Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 08:35
Tabular Output Report in Format: HTML
Building: OfficeMedium
Environment: RUNPERIOD 1 ** Ho Chi Minh City-Tan Son Nhat Intl AP - VNM IWEC2 WMO#=489000
Simulation Timestamp: 2023-10-16 08:35:24
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 2051.96 | 411.86 | 411.86 |
Net Site Energy | 2051.96 | 411.86 | 411.86 |
Total Source Energy | 6319.71 | 1268.46 | 1268.46 |
Net Source Energy | 6319.71 | 1268.46 | 1268.46 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 1.200 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil No 1 | 1.050 |
Fuel Oil No 2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 4982.19 |
Net Conditioned Building Area | 4982.19 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 867.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 202.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 48.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 705.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 11.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 113.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 17.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 85.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 271.06 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1966.10 | 85.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 271.06 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 867.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 202.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 48.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 584.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ElevatorLift | 120.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ElevatorLightsFan | 0.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Equipment | Transformer | 11.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 113.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 17.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 271.06 | |
Water Heater | 0.00 | 85.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | Unassigned | 867.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GENERAL | 202.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | Unassigned | 48.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | GENERAL | 705.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | Unassigned | 11.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Unassigned | 113.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | Unassigned | 0.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | Unassigned | 17.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Unassigned | 0.00 | 85.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 271.06 |
Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 50.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 196.93 | 17.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 |
Other | 147.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 394.63 | 17.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 50.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 196.93 | 17.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 |
Other | 147.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 394.63 | 17.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 1966.099 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 1966.099 | 100.00 |
Total On-Site and Utility Electric Sources | 1966.099 | 100.00 |
Total Electricity End Uses | 1966.099 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | 0.00 |
Air to Air Heat Recovery for Cooling | 287.42 | 100.00 |
Air to Air Heat Recovery for Heating | 0.00 | 0.00 |
High-Temperature Geothermal* | 0.00 | 0.00 |
Solar Water Thermal | 0.00 | 0.00 |
Solar Air Thermal | 0.00 | 0.00 |
Total On-Site Thermal Sources | 287.42 | 100.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 271.06 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 271.06 | 100.00 |
Total Water End Uses | 271.06 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 0.00 |
Time Setpoint Not Met During Occupied Cooling | 838.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 2152.83 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Environment |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2021
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Environment |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME OFFICEMEDIUM
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 0A
| Environment |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY VNM_HOCHIMINH_TANSONHOA
| Environment |ZoneCoolingSummaryMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |ZoneHeatingSummaryMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |ZoneElectricSummaryMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |SpaceGainsMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | FIRSTFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM |PeakSpaceGainsMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | FIRSTFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM |SpaceGainComponentsAtCoolingPeakMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |ComfortReportSimple55Monthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |OccupantComfortDataSummaryMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |DXReportMonthly
| PACU_VAV_BOT COOLING COIL | PACU_VAV_MID COOLING COIL | PACU_VAV_TOP COOLING COIL |WindowReportMonthly
| PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW |WindowEnergyReportMonthly
| PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW |WindowZoneSummaryMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |WindowEnergyZoneSummaryMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| SWHSYS1 WATER HEATER |DaylightingReportMonthly
| PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_4_DAYLCTRL |CoilReportMonthly
| CORE_BOTTOM VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | CORE_MID VAV BOX REHEAT COIL | PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | CORE_TOP VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | PACU_VAV_BOT HEATING COIL | PACU_VAV_MID HEATING COIL | PACU_VAV_TOP HEATING COIL | PACU_VAV_BOT COOLING COIL | PACU_VAV_MID COOLING COIL | PACU_VAV_TOP COOLING COIL |PlantLoopDemandReportMonthly
| SWHSYS1 |FanReportMonthly
| PACU_VAV_BOT FAN | PACU_VAV_MID FAN | PACU_VAV_TOP FAN |PumpReportMonthly
| SWHSYS1 PUMP |CondLoopDemandReportMonthly
| SWHSYS1 |ZoneTemperatureOscillationReportMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |AirLoopSystemEnergyAndWaterUseMonthly
| PACU_VAV_BOT | PACU_VAV_MID | PACU_VAV_TOP |AirLoopSystemComponentLoadsMonthly
| PACU_VAV_BOT | PACU_VAV_MID | PACU_VAV_TOP |AirLoopSystemComponentEnergyUseMonthly
| PACU_VAV_BOT | PACU_VAV_MID | PACU_VAV_TOP |MechanicalVentilationLoadsMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |HeatEmissionsReportMonthly
| Environment |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
GeneralValue | |
Program Version and Build | EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 08:35 |
RunPeriod | RUNPERIOD 1 |
Weather File | Ho Chi Minh City-Tan Son Nhat Intl AP - VNM IWEC2 WMO#=489000 |
Latitude [deg] | 10.82 |
Longitude [deg] | 106.67 |
Elevation [m] | 5.00 |
Time Zone | 7.00 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1977.67 | 593.30 | 395.53 | 593.30 | 395.53 |
Above Ground Wall Area [m2] | 1977.67 | 593.30 | 395.53 | 593.30 | 395.53 |
Window Opening Area [m2] | 593.29 | 177.99 | 118.66 | 177.99 | 118.66 |
Gross Window-Wall Ratio [%] | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 |
Above Ground Window-Wall Ratio [%] | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1977.67 | 593.30 | 395.53 | 593.30 | 395.53 |
Above Ground Wall Area [m2] | 1977.67 | 593.30 | 395.53 | 593.30 | 395.53 |
Window Opening Area [m2] | 593.29 | 177.99 | 118.66 | 177.99 | 118.66 |
Gross Window-Wall Ratio [%] | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 |
Above Ground Window-Wall Ratio [%] | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 |
Total | |
Gross Roof Area [m2] | 1660.73 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
CORE_BOTTOM | 983.54 | Yes | Yes | 2698.04 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.9322 | 18.58 | 24.8342 |
TOPFLOOR_PLENUM | 1660.73 | Yes | No | 2024.76 | 1.00 | 202.84 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 | |
MIDFLOOR_PLENUM | 1660.73 | Yes | No | 2024.76 | 1.00 | 202.84 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 | |
FIRSTFLOOR_PLENUM | 1660.73 | Yes | No | 2024.76 | 1.00 | 202.84 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 | |
CORE_MID | 983.54 | Yes | Yes | 2698.04 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.9322 | 18.58 | 8.0700 |
CORE_TOP | 983.54 | Yes | Yes | 2698.04 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.9322 | 18.58 | 8.0700 |
PERIMETER_TOP_ZN_3 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 59.33 | 59.33 | 5.9322 | 18.58 | 8.0700 |
PERIMETER_TOP_ZN_2 | 131.26 | Yes | Yes | 360.08 | 1.00 | 91.28 | 0.00 | 39.55 | 39.55 | 5.9322 | 18.58 | 8.0695 |
PERIMETER_TOP_ZN_1 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 59.33 | 59.33 | 5.9322 | 18.58 | 8.0699 |
PERIMETER_TOP_ZN_4 | 131.25 | Yes | Yes | 360.05 | 1.00 | 91.28 | 0.00 | 39.55 | 39.55 | 5.9322 | 18.58 | 8.0700 |
PERIMETER_BOT_ZN_3 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 59.33 | 59.33 | 5.9322 | 18.58 | 8.0700 |
PERIMETER_BOT_ZN_2 | 131.26 | Yes | Yes | 360.08 | 1.00 | 91.28 | 0.00 | 39.55 | 39.55 | 5.9322 | 18.58 | 8.0695 |
PERIMETER_BOT_ZN_1 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 59.33 | 59.33 | 5.9322 | 18.58 | 8.0699 |
PERIMETER_BOT_ZN_4 | 131.25 | Yes | Yes | 360.05 | 1.00 | 91.28 | 0.00 | 39.55 | 39.55 | 5.9322 | 18.58 | 8.0700 |
PERIMETER_MID_ZN_3 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 59.33 | 59.33 | 5.9322 | 18.58 | 8.0700 |
PERIMETER_MID_ZN_2 | 131.26 | Yes | Yes | 360.08 | 1.00 | 91.28 | 0.00 | 39.55 | 39.55 | 5.9322 | 18.58 | 8.0695 |
PERIMETER_MID_ZN_1 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 59.33 | 59.33 | 5.9322 | 18.58 | 8.0699 |
PERIMETER_MID_ZN_4 | 131.25 | Yes | Yes | 360.05 | 1.00 | 91.28 | 0.00 | 39.55 | 39.55 | 5.9322 | 18.58 | 8.0700 |
Total | 4982.19 | 13667.13 | 1369.16 | 0.00 | 593.29 | 593.29 | 5.9322 | 18.58 | 11.3794 | |||
Conditioned Total | 4982.19 | 13667.13 | 1369.16 | 0.00 | 593.29 | 593.29 | 5.9322 | 18.58 | 11.3794 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 4982.19 | 6074.28 | 608.51 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
CORE_BOTTOM | 983.54 | Yes | Yes | 1.00 | CORE_BOTTOM | GENERAL | CORE_BOTTOM | 5.9322 | 18.58 | 24.8342 | |
TOPFLOOR_PLENUM | 1660.73 | Yes | No | 1.00 | TOPFLOOR_PLENUM | GENERAL | TOPFLOOR_PLENUM | 0.0000 | 0.00 | 0.0000 | |
MIDFLOOR_PLENUM | 1660.73 | Yes | No | 1.00 | MIDFLOOR_PLENUM | GENERAL | MIDFLOOR_PLENUM | 0.0000 | 0.00 | 0.0000 | |
FIRSTFLOOR_PLENUM | 1660.73 | Yes | No | 1.00 | FIRSTFLOOR_PLENUM | GENERAL | FIRSTFLOOR_PLENUM | 0.0000 | 0.00 | 0.0000 | |
CORE_MID | 983.54 | Yes | Yes | 1.00 | CORE_MID | GENERAL | CORE_MID | 5.9322 | 18.58 | 8.0700 | |
CORE_TOP | 983.54 | Yes | Yes | 1.00 | CORE_TOP | GENERAL | CORE_TOP | 5.9322 | 18.58 | 8.0700 | |
PERIMETER_TOP_ZN_3 | 207.34 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_3 | GENERAL | PERIMETER_TOP_ZN_3 | 5.9322 | 18.58 | 8.0700 | |
PERIMETER_TOP_ZN_2 | 131.26 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_2 | GENERAL | PERIMETER_TOP_ZN_2 | 5.9322 | 18.58 | 8.0695 | |
PERIMETER_TOP_ZN_1 | 207.34 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_1 | GENERAL | PERIMETER_TOP_ZN_1 | 5.9322 | 18.58 | 8.0699 | |
PERIMETER_TOP_ZN_4 | 131.25 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_4 | GENERAL | PERIMETER_TOP_ZN_4 | 5.9322 | 18.58 | 8.0700 | |
PERIMETER_BOT_ZN_3 | 207.34 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_3 | GENERAL | PERIMETER_BOT_ZN_3 | 5.9322 | 18.58 | 8.0700 | |
PERIMETER_BOT_ZN_2 | 131.26 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_2 | GENERAL | PERIMETER_BOT_ZN_2 | 5.9322 | 18.58 | 8.0695 | |
PERIMETER_BOT_ZN_1 | 207.34 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_1 | GENERAL | PERIMETER_BOT_ZN_1 | 5.9322 | 18.58 | 8.0699 | |
PERIMETER_BOT_ZN_4 | 131.25 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_4 | GENERAL | PERIMETER_BOT_ZN_4 | 5.9322 | 18.58 | 8.0700 | |
PERIMETER_MID_ZN_3 | 207.34 | Yes | Yes | 1.00 | PERIMETER_MID_ZN_3 | GENERAL | PERIMETER_MID_ZN_3 | 5.9322 | 18.58 | 8.0700 | |
PERIMETER_MID_ZN_2 | 131.26 | Yes | Yes | 1.00 | PERIMETER_MID_ZN_2 | GENERAL | PERIMETER_MID_ZN_2 | 5.9322 | 18.58 | 8.0695 | |
PERIMETER_MID_ZN_1 | 207.34 | Yes | Yes | 1.00 | PERIMETER_MID_ZN_1 | GENERAL | PERIMETER_MID_ZN_1 | 5.9322 | 18.58 | 8.0699 | |
PERIMETER_MID_ZN_4 | 131.25 | Yes | Yes | 1.00 | PERIMETER_MID_ZN_4 | GENERAL | PERIMETER_MID_ZN_4 | 5.9322 | 18.58 | 8.0700 | |
Total | 4982.19 | 5.9322 | 9.29 | 11.3794 | |||||||
Conditioned Total | 4982.19 | 5.9322 | 9.29 | 11.3794 | |||||||
Unconditioned Total | 0.00 | 0.0000 | 0.00 | 0.0000 | |||||||
Not Part of Total | 4982.19 | 0.0000 | 0.00 | 0.0000 |
Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
GENERAL | 4982.19 | 4982.19 | 0.00 | 4982.19 | 5.9322 | 18.58 | 11.3794 |
Total | 4982.19 | 4982.19 | 0.00 | 4982.19 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
End UsesElectricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 13-JUN-15:20 | 05-JAN-12:09 | - | - | - | - | - | - | - | - | - | - | 03-JAN-12:09 |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 86862.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 16818.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 42072.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 827.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 14640.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 907.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 8617.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 162130.67 | 8617.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 86862.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 16818.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 34487.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ElevatorLift | 7527.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ElevatorLightsFan | 57.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Equipment | Transformer | 827.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 14640.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 907.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Water Heater | 0.00 | 8617.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 2748.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 639.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 153.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 2234.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 36.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 358.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 54.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 93.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 6226.64 | 93.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 551.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 128.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 30.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 448.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 7.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 71.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 10.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 18.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1249.78 | 18.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 551.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 128.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 30.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 448.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 7.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 71.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 10.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 18.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1249.78 | 18.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
AirTerminal:SingleDuct:VAV:ReheatDesign Size Maximum Air Flow Rate [m3/s] | Design Size Constant Minimum Air Flow Fraction | User-Specified Constant Minimum Air Flow Fraction | Design Size Minimum Air Flow Rate [m3/s] | Design Size Maximum Flow Fraction during Reheat [] | User-Specified Maximum Flow Fraction during Reheat [] | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | |
CORE_BOTTOM VAV BOX COMPONENT | 2.70 | 0.277272 | 0.282000 | 0.762234 | 0.739393 | 0.500000 | 0.001374 |
CORE_MID VAV BOX COMPONENT | 1.95 | 0.384866 | 0.372000 | 0.724402 | 1.00 | 0.500000 | 0.000990 |
CORE_TOP VAV BOX COMPONENT | 2.14 | 0.349626 | 0.357000 | 0.765262 | 0.932335 | 0.500000 | 0.001090 |
PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | 0.688614 | 0.229434 | 0.234000 | 0.161136 | 0.611824 | 0.500000 | 0.001661 |
PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | 0.614561 | 0.162753 | 0.200000 | 0.122912 | 0.434009 | 0.500000 | 0.002341 |
PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | 0.670581 | 0.235604 | 0.241000 | 0.161610 | 0.628277 | 0.500000 | 0.001617 |
PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | 0.714652 | 0.139949 | 0.200000 | 0.142930 | 0.373199 | 0.500000 | 0.002722 |
PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | 0.577544 | 0.273558 | 0.279000 | 0.161135 | 0.729487 | 0.500000 | 0.001393 |
PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | 0.551415 | 0.181391 | 0.200000 | 0.110283 | 0.483710 | 0.500000 | 0.002100 |
PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | 0.561691 | 0.281279 | 0.286000 | 0.160644 | 0.750076 | 0.500000 | 0.001355 |
PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | 0.588715 | 0.169887 | 0.200000 | 0.117743 | 0.453033 | 0.500000 | 0.002243 |
PERIMETER_MID_ZN_3 VAV BOX COMPONENT | 0.576957 | 0.273836 | 0.264000 | 0.152317 | 0.730230 | 0.500000 | 0.001391 |
PERIMETER_MID_ZN_2 VAV BOX COMPONENT | 0.583252 | 0.171490 | 0.200000 | 0.116650 | 0.457306 | 0.500000 | 0.002222 |
PERIMETER_MID_ZN_1 VAV BOX COMPONENT | 0.561829 | 0.281210 | 0.272000 | 0.152817 | 0.749892 | 0.500000 | 0.001355 |
PERIMETER_MID_ZN_4 VAV BOX COMPONENT | 0.628832 | 0.159049 | 0.200000 | 0.125766 | 0.424131 | 0.500000 | 0.002395 |
Design Size Nominal Capacity [W] | |
CORE_BOTTOM VAV BOX REHEAT COIL | 25445.72 |
CORE_MID VAV BOX REHEAT COIL | 24182.77 |
CORE_TOP VAV BOX REHEAT COIL | 25546.82 |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | 5379.21 |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | 4103.19 |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | 5395.05 |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | 4771.46 |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | 5379.18 |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | 3681.59 |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | 5362.78 |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | 3930.62 |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | 5084.80 |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | 3894.15 |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | 5101.52 |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | 4198.47 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PACU_VAV_BOT | 2.49 | 1.31 | 4.98 | 1.31 | 4.58 | 4.58 | 0.300000 | 0.286194 | 4.58 |
PACU_VAV_MID | 2.15 | 1.27 | 4.30 | 1.27 | 3.84 | 3.84 | 0.300000 | 0.331365 | 3.84 |
PACU_VAV_TOP | 2.42 | 1.35 | 4.83 | 1.35 | 4.64 | 4.64 | 0.300000 | 0.291762 | 4.64 |
Maximum Outdoor Air Flow Rate [m3/s] | |
PACU_VAV_BOT_OA_CONTROLLER | 4.58 |
PACU_VAV_MID_OA_CONTROLLER | 3.84 |
PACU_VAV_TOP_OA_CONTROLLER | 4.64 |
Design Size High Speed Rated Air Flow Rate [m3/s] | Design Size High Speed Gross Rated Total Cooling Capacity [W] | Design Size High Speed Rated Sensible Heat Ratio | Design Size Low Speed Rated Air Flow Rate [m3/s] | Design Size Low Speed Gross Rated Total Cooling Capacity [W] | Design Size Low Speed Gross Rated Sensible Heat Ratio | |
PACU_VAV_BOT COOLING COIL | 4.58 | 113842.41 | 0.701083 | 1.53 | 37943.68 | 0.701083 |
PACU_VAV_MID COOLING COIL | 3.84 | 95319.58 | 0.701083 | 1.28 | 31770.02 | 0.701083 |
PACU_VAV_TOP COOLING COIL | 4.64 | 115228.53 | 0.701083 | 1.55 | 38405.67 | 0.701083 |
Design Size Nominal Capacity [W] | |
PACU_VAV_BOT HEATING COIL | 21291.30 |
PACU_VAV_MID HEATING COIL | 17827.08 |
PACU_VAV_TOP HEATING COIL | 21550.54 |
Design Size Maximum Flow Rate [m3/s] | |
PACU_VAV_BOT FAN | 4.58 |
PACU_VAV_MID FAN | 3.84 |
PACU_VAV_TOP FAN | 4.64 |
Design Size Nominal Supply Air Flow Rate [m3/s] | |
PACU_VAV_MID OA HEAT RECOVERY | 1.20 |
Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
SWHSYS1 | 0.000054 | 0.006435 |
Design Flow Rate [m3/s] | Design Power Consumption [W] | |
SWHSYS1 PUMP | 0.000054 | 0.726125 |
Use Side Design Flow Rate [m3/s] | |
SWHSYS1 WATER HEATER | 0.000054 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
PERIMETER_TOP_ZN_3_WALL_NORTH | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | |
PERIMETER_TOP_ZN_2_WALL_EAST | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | |
PERIMETER_TOP_ZN_1_WALL_SOUTH | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | |
PERIMETER_TOP_ZN_4_WALL_WEST | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | |
PERIMETER_BOT_ZN_3_WALL_NORTH | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | |
PERIMETER_BOT_ZN_2_WALL_EAST | PERIMETER_BOT_ZN_2_WALL_EAST_DOOR | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | |
PERIMETER_BOT_ZN_1_WALL_SOUTH | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | |
PERIMETER_BOT_ZN_4_WALL_WEST | PERIMETER_BOT_ZN_4_WALL_WEST_DOOR | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | |
PERIMETER_MID_ZN_3_WALL_NORTH | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | |
PERIMETER_MID_ZN_2_WALL_EAST | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | |
PERIMETER_MID_ZN_1_WALL_SOUTH | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | |
PERIMETER_MID_ZN_4_WALL_WEST | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
VersionVersion ID | |
1 | 22.1 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 26.90 | 26.70 | 26.00 | 26.40 | 27.50 | 28.30 | 29.20 | 29.00 | 28.90 | 27.20 | 27.50 | 27.60 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | Ho Chi Minh City-Tan Son Nhat Intl AP - VNM IWEC2 WMO#=489000 | 10.82 | 106.67 | 7.00 | 5.00 | 101265 | 1.2036 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 27.60 | 3.20 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | OfficeMedium | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 18 | 167 | 24 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | CORE_BOTTOM | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 1.37 | 1 | 1 | 1 | 4.57 | 45.34 | 4.57 | 28.70 | 0.00 | 2.74 | 2.74 | 2698.04 | TARP | TARP | 983.54 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
2 | TOPFLOOR_PLENUM | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 11.28 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 33.27 | 10.67 | 11.89 | 1.22 | 2024.76 | TARP | TARP | 1660.73 | 202.84 | 202.84 | 0.00 | 10 | 0 | 0 | No |
3 | MIDFLOOR_PLENUM | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 7.32 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 33.27 | 6.71 | 7.92 | 1.22 | 2024.76 | TARP | TARP | 1660.73 | 202.84 | 202.84 | 0.00 | 14 | 0 | 0 | No |
4 | FIRSTFLOOR_PLENUM | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 3.35 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 33.27 | 2.74 | 3.96 | 1.22 | 2024.76 | TARP | TARP | 1660.73 | 202.84 | 202.84 | 0.00 | 14 | 0 | 0 | No |
5 | CORE_MID | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 5.33 | 1 | 1 | 1 | 4.57 | 45.34 | 4.57 | 28.70 | 3.96 | 6.71 | 2.74 | 2698.04 | TARP | TARP | 983.54 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
6 | CORE_TOP | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 9.30 | 1 | 1 | 1 | 4.57 | 45.34 | 4.57 | 28.70 | 7.92 | 10.67 | 2.74 | 2698.04 | TARP | TARP | 983.54 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
7 | PERIMETER_TOP_ZN_3 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 31.11 | 9.30 | 1 | 1 | 1 | 0.00 | 49.91 | 28.70 | 33.27 | 7.92 | 10.67 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 77.59 | 59.33 | 6 | 1 | 0 | Yes |
8 | PERIMETER_TOP_ZN_2 | 0.0 | 0.00 | 0.00 | 0.00 | 47.82 | 16.64 | 9.30 | 1 | 1 | 1 | 45.34 | 49.91 | 0.00 | 33.27 | 7.92 | 10.67 | 2.74 | 360.08 | TARP | TARP | 131.26 | 91.28 | 51.72 | 39.55 | 6 | 1 | 0 | Yes |
9 | PERIMETER_TOP_ZN_1 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 2.16 | 9.30 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 4.57 | 7.92 | 10.67 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 77.59 | 59.33 | 6 | 1 | 0 | Yes |
10 | PERIMETER_TOP_ZN_4 | 0.0 | 0.00 | 0.00 | 0.00 | 2.09 | 16.64 | 9.30 | 1 | 1 | 1 | 0.00 | 4.57 | 0.00 | 33.27 | 7.92 | 10.67 | 2.74 | 360.05 | TARP | TARP | 131.25 | 91.28 | 51.72 | 39.55 | 6 | 1 | 0 | Yes |
11 | PERIMETER_BOT_ZN_3 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 31.11 | 1.37 | 1 | 1 | 1 | 0.00 | 49.91 | 28.70 | 33.27 | 0.00 | 2.74 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 73.69 | 59.33 | 6 | 5 | 0 | Yes |
12 | PERIMETER_BOT_ZN_2 | 0.0 | 0.00 | 0.00 | 0.00 | 47.82 | 16.64 | 1.37 | 1 | 1 | 1 | 45.34 | 49.91 | 0.00 | 33.27 | 0.00 | 2.74 | 2.74 | 360.08 | TARP | TARP | 131.26 | 91.28 | 49.77 | 39.55 | 6 | 3 | 0 | Yes |
13 | PERIMETER_BOT_ZN_1 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 2.16 | 1.37 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 4.57 | 0.00 | 2.74 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 73.69 | 59.33 | 6 | 5 | 0 | Yes |
14 | PERIMETER_BOT_ZN_4 | 0.0 | 0.00 | 0.00 | 0.00 | 2.09 | 16.64 | 1.37 | 1 | 1 | 1 | 0.00 | 4.57 | 0.00 | 33.27 | 0.00 | 2.74 | 2.74 | 360.05 | TARP | TARP | 131.25 | 91.28 | 49.77 | 39.55 | 6 | 3 | 0 | Yes |
15 | PERIMETER_MID_ZN_3 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 31.11 | 5.33 | 1 | 1 | 1 | 0.00 | 49.91 | 28.70 | 33.27 | 3.96 | 6.71 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 77.59 | 59.33 | 6 | 1 | 0 | Yes |
16 | PERIMETER_MID_ZN_2 | 0.0 | 0.00 | 0.00 | 0.00 | 47.82 | 16.64 | 5.33 | 1 | 1 | 1 | 45.34 | 49.91 | 0.00 | 33.27 | 3.96 | 6.71 | 2.74 | 360.08 | TARP | TARP | 131.26 | 91.28 | 51.72 | 39.55 | 6 | 1 | 0 | Yes |
17 | PERIMETER_MID_ZN_1 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 2.16 | 5.33 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 4.57 | 3.96 | 6.71 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 77.59 | 59.33 | 6 | 1 | 0 | Yes |
18 | PERIMETER_MID_ZN_4 | 0.0 | 0.00 | 0.00 | 0.00 | 2.09 | 16.64 | 5.33 | 1 | 1 | 1 | 0.00 | 4.57 | 0.00 | 33.27 | 3.96 | 6.71 | 2.74 | 360.05 | TARP | TARP | 131.25 | 91.28 | 51.72 | 39.55 | 6 | 1 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | CORE_BOTTOM | 983.54 | 52.9 | 18.579 | 5.382E-002 | 5.932 | 24.834 | 0.000 | 0.000 | 0.000 | 0.000 | 30.766 | No |
2 | TOPFLOOR_PLENUM | 1660.73 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
3 | MIDFLOOR_PLENUM | 1660.73 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
4 | FIRSTFLOOR_PLENUM | 1660.73 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
5 | CORE_MID | 983.54 | 52.9 | 18.579 | 5.382E-002 | 5.932 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
6 | CORE_TOP | 983.54 | 52.9 | 18.579 | 5.382E-002 | 5.932 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
7 | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 5.932 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
8 | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 18.579 | 5.382E-002 | 5.932 | 8.069 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
9 | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 5.932 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
10 | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 18.579 | 5.382E-002 | 5.932 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
11 | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 5.932 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
12 | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 18.579 | 5.382E-002 | 5.932 | 8.069 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
13 | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 5.932 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
14 | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 18.579 | 5.382E-002 | 5.932 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
15 | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 5.932 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
16 | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 18.579 | 5.382E-002 | 5.932 | 8.069 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
17 | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 5.932 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
18 | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 18.579 | 5.382E-002 | 5.932 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | Cooling Effect Calculation | Ankle Draft Calculation | |
1 | CORE_BOTTOM | BLDG_OCC_SCH_WO_SB | CORE_BOTTOM | 983.54 | 52.9 | 52.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 53 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
2 | CORE_MID | BLDG_OCC_SCH_WO_SB | CORE_MID | 983.54 | 52.9 | 52.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 53 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
3 | CORE_TOP | BLDG_OCC_SCH_WO_SB | CORE_TOP | 983.54 | 52.9 | 52.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 53 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
4 | PERIMETER_TOP_ZN_3 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
5 | PERIMETER_TOP_ZN_2 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
6 | PERIMETER_TOP_ZN_1 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
7 | PERIMETER_TOP_ZN_4 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
8 | PERIMETER_BOT_ZN_3 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
9 | PERIMETER_BOT_ZN_2 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
10 | PERIMETER_BOT_ZN_1 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
11 | PERIMETER_BOT_ZN_4 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
12 | PERIMETER_MID_ZN_3 | BLDG_OCC_SCH_WO_SB | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
13 | PERIMETER_MID_ZN_2 | BLDG_OCC_SCH_W_SB | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
14 | PERIMETER_MID_ZN_1 | BLDG_OCC_SCH_WO_SB | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
15 | PERIMETER_MID_ZN_4 | BLDG_OCC_SCH_WO_SB | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | CORE_BOTTOM_LIGHTS | LTG_SCH_OFFICE | CORE_BOTTOM | 983.54 | 52.9 | 5834.488 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 5834.488 |
2 | CORE_MID_LIGHTS | LTG_SCH_OFFICE | CORE_MID | 983.54 | 52.9 | 5834.488 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 5834.488 |
3 | CORE_TOP_LIGHTS | LTG_SCH_OFFICE | CORE_TOP | 983.54 | 52.9 | 5834.488 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 5834.488 |
4 | PERIMETER_TOP_ZN_3_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 1229.961 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1229.961 |
5 | PERIMETER_TOP_ZN_2_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 778.667 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 778.667 |
6 | PERIMETER_TOP_ZN_1_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 1229.961 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1229.961 |
7 | PERIMETER_TOP_ZN_4_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 778.616 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 778.616 |
8 | PERIMETER_BOT_ZN_3_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 1229.961 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1229.961 |
9 | PERIMETER_BOT_ZN_2_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 778.667 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 778.667 |
10 | PERIMETER_BOT_ZN_1_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 1229.961 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1229.961 |
11 | PERIMETER_BOT_ZN_4_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 778.616 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 778.616 |
12 | PERIMETER_MID_ZN_3_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 1229.961 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1229.961 |
13 | PERIMETER_MID_ZN_2_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 778.667 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 778.667 |
14 | PERIMETER_MID_ZN_1_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 1229.961 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1229.961 |
15 | PERIMETER_MID_ZN_4_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 778.616 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 778.616 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | CORE_BOTTOM_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_BOTTOM | 983.54 | 52.9 | 7937.156 | 8.070 | 149.931 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 7937.156 |
2 | CORE_MID_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_MID | 983.54 | 52.9 | 7937.156 | 8.070 | 149.931 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 7937.156 |
3 | CORE_TOP_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_TOP | 983.54 | 52.9 | 7937.156 | 8.070 | 149.931 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 7937.156 |
4 | PERIMETER_TOP_ZN_3_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 1673.214 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.214 |
5 | PERIMETER_TOP_ZN_2_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 1059.217 | 8.069 | 149.921 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.217 |
6 | PERIMETER_TOP_ZN_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 1673.203 | 8.070 | 149.929 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.203 |
7 | PERIMETER_TOP_ZN_4_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 1059.210 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.210 |
8 | PERIMETER_BOT_ZN_3_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 1673.214 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.214 |
9 | PERIMETER_BOT_ZN_2_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 1059.217 | 8.069 | 149.921 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.217 |
10 | PERIMETER_BOT_ZN_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 1673.203 | 8.070 | 149.929 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.203 |
11 | PERIMETER_BOT_ZN_4_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 1059.210 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.210 |
12 | PERIMETER_MID_ZN_3_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 1673.214 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.214 |
13 | PERIMETER_MID_ZN_2_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 1059.217 | 8.069 | 149.921 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.217 |
14 | PERIMETER_MID_ZN_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 1673.203 | 8.070 | 149.929 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.203 |
15 | PERIMETER_MID_ZN_4_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 1059.210 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.210 |
16 | CORE_BOTTOM_ELEVATORS_EQUIP | BLDG_ELEVATORS | CORE_BOTTOM | 983.54 | 52.9 | 16363.220 | 16.637 | 309.098 | 0.000 | 0.500 | 0.000 | 0.500 | ElevatorLift | 1963.586 | 11290.622 |
17 | ELEVATORS_LIGHTS_FAN | ELEV_LIGHT_FAN_SCH_ADD_DF | CORE_BOTTOM | 983.54 | 52.9 | 125.000 | 0.127 | 2.361 | 0.000 | 0.500 | 0.000 | 0.500 | ElevatorLightsFan | 0.000 | 86.250 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 2.101 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | INTERIORFURNISHINGS | 2 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
3 | DROPCEILING | 4 | 1 | 3 | 0.167 | 4.488 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
4 | INT_WALL | 7 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | INT_SLAB_FLOOR | 12 | 2 | 7 | 0.167 | 3.839 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
6 | INT_SLAB_CEILING | 13 | 2 | 7 | 0.167 | 3.839 | 0.900 | 0.900 | 0.700 | 0.700 | VeryRough |
7 | NONRES_ROOF | 17 | 3 | 3 | 0.167 | 0.2832 | 0.750 | 0.900 | 0.450 | 0.700 | Rough |
8 | NONRES_EXT_WALL_GRD | 20 | 4 | 7 | 0.167 | 1.029 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
9 | NONRES_EXT_WALL_MID | 21 | 4 | 7 | 0.167 | 1.013 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
10 | NONRES_EXT_WALL_TOP | 22 | 4 | 6 | 0.167 | 1.375 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
11 | PERIMETER_BOT_ZN_1_FLOOR_FFACTOR | 39 | 2 | 7 | 0.167 | 0.3192 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
12 | PERIMETER_BOT_ZN_2_FLOOR_FFACTOR | 40 | 2 | 7 | 0.167 | 0.3371 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
13 | PERIMETER_BOT_ZN_3_FLOOR_FFACTOR | 41 | 2 | 7 | 0.167 | 0.3192 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
14 | PERIMETER_BOT_ZN_4_FLOOR_FFACTOR | 42 | 2 | 7 | 0.167 | 0.3371 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
15 | CORE_BOT_ZN_5_FLOOR_FFACTOR | 43 | 2 | 8 | 0.167 | 0.5650E-02 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.4760 |
2 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
3 | AC02 ACOUSTIC CEILING | 0.0127 | 0.057 | 288.000 | 1339.000 | 0.2228 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
6 | 100MM NORMALWEIGHT CONCRETE FLOOR | 0.1016 | 2.310 | 2322.000 | 832.000 | 0.4398E-01 |
7 | CP02 CARPET PAD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2165 |
8 | CP02 CARPET PAD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2165 |
9 | 100MM NORMALWEIGHT CONCRETE FLOOR | 0.1016 | 2.310 | 2322.000 | 832.000 | 0.4398E-01 |
10 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
11 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 3.472 |
12 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
13 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
14 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
15 | NONRES_EXTERIOR_WALL_INSULATION_GRD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.7377 |
16 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
17 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
18 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
19 | NONRES_EXTERIOR_WALL_INSULATION_MID | 0.0000 | 0.000 | 0.000 | 0.000 | 0.7531 |
20 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
21 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
22 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
23 | NONRES_EXTERIOR_WALL_INSULATION_TOP | 0.0000 | 0.000 | 0.000 | 0.000 | 0.4931 |
24 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
25 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.056 |
26 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
27 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 2.890 |
28 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
29 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.056 |
30 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
31 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 2.890 |
32 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
33 | ~FC_Insulation_5 | 0.0000 | 0.000 | 0.000 | 0.000 | 176.9 |
34 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 2.1009573 | 2.1009573 | 2.1009573 | |
3 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
4 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
5 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
6 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
7 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
8 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
9 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
10 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
11 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
12 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
13 | 3 | -0.21589802E-09 | 0.15643069E-09 | -0.21589802E-09 | 0.12999471E-21 |
14 | 2 | 0.50772448E-02 | 0.30006816E-02 | 0.50772448E-02 | -0.13693132E-08 |
15 | 1 | -2.5944910 | 1.4597758 | -2.5944910 | 0.76344767E-02 |
16 | 0 | 7.0433378 | 2.9911476 | 7.0433378 | |
17 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
18 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
19 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
20 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
21 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
22 | 7 | 0.43260499E-16 | 0.34524919E-16 | 0.52793240E-17 | 0.0000000 |
23 | 6 | 0.69434179E-09 | 0.98085174E-11 | 0.18162501E-10 | -0.40870994E-12 |
24 | 5 | -0.12888762E-04 | 0.28373718E-06 | -0.16918523E-06 | 0.92361873E-08 |
25 | 4 | 0.25174112E-01 | 0.33697681E-03 | 0.22646198E-03 | -0.31467795E-04 |
26 | 3 | -3.7600775 | 0.27170599E-01 | -0.48495626E-01 | 0.94171705E-02 |
27 | 2 | 51.553741 | 0.22121684 | 1.2284947 | -0.25833933 |
28 | 1 | -128.86110 | 0.21944682 | -5.1479470 | 1.1228340 |
29 | 0 | 81.526494 | 0.16043334E-01 | 4.4519351 | |
30 | 7 | 0.52793240E-17 | 0.34524919E-16 | 0.43260499E-16 | 0.0000000 |
31 | 6 | 0.18162501E-10 | 0.98085174E-11 | 0.69434179E-09 | -0.40870994E-12 |
32 | 5 | -0.16918523E-06 | 0.28373718E-06 | -0.12888762E-04 | 0.92361873E-08 |
33 | 4 | 0.22646198E-03 | 0.33697681E-03 | 0.25174112E-01 | -0.31467795E-04 |
34 | 3 | -0.48495626E-01 | 0.27170599E-01 | -3.7600775 | 0.94171705E-02 |
35 | 2 | 1.2284947 | 0.22121684 | 51.553741 | -0.25833933 |
36 | 1 | -5.1479470 | 0.21944682 | -128.86110 | 1.1228340 |
37 | 0 | 4.4519351 | 0.16043334E-01 | 81.526494 | |
38 | 3 | -0.61927053E-06 | 0.12767249E-08 | -0.37968499E-05 | 0.16832131E-17 |
39 | 2 | 0.77611055 | 0.17315568E-02 | 1.0534842 | -0.72792597E-06 |
40 | 1 | -21.915918 | 0.11588205 | -6.3286394 | 0.20197014 |
41 | 0 | 21.365777 | 0.10835518 | 5.5011278 | |
42 | 7 | -0.27613173E-12 | 0.13648587E-14 | -0.80406974E-13 | 0.78369587E-16 |
43 | 6 | 0.25651297E-07 | 0.27955499E-09 | 0.59014154E-08 | -0.11905989E-12 |
44 | 5 | -0.17465063E-03 | 0.24416492E-05 | -0.90019538E-04 | 0.58421144E-08 |
45 | 4 | 0.27387862 | 0.12098825E-02 | 0.93122264E-01 | -0.31012301E-04 |
46 | 3 | -6.9041115 | 0.38080793E-01 | -2.2314619 | 0.27235146E-01 |
47 | 2 | 39.676056 | 0.13726811 | 14.823303 | -0.32003278 |
48 | 1 | -79.629469 | 0.62686726E-01 | -28.745292 | 1.0590931 |
49 | 0 | 46.824345 | 0.12759187E-02 | 16.300942 | |
50 | 7 | -0.27182421E-12 | 0.13107754E-14 | -0.81108189E-13 | 0.79120162E-16 |
51 | 6 | 0.25844325E-07 | 0.27588229E-09 | 0.59440225E-08 | -0.12008605E-12 |
52 | 5 | -0.17564658E-03 | 0.24062150E-05 | -0.90521036E-04 | 0.58837691E-08 |
53 | 4 | 0.27506755 | 0.11908598E-02 | 0.93548701E-01 | -0.31177608E-04 |
54 | 3 | -6.9277136 | 0.37441415E-01 | -2.2384615 | 0.27350651E-01 |
55 | 2 | 39.753961 | 0.13483533 | 14.852153 | -0.32090009 |
56 | 1 | -79.689237 | 0.61525268E-01 | -28.771196 | 1.0603666 |
57 | 0 | 46.824344 | 0.12512697E-02 | 16.300293 | |
58 | 6 | 0.21465343E-07 | 0.35044740E-09 | 0.49771822E-08 | -0.96989815E-13 |
59 | 5 | -0.15274237E-03 | 0.31655188E-05 | -0.78941554E-04 | 0.49363227E-08 |
60 | 4 | 0.24727258 | 0.16154212E-02 | 0.83601931E-01 | -0.27359285E-04 |
61 | 3 | -6.3748395 | 0.52179222E-01 | -2.0745682 | 0.24648141E-01 |
62 | 2 | 37.927790 | 0.19236366 | 14.173893 | -0.30057625 |
63 | 1 | -78.286849 | 0.89555956E-01 | -28.161423 | 1.0304865 |
64 | 0 | 46.824354 | 0.18576719E-02 | 16.316151 | |
65 | 7 | -0.13059908E-08 | -0.16504735E-15 | 0.90649122E-14 | -0.12541312E-15 |
66 | 6 | 0.89164571E-05 | 0.61445766E-08 | 0.31804070E-02 | -0.26679919E-04 |
67 | 5 | -0.64531733E-03 | 0.36428408E-05 | -0.22318667 | 0.19514025E-02 |
68 | 4 | 0.14868215E-01 | 0.16589759E-03 | 4.8205855 | -0.45178851E-01 |
69 | 3 | -0.13063200 | 0.13198961E-02 | -37.970795 | 0.39809422 |
70 | 2 | 0.46393162 | 0.21965806E-02 | 116.38542 | -1.4166214 |
71 | 1 | -0.66966470 | 0.66967549E-03 | -143.84930 | 2.0480865 |
72 | 0 | 0.32650513 | 0.16166393E-04 | 60.838472 | |
73 | 7 | -0.12346633E-08 | -0.14425327E-15 | 0.91357699E-14 | -0.10087110E-15 |
74 | 6 | 0.94177090E-05 | 0.64929528E-08 | 0.31789869E-02 | -0.26668006E-04 |
75 | 5 | -0.68205191E-03 | 0.38502154E-05 | -0.22310594 | 0.19506899E-02 |
76 | 4 | 0.15716902E-01 | 0.17535208E-03 | 4.8192406 | -0.45165923E-01 |
77 | 3 | -0.13809356 | 0.13952366E-02 | -37.963195 | 0.39801023 |
78 | 2 | 0.49043520 | 0.23220647E-02 | 116.37063 | -1.4164235 |
79 | 1 | -0.70792287 | 0.70803996E-03 | -143.84059 | 2.0479434 |
80 | 0 | 0.34515858 | 0.17069463E-04 | 60.838472 | |
81 | 7 | -0.13059908E-08 | -0.16504702E-15 | 0.90649122E-14 | -0.12541312E-15 |
82 | 6 | 0.89164571E-05 | 0.61445766E-08 | 0.31804070E-02 | -0.26679919E-04 |
83 | 5 | -0.64531733E-03 | 0.36428408E-05 | -0.22318667 | 0.19514025E-02 |
84 | 4 | 0.14868215E-01 | 0.16589759E-03 | 4.8205855 | -0.45178851E-01 |
85 | 3 | -0.13063200 | 0.13198961E-02 | -37.970795 | 0.39809422 |
86 | 2 | 0.46393162 | 0.21965806E-02 | 116.38542 | -1.4166214 |
87 | 1 | -0.66966470 | 0.66967549E-03 | -143.84930 | 2.0480865 |
88 | 0 | 0.32650513 | 0.16166393E-04 | 60.838472 | |
89 | 7 | -0.12345751E-08 | -0.14398051E-15 | 0.92894684E-14 | -0.10085648E-15 |
90 | 6 | 0.94183649E-05 | 0.64934092E-08 | 0.31789851E-02 | -0.26667991E-04 |
91 | 5 | -0.68209995E-03 | 0.38504865E-05 | -0.22310583 | 0.19506890E-02 |
92 | 4 | 0.15718012E-01 | 0.17536444E-03 | 4.8192388 | -0.45165906E-01 |
93 | 3 | -0.13810332 | 0.13953351E-02 | -37.963185 | 0.39801012 |
94 | 2 | 0.49046985 | 0.23222288E-02 | 116.37061 | -1.4164232 |
95 | 1 | -0.70797289 | 0.70809005E-03 | -143.84058 | 2.0479432 |
96 | 0 | 0.34518296 | 0.17070678E-04 | 60.838472 | |
97 | 8 | 0.57026216E-10 | -0.29656739E-13 | 0.26072253E-13 | -0.16907584E-15 |
98 | 7 | -0.80728763E-07 | 0.14958947E-11 | -0.10196182E-04 | 0.85534123E-07 |
99 | 6 | 0.59163330E-05 | 0.23390251E-08 | 0.39199948E-02 | -0.33137873E-04 |
100 | 5 | -0.14678961E-03 | 0.29443049E-06 | -0.24001665 | 0.21083805E-02 |
101 | 4 | 0.15257864E-02 | 0.63469284E-05 | 4.9653291 | -0.46676227E-01 |
102 | 3 | -0.74362311E-02 | 0.30151767E-04 | -38.474208 | 0.40407555 |
103 | 2 | 0.17883035E-01 | 0.32406056E-04 | 117.10039 | -1.4265819 |
104 | 1 | -0.20235698E-01 | 0.62001922E-05 | -144.19380 | 2.0537490 |
105 | 0 | 0.84795330E-02 | 0.69040512E-07 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | Conductance (Before Adjusted) {W/m2-K} | Convection Coefficient Adjustment Ratio | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | WINDOW_U_0.5037_SHGC_EAST_0.23 | 35 | 1 | VerySmooth | 2.864 | 2.864 | 1.000 | 0.231 | ||
2 | WINDOW_U_0.5037_SHGC_SOUTH_0.23 | 36 | 1 | VerySmooth | 2.864 | 2.864 | 1.000 | 0.231 | ||
3 | WINDOW_U_0.5037_SHGC_WEST_0.23 | 37 | 1 | VerySmooth | 2.864 | 2.864 | 1.000 | 0.231 | ||
4 | WINDOW_U_0.5037_SHGC_NORTH_0.23 | 38 | 1 | VerySmooth | 2.864 | 2.864 | 1.000 | 0.231 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | GLAZING LAYER EAST | SpectralAverage | 1.92411E-002 | 0.14129 | 0.63052 | 0.63052 | 0.23000 | 0.16588 | 0.25006 | 0.00000 | 0.84000 | 0.84000 | 0.10752 | 1.00000 | No | |
2 | GLAZING LAYER SOUTH | SpectralAverage | 1.92411E-002 | 0.14129 | 0.63052 | 0.63052 | 0.23000 | 0.16588 | 0.25006 | 0.00000 | 0.84000 | 0.84000 | 0.10752 | 1.00000 | No | |
3 | GLAZING LAYER WEST | SpectralAverage | 1.92411E-002 | 0.14129 | 0.63052 | 0.63052 | 0.23000 | 0.16588 | 0.25006 | 0.00000 | 0.84000 | 0.84000 | 0.10752 | 1.00000 | No | |
4 | GLAZING LAYER NORTH | SpectralAverage | 1.92411E-002 | 0.14129 | 0.63052 | 0.63052 | 0.23000 | 0.16588 | 0.25006 | 0.00000 | 0.84000 | 0.84000 | 0.10752 | 1.00000 | No |
Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | PolygonClipping | Periodic | 30 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
Enclosure Name | Number of Exterior Windows | Number of Exterior Windows in Adjacent Enclosures | |
1 | PERIMETER_TOP_ZN_3 | 1 | 0 |
2 | PERIMETER_TOP_ZN_2 | 1 | 0 |
3 | PERIMETER_TOP_ZN_1 | 1 | 0 |
4 | PERIMETER_TOP_ZN_4 | 1 | 0 |
5 | PERIMETER_BOT_ZN_3 | 3 | 0 |
6 | PERIMETER_BOT_ZN_2 | 2 | 0 |
7 | PERIMETER_BOT_ZN_1 | 3 | 0 |
8 | PERIMETER_BOT_ZN_4 | 2 | 0 |
9 | PERIMETER_MID_ZN_3 | 1 | 0 |
10 | PERIMETER_MID_ZN_2 | 1 | 0 |
11 | PERIMETER_MID_ZN_1 | 1 | 0 |
12 | PERIMETER_MID_ZN_4 | 1 | 0 |
Enclosure Name | Number of Adjacent Enclosures with Windows | Adjacent Enclosure Names - 1st 100 (max) | |
1 | PERIMETER_TOP_ZN_3 | 0 | |
2 | PERIMETER_TOP_ZN_2 | 0 | |
3 | PERIMETER_TOP_ZN_1 | 0 | |
4 | PERIMETER_TOP_ZN_4 | 0 | |
5 | PERIMETER_BOT_ZN_3 | 0 | |
6 | PERIMETER_BOT_ZN_2 | 0 | |
7 | PERIMETER_BOT_ZN_1 | 0 | |
8 | PERIMETER_BOT_ZN_4 | 0 | |
9 | PERIMETER_MID_ZN_3 | 0 | |
10 | PERIMETER_MID_ZN_2 | 0 | |
11 | PERIMETER_MID_ZN_1 | 0 | |
12 | PERIMETER_MID_ZN_4 | 0 |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | 0.3785 | 29307.1 | 1.024 | 0.2440 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | CORE_BOT_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
2 | CORE_BOT_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
3 | CORE_BOT_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
4 | CORE_BOT_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
5 | CORE_BOT_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
6 | CORE_BOT_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
7 | CORE_BOTTOM_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
8 | PERIMETER_TOP_PLENUM_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
9 | PERIMETER_TOP_PLENUM_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
10 | PERIMETER_TOP_PLENUM_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
11 | PERIMETER_TOP_PLENUM_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
12 | iz-PERIMETER_TOP_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
13 | iz-PERIMETER_TOP_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
14 | iz-PERIMETER_TOP_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
15 | iz-PERIMETER_TOP_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
16 | iz-CORE_TOP_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
17 | BUILDING_ROOF | 0 | 1660.73 | 183.01 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
18 | PERIMETER_MID_PLENUM_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
19 | PERIMETER_MID_PLENUM_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
20 | PERIMETER_MID_PLENUM_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
21 | PERIMETER_MID_PLENUM_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
22 | iz-PERIMETER_MID_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
23 | iz-PERIMETER_MID_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
24 | iz-PERIMETER_MID_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
25 | iz-PERIMETER_MID_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
26 | iz-CORE_MID_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
27 | iz-PERIMETER_TOP_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
28 | iz-PERIMETER_TOP_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
