR-15:10 | 419.79 | 24-MAR-24:00 |
April | 805.43 | 03-APR-07:10 | 456.08 | 03-APR-07:10 | 953.30 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 245.50 | 15-APR-17:02 | 67.65 | 22-APR-18:20 |
May | 805.43 | 01-MAY-07:10 | 456.08 | 01-MAY-07:10 | 953.30 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 431.37 | 28-MAY-14:33 | 44.60 | 15-MAY-03:00 |
June | 805.43 | 01-JUN-07:10 | 456.08 | 01-JUN-07:10 | 953.30 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 211.72 | 17-JUN-21:00 | 35.76 | 18-JUN-05:00 |
July | 805.43 | 03-JUL-07:10 | 598.66 | 26-JUL-07:10 | 953.30 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 208.35 | 02-JUL-11:35 | 30.15 | 19-JUL-03:00 |
August | 805.43 | 01-AUG-07:10 | 615.66 | 16-AUG-07:10 | 953.30 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 144.99 | 06-AUG-13:38 | 33.91 | 15-AUG-24:00 |
September | 805.43 | 01-SEP-07:10 | 632.75 | 07-SEP-07:10 | 953.30 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 118.69 | 24-SEP-14:35 | 15.44 | 08-SEP-22:20 |
October | 805.43 | 02-OCT-07:10 | 665.16 | 11-OCT-07:10 | 953.30 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 125.71 | 15-OCT-13:00 | 60.71 | 12-OCT-03:00 |
November | 805.43 | 01-NOV-07:10 | 673.61 | 27-NOV-16:00 | 953.30 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 42.46 | 12-NOV-14:40 | 103.34 | 28-NOV-05:03 |
December | 805.43 | 01-DEC-08:09 | 670.02 | 29-DEC-16:00 | 953.30 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 20.36 | 24-DEC-13:57 | 227.37 | 29-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 805.43 | 456.08 | 953.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.44 | |||||
Maximum of Months | 805.43 | 673.61 | 953.30 | 0.00 | 0.00 | 0.00 | 0.00 | 431.37 | 419.79 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 981.19 | 18-JAN-08:09 | 1505.88 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 257.23 | 22-JAN-14:03 |
February | 1306.65 | 01-FEB-10:09 | 970.09 | 10-FEB-08:09 | 1505.88 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 13.33 | 21-FEB-15:00 | 309.96 | 09-FEB-22:10 |
March | 1306.65 | 01-MAR-10:09 | 994.03 | 14-MAR-07:10 | 1505.88 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 156.33 | 26-MAR-15:48 | 653.60 | 24-MAR-24:00 |
April | 1306.65 | 03-APR-09:09 | 720.41 | 03-APR-07:10 | 1505.88 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 359.98 | 15-APR-17:10 | 100.61 | 22-APR-18:20 |
May | 1306.65 | 01-MAY-09:09 | 855.60 | 24-MAY-07:10 | 1505.88 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 639.33 | 28-MAY-15:00 | 66.74 | 15-MAY-03:00 |
June | 1306.65 | 01-JUN-09:09 | 861.70 | 23-JUN-07:10 | 1505.88 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 311.56 | 17-JUN-21:00 | 53.85 | 18-JUN-05:00 |
July | 1306.65 | 03-JUL-09:09 | 983.46 | 26-JUL-07:10 | 1505.88 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 312.47 | 02-JUL-11:35 | 45.53 | 19-JUL-03:00 |
August | 1306.65 | 01-AUG-09:09 | 1001.52 | 16-AUG-07:10 | 1505.88 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 203.03 | 06-AUG-14:54 | 50.93 | 15-AUG-24:00 |
September | 1306.65 | 01-SEP-09:09 | 1019.44 | 08-SEP-07:10 | 1505.88 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 166.99 | 24-SEP-15:00 | 23.95 | 08-SEP-22:10 |
October | 1306.65 | 02-OCT-09:09 | 1059.89 | 11-OCT-07:10 | 1505.88 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 175.31 | 15-OCT-13:00 | 92.53 | 12-OCT-03:00 |
November | 1306.65 | 01-NOV-09:09 | 982.33 | 27-NOV-16:00 | 1505.88 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 36.52 | 12-NOV-13:55 | 161.09 | 28-NOV-05:03 |
December | 1306.65 | 01-DEC-10:09 | 1024.11 | 29-DEC-16:00 | 1505.88 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2.97 | 28-DEC-14:00 | 428.87 | 31-DEC-15:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 720.41 | 1505.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.95 | |||||
Maximum of Months | 1306.65 | 1059.89 | 1505.88 | 0.00 | 0.00 | 0.00 | 0.00 | 639.33 | 653.60 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.17 | 02-JAN-10:09 | 643.99 | 18-JAN-08:09 | 953.29 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 146.63 | 15-JAN-17:00 |
February | 827.17 | 01-FEB-10:09 | 635.46 | 10-FEB-08:09 | 953.29 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 18.33 | 19-FEB-14:03 | 200.91 | 09-FEB-22:10 |
March | 827.17 | 01-MAR-10:09 | 651.03 | 14-MAR-07:10 | 953.29 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 126.70 | 26-MAR-13:22 | 434.41 | 24-MAR-24:00 |
April | 827.17 | 03-APR-09:09 | 556.95 | 03-APR-07:10 | 953.29 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 240.49 | 15-APR-17:08 | 65.27 | 22-APR-18:20 |
May | 827.17 | 01-MAY-09:09 | 564.60 | 24-MAY-07:10 | 953.29 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 426.22 | 28-MAY-15:00 | 46.73 | 15-MAY-03:00 |
June | 827.17 | 01-JUN-09:09 | 565.48 | 23-JUN-07:10 | 953.29 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 205.66 | 17-JUN-21:00 | 37.68 | 18-JUN-05:00 |
July | 827.17 | 03-JUL-09:09 | 628.57 | 26-JUL-07:10 | 953.29 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 211.85 | 02-JUL-12:18 | 30.11 | 19-JUL-03:00 |
August | 827.17 | 01-AUG-09:09 | 640.36 | 16-AUG-07:10 | 953.29 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 142.49 | 06-AUG-13:38 | 34.23 | 15-AUG-24:00 |
September | 827.17 | 01-SEP-09:09 | 652.30 | 08-SEP-07:10 | 953.29 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 116.59 | 24-SEP-13:55 | 15.35 | 08-SEP-22:20 |
October | 827.17 | 02-OCT-09:09 | 676.07 | 11-OCT-07:10 | 953.29 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 146.36 | 15-OCT-12:20 | 60.83 | 12-OCT-03:00 |
November | 827.17 | 01-NOV-09:09 | 625.81 | 03-NOV-07:10 | 953.29 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 41.85 | 12-NOV-12:40 | 103.96 | 28-NOV-05:03 |
December | 827.17 | 01-DEC-10:09 | 638.25 | 29-DEC-16:00 | 953.29 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 15.32 | 24-DEC-13:57 | 227.06 | 29-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.17 | 556.95 | 953.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.35 | |||||
Maximum of Months | 827.17 | 676.07 | 953.29 | 0.00 | 0.00 | 0.00 | 0.00 | 426.22 | 434.41 |
Report: PeakSpaceGainsMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 312.31 | 15-JAN-17:00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.65 | 19-FEB-14:53 | 453.98 | 09-FEB-22:10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 247.78 | 26-MAR-14:53 | 912.93 | 24-MAR-24:00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 478.69 | 15-APR-17:02 | 124.65 | 22-APR-18:30 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 806.54 | 28-MAY-15:00 | 72.17 | 15-MAY-04:04 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 381.47 | 03-JUN-17:02 | 67.15 | 18-JUN-05:00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 397.90 | 02-JUL-12:00 | 54.03 | 19-JUL-03:00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 258.98 | 06-AUG-14:00 | 56.05 | 15-AUG-24:00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 214.67 | 24-SEP-14:20 | 29.22 | 19-SEP-04:53 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 241.64 | 15-OCT-13:00 | 119.91 | 12-OCT-03:00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 59.58 | 12-NOV-14:00 | 227.53 | 28-NOV-05:07 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.96 | 24-DEC-14:03 | 496.66 | 29-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.22 | ||
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 806.54 | 912.93 |
Report: PeakSpaceGainsMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 369.30 | 15-JAN-17:00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67.02 | 19-FEB-14:53 | 562.71 | 09-FEB-22:10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 330.25 | 26-MAR-14:53 | 1146.91 | 24-MAR-24:00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 615.18 | 15-APR-17:02 | 156.49 | 22-APR-18:30 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1031.17 | 28-MAY-15:00 | 100.70 | 15-MAY-04:02 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 492.36 | 03-JUN-17:02 | 88.77 | 18-JUN-05:00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 509.85 | 02-JUL-12:00 | 66.74 | 19-JUL-03:00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 331.32 | 06-AUG-14:00 | 70.21 | 15-AUG-24:00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 277.85 | 24-SEP-14:20 | 36.16 | 19-SEP-04:53 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 325.95 | 15-OCT-12:02 | 146.42 | 12-OCT-03:00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89.77 | 12-NOV-13:42 | 269.21 | 28-NOV-05:03 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 50.10 | 24-DEC-14:20 | 604.43 | 29-DEC-24:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.16 | ||
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1031.17 | 1146.91 |
Report: PeakSpaceGainsMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 366.11 | 15-JAN-17:00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.06 | 24-FEB-16:00 | 535.41 | 09-FEB-22:05 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 177.34 | 26-MAR-15:00 | 938.22 | 24-MAR-24:00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 587.32 | 15-APR-17:02 | 116.80 | 22-APR-19:00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 961.53 | 28-MAY-15:00 | 84.17 | 15-MAY-04:04 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 518.05 | 17-JUN-20:50 | 81.29 | 18-JUN-05:00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 450.56 | 02-JUL-11:32 | 60.72 | 19-JUL-03:00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 298.81 | 06-AUG-09:03 | 82.18 | 15-AUG-24:00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 227.08 | 24-SEP-14:30 | 25.49 | 19-SEP-04:53 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 253.09 | 15-OCT-11:42 | 138.40 | 12-OCT-03:00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 37.17 | 12-NOV-13:50 | 225.61 | 28-NOV-05:03 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 609.89 | 31-DEC-15:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.49 | ||
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 961.53 | 938.22 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 39757.12 | 27-JAN-06:03 | 2541.06 | 2463.50 | 20553.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 41850.32 | 15-FEB-06:03 | 2541.06 | 2463.50 | 20553.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 45373.12 | 13-MAR-04:02 | 0.00 | 3079.37 | 25692.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 45576.39 | 10-APR-04:02 | 0.00 | 3079.37 | 25692.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 43986.18 | 25-MAY-04:03 | 0.00 | 2463.50 | 20553.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 43666.51 | 28-JUN-04:03 | 0.00 | 2463.50 | 20553.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 43607.28 | 19-JUL-04:03 | 0.00 | 2463.50 | 20553.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 43018.99 | 24-AUG-04:03 | 0.00 | 2463.50 | 20553.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 43153.47 | 07-SEP-04:03 | 0.00 | 2463.50 | 20553.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 44118.70 | 17-OCT-04:03 | 0.00 | 2463.50 | 20553.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 45116.87 | 13-NOV-05:02 | 0.00 | 3079.37 | 25692.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 42023.40 | 11-DEC-06:02 | 3176.32 | 3079.37 | 25692.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 39757.12 | 0.00 | 2463.50 | 20553.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 45576.39 | 3176.32 | 3079.37 | 25692.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 4281.86 | 12-JAN-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.52 |
February | 8117.97 | 22-FEB-14:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.92 | 0.00 |
March | 12331.32 | 28-MAR-15:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 14566.74 | 26-APR-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 54.96 | 0.00 |
May | 16305.12 | 01-MAY-14:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 155.23 | 0.00 |
June | 16588.61 | 12-JUN-12:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 198.59 | 0.00 |
July | 15040.54 | 10-JUL-13:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.77 | 0.00 |
August | 13608.43 | 07-AUG-14:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 111.57 | 0.00 |
September | 12283.99 | 26-SEP-14:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49.54 | 0.00 |
October | 12379.28 | 02-OCT-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58.95 | 0.00 |
November | 8619.79 | 09-NOV-14:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.41 | 0.00 |
December | 5470.88 | 01-DEC-14:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.49 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 4281.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 16588.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 198.59 | 24.52 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1859.61 | 04-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 2712.18 | 22-FEB-15:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.07 | 0.00 |
March | 4904.22 | 13-MAR-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.57 | 0.00 |
April | 5963.70 | 17-APR-15:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 154.98 | 0.00 |
May | 6712.80 | 30-MAY-11:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 112.60 | 0.00 |
June | 8701.63 | 12-JUN-06:15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 79.37 | 0.00 |
July | 6660.65 | 05-JUL-12:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 96.79 | 0.00 |
August | 6891.09 | 14-AUG-06:15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.15 | 0.00 |
September | 6663.31 | 05-SEP-06:15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.98 | 0.00 |
October | 5604.12 | 02-OCT-15:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38.02 | 0.00 |
November | 3589.56 | 13-NOV-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.95 | 0.00 |
December | 1713.44 | 01-DEC-15:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 1713.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 8701.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 154.98 | 5.10 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2283.22 | 05-JAN-07:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 3583.95 | 21-FEB-16:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.93 | 0.00 |
March | 5092.12 | 28-MAR-17:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 7036.11 | 28-APR-12:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 119.18 | 0.00 |
May | 8686.80 | 30-MAY-12:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 88.08 | 0.00 |
June | 7889.84 | 12-JUN-07:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89.04 | 0.00 |
July | 7970.82 | 05-JUL-07:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.86 | 0.00 |
August | 6746.32 | 07-AUG-17:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 65.25 | 0.00 |
September | 6811.96 | 05-SEP-06:15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.57 | 0.00 |
October | 5653.71 | 16-OCT-17:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.83 | 0.00 |
November | 4443.36 | 13-NOV-16:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.07 | 0.00 |
December | 2819.56 | 01-DEC-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.03 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 2283.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 8686.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 119.18 | 6.03 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 12561.00 | 26-JAN-17:00 | 6035.01 | 5543.17 | 7143.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 28386.13 | 21-FEB-06:03 | 2541.06 | 2463.50 | 12699.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 34238.90 | 13-MAR-04:02 | 0.00 | 3079.37 | 15874.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 34529.55 | 10-APR-04:02 | 0.00 | 3079.37 | 15874.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 32410.03 | 25-MAY-04:03 | 0.00 | 2463.50 | 12699.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 32099.02 | 21-JUN-04:03 | 0.00 | 2463.50 | 12699.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 32129.86 | 13-JUL-04:03 | 0.00 | 2463.50 | 12699.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 32665.93 | 16-AUG-04:03 | 0.00 | 2463.50 | 12699.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 33242.69 | 27-SEP-04:02 | 0.00 | 3079.37 | 15874.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 34422.47 | 10-OCT-04:02 | 0.00 | 3079.37 | 15874.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 33274.01 | 13-NOV-05:02 | 0.00 | 3079.37 | 15874.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 13782.06 | 01-DEC-17:00 | 6035.01 | 5543.17 | 7143.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 12561.00 | 0.00 | 2463.50 | 7143.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 34529.55 | 6035.01 | 5543.17 | 15874.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 12043.95 | 26-JAN-16:20 | 6035.01 | 5543.17 | 7143.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 15828.16 | 23-FEB-15:00 | 6198.29 | 5543.17 | 7143.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 34366.25 | 13-MAR-04:02 | 0.00 | 3079.37 | 15874.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 37696.20 | 18-APR-04:02 | 0.00 | 3079.37 | 15874.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 37932.11 | 15-MAY-04:02 | 0.00 | 3079.37 | 15874.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 36870.31 | 19-JUN-04:02 | 0.00 | 3079.37 | 15874.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 36088.13 | 11-JUL-04:02 | 0.00 | 3079.37 | 15874.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 36932.90 | 15-AUG-04:02 | 0.00 | 3079.37 | 15874.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 37398.64 | 06-SEP-04:02 | 0.00 | 3079.37 | 15874.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 38494.52 | 10-OCT-04:02 | 0.00 | 3079.37 | 15874.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 17219.20 | 13-NOV-15:00 | 6198.29 | 5543.17 | 7143.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 13229.83 | 01-DEC-16:20 | 6035.01 | 5543.17 | 7143.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 12043.95 | 0.00 | 3079.37 | 7143.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 38494.52 | 6198.29 | 5543.17 | 15874.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2713.50 | 26-JAN-14:50 | 1306.65 | 720.41 | 1505.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.77 |
February | 4437.14 | 23-FEB-14:40 | 1306.65 | 720.41 | 1505.89 | 0.00 | 0.00 | 0.00 | 0.00 | 7.04 | 0.00 |
March | 6544.63 | 13-MAR-15:20 | 1272.23 | 720.41 | 1505.89 | 0.00 | 0.00 | 0.00 | 0.00 | 21.93 | 0.00 |
April | 15084.48 | 16-APR-15:22 | 401.76 | 240.15 | 3011.78 | 0.00 | 0.00 | 0.00 | 0.00 | 68.43 | 0.00 |
May | 15549.05 | 28-MAY-16:31 | 468.72 | 280.18 | 3513.75 | 0.00 | 0.00 | 0.00 | 0.00 | 651.80 | 0.00 |
June | 15626.86 | 04-JUN-16:21 | 535.68 | 320.20 | 4015.71 | 0.00 | 0.00 | 0.00 | 0.00 | 278.72 | 0.00 |
July | 15224.36 | 04-JUL-17:12 | 0.00 | 240.15 | 3011.78 | 0.00 | 0.00 | 0.00 | 0.00 | 161.05 | 0.00 |
August | 15173.79 | 06-AUG-14:42 | 401.76 | 240.15 | 3011.78 | 0.00 | 0.00 | 0.00 | 0.00 | 214.60 | 0.00 |
September | 12782.60 | 25-SEP-04:02 | 0.00 | 649.16 | 3346.43 | 0.00 | 0.00 | 0.00 | 0.00 | 4.27 | 0.00 |
October | 9463.97 | 01-OCT-15:02 | 334.80 | 200.13 | 2509.82 | 0.00 | 0.00 | 0.00 | 0.00 | 97.23 | 0.00 |
November | 4811.94 | 09-NOV-14:30 | 1306.65 | 720.41 | 1505.89 | 0.00 | 0.00 | 0.00 | 0.00 | 9.74 | 0.00 |
December | 2691.59 | 01-DEC-15:00 | 1306.65 | 720.41 | 1505.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.45 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 2691.59 | 0.00 | 200.13 | 1505.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 15626.86 | 1306.65 | 720.41 | 4015.71 | 0.00 | 0.00 | 0.00 | 0.00 | 651.80 | 14.77 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2226.55 | 26-JAN-14:10 | 827.22 | 456.08 | 953.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.94 |
February | 4107.01 | 22-FEB-10:50 | 827.22 | 456.08 | 953.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.96 |
March | 9385.74 | 12-MAR-09:53 | 169.56 | 101.36 | 1271.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.71 |
April | 12029.30 | 16-APR-10:02 | 211.95 | 126.70 | 1588.83 | 0.00 | 0.00 | 0.00 | 0.00 | 24.72 | 0.00 |
May | 12349.46 | 29-MAY-09:22 | 254.35 | 152.04 | 1906.59 | 0.00 | 0.00 | 0.00 | 0.00 | 347.61 | 0.00 |
June | 11901.05 | 11-JUN-10:22 | 211.95 | 126.70 | 1588.83 | 0.00 | 0.00 | 0.00 | 0.00 | 79.39 | 0.00 |
July | 12043.16 | 04-JUL-08:32 | 211.95 | 126.70 | 1588.83 | 0.00 | 0.00 | 0.00 | 0.00 | 47.27 | 0.00 |
August | 12121.93 | 06-AUG-10:02 | 211.95 | 126.70 | 1588.83 | 0.00 | 0.00 | 0.00 | 0.00 | 118.77 | 0.00 |
September | 8581.09 | 25-SEP-04:02 | 0.00 | 410.97 | 2118.43 | 0.00 | 0.00 | 0.00 | 0.00 | 3.15 | 0.00 |
October | 11650.70 | 09-OCT-11:02 | 211.95 | 126.70 | 1588.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.61 | 0.00 |
November | 4164.82 | 09-NOV-10:30 | 827.22 | 456.08 | 953.30 | 0.00 | 0.00 | 0.00 | 0.00 | 1.26 | 0.00 |
December | 2497.74 | 01-DEC-10:50 | 827.22 | 456.08 | 953.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.27 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 2226.55 | 0.00 | 101.36 | 953.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 12349.46 | 827.22 | 456.08 | 2118.43 | 0.00 | 0.00 | 0.00 | 0.00 | 347.61 | 7.94 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 8284.51 | 12-JAN-14:10 | 1306.65 | 720.41 | 1505.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.08 |
February | 16497.20 | 20-FEB-14:22 | 334.80 | 200.13 | 2509.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.85 |
March | 15875.83 | 12-MAR-11:53 | 267.84 | 160.10 | 2007.84 | 0.00 | 0.00 | 0.00 | 0.00 | 19.56 | 0.00 |
April | 15866.14 | 16-APR-13:22 | 334.80 | 200.13 | 2509.80 | 0.00 | 0.00 | 0.00 | 0.00 | 100.48 | 0.00 |
May | 15906.52 | 28-MAY-15:11 | 468.72 | 280.18 | 3513.73 | 0.00 | 0.00 | 0.00 | 0.00 | 719.49 | 0.00 |
June | 15828.81 | 04-JUN-15:41 | 535.68 | 320.20 | 4015.69 | 0.00 | 0.00 | 0.00 | 0.00 | 298.51 | 0.00 |
July | 15454.44 | 30-JUL-12:53 | 267.84 | 160.10 | 2007.84 | 0.00 | 0.00 | 0.00 | 0.00 | 157.02 | 0.00 |
August | 15891.65 | 06-AUG-14:42 | 401.76 | 240.15 | 3011.77 | 0.00 | 0.00 | 0.00 | 0.00 | 204.10 | 0.00 |
September | 15790.41 | 24-SEP-14:02 | 334.80 | 200.13 | 2509.80 | 0.00 | 0.00 | 0.00 | 0.00 | 189.21 | 0.00 |
October | 17386.40 | 09-OCT-12:22 | 401.76 | 240.15 | 3011.77 | 0.00 | 0.00 | 0.00 | 0.00 | 9.89 | 0.00 |
November | 16468.20 | 23-NOV-13:22 | 334.80 | 200.13 | 2509.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.72 |
December | 15581.89 | 03-DEC-13:32 | 267.84 | 160.10 | 2007.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.59 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 8284.51 | 267.84 | 160.10 | 1505.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 17386.40 | 1306.65 | 720.41 | 4015.69 | 0.00 | 0.00 | 0.00 | 0.00 | 719.49 | 11.72 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3548.67 | 31-JAN-16:10 | 805.38 | 456.05 | 953.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.07 |
February | 8183.43 | 20-FEB-15:43 | 169.55 | 101.35 | 1271.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.11 |
March | 13313.54 | 26-MAR-16:12 | 211.94 | 126.69 | 1588.81 | 0.00 | 0.00 | 0.00 | 0.00 | 73.75 | 0.00 |
April | 13609.92 | 30-APR-16:22 | 254.33 | 152.03 | 1906.58 | 0.00 | 0.00 | 0.00 | 0.00 | 206.26 | 0.00 |
May | 14215.68 | 28-MAY-16:31 | 296.72 | 177.36 | 2224.34 | 0.00 | 0.00 | 0.00 | 0.00 | 397.53 | 0.00 |
June | 14159.55 | 04-JUN-16:21 | 339.11 | 202.70 | 2542.10 | 0.00 | 0.00 | 0.00 | 0.00 | 171.89 | 0.00 |
July | 13384.74 | 04-JUL-16:32 | 254.33 | 152.03 | 1906.58 | 0.00 | 0.00 | 0.00 | 0.00 | 100.66 | 0.00 |
August | 13420.65 | 06-AUG-14:42 | 254.33 | 152.03 | 1906.58 | 0.00 | 0.00 | 0.00 | 0.00 | 131.32 | 0.00 |
September | 12948.92 | 24-SEP-15:22 | 211.94 | 126.69 | 1588.81 | 0.00 | 0.00 | 0.00 | 0.00 | 114.10 | 0.00 |
October | 13053.73 | 01-OCT-15:42 | 211.94 | 126.69 | 1588.81 | 0.00 | 0.00 | 0.00 | 0.00 | 49.94 | 0.00 |
November | 5742.15 | 08-NOV-15:30 | 805.38 | 456.05 | 953.29 | 0.00 | 0.00 | 0.00 | 0.00 | 5.21 | 0.00 |
December | 3899.74 | 01-DEC-15:30 | 805.38 | 456.05 | 953.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.79 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 3548.67 | 169.55 | 101.35 | 953.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 14215.68 | 805.38 | 456.05 | 2542.10 | 0.00 | 0.00 | 0.00 | 0.00 | 397.53 | 11.07 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2496.83 | 26-JAN-14:10 | 1306.65 | 720.41 | 1505.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.14 |
February | 3554.56 | 24-FEB-15:00 | 1306.65 | 720.41 | 1505.89 | 0.00 | 0.00 | 0.00 | 0.00 | 7.32 | 0.00 |
March | 4941.83 | 13-MAR-15:20 | 1272.23 | 720.41 | 1505.89 | 0.00 | 0.00 | 0.00 | 0.00 | 11.73 | 0.00 |
April | 7403.63 | 28-APR-04:02 | 0.00 | 649.16 | 3346.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 12284.97 | 07-MAY-16:31 | 669.60 | 400.26 | 5019.64 | 0.00 | 0.00 | 0.00 | 0.00 | 147.61 | 0.00 |
June | 12440.11 | 11-JUN-16:11 | 669.60 | 400.26 | 5019.64 | 0.00 | 0.00 | 0.00 | 0.00 | 75.54 | 0.00 |
July | 12247.39 | 09-JUL-17:32 | 0.00 | 200.13 | 2509.82 | 0.00 | 0.00 | 0.00 | 0.00 | 92.84 | 0.00 |
August | 10783.09 | 14-AUG-04:03 | 0.00 | 519.33 | 2677.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 12170.69 | 24-SEP-16:32 | 401.76 | 240.15 | 3011.78 | 0.00 | 0.00 | 0.00 | 0.00 | 67.27 | 0.00 |
October | 10198.13 | 01-OCT-14:42 | 401.76 | 240.15 | 3011.78 | 0.00 | 0.00 | 0.00 | 0.00 | 56.07 | 0.00 |
November | 4541.58 | 09-NOV-14:10 | 1306.65 | 720.41 | 1505.89 | 0.00 | 0.00 | 0.00 | 0.00 | 5.51 | 0.00 |
December | 2911.99 | 01-DEC-15:00 | 1306.65 | 720.41 | 1505.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.71 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 2496.83 | 0.00 | 200.13 | 1505.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 12440.11 | 1306.65 | 720.41 | 5019.64 | 0.00 | 0.00 | 0.00 | 0.00 | 147.61 | 6.14 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2437.40 | 26-JAN-11:00 | 827.22 | 456.08 | 953.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.33 |
February | 3775.97 | 22-FEB-10:40 | 827.22 | 456.08 | 953.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.52 |
March | 5289.03 | 28-MAR-10:30 | 805.43 | 456.08 | 953.30 | 0.00 | 0.00 | 0.00 | 0.00 | 4.71 | 0.00 |
April | 9617.09 | 30-APR-09:42 | 211.95 | 126.70 | 1588.83 | 0.00 | 0.00 | 0.00 | 0.00 | 23.73 | 0.00 |
May | 10444.94 | 07-MAY-09:51 | 339.13 | 202.72 | 2542.12 | 0.00 | 0.00 | 0.00 | 0.00 | 81.52 | 0.00 |
June | 10633.09 | 11-JUN-09:32 | 254.35 | 152.04 | 1906.59 | 0.00 | 0.00 | 0.00 | 0.00 | 29.95 | 0.00 |
July | 10203.63 | 16-JUL-10:32 | 211.95 | 126.70 | 1588.83 | 0.00 | 0.00 | 0.00 | 0.00 | 34.57 | 0.00 |
August | 10203.93 | 06-AUG-10:23 | 169.56 | 101.36 | 1271.06 | 0.00 | 0.00 | 0.00 | 0.00 | 69.15 | 0.00 |
September | 9860.03 | 24-SEP-16:32 | 254.35 | 152.04 | 1906.59 | 0.00 | 0.00 | 0.00 | 0.00 | 44.41 | 0.00 |
October | 10141.79 | 09-OCT-11:02 | 211.95 | 126.70 | 1588.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.32 | 0.00 |
November | 4438.54 | 13-NOV-10:30 | 827.22 | 456.08 | 953.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 |
December | 3066.32 | 01-DEC-10:30 | 827.22 | 456.08 | 953.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.81 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 2437.40 | 169.56 | 101.36 | 953.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 10633.09 | 827.22 | 456.08 | 2542.12 | 0.00 | 0.00 | 0.00 | 0.00 | 81.52 | 10.33 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 7337.87 | 12-JAN-14:10 | 1306.65 | 720.41 | 1505.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 117.00 |
February | 13234.70 | 20-FEB-14:22 | 334.80 | 200.13 | 2509.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.98 |
March | 12407.29 | 28-MAR-16:10 | 2410.55 | 2401.36 | 5019.61 | 0.00 | 0.00 | 0.00 | 0.00 | 10296.36 | 0.00 |
April | 13646.27 | 27-APR-16:50 | 401.76 | 400.23 | 836.60 | 0.00 | 0.00 | 0.00 | 0.00 | 12996.24 | 0.00 |
May | 14884.45 | 01-MAY-16:50 | 401.76 | 400.23 | 836.60 | 0.00 | 0.00 | 0.00 | 0.00 | 15585.43 | 0.00 |
June | 15207.83 | 12-JUN-17:00 | 401.76 | 400.23 | 836.60 | 0.00 | 0.00 | 0.00 | 0.00 | 15975.32 | 0.00 |
July | 13944.68 | 03-JUL-17:00 | 401.76 | 400.23 | 836.60 | 0.00 | 0.00 | 0.00 | 0.00 | 12967.32 | 0.00 |
August | 13102.43 | 07-AUG-16:50 | 401.76 | 400.23 | 836.60 | 0.00 | 0.00 | 0.00 | 0.00 | 11029.42 | 0.00 |
September | 13190.04 | 29-SEP-12:00 | 687.71 | 720.41 | 1338.56 | 0.00 | 0.00 | 0.00 | 0.00 | 9436.15 | 0.00 |
October | 14092.94 | 01-OCT-12:42 | 401.76 | 240.15 | 3011.77 | 0.00 | 0.00 | 0.00 | 0.00 | 43.52 | 0.00 |
November | 13974.32 | 12-NOV-13:42 | 401.76 | 240.15 | 3011.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.00 |
December | 10896.75 | 03-DEC-11:43 | 200.88 | 120.08 | 1505.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.76 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 7337.87 | 200.88 | 120.08 | 836.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 15207.83 | 2410.55 | 2401.36 | 5019.61 | 0.00 | 0.00 | 0.00 | 0.00 | 15975.32 | 117.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3091.93 | 31-JAN-16:30 | 805.38 | 456.05 | 953.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.18 |
February | 4336.86 | 21-FEB-16:10 | 805.38 | 456.05 | 953.29 | 0.00 | 0.00 | 0.00 | 0.00 | 5.30 | 0.00 |
March | 8553.11 | 26-MAR-17:03 | 0.00 | 101.35 | 1271.05 | 0.00 | 0.00 | 0.00 | 0.00 | 37.36 | 0.00 |
April | 10694.05 | 30-APR-16:22 | 254.33 | 152.03 | 1906.58 | 0.00 | 0.00 | 0.00 | 0.00 | 117.87 | 0.00 |
May | 11078.71 | 07-MAY-16:31 | 423.88 | 253.38 | 3177.63 | 0.00 | 0.00 | 0.00 | 0.00 | 91.44 | 0.00 |
June | 11147.00 | 11-JUN-16:11 | 423.88 | 253.38 | 3177.63 | 0.00 | 0.00 | 0.00 | 0.00 | 47.38 | 0.00 |
July | 10727.87 | 02-JUL-16:12 | 211.94 | 126.69 | 1588.81 | 0.00 | 0.00 | 0.00 | 0.00 | 80.30 | 0.00 |
August | 9708.01 | 27-AUG-15:32 | 254.33 | 152.03 | 1906.58 | 0.00 | 0.00 | 0.00 | 0.00 | 33.78 | 0.00 |
September | 11049.05 | 24-SEP-16:32 | 254.33 | 152.03 | 1906.58 | 0.00 | 0.00 | 0.00 | 0.00 | 38.10 | 0.00 |
October | 11223.75 | 01-OCT-16:02 | 254.33 | 152.03 | 1906.58 | 0.00 | 0.00 | 0.00 | 0.00 | 20.53 | 0.00 |
November | 9470.70 | 05-NOV-15:22 | 211.94 | 126.69 | 1588.81 | 0.00 | 0.00 | 0.00 | 0.00 | 1.84 | 0.00 |
December | 3678.44 | 01-DEC-15:40 | 805.38 | 456.05 | 953.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.06 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 3091.93 | 0.00 | 101.35 | 953.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 11223.75 | 805.38 | 456.05 | 3177.63 | 0.00 | 0.00 | 0.00 | 0.00 | 117.87 | 6.18 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2806.87 | 26-JAN-14:30 | 1306.65 | 720.41 | 1505.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.04 |
February | 4174.08 | 23-FEB-14:30 | 1306.65 | 720.41 | 1505.89 | 0.00 | 0.00 | 0.00 | 0.00 | 6.11 | 0.00 |
March | 5845.09 | 13-MAR-15:20 | 1272.23 | 720.41 | 1505.89 | 0.00 | 0.00 | 0.00 | 0.00 | 18.31 | 0.00 |
April | 12412.98 | 30-APR-16:11 | 602.64 | 360.23 | 4517.68 | 0.00 | 0.00 | 0.00 | 0.00 | 290.47 | 0.00 |
May | 12741.08 | 28-MAY-16:31 | 468.72 | 280.18 | 3513.75 | 0.00 | 0.00 | 0.00 | 0.00 | 553.23 | 0.00 |
June | 12953.27 | 04-JUN-14:32 | 401.76 | 240.15 | 3011.78 | 0.00 | 0.00 | 0.00 | 0.00 | 259.92 | 0.00 |
July | 12552.93 | 04-JUL-17:12 | 0.00 | 240.15 | 3011.78 | 0.00 | 0.00 | 0.00 | 0.00 | 136.32 | 0.00 |
August | 12413.89 | 06-AUG-15:32 | 401.76 | 240.15 | 3011.78 | 0.00 | 0.00 | 0.00 | 0.00 | 172.46 | 0.00 |
September | 12422.32 | 24-SEP-16:32 | 401.76 | 240.15 | 3011.78 | 0.00 | 0.00 | 0.00 | 0.00 | 104.91 | 0.00 |
October | 8357.81 | 02-OCT-04:02 | 0.00 | 649.16 | 3346.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 4440.97 | 09-NOV-14:10 | 1306.65 | 720.41 | 1505.89 | 0.00 | 0.00 | 0.00 | 0.00 | 8.58 | 0.00 |
December | 2815.66 | 01-DEC-15:00 | 1306.65 | 720.41 | 1505.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.16 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 2806.87 | 0.00 | 240.15 | 1505.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 12953.27 | 1306.65 | 720.41 | 4517.68 | 0.00 | 0.00 | 0.00 | 0.00 | 553.23 | 11.04 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2540.28 | 26-JAN-11:10 | 805.43 | 456.08 | 953.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.61 |
February | 4308.39 | 22-FEB-10:00 | 805.43 | 456.08 | 953.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.57 |
March | 10157.18 | 12-MAR-10:23 | 169.56 | 101.36 | 1271.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.95 | 0.00 |
April | 11495.85 | 30-APR-08:52 | 254.35 | 152.04 | 1906.59 | 0.00 | 0.00 | 0.00 | 0.00 | 1.71 | 0.00 |