29 | iz-PERIMETER_TOP_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
30 | iz-PERIMETER_TOP_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
31 | iz-CORE_TOP_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
32 | PERIMETER_BOT_PLENUM_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
33 | PERIMETER_BOT_PLENUM_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
34 | PERIMETER_BOT_PLENUM_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
35 | PERIMETER_BOT_PLENUM_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
36 | iz-PERIMETER_BOT_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
37 | iz-PERIMETER_BOT_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
38 | iz-PERIMETER_BOT_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
39 | iz-PERIMETER_BOT_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
40 | iz-CORE_BOT_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
41 | iz-PERIMETER_MID_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
42 | iz-PERIMETER_MID_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
43 | iz-PERIMETER_MID_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
44 | iz-PERIMETER_MID_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
45 | iz-CORE_MID_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
46 | CORE_MID_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
47 | CORE_MID_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
48 | CORE_MID_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
49 | CORE_MID_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
50 | CORE_MID_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
51 | CORE_MID_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
52 | CORE_MID_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
53 | CORE_TOP_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
54 | CORE_TOP_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
55 | CORE_TOP_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
56 | CORE_TOP_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
57 | CORE_TOP_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
58 | CORE_TOP_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
59 | CORE_TOP_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
60 | PERIMETER_TOP_ZN_3_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 3 | No | No |
61 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
62 | PERIMETER_TOP_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
63 | iz-PERIMETER_TOP_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
64 | iz-CORE_TOP_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
65 | PERIMETER_TOP_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
66 | PERIMETER_TOP_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
67 | PERIMETER_TOP_ZN_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
68 | PERIMETER_TOP_ZN_2_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 3 | No | No |
69 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 2 | No | No |
70 | PERIMETER_TOP_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
71 | iz-PERIMETER_TOP_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
72 | iz-CORE_TOP_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
73 | PERIMETER_TOP_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
74 | PERIMETER_TOP_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
75 | PERIMETER_TOP_ZN_2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
76 | PERIMETER_TOP_ZN_1_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 3 | No | No |
77 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
78 | PERIMETER_TOP_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
79 | iz-PERIMETER_TOP_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
80 | iz-CORE_TOP_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
81 | PERIMETER_TOP_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
82 | PERIMETER_TOP_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
83 | PERIMETER_TOP_ZN_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
84 | PERIMETER_TOP_ZN_4_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 3 | No | No |
85 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 2 | No | No |
86 | PERIMETER_TOP_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
87 | iz-PERIMETER_TOP_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
88 | iz-CORE_TOP_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
89 | PERIMETER_TOP_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
90 | PERIMETER_TOP_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
91 | PERIMETER_TOP_ZN_4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
92 | PERIMETER_BOT_ZN_3_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 3 | No | No |
93 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
94 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
95 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
96 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
97 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
98 | PERIMETER_BOT_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
99 | iz-PERIMETER_BOT_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
100 | iz-CORE_BOT_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
101 | PERIMETER_BOT_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
102 | PERIMETER_BOT_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
103 | PERIMETER_BOT_ZN_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
104 | PERIMETER_BOT_ZN_2_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 3 | No | No |
105 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 2 | No | No |
106 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 2 | No | No |
107 | PERIMETER_BOT_ZN_2_WALL_EAST_DOOR | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
108 | PERIMETER_BOT_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
109 | iz-PERIMETER_BOT_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
110 | iz-CORE_BOT_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
111 | PERIMETER_BOT_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
112 | PERIMETER_BOT_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
113 | PERIMETER_BOT_ZN_2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
114 | PERIMETER_BOT_ZN_1_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 3 | No | No |
115 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
116 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
117 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
118 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
119 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
120 | PERIMETER_BOT_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
121 | iz-PERIMETER_BOT_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
122 | iz-CORE_BOT_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
123 | PERIMETER_BOT_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
124 | PERIMETER_BOT_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
125 | PERIMETER_BOT_ZN_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
126 | PERIMETER_BOT_ZN_4_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 3 | No | No |
127 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 2 | No | No |
128 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 2 | No | No |
129 | PERIMETER_BOT_ZN_4_WALL_WEST_DOOR | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
130 | PERIMETER_BOT_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
131 | iz-PERIMETER_BOT_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
132 | iz-CORE_BOT_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
133 | PERIMETER_BOT_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
134 | PERIMETER_BOT_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
135 | PERIMETER_BOT_ZN_4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
136 | PERIMETER_MID_ZN_3_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 3 | No | No |
137 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
138 | PERIMETER_MID_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
139 | iz-PERIMETER_MID_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
140 | iz-CORE_MID_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
141 | PERIMETER_MID_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
142 | PERIMETER_MID_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
143 | PERIMETER_MID_ZN_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
144 | PERIMETER_MID_ZN_2_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 3 | No | No |
145 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 2 | No | No |
146 | PERIMETER_MID_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
147 | iz-PERIMETER_MID_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
148 | iz-CORE_MID_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
149 | PERIMETER_MID_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
150 | PERIMETER_MID_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
151 | PERIMETER_MID_ZN_2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
152 | PERIMETER_MID_ZN_1_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 3 | No | No |
153 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
154 | PERIMETER_MID_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
155 | iz-PERIMETER_MID_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
156 | iz-CORE_MID_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
157 | PERIMETER_MID_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
158 | PERIMETER_MID_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
159 | PERIMETER_MID_ZN_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
160 | PERIMETER_MID_ZN_4_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 3 | No | No |
161 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 2 | No | No |
162 | PERIMETER_MID_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
163 | iz-PERIMETER_MID_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
164 | iz-CORE_MID_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
165 | PERIMETER_MID_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
166 | PERIMETER_MID_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
167 | PERIMETER_MID_ZN_4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | PERIMETER_TOP_ZN_3_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 1.950E-002 | 9.403E-005 | 1.424E-004 | 0.123 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | PERIMETER_TOP_ZN_2_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 1.300E-002 | 9.902E-005 | 1.424E-004 | 0.130 | 0.000 | 0.000 | 0.224 | 0.000 |
3 | PERIMETER_TOP_ZN_1_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 1.950E-002 | 9.403E-005 | 1.424E-004 | 0.123 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | PERIMETER_TOP_ZN_4_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 1.300E-002 | 9.902E-005 | 1.424E-004 | 0.130 | 0.000 | 0.000 | 0.224 | 0.000 |
5 | PERIMETER_BOT_ZN_3_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 1.950E-002 | 9.403E-005 | 1.384E-004 | 0.123 | 0.000 | 0.000 | 0.224 | 0.000 |
6 | PERIMETER_BOT_ZN_2_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 1.300E-002 | 9.902E-005 | 1.394E-004 | 0.130 | 0.000 | 0.000 | 0.224 | 0.000 |
7 | PERIMETER_BOT_ZN_1_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 1.950E-002 | 9.403E-005 | 1.384E-004 | 0.123 | 0.000 | 0.000 | 0.224 | 0.000 |
8 | PERIMETER_BOT_ZN_1_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 1.043 | 5.030E-003 | 7.407E-003 | 6.602 | 1.000 | 0.000 | 0.000 | 0.000 |
9 | PERIMETER_BOT_ZN_4_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 1.300E-002 | 9.902E-005 | 1.394E-004 | 0.130 | 0.000 | 0.000 | 0.224 | 0.000 |
10 | PERIMETER_MID_ZN_3_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 1.950E-002 | 9.403E-005 | 1.424E-004 | 0.123 | 0.000 | 0.000 | 0.224 | 0.000 |
11 | PERIMETER_MID_ZN_2_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 1.300E-002 | 9.902E-005 | 1.424E-004 | 0.130 | 0.000 | 0.000 | 0.224 | 0.000 |
12 | PERIMETER_MID_ZN_1_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 1.950E-002 | 9.403E-005 | 1.424E-004 | 0.123 | 0.000 | 0.000 | 0.224 | 0.000 |
13 | PERIMETER_MID_ZN_4_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 1.300E-002 | 9.902E-005 | 1.424E-004 | 0.130 | 0.000 | 0.000 | 0.224 | 0.000 |
14 | FIRSTFLOOR_PLENUM_INFILTRATION | INFIL_SCH_PNNL | FIRSTFLOOR_PLENUM | 1660.73 | 0.0 | 2.888E-002 | 1.739E-005 | 1.424E-004 | 5.135E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
15 | MIDFLOOR_PLENUM_INFILTRATION | INFIL_SCH_PNNL | MIDFLOOR_PLENUM | 1660.73 | 0.0 | 2.888E-002 | 1.739E-005 | 1.424E-004 | 5.135E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
16 | TOPFLOOR_PLENUM_INFILTRATION | INFIL_SCH_PNNL | TOPFLOOR_PLENUM | 1660.73 | 0.0 | 2.888E-002 | 1.739E-005 | 1.550E-005 | 5.135E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | CORE_BOTTOM | Mixing/Well-Stirred |
2 | TOPFLOOR_PLENUM | Mixing/Well-Stirred |
3 | MIDFLOOR_PLENUM | Mixing/Well-Stirred |
4 | FIRSTFLOOR_PLENUM | Mixing/Well-Stirred |
5 | CORE_MID | Mixing/Well-Stirred |
6 | CORE_TOP | Mixing/Well-Stirred |
7 | PERIMETER_TOP_ZN_3 | Mixing/Well-Stirred |
8 | PERIMETER_TOP_ZN_2 | Mixing/Well-Stirred |
9 | PERIMETER_TOP_ZN_1 | Mixing/Well-Stirred |
10 | PERIMETER_TOP_ZN_4 | Mixing/Well-Stirred |
11 | PERIMETER_BOT_ZN_3 | Mixing/Well-Stirred |
12 | PERIMETER_BOT_ZN_2 | Mixing/Well-Stirred |
13 | PERIMETER_BOT_ZN_1 | Mixing/Well-Stirred |
14 | PERIMETER_BOT_ZN_4 | Mixing/Well-Stirred |
15 | PERIMETER_MID_ZN_3 | Mixing/Well-Stirred |
16 | PERIMETER_MID_ZN_2 | Mixing/Well-Stirred |
17 | PERIMETER_MID_ZN_1 | Mixing/Well-Stirred |
18 | PERIMETER_MID_ZN_4 | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.0000 |
Sizing Factor ID | Value | |
1 | Global | 1.0000 |
Sky Type | MonthAndDay | Daylighting Control Name | Enclosure Name | Window Name | Reference Point | Daylight Factor | |
1 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 3.9257E-003 |
2 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 3.9583E-003 |
3 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 3.9690E-003 |
4 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 3.9963E-003 |
5 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 3.3740E-003 |
6 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 3.3930E-003 |
7 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 2.2338E-003 |
8 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 2.2473E-003 |
9 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 5.1573E-002 |
10 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 2.1872E-002 |
11 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 5.3382E-002 |
12 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 2.1411E-002 |
13 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 4.5780E-002 |
14 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 1.6963E-002 |
15 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 2.5814E-002 |
16 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 9.6580E-003 |
17 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 3.9251E-003 |
18 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 3.9561E-003 |
19 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 3.9683E-003 |
20 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 3.9940E-003 |
21 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 3.3734E-003 |
22 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 3.3909E-003 |
23 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 2.2337E-003 |
24 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 2.2471E-003 |
25 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 3.0364E-002 |
26 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 1.7646E-002 |
27 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 2.7031E-002 |
28 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 1.5396E-002 |
29 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 2.7094E-002 |
30 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 1.3487E-002 |
31 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 3.0059E-002 |
32 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 1.4048E-002 |
33 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 2.9007E-004 |
34 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 2.9116E-004 |
35 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 2.6531E-004 |
36 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 2.6611E-004 |
37 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 2.4899E-004 |
38 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 2.4928E-004 |
39 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 2.6073E-004 |
40 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 2.6119E-004 |
41 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.0957E-003 |
42 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.1234E-003 |
43 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 1.8082E-003 |
44 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.8298E-003 |
45 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 1.5406E-003 |
46 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.5527E-003 |
47 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.2337E-003 |
48 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.2471E-003 |
49 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 1.8988E-002 |
50 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.0572E-002 |
51 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 1.5163E-002 |
52 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 8.3133E-003 |
53 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 1.3116E-002 |
54 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 5.5526E-003 |
55 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.5814E-002 |
56 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 9.6580E-003 |
57 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.0960E-003 |
58 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.1239E-003 |
59 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 1.8086E-003 |
60 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.8306E-003 |
61 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 1.5411E-003 |
62 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.5542E-003 |
63 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.2338E-003 |
64 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.2473E-003 |
65 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 3.2307E-002 |
66 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 1.8482E-002 |
67 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 2.9270E-002 |
68 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 1.6354E-002 |
69 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 2.9218E-002 |
70 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 1.4397E-002 |
71 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 3.0059E-002 |
72 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 1.4048E-002 |
73 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 3.0284E-004 |
74 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 3.0463E-004 |
75 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 2.8025E-004 |
76 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 2.8192E-004 |
77 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 2.6248E-004 |
78 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 2.6351E-004 |
79 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 2.6074E-004 |
80 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 2.6120E-004 |
81 | Clear Sky | 12/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 5.5156E-002 |
82 | Clear Sky | 12/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 2.8037E-002 |
83 | Clear Turbid Sky | 12/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 5.6773E-002 |
84 | Clear Turbid Sky | 12/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 2.7664E-002 |
85 | Intermediate Sky | 12/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 4.9587E-002 |
86 | Intermediate Sky | 12/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 2.2424E-002 |
87 | Overcast Sky | 12/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 2.9043E-002 |
88 | Overcast Sky | 12/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 1.3460E-002 |
89 | Clear Sky | 12/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 2.9280E-002 |
90 | Clear Sky | 12/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 1.7043E-002 |
91 | Clear Turbid Sky | 12/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 2.6135E-002 |
92 | Clear Turbid Sky | 12/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 1.4903E-002 |
93 | Intermediate Sky | 12/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 2.6400E-002 |
94 | Intermediate Sky | 12/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 1.3115E-002 |
95 | Overcast Sky | 12/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 2.9340E-002 |
96 | Overcast Sky | 12/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 1.3660E-002 |
97 | Clear Sky | 12/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 2.1801E-002 |
98 | Clear Sky | 12/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 1.4050E-002 |
99 | Clear Turbid Sky | 12/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 1.7735E-002 |
100 | Clear Turbid Sky | 12/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 1.1396E-002 |
101 | Intermediate Sky | 12/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 1.5579E-002 |
102 | Intermediate Sky | 12/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 8.3176E-003 |
103 | Overcast Sky | 12/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 2.9043E-002 |
104 | Overcast Sky | 12/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 1.3460E-002 |
105 | Clear Sky | 12/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 3.1159E-002 |
106 | Clear Sky | 12/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 1.7840E-002 |
107 | Clear Turbid Sky | 12/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 2.8301E-002 |
108 | Clear Turbid Sky | 12/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 1.5816E-002 |
109 | Intermediate Sky | 12/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 2.8456E-002 |
110 | Intermediate Sky | 12/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 1.3983E-002 |
111 | Overcast Sky | 12/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 2.9340E-002 |
112 | Overcast Sky | 12/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 1.3660E-002 |
113 | Clear Sky | 12/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 5.5154E-002 |
114 | Clear Sky | 12/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 2.8034E-002 |
115 | Clear Turbid Sky | 12/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 5.6769E-002 |
116 | Clear Turbid Sky | 12/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 2.7661E-002 |
117 | Intermediate Sky | 12/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 4.9583E-002 |
118 | Intermediate Sky | 12/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 2.2422E-002 |
119 | Overcast Sky | 12/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 2.9041E-002 |
120 | Overcast Sky | 12/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 1.3459E-002 |
121 | Clear Sky | 12/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 2.9279E-002 |
122 | Clear Sky | 12/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 1.7042E-002 |
123 | Clear Turbid Sky | 12/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 2.6134E-002 |
124 | Clear Turbid Sky | 12/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 1.4902E-002 |
125 | Intermediate Sky | 12/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 2.6398E-002 |
126 | Intermediate Sky | 12/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 1.3113E-002 |
127 | Overcast Sky | 12/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 2.9337E-002 |
128 | Overcast Sky | 12/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 1.3658E-002 |
129 | Clear Sky | 12/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 2.1802E-002 |
130 | Clear Sky | 12/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 1.4049E-002 |
131 | Clear Turbid Sky | 12/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 1.7735E-002 |
132 | Clear Turbid Sky | 12/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 1.1396E-002 |
133 | Intermediate Sky | 12/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 1.5579E-002 |
134 | Intermediate Sky | 12/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 8.3169E-003 |
135 | Overcast Sky | 12/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 2.9041E-002 |
136 | Overcast Sky | 12/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 1.3459E-002 |
137 | Clear Sky | 12/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 3.1158E-002 |
138 | Clear Sky | 12/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 1.7839E-002 |
139 | Clear Turbid Sky | 12/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 2.8300E-002 |
140 | Clear Turbid Sky | 12/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 1.5815E-002 |
141 | Intermediate Sky | 12/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 2.8454E-002 |
142 | Intermediate Sky | 12/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 1.3981E-002 |
143 | Overcast Sky | 12/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 2.9338E-002 |
144 | Overcast Sky | 12/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 1.3659E-002 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | CORE_BOTTOM | Cooling | 37501.53500 | 37501.53500 | 2.70296 | 2.70296 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 08:00:00 | 28.91000 | 1.71462E-002 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
2 | CORE_BOTTOM | Heating | 0.00000 | 0.00000 | 0.00000 | 0.42469 | 00:10:00 | 20.10000 | 1.47983E-002 | 983.53657 | 52.93867 | 0.42469 | 0.00000 | |
3 | CORE_MID | Cooling | 27054.21619 | 27054.21619 | 1.94732 | 1.94732 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 08:00:00 | 28.91000 | 1.71462E-002 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
4 | CORE_MID | Heating | 1223.30208 | 1223.30208 | 5.20522E-002 | 0.42469 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 20.10000 | 1.47983E-002 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
5 | CORE_TOP | Cooling | 29489.31609 | 29489.31609 | 2.14359 | 2.14359 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:40:00 | 35.20000 | 1.71581E-002 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
6 | CORE_TOP | Heating | 5016.61274 | 5016.61274 | 0.21068 | 0.42469 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 20.10000 | 1.47983E-002 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
7 | PERIMETER_TOP_ZN_3 | Cooling | 9473.07353 | 9473.07353 | 0.68861 | 0.68861 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:20:00 | 35.03000 | 1.71578E-002 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
8 | PERIMETER_TOP_ZN_3 | Heating | 1614.92915 | 1614.92915 | 6.77748E-002 | 8.95286E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 20.10000 | 1.47983E-002 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
9 | PERIMETER_TOP_ZN_2 | Cooling | 8454.36508 | 8454.36508 | 0.61456 | 0.61456 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 09:50:00 | 31.72917 | 1.71515E-002 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
10 | PERIMETER_TOP_ZN_2 | Heating | 1046.85953 | 1046.85953 | 4.39425E-002 | 5.66790E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 20.10000 | 1.47983E-002 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
11 | PERIMETER_TOP_ZN_1 | Cooling | 9224.99095 | 9224.99095 | 0.67058 | 0.67058 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:50:00 | 35.20000 | 1.71581E-002 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
12 | PERIMETER_TOP_ZN_1 | Heating | 1650.54433 | 1650.54433 | 6.92807E-002 | 8.95286E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 20.10000 | 1.47983E-002 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
13 | PERIMETER_TOP_ZN_4 | Cooling | 9831.32357 | 9831.32357 | 0.71465 | 0.71465 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 16:10:00 | 34.57667 | 1.71570E-002 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
14 | PERIMETER_TOP_ZN_4 | Heating | 1046.82140 | 1046.82140 | 4.39409E-002 | 5.66753E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 20.10000 | 1.47983E-002 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
15 | PERIMETER_BOT_ZN_3 | Cooling | 7945.21023 | 7945.21023 | 0.57754 | 0.57754 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:20:00 | 35.03000 | 1.71578E-002 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
16 | PERIMETER_BOT_ZN_3 | Heating | 96.44827 | 96.44827 | 4.12795E-003 | 8.95286E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 20.10000 | 1.47983E-002 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
17 | PERIMETER_BOT_ZN_2 | Cooling | 7585.78215 | 7585.78215 | 0.55141 | 0.55141 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 09:40:00 | 31.48833 | 1.71511E-002 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
18 | PERIMETER_BOT_ZN_2 | Heating | 73.58043 | 73.58043 | 3.14830E-003 | 5.66790E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 20.10000 | 1.47983E-002 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
19 | PERIMETER_BOT_ZN_1 | Cooling | 7727.11411 | 7727.11411 | 0.56169 | 0.56169 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:30:00 | 35.20000 | 1.71581E-002 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
20 | PERIMETER_BOT_ZN_1 | Heating | 127.68146 | 127.68146 | 5.46178E-003 | 8.95286E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 20.10000 | 1.47983E-002 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
21 | PERIMETER_BOT_ZN_4 | Cooling | 8098.92401 | 8098.92401 | 0.58871 | 0.58871 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 16:30:00 | 34.35000 | 1.71565E-002 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
22 | PERIMETER_BOT_ZN_4 | Heating | 73.57833 | 73.57833 | 3.14821E-003 | 5.66753E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 20.10000 | 1.47983E-002 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
23 | PERIMETER_MID_ZN_3 | Cooling | 7937.05296 | 7937.05296 | 0.57696 | 0.57696 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:30:00 | 34.94500 | 1.71577E-002 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
24 | PERIMETER_MID_ZN_3 | Heating | 789.08578 | 789.08578 | 3.33842E-002 | 8.95286E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 20.10000 | 1.47983E-002 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
25 | PERIMETER_MID_ZN_2 | Cooling | 8023.69985 | 8023.69985 | 0.58325 | 0.58325 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 09:30:00 | 31.24750 | 1.71506E-002 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
26 | PERIMETER_MID_ZN_2 | Heating | 522.28310 | 522.28310 | 2.20944E-002 | 5.66790E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 20.10000 | 1.47983E-002 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
27 | PERIMETER_MID_ZN_1 | Cooling | 7728.93240 | 7728.93240 | 0.56183 | 0.56183 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:30:00 | 35.20000 | 1.71581E-002 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
28 | PERIMETER_MID_ZN_1 | Heating | 828.98766 | 828.98766 | 3.50549E-002 | 8.95286E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 20.10000 | 1.47983E-002 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
29 | PERIMETER_MID_ZN_4 | Cooling | 8650.73294 | 8650.73294 | 0.62883 | 0.62883 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 16:10:00 | 34.57667 | 1.71570E-002 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
30 | PERIMETER_MID_ZN_4 | Heating | 522.27319 | 522.27319 | 2.20940E-002 | 5.66753E-002 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 20.10000 | 1.47983E-002 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PACU_VAV_BOT | Cooling | Sensible | 77988.36 | 4.58443 | 4.58443 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 00:00:00 |
2 | PACU_VAV_BOT | Heating | Sensible | 0.00 | 0.00000 | 0.00000 | 00:00:00 | |
3 | PACU_VAV_MID | Cooling | Sensible | 67862.98 | 3.83852 | 3.83852 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 00:00:00 |
4 | PACU_VAV_MID | Heating | Sensible | 0.00 | 0.00000 | 0.00000 | 00:00:00 | |
5 | PACU_VAV_TOP | Cooling | Sensible | 78779.84 | 4.64025 | 4.64025 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 00:00:00 |
6 | PACU_VAV_TOP | Heating | Sensible | 0.00 | 0.00000 | 0.00000 | 00:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 2.70296 |
2 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.27727 |
3 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.28200 |
4 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.76223 |
5 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.73939 |
6 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
7 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.37410E-003 |
8 | Coil:Heating:Electric | CORE_BOTTOM VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 25445.72061 |
9 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 1.94732 |
10 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.38487 |
11 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.37200 |
12 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.72440 |
13 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
14 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
15 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 9.89956E-004 |
16 | Coil:Heating:Electric | CORE_MID VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 24182.77027 |
17 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 2.14359 |
18 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.34963 |
19 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.35700 |
20 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.76526 |
21 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.93234 |
22 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
23 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.08974E-003 |
24 | Coil:Heating:Electric | CORE_TOP VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 25546.82469 |
25 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.68861 |
26 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.22943 |
27 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.23400 |
28 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.16114 |
29 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.61182 |
30 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
31 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.66061E-003 |
32 | Coil:Heating:Electric | PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 5379.21150 |
33 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.61456 |
34 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.16275 |
35 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
36 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.12291 |
37 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.43401 |
38 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
39 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.34097E-003 |
40 | Coil:Heating:Electric | PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 4103.18811 |
41 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.67058 |
42 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.23560 |
43 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.24100 |
44 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.16161 |
45 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.62828 |
46 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
47 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.61712E-003 |
48 | Coil:Heating:Electric | PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 5395.04500 |
49 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.71465 |
50 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.13995 |
51 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
52 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.14293 |
53 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.37320 |
54 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
55 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.72241E-003 |
56 | Coil:Heating:Electric | PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 4771.46240 |
57 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.57754 |
58 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.27356 |
59 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.27900 |
60 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.16113 |
61 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.72949 |
62 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
63 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.39276E-003 |
64 | Coil:Heating:Electric | PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 5379.18164 |
65 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.55141 |
66 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.18139 |
67 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
68 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.11028 |
69 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.48371 |
70 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
71 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.10043E-003 |
72 | Coil:Heating:Electric | PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 3681.58633 |
73 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.56169 |
74 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.28128 |
75 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.28600 |
76 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.16064 |
77 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.75008 |
78 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
79 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.35453E-003 |
80 | Coil:Heating:Electric | PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 5362.78299 |
81 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.58871 |
82 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.16989 |
83 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
84 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.11774 |
85 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.45303 |
86 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
87 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.24266E-003 |
88 | Coil:Heating:Electric | PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 3930.62351 |
89 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.57696 |
90 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.27384 |
91 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.26400 |
92 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.15232 |
93 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.73023 |
94 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
95 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.39134E-003 |
96 | Coil:Heating:Electric | PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 5084.80227 |
97 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.58325 |
98 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.17149 |
99 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
100 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.11665 |
101 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.45731 |
102 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
103 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.22171E-003 |
104 | Coil:Heating:Electric | PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 3894.15421 |
105 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.56183 |
106 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.28121 |
107 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.27200 |
108 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.15282 |
109 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.74989 |
110 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
111 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.35486E-003 |
112 | Coil:Heating:Electric | PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 5101.51986 |
113 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.62883 |
114 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.15905 |
115 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
116 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.12577 |
117 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.42413 |
118 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
119 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.39549E-003 |
120 | Coil:Heating:Electric | PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 4198.47224 |
121 | AirLoopHVAC | PACU_VAV_BOT | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.49116 |
122 | AirLoopHVAC | PACU_VAV_BOT | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.31204 |
123 | AirLoopHVAC | PACU_VAV_BOT | Sum of Air Terminal Maximum Flow Rates [m3/s] | 4.98232 |
124 | AirLoopHVAC | PACU_VAV_BOT | Adjusted Heating Design Air Flow Rate [m3/s] | 1.31204 |
125 | AirLoopHVAC | PACU_VAV_BOT | Adjusted Cooling Design Air Flow Rate [m3/s] | 4.58443 |
126 | AirLoopHVAC | PACU_VAV_BOT | Adjusted Main Design Air Flow Rate [m3/s] | 4.58443 |
127 | AirLoopHVAC | PACU_VAV_BOT | User Heating Air Flow Ratio [] | 0.30000 |
128 | AirLoopHVAC | PACU_VAV_BOT | Calculated Heating Air Flow Ratio [] | 0.28619 |
129 | AirLoopHVAC | PACU_VAV_MID | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.14909 |
130 | AirLoopHVAC | PACU_VAV_MID | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.27195 |
131 | AirLoopHVAC | PACU_VAV_MID | Sum of Air Terminal Maximum Flow Rates [m3/s] | 4.29819 |
132 | AirLoopHVAC | PACU_VAV_MID | Adjusted Heating Design Air Flow Rate [m3/s] | 1.27195 |
133 | AirLoopHVAC | PACU_VAV_MID | Adjusted Cooling Design Air Flow Rate [m3/s] | 3.83852 |
134 | AirLoopHVAC | PACU_VAV_MID | Adjusted Main Design Air Flow Rate [m3/s] | 3.83852 |
135 | AirLoopHVAC | PACU_VAV_MID | User Heating Air Flow Ratio [] | 0.30000 |
136 | AirLoopHVAC | PACU_VAV_MID | Calculated Heating Air Flow Ratio [] | 0.33137 |
137 | AirLoopHVAC | PACU_VAV_TOP | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.41600 |
138 | AirLoopHVAC | PACU_VAV_TOP | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.35385 |
139 | AirLoopHVAC | PACU_VAV_TOP | Sum of Air Terminal Maximum Flow Rates [m3/s] | 4.83200 |
140 | AirLoopHVAC | PACU_VAV_TOP | Adjusted Heating Design Air Flow Rate [m3/s] | 1.35385 |
141 | AirLoopHVAC | PACU_VAV_TOP | Adjusted Cooling Design Air Flow Rate [m3/s] | 4.64025 |
142 | AirLoopHVAC | PACU_VAV_TOP | Adjusted Main Design Air Flow Rate [m3/s] | 4.64025 |
143 | AirLoopHVAC | PACU_VAV_TOP | User Heating Air Flow Ratio [] | 0.30000 |
144 | AirLoopHVAC | PACU_VAV_TOP | Calculated Heating Air Flow Ratio [] | 0.29176 |
145 | AirLoopHVAC | PACU_VAV_BOT | Design Supply Air Flow Rate [m3/s] | 4.58443 |
146 | AirLoopHVAC | PACU_VAV_MID | Design Supply Air Flow Rate [m3/s] | 3.83852 |
147 | AirLoopHVAC | PACU_VAV_TOP | Design Supply Air Flow Rate [m3/s] | 4.64025 |
148 | Controller:OutdoorAir | PACU_VAV_BOT_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 4.58443 |
149 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size High Speed Rated Air Flow Rate [m3/s] | 4.58443 |
150 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size High Speed Gross Rated Total Cooling Capacity [W] | 113842.41499 |
151 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size High Speed Rated Sensible Heat Ratio | 0.70108 |
152 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size Low Speed Rated Air Flow Rate [m3/s] | 1.52799 |
153 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size Low Speed Gross Rated Total Cooling Capacity [W] | 37943.67692 |
154 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size Low Speed Gross Rated Sensible Heat Ratio | 0.70108 |
155 | Coil:Heating:Fuel | PACU_VAV_BOT HEATING COIL | Design Size Nominal Capacity [W] | 21291.30452 |
156 | Fan:VariableVolume | PACU_VAV_BOT FAN | Design Size Maximum Flow Rate [m3/s] | 4.58443 |
157 | Controller:OutdoorAir | PACU_VAV_MID_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 3.83852 |
158 | HeatExchanger:AirToAir:SensibleAndLatent | PACU_VAV_MID OA HEAT RECOVERY | Design Size Nominal Supply Air Flow Rate [m3/s] | 1.19517 |
159 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size High Speed Rated Air Flow Rate [m3/s] | 3.83852 |
160 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size High Speed Gross Rated Total Cooling Capacity [W] | 95319.58471 |
161 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size High Speed Rated Sensible Heat Ratio | 0.70108 |
162 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size Low Speed Rated Air Flow Rate [m3/s] | 1.27938 |
163 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size Low Speed Gross Rated Total Cooling Capacity [W] | 31770.01758 |
164 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size Low Speed Gross Rated Sensible Heat Ratio | 0.70108 |
165 | Coil:Heating:Fuel | PACU_VAV_MID HEATING COIL | Design Size Nominal Capacity [W] | 17827.08409 |
166 | Fan:VariableVolume | PACU_VAV_MID FAN | Design Size Maximum Flow Rate [m3/s] | 3.83852 |
167 | Controller:OutdoorAir | PACU_VAV_TOP_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 4.64025 |
168 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size High Speed Rated Air Flow Rate [m3/s] | 4.64025 |
169 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size High Speed Gross Rated Total Cooling Capacity [W] | 115228.52510 |
170 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size High Speed Rated Sensible Heat Ratio | 0.70108 |
171 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size Low Speed Rated Air Flow Rate [m3/s] | 1.54660 |
172 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size Low Speed Gross Rated Total Cooling Capacity [W] | 38405.66742 |
173 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size Low Speed Gross Rated Sensible Heat Ratio | 0.70108 |
174 | Coil:Heating:Fuel | PACU_VAV_TOP HEATING COIL | Design Size Nominal Capacity [W] | 21550.54087 |
175 | Fan:VariableVolume | PACU_VAV_TOP FAN | Design Size Maximum Flow Rate [m3/s] | 4.64025 |
176 | PlantLoop | SWHSYS1 | Maximum Loop Flow Rate [m3/s] | 5.36267E-005 |
177 | PlantLoop | SWHSYS1 | Plant Loop Volume [m3] | 6.43520E-003 |
178 | Pump:ConstantSpeed | SWHSYS1 PUMP | Design Flow Rate [m3/s] | 5.36267E-005 |
179 | Pump:ConstantSpeed | SWHSYS1 PUMP | Design Power Consumption [W] | 0.72612 |
180 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | Use Side Design Flow Rate [m3/s] | 5.36267E-005 |
DX Coil Type | DX Coil Name | Fan Type | Fan Name | Standard Net Cooling Capacity {W} | Standard Net Cooling Capacity {Btu/h} | IEER {Btu/W-h} | COP 100% Capacity {W/W} | COP 75% Capacity {W/W} | COP 50% Capacity {W/W} | COP 25% Capacity {W/W} | EER 100% Capacity {Btu/W-h} | EER 75% Capacity {Btu/W-h} | EER 50% Capacity {Btu/W-h} | EER 25% Capacity {Btu/W-h} | Supply Air Flow 100% {kg/s} | Supply Air Flow 75% {kg/s} | Supply Air Flow 50% {kg/s} | Supply Air Flow 25% {kg/s} | |
1 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | N/A | N/A | 113656.48 | 387812.01 | 11.65 | 2.97 | 3.34 | 3.52 | 3.64 | 10.14 | 11.39 | 12.03 | 12.43 | 5.2999 | 4.1955 | 2.8233 | 1.2170 |
2 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | N/A | N/A | 95163.90 | 324712.72 | 11.65 | 2.97 | 3.34 | 3.52 | 3.64 | 10.14 | 11.39 | 12.03 | 12.43 | 4.4376 | 3.5128 | 2.3640 | 1.0190 |
3 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | N/A | N/A | 115040.33 | 392533.89 | 11.65 | 2.97 | 3.34 | 3.52 | 3.64 | 10.14 | 11.39 | 12.03 | 12.43 | 5.3644 | 4.2465 | 2.8577 | 1.2318 |
Zone Name | # Surfaces | |
1 | CORE_BOTTOM | 7 |
2 | TOPFLOOR_PLENUM | 10 |
3 | MIDFLOOR_PLENUM | 14 |
4 | FIRSTFLOOR_PLENUM | 14 |
5 | CORE_MID | 7 |
6 | CORE_TOP | 7 |
7 | PERIMETER_TOP_ZN_3 | 8 |
8 | PERIMETER_TOP_ZN_2 | 8 |
9 | PERIMETER_TOP_ZN_1 | 8 |
10 | PERIMETER_TOP_ZN_4 | 8 |
11 | PERIMETER_BOT_ZN_3 | 12 |
12 | PERIMETER_BOT_ZN_2 | 10 |
13 | PERIMETER_BOT_ZN_1 | 12 |
14 | PERIMETER_BOT_ZN_4 | 10 |
15 | PERIMETER_MID_ZN_3 | 8 |
16 | PERIMETER_MID_ZN_2 | 8 |
17 | PERIMETER_MID_ZN_1 | 8 |
18 | PERIMETER_MID_ZN_4 | 8 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | CORE_BOT_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_BOT_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | CORE_BOT_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_BOT_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
3 | CORE_BOT_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_BOT_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
4 | CORE_BOT_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_BOT_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
5 | CORE_BOT_ZN_5_FLOOR | Floor | CTF - ConductionTransferFunction | CORE_BOT_ZN_5_FLOOR_FFACTOR | 5.650E-003 | 5.642E-003 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | CORE_BOT_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
6 | CORE_BOT_ZN_5_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 983.54 | 983.54 | 983.54 | 180.00 | 0.00 | 40.76 | 24.13 | 0.00 | iz-CORE_BOT_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
7 | CORE_BOTTOM_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 1967.08 | 1967.08 | 1967.08 | 0.00 | 90.00 | 1967.08 | 1.00 | 0.00 | CORE_BOTTOM_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
8 | PERIMETER_TOP_PLENUM_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.375 | 1.140 | 60.85 | 60.85 | 60.85 | 0.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
9 | PERIMETER_TOP_PLENUM_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.375 | 1.140 | 40.57 | 40.57 | 40.57 | 90.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
10 | PERIMETER_TOP_PLENUM_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.375 | 1.140 | 60.85 | 60.85 | 60.85 | 180.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
11 | PERIMETER_TOP_PLENUM_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.375 | 1.140 | 40.57 | 40.57 | 40.57 | 270.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
12 | iz-PERIMETER_TOP_ZN_1_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 225.00 | 180.00 | 6.47 | 40.76 | 0.00 | PERIMETER_TOP_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
13 | iz-PERIMETER_TOP_ZN_2_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.26 | 131.26 | 131.26 | 135.00 | 180.00 | 6.47 | 24.13 | 0.00 | PERIMETER_TOP_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
14 | iz-PERIMETER_TOP_ZN_3_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 45.00 | 180.00 | 6.47 | 40.76 | 0.00 | PERIMETER_TOP_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
15 | iz-PERIMETER_TOP_ZN_4_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.25 | 131.25 | 131.25 | 315.00 | 180.00 | 6.47 | 24.13 | 0.00 | PERIMETER_TOP_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
16 | iz-CORE_TOP_ZN_5_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 983.54 | 983.54 | 983.54 | 180.00 | 180.00 | 40.76 | 24.13 | 0.00 | CORE_TOP_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
17 | BUILDING_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 1660.73 | 1660.73 | 1660.73 | 0.00 | 0.00 | 49.91 | 33.27 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
18 | PERIMETER_MID_PLENUM_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.013 | 0.880 | 60.85 | 60.85 | 60.85 | 0.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
19 | PERIMETER_MID_PLENUM_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.013 | 0.880 | 40.57 | 40.57 | 40.57 | 90.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
20 | PERIMETER_MID_PLENUM_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.013 | 0.880 | 60.85 | 60.85 | 60.85 | 180.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
21 | PERIMETER_MID_PLENUM_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.013 | 0.880 | 40.57 | 40.57 | 40.57 | 270.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
22 | iz-PERIMETER_MID_ZN_1_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | PERIMETER_MID_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
23 | iz-PERIMETER_MID_ZN_2_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | PERIMETER_MID_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
24 | iz-PERIMETER_MID_ZN_3_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | PERIMETER_MID_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
25 | iz-PERIMETER_MID_ZN_4_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | PERIMETER_MID_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
26 | iz-CORE_MID_ZN_5_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | CORE_MID_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
27 | iz-PERIMETER_TOP_ZN_1_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 207.34 | 207.34 | 207.34 | 0.00 | 0.00 | 40.76 | 6.47 | 0.00 | PERIMETER_TOP_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
28 | iz-PERIMETER_TOP_ZN_2_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 131.26 | 131.26 | 131.26 | 270.00 | 0.00 | 24.13 | 6.47 | 0.00 | PERIMETER_TOP_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
29 | iz-PERIMETER_TOP_ZN_3_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 207.34 | 207.34 | 207.34 | 180.00 | 0.00 | 40.76 | 6.47 | 0.00 | PERIMETER_TOP_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
30 | iz-PERIMETER_TOP_ZN_4_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 131.25 | 131.25 | 131.25 | 90.00 | 0.00 | 24.13 | 6.47 | 0.00 | PERIMETER_TOP_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
31 | iz-CORE_TOP_ZN_5_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 983.54 | 983.54 | 983.54 | 180.00 | 0.00 | 40.76 | 24.13 | 0.00 | CORE_TOP_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
32 | PERIMETER_BOT_PLENUM_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.029 | 0.892 | 60.85 | 60.85 | 60.85 | 0.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
33 | PERIMETER_BOT_PLENUM_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.029 | 0.892 | 40.57 | 40.57 | 40.57 | 90.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
34 | PERIMETER_BOT_PLENUM_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.029 | 0.892 | 60.85 | 60.85 | 60.85 | 180.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
35 | PERIMETER_BOT_PLENUM_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.029 | 0.892 | 40.57 | 40.57 | 40.57 | 270.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
36 | iz-PERIMETER_BOT_ZN_1_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | PERIMETER_BOT_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
37 | iz-PERIMETER_BOT_ZN_2_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | PERIMETER_BOT_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
38 | iz-PERIMETER_BOT_ZN_3_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | PERIMETER_BOT_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
39 | iz-PERIMETER_BOT_ZN_4_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | PERIMETER_BOT_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
40 | iz-CORE_BOT_ZN_5_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | CORE_BOT_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
41 | iz-PERIMETER_MID_ZN_1_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 207.34 | 207.34 | 207.34 | 0.00 | 0.00 | 40.76 | 6.47 | 0.00 | PERIMETER_MID_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
42 | iz-PERIMETER_MID_ZN_2_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 131.26 | 131.26 | 131.26 | 270.00 | 0.00 | 24.13 | 6.47 | 0.00 | PERIMETER_MID_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
43 | iz-PERIMETER_MID_ZN_3_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 207.34 | 207.34 | 207.34 | 180.00 | 0.00 | 40.76 | 6.47 | 0.00 | PERIMETER_MID_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
44 | iz-PERIMETER_MID_ZN_4_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 131.25 | 131.25 | 131.25 | 90.00 | 0.00 | 24.13 | 6.47 | 0.00 | PERIMETER_MID_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
45 | iz-CORE_MID_ZN_5_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 983.54 | 983.54 | 983.54 | 180.00 | 0.00 | 40.76 | 24.13 | 0.00 | CORE_MID_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
46 | CORE_MID_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_MID_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
47 | CORE_MID_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_MID_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
48 | CORE_MID_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_MID_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
49 | CORE_MID_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_MID_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
50 | CORE_MID_ZN_5_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | iz-CORE_MID_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
51 | CORE_MID_ZN_5_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 983.54 | 983.54 | 983.54 | 180.00 | 0.00 | 40.76 | 24.13 | 0.00 | iz-CORE_MID_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
52 | CORE_MID_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 1967.08 | 1967.08 | 1967.08 | 0.00 | 90.00 | 1967.08 | 1.00 | 0.00 | CORE_MID_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
53 | CORE_TOP_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_TOP_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
54 | CORE_TOP_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_TOP_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
55 | CORE_TOP_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_TOP_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
56 | CORE_TOP_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_TOP_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
57 | CORE_TOP_ZN_5_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | iz-CORE_TOP_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
58 | CORE_TOP_ZN_5_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 983.54 | 983.54 | 983.54 | 0.00 | 0.00 | 40.76 | 24.13 | 0.00 | iz-CORE_TOP_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
59 | CORE_TOP_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 1967.08 | 1967.08 | 1967.08 | 0.00 | 90.00 | 1967.08 | 1.00 | 0.00 | CORE_TOP_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
60 | PERIMETER_TOP_ZN_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.375 | 1.140 | 77.59 | 136.92 | 77.59 | 0.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | Window | PERIMETER_TOP_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.5037_SHGC_NORTH_0.23 | N/A | 2.864 | No | 59.33 | 59.33 | 59.33 | 0.00 | 90.00 | 49.91 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
62 | PERIMETER_TOP_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_TOP_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
63 | iz-PERIMETER_TOP_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
64 | iz-CORE_TOP_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
65 | PERIMETER_TOP_ZN_3_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_TOP_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
66 | PERIMETER_TOP_ZN_3_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 225.00 | 0.00 | 6.47 | 49.91 | 0.00 | iz-PERIMETER_TOP_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
67 | PERIMETER_TOP_ZN_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.68 | 414.68 | 414.68 | 0.00 | 90.00 | 414.68 | 1.00 | 0.00 | PERIMETER_TOP_ZN_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
68 | PERIMETER_TOP_ZN_2_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.375 | 1.140 | 51.72 | 91.28 | 51.72 | 90.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
69 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | Window | PERIMETER_TOP_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.5037_SHGC_EAST_0.23 | N/A | 2.864 | No | 39.55 | 39.55 | 39.55 | 90.00 | 90.00 | 33.27 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
70 | PERIMETER_TOP_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_TOP_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
71 | iz-PERIMETER_TOP_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
72 | iz-CORE_TOP_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
73 | PERIMETER_TOP_ZN_2_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_TOP_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
74 | PERIMETER_TOP_ZN_2_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.26 | 131.26 | 131.26 | 315.00 | 0.00 | 6.47 | 33.27 | 0.00 | iz-PERIMETER_TOP_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
75 | PERIMETER_TOP_ZN_2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_TOP_ZN_2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
76 | PERIMETER_TOP_ZN_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.375 | 1.140 | 77.59 | 136.92 | 77.59 | 180.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
77 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | Window | PERIMETER_TOP_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.5037_SHGC_SOUTH_0.23 | N/A | 2.864 | No | 59.33 | 59.33 | 59.33 | 180.00 | 90.00 | 49.91 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
78 | PERIMETER_TOP_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_TOP_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
79 | iz-PERIMETER_TOP_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
80 | iz-CORE_TOP_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
81 | PERIMETER_TOP_ZN_1_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_TOP_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
82 | PERIMETER_TOP_ZN_1_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 45.00 | 0.00 | 6.47 | 49.91 | 0.00 | iz-PERIMETER_TOP_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
83 | PERIMETER_TOP_ZN_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.67 | 414.67 | 414.67 | 0.00 | 90.00 | 414.67 | 1.00 | 0.00 | PERIMETER_TOP_ZN_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
84 | PERIMETER_TOP_ZN_4_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.375 | 1.140 | 51.72 | 91.28 | 51.72 | 270.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
85 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | Window | PERIMETER_TOP_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.5037_SHGC_WEST_0.23 | N/A | 2.864 | No | 39.55 | 39.55 | 39.55 | 270.00 | 90.00 | 33.27 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
86 | PERIMETER_TOP_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_TOP_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
87 | iz-PERIMETER_TOP_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
88 | iz-CORE_TOP_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
89 | PERIMETER_TOP_ZN_4_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_TOP_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
90 | PERIMETER_TOP_ZN_4_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.25 | 131.25 | 131.25 | 135.00 | 0.00 | 6.47 | 33.27 | 0.00 | iz-PERIMETER_TOP_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
91 | PERIMETER_TOP_ZN_4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_TOP_ZN_4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
92 | PERIMETER_BOT_ZN_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.029 | 0.892 | 73.69 | 136.92 | 73.69 | 0.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
93 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | Window | PERIMETER_BOT_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.5037_SHGC_NORTH_0.23 | N/A | 2.864 | No | 19.78 | 19.78 | 19.78 | 0.00 | 90.00 | 15.82 | 1.25 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
94 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | Window | PERIMETER_BOT_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.5037_SHGC_NORTH_0.23 | N/A | 2.864 | No | 19.78 | 19.78 | 19.78 | 0.00 | 90.00 | 15.82 | 1.25 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
95 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | Window | PERIMETER_BOT_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.5037_SHGC_NORTH_0.23 | N/A | 2.864 | No | 19.78 | 19.78 | 19.78 | 0.00 | 90.00 | 15.82 | 1.25 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
96 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | Door | PERIMETER_BOT_ZN_3_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
97 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | Door | PERIMETER_BOT_ZN_3_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
98 | PERIMETER_BOT_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_BOT_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
99 | iz-PERIMETER_BOT_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
100 | iz-CORE_BOT_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
101 | PERIMETER_BOT_ZN_3_FLOOR | Floor | CTF - ConductionTransferFunction | PERIMETER_BOT_ZN_3_FLOOR_FFACTOR | 0.319 | 0.296 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
102 | PERIMETER_BOT_ZN_3_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 180.00 | 0.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_BOT_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
103 | PERIMETER_BOT_ZN_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.68 | 414.68 | 414.68 | 0.00 | 90.00 | 414.68 | 1.00 | 0.00 | PERIMETER_BOT_ZN_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
104 | PERIMETER_BOT_ZN_2_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.029 | 0.892 | 49.77 | 91.28 | 49.77 | 90.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
105 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | Window | PERIMETER_BOT_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.5037_SHGC_EAST_0.23 | N/A | 2.864 | No | 38.05 | 38.05 | 38.05 | 90.00 | 90.00 | 30.84 | 1.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
106 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | Window | PERIMETER_BOT_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.5037_SHGC_EAST_0.23 | N/A | 2.864 | No | 1.50 | 1.50 | 1.50 | 90.00 | 90.00 | 1.22 | 1.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
107 | PERIMETER_BOT_ZN_2_WALL_EAST_DOOR | Door | PERIMETER_BOT_ZN_2_WALL_EAST | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
108 | PERIMETER_BOT_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_BOT_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
109 | iz-PERIMETER_BOT_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
110 | iz-CORE_BOT_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
111 | PERIMETER_BOT_ZN_2_FLOOR | Floor | CTF - ConductionTransferFunction | PERIMETER_BOT_ZN_2_FLOOR_FFACTOR | 0.337 | 0.312 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
112 | PERIMETER_BOT_ZN_2_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.26 | 131.26 | 131.26 | 270.00 | 0.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_BOT_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
113 | PERIMETER_BOT_ZN_2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_BOT_ZN_2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
114 | PERIMETER_BOT_ZN_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.029 | 0.892 | 73.69 | 136.92 | 73.69 | 180.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
115 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | Window | PERIMETER_BOT_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.5037_SHGC_SOUTH_0.23 | N/A | 2.864 | No | 19.78 | 19.78 | 19.78 | 180.00 | 90.00 | 15.82 | 1.25 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
116 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | Window | PERIMETER_BOT_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.5037_SHGC_SOUTH_0.23 | N/A | 2.864 | No | 19.78 | 19.78 | 19.78 | 180.00 | 90.00 | 15.82 | 1.25 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
117 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | Window | PERIMETER_BOT_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.5037_SHGC_SOUTH_0.23 | N/A | 2.864 | No | 19.78 | 19.78 | 19.78 | 180.00 | 90.00 | 15.82 | 1.25 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
118 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | Door | PERIMETER_BOT_ZN_1_WALL_SOUTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 180.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
119 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | Door | PERIMETER_BOT_ZN_1_WALL_SOUTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 180.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
120 | PERIMETER_BOT_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_BOT_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
121 | iz-PERIMETER_BOT_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
122 | iz-CORE_BOT_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
123 | PERIMETER_BOT_ZN_1_FLOOR | Floor | CTF - ConductionTransferFunction | PERIMETER_BOT_ZN_1_FLOOR_FFACTOR | 0.319 | 0.296 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
124 | PERIMETER_BOT_ZN_1_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 0.00 | 0.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_BOT_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
125 | PERIMETER_BOT_ZN_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.67 | 414.67 | 414.67 | 0.00 | 90.00 | 414.67 | 1.00 | 0.00 | PERIMETER_BOT_ZN_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
126 | PERIMETER_BOT_ZN_4_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.029 | 0.892 | 49.77 | 91.28 | 49.77 | 270.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
127 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | Window | PERIMETER_BOT_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.5037_SHGC_WEST_0.23 | N/A | 2.864 | No | 38.05 | 38.05 | 38.05 | 270.00 | 90.00 | 30.84 | 1.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
128 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | Window | PERIMETER_BOT_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.5037_SHGC_WEST_0.23 | N/A | 2.864 | No | 1.50 | 1.50 | 1.50 | 270.00 | 90.00 | 1.22 | 1.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
129 | PERIMETER_BOT_ZN_4_WALL_WEST_DOOR | Door | PERIMETER_BOT_ZN_4_WALL_WEST | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
130 | PERIMETER_BOT_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_BOT_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
131 | iz-PERIMETER_BOT_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
132 | iz-CORE_BOT_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
133 | PERIMETER_BOT_ZN_4_FLOOR | Floor | CTF - ConductionTransferFunction | PERIMETER_BOT_ZN_4_FLOOR_FFACTOR | 0.337 | 0.312 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
134 | PERIMETER_BOT_ZN_4_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.25 | 131.25 | 131.25 | 90.00 | 0.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_BOT_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
135 | PERIMETER_BOT_ZN_4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_BOT_ZN_4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
136 | PERIMETER_MID_ZN_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.013 | 0.880 | 77.59 | 136.92 | 77.59 | 0.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
137 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | Window | PERIMETER_MID_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.5037_SHGC_NORTH_0.23 | N/A | 2.864 | No | 59.33 | 59.33 | 59.33 | 0.00 | 90.00 | 49.91 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
138 | PERIMETER_MID_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_MID_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
139 | iz-PERIMETER_MID_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
140 | iz-CORE_MID_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
141 | PERIMETER_MID_ZN_3_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
142 | PERIMETER_MID_ZN_3_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 180.00 | 0.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
143 | PERIMETER_MID_ZN_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.68 | 414.68 | 414.68 | 0.00 | 90.00 | 414.68 | 1.00 | 0.00 | PERIMETER_MID_ZN_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
144 | PERIMETER_MID_ZN_2_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.013 | 0.880 | 51.72 | 91.28 | 51.72 | 90.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
145 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | Window | PERIMETER_MID_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.5037_SHGC_EAST_0.23 | N/A | 2.864 | No | 39.55 | 39.55 | 39.55 | 90.00 | 90.00 | 33.27 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
146 | PERIMETER_MID_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_MID_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
147 | iz-PERIMETER_MID_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
148 | iz-CORE_MID_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
149 | PERIMETER_MID_ZN_2_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
150 | PERIMETER_MID_ZN_2_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.26 | 131.26 | 131.26 | 270.00 | 0.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
151 | PERIMETER_MID_ZN_2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_MID_ZN_2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
152 | PERIMETER_MID_ZN_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.013 | 0.880 | 77.59 | 136.92 | 77.59 | 180.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
153 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | Window | PERIMETER_MID_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.5037_SHGC_SOUTH_0.23 | N/A | 2.864 | No | 59.33 | 59.33 | 59.33 | 180.00 | 90.00 | 49.91 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
154 | PERIMETER_MID_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_MID_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
155 | iz-PERIMETER_MID_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
156 | iz-CORE_MID_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
157 | PERIMETER_MID_ZN_1_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
158 | PERIMETER_MID_ZN_1_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 0.00 | 0.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
159 | PERIMETER_MID_ZN_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.67 | 414.67 | 414.67 | 0.00 | 90.00 | 414.67 | 1.00 | 0.00 | PERIMETER_MID_ZN_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
160 | PERIMETER_MID_ZN_4_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.013 | 0.880 | 51.72 | 91.28 | 51.72 | 270.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
161 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | Window | PERIMETER_MID_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.5037_SHGC_WEST_0.23 | N/A | 2.864 | No | 39.55 | 39.55 | 39.55 | 270.00 | 90.00 | 33.27 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
162 | PERIMETER_MID_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_MID_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
163 | iz-PERIMETER_MID_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
164 | iz-CORE_MID_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
165 | PERIMETER_MID_ZN_4_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
166 | PERIMETER_MID_ZN_4_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.25 | 131.25 | 131.25 | 90.00 | 0.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
167 | PERIMETER_MID_ZN_4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_MID_ZN_4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes | Clark and Allen |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1Environment:Special Days |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | CORE_BOTTOM | RunPeriod: RUNPERIOD 1 | 0.3986650241 | 0.3185261993 | Pass | Pass | 0.1736959763 | 0.3809246566 | Pass | Fail |
2 | TOPFLOOR_PLENUM | RunPeriod: RUNPERIOD 1 | 6.5817400150E-002 | 8.4857728756E-002 | Pass | Pass | 0.1847192742 | 0.4085955306 | Pass | Pass |
3 | MIDFLOOR_PLENUM | RunPeriod: RUNPERIOD 1 | 3.9633748054E-002 | 5.4323220061E-002 | Pass | Pass | 0.2402326527 | 0.7449469031 | Fail | Fail |
4 | FIRSTFLOOR_PLENUM | RunPeriod: RUNPERIOD 1 | 6.7556438652E-002 | 5.7017641647E-002 | Pass | Pass | 0.2561462341 | 0.9646353611 | Fail | Fail |
5 | CORE_MID | RunPeriod: RUNPERIOD 1 | 0.2156284085 | 0.2604078007 | Pass | Pass | 0.1625719940 | 0.3672084467 | Pass | Fail |
6 | CORE_TOP | RunPeriod: RUNPERIOD 1 | 0.2223786988 | 0.2802344626 | Pass | Pass | 0.1695144330 | 0.3743311712 | Pass | Pass |
7 | PERIMETER_TOP_ZN_3 | RunPeriod: RUNPERIOD 1 | 0.2235765077 | 0.2834391330 | Pass | Pass | 0.1743257791 | 0.3791351694 | Pass | Fail |
8 | PERIMETER_TOP_ZN_2 | RunPeriod: RUNPERIOD 1 | 0.2606396283 | 0.3376756982 | Pass | Pass | 0.1868751828 | 0.4003594586 | Pass | Fail |
9 | PERIMETER_TOP_ZN_1 | RunPeriod: RUNPERIOD 1 | 0.2308952135 | 0.3094063190 | Pass | Pass | 0.2074804622 | 0.4534982085 | Pass | Fail |
10 | PERIMETER_TOP_ZN_4 | RunPeriod: RUNPERIOD 1 | 0.2883919509 | 0.3743212213 | Pass | Pass | 0.1706703475 | 0.3741786727 | Pass | Pass |
11 | PERIMETER_BOT_ZN_3 | RunPeriod: RUNPERIOD 1 | 0.3500842836 | 0.2951335689 | Pass | Pass | 0.1678359217 | 0.3732137827 | Pass | Fail |
12 | PERIMETER_BOT_ZN_2 | RunPeriod: RUNPERIOD 1 | 0.3727259374 | 0.3227236455 | Pass | Pass | 0.1753445728 | 0.3867440075 | Pass | Fail |
13 | PERIMETER_BOT_ZN_1 | RunPeriod: RUNPERIOD 1 | 0.3553755159 | 0.3154645871 | Pass | Pass | 0.1877367493 | 0.4198762442 | Pass | Fail |
14 | PERIMETER_BOT_ZN_4 | RunPeriod: RUNPERIOD 1 | 0.3886321377 | 0.3335610314 | Pass | Pass | 0.1684709445 | 0.3746224966 | Pass | Fail |
15 | PERIMETER_MID_ZN_3 | RunPeriod: RUNPERIOD 1 | 0.2053732453 | 0.2605114898 | Pass | Pass | 0.1634878288 | 0.3679904791 | Pass | Fail |
16 | PERIMETER_MID_ZN_2 | RunPeriod: RUNPERIOD 1 | 0.2403301624 | 0.3119265735 | Pass | Pass | 0.1732890090 | 0.3847044646 | Pass | Pass |
17 | PERIMETER_MID_ZN_1 | RunPeriod: RUNPERIOD 1 | 0.2072748680 | 0.2777193785 | Pass | Pass | 0.1806578510 | 0.4080324184 | Pass | Fail |
18 | PERIMETER_MID_ZN_4 | RunPeriod: RUNPERIOD 1 | 0.2517335350 | 0.3263317300 | Pass | Pass | 0.1626447251 | 0.3664536032 | Pass | Fail |
Report: Annual Heat Emissions Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
Heat Emission by ComponentsEnvelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
Heat Emissions [GJ] | 3226.33 | -107.4 | 0.00 | -2202.1 | 4278.92 | 5195.73 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 20.10 | 0.00 | 20.10 | Wetbulb [C] | 1.80 | 0.00 |
HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 35.20 | 8.50 | 25.80 | Wetbulb [C] | 4.10 | 160.00 |
Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
Jan | 57.00 | 12 | |||
Feb | 0.00 | 0 | |||
Mar | 153.60 | 31 | |||
Apr | 87.00 | 59 | |||
May | 227.22 | 128 | |||
Jun | 144.58 | 109 | |||
Jul | 42.40 | 24 | |||
Aug | 164.90 | 163 | |||
Sep | 119.60 | 50 | |||
Oct | 365.70 | 188 | |||
Nov | 70.90 | 67 | |||
Dec | 0.00 | 0 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
PERIMETER_TOP_PLENUM_WALL_NORTH | NONRES_EXT_WALL_TOP | 0.30 | 1.140 | 1.375 | 60.85 | 60.85 | 0.00 | 90.00 | N |
PERIMETER_TOP_PLENUM_WALL_EAST | NONRES_EXT_WALL_TOP | 0.30 | 1.140 | 1.375 | 40.57 | 40.57 | 90.00 | 90.00 | E |
PERIMETER_TOP_PLENUM_WALL_SOUTH | NONRES_EXT_WALL_TOP | 0.30 | 1.140 | 1.375 | 60.85 | 60.85 | 180.00 | 90.00 | S |
PERIMETER_TOP_PLENUM_WALL_WEST | NONRES_EXT_WALL_TOP | 0.30 | 1.140 | 1.375 | 40.57 | 40.57 | 270.00 | 90.00 | W |
BUILDING_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 1660.73 | 1660.73 | 0.00 | 0.00 | |
PERIMETER_MID_PLENUM_WALL_NORTH | NONRES_EXT_WALL_MID | 0.30 | 0.880 | 1.013 | 60.85 | 60.85 | 0.00 | 90.00 | N |
PERIMETER_MID_PLENUM_WALL_EAST | NONRES_EXT_WALL_MID | 0.30 | 0.880 | 1.013 | 40.57 | 40.57 | 90.00 | 90.00 | E |
PERIMETER_MID_PLENUM_WALL_SOUTH | NONRES_EXT_WALL_MID | 0.30 | 0.880 | 1.013 | 60.85 | 60.85 | 180.00 | 90.00 | S |
PERIMETER_MID_PLENUM_WALL_WEST | NONRES_EXT_WALL_MID | 0.30 | 0.880 | 1.013 | 40.57 | 40.57 | 270.00 | 90.00 | W |
PERIMETER_BOT_PLENUM_WALL_NORTH | NONRES_EXT_WALL_GRD | 0.30 | 0.892 | 1.029 | 60.85 | 60.85 | 0.00 | 90.00 | N |
PERIMETER_BOT_PLENUM_WALL_EAST | NONRES_EXT_WALL_GRD | 0.30 | 0.892 | 1.029 | 40.57 | 40.57 | 90.00 | 90.00 | E |
PERIMETER_BOT_PLENUM_WALL_SOUTH | NONRES_EXT_WALL_GRD | 0.30 | 0.892 | 1.029 | 60.85 | 60.85 | 180.00 | 90.00 | S |
PERIMETER_BOT_PLENUM_WALL_WEST | NONRES_EXT_WALL_GRD | 0.30 | 0.892 | 1.029 | 40.57 | 40.57 | 270.00 | 90.00 | W |
PERIMETER_TOP_ZN_3_WALL_NORTH | NONRES_EXT_WALL_TOP | 0.30 | 1.140 | 1.375 | 136.92 | 77.59 | 0.00 | 90.00 | N |
PERIMETER_TOP_ZN_2_WALL_EAST | NONRES_EXT_WALL_TOP | 0.30 | 1.140 | 1.375 | 91.28 | 51.72 | 90.00 | 90.00 | E |
PERIMETER_TOP_ZN_1_WALL_SOUTH | NONRES_EXT_WALL_TOP | 0.30 | 1.140 | 1.375 | 136.92 | 77.59 | 180.00 | 90.00 | S |
PERIMETER_TOP_ZN_4_WALL_WEST | NONRES_EXT_WALL_TOP | 0.30 | 1.140 | 1.375 | 91.28 | 51.72 | 270.00 | 90.00 | W |
PERIMETER_BOT_ZN_3_WALL_NORTH | NONRES_EXT_WALL_GRD | 0.30 | 0.892 | 1.029 | 136.92 | 73.69 | 0.00 | 90.00 | N |
PERIMETER_BOT_ZN_3_FLOOR | PERIMETER_BOT_ZN_3_FLOOR_FFACTOR | 1.00 | 0.304 | 0.319 | 207.34 | 207.34 | 0.00 | 180.00 | |
PERIMETER_BOT_ZN_2_WALL_EAST | NONRES_EXT_WALL_GRD | 0.30 | 0.892 | 1.029 | 91.28 | 49.77 | 90.00 | 90.00 | E |
PERIMETER_BOT_ZN_2_FLOOR | PERIMETER_BOT_ZN_2_FLOOR_FFACTOR | 1.00 | 0.320 | 0.337 | 131.26 | 131.26 | 90.00 | 180.00 | |
PERIMETER_BOT_ZN_1_WALL_SOUTH | NONRES_EXT_WALL_GRD | 0.30 | 0.892 | 1.029 | 136.92 | 73.69 | 180.00 | 90.00 | S |
PERIMETER_BOT_ZN_1_FLOOR | PERIMETER_BOT_ZN_1_FLOOR_FFACTOR | 1.00 | 0.304 | 0.319 | 207.34 | 207.34 | 180.00 | 180.00 | |
PERIMETER_BOT_ZN_4_WALL_WEST | NONRES_EXT_WALL_GRD | 0.30 | 0.892 | 1.029 | 91.28 | 49.77 | 270.00 | 90.00 | W |
PERIMETER_BOT_ZN_4_FLOOR | PERIMETER_BOT_ZN_4_FLOOR_FFACTOR | 1.00 | 0.320 | 0.337 | 131.25 | 131.25 | 270.00 | 180.00 | |
PERIMETER_MID_ZN_3_WALL_NORTH | NONRES_EXT_WALL_MID | 0.30 | 0.880 | 1.013 | 136.92 | 77.59 | 0.00 | 90.00 | N |
PERIMETER_MID_ZN_2_WALL_EAST | NONRES_EXT_WALL_MID | 0.30 | 0.880 | 1.013 | 91.28 | 51.72 | 90.00 | 90.00 | E |
PERIMETER_MID_ZN_1_WALL_SOUTH | NONRES_EXT_WALL_MID | 0.30 | 0.880 | 1.013 | 136.92 | 77.59 | 180.00 | 90.00 | S |
PERIMETER_MID_ZN_4_WALL_WEST | NONRES_EXT_WALL_MID | 0.30 | 0.880 | 1.013 | 91.28 | 51.72 | 270.00 | 90.00 | W |
Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
CORE_BOT_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
CORE_BOT_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
CORE_BOT_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
CORE_BOT_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
CORE_BOT_ZN_5_FLOOR | CORE_BOT_ZN_5_FLOOR_FFACTOR | 1.00 | 0.006 | 0.006 | 983.54 | 983.54 | 0.00 | 180.00 | |
CORE_BOT_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 180.00 | 0.00 | |
iz-PERIMETER_TOP_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 225.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 135.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 45.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 315.00 | 180.00 | |
iz-CORE_TOP_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 180.00 | 180.00 | |
iz-PERIMETER_MID_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 180.00 | 180.00 | |
iz-PERIMETER_MID_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 90.00 | 180.00 | |
iz-PERIMETER_MID_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 0.00 | 180.00 | |
iz-PERIMETER_MID_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 270.00 | 180.00 | |
iz-CORE_MID_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 0.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_1_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 0.00 | 0.00 | |
iz-PERIMETER_TOP_ZN_2_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 131.26 | 131.26 | 270.00 | 0.00 | |
iz-PERIMETER_TOP_ZN_3_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 180.00 | 0.00 | |
iz-PERIMETER_TOP_ZN_4_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 131.25 | 131.25 | 90.00 | 0.00 | |
iz-CORE_TOP_ZN_5_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 983.54 | 983.54 | 180.00 | 0.00 | |
iz-PERIMETER_BOT_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 180.00 | 180.00 | |
iz-PERIMETER_BOT_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 90.00 | 180.00 | |
iz-PERIMETER_BOT_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 0.00 | 180.00 | |
iz-PERIMETER_BOT_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 270.00 | 180.00 | |
iz-CORE_BOT_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 0.00 | 180.00 | |
iz-PERIMETER_MID_ZN_1_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 0.00 | 0.00 | |
iz-PERIMETER_MID_ZN_2_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 131.26 | 131.26 | 270.00 | 0.00 | |
iz-PERIMETER_MID_ZN_3_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 180.00 | 0.00 | |
iz-PERIMETER_MID_ZN_4_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 131.25 | 131.25 | 90.00 | 0.00 | |
iz-CORE_MID_ZN_5_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 983.54 | 983.54 | 180.00 | 0.00 | |
CORE_MID_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
CORE_MID_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
CORE_MID_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
CORE_MID_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
CORE_MID_ZN_5_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 983.54 | 983.54 | 0.00 | 180.00 | |
CORE_MID_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 180.00 | 0.00 | |
CORE_TOP_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
CORE_TOP_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
CORE_TOP_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
CORE_TOP_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
CORE_TOP_ZN_5_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 983.54 | 983.54 | 0.00 | 180.00 | |
CORE_TOP_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 0.00 | 0.00 | |
PERIMETER_TOP_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-PERIMETER_TOP_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-CORE_TOP_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
PERIMETER_TOP_ZN_3_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 0.00 | 180.00 | |
PERIMETER_TOP_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 225.00 | 0.00 | |
PERIMETER_TOP_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-PERIMETER_TOP_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-CORE_TOP_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
PERIMETER_TOP_ZN_2_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 131.26 | 131.26 | 90.00 | 180.00 | |
PERIMETER_TOP_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 315.00 | 0.00 | |
PERIMETER_TOP_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-PERIMETER_TOP_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-CORE_TOP_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
PERIMETER_TOP_ZN_1_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 180.00 | 180.00 | |
PERIMETER_TOP_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 45.00 | 0.00 | |
PERIMETER_TOP_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-PERIMETER_TOP_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-CORE_TOP_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
PERIMETER_TOP_ZN_4_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 131.25 | 131.25 | 270.00 | 180.00 | |
PERIMETER_TOP_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 135.00 | 0.00 | |
PERIMETER_BOT_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-PERIMETER_BOT_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-CORE_BOT_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
PERIMETER_BOT_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 180.00 | 0.00 | |
PERIMETER_BOT_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-PERIMETER_BOT_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-CORE_BOT_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
PERIMETER_BOT_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 270.00 | 0.00 | |
PERIMETER_BOT_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-PERIMETER_BOT_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-CORE_BOT_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
PERIMETER_BOT_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 0.00 | 0.00 | |
PERIMETER_BOT_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-PERIMETER_BOT_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-CORE_BOT_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
PERIMETER_BOT_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 90.00 | 0.00 | |
PERIMETER_MID_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-PERIMETER_MID_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-CORE_MID_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
PERIMETER_MID_ZN_3_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 0.00 | 180.00 | |
PERIMETER_MID_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 180.00 | 0.00 | |
PERIMETER_MID_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-PERIMETER_MID_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-CORE_MID_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
PERIMETER_MID_ZN_2_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 131.26 | 131.26 | 90.00 | 180.00 | |
PERIMETER_MID_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 270.00 | 0.00 | |
PERIMETER_MID_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-PERIMETER_MID_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-CORE_MID_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
PERIMETER_MID_ZN_1_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 180.00 | 180.00 | |
PERIMETER_MID_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 0.00 | 0.00 | |
PERIMETER_MID_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-PERIMETER_MID_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-CORE_MID_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
PERIMETER_MID_ZN_4_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 131.25 | 131.25 | 270.00 | 180.00 | |
PERIMETER_MID_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 90.00 | 0.00 | |
CORE_BOTTOM_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 1967.08 | 0.00 | 90.00 | N | ||
CORE_MID_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 1967.08 | 0.00 | 90.00 | N | ||
CORE_TOP_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 1967.08 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.68 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_2_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.67 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_4_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.68 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_2_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.67 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_4_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.68 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_2_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.67 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_4_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N |
Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | WINDOW_U_0.5037_SHGC_NORTH_0.23 | 59.33 | 0.00 | 0.00 | 59.33 | 59.33 | 2.864 | 0.231 | 0.231 | No | PERIMETER_TOP_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | WINDOW_U_0.5037_SHGC_EAST_0.23 | 39.55 | 0.00 | 0.00 | 39.55 | 39.55 | 2.864 | 0.231 | 0.231 | No | PERIMETER_TOP_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | WINDOW_U_0.5037_SHGC_SOUTH_0.23 | 59.33 | 0.00 | 0.00 | 59.33 | 59.33 | 2.864 | 0.231 | 0.231 | No | PERIMETER_TOP_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | WINDOW_U_0.5037_SHGC_WEST_0.23 | 39.55 | 0.00 | 0.00 | 39.55 | 39.55 | 2.864 | 0.231 | 0.231 | No | PERIMETER_TOP_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | WINDOW_U_0.5037_SHGC_NORTH_0.23 | 19.78 | 0.00 | 0.00 | 19.78 | 19.78 | 2.864 | 0.231 | 0.231 | No | PERIMETER_BOT_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | WINDOW_U_0.5037_SHGC_NORTH_0.23 | 19.78 | 0.00 | 0.00 | 19.78 | 19.78 | 2.864 | 0.231 | 0.231 | No | PERIMETER_BOT_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | WINDOW_U_0.5037_SHGC_NORTH_0.23 | 19.78 | 0.00 | 0.00 | 19.78 | 19.78 | 2.864 | 0.231 | 0.231 | No | PERIMETER_BOT_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | WINDOW_U_0.5037_SHGC_EAST_0.23 | 38.05 | 0.00 | 0.00 | 38.05 | 38.05 | 2.864 | 0.231 | 0.231 | No | PERIMETER_BOT_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | WINDOW_U_0.5037_SHGC_EAST_0.23 | 1.50 | 0.00 | 0.00 | 1.50 | 1.50 | 2.864 | 0.231 | 0.231 | No | PERIMETER_BOT_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | WINDOW_U_0.5037_SHGC_SOUTH_0.23 | 19.78 | 0.00 | 0.00 | 19.78 | 19.78 | 2.864 | 0.231 | 0.231 | No | PERIMETER_BOT_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | WINDOW_U_0.5037_SHGC_SOUTH_0.23 | 19.78 | 0.00 | 0.00 | 19.78 | 19.78 | 2.864 | 0.231 | 0.231 | No | PERIMETER_BOT_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | WINDOW_U_0.5037_SHGC_SOUTH_0.23 | 19.78 | 0.00 | 0.00 | 19.78 | 19.78 | 2.864 | 0.231 | 0.231 | No | PERIMETER_BOT_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | WINDOW_U_0.5037_SHGC_WEST_0.23 | 38.05 | 0.00 | 0.00 | 38.05 | 38.05 | 2.864 | 0.231 | 0.231 | No | PERIMETER_BOT_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | WINDOW_U_0.5037_SHGC_WEST_0.23 | 1.50 | 0.00 | 0.00 | 1.50 | 1.50 | 2.864 | 0.231 | 0.231 | No | PERIMETER_BOT_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | WINDOW_U_0.5037_SHGC_NORTH_0.23 | 59.33 | 0.00 | 0.00 | 59.33 | 59.33 | 2.864 | 0.231 | 0.231 | No | PERIMETER_MID_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | WINDOW_U_0.5037_SHGC_EAST_0.23 | 39.55 | 0.00 | 0.00 | 39.55 | 39.55 | 2.864 | 0.231 | 0.231 | No | PERIMETER_MID_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | WINDOW_U_0.5037_SHGC_SOUTH_0.23 | 59.33 | 0.00 | 0.00 | 59.33 | 59.33 | 2.864 | 0.231 | 0.231 | No | PERIMETER_MID_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | WINDOW_U_0.5037_SHGC_WEST_0.23 | 39.55 | 0.00 | 0.00 | 39.55 | 39.55 | 2.864 | 0.231 | 0.231 | No | PERIMETER_MID_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
Total or Average | 593.29 | 2.864 | 0.231 | 0.231 | |||||||||||||||||
North Total or Average | 177.99 | 2.864 | 0.231 | 0.231 | |||||||||||||||||
Non-North Total or Average | 415.31 | 2.864 | 0.231 | 0.231 |
Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
None |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_3_WALL_NORTH |
PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_3_WALL_NORTH |
PERIMETER_BOT_ZN_2_WALL_EAST_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_2_WALL_EAST |
PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_1_WALL_SOUTH |
PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_1_WALL_SOUTH |
PERIMETER_BOT_ZN_4_WALL_WEST_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_4_WALL_WEST |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
Interior LightingZone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
CORE_BOTTOM_LIGHTS | CORE_BOTTOM | CORE_BOTTOM | GENERAL | 5.9322 | 983.54 | 5834.49 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 44.13 | 0.0000 | Y | 48.33 |
CORE_MID_LIGHTS | CORE_MID | CORE_MID | GENERAL | 5.9322 | 983.54 | 5834.49 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 44.13 | 0.0000 | Y | 48.33 |
CORE_TOP_LIGHTS | CORE_TOP | CORE_TOP | GENERAL | 5.9322 | 983.54 | 5834.49 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 44.13 | 0.0000 | Y | 48.33 |
PERIMETER_TOP_ZN_3_LIGHTS | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3 | GENERAL | 5.9322 | 207.34 | 1229.96 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 25.27 | 0.0000 | Y | 5.83 |
PERIMETER_TOP_ZN_2_LIGHTS | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2 | GENERAL | 5.9322 | 131.26 | 778.67 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 25.40 | 0.0000 | Y | 3.71 |
PERIMETER_TOP_ZN_1_LIGHTS | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1 | GENERAL | 5.9322 | 207.34 | 1229.96 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 25.17 | 0.0000 | Y | 5.81 |
PERIMETER_TOP_ZN_4_LIGHTS | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4 | GENERAL | 5.9322 | 131.25 | 778.62 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 25.16 | 0.0000 | Y | 3.68 |
PERIMETER_BOT_ZN_3_LIGHTS | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3 | GENERAL | 5.9322 | 207.34 | 1229.96 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 25.22 | 0.0000 | Y | 5.82 |
PERIMETER_BOT_ZN_2_LIGHTS | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2 | GENERAL | 5.9322 | 131.26 | 778.67 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 25.35 | 0.0000 | Y | 3.71 |
PERIMETER_BOT_ZN_1_LIGHTS | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1 | GENERAL | 5.9322 | 207.34 | 1229.96 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 25.13 | 0.0000 | Y | 5.80 |
PERIMETER_BOT_ZN_4_LIGHTS | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4 | GENERAL | 5.9322 | 131.25 | 778.62 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 25.12 | 0.0000 | Y | 3.67 |
PERIMETER_MID_ZN_3_LIGHTS | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3 | GENERAL | 5.9322 | 207.34 | 1229.96 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 25.27 | 0.0000 | Y | 5.83 |
PERIMETER_MID_ZN_2_LIGHTS | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2 | GENERAL | 5.9322 | 131.26 | 778.67 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 25.40 | 0.0000 | Y | 3.71 |
PERIMETER_MID_ZN_1_LIGHTS | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1 | GENERAL | 5.9322 | 207.34 | 1229.96 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 25.17 | 0.0000 | Y | 5.81 |
PERIMETER_MID_ZN_4_LIGHTS | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4 | GENERAL | 5.9322 | 131.25 | 778.62 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 25.16 | 0.0000 | Y | 3.68 |
Interior Lighting Total | 5.9322 | 4982.19 | 29555.08 | 202.07 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
PERIMETER_BOT_ZN_1_DAYLREFPT1 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 1229.96 | 471.69 |
PERIMETER_BOT_ZN_1_DAYLREFPT2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 1229.96 | 171.58 |
PERIMETER_BOT_ZN_2_DAYLREFPT1 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 778.67 | 298.62 |
PERIMETER_BOT_ZN_2_DAYLREFPT2 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 778.67 | 108.62 |
PERIMETER_BOT_ZN_3_DAYLREFPT1 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 1229.96 | 471.69 |
PERIMETER_BOT_ZN_3_DAYLREFPT2 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 1229.96 | 171.58 |
PERIMETER_BOT_ZN_4_DAYLREFPT1 | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 778.62 | 298.60 |
PERIMETER_BOT_ZN_4_DAYLREFPT2 | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 778.62 | 108.62 |
PERIMETER_MID_ZN_1_DAYLREFPT1 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 1229.96 | 471.69 |
PERIMETER_MID_ZN_1_DAYLREFPT2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 1229.96 | 171.58 |
PERIMETER_MID_ZN_2_DAYLREFPT1 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 778.67 | 298.62 |
PERIMETER_MID_ZN_2_DAYLREFPT2 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 778.67 | 108.62 |
PERIMETER_MID_ZN_3_DAYLREFPT1 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 1229.96 | 471.69 |
PERIMETER_MID_ZN_3_DAYLREFPT2 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 1229.96 | 171.58 |
PERIMETER_MID_ZN_4_DAYLREFPT1 | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 778.62 | 298.60 |
PERIMETER_MID_ZN_4_DAYLREFPT2 | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 778.62 | 108.62 |
PERIMETER_TOP_ZN_1_DAYLREFPT1 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 1229.96 | 471.69 |
PERIMETER_TOP_ZN_1_DAYLREFPT2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 1229.96 | 171.58 |
PERIMETER_TOP_ZN_2_DAYLREFPT1 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 778.67 | 298.62 |
PERIMETER_TOP_ZN_2_DAYLREFPT2 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 778.67 | 108.62 |
PERIMETER_TOP_ZN_3_DAYLREFPT1 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 1229.96 | 471.69 |
PERIMETER_TOP_ZN_3_DAYLREFPT2 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 1229.96 | 171.58 |
PERIMETER_TOP_ZN_4_DAYLREFPT1 | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 778.62 | 298.60 |
PERIMETER_TOP_ZN_4_DAYLREFPT2 | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 778.62 | 108.62 |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS_A | 424.83 | AstronomicalClock | - | 41.93 | 41.93 | 3.34 | |
EXTERIOR_LIGHTS_B | 408.47 | AstronomicalClock | - | 83.83 | 62.88 | 4.82 | |
EXTERIOR_LIGHTS_C | 4724.13 | AstronomicalClock | - | 83.83 | 45.49 | 40.34 | |
Exterior Lighting Total | 5557.43 | 48.50 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
Central PlantType | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | 113842.41 | 79813.01 | 34029.41 | 0.70 | 3.40 | |||
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | 95319.58 | 66826.96 | 28492.62 | 0.70 | 3.40 | |||
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed | 115228.53 | 80784.79 | 34443.74 | 0.70 | 3.40 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
PACU_VAV_BOT COOLING COIL | 113656.5 | 2.97 | 10.14 | N/A | N/A | 11.65 | |
PACU_VAV_MID COOLING COIL | 95163.9 | 2.97 | 10.14 | N/A | N/A | 11.65 | |
PACU_VAV_TOP COOLING COIL | 115040.3 | 2.97 | 10.14 | N/A | N/A | 11.65 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | ||||||||
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | ||||||||
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
CORE_BOTTOM VAV BOX REHEAT COIL | Coil:Heating:Electric | 25445.72 | 1.00 | |
CORE_MID VAV BOX REHEAT COIL | Coil:Heating:Electric | 24182.77 | 1.00 | |