May | 11173.52 | 29-MAY-09:22 | 254.35 | 152.04 | 1906.59 | 0.00 | 0.00 | 0.00 | 0.00 | 294.85 | 0.00 |
June | 11352.53 | 11-JUN-09:32 | 254.35 | 152.04 | 1906.59 | 0.00 | 0.00 | 0.00 | 0.00 | 44.58 | 0.00 |
July | 10952.12 | 04-JUL-08:32 | 211.95 | 126.70 | 1588.83 | 0.00 | 0.00 | 0.00 | 0.00 | 39.46 | 0.00 |
August | 10753.48 | 06-AUG-09:32 | 169.56 | 101.36 | 1271.06 | 0.00 | 0.00 | 0.00 | 0.00 | 107.05 | 0.00 |
September | 10111.88 | 24-SEP-16:32 | 254.35 | 152.04 | 1906.59 | 0.00 | 0.00 | 0.00 | 0.00 | 70.66 | 0.00 |
October | 10958.93 | 01-OCT-10:12 | 211.95 | 126.70 | 1588.83 | 0.00 | 0.00 | 0.00 | 0.00 | 15.90 | 0.00 |
November | 4297.90 | 13-NOV-10:00 | 805.43 | 456.08 | 953.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.68 |
December | 3038.09 | 01-DEC-10:00 | 805.43 | 456.08 | 953.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.21 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 2540.28 | 169.56 | 101.36 | 953.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 11495.85 | 805.43 | 456.08 | 1906.59 | 0.00 | 0.00 | 0.00 | 0.00 | 294.85 | 15.61 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 8127.95 | 12-JAN-13:50 | 1272.23 | 720.41 | 1505.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.52 |
February | 13519.66 | 20-FEB-15:13 | 267.84 | 160.10 | 2007.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.87 |
March | 13901.55 | 12-MAR-13:02 | 334.80 | 200.13 | 2509.80 | 0.00 | 0.00 | 0.00 | 0.00 | 16.85 | 0.00 |
April | 13231.90 | 02-APR-12:43 | 267.84 | 160.10 | 2007.84 | 0.00 | 0.00 | 0.00 | 0.00 | 150.24 | 0.00 |
May | 13051.26 | 28-MAY-15:11 | 468.72 | 280.18 | 3513.73 | 0.00 | 0.00 | 0.00 | 0.00 | 611.90 | 0.00 |
June | 13292.49 | 04-JUN-14:32 | 401.76 | 240.15 | 3011.77 | 0.00 | 0.00 | 0.00 | 0.00 | 258.53 | 0.00 |
July | 12777.19 | 04-JUL-15:52 | 401.76 | 240.15 | 3011.77 | 0.00 | 0.00 | 0.00 | 0.00 | 133.70 | 0.00 |
August | 13100.79 | 06-AUG-12:53 | 267.84 | 160.10 | 2007.84 | 0.00 | 0.00 | 0.00 | 0.00 | 179.21 | 0.00 |
September | 13336.39 | 24-SEP-12:32 | 401.76 | 240.15 | 3011.77 | 0.00 | 0.00 | 0.00 | 0.00 | 110.03 | 0.00 |
October | 14459.19 | 01-OCT-11:32 | 401.76 | 240.15 | 3011.77 | 0.00 | 0.00 | 0.00 | 0.00 | 49.98 | 0.00 |
November | 14514.63 | 12-NOV-13:12 | 401.76 | 240.15 | 3011.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.65 |
December | 13398.05 | 03-DEC-13:23 | 267.84 | 160.10 | 2007.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.77 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 8127.95 | 267.84 | 160.10 | 1505.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 14514.63 | 1272.23 | 720.41 | 3513.73 | 0.00 | 0.00 | 0.00 | 0.00 | 611.90 | 10.65 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3570.74 | 31-JAN-16:10 | 805.38 | 456.05 | 953.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.14 |
February | 6663.32 | 20-FEB-16:33 | 127.16 | 76.01 | 953.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.12 |
March | 11146.21 | 26-MAR-15:43 | 169.55 | 101.35 | 1271.05 | 0.00 | 0.00 | 0.00 | 0.00 | 84.10 | 0.00 |
April | 11814.35 | 30-APR-16:11 | 381.49 | 228.04 | 2859.87 | 0.00 | 0.00 | 0.00 | 0.00 | 169.68 | 0.00 |
May | 12007.63 | 28-MAY-16:31 | 296.72 | 177.36 | 2224.34 | 0.00 | 0.00 | 0.00 | 0.00 | 338.76 | 0.00 |
June | 12086.39 | 11-JUN-16:11 | 423.88 | 253.38 | 3177.63 | 0.00 | 0.00 | 0.00 | 0.00 | 72.64 | 0.00 |
July | 11469.14 | 02-JUL-16:12 | 211.94 | 126.69 | 1588.81 | 0.00 | 0.00 | 0.00 | 0.00 | 123.71 | 0.00 |
August | 11657.40 | 06-AUG-16:12 | 254.33 | 152.03 | 1906.58 | 0.00 | 0.00 | 0.00 | 0.00 | 91.90 | 0.00 |
September | 11701.57 | 24-SEP-16:32 | 254.33 | 152.03 | 1906.58 | 0.00 | 0.00 | 0.00 | 0.00 | 59.09 | 0.00 |
October | 11493.02 | 01-OCT-15:31 | 296.72 | 177.36 | 2224.34 | 0.00 | 0.00 | 0.00 | 0.00 | 42.64 | 0.00 |
November | 10151.27 | 05-NOV-15:22 | 211.94 | 126.69 | 1588.81 | 0.00 | 0.00 | 0.00 | 0.00 | 2.81 | 0.00 |
December | 3893.88 | 01-DEC-15:30 | 805.38 | 456.05 | 953.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.46 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 3570.74 | 127.16 | 76.01 | 953.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 12086.39 | 805.38 | 456.05 | 3177.63 | 0.00 | 0.00 | 0.00 | 0.00 | 338.76 | 11.12 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | NATURALGAS:FACILITY [J] | NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | |
January | 0.116615E+12 | 101465.29 | 02-JAN-07:10 | 0.955278E+10 | 20932.15 | 03-JAN-06:10 |
February | 0.113139E+12 | 115678.09 | 22-FEB-16:10 | 0.765782E+10 | 14684.39 | 02-FEB-06:40 |
March | 0.149832E+12 | 149370.45 | 28-MAR-15:00 | 0.832484E+10 | 8879.60 | 01-MAR-12:20 |
April | 0.170989E+12 | 171867.72 | 26-APR-15:20 | 0.735235E+10 | 8740.38 | 03-APR-11:20 |
May | 0.214023E+12 | 197436.78 | 01-MAY-15:09 | 0.729913E+10 | 8619.31 | 01-MAY-11:09 |
June | 0.220645E+12 | 200684.14 | 12-JUN-14:09 | 0.680567E+10 | 8483.73 | 02-JUN-11:20 |
July | 0.213584E+12 | 195124.53 | 10-JUL-12:00 | 0.663279E+10 | 8414.57 | 05-JUL-11:20 |
August | 0.215785E+12 | 190641.61 | 07-AUG-15:20 | 0.701965E+10 | 8469.20 | 30-AUG-11:20 |
September | 0.184906E+12 | 172523.22 | 14-SEP-15:20 | 0.687755E+10 | 8584.92 | 29-SEP-11:20 |
October | 0.161810E+12 | 161551.39 | 02-OCT-15:09 | 0.752274E+10 | 8729.27 | 31-OCT-11:20 |
November | 0.133821E+12 | 123833.12 | 06-NOV-13:00 | 0.775790E+10 | 8857.07 | 30-NOV-12:50 |
December | 0.117507E+12 | 102761.87 | 01-DEC-15:30 | 0.845097E+10 | 18566.01 | 21-DEC-06:40 |
Annual Sum or Average | 0.201266E+13 | 0.912542E+11 | ||||
Minimum of Months | 0.113139E+12 | 101465.29 | 0.663279E+10 | 8414.57 | ||
Maximum of Months | 0.220645E+12 | 200684.14 | 0.955278E+10 | 20932.15 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [J] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [J] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 0.236273E+11 | 0.708066E+10 | 0.641572E+11 | 0.109096E+10 | 0.503658E+10 | 1312252.65 | 0.211377E+10 | 0.135071E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.213320E+11 | 0.607759E+10 | 0.580684E+11 | 0.987279E+09 | 0.614094E+10 | 1186778.30 | 0.608096E+09 | 0.199236E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.251605E+11 | 0.621370E+10 | 0.666107E+11 | 0.114317E+10 | 0.108718E+11 | 1343621.24 | 89104039.23 | 0.397414E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.224124E+11 | 0.550922E+10 | 0.619407E+11 | 0.105059E+10 | 0.153164E+11 | 1267813.82 | 0.00 | 0.647585E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.241010E+11 | 0.525004E+10 | 0.653840E+11 | 0.111689E+10 | 0.196096E+11 | 1327936.95 | 0.00 | 0.985604E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.239766E+11 | 0.484233E+10 | 0.641577E+11 | 0.109962E+10 | 0.197146E+11 | 1296568.36 | 0.00 | 0.106853E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.225286E+11 | 0.513334E+10 | 0.631525E+11 | 0.106768E+10 | 0.177947E+11 | 1299182.41 | 0.00 | 0.103906E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.251177E+11 | 0.549013E+10 | 0.666107E+11 | 0.114316E+10 | 0.180376E+11 | 1343621.24 | 0.00 | 0.993847E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.225163E+11 | 0.579598E+10 | 0.619118E+11 | 0.105026E+10 | 0.149717E+11 | 1267813.82 | 0.00 | 0.786587E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.234800E+11 | 0.651380E+10 | 0.641717E+11 | 0.109108E+10 | 0.123058E+11 | 1312252.65 | 0.00 | 0.542458E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.233305E+11 | 0.673964E+10 | 0.627379E+11 | 0.107099E+10 | 0.849005E+10 | 1278270.02 | 0.121215E+09 | 0.313298E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.229241E+11 | 0.723738E+10 | 0.631380E+11 | 0.106772E+10 | 0.571178E+10 | 1299182.41 | 0.963207E+09 | 0.164639E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.280507E+12 | 0.718838E+11 | 0.762041E+12 | 0.129794E+11 | 0.154002E+12 | 15535293.87 | 0.389540E+10 | 0.727333E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.213320E+11 | 0.484233E+10 | 0.580684E+11 | 0.987279E+09 | 0.503658E+10 | 1186778.30 | 0.00 | 0.135071E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.251605E+11 | 0.723738E+10 | 0.666107E+11 | 0.114317E+10 | 0.197146E+11 | 1343621.24 | 0.211377E+10 | 0.106853E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [J] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [J] | COGENERATION:NATURALGAS [] | HUMIDIFIER:NATURALGAS [] | |
January | 0.00 | 0.00 | 0.114565E+10 | 0.00 | 0.840713E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.128627E+09 | 0.00 | 0.752919E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.832484E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.735235E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.729913E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.680567E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.663279E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.701965E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.687755E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.752274E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 1179479.49 | 0.00 | 0.775672E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.292619E+09 | 0.00 | 0.815836E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.156808E+10 | 0.00 | 0.896861E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.663279E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.114565E+10 | 0.00 | 0.840713E+10 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum} [W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | EXTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | FANS:ELECTRICITY {Maximum} [W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY {Maximum} [W] | PUMPS:ELECTRICITY {TIMESTAMP} | HEATING:ELECTRICITY {Maximum} [W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 26353.81 | 18-JAN-08:09 | 5557.43 | 01-JAN-06:10 | 47562.27 | 02-JAN-08:09 | 925.72 | 18-JAN-08:20 | 7715.14 | 12-JAN-15:09 | 0.73 | 02-JAN-08:09 | 60970.28 | 02-JAN-07:10 |
February | 26208.82 | 10-FEB-08:09 | 5557.43 | 01-FEB-06:10 | 47562.27 | 01-FEB-08:09 | 925.52 | 10-FEB-08:20 | 13276.08 | 22-FEB-16:10 | 0.73 | 02-FEB-08:09 | 18396.93 | 02-FEB-07:10 |
March | 26325.76 | 14-MAR-07:10 | 5557.43 | 01-MAR-06:10 | 47562.27 | 01-MAR-08:09 | 925.68 | 14-MAR-07:19 | 18494.70 | 13-MAR-15:00 | 0.73 | 01-MAR-06:30 | 5657.34 | 03-MAR-07:19 |
April | 23984.03 | 03-APR-07:10 | 5557.43 | 01-APR-05:10 | 47562.27 | 03-APR-07:10 | 922.32 | 03-APR-07:19 | 22490.46 | 17-APR-15:09 | 0.73 | 01-APR-05:30 | 0.00 | 01-APR-00:10 |
May | 24712.62 | 24-MAY-07:10 | 5557.43 | 01-MAY-05:10 | 47562.27 | 01-MAY-07:10 | 923.37 | 24-MAY-07:19 | 25817.30 | 30-MAY-14:20 | 0.73 | 01-MAY-16:10 | 0.00 | 01-MAY-00:10 |
June | 24714.71 | 23-JUN-07:10 | 5557.43 | 01-JUN-05:10 | 47562.27 | 01-JUN-07:10 | 923.37 | 23-JUN-07:19 | 26879.61 | 05-JUN-14:09 | 0.73 | 04-JUN-16:19 | 0.00 | 01-JUN-00:10 |
July | 26153.19 | 26-JUL-07:10 | 5557.43 | 01-JUL-05:10 | 47562.27 | 03-JUL-07:10 | 925.44 | 26-JUL-07:19 | 26031.98 | 05-JUL-15:09 | 0.73 | 03-JUL-17:10 | 0.00 | 01-JUL-00:10 |
August | 26369.21 | 16-AUG-07:10 | 5557.43 | 01-AUG-05:10 | 47562.27 | 01-AUG-07:10 | 925.75 | 16-AUG-07:19 | 24611.88 | 07-AUG-15:30 | 0.73 | 01-AUG-05:10 | 0.00 | 01-AUG-00:10 |
September | 26585.85 | 08-SEP-07:10 | 5557.43 | 01-SEP-05:10 | 47562.27 | 01-SEP-07:10 | 926.06 | 08-SEP-07:19 | 21660.48 | 25-SEP-15:00 | 0.73 | 01-SEP-05:19 | 0.00 | 01-SEP-00:10 |
October | 27011.40 | 11-OCT-07:10 | 5557.43 | 01-OCT-05:10 | 47562.27 | 02-OCT-07:10 | 926.67 | 11-OCT-07:19 | 18400.75 | 10-OCT-15:20 | 0.73 | 01-OCT-05:10 | 0.00 | 01-OCT-00:10 |
November | 26499.48 | 27-NOV-16:00 | 5557.43 | 01-NOV-05:10 | 47562.27 | 01-NOV-07:10 | 923.85 | 03-NOV-07:19 | 13308.17 | 01-NOV-15:00 | 0.73 | 01-NOV-05:30 | 8573.06 | 27-NOV-07:30 |
December | 26764.77 | 29-DEC-16:00 | 5557.43 | 01-DEC-06:10 | 47562.27 | 01-DEC-08:09 | 924.36 | 29-DEC-16:00 | 10017.42 | 01-DEC-15:30 | 0.73 | 21-DEC-08:09 | 22122.16 | 23-DEC-07:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 23984.03 | 5557.43 | 47562.27 | 922.32 | 7715.14 | 0.73 | 0.00 | |||||||
Maximum of Months | 27011.40 | 5557.43 | 47562.27 | 926.67 | 26879.61 | 0.73 | 60970.28 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum} [W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 23160.27 | 12-JAN-15:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 35457.60 | 22-FEB-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 64167.89 | 28-MAR-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 85789.63 | 26-APR-15:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 108704.67 | 01-MAY-15:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 111751.03 | 12-JUN-15:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 103811.23 | 03-JUL-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 97652.00 | 07-AUG-15:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 85008.46 | 14-SEP-15:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 77519.92 | 02-OCT-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 45111.77 | 06-NOV-13:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 26223.04 | 01-DEC-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 23160.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 111751.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 101465.29 | 02-JAN-07:10 | 9359.67 | 21853.28 | 5557.43 | 256.05 | 3390.39 | 0.73 | 60970.28 | 77.46 | 0.00 |
February | 115678.09 | 22-FEB-16:10 | 23688.37 | 43769.98 | 0.00 | 920.43 | 13276.08 | 0.73 | 0.00 | 34022.50 | 0.00 |
March | 149370.45 | 28-MAR-15:00 | 23688.37 | 43769.98 | 0.00 | 920.43 | 16823.06 | 0.73 | 0.00 | 64167.89 | 0.00 |
April | 171867.72 | 26-APR-15:20 | 23688.37 | 43769.98 | 0.00 | 920.43 | 18218.42 | 0.73 | 0.00 | 85269.80 | 0.00 |
May | 197436.78 | 01-MAY-15:09 | 23688.37 | 43769.98 | 0.00 | 920.43 | 20361.67 | 0.73 | 0.00 | 108695.60 | 0.00 |
June | 200684.14 | 12-JUN-14:09 | 23688.37 | 42286.04 | 0.00 | 919.86 | 26561.55 | 0.73 | 0.00 | 107227.59 | 0.00 |
July | 195124.53 | 10-JUL-12:00 | 23688.37 | 44099.74 | 0.00 | 920.56 | 23598.01 | 0.73 | 0.00 | 102817.12 | 0.00 |
August | 190641.61 | 07-AUG-15:20 | 23688.37 | 43769.98 | 0.00 | 920.43 | 24610.11 | 0.73 | 0.00 | 97652.00 | 0.00 |
September | 172523.22 | 14-SEP-15:20 | 23688.37 | 43769.98 | 0.00 | 920.43 | 19136.42 | 0.73 | 0.00 | 85007.29 | 0.00 |
October | 161551.39 | 02-OCT-15:09 | 23688.37 | 43769.98 | 0.00 | 920.43 | 15997.06 | 0.73 | 0.00 | 77174.83 | 0.00 |
November | 123833.12 | 06-NOV-13:00 | 23688.37 | 44099.74 | 0.00 | 920.56 | 10019.83 | 0.73 | 0.00 | 45103.90 | 0.00 |
December | 102761.87 | 01-DEC-15:30 | 23688.37 | 42286.04 | 0.00 | 919.86 | 10017.42 | 0.73 | 0.00 | 25849.45 | 0.00 |
Annual Sum or Average | 0.00 | ||||||||||
Minimum of Months | 101465.29 | 9359.67 | 21853.28 | 0.00 | 256.05 | 3390.39 | 0.73 | 0.00 | 77.46 | 0.00 | |
Maximum of Months | 200684.14 | 23688.37 | 44099.74 | 5557.43 | 920.56 | 26561.55 | 0.73 | 60970.28 | 108695.60 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS {Maximum} [W] | HEATING:NATURALGAS {TIMESTAMP} | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS {Maximum} [W] | WATERSYSTEMS:NATURALGAS {TIMESTAMP} | COGENERATION:NATURALGAS [] | |
January | 0.00 | 0.00 | 13926.47 | 03-JAN-06:00 | 0.00 | 8968.08 | 17-JAN-12:09 | 0.00 |
February | 0.00 | 0.00 | 7073.34 | 02-FEB-06:00 | 0.00 | 8946.21 | 01-FEB-12:30 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 8879.60 | 01-MAR-12:20 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 8740.38 | 03-APR-11:20 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 8619.31 | 01-MAY-11:09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 8483.73 | 02-JUN-11:20 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 8414.57 | 05-JUL-11:20 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 8469.20 | 30-AUG-11:20 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 8584.92 | 29-SEP-11:20 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 8729.27 | 31-OCT-11:20 | 0.00 |
November | 0.00 | 0.00 | 645.89 | 27-NOV-06:10 | 0.00 | 8857.07 | 30-NOV-12:50 | 0.00 |
December | 0.00 | 0.00 | 11025.52 | 23-DEC-06:19 | 0.00 | 8942.60 | 29-DEC-12:09 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 8414.57 | 0.00 | ||
Maximum of Months | 0.00 | 0.00 | 13926.47 | 0.00 | 8968.08 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 26.19 | 0.00 | 26.19 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 26.20 | 0.00 | 26.20 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 26.22 | 0.00 | 26.22 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 26.19 | 0.00 | 26.19 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 26.18 | 0.00 | 26.18 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 26.16 | 0.00 | 26.16 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 2.33 | 26.20 | 0.00 | 26.20 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 26.22 | 0.00 | 26.22 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 26.18 | 0.00 | 26.18 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.17 | 26.18 | 0.00 | 26.18 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 26.18 | 0.00 | 26.18 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 5.50 | 27.66 | 4.00 | 27.67 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 15.67 | 27.73 | 9.33 | 27.77 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 11.83 | 27.61 | 6.33 | 27.68 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 17.50 | 27.64 | 9.67 | 27.69 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 8.00 | 27.56 | 5.33 | 27.61 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 3.50 | 27.49 | 2.67 | 27.51 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 1.67 | 27.43 | 1.67 | 27.43 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 63.67 | 27.63 | 39.00 | 27.68 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 17.50 | 27.73 | 9.67 | 27.77 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 2.33 | 27.53 | 2.33 | 27.53 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 12.00 | 27.89 | 10.33 | 27.91 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 18.17 | 28.06 | 11.83 | 28.17 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 13.17 | 27.82 | 8.50 | 27.91 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 19.33 | 27.81 | 11.83 | 27.89 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 9.00 | 27.83 | 7.00 | 27.86 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 5.67 | 27.72 | 4.83 | 27.74 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 7.67 | 27.66 | 7.50 | 27.66 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 87.33 | 27.85 | 64.17 | 27.90 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 19.33 | 28.06 | 11.83 | 28.17 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 3.17 | 27.72 | 3.17 | 27.72 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 5.33 | 27.82 | 4.83 | 27.83 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 9.67 | 27.87 | 7.33 | 27.92 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 15.83 | 27.76 | 9.17 | 27.84 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 11.33 | 27.61 | 6.33 | 27.69 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 17.33 | 27.66 | 9.67 | 27.72 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 8.67 | 27.69 | 6.00 | 27.76 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 5.50 | 27.91 | 4.00 | 27.96 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 11.83 | 28.20 | 10.33 | 28.24 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 8.17 | 27.90 | 8.17 | 27.90 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 27.53 | 1.00 | 27.53 |
Annual Sum or Average | 0.00 | 0.00 | 97.83 | 27.80 | 70.00 | 27.86 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 17.33 | 28.20 | 10.33 | 28.24 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 27.50 | 0.50 | 27.50 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 3.17 | 27.90 | 2.33 | 27.91 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 10.33 | 28.12 | 6.00 | 28.21 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 16.67 | 28.23 | 8.83 | 28.32 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 13.50 | 28.03 | 6.83 | 28.12 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 18.33 | 27.94 | 9.67 | 27.99 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 8.00 | 27.98 | 5.17 | 28.01 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 4.33 | 28.05 | 2.67 | 28.09 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 6.50 | 28.07 | 5.33 | 28.11 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 | 27.45 | 1.17 | 27.45 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 82.50 | 28.04 | 48.50 | 28.10 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 18.33 | 28.23 | 9.67 | 28.32 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 4.83 | 27.41 | 3.33 | 27.43 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 3.83 | 27.43 | 2.33 | 27.47 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 11.17 | 27.33 | 6.50 | 27.37 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 5.50 | 27.23 | 4.00 | 27.31 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 2.17 | 27.16 | 1.83 | 27.25 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 27.50 | 27.32 | 18.00 | 27.37 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 11.17 | 27.43 | 6.50 | 27.47 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 27.32 | 0.17 | 27.32 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 6.00 | 27.65 | 5.83 | 27.65 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 11.83 | 27.78 | 9.00 | 27.84 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 7.00 | 27.61 | 5.17 | 27.67 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 17.67 | 27.52 | 11.00 | 27.59 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 8.67 | 27.49 | 6.50 | 27.56 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 5.67 | 27.47 | 4.50 | 27.54 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 6.67 | 27.55 | 6.50 | 27.55 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 63.67 | 27.58 | 48.67 | 27.64 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 17.67 | 27.78 | 11.00 | 27.84 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 18.50 | 18.78 | 18.50 | 18.78 | 0.33 | 18.85 | 0.33 | 18.93 |
February | 9.67 | 19.54 | 9.67 | 19.54 | 2.83 | 20.57 | 2.83 | 21.36 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 16.00 | 25.66 | 16.00 | 25.66 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 45.00 | 26.09 | 44.83 | 26.09 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 66.83 | 26.50 | 65.33 | 26.49 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 67.17 | 26.40 | 65.50 | 26.39 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 52.50 | 26.20 | 47.50 | 26.15 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 46.83 | 25.89 | 44.67 | 25.87 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 56.33 | 25.63 | 54.33 | 25.60 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 86.83 | 25.59 | 84.67 | 25.57 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 22.17 | 26.16 | 22.17 | 26.16 |
December | 13.33 | 19.79 | 13.33 | 19.79 | 2.83 | 20.52 | 2.83 | 21.13 |
Annual Sum or Average | 41.50 | 19.28 | 41.50 | 19.28 | 465.67 | 25.02 | 451.00 | 25.47 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 18.85 | 0.33 | 18.93 |
Maximum of Months | 18.50 | 19.79 | 18.50 | 19.79 | 86.83 | 26.50 | 84.67 | 26.49 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 27.53 | 1.00 | 27.55 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 5.83 | 27.83 | 3.83 | 27.87 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 12.00 | 27.89 | 6.00 | 27.96 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 10.33 | 27.66 | 4.67 | 27.77 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 17.17 | 27.61 | 7.67 | 27.68 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 8.17 | 27.57 | 4.50 | 27.66 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 5.00 | 27.66 | 2.67 | 27.75 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 6.00 | 27.82 | 5.00 | 27.84 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 27.38 | 0.50 | 27.38 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 66.33 | 27.70 | 35.83 | 27.77 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 17.17 | 27.89 | 7.67 | 27.96 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 3.17 | 27.45 | 2.33 | 27.46 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 10.50 | 27.54 | 7.00 | 27.56 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 7.00 | 27.38 | 4.00 | 27.44 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 12.83 | 27.39 | 8.17 | 27.43 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 4.67 | 27.30 | 3.83 | 27.36 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 27.36 | 0.83 | 27.36 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 39.00 | 27.42 | 26.17 | 27.46 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 12.83 | 27.54 | 8.17 | 27.56 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 27.31 | 0.17 | 27.31 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 27.56 | 1.33 | 27.56 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 8.50 | 27.82 | 7.67 | 27.84 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 15.00 | 27.89 | 11.67 | 27.95 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 9.17 | 27.66 | 7.17 | 27.70 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 15.33 | 27.61 | 11.50 | 27.67 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 7.00 | 27.61 | 6.50 | 27.63 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 4.00 | 27.60 | 3.83 | 27.61 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 4.33 | 27.65 | 4.33 | 27.65 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 64.83 | 27.71 | 54.17 | 27.75 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 15.33 | 27.89 | 11.67 | 27.95 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 27.33 | 0.33 | 27.33 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 3.50 | 27.65 | 3.50 | 27.65 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 4.83 | 27.66 | 4.67 | 27.67 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 7.00 | 27.72 | 5.67 | 27.75 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 11.67 | 27.56 | 7.83 | 27.62 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 6.67 | 27.37 | 4.17 | 27.45 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 12.67 | 27.42 | 8.50 | 27.47 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 6.50 | 27.44 | 5.17 | 27.51 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 4.33 | 27.72 | 3.33 | 27.78 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 13.33 | 27.62 | 12.33 | 27.63 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 8.83 | 27.83 | 8.83 | 27.83 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 1.67 | 27.55 | 1.67 | 27.55 |
Annual Sum or Average | 0.00 | 0.00 | 81.33 | 27.58 | 66.00 | 27.62 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 27.33 | 0.33 | 27.33 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 13.33 | 27.83 | 12.33 | 27.83 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 27.45 | 0.33 | 27.45 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 2.83 | 27.71 | 2.17 | 27.73 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 8.17 | 27.99 | 5.00 | 28.05 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 13.50 | 28.05 | 7.33 | 28.13 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 10.00 | 27.87 | 5.00 | 27.97 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 12.83 | 27.78 | 7.00 | 27.86 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 5.67 | 27.79 | 3.67 | 27.85 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 3.33 | 27.94 | 2.00 | 27.98 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 5.50 | 27.91 | 4.67 | 27.94 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 27.43 | 0.83 | 27.43 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 63.00 | 27.89 | 38.00 | 27.95 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 13.50 | 28.05 | 7.33 | 28.13 |
Report: ComfortReportSimple55Monthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 45.50 | 23.88 | 133.83 | 24.65 | 7.17 | 24.65 |
February | 8.33 | 23.86 | 246.17 | 24.60 | 0.00 | 24.60 |
March | 0.00 | 0.00 | 407.67 | 24.43 | 0.00 | 24.43 |
April | 0.00 | 0.00 | 436.83 | 24.45 | 0.00 | 24.45 |
May | 0.00 | 0.00 | 503.00 | 24.40 | 0.00 | 24.40 |
June | 0.00 | 0.00 | 496.00 | 24.37 | 0.00 | 24.37 |
July | 0.00 | 0.00 | 497.00 | 24.43 | 0.00 | 24.43 |
August | 0.00 | 0.00 | 514.00 | 24.39 | 0.00 | 24.39 |
September | 0.00 | 0.00 | 485.00 | 24.46 | 0.00 | 24.46 |
October | 0.00 | 0.00 | 501.50 | 24.46 | 0.00 | 24.46 |
November | 0.00 | 0.00 | 407.50 | 24.48 | 0.00 | 24.48 |
December | 14.83 | 23.92 | 177.83 | 24.67 | 0.00 | 24.67 |
Annual Sum or Average | 68.67 | 23.89 | 4806.33 | 24.45 | 7.17 | 24.45 |
Minimum of Months | 0.00 | 0.00 | 133.83 | 24.37 | 0.00 | 24.37 |
Maximum of Months | 45.50 | 23.92 | 514.00 | 24.67 | 7.17 | 24.67 |
Report: ComfortReportSimple55Monthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 330.67 | 23.25 | 4.00 | 23.26 | 0.00 | 23.26 |
February | 139.17 | 23.44 | 106.67 | 23.86 | 0.00 | 23.86 |
March | 20.67 | 23.67 | 319.83 | 24.28 | 0.00 | 24.28 |
April | 0.00 | 0.00 | 410.83 | 24.36 | 0.00 | 24.36 |
May | 0.00 | 0.00 | 495.67 | 24.34 | 0.00 | 24.34 |
June | 0.00 | 0.00 | 496.00 | 24.30 | 0.00 | 24.30 |
July | 0.00 | 0.00 | 497.00 | 24.36 | 0.00 | 24.36 |
August | 0.00 | 0.00 | 514.00 | 24.32 | 0.00 | 24.32 |
September | 2.17 | 27.15 | 485.00 | 24.38 | 2.17 | 24.40 |
October | 0.00 | 0.00 | 466.00 | 24.35 | 0.00 | 24.35 |
November | 37.50 | 23.58 | 246.50 | 24.27 | 0.00 | 24.27 |
December | 256.50 | 23.43 | 22.00 | 23.51 | 0.00 | 23.51 |
Annual Sum or Average | 786.67 | 23.38 | 4063.50 | 24.19 | 2.17 | 24.19 |
Minimum of Months | 0.00 | 0.00 | 4.00 | 23.26 | 0.00 | 23.26 |
Maximum of Months | 330.67 | 27.15 | 514.00 | 24.38 | 2.17 | 24.40 |
Report: ComfortReportSimple55Monthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 453.83 | 22.53 | 7.33 | 22.48 | 7.33 | 22.44 |
February | 275.17 | 23.04 | 57.33 | 23.23 | 0.00 | 23.23 |
March | 95.83 | 23.47 | 258.50 | 24.02 | 0.00 | 24.02 |
April | 3.83 | 23.90 | 403.33 | 24.38 | 0.33 | 24.38 |
May | 1.17 | 26.59 | 505.00 | 24.39 | 1.17 | 24.40 |
June | 0.50 | 26.62 | 496.00 | 24.33 | 0.50 | 24.34 |
July | 1.00 | 26.59 | 497.00 | 24.43 | 1.00 | 24.43 |
August | 0.00 | 0.00 | 514.00 | 24.35 | 0.00 | 24.35 |
September | 1.50 | 27.16 | 483.33 | 24.38 | 1.50 | 24.39 |
October | 17.67 | 23.36 | 407.67 | 24.29 | 0.00 | 24.29 |
November | 177.83 | 23.27 | 139.83 | 23.64 | 0.00 | 23.64 |
December | 411.67 | 22.80 | 1.67 | 22.80 | 0.00 | 22.80 |
Annual Sum or Average | 1440.00 | 22.88 | 3771.00 | 23.94 | 11.83 | 23.93 |
Minimum of Months | 0.00 | 0.00 | 1.67 | 22.48 | 0.00 | 22.44 |
Maximum of Months | 453.83 | 27.16 | 514.00 | 24.43 | 7.33 | 24.43 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 485.50 | 21.76 | 59.83 | 21.56 | 59.83 | 21.40 |
February | 327.17 | 22.42 | 65.50 | 22.60 | 10.50 | 22.53 |
March | 142.33 | 23.06 | 254.83 | 23.81 | 0.50 | 23.81 |
April | 30.83 | 25.14 | 417.67 | 24.56 | 14.83 | 24.63 |
May | 44.00 | 26.85 | 508.00 | 24.76 | 44.00 | 24.91 |
June | 52.00 | 26.55 | 496.00 | 24.72 | 52.00 | 24.88 |
July | 105.33 | 26.40 | 497.00 | 24.96 | 105.33 | 25.17 |
August | 75.67 | 26.21 | 514.00 | 24.72 | 75.67 | 24.89 |
September | 58.00 | 26.23 | 484.17 | 24.68 | 58.00 | 24.83 |
October | 64.67 | 23.58 | 379.67 | 24.26 | 7.83 | 24.30 |
November | 266.17 | 22.81 | 124.50 | 23.22 | 0.00 | 23.22 |
December | 448.67 | 21.99 | 36.00 | 21.85 | 36.00 | 21.73 |
Annual Sum or Average | 2100.33 | 22.98 | 3837.17 | 23.87 | 464.50 | 23.95 |
Minimum of Months | 30.83 | 21.76 | 36.00 | 21.56 | 0.00 | 21.40 |
Maximum of Months | 485.50 | 26.85 | 514.00 | 24.96 | 105.33 | 25.17 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 444.67 | 22.03 | 39.33 | 21.87 | 37.83 | 21.72 |
February | 250.50 | 22.50 | 117.83 | 22.98 | 7.83 | 22.92 |
March | 110.50 | 23.29 | 327.83 | 24.08 | 8.33 | 24.13 |
April | 49.67 | 26.07 | 441.33 | 24.73 | 37.17 | 24.89 |
May | 56.17 | 26.99 | 508.00 | 24.85 | 56.17 | 25.04 |
June | 54.67 | 26.71 | 496.00 | 24.75 | 54.67 | 24.93 |
July | 106.17 | 26.49 | 497.00 | 24.98 | 106.17 | 25.21 |
August | 75.67 | 26.31 | 514.00 | 24.73 | 75.67 | 24.91 |
September | 64.33 | 26.31 | 483.00 | 24.72 | 64.33 | 24.89 |
October | 76.00 | 24.54 | 407.00 | 24.50 | 30.33 | 24.64 |
November | 192.83 | 22.78 | 217.67 | 23.58 | 0.00 | 23.58 |
December | 394.50 | 22.26 | 29.17 | 22.16 | 23.33 | 22.05 |
Annual Sum or Average | 1875.67 | 23.36 | 4078.17 | 24.10 | 501.83 | 24.22 |
Minimum of Months | 49.67 | 22.03 | 29.17 | 21.87 | 0.00 | 21.72 |
Maximum of Months | 444.67 | 26.99 | 514.00 | 24.98 | 106.17 | 25.21 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 307.33 | 21.99 | 138.17 | 22.38 | 36.00 | 22.20 |
February | 214.50 | 22.66 | 179.67 | 23.45 | 13.83 | 23.46 |
March | 115.50 | 23.61 | 320.83 | 24.18 | 17.17 | 24.28 |
April | 42.33 | 25.79 | 426.50 | 24.68 | 27.50 | 24.81 |
May | 43.67 | 26.90 | 508.00 | 24.76 | 43.67 | 24.92 |
June | 51.00 | 26.54 | 496.00 | 24.71 | 51.00 | 24.87 |
July | 103.00 | 26.40 | 497.00 | 24.95 | 103.00 | 25.16 |
August | 75.33 | 26.25 | 514.00 | 24.73 | 75.33 | 24.90 |
September | 62.33 | 26.37 | 485.00 | 24.74 | 62.33 | 24.91 |
October | 79.17 | 25.18 | 423.17 | 24.66 | 41.00 | 24.84 |
November | 171.33 | 23.53 | 264.67 | 24.16 | 27.00 | 24.33 |
December | 261.00 | 22.21 | 163.33 | 22.99 | 15.17 | 22.91 |
Annual Sum or Average | 1526.50 | 23.67 | 4416.33 | 24.28 | 513.00 | 24.40 |
Minimum of Months | 42.33 | 21.99 | 138.17 | 22.38 | 13.83 | 22.20 |
Maximum of Months | 307.33 | 26.90 | 514.00 | 24.95 | 103.00 | 25.16 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 427.67 | 21.67 | 74.83 | 21.56 | 58.33 | 21.39 |
February | 298.00 | 22.27 | 112.17 | 22.75 | 10.00 | 22.70 |
March | 149.50 | 23.10 | 285.33 | 23.89 | 8.50 | 23.95 |
April | 49.67 | 25.38 | 426.17 | 24.64 | 27.50 | 24.77 |
May | 53.00 | 26.99 | 507.33 | 24.81 | 53.00 | 25.00 |
June | 58.33 | 26.69 | 496.00 | 24.76 | 58.33 | 24.94 |
July | 104.00 | 26.45 | 497.00 | 24.96 | 104.00 | 25.18 |
August | 74.50 | 26.27 | 514.00 | 24.71 | 74.50 | 24.89 |
September | 60.33 | 26.27 | 480.00 | 24.69 | 60.33 | 24.85 |
October | 84.50 | 23.96 | 382.67 | 24.35 | 21.00 | 24.46 |
November | 248.00 | 22.68 | 173.50 | 23.35 | 2.50 | 23.37 |
December | 398.83 | 21.90 | 79.50 | 21.97 | 36.50 | 21.83 |
Annual Sum or Average | 2006.33 | 23.07 | 4028.50 | 23.95 | 514.50 | 24.05 |
Minimum of Months | 49.67 | 21.67 | 74.83 | 21.56 | 2.50 | 21.39 |
Maximum of Months | 427.67 | 26.99 | 514.00 | 24.96 | 104.00 | 25.18 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 462.50 | 22.65 | 2.67 | 22.66 | 0.00 | 22.66 |
February | 308.33 | 22.99 | 51.33 | 23.16 | 0.00 | 23.16 |
March | 136.00 | 23.35 | 224.67 | 23.86 | 0.00 | 23.86 |
April | 15.67 | 23.78 | 399.33 | 24.39 | 0.67 | 24.40 |
May | 15.67 | 26.65 | 508.00 | 24.58 | 15.67 | 24.64 |
June | 30.50 | 26.40 | 496.00 | 24.61 | 30.50 | 24.71 |
July | 76.33 | 26.47 | 497.00 | 24.88 | 76.33 | 25.07 |
August | 49.33 | 26.47 | 514.00 | 24.69 | 49.33 | 24.83 |
September | 41.33 | 26.50 | 485.00 | 24.70 | 41.33 | 24.83 |
October | 1.33 | 24.85 | 473.00 | 24.41 | 0.50 | 24.42 |
November | 108.50 | 23.45 | 223.67 | 23.96 | 0.00 | 23.96 |
December | 380.33 | 23.03 | 10.17 | 23.06 | 0.00 | 23.06 |
Annual Sum or Average | 1625.83 | 23.43 | 3884.83 | 24.16 | 214.33 | 24.25 |
Minimum of Months | 1.33 | 22.65 | 2.67 | 22.66 | 0.00 | 22.66 |
Maximum of Months | 462.50 | 26.65 | 514.00 | 24.88 | 76.33 | 25.07 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 344.33 | 22.90 | 24.67 | 22.92 | 12.33 | 22.90 |
February | 184.67 | 23.06 | 137.50 | 23.61 | 0.00 | 23.61 |
March | 73.17 | 23.37 | 330.67 | 24.16 | 0.50 | 24.16 |
April | 20.50 | 26.20 | 439.83 | 24.62 | 15.50 | 24.70 |
May | 47.83 | 26.87 | 508.00 | 24.79 | 47.83 | 24.95 |
June | 45.33 | 26.67 | 496.00 | 24.72 | 45.33 | 24.87 |
July | 87.67 | 26.61 | 497.00 | 24.96 | 87.67 | 25.18 |
August | 58.00 | 26.62 | 514.00 | 24.75 | 58.00 | 24.92 |
September | 50.50 | 26.61 | 485.00 | 24.77 | 50.50 | 24.93 |
October | 24.33 | 26.89 | 487.00 | 24.66 | 24.33 | 24.76 |
November | 53.17 | 23.44 | 332.33 | 24.25 | 0.00 | 24.25 |
December | 253.67 | 23.15 | 66.17 | 23.39 | 0.00 | 23.39 |
Annual Sum or Average | 1243.17 | 24.03 | 4318.17 | 24.41 | 342.00 | 24.54 |
Minimum of Months | 20.50 | 22.90 | 24.67 | 22.92 | 0.00 | 22.90 |
Maximum of Months | 344.33 | 26.89 | 514.00 | 24.96 | 87.67 | 25.18 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 280.17 | 22.46 | 128.00 | 22.94 | 20.33 | 22.86 |
February | 149.50 | 22.46 | 201.33 | 23.64 | 5.00 | 23.63 |
March | 80.50 | 23.04 | 331.17 | 24.19 | 6.33 | 24.23 |
April | 33.00 | 25.38 | 430.83 | 24.77 | 22.67 | 24.85 |
May | 94.83 | 25.87 | 508.00 | 25.02 | 94.83 | 25.13 |
June | 160.83 | 25.35 | 496.00 | 24.96 | 160.83 | 25.04 |
July | 261.83 | 25.09 | 497.00 | 24.92 | 261.83 | 24.96 |
August | 273.83 | 24.83 | 514.00 | 24.73 | 273.83 | 24.75 |
September | 202.67 | 25.01 | 485.00 | 24.84 | 202.67 | 24.88 |
October | 89.17 | 25.75 | 488.50 | 24.98 | 84.17 | 25.11 |
November | 71.00 | 24.12 | 390.17 | 24.59 | 27.67 | 24.73 |
December | 178.00 | 22.68 | 191.17 | 23.70 | 3.33 | 23.69 |
Annual Sum or Average | 1875.33 | 24.19 | 4661.17 | 24.57 | 1163.50 | 24.66 |
Minimum of Months | 33.00 | 22.46 | 128.00 | 22.94 | 3.33 | 22.86 |
Maximum of Months | 280.17 | 25.87 | 514.00 | 25.02 | 273.83 | 25.13 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 378.33 | 22.73 | 38.00 | 22.81 | 12.17 | 22.79 |
February | 232.83 | 22.97 | 117.67 | 23.43 | 0.00 | 23.43 |
March | 92.33 | 23.40 | 301.83 | 24.09 | 2.17 | 24.11 |
April | 18.33 | 26.35 | 438.33 | 24.59 | 14.83 | 24.67 |
May | 38.00 | 26.92 | 508.00 | 24.75 | 38.00 | 24.89 |
June | 51.83 | 26.73 | 496.00 | 24.76 | 51.83 | 24.93 |
July | 87.83 | 26.58 | 497.00 | 24.95 | 87.83 | 25.17 |
August | 58.33 | 26.60 | 514.00 | 24.75 | 58.33 | 24.92 |
September | 51.67 | 26.62 | 485.00 | 24.79 | 51.67 | 24.95 |
October | 19.33 | 26.98 | 482.83 | 24.62 | 19.33 | 24.70 |
November | 70.00 | 23.48 | 304.00 | 24.20 | 0.83 | 24.21 |
December | 303.33 | 23.10 | 80.00 | 23.34 | 0.00 | 23.34 |
Annual Sum or Average | 1402.17 | 23.85 | 4262.67 | 24.35 | 337.00 | 24.47 |
Minimum of Months | 18.33 | 22.73 | 38.00 | 22.81 | 0.00 | 22.79 |
Maximum of Months | 378.33 | 26.98 | 514.00 | 24.95 | 87.83 | 25.17 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 458.50 | 22.45 | 5.83 | 22.43 | 4.33 | 22.41 |
February | 268.50 | 22.95 | 70.17 | 23.20 | 0.00 | 23.20 |
March | 84.17 | 23.44 | 290.50 | 24.06 | 0.00 | 24.06 |
April | 9.17 | 26.28 | 426.83 | 24.55 | 7.33 | 24.59 |
May | 36.50 | 26.76 | 508.00 | 24.72 | 36.50 | 24.85 |
June | 48.83 | 26.41 | 496.00 | 24.69 | 48.83 | 24.83 |
July | 104.17 | 26.32 | 497.00 | 24.93 | 104.17 | 25.14 |
August | 72.67 | 26.16 | 514.00 | 24.70 | 72.67 | 24.86 |
September | 58.50 | 26.22 | 485.00 | 24.69 | 58.50 | 24.84 |
October | 16.00 | 23.61 | 439.17 | 24.35 | 0.83 | 24.36 |
November | 169.00 | 23.29 | 162.00 | 23.70 | 0.00 | 23.70 |
December | 406.50 | 22.71 | 2.67 | 22.72 | 0.00 | 22.72 |
Annual Sum or Average | 1732.50 | 23.47 | 3897.17 | 24.16 | 333.17 | 24.28 |
Minimum of Months | 9.17 | 22.45 | 2.67 | 22.43 | 0.00 | 22.41 |
Maximum of Months | 458.50 | 26.76 | 514.00 | 24.93 | 104.17 | 25.14 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 350.67 | 22.51 | 7.83 | 22.51 | 3.00 | 22.49 |
February | 186.33 | 22.90 | 103.33 | 23.46 | 0.00 | 23.46 |
March | 67.83 | 23.57 | 278.33 | 24.27 | 4.50 | 24.31 |
April | 31.50 | 26.79 | 369.50 | 24.86 | 30.00 | 25.01 |
May | 54.50 | 26.91 | 430.00 | 24.96 | 54.50 | 25.16 |
June | 52.33 | 26.59 | 418.00 | 24.85 | 52.33 | 25.02 |
July | 104.50 | 26.41 | 422.00 | 25.09 | 104.50 | 25.31 |
August | 73.33 | 26.27 | 433.00 | 24.83 | 73.33 | 25.01 |
September | 64.33 | 26.32 | 410.00 | 24.84 | 64.33 | 25.02 |
October | 37.17 | 25.47 | 375.67 | 24.67 | 22.67 | 24.79 |
November | 125.17 | 23.20 | 194.17 | 23.94 | 0.00 | 23.94 |
December | 292.83 | 22.70 | 15.00 | 22.79 | 0.00 | 22.79 |
Annual Sum or Average | 1440.50 | 23.84 | 3456.83 | 24.39 | 409.17 | 24.55 |
Minimum of Months | 31.50 | 22.51 | 7.83 | 22.51 | 0.00 | 22.49 |
Maximum of Months | 350.67 | 26.91 | 433.00 | 25.09 | 104.50 | 25.31 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 265.00 | 22.70 | 138.17 | 23.27 | 1.00 | 23.27 |
February | 150.67 | 23.17 | 201.67 | 23.96 | 6.50 | 24.01 |
March | 65.00 | 24.19 | 354.67 | 24.36 | 14.00 | 24.45 |
April | 23.50 | 26.75 | 438.50 | 24.68 | 21.83 | 24.78 |
May | 40.17 | 26.80 | 508.00 | 24.74 | 40.17 | 24.88 |
June | 47.83 | 26.41 | 496.00 | 24.69 | 47.83 | 24.82 |
July | 102.83 | 26.32 | 497.00 | 24.93 | 102.83 | 25.13 |
August | 72.67 | 26.22 | 514.00 | 24.71 | 72.67 | 24.88 |
September | 62.50 | 26.36 | 485.00 | 24.75 | 62.50 | 24.92 |
October | 50.83 | 26.41 | 465.17 | 24.76 | 41.67 | 24.93 |
November | 98.83 | 24.32 | 316.83 | 24.52 | 26.83 | 24.67 |
December | 212.67 | 22.95 | 180.50 | 23.73 | 1.67 | 23.75 |
Annual Sum or Average | 1192.50 | 24.26 | 4595.50 | 24.49 | 439.50 | 24.63 |
Minimum of Months | 23.50 | 22.70 | 138.17 | 23.27 | 1.00 | 23.27 |
Maximum of Months | 265.00 | 26.80 | 514.00 | 24.93 | 102.83 | 25.13 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 396.67 | 22.34 | 29.33 | 22.45 | 1.83 | 22.44 |
February | 243.67 | 22.82 | 121.83 | 23.34 | 0.17 | 23.34 |
March | 89.17 | 23.53 | 322.83 | 24.15 | 6.50 | 24.19 |
April | 23.83 | 26.76 | 443.00 | 24.66 | 22.00 | 24.77 |
May | 45.50 | 26.93 | 508.00 | 24.78 | 45.50 | 24.95 |
June | 58.00 | 26.60 | 496.00 | 24.76 | 58.00 | 24.93 |
July | 105.67 | 26.35 | 497.00 | 24.94 | 105.67 | 25.15 |
August | 73.50 | 26.22 | 514.00 | 24.71 | 73.50 | 24.88 |
September | 59.17 | 26.27 | 485.00 | 24.71 | 59.17 | 24.86 |
October | 39.00 | 25.12 | 437.83 | 24.51 | 19.50 | 24.60 |
November | 155.17 | 23.18 | 222.33 | 23.85 | 1.17 | 23.86 |
December | 358.83 | 22.62 | 62.33 | 22.85 | 0.00 | 22.85 |
Annual Sum or Average | 1648.17 | 23.59 | 4139.50 | 24.24 | 393.00 | 24.38 |
Minimum of Months | 23.83 | 22.34 | 29.33 | 22.45 | 0.00 | 22.44 |
Maximum of Months | 396.67 | 26.93 | 514.00 | 24.94 | 105.67 | 25.15 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 24.29754 | 36.79397 | 0.39508 | 8.46819 |
February | 454.00000 | 24.36598 | 39.21422 | 0.45155 | 9.49691 |
March | 514.00000 | 24.35168 | 43.23774 | 0.50346 | 10.52908 |
April | 485.00000 | 24.41064 | 44.20081 | 0.54045 | 11.36924 |
May | 508.00000 | 24.39933 | 49.90711 | -0.2530 | 6.81615 |
June | 496.00000 | 24.37051 | 52.33837 | -0.2457 | 6.73336 |
July | 497.00000 | 24.42639 | 53.63935 | -0.2242 | 6.58349 |
August | 514.00000 | 24.39076 | 53.63603 | -0.2321 | 6.66887 |
September | 485.00000 | 24.45555 | 53.34336 | -0.2178 | 6.65112 |
October | 502.00000 | 24.45705 | 48.54407 | 0.57951 | 12.31218 |
November | 489.00000 | 24.40946 | 42.24232 | 0.50759 | 10.61543 |
December | 497.00000 | 24.33384 | 36.36017 | 0.41857 | 8.83373 |
Annual Sum or Average | 5943.00000 | 24.38892 | 46.17935 | 0.18250 | 8.74619 |
Minimum of Months | 454.00000 | 24.29754 | 36.36017 | -0.2530 | 6.58349 |
Maximum of Months | 514.00000 | 24.45705 | 53.63935 | 0.57951 | 12.31218 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 23.55219 | 39.29903 | 0.20467 | 6.29626 |
February | 454.00000 | 23.94437 | 40.71720 | 0.33603 | 7.71035 |
March | 514.00000 | 24.18098 | 44.44447 | 0.45074 | 9.44221 |
April | 485.00000 | 24.30827 | 45.87373 | 0.51320 | 10.72422 |
May | 508.00000 | 24.32795 | 52.14337 | -0.2796 | 7.00826 |
June | 496.00000 | 24.29946 | 54.97976 | -0.2710 | 6.88020 |
July | 497.00000 | 24.35824 | 56.14802 | -0.2487 | 6.72914 |
August | 514.00000 | 24.32157 | 56.45024 | -0.2609 | 6.83567 |
September | 485.00000 | 24.37161 | 55.93449 | -0.2558 | 6.92266 |
October | 502.00000 | 24.32282 | 49.92116 | 0.53625 | 11.22067 |
November | 489.00000 | 24.15765 | 43.05098 | 0.42459 | 8.96027 |
December | 497.00000 | 23.76795 | 38.00552 | 0.26321 | 6.77172 |
Annual Sum or Average | 5943.00000 | 24.16069 | 48.14337 | 0.11532 | 7.95623 |
Minimum of Months | 454.00000 | 23.55219 | 38.00552 | -0.2796 | 6.29626 |
Maximum of Months | 514.00000 | 24.37161 | 56.45024 | 0.53625 | 11.22067 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 22.66693 | 40.56154 | -0.0145 | 6.13918 |
February | 454.00000 | 23.44914 | 40.93895 | 0.20832 | 6.76108 |
March | 514.00000 | 24.03260 | 43.52922 | 0.40844 | 8.84347 |
April | 485.00000 | 24.32011 | 45.36769 | 0.52627 | 11.07901 |
May | 508.00000 | 24.38476 | 51.80813 | -0.2344 | 6.70537 |
June | 496.00000 | 24.33149 | 54.79756 | -0.2300 | 6.55238 |
July | 497.00000 | 24.42401 | 56.14158 | -0.2046 | 6.52869 |
August | 514.00000 | 24.35292 | 56.58736 | -0.2311 | 6.63476 |
September | 485.00000 | 24.37186 | 55.97592 | -0.2444 | 6.83468 |
October | 502.00000 | 24.23254 | 49.37254 | 0.51048 | 10.70933 |
November | 489.00000 | 23.78644 | 42.91503 | 0.32382 | 7.65814 |
December | 497.00000 | 22.99886 | 38.85534 | 0.06801 | 6.05353 |
Annual Sum or Average | 5943.00000 | 23.94949 | 48.13088 | 0.07214 | 7.54264 |
Minimum of Months | 454.00000 | 22.66693 | 38.85534 | -0.2444 | 6.05353 |
Maximum of Months | 514.00000 | 24.42401 | 56.58736 | 0.52627 | 11.07901 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 21.83047 | 43.95654 | -0.2134 | 7.78651 |
February | 454.00000 | 22.87136 | 43.61498 | 0.07601 | 6.95095 |
March | 514.00000 | 23.85712 | 44.55159 | 0.37663 | 8.89271 |
April | 485.00000 | 24.42714 | 45.23006 | 0.58351 | 12.80387 |
May | 508.00000 | 24.57732 | 51.63615 | -0.0909 | 6.54646 |
June | 496.00000 | 24.52683 | 54.87929 | -0.0743 | 6.35097 |
July | 497.00000 | 24.65363 | 57.04358 | -0.0433 | 6.86476 |
August | 514.00000 | 24.49636 | 57.42383 | -0.1119 | 6.53621 |
September | 485.00000 | 24.49310 | 57.16140 | -0.1514 | 6.76327 |
October | 502.00000 | 24.18210 | 49.81852 | 0.51031 | 11.14943 |
November | 489.00000 | 23.36900 | 44.60242 | 0.22490 | 7.31055 |
December | 497.00000 | 22.18286 | 41.68333 | -0.1266 | 7.17932 |
Annual Sum or Average | 5943.00000 | 23.79567 | 49.34892 | 0.07938 | 7.92740 |
Minimum of Months | 454.00000 | 21.83047 | 41.68333 | -0.2134 | 6.35097 |
Maximum of Months | 514.00000 | 24.65363 | 57.42383 | 0.58351 | 12.80387 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 22.24885 | 43.19198 | -0.0964 | 7.13837 |
February | 454.00000 | 23.24008 | 42.53254 | 0.18772 | 7.60418 |
March | 514.00000 | 24.02311 | 43.87735 | 0.45761 | 10.53362 |
April | 485.00000 | 24.51119 | 44.88834 | 0.66177 | 15.14659 |
May | 508.00000 | 24.60814 | 51.43890 | -0.0070 | 6.78845 |
June | 496.00000 | 24.53583 | 54.76733 | -0.0235 | 6.44874 |
July | 497.00000 | 24.66263 | 56.94462 | -0.0082 | 7.06791 |
August | 514.00000 | 24.50241 | 57.36025 | -0.0813 | 6.57646 |
September | 485.00000 | 24.50122 | 57.02031 | -0.1071 | 6.68245 |
October | 502.00000 | 24.30360 | 49.33371 | 0.57733 | 13.04203 |
November | 489.00000 | 23.64547 | 43.66255 | 0.31872 | 8.52481 |
December | 497.00000 | 22.61753 | 40.76169 | -0.0081 | 6.95871 |
Annual Sum or Average | 5943.00000 | 23.95508 | 48.86860 | 0.15507 | 8.53971 |
Minimum of Months | 454.00000 | 22.24885 | 40.76169 | -0.1071 | 6.44874 |
Maximum of Months | 514.00000 | 24.66263 | 57.36025 | 0.66177 | 15.14659 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 22.85740 | 40.60922 | 0.07057 | 8.23577 |
February | 454.00000 | 23.53064 | 41.24425 | 0.28021 | 9.33146 |
March | 514.00000 | 24.06431 | 43.50569 | 0.47918 | 11.20881 |
April | 485.00000 | 24.48038 | 44.91506 | 0.63014 | 14.22980 |
May | 508.00000 | 24.57686 | 51.59565 | -0.0808 | 6.59375 |
June | 496.00000 | 24.52124 | 54.89274 | -0.0778 | 6.36891 |
July | 497.00000 | 24.65061 | 57.03341 | -0.0426 | 6.88379 |
August | 514.00000 | 24.50433 | 57.31391 | -0.0970 | 6.57545 |
September | 485.00000 | 24.53238 | 56.79788 | -0.0957 | 6.76151 |
October | 502.00000 | 24.40419 | 48.71771 | 0.63470 | 14.85259 |
November | 489.00000 | 23.98398 | 42.11280 | 0.44990 | 11.52947 |
December | 497.00000 | 23.25446 | 38.30702 | 0.17257 | 8.73144 |
Annual Sum or Average | 5943.00000 | 24.11716 | 48.14636 | 0.19214 | 9.26401 |
Minimum of Months | 454.00000 | 22.85740 | 38.30702 | -0.0970 | 6.36891 |
Maximum of Months | 514.00000 | 24.65061 | 57.31391 | 0.63470 | 14.85259 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 22.02750 | 43.25051 | -0.1464 | 7.93051 |
February | 454.00000 | 22.93855 | 43.11488 | 0.11911 | 7.79190 |
March | 514.00000 | 23.85855 | 44.28297 | 0.41765 | 10.12054 |
April | 485.00000 | 24.44756 | 45.08146 | 0.64010 | 14.65363 |
May | 508.00000 | 24.58352 | 51.56766 | -0.0297 | 6.95665 |
June | 496.00000 | 24.52931 | 54.84201 | -0.0212 | 6.64369 |
July | 497.00000 | 24.64295 | 57.04679 | -0.0215 | 7.07826 |
August | 514.00000 | 24.48889 | 57.44995 | -0.0893 | 6.62584 |
September | 485.00000 | 24.48400 | 57.09590 | -0.1143 | 6.82515 |
October | 502.00000 | 24.18705 | 49.66362 | 0.54801 | 12.48500 |
November | 489.00000 | 23.41760 | 44.13089 | 0.27047 | 8.43737 |
December | 497.00000 | 22.33374 | 40.95285 | -0.0693 | 7.52353 |
Annual Sum or Average | 5943.00000 | 23.83473 | 49.09097 | 0.12469 | 8.58542 |
Minimum of Months | 454.00000 | 22.02750 | 40.95285 | -0.1464 | 6.62584 |
Maximum of Months | 514.00000 | 24.64295 | 57.44995 | 0.64010 | 14.65363 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 22.75263 | 42.68323 | 0.02254 | 5.88690 |
February | 454.00000 | 23.32269 | 43.76841 | 0.18503 | 6.55467 |
March | 514.00000 | 23.90910 | 45.66345 | 0.37258 | 8.33002 |
April | 485.00000 | 24.33166 | 44.97938 | 0.51969 | 10.96311 |
May | 508.00000 | 24.51110 | 50.24093 | -0.1737 | 6.46909 |
June | 496.00000 | 24.50002 | 52.68994 | -0.1332 | 6.27302 |
July | 497.00000 | 24.64196 | 54.18839 | -0.0746 | 6.54337 |
August | 514.00000 | 24.51882 | 54.13674 | -0.1176 | 6.38271 |
September | 485.00000 | 24.55039 | 54.14136 | -0.1345 | 6.50243 |
October | 502.00000 | 24.38515 | 49.26746 | 0.56819 | 12.05129 |
November | 489.00000 | 23.98183 | 44.43374 | 0.38674 | 8.42754 |
December | 497.00000 | 23.25465 | 40.53580 | 0.14496 | 6.08703 |
Annual Sum or Average | 5943.00000 | 24.05970 | 48.10089 | 0.12926 | 7.53997 |
Minimum of Months | 454.00000 | 22.75263 | 40.53580 | -0.1737 | 5.88690 |
Maximum of Months | 514.00000 | 24.64196 | 54.18839 | 0.56819 | 12.05129 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 23.25012 | 41.72000 | 0.15617 | 6.31299 |
February | 454.00000 | 23.73143 | 42.54003 | 0.30703 | 7.77657 |
March | 514.00000 | 24.12999 | 44.71323 | 0.46543 | 10.11749 |
April | 485.00000 | 24.48853 | 44.33402 | 0.61348 | 13.50569 |
May | 508.00000 | 24.59436 | 49.85186 | -0.0715 | 6.39360 |
June | 496.00000 | 24.53605 | 52.49268 | -0.0730 | 6.23205 |
July | 497.00000 | 24.67115 | 54.07103 | -0.0323 | 6.71065 |
August | 514.00000 | 24.54060 | 54.06052 | -0.0813 | 6.39209 |
September | 485.00000 | 24.58224 | 53.96834 | -0.0819 | 6.39549 |
October | 502.00000 | 24.52516 | 48.73163 | 0.64024 | 14.17694 |
November | 489.00000 | 24.20994 | 43.60252 | 0.47281 | 10.11910 |
December | 497.00000 | 23.62830 | 39.51597 | 0.25222 | 6.94362 |
Annual Sum or Average | 5943.00000 | 24.24374 | 47.51165 | 0.21242 | 8.41796 |
Minimum of Months | 454.00000 | 23.25012 | 39.51597 | -0.0819 | 6.23205 |
Maximum of Months | 514.00000 | 24.67115 | 54.07103 | 0.64024 | 14.17694 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 23.25296 | 39.59962 | 0.21165 | 7.84054 |
February | 454.00000 | 23.74524 | 41.43118 | 0.35129 | 9.37202 |
March | 514.00000 | 24.12611 | 43.91621 | 0.47969 | 10.80353 |
April | 485.00000 | 24.62061 | 43.87033 | 0.61206 | 13.59519 |
May | 508.00000 | 24.85793 | 51.51660 | -0.0563 | 6.57629 |
June | 496.00000 | 24.83222 | 56.15343 | -0.0178 | 6.48262 |
July | 497.00000 | 24.82159 | 60.31665 | 0.02242 | 6.52439 |
August | 514.00000 | 24.67879 | 61.65668 | -0.0041 | 6.26968 |
September | 485.00000 | 24.77370 | 59.13891 | 0.01470 | 6.39983 |
October | 502.00000 | 24.79072 | 49.17521 | 0.74388 | 17.61563 |
November | 489.00000 | 24.37744 | 42.13618 | 0.57689 | 13.24093 |
December | 497.00000 | 23.79155 | 37.55808 | 0.34651 | 9.16016 |
Annual Sum or Average | 5943.00000 | 24.39275 | 48.94322 | 0.27185 | 9.47893 |
Minimum of Months | 454.00000 | 23.25296 | 37.55808 | -0.0563 | 6.26968 |
Maximum of Months | 514.00000 | 24.85793 | 61.65668 | 0.74388 | 17.61563 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 23.05720 | 41.92847 | 0.11307 | 6.27972 |
February | 454.00000 | 23.56694 | 42.98513 | 0.26494 | 7.51998 |
March | 514.00000 | 24.06880 | 44.94993 | 0.44646 | 9.78292 |
April | 485.00000 | 24.46346 | 44.50430 | 0.60176 | 13.17870 |
May | 508.00000 | 24.58444 | 49.99931 | -0.0876 | 6.47661 |
June | 496.00000 | 24.55038 | 52.51840 | -0.0631 | 6.34965 |
July | 497.00000 | 24.66698 | 54.14906 | -0.0400 | 6.71465 |
August | 514.00000 | 24.54209 | 54.13115 | -0.0842 | 6.42858 |
September | 485.00000 | 24.59502 | 54.01791 | -0.0796 | 6.47555 |
October | 502.00000 | 24.49819 | 48.89762 | 0.62949 | 13.86268 |
November | 489.00000 | 24.15654 | 43.74639 | 0.45878 | 9.89315 |
December | 497.00000 | 23.49623 | 39.76399 | 0.22175 | 6.79151 |
Annual Sum or Average | 5943.00000 | 24.19100 | 47.67566 | 0.19711 | 8.30901 |
Minimum of Months | 454.00000 | 23.05720 | 39.76399 | -0.0876 | 6.27972 |
Maximum of Months | 514.00000 | 24.66698 | 54.14906 | 0.62949 | 13.86268 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 22.58210 | 43.07187 | -0.0203 | 6.16568 |
February | 454.00000 | 23.40686 | 43.27367 | 0.20978 | 6.88594 |
March | 514.00000 | 24.05782 | 45.21712 | 0.42720 | 9.21987 |
April | 485.00000 | 24.45011 | 45.53545 | 0.57544 | 12.40847 |
May | 508.00000 | 24.57066 | 51.73498 | -0.1249 | 6.47150 |
June | 496.00000 | 24.52315 | 54.86123 | -0.1097 | 6.33125 |
July | 497.00000 | 24.63895 | 56.86229 | -0.0763 | 6.71827 |
August | 514.00000 | 24.48914 | 57.11219 | -0.1380 | 6.50997 |
September | 485.00000 | 24.50677 | 56.95415 | -0.1618 | 6.72054 |
October | 502.00000 | 24.30993 | 50.22666 | 0.54146 | 11.47548 |
November | 489.00000 | 23.81508 | 44.61591 | 0.33816 | 7.87166 |
December | 497.00000 | 22.94461 | 41.04192 | 0.06610 | 6.08762 |
Annual Sum or Average | 5943.00000 | 24.02889 | 49.26046 | 0.12596 | 7.73791 |
Minimum of Months | 454.00000 | 22.58210 | 41.04192 | -0.1618 | 6.08762 |
Maximum of Months | 514.00000 | 24.63895 | 57.11219 | 0.57544 | 12.40847 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 427.00000 | 22.77754 | 42.15367 | 0.03827 | 6.19736 |
February | 385.00000 | 23.60141 | 41.98482 | 0.27108 | 7.68274 |
March | 433.00000 | 24.19640 | 43.87742 | 0.48039 | 10.59721 |
April | 410.00000 | 24.62393 | 44.27103 | 0.64640 | 14.65590 |
May | 430.00000 | 24.71235 | 51.08664 | -0.0362 | 6.81348 |
June | 418.00000 | 24.63235 | 54.50417 | -0.0529 | 6.51138 |
July | 422.00000 | 24.76474 | 56.68224 | -0.0237 | 7.08313 |
August | 433.00000 | 24.58882 | 56.98126 | -0.0981 | 6.67232 |
September | 410.00000 | 24.60952 | 56.81756 | -0.1100 | 6.75242 |
October | 427.00000 | 24.48320 | 49.19216 | 0.59807 | 13.30529 |
November | 417.00000 | 23.97395 | 43.30340 | 0.39023 | 8.98736 |
December | 422.00000 | 23.13210 | 39.96075 | 0.12171 | 6.39335 |
Annual Sum or Average | 5034.00000 | 24.17736 | 48.44613 | 0.18434 | 8.46781 |
Minimum of Months | 385.00000 | 22.77754 | 39.96075 | -0.1100 | 6.19736 |
Maximum of Months | 433.00000 | 24.76474 | 56.98126 | 0.64640 | 14.65590 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 23.42684 | 39.79761 | 0.22301 | 7.77732 |
February | 454.00000 | 23.93719 | 41.10041 | 0.38526 | 9.61210 |
March | 514.00000 | 24.23550 | 44.17713 | 0.52038 | 11.47958 |
April | 485.00000 | 24.51363 | 45.16135 | 0.62188 | 13.77899 |
May | 508.00000 | 24.57372 | 51.68037 | -0.1146 | 6.48127 |
June | 496.00000 | 24.51941 | 54.87401 | -0.1127 | 6.35002 |
July | 497.00000 | 24.63794 | 56.85008 | -0.0750 | 6.73353 |
August | 514.00000 | 24.50052 | 56.98928 | -0.1231 | 6.52715 |
September | 485.00000 | 24.54756 | 56.56369 | -0.1081 | 6.63673 |
October | 502.00000 | 24.52676 | 49.07015 | 0.66027 | 15.11282 |
November | 489.00000 | 24.28817 | 42.35386 | 0.53019 | 12.19601 |
December | 497.00000 | 23.78464 | 37.95032 | 0.31569 | 8.78122 |
Annual Sum or Average | 5943.00000 | 24.29298 | 48.10792 | 0.22488 | 9.27623 |
Minimum of Months | 454.00000 | 23.42684 | 37.95032 | -0.1231 | 6.35002 |
Maximum of Months | 514.00000 | 24.63794 | 56.98928 | 0.66027 | 15.11282 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 22.70309 | 42.40721 | 0.02991 | 6.53695 |
February | 454.00000 | 23.46862 | 42.82695 | 0.25029 | 7.74804 |
March | 514.00000 | 24.09128 | 44.90553 | 0.47238 | 10.43922 |
April | 485.00000 | 24.49532 | 45.33437 | 0.63500 | 14.23095 |
May | 508.00000 | 24.58896 | 51.65754 | -0.0616 | 6.66968 |
June | 496.00000 | 24.53957 | 54.79341 | -0.0540 | 6.47403 |
July | 497.00000 | 24.63911 | 56.84848 | -0.0516 | 6.85679 |
August | 514.00000 | 24.49101 | 57.14046 | -0.1134 | 6.53496 |
September | 485.00000 | 24.51860 | 56.87696 | -0.1206 | 6.65062 |
October | 502.00000 | 24.35283 | 50.01779 | 0.58453 | 12.85214 |
November | 489.00000 | 23.87628 | 44.16267 | 0.38405 | 8.98065 |
December | 497.00000 | 23.03236 | 40.40346 | 0.10929 | 6.58415 |
Annual Sum or Average | 5943.00000 | 24.07049 | 49.00122 | 0.17070 | 8.37527 |
Minimum of Months | 454.00000 | 22.70309 | 40.40346 | -0.1206 | 6.47403 |
Maximum of Months | 514.00000 | 24.63911 | 57.14046 | 0.63500 | 14.23095 |
Report: DXReportMonthly
For: PACU_VAV_BOT COOLING COIL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.214437E+11 | 0.554924E+10 | 371.49 | 0.189949E+11 | 0.244878E+10 | 0.00 | 0.92 | 12-JAN-15:00 | 0.00 | 01-JAN-00:10 | 37071.97 | 12-JAN-15:00 | 37071.97 | 12-JAN-15:00 | 6829.91 | 17-JAN-17:13 | 8654.71 | 12-JAN-15:00 | 0.00 |
February | 0.303701E+11 | 0.759207E+10 | 370.67 | 0.274589E+11 | 0.291112E+10 | 0.00 | 1.00 | 07-FEB-14:00 | 0.00 | 01-FEB-00:10 | 50052.01 | 22-FEB-16:10 | 50052.01 | 22-FEB-16:10 | 8416.44 | 25-FEB-17:00 | 12202.84 | 22-FEB-14:00 | 0.00 |
March | 0.548301E+11 | 0.140787E+11 | 453.56 | 0.510694E+11 | 0.376070E+10 | 0.00 | 1.00 | 01-MAR-13:30 | 0.00 | 01-MAR-00:10 | 73543.35 | 29-MAR-11:20 | 66353.39 | 28-MAR-16:00 | 19991.83 | 29-MAR-11:10 | 20735.59 | 28-MAR-15:50 | 0.00 |
April | 0.758726E+11 | 0.219292E+11 | 453.55 | 0.709172E+11 | 0.495546E+10 | 0.00 | 1.00 | 01-APR-15:20 | 0.00 | 01-APR-00:10 | 97749.32 | 27-APR-04:03 | 87603.46 | 28-APR-04:02 | 25184.38 | 18-APR-11:04 | 27956.35 | 18-APR-15:20 | 0.00 |
May | 0.109851E+12 | 0.336412E+11 | 514.17 | 0.919529E+11 | 0.178983E+11 | 0.00 | 1.00 | 01-MAY-04:03 | 0.00 | 01-MAY-00:33 | 130224.22 | 24-MAY-04:03 | 95224.13 | 04-MAY-04:02 | 59177.07 | 24-MAY-04:03 | 34943.90 | 01-MAY-15:20 | 0.00 |
June | 0.124963E+12 | 0.372728E+11 | 513.75 | 0.934786E+11 | 0.314842E+11 | 0.00 | 1.00 | 01-JUN-04:03 | 0.00 | 01-JUN-00:10 | 133930.22 | 27-JUN-04:02 | 97874.77 | 12-JUN-06:03 | 56853.06 | 28-JUN-12:02 | 36869.38 | 22-JUN-16:00 | 0.00 |
July | 0.136881E+12 | 0.371466E+11 | 523.77 | 0.866835E+11 | 0.501975E+11 | 0.00 | 1.00 | 01-JUL-04:02 | 0.00 | 01-JUL-00:05 | 136871.51 | 20-JUL-04:02 | 88460.46 | 05-JUL-06:03 | 65056.46 | 20-JUL-04:02 | 36430.65 | 10-JUL-12:02 | 0.00 |
August | 0.140138E+12 | 0.367565E+11 | 511.32 | 0.863534E+11 | 0.537846E+11 | 0.00 | 1.00 | 01-AUG-04:02 | 0.00 | 01-AUG-00:10 | 134051.79 | 11-AUG-04:03 | 87296.62 | 07-AUG-06:03 | 61785.84 | 27-AUG-14:52 | 35785.10 | 27-AUG-14:52 | 0.00 |
September | 0.113225E+12 | 0.294546E+11 | 466.22 | 0.753738E+11 | 0.378510E+11 | 0.00 | 1.00 | 01-SEP-04:02 | 0.00 | 01-SEP-00:10 | 132947.54 | 06-SEP-04:02 | 88372.63 | 26-SEP-04:02 | 57200.74 | 08-SEP-04:03 | 31751.58 | 02-SEP-04:03 | 0.00 |
October | 0.783232E+11 | 0.204745E+11 | 472.17 | 0.669623E+11 | 0.113608E+11 | 0.00 | 1.00 | 01-OCT-09:23 | 0.00 | 01-OCT-00:10 | 122168.65 | 04-OCT-04:02 | 85555.38 | 11-OCT-04:02 | 38075.38 | 04-OCT-04:02 | 28662.07 | 04-OCT-04:02 | 0.00 |
November | 0.490539E+11 | 0.122052E+11 | 424.69 | 0.455609E+11 | 0.349297E+10 | 0.00 | 1.00 | 01-NOV-06:02 | 0.00 | 01-NOV-00:10 | 63228.20 | 06-NOV-14:00 | 59014.84 | 13-NOV-14:00 | 11803.58 | 08-NOV-17:10 | 16355.69 | 06-NOV-14:00 | 0.00 |
December | 0.268716E+11 | 0.681697E+10 | 397.00 | 0.245897E+11 | 0.228188E+10 | 0.00 | 1.00 | 01-DEC-13:20 | 0.00 | 01-DEC-00:10 | 43051.65 | 01-DEC-14:00 | 43051.65 | 01-DEC-14:00 | 6788.18 | 29-DEC-18:07 | 9830.76 | 01-DEC-14:00 | 0.00 |
Annual Sum or Average | 0.961823E+12 | 0.262918E+12 | 5472.35 | 0.739396E+12 | 0.222427E+12 | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 0.214437E+11 | 0.554924E+10 | 370.67 | 0.189949E+11 | 0.228188E+10 | 0.00 | 0.92 | 0.00 | 37071.97 | 37071.97 | 6788.18 | 8654.71 | 0.00 | ||||||
Maximum of Months | 0.140138E+12 | 0.372728E+11 | 523.77 | 0.934786E+11 | 0.537846E+11 | 0.00 | 1.00 | 0.00 | 136871.51 | 97874.77 | 65056.46 | 36869.38 | 0.00 |
Report: DXReportMonthly
For: PACU_VAV_MID COOLING COIL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.148108E+11 | 0.392081E+10 | 347.36 | 0.123760E+11 | 0.243481E+10 | 0.00 | 0.83 | 12-JAN-15:10 | 0.00 | 01-JAN-00:10 | 29240.48 | 12-JAN-15:10 | 29240.48 | 12-JAN-15:10 | 6488.99 | 17-JAN-15:00 | 7020.37 | 12-JAN-15:10 | 0.00 |
February | 0.238994E+11 | 0.605458E+10 | 360.89 | 0.209076E+11 | 0.299176E+10 | 0.00 | 1.00 | 21-FEB-13:10 | 0.00 | 01-FEB-00:10 | 43629.08 | 22-FEB-15:30 | 43629.08 | 22-FEB-15:30 | 7946.45 | 25-FEB-17:00 | 10745.64 | 22-FEB-15:10 | 0.00 |
March | 0.476477E+11 | 0.122894E+11 | 449.75 | 0.441943E+11 | 0.345341E+10 | 0.00 | 1.00 | 01-MAR-14:40 | 0.00 | 01-MAR-00:10 | 63063.04 | 28-MAR-16:00 | 63063.04 | 28-MAR-16:00 | 10525.59 | 10-MAR-21:00 | 19644.05 | 28-MAR-16:00 | 0.00 |
April | 0.696989E+11 | 0.201013E+11 | 460.08 | 0.658359E+11 | 0.386302E+10 | 0.00 | 1.00 | 01-APR-12:40 | 0.00 | 01-APR-00:10 | 97424.45 | 27-APR-04:03 | 80410.95 | 17-APR-04:02 | 24859.90 | 27-APR-04:03 | 29545.69 | 16-APR-15:22 | 0.00 |
May | 0.100031E+12 | 0.304331E+11 | 523.23 | 0.847608E+11 | 0.152698E+11 | 0.00 | 1.00 | 01-MAY-04:03 | 0.00 | 01-MAY-00:23 | 122216.78 | 24-MAY-04:03 | 87879.69 | 30-MAY-06:03 | 57035.65 | 24-MAY-04:03 | 33671.94 | 01-MAY-15:10 | 0.00 |
June | 0.110733E+12 | 0.327481E+11 | 511.86 | 0.833339E+11 | 0.273993E+11 | 0.00 | 1.00 | 01-JUN-04:03 | 0.00 | 01-JUN-00:10 | 123168.01 | 27-JUN-04:02 | 92072.13 | 12-JUN-06:03 | 55883.07 | 27-JUN-04:02 | 38192.32 | 11-JUN-14:51 | 0.00 |
July | 0.118027E+12 | 0.317962E+11 | 508.13 | 0.738674E+11 | 0.441598E+11 | 0.00 | 1.00 | 01-JUL-04:02 | 0.00 | 01-JUL-00:05 | 125238.09 | 20-JUL-04:02 | 80673.20 | 05-JUL-04:33 | 64362.17 | 20-JUL-04:02 | 36816.34 | 02-JUL-16:12 | 0.00 |
August | 0.116274E+12 | 0.302459E+11 | 491.74 | 0.702188E+11 | 0.460555E+11 | 0.00 | 1.00 | 01-AUG-04:02 | 0.00 | 01-AUG-00:10 | 122711.50 | 19-AUG-05:03 | 77777.45 | 07-AUG-06:03 | 56842.51 | 11-AUG-05:03 | 34002.36 | 06-AUG-15:32 | 0.00 |
September | 0.926074E+11 | 0.239133E+11 | 448.33 | 0.604071E+11 | 0.322003E+11 | 0.00 | 1.00 | 01-SEP-04:02 | 0.00 | 01-SEP-00:10 | 121959.03 | 06-SEP-04:02 | 77660.19 | 25-SEP-04:02 | 56809.64 | 06-SEP-04:02 | 32291.39 | 24-SEP-16:32 | 0.00 |
October | 0.622642E+11 | 0.163792E+11 | 446.81 | 0.530437E+11 | 0.922049E+10 | 0.00 | 1.00 | 01-OCT-08:53 | 0.00 | 01-OCT-00:10 | 93532.43 | 04-OCT-05:03 | 72005.13 | 02-OCT-04:02 | 29830.59 | 04-OCT-05:03 | 23945.79 | 02-OCT-15:00 | 0.00 |
November | 0.372632E+11 | 0.942028E+10 | 407.58 | 0.338776E+11 | 0.338560E+10 | 0.00 | 1.00 | 01-NOV-10:30 | 0.00 | 01-NOV-00:10 | 53399.52 | 06-NOV-14:00 | 49117.38 | 13-NOV-15:10 | 8285.50 | 08-NOV-19:10 | 13802.89 | 06-NOV-14:00 | 0.00 |
December | 0.186372E+11 | 0.485609E+10 | 382.47 | 0.160896E+11 | 0.254764E+10 | 0.00 | 0.93 | 01-DEC-15:10 | 0.00 | 01-DEC-00:10 | 33785.65 | 01-DEC-15:10 | 33785.65 | 01-DEC-15:10 | 5663.77 | 29-DEC-18:00 | 7879.62 | 01-DEC-15:10 | 0.00 |
Annual Sum or Average | 0.811894E+12 | 0.222158E+12 | 5338.22 | 0.618913E+12 | 0.192982E+12 | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 0.148108E+11 | 0.392081E+10 | 347.36 | 0.123760E+11 | 0.243481E+10 | 0.00 | 0.83 | 0.00 | 29240.48 | 29240.48 | 5663.77 | 7020.37 | 0.00 | ||||||
Maximum of Months | 0.118027E+12 | 0.327481E+11 | 523.23 | 0.847608E+11 | 0.460555E+11 | 0.00 | 1.00 | 0.00 | 125238.09 | 92072.13 | 64362.17 | 38192.32 | 0.00 |
Report: DXReportMonthly
For: PACU_VAV_TOP COOLING COIL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.151230E+11 | 0.403703E+10 | 330.63 | 0.122352E+11 | 0.288782E+10 | 0.00 | 0.76 | 12-JAN-15:00 | 0.00 | 01-JAN-00:10 | 30782.03 | 12-JAN-15:00 | 30782.03 | 12-JAN-15:00 | 7021.92 | 17-JAN-15:00 | 7532.48 | 12-JAN-15:00 | 0.00 |
February | 0.245046E+11 | 0.627700E+10 | 350.45 | 0.209330E+11 | 0.357165E+10 | 0.00 | 1.00 | 20-FEB-15:43 | 0.00 | 01-FEB-00:10 | 50835.02 | 22-FEB-15:00 | 50835.02 | 22-FEB-15:00 | 8675.02 | 25-FEB-17:00 | 12589.26 | 22-FEB-15:00 | 0.00 |
March | 0.512685E+11 | 0.133733E+11 | 446.82 | 0.468860E+11 | 0.438257E+10 | 0.00 | 1.00 | 01-MAR-15:10 | 0.00 | 01-MAR-00:10 | 76817.55 | 28-MAR-16:00 | 76817.55 | 28-MAR-16:00 | 11924.19 | 10-MAR-20:30 | 23799.08 | 28-MAR-16:00 | 0.00 |
April | 0.780304E+11 | 0.227280E+11 | 457.99 | 0.737287E+11 | 0.430165E+10 | 0.00 | 1.00 | 01-APR-12:20 | 0.00 | 01-APR-00:10 | 113840.01 | 16-APR-16:02 | 102964.94 | 16-APR-15:22 | 20998.34 | 19-APR-05:03 | 37132.56 | 16-APR-15:22 | 0.00 |
May | 0.112533E+12 | 0.344861E+11 | 531.52 | 0.966106E+11 | 0.159222E+11 | 0.00 | 1.00 | 01-MAY-06:03 | 0.00 | 01-MAY-00:23 | 139829.20 | 24-MAY-04:03 | 109260.93 | 29-MAY-16:41 | 66863.87 | 24-MAY-04:03 | 40861.57 | 28-MAY-15:51 | 0.00 |