CORE_TOP VAV BOX REHEAT COIL | Coil:Heating:Electric | 25546.82 | 1.00 | |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | 5379.21 | 1.00 | |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | 4103.19 | 1.00 | |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | 5395.05 | 1.00 | |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | 4771.46 | 1.00 | |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | 5379.18 | 1.00 | |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | 3681.59 | 1.00 | |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | 5362.78 | 1.00 | |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | 3930.62 | 1.00 | |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | 5084.80 | 1.00 | |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | 3894.15 | 1.00 | |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | 5101.52 | 1.00 | |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | 4198.47 | 1.00 | |
PACU_VAV_BOT HEATING COIL | Coil:Heating:Fuel | 21291.30 | 0.80 | |
PACU_VAV_MID HEATING COIL | Coil:Heating:Fuel | 17827.08 | 0.80 | |
PACU_VAV_TOP HEATING COIL | Coil:Heating:Fuel | 21550.54 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
PACU_VAV_BOT FAN | Fan:VariableVolume | 0.60 | 1314.72 | 4.58 | 10035.38 | 2189.01 | 1.00 | 1.14 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 08:20:00 |
PACU_VAV_MID FAN | Fan:VariableVolume | 0.60 | 1314.72 | 3.84 | 8402.56 | 2189.01 | 1.00 | 1.15 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:50:00 |
PACU_VAV_TOP FAN | Fan:VariableVolume | 0.60 | 1314.72 | 4.64 | 10157.56 | 2189.01 | 1.00 | 1.14 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:30:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
SWHSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 3168.45 | 0.000054 | 0.73 | 13540.37 | 0.30 | General |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SWHSYS1 WATER HEATER | WaterHeater:Mixed | 0.38 | 29307.11 | 0.81 | 1.02 | 0.24 |
DX Cooling Coil Type | Assocated Fan | Net Cooling Capacity [W] | COP [W/W] | EER [Btu/W-h] | IEER [Btu/W-h] | Supply Air Flow 100% [kg/s] | COP 75% Capacity [W/W] | EER 75% Capacity [Btu/W-h] | Supply Air Flow 75% [kg/s] | COP 50% Capacity [W/W] | EER 50% Capacity [Btu/W-h] | Supply Air Flow 50% [kg/s] | COP 25% Capacity [W/W] | EER 25% Capacity [Btu/W-h] | Supply Air Flow 25% [kg/s] | |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | None | 113656.48 | 2.97 | 10.14 | 11.65 | 5.2999 | 3.34 | 11.39 | 4.1955 | 3.52 | 12.03 | 2.8233 | 3.64 | 12.43 | 1.2170 |
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | None | 95163.90 | 2.97 | 10.14 | 11.65 | 4.4376 | 3.34 | 11.39 | 3.5128 | 3.52 | 12.03 | 2.3640 | 3.64 | 12.43 | 1.0190 |
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed | None | 115040.33 | 2.97 | 10.14 | 11.65 | 5.3644 | 3.34 | 11.39 | 4.2465 | 3.52 | 12.03 | 2.8577 | 3.64 | 12.43 | 1.2318 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
CORE_BOTTOM | 37501.54 | 37501.54 | 38.13 | 2.703 | 2.703 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 08:00:00 | 24.00 | 24.00 | 0.00883 | 28.91 | 0.01715 | 0.425 | 0.00 |
CORE_MID | 27054.22 | 27054.22 | 27.51 | 1.947 | 1.947 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 08:00:00 | 24.00 | 24.00 | 0.00896 | 28.91 | 0.01715 | 0.425 | 0.00 |
CORE_TOP | 29489.32 | 29489.32 | 29.98 | 2.144 | 2.144 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:40:00 | 24.00 | 24.00 | 0.00891 | 35.20 | 0.01716 | 0.425 | 0.00 |
PERIMETER_TOP_ZN_3 | 9473.07 | 9473.07 | 45.69 | 0.689 | 0.689 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:20:00 | 24.00 | 24.00 | 0.00885 | 35.03 | 0.01716 | 0.090 | 0.00 |
PERIMETER_TOP_ZN_2 | 8454.37 | 8454.37 | 64.41 | 0.615 | 0.615 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 09:50:00 | 24.00 | 24.00 | 0.00876 | 31.73 | 0.01715 | 0.057 | 0.00 |
PERIMETER_TOP_ZN_1 | 9224.99 | 9224.99 | 44.49 | 0.671 | 0.671 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:50:00 | 24.00 | 24.00 | 0.00886 | 35.20 | 0.01716 | 0.090 | 0.00 |
PERIMETER_TOP_ZN_4 | 9831.32 | 9831.32 | 74.90 | 0.715 | 0.715 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 16:10:00 | 24.00 | 24.00 | 0.00872 | 34.58 | 0.01716 | 0.057 | 0.00 |
PERIMETER_BOT_ZN_3 | 7945.21 | 7945.21 | 38.32 | 0.578 | 0.578 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:20:00 | 24.00 | 24.00 | 0.00887 | 35.03 | 0.01716 | 0.090 | 0.00 |
PERIMETER_BOT_ZN_2 | 7585.78 | 7585.78 | 57.79 | 0.551 | 0.551 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 09:40:00 | 24.00 | 24.00 | 0.00875 | 31.49 | 0.01715 | 0.057 | 0.00 |
PERIMETER_BOT_ZN_1 | 7727.11 | 7727.11 | 37.27 | 0.562 | 0.562 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:30:00 | 24.00 | 24.00 | 0.00888 | 35.20 | 0.01716 | 0.090 | 0.00 |
PERIMETER_BOT_ZN_4 | 8098.92 | 8098.92 | 61.70 | 0.589 | 0.589 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 16:30:00 | 24.00 | 24.00 | 0.00873 | 34.35 | 0.01716 | 0.057 | 0.00 |
PERIMETER_MID_ZN_3 | 7937.05 | 7937.05 | 38.28 | 0.577 | 0.577 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:30:00 | 24.00 | 24.00 | 0.00890 | 34.95 | 0.01716 | 0.090 | 0.00 |
PERIMETER_MID_ZN_2 | 8023.70 | 8023.70 | 61.13 | 0.583 | 0.583 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 09:30:00 | 24.00 | 24.00 | 0.00876 | 31.25 | 0.01715 | 0.057 | 0.00 |
PERIMETER_MID_ZN_1 | 7728.93 | 7728.93 | 37.28 | 0.562 | 0.562 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:30:00 | 24.00 | 24.00 | 0.00892 | 35.20 | 0.01716 | 0.090 | 0.00 |
PERIMETER_MID_ZN_4 | 8650.73 | 8650.73 | 65.91 | 0.629 | 0.629 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 16:10:00 | 24.00 | 24.00 | 0.00874 | 34.58 | 0.01716 | 0.057 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
CORE_BOTTOM | 0.00 | 0.00 | 0.00 | 0.000 | 0.425 | 00:10:00 | 15.60 | 22.03 | 0.01480 | 20.10 | 0.01480 | 0.425 | 0.00 | |
CORE_MID | 1223.30 | 1223.30 | 1.24 | 0.052 | 0.425 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00800 | 20.10 | 0.01480 | 0.425 | 0.00 |
CORE_TOP | 5016.61 | 5016.61 | 5.10 | 0.211 | 0.425 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00800 | 20.10 | 0.01480 | 0.425 | 0.00 |
PERIMETER_TOP_ZN_3 | 1614.93 | 1614.93 | 7.79 | 0.068 | 0.090 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00923 | 20.10 | 0.01480 | 0.090 | 0.00 |
PERIMETER_TOP_ZN_2 | 1046.86 | 1046.86 | 7.98 | 0.044 | 0.057 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00927 | 20.10 | 0.01480 | 0.057 | 0.00 |
PERIMETER_TOP_ZN_1 | 1650.54 | 1650.54 | 7.96 | 0.069 | 0.090 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00921 | 20.10 | 0.01480 | 0.090 | 0.00 |
PERIMETER_TOP_ZN_4 | 1046.82 | 1046.82 | 7.98 | 0.044 | 0.057 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00927 | 20.10 | 0.01480 | 0.057 | 0.00 |
PERIMETER_BOT_ZN_3 | 96.45 | 96.45 | 0.47 | 0.004 | 0.090 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.01153 | 20.10 | 0.01480 | 0.090 | 0.00 |
PERIMETER_BOT_ZN_2 | 73.58 | 73.58 | 0.56 | 0.003 | 0.057 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.01126 | 20.10 | 0.01480 | 0.057 | 0.00 |
PERIMETER_BOT_ZN_1 | 127.68 | 127.68 | 0.62 | 0.005 | 0.090 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.01100 | 20.10 | 0.01480 | 0.090 | 0.00 |
PERIMETER_BOT_ZN_4 | 73.58 | 73.58 | 0.56 | 0.003 | 0.057 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.01126 | 20.10 | 0.01480 | 0.057 | 0.00 |
PERIMETER_MID_ZN_3 | 789.09 | 789.09 | 3.81 | 0.033 | 0.090 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00951 | 20.10 | 0.01480 | 0.090 | 0.00 |
PERIMETER_MID_ZN_2 | 522.28 | 522.28 | 3.98 | 0.022 | 0.057 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00953 | 20.10 | 0.01480 | 0.057 | 0.00 |
PERIMETER_MID_ZN_1 | 828.99 | 828.99 | 4.00 | 0.035 | 0.090 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00947 | 20.10 | 0.01480 | 0.090 | 0.00 |
PERIMETER_MID_ZN_4 | 522.27 | 522.27 | 3.98 | 0.022 | 0.057 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00953 | 20.10 | 0.01480 | 0.057 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PACU_VAV_BOT | 4.58 | 4.58 | 0.00 | 0.00 | 4.5844 | 1.3120 | 4.5844 | 0.2862 | 0.3000 |
PACU_VAV_MID | 3.84 | 3.84 | 0.00 | 0.00 | 3.8385 | 1.2720 | 3.8385 | 0.3314 | 0.3000 |
PACU_VAV_TOP | 4.64 | 4.64 | 0.00 | 0.00 | 4.6403 | 1.3539 | 4.6403 | 0.2918 | 0.3000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
CORE_BOTTOM VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_BOTTOM VAV BOX | 25445.721 | 25445.721 | -999.0 | -999.0 | -999.000 | 12/21 00:10:00 | 12/21 00:10:00 | 25445.72 | 14177.50 | 0.424691 | 12.80 | 11.59 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 0.0000 | 21.00 | 0.00800000 | 51.6928 | 0.00 | 0.00 | -999.00 | -999.00 | ||
CORE_MID VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_MID VAV BOX | 24182.770 | 24182.770 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 24182.77 | 14177.50 | 0.424691 | 12.80 | 11.59 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 0.0000 | 21.00 | 0.00800278 | 51.7105 | 1223.30 | 0.00 | -999.00 | -999.00 |
CORE_TOP VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_TOP VAV BOX | 25546.825 | 25546.825 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 25546.82 | 14177.50 | 0.424691 | 12.80 | 11.59 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 0.0000 | 21.00 | 0.00800000 | 51.6928 | 5016.61 | 0.00 | -999.00 | -999.00 |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_3 VAV BOX | 5379.211 | 5379.211 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 5379.21 | 2988.74 | 0.089529 | 12.80 | 11.59 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 0.0000 | 21.00 | 0.00923273 | 59.5383 | 1614.93 | 0.00 | -999.00 | -999.00 |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_2 VAV BOX | 4103.188 | 4103.188 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 4103.19 | 1892.12 | 0.056679 | 12.80 | 11.59 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 0.0000 | 21.00 | 0.00927087 | 59.7804 | 1046.86 | 0.00 | -999.00 | -999.00 |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_1 VAV BOX | 5395.045 | 5395.045 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 5395.05 | 2988.74 | 0.089529 | 12.80 | 11.59 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 0.0000 | 21.00 | 0.00921191 | 59.4060 | 1650.54 | 0.00 | -999.00 | -999.00 |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_4 VAV BOX | 4771.462 | 4771.462 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 4771.46 | 1892.00 | 0.056675 | 12.80 | 11.59 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 0.0000 | 21.00 | 0.00927091 | 59.7807 | 1046.82 | 0.00 | -999.00 | -999.00 |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_3 VAV BOX | 5379.182 | 5379.182 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 5379.18 | 2988.74 | 0.089529 | 12.80 | 11.59 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 0.0000 | 21.00 | 0.01153151 | 74.0959 | 96.45 | 0.00 | -999.00 | -999.00 |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_2 VAV BOX | 3681.586 | 3681.586 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 3681.59 | 1892.12 | 0.056679 | 12.80 | 11.59 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 0.0000 | 21.00 | 0.01125597 | 72.3568 | 73.58 | 0.00 | -999.00 | -999.00 |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_1 VAV BOX | 5362.783 | 5362.783 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 5362.78 | 2988.74 | 0.089529 | 12.80 | 11.59 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 0.0000 | 21.00 | 0.01100156 | 70.7499 | 127.68 | 0.00 | -999.00 | -999.00 |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_4 VAV BOX | 3930.624 | 3930.624 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 3930.62 | 1892.00 | 0.056675 | 12.80 | 11.59 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 0.0000 | 21.00 | 0.01125601 | 72.3571 | 73.58 | 0.00 | -999.00 | -999.00 |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_3 VAV BOX | 5084.802 | 5084.802 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 5084.80 | 2988.74 | 0.089529 | 12.80 | 11.59 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 0.0000 | 21.00 | 0.00950535 | 61.2715 | 789.09 | 0.00 | -999.00 | -999.00 |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_2 VAV BOX | 3894.154 | 3894.154 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 3894.15 | 1892.12 | 0.056679 | 12.80 | 11.59 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 0.0000 | 21.00 | 0.00953210 | 61.4412 | 522.28 | 0.00 | -999.00 | -999.00 |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_1 VAV BOX | 5101.520 | 5101.520 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 5101.52 | 2988.74 | 0.089529 | 12.80 | 11.59 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 0.0000 | 21.00 | 0.00946506 | 61.0156 | 828.99 | 0.00 | -999.00 | -999.00 |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_4 VAV BOX | 4198.472 | 4198.472 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 4198.47 | 1892.00 | 0.056675 | 12.80 | 11.59 | 0.00800000 | 40.00 | 21.18 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 0.0000 | 21.00 | 0.00953214 | 61.4414 | 522.27 | 0.00 | -999.00 | -999.00 |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoopHVAC | PACU_VAV_BOT | 113842.415 | 79813.007 | 4.584434 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 08:20:00 | 117051.20 | 82951.99 | 4.584434 | 26.93 | 19.41 | 0.01102319 | 11.03 | 11.03 | 0.00850000 | 35.20 | 0.01715815 | 25.83 | 26.0702 | 24.00 | 0.00884577 | 47.5725 | 62767.61 | 0.00 | 117386.81 | 81204.27 |
PACU_VAV_BOT HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PACU_VAV_BOT | 21291.305 | 21291.305 | -999.0 | -999.0 | -999.000 | unknown | unknown | unknown | 21291.30 | 21291.30 | 1.375330 | 0.00 | -6.26 | 0.00000000 | 12.80 | 11.59 | 0.00800000 | 0.00 | 0.00000000 | -6.26 | 86.9006 | -999.00 | -999.0 | -999.0000 | 0.00 | 0.00 | -999.00 | -999.00 | |
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoopHVAC | PACU_VAV_MID | 95319.585 | 66826.961 | 3.838520 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:50:00 | 99513.97 | 67586.89 | 3.838520 | 27.51 | 19.96 | 0.01150693 | 11.03 | 11.03 | 0.00850000 | 35.20 | 0.01715815 | 25.83 | 31.1362 | 24.00 | 0.00892889 | 48.0135 | 52483.08 | 0.00 | 98287.29 | 67991.86 |
PACU_VAV_MID HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PACU_VAV_MID | 17827.084 | 17827.084 | -999.0 | -999.0 | -999.000 | unknown | unknown | unknown | 17827.08 | 17827.08 | 1.151556 | 0.00 | -6.26 | 0.00000000 | 12.80 | 11.59 | 0.00800000 | 0.00 | 0.00000000 | -6.26 | 103.7874 | -999.00 | -999.0 | -999.0000 | 0.00 | 0.00 | -999.00 | -999.00 | |
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoopHVAC | PACU_VAV_TOP | 115228.525 | 80784.785 | 4.640253 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:30:00 | 118432.33 | 84028.46 | 4.640253 | 26.87 | 19.38 | 0.01100262 | 11.03 | 11.03 | 0.00850000 | 35.12 | 0.01715799 | 25.81 | 25.7566 | 24.00 | 0.00886092 | 47.6530 | 63696.21 | 0.00 | 118816.08 | 82192.99 |
PACU_VAV_TOP HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PACU_VAV_TOP | 21550.541 | 21550.541 | -999.0 | -999.0 | -999.000 | unknown | unknown | unknown | 21550.54 | 21550.54 | 1.392076 | 0.00 | -6.26 | 0.00000000 | 12.80 | 11.59 | 0.00800000 | 0.00 | 0.00000000 | -6.26 | 85.8552 | -999.00 | -999.0 | -999.0000 | 0.00 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
CORE_BOTTOM VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_BOTTOM VAV BOX | CORE_BOTTOM | N/A | N/A | N/A | Yes | No | unknown | No | 25445.721 | 25445.721 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | 12/21 00:10:00 | unknown | unknown | 12/21 00:10:00 | Sensible | 25445.72 | 14177.50 | 1.0000 | 0.51115607 | 0.424691 | 12.80 | 11.59 | 0.00800000 | 33059.8 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 25445.72 | 20.10 | 0.01479830 | 20.10 | 0.00000000 | 0.0000 | 21.00 | 0.00800000 | 21.00 | 0.00800000 | 51.6928 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |||
CORE_MID VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_MID VAV BOX | CORE_MID | N/A | N/A | N/A | Yes | No | unknown | No | 24182.770 | 24182.770 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 24182.77 | 14177.50 | 1.0000 | 0.51115607 | 0.424691 | 12.80 | 11.59 | 0.00800000 | 33059.8 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 24182.77 | 20.10 | 0.01479830 | 20.10 | 0.00000000 | 0.0000 | 20.87 | 0.00800278 | 21.00 | 0.00800278 | 51.7105 | 1223.30 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
CORE_TOP VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_TOP VAV BOX | CORE_TOP | N/A | N/A | N/A | Yes | No | unknown | No | 25546.825 | 25546.825 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 25546.82 | 14177.50 | 1.0000 | 0.51115607 | 0.424691 | 12.80 | 11.59 | 0.00800000 | 33059.8 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 25546.82 | 20.10 | 0.01479830 | 20.10 | 0.00000000 | 0.0000 | 20.68 | 0.00800000 | 21.00 | 0.00800000 | 51.6928 | 5016.61 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_3 VAV BOX | PERIMETER_TOP_ZN_3 | N/A | N/A | N/A | Yes | No | unknown | No | 5379.211 | 5379.211 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 5379.21 | 2988.74 | 1.0000 | 0.10775618 | 0.089529 | 12.80 | 11.59 | 0.00800000 | 33059.8 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5379.21 | 20.10 | 0.01479830 | 20.10 | 0.00000000 | 0.0000 | 20.56 | 0.00923273 | 21.00 | 0.00923273 | 59.5383 | 1614.93 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_2 VAV BOX | PERIMETER_TOP_ZN_2 | N/A | N/A | N/A | Yes | No | unknown | No | 4103.188 | 4103.188 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 4103.19 | 1892.12 | 1.0000 | 0.06821858 | 0.056679 | 12.80 | 11.59 | 0.00800000 | 33059.8 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 4103.19 | 20.10 | 0.01479830 | 20.10 | 0.00000000 | 0.0000 | 20.56 | 0.00927087 | 21.00 | 0.00927087 | 59.7804 | 1046.86 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_1 VAV BOX | PERIMETER_TOP_ZN_1 | N/A | N/A | N/A | Yes | No | unknown | No | 5395.045 | 5395.045 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 5395.05 | 2988.74 | 1.0000 | 0.10775618 | 0.089529 | 12.80 | 11.59 | 0.00800000 | 33059.8 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5395.05 | 20.10 | 0.01479830 | 20.10 | 0.00000000 | 0.0000 | 20.56 | 0.00921191 | 21.00 | 0.00921191 | 59.4060 | 1650.54 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_4 VAV BOX | PERIMETER_TOP_ZN_4 | N/A | N/A | N/A | Yes | No | unknown | No | 4771.462 | 4771.462 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 4771.46 | 1892.00 | 1.0000 | 0.06821410 | 0.056675 | 12.80 | 11.59 | 0.00800000 | 33059.8 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 4771.46 | 20.10 | 0.01479830 | 20.10 | 0.00000000 | 0.0000 | 20.56 | 0.00927091 | 21.00 | 0.00927091 | 59.7807 | 1046.82 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_3 VAV BOX | PERIMETER_BOT_ZN_3 | N/A | N/A | N/A | Yes | No | unknown | No | 5379.182 | 5379.182 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 5379.18 | 2988.74 | 1.0000 | 0.10775618 | 0.089529 | 12.80 | 11.59 | 0.00800000 | 33059.8 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5379.18 | 20.10 | 0.01479830 | 20.10 | 0.00000000 | 0.0000 | 20.97 | 0.01153151 | 21.00 | 0.01153151 | 74.0959 | 96.45 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_2 VAV BOX | PERIMETER_BOT_ZN_2 | N/A | N/A | N/A | Yes | No | unknown | No | 3681.586 | 3681.586 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 3681.59 | 1892.12 | 1.0000 | 0.06821858 | 0.056679 | 12.80 | 11.59 | 0.00800000 | 33059.8 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 3681.59 | 20.10 | 0.01479830 | 20.10 | 0.00000000 | 0.0000 | 20.97 | 0.01125597 | 21.00 | 0.01125597 | 72.3568 | 73.58 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_1 VAV BOX | PERIMETER_BOT_ZN_1 | N/A | N/A | N/A | Yes | No | unknown | No | 5362.783 | 5362.783 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 5362.78 | 2988.74 | 1.0000 | 0.10775618 | 0.089529 | 12.80 | 11.59 | 0.00800000 | 33059.8 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5362.78 | 20.10 | 0.01479830 | 20.10 | 0.00000000 | 0.0000 | 20.96 | 0.01100156 | 21.00 | 0.01100156 | 70.7499 | 127.68 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_4 VAV BOX | PERIMETER_BOT_ZN_4 | N/A | N/A | N/A | Yes | No | unknown | No | 3930.624 | 3930.624 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 3930.62 | 1892.00 | 1.0000 | 0.06821410 | 0.056675 | 12.80 | 11.59 | 0.00800000 | 33059.8 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 3930.62 | 20.10 | 0.01479830 | 20.10 | 0.00000000 | 0.0000 | 20.97 | 0.01125601 | 21.00 | 0.01125601 | 72.3571 | 73.58 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_3 VAV BOX | PERIMETER_MID_ZN_3 | N/A | N/A | N/A | Yes | No | unknown | No | 5084.802 | 5084.802 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 5084.80 | 2988.74 | 1.0000 | 0.10775618 | 0.089529 | 12.80 | 11.59 | 0.00800000 | 33059.8 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5084.80 | 20.10 | 0.01479830 | 20.10 | 0.00000000 | 0.0000 | 20.77 | 0.00950535 | 21.00 | 0.00950535 | 61.2715 | 789.09 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_2 VAV BOX | PERIMETER_MID_ZN_2 | N/A | N/A | N/A | Yes | No | unknown | No | 3894.154 | 3894.154 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 3894.15 | 1892.12 | 1.0000 | 0.06821858 | 0.056679 | 12.80 | 11.59 | 0.00800000 | 33059.8 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 3894.15 | 20.10 | 0.01479830 | 20.10 | 0.00000000 | 0.0000 | 20.77 | 0.00953210 | 21.00 | 0.00953210 | 61.4412 | 522.28 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_1 VAV BOX | PERIMETER_MID_ZN_1 | N/A | N/A | N/A | Yes | No | unknown | No | 5101.520 | 5101.520 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 5101.52 | 2988.74 | 1.0000 | 0.10775618 | 0.089529 | 12.80 | 11.59 | 0.00800000 | 33059.8 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5101.52 | 20.10 | 0.01479830 | 20.10 | 0.00000000 | 0.0000 | 20.76 | 0.00946506 | 21.00 | 0.00946506 | 61.0156 | 828.99 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_4 VAV BOX | PERIMETER_MID_ZN_4 | N/A | N/A | N/A | Yes | No | unknown | No | 4198.472 | 4198.472 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 4198.47 | 1892.00 | 1.0000 | 0.06821410 | 0.056675 | 12.80 | 11.59 | 0.00800000 | 33059.8 | 40.00 | 21.18 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 4198.47 | 20.10 | 0.01479830 | 20.10 | 0.00000000 | 0.0000 | 20.77 | 0.00953214 | 21.00 | 0.00953214 | 61.4414 | 522.27 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoop | AirLoopHVAC | PACU_VAV_BOT | CORE_BOTTOM; PERIMETER_BOT_ZN_1; PERIMETER_BOT_ZN_2; PERIMETER_BOT_ZN_3; PERIMETER_BOT_ZN_4; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 113842.415 | 79813.007 | 4.584434 | -999.0 | -999.000 | -999.0000 | 1.00000 | 0.97115 | 1025.3316 | 1004.8586 | 1.2036 | PACU_VAV_BOT FAN | Fan:VariableVolume | 4.584434 | 5.51780182 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 08:20:00 | Sensible | 117051.20 | 82951.99 | 1.0282 | 5.51780182 | 4.584434 | 26.93 | 19.41 | 0.01102319 | 55183.5 | 11.03 | 11.03 | 0.00850000 | 32511.8 | -999.0 | -999.00 | -999.00 | -999.00 | 10035.377 | 107015.82 | 35.20 | 0.01715815 | 25.83 | 1.19517000 | 26.0702 | 24.00 | 0.00884577 | 24.00 | 0.00884577 | 47.5725 | 62767.61 | 0.00 | 117386.81 | 81204.27 | 5.29989036 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 11.65 | 11.63 | 0.00850793 | 33173.5 | |
PACU_VAV_BOT HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PACU_VAV_BOT | CORE_BOTTOM; PERIMETER_BOT_ZN_1; PERIMETER_BOT_ZN_2; PERIMETER_BOT_ZN_3; PERIMETER_BOT_ZN_4; | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 21291.305 | 21291.305 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | PACU_VAV_BOT FAN | Fan:VariableVolume | 4.584434 | 5.51780182 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | unknown | unknown | unknown | unknown | unknown | Sensible | 21291.30 | 21291.30 | 1.0000 | 1.65534055 | 1.375330 | 0.00 | -6.26 | 0.00000000 | 25.0 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 21291.30 | 0.00 | 0.00000000 | -6.26 | 1.19517000 | 86.9006 | 0.00 | 0.00000000 | -999.00 | -999.0 | -999.0000 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | ||
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoop | AirLoopHVAC | PACU_VAV_MID | CORE_MID; PERIMETER_MID_ZN_1; PERIMETER_MID_ZN_2; PERIMETER_MID_ZN_3; PERIMETER_MID_ZN_4; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 95319.585 | 66826.961 | 3.838520 | -999.0 | -999.000 | -999.0000 | 1.00000 | 0.91518 | 1026.2308 | 1004.8586 | 1.2036 | PACU_VAV_MID FAN | Fan:VariableVolume | 3.838520 | 4.62002302 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:50:00 | Sensible | 99513.97 | 67586.89 | 1.0440 | 4.62002302 | 3.838520 | 27.51 | 19.96 | 0.01150693 | 57007.5 | 11.03 | 11.03 | 0.00850000 | 32513.4 | -999.0 | -999.00 | -999.00 | -999.00 | 8402.562 | 91111.41 | 35.20 | 0.01715815 | 25.83 | 1.19517000 | 31.1362 | 24.00 | 0.00892889 | 24.00 | 0.00892889 | 48.0135 | 52483.08 | 0.00 | 98287.29 | 67991.86 | 4.43756703 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 11.65 | 11.63 | 0.00850793 | 33173.5 | |
PACU_VAV_MID HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PACU_VAV_MID | CORE_MID; PERIMETER_MID_ZN_1; PERIMETER_MID_ZN_2; PERIMETER_MID_ZN_3; PERIMETER_MID_ZN_4; | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 17827.084 | 17827.084 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | PACU_VAV_MID FAN | Fan:VariableVolume | 3.838520 | 4.62002302 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | unknown | unknown | unknown | unknown | unknown | Sensible | 17827.08 | 17827.08 | 1.0000 | 1.38600691 | 1.151556 | 0.00 | -6.26 | 0.00000000 | 25.0 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 17827.08 | 0.00 | 0.00000000 | -6.26 | 1.19517000 | 103.7874 | 0.00 | 0.00000000 | -999.00 | -999.0 | -999.0000 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | ||
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoop | AirLoopHVAC | PACU_VAV_TOP | CORE_TOP; PERIMETER_TOP_ZN_1; PERIMETER_TOP_ZN_2; PERIMETER_TOP_ZN_3; PERIMETER_TOP_ZN_4; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 115228.525 | 80784.785 | 4.640253 | -999.0 | -999.000 | -999.0000 | 1.00000 | 0.97567 | 1025.2933 | 1004.8586 | 1.2036 | PACU_VAV_TOP FAN | Fan:VariableVolume | 4.640253 | 5.58498487 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:30:00 | Sensible | 118432.33 | 84028.46 | 1.0278 | 5.58498487 | 4.640253 | 26.87 | 19.38 | 0.01100262 | 55064.6 | 11.03 | 11.03 | 0.00850000 | 32511.7 | -999.0 | -999.00 | -999.00 | -999.00 | 10157.564 | 108274.76 | 35.12 | 0.01715799 | 25.81 | 1.19517000 | 25.7566 | 24.00 | 0.00886092 | 24.00 | 0.00886092 | 47.6530 | 63696.21 | 0.00 | 118816.08 | 82192.99 | 5.36442019 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 11.65 | 11.63 | 0.00850793 | 33173.5 | |
PACU_VAV_TOP HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PACU_VAV_TOP | CORE_TOP; PERIMETER_TOP_ZN_1; PERIMETER_TOP_ZN_2; PERIMETER_TOP_ZN_3; PERIMETER_TOP_ZN_4; | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 21550.541 | 21550.541 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | PACU_VAV_TOP FAN | Fan:VariableVolume | 4.640253 | 5.58498487 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | unknown | unknown | unknown | unknown | unknown | Sensible | 21550.54 | 21550.54 | 1.0000 | 1.67549546 | 1.392076 | 0.00 | -6.26 | 0.00000000 | 25.0 | 12.80 | 11.59 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 21550.54 | 0.00 | 0.00000000 | -6.26 | 1.19517000 | 85.8552 | 0.00 | 0.00000000 | -999.00 | -999.0 | -999.0000 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
CORE_BOTTOM | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
CORE_MID | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
CORE_TOP | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_3 | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_2 | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_1 | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_4 | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
CORE_BOTTOM | 5937.17 | 0.00 | 0.00 |
CORE_MID | 4876.17 | 12.83 | 0.00 |
CORE_TOP | 4952.83 | 57.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 5615.67 | 279.00 | 238.83 |
PERIMETER_TOP_ZN_2 | 5654.00 | 484.67 | 463.00 |
PERIMETER_TOP_ZN_1 | 5736.67 | 376.83 | 370.83 |
PERIMETER_TOP_ZN_4 | 5317.67 | 445.83 | 301.00 |
PERIMETER_BOT_ZN_3 | 5907.00 | 51.33 | 51.17 |
PERIMETER_BOT_ZN_2 | 5940.00 | 243.83 | 243.83 |
PERIMETER_BOT_ZN_1 | 5940.00 | 1708.50 | 1708.50 |
PERIMETER_BOT_ZN_4 | 5920.83 | 186.33 | 186.17 |
PERIMETER_MID_ZN_3 | 5761.67 | 96.83 | 95.00 |
PERIMETER_MID_ZN_2 | 4823.17 | 287.83 | 286.67 |
PERIMETER_MID_ZN_1 | 5854.67 | 215.33 | 215.33 |
PERIMETER_MID_ZN_4 | 5592.67 | 230.17 | 218.83 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 |
Facility | 5942.33 | 2270.17 | 2152.83 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
CORE_BOTTOM | 0.00 | 0.33 | 0.00 | 0.00 |
CORE_MID | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 0.00 | 36.67 | 0.00 | 33.00 |
PERIMETER_TOP_ZN_2 | 0.00 | 80.50 | 0.00 | 79.00 |
PERIMETER_TOP_ZN_1 | 0.00 | 75.83 | 0.00 | 74.00 |
PERIMETER_TOP_ZN_4 | 0.00 | 60.33 | 0.00 | 50.33 |
PERIMETER_BOT_ZN_3 | 0.00 | 8.67 | 0.00 | 7.67 |
PERIMETER_BOT_ZN_2 | 0.00 | 43.83 | 0.00 | 43.50 |
PERIMETER_BOT_ZN_1 | 0.00 | 725.83 | 0.00 | 725.50 |
PERIMETER_BOT_ZN_4 | 0.00 | 42.50 | 0.00 | 35.50 |
PERIMETER_MID_ZN_3 | 0.00 | 11.50 | 0.00 | 10.50 |
PERIMETER_MID_ZN_2 | 0.00 | 42.67 | 0.00 | 42.67 |
PERIMETER_MID_ZN_1 | 0.00 | 75.33 | 0.00 | 75.33 |
PERIMETER_MID_ZN_4 | 0.00 | 43.17 | 0.00 | 37.33 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 0.00 | 850.67 | 0.00 | 838.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
CORE_BOTTOM | 21.49 | 52.94 | 2698.04 | 0.467 | 0.000 | 0.000 | 0.000 |
CORE_MID | 21.49 | 52.94 | 2698.04 | 0.447 | 0.000 | 0.000 | 0.000 |
CORE_TOP | 21.49 | 52.94 | 2698.04 | 0.444 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_3 | 4.53 | 11.16 | 568.77 | 0.628 | 0.014 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_2 | 2.87 | 7.07 | 360.08 | 0.772 | 0.014 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_1 | 4.53 | 11.16 | 568.77 | 0.684 | 0.014 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_4 | 2.87 | 7.06 | 360.05 | 0.779 | 0.014 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_3 | 4.53 | 11.16 | 568.77 | 0.539 | 0.007 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_2 | 2.87 | 7.07 | 360.08 | 0.652 | 0.008 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_1 | 4.53 | 11.16 | 568.77 | 0.677 | 1.223 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_4 | 2.87 | 7.06 | 360.05 | 0.650 | 0.008 | 0.000 | 0.000 |
PERIMETER_MID_ZN_3 | 4.53 | 11.16 | 568.77 | 0.635 | 0.011 | 0.000 | 0.000 |
PERIMETER_MID_ZN_2 | 2.51 | 7.07 | 360.08 | 0.728 | 0.013 | 0.000 | 0.000 |
PERIMETER_MID_ZN_1 | 4.53 | 11.16 | 568.77 | 0.689 | 0.011 | 0.000 | 0.000 |
PERIMETER_MID_ZN_4 | 2.87 | 7.06 | 360.05 | 0.776 | 0.012 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
CORE_BOTTOM | 21.49 | 52.94 | 2698.04 | 0.000 | 0.000 | 0.000 | 0.000 |
CORE_MID | 21.49 | 52.94 | 2698.04 | 0.000 | 0.000 | 0.000 | 0.000 |
CORE_TOP | 21.49 | 52.94 | 2698.04 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_3 | 4.53 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_2 | 2.87 | 7.07 | 360.08 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_1 | 4.53 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_4 | 2.87 | 7.06 | 360.05 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_3 | 4.53 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_2 | 2.87 | 7.07 | 360.08 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_1 | 4.53 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_4 | 2.87 | 7.06 | 360.05 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_3 | 4.53 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_2 | 2.51 | 7.07 | 360.08 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_1 | 4.53 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_4 | 2.87 | 7.06 | 360.05 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
Mechanical Ventilation Parameters by ZoneAirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
CORE_BOTTOM | PACU_VAV_BOT | 21.49 | 52.94 | 2698.04 | 983.54 | 0.0000 | 0.425 |
CORE_MID | PACU_VAV_MID | 21.49 | 52.94 | 2698.04 | 983.54 | 0.0000 | 0.425 |
CORE_TOP | PACU_VAV_TOP | 21.49 | 52.94 | 2698.04 | 983.54 | 0.0000 | 0.425 |
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP | 4.53 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP | 2.87 | 7.07 | 360.08 | 131.26 | 0.0000 | 0.057 |
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP | 4.53 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP | 2.87 | 7.06 | 360.05 | 131.25 | 0.0000 | 0.057 |
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT | 4.53 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT | 2.87 | 7.07 | 360.08 | 131.26 | 0.0000 | 0.057 |
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT | 4.53 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT | 2.87 | 7.06 | 360.05 | 131.25 | 0.0000 | 0.057 |
PERIMETER_MID_ZN_3 | PACU_VAV_MID | 4.53 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_MID_ZN_2 | PACU_VAV_MID | 2.51 | 7.07 | 360.08 | 131.26 | 0.0000 | 0.057 |
PERIMETER_MID_ZN_1 | PACU_VAV_MID | 4.53 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_MID_ZN_4 | PACU_VAV_MID | 2.87 | 7.06 | 360.05 | 131.25 | 0.0000 | 0.057 |
Total Facility | 108.48 | 268.17 | 13667.13 | 4982.19 | 0.0000 | 2.151 |
Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
CORE_BOTTOM | 7760168.46 | 0.00 | 7760168.46 | 0.00 | 7760168.46 | 13393058.27 | 7226.62 | 1069.46 | 463.92 | 318.34 |
CORE_MID | 7252080.34 | 0.00 | 7252080.34 | 0.00 | 7252080.34 | 13393058.27 | 8606.21 | 139.36 | 14.43 | 197.54 |
CORE_TOP | 7215793.97 | 0.00 | 7215793.97 | 0.00 | 7215793.97 | 13393058.27 | 8747.57 | 1.91 | 10.52 | 210.82 |
PERIMETER_TOP_ZN_3 | 2124759.58 | 0.00 | 2124759.58 | 82569.24 | 2207328.82 | 2823374.22 | 4900.40 | 47.06 | 3812.54 | 210.82 |
PERIMETER_TOP_ZN_2 | 1650397.14 | 0.00 | 1650397.14 | 55045.83 | 1705442.97 | 1787429.43 | 3454.68 | 1.67 | 5303.65 | 210.82 |
PERIMETER_TOP_ZN_1 | 2306577.86 | 0.00 | 2306577.86 | 82569.24 | 2389147.10 | 2823374.22 | 4673.81 | 41.38 | 4044.81 | 210.82 |
PERIMETER_TOP_ZN_4 | 1676170.56 | 0.00 | 1676170.56 | 55045.83 | 1731216.39 | 1787312.18 | 3467.16 | 6.61 | 5286.23 | 210.82 |
PERIMETER_BOT_ZN_3 | 1866241.46 | 0.00 | 1866241.46 | 43902.08 | 1910143.53 | 2823374.22 | 4833.29 | 1212.69 | 2714.02 | 318.34 |
PERIMETER_BOT_ZN_2 | 1420987.60 | 0.00 | 1420987.60 | 29267.87 | 1450255.47 | 1787429.43 | 3464.43 | 59.51 | 5236.06 | 318.34 |
PERIMETER_BOT_ZN_1 | 2309692.87 | 0.00 | 2309692.87 | 3989601.53 | 6299294.40 | 2823374.22 | 3583.95 | 974.38 | 4201.67 | 318.34 |
PERIMETER_BOT_ZN_4 | 1423031.80 | 0.00 | 1423031.80 | 29267.87 | 1452299.68 | 1787312.18 | 3760.42 | 102.70 | 4896.88 | 318.34 |
PERIMETER_MID_ZN_3 | 2141079.23 | 0.00 | 2141079.23 | 68732.90 | 2209812.13 | 2823374.22 | 4742.12 | 67.98 | 3949.89 | 197.54 |
PERIMETER_MID_ZN_2 | 1636323.98 | 0.00 | 1636323.98 | 45821.66 | 1682145.64 | 1787429.43 | 3478.35 | 1.72 | 5279.93 | 1106.54 |
PERIMETER_MID_ZN_1 | 2319992.92 | 0.00 | 2319992.92 | 68732.90 | 2388725.82 | 2823374.22 | 4354.12 | 237.01 | 4168.87 | 197.54 |
PERIMETER_MID_ZN_4 | 1661997.00 | 0.00 | 1661997.00 | 45821.66 | 1707818.66 | 1787312.18 | 3493.79 | 8.18 | 5258.03 | 197.54 |
Total Facility | 44765294.76 | 0.00 | 44765294.76 | 4596378.61 | 49361673.36 | 67843644.98 | 8760.00 | 1719.45 | 5569.43 | 1301.36 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
CORE_BOTTOM | 0.3396 | 0.0000 | 0.3396 | 0.0000 | 0.3396 | 0.4247 | 4706.55 | 793.83 | 442.63 |
CORE_MID | 0.3250 | 0.0000 | 0.3250 | 0.0000 | 0.3250 | 0.4247 | 5799.34 | 134.79 | 8.86 |
CORE_TOP | 0.3225 | 0.0000 | 0.3225 | 0.0000 | 0.3225 | 0.4247 | 5933.86 | 1.63 | 7.51 |
PERIMETER_TOP_ZN_3 | 0.0961 | 0.0000 | 0.0961 | 0.0021 | 0.0982 | 0.0895 | 2095.68 | 46.32 | 3801.01 |
PERIMETER_TOP_ZN_2 | 0.0748 | 0.0000 | 0.0748 | 0.0014 | 0.0762 | 0.0567 | 846.57 | 1.12 | 5095.32 |
PERIMETER_TOP_ZN_1 | 0.1046 | 0.0000 | 0.1046 | 0.0021 | 0.1067 | 0.0895 | 1867.37 | 40.97 | 4034.66 |
PERIMETER_TOP_ZN_4 | 0.0755 | 0.0000 | 0.0755 | 0.0014 | 0.0769 | 0.0567 | 860.44 | 6.36 | 5076.20 |
PERIMETER_BOT_ZN_3 | 0.0825 | 0.0000 | 0.0825 | 0.0011 | 0.0836 | 0.0895 | 2297.62 | 935.26 | 2710.12 |
PERIMETER_BOT_ZN_2 | 0.0632 | 0.0000 | 0.0632 | 0.0007 | 0.0639 | 0.0567 | 952.49 | 54.73 | 4935.78 |
PERIMETER_BOT_ZN_1 | 0.1032 | 0.0000 | 0.1032 | 0.1855 | 0.2887 | 0.0895 | 1051.82 | 699.29 | 4191.90 |
PERIMETER_BOT_ZN_4 | 0.0629 | 0.0000 | 0.0629 | 0.0007 | 0.0637 | 0.0567 | 1254.15 | 102.49 | 4586.36 |
PERIMETER_MID_ZN_3 | 0.0971 | 0.0000 | 0.0971 | 0.0017 | 0.0989 | 0.0895 | 1933.63 | 67.20 | 3942.17 |
PERIMETER_MID_ZN_2 | 0.0705 | 0.0000 | 0.0705 | 0.0012 | 0.0717 | 0.0567 | 855.18 | 0.72 | 4178.09 |
PERIMETER_MID_ZN_1 | 0.1055 | 0.0000 | 0.1055 | 0.0017 | 0.1072 | 0.0895 | 1553.23 | 228.91 | 4160.87 |
PERIMETER_MID_ZN_4 | 0.0752 | 0.0000 | 0.0752 | 0.0012 | 0.0763 | 0.0567 | 872.73 | 7.88 | 5062.39 |
Total Facility | 1.9982 | 0.0000 | 1.9982 | 0.2010 | 2.1992 | 2.1513 | 5943.00 | 1433.33 | 5177.07 |
Mechanical Ventilation [m3] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
PACU_VAV_BOT | 21411094.97 | 0.00 | 21411094.97 | 22614548.33 | 3342.82 | 0.00 | 5417.18 | 318.34 |
PACU_VAV_MID | 21746245.54 | 0.00 | 21746245.54 | 22614548.33 | 3467.49 | 0.00 | 5292.51 | 197.54 |
PACU_VAV_TOP | 21691523.86 | 0.00 | 21691523.86 | 22614548.33 | 3446.30 | 0.00 | 5313.70 | 210.82 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
PACU_VAV_BOT | 0.9436 | 0.0000 | 0.9436 | 0.7171 | 844.16 | 0.00 | 5098.84 |
PACU_VAV_MID | 0.9807 | 0.0000 | 0.9807 | 0.7171 | 848.02 | 0.00 | 5094.98 |
PACU_VAV_TOP | 0.9757 | 0.0000 | 0.9757 | 0.7171 | 840.12 | 0.00 | 5102.88 |
No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
PACU_VAV_BOT | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5417.18 | 0.00 | 0.00 | 0.00 |
PACU_VAV_MID | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5292.51 | 0.00 | 0.00 | 0.00 |
PACU_VAV_TOP | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5313.70 | 0.00 | 0.00 | 0.00 |
No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
PACU_VAV_BOT | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.1000 | 0.0000 | 0.0000 | 0.0000 |
PACU_VAV_MID | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.1442 | 0.0000 | 0.0000 | 0.0000 |
PACU_VAV_TOP | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.1366 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
Surfaces by ClassTotal | Outdoors | |
Wall | 72 | 24 |
Floor | 30 | 4 |
Roof | 26 | 1 |
Internal Mass | 15 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 18 | 18 |
Door | 6 | 6 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 3 |
Conditioned Zones | 18 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 3 |
Count | |
IDF Objects | 827 |
Defaulted Fields | 545 |
Fields with Defaults | 2238 |
Autosized Fields | 150 |
Autosizable Fields | 203 |
Autocalculated Fields | 155 |
Autocalculatable Fields | 276 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 1966.10 | 12357.78 | 11-JUN-17:10 | 162130.67 | 13-JUN-15:20 |
Electricity:Building | 907.50 | 12188.95 | 04-JUL-17:10 | 63350.34 | 23-OCT-07:10 |
Electricity:Zone:CORE_BOTTOM | 284.50 | 4029.56 | 01-JAN-00:10 | 22405.39 | 02-JAN-08:10 |
Electricity:SpaceType:GENERAL | 907.50 | 12188.95 | 04-JUL-17:10 | 63350.34 | 23-OCT-07:10 |
InteriorLights:Electricity | 202.07 | 934.27 | 01-JAN-09:20 | 19951.89 | 18-DEC-17:00 |
InteriorLights:Electricity:Zone:CORE_BOTTOM | 48.33 | 234.43 | 01-JAN-00:10 | 4220.20 | 02-JAN-08:10 |
InteriorLights:Electricity:SpaceType:GENERAL | 202.07 | 934.27 | 01-JAN-09:20 | 19951.89 | 18-DEC-17:00 |
LightsWired:InteriorLights:Electricity | 202.07 | 934.27 | 01-JAN-09:20 | 19951.89 | 18-DEC-17:00 |
LightsWired:InteriorLights:Electricity:Zone:CORE_BOTTOM | 48.33 | 234.43 | 01-JAN-00:10 | 4220.20 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:SpaceType:GENERAL | 202.07 | 934.27 | 01-JAN-09:20 | 19951.89 | 18-DEC-17:00 |
Electricity:Zone:CORE_MID | 163.76 | 2065.97 | 01-JAN-00:10 | 11028.52 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:CORE_MID | 48.33 | 234.43 | 01-JAN-00:10 | 4220.20 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:CORE_MID | 48.33 | 234.43 | 01-JAN-00:10 | 4220.20 | 02-JAN-08:10 |
Electricity:Zone:CORE_TOP | 163.76 | 2065.97 | 01-JAN-00:10 | 11028.52 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:CORE_TOP | 48.33 | 234.43 | 01-JAN-00:10 | 4220.20 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:CORE_TOP | 48.33 | 234.43 | 01-JAN-00:10 | 4220.20 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_TOP_ZN_3 | 30.17 | 409.68 | 07-MAY-17:10 | 2199.99 | 18-DEC-17:00 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_3 | 5.83 | 23.57 | 01-JAN-08:50 | 764.74 | 18-DEC-17:00 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_3 | 5.83 | 23.57 | 01-JAN-08:50 | 764.74 | 18-DEC-17:00 |
Electricity:Zone:PERIMETER_TOP_ZN_2 | 19.12 | 261.28 | 04-JUL-17:10 | 1398.69 | 18-DEC-17:00 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_2 | 3.71 | 14.92 | 01-JAN-07:20 | 490.12 | 18-DEC-17:00 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_2 | 3.71 | 14.92 | 01-JAN-07:20 | 490.12 | 18-DEC-17:00 |
Electricity:Zone:PERIMETER_TOP_ZN_1 | 30.14 | 412.01 | 26-MAR-17:10 | 2165.18 | 18-DEC-17:00 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_1 | 5.81 | 23.57 | 01-JAN-07:50 | 729.94 | 18-DEC-17:00 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_1 | 5.81 | 23.57 | 01-JAN-07:50 | 729.94 | 18-DEC-17:00 |
Electricity:Zone:PERIMETER_TOP_ZN_4 | 19.08 | 259.34 | 12-MAR-17:10 | 1361.89 | 18-DEC-17:00 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_4 | 3.68 | 14.92 | 01-JAN-09:20 | 453.32 | 18-DEC-17:00 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_4 | 3.68 | 14.92 | 01-JAN-09:20 | 453.32 | 18-DEC-17:00 |
Electricity:Zone:PERIMETER_BOT_ZN_3 | 30.16 | 409.68 | 07-MAY-17:10 | 2194.30 | 18-DEC-17:00 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_3 | 5.82 | 23.57 | 01-JAN-08:40 | 759.05 | 18-DEC-17:00 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_3 | 5.82 | 23.57 | 01-JAN-08:40 | 759.05 | 18-DEC-17:00 |
Electricity:Zone:PERIMETER_BOT_ZN_2 | 19.11 | 260.91 | 11-NOV-06:00 | 1396.06 | 18-DEC-17:00 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_2 | 3.71 | 14.92 | 01-JAN-07:20 | 487.48 | 18-DEC-17:00 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_2 | 3.71 | 14.92 | 01-JAN-07:20 | 487.48 | 18-DEC-17:00 |
Electricity:Zone:PERIMETER_BOT_ZN_1 | 30.13 | 411.77 | 26-MAR-17:10 | 2157.79 | 18-DEC-17:00 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_1 | 5.80 | 23.57 | 01-JAN-07:50 | 722.55 | 18-DEC-17:00 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_1 | 5.80 | 23.57 | 01-JAN-07:50 | 722.55 | 18-DEC-17:00 |
Electricity:Zone:PERIMETER_BOT_ZN_4 | 19.07 | 259.34 | 12-MAR-17:10 | 1354.54 | 18-DEC-17:00 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_4 | 3.67 | 14.92 | 01-JAN-09:00 | 445.97 | 18-DEC-17:00 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_4 | 3.67 | 14.92 | 01-JAN-09:00 | 445.97 | 18-DEC-17:00 |
Electricity:Zone:PERIMETER_MID_ZN_3 | 30.17 | 409.68 | 07-MAY-17:10 | 2199.98 | 18-DEC-17:00 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_3 | 5.83 | 23.57 | 01-JAN-08:50 | 764.73 | 18-DEC-17:00 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_3 | 5.83 | 23.57 | 01-JAN-08:50 | 764.73 | 18-DEC-17:00 |
Electricity:Zone:PERIMETER_MID_ZN_2 | 19.12 | 261.28 | 04-JUL-17:10 | 1398.69 | 18-DEC-17:00 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_2 | 3.71 | 14.92 | 01-JAN-07:20 | 490.11 | 18-DEC-17:00 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_2 | 3.71 | 14.92 | 01-JAN-07:20 | 490.11 | 18-DEC-17:00 |
Electricity:Zone:PERIMETER_MID_ZN_1 | 30.14 | 412.01 | 26-MAR-17:10 | 2165.17 | 18-DEC-17:00 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_1 | 5.81 | 23.57 | 01-JAN-07:50 | 729.93 | 18-DEC-17:00 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_1 | 5.81 | 23.57 | 01-JAN-07:50 | 729.93 | 18-DEC-17:00 |
Electricity:Zone:PERIMETER_MID_ZN_4 | 19.08 | 259.34 | 12-MAR-17:10 | 1361.88 | 18-DEC-17:00 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_4 | 3.68 | 14.92 | 01-JAN-09:20 | 453.32 | 18-DEC-17:00 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_4 | 3.68 | 14.92 | 01-JAN-09:20 | 453.32 | 18-DEC-17:00 |
InteriorEquipment:Electricity | 705.43 | 11241.34 | 01-JAN-00:10 | 45864.70 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:CORE_BOTTOM | 236.17 | 3795.13 | 01-JAN-00:10 | 18185.19 | 02-JAN-08:10 |
InteriorEquipment:Electricity:SpaceType:GENERAL | 705.43 | 11241.34 | 01-JAN-00:10 | 45864.70 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity | 584.69 | 9277.75 | 01-JAN-00:10 | 34487.83 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_BOTTOM | 115.43 | 1831.54 | 01-JAN-00:10 | 6808.32 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL | 584.69 | 9277.75 | 01-JAN-00:10 | 34487.83 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:CORE_MID | 115.43 | 1831.54 | 01-JAN-00:10 | 6808.32 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_MID | 115.43 | 1831.54 | 01-JAN-00:10 | 6808.32 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:CORE_TOP | 115.43 | 1831.54 | 01-JAN-00:10 | 6808.32 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_TOP | 115.43 | 1831.54 | 01-JAN-00:10 | 6808.32 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
ElevatorLift:InteriorEquipment:Electricity | 120.10 | 1963.59 | 01-JAN-00:10 | 11290.62 | 02-JAN-08:10 |
ElevatorLift:InteriorEquipment:Electricity:Zone:CORE_BOTTOM | 120.10 | 1963.59 | 01-JAN-00:10 | 11290.62 | 02-JAN-08:10 |
ElevatorLift:InteriorEquipment:Electricity:SpaceType:GENERAL | 120.10 | 1963.59 | 01-JAN-00:10 | 11290.62 | 02-JAN-08:10 |
ElevatorLightsFan:InteriorEquipment:Electricity | 0.64 | 0.00 | 01-JAN-00:10 | 86.25 | 02-JAN-08:10 |
ElevatorLightsFan:InteriorEquipment:Electricity:Zone:CORE_BOTTOM | 0.64 | 0.00 | 01-JAN-00:10 | 86.25 | 02-JAN-08:10 |
ElevatorLightsFan:InteriorEquipment:Electricity:SpaceType:GENERAL | 0.64 | 0.00 | 01-JAN-00:10 | 86.25 | 02-JAN-08:10 |
Electricity:HVAC | 1010.08 | 168.34 | 01-JAN-00:10 | 103238.83 | 13-JUN-15:20 |
ExteriorEquipment:Electricity | 11.65 | 168.34 | 01-JAN-00:10 | 831.86 | 18-DEC-17:00 |
Transformer:ExteriorEquipment:Electricity | 11.65 | 168.34 | 01-JAN-00:10 | 831.86 | 18-DEC-17:00 |
ElectricityPurchased:Facility | 1966.10 | 12357.78 | 11-JUN-17:10 | 162130.67 | 13-JUN-15:20 |
ElectricityPurchased:Plant | 1966.10 | 12357.78 | 11-JUN-17:10 | 162130.67 | 13-JUN-15:20 |
Cogeneration:ElectricityPurchased | 1966.10 | 12357.78 | 11-JUN-17:10 | 162130.67 | 13-JUN-15:20 |
General:Cogeneration:ElectricityPurchased | 1966.10 | 12357.78 | 11-JUN-17:10 | 162130.67 | 13-JUN-15:20 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 1966.10 | 12357.78 | 11-JUN-17:10 | 162130.67 | 13-JUN-15:20 |
ElectricityNet:Plant | 1966.10 | 12357.78 | 11-JUN-17:10 | 162130.67 | 13-JUN-15:20 |
Cogeneration:ElectricityNet | 1966.10 | 12357.78 | 11-JUN-17:10 | 162130.67 | 13-JUN-15:20 |
General:Cogeneration:ElectricityNet | 1966.10 | 12357.78 | 11-JUN-17:10 | 162130.67 | 13-JUN-15:20 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Fans:Electricity | 113.16 | 0.00 | 01-JAN-00:10 | 15154.29 | 12-JUN-15:20 |
General:Fans:Electricity | 113.16 | 0.00 | 01-JAN-00:10 | 15154.29 | 12-JUN-15:20 |
ExteriorLights:Electricity | 48.50 | 0.00 | 01-JAN-06:20 | 5557.43 | 01-JAN-06:10 |
General:ExteriorLights:Electricity | 48.50 | 0.00 | 01-JAN-06:20 | 5557.43 | 01-JAN-06:10 |
Cooling:Electricity | 867.98 | 0.00 | 01-JAN-00:10 | 86862.83 | 13-JUN-15:20 |
General:Cooling:Electricity | 867.98 | 0.00 | 01-JAN-00:10 | 86862.83 | 13-JUN-15:20 |
HeatRecovery:Electricity | 17.29 | 0.00 | 01-JAN-00:10 | 907.56 | 01-JAN-06:40 |
General:HeatRecovery:Electricity | 17.29 | 0.00 | 01-JAN-00:10 | 907.56 | 01-JAN-06:40 |
Electricity:Plant | 0.02 | 0.00 | 01-JAN-00:10 | 0.73 | 01-JAN-06:10 |
Pumps:Electricity | 0.02 | 0.00 | 01-JAN-00:10 | 0.73 | 01-JAN-06:10 |
General:Pumps:Electricity | 0.02 | 0.00 | 01-JAN-00:10 | 0.73 | 01-JAN-06:10 |
WIRED_LTG_ELECTRICITY | 5.68 | 0.00 | 01-JAN-00:10 | 560.65 | 18-DEC-17:10 |
WIRED_INT_EQUIP | 585.33 | 9277.75 | 01-JAN-00:10 | 34574.08 | 02-JAN-08:10 |
Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
NaturalGas:Facility | 85.86 | 1156.00 | 01-JAN-00:10 | 8617.92 | 05-JAN-12:10 |
NaturalGas:HVAC | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Heating:NaturalGas | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:NaturalGas | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
NaturalGas:Plant | 85.86 | 1156.00 | 01-JAN-00:10 | 8617.92 | 05-JAN-12:10 |
WaterSystems:NaturalGas | 85.86 | 1156.00 | 01-JAN-00:10 | 8617.92 | 05-JAN-12:10 |
Water Heater:WaterSystems:NaturalGas | 85.86 | 1156.00 | 01-JAN-00:10 | 8617.92 | 05-JAN-12:10 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
Water:Plant | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
WaterSystems:Water | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
WaterUse:WaterSystems:Water | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
MainsWater:Facility | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
MainsWater:Plant | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
WaterSystems:MainsWater | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
WaterUse:WaterSystems:MainsWater | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
Water Heater:WaterSystems:Water | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:MainsWater | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
EnergyTransfer:Facility | 5600.47 | 0.00 | 01-JAN-00:10 | 481392.24 | 13-JUN-15:30 |
EnergyTransfer:Building | 1870.34 | 0.00 | 01-JAN-00:10 | 163012.60 | 21-FEB-14:50 |
EnergyTransfer:Zone:CORE_BOTTOM | 325.77 | 0.00 | 01-JAN-00:10 | 28134.30 | 02-JAN-09:00 |
Heating:EnergyTransfer | 0.56 | 0.00 | 01-JAN-00:10 | 2237.52 | 15-DEC-06:10 |
Heating:EnergyTransfer:Zone:CORE_BOTTOM | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer | 0.56 | 0.00 | 01-JAN-00:10 | 2237.52 | 15-DEC-06:10 |
General:Heating:EnergyTransfer:Zone:CORE_BOTTOM | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer | 1869.78 | 0.00 | 01-JAN-00:10 | 163012.60 | 21-FEB-14:50 |
Cooling:EnergyTransfer:Zone:CORE_BOTTOM | 325.77 | 0.00 | 01-JAN-00:10 | 28134.30 | 02-JAN-09:00 |
General:Cooling:EnergyTransfer | 1869.78 | 0.00 | 01-JAN-00:10 | 163012.60 | 21-FEB-14:50 |
General:Cooling:EnergyTransfer:Zone:CORE_BOTTOM | 325.77 | 0.00 | 01-JAN-00:10 | 28134.30 | 02-JAN-09:00 |
EnergyTransfer:Zone:TOPFLOOR_PLENUM | 84.93 | 0.00 | 01-JAN-00:10 | 11441.34 | 05-MAY-13:10 |
Heating:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 0.19 | 0.00 | 01-JAN-00:10 | 1881.84 | 23-JAN-06:10 |
General:Heating:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 0.19 | 0.00 | 01-JAN-00:10 | 1881.84 | 23-JAN-06:10 |
Cooling:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 84.75 | 0.00 | 01-JAN-00:10 | 11441.34 | 05-MAY-13:10 |
General:Cooling:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 84.75 | 0.00 | 01-JAN-00:10 | 11441.34 | 05-MAY-13:10 |
EnergyTransfer:Zone:MIDFLOOR_PLENUM | 44.67 | 0.00 | 01-JAN-00:10 | 4710.37 | 12-JUN-16:00 |
Heating:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 0.12 | 0.00 | 01-JAN-00:10 | 628.67 | 17-DEC-10:40 |
General:Heating:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 0.12 | 0.00 | 01-JAN-00:10 | 628.67 | 17-DEC-10:40 |
Cooling:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 44.55 | 0.00 | 01-JAN-00:10 | 4710.37 | 12-JUN-16:00 |
General:Cooling:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 44.55 | 0.00 | 01-JAN-00:10 | 4710.37 | 12-JUN-16:00 |
EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 51.37 | 0.00 | 01-JAN-00:10 | 5014.16 | 30-MAY-12:20 |
Heating:EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 0.26 | 0.00 | 01-JAN-00:10 | 934.61 | 02-AUG-04:10 |
General:Heating:EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 0.26 | 0.00 | 01-JAN-00:10 | 934.61 | 02-AUG-04:10 |
Cooling:EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 51.11 | 0.00 | 01-JAN-00:10 | 5014.16 | 30-MAY-12:20 |
General:Cooling:EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 51.11 | 0.00 | 01-JAN-00:10 | 5014.16 | 30-MAY-12:20 |
EnergyTransfer:Zone:CORE_MID | 237.67 | 0.00 | 01-JAN-00:10 | 19203.94 | 02-JAN-08:30 |
Heating:EnergyTransfer:Zone:CORE_MID | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer:Zone:CORE_MID | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:CORE_MID | 237.67 | 0.00 | 01-JAN-00:10 | 19203.94 | 02-JAN-08:30 |
General:Cooling:EnergyTransfer:Zone:CORE_MID | 237.67 | 0.00 | 01-JAN-00:10 | 19203.94 | 02-JAN-08:30 |
EnergyTransfer:Zone:CORE_TOP | 257.66 | 0.00 | 01-JAN-00:10 | 21006.33 | 21-FEB-14:40 |
Heating:EnergyTransfer:Zone:CORE_TOP | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer:Zone:CORE_TOP | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:CORE_TOP | 257.66 | 0.00 | 01-JAN-00:10 | 21006.33 | 21-FEB-14:40 |
General:Cooling:EnergyTransfer:Zone:CORE_TOP | 257.66 | 0.00 | 01-JAN-00:10 | 21006.33 | 21-FEB-14:40 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 80.63 | 0.00 | 01-JAN-00:10 | 9121.80 | 12-JUN-15:00 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 80.63 | 0.00 | 01-JAN-00:10 | 9121.80 | 12-JUN-15:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 80.63 | 0.00 | 01-JAN-00:10 | 9121.80 | 12-JUN-15:00 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 62.33 | 0.00 | 01-JAN-00:10 | 7178.30 | 20-MAR-09:40 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 62.33 | 0.00 | 01-JAN-00:10 | 7178.30 | 20-MAR-09:40 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 62.33 | 0.00 | 01-JAN-00:10 | 7178.30 | 20-MAR-09:40 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 88.32 | 0.00 | 01-JAN-00:10 | 9819.71 | 26-DEC-13:20 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 88.32 | 0.00 | 01-JAN-00:10 | 9819.71 | 26-DEC-13:20 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 88.32 | 0.00 | 01-JAN-00:10 | 9819.71 | 26-DEC-13:20 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 62.52 | 0.00 | 01-JAN-00:10 | 7905.00 | 11-APR-15:40 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 62.52 | 0.00 | 01-JAN-00:10 | 7905.00 | 11-APR-15:40 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 62.52 | 0.00 | 01-JAN-00:10 | 7905.00 | 11-APR-15:40 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 79.75 | 0.00 | 01-JAN-00:10 | 8096.52 | 12-JUN-15:20 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 79.75 | 0.00 | 01-JAN-00:10 | 8096.52 | 12-JUN-15:20 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 79.75 | 0.00 | 01-JAN-00:10 | 8096.52 | 12-JUN-15:20 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 61.51 | 0.00 | 01-JAN-00:10 | 6584.80 | 20-MAR-09:40 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 61.51 | 0.00 | 01-JAN-00:10 | 6584.80 | 20-MAR-09:40 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 61.51 | 0.00 | 01-JAN-00:10 | 6584.80 | 20-MAR-09:40 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 104.12 | 0.00 | 01-JAN-00:10 | 10676.37 | 05-MAY-12:00 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 104.12 | 0.00 | 01-JAN-00:10 | 10676.37 | 05-MAY-12:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 104.12 | 0.00 | 01-JAN-00:10 | 10676.37 | 05-MAY-12:00 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 60.69 | 0.00 | 01-JAN-00:10 | 6889.07 | 12-JUN-16:00 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 60.69 | 0.00 | 01-JAN-00:10 | 6889.07 | 12-JUN-16:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 60.69 | 0.00 | 01-JAN-00:10 | 6889.07 | 12-JUN-16:00 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 74.03 | 0.00 | 01-JAN-00:10 | 7977.10 | 12-JUN-15:10 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 74.03 | 0.00 | 01-JAN-00:10 | 7977.10 | 12-JUN-15:10 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 74.03 | 0.00 | 01-JAN-00:10 | 7977.10 | 12-JUN-15:10 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 56.50 | 0.00 | 01-JAN-00:10 | 6651.59 | 05-MAY-09:00 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 56.50 | 0.00 | 01-JAN-00:10 | 6651.59 | 05-MAY-09:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 56.50 | 0.00 | 01-JAN-00:10 | 6651.59 | 05-MAY-09:00 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 81.01 | 0.00 | 01-JAN-00:10 | 8422.98 | 26-DEC-13:20 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 81.01 | 0.00 | 01-JAN-00:10 | 8422.98 | 26-DEC-13:20 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 81.01 | 0.00 | 01-JAN-00:10 | 8422.98 | 26-DEC-13:20 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 56.88 | 0.00 | 01-JAN-00:10 | 7099.91 | 18-APR-15:30 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 56.88 | 0.00 | 01-JAN-00:10 | 7099.91 | 18-APR-15:30 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 56.88 | 0.00 | 01-JAN-00:10 | 7099.91 | 18-APR-15:30 |
PlantLoopHeatingDemand:Facility | 31.77 | 0.00 | 01-JAN-00:10 | 3781.90 | 06-JAN-12:10 |
PlantLoopHeatingDemand:Plant | 31.77 | 0.00 | 01-JAN-00:10 | 3781.90 | 06-JAN-12:10 |
WaterSystems:PlantLoopHeatingDemand | 31.77 | 0.00 | 01-JAN-00:10 | 3781.90 | 06-JAN-12:10 |
General:WaterSystems:PlantLoopHeatingDemand | 31.77 | 0.00 | 01-JAN-00:10 | 3781.90 | 06-JAN-12:10 |
EnergyTransfer:HVAC | 3698.36 | 0.00 | 01-JAN-00:10 | 319811.37 | 15-JUN-10:00 |
HeatingCoils:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
CoolingCoils:EnergyTransfer | 3410.94 | 0.00 | 01-JAN-00:10 | 291826.62 | 13-JUN-15:30 |
HeatRecoveryForHeating:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 19-SEP-16:50 |
HeatRecoveryForCooling:EnergyTransfer | 287.42 | 0.00 | 01-JAN-00:10 | 34357.01 | 30-SEP-11:00 |
EnergyTransfer:Plant | 31.77 | 0.00 | 01-JAN-00:10 | 3781.90 | 06-JAN-12:10 |
WaterSystems:EnergyTransfer | 31.77 | 0.00 | 01-JAN-00:10 | 3781.90 | 06-JAN-12:10 |
WaterUse:WaterSystems:EnergyTransfer | 31.77 | 0.00 | 01-JAN-00:10 | 3781.90 | 06-JAN-12:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
CORE_BOTTOM | 0.000 | 0.000 | 0.000 | -325.772 | 0.000 | 0.000 | 32.689 | 48.333 | 236.167 | 0.000 | 0.000 | 0.000 | 8.583 | 0.000 | 0.000 | 0.000 | 0.000 | -0.001 |
CORE_MID | 0.000 | 0.000 | 0.000 | -237.672 | 0.000 | 0.000 | 32.764 | 48.333 | 115.425 | 0.000 | 0.000 | 0.000 | 41.150 | 0.000 | 0.000 | 0.000 | 0.000 | -0.001 |
CORE_TOP | 0.000 | 0.000 | 0.000 | -257.663 | 0.000 | 0.000 | 32.785 | 48.333 | 115.425 | 0.000 | 0.000 | 0.000 | 61.120 | 0.000 | 0.000 | 0.000 | 0.000 | -0.002 |
PERIMETER_TOP_ZN_3 | 0.000 | 0.000 | 0.000 | -80.626 | 0.000 | 0.000 | 6.891 | 5.834 | 24.333 | 35.713 | 0.000 | 0.256 | 10.856 | 0.000 | -3.217 | 0.000 | -0.040 | -0.001 |
PERIMETER_TOP_ZN_2 | 0.000 | 0.000 | 0.000 | -62.325 | 0.000 | 0.000 | 4.360 | 3.712 | 15.404 | 35.591 | 0.000 | 0.168 | 5.192 | 0.000 | -2.074 | 0.000 | -0.028 | -0.000 |
PERIMETER_TOP_ZN_1 | 0.000 | 0.000 | 0.000 | -88.321 | 0.000 | 0.000 | 6.882 | 5.811 | 24.332 | 45.887 | 0.000 | 0.253 | 8.408 | 0.000 | -3.209 | 0.000 | -0.043 | -0.000 |
PERIMETER_TOP_ZN_4 | 0.000 | 0.000 | 0.000 | -62.516 | 0.000 | 0.000 | 4.372 | 3.677 | 15.403 | 35.706 | 0.000 | 0.169 | 5.460 | 0.000 | -2.244 | 0.000 | -0.029 | -0.000 |
PERIMETER_BOT_ZN_3 | 0.000 | 0.000 | 0.000 | -79.746 | 0.000 | 0.000 | 6.887 | 5.823 | 24.333 | 35.936 | 0.000 | 0.141 | 10.129 | 0.000 | -3.480 | 0.000 | -0.023 | -0.000 |
PERIMETER_BOT_ZN_2 | 0.000 | 0.000 | 0.000 | -61.508 | 0.000 | 0.000 | 4.356 | 3.705 | 15.404 | 35.716 | 0.000 | 0.090 | 4.639 | 0.000 | -2.384 | 0.000 | -0.017 | -0.000 |
PERIMETER_BOT_ZN_1 | 0.000 | 0.000 | 0.000 | -104.112 | 0.000 | 0.000 | 6.748 | 5.803 | 24.332 | 45.702 | 0.000 | 20.782 | 4.774 | 0.000 | -3.701 | 0.000 | -0.328 | -0.000 |
PERIMETER_BOT_ZN_4 | 0.000 | 0.000 | 0.000 | -60.686 | 0.000 | 0.000 | 4.357 | 3.671 | 15.403 | 35.769 | 0.000 | 0.089 | 4.009 | 0.000 | -2.594 | 0.000 | -0.018 | -0.000 |
PERIMETER_MID_ZN_3 | 0.000 | 0.000 | 0.000 | -74.027 | 0.000 | 0.000 | 6.888 | 5.834 | 24.333 | 36.087 | 0.000 | 0.219 | 4.011 | 0.000 | -3.310 | 0.000 | -0.035 | -0.000 |
PERIMETER_MID_ZN_2 | 0.000 | 0.000 | 0.000 | -56.501 | 0.000 | 0.000 | 3.214 | 3.712 | 15.404 | 35.864 | 0.000 | 0.143 | 0.319 | 0.000 | -2.131 | 0.000 | -0.024 | -0.000 |
PERIMETER_MID_ZN_1 | 0.000 | 0.000 | 0.000 | -81.004 | 0.000 | 0.000 | 6.871 | 5.811 | 24.332 | 46.260 | 0.000 | 0.215 | 0.850 | 0.000 | -3.298 | 0.000 | -0.038 | -0.000 |
PERIMETER_MID_ZN_4 | 0.000 | 0.000 | 0.000 | -56.874 | 0.000 | 0.000 | 4.363 | 3.677 | 15.403 | 35.918 | 0.000 | 0.141 | 0.000 | 0.000 | -2.330 | 0.000 | -0.025 | -0.274 |
TOPFLOOR_PLENUM | 0.189 | -84.745 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.312 | 84.288 | 0.000 | 0.000 | 0.000 | -0.043 | 0.000 |
MIDFLOOR_PLENUM | 0.116 | -44.553 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.335 | 44.154 | 0.000 | 0.000 | 0.000 | -0.052 | 0.000 |
FIRSTFLOOR_PLENUM | 0.256 | -51.110 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.258 | 50.637 | 0.000 | 0.000 | 0.000 | -0.042 | -0.000 |
Total Facility | 0.561 | -180.408 | 0.000 | -1689.354 | 0.000 | 0.000 | 164.428 | 202.069 | 705.434 | 460.148 | 0.000 | 23.573 | 348.580 | 0.000 | -33.971 | 0.000 | -0.785 | -0.281 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
CORE_BOTTOM | 27-NOV-05:02 | 0.00 | 0.00 | 0.00 | -41734.10 | 0.00 | 0.00 | 0.00 | 468.92 | 4405.64 | 0.00 | 0.00 | 0.00 | 36859.54 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 02-JAN-05:04 | 0.00 | 0.00 | 0.00 | -33007.44 | 0.00 | 0.00 | 0.00 | 468.92 | 2442.06 | 0.00 | 0.00 | 0.00 | 30096.47 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 23-OCT-04:02 | 0.00 | 0.00 | 0.00 | -33357.82 | 0.00 | 0.00 | 0.00 | 468.92 | 2442.06 | 0.00 | 0.00 | 0.00 | 30446.85 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 11-JUN-12:32 | 0.00 | 0.00 | 0.00 | -12167.94 | 0.00 | 0.00 | 25.35 | 23.57 | 478.42 | 4321.82 | 0.00 | 70.04 | 7248.74 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 14-MAY-09:02 | 0.00 | 0.00 | 0.00 | -10813.01 | 0.00 | 0.00 | 16.01 | 14.92 | 302.86 | 4986.49 | 0.00 | 14.36 | 5478.37 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 25-DEC-15:32 | 0.00 | 0.00 | 0.00 | -12405.53 | 0.00 | 0.00 | 23.91 | 23.57 | 478.41 | 5000.73 | 0.00 | 12.20 | 6866.70 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 25-DEC-15:32 | 0.00 | 0.00 | 0.00 | -12749.06 | 0.00 | 0.00 | 14.92 | 14.92 | 302.86 | 5415.22 | 0.00 | 9.73 | 6991.40 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 11-JUN-12:32 | 0.00 | 0.00 | 0.00 | -10084.28 | 0.00 | 0.00 | 27.17 | 23.57 | 478.42 | 4432.24 | 0.00 | 39.96 | 5082.93 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 20-FEB-09:53 | 0.00 | 0.00 | 0.00 | -9578.55 | 0.00 | 0.00 | 16.55 | 14.92 | 302.86 | 4618.07 | 0.00 | 5.68 | 4620.46 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 05-MAY-12:00 | 0.00 | 0.00 | 0.00 | -10675.76 | 0.00 | 0.00 | 280.63 | 424.37 | 1275.77 | 3124.52 | 0.00 | 10576.40 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -5005.92 |
PERIMETER_BOT_ZN_4 | 20-FEB-15:52 | 0.00 | 0.00 | 0.00 | -10549.92 | 0.00 | 0.00 | 15.62 | 14.92 | 302.86 | 5104.89 | 0.00 | 25.78 | 5085.86 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 11-JUN-12:32 | 0.00 | 0.00 | 0.00 | -10041.81 | 0.00 | 0.00 | 26.89 | 23.57 | 478.42 | 4409.12 | 0.00 | 61.33 | 5042.48 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 14-MAY-09:02 | 0.00 | 0.00 | 0.00 | -10152.98 | 0.00 | 0.00 | 16.43 | 14.92 | 302.86 | 5016.69 | 0.00 | 12.52 | 4789.56 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 31-DEC-12:52 | 0.00 | 0.00 | 0.00 | -10443.32 | 0.00 | 0.00 | 25.12 | 23.57 | 478.41 | 7339.38 | 0.00 | 22.01 | 2554.82 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 10-SEP-16:42 | 0.00 | 0.00 | 0.00 | -11153.45 | 0.00 | 0.00 | 16.03 | 14.92 | 302.86 | 3802.66 | 0.00 | 1.83 | 7015.15 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 05-MAY-13:10 | 0.00 | -11441.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.64 | 11405.72 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 30-MAY-06:03 | 0.00 | -4819.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4819.92 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 30-MAY-12:10 | 0.00 | -5342.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.34 | 5336.70 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 20-MAR-04:02 | 0.00 | 8649.04 | 0.00 | -193818.57 | 0.00 | 0.00 | 0.00 | 2375.34 | 14333.92 | 0.00 | 0.00 | 117.18 | 170105.38 | 0.00 | -1762.30 | 0.00 | 0.00 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
CORE_BOTTOM | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 23-JAN-06:03 | 5622.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -9.62 | -5612.43 |
MIDFLOOR_PLENUM | 18-AUG-05:03 | 2195.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.27 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -2195.66 |
FIRSTFLOOR_PLENUM | 02-AUG-04:03 | 3738.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.56 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -3758.94 |
Total Facility | 13-NOV-05:02 | -179743.80 | 188829.23 | 0.00 | -188829.23 | 0.00 | 0.00 | 0.00 | 2375.34 | 14333.92 | 0.00 | 0.00 | 0.00 | 167498.58 | 0.00 | -4427.17 | 0.00 | -36.87 | 0.00 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PACU_VAV_BOT | 4.9823 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 4.5844 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
PACU_VAV_MID | 4.2982 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 3.8385 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
PACU_VAV_TOP | 4.8320 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 4.6403 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PACU_VAV_BOT | 2.4912 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 1.3120 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
PACU_VAV_MID | 2.1491 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 1.2720 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
PACU_VAV_TOP | 2.4160 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 1.3539 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
CORE_BOTTOM | PACU_VAV_BOT | 0.000000 | 52.9387 | 0.000432 | 983.54 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
CORE_MID | PACU_VAV_MID | 0.000000 | 52.9387 | 0.000432 | 983.54 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
CORE_TOP | PACU_VAV_TOP | 0.000000 | 52.9387 | 0.000432 | 983.54 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP | 0.000000 | 7.0652 | 0.000432 | 131.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP | 0.000000 | 7.0647 | 0.000432 | 131.25 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT | 0.000000 | 7.0652 | 0.000432 | 131.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT | 0.000000 | 7.0647 | 0.000432 | 131.25 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_3 | PACU_VAV_MID | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_2 | PACU_VAV_MID | 0.000000 | 7.0652 | 0.000432 | 131.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_1 | PACU_VAV_MID | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_4 | PACU_VAV_MID | 0.000000 | 7.0647 | 0.000432 | 131.25 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PACU_VAV_BOT | 0.00 | 0.000432 | 1660.7286 | 0.0000 | 0.0000 | 0.0000 | |
PACU_VAV_MID | 0.00 | 0.000432 | 1660.7286 | 0.0000 | 0.0000 | 0.0000 | |
PACU_VAV_TOP | 0.00 | 0.000432 | 1660.7286 | 0.0000 | 0.0000 | 0.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
CORE_BOTTOM | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.7030 | 2.7030 | 0.7622 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_MID | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.9473 | 1.9473 | 0.7244 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_TOP | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.1436 | 2.1436 | 0.7653 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.6886 | 0.6886 | 0.1611 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.6146 | 0.6146 | 0.1229 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.6706 | 0.6706 | 0.1616 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7147 | 0.7147 | 0.1429 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.5775 | 0.5775 | 0.1611 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.5514 | 0.5514 | 0.1103 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.5617 | 0.5617 | 0.1606 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.5887 | 0.5887 | 0.1177 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_3 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.5770 | 0.5770 | 0.1523 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_2 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.5833 | 0.5833 | 0.1167 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_1 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.5618 | 0.5618 | 0.1528 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_4 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.6288 | 0.6288 | 0.1258 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PACU_VAV_BOT | 4.9823 | 4.5844 | 4.9823 | 1.3120 | 0.0000 | 1.0000 |
PACU_VAV_MID | 4.2982 | 3.8385 | 4.2982 | 1.2720 | 0.0000 | 1.0000 |
PACU_VAV_TOP | 4.8320 | 4.6403 | 4.8320 | 1.3539 | 0.0000 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
CORE_BOTTOM | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.3515 | 1.3515 | 0.7622 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_MID | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.9737 | 0.9737 | 0.7244 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_TOP | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.0718 | 1.0718 | 0.7653 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3443 | 0.3443 | 0.1611 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3073 | 0.3073 | 0.1229 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3353 | 0.3353 | 0.1616 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3573 | 0.3573 | 0.1429 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2888 | 0.2888 | 0.1611 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2757 | 0.2757 | 0.1103 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2808 | 0.2808 | 0.1606 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2944 | 0.2944 | 0.1177 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_3 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2885 | 0.2885 | 0.1523 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_2 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2916 | 0.2916 | 0.1167 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_1 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2809 | 0.2809 | 0.1528 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_4 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3144 | 0.3144 | 0.1258 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PACU_VAV_BOT | 2.4912 | 1.3120 | 1.3120 | 1.3120 | 0.0000 | 1.0000 |
PACU_VAV_MID | 2.1491 | 1.2720 | 1.2720 | 1.2720 | 0.0000 | 1.0000 |
PACU_VAV_TOP | 2.4160 | 1.3539 | 1.3539 | 1.3539 | 0.0000 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** Ho Chi Minh City-Tan Son Nhat Intl AP - VNM IWEC2 WMO#=489000 |
Total gross floor area [m2] | 4982.19 |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
CORE_BOTTOM | 983.54 | 983.54 | 0.00 | 113.98 |
CORE_MID | 983.54 | 983.54 | 0.00 | 113.98 |
CORE_TOP | 983.54 | 983.54 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_3 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_2 | 131.26 | 131.26 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_1 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_4 | 131.25 | 131.25 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_3 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_2 | 131.26 | 131.26 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_1 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_4 | 131.25 | 131.25 | 0.00 | 113.98 |
PERIMETER_MID_ZN_3 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_MID_ZN_2 | 131.26 | 131.26 | 0.00 | 96.54 |
PERIMETER_MID_ZN_1 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_MID_ZN_4 | 131.25 | 131.25 | 0.00 | 113.98 |
TOPFLOOR_PLENUM | 1660.73 | 1660.73 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 1660.73 | 1660.73 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 1660.73 | 1660.73 | 0.00 | 0.00 |
Totals | 4982.19 | 4982.19 | 0.00 |
Data | |
Number of hours heating loads not met | 0.00 |
Number of hours cooling loads not met | 838.00 |
Number of hours not met | 838.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- General | 867.98 | 86862.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 202.07 | 19951.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 48.50 | 5557.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 584.69 | 34487.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- ElevatorLift | 120.10 | 11290.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- ElevatorLightsFan | 0.64 | 86.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Transformer | 11.65 | 831.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 113.16 | 15154.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- General | 0.02 | 0.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- General | 17.29 | 907.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 0.00 | 0.00 | 85.86 | 8617.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 705.43 | 1966.10 |
Natural Gas | 0.00 | 85.86 |
Additional | 0.00 | 0.00 |
Total | 705.43 | 2051.96 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 40.56 |
Space Heating | 0.00 |
Space Cooling | 174.22 |
Fans (All) | 22.71 |
Service Water Heating | 0.00 |
Receptacle Equipment | 141.59 |
Miscellaneous (All) | 394.63 |
Subtotal | 394.63 |
Natural Gas [MJ/m2] | |
Space Heating | 0.00 |
Service Water Heating | 17.23 |
Miscellaneous (All) | 17.23 |
Subtotal | 17.23 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 9.85 |
Space Heating | 0.00 |
Space Cooling | 42.30 |
Fans (All) | 5.51 |
Service Water Heating | 4.18 |
Receptacle Equipment | 34.38 |
Miscellaneous | 3.78 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 4472. | 4472. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_C_2016 | 6752. | 8760. |
ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 6828. | 8760. |
ALWAYS_OFF | 0. | 0. |
LTG_SCH_OFFICE | 2362. | 8760. |
BLDG_EQUIP_SCH | 4095. | 8760. |
BLDG_OCC_SCH | 2528. | 5992. |
BLDG_OCC_SCH_W_SB | 1878. | 5056. |
BLDG_OCC_SCH_WO_SB | 2545. | 5992. |
BLDG_ELEVATORS | 2070. | 8760. |
ELEV_LIGHT_FAN_SCH_24_7 | 8760. | 8760. |
ELEV_LIGHT_FAN_SCH_ADD_DF | 1470. | 4212. |
BLDG_SWH_SCH | 1441. | 5992. |
WORK_EFF_SCH | 0. | 0. |
FAN_SCH | 8760. | 8760. |
REHEATCOILAVAILSCHED | 8760. | 8760. |
COOLINGCOILAVAILSCHED | 8760. | 8760. |
MINOA_MOTORIZEDDAMPER_SCHED | 4472. | 4472. |
MINOA_SCHED | 8760. | 8760. |
CORE_BOTTOM SUB CAT LATENT FRACT SCHED | 438. | 8760. |
CORE_BOTTOM SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
CORE_MID SUB CAT LATENT FRACT SCHED | 438. | 8760. |
CORE_MID SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
CORE_TOP SUB CAT LATENT FRACT SCHED | 438. | 8760. |
CORE_TOP SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_TOP_ZN_3 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_TOP_ZN_3 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_TOP_ZN_2 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_TOP_ZN_2 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_TOP_ZN_1 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_TOP_ZN_1 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_TOP_ZN_4 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_TOP_ZN_4 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_BOT_ZN_3 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_BOT_ZN_3 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_BOT_ZN_2 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_BOT_ZN_2 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_BOT_ZN_1 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_BOT_ZN_1 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_BOT_ZN_4 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_BOT_ZN_4 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_MID_ZN_3 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_MID_ZN_3 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_MID_ZN_2 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_MID_ZN_2 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_MID_ZN_1 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_MID_ZN_1 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_MID_ZN_4 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_MID_ZN_4 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
INFIL_SCH_PNNL | 5172. | 8760. |
INFIL_DOOR_OPENING_SCH | 1154. | 3380. |
PERIMETER_MID_ZN_2_OA_MULT | 7824. | 7824. |
PERIMETER_MID_ZN_2_MDP_SCH | 1574. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
HTGSETP_SCH_YES_OPTIMUM_STARTSTOP | CORE_BOTTOM DUAL SP CONTROL | January | 21.00 | 365 | 15.60 | 365 |
CLGSETP_SCH_YES_OPTIMUM_STARTSTOP | CORE_BOTTOM DUAL SP CONTROL | July | 24.00 | 365 | 26.70 | 365 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
Heat Index HoursSafe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
CORE_BOTTOM | 8474.83 | 285.17 | 0.00 | 0.00 | 0.00 |
CORE_MID | 8723.67 | 36.33 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 8698.00 | 62.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 8308.50 | 451.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 8170.50 | 589.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 8176.17 | 583.83 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 8027.00 | 733.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 8502.17 | 257.83 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 8152.83 | 607.17 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 8164.00 | 596.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 7859.17 | 900.83 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 8438.33 | 321.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 8263.00 | 497.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 8269.00 | 491.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 8061.33 | 698.67 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 8001.50 | 758.50 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 8743.17 | 16.83 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 8753.50 | 6.50 | 0.00 | 0.00 | 0.00 |
Min | 7859.17 | 6.50 | 0.00 | 0.00 | 0.00 |
Max | 8753.50 | 900.83 | 0.00 | 0.00 | 0.00 |
Average | 8321.48 | 438.52 | 0.00 | 0.00 | 0.00 |
Sum | 149786.67 | 7893.33 | 0.00 | 0.00 | 0.00 |
Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
CORE_BOTTOM | 128256.00 | 48.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 128299.67 | 4.33 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 128298.00 | 6.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 24499.00 | 410.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 10134.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 128299.67 | 410.00 | 0.00 | 0.00 | 0.00 |
Average | 34117.31 | 26.02 | 0.00 | 0.00 | 0.00 |
Sum | 614111.67 | 468.33 | 0.00 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
CORE_BOTTOM | 7255.33 | 1504.67 | 0.00 | 0.00 | 0.00 |
CORE_MID | 8660.33 | 99.67 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 8577.83 | 182.17 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 6167.83 | 2592.17 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 6037.67 | 2722.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 5960.33 | 2799.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 6131.67 | 2628.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 6697.33 | 2062.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 6099.67 | 2660.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 4259.50 | 4500.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 6052.00 | 2708.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 6582.50 | 2177.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 6407.50 | 2352.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 6376.67 | 2383.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 6384.33 | 2375.67 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 6580.00 | 2180.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 7953.50 | 806.50 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 8189.17 | 570.83 | 0.00 | 0.00 | 0.00 |
Min | 4259.50 | 99.67 | 0.00 | 0.00 | 0.00 |
Max | 8660.33 | 4500.50 | 0.00 | 0.00 | 0.00 |
Average | 6687.40 | 2072.60 | 0.00 | 0.00 | 0.00 |
Sum | 120373.17 | 37306.83 | 0.00 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
CORE_BOTTOM | 127879.33 | 424.67 | 0.00 | 0.00 | 0.00 |
CORE_MID | 128286.00 | 18.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 128275.33 | 28.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 24900.50 | 8.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 24900.50 | 8.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 24908.50 | 0.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 15084.33 | 9824.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 24904.83 | 4.17 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 10134.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 24904.50 | 4.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 128286.00 | 9824.67 | 0.00 | 0.00 | 0.00 |
Average | 33569.88 | 573.45 | 0.00 | 0.00 | 0.00 |
Sum | 604257.83 | 10322.17 | 0.00 | 0.00 | 0.00 |
SET ≤ 12.2°C Hours (°C) | SET ≤ 12.2°C OccupantHours (°C) | Longest SET ≤ 12.2°C Duration [hr] | Start Time of the Longest SET ≤ 12.2°C Duration | |
None |
SET > 30°C Hours (°C) | SET > 30°C OccupantHours (°C) | Longest SET > 30°C Duration [hr] | Start Time of the Longest SET > 30°C Duration | |
None |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
CO2 Level HoursSafe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:24
Illuminance Level HoursA Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
CORE_BOTTOM | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_3 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_2 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_1 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_4 | 0.00 | 0.00 | 8760.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 0.00 | 0.00 | 8760.00 | 0.00 |
Average | 0.00 | 0.00 | 5840.00 | 0.00 |
Sum | 0.00 | 0.00 | 105120.00 | 0.00 |
A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
CORE_BOTTOM | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 0.00 | 0.00 | 14016.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 0.00 | 0.00 | 14016.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 0.00 | 0.00 | 14016.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 0.00 | 0.00 | 14016.00 | 0.00 |
PERIMETER_MID_ZN_3 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_MID_ZN_2 | 0.00 | 0.00 | 10134.00 | 0.00 |
PERIMETER_MID_ZN_1 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_MID_ZN_4 | 0.00 | 0.00 | 14016.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 0.00 | 0.00 | 24909.00 | 0.00 |
Average | 0.00 | 0.00 | 12759.33 | 0.00 |
Sum | 0.00 | 0.00 | 229668.00 | 0.00 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Environment
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 26.415 |
February | 27.500 |
March | 28.331 |
April | 29.151 |
May | 29.006 |
June | 28.856 |
July | 27.250 |
August | 27.543 |
September | 27.578 |
October | 26.894 |
November | 26.683 |
December | 25.974 |
Annual Sum or Average | 27.594 |
Minimum of Months | 25.974 |
Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Environment
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 26.415 |
February | 27.500 |
March | 28.331 |
April | 29.151 |
May | 29.006 |
June | 28.856 |
July | 27.250 |
August | 27.543 |
September | 27.578 |
October | 26.894 |
November | 26.683 |
December | 25.974 |
Annual Sum or Average | 27.594 |
Minimum of Months | 25.974 |
Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2021
For: Environment
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 26.415 |
February | 27.500 |
March | 28.331 |
April | 29.151 |
May | 29.006 |
June | 28.856 |
July | 27.250 |
August | 27.543 |
September | 27.578 |
October | 26.894 |
November | 26.683 |
December | 25.974 |
Annual Sum or Average | 27.594 |
Minimum of Months | 25.974 |
Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Environment
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 26.415 |
February | 27.500 |
March | 28.331 |
April | 29.151 |
May | 29.006 |
June | 28.856 |
July | 27.250 |
August | 27.543 |
September | 27.578 |
October | 26.894 |
November | 26.683 |
December | 25.974 |
Annual Sum or Average | 27.594 |
Minimum of Months | 25.974 |
Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME OFFICEMEDIUM
For: Environment
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 26.415 |
February | 27.500 |
March | 28.331 |
April | 29.151 |
May | 29.006 |
June | 28.856 |
July | 27.250 |
August | 27.543 |
September | 27.578 |
October | 26.894 |
November | 26.683 |
December | 25.974 |
Annual Sum or Average | 27.594 |
Minimum of Months | 25.974 |
Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Environment
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 26.415 |
February | 27.500 |
March | 28.331 |
April | 29.151 |
May | 29.006 |
June | 28.856 |
July | 27.250 |
August | 27.543 |
September | 27.578 |
October | 26.894 |
November | 26.683 |
December | 25.974 |
Annual Sum or Average | 27.594 |
Minimum of Months | 25.974 |
Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Environment
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 26.415 |
February | 27.500 |
March | 28.331 |
April | 29.151 |
May | 29.006 |
June | 28.856 |
July | 27.250 |
August | 27.543 |
September | 27.578 |
October | 26.894 |
November | 26.683 |
December | 25.974 |
Annual Sum or Average | 27.594 |
Minimum of Months | 25.974 |
Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 0A
For: Environment
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 26.415 |
February | 27.500 |
March | 28.331 |
April | 29.151 |
May | 29.006 |
June | 28.856 |
July | 27.250 |
August | 27.543 |
September | 27.578 |
October | 26.894 |
November | 26.683 |
December | 25.974 |
Annual Sum or Average | 27.594 |
Minimum of Months | 25.974 |
Maximum of Months | 29.151 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY VNM_HOCHIMINH_TANSONHOA
For: Environment
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 26.415 |
February | 27.500 |
March | 28.331 |
April | 29.151 |
May | 29.006 |
June | 28.856 |
July | 27.250 |
August | 27.543 |
September | 27.578 |
October | 26.894 |
November | 26.683 |
December | 25.974 |
Annual Sum or Average | 27.594 |
Minimum of Months | 25.974 |
Maximum of Months | 29.151 |
Report: ZoneCoolingSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.275551E+11 | 41161.81 | 23-JAN-05:03 | 18.95 | 17.06 | 0.199314E+10 | 2606.54 | 02-JAN-14:30 | 18.95 | 17.06 |
February | 0.249694E+11 | 40778.87 | 24-FEB-05:03 | 23.00 | 19.45 | 0.180727E+10 | 2606.54 | 21-FEB-10:20 | 23.00 | 19.45 |
March | 0.288003E+11 | 40620.36 | 07-MAR-05:03 | 24.00 | 22.62 | 0.215798E+10 | 2606.54 | 03-MAR-10:20 | 24.00 | 22.62 |
April | 0.266791E+11 | 40042.37 | 05-APR-04:03 | 26.08 | 23.61 | 0.191576E+10 | 2606.55 | 20-APR-13:20 | 33.70 | 26.45 |
May | 0.285901E+11 | 40123.28 | 11-MAY-04:03 | 24.17 | 23.96 | 0.207529E+10 | 2606.54 | 25-MAY-13:30 | 30.30 | 27.68 |
June | 0.283482E+11 | 40255.77 | 21-JUN-04:03 | 23.33 | 23.13 | 0.206910E+10 | 2606.55 | 16-JUN-13:00 | 23.33 | 23.13 |
July | 0.268228E+11 | 40519.33 | 18-JUL-04:03 | 23.87 | 23.23 | 0.192298E+10 | 2606.54 | 03-JUL-13:30 | 23.87 | 23.23 |
August | 0.283266E+11 | 40969.10 | 22-AUG-04:03 | 24.08 | 23.67 | 0.215882E+10 | 2606.55 | 03-AUG-13:00 | 24.08 | 23.67 |
September | 0.262199E+11 | 40451.66 | 19-SEP-04:03 | 23.08 | 22.98 | 0.191590E+10 | 2606.54 | 14-SEP-13:30 | 23.08 | 22.98 |
October | 0.267882E+11 | 41067.90 | 23-OCT-04:02 | 22.58 | 22.48 | 0.199315E+10 | 2606.54 | 30-OCT-13:30 | 24.25 | 24.19 |
November | 0.264308E+11 | 41734.95 | 27-NOV-05:02 | 22.00 | 20.87 | 0.197353E+10 | 2606.54 | 08-NOV-14:30 | 22.00 | 20.87 |
December | 0.262413E+11 | 41018.99 | 27-DEC-05:03 | 19.00 | 18.34 | 0.192241E+10 | 2606.54 | 11-DEC-14:30 | 19.00 | 18.34 |
Annual Sum or Average | 0.325772E+12 | 0.239053E+11 | ||||||||
Minimum of Months | 0.249694E+11 | 40042.37 | 18.95 | 17.06 | 0.180727E+10 | 2606.54 | 18.95 | 17.06 | ||
Maximum of Months | 0.288003E+11 | 41734.95 | 26.08 | 23.96 | 0.215882E+10 | 2606.55 | 33.70 | 27.68 |
Report: ZoneCoolingSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.678157E+10 | 10040.70 | 31-JAN-14:40 | 32.33 | 22.35 | 0.00 | 0.00 | 01-JAN-00:10 | 32.33 | 22.35 |
February | 0.679697E+10 | 11256.59 | 21-FEB-14:30 | 34.50 | 21.90 | 0.00 | 0.00 | 01-FEB-00:10 | 34.50 | 21.90 |
March | 0.828348E+10 | 11429.71 | 20-MAR-13:50 | 35.03 | 23.24 | 0.00 | 0.00 | 01-MAR-00:10 | 35.03 | 23.24 |
April | 0.799378E+10 | 10686.63 | 11-APR-14:00 | 34.90 | 26.25 | 0.00 | 0.00 | 01-APR-00:10 | 34.90 | 26.25 |
May | 0.793170E+10 | 11441.34 | 05-MAY-13:10 | 36.33 | 27.23 | 0.00 | 0.00 | 01-MAY-00:10 | 36.33 | 27.23 |
June | 0.833111E+10 | 11150.65 | 16-JUN-14:00 | 36.00 | 27.59 | 0.00 | 0.00 | 01-JUN-00:10 | 36.00 | 27.59 |
July | 0.677200E+10 | 9789.86 | 14-JUL-14:20 | 32.17 | 24.82 | 0.00 | 0.00 | 01-JUL-00:10 | 32.17 | 24.82 |
August | 0.684044E+10 | 10468.75 | 14-AUG-13:40 | 33.27 | 27.64 | 0.00 | 0.00 | 01-AUG-00:10 | 33.27 | 27.64 |
September | 0.660621E+10 | 10364.43 | 06-SEP-14:00 | 34.00 | 26.51 | 0.00 | 0.00 | 01-SEP-00:10 | 34.00 | 26.51 |
October | 0.599831E+10 | 9817.99 | 02-OCT-13:10 | 31.20 | 26.20 | 0.00 | 0.00 | 01-OCT-00:10 | 31.20 | 26.20 |
November | 0.619115E+10 | 9635.98 | 22-NOV-13:02 | 31.50 | 24.57 | 0.00 | 0.00 | 01-NOV-00:10 | 31.50 | 24.57 |
December | 0.621946E+10 | 9930.78 | 26-DEC-13:02 | 32.00 | 23.12 | 0.00 | 0.00 | 01-DEC-00:10 | 32.00 | 23.12 |
Annual Sum or Average | 0.847462E+11 | 0.00 | ||||||||
Minimum of Months | 0.599831E+10 | 9635.98 | 31.20 | 21.90 | 0.00 | 0.00 | 31.20 | 21.90 | ||
Maximum of Months | 0.833111E+10 | 11441.34 | 36.33 | 27.64 | 0.00 | 0.00 | 36.33 | 27.64 |
Report: ZoneCoolingSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.367544E+10 | 4771.39 | 02-JAN-07:03 | 23.85 | 23.26 | 0.00 | 0.00 | 01-JAN-00:10 | 23.85 | 23.26 |
February | 0.349797E+10 | 4699.60 | 21-FEB-16:10 | 31.80 | 23.94 | 0.00 | 0.00 | 01-FEB-00:10 | 31.80 | 23.94 |
March | 0.409506E+10 | 4531.70 | 20-MAR-15:20 | 34.77 | 24.85 | 0.00 | 0.00 | 01-MAR-00:10 | 34.77 | 24.85 |
April | 0.390030E+10 | 4214.60 | 17-APR-15:30 | 33.05 | 26.46 | 0.00 | 0.00 | 01-APR-00:10 | 33.05 | 26.46 |
May | 0.415670E+10 | 4819.98 | 30-MAY-06:03 | 27.38 | 27.16 | 0.00 | 0.00 | 01-MAY-00:10 | 27.38 | 27.16 |
June | 0.430430E+10 | 4710.37 | 12-JUN-16:00 | 35.40 | 27.71 | 0.00 | 0.00 | 01-JUN-00:10 | 35.40 | 27.71 |
July | 0.361452E+10 | 4317.42 | 31-JUL-06:03 | 24.50 | 23.34 | 0.00 | 0.00 | 01-JUL-00:10 | 24.50 | 23.34 |
August | 0.368500E+10 | 4274.40 | 14-AUG-06:03 | 26.22 | 26.00 | 0.00 | 0.00 | 01-AUG-00:10 | 26.22 | 26.00 |
September | 0.346407E+10 | 4781.42 | 05-SEP-06:03 | 26.10 | 25.95 | 0.00 | 0.00 | 01-SEP-00:10 | 26.10 | 25.95 |
October | 0.341974E+10 | 4593.70 | 10-OCT-06:03 | 23.95 | 23.25 | 0.00 | 0.00 | 01-OCT-00:10 | 23.95 | 23.25 |
November | 0.344374E+10 | 4441.95 | 13-NOV-13:02 | 31.92 | 25.57 | 0.00 | 0.00 | 01-NOV-00:10 | 31.92 | 25.57 |
December | 0.329688E+10 | 4407.24 | 26-DEC-07:03 | 23.17 | 21.69 | 0.00 | 0.00 | 01-DEC-00:10 | 23.17 | 21.69 |
Annual Sum or Average | 0.445537E+11 | 0.00 | ||||||||
Minimum of Months | 0.329688E+10 | 4214.60 | 23.17 | 21.69 | 0.00 | 0.00 | 23.17 | 21.69 | ||
Maximum of Months | 0.430430E+10 | 4819.98 | 35.40 | 27.71 | 0.00 | 0.00 | 35.40 | 27.71 |
Report: ZoneCoolingSummaryMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.425096E+10 | 5035.06 | 02-JAN-07:03 | 23.85 | 23.26 | 0.00 | 0.00 | 01-JAN-00:10 | 23.85 | 23.26 |
February | 0.396683E+10 | 4970.65 | 21-FEB-16:10 | 31.80 | 23.94 | 0.00 | 0.00 | 01-FEB-00:10 | 31.80 | 23.94 |
March | 0.460048E+10 | 4743.20 | 20-MAR-12:10 | 34.20 | 23.37 | 0.00 | 0.00 | 01-MAR-00:10 | 34.20 | 23.37 |
April | 0.434464E+10 | 4598.23 | 17-APR-15:50 | 32.75 | 26.32 | 0.00 | 0.00 | 01-APR-00:10 | 32.75 | 26.32 |
May | 0.467030E+10 | 5342.44 | 30-MAY-12:10 | 33.10 | 27.55 | 0.00 | 0.00 | 01-MAY-00:10 | 33.10 | 27.55 |
June | 0.485477E+10 | 5123.48 | 12-JUN-12:09 | 34.05 | 27.94 | 0.00 | 0.00 | 01-JUN-00:10 | 34.05 | 27.94 |
July | 0.420660E+10 | 4713.15 | 17-JUL-12:10 | 30.80 | 25.66 | 0.00 | 0.00 | 01-JUL-00:10 | 30.80 | 25.66 |
August | 0.432625E+10 | 4786.87 | 14-AUG-12:08 | 33.13 | 27.67 | 0.00 | 0.00 | 01-AUG-00:10 | 33.13 | 27.67 |
September | 0.399862E+10 | 4954.43 | 05-SEP-12:10 | 33.02 | 26.93 | 0.00 | 0.00 | 01-SEP-00:10 | 33.02 | 26.93 |
October | 0.397944E+10 | 4822.67 | 10-OCT-06:03 | 23.95 | 23.25 | 0.00 | 0.00 | 01-OCT-00:10 | 23.95 | 23.25 |
November | 0.401965E+10 | 4909.34 | 13-NOV-13:10 | 31.92 | 25.57 | 0.00 | 0.00 | 01-NOV-00:10 | 31.92 | 25.57 |
December | 0.389185E+10 | 4841.42 | 26-DEC-07:03 | 23.17 | 21.69 | 0.00 | 0.00 | 01-DEC-00:10 | 23.17 | 21.69 |
Annual Sum or Average | 0.511104E+11 | 0.00 | ||||||||
Minimum of Months | 0.389185E+10 | 4598.23 | 23.17 | 21.69 | 0.00 | 0.00 | 23.17 | 21.69 | ||
Maximum of Months | 0.485477E+10 | 5342.44 | 34.20 | 27.94 | 0.00 | 0.00 | 34.20 | 27.94 |
Report: ZoneCoolingSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.198429E+11 | 33009.14 | 02-JAN-05:04 | 23.28 | 23.04 | 0.198661E+10 | 2606.55 | 24-JAN-10:09 | 20.83 | 18.11 |
February | 0.182401E+11 | 29449.27 | 22-FEB-05:03 | 24.00 | 22.62 | 0.180183E+10 | 2606.54 | 24-FEB-10:09 | 28.50 | 22.00 |
March | 0.210761E+11 | 28926.30 | 21-MAR-04:03 | 25.58 | 22.99 | 0.215214E+10 | 2606.54 | 03-MAR-10:09 | 25.58 | 22.99 |
April | 0.199026E+11 | 28770.64 | 04-APR-04:03 | 25.97 | 23.85 | 0.191042E+10 | 2606.54 | 20-APR-13:09 | 33.50 | 26.37 |
May | 0.211975E+11 | 29570.98 | 22-MAY-04:04 | 27.00 | 26.56 | 0.207028E+10 | 2606.53 | 01-MAY-13:09 | 27.00 | 26.56 |
June | 0.209716E+11 | 29029.51 | 20-JUN-04:03 | 24.08 | 23.67 | 0.206461E+10 | 2606.54 | 28-JUN-13:09 | 34.17 | 26.79 |
July | 0.196368E+11 | 28809.38 | 06-JUL-04:03 | 25.17 | 23.75 | 0.191633E+10 | 2606.54 | 03-JUL-13:09 | 25.17 | 23.75 |
August | 0.204092E+11 | 29397.15 | 21-AUG-04:02 | 24.17 | 23.75 | 0.215163E+10 | 2606.53 | 04-AUG-13:09 | 24.17 | 23.75 |
September | 0.191217E+11 | 28816.03 | 06-SEP-04:03 | 25.52 | 24.40 | 0.190910E+10 | 2606.53 | 22-SEP-09:09 | 24.33 | 23.59 |
October | 0.194573E+11 | 29742.49 | 23-OCT-04:02 | 22.58 | 22.48 | 0.198564E+10 | 2606.54 | 30-OCT-13:09 | 24.42 | 24.31 |
November | 0.189966E+11 | 30334.94 | 27-NOV-05:02 | 22.00 | 20.87 | 0.196709E+10 | 2606.54 | 08-NOV-14:09 | 22.00 | 20.87 |
December | 0.188200E+11 | 29301.38 | 18-DEC-05:02 | 23.00 | 23.00 | 0.191417E+10 | 2606.54 | 21-DEC-10:09 | 26.17 | 20.56 |
Annual Sum or Average | 0.237672E+12 | 0.238299E+11 | ||||||||
Minimum of Months | 0.182401E+11 | 28770.64 | 22.00 | 20.87 | 0.180183E+10 | 2606.53 | 20.83 | 18.11 | ||
Maximum of Months | 0.211975E+11 | 33009.14 | 27.00 | 26.56 | 0.215214E+10 | 2606.55 | 34.17 | 26.79 |
Report: ZoneCoolingSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.210088E+11 | 33320.18 | 17-JAN-05:02 | 21.33 | 20.02 | 0.198282E+10 | 2606.62 | 24-JAN-10:30 | 23.70 | 19.15 |
February | 0.196286E+11 | 32786.22 | 06-FEB-05:02 | 23.17 | 21.81 | 0.179922E+10 | 2606.55 | 24-FEB-10:09 | 28.50 | 22.00 |
March | 0.231215E+11 | 32315.81 | 06-MAR-05:02 | 24.00 | 21.84 | 0.215103E+10 | 2606.55 | 03-MAR-10:09 | 24.00 | 21.84 |
April | 0.222116E+11 | 32575.64 | 10-APR-04:02 | 25.17 | 23.75 | 0.191097E+10 | 2606.54 | 20-APR-13:09 | 33.50 | 26.37 |
May | 0.233299E+11 | 31757.92 | 02-MAY-04:03 | 27.08 | 26.53 | 0.207036E+10 | 2606.54 | 25-MAY-13:09 | 31.17 | 27.76 |
June | 0.232175E+11 | 32552.68 | 26-JUN-04:03 | 24.00 | 23.59 | 0.206502E+10 | 2606.54 | 28-JUN-13:09 | 34.17 | 26.79 |
July | 0.213565E+11 | 32305.15 | 17-JUL-04:02 | 24.42 | 23.35 | 0.191515E+10 | 2606.53 | 03-JUL-13:09 | 24.42 | 23.35 |
August | 0.220386E+11 | 31769.61 | 28-AUG-04:02 | 25.33 | 24.05 | 0.214957E+10 | 2606.54 | 17-AUG-13:00 | 25.33 | 24.05 |
September | 0.208530E+11 | 31749.16 | 25-SEP-04:02 | 26.00 | 25.36 | 0.190796E+10 | 2606.54 | 14-SEP-13:09 | 26.00 | 25.36 |
October | 0.207283E+11 | 33358.84 | 23-OCT-04:02 | 22.58 | 22.48 | 0.198344E+10 | 2606.55 | 13-OCT-13:09 | 22.58 | 22.48 |
November | 0.202303E+11 | 32946.02 | 06-NOV-05:02 | 23.00 | 22.27 | 0.196416E+10 | 2606.55 | 16-NOV-14:09 | 29.85 | 25.47 |
December | 0.199390E+11 | 32870.41 | 18-DEC-05:02 | 23.00 | 23.00 | 0.190890E+10 | 2606.61 | 21-DEC-10:09 | 26.17 | 20.56 |
Annual Sum or Average | 0.257664E+12 | 0.238086E+11 | ||||||||
Minimum of Months | 0.196286E+11 | 31749.16 | 21.33 | 20.02 | 0.179922E+10 | 2606.53 | 22.58 | 19.15 | ||
Maximum of Months | 0.233299E+11 | 33358.84 | 27.08 | 26.53 | 0.215103E+10 | 2606.62 | 34.17 | 27.76 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.595952E+10 | 10098.15 | 02-JAN-05:02 | 23.28 | 23.04 | 0.419190E+09 | 549.49 | 24-JAN-10:30 | 23.70 | 19.15 |
February | 0.575793E+10 | 9826.64 | 21-FEB-05:02 | 25.00 | 21.63 | 0.380756E+09 | 549.48 | 15-FEB-14:00 | 25.00 | 21.63 |
March | 0.706438E+10 | 11482.86 | 19-MAR-15:32 | 34.80 | 24.95 | 0.454954E+09 | 549.48 | 03-MAR-10:09 | 34.80 | 24.95 |
April | 0.707495E+10 | 11510.19 | 30-APR-12:53 | 33.70 | 26.84 | 0.404580E+09 | 549.48 | 20-APR-13:00 | 33.70 | 26.84 |
May | 0.812038E+10 | 12084.93 | 29-MAY-13:02 | 34.17 | 27.98 | 0.438343E+09 | 549.48 | 30-MAY-13:00 | 28.00 | 26.50 |
June | 0.873789E+10 | 12168.21 | 11-JUN-12:32 | 34.00 | 28.11 | 0.437061E+09 | 549.48 | 16-JUN-13:00 | 36.00 | 27.59 |
July | 0.720272E+10 | 11622.61 | 04-JUL-16:02 | 31.17 | 25.29 | 0.406039E+09 | 549.47 | 17-JUL-13:00 | 32.00 | 26.09 |
August | 0.702485E+10 | 11656.20 | 13-AUG-13:32 | 34.00 | 28.60 | 0.455035E+09 | 549.48 | 17-AUG-13:00 | 27.00 | 26.21 |
September | 0.632241E+10 | 11554.55 | 04-SEP-13:23 | 32.50 | 27.86 | 0.404066E+09 | 549.47 | 07-SEP-13:00 | 32.00 | 27.49 |
October | 0.598319E+10 | 10226.59 | 29-OCT-13:43 | 30.73 | 25.71 | 0.419946E+09 | 549.48 | 13-OCT-13:09 | 30.73 | 25.71 |
November | 0.581059E+10 | 8958.46 | 13-NOV-05:02 | 25.00 | 24.24 | 0.415630E+09 | 549.48 | 16-NOV-14:09 | 29.85 | 25.47 |
December | 0.556880E+10 | 7934.83 | 25-DEC-15:32 | 31.00 | 22.56 | 0.403844E+09 | 549.49 | 21-DEC-10:09 | 31.00 | 22.56 |
Annual Sum or Average | 0.806276E+11 | 0.503944E+10 | ||||||||
Minimum of Months | 0.556880E+10 | 7934.83 | 23.28 | 21.63 | 0.380756E+09 | 549.47 | 23.70 | 19.15 | ||
Maximum of Months | 0.873789E+10 | 12168.21 | 34.80 | 28.60 | 0.455035E+09 | 549.49 | 36.00 | 27.59 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.485935E+10 | 9632.50 | 16-JAN-11:02 | 29.63 | 21.29 | 0.266019E+09 | 347.88 | 24-JAN-10:30 | 23.70 | 19.15 |
February | 0.481754E+10 | 10781.19 | 20-FEB-09:32 | 28.93 | 23.11 | 0.241527E+09 | 347.86 | 21-FEB-10:20 | 23.53 | 20.42 |
March | 0.596072E+10 | 10772.10 | 05-MAR-10:02 | 29.75 | 22.92 | 0.288294E+09 | 347.86 | 03-MAR-10:20 | 29.75 | 22.92 |
April | 0.585292E+10 | 10807.32 | 23-APR-09:53 | 29.20 | 23.96 | 0.256313E+09 | 347.86 | 20-APR-13:00 | 29.20 | 23.96 |
May | 0.582128E+10 | 10813.46 | 14-MAY-09:02 | 30.40 | 25.64 | 0.277428E+09 | 347.86 | 30-MAY-13:00 | 28.00 | 26.50 |
June | 0.594909E+10 | 10743.82 | 11-JUN-08:32 | 30.33 | 27.76 | 0.276571E+09 | 347.86 | 28-JUN-13:00 | 34.00 | 27.29 |
July | 0.498873E+10 | 8860.91 | 30-JUL-14:53 | 31.30 | 25.47 | 0.256889E+09 | 347.86 | 17-JUL-13:00 | 31.30 | 25.47 |
August | 0.535685E+10 | 10808.00 | 13-AUG-09:32 | 31.00 | 27.34 | 0.288059E+09 | 347.86 | 17-AUG-13:00 | 27.00 | 26.21 |
September | 0.499160E+10 | 10802.23 | 10-SEP-10:02 | 31.50 | 26.15 | 0.255942E+09 | 347.86 | 11-SEP-13:00 | 27.00 | 24.83 |
October | 0.469027E+10 | 8647.51 | 29-OCT-11:43 | 31.50 | 26.00 | 0.265970E+09 | 347.86 | 11-OCT-09:39 | 31.50 | 26.00 |
November | 0.455467E+10 | 9174.43 | 05-NOV-11:13 | 30.67 | 23.05 | 0.263398E+09 | 347.86 | 13-NOV-10:20 | 26.97 | 24.85 |
December | 0.448361E+10 | 7878.82 | 03-DEC-11:23 | 31.00 | 22.63 | 0.256408E+09 | 347.87 | 21-DEC-10:09 | 26.17 | 20.56 |
Annual Sum or Average | 0.623266E+11 | 0.319282E+10 | ||||||||
Minimum of Months | 0.448361E+10 | 7878.82 | 28.93 | 21.29 | 0.241527E+09 | 347.86 | 23.53 | 19.15 | ||
Maximum of Months | 0.596072E+10 | 10813.46 | 31.50 | 27.76 | 0.288294E+09 | 347.88 | 34.00 | 27.29 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.859283E+10 | 12160.90 | 29-JAN-12:13 | 30.17 | 23.18 | 0.422521E+09 | 581.05 | 04-JAN-14:09 | 30.17 | 23.18 |
February | 0.773014E+10 | 12121.78 | 20-FEB-11:32 | 31.17 | 23.91 | 0.382489E+09 | 578.52 | 21-FEB-14:20 | 34.67 | 21.94 |
March | 0.806193E+10 | 11804.16 | 19-MAR-12:53 | 35.80 | 24.30 | 0.455289E+09 | 549.48 | 06-MAR-14:00 | 35.80 | 24.30 |
April | 0.696619E+10 | 11229.47 | 02-APR-12:23 | 33.70 | 26.26 | 0.404517E+09 | 549.48 | 20-APR-13:00 | 34.50 | 26.74 |
May | 0.735102E+10 | 11480.43 | 29-MAY-13:02 | 34.17 | 27.98 | 0.438011E+09 | 549.48 | 30-MAY-13:00 | 28.00 | 26.50 |
June | 0.728512E+10 | 11298.58 | 11-JUN-12:32 | 34.00 | 28.11 | 0.436653E+09 | 549.48 | 28-JUN-13:00 | 34.00 | 27.29 |
July | 0.640043E+10 | 10877.72 | 30-JUL-14:53 | 31.30 | 25.47 | 0.405564E+09 | 549.47 | 10-JUL-13:00 | 31.30 | 25.47 |
August | 0.664698E+10 | 11180.69 | 13-AUG-13:32 | 34.00 | 28.60 | 0.454817E+09 | 549.48 | 17-AUG-13:00 | 27.00 | 26.21 |
September | 0.660003E+10 | 11397.10 | 04-SEP-13:23 | 32.50 | 27.86 | 0.404144E+09 | 549.47 | 29-SEP-13:00 | 32.00 | 28.16 |
October | 0.696233E+10 | 11922.40 | 29-OCT-11:43 | 31.50 | 26.00 | 0.420440E+09 | 549.48 | 13-OCT-13:09 | 31.50 | 26.00 |