June | 0.123671E+12 | 0.368324E+11 | 523.71 | 0.953894E+11 | 0.282817E+11 | 0.00 | 1.00 | 01-JUN-04:03 | 0.00 | 01-JUN-00:10 | 144267.98 | 27-JUN-04:02 | 108622.64 | 11-JUN-15:02 | 63903.69 | 27-JUN-04:02 | 45568.14 | 11-JUN-15:02 | 0.00 |
July | 0.129330E+12 | 0.349628E+11 | 526.38 | 0.834788E+11 | 0.458517E+11 | 0.00 | 1.00 | 01-JUL-04:02 | 0.00 | 01-JUL-00:05 | 147019.23 | 26-JUL-04:03 | 101467.66 | 04-JUL-16:32 | 76729.33 | 26-JUL-04:03 | 43056.76 | 02-JUL-15:52 | 0.00 |
August | 0.124067E+12 | 0.323823E+11 | 498.93 | 0.773248E+11 | 0.467425E+11 | 0.00 | 1.00 | 01-AUG-04:02 | 0.00 | 01-AUG-00:10 | 143868.36 | 31-AUG-04:02 | 93719.57 | 06-AUG-15:22 | 70422.44 | 17-AUG-05:03 | 39743.17 | 06-AUG-15:22 | 0.00 |
September | 0.973066E+11 | 0.252908E+11 | 450.22 | 0.648619E+11 | 0.324447E+11 | 0.00 | 1.00 | 01-SEP-04:02 | 0.00 | 01-SEP-00:10 | 142359.15 | 01-SEP-04:02 | 91547.35 | 25-SEP-04:02 | 63837.55 | 11-SEP-04:02 | 34055.95 | 17-SEP-15:12 | 0.00 |
October | 0.653151E+11 | 0.173921E+11 | 439.64 | 0.557848E+11 | 0.953024E+10 | 0.00 | 1.00 | 01-OCT-11:02 | 0.00 | 01-OCT-00:10 | 88578.49 | 04-OCT-12:40 | 82562.64 | 01-OCT-15:02 | 19927.02 | 06-OCT-05:03 | 27705.82 | 02-OCT-14:50 | 0.00 |
November | 0.378157E+11 | 0.970441E+10 | 402.21 | 0.337373E+11 | 0.407842E+10 | 0.00 | 1.00 | 01-NOV-12:05 | 0.00 | 01-NOV-00:10 | 58822.91 | 09-NOV-13:30 | 56959.01 | 09-NOV-14:50 | 9545.22 | 08-NOV-18:40 | 15301.83 | 09-NOV-13:40 | 0.00 |
December | 0.181577E+11 | 0.479082E+10 | 362.14 | 0.149818E+11 | 0.317589E+10 | 0.00 | 0.87 | 01-DEC-14:50 | 0.00 | 01-DEC-00:10 | 36550.77 | 01-DEC-14:50 | 36550.77 | 01-DEC-14:50 | 6238.09 | 29-DEC-17:00 | 8661.92 | 01-DEC-14:50 | 0.00 |
Annual Sum or Average | 0.877123E+12 | 0.242257E+12 | 5320.65 | 0.675952E+12 | 0.201171E+12 | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 0.151230E+11 | 0.403703E+10 | 330.63 | 0.122352E+11 | 0.288782E+10 | 0.00 | 0.76 | 0.00 | 30782.03 | 30782.03 | 6238.09 | 7532.48 | 0.00 | ||||||
Maximum of Months | 0.129330E+12 | 0.368324E+11 | 531.52 | 0.966106E+11 | 0.467425E+11 | 0.00 | 1.00 | 0.00 | 147019.23 | 109260.93 | 76729.33 | 45568.14 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 311.07 | 0.00 | 311.07 | 219.31 | 1012.32 | 11.17 | 0.00 | 0.00 |
February | 368.88 | 0.00 | 368.88 | 383.31 | 803.45 | 0.00 | 0.00 | 0.00 |
March | 444.50 | 0.00 | 444.50 | 690.19 | 485.85 | 0.00 | 0.00 | 0.00 |
April | 482.32 | 1.64 | 480.69 | 1164.21 | 174.98 | 0.00 | 0.00 | 0.00 |
May | 534.38 | 15.00 | 519.38 | 1604.27 | 32.96 | 0.00 | 0.00 | 0.00 |
June | 553.17 | 20.49 | 532.68 | 1740.40 | 24.21 | 0.00 | 0.00 | 0.00 |
July | 545.55 | 8.64 | 536.91 | 1549.40 | 5.61 | 0.00 | 0.00 | 0.00 |
August | 500.83 | 1.56 | 499.27 | 1309.10 | 18.33 | 0.00 | 0.00 | 0.00 |
September | 446.25 | 0.03 | 446.22 | 1027.00 | 72.72 | 0.00 | 0.00 | 0.00 |
October | 386.60 | 0.00 | 386.60 | 756.05 | 380.14 | 0.00 | 0.00 | 0.00 |
November | 327.45 | 0.00 | 327.45 | 433.01 | 720.28 | 0.00 | 0.00 | 0.00 |
December | 303.46 | 0.00 | 303.46 | 240.71 | 990.80 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 434.03 | 3.96 | 430.07 | 929.07 | 391.70 | 11.17 | 0.00 | 0.00 |
Minimum of Months | 303.46 | 0.00 | 303.46 | 219.31 | 5.61 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 553.17 | 20.49 | 536.91 | 1740.40 | 1012.32 | 11.17 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 444.25 | 178.31 | 265.93 | 493.83 | 625.46 | 16.00 | 0.00 | 0.00 |
February | 539.71 | 222.82 | 316.89 | 720.20 | 505.97 | 0.00 | 0.00 | 0.00 |
March | 658.38 | 271.76 | 386.63 | 1073.50 | 312.13 | 0.00 | 0.00 | 0.00 |
April | 783.31 | 365.22 | 418.09 | 1580.56 | 117.80 | 0.00 | 0.00 | 0.00 |
May | 770.99 | 341.81 | 429.18 | 1790.18 | 21.60 | 0.00 | 0.00 | 0.00 |
June | 627.48 | 208.20 | 419.29 | 1613.48 | 16.12 | 0.00 | 0.00 | 0.00 |
July | 527.38 | 111.37 | 416.02 | 1322.30 | 3.32 | 0.00 | 0.00 | 0.00 |
August | 475.20 | 82.69 | 392.50 | 1120.51 | 12.37 | 0.00 | 0.00 | 0.00 |
September | 507.69 | 141.58 | 366.11 | 1052.25 | 48.66 | 0.00 | 0.00 | 0.00 |
October | 555.36 | 224.33 | 331.03 | 1024.23 | 248.67 | 0.00 | 0.00 | 0.00 |
November | 492.40 | 211.36 | 281.04 | 744.93 | 458.05 | 0.00 | 0.00 | 0.00 |
December | 429.35 | 170.11 | 259.24 | 510.99 | 624.80 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 567.47 | 210.47 | 357.00 | 1088.50 | 248.45 | 16.00 | 0.00 | 0.00 |
Minimum of Months | 429.35 | 82.69 | 259.24 | 493.83 | 3.32 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 783.31 | 365.22 | 429.18 | 1790.18 | 625.46 | 16.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 1414.74 | 859.63 | 555.11 | 1981.94 | 969.41 | 9.83 | 0.00 | 0.00 |
February | 1345.21 | 747.17 | 598.04 | 2031.17 | 797.72 | 0.00 | 0.00 | 0.00 |
March | 1150.19 | 508.03 | 642.16 | 2015.21 | 499.12 | 0.00 | 0.00 | 0.00 |
April | 807.90 | 228.01 | 579.89 | 1869.18 | 185.43 | 0.00 | 0.00 | 0.00 |
May | 580.99 | 43.01 | 537.98 | 1722.40 | 31.92 | 0.00 | 0.00 | 0.00 |
June | 531.45 | 9.07 | 522.38 | 1699.31 | 23.97 | 0.00 | 0.00 | 0.00 |
July | 554.36 | 7.62 | 546.73 | 1574.71 | 4.98 | 0.00 | 0.00 | 0.00 |
August | 588.05 | 31.41 | 556.65 | 1487.56 | 18.73 | 0.00 | 0.00 | 0.00 |
September | 788.33 | 204.61 | 583.72 | 1684.77 | 77.36 | 0.00 | 0.00 | 0.00 |
October | 1356.24 | 757.32 | 598.92 | 2512.95 | 397.15 | 0.00 | 0.00 | 0.00 |
November | 1694.02 | 1119.71 | 574.31 | 2763.41 | 730.93 | 0.00 | 0.00 | 0.00 |
December | 1511.87 | 947.38 | 564.49 | 2194.19 | 966.83 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1025.11 | 453.56 | 571.55 | 1960.36 | 390.14 | 9.83 | 0.00 | 0.00 |
Minimum of Months | 531.45 | 7.62 | 522.38 | 1487.56 | 4.98 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1694.02 | 1119.71 | 642.16 | 2763.41 | 969.41 | 9.83 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 434.63 | 169.14 | 265.49 | 528.82 | 672.56 | 17.33 | 0.00 | 0.00 |
February | 497.01 | 183.16 | 313.85 | 691.91 | 540.34 | 0.00 | 0.00 | 0.00 |
March | 644.49 | 257.63 | 386.87 | 1071.74 | 333.92 | 0.00 | 0.00 | 0.00 |
April | 783.37 | 367.37 | 416.00 | 1587.14 | 125.61 | 0.00 | 0.00 | 0.00 |
May | 741.78 | 314.65 | 427.13 | 1745.03 | 24.37 | 0.00 | 0.00 | 0.00 |
June | 696.73 | 270.63 | 426.10 | 1735.83 | 17.30 | 0.00 | 0.00 | 0.00 |
July | 517.01 | 100.56 | 416.45 | 1298.63 | 3.96 | 0.00 | 0.00 | 0.00 |
August | 474.82 | 84.39 | 390.43 | 1121.54 | 12.74 | 0.00 | 0.00 | 0.00 |
September | 521.95 | 153.23 | 368.72 | 1079.60 | 51.60 | 0.00 | 0.00 | 0.00 |
October | 543.27 | 216.33 | 326.94 | 1020.13 | 261.78 | 0.00 | 0.00 | 0.00 |
November | 491.48 | 209.46 | 282.01 | 782.62 | 487.83 | 0.00 | 0.00 | 0.00 |
December | 420.56 | 160.37 | 260.19 | 531.15 | 654.67 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 563.82 | 206.97 | 356.85 | 1100.70 | 264.34 | 17.33 | 0.00 | 0.00 |
Minimum of Months | 420.56 | 84.39 | 260.19 | 528.82 | 3.96 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 783.37 | 367.37 | 427.13 | 1745.03 | 672.56 | 17.33 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 103.69 | 0.00 | 103.69 | 64.29 | 382.48 | 9.17 | 0.00 | 0.00 |
February | 122.95 | 0.00 | 122.95 | 125.37 | 287.79 | 0.00 | 0.00 | 0.00 |
March | 148.16 | 0.00 | 148.16 | 235.58 | 162.78 | 0.00 | 0.00 | 0.00 |
April | 160.77 | 0.55 | 160.22 | 398.98 | 53.34 | 0.00 | 0.00 | 0.00 |
May | 178.12 | 5.00 | 173.12 | 544.89 | 8.82 | 0.00 | 0.00 | 0.00 |
June | 184.38 | 6.83 | 177.55 | 586.39 | 7.41 | 0.00 | 0.00 | 0.00 |
July | 181.84 | 2.88 | 178.96 | 517.90 | 2.28 | 0.00 | 0.00 | 0.00 |
August | 166.94 | 0.52 | 166.41 | 434.25 | 7.80 | 0.00 | 0.00 | 0.00 |
September | 148.74 | 0.01 | 148.73 | 338.97 | 29.69 | 0.00 | 0.00 | 0.00 |
October | 128.86 | 0.00 | 128.86 | 249.25 | 138.78 | 0.00 | 0.00 | 0.00 |
November | 109.15 | 0.00 | 109.15 | 137.17 | 268.97 | 0.00 | 0.00 | 0.00 |
December | 101.15 | 0.00 | 101.15 | 68.59 | 378.68 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 144.67 | 1.32 | 143.35 | 309.35 | 143.48 | 9.17 | 0.00 | 0.00 |
Minimum of Months | 101.15 | 0.00 | 101.15 | 64.29 | 2.28 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 184.38 | 6.83 | 178.96 | 586.39 | 382.48 | 9.17 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 103.69 | 0.00 | 103.69 | 64.29 | 382.50 | 9.17 | 0.00 | 0.00 |
February | 122.96 | 0.00 | 122.96 | 125.38 | 287.81 | 0.00 | 0.00 | 0.00 |
March | 148.17 | 0.00 | 148.17 | 235.59 | 162.79 | 0.00 | 0.00 | 0.00 |
April | 160.78 | 0.55 | 160.23 | 399.01 | 53.35 | 0.00 | 0.00 | 0.00 |
May | 178.13 | 5.00 | 173.13 | 544.93 | 8.83 | 0.00 | 0.00 | 0.00 |
June | 184.39 | 6.83 | 177.56 | 586.43 | 7.41 | 0.00 | 0.00 | 0.00 |
July | 181.85 | 2.88 | 178.97 | 517.93 | 2.28 | 0.00 | 0.00 | 0.00 |
August | 166.95 | 0.52 | 166.43 | 434.28 | 7.80 | 0.00 | 0.00 | 0.00 |
September | 148.75 | 0.01 | 148.74 | 338.99 | 29.69 | 0.00 | 0.00 | 0.00 |
October | 128.87 | 0.00 | 128.87 | 249.27 | 138.79 | 0.00 | 0.00 | 0.00 |
November | 109.15 | 0.00 | 109.15 | 137.18 | 268.98 | 0.00 | 0.00 | 0.00 |
December | 101.15 | 0.00 | 101.15 | 68.60 | 378.70 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 144.68 | 1.32 | 143.36 | 309.37 | 143.49 | 9.17 | 0.00 | 0.00 |
Minimum of Months | 101.15 | 0.00 | 101.15 | 64.29 | 2.28 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 184.39 | 6.83 | 178.97 | 586.43 | 382.50 | 9.17 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 103.69 | 0.00 | 103.69 | 64.29 | 382.50 | 9.17 | 0.00 | 0.00 |
February | 122.96 | 0.00 | 122.96 | 125.38 | 287.81 | 0.00 | 0.00 | 0.00 |
March | 148.17 | 0.00 | 148.17 | 235.59 | 162.79 | 0.00 | 0.00 | 0.00 |
April | 160.78 | 0.55 | 160.23 | 399.01 | 53.35 | 0.00 | 0.00 | 0.00 |
May | 178.13 | 5.00 | 173.13 | 544.93 | 8.83 | 0.00 | 0.00 | 0.00 |
June | 184.39 | 6.83 | 177.56 | 586.43 | 7.41 | 0.00 | 0.00 | 0.00 |
July | 181.85 | 2.88 | 178.97 | 517.93 | 2.28 | 0.00 | 0.00 | 0.00 |
August | 166.95 | 0.52 | 166.43 | 434.28 | 7.80 | 0.00 | 0.00 | 0.00 |
September | 148.75 | 0.01 | 148.74 | 338.99 | 29.69 | 0.00 | 0.00 | 0.00 |
October | 128.87 | 0.00 | 128.87 | 249.27 | 138.79 | 0.00 | 0.00 | 0.00 |
November | 109.15 | 0.00 | 109.15 | 137.18 | 268.98 | 0.00 | 0.00 | 0.00 |
December | 101.15 | 0.00 | 101.15 | 68.60 | 378.70 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 144.68 | 1.32 | 143.36 | 309.37 | 143.49 | 9.17 | 0.00 | 0.00 |
Minimum of Months | 101.15 | 0.00 | 101.15 | 64.29 | 2.28 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 184.39 | 6.83 | 178.97 | 586.43 | 382.50 | 9.17 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 427.35 | 171.53 | 255.82 | 447.48 | 687.93 | 18.67 | 0.00 | 0.00 |
February | 519.17 | 214.34 | 304.84 | 685.04 | 530.27 | 0.00 | 0.00 | 0.00 |
March | 633.34 | 261.42 | 371.92 | 1043.34 | 308.99 | 0.00 | 0.00 | 0.00 |
April | 753.51 | 351.32 | 402.19 | 1540.40 | 109.88 | 0.00 | 0.00 | 0.00 |
May | 741.66 | 328.81 | 412.85 | 1738.37 | 19.12 | 0.00 | 0.00 | 0.00 |
June | 603.61 | 200.28 | 403.34 | 1562.30 | 15.23 | 0.00 | 0.00 | 0.00 |
July | 507.32 | 107.13 | 400.19 | 1271.79 | 4.27 | 0.00 | 0.00 | 0.00 |
August | 457.12 | 79.55 | 377.57 | 1072.96 | 15.90 | 0.00 | 0.00 | 0.00 |
September | 488.38 | 136.20 | 352.18 | 1006.42 | 60.19 | 0.00 | 0.00 | 0.00 |
October | 534.23 | 215.79 | 318.44 | 980.16 | 266.92 | 0.00 | 0.00 | 0.00 |
November | 473.67 | 203.32 | 270.35 | 700.30 | 496.55 | 0.00 | 0.00 | 0.00 |
December | 413.02 | 163.64 | 249.38 | 461.14 | 690.34 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 545.88 | 202.46 | 343.42 | 1043.66 | 266.03 | 18.67 | 0.00 | 0.00 |
Minimum of Months | 413.02 | 79.55 | 249.38 | 447.48 | 4.27 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 753.51 | 351.32 | 412.85 | 1738.37 | 690.34 | 18.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 16.90 | 6.78 | 10.11 | 17.69 | 27.20 | 18.67 | 0.00 | 0.00 |
February | 20.53 | 8.47 | 12.05 | 27.09 | 20.97 | 0.00 | 0.00 | 0.00 |
March | 25.04 | 10.34 | 14.71 | 41.25 | 12.22 | 0.00 | 0.00 | 0.00 |
April | 29.79 | 13.89 | 15.90 | 60.91 | 4.34 | 0.00 | 0.00 | 0.00 |
May | 29.32 | 13.00 | 16.32 | 68.73 | 0.76 | 0.00 | 0.00 | 0.00 |
June | 23.87 | 7.92 | 15.95 | 61.77 | 0.60 | 0.00 | 0.00 | 0.00 |
July | 20.06 | 4.24 | 15.82 | 50.29 | 0.17 | 0.00 | 0.00 | 0.00 |
August | 18.07 | 3.15 | 14.93 | 42.42 | 0.63 | 0.00 | 0.00 | 0.00 |
September | 19.31 | 5.39 | 13.92 | 39.79 | 2.38 | 0.00 | 0.00 | 0.00 |
October | 21.12 | 8.53 | 12.59 | 38.75 | 10.55 | 0.00 | 0.00 | 0.00 |
November | 18.73 | 8.04 | 10.69 | 27.69 | 19.63 | 0.00 | 0.00 | 0.00 |
December | 16.33 | 6.47 | 9.86 | 18.23 | 27.30 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 21.58 | 8.01 | 13.58 | 41.27 | 10.52 | 18.67 | 0.00 | 0.00 |
Minimum of Months | 16.33 | 3.15 | 9.86 | 17.69 | 0.17 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 29.79 | 13.89 | 16.32 | 68.73 | 27.30 | 18.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 471.59 | 286.55 | 185.04 | 656.48 | 368.38 | 3.83 | 0.00 | 0.00 |
February | 448.42 | 249.06 | 199.35 | 678.84 | 291.08 | 0.00 | 0.00 | 0.00 |
March | 383.41 | 169.35 | 214.06 | 678.28 | 172.66 | 0.00 | 0.00 | 0.00 |
April | 269.31 | 76.01 | 193.30 | 629.53 | 59.74 | 0.00 | 0.00 | 0.00 |
May | 193.67 | 14.34 | 179.33 | 575.66 | 9.33 | 0.00 | 0.00 | 0.00 |
June | 177.16 | 3.02 | 174.13 | 564.32 | 7.56 | 0.00 | 0.00 | 0.00 |
July | 184.79 | 2.54 | 182.25 | 521.21 | 2.23 | 0.00 | 0.00 | 0.00 |
August | 196.02 | 10.47 | 185.55 | 489.89 | 8.32 | 0.00 | 0.00 | 0.00 |
September | 262.79 | 68.21 | 194.58 | 555.70 | 33.90 | 0.00 | 0.00 | 0.00 |
October | 452.09 | 252.45 | 199.65 | 832.85 | 151.43 | 0.00 | 0.00 | 0.00 |
November | 564.69 | 373.25 | 191.44 | 917.81 | 278.33 | 0.00 | 0.00 | 0.00 |
December | 503.97 | 315.80 | 188.17 | 723.36 | 369.49 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 341.71 | 151.19 | 190.52 | 651.61 | 145.41 | 3.83 | 0.00 | 0.00 |
Minimum of Months | 177.16 | 2.54 | 174.13 | 489.89 | 2.23 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 564.69 | 373.25 | 214.06 | 917.81 | 369.49 | 3.83 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 471.59 | 286.55 | 185.04 | 656.48 | 368.38 | 3.83 | 0.00 | 0.00 |
February | 448.42 | 249.06 | 199.35 | 678.84 | 291.08 | 0.00 | 0.00 | 0.00 |
March | 383.41 | 169.35 | 214.06 | 678.28 | 172.66 | 0.00 | 0.00 | 0.00 |
April | 269.31 | 76.01 | 193.30 | 629.53 | 59.74 | 0.00 | 0.00 | 0.00 |
May | 193.67 | 14.34 | 179.33 | 575.66 | 9.33 | 0.00 | 0.00 | 0.00 |
June | 177.16 | 3.02 | 174.13 | 564.32 | 7.56 | 0.00 | 0.00 | 0.00 |
July | 184.79 | 2.54 | 182.25 | 521.21 | 2.23 | 0.00 | 0.00 | 0.00 |
August | 196.02 | 10.47 | 185.55 | 489.89 | 8.32 | 0.00 | 0.00 | 0.00 |
September | 262.79 | 68.21 | 194.58 | 555.70 | 33.90 | 0.00 | 0.00 | 0.00 |
October | 452.09 | 252.45 | 199.65 | 832.85 | 151.43 | 0.00 | 0.00 | 0.00 |
November | 564.69 | 373.25 | 191.44 | 917.81 | 278.33 | 0.00 | 0.00 | 0.00 |
December | 503.97 | 315.80 | 188.17 | 723.36 | 369.49 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 341.71 | 151.19 | 190.52 | 651.61 | 145.41 | 3.83 | 0.00 | 0.00 |
Minimum of Months | 177.16 | 2.54 | 174.13 | 489.89 | 2.23 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 564.69 | 373.25 | 214.06 | 917.81 | 369.49 | 3.83 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 471.56 | 286.53 | 185.03 | 656.44 | 368.36 | 3.83 | 0.00 | 0.00 |
February | 448.39 | 249.05 | 199.34 | 678.80 | 291.06 | 0.00 | 0.00 | 0.00 |
March | 383.38 | 169.34 | 214.05 | 678.24 | 172.65 | 0.00 | 0.00 | 0.00 |
April | 269.29 | 76.00 | 193.29 | 629.49 | 59.73 | 0.00 | 0.00 | 0.00 |
May | 193.66 | 14.34 | 179.32 | 575.62 | 9.33 | 0.00 | 0.00 | 0.00 |
June | 177.14 | 3.02 | 174.12 | 564.28 | 7.56 | 0.00 | 0.00 | 0.00 |
July | 184.78 | 2.54 | 182.24 | 521.18 | 2.23 | 0.00 | 0.00 | 0.00 |
August | 196.01 | 10.47 | 185.54 | 489.86 | 8.32 | 0.00 | 0.00 | 0.00 |
September | 262.77 | 68.20 | 194.57 | 555.67 | 33.90 | 0.00 | 0.00 | 0.00 |
October | 452.07 | 252.43 | 199.63 | 832.80 | 151.42 | 0.00 | 0.00 | 0.00 |
November | 564.65 | 373.22 | 191.43 | 917.76 | 278.31 | 0.00 | 0.00 | 0.00 |
December | 503.94 | 315.78 | 188.16 | 723.32 | 369.47 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 341.69 | 151.18 | 190.51 | 651.57 | 145.40 | 3.83 | 0.00 | 0.00 |
Minimum of Months | 177.14 | 2.54 | 174.12 | 489.86 | 2.23 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 564.65 | 373.22 | 214.05 | 917.76 | 369.47 | 3.83 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 418.09 | 162.71 | 255.39 | 492.06 | 741.89 | 19.67 | 0.00 | 0.00 |
February | 478.10 | 176.19 | 301.91 | 661.43 | 569.21 | 0.00 | 0.00 | 0.00 |
March | 619.97 | 247.82 | 372.15 | 1041.96 | 332.80 | 0.00 | 0.00 | 0.00 |
April | 753.57 | 353.40 | 400.18 | 1545.29 | 118.68 | 0.00 | 0.00 | 0.00 |
May | 713.56 | 302.68 | 410.89 | 1691.24 | 22.27 | 0.00 | 0.00 | 0.00 |
June | 670.23 | 260.33 | 409.89 | 1676.55 | 16.99 | 0.00 | 0.00 | 0.00 |
July | 497.34 | 96.73 | 400.61 | 1248.29 | 4.94 | 0.00 | 0.00 | 0.00 |
August | 456.76 | 81.18 | 375.58 | 1072.59 | 16.37 | 0.00 | 0.00 | 0.00 |
September | 502.10 | 147.40 | 354.70 | 1032.35 | 64.41 | 0.00 | 0.00 | 0.00 |
October | 522.60 | 208.10 | 314.51 | 976.15 | 282.87 | 0.00 | 0.00 | 0.00 |
November | 472.78 | 201.50 | 271.29 | 739.44 | 533.73 | 0.00 | 0.00 | 0.00 |
December | 404.56 | 154.27 | 250.29 | 487.35 | 729.27 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 542.38 | 199.10 | 343.28 | 1056.51 | 284.92 | 19.67 | 0.00 | 0.00 |
Minimum of Months | 404.56 | 81.18 | 250.29 | 487.35 | 4.94 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 753.57 | 353.40 | 410.89 | 1691.24 | 741.89 | 19.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 16.53 | 6.43 | 10.10 | 19.46 | 29.33 | 19.67 | 0.00 | 0.00 |
February | 18.90 | 6.97 | 11.94 | 26.15 | 22.51 | 0.00 | 0.00 | 0.00 |
March | 24.51 | 9.80 | 14.71 | 41.20 | 13.16 | 0.00 | 0.00 | 0.00 |
April | 29.80 | 13.97 | 15.82 | 61.10 | 4.69 | 0.00 | 0.00 | 0.00 |
May | 28.21 | 11.97 | 16.25 | 66.87 | 0.88 | 0.00 | 0.00 | 0.00 |
June | 26.50 | 10.29 | 16.21 | 66.29 | 0.67 | 0.00 | 0.00 | 0.00 |
July | 19.66 | 3.82 | 15.84 | 49.36 | 0.20 | 0.00 | 0.00 | 0.00 |
August | 18.06 | 3.21 | 14.85 | 42.41 | 0.65 | 0.00 | 0.00 | 0.00 |
September | 19.85 | 5.83 | 14.02 | 40.82 | 2.55 | 0.00 | 0.00 | 0.00 |
October | 20.66 | 8.23 | 12.44 | 38.60 | 11.18 | 0.00 | 0.00 | 0.00 |
November | 18.69 | 7.97 | 10.73 | 29.24 | 21.10 | 0.00 | 0.00 | 0.00 |
December | 16.00 | 6.10 | 9.90 | 19.27 | 28.83 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 21.44 | 7.87 | 13.57 | 41.77 | 11.27 | 19.67 | 0.00 | 0.00 |
Minimum of Months | 16.00 | 3.21 | 9.90 | 19.27 | 0.20 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 29.80 | 13.97 | 16.25 | 66.87 | 29.33 | 19.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 311.07 | 0.00 | 311.07 | 194.47 | 1121.09 | 0.67 | 0.00 | 0.00 |
February | 368.88 | 0.00 | 368.88 | 365.79 | 875.60 | 0.00 | 0.00 | 0.00 |
March | 444.50 | 0.00 | 444.50 | 688.32 | 517.10 | 0.00 | 0.00 | 0.00 |
April | 482.32 | 1.64 | 480.69 | 1175.43 | 181.06 | 0.00 | 0.00 | 0.00 |
May | 534.38 | 15.00 | 519.38 | 1620.65 | 32.60 | 0.00 | 0.00 | 0.00 |
June | 553.17 | 20.49 | 532.68 | 1758.20 | 23.87 | 0.00 | 0.00 | 0.00 |
July | 545.55 | 8.64 | 536.91 | 1565.99 | 5.55 | 0.00 | 0.00 | 0.00 |
August | 500.83 | 1.56 | 499.27 | 1322.84 | 18.46 | 0.00 | 0.00 | 0.00 |
September | 446.25 | 0.03 | 446.22 | 1034.44 | 76.07 | 0.00 | 0.00 | 0.00 |
October | 386.60 | 0.00 | 386.60 | 757.43 | 402.35 | 0.00 | 0.00 | 0.00 |
November | 327.45 | 0.00 | 327.45 | 418.78 | 782.11 | 0.00 | 0.00 | 0.00 |
December | 303.46 | 0.00 | 303.46 | 214.14 | 1093.90 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 434.03 | 3.96 | 430.07 | 929.11 | 425.57 | 0.67 | 0.00 | 0.00 |
Minimum of Months | 303.46 | 0.00 | 303.46 | 194.47 | 5.55 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 553.17 | 20.49 | 536.91 | 1758.20 | 1121.09 | 0.67 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_2_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 444.25 | 178.31 | 265.93 | 470.39 | 685.64 | 15.00 | 0.00 | 0.00 |
February | 539.71 | 222.82 | 316.89 | 706.61 | 544.51 | 0.00 | 0.00 | 0.00 |
March | 658.38 | 271.76 | 386.63 | 1072.58 | 328.49 | 0.00 | 0.00 | 0.00 |
April | 783.31 | 365.22 | 418.09 | 1589.85 | 121.03 | 0.00 | 0.00 | 0.00 |
May | 770.99 | 341.81 | 429.18 | 1802.84 | 21.34 | 0.00 | 0.00 | 0.00 |
June | 627.48 | 208.20 | 419.29 | 1626.40 | 15.84 | 0.00 | 0.00 | 0.00 |
July | 527.38 | 111.37 | 416.02 | 1333.75 | 3.31 | 0.00 | 0.00 | 0.00 |
August | 475.20 | 82.69 | 392.50 | 1130.13 | 12.38 | 0.00 | 0.00 | 0.00 |
September | 507.69 | 141.58 | 366.11 | 1058.07 | 50.62 | 0.00 | 0.00 | 0.00 |
October | 555.36 | 224.33 | 331.03 | 1025.43 | 261.03 | 0.00 | 0.00 | 0.00 |
November | 492.40 | 211.36 | 281.04 | 734.02 | 491.13 | 0.00 | 0.00 | 0.00 |
December | 429.35 | 170.11 | 259.24 | 488.23 | 680.93 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 567.47 | 210.47 | 357.00 | 1087.83 | 266.83 | 15.00 | 0.00 | 0.00 |
Minimum of Months | 429.35 | 82.69 | 259.24 | 470.39 | 3.31 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 783.31 | 365.22 | 429.18 | 1802.84 | 685.64 | 15.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 1414.74 | 859.63 | 555.11 | 1955.48 | 1059.45 | 1.83 | 0.00 | 0.00 |
February | 1345.21 | 747.17 | 598.04 | 2017.09 | 858.79 | 0.00 | 0.00 | 0.00 |
March | 1150.19 | 508.03 | 642.16 | 2016.45 | 526.85 | 0.00 | 0.00 | 0.00 |
April | 807.90 | 228.01 | 579.89 | 1882.28 | 191.53 | 0.00 | 0.00 | 0.00 |
May | 580.99 | 43.01 | 537.98 | 1738.88 | 31.73 | 0.00 | 0.00 | 0.00 |
June | 531.45 | 9.07 | 522.38 | 1716.95 | 23.59 | 0.00 | 0.00 | 0.00 |
July | 554.36 | 7.62 | 546.73 | 1591.00 | 5.00 | 0.00 | 0.00 | 0.00 |
August | 588.05 | 31.41 | 556.65 | 1501.51 | 18.84 | 0.00 | 0.00 | 0.00 |
September | 788.33 | 204.61 | 583.72 | 1694.09 | 80.51 | 0.00 | 0.00 | 0.00 |
October | 1356.24 | 757.32 | 598.92 | 2516.31 | 416.83 | 0.00 | 0.00 | 0.00 |
November | 1694.02 | 1119.71 | 574.31 | 2754.24 | 781.87 | 0.00 | 0.00 | 0.00 |
December | 1511.87 | 947.38 | 564.49 | 2167.79 | 1049.52 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1025.11 | 453.56 | 571.55 | 1961.68 | 418.43 | 1.83 | 0.00 | 0.00 |
Minimum of Months | 531.45 | 7.62 | 522.38 | 1501.51 | 5.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1694.02 | 1119.71 | 642.16 | 2754.24 | 1059.45 | 1.83 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_4_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 434.63 | 169.14 | 265.49 | 513.23 | 740.74 | 14.17 | 0.00 | 0.00 |
February | 497.01 | 183.16 | 313.85 | 681.12 | 586.69 | 0.00 | 0.00 | 0.00 |
March | 644.49 | 257.63 | 386.87 | 1071.02 | 354.46 | 0.00 | 0.00 | 0.00 |
April | 783.37 | 367.37 | 416.00 | 1595.31 | 129.85 | 0.00 | 0.00 | 0.00 |
May | 741.78 | 314.65 | 427.13 | 1755.77 | 24.36 | 0.00 | 0.00 | 0.00 |
June | 696.73 | 270.63 | 426.10 | 1747.25 | 17.29 | 0.00 | 0.00 | 0.00 |
July | 517.01 | 100.56 | 416.45 | 1308.63 | 3.89 | 0.00 | 0.00 | 0.00 |
August | 474.82 | 84.39 | 390.43 | 1130.23 | 12.83 | 0.00 | 0.00 | 0.00 |
September | 521.95 | 153.23 | 368.72 | 1084.60 | 54.02 | 0.00 | 0.00 | 0.00 |
October | 543.27 | 216.33 | 326.94 | 1020.94 | 276.56 | 0.00 | 0.00 | 0.00 |
November | 491.48 | 209.46 | 282.01 | 773.63 | 527.77 | 0.00 | 0.00 | 0.00 |
December | 420.56 | 160.37 | 260.19 | 513.87 | 719.23 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 563.82 | 206.97 | 356.85 | 1100.87 | 286.00 | 14.17 | 0.00 | 0.00 |
Minimum of Months | 420.56 | 84.39 | 260.19 | 513.23 | 3.89 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 783.37 | 367.37 | 427.13 | 1755.77 | 740.74 | 14.17 | 0.00 | 0.00 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.833180E+09 | 0.00 | 0.833180E+09 | 0.587398E+09 | 0.271140E+10 |
February | 0.892396E+09 | 0.00 | 0.892396E+09 | 0.927293E+09 | 0.194371E+10 |
March | 0.119056E+10 | 0.00 | 0.119056E+10 | 0.184859E+10 | 0.130129E+10 |
April | 0.125018E+10 | 4239771.25 | 0.124594E+10 | 0.301762E+10 | 0.453540E+09 |
May | 0.143128E+10 | 40164306.61 | 0.139111E+10 | 0.429689E+10 | 88270215.15 |
June | 0.143381E+10 | 53108473.11 | 0.138070E+10 | 0.451111E+10 | 62759231.66 |
July | 0.146120E+10 | 23138931.59 | 0.143806E+10 | 0.414990E+10 | 15025873.94 |
August | 0.134142E+10 | 4180606.92 | 0.133724E+10 | 0.350629E+10 | 49095283.03 |
September | 0.115669E+10 | 81220.16 | 0.115661E+10 | 0.266199E+10 | 0.188495E+09 |
October | 0.103547E+10 | 0.00 | 0.103547E+10 | 0.202501E+10 | 0.101818E+10 |
November | 0.848759E+09 | 0.00 | 0.848759E+09 | 0.112237E+10 | 0.186698E+10 |
December | 0.812782E+09 | 0.00 | 0.812782E+09 | 0.644725E+09 | 0.265376E+10 |
Annual Sum or Average | 0.136877E+11 | 0.124913E+09 | 0.135628E+11 | 0.292992E+11 | 0.123525E+11 |
Minimum of Months | 0.812782E+09 | 0.00 | 0.812782E+09 | 0.587398E+09 | 15025873.94 |
Maximum of Months | 0.146120E+10 | 53108473.11 | 0.143806E+10 | 0.451111E+10 | 0.271140E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.118988E+10 | 0.477599E+09 | 0.712278E+09 | 0.132267E+10 | 0.167523E+10 |
February | 0.130566E+10 | 0.539035E+09 | 0.766623E+09 | 0.174230E+10 | 0.122404E+10 |
March | 0.176342E+10 | 0.727875E+09 | 0.103554E+10 | 0.287526E+10 | 0.836019E+09 |
April | 0.203033E+10 | 0.946642E+09 | 0.108369E+10 | 0.409680E+10 | 0.305335E+09 |
May | 0.206502E+10 | 0.915514E+09 | 0.114950E+10 | 0.479482E+10 | 57848383.12 |
June | 0.162644E+10 | 0.539649E+09 | 0.108679E+10 | 0.418215E+10 | 41793993.27 |
July | 0.141255E+10 | 0.298291E+09 | 0.111426E+10 | 0.354164E+10 | 8905204.90 |
August | 0.127276E+10 | 0.221490E+09 | 0.105127E+10 | 0.300116E+10 | 33134535.49 |
September | 0.131594E+10 | 0.366981E+09 | 0.948956E+09 | 0.272743E+10 | 0.126116E+09 |
October | 0.148746E+10 | 0.600835E+09 | 0.886628E+09 | 0.274329E+10 | 0.666035E+09 |
November | 0.127631E+10 | 0.547848E+09 | 0.728460E+09 | 0.193086E+10 | 0.118728E+10 |
December | 0.114998E+10 | 0.455629E+09 | 0.694355E+09 | 0.136865E+10 | 0.167346E+10 |
Annual Sum or Average | 0.178957E+11 | 0.663739E+10 | 0.112584E+11 | 0.343270E+11 | 0.783520E+10 |
Minimum of Months | 0.114998E+10 | 0.221490E+09 | 0.694355E+09 | 0.132267E+10 | 8905204.90 |
Maximum of Months | 0.206502E+10 | 0.946642E+09 | 0.114950E+10 | 0.479482E+10 | 0.167523E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.378924E+10 | 0.230243E+10 | 0.148680E+10 | 0.530844E+10 | 0.259648E+10 |
February | 0.325433E+10 | 0.180755E+10 | 0.144679E+10 | 0.491381E+10 | 0.192985E+10 |
March | 0.308067E+10 | 0.136070E+10 | 0.171997E+10 | 0.539753E+10 | 0.133685E+10 |
April | 0.209407E+10 | 0.591009E+09 | 0.150306E+10 | 0.484490E+10 | 0.480640E+09 |
May | 0.155611E+10 | 0.115194E+09 | 0.144092E+10 | 0.461327E+10 | 85489449.41 |
June | 0.137753E+10 | 23506957.74 | 0.135402E+10 | 0.440462E+10 | 62132777.19 |
July | 0.148479E+10 | 20421907.57 | 0.146436E+10 | 0.421770E+10 | 13349956.20 |
August | 0.157504E+10 | 84118756.83 | 0.149092E+10 | 0.398429E+10 | 50163291.91 |
September | 0.204336E+10 | 0.530356E+09 | 0.151300E+10 | 0.436692E+10 | 0.200520E+09 |
October | 0.363256E+10 | 0.202840E+10 | 0.160416E+10 | 0.673069E+10 | 0.106372E+10 |
November | 0.439089E+10 | 0.290228E+10 | 0.148861E+10 | 0.716275E+10 | 0.189457E+10 |
December | 0.404938E+10 | 0.253745E+10 | 0.151193E+10 | 0.587691E+10 | 0.258957E+10 |
Annual Sum or Average | 0.323280E+11 | 0.143034E+11 | 0.180245E+11 | 0.618218E+11 | 0.123033E+11 |
Minimum of Months | 0.137753E+10 | 20421907.57 | 0.135402E+10 | 0.398429E+10 | 13349956.20 |
Maximum of Months | 0.439089E+10 | 0.290228E+10 | 0.171997E+10 | 0.716275E+10 | 0.259648E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.116411E+10 | 0.453025E+09 | 0.711081E+09 | 0.141638E+10 | 0.180137E+10 |
February | 0.120236E+10 | 0.443102E+09 | 0.759260E+09 | 0.167388E+10 | 0.130718E+10 |
March | 0.172621E+10 | 0.690025E+09 | 0.103618E+10 | 0.287054E+10 | 0.894377E+09 |
April | 0.203051E+10 | 0.952228E+09 | 0.107828E+10 | 0.411387E+10 | 0.325573E+09 |
May | 0.198679E+10 | 0.842754E+09 | 0.114404E+10 | 0.467389E+10 | 65279390.31 |
June | 0.180593E+10 | 0.701469E+09 | 0.110446E+10 | 0.449928E+10 | 44834772.81 |
July | 0.138476E+10 | 0.269336E+09 | 0.111543E+10 | 0.347825E+10 | 10604586.38 |
August | 0.127176E+10 | 0.226030E+09 | 0.104573E+10 | 0.300392E+10 | 34135640.96 |
September | 0.135290E+10 | 0.397172E+09 | 0.955727E+09 | 0.279831E+10 | 0.133747E+09 |
October | 0.145510E+10 | 0.579416E+09 | 0.875682E+09 | 0.273231E+10 | 0.701142E+09 |
November | 0.127391E+10 | 0.542933E+09 | 0.730980E+09 | 0.202854E+10 | 0.126445E+10 |
December | 0.112643E+10 | 0.429533E+09 | 0.696899E+09 | 0.142264E+10 | 0.175347E+10 |
Annual Sum or Average | 0.177808E+11 | 0.652702E+10 | 0.112537E+11 | 0.347118E+11 | 0.833616E+10 |
Minimum of Months | 0.112643E+10 | 0.226030E+09 | 0.696899E+09 | 0.141638E+10 | 10604586.38 |
Maximum of Months | 0.203051E+10 | 0.952228E+09 | 0.114404E+10 | 0.467389E+10 | 0.180137E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.277714E+09 | 0.00 | 0.277714E+09 | 0.172187E+09 | 0.102444E+10 |
February | 0.297451E+09 | 0.00 | 0.297451E+09 | 0.303288E+09 | 0.696220E+09 |
March | 0.396833E+09 | 0.00 | 0.396833E+09 | 0.630975E+09 | 0.435986E+09 |
April | 0.416706E+09 | 1413190.22 | 0.415293E+09 | 0.103416E+10 | 0.138266E+09 |
May | 0.477070E+09 | 13387468.78 | 0.463682E+09 | 0.145944E+10 | 23635875.73 |
June | 0.477913E+09 | 17701986.81 | 0.460211E+09 | 0.151993E+10 | 19210260.66 |
July | 0.487042E+09 | 7712612.28 | 0.479330E+09 | 0.138714E+10 | 6112404.66 |
August | 0.447119E+09 | 1393469.71 | 0.445726E+09 | 0.116310E+10 | 20883628.37 |
September | 0.385544E+09 | 27072.11 | 0.385517E+09 | 0.878612E+09 | 76952369.14 |
October | 0.345140E+09 | 0.00 | 0.345140E+09 | 0.667602E+09 | 0.371700E+09 |
November | 0.282906E+09 | 0.00 | 0.282906E+09 | 0.355553E+09 | 0.697163E+09 |
December | 0.270915E+09 | 0.00 | 0.270915E+09 | 0.183716E+09 | 0.101424E+10 |
Annual Sum or Average | 0.456235E+10 | 41635799.91 | 0.452072E+10 | 0.975571E+10 | 0.452481E+10 |
Minimum of Months | 0.270915E+09 | 0.00 | 0.270915E+09 | 0.172187E+09 | 6112404.66 |
Maximum of Months | 0.487042E+09 | 17701986.81 | 0.479330E+09 | 0.151993E+10 | 0.102444E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.277731E+09 | 0.00 | 0.277731E+09 | 0.172198E+09 | 0.102450E+10 |
February | 0.297470E+09 | 0.00 | 0.297470E+09 | 0.303307E+09 | 0.696264E+09 |
March | 0.396859E+09 | 0.00 | 0.396859E+09 | 0.631015E+09 | 0.436014E+09 |
April | 0.416732E+09 | 1413279.53 | 0.415319E+09 | 0.103423E+10 | 0.138274E+09 |
May | 0.477100E+09 | 13388314.85 | 0.463712E+09 | 0.145954E+10 | 23637369.48 |
June | 0.477943E+09 | 17703105.55 | 0.460240E+09 | 0.152003E+10 | 19211474.72 |
July | 0.487073E+09 | 7713099.70 | 0.479360E+09 | 0.138723E+10 | 6112790.95 |
August | 0.447147E+09 | 1393557.78 | 0.445754E+09 | 0.116318E+10 | 20884948.18 |
September | 0.385569E+09 | 27073.82 | 0.385541E+09 | 0.878668E+09 | 76957232.41 |
October | 0.345161E+09 | 0.00 | 0.345161E+09 | 0.667644E+09 | 0.371724E+09 |
November | 0.282924E+09 | 0.00 | 0.282924E+09 | 0.355576E+09 | 0.697207E+09 |
December | 0.270932E+09 | 0.00 | 0.270932E+09 | 0.183728E+09 | 0.101431E+10 |
Annual Sum or Average | 0.456264E+10 | 41638431.23 | 0.452100E+10 | 0.975633E+10 | 0.452509E+10 |
Minimum of Months | 0.270932E+09 | 0.00 | 0.270932E+09 | 0.172198E+09 | 6112790.95 |
Maximum of Months | 0.487073E+09 | 17703105.55 | 0.479360E+09 | 0.152003E+10 | 0.102450E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.277731E+09 | 0.00 | 0.277731E+09 | 0.172198E+09 | 0.102450E+10 |
February | 0.297470E+09 | 0.00 | 0.297470E+09 | 0.303307E+09 | 0.696264E+09 |
March | 0.396859E+09 | 0.00 | 0.396859E+09 | 0.631015E+09 | 0.436014E+09 |
April | 0.416732E+09 | 1413279.53 | 0.415319E+09 | 0.103423E+10 | 0.138274E+09 |
May | 0.477100E+09 | 13388314.85 | 0.463712E+09 | 0.145954E+10 | 23637369.48 |
June | 0.477943E+09 | 17703105.55 | 0.460240E+09 | 0.152003E+10 | 19211474.72 |
July | 0.487073E+09 | 7713099.70 | 0.479360E+09 | 0.138723E+10 | 6112790.95 |
August | 0.447147E+09 | 1393557.78 | 0.445754E+09 | 0.116318E+10 | 20884948.18 |
September | 0.385569E+09 | 27073.82 | 0.385541E+09 | 0.878668E+09 | 76957232.41 |
October | 0.345161E+09 | 0.00 | 0.345161E+09 | 0.667644E+09 | 0.371724E+09 |
November | 0.282924E+09 | 0.00 | 0.282924E+09 | 0.355576E+09 | 0.697207E+09 |
December | 0.270932E+09 | 0.00 | 0.270932E+09 | 0.183728E+09 | 0.101431E+10 |
Annual Sum or Average | 0.456264E+10 | 41638431.23 | 0.452100E+10 | 0.975633E+10 | 0.452509E+10 |
Minimum of Months | 0.270932E+09 | 0.00 | 0.270932E+09 | 0.172198E+09 | 6112790.95 |
Maximum of Months | 0.487073E+09 | 17703105.55 | 0.479360E+09 | 0.152003E+10 | 0.102450E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.114461E+10 | 0.459429E+09 | 0.685182E+09 | 0.119852E+10 | 0.184255E+10 |
February | 0.125599E+10 | 0.518528E+09 | 0.737460E+09 | 0.165725E+10 | 0.128282E+10 |
March | 0.169633E+10 | 0.700183E+09 | 0.996150E+09 | 0.279448E+10 | 0.827603E+09 |
April | 0.195309E+10 | 0.910627E+09 | 0.104247E+10 | 0.399273E+10 | 0.284811E+09 |