November | 0.761031E+10 | 12111.14 | 11-NOV-12:32 | 31.60 | 26.03 | 0.416652E+09 | 553.64 | 20-NOV-14:09 | 31.00 | 24.79 |
December | 0.811567E+10 | 12406.59 | 25-DEC-15:32 | 31.00 | 22.56 | 0.407820E+09 | 585.08 | 26-DEC-14:09 | 31.17 | 22.67 |
Annual Sum or Average | 0.883230E+11 | 0.504892E+10 | ||||||||
Minimum of Months | 0.640043E+10 | 10877.72 | 30.17 | 22.56 | 0.382489E+09 | 549.47 | 27.00 | 21.94 | ||
Maximum of Months | 0.859283E+10 | 12406.59 | 35.80 | 28.60 | 0.455289E+09 | 585.08 | 35.80 | 28.16 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.496917E+10 | 12269.78 | 16-JAN-15:42 | 31.42 | 22.04 | 0.264409E+09 | 347.84 | 24-JAN-10:00 | 28.00 | 20.00 |
February | 0.487520E+10 | 12228.38 | 26-FEB-15:52 | 34.10 | 25.18 | 0.240323E+09 | 347.84 | 15-FEB-14:00 | 34.10 | 25.18 |
March | 0.602908E+10 | 12608.20 | 19-MAR-15:32 | 34.80 | 24.95 | 0.287440E+09 | 347.84 | 03-MAR-10:09 | 34.80 | 24.95 |
April | 0.582889E+10 | 12558.80 | 02-APR-17:42 | 30.33 | 26.40 | 0.255731E+09 | 347.84 | 20-APR-13:00 | 34.50 | 26.74 |
May | 0.577448E+10 | 12572.85 | 07-MAY-17:12 | 31.00 | 26.68 | 0.276756E+09 | 347.84 | 30-MAY-13:00 | 28.00 | 26.50 |
June | 0.586098E+10 | 12587.91 | 18-JUN-17:22 | 30.00 | 26.62 | 0.276047E+09 | 347.84 | 16-JUN-13:00 | 30.00 | 26.62 |
July | 0.498326E+10 | 12203.82 | 04-JUL-16:42 | 29.83 | 25.24 | 0.255933E+09 | 347.84 | 10-JUL-13:00 | 28.00 | 26.07 |
August | 0.527749E+10 | 12204.30 | 27-AUG-16:12 | 32.67 | 25.94 | 0.287159E+09 | 347.84 | 15-AUG-13:00 | 32.67 | 25.94 |
September | 0.495116E+10 | 12680.33 | 10-SEP-16:42 | 28.00 | 25.79 | 0.255038E+09 | 347.84 | 07-SEP-13:00 | 28.00 | 25.79 |
October | 0.472465E+10 | 11986.45 | 29-OCT-15:43 | 29.83 | 26.07 | 0.264850E+09 | 347.84 | 13-OCT-13:00 | 29.83 | 26.07 |
November | 0.463217E+10 | 12034.32 | 11-NOV-14:32 | 31.63 | 26.64 | 0.262325E+09 | 347.84 | 21-NOV-14:00 | 31.50 | 24.93 |
December | 0.461057E+10 | 12750.16 | 25-DEC-15:32 | 31.00 | 22.56 | 0.254450E+09 | 347.84 | 08-DEC-14:00 | 31.00 | 22.56 |
Annual Sum or Average | 0.625171E+11 | 0.318046E+10 | ||||||||
Minimum of Months | 0.461057E+10 | 11986.45 | 28.00 | 22.04 | 0.240323E+09 | 347.84 | 28.00 | 20.00 | ||
Maximum of Months | 0.602908E+10 | 12750.16 | 34.80 | 26.68 | 0.287440E+09 | 347.84 | 34.80 | 26.74 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.595661E+10 | 7442.58 | 02-JAN-07:03 | 23.85 | 23.26 | 0.419912E+09 | 549.48 | 24-JAN-10:09 | 20.83 | 18.11 |
February | 0.563073E+10 | 7772.76 | 27-FEB-05:02 | 24.00 | 22.49 | 0.381102E+09 | 549.48 | 21-FEB-10:09 | 24.00 | 22.49 |
March | 0.670615E+10 | 7781.11 | 20-MAR-04:02 | 27.08 | 23.58 | 0.455057E+09 | 549.48 | 03-MAR-10:09 | 27.08 | 23.58 |
April | 0.666878E+10 | 7859.93 | 17-APR-04:02 | 26.92 | 25.03 | 0.404427E+09 | 549.48 | 20-APR-13:09 | 33.50 | 26.37 |
May | 0.789890E+10 | 9961.16 | 29-MAY-13:02 | 34.17 | 27.98 | 0.438459E+09 | 549.48 | 30-MAY-13:00 | 28.00 | 26.50 |
June | 0.854621E+10 | 10084.60 | 11-JUN-12:32 | 34.00 | 28.11 | 0.437366E+09 | 557.37 | 12-JUN-13:00 | 34.00 | 27.86 |
July | 0.732690E+10 | 8023.99 | 03-JUL-04:02 | 25.00 | 22.79 | 0.406342E+09 | 549.48 | 10-JUL-13:00 | 28.00 | 26.07 |
August | 0.715417E+10 | 8450.78 | 14-AUG-04:02 | 26.33 | 25.57 | 0.455485E+09 | 549.48 | 17-AUG-13:09 | 27.50 | 25.43 |
September | 0.636774E+10 | 7828.46 | 05-SEP-04:02 | 26.75 | 26.18 | 0.404361E+09 | 549.48 | 11-SEP-13:00 | 27.00 | 24.83 |
October | 0.600505E+10 | 7961.35 | 02-OCT-04:02 | 24.00 | 23.36 | 0.420400E+09 | 549.48 | 30-OCT-13:00 | 24.00 | 24.00 |
November | 0.585776E+10 | 7891.40 | 13-NOV-05:02 | 25.00 | 24.24 | 0.416063E+09 | 549.48 | 13-NOV-14:00 | 30.00 | 25.82 |
December | 0.562731E+10 | 6722.37 | 18-DEC-05:02 | 23.00 | 23.00 | 0.405019E+09 | 549.48 | 04-DEC-14:00 | 23.00 | 23.00 |
Annual Sum or Average | 0.797463E+11 | 0.504399E+10 | ||||||||
Minimum of Months | 0.562731E+10 | 6722.37 | 23.00 | 22.49 | 0.381102E+09 | 549.48 | 20.83 | 18.11 | ||
Maximum of Months | 0.854621E+10 | 10084.60 | 34.17 | 28.11 | 0.455485E+09 | 557.37 | 34.00 | 27.86 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.486119E+10 | 6994.62 | 16-JAN-11:23 | 29.90 | 21.44 | 0.266393E+09 | 347.86 | 31-JAN-10:09 | 24.17 | 21.37 |
February | 0.474900E+10 | 9579.12 | 20-FEB-09:53 | 29.40 | 22.77 | 0.241791E+09 | 347.86 | 21-FEB-10:20 | 23.53 | 20.42 |
March | 0.573371E+10 | 9486.98 | 05-MAR-10:02 | 29.75 | 22.92 | 0.288572E+09 | 347.86 | 03-MAR-10:09 | 29.75 | 22.92 |
April | 0.555348E+10 | 9488.98 | 16-APR-10:32 | 31.57 | 25.77 | 0.256483E+09 | 347.86 | 20-APR-13:00 | 34.50 | 26.74 |
May | 0.564756E+10 | 9559.21 | 29-MAY-07:42 | 29.73 | 27.64 | 0.277725E+09 | 347.86 | 30-MAY-13:00 | 28.00 | 26.50 |
June | 0.579227E+10 | 9504.96 | 11-JUN-08:32 | 30.33 | 27.76 | 0.276795E+09 | 347.86 | 16-JUN-13:00 | 36.00 | 27.59 |
July | 0.501415E+10 | 7485.08 | 31-JUL-04:02 | 24.35 | 23.15 | 0.257285E+09 | 347.86 | 17-JUL-13:00 | 24.35 | 23.15 |
August | 0.540949E+10 | 9525.79 | 13-AUG-09:32 | 31.00 | 27.34 | 0.288551E+09 | 347.86 | 04-AUG-09:00 | 31.00 | 27.34 |
September | 0.499231E+10 | 9573.00 | 04-SEP-10:32 | 30.07 | 27.05 | 0.256366E+09 | 347.86 | 11-SEP-13:00 | 27.00 | 24.83 |
October | 0.466582E+10 | 7910.12 | 08-OCT-08:32 | 29.00 | 25.89 | 0.266495E+09 | 347.86 | 11-OCT-09:30 | 29.05 | 25.81 |
November | 0.456838E+10 | 7361.96 | 13-NOV-05:02 | 25.00 | 24.24 | 0.263849E+09 | 347.86 | 13-NOV-10:30 | 27.55 | 25.00 |
December | 0.452094E+10 | 7346.24 | 31-DEC-09:32 | 29.87 | 24.27 | 0.257018E+09 | 347.86 | 29-DEC-10:30 | 29.87 | 24.27 |
Annual Sum or Average | 0.615083E+11 | 0.319732E+10 | ||||||||
Minimum of Months | 0.452094E+10 | 6994.62 | 24.35 | 21.44 | 0.241791E+09 | 347.86 | 23.53 | 20.42 | ||
Maximum of Months | 0.579227E+10 | 9579.12 | 31.57 | 27.76 | 0.288572E+09 | 347.86 | 36.00 | 27.59 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.949887E+10 | 10488.27 | 04-JAN-13:00 | 34.10 | 23.67 | 0.441820E+09 | 746.66 | 04-JAN-13:09 | 34.08 | 23.62 |
February | 0.856650E+10 | 10397.80 | 21-FEB-13:00 | 34.10 | 22.08 | 0.402146E+09 | 741.33 | 21-FEB-13:09 | 34.25 | 22.07 |
March | 0.947568E+10 | 10313.72 | 21-MAR-12:00 | 35.00 | 23.21 | 0.469718E+09 | 732.66 | 21-MAR-12:09 | 35.23 | 23.19 |
April | 0.840085E+10 | 9876.50 | 18-APR-12:00 | 34.00 | 26.52 | 0.412182E+09 | 691.37 | 18-APR-12:09 | 34.03 | 26.51 |
May | 0.901513E+10 | 10676.37 | 05-MAY-12:00 | 37.00 | 25.95 | 0.447389E+09 | 759.86 | 05-MAY-12:09 | 36.90 | 26.19 |
June | 0.904262E+10 | 10218.27 | 16-JUN-12:00 | 35.00 | 28.16 | 0.446417E+09 | 717.04 | 16-JUN-12:09 | 35.17 | 28.24 |
July | 0.774088E+10 | 9402.73 | 26-JUL-17:00 | 33.00 | 26.23 | 0.409908E+09 | 634.56 | 27-JUL-12:09 | 31.48 | 25.75 |
August | 0.842707E+10 | 9876.02 | 15-AUG-12:00 | 33.70 | 27.96 | 0.460862E+09 | 688.54 | 15-AUG-12:09 | 33.32 | 27.86 |
September | 0.800352E+10 | 9701.24 | 05-SEP-12:00 | 33.00 | 26.98 | 0.410281E+09 | 676.34 | 05-SEP-12:09 | 33.02 | 26.93 |
October | 0.818323E+10 | 9887.90 | 29-OCT-11:43 | 31.50 | 26.00 | 0.427340E+09 | 675.02 | 04-OCT-12:09 | 31.50 | 26.00 |
November | 0.876172E+10 | 9975.28 | 19-NOV-11:32 | 32.10 | 24.51 | 0.429969E+09 | 678.85 | 13-NOV-13:09 | 32.10 | 24.51 |
December | 0.900075E+10 | 10387.11 | 25-DEC-13:22 | 30.50 | 23.89 | 0.424101E+09 | 712.99 | 26-DEC-13:09 | 32.00 | 23.12 |
Annual Sum or Average | 0.104117E+12 | 0.518213E+10 | ||||||||
Minimum of Months | 0.774088E+10 | 9402.73 | 30.50 | 22.08 | 0.402146E+09 | 634.56 | 31.48 | 22.07 | ||
Maximum of Months | 0.949887E+10 | 10676.37 | 37.00 | 28.16 | 0.469718E+09 | 759.86 | 36.90 | 28.24 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.484473E+10 | 10091.91 | 08-JAN-15:53 | 31.70 | 23.20 | 0.266204E+09 | 347.84 | 09-JAN-14:00 | 31.00 | 24.49 |
February | 0.469738E+10 | 10550.84 | 20-FEB-15:52 | 33.10 | 24.35 | 0.241576E+09 | 347.84 | 21-FEB-10:09 | 21.92 | 19.78 |
March | 0.571602E+10 | 10295.54 | 19-MAR-15:32 | 34.80 | 24.95 | 0.288464E+09 | 347.84 | 03-MAR-10:09 | 34.80 | 24.95 |
April | 0.545620E+10 | 10409.25 | 02-APR-17:42 | 30.33 | 26.40 | 0.256353E+09 | 347.84 | 20-APR-13:00 | 34.50 | 26.74 |
May | 0.553888E+10 | 10363.16 | 07-MAY-17:12 | 31.00 | 26.68 | 0.277568E+09 | 347.84 | 30-MAY-13:00 | 28.00 | 26.50 |
June | 0.567355E+10 | 10405.92 | 18-JUN-17:22 | 30.00 | 26.62 | 0.276698E+09 | 347.84 | 16-JUN-13:00 | 30.00 | 26.62 |
July | 0.494014E+10 | 9660.40 | 04-JUL-16:02 | 31.17 | 25.29 | 0.257189E+09 | 347.84 | 10-JUL-13:00 | 28.00 | 26.07 |
August | 0.527701E+10 | 9685.47 | 27-AUG-16:12 | 32.67 | 25.94 | 0.288465E+09 | 347.84 | 15-AUG-13:00 | 32.67 | 25.94 |
September | 0.487892E+10 | 10450.37 | 10-SEP-16:42 | 28.00 | 25.79 | 0.256198E+09 | 347.84 | 07-SEP-13:00 | 28.00 | 25.79 |
October | 0.461033E+10 | 8926.15 | 29-OCT-15:43 | 29.83 | 26.07 | 0.266372E+09 | 347.84 | 30-OCT-13:00 | 24.00 | 24.00 |
November | 0.454305E+10 | 9017.85 | 19-NOV-16:53 | 29.50 | 25.36 | 0.263633E+09 | 347.84 | 21-NOV-14:00 | 31.50 | 24.93 |
December | 0.451052E+10 | 10375.07 | 25-DEC-15:22 | 31.00 | 22.72 | 0.256744E+09 | 347.84 | 08-DEC-14:00 | 31.00 | 22.72 |
Annual Sum or Average | 0.606867E+11 | 0.319546E+10 | ||||||||
Minimum of Months | 0.451052E+10 | 8926.15 | 28.00 | 22.72 | 0.241576E+09 | 347.84 | 21.92 | 19.78 | ||
Maximum of Months | 0.571602E+10 | 10550.84 | 34.80 | 26.68 | 0.288465E+09 | 347.84 | 34.80 | 26.74 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.559167E+10 | 8054.73 | 02-JAN-05:02 | 23.28 | 23.04 | 0.419821E+09 | 549.48 | 24-JAN-10:09 | 20.83 | 18.11 |
February | 0.532926E+10 | 7995.71 | 27-FEB-05:02 | 24.00 | 22.49 | 0.381094E+09 | 549.48 | 21-FEB-10:09 | 24.00 | 22.49 |
March | 0.642250E+10 | 7801.42 | 13-MAR-04:02 | 26.17 | 24.04 | 0.455081E+09 | 549.48 | 03-MAR-10:09 | 26.17 | 24.04 |
April | 0.633879E+10 | 8125.47 | 10-APR-04:02 | 25.17 | 23.75 | 0.404454E+09 | 549.48 | 20-APR-13:09 | 33.50 | 26.37 |
May | 0.735642E+10 | 9875.83 | 29-MAY-13:02 | 34.17 | 27.98 | 0.438363E+09 | 549.48 | 30-MAY-13:00 | 28.00 | 26.50 |
June | 0.789856E+10 | 10041.86 | 11-JUN-12:32 | 34.00 | 28.11 | 0.437034E+09 | 549.48 | 16-JUN-13:00 | 36.00 | 27.59 |
July | 0.658964E+10 | 8869.91 | 04-JUL-15:22 | 31.75 | 25.05 | 0.406128E+09 | 549.47 | 17-JUL-13:00 | 32.00 | 26.09 |
August | 0.647664E+10 | 9205.07 | 13-AUG-13:32 | 34.00 | 28.60 | 0.455238E+09 | 549.47 | 15-AUG-13:00 | 27.00 | 27.00 |
September | 0.578048E+10 | 7971.73 | 25-SEP-04:02 | 26.00 | 25.36 | 0.404185E+09 | 549.47 | 07-SEP-13:00 | 26.00 | 25.36 |
October | 0.558363E+10 | 8228.97 | 02-OCT-04:02 | 24.00 | 23.36 | 0.420254E+09 | 549.47 | 30-OCT-13:00 | 24.00 | 24.00 |
November | 0.543886E+10 | 8099.14 | 24-NOV-05:02 | 24.42 | 21.44 | 0.415965E+09 | 549.48 | 09-NOV-14:00 | 24.42 | 21.44 |
December | 0.522183E+10 | 8062.79 | 26-DEC-05:02 | 22.00 | 21.88 | 0.404754E+09 | 549.48 | 04-DEC-14:00 | 22.00 | 21.88 |
Annual Sum or Average | 0.740283E+11 | 0.504237E+10 | ||||||||
Minimum of Months | 0.522183E+10 | 7801.42 | 22.00 | 21.44 | 0.381094E+09 | 549.47 | 20.83 | 18.11 | ||
Maximum of Months | 0.789856E+10 | 10041.86 | 34.17 | 28.60 | 0.455238E+09 | 549.48 | 36.00 | 27.59 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.449221E+10 | 7452.53 | 16-JAN-11:23 | 29.90 | 21.44 | 0.197058E+09 | 338.73 | 23-JAN-08:20 | 22.27 | 18.63 |
February | 0.440681E+10 | 10133.02 | 20-FEB-09:23 | 28.70 | 23.27 | 0.178848E+09 | 338.73 | 24-FEB-08:20 | 23.67 | 18.66 |
March | 0.537567E+10 | 10109.69 | 05-MAR-10:02 | 29.75 | 22.92 | 0.212938E+09 | 338.72 | 03-MAR-08:20 | 29.75 | 22.92 |
April | 0.521037E+10 | 10122.94 | 23-APR-09:53 | 29.20 | 23.96 | 0.189710E+09 | 338.72 | 18-APR-12:20 | 29.20 | 23.96 |
May | 0.521069E+10 | 10153.48 | 14-MAY-09:02 | 30.40 | 25.64 | 0.205233E+09 | 338.72 | 31-MAY-12:20 | 34.13 | 27.34 |
June | 0.531872E+10 | 10109.38 | 11-JUN-08:32 | 30.33 | 27.76 | 0.204310E+09 | 338.72 | 06-JUN-12:20 | 30.33 | 27.76 |
July | 0.450181E+10 | 7308.09 | 31-JUL-04:02 | 24.35 | 23.15 | 0.190370E+09 | 338.72 | 13-JUL-07:19 | 24.35 | 23.15 |
August | 0.486603E+10 | 10124.66 | 13-AUG-09:32 | 31.00 | 27.34 | 0.212776E+09 | 338.72 | 16-AUG-12:20 | 31.87 | 27.70 |
September | 0.449262E+10 | 10104.15 | 10-SEP-10:02 | 31.50 | 26.15 | 0.189454E+09 | 338.72 | 06-SEP-12:20 | 31.50 | 26.15 |
October | 0.430133E+10 | 9386.50 | 08-OCT-08:32 | 29.00 | 25.89 | 0.197049E+09 | 338.72 | 12-OCT-07:19 | 25.93 | 25.11 |
November | 0.418461E+10 | 7177.46 | 13-NOV-07:03 | 26.08 | 24.64 | 0.195122E+09 | 338.72 | 08-NOV-13:20 | 26.08 | 24.64 |
December | 0.414106E+10 | 8850.62 | 31-DEC-09:32 | 29.87 | 24.27 | 0.190078E+09 | 338.72 | 21-DEC-08:30 | 29.87 | 24.27 |
Annual Sum or Average | 0.565019E+11 | 0.236294E+10 | ||||||||
Minimum of Months | 0.414106E+10 | 7177.46 | 24.35 | 21.44 | 0.178848E+09 | 338.72 | 22.27 | 18.63 | ||
Maximum of Months | 0.537567E+10 | 10153.48 | 31.50 | 27.76 | 0.212938E+09 | 338.73 | 34.13 | 27.76 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.796086E+10 | 10246.29 | 08-JAN-13:53 | 32.50 | 22.83 | 0.425662E+09 | 595.31 | 17-JAN-14:09 | 30.95 | 22.65 |
February | 0.710548E+10 | 10046.81 | 20-FEB-11:23 | 31.00 | 23.86 | 0.384385E+09 | 591.49 | 21-FEB-14:09 | 34.83 | 21.98 |
March | 0.732635E+10 | 9751.65 | 19-MAR-12:53 | 35.80 | 24.30 | 0.455427E+09 | 549.48 | 06-MAR-14:00 | 35.80 | 24.30 |
April | 0.624641E+10 | 7915.61 | 10-APR-04:02 | 25.17 | 23.75 | 0.404393E+09 | 549.48 | 20-APR-13:09 | 33.50 | 26.37 |
May | 0.666284E+10 | 9332.31 | 29-MAY-13:02 | 34.17 | 27.98 | 0.438017E+09 | 549.48 | 30-MAY-13:00 | 28.00 | 26.50 |
June | 0.659027E+10 | 7816.49 | 13-JUN-04:02 | 27.08 | 26.29 | 0.436572E+09 | 549.48 | 16-JUN-13:00 | 36.00 | 27.59 |
July | 0.586251E+10 | 7814.39 | 17-JUL-04:02 | 24.42 | 23.35 | 0.405728E+09 | 549.47 | 10-JUL-13:00 | 24.42 | 23.35 |
August | 0.613917E+10 | 7658.84 | 25-AUG-05:03 | 26.00 | 26.00 | 0.455062E+09 | 549.47 | 15-AUG-13:00 | 26.00 | 26.00 |
September | 0.602759E+10 | 8674.52 | 04-SEP-13:23 | 32.50 | 27.86 | 0.404279E+09 | 549.47 | 29-SEP-13:00 | 32.00 | 28.16 |
October | 0.647987E+10 | 9941.03 | 29-OCT-11:43 | 31.50 | 26.00 | 0.420733E+09 | 549.48 | 13-OCT-13:00 | 31.50 | 26.00 |
November | 0.707465E+10 | 10034.34 | 19-NOV-11:32 | 32.10 | 24.51 | 0.417808E+09 | 566.95 | 20-NOV-14:09 | 31.00 | 24.79 |
December | 0.752915E+10 | 10443.88 | 31-DEC-12:52 | 32.00 | 25.00 | 0.410970E+09 | 599.48 | 26-DEC-14:09 | 32.00 | 25.00 |
Annual Sum or Average | 0.810052E+11 | 0.505904E+10 | ||||||||
Minimum of Months | 0.586251E+10 | 7658.84 | 24.42 | 22.83 | 0.384385E+09 | 549.47 | 24.42 | 21.98 | ||
Maximum of Months | 0.796086E+10 | 10443.88 | 35.80 | 27.98 | 0.455427E+09 | 599.48 | 36.00 | 28.16 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.458342E+10 | 11127.74 | 29-JAN-16:02 | 32.08 | 23.28 | 0.265584E+09 | 347.84 | 24-JAN-10:09 | 32.08 | 23.28 |
February | 0.446397E+10 | 10849.19 | 20-FEB-16:02 | 32.58 | 24.26 | 0.241107E+09 | 347.84 | 21-FEB-10:09 | 21.92 | 19.78 |
March | 0.545757E+10 | 11052.60 | 19-MAR-15:32 | 34.80 | 24.95 | 0.288045E+09 | 347.84 | 03-MAR-10:09 | 34.80 | 24.95 |
April | 0.520562E+10 | 11092.82 | 02-APR-16:22 | 32.75 | 27.02 | 0.256046E+09 | 347.84 | 20-APR-13:00 | 34.50 | 26.74 |
May | 0.520438E+10 | 10938.65 | 07-MAY-17:12 | 31.00 | 26.68 | 0.277161E+09 | 347.84 | 30-MAY-13:00 | 28.00 | 26.50 |
June | 0.528468E+10 | 11005.09 | 18-JUN-17:22 | 30.00 | 26.62 | 0.276324E+09 | 347.84 | 16-JUN-13:00 | 30.00 | 26.62 |
July | 0.451260E+10 | 10751.58 | 04-JUL-16:02 | 31.17 | 25.29 | 0.256596E+09 | 347.84 | 10-JUL-13:00 | 28.00 | 26.07 |
August | 0.483176E+10 | 10680.05 | 27-AUG-16:12 | 32.67 | 25.94 | 0.287873E+09 | 347.84 | 15-AUG-13:00 | 32.67 | 25.94 |
September | 0.447890E+10 | 11154.29 | 10-SEP-16:42 | 28.00 | 25.79 | 0.255651E+09 | 347.84 | 07-SEP-13:00 | 28.00 | 25.79 |
October | 0.434290E+10 | 9835.94 | 29-OCT-15:43 | 29.83 | 26.07 | 0.265712E+09 | 347.84 | 13-OCT-13:00 | 29.83 | 26.07 |
November | 0.426708E+10 | 9644.58 | 11-NOV-15:02 | 31.32 | 26.67 | 0.263099E+09 | 347.84 | 09-NOV-14:00 | 31.32 | 26.67 |
December | 0.424224E+10 | 11122.58 | 25-DEC-15:22 | 31.00 | 22.72 | 0.255935E+09 | 347.84 | 08-DEC-14:00 | 31.00 | 22.72 |
Annual Sum or Average | 0.568751E+11 | 0.318913E+10 | ||||||||
Minimum of Months | 0.424224E+10 | 9644.58 | 28.00 | 22.72 | 0.241107E+09 | 347.84 | 21.92 | 19.78 | ||
Maximum of Months | 0.545757E+10 | 11154.29 | 34.80 | 27.02 | 0.288045E+09 | 347.84 | 34.80 | 26.74 |
Report: ZoneHeatingSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 25.03 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 28.62 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 23.80 | |
Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 21738556.92 | 5622.45 | 23-JAN-06:03 | 18.83 |
February | 19474359.78 | 5044.40 | 21-FEB-05:02 | 25.00 |
March | 15680420.29 | 4144.96 | 20-MAR-04:02 | 27.08 |
April | 11912455.49 | 3955.06 | 10-APR-04:02 | 25.17 |
May | 13423949.55 | 3603.81 | 15-MAY-04:02 | 26.33 |
June | 12852395.45 | 4004.35 | 12-JUN-04:02 | 26.33 |
July | 14457610.61 | 4518.18 | 17-JUL-04:02 | 24.42 |
August | 13698770.11 | 4215.11 | 28-AUG-04:02 | 25.33 |
September | 12786770.84 | 4075.31 | 25-SEP-04:02 | 26.00 |
October | 14152657.32 | 4225.40 | 02-OCT-04:02 | 24.00 |
November | 15581139.26 | 4548.32 | 13-NOV-05:02 | 25.00 |
December | 22966981.17 | 4049.66 | 11-DEC-05:02 | 23.00 |
Annual Sum or Average | 0.188726E+09 | |||
Minimum of Months | 11912455.49 | 3603.81 | 18.83 | |
Maximum of Months | 22966981.17 | 5622.45 | 27.08 |
Report: ZoneHeatingSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 11264978.70 | 1851.26 | 11-JAN-06:03 | 24.70 |
February | 8380170.49 | 1682.22 | 10-FEB-06:03 | 23.75 |
March | 9503993.04 | 1838.56 | 13-MAR-04:02 | 26.17 |
April | 8179520.72 | 1926.34 | 17-APR-04:02 | 26.92 |
May | 10341063.70 | 2084.20 | 22-MAY-04:02 | 27.00 |
June | 9287567.10 | 1969.06 | 06-JUN-04:03 | 26.83 |
July | 9390650.85 | 2027.01 | 24-JUL-04:02 | 25.67 |
August | 8710946.90 | 2195.33 | 18-AUG-05:03 | 25.83 |
September | 8829197.71 | 2082.56 | 01-SEP-05:03 | 26.00 |
October | 9454568.28 | 2046.75 | 26-OCT-05:03 | 25.00 |
November | 10441280.24 | 1931.24 | 24-NOV-05:02 | 24.42 |
December | 11912594.16 | 1876.31 | 18-DEC-05:02 | 23.00 |
Annual Sum or Average | 0.115697E+09 | |||
Minimum of Months | 8179520.72 | 1682.22 | 23.00 | |
Maximum of Months | 11912594.16 | 2195.33 | 27.00 |
Report: ZoneHeatingSummaryMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 24996263.68 | 3158.96 | 05-JAN-05:03 | 24.23 |
February | 18886852.62 | 3053.06 | 23-FEB-05:03 | 24.08 |
March | 19630067.83 | 3208.12 | 30-MAR-04:03 | 26.83 |
April | 17212813.67 | 3298.28 | 12-APR-04:03 | 27.08 |
May | 21326369.20 | 3511.82 | 10-MAY-04:03 | 28.33 |
June | 19567806.80 | 3475.18 | 06-JUN-04:03 | 26.83 |
July | 22271255.38 | 3228.45 | 03-JUL-04:02 | 25.00 |
August | 22065017.81 | 3738.45 | 02-AUG-04:03 | 29.25 |
September | 21614261.82 | 3523.50 | 18-SEP-04:03 | 25.42 |
October | 20488220.73 | 3209.03 | 24-OCT-04:03 | 24.08 |
November | 23275898.67 | 3273.32 | 14-NOV-05:03 | 26.00 |
December | 24917200.03 | 3202.29 | 18-DEC-05:02 | 23.00 |
Annual Sum or Average | 0.256252E+09 | |||
Minimum of Months | 17212813.67 | 3053.06 | 23.00 | |
Maximum of Months | 24996263.68 | 3738.45 | 29.25 |
Report: ZoneHeatingSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 25.03 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 28.62 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 23.80 | |
Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 25.03 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 28.62 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 23.80 | |
Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 25.03 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 28.62 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 23.80 | |
Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 25.03 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 28.62 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 23.80 | |
Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 25.03 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 28.62 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 23.80 | |
Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 25.03 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 28.62 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 23.80 | |
Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 25.03 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 28.62 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 23.80 | |
Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 25.03 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 28.62 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 23.80 | |
Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 25.03 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 28.62 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 23.80 | |
Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 25.03 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 28.62 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 23.80 | |
Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 25.03 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 28.62 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 23.80 | |
Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 25.03 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 28.62 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 23.80 | |
Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 25.03 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 28.62 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 23.80 | |
Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 25.03 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 26.43 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 25.93 |
April | 0.00 | 0.00 | 01-APR-00:10 | 27.53 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 28.62 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 24.05 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 25.40 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.63 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.53 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.27 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 25.22 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 23.80 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 23.80 | |
Maximum of Months | 0.00 | 0.00 | 28.62 |
Report: ZoneElectricSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.403280E+10 | 4220.20 | 02-JAN-08:09 | 0.198672E+11 | 18185.19 | 02-JAN-08:09 |
February | 0.365805E+10 | 4220.20 | 01-FEB-08:09 | 0.179823E+11 | 18185.19 | 01-FEB-08:09 |
March | 0.434679E+10 | 4220.20 | 01-MAR-08:09 | 0.207117E+11 | 18185.19 | 01-MAR-08:09 |
April | 0.388256E+10 | 4220.20 | 03-APR-07:10 | 0.191625E+11 | 18185.19 | 03-APR-07:10 |
May | 0.418979E+10 | 4220.20 | 01-MAY-07:10 | 0.202894E+11 | 18185.19 | 01-MAY-07:10 |
June | 0.416954E+10 | 4220.20 | 01-JUN-07:10 | 0.199404E+11 | 18185.19 | 01-JUN-07:10 |
July | 0.390282E+10 | 4220.20 | 03-JUL-07:10 | 0.195094E+11 | 18185.19 | 03-JUL-07:10 |
August | 0.434679E+10 | 4220.20 | 01-AUG-07:10 | 0.207117E+11 | 18185.19 | 01-AUG-07:10 |
September | 0.388256E+10 | 4220.20 | 01-SEP-07:10 | 0.191582E+11 | 18185.19 | 01-SEP-07:10 |
October | 0.403280E+10 | 4220.20 | 02-OCT-07:10 | 0.198694E+11 | 18185.19 | 02-OCT-07:10 |
November | 0.398554E+10 | 4220.20 | 01-NOV-07:10 | 0.194582E+11 | 18185.19 | 01-NOV-07:10 |
December | 0.390282E+10 | 4220.20 | 01-DEC-08:09 | 0.195072E+11 | 18185.19 | 01-DEC-08:09 |
Annual Sum or Average | 0.483329E+11 | 0.236167E+12 | ||||
Minimum of Months | 0.365805E+10 | 4220.20 | 0.179823E+11 | 18185.19 | ||
Maximum of Months | 0.434679E+10 | 4220.20 | 0.207117E+11 | 18185.19 |
Report: ZoneElectricSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.403280E+10 | 4220.20 | 02-JAN-08:09 | 0.971303E+10 | 6808.32 | 02-JAN-08:09 |
February | 0.365805E+10 | 4220.20 | 01-FEB-08:09 | 0.879311E+10 | 6808.32 | 01-FEB-08:09 |
March | 0.434679E+10 | 4220.20 | 01-MAR-08:09 | 0.101015E+11 | 6808.32 | 01-MAR-08:09 |
April | 0.388256E+10 | 4220.20 | 03-APR-07:10 | 0.937947E+10 | 6808.32 | 03-APR-07:10 |
May | 0.418979E+10 | 4220.20 | 01-MAY-07:10 | 0.990724E+10 | 6808.32 | 01-MAY-07:10 |
June | 0.416954E+10 | 4220.20 | 01-JUN-07:10 | 0.972788E+10 | 6808.32 | 01-JUN-07:10 |
July | 0.390282E+10 | 4220.20 | 03-JUL-07:10 | 0.955663E+10 | 6808.32 | 03-JUL-07:10 |
August | 0.434679E+10 | 4220.20 | 01-AUG-07:10 | 0.101015E+11 | 6808.32 | 01-AUG-07:10 |
September | 0.388256E+10 | 4220.20 | 01-SEP-07:10 | 0.937507E+10 | 6808.32 | 01-SEP-07:10 |
October | 0.403280E+10 | 4220.20 | 02-OCT-07:10 | 0.971523E+10 | 6808.32 | 02-OCT-07:10 |
November | 0.398554E+10 | 4220.20 | 01-NOV-07:10 | 0.950025E+10 | 6808.32 | 01-NOV-07:10 |
December | 0.390282E+10 | 4220.20 | 01-DEC-08:09 | 0.955443E+10 | 6808.32 | 01-DEC-08:09 |
Annual Sum or Average | 0.483329E+11 | 0.115425E+12 | ||||
Minimum of Months | 0.365805E+10 | 4220.20 | 0.879311E+10 | 6808.32 | ||
Maximum of Months | 0.434679E+10 | 4220.20 | 0.101015E+11 | 6808.32 |
Report: ZoneElectricSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.403280E+10 | 4220.20 | 02-JAN-08:09 | 0.971303E+10 | 6808.32 | 02-JAN-08:09 |
February | 0.365805E+10 | 4220.20 | 01-FEB-08:09 | 0.879311E+10 | 6808.32 | 01-FEB-08:09 |
March | 0.434679E+10 | 4220.20 | 01-MAR-08:09 | 0.101015E+11 | 6808.32 | 01-MAR-08:09 |
April | 0.388256E+10 | 4220.20 | 03-APR-07:10 | 0.937947E+10 | 6808.32 | 03-APR-07:10 |
May | 0.418979E+10 | 4220.20 | 01-MAY-07:10 | 0.990724E+10 | 6808.32 | 01-MAY-07:10 |
June | 0.416954E+10 | 4220.20 | 01-JUN-07:10 | 0.972788E+10 | 6808.32 | 01-JUN-07:10 |
July | 0.390282E+10 | 4220.20 | 03-JUL-07:10 | 0.955663E+10 | 6808.32 | 03-JUL-07:10 |
August | 0.434679E+10 | 4220.20 | 01-AUG-07:10 | 0.101015E+11 | 6808.32 | 01-AUG-07:10 |
September | 0.388256E+10 | 4220.20 | 01-SEP-07:10 | 0.937507E+10 | 6808.32 | 01-SEP-07:10 |
October | 0.403280E+10 | 4220.20 | 02-OCT-07:10 | 0.971523E+10 | 6808.32 | 02-OCT-07:10 |
November | 0.398554E+10 | 4220.20 | 01-NOV-07:10 | 0.950025E+10 | 6808.32 | 01-NOV-07:10 |
December | 0.390282E+10 | 4220.20 | 01-DEC-08:09 | 0.955443E+10 | 6808.32 | 01-DEC-08:09 |
Annual Sum or Average | 0.483329E+11 | 0.115425E+12 | ||||
Minimum of Months | 0.365805E+10 | 4220.20 | 0.879311E+10 | 6808.32 | ||
Maximum of Months | 0.434679E+10 | 4220.20 | 0.101015E+11 | 6808.32 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.504932E+09 | 714.39 | 02-JAN-16:00 | 0.204758E+10 | 1435.25 | 02-JAN-08:09 |
February | 0.451465E+09 | 545.77 | 07-FEB-16:00 | 0.185366E+10 | 1435.25 | 01-FEB-08:09 |
March | 0.520874E+09 | 596.97 | 01-MAR-16:00 | 0.212947E+10 | 1435.25 | 01-MAR-08:09 |
April | 0.457022E+09 | 471.25 | 21-APR-07:10 | 0.197726E+10 | 1435.25 | 03-APR-07:10 |
May | 0.492253E+09 | 477.76 | 17-MAY-07:10 | 0.208852E+10 | 1435.25 | 01-MAY-07:10 |
June | 0.484527E+09 | 465.76 | 20-JUN-07:10 | 0.205071E+10 | 1435.25 | 01-JUN-07:10 |
July | 0.458286E+09 | 469.82 | 11-JUL-07:10 | 0.201461E+10 | 1435.25 | 03-JUL-07:10 |
August | 0.510329E+09 | 474.04 | 21-AUG-07:10 | 0.212947E+10 | 1435.25 | 01-AUG-07:10 |
September | 0.465921E+09 | 474.18 | 21-SEP-07:10 | 0.197634E+10 | 1435.25 | 01-SEP-07:10 |
October | 0.489430E+09 | 494.80 | 30-OCT-15:00 | 0.204804E+10 | 1435.25 | 02-OCT-07:10 |
November | 0.502593E+09 | 751.90 | 27-NOV-16:00 | 0.200273E+10 | 1435.25 | 01-NOV-07:10 |
December | 0.496277E+09 | 764.74 | 18-DEC-16:00 | 0.201415E+10 | 1435.25 | 01-DEC-08:09 |
Annual Sum or Average | 0.583391E+10 | 0.243325E+11 | ||||
Minimum of Months | 0.451465E+09 | 465.76 | 0.185366E+10 | 1435.25 | ||
Maximum of Months | 0.520874E+09 | 764.74 | 0.212947E+10 | 1435.25 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.319914E+09 | 467.45 | 02-JAN-16:00 | 0.129621E+10 | 908.57 | 02-JAN-08:09 |
February | 0.286756E+09 | 406.21 | 07-FEB-16:00 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.330706E+09 | 405.98 | 01-MAR-16:00 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.291222E+09 | 296.16 | 13-APR-15:00 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.314545E+09 | 302.25 | 22-MAY-15:00 | 0.132213E+10 | 908.57 | 01-MAY-07:10 |
June | 0.310293E+09 | 293.62 | 01-JUN-15:00 | 0.129819E+10 | 908.57 | 01-JUN-07:10 |
July | 0.293322E+09 | 299.95 | 17-JUL-15:00 | 0.127534E+10 | 908.57 | 03-JUL-07:10 |
August | 0.325186E+09 | 295.80 | 24-AUG-15:00 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.296130E+09 | 302.38 | 22-SEP-15:00 | 0.125111E+10 | 908.57 | 01-SEP-07:10 |
October | 0.310263E+09 | 366.93 | 30-OCT-15:00 | 0.129650E+10 | 908.57 | 02-OCT-07:10 |
November | 0.319586E+09 | 488.37 | 27-NOV-16:00 | 0.126781E+10 | 908.57 | 01-NOV-07:10 |
December | 0.314464E+09 | 490.12 | 18-DEC-16:00 | 0.127504E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.371239E+10 | 0.154036E+11 | ||||
Minimum of Months | 0.286756E+09 | 293.62 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.330706E+09 | 490.12 | 0.134804E+10 | 908.57 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.492721E+09 | 622.20 | 02-JAN-16:00 | 0.204757E+10 | 1435.24 | 02-JAN-08:09 |
February | 0.445724E+09 | 494.25 | 01-FEB-17:00 | 0.185364E+10 | 1435.24 | 01-FEB-08:09 |
March | 0.519202E+09 | 495.55 | 01-MAR-16:00 | 0.212945E+10 | 1435.24 | 01-MAR-08:09 |
April | 0.459858E+09 | 477.08 | 21-APR-07:10 | 0.197725E+10 | 1435.24 | 03-APR-07:10 |
May | 0.498067E+09 | 489.60 | 17-MAY-07:10 | 0.208851E+10 | 1435.24 | 01-MAY-07:10 |
June | 0.491746E+09 | 484.90 | 20-JUN-07:10 | 0.205070E+10 | 1435.24 | 01-JUN-07:10 |
July | 0.465399E+09 | 486.76 | 11-JUL-07:10 | 0.201460E+10 | 1435.24 | 03-JUL-07:10 |
August | 0.514522E+09 | 484.24 | 21-AUG-07:10 | 0.212945E+10 | 1435.24 | 01-AUG-07:10 |
September | 0.465981E+09 | 474.60 | 21-SEP-07:10 | 0.197632E+10 | 1435.24 | 01-SEP-07:10 |
October | 0.484513E+09 | 482.84 | 23-OCT-07:10 | 0.204803E+10 | 1435.24 | 02-OCT-07:10 |
November | 0.490808E+09 | 703.85 | 09-NOV-16:00 | 0.200271E+10 | 1435.24 | 01-NOV-07:10 |
December | 0.482226E+09 | 729.94 | 18-DEC-16:00 | 0.201413E+10 | 1435.24 | 01-DEC-08:09 |
Annual Sum or Average | 0.581077E+10 | 0.243324E+11 | ||||
Minimum of Months | 0.445724E+09 | 474.60 | 0.185364E+10 | 1435.24 | ||
Maximum of Months | 0.519202E+09 | 729.94 | 0.212945E+10 | 1435.24 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.313535E+09 | 369.53 | 02-JAN-16:00 | 0.129620E+10 | 908.57 | 02-JAN-08:09 |
February | 0.282106E+09 | 312.88 | 01-FEB-17:00 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.328126E+09 | 343.65 | 15-MAR-07:10 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.290565E+09 | 312.37 | 21-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.313920E+09 | 357.14 | 17-MAY-07:10 | 0.132212E+10 | 908.57 | 01-MAY-07:10 |
June | 0.309255E+09 | 312.94 | 20-JUN-07:10 | 0.129818E+10 | 908.57 | 01-JUN-07:10 |
July | 0.293476E+09 | 347.46 | 11-JUL-07:10 | 0.127533E+10 | 908.57 | 03-JUL-07:10 |
August | 0.325122E+09 | 350.02 | 21-AUG-07:10 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.295568E+09 | 312.77 | 21-SEP-07:10 | 0.125110E+10 | 908.57 | 01-SEP-07:10 |
October | 0.308321E+09 | 369.76 | 23-OCT-07:10 | 0.129649E+10 | 908.57 | 02-OCT-07:10 |
November | 0.310946E+09 | 422.78 | 09-NOV-16:00 | 0.126780E+10 | 908.57 | 01-NOV-07:10 |
December | 0.306395E+09 | 453.32 | 18-DEC-16:00 | 0.127503E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.367734E+10 | 0.154035E+11 | ||||
Minimum of Months | 0.282106E+09 | 312.37 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.328126E+09 | 453.32 | 0.134804E+10 | 908.57 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.503617E+09 | 706.30 | 02-JAN-16:00 | 0.204758E+10 | 1435.25 | 02-JAN-08:09 |
February | 0.450743E+09 | 494.25 | 01-FEB-17:00 | 0.185366E+10 | 1435.25 | 01-FEB-08:09 |
March | 0.520030E+09 | 583.54 | 01-MAR-16:00 | 0.212947E+10 | 1435.25 | 01-MAR-08:09 |
April | 0.456397E+09 | 467.22 | 21-APR-07:10 | 0.197726E+10 | 1435.25 | 03-APR-07:10 |
May | 0.491654E+09 | 474.00 | 17-MAY-07:10 | 0.208852E+10 | 1435.25 | 01-MAY-07:10 |
June | 0.484086E+09 | 461.24 | 20-JUN-07:10 | 0.205071E+10 | 1435.25 | 01-JUN-07:10 |
July | 0.457713E+09 | 465.54 | 11-JUL-07:10 | 0.201461E+10 | 1435.25 | 03-JUL-07:10 |
August | 0.509559E+09 | 470.09 | 21-AUG-07:10 | 0.212947E+10 | 1435.25 | 01-AUG-07:10 |
September | 0.465145E+09 | 470.35 | 21-SEP-07:10 | 0.197634E+10 | 1435.25 | 01-SEP-07:10 |
October | 0.488358E+09 | 492.09 | 30-OCT-15:00 | 0.204804E+10 | 1435.25 | 02-OCT-07:10 |
November | 0.501051E+09 | 745.46 | 27-NOV-16:00 | 0.200273E+10 | 1435.25 | 01-NOV-07:10 |
December | 0.494693E+09 | 759.05 | 18-DEC-16:00 | 0.201415E+10 | 1435.25 | 01-DEC-08:09 |
Annual Sum or Average | 0.582305E+10 | 0.243325E+11 | ||||
Minimum of Months | 0.450743E+09 | 461.24 | 0.185366E+10 | 1435.25 | ||
Maximum of Months | 0.520030E+09 | 759.05 | 0.212947E+10 | 1435.25 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.319183E+09 | 463.99 | 02-JAN-16:00 | 0.129621E+10 | 908.57 | 02-JAN-08:09 |
February | 0.286197E+09 | 400.57 | 07-FEB-16:00 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.329910E+09 | 400.38 | 01-MAR-16:00 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.290771E+09 | 294.03 | 13-APR-15:00 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.314021E+09 | 300.31 | 22-MAY-15:00 | 0.132213E+10 | 908.57 | 01-MAY-07:10 |
June | 0.309849E+09 | 291.53 | 01-JUN-15:00 | 0.129819E+10 | 908.57 | 01-JUN-07:10 |
July | 0.292863E+09 | 297.91 | 17-JUL-15:00 | 0.127534E+10 | 908.57 | 03-JUL-07:10 |
August | 0.324662E+09 | 293.64 | 24-AUG-15:00 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.295553E+09 | 300.48 | 22-SEP-15:00 | 0.125111E+10 | 908.57 | 01-SEP-07:10 |
October | 0.309648E+09 | 359.93 | 30-OCT-15:00 | 0.129650E+10 | 908.57 | 02-OCT-07:10 |
November | 0.318833E+09 | 485.64 | 27-NOV-16:00 | 0.126781E+10 | 908.57 | 01-NOV-07:10 |
December | 0.313676E+09 | 487.48 | 18-DEC-16:00 | 0.127504E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.370517E+10 | 0.154036E+11 | ||||
Minimum of Months | 0.286197E+09 | 291.53 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.329910E+09 | 487.48 | 0.134804E+10 | 908.57 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.492398E+09 | 610.29 | 02-JAN-16:00 | 0.204757E+10 | 1435.24 | 02-JAN-08:09 |
February | 0.445371E+09 | 494.25 | 01-FEB-17:00 | 0.185364E+10 | 1435.24 | 01-FEB-08:09 |
March | 0.518581E+09 | 494.25 | 01-MAR-17:00 | 0.212945E+10 | 1435.24 | 01-MAR-08:09 |
April | 0.459088E+09 | 473.42 | 21-APR-07:10 | 0.197725E+10 | 1435.24 | 03-APR-07:10 |
May | 0.497024E+09 | 486.61 | 17-MAY-07:10 | 0.208851E+10 | 1435.24 | 01-MAY-07:10 |
June | 0.490787E+09 | 481.71 | 20-JUN-07:10 | 0.205070E+10 | 1435.24 | 01-JUN-07:10 |
July | 0.464349E+09 | 483.65 | 11-JUL-07:10 | 0.201460E+10 | 1435.24 | 03-JUL-07:10 |
August | 0.513524E+09 | 480.97 | 21-AUG-07:10 | 0.212945E+10 | 1435.24 | 01-AUG-07:10 |
September | 0.465209E+09 | 470.79 | 21-SEP-07:10 | 0.197632E+10 | 1435.24 | 01-SEP-07:10 |
October | 0.483721E+09 | 479.37 | 23-OCT-07:10 | 0.204803E+10 | 1435.24 | 02-OCT-07:10 |
November | 0.490774E+09 | 698.53 | 09-NOV-16:00 | 0.200271E+10 | 1435.24 | 01-NOV-07:10 |
December | 0.481716E+09 | 722.55 | 18-DEC-16:00 | 0.201413E+10 | 1435.24 | 01-DEC-08:09 |
Annual Sum or Average | 0.580254E+10 | 0.243324E+11 | ||||
Minimum of Months | 0.445371E+09 | 470.79 | 0.185364E+10 | 1435.24 | ||
Maximum of Months | 0.518581E+09 | 722.55 | 0.212945E+10 | 1435.24 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.313014E+09 | 360.55 | 02-JAN-16:00 | 0.129620E+10 | 908.57 | 02-JAN-08:09 |
February | 0.281789E+09 | 312.88 | 01-FEB-17:00 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.327636E+09 | 312.88 | 01-MAR-17:00 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.290105E+09 | 310.85 | 21-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.313412E+09 | 349.85 | 17-MAY-07:10 | 0.132212E+10 | 908.57 | 01-MAY-07:10 |
June | 0.308735E+09 | 311.42 | 20-JUN-07:10 | 0.129818E+10 | 908.57 | 01-JUN-07:10 |
July | 0.292892E+09 | 312.84 | 11-JUL-07:10 | 0.127533E+10 | 908.57 | 03-JUL-07:10 |
August | 0.324583E+09 | 313.25 | 21-AUG-07:10 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.294908E+09 | 311.27 | 21-SEP-07:10 | 0.125110E+10 | 908.57 | 01-SEP-07:10 |
October | 0.307782E+09 | 362.91 | 23-OCT-07:10 | 0.129649E+10 | 908.57 | 02-OCT-07:10 |
November | 0.310417E+09 | 415.88 | 09-NOV-16:00 | 0.126780E+10 | 908.57 | 01-NOV-07:10 |
December | 0.305716E+09 | 445.97 | 18-DEC-16:00 | 0.127503E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.367099E+10 | 0.154035E+11 | ||||
Minimum of Months | 0.281789E+09 | 310.85 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.327636E+09 | 445.97 | 0.134804E+10 | 908.57 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.504931E+09 | 714.38 | 02-JAN-16:00 | 0.204758E+10 | 1435.25 | 02-JAN-08:09 |
February | 0.451465E+09 | 545.75 | 07-FEB-16:00 | 0.185366E+10 | 1435.25 | 01-FEB-08:09 |
March | 0.520874E+09 | 596.95 | 01-MAR-16:00 | 0.212947E+10 | 1435.25 | 01-MAR-08:09 |
April | 0.457022E+09 | 471.24 | 21-APR-07:10 | 0.197726E+10 | 1435.25 | 03-APR-07:10 |
May | 0.492252E+09 | 477.76 | 17-MAY-07:10 | 0.208852E+10 | 1435.25 | 01-MAY-07:10 |
June | 0.484527E+09 | 465.75 | 20-JUN-07:10 | 0.205071E+10 | 1435.25 | 01-JUN-07:10 |
July | 0.458282E+09 | 469.81 | 11-JUL-07:10 | 0.201461E+10 | 1435.25 | 03-JUL-07:10 |
August | 0.510329E+09 | 474.03 | 21-AUG-07:10 | 0.212947E+10 | 1435.25 | 01-AUG-07:10 |
September | 0.465920E+09 | 474.18 | 21-SEP-07:10 | 0.197634E+10 | 1435.25 | 01-SEP-07:10 |
October | 0.489429E+09 | 494.80 | 30-OCT-15:00 | 0.204804E+10 | 1435.25 | 02-OCT-07:10 |
November | 0.502581E+09 | 751.89 | 27-NOV-16:00 | 0.200273E+10 | 1435.25 | 01-NOV-07:10 |
December | 0.496272E+09 | 764.73 | 18-DEC-16:00 | 0.201415E+10 | 1435.25 | 01-DEC-08:09 |
Annual Sum or Average | 0.583388E+10 | 0.243325E+11 | ||||
Minimum of Months | 0.451465E+09 | 465.75 | 0.185366E+10 | 1435.25 | ||
Maximum of Months | 0.520874E+09 | 764.73 | 0.212947E+10 | 1435.25 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.319914E+09 | 467.44 | 02-JAN-16:00 | 0.129621E+10 | 908.57 | 02-JAN-08:09 |
February | 0.286756E+09 | 406.20 | 07-FEB-16:00 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.330706E+09 | 405.97 | 01-MAR-16:00 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.291222E+09 | 296.16 | 13-APR-15:00 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.314545E+09 | 302.24 | 22-MAY-15:00 | 0.132213E+10 | 908.57 | 01-MAY-07:10 |
June | 0.310293E+09 | 293.61 | 01-JUN-15:00 | 0.129819E+10 | 908.57 | 01-JUN-07:10 |
July | 0.293322E+09 | 299.95 | 17-JUL-15:00 | 0.127534E+10 | 908.57 | 03-JUL-07:10 |
August | 0.325185E+09 | 295.80 | 24-AUG-15:00 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.296130E+09 | 302.37 | 22-SEP-15:00 | 0.125111E+10 | 908.57 | 01-SEP-07:10 |
October | 0.310262E+09 | 366.91 | 30-OCT-15:00 | 0.129650E+10 | 908.57 | 02-OCT-07:10 |
November | 0.319586E+09 | 488.36 | 27-NOV-16:00 | 0.126781E+10 | 908.57 | 01-NOV-07:10 |
December | 0.314464E+09 | 490.11 | 18-DEC-16:00 | 0.127504E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.371238E+10 | 0.154036E+11 | ||||
Minimum of Months | 0.286756E+09 | 293.61 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.330706E+09 | 490.11 | 0.134804E+10 | 908.57 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.492721E+09 | 622.19 | 02-JAN-16:00 | 0.204757E+10 | 1435.24 | 02-JAN-08:09 |
February | 0.445724E+09 | 494.25 | 01-FEB-17:00 | 0.185364E+10 | 1435.24 | 01-FEB-08:09 |
March | 0.519202E+09 | 495.54 | 01-MAR-16:00 | 0.212945E+10 | 1435.24 | 01-MAR-08:09 |
April | 0.459858E+09 | 477.07 | 21-APR-07:10 | 0.197725E+10 | 1435.24 | 03-APR-07:10 |
May | 0.498066E+09 | 489.60 | 17-MAY-07:10 | 0.208851E+10 | 1435.24 | 01-MAY-07:10 |
June | 0.491745E+09 | 484.89 | 20-JUN-07:10 | 0.205070E+10 | 1435.24 | 01-JUN-07:10 |
July | 0.465398E+09 | 486.75 | 11-JUL-07:10 | 0.201460E+10 | 1435.24 | 03-JUL-07:10 |
August | 0.514510E+09 | 484.24 | 21-AUG-07:10 | 0.212945E+10 | 1435.24 | 01-AUG-07:10 |
September | 0.465980E+09 | 474.59 | 21-SEP-07:10 | 0.197632E+10 | 1435.24 | 01-SEP-07:10 |
October | 0.484512E+09 | 482.84 | 23-OCT-07:10 | 0.204803E+10 | 1435.24 | 02-OCT-07:10 |
November | 0.490808E+09 | 703.84 | 09-NOV-16:00 | 0.200271E+10 | 1435.24 | 01-NOV-07:10 |
December | 0.482226E+09 | 729.93 | 18-DEC-16:00 | 0.201413E+10 | 1435.24 | 01-DEC-08:09 |
Annual Sum or Average | 0.581075E+10 | 0.243324E+11 | ||||
Minimum of Months | 0.445724E+09 | 474.59 | 0.185364E+10 | 1435.24 | ||
Maximum of Months | 0.519202E+09 | 729.93 | 0.212945E+10 | 1435.24 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.313535E+09 | 369.53 | 02-JAN-16:00 | 0.129620E+10 | 908.57 | 02-JAN-08:09 |
February | 0.282106E+09 | 312.88 | 01-FEB-17:00 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.328126E+09 | 343.64 | 15-MAR-07:10 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.290565E+09 | 312.37 | 21-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.313919E+09 | 357.13 | 17-MAY-07:10 | 0.132212E+10 | 908.57 | 01-MAY-07:10 |
June | 0.309254E+09 | 312.93 | 20-JUN-07:10 | 0.129818E+10 | 908.57 | 01-JUN-07:10 |
July | 0.293476E+09 | 347.45 | 11-JUL-07:10 | 0.127533E+10 | 908.57 | 03-JUL-07:10 |
August | 0.325121E+09 | 350.01 | 21-AUG-07:10 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.295568E+09 | 312.77 | 21-SEP-07:10 | 0.125110E+10 | 908.57 | 01-SEP-07:10 |
October | 0.308321E+09 | 369.74 | 23-OCT-07:10 | 0.129649E+10 | 908.57 | 02-OCT-07:10 |
November | 0.310946E+09 | 422.77 | 09-NOV-16:00 | 0.126780E+10 | 908.57 | 01-NOV-07:10 |
December | 0.306395E+09 | 453.32 | 18-DEC-16:00 | 0.127503E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.367733E+10 | 0.154035E+11 | ||||
Minimum of Months | 0.282106E+09 | 312.37 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.328126E+09 | 453.32 | 0.134804E+10 | 908.57 |
Report: SpaceGainsMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.471610E+10 | 0.403280E+10 | 0.198672E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.427861E+10 | 0.365805E+10 | 0.179823E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.511242E+10 | 0.434679E+10 | 0.207117E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.453654E+10 | 0.388256E+10 | 0.191625E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.491426E+10 | 0.418979E+10 | 0.202894E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.490054E+10 | 0.416954E+10 | 0.199404E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.455026E+10 | 0.390282E+10 | 0.195094E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.511242E+10 | 0.434679E+10 | 0.207117E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.453654E+10 | 0.388256E+10 | 0.191582E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.471610E+10 | 0.403280E+10 | 0.198694E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.467005E+10 | 0.398554E+10 | 0.194582E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.455026E+10 | 0.390282E+10 | 0.195072E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.565941E+11 | 0.483329E+11 | 0.236167E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.427861E+10 | 0.365805E+10 | 0.179823E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.511242E+10 | 0.434679E+10 | 0.207117E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.471610E+10 | 0.403280E+10 | 0.971303E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.427861E+10 | 0.365805E+10 | 0.879311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.511242E+10 | 0.434679E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.453654E+10 | 0.388256E+10 | 0.937947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.491426E+10 | 0.418979E+10 | 0.990724E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.490054E+10 | 0.416954E+10 | 0.972788E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.455026E+10 | 0.390282E+10 | 0.955663E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.511242E+10 | 0.434679E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.453654E+10 | 0.388256E+10 | 0.937507E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.471610E+10 | 0.403280E+10 | 0.971523E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.467005E+10 | 0.398554E+10 | 0.950025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.455026E+10 | 0.390282E+10 | 0.955443E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.565941E+11 | 0.483329E+11 | 0.115425E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.427861E+10 | 0.365805E+10 | 0.879311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.511242E+10 | 0.434679E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.471610E+10 | 0.403280E+10 | 0.971303E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.427861E+10 | 0.365805E+10 | 0.879311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.511242E+10 | 0.434679E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.453654E+10 | 0.388256E+10 | 0.937947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.491426E+10 | 0.418979E+10 | 0.990724E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.490054E+10 | 0.416954E+10 | 0.972788E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.455026E+10 | 0.390282E+10 | 0.955663E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.511242E+10 | 0.434679E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.453654E+10 | 0.388256E+10 | 0.937507E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.471610E+10 | 0.403280E+10 | 0.971523E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.467005E+10 | 0.398554E+10 | 0.950025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.455026E+10 | 0.390282E+10 | 0.955443E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.565941E+11 | 0.483329E+11 | 0.115425E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.427861E+10 | 0.365805E+10 | 0.879311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.511242E+10 | 0.434679E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.504932E+09 | 0.204758E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13096964.60 | 8120851.67 |
February | 0.901968E+09 | 0.451465E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18464933.54 | 1915213.35 |
March | 0.107774E+10 | 0.520874E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31843200.70 | 2924552.39 |
April | 0.956342E+09 | 0.457022E+09 | 0.197726E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31789207.96 | 527344.38 |
May | 0.103597E+10 | 0.492253E+09 | 0.208852E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34400926.09 | 1641269.78 |
June | 0.103308E+10 | 0.484527E+09 | 0.205071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30708053.43 | 2067872.77 |
July | 0.959235E+09 | 0.458286E+09 | 0.201461E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19007108.52 | 1775611.29 |
August | 0.107774E+10 | 0.510329E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23212508.17 | 3087574.60 |
September | 0.956342E+09 | 0.465921E+09 | 0.197634E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17438101.40 | 1866876.92 |
October | 0.994195E+09 | 0.489430E+09 | 0.204804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14193270.81 | 3461390.54 |
November | 0.984487E+09 | 0.502593E+09 | 0.200273E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11191671.15 | 4262552.78 |
December | 0.959235E+09 | 0.496277E+09 | 0.201415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10586456.25 | 8418900.59 |
Annual Sum or Average | 0.119305E+11 | 0.583391E+10 | 0.243325E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.255932E+09 | 40070011.05 |
Minimum of Months | 0.901968E+09 | 0.451465E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10586456.25 | 527344.38 |
Maximum of Months | 0.107774E+10 | 0.520874E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34400926.09 | 8418900.59 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629407E+09 | 0.319914E+09 | 0.129621E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8507546.61 | 5697848.72 |
February | 0.571020E+09 | 0.286756E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11901700.60 | 1472457.88 |
March | 0.682301E+09 | 0.330706E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20473487.81 | 2165622.74 |
April | 0.605444E+09 | 0.291222E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20807408.71 | 409009.74 |
May | 0.655854E+09 | 0.314545E+09 | 0.132213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23196180.21 | 1059061.83 |
June | 0.654023E+09 | 0.310293E+09 | 0.129819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21003050.98 | 1286626.46 |
July | 0.607275E+09 | 0.293322E+09 | 0.127534E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12944207.80 | 1103703.07 |
August | 0.682301E+09 | 0.325186E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15347496.58 | 2064735.09 |
September | 0.605444E+09 | 0.296130E+09 | 0.125111E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11271061.29 | 1310553.27 |
October | 0.629407E+09 | 0.310263E+09 | 0.129650E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9163687.61 | 2384874.75 |
November | 0.623262E+09 | 0.319586E+09 | 0.126781E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7125456.51 | 2980573.02 |
December | 0.607275E+09 | 0.314464E+09 | 0.127504E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6758201.33 | 5842203.24 |
Annual Sum or Average | 0.755301E+10 | 0.371239E+10 | 0.154036E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.168499E+09 | 27777269.80 |
Minimum of Months | 0.571020E+09 | 0.286756E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6758201.33 | 409009.74 |
Maximum of Months | 0.682301E+09 | 0.330706E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23196180.21 | 5842203.24 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.492721E+09 | 0.204757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11721041.07 | 9274745.22 |
February | 0.901968E+09 | 0.445724E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17242552.17 | 2352546.85 |
March | 0.107774E+10 | 0.519202E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30821414.21 | 3255256.35 |
April | 0.956342E+09 | 0.459858E+09 | 0.197725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31993857.15 | 514922.43 |
May | 0.103597E+10 | 0.498067E+09 | 0.208851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 35310786.21 | 1560496.31 |
June | 0.103308E+10 | 0.491746E+09 | 0.205070E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 32073383.59 | 1862934.92 |
July | 0.959235E+09 | 0.465399E+09 | 0.201460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19924194.85 | 1573081.65 |
August | 0.107774E+10 | 0.514522E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23754551.93 | 2940101.37 |
September | 0.956342E+09 | 0.465981E+09 | 0.197632E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17243470.34 | 1909850.57 |
October | 0.994195E+09 | 0.484513E+09 | 0.204803E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13350184.21 | 3785467.50 |
November | 0.984487E+09 | 0.490808E+09 | 0.200271E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10169733.51 | 4798317.99 |