May | 0.198646E+10 | 0.880683E+09 | 0.110578E+10 | 0.465605E+10 | 51223749.60 |
June | 0.156457E+10 | 0.519119E+09 | 0.104545E+10 | 0.404948E+10 | 39484497.30 |
July | 0.135881E+10 | 0.286943E+09 | 0.107187E+10 | 0.340637E+10 | 11447443.25 |
August | 0.122434E+10 | 0.213063E+09 | 0.101128E+10 | 0.287382E+10 | 42598938.62 |
September | 0.126588E+10 | 0.353019E+09 | 0.912857E+09 | 0.260864E+10 | 0.156018E+09 |
October | 0.143088E+10 | 0.577976E+09 | 0.852900E+09 | 0.262525E+10 | 0.714916E+09 |
November | 0.122775E+10 | 0.527005E+09 | 0.700750E+09 | 0.181517E+10 | 0.128705E+10 |
December | 0.110623E+10 | 0.438294E+09 | 0.667941E+09 | 0.123513E+10 | 0.184900E+10 |
Annual Sum or Average | 0.172150E+11 | 0.638487E+10 | 0.108301E+11 | 0.329129E+11 | 0.838952E+10 |
Minimum of Months | 0.110623E+10 | 0.213063E+09 | 0.667941E+09 | 0.119852E+10 | 11447443.25 |
Maximum of Months | 0.198646E+10 | 0.910627E+09 | 0.110578E+10 | 0.465605E+10 | 0.184900E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 45256880.33 | 18165390.84 | 27091489.49 | 47388551.35 | 72852875.69 |
February | 49660596.99 | 20502110.67 | 29158486.32 | 65526245.26 | 50721452.80 |
March | 67071487.52 | 27684618.38 | 39386869.13 | 0.110491E+09 | 32722669.22 |
April | 77223607.41 | 36005386.94 | 41218220.47 | 0.157869E+09 | 11261160.48 |
May | 78542882.67 | 34821423.98 | 43721458.69 | 0.184096E+09 | 2025340.94 |
June | 61861590.62 | 20525479.48 | 41336111.13 | 0.160113E+09 | 1561181.47 |
July | 53726120.05 | 11345452.90 | 42380667.15 | 0.134685E+09 | 452621.60 |
August | 48409458.90 | 8424331.93 | 39985126.97 | 0.113628E+09 | 1684323.68 |
September | 50051602.07 | 13958069.98 | 36093532.09 | 0.103143E+09 | 6168830.64 |
October | 56575568.36 | 22852664.97 | 33722903.39 | 0.103800E+09 | 28267133.24 |
November | 48544298.57 | 20837293.72 | 27707004.85 | 71770368.82 | 50888800.64 |
December | 43739531.01 | 17329763.55 | 26409767.46 | 48835888.13 | 73107658.69 |
Annual Sum or Average | 0.680664E+09 | 0.252452E+09 | 0.428212E+09 | 0.130135E+10 | 0.331714E+09 |
Minimum of Months | 43739531.01 | 8424331.93 | 26409767.46 | 47388551.35 | 452621.60 |
Maximum of Months | 78542882.67 | 36005386.94 | 43721458.69 | 0.184096E+09 | 73107658.69 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.126312E+10 | 0.767503E+09 | 0.495615E+09 | 0.175831E+10 | 0.986680E+09 |
February | 0.108481E+10 | 0.602535E+09 | 0.482277E+09 | 0.164226E+10 | 0.704182E+09 |
March | 0.102692E+10 | 0.453582E+09 | 0.573338E+09 | 0.181670E+10 | 0.462455E+09 |
April | 0.698044E+09 | 0.197009E+09 | 0.501034E+09 | 0.163173E+10 | 0.154842E+09 |
May | 0.518718E+09 | 38399260.52 | 0.480319E+09 | 0.154185E+10 | 24997861.87 |
June | 0.459188E+09 | 7835908.87 | 0.451352E+09 | 0.146271E+10 | 19598840.27 |
July | 0.494942E+09 | 6807525.18 | 0.488135E+09 | 0.139602E+10 | 5971790.35 |
August | 0.525029E+09 | 28040502.75 | 0.496988E+09 | 0.131212E+10 | 22296654.57 |
September | 0.681139E+09 | 0.176791E+09 | 0.504348E+09 | 0.144038E+10 | 87866650.26 |
October | 0.121089E+10 | 0.676156E+09 | 0.534734E+09 | 0.223072E+10 | 0.405581E+09 |
November | 0.146368E+10 | 0.967459E+09 | 0.496217E+09 | 0.237898E+10 | 0.721427E+09 |
December | 0.134984E+10 | 0.845846E+09 | 0.503992E+09 | 0.193746E+10 | 0.989646E+09 |
Annual Sum or Average | 0.107763E+11 | 0.476796E+10 | 0.600835E+10 | 0.205492E+11 | 0.458554E+10 |
Minimum of Months | 0.459188E+09 | 6807525.18 | 0.451352E+09 | 0.131212E+10 | 5971790.35 |
Maximum of Months | 0.146368E+10 | 0.967459E+09 | 0.573338E+09 | 0.237898E+10 | 0.989646E+09 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.126312E+10 | 0.767503E+09 | 0.495615E+09 | 0.175831E+10 | 0.986680E+09 |
February | 0.108481E+10 | 0.602535E+09 | 0.482277E+09 | 0.164226E+10 | 0.704182E+09 |
March | 0.102692E+10 | 0.453582E+09 | 0.573338E+09 | 0.181670E+10 | 0.462455E+09 |
April | 0.698044E+09 | 0.197009E+09 | 0.501034E+09 | 0.163173E+10 | 0.154842E+09 |
May | 0.518718E+09 | 38399260.52 | 0.480319E+09 | 0.154185E+10 | 24997861.87 |
June | 0.459188E+09 | 7835908.87 | 0.451352E+09 | 0.146271E+10 | 19598840.27 |
July | 0.494942E+09 | 6807525.18 | 0.488135E+09 | 0.139602E+10 | 5971790.35 |
August | 0.525029E+09 | 28040502.75 | 0.496988E+09 | 0.131212E+10 | 22296654.57 |
September | 0.681139E+09 | 0.176791E+09 | 0.504348E+09 | 0.144038E+10 | 87866650.26 |
October | 0.121089E+10 | 0.676156E+09 | 0.534734E+09 | 0.223072E+10 | 0.405581E+09 |
November | 0.146368E+10 | 0.967459E+09 | 0.496217E+09 | 0.237898E+10 | 0.721427E+09 |
December | 0.134984E+10 | 0.845846E+09 | 0.503992E+09 | 0.193746E+10 | 0.989646E+09 |
Annual Sum or Average | 0.107763E+11 | 0.476796E+10 | 0.600835E+10 | 0.205492E+11 | 0.458554E+10 |
Minimum of Months | 0.459188E+09 | 6807525.18 | 0.451352E+09 | 0.131212E+10 | 5971790.35 |
Maximum of Months | 0.146368E+10 | 0.967459E+09 | 0.573338E+09 | 0.237898E+10 | 0.989646E+09 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.126304E+10 | 0.767455E+09 | 0.495584E+09 | 0.175820E+10 | 0.986617E+09 |
February | 0.108474E+10 | 0.602497E+09 | 0.482246E+09 | 0.164216E+10 | 0.704137E+09 |
March | 0.102685E+10 | 0.453553E+09 | 0.573302E+09 | 0.181659E+10 | 0.462425E+09 |
April | 0.698000E+09 | 0.196997E+09 | 0.501003E+09 | 0.163163E+10 | 0.154833E+09 |
May | 0.518686E+09 | 38396833.90 | 0.480289E+09 | 0.154175E+10 | 24996282.15 |
June | 0.459159E+09 | 7835413.69 | 0.451323E+09 | 0.146262E+10 | 19597601.73 |
July | 0.494911E+09 | 6807094.98 | 0.488104E+09 | 0.139593E+10 | 5971412.96 |
August | 0.524996E+09 | 28038730.75 | 0.496957E+09 | 0.131204E+10 | 22295245.55 |
September | 0.681096E+09 | 0.176780E+09 | 0.504316E+09 | 0.144029E+10 | 87861097.58 |
October | 0.121081E+10 | 0.676113E+09 | 0.534700E+09 | 0.223058E+10 | 0.405555E+09 |
November | 0.146358E+10 | 0.967398E+09 | 0.496186E+09 | 0.237883E+10 | 0.721382E+09 |
December | 0.134975E+10 | 0.845792E+09 | 0.503960E+09 | 0.193734E+10 | 0.989584E+09 |
Annual Sum or Average | 0.107756E+11 | 0.476766E+10 | 0.600797E+10 | 0.205479E+11 | 0.458525E+10 |
Minimum of Months | 0.459159E+09 | 6807094.98 | 0.451323E+09 | 0.131204E+10 | 5971412.96 |
Maximum of Months | 0.146358E+10 | 0.967398E+09 | 0.573302E+09 | 0.237883E+10 | 0.989584E+09 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.111982E+10 | 0.435790E+09 | 0.684031E+09 | 0.131792E+10 | 0.198707E+10 |
February | 0.115662E+10 | 0.426244E+09 | 0.730377E+09 | 0.160013E+10 | 0.137703E+10 |
March | 0.166054E+10 | 0.663773E+09 | 0.996768E+09 | 0.279078E+10 | 0.891376E+09 |
April | 0.195326E+10 | 0.916001E+09 | 0.103726E+10 | 0.400540E+10 | 0.307610E+09 |
May | 0.191121E+10 | 0.810691E+09 | 0.110052E+10 | 0.452982E+10 | 59648902.16 |
June | 0.173723E+10 | 0.674782E+09 | 0.106245E+10 | 0.434562E+10 | 44027649.46 |
July | 0.133208E+10 | 0.259089E+09 | 0.107299E+10 | 0.334342E+10 | 13218396.52 |
August | 0.122338E+10 | 0.217430E+09 | 0.100595E+10 | 0.287281E+10 | 43832168.70 |
September | 0.130143E+10 | 0.382061E+09 | 0.919370E+09 | 0.267586E+10 | 0.166948E+09 |
October | 0.139974E+10 | 0.557373E+09 | 0.842371E+09 | 0.261453E+10 | 0.757647E+09 |
November | 0.122545E+10 | 0.522277E+09 | 0.703174E+09 | 0.191663E+10 | 0.138342E+10 |
December | 0.108358E+10 | 0.413191E+09 | 0.670388E+09 | 0.130531E+10 | 0.195329E+10 |
Annual Sum or Average | 0.171043E+11 | 0.627870E+10 | 0.108256E+11 | 0.333182E+11 | 0.898511E+10 |
Minimum of Months | 0.108358E+10 | 0.217430E+09 | 0.670388E+09 | 0.130531E+10 | 13218396.52 |
Maximum of Months | 0.195326E+10 | 0.916001E+09 | 0.110052E+10 | 0.452982E+10 | 0.198707E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 44276586.38 | 17230670.29 | 27045916.09 | 52109325.80 | 78566790.51 |
February | 45731645.95 | 16853253.85 | 28878392.10 | 63267383.89 | 54446507.86 |
March | 65656120.44 | 26244913.68 | 39411206.76 | 0.110345E+09 | 35244170.89 |
April | 77230036.37 | 36217725.41 | 41012310.96 | 0.158369E+09 | 12162585.07 |
May | 75567309.92 | 32053899.29 | 43513410.63 | 0.179105E+09 | 2358452.37 |
June | 68688264.83 | 26680196.85 | 42008067.98 | 0.171822E+09 | 1740809.36 |
July | 52669219.43 | 10244119.98 | 42425099.45 | 0.132195E+09 | 522640.42 |
August | 48371133.42 | 8596973.41 | 39774160.00 | 0.113588E+09 | 1733077.51 |
September | 51457307.89 | 15106316.67 | 36350991.22 | 0.105801E+09 | 6600942.82 |
October | 55344457.53 | 22037943.25 | 33306514.28 | 0.103376E+09 | 29956629.79 |
November | 48453078.47 | 20650287.21 | 27802791.25 | 75781571.64 | 54699190.20 |
December | 42843642.31 | 16337164.42 | 26506477.89 | 51610730.81 | 77231211.28 |
Annual Sum or Average | 0.676289E+09 | 0.248253E+09 | 0.428035E+09 | 0.131737E+10 | 0.355263E+09 |
Minimum of Months | 42843642.31 | 8596973.41 | 26506477.89 | 51610730.81 | 522640.42 |
Maximum of Months | 77230036.37 | 36217725.41 | 43513410.63 | 0.179105E+09 | 78566790.51 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.833180E+09 | 0.00 | 0.833180E+09 | 0.520862E+09 | 0.300272E+10 |
February | 0.892396E+09 | 0.00 | 0.892396E+09 | 0.884912E+09 | 0.211825E+10 |
March | 0.119056E+10 | 0.00 | 0.119056E+10 | 0.184361E+10 | 0.138501E+10 |
April | 0.125018E+10 | 4239771.25 | 0.124594E+10 | 0.304671E+10 | 0.469300E+09 |
May | 0.143128E+10 | 40164306.61 | 0.139111E+10 | 0.434074E+10 | 87306850.57 |
June | 0.143381E+10 | 53108473.11 | 0.138070E+10 | 0.455726E+10 | 61876406.45 |
July | 0.146120E+10 | 23138931.59 | 0.143806E+10 | 0.419434E+10 | 14873076.24 |
August | 0.134142E+10 | 4180606.92 | 0.133724E+10 | 0.354310E+10 | 49442685.24 |
September | 0.115669E+10 | 81220.16 | 0.115661E+10 | 0.268126E+10 | 0.197174E+09 |
October | 0.103547E+10 | 0.00 | 0.103547E+10 | 0.202870E+10 | 0.107765E+10 |
November | 0.848759E+09 | 0.00 | 0.848759E+09 | 0.108547E+10 | 0.202724E+10 |
December | 0.812782E+09 | 0.00 | 0.812782E+09 | 0.573552E+09 | 0.292990E+10 |
Annual Sum or Average | 0.136877E+11 | 0.124913E+09 | 0.135628E+11 | 0.293005E+11 | 0.134207E+11 |
Minimum of Months | 0.812782E+09 | 0.00 | 0.812782E+09 | 0.520862E+09 | 14873076.24 |
Maximum of Months | 0.146120E+10 | 53108473.11 | 0.143806E+10 | 0.455726E+10 | 0.300272E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_2_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.118988E+10 | 0.477599E+09 | 0.712278E+09 | 0.125990E+10 | 0.183642E+10 |
February | 0.130566E+10 | 0.539035E+09 | 0.766623E+09 | 0.170943E+10 | 0.131728E+10 |
March | 0.176342E+10 | 0.727875E+09 | 0.103554E+10 | 0.287281E+10 | 0.879820E+09 |
April | 0.203033E+10 | 0.946642E+09 | 0.108369E+10 | 0.412088E+10 | 0.313712E+09 |
May | 0.206502E+10 | 0.915514E+09 | 0.114950E+10 | 0.482872E+10 | 57151856.84 |
June | 0.162644E+10 | 0.539649E+09 | 0.108679E+10 | 0.421564E+10 | 41046874.31 |
July | 0.141255E+10 | 0.298291E+09 | 0.111426E+10 | 0.357232E+10 | 8863810.85 |
August | 0.127276E+10 | 0.221490E+09 | 0.105127E+10 | 0.302695E+10 | 33165626.94 |
September | 0.131594E+10 | 0.366981E+09 | 0.948956E+09 | 0.274251E+10 | 0.131214E+09 |
October | 0.148746E+10 | 0.600835E+09 | 0.886628E+09 | 0.274651E+10 | 0.699133E+09 |
November | 0.127631E+10 | 0.547848E+09 | 0.728460E+09 | 0.190258E+10 | 0.127300E+10 |
December | 0.114998E+10 | 0.455629E+09 | 0.694355E+09 | 0.130767E+10 | 0.182380E+10 |
Annual Sum or Average | 0.178957E+11 | 0.663739E+10 | 0.112584E+11 | 0.343059E+11 | 0.841460E+10 |
Minimum of Months | 0.114998E+10 | 0.221490E+09 | 0.694355E+09 | 0.125990E+10 | 8863810.85 |
Maximum of Months | 0.206502E+10 | 0.946642E+09 | 0.114950E+10 | 0.482872E+10 | 0.183642E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.378924E+10 | 0.230243E+10 | 0.148680E+10 | 0.523757E+10 | 0.283764E+10 |
February | 0.325433E+10 | 0.180755E+10 | 0.144679E+10 | 0.487973E+10 | 0.207759E+10 |
March | 0.308067E+10 | 0.136070E+10 | 0.171997E+10 | 0.540087E+10 | 0.141112E+10 |
April | 0.209407E+10 | 0.591009E+09 | 0.150306E+10 | 0.487887E+10 | 0.496438E+09 |
May | 0.155611E+10 | 0.115194E+09 | 0.144092E+10 | 0.465741E+10 | 84991867.23 |
June | 0.137753E+10 | 23506957.74 | 0.135402E+10 | 0.445032E+10 | 61135099.10 |
July | 0.148479E+10 | 20421907.57 | 0.146436E+10 | 0.426133E+10 | 13399507.39 |
August | 0.157504E+10 | 84118756.83 | 0.149092E+10 | 0.402164E+10 | 50454433.68 |
September | 0.204336E+10 | 0.530356E+09 | 0.151300E+10 | 0.439107E+10 | 0.208688E+09 |
October | 0.363256E+10 | 0.202840E+10 | 0.160416E+10 | 0.673970E+10 | 0.111644E+10 |
November | 0.439089E+10 | 0.290228E+10 | 0.148861E+10 | 0.713899E+10 | 0.202661E+10 |
December | 0.404938E+10 | 0.253745E+10 | 0.151193E+10 | 0.580620E+10 | 0.281103E+10 |
Annual Sum or Average | 0.323280E+11 | 0.143034E+11 | 0.180245E+11 | 0.618637E+11 | 0.131955E+11 |
Minimum of Months | 0.137753E+10 | 20421907.57 | 0.135402E+10 | 0.402164E+10 | 13399507.39 |
Maximum of Months | 0.439089E+10 | 0.290228E+10 | 0.171997E+10 | 0.713899E+10 | 0.283764E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_4_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.116411E+10 | 0.453025E+09 | 0.711081E+09 | 0.137465E+10 | 0.198399E+10 |
February | 0.120236E+10 | 0.443102E+09 | 0.759260E+09 | 0.164776E+10 | 0.141931E+10 |
March | 0.172621E+10 | 0.690025E+09 | 0.103618E+10 | 0.286863E+10 | 0.949381E+09 |
April | 0.203051E+10 | 0.952228E+09 | 0.107828E+10 | 0.413503E+10 | 0.336576E+09 |
May | 0.198679E+10 | 0.842754E+09 | 0.114404E+10 | 0.470265E+10 | 65245700.70 |
June | 0.180593E+10 | 0.701469E+09 | 0.110446E+10 | 0.452886E+10 | 44807391.84 |
July | 0.138476E+10 | 0.269336E+09 | 0.111543E+10 | 0.350503E+10 | 10422711.08 |
August | 0.127176E+10 | 0.226030E+09 | 0.104573E+10 | 0.302721E+10 | 34363733.34 |
September | 0.135290E+10 | 0.397172E+09 | 0.955727E+09 | 0.281128E+10 | 0.140016E+09 |
October | 0.145510E+10 | 0.579416E+09 | 0.875682E+09 | 0.273449E+10 | 0.740735E+09 |
November | 0.127391E+10 | 0.542933E+09 | 0.730980E+09 | 0.200524E+10 | 0.136798E+10 |
December | 0.112643E+10 | 0.429533E+09 | 0.696899E+09 | 0.137634E+10 | 0.192638E+10 |
Annual Sum or Average | 0.177808E+11 | 0.652702E+10 | 0.112537E+11 | 0.347172E+11 | 0.901921E+10 |
Minimum of Months | 0.112643E+10 | 0.226030E+09 | 0.696899E+09 | 0.137465E+10 | 10422711.08 |
Maximum of Months | 0.203051E+10 | 0.952228E+09 | 0.114404E+10 | 0.470265E+10 | 0.198399E+10 |
Report: WindowZoneSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 219.31 | 1012.32 | 311.07 | 0.00 | 311.07 | 0.00 | 0.00 |
February | 383.31 | 803.45 | 368.88 | 0.00 | 368.88 | 0.00 | 0.00 |
March | 690.19 | 485.85 | 444.50 | 0.00 | 444.50 | 0.00 | 0.00 |
April | 1164.21 | 174.98 | 482.32 | 1.64 | 480.69 | 0.00 | 0.00 |
May | 1604.27 | 32.96 | 534.38 | 15.00 | 519.38 | 0.00 | 0.00 |
June | 1740.40 | 24.21 | 553.17 | 20.49 | 532.68 | 0.00 | 0.00 |
July | 1549.40 | 5.61 | 545.55 | 8.64 | 536.91 | 0.00 | 0.00 |
August | 1309.10 | 18.33 | 500.83 | 1.56 | 499.27 | 0.00 | 0.00 |
September | 1027.00 | 72.72 | 446.25 | 0.03 | 446.22 | 0.00 | 0.00 |
October | 756.05 | 380.14 | 386.60 | 0.00 | 386.60 | 0.00 | 0.00 |
November | 433.01 | 720.28 | 327.45 | 0.00 | 327.45 | 0.00 | 0.00 |
December | 240.71 | 990.80 | 303.46 | 0.00 | 303.46 | 0.00 | 0.00 |
Annual Sum or Average | 929.07 | 391.70 | 434.03 | 3.96 | 430.07 | 0.00 | 0.00 |
Minimum of Months | 219.31 | 5.61 | 303.46 | 0.00 | 303.46 | 0.00 | 0.00 |
Maximum of Months | 1740.40 | 1012.32 | 553.17 | 20.49 | 536.91 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 493.83 | 625.46 | 444.25 | 178.31 | 265.93 | 0.00 | 0.00 |
February | 720.20 | 505.97 | 539.71 | 222.82 | 316.89 | 0.00 | 0.00 |
March | 1073.50 | 312.13 | 658.38 | 271.76 | 386.63 | 0.00 | 0.00 |
April | 1580.56 | 117.80 | 783.31 | 365.22 | 418.09 | 0.00 | 0.00 |
May | 1790.18 | 21.60 | 770.99 | 341.81 | 429.18 | 0.00 | 0.00 |
June | 1613.48 | 16.12 | 627.48 | 208.20 | 419.29 | 0.00 | 0.00 |
July | 1322.30 | 3.32 | 527.38 | 111.37 | 416.02 | 0.00 | 0.00 |
August | 1120.51 | 12.37 | 475.20 | 82.69 | 392.50 | 0.00 | 0.00 |
September | 1052.25 | 48.66 | 507.69 | 141.58 | 366.11 | 0.00 | 0.00 |
October | 1024.23 | 248.67 | 555.36 | 224.33 | 331.03 | 0.00 | 0.00 |
November | 744.93 | 458.05 | 492.40 | 211.36 | 281.04 | 0.00 | 0.00 |
December | 510.99 | 624.80 | 429.35 | 170.11 | 259.24 | 0.00 | 0.00 |
Annual Sum or Average | 1088.50 | 248.45 | 567.47 | 210.47 | 357.00 | 0.00 | 0.00 |
Minimum of Months | 493.83 | 3.32 | 429.35 | 82.69 | 259.24 | 0.00 | 0.00 |
Maximum of Months | 1790.18 | 625.46 | 783.31 | 365.22 | 429.18 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1981.94 | 969.41 | 1414.74 | 859.63 | 555.11 | 0.00 | 0.00 |
February | 2031.17 | 797.72 | 1345.21 | 747.17 | 598.04 | 0.00 | 0.00 |
March | 2015.21 | 499.12 | 1150.19 | 508.03 | 642.16 | 0.00 | 0.00 |
April | 1869.18 | 185.43 | 807.90 | 228.01 | 579.89 | 0.00 | 0.00 |
May | 1722.40 | 31.92 | 580.99 | 43.01 | 537.98 | 0.00 | 0.00 |
June | 1699.31 | 23.97 | 531.45 | 9.07 | 522.38 | 0.00 | 0.00 |
July | 1574.71 | 4.98 | 554.36 | 7.62 | 546.73 | 0.00 | 0.00 |
August | 1487.56 | 18.73 | 588.05 | 31.41 | 556.65 | 0.00 | 0.00 |
September | 1684.77 | 77.36 | 788.33 | 204.61 | 583.72 | 0.00 | 0.00 |
October | 2512.95 | 397.15 | 1356.24 | 757.32 | 598.92 | 0.00 | 0.00 |
November | 2763.41 | 730.93 | 1694.02 | 1119.71 | 574.31 | 0.00 | 0.00 |
December | 2194.19 | 966.83 | 1511.87 | 947.38 | 564.49 | 0.00 | 0.00 |
Annual Sum or Average | 1960.36 | 390.14 | 1025.11 | 453.56 | 571.55 | 0.00 | 0.00 |
Minimum of Months | 1487.56 | 4.98 | 531.45 | 7.62 | 522.38 | 0.00 | 0.00 |
Maximum of Months | 2763.41 | 969.41 | 1694.02 | 1119.71 | 642.16 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 528.82 | 672.56 | 434.63 | 169.14 | 265.49 | 0.00 | 0.00 |
February | 691.91 | 540.34 | 497.01 | 183.16 | 313.85 | 0.00 | 0.00 |
March | 1071.74 | 333.92 | 644.49 | 257.63 | 386.87 | 0.00 | 0.00 |
April | 1587.14 | 125.61 | 783.37 | 367.37 | 416.00 | 0.00 | 0.00 |
May | 1745.03 | 24.37 | 741.78 | 314.65 | 427.13 | 0.00 | 0.00 |
June | 1735.83 | 17.30 | 696.73 | 270.63 | 426.10 | 0.00 | 0.00 |
July | 1298.63 | 3.96 | 517.01 | 100.56 | 416.45 | 0.00 | 0.00 |
August | 1121.54 | 12.74 | 474.82 | 84.39 | 390.43 | 0.00 | 0.00 |
September | 1079.60 | 51.60 | 521.95 | 153.23 | 368.72 | 0.00 | 0.00 |
October | 1020.13 | 261.78 | 543.27 | 216.33 | 326.94 | 0.00 | 0.00 |
November | 782.62 | 487.83 | 491.48 | 209.46 | 282.01 | 0.00 | 0.00 |
December | 531.15 | 654.67 | 420.56 | 160.37 | 260.19 | 0.00 | 0.00 |
Annual Sum or Average | 1100.70 | 264.34 | 563.82 | 206.97 | 356.85 | 0.00 | 0.00 |
Minimum of Months | 528.82 | 3.96 | 420.56 | 84.39 | 260.19 | 0.00 | 0.00 |
Maximum of Months | 1745.03 | 672.56 | 783.37 | 367.37 | 427.13 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 192.87 | 1147.49 | 311.07 | 0.00 | 311.07 | 0.00 | 0.00 |
February | 376.12 | 863.40 | 368.88 | 0.00 | 368.88 | 0.00 | 0.00 |
March | 706.77 | 488.36 | 444.50 | 0.00 | 444.50 | 0.00 | 0.00 |
April | 1196.99 | 160.04 | 482.32 | 1.64 | 480.68 | 0.00 | 0.00 |
May | 1634.75 | 26.47 | 534.37 | 15.00 | 519.38 | 0.00 | 0.00 |
June | 1759.25 | 22.24 | 553.16 | 20.49 | 532.67 | 0.00 | 0.00 |
July | 1553.76 | 6.85 | 545.55 | 8.64 | 536.91 | 0.00 | 0.00 |
August | 1302.81 | 23.39 | 500.83 | 1.56 | 499.27 | 0.00 | 0.00 |
September | 1016.96 | 89.07 | 446.25 | 0.03 | 446.22 | 0.00 | 0.00 |
October | 747.79 | 416.35 | 386.60 | 0.00 | 386.60 | 0.00 | 0.00 |
November | 411.54 | 806.94 | 327.45 | 0.00 | 327.45 | 0.00 | 0.00 |
December | 205.78 | 1136.07 | 303.46 | 0.00 | 303.46 | 0.00 | 0.00 |
Annual Sum or Average | 928.09 | 430.46 | 434.03 | 3.96 | 430.07 | 0.00 | 0.00 |
Minimum of Months | 192.87 | 6.85 | 303.46 | 0.00 | 303.46 | 0.00 | 0.00 |
Maximum of Months | 1759.25 | 1147.49 | 553.16 | 20.49 | 536.91 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 465.17 | 715.13 | 444.25 | 178.31 | 265.93 | 0.00 | 0.00 |
February | 712.13 | 551.23 | 539.70 | 222.81 | 316.89 | 0.00 | 0.00 |
March | 1084.59 | 321.21 | 658.38 | 271.75 | 386.63 | 0.00 | 0.00 |
April | 1601.31 | 114.23 | 783.30 | 365.21 | 418.09 | 0.00 | 0.00 |
May | 1807.11 | 19.88 | 770.98 | 341.81 | 429.17 | 0.00 | 0.00 |
June | 1624.07 | 15.84 | 627.48 | 208.20 | 419.28 | 0.00 | 0.00 |
July | 1322.08 | 4.44 | 527.38 | 111.37 | 416.01 | 0.00 | 0.00 |
August | 1115.39 | 16.53 | 475.19 | 82.69 | 392.50 | 0.00 | 0.00 |
September | 1046.21 | 62.57 | 507.69 | 141.58 | 366.11 | 0.00 | 0.00 |
October | 1018.91 | 277.47 | 555.35 | 224.32 | 331.03 | 0.00 | 0.00 |
November | 727.99 | 516.18 | 492.40 | 211.36 | 281.04 | 0.00 | 0.00 |
December | 479.38 | 717.63 | 429.35 | 170.11 | 259.24 | 0.00 | 0.00 |
Annual Sum or Average | 1084.93 | 276.55 | 567.47 | 210.47 | 357.00 | 0.00 | 0.00 |
Minimum of Months | 465.17 | 4.44 | 429.35 | 82.69 | 259.24 | 0.00 | 0.00 |
Maximum of Months | 1807.11 | 717.63 | 783.30 | 365.21 | 429.17 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1969.40 | 1105.13 | 1414.75 | 859.64 | 555.11 | 0.00 | 0.00 |
February | 2036.49 | 873.22 | 1345.22 | 747.18 | 598.05 | 0.00 | 0.00 |
March | 2034.80 | 517.97 | 1150.20 | 508.03 | 642.17 | 0.00 | 0.00 |
April | 1888.54 | 179.21 | 807.90 | 228.02 | 579.89 | 0.00 | 0.00 |
May | 1726.94 | 28.00 | 580.99 | 43.01 | 537.98 | 0.00 | 0.00 |
June | 1692.92 | 22.68 | 531.46 | 9.07 | 522.39 | 0.00 | 0.00 |
July | 1563.61 | 6.69 | 554.36 | 7.62 | 546.73 | 0.00 | 0.00 |
August | 1469.64 | 24.97 | 588.06 | 31.41 | 556.65 | 0.00 | 0.00 |
September | 1667.07 | 101.70 | 788.34 | 204.61 | 583.72 | 0.00 | 0.00 |
October | 2498.51 | 454.27 | 1356.25 | 757.33 | 598.93 | 0.00 | 0.00 |
November | 2753.39 | 834.97 | 1694.03 | 1119.72 | 574.31 | 0.00 | 0.00 |
December | 2170.05 | 1108.45 | 1511.88 | 947.39 | 564.50 | 0.00 | 0.00 |
Annual Sum or Average | 1954.80 | 436.21 | 1025.12 | 453.56 | 571.56 | 0.00 | 0.00 |
Minimum of Months | 1469.64 | 6.69 | 531.46 | 7.62 | 522.39 | 0.00 | 0.00 |
Maximum of Months | 2753.39 | 1108.45 | 1694.03 | 1119.72 | 642.17 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 511.51 | 771.22 | 434.62 | 169.14 | 265.49 | 0.00 | 0.00 |
February | 687.58 | 591.71 | 497.00 | 183.16 | 313.85 | 0.00 | 0.00 |
March | 1083.16 | 345.96 | 644.49 | 257.62 | 386.86 | 0.00 | 0.00 |
April | 1606.39 | 123.37 | 783.37 | 367.37 | 416.00 | 0.00 | 0.00 |
May | 1758.11 | 23.15 | 741.78 | 314.65 | 427.13 | 0.00 | 0.00 |
June | 1742.84 | 17.66 | 696.73 | 270.63 | 426.10 | 0.00 | 0.00 |
July | 1297.64 | 5.13 | 517.01 | 100.56 | 416.45 | 0.00 | 0.00 |
August | 1114.99 | 17.01 | 474.82 | 84.39 | 390.43 | 0.00 | 0.00 |
September | 1073.17 | 66.96 | 521.95 | 153.23 | 368.72 | 0.00 | 0.00 |
October | 1014.75 | 294.06 | 543.27 | 216.33 | 326.94 | 0.00 | 0.00 |
November | 768.68 | 554.83 | 491.48 | 209.46 | 282.01 | 0.00 | 0.00 |
December | 506.62 | 758.11 | 420.56 | 160.37 | 260.19 | 0.00 | 0.00 |
Annual Sum or Average | 1098.29 | 296.18 | 563.82 | 206.97 | 356.85 | 0.00 | 0.00 |
Minimum of Months | 506.62 | 5.13 | 420.56 | 84.39 | 260.19 | 0.00 | 0.00 |
Maximum of Months | 1758.11 | 771.22 | 783.37 | 367.37 | 427.13 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 194.47 | 1121.09 | 311.07 | 0.00 | 311.07 | 0.00 | 0.00 |
February | 365.79 | 875.60 | 368.88 | 0.00 | 368.88 | 0.00 | 0.00 |
March | 688.32 | 517.10 | 444.50 | 0.00 | 444.50 | 0.00 | 0.00 |
April | 1175.43 | 181.06 | 482.32 | 1.64 | 480.69 | 0.00 | 0.00 |
May | 1620.65 | 32.60 | 534.38 | 15.00 | 519.38 | 0.00 | 0.00 |
June | 1758.20 | 23.87 | 553.17 | 20.49 | 532.68 | 0.00 | 0.00 |
July | 1565.99 | 5.55 | 545.55 | 8.64 | 536.91 | 0.00 | 0.00 |
August | 1322.84 | 18.46 | 500.83 | 1.56 | 499.27 | 0.00 | 0.00 |
September | 1034.44 | 76.07 | 446.25 | 0.03 | 446.22 | 0.00 | 0.00 |
October | 757.43 | 402.35 | 386.60 | 0.00 | 386.60 | 0.00 | 0.00 |
November | 418.78 | 782.11 | 327.45 | 0.00 | 327.45 | 0.00 | 0.00 |
December | 214.14 | 1093.90 | 303.46 | 0.00 | 303.46 | 0.00 | 0.00 |
Annual Sum or Average | 929.11 | 425.57 | 434.03 | 3.96 | 430.07 | 0.00 | 0.00 |
Minimum of Months | 194.47 | 5.55 | 303.46 | 0.00 | 303.46 | 0.00 | 0.00 |
Maximum of Months | 1758.20 | 1121.09 | 553.17 | 20.49 | 536.91 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 470.39 | 685.64 | 444.25 | 178.31 | 265.93 | 0.00 | 0.00 |
February | 706.61 | 544.51 | 539.71 | 222.82 | 316.89 | 0.00 | 0.00 |
March | 1072.58 | 328.49 | 658.38 | 271.76 | 386.63 | 0.00 | 0.00 |
April | 1589.85 | 121.03 | 783.31 | 365.22 | 418.09 | 0.00 | 0.00 |
May | 1802.84 | 21.34 | 770.99 | 341.81 | 429.18 | 0.00 | 0.00 |
June | 1626.40 | 15.84 | 627.48 | 208.20 | 419.29 | 0.00 | 0.00 |
July | 1333.75 | 3.31 | 527.38 | 111.37 | 416.02 | 0.00 | 0.00 |
August | 1130.13 | 12.38 | 475.20 | 82.69 | 392.50 | 0.00 | 0.00 |
September | 1058.07 | 50.62 | 507.69 | 141.58 | 366.11 | 0.00 | 0.00 |
October | 1025.43 | 261.03 | 555.36 | 224.33 | 331.03 | 0.00 | 0.00 |
November | 734.02 | 491.13 | 492.40 | 211.36 | 281.04 | 0.00 | 0.00 |
December | 488.23 | 680.93 | 429.35 | 170.11 | 259.24 | 0.00 | 0.00 |
Annual Sum or Average | 1087.83 | 266.83 | 567.47 | 210.47 | 357.00 | 0.00 | 0.00 |
Minimum of Months | 470.39 | 3.31 | 429.35 | 82.69 | 259.24 | 0.00 | 0.00 |
Maximum of Months | 1802.84 | 685.64 | 783.31 | 365.22 | 429.18 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1955.48 | 1059.45 | 1414.74 | 859.63 | 555.11 | 0.00 | 0.00 |
February | 2017.09 | 858.79 | 1345.21 | 747.17 | 598.04 | 0.00 | 0.00 |
March | 2016.45 | 526.85 | 1150.19 | 508.03 | 642.16 | 0.00 | 0.00 |
April | 1882.28 | 191.53 | 807.90 | 228.01 | 579.89 | 0.00 | 0.00 |
May | 1738.88 | 31.73 | 580.99 | 43.01 | 537.98 | 0.00 | 0.00 |
June | 1716.95 | 23.59 | 531.45 | 9.07 | 522.38 | 0.00 | 0.00 |
July | 1591.00 | 5.00 | 554.36 | 7.62 | 546.73 | 0.00 | 0.00 |
August | 1501.51 | 18.84 | 588.05 | 31.41 | 556.65 | 0.00 | 0.00 |
September | 1694.09 | 80.51 | 788.33 | 204.61 | 583.72 | 0.00 | 0.00 |
October | 2516.31 | 416.83 | 1356.24 | 757.32 | 598.92 | 0.00 | 0.00 |
November | 2754.24 | 781.87 | 1694.02 | 1119.71 | 574.31 | 0.00 | 0.00 |
December | 2167.79 | 1049.52 | 1511.87 | 947.38 | 564.49 | 0.00 | 0.00 |
Annual Sum or Average | 1961.68 | 418.43 | 1025.11 | 453.56 | 571.55 | 0.00 | 0.00 |
Minimum of Months | 1501.51 | 5.00 | 531.45 | 7.62 | 522.38 | 0.00 | 0.00 |
Maximum of Months | 2754.24 | 1059.45 | 1694.02 | 1119.71 | 642.16 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 513.23 | 740.74 | 434.63 | 169.14 | 265.49 | 0.00 | 0.00 |
February | 681.12 | 586.69 | 497.01 | 183.16 | 313.85 | 0.00 | 0.00 |
March | 1071.02 | 354.46 | 644.49 | 257.63 | 386.87 | 0.00 | 0.00 |
April | 1595.31 | 129.85 | 783.37 | 367.37 | 416.00 | 0.00 | 0.00 |
May | 1755.77 | 24.36 | 741.78 | 314.65 | 427.13 | 0.00 | 0.00 |
June | 1747.25 | 17.29 | 696.73 | 270.63 | 426.10 | 0.00 | 0.00 |
July | 1308.63 | 3.89 | 517.01 | 100.56 | 416.45 | 0.00 | 0.00 |
August | 1130.23 | 12.83 | 474.82 | 84.39 | 390.43 | 0.00 | 0.00 |
September | 1084.60 | 54.02 | 521.95 | 153.23 | 368.72 | 0.00 | 0.00 |
October | 1020.94 | 276.56 | 543.27 | 216.33 | 326.94 | 0.00 | 0.00 |
November | 773.63 | 527.77 | 491.48 | 209.46 | 282.01 | 0.00 | 0.00 |
December | 513.87 | 719.23 | 420.56 | 160.37 | 260.19 | 0.00 | 0.00 |
Annual Sum or Average | 1100.87 | 286.00 | 563.82 | 206.97 | 356.85 | 0.00 | 0.00 |
Minimum of Months | 513.23 | 3.89 | 420.56 | 84.39 | 260.19 | 0.00 | 0.00 |
Maximum of Months | 1755.77 | 740.74 | 783.37 | 367.37 | 427.13 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.587398E+09 | 0.271140E+10 | 0.833180E+09 | 0.00 | 0.833180E+09 | 0.00 | 0.00 |
February | 0.927293E+09 | 0.194371E+10 | 0.892396E+09 | 0.00 | 0.892396E+09 | 0.00 | 0.00 |
March | 0.184859E+10 | 0.130129E+10 | 0.119056E+10 | 0.00 | 0.119056E+10 | 0.00 | 0.00 |
April | 0.301762E+10 | 0.453540E+09 | 0.125018E+10 | 4239771.25 | 0.124594E+10 | 0.00 | 0.00 |
May | 0.429689E+10 | 88270215.15 | 0.143128E+10 | 40164306.61 | 0.139111E+10 | 0.00 | 0.00 |
June | 0.451111E+10 | 62759231.66 | 0.143381E+10 | 53108473.11 | 0.138070E+10 | 0.00 | 0.00 |
July | 0.414990E+10 | 15025873.94 | 0.146120E+10 | 23138931.59 | 0.143806E+10 | 0.00 | 0.00 |
August | 0.350629E+10 | 49095283.03 | 0.134142E+10 | 4180606.92 | 0.133724E+10 | 0.00 | 0.00 |
September | 0.266199E+10 | 0.188495E+09 | 0.115669E+10 | 81220.16 | 0.115661E+10 | 0.00 | 0.00 |
October | 0.202501E+10 | 0.101818E+10 | 0.103547E+10 | 0.00 | 0.103547E+10 | 0.00 | 0.00 |
November | 0.112237E+10 | 0.186698E+10 | 0.848759E+09 | 0.00 | 0.848759E+09 | 0.00 | 0.00 |
December | 0.644725E+09 | 0.265376E+10 | 0.812782E+09 | 0.00 | 0.812782E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.292992E+11 | 0.123525E+11 | 0.136877E+11 | 0.124913E+09 | 0.135628E+11 | 0.00 | 0.00 |
Minimum of Months | 0.587398E+09 | 15025873.94 | 0.812782E+09 | 0.00 | 0.812782E+09 | 0.00 | 0.00 |
Maximum of Months | 0.451111E+10 | 0.271140E+10 | 0.146120E+10 | 53108473.11 | 0.143806E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.132267E+10 | 0.167523E+10 | 0.118988E+10 | 0.477599E+09 | 0.712278E+09 | 0.00 | 0.00 |
February | 0.174230E+10 | 0.122404E+10 | 0.130566E+10 | 0.539035E+09 | 0.766623E+09 | 0.00 | 0.00 |
March | 0.287526E+10 | 0.836019E+09 | 0.176342E+10 | 0.727875E+09 | 0.103554E+10 | 0.00 | 0.00 |
April | 0.409680E+10 | 0.305335E+09 | 0.203033E+10 | 0.946642E+09 | 0.108369E+10 | 0.00 | 0.00 |
May | 0.479482E+10 | 57848383.12 | 0.206502E+10 | 0.915514E+09 | 0.114950E+10 | 0.00 | 0.00 |
June | 0.418215E+10 | 41793993.27 | 0.162644E+10 | 0.539649E+09 | 0.108679E+10 | 0.00 | 0.00 |
July | 0.354164E+10 | 8905204.90 | 0.141255E+10 | 0.298291E+09 | 0.111426E+10 | 0.00 | 0.00 |
August | 0.300116E+10 | 33134535.49 | 0.127276E+10 | 0.221490E+09 | 0.105127E+10 | 0.00 | 0.00 |
September | 0.272743E+10 | 0.126116E+09 | 0.131594E+10 | 0.366981E+09 | 0.948956E+09 | 0.00 | 0.00 |
October | 0.274329E+10 | 0.666035E+09 | 0.148746E+10 | 0.600835E+09 | 0.886628E+09 | 0.00 | 0.00 |
November | 0.193086E+10 | 0.118728E+10 | 0.127631E+10 | 0.547848E+09 | 0.728460E+09 | 0.00 | 0.00 |
December | 0.136865E+10 | 0.167346E+10 | 0.114998E+10 | 0.455629E+09 | 0.694355E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.343270E+11 | 0.783520E+10 | 0.178957E+11 | 0.663739E+10 | 0.112584E+11 | 0.00 | 0.00 |
Minimum of Months | 0.132267E+10 | 8905204.90 | 0.114998E+10 | 0.221490E+09 | 0.694355E+09 | 0.00 | 0.00 |
Maximum of Months | 0.479482E+10 | 0.167523E+10 | 0.206502E+10 | 0.946642E+09 | 0.114950E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.530844E+10 | 0.259648E+10 | 0.378924E+10 | 0.230243E+10 | 0.148680E+10 | 0.00 | 0.00 |
February | 0.491381E+10 | 0.192985E+10 | 0.325433E+10 | 0.180755E+10 | 0.144679E+10 | 0.00 | 0.00 |
March | 0.539753E+10 | 0.133685E+10 | 0.308067E+10 | 0.136070E+10 | 0.171997E+10 | 0.00 | 0.00 |
April | 0.484490E+10 | 0.480640E+09 | 0.209407E+10 | 0.591009E+09 | 0.150306E+10 | 0.00 | 0.00 |
May | 0.461327E+10 | 85489449.41 | 0.155611E+10 | 0.115194E+09 | 0.144092E+10 | 0.00 | 0.00 |
June | 0.440462E+10 | 62132777.19 | 0.137753E+10 | 23506957.74 | 0.135402E+10 | 0.00 | 0.00 |
July | 0.421770E+10 | 13349956.20 | 0.148479E+10 | 20421907.57 | 0.146436E+10 | 0.00 | 0.00 |
August | 0.398429E+10 | 50163291.91 | 0.157504E+10 | 84118756.83 | 0.149092E+10 | 0.00 | 0.00 |
September | 0.436692E+10 | 0.200520E+09 | 0.204336E+10 | 0.530356E+09 | 0.151300E+10 | 0.00 | 0.00 |
October | 0.673069E+10 | 0.106372E+10 | 0.363256E+10 | 0.202840E+10 | 0.160416E+10 | 0.00 | 0.00 |
November | 0.716275E+10 | 0.189457E+10 | 0.439089E+10 | 0.290228E+10 | 0.148861E+10 | 0.00 | 0.00 |
December | 0.587691E+10 | 0.258957E+10 | 0.404938E+10 | 0.253745E+10 | 0.151193E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.618218E+11 | 0.123033E+11 | 0.323280E+11 | 0.143034E+11 | 0.180245E+11 | 0.00 | 0.00 |
Minimum of Months | 0.398429E+10 | 13349956.20 | 0.137753E+10 | 20421907.57 | 0.135402E+10 | 0.00 | 0.00 |
Maximum of Months | 0.716275E+10 | 0.259648E+10 | 0.439089E+10 | 0.290228E+10 | 0.171997E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.141638E+10 | 0.180137E+10 | 0.116411E+10 | 0.453025E+09 | 0.711081E+09 | 0.00 | 0.00 |
February | 0.167388E+10 | 0.130718E+10 | 0.120236E+10 | 0.443102E+09 | 0.759260E+09 | 0.00 | 0.00 |
March | 0.287054E+10 | 0.894377E+09 | 0.172621E+10 | 0.690025E+09 | 0.103618E+10 | 0.00 | 0.00 |
April | 0.411387E+10 | 0.325573E+09 | 0.203051E+10 | 0.952228E+09 | 0.107828E+10 | 0.00 | 0.00 |
May | 0.467389E+10 | 65279390.31 | 0.198679E+10 | 0.842754E+09 | 0.114404E+10 | 0.00 | 0.00 |
June | 0.449928E+10 | 44834772.81 | 0.180593E+10 | 0.701469E+09 | 0.110446E+10 | 0.00 | 0.00 |
July | 0.347825E+10 | 10604586.38 | 0.138476E+10 | 0.269336E+09 | 0.111543E+10 | 0.00 | 0.00 |
August | 0.300392E+10 | 34135640.96 | 0.127176E+10 | 0.226030E+09 | 0.104573E+10 | 0.00 | 0.00 |
September | 0.279831E+10 | 0.133747E+09 | 0.135290E+10 | 0.397172E+09 | 0.955727E+09 | 0.00 | 0.00 |
October | 0.273231E+10 | 0.701142E+09 | 0.145510E+10 | 0.579416E+09 | 0.875682E+09 | 0.00 | 0.00 |
November | 0.202854E+10 | 0.126445E+10 | 0.127391E+10 | 0.542933E+09 | 0.730980E+09 | 0.00 | 0.00 |
December | 0.142264E+10 | 0.175347E+10 | 0.112643E+10 | 0.429533E+09 | 0.696899E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.347118E+11 | 0.833616E+10 | 0.177808E+11 | 0.652702E+10 | 0.112537E+11 | 0.00 | 0.00 |