December | 0.959235E+09 | 0.482226E+09 | 0.201413E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9260061.80 | 9415735.75 |
Annual Sum or Average | 0.119305E+11 | 0.581077E+10 | 0.243324E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.252865E+09 | 43243456.93 |
Minimum of Months | 0.901968E+09 | 0.445724E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9260061.80 | 514922.43 |
Maximum of Months | 0.107774E+10 | 0.519202E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 35310786.21 | 9415735.75 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629366E+09 | 0.313535E+09 | 0.129620E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8515753.20 | 5788355.95 |
February | 0.570983E+09 | 0.282106E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12101857.50 | 1504044.81 |
March | 0.682256E+09 | 0.328126E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20482170.49 | 2479880.52 |
April | 0.605404E+09 | 0.290565E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20494038.94 | 434359.73 |
May | 0.655811E+09 | 0.313920E+09 | 0.132212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23147870.82 | 1115435.88 |
June | 0.653980E+09 | 0.309255E+09 | 0.129818E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20801876.30 | 1374947.65 |
July | 0.607235E+09 | 0.293476E+09 | 0.127533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13134815.49 | 1185570.84 |
August | 0.682256E+09 | 0.325122E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15536749.98 | 2261505.98 |
September | 0.605404E+09 | 0.295568E+09 | 0.125110E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11485966.63 | 1384453.53 |
October | 0.629366E+09 | 0.308321E+09 | 0.129649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9448248.95 | 2482071.34 |
November | 0.623221E+09 | 0.310946E+09 | 0.126780E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7429279.80 | 2983798.77 |
December | 0.607235E+09 | 0.306395E+09 | 0.127503E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6917963.67 | 5845404.47 |
Annual Sum or Average | 0.755252E+10 | 0.367734E+10 | 0.154035E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.169497E+09 | 28839829.47 |
Minimum of Months | 0.570983E+09 | 0.282106E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6917963.67 | 434359.73 |
Maximum of Months | 0.682256E+09 | 0.328126E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23147870.82 | 5845404.47 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.503617E+09 | 0.204758E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7260519.28 | 4356108.60 |
February | 0.901968E+09 | 0.450743E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10217170.79 | 1102504.37 |
March | 0.107774E+10 | 0.520030E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17845050.70 | 1567508.14 |
April | 0.956342E+09 | 0.456397E+09 | 0.197726E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17709090.34 | 280252.04 |
May | 0.103597E+10 | 0.491654E+09 | 0.208852E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18797149.67 | 974962.33 |
June | 0.103308E+10 | 0.484086E+09 | 0.205071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16574630.04 | 1180454.97 |
July | 0.959235E+09 | 0.457713E+09 | 0.201461E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10479436.27 | 1048297.13 |
August | 0.107774E+10 | 0.509559E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12647809.26 | 2021653.65 |
September | 0.956342E+09 | 0.465145E+09 | 0.197634E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9659004.84 | 1089974.23 |
October | 0.994195E+09 | 0.488358E+09 | 0.204804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7992168.84 | 1938689.88 |
November | 0.984487E+09 | 0.501051E+09 | 0.200273E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6248875.57 | 2481417.78 |
December | 0.959235E+09 | 0.494693E+09 | 0.201415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5964753.21 | 4938974.82 |
Annual Sum or Average | 0.119305E+11 | 0.582305E+10 | 0.243325E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.141396E+09 | 22980797.94 |
Minimum of Months | 0.901968E+09 | 0.450743E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5964753.21 | 280252.04 |
Maximum of Months | 0.107774E+10 | 0.520030E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18797149.67 | 4938974.82 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629407E+09 | 0.319183E+09 | 0.129621E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4548362.41 | 3235034.73 |
February | 0.571020E+09 | 0.286197E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6358826.02 | 966352.45 |
March | 0.682301E+09 | 0.329910E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10933196.82 | 1377012.63 |
April | 0.605444E+09 | 0.290771E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11042264.20 | 251990.22 |
May | 0.655854E+09 | 0.314021E+09 | 0.132213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12361429.20 | 664365.05 |
June | 0.654023E+09 | 0.309849E+09 | 0.129819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11191976.64 | 772175.07 |
July | 0.607275E+09 | 0.292863E+09 | 0.127534E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6976300.95 | 699325.21 |
August | 0.682301E+09 | 0.324662E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8147929.58 | 1455335.76 |
September | 0.605444E+09 | 0.295553E+09 | 0.125111E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6029643.29 | 846576.56 |
October | 0.629407E+09 | 0.309648E+09 | 0.129650E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4946147.07 | 1479039.40 |
November | 0.623262E+09 | 0.318833E+09 | 0.126781E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3860736.82 | 1852121.82 |
December | 0.607275E+09 | 0.313676E+09 | 0.127504E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3672362.10 | 3547079.11 |
Annual Sum or Average | 0.755301E+10 | 0.370517E+10 | 0.154036E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 90069175.09 | 17146408.01 |
Minimum of Months | 0.571020E+09 | 0.286197E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3672362.10 | 251990.22 |
Maximum of Months | 0.682301E+09 | 0.329910E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12361429.20 | 3547079.11 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.492398E+09 | 0.204757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.144610E+10 | 0.109173E+09 |
February | 0.901968E+09 | 0.445371E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.151160E+10 | 63614334.51 |
March | 0.107774E+10 | 0.518581E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.219085E+10 | 6723742.98 |
April | 0.956342E+09 | 0.459088E+09 | 0.197725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.213738E+10 | 527680.78 |
May | 0.103597E+10 | 0.497024E+09 | 0.208851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.224126E+10 | 2164238.05 |
June | 0.103308E+10 | 0.490787E+09 | 0.205070E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.232740E+10 | 5079758.30 |
July | 0.959235E+09 | 0.464349E+09 | 0.201460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.142538E+10 | 3462368.59 |
August | 0.107774E+10 | 0.513524E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.188323E+10 | 3995736.21 |
September | 0.956342E+09 | 0.465209E+09 | 0.197632E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.158286E+10 | 3618370.34 |
October | 0.994195E+09 | 0.483721E+09 | 0.204803E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.140240E+10 | 13880923.43 |
November | 0.984487E+09 | 0.490774E+09 | 0.200271E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.142680E+10 | 19681066.61 |
December | 0.959235E+09 | 0.481716E+09 | 0.201413E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.120650E+10 | 96017696.60 |
Annual Sum or Average | 0.119305E+11 | 0.580254E+10 | 0.243324E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.207818E+11 | 0.327939E+09 |
Minimum of Months | 0.901968E+09 | 0.445371E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.120650E+10 | 527680.78 |
Maximum of Months | 0.107774E+10 | 0.518581E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.232740E+10 | 0.109173E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629366E+09 | 0.313014E+09 | 0.129620E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4444004.75 | 3326541.83 |
February | 0.570983E+09 | 0.281789E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6323686.04 | 1021477.03 |
March | 0.682256E+09 | 0.327636E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10756338.02 | 1587762.00 |
April | 0.605404E+09 | 0.290105E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10707946.50 | 279670.42 |
May | 0.655811E+09 | 0.313412E+09 | 0.132212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12198535.40 | 712529.57 |
June | 0.653980E+09 | 0.308735E+09 | 0.129818E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10915076.91 | 825520.29 |
July | 0.607235E+09 | 0.292892E+09 | 0.127533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6909106.11 | 758638.75 |
August | 0.682256E+09 | 0.324583E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8070788.17 | 1565785.93 |
September | 0.605404E+09 | 0.294908E+09 | 0.125110E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6021372.19 | 898475.21 |
October | 0.629366E+09 | 0.307782E+09 | 0.129649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4939546.16 | 1561230.78 |
November | 0.623221E+09 | 0.310417E+09 | 0.126780E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3892099.34 | 1880659.00 |
December | 0.607235E+09 | 0.305716E+09 | 0.127503E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3623698.74 | 3602805.28 |
Annual Sum or Average | 0.755252E+10 | 0.367099E+10 | 0.154035E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 88802198.33 | 18021096.10 |
Minimum of Months | 0.570983E+09 | 0.281789E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3623698.74 | 279670.42 |
Maximum of Months | 0.682256E+09 | 0.327636E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12198535.40 | 3602805.28 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.504931E+09 | 0.204758E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11137930.18 | 7120114.00 |
February | 0.901968E+09 | 0.451465E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15705690.25 | 1719822.79 |
March | 0.107774E+10 | 0.520874E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27228703.14 | 2573970.75 |
April | 0.956342E+09 | 0.457022E+09 | 0.197726E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27196764.42 | 436182.47 |
May | 0.103597E+10 | 0.492252E+09 | 0.208852E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29205539.52 | 1360390.45 |
June | 0.103308E+10 | 0.484527E+09 | 0.205071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 26039648.18 | 1686723.86 |
July | 0.959235E+09 | 0.458282E+09 | 0.201461E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16234096.35 | 1446159.67 |
August | 0.107774E+10 | 0.510329E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19770917.64 | 2728247.20 |
September | 0.956342E+09 | 0.465920E+09 | 0.197634E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15014658.05 | 1546469.30 |
October | 0.994195E+09 | 0.489429E+09 | 0.204804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12271624.26 | 2966052.14 |
November | 0.984487E+09 | 0.502581E+09 | 0.200273E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9624946.55 | 3819226.65 |
December | 0.959235E+09 | 0.496272E+09 | 0.201415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9073045.74 | 7611615.61 |
Annual Sum or Average | 0.119305E+11 | 0.583388E+10 | 0.243325E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.218504E+09 | 35014974.88 |
Minimum of Months | 0.901968E+09 | 0.451465E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9073045.74 | 436182.47 |
Maximum of Months | 0.107774E+10 | 0.520874E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29205539.52 | 7611615.61 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.465148E+09 | 0.319914E+09 | 0.129621E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7208708.66 | 4956494.22 |
February | 0.421807E+09 | 0.286756E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10074047.72 | 1308798.14 |
March | 0.502994E+09 | 0.330706E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17371157.73 | 1884767.45 |
April | 0.447140E+09 | 0.291222E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17677711.07 | 335891.49 |
May | 0.484071E+09 | 0.314545E+09 | 0.132213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19658651.51 | 876775.47 |
June | 0.482240E+09 | 0.310293E+09 | 0.129819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17833794.87 | 1044298.28 |
July | 0.448971E+09 | 0.293322E+09 | 0.127534E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11072357.83 | 898370.88 |
August | 0.502994E+09 | 0.325185E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13039147.77 | 1825883.27 |
September | 0.447140E+09 | 0.296130E+09 | 0.125111E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9627797.21 | 1087621.98 |
October | 0.465148E+09 | 0.310262E+09 | 0.129650E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7863999.35 | 2051955.46 |
November | 0.460569E+09 | 0.319586E+09 | 0.126781E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6115764.84 | 2651373.80 |
December | 0.448971E+09 | 0.314464E+09 | 0.127504E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5778333.49 | 5240000.33 |
Annual Sum or Average | 0.557719E+10 | 0.371238E+10 | 0.154036E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.143321E+09 | 24162230.77 |
Minimum of Months | 0.421807E+09 | 0.286756E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5778333.49 | 335891.49 |
Maximum of Months | 0.502994E+09 | 0.330706E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19658651.51 | 5240000.33 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.492721E+09 | 0.204757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9774858.23 | 8099418.10 |
February | 0.901968E+09 | 0.445724E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14449159.27 | 2105832.82 |
March | 0.107774E+10 | 0.519202E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 26114856.30 | 2848004.69 |
April | 0.956342E+09 | 0.459858E+09 | 0.197725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27385154.24 | 426871.87 |
May | 0.103597E+10 | 0.498066E+09 | 0.208851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30089354.51 | 1300388.29 |
June | 0.103308E+10 | 0.491745E+09 | 0.205070E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27429563.85 | 1507974.81 |
July | 0.959235E+09 | 0.465398E+09 | 0.201460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17174494.83 | 1279338.53 |
August | 0.107774E+10 | 0.514510E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20289308.18 | 2617981.15 |
September | 0.956342E+09 | 0.465980E+09 | 0.197632E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14800474.25 | 1581239.75 |
October | 0.994195E+09 | 0.484512E+09 | 0.204803E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11357857.66 | 3258349.83 |
November | 0.984487E+09 | 0.490808E+09 | 0.200271E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8575354.81 | 4267342.70 |
December | 0.959235E+09 | 0.482226E+09 | 0.201413E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7754096.26 | 8456563.45 |
Annual Sum or Average | 0.119305E+11 | 0.581075E+10 | 0.243324E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.215195E+09 | 37749305.99 |
Minimum of Months | 0.901968E+09 | 0.445724E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7754096.26 | 426871.87 |
Maximum of Months | 0.107774E+10 | 0.519202E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30089354.51 | 8456563.45 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629366E+09 | 0.313535E+09 | 0.129620E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7022778.33 | 5113599.90 |
February | 0.570983E+09 | 0.282106E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10040404.86 | 1365579.85 |
March | 0.682256E+09 | 0.328126E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17081107.71 | 2179862.42 |
April | 0.605404E+09 | 0.290565E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17128087.77 | 365036.49 |
May | 0.655811E+09 | 0.313919E+09 | 0.132212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19371050.84 | 930893.68 |
June | 0.653980E+09 | 0.309254E+09 | 0.129818E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17453788.92 | 1151586.42 |
July | 0.607235E+09 | 0.293476E+09 | 0.127533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10961927.63 | 992013.69 |
August | 0.682256E+09 | 0.325121E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12952449.30 | 2002180.70 |
September | 0.605404E+09 | 0.295568E+09 | 0.125110E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9619438.81 | 1173285.22 |
October | 0.629366E+09 | 0.308321E+09 | 0.129649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7916794.83 | 2181879.26 |
November | 0.623221E+09 | 0.310946E+09 | 0.126780E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6200556.23 | 2700327.37 |
December | 0.607235E+09 | 0.306395E+09 | 0.127503E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5711714.33 | 5322546.83 |
Annual Sum or Average | 0.755252E+10 | 0.367733E+10 | 0.154035E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.141460E+09 | 25478791.82 |
Minimum of Months | 0.570983E+09 | 0.282106E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5711714.33 | 365036.49 |
Maximum of Months | 0.682256E+09 | 0.328126E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19371050.84 | 5322546.83 |
Report: SpaceGainsMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11556527.28 | 9331290.83 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17640499.33 | 1994615.89 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31775820.03 | 2908971.66 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33523596.58 | 419165.67 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36493424.34 | 1507150.95 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32898439.95 | 1816455.60 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20143159.48 | 1382734.13 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23414333.16 | 2826743.36 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17512028.79 | 1623725.68 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13802619.84 | 3405950.43 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10274271.36 | 4675327.50 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9445450.40 | 10200538.43 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.258480E+09 | 42092670.12 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9445450.40 | 419165.67 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36493424.34 | 10200538.43 |
Report: SpaceGainsMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15232969.69 | 11714492.72 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23070016.16 | 2385151.57 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 41067228.65 | 3606700.57 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43119223.35 | 521989.24 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46776236.01 | 1850647.74 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42247545.05 | 2313274.25 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26258588.27 | 1725780.50 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30621859.49 | 3184222.90 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22777203.10 | 1928524.06 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18045071.34 | 4193590.36 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13515633.21 | 5584786.73 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12492152.14 | 12518205.22 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.335224E+09 | 51527365.86 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12492152.14 | 521989.24 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46776236.01 | 12518205.22 |
Report: SpaceGainsMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13624814.92 | 9784903.60 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21399482.10 | 1323725.03 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40030823.56 | 2228639.98 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42084058.47 | 312926.46 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46481294.99 | 1607462.98 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40772776.11 | 2466430.62 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21695436.77 | 1824632.08 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29007062.51 | 2616589.58 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19998542.98 | 2213637.06 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14902721.58 | 4103628.28 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11701228.67 | 4708802.47 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10173304.90 | 10165733.31 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.311872E+09 | 43357111.44 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10173304.90 | 312926.46 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46481294.99 | 10165733.31 |
Report: PeakSpaceGainsMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 6198.29 | 02-JAN-10:09 | 4220.20 | 02-JAN-08:09 | 18185.19 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 6198.29 | 01-FEB-10:09 | 4220.20 | 01-FEB-08:09 | 18185.19 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 6198.29 | 01-MAR-10:09 | 4220.20 | 01-MAR-08:09 | 18185.19 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 6198.29 | 03-APR-09:09 | 4220.20 | 03-APR-07:10 | 18185.19 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 6198.29 | 01-MAY-09:09 | 4220.20 | 01-MAY-07:10 | 18185.19 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 6198.29 | 01-JUN-09:09 | 4220.20 | 01-JUN-07:10 | 18185.19 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 6198.29 | 03-JUL-09:09 | 4220.20 | 03-JUL-07:10 | 18185.19 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 6198.29 | 01-AUG-09:09 | 4220.20 | 01-AUG-07:10 | 18185.19 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 6198.29 | 01-SEP-09:09 | 4220.20 | 01-SEP-07:10 | 18185.19 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 6198.29 | 02-OCT-09:09 | 4220.20 | 02-OCT-07:10 | 18185.19 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 6198.29 | 01-NOV-09:09 | 4220.20 | 01-NOV-07:10 | 18185.19 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6198.29 | 01-DEC-10:09 | 4220.20 | 01-DEC-08:09 | 18185.19 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 6198.29 | 4220.20 | 18185.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 6198.29 | 4220.20 | 18185.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 6198.29 | 02-JAN-10:09 | 4220.20 | 02-JAN-08:09 | 6808.32 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 6198.29 | 01-FEB-10:09 | 4220.20 | 01-FEB-08:09 | 6808.32 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 6198.29 | 01-MAR-10:09 | 4220.20 | 01-MAR-08:09 | 6808.32 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 6198.29 | 03-APR-09:09 | 4220.20 | 03-APR-07:10 | 6808.32 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 6198.29 | 01-MAY-09:09 | 4220.20 | 01-MAY-07:10 | 6808.32 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 6198.29 | 01-JUN-09:09 | 4220.20 | 01-JUN-07:10 | 6808.32 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 6198.29 | 03-JUL-09:09 | 4220.20 | 03-JUL-07:10 | 6808.32 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 6198.29 | 01-AUG-09:09 | 4220.20 | 01-AUG-07:10 | 6808.32 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 6198.29 | 01-SEP-09:09 | 4220.20 | 01-SEP-07:10 | 6808.32 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 6198.29 | 02-OCT-09:09 | 4220.20 | 02-OCT-07:10 | 6808.32 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 6198.29 | 01-NOV-09:09 | 4220.20 | 01-NOV-07:10 | 6808.32 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6198.29 | 01-DEC-10:09 | 4220.20 | 01-DEC-08:09 | 6808.32 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 6198.29 | 4220.20 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 6198.29 | 4220.20 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 6198.29 | 02-JAN-10:09 | 4220.20 | 02-JAN-08:09 | 6808.32 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 6198.29 | 01-FEB-10:09 | 4220.20 | 01-FEB-08:09 | 6808.32 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 6198.29 | 01-MAR-10:09 | 4220.20 | 01-MAR-08:09 | 6808.32 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 6198.29 | 03-APR-09:09 | 4220.20 | 03-APR-07:10 | 6808.32 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 6198.29 | 01-MAY-09:09 | 4220.20 | 01-MAY-07:10 | 6808.32 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 6198.29 | 01-JUN-09:09 | 4220.20 | 01-JUN-07:10 | 6808.32 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 6198.29 | 03-JUL-09:09 | 4220.20 | 03-JUL-07:10 | 6808.32 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 6198.29 | 01-AUG-09:09 | 4220.20 | 01-AUG-07:10 | 6808.32 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 6198.29 | 01-SEP-09:09 | 4220.20 | 01-SEP-07:10 | 6808.32 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 6198.29 | 02-OCT-09:09 | 4220.20 | 02-OCT-07:10 | 6808.32 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 6198.29 | 01-NOV-09:09 | 4220.20 | 01-NOV-07:10 | 6808.32 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6198.29 | 01-DEC-10:09 | 4220.20 | 01-DEC-08:09 | 6808.32 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 6198.29 | 4220.20 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 6198.29 | 4220.20 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 714.39 | 02-JAN-16:00 | 1435.25 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 51.45 | 15-JAN-13:00 | 112.91 | 07-JAN-05:00 |
February | 1306.65 | 01-FEB-10:09 | 545.77 | 07-FEB-16:00 | 1435.25 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 93.34 | 19-FEB-15:00 | 13.18 | 20-FEB-06:47 |
March | 1306.65 | 01-MAR-10:09 | 596.97 | 01-MAR-16:00 | 1435.25 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 157.13 | 19-MAR-16:00 | 22.80 | 03-MAR-05:35 |
April | 1306.65 | 03-APR-09:09 | 471.25 | 21-APR-07:10 | 1435.25 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 81.37 | 30-APR-15:36 | 8.39 | 22-APR-03:00 |
May | 1306.65 | 01-MAY-09:09 | 477.76 | 17-MAY-07:10 | 1435.25 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 111.80 | 07-MAY-15:00 | 44.90 | 08-MAY-22:00 |
June | 1306.65 | 01-JUN-09:09 | 465.76 | 20-JUN-07:10 | 1435.25 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 104.60 | 18-JUN-14:05 | 52.27 | 20-JUN-23:00 |
July | 1306.65 | 03-JUL-09:09 | 469.82 | 11-JUL-07:10 | 1435.25 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 90.63 | 04-JUL-14:10 | 25.61 | 02-JUL-14:00 |
August | 1306.65 | 01-AUG-09:09 | 474.04 | 21-AUG-07:10 | 1435.25 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 109.90 | 06-AUG-13:00 | 49.03 | 20-AUG-11:00 |
September | 1306.65 | 01-SEP-09:09 | 474.18 | 21-SEP-07:10 | 1435.25 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 108.60 | 10-SEP-15:00 | 25.80 | 15-SEP-22:00 |
October | 1306.65 | 02-OCT-09:09 | 494.80 | 30-OCT-15:00 | 1435.25 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 100.99 | 29-OCT-13:50 | 22.62 | 22-OCT-18:00 |
November | 1306.65 | 01-NOV-09:09 | 751.90 | 27-NOV-16:00 | 1435.25 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 54.13 | 11-NOV-16:00 | 23.27 | 25-NOV-05:00 |
December | 1306.65 | 01-DEC-10:09 | 764.74 | 18-DEC-16:00 | 1435.25 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 41.52 | 31-DEC-10:00 | 43.09 | 21-DEC-05:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 465.76 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 41.52 | 8.39 | |||||
Maximum of Months | 1306.65 | 764.74 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 157.13 | 112.91 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.22 | 02-JAN-10:09 | 467.45 | 02-JAN-16:00 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 35.06 | 15-JAN-13:00 | 75.44 | 07-JAN-05:00 |
February | 827.22 | 01-FEB-10:09 | 406.21 | 07-FEB-16:00 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 62.97 | 19-FEB-15:00 | 13.27 | 19-FEB-07:00 |
March | 827.22 | 01-MAR-10:09 | 405.98 | 01-MAR-16:00 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 107.53 | 19-MAR-15:37 | 15.24 | 03-MAR-05:35 |
April | 827.22 | 03-APR-09:09 | 296.16 | 13-APR-15:00 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 55.36 | 30-APR-15:38 | 8.46 | 23-APR-07:10 |
May | 827.22 | 01-MAY-09:09 | 302.25 | 22-MAY-15:00 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 77.76 | 07-MAY-14:36 | 29.98 | 08-MAY-22:00 |
June | 827.22 | 01-JUN-09:09 | 293.62 | 01-JUN-15:00 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 73.67 | 18-JUN-14:08 | 34.26 | 20-JUN-23:00 |
July | 827.22 | 03-JUL-09:09 | 299.95 | 17-JUL-15:00 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 63.61 | 04-JUL-14:10 | 15.06 | 02-JUL-14:00 |
August | 827.22 | 01-AUG-09:09 | 295.80 | 24-AUG-15:00 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 73.36 | 06-AUG-13:00 | 34.74 | 20-AUG-11:00 |
September | 827.22 | 01-SEP-09:09 | 302.38 | 22-SEP-15:00 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 73.75 | 10-SEP-14:50 | 17.02 | 15-SEP-22:00 |
October | 827.22 | 02-OCT-09:09 | 366.93 | 30-OCT-15:00 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 71.20 | 29-OCT-13:50 | 15.06 | 22-OCT-18:00 |
November | 827.22 | 01-NOV-09:09 | 488.37 | 27-NOV-16:00 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 35.89 | 11-NOV-16:00 | 16.83 | 26-NOV-10:00 |
December | 827.22 | 01-DEC-10:09 | 490.12 | 18-DEC-16:00 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 25.55 | 24-DEC-15:00 | 28.69 | 21-DEC-05:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.22 | 293.62 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 25.55 | 8.46 | |||||
Maximum of Months | 827.22 | 490.12 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 107.53 | 75.44 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 622.20 | 02-JAN-16:00 | 1435.24 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 41.61 | 15-JAN-12:58 | 116.82 | 07-JAN-05:00 |
February | 1306.65 | 01-FEB-10:09 | 494.25 | 01-FEB-17:00 | 1435.24 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 88.97 | 19-FEB-15:00 | 14.96 | 20-FEB-06:47 |
March | 1306.65 | 01-MAR-10:09 | 495.55 | 01-MAR-16:00 | 1435.24 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 157.12 | 19-MAR-16:00 | 23.12 | 03-MAR-05:35 |
April | 1306.65 | 03-APR-09:09 | 477.08 | 21-APR-07:10 | 1435.24 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 81.71 | 30-APR-15:38 | 8.26 | 22-APR-03:00 |
May | 1306.65 | 01-MAY-09:09 | 489.60 | 17-MAY-07:10 | 1435.24 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 114.75 | 07-MAY-14:36 | 44.40 | 08-MAY-22:00 |
June | 1306.65 | 01-JUN-09:09 | 484.90 | 20-JUN-07:10 | 1435.24 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 108.11 | 18-JUN-14:08 | 50.54 | 20-JUN-23:00 |
July | 1306.65 | 03-JUL-09:09 | 486.76 | 11-JUL-07:10 | 1435.24 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 92.41 | 04-JUL-14:10 | 18.65 | 02-JUL-13:20 |
August | 1306.65 | 01-AUG-09:09 | 484.24 | 21-AUG-07:10 | 1435.24 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 114.57 | 06-AUG-13:00 | 48.60 | 20-AUG-11:00 |
September | 1306.65 | 01-SEP-09:09 | 474.60 | 21-SEP-07:10 | 1435.24 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 106.45 | 10-SEP-14:46 | 26.12 | 15-SEP-22:00 |
October | 1306.65 | 02-OCT-09:09 | 482.84 | 23-OCT-07:10 | 1435.24 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 96.13 | 29-OCT-13:08 | 23.06 | 22-OCT-18:00 |
November | 1306.65 | 01-NOV-09:09 | 703.85 | 09-NOV-16:00 | 1435.24 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 47.89 | 11-NOV-16:00 | 25.25 | 26-NOV-10:00 |
December | 1306.65 | 01-DEC-10:09 | 729.94 | 18-DEC-16:00 | 1435.24 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 35.02 | 24-DEC-15:00 | 44.03 | 21-DEC-05:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 474.60 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 35.02 | 8.26 | |||||
Maximum of Months | 1306.65 | 729.94 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 157.12 | 116.82 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.17 | 02-JAN-10:09 | 369.53 | 02-JAN-16:00 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 36.40 | 15-JAN-13:00 | 75.59 | 07-JAN-05:00 |
February | 827.17 | 01-FEB-10:09 | 312.88 | 01-FEB-17:00 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 60.97 | 19-FEB-15:00 | 9.11 | 20-FEB-06:47 |
March | 827.17 | 01-MAR-10:09 | 343.65 | 15-MAR-07:10 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 104.75 | 19-MAR-16:00 | 15.45 | 03-MAR-05:35 |
April | 827.17 | 03-APR-09:09 | 312.37 | 21-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 52.04 | 30-APR-15:36 | 7.00 | 09-APR-16:40 |
May | 827.17 | 01-MAY-09:09 | 357.14 | 17-MAY-07:10 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 77.23 | 21-MAY-11:40 | 29.91 | 08-MAY-22:00 |
June | 827.17 | 01-JUN-09:09 | 312.94 | 20-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 71.37 | 18-JUN-14:05 | 35.10 | 20-JUN-23:00 |
July | 827.17 | 03-JUL-09:09 | 347.46 | 11-JUL-07:10 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 61.50 | 04-JUL-14:10 | 15.00 | 02-JUL-14:00 |
August | 827.17 | 01-AUG-09:09 | 350.02 | 21-AUG-07:10 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 80.56 | 06-AUG-12:03 | 32.55 | 20-AUG-11:00 |
September | 827.17 | 01-SEP-09:09 | 312.77 | 21-SEP-07:10 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 70.16 | 10-SEP-14:55 | 17.10 | 15-SEP-22:00 |
October | 827.17 | 02-OCT-09:09 | 369.76 | 23-OCT-07:10 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 70.60 | 29-OCT-13:48 | 15.32 | 22-OCT-18:00 |
November | 827.17 | 01-NOV-09:09 | 422.78 | 09-NOV-16:00 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 34.15 | 11-NOV-16:00 | 15.55 | 25-NOV-05:00 |
December | 827.17 | 01-DEC-10:09 | 453.32 | 18-DEC-16:00 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 29.87 | 31-DEC-10:00 | 28.83 | 21-DEC-05:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.17 | 312.37 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 29.87 | 7.00 | |||||
Maximum of Months | 827.17 | 453.32 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 104.75 | 75.59 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 706.30 | 02-JAN-16:00 | 1435.25 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 30.25 | 15-JAN-13:10 | 72.17 | 07-JAN-05:00 |
February | 1306.65 | 01-FEB-10:09 | 494.25 | 01-FEB-17:00 | 1435.25 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 53.06 | 19-FEB-15:00 | 7.52 | 19-FEB-07:00 |
March | 1306.65 | 01-MAR-10:09 | 583.54 | 01-MAR-16:00 | 1435.25 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 93.50 | 19-MAR-16:00 | 13.07 | 03-MAR-05:00 |
April | 1306.65 | 03-APR-09:09 | 467.22 | 21-APR-07:10 | 1435.25 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.01 | 30-APR-15:40 | 5.32 | 22-APR-03:00 |
May | 1306.65 | 01-MAY-09:09 | 474.00 | 17-MAY-07:10 | 1435.25 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 60.99 | 07-MAY-14:38 | 26.00 | 08-MAY-22:00 |
June | 1306.65 | 01-JUN-09:09 | 461.24 | 20-JUN-07:10 | 1435.25 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 57.19 | 18-JUN-14:08 | 28.88 | 20-JUN-23:00 |
July | 1306.65 | 03-JUL-09:09 | 465.54 | 11-JUL-07:10 | 1435.25 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 49.03 | 04-JUL-14:10 | 10.09 | 02-JUL-13:30 |
August | 1306.65 | 01-AUG-09:09 | 470.09 | 21-AUG-07:10 | 1435.25 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 60.49 | 06-AUG-13:00 | 27.67 | 20-AUG-11:00 |
September | 1306.65 | 01-SEP-09:09 | 470.35 | 21-SEP-07:10 | 1435.25 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 66.10 | 10-SEP-15:00 | 17.21 | 15-SEP-22:00 |
October | 1306.65 | 02-OCT-09:09 | 492.09 | 30-OCT-15:00 | 1435.25 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 60.19 | 29-OCT-13:10 | 12.33 | 23-OCT-03:00 |
November | 1306.65 | 01-NOV-09:09 | 745.46 | 27-NOV-16:00 | 1435.25 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 31.73 | 11-NOV-15:50 | 13.66 | 25-NOV-05:00 |
December | 1306.65 | 01-DEC-10:09 | 759.05 | 18-DEC-16:00 | 1435.25 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 23.79 | 24-DEC-15:00 | 26.09 | 21-DEC-05:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 461.24 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 23.79 | 5.32 | |||||
Maximum of Months | 1306.65 | 759.05 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 93.50 | 72.17 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.22 | 02-JAN-10:09 | 463.99 | 02-JAN-16:00 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 17.54 | 15-JAN-13:10 | 50.26 | 07-JAN-05:00 |
February | 827.22 | 01-FEB-10:09 | 400.57 | 07-FEB-16:00 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 34.80 | 20-FEB-15:58 | 7.56 | 19-FEB-07:00 |
March | 827.22 | 01-MAR-10:09 | 400.38 | 01-MAR-16:00 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 57.67 | 19-MAR-16:00 | 9.37 | 14-MAR-22:00 |
April | 827.22 | 03-APR-09:09 | 294.03 | 13-APR-15:00 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 29.67 | 30-APR-15:40 | 4.66 | 23-APR-07:10 |
May | 827.22 | 01-MAY-09:09 | 300.31 | 22-MAY-15:00 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 41.45 | 07-MAY-14:40 | 17.87 | 08-MAY-22:00 |
June | 827.22 | 01-JUN-09:09 | 291.53 | 01-JUN-15:00 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 39.33 | 18-JUN-14:10 | 19.10 | 20-JUN-23:00 |
July | 827.22 | 03-JUL-09:09 | 297.91 | 17-JUL-15:00 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 33.55 | 04-JUL-14:10 | 6.68 | 02-JUL-13:30 |
August | 827.22 | 01-AUG-09:09 | 293.64 | 24-AUG-15:00 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.75 | 06-AUG-13:00 | 19.51 | 20-AUG-10:50 |
September | 827.22 | 01-SEP-09:09 | 300.48 | 22-SEP-15:00 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 40.86 | 10-SEP-15:00 | 12.04 | 15-SEP-22:00 |
October | 827.22 | 02-OCT-09:09 | 359.93 | 30-OCT-15:00 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 36.67 | 29-OCT-13:50 | 8.36 | 23-OCT-03:00 |
November | 827.22 | 01-NOV-09:09 | 485.64 | 27-NOV-16:00 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.61 | 11-NOV-15:50 | 9.62 | 26-NOV-10:00 |
December | 827.22 | 01-DEC-10:09 | 487.48 | 18-DEC-16:00 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 15.07 | 31-DEC-13:00 | 17.66 | 21-DEC-05:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.22 | 291.53 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 15.07 | 4.66 | |||||
Maximum of Months | 827.22 | 487.48 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 57.67 | 50.26 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 610.29 | 02-JAN-16:00 | 1435.24 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 9246.17 | 04-JAN-12:02 | 5086.65 | 23-JAN-07:03 |
February | 1306.65 | 01-FEB-10:09 | 494.25 | 01-FEB-17:00 | 1435.24 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 9060.96 | 24-FEB-17:02 | 3262.51 | 01-FEB-07:03 |
March | 1306.65 | 01-MAR-10:09 | 494.25 | 01-MAR-17:00 | 1435.24 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 11124.20 | 21-MAR-11:02 | 782.51 | 15-MAR-06:10 |
April | 1306.65 | 03-APR-09:09 | 473.42 | 21-APR-07:10 | 1435.24 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 11561.67 | 11-APR-16:02 | 198.04 | 14-APR-16:00 |
May | 1306.65 | 01-MAY-09:09 | 486.61 | 17-MAY-07:10 | 1435.24 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 13576.55 | 05-MAY-11:01 | 187.23 | 09-MAY-05:03 |
June | 1306.65 | 01-JUN-09:09 | 481.71 | 20-JUN-07:10 | 1435.24 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 12191.69 | 12-JUN-16:02 | 751.21 | 21-JUN-06:05 |
July | 1306.65 | 03-JUL-09:09 | 483.65 | 11-JUL-07:10 | 1435.24 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 9834.41 | 20-JUL-16:02 | 336.60 | 13-JUL-05:03 |
August | 1306.65 | 01-AUG-09:09 | 480.97 | 21-AUG-07:10 | 1435.24 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10904.04 | 15-AUG-11:02 | 411.44 | 21-AUG-11:10 |
September | 1306.65 | 01-SEP-09:09 | 470.79 | 21-SEP-07:10 | 1435.24 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 9521.74 | 13-SEP-16:02 | 1212.12 | 15-SEP-17:00 |
October | 1306.65 | 02-OCT-09:09 | 479.37 | 23-OCT-07:10 | 1435.24 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 8929.99 | 04-OCT-11:02 | 1243.09 | 30-OCT-17:00 |
November | 1306.65 | 01-NOV-09:09 | 698.53 | 09-NOV-16:00 | 1435.24 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 8538.15 | 10-NOV-12:02 | 2383.39 | 27-NOV-07:05 |
December | 1306.65 | 01-DEC-10:09 | 722.55 | 18-DEC-16:00 | 1435.24 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 7677.38 | 08-DEC-12:02 | 5462.66 | 21-DEC-07:03 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 470.79 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 7677.38 | 187.23 | |||||
Maximum of Months | 1306.65 | 722.55 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 13576.55 | 5462.66 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.17 | 02-JAN-10:09 | 360.55 | 02-JAN-16:00 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 18.84 | 15-JAN-13:10 | 50.41 | 07-JAN-05:00 |
February | 827.17 | 01-FEB-10:09 | 312.88 | 01-FEB-17:00 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 31.03 | 20-FEB-15:56 | 5.74 | 19-FEB-07:00 |
March | 827.17 | 01-MAR-10:09 | 312.88 | 01-MAR-17:00 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 56.06 | 19-MAR-16:00 | 9.31 | 03-MAR-05:00 |
April | 827.17 | 03-APR-09:09 | 310.85 | 21-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 28.20 | 30-APR-15:34 | 4.06 | 22-APR-03:00 |
May | 827.17 | 01-MAY-09:09 | 349.85 | 17-MAY-07:10 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 40.28 | 21-MAY-11:33 | 17.99 | 08-MAY-22:00 |
June | 827.17 | 01-JUN-09:09 | 311.42 | 20-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.85 | 18-JUN-14:08 | 19.57 | 20-JUN-23:00 |
July | 827.17 | 03-JUL-09:09 | 312.84 | 11-JUL-07:10 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 32.19 | 04-JUL-14:10 | 6.25 | 02-JUL-13:30 |
August | 827.17 | 01-AUG-09:09 | 313.25 | 21-AUG-07:10 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 40.58 | 06-AUG-12:13 | 18.56 | 20-AUG-11:00 |
September | 827.17 | 01-SEP-09:09 | 311.27 | 21-SEP-07:10 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 37.63 | 10-SEP-14:55 | 12.33 | 15-SEP-22:00 |
October | 827.17 | 02-OCT-09:09 | 362.91 | 23-OCT-07:10 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 36.16 | 29-OCT-13:50 | 8.49 | 22-OCT-18:00 |
November | 827.17 | 01-NOV-09:09 | 415.88 | 09-NOV-16:00 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 17.27 | 11-NOV-16:00 | 9.35 | 25-NOV-05:00 |
December | 827.17 | 01-DEC-10:09 | 445.97 | 18-DEC-16:00 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 14.80 | 31-DEC-12:20 | 17.72 | 21-DEC-05:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.17 | 310.85 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 14.80 | 4.06 | |||||
Maximum of Months | 827.17 | 445.97 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 56.06 | 50.41 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 714.38 | 02-JAN-16:00 | 1435.25 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 46.34 | 15-JAN-13:10 | 106.51 | 07-JAN-05:00 |
February | 1306.65 | 01-FEB-10:09 | 545.75 | 07-FEB-16:00 | 1435.25 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 79.56 | 19-FEB-15:00 | 11.56 | 19-FEB-07:00 |
March | 1306.65 | 01-MAR-10:09 | 596.95 | 01-MAR-16:00 | 1435.25 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 139.63 | 19-MAR-16:00 | 20.65 | 03-MAR-05:35 |
April | 1306.65 | 03-APR-09:09 | 471.24 | 21-APR-07:10 | 1435.25 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 68.14 | 30-APR-15:40 | 7.82 | 22-APR-03:00 |
May | 1306.65 | 01-MAY-09:09 | 477.76 | 17-MAY-07:10 | 1435.25 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 94.63 | 07-MAY-14:36 | 37.28 | 08-MAY-22:00 |
June | 1306.65 | 01-JUN-09:09 | 465.75 | 20-JUN-07:10 | 1435.25 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 88.59 | 18-JUN-14:08 | 41.77 | 20-JUN-23:00 |
July | 1306.65 | 03-JUL-09:09 | 469.81 | 11-JUL-07:10 | 1435.25 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 75.80 | 04-JUL-14:10 | 17.28 | 02-JUL-13:43 |
August | 1306.65 | 01-AUG-09:09 | 474.03 | 21-AUG-07:10 | 1435.25 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 92.82 | 06-AUG-12:20 | 42.05 | 20-AUG-11:00 |
September | 1306.65 | 01-SEP-09:09 | 474.18 | 21-SEP-07:10 | 1435.25 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 99.83 | 10-SEP-15:00 | 23.53 | 15-SEP-22:00 |
October | 1306.65 | 02-OCT-09:09 | 494.80 | 30-OCT-15:00 | 1435.25 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 88.55 | 29-OCT-13:10 | 18.89 | 22-OCT-18:00 |
November | 1306.65 | 01-NOV-09:09 | 751.89 | 27-NOV-16:00 | 1435.25 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.25 | 11-NOV-16:00 | 20.67 | 25-NOV-05:00 |
December | 1306.65 | 01-DEC-10:09 | 764.73 | 18-DEC-16:00 | 1435.25 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 36.26 | 24-DEC-15:00 | 39.06 | 21-DEC-05:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 465.75 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 36.26 | 7.82 | |||||
Maximum of Months | 1306.65 | 764.73 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 139.63 | 106.51 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 805.43 | 02-JAN-08:09 | 467.44 | 02-JAN-16:00 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 27.85 | 15-JAN-13:10 | 70.92 | 07-JAN-05:00 |
February | 805.43 | 01-FEB-08:09 | 406.20 | 07-FEB-16:00 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 51.27 | 19-FEB-15:00 | 11.76 | 19-FEB-07:00 |
March | 805.43 | 01-MAR-08:09 | 405.97 | 01-MAR-16:00 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 90.70 | 19-MAR-16:00 | 13.78 | 03-MAR-05:35 |
April | 805.43 | 03-APR-07:10 | 296.16 | 13-APR-15:00 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 46.52 | 30-APR-15:40 | 7.44 | 23-APR-07:10 |
May | 805.43 | 01-MAY-07:10 | 302.24 | 22-MAY-15:00 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 65.16 | 07-MAY-14:40 | 24.88 | 08-MAY-22:00 |
June | 805.43 | 01-JUN-07:10 | 293.61 | 01-JUN-15:00 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 61.72 | 18-JUN-14:10 | 27.36 | 20-JUN-23:00 |
July | 805.43 | 03-JUL-07:10 | 299.95 | 17-JUL-15:00 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 53.45 | 04-JUL-14:10 | 10.38 | 02-JUL-13:43 |
August | 805.43 | 01-AUG-07:10 | 295.80 | 24-AUG-15:00 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 61.38 | 06-AUG-13:00 | 29.74 | 20-AUG-11:00 |
September | 805.43 | 01-SEP-07:10 | 302.37 | 22-SEP-15:00 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 64.85 | 10-SEP-15:00 | 15.43 | 15-SEP-22:00 |
October | 805.43 | 02-OCT-07:10 | 366.91 | 30-OCT-15:00 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 57.78 | 29-OCT-13:50 | 12.60 | 22-OCT-18:00 |
November | 805.43 | 01-NOV-07:10 | 488.36 | 27-NOV-16:00 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 31.54 | 11-NOV-15:50 | 14.24 | 26-NOV-10:00 |
December | 805.43 | 01-DEC-08:09 | 490.11 | 18-DEC-16:00 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 23.69 | 31-DEC-13:00 | 25.96 | 21-DEC-05:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 805.43 | 293.61 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 23.69 | 7.44 | |||||
Maximum of Months | 805.43 | 490.11 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 90.70 | 70.92 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 622.19 | 02-JAN-16:00 | 1435.24 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 34.09 | 15-JAN-13:07 | 109.82 | 07-JAN-05:00 |
February | 1306.65 | 01-FEB-10:09 | 494.25 | 01-FEB-17:00 | 1435.24 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 71.74 | 19-FEB-15:00 | 13.22 | 19-FEB-07:00 |
March | 1306.65 | 01-MAR-10:09 | 495.54 | 01-MAR-16:00 | 1435.24 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 131.30 | 19-MAR-16:00 | 20.91 | 03-MAR-05:35 |
April | 1306.65 | 03-APR-09:09 | 477.07 | 21-APR-07:10 | 1435.24 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 68.56 | 30-APR-15:40 | 7.71 | 22-APR-03:00 |
May | 1306.65 | 01-MAY-09:09 | 489.60 | 17-MAY-07:10 | 1435.24 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 96.71 | 07-MAY-15:00 | 36.81 | 08-MAY-22:00 |
June | 1306.65 | 01-JUN-09:09 | 484.89 | 20-JUN-07:10 | 1435.24 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 90.26 | 18-JUN-14:50 | 40.39 | 20-JUN-23:00 |
July | 1306.65 | 03-JUL-09:09 | 486.75 | 11-JUL-07:10 | 1435.24 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 80.02 | 04-JUL-14:10 | 11.75 | 02-JUL-13:43 |
August | 1306.65 | 01-AUG-09:09 | 484.24 | 21-AUG-07:10 | 1435.24 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 96.57 | 06-AUG-13:00 | 41.67 | 20-AUG-11:00 |
September | 1306.65 | 01-SEP-09:09 | 474.59 | 21-SEP-07:10 | 1435.24 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 96.15 | 10-SEP-15:00 | 23.79 | 15-SEP-22:00 |
October | 1306.65 | 02-OCT-09:09 | 482.84 | 23-OCT-07:10 | 1435.24 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 80.69 | 29-OCT-13:08 | 19.27 | 22-OCT-18:00 |
November | 1306.65 | 01-NOV-09:09 | 703.84 | 09-NOV-16:00 | 1435.24 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.91 | 11-NOV-15:50 | 21.37 | 26-NOV-10:00 |
December | 1306.65 | 01-DEC-10:09 | 729.93 | 18-DEC-16:00 | 1435.24 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 30.35 | 31-DEC-12:56 | 39.82 | 21-DEC-05:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 474.59 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 30.35 | 7.71 | |||||
Maximum of Months | 1306.65 | 729.93 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 131.30 | 109.82 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.17 | 02-JAN-10:09 | 369.53 | 02-JAN-16:00 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 30.24 | 15-JAN-13:10 | 71.28 | 07-JAN-05:00 |
February | 827.17 | 01-FEB-10:09 | 312.88 | 01-FEB-17:00 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 47.83 | 19-FEB-15:00 | 8.19 | 19-FEB-07:00 |
March | 827.17 | 01-MAR-10:09 | 343.64 | 15-MAR-07:10 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 87.48 | 19-MAR-16:00 | 14.01 | 03-MAR-05:35 |
April | 827.17 | 03-APR-09:09 | 312.37 | 21-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 43.92 | 30-APR-15:34 | 5.64 | 22-APR-03:00 |
May | 827.17 | 01-MAY-09:09 | 357.13 | 17-MAY-07:10 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 64.37 | 21-MAY-11:33 | 25.12 | 08-MAY-22:00 |
June | 827.17 | 01-JUN-09:09 | 312.93 | 20-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 59.18 | 18-JUN-14:05 | 28.15 | 20-JUN-23:00 |
July | 827.17 | 03-JUL-09:09 | 347.45 | 11-JUL-07:10 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 50.27 | 04-JUL-14:10 | 10.29 | 02-JUL-13:43 |
August | 827.17 | 01-AUG-09:09 | 350.01 | 21-AUG-07:10 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 66.46 | 06-AUG-12:13 | 27.94 | 20-AUG-11:00 |
September | 827.17 | 01-SEP-09:09 | 312.77 | 21-SEP-07:10 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.65 | 10-SEP-14:55 | 15.80 | 15-SEP-22:00 |