Minimum of Months | 0.141638E+10 | 10604586.38 | 0.112643E+10 | 0.226030E+09 | 0.696899E+09 | 0.00 | 0.00 |
Maximum of Months | 0.467389E+10 | 0.180137E+10 | 0.203051E+10 | 0.952228E+09 | 0.114404E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.516583E+09 | 0.307344E+10 | 0.833176E+09 | 0.00 | 0.833176E+09 | 0.00 | 0.00 |
February | 0.909903E+09 | 0.208875E+10 | 0.892392E+09 | 0.00 | 0.892392E+09 | 0.00 | 0.00 |
March | 0.189300E+10 | 0.130801E+10 | 0.119055E+10 | 0.00 | 0.119055E+10 | 0.00 | 0.00 |
April | 0.310261E+10 | 0.414814E+09 | 0.125017E+10 | 4239749.28 | 0.124593E+10 | 0.00 | 0.00 |
May | 0.437852E+10 | 70910614.69 | 0.143127E+10 | 40164098.49 | 0.139111E+10 | 0.00 | 0.00 |
June | 0.455999E+10 | 57633210.10 | 0.143380E+10 | 53108197.92 | 0.138069E+10 | 0.00 | 0.00 |
July | 0.416160E+10 | 18337986.57 | 0.146119E+10 | 23138811.69 | 0.143805E+10 | 0.00 | 0.00 |
August | 0.348945E+10 | 62653524.73 | 0.134141E+10 | 4180585.26 | 0.133723E+10 | 0.00 | 0.00 |
September | 0.263595E+10 | 0.230867E+09 | 0.115668E+10 | 81219.74 | 0.115660E+10 | 0.00 | 0.00 |
October | 0.200289E+10 | 0.111515E+10 | 0.103546E+10 | 0.00 | 0.103546E+10 | 0.00 | 0.00 |
November | 0.106670E+10 | 0.209158E+10 | 0.848755E+09 | 0.00 | 0.848755E+09 | 0.00 | 0.00 |
December | 0.551172E+09 | 0.304286E+10 | 0.812778E+09 | 0.00 | 0.812778E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.292684E+11 | 0.135750E+11 | 0.136876E+11 | 0.124913E+09 | 0.135627E+11 | 0.00 | 0.00 |
Minimum of Months | 0.516583E+09 | 18337986.57 | 0.812778E+09 | 0.00 | 0.812778E+09 | 0.00 | 0.00 |
Maximum of Months | 0.455999E+10 | 0.307344E+10 | 0.146119E+10 | 53108197.92 | 0.143805E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.124591E+10 | 0.191541E+10 | 0.118987E+10 | 0.477594E+09 | 0.712274E+09 | 0.00 | 0.00 |
February | 0.172278E+10 | 0.133354E+10 | 0.130565E+10 | 0.539030E+09 | 0.766618E+09 | 0.00 | 0.00 |
March | 0.290497E+10 | 0.860325E+09 | 0.176340E+10 | 0.727868E+09 | 0.103554E+10 | 0.00 | 0.00 |
April | 0.415059E+10 | 0.296072E+09 | 0.203032E+10 | 0.946633E+09 | 0.108369E+10 | 0.00 | 0.00 |
May | 0.484015E+10 | 53249090.54 | 0.206500E+10 | 0.915505E+09 | 0.114950E+10 | 0.00 | 0.00 |
June | 0.420959E+10 | 41045678.77 | 0.162643E+10 | 0.539644E+09 | 0.108679E+10 | 0.00 | 0.00 |
July | 0.354105E+10 | 11900064.85 | 0.141254E+10 | 0.298288E+09 | 0.111425E+10 | 0.00 | 0.00 |
August | 0.298745E+10 | 44283262.30 | 0.127275E+10 | 0.221488E+09 | 0.105127E+10 | 0.00 | 0.00 |
September | 0.271178E+10 | 0.162187E+09 | 0.131593E+10 | 0.366977E+09 | 0.948950E+09 | 0.00 | 0.00 |
October | 0.272905E+10 | 0.743183E+09 | 0.148745E+10 | 0.600829E+09 | 0.886623E+09 | 0.00 | 0.00 |
November | 0.188694E+10 | 0.133794E+10 | 0.127630E+10 | 0.547842E+09 | 0.728457E+09 | 0.00 | 0.00 |
December | 0.128396E+10 | 0.192210E+10 | 0.114997E+10 | 0.455624E+09 | 0.694350E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.342142E+11 | 0.872123E+10 | 0.178956E+11 | 0.663732E+10 | 0.112583E+11 | 0.00 | 0.00 |
Minimum of Months | 0.124591E+10 | 11900064.85 | 0.114997E+10 | 0.221488E+09 | 0.694350E+09 | 0.00 | 0.00 |
Maximum of Months | 0.484015E+10 | 0.192210E+10 | 0.206500E+10 | 0.946633E+09 | 0.114950E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.527483E+10 | 0.295998E+10 | 0.378927E+10 | 0.230246E+10 | 0.148681E+10 | 0.00 | 0.00 |
February | 0.492668E+10 | 0.211250E+10 | 0.325437E+10 | 0.180757E+10 | 0.144680E+10 | 0.00 | 0.00 |
March | 0.545000E+10 | 0.138733E+10 | 0.308069E+10 | 0.136072E+10 | 0.171998E+10 | 0.00 | 0.00 |
April | 0.489510E+10 | 0.464518E+09 | 0.209409E+10 | 0.591016E+09 | 0.150307E+10 | 0.00 | 0.00 |
May | 0.462545E+10 | 74992005.90 | 0.155612E+10 | 0.115195E+09 | 0.144093E+10 | 0.00 | 0.00 |
June | 0.438804E+10 | 58795282.26 | 0.137753E+10 | 23507231.43 | 0.135403E+10 | 0.00 | 0.00 |
July | 0.418797E+10 | 17914993.65 | 0.148480E+10 | 20422145.35 | 0.146437E+10 | 0.00 | 0.00 |
August | 0.393629E+10 | 66888554.68 | 0.157505E+10 | 84119736.24 | 0.149093E+10 | 0.00 | 0.00 |
September | 0.432104E+10 | 0.263594E+09 | 0.204337E+10 | 0.530362E+09 | 0.151301E+10 | 0.00 | 0.00 |
October | 0.669201E+10 | 0.121672E+10 | 0.363259E+10 | 0.202843E+10 | 0.160417E+10 | 0.00 | 0.00 |
November | 0.713678E+10 | 0.216424E+10 | 0.439094E+10 | 0.290232E+10 | 0.148862E+10 | 0.00 | 0.00 |
December | 0.581225E+10 | 0.296888E+10 | 0.404943E+10 | 0.253748E+10 | 0.151194E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.616464E+11 | 0.137563E+11 | 0.323283E+11 | 0.143036E+11 | 0.180247E+11 | 0.00 | 0.00 |
Minimum of Months | 0.393629E+10 | 17914993.65 | 0.137753E+10 | 20422145.35 | 0.135403E+10 | 0.00 | 0.00 |
Maximum of Months | 0.713678E+10 | 0.296888E+10 | 0.439094E+10 | 0.290232E+10 | 0.171998E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.137003E+10 | 0.206563E+10 | 0.116410E+10 | 0.453020E+09 | 0.711077E+09 | 0.00 | 0.00 |
February | 0.166339E+10 | 0.143148E+10 | 0.120235E+10 | 0.443097E+09 | 0.759256E+09 | 0.00 | 0.00 |
March | 0.290113E+10 | 0.926620E+09 | 0.172620E+10 | 0.690018E+09 | 0.103618E+10 | 0.00 | 0.00 |
April | 0.416377E+10 | 0.319772E+09 | 0.203049E+10 | 0.952218E+09 | 0.107827E+10 | 0.00 | 0.00 |
May | 0.470893E+10 | 62007354.52 | 0.198678E+10 | 0.842745E+09 | 0.114403E+10 | 0.00 | 0.00 |
June | 0.451744E+10 | 45768458.82 | 0.180592E+10 | 0.701462E+09 | 0.110445E+10 | 0.00 | 0.00 |
July | 0.347561E+10 | 13741036.94 | 0.138475E+10 | 0.269333E+09 | 0.111542E+10 | 0.00 | 0.00 |
August | 0.298640E+10 | 45565246.21 | 0.127175E+10 | 0.226027E+09 | 0.104572E+10 | 0.00 | 0.00 |
September | 0.278166E+10 | 0.173549E+09 | 0.135289E+10 | 0.397168E+09 | 0.955721E+09 | 0.00 | 0.00 |
October | 0.271791E+10 | 0.787603E+09 | 0.145509E+10 | 0.579411E+09 | 0.875677E+09 | 0.00 | 0.00 |
November | 0.199241E+10 | 0.143812E+10 | 0.127390E+10 | 0.542927E+09 | 0.730976E+09 | 0.00 | 0.00 |
December | 0.135692E+10 | 0.203052E+10 | 0.112642E+10 | 0.429529E+09 | 0.696895E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.346356E+11 | 0.934038E+10 | 0.177806E+11 | 0.652696E+10 | 0.112537E+11 | 0.00 | 0.00 |
Minimum of Months | 0.135692E+10 | 13741036.94 | 0.112642E+10 | 0.226027E+09 | 0.696895E+09 | 0.00 | 0.00 |
Maximum of Months | 0.470893E+10 | 0.206563E+10 | 0.203049E+10 | 0.952218E+09 | 0.114403E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.520862E+09 | 0.300272E+10 | 0.833180E+09 | 0.00 | 0.833180E+09 | 0.00 | 0.00 |
February | 0.884912E+09 | 0.211825E+10 | 0.892396E+09 | 0.00 | 0.892396E+09 | 0.00 | 0.00 |
March | 0.184361E+10 | 0.138501E+10 | 0.119056E+10 | 0.00 | 0.119056E+10 | 0.00 | 0.00 |
April | 0.304671E+10 | 0.469300E+09 | 0.125018E+10 | 4239771.25 | 0.124594E+10 | 0.00 | 0.00 |
May | 0.434074E+10 | 87306850.57 | 0.143128E+10 | 40164306.61 | 0.139111E+10 | 0.00 | 0.00 |
June | 0.455726E+10 | 61876406.45 | 0.143381E+10 | 53108473.11 | 0.138070E+10 | 0.00 | 0.00 |
July | 0.419434E+10 | 14873076.24 | 0.146120E+10 | 23138931.59 | 0.143806E+10 | 0.00 | 0.00 |
August | 0.354310E+10 | 49442685.24 | 0.134142E+10 | 4180606.92 | 0.133724E+10 | 0.00 | 0.00 |
September | 0.268126E+10 | 0.197174E+09 | 0.115669E+10 | 81220.16 | 0.115661E+10 | 0.00 | 0.00 |
October | 0.202870E+10 | 0.107765E+10 | 0.103547E+10 | 0.00 | 0.103547E+10 | 0.00 | 0.00 |
November | 0.108547E+10 | 0.202724E+10 | 0.848759E+09 | 0.00 | 0.848759E+09 | 0.00 | 0.00 |
December | 0.573552E+09 | 0.292990E+10 | 0.812782E+09 | 0.00 | 0.812782E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.293005E+11 | 0.134207E+11 | 0.136877E+11 | 0.124913E+09 | 0.135628E+11 | 0.00 | 0.00 |
Minimum of Months | 0.520862E+09 | 14873076.24 | 0.812782E+09 | 0.00 | 0.812782E+09 | 0.00 | 0.00 |
Maximum of Months | 0.455726E+10 | 0.300272E+10 | 0.146120E+10 | 53108473.11 | 0.143806E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.125990E+10 | 0.183642E+10 | 0.118988E+10 | 0.477599E+09 | 0.712278E+09 | 0.00 | 0.00 |
February | 0.170943E+10 | 0.131728E+10 | 0.130566E+10 | 0.539035E+09 | 0.766623E+09 | 0.00 | 0.00 |
March | 0.287281E+10 | 0.879820E+09 | 0.176342E+10 | 0.727875E+09 | 0.103554E+10 | 0.00 | 0.00 |
April | 0.412088E+10 | 0.313712E+09 | 0.203033E+10 | 0.946642E+09 | 0.108369E+10 | 0.00 | 0.00 |
May | 0.482872E+10 | 57151856.84 | 0.206502E+10 | 0.915514E+09 | 0.114950E+10 | 0.00 | 0.00 |
June | 0.421564E+10 | 41046874.31 | 0.162644E+10 | 0.539649E+09 | 0.108679E+10 | 0.00 | 0.00 |
July | 0.357232E+10 | 8863810.85 | 0.141255E+10 | 0.298291E+09 | 0.111426E+10 | 0.00 | 0.00 |
August | 0.302695E+10 | 33165626.94 | 0.127276E+10 | 0.221490E+09 | 0.105127E+10 | 0.00 | 0.00 |
September | 0.274251E+10 | 0.131214E+09 | 0.131594E+10 | 0.366981E+09 | 0.948956E+09 | 0.00 | 0.00 |
October | 0.274651E+10 | 0.699133E+09 | 0.148746E+10 | 0.600835E+09 | 0.886628E+09 | 0.00 | 0.00 |
November | 0.190258E+10 | 0.127300E+10 | 0.127631E+10 | 0.547848E+09 | 0.728460E+09 | 0.00 | 0.00 |
December | 0.130767E+10 | 0.182380E+10 | 0.114998E+10 | 0.455629E+09 | 0.694355E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.343059E+11 | 0.841460E+10 | 0.178957E+11 | 0.663739E+10 | 0.112584E+11 | 0.00 | 0.00 |
Minimum of Months | 0.125990E+10 | 8863810.85 | 0.114998E+10 | 0.221490E+09 | 0.694355E+09 | 0.00 | 0.00 |
Maximum of Months | 0.482872E+10 | 0.183642E+10 | 0.206502E+10 | 0.946642E+09 | 0.114950E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.523757E+10 | 0.283764E+10 | 0.378924E+10 | 0.230243E+10 | 0.148680E+10 | 0.00 | 0.00 |
February | 0.487973E+10 | 0.207759E+10 | 0.325433E+10 | 0.180755E+10 | 0.144679E+10 | 0.00 | 0.00 |
March | 0.540087E+10 | 0.141112E+10 | 0.308067E+10 | 0.136070E+10 | 0.171997E+10 | 0.00 | 0.00 |
April | 0.487887E+10 | 0.496438E+09 | 0.209407E+10 | 0.591009E+09 | 0.150306E+10 | 0.00 | 0.00 |
May | 0.465741E+10 | 84991867.23 | 0.155611E+10 | 0.115194E+09 | 0.144092E+10 | 0.00 | 0.00 |
June | 0.445032E+10 | 61135099.10 | 0.137753E+10 | 23506957.74 | 0.135402E+10 | 0.00 | 0.00 |
July | 0.426133E+10 | 13399507.39 | 0.148479E+10 | 20421907.57 | 0.146436E+10 | 0.00 | 0.00 |
August | 0.402164E+10 | 50454433.68 | 0.157504E+10 | 84118756.83 | 0.149092E+10 | 0.00 | 0.00 |
September | 0.439107E+10 | 0.208688E+09 | 0.204336E+10 | 0.530356E+09 | 0.151300E+10 | 0.00 | 0.00 |
October | 0.673970E+10 | 0.111644E+10 | 0.363256E+10 | 0.202840E+10 | 0.160416E+10 | 0.00 | 0.00 |
November | 0.713899E+10 | 0.202661E+10 | 0.439089E+10 | 0.290228E+10 | 0.148861E+10 | 0.00 | 0.00 |
December | 0.580620E+10 | 0.281103E+10 | 0.404938E+10 | 0.253745E+10 | 0.151193E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.618637E+11 | 0.131955E+11 | 0.323280E+11 | 0.143034E+11 | 0.180245E+11 | 0.00 | 0.00 |
Minimum of Months | 0.402164E+10 | 13399507.39 | 0.137753E+10 | 20421907.57 | 0.135402E+10 | 0.00 | 0.00 |
Maximum of Months | 0.713899E+10 | 0.283764E+10 | 0.439089E+10 | 0.290228E+10 | 0.171997E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.137465E+10 | 0.198399E+10 | 0.116411E+10 | 0.453025E+09 | 0.711081E+09 | 0.00 | 0.00 |
February | 0.164776E+10 | 0.141931E+10 | 0.120236E+10 | 0.443102E+09 | 0.759260E+09 | 0.00 | 0.00 |
March | 0.286863E+10 | 0.949381E+09 | 0.172621E+10 | 0.690025E+09 | 0.103618E+10 | 0.00 | 0.00 |
April | 0.413503E+10 | 0.336576E+09 | 0.203051E+10 | 0.952228E+09 | 0.107828E+10 | 0.00 | 0.00 |
May | 0.470265E+10 | 65245700.70 | 0.198679E+10 | 0.842754E+09 | 0.114404E+10 | 0.00 | 0.00 |
June | 0.452886E+10 | 44807391.84 | 0.180593E+10 | 0.701469E+09 | 0.110446E+10 | 0.00 | 0.00 |
July | 0.350503E+10 | 10422711.08 | 0.138476E+10 | 0.269336E+09 | 0.111543E+10 | 0.00 | 0.00 |
August | 0.302721E+10 | 34363733.34 | 0.127176E+10 | 0.226030E+09 | 0.104573E+10 | 0.00 | 0.00 |
September | 0.281128E+10 | 0.140016E+09 | 0.135290E+10 | 0.397172E+09 | 0.955727E+09 | 0.00 | 0.00 |
October | 0.273449E+10 | 0.740735E+09 | 0.145510E+10 | 0.579416E+09 | 0.875682E+09 | 0.00 | 0.00 |
November | 0.200524E+10 | 0.136798E+10 | 0.127391E+10 | 0.542933E+09 | 0.730980E+09 | 0.00 | 0.00 |
December | 0.137634E+10 | 0.192638E+10 | 0.112643E+10 | 0.429533E+09 | 0.696899E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.347172E+11 | 0.901921E+10 | 0.177808E+11 | 0.652702E+10 | 0.112537E+11 | 0.00 | 0.00 |
Minimum of Months | 0.137465E+10 | 10422711.08 | 0.112643E+10 | 0.226030E+09 | 0.696899E+09 | 0.00 | 0.00 |
Maximum of Months | 0.470265E+10 | 0.198399E+10 | 0.203051E+10 | 0.952228E+09 | 0.114404E+10 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | 13.39 | 10.38 | 7.87 | 1.20 | 0.38 | 63.33 | 149.51 | 0.00 |
February | 16.97 | 12.78 | 9.69 | 1.81 | 4.63 | 75.94 | 163.32 | 0.01 |
March | 22.37 | 15.60 | 11.23 | 1.86 | 10.07 | 92.70 | 193.23 | 0.00 |
April | 29.13 | 18.33 | 11.93 | 1.64 | 16.17 | 89.20 | 259.84 | 0.01 |
May | 32.98 | 21.97 | 16.72 | 2.17 | 21.14 | 97.31 | 248.85 | 0.02 |
June | 33.59 | 24.39 | 20.62 | 1.55 | 23.45 | 107.22 | 203.36 | 0.06 |
July | 31.67 | 26.29 | 24.51 | 2.27 | 24.88 | 132.35 | 83.14 | 0.02 |
August | 30.03 | 26.31 | 25.11 | 1.75 | 23.81 | 127.44 | 60.46 | 0.00 |
September | 28.75 | 24.70 | 23.21 | 1.33 | 20.22 | 105.62 | 105.60 | 0.08 |
October | 25.09 | 18.74 | 15.36 | 0.77 | 12.83 | 75.09 | 190.08 | 0.00 |
November | 19.63 | 14.46 | 10.99 | 0.66 | 5.78 | 58.54 | 201.10 | 0.00 |
December | 14.52 | 10.88 | 7.89 | 0.97 | 0.94 | 60.91 | 153.60 | 0.01 |
Annual Sum or Average | 24.88 | 18.77 | 15.46 | 1.50 | 13.74 | 90.59 | 167.44 | 0.02 |
Minimum of Months | 13.39 | 10.38 | 7.87 | 0.66 | 0.38 | 58.54 | 60.46 | 0.00 |
Maximum of Months | 33.59 | 26.31 | 25.11 | 2.27 | 24.88 | 132.35 | 259.84 | 0.08 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 23.60 | 12-JAN-14:00 | 14.20 | 7.40 | 3.80 | 8.15 | 163.00 | 476.00 |
February | 27.10 | 22-FEB-14:00 | 16.20 | 9.10 | 1.50 | 15.39 | 225.00 | 451.00 |
March | 35.60 | 28-MAR-14:00 | 18.50 | 7.70 | 0.00 | 19.52 | 182.00 | 699.00 |
April | 40.30 | 15-APR-14:00 | 20.67 | 10.00 | 6.70 | 28.43 | 201.00 | 649.50 |
May | 44.50 | 03-MAY-14:00 | 20.64 | 5.30 | 2.80 | 28.91 | 150.00 | 809.00 |
June | 44.60 | 07-JUN-15:00 | 21.53 | 9.10 | 3.10 | 28.43 | 167.00 | 640.50 |
July | 40.40 | 02-JUL-15:00 | 26.36 | 21.60 | 2.10 | 29.87 | 200.00 | 545.50 |
August | 37.30 | 07-AUG-14:00 | 26.58 | 22.90 | 3.00 | 29.87 | 311.00 | 370.00 |
September | 37.50 | 17-SEP-19:00 | 27.68 | 24.60 | 0.20 | 28.59 | 0.00 | 0.00 |
October | 36.40 | 02-OCT-14:20 | 21.05 | 13.00 | 1.80 | 21.61 | 187.33 | 678.83 |
November | 30.30 | 04-NOV-13:00 | 17.17 | 8.90 | 1.10 | 14.84 | 155.00 | 710.00 |
December | 24.60 | 28-DEC-13:00 | 15.30 | 8.90 | 2.80 | 10.88 | 181.50 | 535.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 23.60 | 14.20 | 5.30 | 0.00 | 8.15 | 0.00 | 0.00 | |
Maximum of Months | 44.60 | 27.68 | 24.60 | 6.70 | 29.87 | 311.00 | 809.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 4.80 | 05-JAN-06:00 | 4.73 | 4.60 | 0.00 | -10.2 | 0.00 | 0.00 |
February | 6.90 | 02-FEB-05:00 | 6.67 | 6.50 | 0.00 | -7.8 | 0.00 | 0.00 |
March | 13.30 | 01-MAR-03:00 | 10.56 | 8.30 | 0.80 | -1.4 | 0.00 | 0.00 |
April | 17.40 | 11-APR-04:00 | 13.58 | 10.90 | 0.00 | 3.06 | 0.00 | 0.00 |
May | 22.70 | 13-MAY-04:00 | 20.32 | 19.30 | 2.10 | 20.40 | 0.00 | 0.00 |
June | 23.30 | 18-JUN-04:00 | 21.80 | 21.20 | 2.70 | 17.75 | 0.00 | 0.00 |
July | 23.20 | 19-JUL-02:00 | 23.20 | 23.20 | 2.30 | 15.39 | 0.00 | 0.00 |
August | 23.40 | 15-AUG-23:00 | 22.91 | 22.80 | 2.40 | 21.78 | 0.00 | 0.00 |
September | 23.00 | 27-SEP-04:00 | 20.74 | 19.70 | 0.00 | 10.30 | 0.00 | 0.00 |
October | 15.50 | 31-OCT-04:00 | 14.07 | 13.20 | 0.00 | 1.80 | 0.00 | 0.00 |
November | 9.50 | 27-NOV-05:00 | 8.75 | 8.10 | 0.00 | -5.0 | 0.00 | 0.00 |
December | 5.00 | 21-DEC-04:00 | 4.08 | 3.00 | 0.00 | -10.5 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 4.80 | 4.08 | 3.00 | 0.00 | -10.5 | 0.00 | 0.00 | |
Maximum of Months | 23.40 | 23.20 | 23.20 | 2.70 | 21.78 | 0.00 | 0.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 15.62 | 17-JAN-14:00 | 18.20 | 14.10 | 1.00 | 11.07 | 198.00 | 56.50 |
February | 18.14 | 25-FEB-16:00 | 21.20 | 16.60 | 5.90 | 10.88 | 107.50 | 156.50 |
March | 21.38 | 10-MAR-18:49 | 29.25 | 17.73 | 2.10 | 21.44 | 0.00 | 0.00 |
April | 23.42 | 18-APR-13:00 | 37.10 | 17.80 | 5.70 | 23.49 | 233.50 | 671.50 |
May | 27.40 | 22-MAY-22:00 | 29.40 | 26.80 | 0.00 | 20.40 | 0.00 | 0.00 |
June | 28.92 | 28-JUN-12:00 | 34.40 | 27.50 | 1.00 | 25.49 | 332.50 | 501.50 |
July | 29.18 | 01-JUL-16:00 | 37.20 | 26.80 | 2.30 | 25.66 | 196.00 | 196.00 |
August | 29.17 | 27-AUG-15:00 | 35.10 | 27.40 | 1.30 | 29.55 | 256.00 | 129.00 |
September | 28.10 | 14-SEP-16:00 | 33.70 | 26.40 | 1.40 | 26.48 | 122.50 | 108.50 |
October | 23.06 | 06-OCT-10:00 | 28.60 | 20.80 | 1.30 | 20.22 | 327.00 | 348.50 |
November | 18.93 | 08-NOV-17:10 | 27.55 | 14.47 | 0.17 | 16.67 | 28.00 | 65.33 |
December | 15.64 | 29-DEC-19:00 | 16.80 | 14.90 | 4.80 | 13.54 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 15.62 | 16.80 | 14.10 | 0.00 | 10.88 | 0.00 | 0.00 | |
Maximum of Months | 29.18 | 37.20 | 27.50 | 5.90 | 29.55 | 332.50 | 671.50 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 14.10 | 17-JAN-13:00 | 17.80 | 15.48 | 0.90 | 9.72 | 260.50 | 81.50 |
February | 16.60 | 25-FEB-16:00 | 21.20 | 18.14 | 5.90 | 10.88 | 107.50 | 156.50 |
March | 18.30 | 10-MAR-19:00 | 27.70 | 21.26 | 2.10 | 21.44 | 0.00 | 0.00 |
April | 19.30 | 26-APR-23:10 | 28.53 | 22.04 | 0.00 | 15.61 | 0.00 | 0.00 |
May | 26.80 | 22-MAY-22:00 | 29.40 | 27.40 | 0.00 | 20.40 | 0.00 | 0.00 |
June | 27.50 | 28-JUN-12:00 | 34.40 | 28.92 | 1.00 | 25.49 | 332.50 | 501.50 |
July | 27.30 | 18-JUL-06:19 | 29.10 | 27.70 | 1.17 | 26.48 | 20.00 | 0.00 |
August | 28.80 | 12-AUG-07:00 | 29.10 | 28.83 | 2.90 | 26.81 | 113.00 | 6.50 |
September | 26.50 | 12-SEP-14:00 | 30.50 | 27.38 | 0.90 | 25.99 | 260.00 | 20.00 |
October | 21.10 | 06-OCT-08:00 | 25.50 | 22.41 | 0.30 | 17.21 | 239.00 | 159.00 |
November | 16.30 | 08-NOV-21:19 | 20.10 | 17.59 | 0.00 | 10.95 | 0.00 | 0.00 |
December | 14.90 | 29-DEC-20:10 | 16.72 | 15.59 | 4.73 | 13.13 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 14.10 | 16.72 | 15.48 | 0.00 | 9.72 | 0.00 | 0.00 | |
Maximum of Months | 28.80 | 34.40 | 28.92 | 5.90 | 26.81 | 332.50 | 501.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 20.92 | 27.26 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 21.74 | 33.91 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 24.21 | 44.04 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 27.79 | 55.91 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 31.48 | 58.43 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 34.27 | 54.82 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 35.42 | 39.75 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 34.60 | 34.68 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 32.04 | 35.55 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 28.44 | 39.44 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 24.77 | 33.85 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 22.02 | 26.79 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 28.18 | 40.37 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 20.92 | 26.79 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 35.42 | 58.43 | 0.00 |
Report: WaterHeaterReportMonthly
For: SWHSYS1 WATER HEATER
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.429175E+10 | -0.359766E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -694086600.2 | 58.98 | 0.00 | 0.00 |
February | 0.382470E+10 | -0.320070E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -624002823.8 | 58.98 | 0.00 | 0.00 |
March | 0.422359E+10 | -0.353368E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -689913999.0 | 58.98 | 0.00 | 0.00 |
April | 0.351950E+10 | -0.285436E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -665139386.0 | 58.98 | 0.00 | 0.00 |
May | 0.339545E+10 | -0.270640E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -689046695.9 | 58.98 | 0.00 | 0.00 |
June | 0.307766E+10 | -0.240940E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -668267391.6 | 58.98 | 0.00 | 0.00 |
July | 0.285454E+10 | -0.216486E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -689673650.5 | 58.98 | 0.00 | 0.00 |
August | 0.316883E+10 | -0.247966E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -689175785.4 | 58.97 | 0.00 | 0.00 |
September | 0.313606E+10 | -0.247139E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -664663356.1 | 58.98 | 0.00 | 0.00 |
October | 0.357738E+10 | -0.288998E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -687396580.1 | 58.98 | 0.00 | 0.00 |
November | 0.384568E+10 | -0.317951E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -666169939.2 | 58.98 | 0.00 | 0.00 |
December | 0.408933E+10 | -0.339770E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -691632059.9 | 58.98 | 0.00 | 0.00 |
Annual Sum or Average | 0.430045E+11 | -0.348853E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.811917E+10 | 58.98 | 0.00 | 0.00 |
Minimum of Months | 0.285454E+10 | -0.359766E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -694086600.2 | 58.97 | 0.00 | 0.00 |
Maximum of Months | 0.429175E+10 | -0.216486E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -624002823.8 | 58.98 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_1_DAYLCTRL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 319.33 | 0.64 | 0.62 | 01-JAN-07:49 | 5406.13 | 34.90 | 297.33 | 286.17 | 1176.32 | 24.65 | 205.67 | 264.83 |
February | 303.83 | 0.64 | 0.62 | 01-FEB-07:49 | 3200.54 | 28.08 | 196.17 | 270.17 | 1034.61 | 20.36 | 121.83 | 241.17 |
March | 364.50 | 0.64 | 0.62 | 01-MAR-07:40 | 1605.06 | 17.85 | 7.50 | 319.17 | 881.28 | 20.26 | 111.17 | 287.00 |
April | 379.83 | 0.65 | 0.62 | 01-APR-07:10 | 1067.01 | 16.33 | 0.00 | 324.67 | 637.72 | 18.98 | 22.83 | 288.67 |
May | 406.00 | 0.65 | 0.62 | 01-MAY-06:40 | 897.44 | 16.05 | 0.00 | 346.00 | 530.07 | 18.81 | 2.83 | 302.83 |
June | 386.67 | 0.65 | 0.62 | 01-JUN-06:00 | 890.46 | 15.72 | 0.00 | 330.83 | 512.73 | 18.43 | 0.00 | 283.00 |
July | 379.83 | 0.64 | 0.62 | 01-JUL-06:40 | 1014.10 | 16.17 | 0.00 | 328.83 | 528.95 | 18.79 | 4.67 | 271.83 |
August | 372.50 | 0.65 | 0.62 | 01-AUG-06:40 | 1147.74 | 16.20 | 0.00 | 317.00 | 578.76 | 18.78 | 43.67 | 264.17 |
September | 344.33 | 0.64 | 0.62 | 01-SEP-06:00 | 1400.77 | 16.92 | 0.00 | 298.17 | 732.25 | 19.60 | 98.33 | 257.00 |
October | 347.33 | 0.65 | 0.62 | 01-OCT-06:00 | 2427.26 | 19.00 | 41.33 | 305.17 | 997.07 | 20.12 | 122.67 | 275.67 |
November | 317.83 | 0.64 | 0.62 | 01-NOV-07:10 | 7348.42 | 35.38 | 301.67 | 282.50 | 1234.46 | 23.96 | 176.83 | 269.17 |
December | 315.50 | 0.64 | 0.62 | 01-DEC-07:30 | 5695.39 | 35.24 | 296.17 | 283.83 | 1390.64 | 26.93 | 213.33 | 277.50 |
Annual Sum or Average | 4237.50 | 0.64 | 2517.61 | 21.70 | 1140.17 | 3692.50 | 829.02 | 20.62 | 1123.83 | 3282.83 | ||
Minimum of Months | 303.83 | 0.64 | 0.62 | 890.46 | 15.72 | 0.00 | 270.17 | 512.73 | 18.43 | 0.00 | 241.17 | |
Maximum of Months | 406.00 | 0.65 | 0.62 | 7348.42 | 35.38 | 301.67 | 346.00 | 1390.64 | 26.93 | 213.33 | 302.83 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_2_DAYLCTRL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 319.33 | 0.65 | 0.62 | 01-JAN-07:49 | 1498.00 | 18.98 | 85.50 | 258.33 | 818.31 | 22.23 | 77.33 | 211.00 |
February | 303.83 | 0.65 | 0.62 | 01-FEB-07:49 | 1920.60 | 21.11 | 99.67 | 252.83 | 1017.93 | 22.31 | 74.00 | 208.00 |
March | 364.50 | 0.64 | 0.62 | 01-MAR-07:30 | 1805.56 | 18.99 | 88.17 | 311.17 | 928.78 | 20.51 | 57.33 | 274.67 |
April | 379.83 | 0.65 | 0.62 | 01-APR-06:49 | 2239.27 | 19.83 | 110.17 | 322.00 | 1177.14 | 21.22 | 81.17 | 290.33 |
May | 406.00 | 0.64 | 0.62 | 01-MAY-06:10 | 2321.15 | 19.15 | 116.50 | 350.83 | 882.08 | 19.28 | 55.17 | 312.17 |
June | 386.67 | 0.65 | 0.62 | 01-JUN-06:40 | 1835.52 | 18.17 | 100.67 | 332.33 | 760.30 | 19.22 | 51.00 | 289.67 |
July | 379.83 | 0.64 | 0.62 | 01-JUL-05:00 | 1514.06 | 18.26 | 96.33 | 333.00 | 670.81 | 18.80 | 40.83 | 272.33 |
August | 372.50 | 0.64 | 0.62 | 01-AUG-06:19 | 1386.23 | 18.14 | 96.17 | 317.33 | 638.12 | 18.81 | 42.17 | 257.00 |
September | 344.33 | 0.64 | 0.62 | 01-SEP-06:49 | 1528.71 | 17.75 | 73.00 | 292.67 | 787.95 | 20.83 | 64.50 | 246.67 |
October | 347.33 | 0.65 | 0.62 | 01-OCT-06:49 | 1691.36 | 18.69 | 87.00 | 289.83 | 864.55 | 21.24 | 70.17 | 254.00 |
November | 317.83 | 0.65 | 0.62 | 01-NOV-06:00 | 1527.00 | 19.42 | 84.17 | 260.67 | 778.94 | 20.95 | 58.33 | 221.00 |
December | 315.50 | 0.65 | 0.62 | 01-DEC-07:30 | 1557.46 | 19.37 | 87.83 | 253.00 | 865.23 | 22.86 | 81.67 | 215.83 |
Annual Sum or Average | 4237.50 | 0.65 | 1747.43 | 18.95 | 1125.17 | 3574.00 | 847.91 | 20.59 | 753.67 | 3052.67 | ||
Minimum of Months | 303.83 | 0.64 | 0.62 | 1386.23 | 17.75 | 73.00 | 252.83 | 638.12 | 18.80 | 40.83 | 208.00 | |
Maximum of Months | 406.00 | 0.65 | 0.62 | 2321.15 | 21.11 | 116.50 | 350.83 | 1177.14 | 22.86 | 81.67 | 312.17 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_3_DAYLCTRL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 319.33 | 0.66 | 0.62 | 01-JAN-08:30 | 487.66 | 13.62 | 0.00 | 236.00 | 304.30 | 16.54 | 0.00 | 136.17 |
February | 303.83 | 0.65 | 0.62 | 01-FEB-08:20 | 563.18 | 14.53 | 0.00 | 243.50 | 349.63 | 17.39 | 0.00 | 164.50 |
March | 364.50 | 0.64 | 0.62 | 01-MAR-07:00 | 666.39 | 15.71 | 0.00 | 308.17 | 412.63 | 18.49 | 0.00 | 251.00 |
April | 379.83 | 0.65 | 0.62 | 01-APR-07:10 | 717.89 | 15.89 | 0.00 | 329.17 | 451.37 | 18.56 | 0.00 | 290.00 |
May | 406.00 | 0.64 | 0.62 | 01-MAY-06:19 | 863.61 | 16.53 | 1.17 | 363.33 | 511.04 | 19.31 | 7.50 | 330.83 |
June | 386.67 | 0.64 | 0.62 | 01-JUN-06:49 | 962.28 | 17.24 | 17.17 | 345.33 | 543.91 | 21.11 | 80.33 | 310.67 |
July | 379.83 | 0.63 | 0.62 | 01-JUL-06:10 | 988.15 | 17.17 | 14.50 | 341.33 | 519.48 | 20.51 | 48.33 | 288.67 |
August | 372.50 | 0.64 | 0.62 | 01-AUG-06:40 | 884.64 | 15.87 | 0.00 | 321.67 | 463.91 | 18.41 | 0.00 | 262.17 |
September | 344.33 | 0.64 | 0.62 | 01-SEP-06:00 | 762.68 | 15.70 | 0.00 | 294.67 | 426.93 | 18.31 | 0.00 | 232.33 |
October | 347.33 | 0.65 | 0.62 | 01-OCT-07:10 | 587.88 | 14.54 | 0.00 | 282.83 | 373.40 | 17.39 | 0.00 | 221.00 |
November | 317.83 | 0.66 | 0.62 | 01-NOV-07:40 | 496.48 | 13.95 | 0.00 | 243.50 | 328.94 | 17.06 | 0.00 | 163.33 |
December | 315.50 | 0.66 | 0.62 | 01-DEC-08:09 | 479.60 | 13.68 | 0.00 | 233.33 | 302.52 | 16.68 | 0.00 | 128.33 |
Annual Sum or Average | 4237.50 | 0.65 | 718.80 | 15.47 | 32.83 | 3542.83 | 422.39 | 18.41 | 136.17 | 2779.00 | ||
Minimum of Months | 303.83 | 0.63 | 0.62 | 479.60 | 13.62 | 0.00 | 233.33 | 302.52 | 16.54 | 0.00 | 128.33 | |
Maximum of Months | 406.00 | 0.66 | 0.62 | 988.15 | 17.24 | 17.17 | 363.33 | 543.91 | 21.11 | 80.33 | 330.83 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_4_DAYLCTRL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 319.33 | 0.65 | 0.62 | 01-JAN-08:39 | 1502.52 | 18.88 | 84.17 | 257.67 | 805.55 | 21.83 | 74.50 | 210.33 |
February | 303.83 | 0.65 | 0.62 | 01-FEB-08:30 | 1835.85 | 20.77 | 103.17 | 255.33 | 728.15 | 20.30 | 48.00 | 211.67 |
March | 364.50 | 0.64 | 0.62 | 01-MAR-07:00 | 1760.33 | 18.87 | 87.50 | 312.17 | 900.58 | 20.35 | 55.83 | 275.67 |
April | 379.83 | 0.65 | 0.62 | 01-APR-07:30 | 1997.48 | 17.75 | 84.50 | 324.83 | 1063.44 | 19.33 | 54.67 | 292.67 |
May | 406.00 | 0.64 | 0.62 | 01-MAY-06:00 | 1960.25 | 12.83 | 0.00 | 346.50 | 1012.96 | 16.74 | 0.00 | 310.00 |
June | 386.67 | 0.65 | 0.62 | 01-JUN-07:10 | 1948.16 | 12.95 | 0.00 | 333.17 | 791.42 | 16.65 | 0.00 | 292.83 |
July | 379.83 | 0.64 | 0.62 | 01-JUL-06:49 | 1466.17 | 13.65 | 3.50 | 330.00 | 663.34 | 16.97 | 0.00 | 274.83 |
August | 372.50 | 0.65 | 0.62 | 01-AUG-06:00 | 1365.32 | 15.59 | 51.83 | 316.00 | 681.24 | 16.89 | 4.67 | 259.00 |
September | 344.33 | 0.64 | 0.62 | 01-SEP-07:30 | 1503.56 | 18.06 | 77.00 | 294.67 | 762.58 | 19.79 | 52.17 | 247.33 |
October | 347.33 | 0.65 | 0.62 | 01-OCT-07:19 | 1789.19 | 18.49 | 86.33 | 286.33 | 917.90 | 21.27 | 72.17 | 252.17 |
November | 317.83 | 0.65 | 0.62 | 01-NOV-07:49 | 1576.00 | 19.33 | 85.00 | 261.33 | 786.96 | 20.56 | 55.00 | 223.67 |
December | 315.50 | 0.65 | 0.62 | 01-DEC-08:09 | 1379.87 | 19.54 | 87.67 | 259.50 | 714.33 | 20.94 | 59.33 | 217.00 |
Annual Sum or Average | 4237.50 | 0.65 | 1682.12 | 17.02 | 750.67 | 3577.50 | 823.73 | 19.16 | 476.33 | 3067.17 | ||
Minimum of Months | 303.83 | 0.64 | 0.62 | 1365.32 | 12.83 | 0.00 | 255.33 | 663.34 | 16.65 | 0.00 | 210.33 | |
Maximum of Months | 406.00 | 0.65 | 0.62 | 1997.48 | 20.77 | 103.17 | 346.50 | 1063.44 | 21.83 | 74.50 | 310.00 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_1_DAYLCTRL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 319.33 | 0.64 | 0.62 | 01-JAN-07:49 | 5285.35 | 34.68 | 296.50 | 285.00 | 1090.95 | 22.19 | 85.17 | 264.17 |
February | 303.83 | 0.64 | 0.62 | 01-FEB-07:49 | 3090.69 | 26.58 | 195.17 | 268.67 | 958.32 | 17.43 | 0.00 | 237.83 |
March | 364.50 | 0.64 | 0.62 | 01-MAR-07:40 | 1519.25 | 14.29 | 7.50 | 317.17 | 822.96 | 17.88 | 0.00 | 282.83 |
April | 379.83 | 0.65 | 0.62 | 01-APR-07:10 | 1014.09 | 13.05 | 0.00 | 323.67 | 604.14 | 16.89 | 0.00 | 285.33 |
May | 406.00 | 0.65 | 0.62 | 01-MAY-06:40 | 858.69 | 12.59 | 0.00 | 341.83 | 508.21 | 16.51 | 0.00 | 298.17 |
June | 386.67 | 0.65 | 0.62 | 01-JUN-06:00 | 853.13 | 12.16 | 0.00 | 327.67 | 492.16 | 16.00 | 0.00 | 278.33 |
July | 379.83 | 0.64 | 0.62 | 01-JUL-06:40 | 970.79 | 12.24 | 0.00 | 325.17 | 504.30 | 16.03 | 0.00 | 265.67 |
August | 372.50 | 0.65 | 0.62 | 01-AUG-06:49 | 1097.23 | 12.27 | 0.00 | 315.33 | 549.48 | 15.97 | 0.00 | 256.33 |
September | 344.33 | 0.64 | 0.62 | 01-SEP-06:00 | 1332.43 | 13.08 | 0.00 | 296.00 | 689.74 | 16.92 | 0.00 | 251.83 |
October | 347.33 | 0.65 | 0.62 | 01-OCT-06:00 | 2325.80 | 15.59 | 41.33 | 303.00 | 923.95 | 17.47 | 10.00 | 273.17 |
November | 317.83 | 0.64 | 0.62 | 01-NOV-07:10 | 7220.06 | 35.10 | 301.67 | 281.67 | 1137.07 | 21.44 | 74.33 | 268.00 |
December | 315.50 | 0.64 | 0.62 | 01-DEC-07:30 | 5565.55 | 34.89 | 296.00 | 281.50 | 1297.89 | 24.76 | 123.33 | 276.17 |
Annual Sum or Average | 4237.50 | 0.64 | 2439.90 | 18.98 | 1138.17 | 3666.67 | 776.67 | 18.12 | 292.83 | 3237.83 | ||
Minimum of Months | 303.83 | 0.64 | 0.62 | 853.13 | 12.16 | 0.00 | 268.67 | 492.16 | 15.97 | 0.00 | 237.83 | |
Maximum of Months | 406.00 | 0.65 | 0.62 | 7220.06 | 35.10 | 301.67 | 341.83 | 1297.89 | 24.76 | 123.33 | 298.17 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_2_DAYLCTRL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 319.33 | 0.66 | 0.62 | 01-JAN-07:49 | 1449.14 | 18.46 | 84.67 | 255.50 | 784.65 | 22.02 | 77.33 | 206.33 |
February | 303.83 | 0.65 | 0.62 | 01-FEB-07:49 | 1793.49 | 18.40 | 76.83 | 248.67 | 979.74 | 22.10 | 74.17 | 203.00 |
March | 364.50 | 0.64 | 0.62 | 01-MAR-07:30 | 1745.97 | 18.49 | 87.17 | 308.67 | 884.08 | 20.30 | 57.33 | 270.17 |
April | 379.83 | 0.65 | 0.62 | 01-APR-06:49 | 2097.88 | 17.27 | 85.00 | 318.50 | 1129.94 | 21.06 | 81.17 | 285.83 |
May | 406.00 | 0.64 | 0.62 | 01-MAY-06:10 | 2255.06 | 18.77 | 116.50 | 348.50 | 837.04 | 19.07 | 54.67 | 307.17 |
June | 386.67 | 0.65 | 0.62 | 01-JUN-06:40 | 1785.90 | 17.80 | 100.50 | 331.00 | 720.96 | 18.43 | 44.17 | 285.00 |
July | 379.83 | 0.64 | 0.62 | 01-JUL-06:10 | 1466.27 | 17.86 | 96.33 | 329.83 | 638.32 | 18.61 | 40.83 | 265.67 |
August | 372.50 | 0.65 | 0.62 | 01-AUG-06:19 | 1337.95 | 17.74 | 96.17 | 314.00 | 607.63 | 18.62 | 42.17 | 251.83 |
September | 344.33 | 0.65 | 0.62 | 01-SEP-06:49 | 1481.68 | 17.32 | 73.00 | 290.50 | 753.28 | 20.64 | 64.50 | 238.33 |
October | 347.33 | 0.65 | 0.62 | 01-OCT-06:49 | 1635.68 | 18.28 | 87.00 | 288.00 | 825.56 | 21.05 | 70.17 | 249.50 |
November | 317.83 | 0.65 | 0.62 | 01-NOV-07:10 | 1476.44 | 18.99 | 84.17 | 257.17 | 742.01 | 20.73 | 58.33 | 216.83 |
December | 315.50 | 0.65 | 0.62 | 01-DEC-07:30 | 1512.66 | 18.92 | 87.83 | 251.00 | 832.51 | 22.64 | 81.67 | 211.83 |
Annual Sum or Average | 4237.50 | 0.65 | 1681.93 | 18.17 | 1075.17 | 3541.33 | 809.84 | 20.34 | 746.50 | 2991.50 | ||
Minimum of Months | 303.83 | 0.64 | 0.62 | 1337.95 | 17.27 | 73.00 | 248.67 | 607.63 | 18.43 | 40.83 | 203.00 | |
Maximum of Months | 406.00 | 0.66 | 0.62 | 2255.06 | 18.99 | 116.50 | 348.50 | 1129.94 | 22.64 | 81.67 | 307.17 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_3_DAYLCTRL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 319.33 | 0.67 | 0.62 | 01-JAN-08:30 | 465.88 | 10.26 | 0.00 | 230.00 | 292.83 | 14.29 | 0.00 | 122.17 |
February | 303.83 | 0.66 | 0.62 | 01-FEB-08:20 | 538.65 | 11.16 | 0.00 | 238.50 | 336.74 | 15.19 | 0.00 | 157.00 |
March | 364.50 | 0.64 | 0.62 | 01-MAR-07:00 | 637.82 | 12.51 | 0.00 | 304.67 | 397.62 | 16.50 | 0.00 | 243.33 |
April | 379.83 | 0.65 | 0.62 | 01-APR-07:10 | 687.91 | 12.82 | 0.00 | 327.17 | 435.77 | 16.72 | 0.00 | 284.50 |
May | 406.00 | 0.64 | 0.62 | 01-MAY-06:19 | 827.94 | 13.03 | 1.17 | 361.00 | 491.79 | 17.06 | 1.17 | 325.83 |
June | 386.67 | 0.64 | 0.62 | 01-JUN-06:49 | 922.05 | 13.79 | 15.83 | 344.33 | 520.67 | 17.68 | 19.17 | 305.50 |
July | 379.83 | 0.64 | 0.62 | 01-JUL-06:19 | 945.39 | 12.47 | 0.00 | 337.50 | 495.98 | 18.05 | 29.83 | 283.00 |
August | 372.50 | 0.64 | 0.62 | 01-AUG-06:40 | 847.61 | 11.98 | 0.00 | 319.17 | 443.20 | 15.72 | 0.00 | 254.83 |
September | 344.33 | 0.65 | 0.62 | 01-SEP-06:00 | 730.25 | 12.12 | 0.00 | 291.67 | 409.26 | 15.93 | 0.00 | 223.33 |
October | 347.33 | 0.66 | 0.62 | 01-OCT-07:10 | 562.43 | 11.29 | 0.00 | 281.00 | 360.13 | 15.25 | 0.00 | 210.33 |
November | 317.83 | 0.66 | 0.62 | 01-NOV-07:40 | 474.14 | 10.60 | 0.00 | 239.17 | 317.41 | 14.82 | 0.00 | 150.17 |
December | 315.50 | 0.67 | 0.62 | 01-DEC-08:09 | 457.88 | 10.28 | 0.00 | 227.00 | 291.10 | 14.41 | 0.00 | 110.50 |
Annual Sum or Average | 4237.50 | 0.65 | 688.06 | 11.95 | 17.00 | 3501.17 | 405.78 | 16.06 | 50.17 | 2670.50 | ||
Minimum of Months | 303.83 | 0.64 | 0.62 | 457.88 | 10.26 | 0.00 | 227.00 | 291.10 | 14.29 | 0.00 | 110.50 | |
Maximum of Months | 406.00 | 0.67 | 0.62 | 945.39 | 13.79 | 15.83 | 361.00 | 520.67 | 18.05 | 29.83 | 325.83 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_4_DAYLCTRL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 319.33 | 0.66 | 0.62 | 01-JAN-08:39 | 1456.92 | 18.53 | 84.17 | 254.67 | 772.28 | 21.73 | 74.50 | 206.33 |
February | 303.83 | 0.65 | 0.62 | 01-FEB-08:30 | 1783.95 | 20.44 | 103.17 | 252.00 | 692.57 | 20.18 | 48.00 | 208.33 |
March | 364.50 | 0.64 | 0.62 | 01-MAR-07:00 | 1703.84 | 18.50 | 87.50 | 309.17 | 857.00 | 20.21 | 56.00 | 271.00 |
April | 379.83 | 0.65 | 0.62 | 01-APR-07:30 | 1932.86 | 17.37 | 84.50 | 322.67 | 1015.41 | 19.18 | 54.67 | 289.33 |
May | 406.00 | 0.65 | 0.62 | 01-MAY-07:10 | 1853.82 | 12.35 | 0.00 | 343.00 | 970.43 | 16.55 | 0.00 | 306.67 |
June | 386.67 | 0.65 | 0.62 | 01-JUN-07:10 | 1891.11 | 12.48 | 0.00 | 331.83 | 750.23 | 16.45 | 0.00 | 289.50 |
July | 379.83 | 0.64 | 0.62 | 01-JUL-06:49 | 1416.49 | 13.15 | 3.50 | 327.67 | 631.34 | 16.75 | 0.00 | 270.17 |
August | 372.50 | 0.65 | 0.62 | 01-AUG-07:10 | 1308.03 | 15.15 | 51.83 | 313.17 | 650.51 | 16.68 | 4.67 | 254.33 |
September | 344.33 | 0.64 | 0.62 | 01-SEP-07:30 | 1455.48 | 17.68 | 77.00 | 292.67 | 726.78 | 19.64 | 52.33 | 242.67 |
October | 347.33 | 0.65 | 0.62 | 01-OCT-07:30 | 1735.13 | 18.13 | 86.33 | 283.67 | 879.72 | 21.15 | 72.33 | 248.17 |
November | 317.83 | 0.65 | 0.62 | 01-NOV-07:49 | 1525.79 | 18.98 | 85.00 | 260.33 | 750.55 | 20.45 | 55.00 | 219.50 |
December | 315.50 | 0.65 | 0.62 | 01-DEC-08:20 | 1334.30 | 19.19 | 87.67 | 256.33 | 677.67 | 20.61 | 56.67 | 211.33 |
Annual Sum or Average | 4237.50 | 0.65 | 1623.93 | 16.62 | 750.67 | 3547.17 | 785.72 | 18.99 | 474.17 | 3017.33 | ||
Minimum of Months | 303.83 | 0.64 | 0.62 | 1308.03 | 12.35 | 0.00 | 252.00 | 631.34 | 16.45 | 0.00 | 206.33 | |
Maximum of Months | 406.00 | 0.66 | 0.62 | 1932.86 | 20.44 | 103.17 | 343.00 | 1015.41 | 21.73 | 74.50 | 306.67 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_1_DAYLCTRL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 319.33 | 0.64 | 0.62 | 01-JAN-07:49 | 5285.32 | 34.68 | 296.50 | 285.00 | 1090.87 | 22.19 | 85.17 | 264.17 |
February | 303.83 | 0.64 | 0.62 | 01-FEB-07:49 | 3090.63 | 26.58 | 195.17 | 268.67 | 958.26 | 17.43 | 0.00 | 237.83 |
March | 364.50 | 0.64 | 0.62 | 01-MAR-07:40 | 1519.20 | 14.30 | 7.50 | 317.17 | 822.90 | 17.88 | 0.00 | 282.83 |
April | 379.83 | 0.65 | 0.62 | 01-APR-07:10 | 1014.06 | 13.05 | 0.00 | 323.67 | 604.10 | 16.90 | 0.00 | 285.33 |
May | 406.00 | 0.65 | 0.62 | 01-MAY-06:40 | 858.66 | 12.59 | 0.00 | 341.83 | 508.18 | 16.51 | 0.00 | 298.17 |
June | 386.67 | 0.65 | 0.62 | 01-JUN-06:00 | 853.10 | 12.16 | 0.00 | 327.67 | 492.12 | 16.00 | 0.00 | 278.33 |
July | 379.83 | 0.64 | 0.62 | 01-JUL-06:40 | 970.73 | 12.25 | 0.00 | 325.17 | 504.25 | 16.03 | 0.00 | 265.67 |
August | 372.50 | 0.65 | 0.62 | 01-AUG-06:49 | 1097.16 | 12.27 | 0.00 | 315.33 | 549.43 | 15.97 | 0.00 | 256.33 |
September | 344.33 | 0.64 | 0.62 | 01-SEP-06:00 | 1332.36 | 13.09 | 0.00 | 296.00 | 689.68 | 16.92 | 0.00 | 251.83 |
October | 347.33 | 0.65 | 0.62 | 01-OCT-06:00 | 2325.74 | 15.59 | 41.33 | 303.00 | 923.89 | 17.47 | 10.00 | 273.17 |
November | 317.83 | 0.64 | 0.62 | 01-NOV-07:10 | 7220.03 | 35.10 | 301.67 | 281.67 | 1137.00 | 21.44 | 74.33 | 268.00 |
December | 315.50 | 0.64 | 0.62 | 01-DEC-07:30 | 5565.53 | 34.89 | 296.00 | 281.50 | 1297.82 | 24.76 | 123.33 | 276.17 |
Annual Sum or Average | 4237.50 | 0.64 | 2439.86 | 18.98 | 1138.17 | 3666.67 | 776.62 | 18.12 | 292.83 | 3237.83 | ||
Minimum of Months | 303.83 | 0.64 | 0.62 | 853.10 | 12.16 | 0.00 | 268.67 | 492.12 | 15.97 | 0.00 | 237.83 | |
Maximum of Months | 406.00 | 0.65 | 0.62 | 7220.03 | 35.10 | 301.67 | 341.83 | 1297.82 | 24.76 | 123.33 | 298.17 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_2_DAYLCTRL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 319.33 | 0.66 | 0.62 | 01-JAN-07:49 | 1449.13 | 18.46 | 84.67 | 255.50 | 784.62 | 22.02 | 77.33 | 206.33 |
February | 303.83 | 0.65 | 0.62 | 01-FEB-07:49 | 1793.48 | 18.40 | 76.83 | 248.67 | 979.70 | 22.10 | 74.17 | 203.00 |
March | 364.50 | 0.64 | 0.62 | 01-MAR-07:30 | 1745.95 | 18.49 | 87.17 | 308.67 | 884.04 | 20.31 | 57.33 | 270.17 |
April | 379.83 | 0.65 | 0.62 | 01-APR-06:49 | 2097.87 | 17.27 | 85.00 | 318.50 | 1129.90 | 21.06 | 81.17 | 285.83 |
May | 406.00 | 0.64 | 0.62 | 01-MAY-06:10 | 2255.04 | 18.77 | 116.50 | 348.50 | 837.00 | 19.07 | 54.67 | 307.17 |
June | 386.67 | 0.65 | 0.62 | 01-JUN-06:40 | 1785.87 | 17.80 | 100.50 | 331.00 | 720.91 | 18.44 | 44.17 | 285.00 |
July | 379.83 | 0.64 | 0.62 | 01-JUL-06:10 | 1466.22 | 17.87 | 96.33 | 329.83 | 638.27 | 18.62 | 40.83 | 265.67 |
August | 372.50 | 0.65 | 0.62 | 01-AUG-06:19 | 1337.89 | 17.74 | 96.17 | 314.00 | 607.57 | 18.62 | 42.17 | 251.83 |
September | 344.33 | 0.65 | 0.62 | 01-SEP-06:49 | 1481.64 | 17.32 | 73.00 | 290.50 | 753.23 | 20.64 | 64.50 | 238.33 |
October | 347.33 | 0.65 | 0.62 | 01-OCT-06:49 | 1635.67 | 18.28 | 87.00 | 288.00 | 825.53 | 21.05 | 70.17 | 249.50 |
November | 317.83 | 0.65 | 0.62 | 01-NOV-07:10 | 1476.45 | 18.99 | 84.17 | 257.17 | 741.98 | 20.73 | 58.33 | 216.83 |
December | 315.50 | 0.65 | 0.62 | 01-DEC-07:30 | 1512.66 | 18.93 | 87.83 | 251.00 | 832.47 | 22.64 | 81.67 | 211.83 |
Annual Sum or Average | 4237.50 | 0.65 | 1681.91 | 18.17 | 1075.17 | 3541.33 | 809.80 | 20.34 | 746.50 | 2991.50 | ||
Minimum of Months | 303.83 | 0.64 | 0.62 | 1337.89 | 17.27 | 73.00 | 248.67 | 607.57 | 18.44 | 40.83 | 203.00 | |
Maximum of Months | 406.00 | 0.66 | 0.62 | 2255.04 | 18.99 | 116.50 | 348.50 | 1129.90 | 22.64 | 81.67 | 307.17 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_3_DAYLCTRL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 319.33 | 0.67 | 0.62 | 01-JAN-08:30 | 465.88 | 10.26 | 0.00 | 230.00 | 292.82 | 14.29 | 0.00 | 122.17 |
February | 303.83 | 0.66 | 0.62 | 01-FEB-08:20 | 538.65 | 11.16 | 0.00 | 238.50 | 336.73 | 15.19 | 0.00 | 157.00 |
March | 364.50 | 0.64 | 0.62 | 01-MAR-07:00 | 637.81 | 12.51 | 0.00 | 304.67 | 397.60 | 16.51 | 0.00 | 243.33 |
April | 379.83 | 0.65 | 0.62 | 01-APR-07:10 | 687.91 | 12.83 | 0.00 | 327.17 | 435.75 | 16.72 | 0.00 | 284.50 |
May | 406.00 | 0.64 | 0.62 | 01-MAY-06:19 | 827.92 | 13.03 | 1.17 | 361.00 | 491.76 | 17.06 | 1.17 | 325.83 |
June | 386.67 | 0.64 | 0.62 | 01-JUN-06:49 | 922.03 | 13.79 | 15.83 | 344.33 | 520.63 | 17.68 | 19.17 | 305.50 |
July | 379.83 | 0.64 | 0.62 | 01-JUL-06:19 | 945.34 | 12.47 | 0.00 | 337.50 | 495.94 | 18.05 | 29.83 | 283.00 |
August | 372.50 | 0.64 | 0.62 | 01-AUG-06:40 | 847.56 | 11.99 | 0.00 | 319.17 | 443.17 | 15.72 | 0.00 | 254.83 |
September | 344.33 | 0.65 | 0.62 | 01-SEP-06:00 | 730.23 | 12.12 | 0.00 | 291.67 | 409.23 | 15.93 | 0.00 | 223.33 |
October | 347.33 | 0.66 | 0.62 | 01-OCT-07:10 | 562.43 | 11.29 | 0.00 | 281.00 | 360.11 | 15.25 | 0.00 | 210.33 |
November | 317.83 | 0.66 | 0.62 | 01-NOV-07:40 | 474.15 | 10.60 | 0.00 | 239.17 | 317.40 | 14.82 | 0.00 | 150.00 |
December | 315.50 | 0.67 | 0.62 | 01-DEC-08:09 | 457.88 | 10.28 | 0.00 | 227.00 | 291.09 | 14.42 | 0.00 | 110.50 |
Annual Sum or Average | 4237.50 | 0.65 | 688.05 | 11.95 | 17.00 | 3501.17 | 405.75 | 16.06 | 50.17 | 2670.33 | ||
Minimum of Months | 303.83 | 0.64 | 0.62 | 457.88 | 10.26 | 0.00 | 227.00 | 291.09 | 14.29 | 0.00 | 110.50 | |
Maximum of Months | 406.00 | 0.67 | 0.62 | 945.34 | 13.79 | 15.83 | 361.00 | 520.63 | 18.05 | 29.83 | 325.83 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_4_DAYLCTRL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 319.33 | 0.66 | 0.62 | 01-JAN-08:39 | 1456.91 | 18.53 | 84.17 | 254.67 | 772.25 | 21.73 | 74.50 | 206.33 |
February | 303.83 | 0.65 | 0.62 | 01-FEB-08:30 | 1783.94 | 20.44 | 103.17 | 252.00 | 692.53 | 20.18 | 48.00 | 208.33 |
March | 364.50 | 0.64 | 0.62 | 01-MAR-07:00 | 1703.82 | 18.50 | 87.50 | 309.17 | 856.96 | 20.21 | 56.00 | 271.00 |
April | 379.83 | 0.65 | 0.62 | 01-APR-07:30 | 1932.86 | 17.37 | 84.50 | 322.67 | 1015.38 | 19.18 | 54.67 | 289.33 |
May | 406.00 | 0.65 | 0.62 | 01-MAY-07:10 | 1853.80 | 12.36 | 0.00 | 343.00 | 970.38 | 16.55 | 0.00 | 306.67 |
June | 386.67 | 0.65 | 0.62 | 01-JUN-07:10 | 1891.08 | 12.48 | 0.00 | 331.83 | 750.19 | 16.45 | 0.00 | 289.50 |
July | 379.83 | 0.64 | 0.62 | 01-JUL-06:49 | 1416.43 | 13.15 | 3.50 | 327.67 | 631.29 | 16.75 | 0.00 | 270.17 |
August | 372.50 | 0.65 | 0.62 | 01-AUG-07:10 | 1307.97 | 15.16 | 51.83 | 313.17 | 650.45 | 16.68 | 4.67 | 254.33 |
September | 344.33 | 0.64 | 0.62 | 01-SEP-07:30 | 1455.44 | 17.68 | 77.00 | 292.67 | 726.73 | 19.64 | 52.33 | 242.50 |
October | 347.33 | 0.65 | 0.62 | 01-OCT-07:30 | 1735.12 | 18.13 | 86.33 | 283.67 | 879.69 | 21.16 | 72.33 | 248.17 |
November | 317.83 | 0.65 | 0.62 | 01-NOV-07:49 | 1525.79 | 18.98 | 85.00 | 260.33 | 750.51 | 20.45 | 55.00 | 219.50 |
December | 315.50 | 0.65 | 0.62 | 01-DEC-08:20 | 1334.30 | 19.19 | 87.67 | 256.33 | 677.64 | 20.61 | 56.67 | 211.33 |
Annual Sum or Average | 4237.50 | 0.65 | 1623.90 | 16.62 | 750.67 | 3547.17 | 785.67 | 19.00 | 474.17 | 3017.17 | ||
Minimum of Months | 303.83 | 0.64 | 0.62 | 1307.97 | 12.36 | 0.00 | 252.00 | 631.29 | 16.45 | 0.00 | 206.33 | |
Maximum of Months | 406.00 | 0.66 | 0.62 | 1932.86 | 20.44 | 103.17 | 343.00 | 1015.38 | 21.73 | 74.50 | 306.67 |
Report: CoilReportMonthly
For: CORE_BOTTOM VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.525260E+09 | 6309.14 | 02-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.378775E+09 | 6309.14 | 01-FEB-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 89104039.23 | 6309.14 | 01-MAR-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.106448E+09 | 6309.14 | 22-NOV-07:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.426510E+09 | 6309.14 | 01-DEC-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.152610E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.525260E+09 | 6309.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 3214085.64 | 4178.27 | 02-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 3214085.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 3214085.64 | 4178.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 13159617.44 | 6309.14 | 02-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 13159617.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 13159617.44 | 6309.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 6573193.56 | 4189.06 | 02-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 6573193.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 6573193.56 | 4189.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CORE_MID VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 17121781.03 | 7432.94 | 02-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 316484.07 | 1509.32 | 23-DEC-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 17438265.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 17121781.03 | 7432.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 24658297.31 | 4902.76 | 02-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 201718.15 | 907.64 | 11-FEB-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 1214085.55 | 3375.15 | 23-DEC-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 26074101.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 24658297.31 | 4902.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 50676684.21 | 7441.59 | 02-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 3305647.21 | 3723.50 | 23-DEC-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 53982331.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 50676684.21 | 7441.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 45596015.15 | 4912.33 | 02-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 1427176.31 | 1377.68 | 11-FEB-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 5226025.88 | 3650.55 | 23-DEC-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 52249217.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 45596015.15 | 4912.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CORE_TOP VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.153340E+09 | 26295.84 | 02-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 5335937.78 | 10247.85 | 23-DEC-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.158676E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.153340E+09 | 26295.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.251069E+09 | 10490.86 | 02-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 42054919.92 | 10490.86 | 01-FEB-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 192986.95 | 490.36 | 25-NOV-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 86675966.27 | 10490.86 | 04-DEC-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.379993E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.251069E+09 | 10490.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.213069E+09 | 6855.36 | 02-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 33914703.85 | 6855.36 | 01-FEB-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 1988102.65 | 3528.00 | 27-NOV-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 87341250.12 | 6855.36 | 04-DEC-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.336313E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.213069E+09 | 6855.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.459935E+09 | 10498.13 | 02-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 78426467.14 | 10498.13 | 01-FEB-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 5649336.45 | 5155.35 | 27-NOV-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.186908E+09 | 10498.13 | 04-DEC-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.730919E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.459935E+09 | 10498.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.350101E+09 | 6863.97 | 02-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 73296005.52 | 6863.97 | 01-FEB-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 6937185.19 | 4135.35 | 27-NOV-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.160374E+09 | 6863.97 | 04-DEC-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.590708E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.350101E+09 | 6863.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_BOT HEATING COIL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 99403884.23 | 2870.87 | 03-JAN-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 1367454.20 | 546.62 | 02-FEB-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 16962498.58 | 1784.60 | 23-DEC-06:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.117734E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 99403884.23 | 2870.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_MID HEATING COIL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.276996E+09 | 4114.92 | 03-JAN-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 14429366.03 | 1503.96 | 02-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 57469462.31 | 3091.29 | 23-DEC-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.348894E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.276996E+09 | 4114.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_TOP HEATING COIL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.540123E+09 | 4155.39 | 02-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 87104929.51 | 4155.39 | 02-FEB-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 943583.59 | 699.11 | 27-NOV-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.159663E+09 | 4155.39 | 20-DEC-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.787835E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.540123E+09 | 4155.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_BOT COOLING COIL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.214437E+11 | 0.189949E+11 | 37071.97 | 12-JAN-15:00 | 37071.97 | 0.00 |
February | 0.00 | 0.00 | 0.303701E+11 | 0.274589E+11 | 50052.01 | 22-FEB-16:10 | 50052.01 | 0.00 |
March | 0.00 | 0.00 | 0.548301E+11 | 0.510694E+11 | 73543.35 | 29-MAR-11:20 | 54019.59 | 0.00 |
April | 0.00 | 0.00 | 0.758726E+11 | 0.709172E+11 | 97749.32 | 27-APR-04:03 | 73655.54 | 0.00 |
May | 0.00 | 0.00 | 0.109851E+12 | 0.919529E+11 | 130224.22 | 24-MAY-04:03 | 71047.15 | 0.00 |
June | 0.00 | 0.00 | 0.124963E+12 | 0.934786E+11 | 133930.22 | 27-JUN-04:02 | 77701.74 | 0.00 |
July | 0.00 | 0.00 | 0.136881E+12 | 0.866835E+11 | 136871.51 | 20-JUL-04:02 | 71815.05 | 0.00 |
August | 0.00 | 0.00 | 0.140138E+12 | 0.863534E+11 | 134051.79 | 11-AUG-04:03 | 75059.84 | 0.00 |
September | 0.00 | 0.00 | 0.113225E+12 | 0.753738E+11 | 132947.54 | 06-SEP-04:02 | 79548.79 | 0.00 |
October | 0.00 | 0.00 | 0.783232E+11 | 0.669623E+11 | 122168.65 | 04-OCT-04:02 | 84093.27 | 0.00 |
November | 0.00 | 0.00 | 0.490539E+11 | 0.455609E+11 | 63228.20 | 06-NOV-14:00 | 58366.04 | 0.00 |
December | 0.00 | 0.00 | 0.268716E+11 | 0.245897E+11 | 43051.65 | 01-DEC-14:00 | 43051.65 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.961823E+12 | 0.739396E+12 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.214437E+11 | 0.189949E+11 | 37071.97 | 37071.97 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.140138E+12 | 0.934786E+11 | 136871.51 | 84093.27 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_MID COOLING COIL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.148108E+11 | 0.123760E+11 | 29240.48 | 12-JAN-15:10 | 29240.48 | 0.00 |
February | 0.00 | 0.00 | 0.238994E+11 | 0.209076E+11 | 43629.08 | 22-FEB-15:30 | 43629.08 | 0.00 |
March | 0.00 | 0.00 | 0.476477E+11 | 0.441943E+11 | 63063.04 | 28-MAR-16:00 | 63063.04 | 0.00 |
April | 0.00 | 0.00 | 0.696989E+11 | 0.658359E+11 | 97424.45 | 27-APR-04:03 | 72564.56 | 0.00 |
May | 0.00 | 0.00 | 0.100031E+12 | 0.847608E+11 | 122216.78 | 24-MAY-04:03 | 65181.13 | 0.00 |
June | 0.00 | 0.00 | 0.110733E+12 | 0.833339E+11 | 123168.01 | 27-JUN-04:02 | 67284.94 | 0.00 |
July | 0.00 | 0.00 | 0.118027E+12 | 0.738674E+11 | 125238.09 | 20-JUL-04:02 | 60875.93 | 0.00 |
August | 0.00 | 0.00 | 0.116274E+12 | 0.702188E+11 | 122711.50 | 19-AUG-05:03 | 66394.25 | 0.00 |
September | 0.00 | 0.00 | 0.926074E+11 | 0.604071E+11 | 121959.03 | 06-SEP-04:02 | 65149.38 | 0.00 |
October | 0.00 | 0.00 | 0.622642E+11 | 0.530437E+11 | 93532.43 | 04-OCT-05:03 | 63701.84 | 0.00 |
November | 0.00 | 0.00 | 0.372632E+11 | 0.338776E+11 | 53399.52 | 06-NOV-14:00 | 48504.27 | 0.00 |
December | 0.00 | 0.00 | 0.186372E+11 | 0.160896E+11 | 33785.65 | 01-DEC-15:10 | 33785.65 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.811894E+12 | 0.618913E+12 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.148108E+11 | 0.123760E+11 | 29240.48 | 29240.48 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.118027E+12 | 0.847608E+11 | 125238.09 | 72564.56 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_TOP COOLING COIL
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.151230E+11 | 0.122352E+11 | 30782.03 | 12-JAN-15:00 | 30782.03 | 0.00 |
February | 0.00 | 0.00 | 0.245046E+11 | 0.209330E+11 | 50835.02 | 22-FEB-15:00 | 50835.02 | 0.00 |
March | 0.00 | 0.00 | 0.512685E+11 | 0.468860E+11 | 76817.55 | 28-MAR-16:00 | 76817.55 | 0.00 |
April | 0.00 | 0.00 | 0.780304E+11 | 0.737287E+11 | 113840.01 | 16-APR-16:02 | 101838.98 | 0.00 |
May | 0.00 | 0.00 | 0.112533E+12 | 0.966106E+11 | 139829.20 | 24-MAY-04:03 | 72965.33 | 0.00 |
June | 0.00 | 0.00 | 0.123671E+12 | 0.953894E+11 | 144267.98 | 27-JUN-04:02 | 80364.29 | 0.00 |
July | 0.00 | 0.00 | 0.129330E+12 | 0.834788E+11 | 147019.23 | 26-JUL-04:03 | 70289.89 | 0.00 |
August | 0.00 | 0.00 | 0.124067E+12 | 0.773248E+11 | 143868.36 | 31-AUG-04:02 | 81393.03 | 0.00 |
September | 0.00 | 0.00 | 0.973066E+11 | 0.648619E+11 | 142359.15 | 01-SEP-04:02 | 79740.02 | 0.00 |
October | 0.00 | 0.00 | 0.653151E+11 | 0.557848E+11 | 88578.49 | 04-OCT-12:40 | 69259.40 | 0.00 |
November | 0.00 | 0.00 | 0.378157E+11 | 0.337373E+11 | 58822.91 | 09-NOV-13:30 | 54797.67 | 0.00 |
December | 0.00 | 0.00 | 0.181577E+11 | 0.149818E+11 | 36550.77 | 01-DEC-14:50 | 36550.77 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.877123E+12 | 0.675952E+12 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.151230E+11 | 0.122352E+11 | 30782.03 | 30782.03 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.129330E+12 | 0.966106E+11 | 147019.23 | 101838.98 | 0.00 |
Report: PlantLoopDemandReportMonthly
For: SWHSYS1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 1496.91 | 5154.49 | 17-JAN-12:08 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 1477.39 | 5110.31 | 02-FEB-12:10 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 1476.80 | 4873.17 | 01-MAR-12:20 |
April | 0.00 | 0.00 | 01-APR-00:10 | 1255.11 | 4448.44 | 03-APR-11:15 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 1167.01 | 4023.24 | 01-MAY-11:06 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 1087.80 | 3570.16 | 02-JUN-11:18 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 962.10 | 3325.72 | 03-JUL-11:10 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 1083.99 | 3518.60 | 31-AUG-11:15 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 1107.83 | 3903.46 | 28-SEP-11:10 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 1233.02 | 4403.37 | 31-OCT-11:15 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 1381.37 | 4812.47 | 30-NOV-13:00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 1420.78 | 5063.98 | 29-DEC-12:30 |
Annual Sum or Average | 0.00 | 1261.34 | ||||
Minimum of Months | 0.00 | 0.00 | 962.10 | 3325.72 | ||
Maximum of Months | 0.00 | 0.00 | 1496.91 | 5154.49 |
Report: FanReportMonthly
For: PACU_VAV_BOT FAN
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.209950E+10 | 0.31 | 3935.99 | 12-JAN-06:03 | 0.94 |
February | 0.251768E+10 | 0.36 | 5340.18 | 21-FEB-16:30 | 1.12 |
March | 0.398992E+10 | 0.44 | 6283.29 | 13-MAR-10:30 | 1.23 |
April | 0.497266E+10 | 0.51 | 10730.17 | 28-APR-04:02 | 1.74 |
May | 0.637326E+10 | 0.59 | 11538.89 | 01-MAY-06:03 | 1.82 |
June | 0.655354E+10 | 0.62 | 11538.89 | 03-JUN-06:03 | 1.81 |
July | 0.630381E+10 | 0.59 | 11538.89 | 01-JUL-04:02 | 1.81 |
August | 0.672841E+10 | 0.61 | 11538.89 | 01-AUG-04:02 | 1.81 |
September | 0.579274E+10 | 0.56 | 11538.89 | 01-SEP-04:02 | 1.81 |
October | 0.484527E+10 | 0.49 | 11193.27 | 11-OCT-04:02 | 1.78 |
November | 0.357478E+10 | 0.42 | 6056.78 | 06-NOV-17:00 | 1.21 |
December | 0.251104E+10 | 0.34 | 4307.07 | 01-DEC-15:40 | 0.99 |
Annual Sum or Average | 0.562626E+11 | 0.49 | |||
Minimum of Months | 0.209950E+10 | 0.31 | 3935.99 | 0.94 | |
Maximum of Months | 0.672841E+10 | 0.62 | 11538.89 | 1.82 |
Report: FanReportMonthly
For: PACU_VAV_MID FAN
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.149838E+10 | 0.29 | 2474.17 | 12-JAN-15:10 | 0.78 |
February | 0.190699E+10 | 0.34 | 4452.17 | 22-FEB-15:40 | 1.09 |
March | 0.357496E+10 | 0.44 | 6727.91 | 13-MAR-16:00 | 1.40 |
April | 0.516213E+10 | 0.55 | 10231.17 | 17-APR-04:02 | 1.82 |
May | 0.656188E+10 | 0.64 | 10231.17 | 02-MAY-04:02 | 1.82 |
June | 0.653011E+10 | 0.66 | 10231.17 | 05-JUN-05:03 | 1.82 |
July | 0.584769E+10 | 0.59 | 10231.17 | 01-JUL-04:02 | 1.82 |
August | 0.585390E+10 | 0.59 | 10231.17 | 01-AUG-04:02 | 1.82 |
September | 0.475599E+10 | 0.52 | 10231.17 | 01-SEP-04:02 | 1.82 |
October | 0.385822E+10 | 0.46 | 8839.83 | 02-OCT-04:02 | 1.66 |
November | 0.258437E+10 | 0.37 | 5146.72 | 13-NOV-16:00 | 1.19 |
December | 0.168453E+10 | 0.30 | 3236.08 | 01-DEC-15:30 | 0.90 |
Annual Sum or Average | 0.498191E+11 | 0.48 | |||
Minimum of Months | 0.149838E+10 | 0.29 | 2474.17 | 0.78 | |
Maximum of Months | 0.656188E+10 | 0.66 | 10231.17 | 1.82 |
Report: FanReportMonthly
For: PACU_VAV_TOP FAN
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.143870E+10 | 0.28 | 2373.27 | 02-JAN-06:01 | 0.68 |
February | 0.171628E+10 | 0.31 | 4076.09 | 22-FEB-15:00 | 0.91 |
March | 0.330695E+10 | 0.39 | 7251.71 | 13-MAR-15:50 | 1.29 |
April | 0.518163E+10 | 0.50 | 11521.65 | 17-APR-04:02 | 1.73 |
May | 0.667444E+10 | 0.59 | 12413.10 | 17-MAY-04:02 | 1.81 |
June | 0.663095E+10 | 0.60 | 12413.10 | 15-JUN-04:02 | 1.81 |
July | 0.564316E+10 | 0.54 | 12413.10 | 12-JUL-04:02 | 1.81 |
August | 0.545532E+10 | 0.52 | 12413.10 | 01-AUG-04:02 | 1.81 |
September | 0.442299E+10 | 0.46 | 11930.47 | 25-SEP-04:02 | 1.77 |
October | 0.360227E+10 | 0.40 | 6931.11 | 10-OCT-14:50 | 1.25 |
November | 0.233090E+10 | 0.33 | 4678.61 | 09-NOV-15:30 | 0.99 |
December | 0.151622E+10 | 0.28 | 2599.28 | 01-DEC-15:00 | 0.72 |
Annual Sum or Average | 0.479198E+11 | 0.43 | |||
Minimum of Months | 0.143870E+10 | 0.28 | 2373.27 | 0.68 | |
Maximum of Months | 0.667444E+10 | 0.60 | 12413.10 | 1.81 |
Report: PumpReportMonthly
For: SWHSYS1 PUMP
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportPUMP ELECTRICITY ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRICITY RATE {Maximum} [W] | PUMP ELECTRICITY RATE {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
January | 1312252.65 | 393675.80 | 0.73 | 01-JAN-06:10 | 0.22 | 0.22 | 56.83 | 0.05 |
February | 1186778.30 | 356033.49 | 0.73 | 01-FEB-06:02 | 0.22 | 0.22 | 57.15 | 0.05 |
March | 1343621.24 | 403086.37 | 0.73 | 01-MAR-06:03 | 0.22 | 0.22 | 56.39 | 0.05 |
April | 1267813.82 | 380344.15 | 0.73 | 01-APR-05:03 | 0.22 | 0.22 | 57.42 | 0.05 |
May | 1327936.95 | 398381.08 | 0.73 | 01-MAY-05:05 | 0.22 | 0.22 | 57.19 | 0.05 |
June | 1296568.36 | 388970.51 | 0.73 | 01-JUN-05:03 | 0.22 | 0.22 | 57.48 | 0.05 |
July | 1299182.41 | 389754.72 | 0.73 | 01-JUL-05:05 | 0.22 | 0.22 | 57.35 | 0.05 |
August | 1343621.24 | 403086.37 | 0.73 | 01-AUG-05:05 | 0.22 | 0.22 | 56.97 | 0.05 |
September | 1267813.82 | 380344.15 | 0.73 | 01-SEP-05:03 | 0.22 | 0.22 | 57.22 | 0.05 |
October | 1312252.65 | 393675.80 | 0.73 | 01-OCT-05:10 | 0.22 | 0.22 | 57.47 | 0.05 |
November | 1278270.02 | 383481.00 | 0.73 | 01-NOV-05:03 | 0.22 | 0.22 | 57.40 | 0.05 |
December | 1299182.41 | 389754.72 | 0.73 | 01-DEC-06:03 | 0.22 | 0.22 | 56.09 | 0.05 |
Annual Sum or Average | 15535293.87 | 4660588.16 | ||||||
Minimum of Months | 1186778.30 | 356033.49 | 0.73 | 0.22 | 0.22 | 56.09 | 0.05 | |
Maximum of Months | 1343621.24 | 403086.37 | 0.73 | 0.22 | 0.22 | 57.48 | 0.05 |
Report: CondLoopDemandReportMonthly
For: SWHSYS1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 57.03 | 57.03 | 1496.91 | 5154.49 | 17-JAN-12:08 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 57.47 | 57.47 | 1477.39 | 5110.31 | 02-FEB-12:10 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 56.73 | 56.73 | 1476.80 | 4873.17 | 01-MAR-12:20 |
April | 0.00 | 0.00 | 01-APR-00:10 | 57.70 | 57.70 | 1255.11 | 4448.44 | 03-APR-11:15 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 57.31 | 57.31 | 1167.01 | 4023.24 | 01-MAY-11:06 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 57.63 | 57.63 | 1087.80 | 3570.16 | 02-JUN-11:18 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 57.44 | 57.44 | 962.10 | 3325.72 | 03-JUL-11:10 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 57.07 | 57.07 | 1083.99 | 3518.60 | 31-AUG-11:15 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 57.36 | 57.36 | 1107.83 | 3903.46 | 28-SEP-11:10 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 57.05 | 57.05 | 1233.02 | 4403.37 | 31-OCT-11:15 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 57.67 | 57.67 | 1381.37 | 4812.47 | 30-NOV-13:00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 56.40 | 56.40 | 1420.78 | 5063.98 | 29-DEC-12:30 |
Annual Sum or Average | 0.00 | 1261.34 | ||||||
Minimum of Months | 0.00 | 0.00 | 56.40 | 56.40 | 962.10 | 3325.72 | ||
Maximum of Months | 0.00 | 0.00 | 57.70 | 57.70 | 1496.91 | 5154.49 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PACU_VAV_BOT
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.819694E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.104885E+11 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.181578E+11 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.269019E+11 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.400145E+11 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.438263E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.434504E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.434849E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.352473E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.253198E+11 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.158864E+11 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.975452E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.320729E+12 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.819694E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.438263E+11 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PACU_VAV_MID
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.555724E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.796319E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.158644E+11 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.252634E+11 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.369950E+11 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.392782E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.376439E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.360998E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.286693E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.202374E+11 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.120046E+11 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.655068E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.272127E+12 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.555724E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.392782E+11 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PACU_VAV_TOP
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.690324E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.822097E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.166802E+11 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.279096E+11 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.411606E+11 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.434634E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.406059E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.378376E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.297138E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.209944E+11 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.120501E+11 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.683367E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.292373E+12 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.683367E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.434634E+11 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PACU_VAV_BOT
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.209950E+10 | 0.214437E+11 | 0.647611E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.251768E+10 | 0.303701E+11 | 0.380142E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.398992E+10 | 0.548301E+11 | 89104039.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.497266E+10 | 0.758726E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.637326E+10 | 0.109851E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.655354E+10 | 0.124963E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.630381E+10 | 0.136881E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.672841E+10 | 0.140138E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.579274E+10 | 0.113225E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.484527E+10 | 0.783232E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.357478E+10 | 0.490539E+11 | 0.106448E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.251104E+10 | 0.268716E+11 | 0.443473E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.562626E+11 | 0.961823E+12 | 0.166678E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.209950E+10 | 0.214437E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.672841E+10 | 0.140138E+12 | 0.647611E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PACU_VAV_MID
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.149838E+10 | 0.148108E+11 | 0.415048E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.190699E+10 | 0.238994E+11 | 16058260.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.357496E+10 | 0.476477E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.516213E+10 | 0.696989E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.656188E+10 | 0.100031E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.653011E+10 | 0.110733E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.584769E+10 | 0.118027E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.585390E+10 | 0.116274E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.475599E+10 | 0.926074E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.385822E+10 | 0.622642E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.258437E+10 | 0.372632E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.168453E+10 | 0.186372E+11 | 67531705.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.498191E+11 | 0.811894E+12 | 0.498638E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.149838E+10 | 0.148108E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.656188E+10 | 0.118027E+12 | 0.415048E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PACU_VAV_TOP
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.143870E+10 | 0.151230E+11 | 0.196764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.171628E+10 | 0.245046E+11 | 0.314797E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.330695E+10 | 0.512685E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.518163E+10 | 0.780304E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.667444E+10 | 0.112533E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.663095E+10 | 0.123671E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.564316E+10 | 0.129330E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.545532E+10 | 0.124067E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.442299E+10 | 0.973066E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.360227E+10 | 0.653151E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.233090E+10 | 0.378157E+11 | 15711194.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.151622E+10 | 0.181577E+11 | 0.686298E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.479198E+11 | 0.877123E+12 | 0.298444E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.143870E+10 | 0.151230E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.667444E+10 | 0.129330E+12 | 0.196764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PACU_VAV_BOT
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.209950E+10 | 0.00 | 0.00 | 0.00 | 0.554924E+10 | 0.548207E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.251768E+10 | 0.00 | 0.00 | 0.00 | 0.759207E+10 | 0.378775E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.398992E+10 | 0.00 | 0.00 | 0.00 | 0.140787E+11 | 89104039.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.497266E+10 | 0.00 | 0.00 | 0.00 | 0.219292E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.637326E+10 | 0.00 | 0.00 | 0.00 | 0.336412E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.655354E+10 | 0.00 | 0.00 | 0.00 | 0.372728E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.630381E+10 | 0.00 | 0.00 | 0.00 | 0.371466E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.672841E+10 | 0.00 | 0.00 | 0.00 | 0.367565E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.579274E+10 | 0.00 | 0.00 | 0.00 | 0.294546E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.484527E+10 | 0.00 | 0.00 | 0.00 | 0.204745E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.357478E+10 | 0.00 | 0.00 | 0.00 | 0.122052E+11 | 0.106448E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.251104E+10 | 0.00 | 0.00 | 0.00 | 0.681697E+10 | 0.426510E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.562626E+11 | 0.00 | 0.00 | 0.00 | 0.262918E+12 | 0.154904E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.209950E+10 | 0.00 | 0.00 | 0.00 | 0.554924E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.672841E+10 | 0.00 | 0.00 | 0.00 | 0.372728E+11 | 0.548207E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PACU_VAV_MID
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.149838E+10 | 0.00 | 0.00 | 0.00 | 0.392081E+10 | 0.138053E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.190699E+10 | 0.00 | 0.00 | 0.00 | 0.605458E+10 | 1628894.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.357496E+10 | 0.00 | 0.00 | 0.00 | 0.122894E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.516213E+10 | 0.00 | 0.00 | 0.00 | 0.201013E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.656188E+10 | 0.00 | 0.00 | 0.00 | 0.304331E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.653011E+10 | 0.00 | 0.00 | 0.00 | 0.327481E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.584769E+10 | 0.00 | 0.00 | 0.00 | 0.317962E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.585390E+10 | 0.00 | 0.00 | 0.00 | 0.302459E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.475599E+10 | 0.00 | 0.00 | 0.00 | 0.239133E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.385822E+10 | 0.00 | 0.00 | 0.00 | 0.163792E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.258437E+10 | 0.00 | 0.00 | 0.00 | 0.942028E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.168453E+10 | 0.00 | 0.00 | 0.00 | 0.485609E+10 | 10062242.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.498191E+11 | 0.00 | 0.00 | 0.00 | 0.222158E+12 | 0.149744E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.149838E+10 | 0.00 | 0.00 | 0.00 | 0.392081E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.656188E+10 | 0.00 | 0.00 | 0.00 | 0.327481E+11 | 0.138053E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PACU_VAV_TOP
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.143870E+10 | 0.00 | 0.00 | 0.00 | 0.403703E+10 | 0.142751E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.171628E+10 | 0.00 | 0.00 | 0.00 | 0.627700E+10 | 0.227692E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.330695E+10 | 0.00 | 0.00 | 0.00 | 0.133733E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.518163E+10 | 0.00 | 0.00 | 0.00 | 0.227280E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.667444E+10 | 0.00 | 0.00 | 0.00 | 0.344861E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.663095E+10 | 0.00 | 0.00 | 0.00 | 0.368324E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.564316E+10 | 0.00 | 0.00 | 0.00 | 0.349628E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.545532E+10 | 0.00 | 0.00 | 0.00 | 0.323823E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.442299E+10 | 0.00 | 0.00 | 0.00 | 0.252908E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.360227E+10 | 0.00 | 0.00 | 0.00 | 0.173921E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.233090E+10 | 0.00 | 0.00 | 0.00 | 0.970441E+10 | 14767611.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.151622E+10 | 0.00 | 0.00 | 0.00 | 0.479082E+10 | 0.526634E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.479198E+11 | 0.00 | 0.00 | 0.00 | 0.242257E+12 | 0.219661E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.143870E+10 | 0.00 | 0.00 | 0.00 | 0.403703E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.667444E+10 | 0.00 | 0.00 | 0.00 | 0.368324E+11 | 0.142751E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.945783E+09 | 626952.15 | 0.00 | 38216532.90 | 111064.68 | 0.00 | 0.777538E+10 | 0.00 | 0.40 |
February | 0.479092E+09 | 32775898.80 | 0.00 | 36546979.38 | 13592670.45 | 0.00 | 0.472481E+10 | 0.00 | 0.42 |
March | 0.247018E+09 | 0.919911E+09 | 0.00 | 31569302.67 | 0.215912E+09 | 0.00 | 0.223184E+10 | 0.00 | 0.42 |
April | 29594342.71 | 0.375435E+10 | 0.00 | 5820265.27 | 0.100834E+10 | 0.00 | 0.123352E+09 | 0.00 | 0.36 |
May | 1345343.88 | 0.105876E+11 | 0.00 | 128373.39 | 0.251600E+10 | 0.00 | 3321631.56 | 0.00 | 0.37 |
June | 0.00 | 0.150482E+11 | 0.00 | 0.00 | 0.386822E+10 | 0.00 | 0.00 | 0.00 | 0.37 |
July | 0.00 | 0.181122E+11 | 0.00 | 0.00 | 0.709357E+10 | 0.00 | 0.00 | 0.00 | 0.37 |
August | 0.00 | 0.203383E+11 | 0.00 | 0.00 | 0.470855E+10 | 0.00 | 0.00 | 0.00 | 0.36 |
September | 0.00 | 0.144545E+11 | 0.00 | 0.00 | 0.339121E+10 | 0.00 | 0.00 | 0.00 | 0.34 |
October | 59261902.53 | 0.383423E+10 | 0.00 | 9371886.89 | 0.907729E+09 | 0.00 | 0.347176E+09 | 0.00 | 0.36 |
November | 0.356278E+09 | 0.164298E+09 | 0.00 | 39309683.37 | 0.124339E+09 | 0.00 | 0.297081E+10 | 0.00 | 0.39 |
December | 0.779187E+09 | 688079.06 | 0.00 | 40660807.26 | 6854006.81 | 0.00 | 0.732472E+10 | 0.00 | 0.41 |
Annual Sum or Average | 0.289756E+10 | 0.872477E+11 | 0.00 | 0.201624E+09 | 0.238544E+11 | 0.00 | 0.255014E+11 | 0.00 | 0.38 |
Minimum of Months | 0.00 | 626952.15 | 0.00 | 0.00 | 111064.68 | 0.00 | 0.00 | 0.00 | 0.34 |
Maximum of Months | 0.945783E+09 | 0.203383E+11 | 0.00 | 40660807.26 | 0.709357E+10 | 0.00 | 0.777538E+10 | 0.00 | 0.42 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.363763E+10 | 0.00 | 0.00 | 9416052.66 | 3071050.81 | 0.00 | 0.265647E+10 | 0.00 | 0.29 |
February | 0.128835E+10 | 28160042.73 | 0.00 | 15843420.62 | 19476945.63 | 0.00 | 0.239473E+10 | 0.00 | 0.31 |
March | 0.257050E+09 | 0.650477E+09 | 0.00 | 19853629.62 | 0.215021E+09 | 0.00 | 0.155814E+10 | 0.00 | 0.32 |
April | 53441743.74 | 0.293014E+10 | 0.00 | 5034917.34 | 0.102596E+10 | 0.00 | 0.100077E+09 | 0.00 | 0.32 |
May | 1371755.64 | 0.917193E+10 | 0.00 | 75768.91 | 0.258898E+10 | 0.00 | 1059629.42 | 0.00 | 0.35 |
June | 0.00 | 0.134879E+11 | 0.00 | 0.00 | 0.381587E+10 | 0.00 | 0.00 | 0.00 | 0.35 |
July | 0.00 | 0.168902E+11 | 0.00 | 0.00 | 0.627770E+10 | 0.00 | 0.00 | 0.00 | 0.35 |
August | 0.00 | 0.190683E+11 | 0.00 | 0.00 | 0.395078E+10 | 0.00 | 0.00 | 0.00 | 0.34 |
September | 0.00 | 0.132563E+11 | 0.00 | 0.00 | 0.292096E+10 | 0.00 | 0.00 | 0.00 | 0.32 |
October | 84897928.15 | 0.330129E+10 | 0.00 | 5852015.60 | 0.715131E+09 | 0.00 | 0.181773E+09 | 0.00 | 0.31 |
November | 0.448881E+09 | 0.138060E+09 | 0.00 | 21989508.90 | 0.112889E+09 | 0.00 | 0.186980E+10 | 0.00 | 0.31 |
December | 0.260354E+10 | 0.00 | 0.00 | 13294916.83 | 18337882.33 | 0.00 | 0.306613E+10 | 0.00 | 0.30 |
Annual Sum or Average | 0.837517E+10 | 0.789228E+11 | 0.00 | 91360230.49 | 0.216642E+11 | 0.00 | 0.118282E+11 | 0.00 | 0.32 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 3071050.81 | 0.00 | 0.00 | 0.00 | 0.29 |
Maximum of Months | 0.363763E+10 | 0.190683E+11 | 0.00 | 21989508.90 | 0.627770E+10 | 0.00 | 0.306613E+10 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.414451E+10 | 0.00 | 0.00 | 3838044.82 | 3701282.61 | 82989550.16 | 0.108888E+10 | 0.00 | 0.28 |
February | 0.161232E+10 | 9839617.53 | 0.00 | 9862653.69 | 53067495.76 | 0.00 | 0.135256E+10 | 0.00 | 0.29 |
March | 0.308207E+09 | 0.626638E+09 | 0.00 | 14952675.20 | 0.261468E+09 | 0.00 | 0.107597E+10 | 0.00 | 0.31 |
April | 22464329.88 | 0.274506E+10 | 0.00 | 6116881.00 | 0.992360E+09 | 0.00 | 0.108129E+09 | 0.00 | 0.31 |
May | 99836.26 | 0.881557E+10 | 0.00 | 0.00 | 0.261998E+10 | 0.00 | 0.00 | 0.00 | 0.35 |
June | 0.00 | 0.130879E+11 | 0.00 | 0.00 | 0.411691E+10 | 0.00 | 0.00 | 0.00 | 0.36 |
July | 0.00 | 0.164212E+11 | 0.00 | 0.00 | 0.678187E+10 | 0.00 | 0.00 | 0.00 | 0.36 |
August | 0.00 | 0.185267E+11 | 0.00 | 0.00 | 0.414588E+10 | 0.00 | 0.00 | 0.00 | 0.34 |
September | 0.00 | 0.126535E+11 | 0.00 | 0.00 | 0.321752E+10 | 0.00 | 0.00 | 0.00 | 0.32 |
October | 52187385.36 | 0.320369E+10 | 0.00 | 2688894.03 | 0.703976E+09 | 0.00 | 42660911.15 | 0.00 | 0.30 |
November | 0.695731E+09 | 0.129071E+09 | 0.00 | 13967107.16 | 0.142888E+09 | 0.00 | 0.963512E+09 | 0.00 | 0.29 |
December | 0.314716E+10 | 0.00 | 0.00 | 6154892.59 | 12258358.55 | 831391.92 | 0.138912E+10 | 0.00 | 0.28 |
Annual Sum or Average | 0.998268E+10 | 0.762191E+11 | 0.00 | 57581148.51 | 0.230519E+11 | 83820942.08 | 0.602082E+10 | 0.00 | 0.32 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 3701282.61 | 0.00 | 0.00 | 0.00 | 0.28 |
Maximum of Months | 0.414451E+10 | 0.185267E+11 | 0.00 | 14952675.20 | 0.678187E+10 | 82989550.16 | 0.138912E+10 | 0.00 | 0.36 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.849046E+09 | 0.00 | 0.00 | 327589.76 | 837797.82 | 0.230493E+09 | 0.116850E+09 | 0.00 | 0.30 |
February | 0.437729E+09 | 6290231.35 | 0.00 | 1734772.46 | 7949006.23 | 27153669.27 | 0.198317E+09 | 0.00 | 0.31 |
March | 93872617.11 | 0.179958E+09 | 0.00 | 3516610.13 | 53846552.08 | 0.00 | 0.241046E+09 | 0.00 | 0.36 |
April | 5490800.53 | 0.970691E+09 | 0.00 | 1866438.51 | 0.172755E+09 | 0.00 | 32441528.91 | 0.00 | 0.44 |
May | 16311.18 | 0.347634E+10 | 0.00 | 1745.66 | 0.342517E+09 | 0.00 | 4541.44 | 0.00 | 0.54 |
June | 0.00 | 0.522690E+10 | 0.00 | 0.00 | 0.584712E+09 | 0.00 | 0.00 | 0.00 | 0.57 |
July | 0.00 | 0.677887E+10 | 0.00 | 0.00 | 0.872181E+09 | 0.00 | 0.00 | 0.00 | 0.55 |
August | 0.00 | 0.669107E+10 | 0.00 | 0.00 | 0.606488E+09 | 0.00 | 0.00 | 0.00 | 0.51 |
September | 0.00 | 0.410473E+10 | 0.00 | 0.00 | 0.576126E+09 | 0.00 | 0.00 | 0.00 | 0.44 |
October | 13402719.68 | 0.850329E+09 | 0.00 | 593342.63 | 0.188002E+09 | 0.00 | 9730069.16 | 0.00 | 0.37 |
November | 0.209067E+09 | 25204342.21 | 0.00 | 2808644.87 | 36659957.75 | 569365.76 | 0.160069E+09 | 0.00 | 0.31 |
December | 0.785528E+09 | 0.00 | 0.00 | 664401.63 | 2774720.86 | 77378190.24 | 0.138920E+09 | 0.00 | 0.29 |
Annual Sum or Average | 0.239415E+10 | 0.283104E+11 | 0.00 | 11513545.66 | 0.344485E+10 | 0.335594E+09 | 0.897379E+09 | 0.00 | 0.42 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 837797.82 | 0.00 | 0.00 | 0.00 | 0.29 |
Maximum of Months | 0.849046E+09 | 0.677887E+10 | 0.00 | 3516610.13 | 0.872181E+09 | 0.230493E+09 | 0.241046E+09 | 0.00 | 0.57 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.585323E+09 | 0.00 | 0.00 | 686081.69 | 633326.22 | 0.119132E+09 | 0.205829E+09 | 0.00 | 0.36 |
February | 0.268394E+09 | 5025440.18 | 0.00 | 2220042.77 | 5738591.75 | 7399497.09 | 0.282978E+09 | 0.00 | 0.41 |
March | 54257198.73 | 0.169737E+09 | 0.00 | 3409758.83 | 30784422.68 | 0.00 | 0.241070E+09 | 0.00 | 0.52 |
April | 2992377.46 | 0.921997E+09 | 0.00 | 1642555.13 | 0.103541E+09 | 0.00 | 30007304.45 | 0.00 | 0.62 |
May | 12789.66 | 0.282643E+10 | 0.00 | 809.40 | 0.245104E+09 | 0.00 | 3483.91 | 0.00 | 0.70 |
June | 0.00 | 0.389944E+10 | 0.00 | 0.00 | 0.443548E+09 | 0.00 | 0.00 | 0.00 | 0.68 |
July | 0.00 | 0.488637E+10 | 0.00 | 0.00 | 0.676554E+09 | 0.00 | 0.00 | 0.00 | 0.64 |
August | 0.00 | 0.478655E+10 | 0.00 | 0.00 | 0.450476E+09 | 0.00 | 0.00 | 0.00 | 0.58 |
September | 0.00 | 0.313386E+10 | 0.00 | 0.00 | 0.424267E+09 | 0.00 | 0.00 | 0.00 | 0.54 |
October | 9376503.25 | 0.755573E+09 | 0.00 | 539054.55 | 0.112617E+09 | 0.00 | 8223894.73 | 0.00 | 0.50 |
November | 0.126937E+09 | 32987350.51 | 0.00 | 2889699.70 | 22237171.20 | 349615.67 | 0.184381E+09 | 0.00 | 0.43 |
December | 0.508090E+09 | 526764.08 | 0.00 | 1075337.50 | 1570762.83 | 36071785.82 | 0.226069E+09 | 0.00 | 0.36 |
Annual Sum or Average | 0.155538E+10 | 0.214185E+11 | 0.00 | 12463339.58 | 0.251707E+10 | 0.162953E+09 | 0.117856E+10 | 0.00 | 0.53 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 633326.22 | 0.00 | 0.00 | 0.00 | 0.36 |
Maximum of Months | 0.585323E+09 | 0.488637E+10 | 0.00 | 3409758.83 | 0.676554E+09 | 0.119132E+09 | 0.282978E+09 | 0.00 | 0.70 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.594454E+09 | 1311191.24 | 0.00 | 5361943.60 | 29733.71 | 0.125276E+09 | 0.109448E+10 | 0.00 | 0.47 |
February | 0.325513E+09 | 13204337.06 | 0.00 | 6745055.84 | 5993903.33 | 13949575.34 | 0.708812E+09 | 0.00 | 0.50 |
March | 75969824.40 | 0.297948E+09 | 0.00 | 6577545.87 | 31386036.89 | 0.00 | 0.439788E+09 | 0.00 | 0.54 |
April | 5510558.85 | 0.122902E+10 | 0.00 | 2547064.60 | 0.138280E+09 | 0.00 | 44191068.10 | 0.00 | 0.53 |
May | 17197.11 | 0.359119E+10 | 0.00 | 1704.75 | 0.350356E+09 | 0.00 | 4068.09 | 0.00 | 0.56 |
June | 0.00 | 0.516806E+10 | 0.00 | 0.00 | 0.606993E+09 | 0.00 | 0.00 | 0.00 | 0.56 |
July | 0.00 | 0.679530E+10 | 0.00 | 0.00 | 0.905641E+09 | 0.00 | 0.00 | 0.00 | 0.55 |
August | 0.00 | 0.706419E+10 | 0.00 | 0.00 | 0.586332E+09 | 0.00 | 0.00 | 0.00 | 0.53 |
September | 0.00 | 0.498268E+10 | 0.00 | 0.00 | 0.483427E+09 | 0.00 | 0.00 | 0.00 | 0.52 |
October | 13034455.65 | 0.144576E+10 | 0.00 | 1258913.97 | 0.120760E+09 | 0.00 | 18414927.40 | 0.00 | 0.58 |
November | 0.141027E+09 | 0.110593E+09 | 0.00 | 9542699.77 | 10250811.65 | 0.00 | 0.553168E+09 | 0.00 | 0.60 |
December | 0.527602E+09 | 5002878.26 | 0.00 | 6145593.88 | 402513.46 | 30388070.97 | 0.105038E+10 | 0.00 | 0.50 |
Annual Sum or Average | 0.168313E+10 | 0.307043E+11 | 0.00 | 38180522.29 | 0.323985E+10 | 0.169614E+09 | 0.390923E+10 | 0.00 | 0.54 |
Minimum of Months | 0.00 | 1311191.24 | 0.00 | 0.00 | 29733.71 | 0.00 | 0.00 | 0.00 | 0.47 |
Maximum of Months | 0.594454E+09 | 0.706419E+10 | 0.00 | 9542699.77 | 0.905641E+09 | 0.125276E+09 | 0.109448E+10 | 0.00 | 0.60 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.636970E+09 | 307566.17 | 0.00 | 1010031.90 | 397410.42 | 0.187672E+09 | 0.235183E+09 | 0.00 | 0.42 |
February | 0.355601E+09 | 6877877.83 | 0.00 | 1969025.19 | 6433688.21 | 23177601.80 | 0.224476E+09 | 0.00 | 0.44 |
March | 79957571.95 | 0.171522E+09 | 0.00 | 3429176.44 | 36115974.46 | 0.00 | 0.240076E+09 | 0.00 | 0.52 |
April | 4599296.07 | 0.886226E+09 | 0.00 | 1791816.04 | 0.119039E+09 | 0.00 | 28243069.62 | 0.00 | 0.62 |
May | 14236.60 | 0.281345E+10 | 0.00 | 948.20 | 0.287626E+09 | 0.00 | 3830.83 | 0.00 | 0.70 |
June | 0.00 | 0.404096E+10 | 0.00 | 0.00 | 0.507333E+09 | 0.00 | 0.00 | 0.00 | 0.71 |
July | 0.00 | 0.486515E+10 | 0.00 | 0.00 | 0.764764E+09 | 0.00 | 0.00 | 0.00 | 0.64 |
August | 0.00 | 0.482287E+10 | 0.00 | 0.00 | 0.524949E+09 | 0.00 | 0.00 | 0.00 | 0.59 |
September | 0.00 | 0.319378E+10 | 0.00 | 0.00 | 0.469998E+09 | 0.00 | 0.00 | 0.00 | 0.55 |
October | 11532705.69 | 0.716091E+09 | 0.00 | 571156.92 | 0.150261E+09 | 0.00 | 10034226.05 | 0.00 | 0.50 |
November | 0.170585E+09 | 29756153.01 | 0.00 | 2908197.02 | 27235316.91 | 546810.74 | 0.168718E+09 | 0.00 | 0.45 |
December | 0.612356E+09 | 717384.32 | 0.00 | 1177975.89 | 1618567.67 | 64864625.86 | 0.215910E+09 | 0.00 | 0.42 |
Annual Sum or Average | 0.187162E+10 | 0.215477E+11 | 0.00 | 12858327.59 | 0.289577E+10 | 0.276261E+09 | 0.112264E+10 | 0.00 | 0.55 |
Minimum of Months | 0.00 | 307566.17 | 0.00 | 0.00 | 397410.42 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 0.636970E+09 | 0.486515E+10 | 0.00 | 3429176.44 | 0.764764E+09 | 0.187672E+09 | 0.240076E+09 | 0.00 | 0.71 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.102756E+10 | 0.00 | 0.00 | 641553.14 | 149848.31 | 10829919.13 | 0.166501E+09 | 0.00 | 0.25 |
February | 0.479069E+09 | 4782621.19 | 0.00 | 1634772.62 | 4011403.34 | 0.00 | 0.191232E+09 | 0.00 | 0.26 |
March | 0.142123E+09 | 0.154862E+09 | 0.00 | 2493232.47 | 49701156.77 | 0.00 | 0.184403E+09 | 0.00 | 0.29 |
April | 15477173.32 | 0.798510E+09 | 0.00 | 570631.35 | 0.232064E+09 | 0.00 | 9290021.92 | 0.00 | 0.34 |
May | 314201.76 | 0.283487E+10 | 0.00 | 19566.39 | 0.432593E+09 | 0.00 | 666011.69 | 0.00 | 0.42 |
June | 0.00 | 0.444488E+10 | 0.00 | 0.00 | 0.643147E+09 | 0.00 | 0.00 | 0.00 | 0.47 |
July | 0.00 | 0.599383E+10 | 0.00 | 0.00 | 0.968151E+09 | 0.00 | 0.00 | 0.00 | 0.48 |
August | 0.00 | 0.613863E+10 | 0.00 | 0.00 | 0.712779E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
September | 0.00 | 0.390794E+10 | 0.00 | 0.00 | 0.598766E+09 | 0.00 | 0.00 | 0.00 | 0.40 |
October | 34444734.45 | 0.841220E+09 | 0.00 | 1018185.87 | 0.205749E+09 | 0.00 | 30802180.22 | 0.00 | 0.35 |
November | 0.230074E+09 | 30149539.18 | 0.00 | 3685657.54 | 26237666.75 | 0.00 | 0.236185E+09 | 0.00 | 0.28 |
December | 0.788191E+09 | 0.00 | 0.00 | 1517735.63 | 1582102.77 | 0.00 | 0.273431E+09 | 0.00 | 0.25 |
Annual Sum or Average | 0.271725E+10 | 0.251497E+11 | 0.00 | 11581335.01 | 0.387493E+10 | 10829919.13 | 0.109251E+10 | 0.00 | 0.35 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 149848.31 | 0.00 | 0.00 | 0.00 | 0.25 |
Maximum of Months | 0.102756E+10 | 0.613863E+10 | 0.00 | 3685657.54 | 0.968151E+09 | 10829919.13 | 0.273431E+09 | 0.00 | 0.48 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.573275E+09 | 90153.15 | 0.00 | 1467380.35 | 16714.25 | 1963077.49 | 0.335663E+09 | 0.00 | 0.31 |
February | 0.250907E+09 | 3717168.71 | 0.00 | 2517108.45 | 2577601.64 | 0.00 | 0.315029E+09 | 0.00 | 0.35 |
March | 79692532.11 | 0.141210E+09 | 0.00 | 3148866.20 | 31902080.63 | 0.00 | 0.221712E+09 | 0.00 | 0.42 |
April | 9218076.02 | 0.807240E+09 | 0.00 | 764835.37 | 0.115412E+09 | 0.00 | 13911139.68 | 0.00 | 0.49 |
May | 224079.44 | 0.247635E+10 | 0.00 | 17149.86 | 0.225351E+09 | 0.00 | 484948.30 | 0.00 | 0.56 |
June | 0.00 | 0.344372E+10 | 0.00 | 0.00 | 0.406443E+09 | 0.00 | 0.00 | 0.00 | 0.56 |
July | 0.00 | 0.447119E+10 | 0.00 | 0.00 | 0.608969E+09 | 0.00 | 0.00 | 0.00 | 0.55 |
August | 0.00 | 0.446726E+10 | 0.00 | 0.00 | 0.443272E+09 | 0.00 | 0.00 | 0.00 | 0.52 |
September | 0.00 | 0.300775E+10 | 0.00 | 0.00 | 0.380904E+09 | 0.00 | 0.00 | 0.00 | 0.49 |
October | 21684107.52 | 0.727729E+09 | 0.00 | 1106350.40 | 0.113548E+09 | 0.00 | 33016300.08 | 0.00 | 0.45 |
November | 0.126132E+09 | 26432155.96 | 0.00 | 4137801.60 | 18618517.69 | 0.00 | 0.275503E+09 | 0.00 | 0.38 |
December | 0.448633E+09 | 96939.44 | 0.00 | 2217485.13 | 1031467.42 | 0.00 | 0.394778E+09 | 0.00 | 0.32 |
Annual Sum or Average | 0.150977E+10 | 0.195728E+11 | 0.00 | 15376977.37 | 0.234805E+10 | 1963077.49 | 0.159010E+10 | 0.00 | 0.45 |
Minimum of Months | 0.00 | 90153.15 | 0.00 | 0.00 | 16714.25 | 0.00 | 0.00 | 0.00 | 0.31 |
Maximum of Months | 0.573275E+09 | 0.447119E+10 | 0.00 | 4137801.60 | 0.608969E+09 | 1963077.49 | 0.394778E+09 | 0.00 | 0.56 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.737829E+09 | 268166.47 | 0.00 | 3525482.47 | 21181.90 | 0.257494E+09 | 0.674120E+09 | 0.00 | 0.37 |
February | 0.328442E+09 | 11424732.53 | 0.00 | 5595379.24 | 2106897.97 | 0.117061E+09 | 0.526206E+09 | 0.00 | 0.41 |
March | 0.112016E+09 | 0.346658E+09 | 0.00 | 5233094.19 | 19861530.98 | 18810416.67 | 0.328187E+09 | 0.00 | 0.47 |
April | 16397206.19 | 0.139206E+10 | 0.00 | 974808.69 | 0.159685E+09 | 0.00 | 12408678.94 | 0.00 | 0.50 |
May | 203753.98 | 0.403001E+10 | 0.00 | 34711.47 | 0.394357E+09 | 0.00 | 1078743.71 | 0.00 | 0.56 |
June | 0.00 | 0.585858E+10 | 0.00 | 0.00 | 0.640093E+09 | 0.00 | 0.00 | 0.00 | 0.60 |
July | 0.00 | 0.735007E+10 | 0.00 | 0.00 | 0.966733E+09 | 0.00 | 0.00 | 0.00 | 0.57 |
August | 0.00 | 0.791212E+10 | 0.00 | 0.00 | 0.640479E+09 | 0.00 | 0.00 | 0.00 | 0.58 |
September | 0.00 | 0.557424E+10 | 0.00 | 0.00 | 0.464976E+09 | 0.00 | 0.00 | 0.00 | 0.54 |
October | 35907316.45 | 0.164480E+10 | 0.00 | 1668135.12 | 91642488.23 | 0.00 | 40719779.65 | 0.00 | 0.56 |
November | 0.169461E+09 | 0.112618E+09 | 0.00 | 10214754.33 | 7886750.89 | 25771732.71 | 0.554582E+09 | 0.00 | 0.54 |
December | 0.495181E+09 | 1680546.66 | 0.00 | 5538039.22 | 510813.54 | 0.166751E+09 | 0.869322E+09 | 0.00 | 0.40 |
Annual Sum or Average | 0.189544E+10 | 0.342345E+11 | 0.00 | 32784404.73 | 0.338835E+10 | 0.585887E+09 | 0.300662E+10 | 0.00 | 0.51 |
Minimum of Months | 0.00 | 268166.47 | 0.00 | 0.00 | 21181.90 | 0.00 | 0.00 | 0.00 | 0.37 |
Maximum of Months | 0.737829E+09 | 0.791212E+10 | 0.00 | 10214754.33 | 0.966733E+09 | 0.257494E+09 | 0.869322E+09 | 0.00 | 0.60 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.699881E+09 | 97663.52 | 0.00 | 1308312.88 | 17393.15 | 3558620.22 | 0.252350E+09 | 0.00 | 0.32 |
February | 0.320565E+09 | 5922150.15 | 0.00 | 1980061.02 | 2022919.64 | 0.00 | 0.219956E+09 | 0.00 | 0.34 |
March | 92093765.78 | 0.166614E+09 | 0.00 | 2645277.70 | 25591970.61 | 0.00 | 0.187823E+09 | 0.00 | 0.41 |
April | 10575954.06 | 0.857720E+09 | 0.00 | 488838.85 | 0.100952E+09 | 0.00 | 7929647.64 | 0.00 | 0.49 |
May | 151184.50 | 0.255665E+10 | 0.00 | 20453.90 | 0.203010E+09 | 0.00 | 605688.54 | 0.00 | 0.56 |
June | 0.00 | 0.369860E+10 | 0.00 | 0.00 | 0.361177E+09 | 0.00 | 0.00 | 0.00 | 0.59 |
July | 0.00 | 0.451017E+10 | 0.00 | 0.00 | 0.605116E+09 | 0.00 | 0.00 | 0.00 | 0.55 |
August | 0.00 | 0.454985E+10 | 0.00 | 0.00 | 0.432725E+09 | 0.00 | 0.00 | 0.00 | 0.53 |
September | 0.00 | 0.312496E+10 | 0.00 | 0.00 | 0.352501E+09 | 0.00 | 0.00 | 0.00 | 0.49 |
October | 22895579.87 | 0.758362E+09 | 0.00 | 848415.08 | 0.110419E+09 | 0.00 | 26008279.09 | 0.00 | 0.45 |
November | 0.143048E+09 | 35705205.33 | 0.00 | 3582032.35 | 16022723.01 | 0.00 | 0.231857E+09 | 0.00 | 0.38 |
December | 0.513295E+09 | 137265.22 | 0.00 | 1991810.07 | 1073363.29 | 0.00 | 0.336962E+09 | 0.00 | 0.33 |
Annual Sum or Average | 0.180250E+10 | 0.202648E+11 | 0.00 | 12865201.85 | 0.221063E+10 | 3558620.22 | 0.126349E+10 | 0.00 | 0.45 |
Minimum of Months | 0.00 | 97663.52 | 0.00 | 0.00 | 17393.15 | 0.00 | 0.00 | 0.00 | 0.32 |
Maximum of Months | 0.699881E+09 | 0.454985E+10 | 0.00 | 3582032.35 | 0.605116E+09 | 3558620.22 | 0.336962E+09 | 0.00 | 0.59 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.105548E+10 | 0.00 | 0.00 | 753346.30 | 648204.61 | 31732446.36 | 0.195350E+09 | 0.00 | 0.28 |
February | 0.455867E+09 | 5741437.86 | 0.00 | 2252950.22 | 4329969.93 | 0.00 | 0.279930E+09 | 0.00 | 0.30 |
March | 0.109450E+09 | 0.190999E+09 | 0.00 | 3804910.56 | 47204190.37 | 0.00 | 0.285183E+09 | 0.00 | 0.36 |
April | 14259565.66 | 0.105813E+10 | 0.00 | 1178698.37 | 0.179089E+09 | 0.00 | 20348793.25 | 0.00 | 0.44 |
May | 161361.73 | 0.364858E+10 | 0.00 | 27524.93 | 0.320195E+09 | 0.00 | 372931.09 | 0.00 | 0.54 |
June | 0.00 | 0.542645E+10 | 0.00 | 0.00 | 0.518801E+09 | 0.00 | 0.00 | 0.00 | 0.56 |
July | 0.00 | 0.682787E+10 | 0.00 | 0.00 | 0.757823E+09 | 0.00 | 0.00 | 0.00 | 0.53 |
August | 0.00 | 0.680530E+10 | 0.00 | 0.00 | 0.575429E+09 | 0.00 | 0.00 | 0.00 | 0.50 |
September | 0.00 | 0.426254E+10 | 0.00 | 0.00 | 0.512255E+09 | 0.00 | 0.00 | 0.00 | 0.44 |
October | 33696402.52 | 0.921875E+09 | 0.00 | 793811.51 | 0.156713E+09 | 0.00 | 17024923.24 | 0.00 | 0.37 |
November | 0.238411E+09 | 32577426.84 | 0.00 | 3288293.31 | 24318067.41 | 0.00 | 0.214642E+09 | 0.00 | 0.30 |
December | 0.872264E+09 | 0.00 | 0.00 | 1270370.02 | 3870564.39 | 427362.60 | 0.242046E+09 | 0.00 | 0.28 |
Annual Sum or Average | 0.277959E+10 | 0.291801E+11 | 0.00 | 13369905.22 | 0.310068E+10 | 32159808.96 | 0.125490E+10 | 0.00 | 0.41 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 648204.61 | 0.00 | 0.00 | 0.00 | 0.28 |
Maximum of Months | 0.105548E+10 | 0.682787E+10 | 0.00 | 3804910.56 | 0.757823E+09 | 31732446.36 | 0.285183E+09 | 0.00 | 0.56 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.687722E+09 | 196398.55 | 0.00 | 1129575.70 | 308071.02 | 18933571.72 | 0.321548E+09 | 0.00 | 0.36 |
February | 0.289982E+09 | 4305965.90 | 0.00 | 2630883.48 | 3536653.84 | 167106.91 | 0.360540E+09 | 0.00 | 0.41 |
March | 72579939.27 | 0.158497E+09 | 0.00 | 3796303.65 | 32249147.35 | 0.00 | 0.284894E+09 | 0.00 | 0.51 |
April | 9511162.95 | 0.969944E+09 | 0.00 | 1201109.34 | 0.109264E+09 | 0.00 | 23123234.72 | 0.00 | 0.62 |
May | 178881.14 | 0.294502E+10 | 0.00 | 16016.74 | 0.233871E+09 | 0.00 | 216277.85 | 0.00 | 0.69 |
June | 0.00 | 0.401135E+10 | 0.00 | 0.00 | 0.418676E+09 | 0.00 | 0.00 | 0.00 | 0.67 |
July | 0.00 | 0.489098E+10 | 0.00 | 0.00 | 0.604582E+09 | 0.00 | 0.00 | 0.00 | 0.61 |
August | 0.00 | 0.481022E+10 | 0.00 | 0.00 | 0.429533E+09 | 0.00 | 0.00 | 0.00 | 0.57 |
September | 0.00 | 0.318055E+10 | 0.00 | 0.00 | 0.396159E+09 | 0.00 | 0.00 | 0.00 | 0.53 |
October | 24854026.18 | 0.760995E+09 | 0.00 | 879391.03 | 99095667.70 | 0.00 | 18953903.98 | 0.00 | 0.49 |
November | 0.162797E+09 | 29457008.37 | 0.00 | 3324975.87 | 18471117.49 | 0.00 | 0.236771E+09 | 0.00 | 0.42 |
December | 0.564134E+09 | 757517.89 | 0.00 | 1597507.91 | 2273502.88 | 714016.79 | 0.339487E+09 | 0.00 | 0.36 |
Annual Sum or Average | 0.181176E+10 | 0.217623E+11 | 0.00 | 14575763.72 | 0.234802E+10 | 19814695.42 | 0.158553E+10 | 0.00 | 0.52 |
Minimum of Months | 0.00 | 196398.55 | 0.00 | 0.00 | 308071.02 | 0.00 | 0.00 | 0.00 | 0.36 |
Maximum of Months | 0.687722E+09 | 0.489098E+10 | 0.00 | 3796303.65 | 0.604582E+09 | 18933571.72 | 0.360540E+09 | 0.00 | 0.69 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.695664E+09 | 1073071.81 | 0.00 | 6452781.92 | 84392.39 | 13131923.10 | 0.134454E+10 | 0.00 | 0.50 |
February | 0.328985E+09 | 14314181.86 | 0.00 | 7148332.66 | 2223750.41 | 0.00 | 0.817053E+09 | 0.00 | 0.50 |
March | 96355680.09 | 0.333935E+09 | 0.00 | 6698099.35 | 18610943.62 | 0.00 | 0.481802E+09 | 0.00 | 0.54 |
April | 14027872.10 | 0.139064E+10 | 0.00 | 1543206.39 | 0.124585E+09 | 0.00 | 25850572.57 | 0.00 | 0.54 |
May | 161548.53 | 0.379622E+10 | 0.00 | 27540.28 | 0.313686E+09 | 0.00 | 373733.10 | 0.00 | 0.55 |
June | 0.00 | 0.536958E+10 | 0.00 | 0.00 | 0.530632E+09 | 0.00 | 0.00 | 0.00 | 0.56 |
July | 0.00 | 0.685909E+10 | 0.00 | 0.00 | 0.768470E+09 | 0.00 | 0.00 | 0.00 | 0.53 |
August | 0.00 | 0.723388E+10 | 0.00 | 0.00 | 0.506721E+09 | 0.00 | 0.00 | 0.00 | 0.52 |
September | 0.00 | 0.521511E+10 | 0.00 | 0.00 | 0.418577E+09 | 0.00 | 0.00 | 0.00 | 0.52 |
October | 28793286.89 | 0.161333E+10 | 0.00 | 1476428.77 | 69522237.06 | 0.00 | 30855653.70 | 0.00 | 0.58 |
November | 0.159013E+09 | 0.122197E+09 | 0.00 | 9607593.01 | 6842879.58 | 0.00 | 0.631046E+09 | 0.00 | 0.59 |
December | 0.546924E+09 | 5799455.30 | 0.00 | 7164510.60 | 1031005.73 | 287145.81 | 0.132134E+10 | 0.00 | 0.52 |
Annual Sum or Average | 0.186992E+10 | 0.319552E+11 | 0.00 | 40118492.97 | 0.276099E+10 | 13419068.91 | 0.465286E+10 | 0.00 | 0.54 |
Minimum of Months | 0.00 | 1073071.81 | 0.00 | 0.00 | 84392.39 | 0.00 | 0.00 | 0.00 | 0.50 |
Maximum of Months | 0.695664E+09 | 0.723388E+10 | 0.00 | 9607593.01 | 0.768470E+09 | 13131923.10 | 0.134454E+10 | 0.00 | 0.59 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.817583E+09 | 384494.52 | 0.00 | 1313034.26 | 156492.58 | 26803040.05 | 0.284684E+09 | 0.00 | 0.40 |
February | 0.373244E+09 | 8138583.60 | 0.00 | 2245006.38 | 2339038.39 | 312986.99 | 0.268951E+09 | 0.00 | 0.42 |
March | 91156465.71 | 0.192586E+09 | 0.00 | 3444743.44 | 25724012.97 | 0.00 | 0.263770E+09 | 0.00 | 0.51 |
April | 11891729.53 | 0.102741E+10 | 0.00 | 966790.72 | 99733964.52 | 0.00 | 15370960.28 | 0.00 | 0.63 |
May | 163760.74 | 0.306852E+10 | 0.00 | 18208.36 | 0.227612E+09 | 0.00 | 253562.82 | 0.00 | 0.70 |
June | 0.00 | 0.430308E+10 | 0.00 | 0.00 | 0.407515E+09 | 0.00 | 0.00 | 0.00 | 0.71 |
July | 0.00 | 0.498708E+10 | 0.00 | 0.00 | 0.599892E+09 | 0.00 | 0.00 | 0.00 | 0.62 |
August | 0.00 | 0.496103E+10 | 0.00 | 0.00 | 0.447846E+09 | 0.00 | 0.00 | 0.00 | 0.58 |
September | 0.00 | 0.334237E+10 | 0.00 | 0.00 | 0.388465E+09 | 0.00 | 0.00 | 0.00 | 0.54 |
October | 28885628.05 | 0.810870E+09 | 0.00 | 579437.54 | 98056917.46 | 0.00 | 11790264.35 | 0.00 | 0.49 |
November | 0.188544E+09 | 39101453.81 | 0.00 | 3075108.61 | 16839187.54 | 0.00 | 0.200886E+09 | 0.00 | 0.43 |
December | 0.683044E+09 | 822175.94 | 0.00 | 1558310.77 | 2470894.67 | 1671823.10 | 0.290288E+09 | 0.00 | 0.39 |
Annual Sum or Average | 0.219451E+10 | 0.227414E+11 | 0.00 | 13200640.07 | 0.231665E+10 | 28787850.15 | 0.133599E+10 | 0.00 | 0.53 |
Minimum of Months | 0.00 | 384494.52 | 0.00 | 0.00 | 156492.58 | 0.00 | 0.00 | 0.00 | 0.39 |
Maximum of Months | 0.817583E+09 | 0.498708E+10 | 0.00 | 3444743.44 | 0.599892E+09 | 26803040.05 | 0.290288E+09 | 0.00 | 0.71 |
Report: HeatEmissionsReportMonthly
For: Environment
Timestamp: 2023-10-16 08:35:14
Custom Monthly ReportSITE TOTAL SURFACE HEAT EMISSION TO AIR [J] | SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] | SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] | AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] | HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J] | |
January | 0.168768E+12 | 0.432533E+10 | 0.00 | 0.697429E+11 | 0.651137E+11 |
February | 0.187362E+12 | 0.299959E+10 | 0.00 | 0.394290E+11 | 0.987234E+11 |
March | 0.248549E+12 | 0.607206E+09 | 0.00 | 0.889956E+10 | 0.193488E+12 |
April | 0.266997E+12 | -0.329997E+10 | 0.00 | -0.374880E+11 | 0.288360E+12 |
May | 0.277871E+12 | -0.958431E+10 | 0.00 | -0.101381E+12 | 0.420975E+12 |
June | 0.256191E+12 | -0.115537E+11 | 0.00 | -0.151549E+12 | 0.466220E+12 |
July | 0.214289E+12 | -0.163882E+11 | 0.00 | -0.203287E+12 | 0.488144E+12 |
August | 0.184114E+12 | -0.150777E+11 | 0.00 | -0.206398E+12 | 0.479864E+12 |
September | 0.201043E+12 | -0.967394E+10 | 0.00 | -0.153374E+12 | 0.381797E+12 |
October | 0.200955E+12 | -0.234785E+10 | 0.00 | -0.344400E+11 | 0.260148E+12 |
November | 0.178589E+12 | 0.110077E+10 | 0.00 | 0.239129E+11 | 0.155463E+12 |
December | 0.153871E+12 | 0.386286E+10 | 0.00 | 0.629446E+11 | 0.801890E+11 |
Annual Sum or Average | 0.253860E+13 | -0.550299E+11 | 0.00 | -0.682987E+12 | 0.337849E+13 |
Minimum of Months | 0.153871E+12 | -0.163882E+11 | 0.00 | -0.206398E+12 | 0.651137E+11 |