October | 827.17 | 02-OCT-09:09 | 369.74 | 23-OCT-07:10 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 56.80 | 29-OCT-13:50 | 12.91 | 22-OCT-18:00 |
November | 827.17 | 01-NOV-09:09 | 422.77 | 09-NOV-16:00 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 27.87 | 11-NOV-15:50 | 13.82 | 25-NOV-05:00 |
December | 827.17 | 01-DEC-10:09 | 453.32 | 18-DEC-16:00 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 24.39 | 31-DEC-12:20 | 26.13 | 21-DEC-05:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.17 | 312.37 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 24.39 | 5.64 | |||||
Maximum of Months | 827.17 | 453.32 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 87.48 | 71.28 |
Report: PeakSpaceGainsMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52.12 | 15-JAN-12:53 | 149.52 | 07-JAN-05:00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 100.07 | 19-FEB-15:00 | 16.74 | 20-FEB-06:53 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 176.89 | 19-MAR-16:00 | 26.79 | 03-MAR-05:05 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85.95 | 30-APR-16:00 | 9.66 | 22-APR-03:00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 125.29 | 07-MAY-15:00 | 43.49 | 08-MAY-22:00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 113.96 | 18-JUN-14:30 | 41.95 | 20-JUN-23:00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 100.92 | 04-JUL-13:53 | 14.50 | 19-JUL-21:20 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 119.21 | 06-AUG-13:00 | 44.05 | 20-AUG-11:00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 124.17 | 10-SEP-15:00 | 29.92 | 15-SEP-22:00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 109.77 | 29-OCT-12:52 | 23.79 | 23-OCT-04:53 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 53.47 | 11-NOV-16:00 | 27.84 | 25-NOV-05:05 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.87 | 24-DEC-15:00 | 54.01 | 21-DEC-05:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.87 | 9.66 | ||
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 176.89 | 149.52 |
Report: PeakSpaceGainsMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 69.46 | 15-JAN-12:53 | 181.49 | 07-JAN-05:00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 129.79 | 19-FEB-15:00 | 21.07 | 20-FEB-06:53 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 225.91 | 19-MAR-16:00 | 32.51 | 03-MAR-05:45 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 109.06 | 30-APR-16:00 | 11.73 | 22-APR-03:00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 159.20 | 07-MAY-15:00 | 56.60 | 08-MAY-22:00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 145.79 | 18-JUN-14:30 | 52.87 | 20-JUN-23:00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 132.31 | 04-JUL-13:53 | 17.75 | 19-JUL-21:20 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 157.18 | 06-AUG-13:00 | 52.68 | 20-AUG-11:00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 159.86 | 10-SEP-15:00 | 35.32 | 15-SEP-22:00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 142.55 | 29-OCT-12:52 | 29.95 | 23-OCT-05:00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 70.29 | 11-NOV-16:00 | 34.67 | 25-NOV-05:00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 56.42 | 24-DEC-15:00 | 67.18 | 21-DEC-05:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 56.42 | 11.73 | ||
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 225.91 | 181.49 |
Report: PeakSpaceGainsMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43.18 | 15-JAN-12:43 | 134.75 | 07-JAN-05:00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 99.30 | 19-FEB-15:00 | 17.82 | 20-FEB-06:55 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 175.36 | 19-MAR-16:00 | 28.09 | 03-MAR-05:55 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 91.03 | 09-APR-15:00 | 7.26 | 13-APR-04:55 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 156.29 | 21-MAY-11:40 | 53.95 | 08-MAY-22:00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 114.81 | 18-JUN-13:52 | 64.96 | 20-JUN-23:00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 91.00 | 04-JUL-13:50 | 52.68 | 02-JUL-14:00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 163.04 | 06-AUG-12:23 | 65.79 | 20-AUG-11:00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 96.46 | 10-SEP-15:00 | 46.17 | 03-SEP-16:10 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 96.07 | 29-OCT-12:52 | 37.91 | 09-OCT-17:03 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.52 | 11-NOV-16:00 | 33.81 | 26-NOV-10:00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.84 | 31-DEC-10:00 | 59.16 | 21-DEC-05:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43.18 | 7.26 | ||
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 175.36 | 134.75 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 41161.81 | 23-JAN-05:03 | 0.00 | 1875.67 | 17622.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 40778.87 | 24-FEB-05:03 | 0.00 | 1875.67 | 17622.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 40620.36 | 07-MAR-05:03 | 0.00 | 1875.67 | 17622.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 40042.37 | 05-APR-04:03 | 0.00 | 1875.67 | 17622.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 40123.28 | 11-MAY-04:03 | 0.00 | 1875.67 | 17622.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 40255.77 | 21-JUN-04:03 | 0.00 | 1875.67 | 17622.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 40519.33 | 18-JUL-04:03 | 0.00 | 1875.67 | 17622.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 40969.10 | 22-AUG-04:03 | 0.00 | 1875.67 | 17622.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 40451.66 | 19-SEP-04:03 | 0.00 | 1875.67 | 17622.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 41067.90 | 23-OCT-04:02 | 0.00 | 2344.59 | 22028.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 41734.95 | 27-NOV-05:02 | 0.00 | 2344.59 | 22028.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 41018.99 | 27-DEC-05:03 | 0.00 | 1875.67 | 17622.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 40042.37 | 0.00 | 1875.67 | 17622.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 41734.95 | 0.00 | 2344.59 | 22028.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 10040.70 | 31-JAN-14:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.72 | 0.00 |
February | 11256.59 | 21-FEB-14:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.39 | 0.00 |
March | 11429.71 | 20-MAR-13:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.05 | 0.00 |
April | 10686.63 | 11-APR-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.34 | 0.00 |
May | 11441.34 | 05-MAY-13:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.64 | 0.00 |
June | 11150.65 | 16-JUN-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.14 | 0.00 |
July | 9789.86 | 14-JUL-14:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.73 | 0.00 |
August | 10468.75 | 14-AUG-13:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.57 | 0.00 |
September | 10364.43 | 06-SEP-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.65 | 0.00 |
October | 9817.99 | 02-OCT-13:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.19 | 0.00 |
November | 9635.98 | 22-NOV-13:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.70 | 0.00 |
December | 9930.78 | 26-DEC-13:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.64 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 9635.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.70 | 0.00 | |
Maximum of Months | 11441.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.14 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 4771.39 | 02-JAN-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.25 |
February | 4699.60 | 21-FEB-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.03 | 0.00 |
March | 4531.70 | 20-MAR-15:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.48 | 0.00 |
April | 4214.60 | 17-APR-15:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.13 | 0.00 |
May | 4819.98 | 30-MAY-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 4710.37 | 12-JUN-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.78 | 0.00 |
July | 4317.42 | 31-JUL-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.81 |
August | 4274.40 | 14-AUG-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.60 | 0.00 |
September | 4781.42 | 05-SEP-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 | 0.00 |
October | 4593.70 | 10-OCT-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.13 |
November | 4441.95 | 13-NOV-13:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.11 | 0.00 |
December | 4407.24 | 26-DEC-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.03 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 4214.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 4819.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.48 | 4.03 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5035.06 | 02-JAN-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.19 |
February | 4970.65 | 21-FEB-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.49 | 0.00 |
March | 4743.20 | 20-MAR-12:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.96 | 0.00 |
April | 4598.23 | 17-APR-15:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.75 | 0.00 |
May | 5342.44 | 30-MAY-12:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.34 | 0.00 |
June | 5123.48 | 12-JUN-12:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.35 | 0.00 |
July | 4713.15 | 17-JUL-12:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.93 | 0.00 |
August | 4786.87 | 14-AUG-12:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.87 | 0.00 |
September | 4954.43 | 05-SEP-12:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.65 | 0.00 |
October | 4822.67 | 10-OCT-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.47 |
November | 4909.34 | 13-NOV-13:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.74 | 0.00 |
December | 4841.42 | 26-DEC-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.07 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 4598.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 5342.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.96 | 3.07 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 33009.14 | 02-JAN-05:04 | 0.00 | 2344.59 | 12210.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 29449.27 | 22-FEB-05:03 | 0.00 | 1875.67 | 9768.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 28926.30 | 21-MAR-04:03 | 0.00 | 1875.67 | 9768.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 28770.64 | 04-APR-04:03 | 0.00 | 1875.67 | 9768.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 29570.98 | 22-MAY-04:04 | 0.00 | 2344.59 | 12210.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 29029.51 | 20-JUN-04:03 | 0.00 | 1875.67 | 9768.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 28809.38 | 06-JUL-04:03 | 0.00 | 1875.67 | 9768.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 29397.15 | 21-AUG-04:02 | 0.00 | 2344.59 | 12210.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 28816.03 | 06-SEP-04:03 | 0.00 | 1875.67 | 9768.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 29742.49 | 23-OCT-04:02 | 0.00 | 2344.59 | 12210.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 30334.94 | 27-NOV-05:02 | 0.00 | 2344.59 | 12210.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 29301.38 | 18-DEC-05:02 | 0.00 | 2344.59 | 12210.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 28770.64 | 0.00 | 1875.67 | 9768.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 33009.14 | 0.00 | 2344.59 | 12210.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 33320.18 | 17-JAN-05:02 | 0.00 | 2344.59 | 12210.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 32786.22 | 06-FEB-05:02 | 0.00 | 2344.59 | 12210.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 32315.81 | 06-MAR-05:02 | 0.00 | 2344.59 | 12210.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 32575.64 | 10-APR-04:02 | 0.00 | 2344.59 | 12210.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 31757.92 | 02-MAY-04:03 | 0.00 | 1875.67 | 9768.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 32552.68 | 26-JUN-04:03 | 0.00 | 1875.67 | 9768.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 32305.15 | 17-JUL-04:02 | 0.00 | 2344.59 | 12210.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 31769.61 | 28-AUG-04:02 | 0.00 | 2344.59 | 12210.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 31749.16 | 25-SEP-04:02 | 0.00 | 2344.59 | 12210.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 33358.84 | 23-OCT-04:02 | 0.00 | 2344.59 | 12210.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 32946.02 | 06-NOV-05:02 | 0.00 | 2344.59 | 12210.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 32870.41 | 18-DEC-05:02 | 0.00 | 2344.59 | 12210.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 31749.16 | 0.00 | 1875.67 | 9768.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 33358.84 | 0.00 | 2344.59 | 12210.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 10098.15 | 02-JAN-05:02 | 0.00 | 494.26 | 2574.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.44 |
February | 9826.64 | 21-FEB-05:02 | 0.00 | 494.26 | 2574.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 11482.86 | 19-MAR-15:32 | 401.76 | 141.44 | 2870.49 | 0.00 | 0.00 | 0.00 | 0.00 | 145.45 | 0.00 |
April | 11510.19 | 30-APR-12:53 | 267.84 | 94.29 | 1913.66 | 0.00 | 0.00 | 0.00 | 0.00 | 29.96 | 0.00 |
May | 12084.93 | 29-MAY-13:02 | 267.84 | 94.29 | 1913.66 | 0.00 | 0.00 | 0.00 | 0.00 | 38.51 | 0.00 |
June | 12168.21 | 11-JUN-12:32 | 267.84 | 94.29 | 1913.66 | 0.00 | 0.00 | 0.00 | 0.00 | 70.04 | 0.00 |
July | 11622.61 | 04-JUL-16:02 | 334.80 | 117.87 | 2392.08 | 0.00 | 0.00 | 0.00 | 0.00 | 59.62 | 0.00 |
August | 11656.20 | 13-AUG-13:32 | 267.84 | 94.29 | 1913.66 | 0.00 | 0.00 | 0.00 | 0.00 | 54.90 | 0.00 |
September | 11554.55 | 04-SEP-13:23 | 267.84 | 94.29 | 1913.66 | 0.00 | 0.00 | 0.00 | 0.00 | 42.86 | 0.00 |
October | 10226.59 | 29-OCT-13:43 | 267.84 | 94.29 | 1913.66 | 0.00 | 0.00 | 0.00 | 0.00 | 81.16 | 0.00 |
November | 8958.46 | 13-NOV-05:02 | 0.00 | 494.26 | 2574.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.27 |
December | 7934.83 | 25-DEC-15:32 | 334.80 | 117.87 | 2392.08 | 0.00 | 0.00 | 0.00 | 0.00 | 18.90 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 7934.83 | 0.00 | 94.29 | 1913.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 12168.21 | 401.76 | 494.26 | 2870.49 | 0.00 | 0.00 | 0.00 | 0.00 | 145.45 | 3.44 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 9632.50 | 16-JAN-11:02 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 4.36 | 0.00 |
February | 10781.19 | 20-FEB-09:32 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 6.98 | 0.00 |
March | 10772.10 | 05-MAR-10:02 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 15.73 | 0.00 |
April | 10807.32 | 23-APR-09:53 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 12.15 | 0.00 |
May | 10813.46 | 14-MAY-09:02 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 14.36 | 0.00 |
June | 10743.82 | 11-JUN-08:32 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 22.38 | 0.00 |
July | 8860.91 | 30-JUL-14:53 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 35.64 | 0.00 |
August | 10808.00 | 13-AUG-09:32 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 22.71 | 0.00 |
September | 10802.23 | 10-SEP-10:02 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 18.26 | 0.00 |
October | 8647.51 | 29-OCT-11:43 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 48.35 | 0.00 |
November | 9174.43 | 05-NOV-11:13 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 21.79 | 0.00 |
December | 7878.82 | 03-DEC-11:23 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 12.45 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 7878.82 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 4.36 | 0.00 | |
Maximum of Months | 10813.46 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 48.35 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 12160.90 | 29-JAN-12:13 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 13.06 | 0.00 |
February | 12121.78 | 20-FEB-11:32 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 27.73 | 0.00 |
March | 11804.16 | 19-MAR-12:53 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 89.66 | 0.00 |
April | 11229.47 | 02-APR-12:23 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 22.67 | 0.00 |
May | 11480.43 | 29-MAY-13:02 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 40.57 | 0.00 |
June | 11298.58 | 11-JUN-12:32 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 77.48 | 0.00 |
July | 10877.72 | 30-JUL-14:53 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 53.95 | 0.00 |
August | 11180.69 | 13-AUG-13:32 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 56.58 | 0.00 |
September | 11397.10 | 04-SEP-13:23 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 41.49 | 0.00 |
October | 11922.40 | 29-OCT-11:43 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 62.26 | 0.00 |
November | 12111.14 | 11-NOV-12:32 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 19.08 | 0.00 |
December | 12406.59 | 25-DEC-15:32 | 334.80 | 117.87 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 12.20 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 10877.72 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 12.20 | 0.00 | |
Maximum of Months | 12406.59 | 334.80 | 117.87 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 89.66 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 12269.78 | 16-JAN-15:42 | 211.94 | 74.61 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 12.06 | 0.00 |
February | 12228.38 | 26-FEB-15:52 | 211.94 | 74.61 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 51.57 | 0.00 |
March | 12608.20 | 19-MAR-15:32 | 254.33 | 89.54 | 1817.13 | 0.00 | 0.00 | 0.00 | 0.00 | 87.30 | 0.00 |
April | 12558.80 | 02-APR-17:42 | 0.00 | 81.33 | 1222.09 | 0.00 | 0.00 | 0.00 | 0.00 | 20.57 | 0.00 |
May | 12572.85 | 07-MAY-17:12 | 0.00 | 74.61 | 1222.09 | 0.00 | 0.00 | 0.00 | 0.00 | 22.99 | 0.00 |
June | 12587.91 | 18-JUN-17:22 | 0.00 | 74.61 | 1222.09 | 0.00 | 0.00 | 0.00 | 0.00 | 13.80 | 0.00 |
July | 12203.82 | 04-JUL-16:42 | 211.94 | 74.61 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 26.61 | 0.00 |
August | 12204.30 | 27-AUG-16:12 | 211.94 | 74.61 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 36.02 | 0.00 |
September | 12680.33 | 10-SEP-16:42 | 211.94 | 74.61 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 1.07 | 0.00 |
October | 11986.45 | 29-OCT-15:43 | 169.55 | 59.69 | 1211.42 | 0.00 | 0.00 | 0.00 | 0.00 | 24.98 | 0.00 |
November | 12034.32 | 11-NOV-14:32 | 169.55 | 59.69 | 1211.42 | 0.00 | 0.00 | 0.00 | 0.00 | 21.01 | 0.00 |
December | 12750.16 | 25-DEC-15:32 | 211.94 | 74.61 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 9.73 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 11986.45 | 0.00 | 59.69 | 1211.42 | 0.00 | 0.00 | 0.00 | 0.00 | 1.07 | 0.00 | |
Maximum of Months | 12750.16 | 254.33 | 89.54 | 1817.13 | 0.00 | 0.00 | 0.00 | 0.00 | 87.30 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 7442.58 | 02-JAN-07:03 | 803.52 | 640.90 | 1913.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.01 |
February | 7772.76 | 27-FEB-05:02 | 0.00 | 494.26 | 2574.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.75 |
March | 7781.11 | 20-MAR-04:02 | 0.00 | 494.26 | 2574.02 | 0.00 | 0.00 | 0.00 | 0.00 | 6.52 | 0.00 |
April | 7859.93 | 17-APR-04:02 | 0.00 | 494.26 | 2574.02 | 0.00 | 0.00 | 0.00 | 0.00 | 2.09 | 0.00 |
May | 9961.16 | 29-MAY-13:02 | 267.84 | 94.29 | 1913.66 | 0.00 | 0.00 | 0.00 | 0.00 | 21.90 | 0.00 |
June | 10084.60 | 11-JUN-12:32 | 267.84 | 94.29 | 1913.66 | 0.00 | 0.00 | 0.00 | 0.00 | 39.96 | 0.00 |
July | 8023.99 | 03-JUL-04:02 | 0.00 | 494.26 | 2574.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.59 |
August | 8450.78 | 14-AUG-04:02 | 0.00 | 494.26 | 2574.02 | 0.00 | 0.00 | 0.00 | 0.00 | 1.61 | 0.00 |
September | 7828.46 | 05-SEP-04:02 | 0.00 | 494.26 | 2574.02 | 0.00 | 0.00 | 0.00 | 0.00 | 1.56 | 0.00 |
October | 7961.35 | 02-OCT-04:02 | 0.00 | 494.26 | 2574.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 |
November | 7891.40 | 13-NOV-05:02 | 0.00 | 494.26 | 2574.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.58 |
December | 6722.37 | 18-DEC-05:02 | 0.00 | 494.26 | 2574.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.53 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 6722.37 | 0.00 | 94.29 | 1913.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 10084.60 | 803.52 | 640.90 | 2574.02 | 0.00 | 0.00 | 0.00 | 0.00 | 39.96 | 1.75 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 6994.62 | 16-JAN-11:23 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 2.88 | 0.00 |
February | 9579.12 | 20-FEB-09:53 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 5.68 | 0.00 |
March | 9486.98 | 05-MAR-10:02 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 9.37 | 0.00 |
April | 9488.98 | 16-APR-10:32 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 11.24 | 0.00 |
May | 9559.21 | 29-MAY-07:42 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 3.73 | 0.00 |
June | 9504.96 | 11-JUN-08:32 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 12.90 | 0.00 |
July | 7485.08 | 31-JUL-04:02 | 0.00 | 312.91 | 1629.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.34 |
August | 9525.79 | 13-AUG-09:32 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 13.11 | 0.00 |
September | 9573.00 | 04-SEP-10:32 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 5.77 | 0.00 |
October | 7910.12 | 08-OCT-08:32 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 2.69 | 0.00 |
November | 7361.96 | 13-NOV-05:02 | 0.00 | 312.91 | 1629.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.89 |
December | 7346.24 | 31-DEC-09:32 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 4.98 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 6994.62 | 0.00 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 9579.12 | 169.56 | 312.91 | 1629.47 | 0.00 | 0.00 | 0.00 | 0.00 | 13.11 | 1.34 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 10488.27 | 04-JAN-13:00 | 687.71 | 424.37 | 1275.77 | 0.00 | 0.00 | 0.00 | 0.00 | 7474.80 | 0.00 |
February | 10397.80 | 21-FEB-13:00 | 687.71 | 424.37 | 1275.77 | 0.00 | 0.00 | 0.00 | 0.00 | 7593.55 | 0.00 |
March | 10313.72 | 21-MAR-12:00 | 687.71 | 424.37 | 1275.77 | 0.00 | 0.00 | 0.00 | 0.00 | 8792.96 | 0.00 |
April | 9876.50 | 18-APR-12:00 | 687.71 | 424.37 | 1275.77 | 0.00 | 0.00 | 0.00 | 0.00 | 8511.71 | 0.00 |
May | 10676.37 | 05-MAY-12:00 | 687.71 | 424.37 | 1275.77 | 0.00 | 0.00 | 0.00 | 0.00 | 10576.40 | 0.00 |
June | 10218.27 | 16-JUN-12:00 | 687.71 | 424.37 | 1275.77 | 0.00 | 0.00 | 0.00 | 0.00 | 9118.55 | 0.00 |
July | 9402.73 | 26-JUL-17:00 | 401.76 | 258.62 | 797.35 | 0.00 | 0.00 | 0.00 | 0.00 | 8129.08 | 0.00 |
August | 9876.02 | 15-AUG-12:00 | 687.71 | 424.37 | 1275.77 | 0.00 | 0.00 | 0.00 | 0.00 | 8197.27 | 0.00 |
September | 9701.24 | 05-SEP-12:00 | 687.71 | 424.37 | 1275.77 | 0.00 | 0.00 | 0.00 | 0.00 | 7661.32 | 0.00 |
October | 9887.90 | 29-OCT-11:43 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 35.85 | 0.00 |
November | 9975.28 | 19-NOV-11:32 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 11.41 | 0.00 |
December | 10387.11 | 25-DEC-13:22 | 334.80 | 117.87 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 6.09 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 9402.73 | 267.84 | 94.29 | 797.35 | 0.00 | 0.00 | 0.00 | 0.00 | 6.09 | 0.00 | |
Maximum of Months | 10676.37 | 687.71 | 424.37 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 10576.40 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 10091.91 | 08-JAN-15:53 | 169.55 | 59.69 | 1211.42 | 0.00 | 0.00 | 0.00 | 0.00 | 11.46 | 0.00 |
February | 10550.84 | 20-FEB-15:52 | 211.94 | 74.61 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 25.78 | 0.00 |
March | 10295.54 | 19-MAR-15:32 | 254.33 | 89.54 | 1817.13 | 0.00 | 0.00 | 0.00 | 0.00 | 49.49 | 0.00 |
April | 10409.25 | 02-APR-17:42 | 0.00 | 80.40 | 1222.09 | 0.00 | 0.00 | 0.00 | 0.00 | 12.48 | 0.00 |
May | 10363.16 | 07-MAY-17:12 | 0.00 | 74.61 | 1222.09 | 0.00 | 0.00 | 0.00 | 0.00 | 13.59 | 0.00 |
June | 10405.92 | 18-JUN-17:22 | 0.00 | 74.61 | 1222.09 | 0.00 | 0.00 | 0.00 | 0.00 | 8.41 | 0.00 |
July | 9660.40 | 04-JUL-16:02 | 211.94 | 74.61 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 21.29 | 0.00 |
August | 9685.47 | 27-AUG-16:12 | 211.94 | 74.61 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 19.89 | 0.00 |
September | 10450.37 | 10-SEP-16:42 | 211.94 | 74.61 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 1.24 | 0.00 |
October | 8926.15 | 29-OCT-15:43 | 169.55 | 59.69 | 1211.42 | 0.00 | 0.00 | 0.00 | 0.00 | 13.89 | 0.00 |
November | 9017.85 | 19-NOV-16:53 | 169.55 | 59.69 | 1211.42 | 0.00 | 0.00 | 0.00 | 0.00 | 5.37 | 0.00 |
December | 10375.07 | 25-DEC-15:22 | 211.94 | 74.61 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 5.90 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 8926.15 | 0.00 | 59.69 | 1211.42 | 0.00 | 0.00 | 0.00 | 0.00 | 1.24 | 0.00 | |
Maximum of Months | 10550.84 | 254.33 | 89.54 | 1817.13 | 0.00 | 0.00 | 0.00 | 0.00 | 49.49 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 8054.73 | 02-JAN-05:02 | 0.00 | 494.26 | 2574.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.13 |
February | 7995.71 | 27-FEB-05:02 | 0.00 | 494.26 | 2574.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.86 |
March | 7801.42 | 13-MAR-04:02 | 0.00 | 494.26 | 2574.02 | 0.00 | 0.00 | 0.00 | 0.00 | 1.30 | 0.00 |
April | 8125.47 | 10-APR-04:02 | 0.00 | 494.26 | 2574.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.16 |
May | 9875.83 | 29-MAY-13:02 | 267.84 | 94.29 | 1913.66 | 0.00 | 0.00 | 0.00 | 0.00 | 33.58 | 0.00 |
June | 10041.86 | 11-JUN-12:32 | 267.84 | 94.29 | 1913.66 | 0.00 | 0.00 | 0.00 | 0.00 | 61.33 | 0.00 |
July | 8869.91 | 04-JUL-15:22 | 334.80 | 117.87 | 2392.08 | 0.00 | 0.00 | 0.00 | 0.00 | 59.49 | 0.00 |
August | 9205.07 | 13-AUG-13:32 | 267.84 | 94.29 | 1913.66 | 0.00 | 0.00 | 0.00 | 0.00 | 48.77 | 0.00 |
September | 7971.73 | 25-SEP-04:02 | 0.00 | 494.26 | 2574.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.32 | 0.00 |
October | 8228.97 | 02-OCT-04:02 | 0.00 | 494.26 | 2574.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.54 |
November | 8099.14 | 24-NOV-05:02 | 0.00 | 494.26 | 2574.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.44 |
December | 8062.79 | 26-DEC-05:02 | 0.00 | 494.26 | 2574.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.16 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 7801.42 | 0.00 | 94.29 | 1913.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 10041.86 | 334.80 | 494.26 | 2574.02 | 0.00 | 0.00 | 0.00 | 0.00 | 61.33 | 14.16 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 7452.53 | 16-JAN-11:23 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 4.46 | 0.00 |
February | 10133.02 | 20-FEB-09:23 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 5.09 | 0.00 |
March | 10109.69 | 05-MAR-10:02 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 13.81 | 0.00 |
April | 10122.94 | 23-APR-09:53 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 10.98 | 0.00 |
May | 10153.48 | 14-MAY-09:02 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 12.52 | 0.00 |
June | 10109.38 | 11-JUN-08:32 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 19.28 | 0.00 |
July | 7308.09 | 31-JUL-04:02 | 0.00 | 312.91 | 1629.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.86 |
August | 10124.66 | 13-AUG-09:32 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 19.88 | 0.00 |
September | 10104.15 | 10-SEP-10:02 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 15.89 | 0.00 |
October | 9386.50 | 08-OCT-08:32 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 4.10 | 0.00 |
November | 7177.46 | 13-NOV-07:03 | 508.69 | 268.66 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 1.15 | 0.00 |
December | 8850.62 | 31-DEC-09:32 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 7.66 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 7177.46 | 0.00 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 10153.48 | 508.69 | 312.91 | 1629.47 | 0.00 | 0.00 | 0.00 | 0.00 | 19.88 | 1.86 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 10246.29 | 08-JAN-13:53 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 17.45 | 0.00 |
February | 10046.81 | 20-FEB-11:23 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 23.20 | 0.00 |
March | 9751.65 | 19-MAR-12:53 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 78.09 | 0.00 |
April | 7915.61 | 10-APR-04:02 | 0.00 | 494.26 | 2574.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 |
May | 9332.31 | 29-MAY-13:02 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 35.60 | 0.00 |
June | 7816.49 | 13-JUN-04:02 | 0.00 | 494.26 | 2574.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.91 | 0.00 |
July | 7814.39 | 17-JUL-04:02 | 0.00 | 494.26 | 2574.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.20 |
August | 7658.84 | 25-AUG-05:03 | 535.68 | 395.41 | 2551.53 | 0.00 | 0.00 | 0.00 | 0.00 | 1.15 | 0.00 |
September | 8674.52 | 04-SEP-13:23 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 37.24 | 0.00 |
October | 9941.03 | 29-OCT-11:43 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 54.20 | 0.00 |
November | 10034.34 | 19-NOV-11:32 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 17.33 | 0.00 |
December | 10443.88 | 31-DEC-12:52 | 334.80 | 117.87 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 22.01 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 7658.84 | 0.00 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 10443.88 | 535.68 | 494.26 | 2574.00 | 0.00 | 0.00 | 0.00 | 0.00 | 78.09 | 3.20 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 11127.74 | 29-JAN-16:02 | 211.94 | 74.61 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 17.20 | 0.00 |
February | 10849.19 | 20-FEB-16:02 | 254.33 | 89.54 | 1817.13 | 0.00 | 0.00 | 0.00 | 0.00 | 39.65 | 0.00 |
March | 11052.60 | 19-MAR-15:32 | 254.33 | 89.54 | 1817.13 | 0.00 | 0.00 | 0.00 | 0.00 | 75.31 | 0.00 |
April | 11092.82 | 02-APR-16:22 | 254.33 | 89.54 | 1817.13 | 0.00 | 0.00 | 0.00 | 0.00 | 35.25 | 0.00 |
May | 10938.65 | 07-MAY-17:12 | 0.00 | 74.61 | 1222.09 | 0.00 | 0.00 | 0.00 | 0.00 | 21.12 | 0.00 |
June | 11005.09 | 18-JUN-17:22 | 0.00 | 74.61 | 1222.09 | 0.00 | 0.00 | 0.00 | 0.00 | 13.13 | 0.00 |
July | 10751.58 | 04-JUL-16:02 | 211.94 | 74.61 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 32.71 | 0.00 |
August | 10680.05 | 27-AUG-16:12 | 211.94 | 74.61 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 30.86 | 0.00 |
September | 11154.29 | 10-SEP-16:42 | 211.94 | 74.61 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 1.83 | 0.00 |
October | 9835.94 | 29-OCT-15:43 | 169.55 | 59.69 | 1211.42 | 0.00 | 0.00 | 0.00 | 0.00 | 21.41 | 0.00 |
November | 9644.58 | 11-NOV-15:02 | 169.55 | 59.69 | 1211.42 | 0.00 | 0.00 | 0.00 | 0.00 | 18.50 | 0.00 |
December | 11122.58 | 25-DEC-15:22 | 211.94 | 74.61 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 8.84 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 9644.58 | 0.00 | 59.69 | 1211.42 | 0.00 | 0.00 | 0.00 | 0.00 | 1.83 | 0.00 | |
Maximum of Months | 11154.29 | 254.33 | 89.54 | 1817.13 | 0.00 | 0.00 | 0.00 | 0.00 | 75.31 | 0.00 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | NATURALGAS:FACILITY [J] | NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | |
January | 0.156434E+12 | 138455.04 | 04-JAN-13:00 | 0.737222E+10 | 8617.92 | 05-JAN-12:09 |
February | 0.145739E+12 | 145689.60 | 13-FEB-14:00 | 0.665591E+10 | 8614.69 | 07-FEB-12:09 |
March | 0.172101E+12 | 149091.61 | 20-MAR-15:09 | 0.755697E+10 | 8599.91 | 08-MAR-12:09 |
April | 0.166615E+12 | 148171.98 | 11-APR-15:50 | 0.699336E+10 | 8578.77 | 04-APR-11:09 |
May | 0.181768E+12 | 157001.67 | 04-MAY-12:00 | 0.727864E+10 | 8558.69 | 02-MAY-11:09 |
June | 0.181883E+12 | 162130.67 | 13-JUN-15:20 | 0.708088E+10 | 8534.44 | 05-JUN-11:09 |
July | 0.158311E+12 | 141999.93 | 17-JUL-12:00 | 0.700525E+10 | 8526.46 | 24-JUL-11:09 |
August | 0.174362E+12 | 149806.90 | 14-AUG-12:00 | 0.734945E+10 | 8537.64 | 28-AUG-11:09 |
September | 0.160689E+12 | 147064.36 | 05-SEP-12:00 | 0.693618E+10 | 8556.53 | 25-SEP-11:20 |
October | 0.160704E+12 | 143179.54 | 16-OCT-12:00 | 0.723731E+10 | 8581.56 | 30-OCT-11:20 |
November | 0.155817E+12 | 143804.51 | 13-NOV-13:00 | 0.712261E+10 | 8600.72 | 29-NOV-12:09 |
December | 0.151676E+12 | 136639.28 | 12-DEC-13:00 | 0.726908E+10 | 8614.36 | 27-DEC-12:20 |
Annual Sum or Average | 0.196610E+13 | 0.858578E+11 | ||||
Minimum of Months | 0.145739E+12 | 136639.28 | 0.665591E+10 | 8526.46 | ||
Maximum of Months | 0.181883E+12 | 162130.67 | 0.755697E+10 | 8617.92 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [J] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [J] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [J] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 0.169888E+11 | 0.446840E+10 | 0.593559E+11 | 0.979694E+09 | 0.942059E+10 | 1312252.65 | 0.00 | 0.637861E+11 | 0.00 | 0.00 | 0.143303E+10 | 0.00 | 0.00 |
February | 0.153704E+11 | 0.392615E+10 | 0.537310E+11 | 0.886636E+09 | 0.901404E+10 | 1186778.30 | 0.00 | 0.614911E+11 | 0.00 | 0.00 | 0.131872E+10 | 0.00 | 0.00 |
March | 0.181343E+11 | 0.411161E+10 | 0.617796E+11 | 0.102602E+10 | 0.104594E+11 | 1343621.24 | 0.00 | 0.750638E+11 | 0.00 | 0.00 | 0.152474E+10 | 0.00 | 0.00 |
April | 0.161414E+11 | 0.380860E+10 | 0.572952E+11 | 0.943609E+09 | 0.969832E+10 | 1267813.82 | 0.00 | 0.772721E+11 | 0.00 | 0.00 | 0.145492E+10 | 0.00 | 0.00 |
May | 0.174231E+11 | 0.381151E+10 | 0.605677E+11 | 0.100278E+10 | 0.104222E+11 | 1327936.95 | 0.00 | 0.870089E+11 | 0.00 | 0.00 | 0.153020E+10 | 0.00 | 0.00 |
June | 0.172937E+11 | 0.364255E+10 | 0.594895E+11 | 0.987112E+09 | 0.110169E+11 | 1296568.36 | 0.00 | 0.879597E+11 | 0.00 | 0.00 | 0.149199E+10 | 0.00 | 0.00 |
July | 0.162372E+11 | 0.382877E+10 | 0.583622E+11 | 0.959149E+09 | 0.902317E+10 | 1299182.41 | 0.00 | 0.684621E+11 | 0.00 | 0.00 | 0.143748E+10 | 0.00 | 0.00 |
August | 0.180630E+11 | 0.389187E+10 | 0.617796E+11 | 0.102599E+10 | 0.946041E+10 | 1343621.24 | 0.00 | 0.786511E+11 | 0.00 | 0.00 | 0.148885E+10 | 0.00 | 0.00 |
September | 0.162157E+11 | 0.392864E+10 | 0.572729E+11 | 0.943413E+09 | 0.866587E+10 | 1267813.82 | 0.00 | 0.722464E+11 | 0.00 | 0.00 | 0.141443E+10 | 0.00 | 0.00 |
October | 0.168730E+11 | 0.425166E+10 | 0.593671E+11 | 0.979738E+09 | 0.858457E+10 | 1312252.65 | 0.00 | 0.692220E+11 | 0.00 | 0.00 | 0.142445E+10 | 0.00 | 0.00 |
November | 0.168255E+11 | 0.431234E+10 | 0.580818E+11 | 0.961541E+09 | 0.884292E+10 | 1278270.02 | 0.00 | 0.654193E+11 | 0.00 | 0.00 | 0.137218E+10 | 0.00 | 0.00 |
December | 0.165030E+11 | 0.452021E+10 | 0.583511E+11 | 0.959206E+09 | 0.854717E+10 | 1299182.41 | 0.00 | 0.613935E+11 | 0.00 | 0.00 | 0.140072E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.202069E+12 | 0.485023E+11 | 0.705434E+12 | 0.116549E+11 | 0.113156E+12 | 15535293.87 | 0.00 | 0.867976E+12 | 0.00 | 0.00 | 0.172917E+11 | 0.00 | 0.00 |
Minimum of Months | 0.153704E+11 | 0.364255E+10 | 0.537310E+11 | 0.886636E+09 | 0.854717E+10 | 1186778.30 | 0.00 | 0.613935E+11 | 0.00 | 0.00 | 0.131872E+10 | 0.00 | 0.00 |
Maximum of Months | 0.181343E+11 | 0.452021E+10 | 0.617796E+11 | 0.102602E+10 | 0.110169E+11 | 1343621.24 | 0.00 | 0.879597E+11 | 0.00 | 0.00 | 0.153020E+10 | 0.00 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [J] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [J] | COGENERATION:NATURALGAS [] | HUMIDIFIER:NATURALGAS [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.737222E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.665591E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.755697E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.699336E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.727864E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.708088E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.700525E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.734945E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.693618E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.723731E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.712261E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.726908E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.858578E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.665591E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.755697E+10 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum} [W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | EXTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | FANS:ELECTRICITY {Maximum} [W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY {Maximum} [W] | PUMPS:ELECTRICITY {TIMESTAMP} | HEATING:ELECTRICITY {Maximum} [W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 19148.86 | 02-JAN-16:00 | 5557.43 | 01-JAN-06:10 | 45864.70 | 02-JAN-08:09 | 829.88 | 02-JAN-16:00 | 12770.20 | 17-JAN-15:09 | 0.73 | 01-JAN-06:10 | 0.00 | 01-JAN-00:10 |
February | 17680.69 | 07-FEB-16:00 | 5557.43 | 01-FEB-06:10 | 45864.70 | 01-FEB-08:09 | 829.46 | 08-FEB-08:20 | 14767.15 | 21-FEB-15:09 | 0.73 | 01-FEB-06:10 | 0.00 | 01-FEB-00:10 |
March | 17987.73 | 01-MAR-16:00 | 5557.43 | 01-MAR-06:10 | 45864.70 | 01-MAR-08:09 | 829.84 | 28-MAR-07:19 | 14300.45 | 20-MAR-15:09 | 0.73 | 01-MAR-06:10 | 0.00 | 01-MAR-00:10 |
April | 17239.45 | 21-APR-07:10 | 5557.43 | 01-APR-05:10 | 45864.70 | 03-APR-07:10 | 829.85 | 21-APR-07:19 | 13190.81 | 17-APR-15:20 | 0.73 | 01-APR-05:10 | 0.00 | 01-APR-00:10 |
May | 17426.04 | 17-MAY-07:10 | 5557.43 | 01-MAY-05:10 | 45864.70 | 01-MAY-07:10 | 830.10 | 17-MAY-07:19 | 14018.31 | 30-MAY-12:30 | 0.73 | 01-MAY-05:19 | 0.00 | 01-MAY-00:10 |
June | 17248.12 | 20-JUN-07:10 | 5557.43 | 01-JUN-05:10 | 45864.70 | 01-JUN-07:10 | 829.86 | 20-JUN-07:19 | 15154.29 | 12-JUN-15:20 | 0.73 | 01-JUN-05:10 | 0.00 | 01-JUN-00:10 |
July | 17336.67 | 11-JUL-07:10 | 5557.43 | 01-JUL-05:10 | 45864.70 | 03-JUL-07:10 | 829.98 | 11-JUL-07:19 | 12472.15 | 17-JUL-12:00 | 0.73 | 01-JUL-05:10 | 0.00 | 01-JUL-00:10 |
August | 17347.47 | 21-AUG-07:10 | 5557.43 | 01-AUG-05:10 | 45864.70 | 01-AUG-07:10 | 830.00 | 21-AUG-07:19 | 12853.46 | 14-AUG-14:30 | 0.73 | 01-AUG-05:10 | 0.00 | 01-AUG-00:10 |
September | 17242.07 | 21-SEP-07:10 | 5557.43 | 01-SEP-05:10 | 45864.70 | 01-SEP-07:10 | 829.86 | 21-SEP-07:19 | 12891.94 | 05-SEP-12:00 | 0.73 | 01-SEP-05:10 | 0.00 | 01-SEP-00:10 |
October | 17500.64 | 30-OCT-15:00 | 5557.43 | 01-OCT-05:10 | 45864.70 | 02-OCT-07:10 | 830.18 | 23-OCT-07:19 | 13013.44 | 10-OCT-14:09 | 0.73 | 01-OCT-05:10 | 0.00 | 01-OCT-00:10 |
November | 19726.72 | 09-NOV-16:00 | 5557.43 | 01-NOV-05:10 | 45864.70 | 01-NOV-07:10 | 831.17 | 09-NOV-16:00 | 13178.37 | 13-NOV-13:30 | 0.73 | 01-NOV-05:10 | 0.00 | 01-NOV-00:10 |
December | 19951.89 | 18-DEC-16:00 | 5557.43 | 01-DEC-17:30 | 45864.70 | 01-DEC-08:09 | 831.86 | 18-DEC-16:00 | 13023.00 | 26-DEC-13:00 | 0.73 | 01-DEC-06:10 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 17239.45 | 5557.43 | 45864.70 | 829.46 | 12472.15 | 0.73 | 0.00 | |||||||
Maximum of Months | 19951.89 | 5557.43 | 45864.70 | 831.86 | 15154.29 | 0.73 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum} [W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY {Maximum} [W] | HEATRECOVERY:ELECTRICITY {TIMESTAMP} | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 65401.50 | 04-JAN-13:39 | 0.00 | 0.00 | 907.56 | 01-JAN-06:40 | 0.00 | 0.00 |
February | 73354.26 | 13-FEB-14:00 | 0.00 | 0.00 | 907.56 | 01-FEB-05:19 | 0.00 | 0.00 |
March | 74163.81 | 20-MAR-15:09 | 0.00 | 0.00 | 907.56 | 01-MAR-05:19 | 0.00 | 0.00 |
April | 74933.55 | 11-APR-15:00 | 0.00 | 0.00 | 907.56 | 01-APR-05:19 | 0.00 | 0.00 |
May | 83770.67 | 04-MAY-12:00 | 0.00 | 0.00 | 907.56 | 01-MAY-04:19 | 0.00 | 0.00 |
June | 86862.83 | 13-JUN-15:20 | 0.00 | 0.00 | 907.56 | 01-JUN-04:19 | 0.00 | 0.00 |
July | 68570.55 | 17-JUL-12:00 | 0.00 | 0.00 | 907.56 | 01-JUL-05:19 | 0.00 | 0.00 |
August | 76253.96 | 14-AUG-12:00 | 0.00 | 0.00 | 907.56 | 01-AUG-04:19 | 0.00 | 0.00 |
September | 73302.65 | 05-SEP-12:20 | 0.00 | 0.00 | 907.56 | 01-SEP-05:19 | 0.00 | 0.00 |
October | 71120.18 | 16-OCT-13:00 | 0.00 | 0.00 | 907.56 | 01-OCT-06:49 | 0.00 | 0.00 |
November | 69722.63 | 13-NOV-13:00 | 0.00 | 0.00 | 907.56 | 01-NOV-05:19 | 0.00 | 0.00 |
December | 64652.77 | 11-DEC-13:09 | 0.00 | 0.00 | 907.56 | 01-DEC-06:19 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 64652.77 | 0.00 | 0.00 | 907.56 | 0.00 | 0.00 | ||
Maximum of Months | 86862.83 | 0.00 | 0.00 | 907.56 | 0.00 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 138455.04 | 04-JAN-13:00 | 16818.70 | 42402.18 | 0.00 | 828.07 | 12131.37 | 0.73 | 0.00 | 65366.45 | 0.00 |
February | 145689.60 | 13-FEB-14:00 | 16818.70 | 40588.47 | 0.00 | 827.42 | 13192.47 | 0.73 | 0.00 | 73354.26 | 0.00 |
March | 149091.61 | 20-MAR-15:09 | 16818.70 | 42072.41 | 0.00 | 827.95 | 14300.45 | 0.73 | 0.00 | 74163.81 | 0.00 |
April | 148171.98 | 11-APR-15:50 | 16818.70 | 42072.41 | 0.00 | 827.95 | 12702.04 | 0.73 | 0.00 | 74842.59 | 0.00 |
May | 157001.67 | 04-MAY-12:00 | 16818.70 | 42402.18 | 0.00 | 828.07 | 12273.78 | 0.73 | 0.00 | 83770.67 | 0.00 |
June | 162130.67 | 13-JUN-15:20 | 16818.70 | 42072.41 | 0.00 | 827.95 | 14640.49 | 0.73 | 0.00 | 86862.83 | 0.00 |
July | 141999.93 | 17-JUL-12:00 | 16818.70 | 42402.18 | 0.00 | 828.07 | 12472.15 | 0.73 | 0.00 | 68570.55 | 0.00 |
August | 149806.90 | 14-AUG-12:00 | 16818.70 | 42402.18 | 0.00 | 828.07 | 12595.72 | 0.73 | 0.00 | 76253.96 | 0.00 |
September | 147064.36 | 05-SEP-12:00 | 16818.70 | 42402.18 | 0.00 | 828.07 | 12891.94 | 0.73 | 0.00 | 73215.20 | 0.00 |
October | 143179.54 | 16-OCT-12:00 | 16818.70 | 42402.18 | 0.00 | 828.07 | 12285.97 | 0.73 | 0.00 | 69936.34 | 0.00 |
November | 143804.51 | 13-NOV-13:00 | 16818.70 | 42402.18 | 0.00 | 828.07 | 13124.66 | 0.73 | 0.00 | 69722.63 | 0.00 |
December | 136639.28 | 12-DEC-13:00 | 16818.70 | 42402.18 | 0.00 | 828.07 | 11037.01 | 0.73 | 0.00 | 64645.05 | 0.00 |
Annual Sum or Average | 0.00 | ||||||||||
Minimum of Months | 136639.28 | 16818.70 | 40588.47 | 0.00 | 827.42 | 11037.01 | 0.73 | 0.00 | 64645.05 | 0.00 | |
Maximum of Months | 162130.67 | 16818.70 | 42402.18 | 0.00 | 828.07 | 14640.49 | 0.73 | 0.00 | 86862.83 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS {Maximum} [W] | HEATING:NATURALGAS {TIMESTAMP} | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS {Maximum} [W] | WATERSYSTEMS:NATURALGAS {TIMESTAMP} | COGENERATION:NATURALGAS [] | |
January | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 8617.92 | 05-JAN-12:09 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 8614.69 | 07-FEB-12:09 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 8599.91 | 08-MAR-12:09 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 8578.77 | 04-APR-11:09 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 8558.69 | 02-MAY-11:09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 8534.44 | 05-JUN-11:09 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 8526.46 | 24-JUL-11:09 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 8537.64 | 28-AUG-11:09 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 8556.53 | 25-SEP-11:20 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 8581.56 | 30-OCT-11:20 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 8600.72 | 29-NOV-12:09 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 8614.36 | 27-DEC-12:20 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 8526.46 | 0.00 | ||
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 8617.92 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 27.29 | 0.00 | 27.29 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 26.21 | 0.00 | 26.21 |
Annual Sum or Average | 0.00 | 0.00 | 0.33 | 26.75 | 0.00 | 26.75 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 27.29 | 0.00 | 27.29 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 1.67 | 27.44 | 1.67 | 27.44 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 2.17 | 27.53 | 2.17 | 27.53 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 4.33 | 27.50 | 4.00 | 27.50 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 7.83 | 27.71 | 6.67 | 27.72 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 8.33 | 27.77 | 6.83 | 27.79 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 6.17 | 27.48 | 5.83 | 27.48 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 3.00 | 27.54 | 2.67 | 27.56 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 2.33 | 27.44 | 2.33 | 27.44 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 27.37 | 0.83 | 27.37 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 36.67 | 27.60 | 33.00 | 27.60 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 8.33 | 27.77 | 6.83 | 27.79 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 1.83 | 27.46 | 1.83 | 27.46 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 7.67 | 27.54 | 7.67 | 27.54 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 9.00 | 27.75 | 8.67 | 27.76 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 10.33 | 27.81 | 10.33 | 27.81 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 9.50 | 27.89 | 9.00 | 27.90 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 9.00 | 27.73 | 8.50 | 27.74 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 6.33 | 27.46 | 6.33 | 27.46 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 5.00 | 27.77 | 5.00 | 27.77 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 8.17 | 27.69 | 8.00 | 27.70 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 5.83 | 27.57 | 5.83 | 27.57 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 3.83 | 27.42 | 3.83 | 27.42 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 4.00 | 27.36 | 4.00 | 27.36 |
Annual Sum or Average | 0.00 | 0.00 | 80.50 | 27.67 | 79.00 | 27.67 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 1.83 | 27.36 | 1.83 | 27.36 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 10.33 | 27.89 | 10.33 | 27.90 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 11.50 | 27.31 | 11.17 | 27.31 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 8.67 | 27.74 | 8.50 | 27.74 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 6.17 | 27.69 | 5.83 | 27.70 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 3.67 | 27.49 | 3.67 | 27.49 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 4.50 | 27.58 | 4.17 | 27.59 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 3.83 | 27.52 | 3.33 | 27.53 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 1.67 | 27.33 | 1.67 | 27.33 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 2.00 | 27.47 | 2.00 | 27.47 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 3.83 | 27.49 | 3.83 | 27.49 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 6.83 | 27.61 | 6.83 | 27.61 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 8.00 | 27.75 | 7.83 | 27.76 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 15.17 | 26.74 | 15.17 | 26.74 |
Annual Sum or Average | 0.00 | 0.00 | 75.83 | 27.40 | 74.00 | 27.40 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 1.67 | 26.74 | 1.67 | 26.74 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 15.17 | 27.75 | 15.17 | 27.76 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 5.33 | 27.97 | 5.00 | 27.99 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 5.17 | 27.90 | 5.00 | 27.90 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 5.67 | 28.18 | 4.50 | 28.22 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 6.33 | 28.11 | 4.67 | 28.16 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 6.00 | 28.09 | 4.33 | 28.14 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 6.50 | 28.04 | 4.50 | 28.08 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 4.50 | 27.72 | 3.67 | 27.71 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 3.67 | 28.00 | 3.00 | 28.02 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 4.83 | 27.94 | 3.67 | 27.96 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 4.00 | 27.74 | 3.67 | 27.75 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 3.33 | 27.72 | 3.33 | 27.72 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 5.00 | 27.91 | 5.00 | 27.91 |
Annual Sum or Average | 0.00 | 0.00 | 60.33 | 27.96 | 50.33 | 27.98 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 3.33 | 27.72 | 3.00 | 27.71 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 6.50 | 28.18 | 5.00 | 28.22 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 3.67 | 27.39 | 3.33 | 27.42 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 4.33 | 27.54 | 3.67 | 27.55 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 27.34 | 0.67 | 27.34 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 8.67 | 27.46 | 7.67 | 27.48 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 4.33 | 27.54 | 3.67 | 27.55 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 27.35 | 0.67 | 27.35 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 2.33 | 27.46 | 2.33 | 27.46 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 5.67 | 27.52 | 5.67 | 27.52 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 7.33 | 27.52 | 7.33 | 27.52 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 8.67 | 27.56 | 8.33 | 27.58 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 4.83 | 27.57 | 4.83 | 27.57 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 27.39 | 1.00 | 27.39 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 3.83 | 27.47 | 3.83 | 27.47 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 5.00 | 27.51 | 5.00 | 27.51 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 3.17 | 27.43 | 3.17 | 27.43 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 27.31 | 0.50 | 27.31 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 27.31 | 0.83 | 27.31 |
Annual Sum or Average | 0.00 | 0.00 | 43.83 | 27.51 | 43.50 | 27.51 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 27.31 | 0.50 | 27.31 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 8.67 | 27.57 | 8.33 | 27.58 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 116.00 | 25.40 | 116.00 | 25.40 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 107.17 | 25.44 | 106.83 | 25.44 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 70.50 | 25.46 | 70.50 | 25.46 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 41.17 | 25.72 | 41.17 | 25.72 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 46.33 | 25.68 | 46.33 | 25.68 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 44.50 | 25.82 | 44.50 | 25.82 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 29.83 | 25.31 | 29.83 | 25.31 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 33.17 | 25.51 | 33.17 | 25.51 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 31.67 | 25.47 | 31.67 | 25.47 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 40.17 | 25.35 | 40.17 | 25.35 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 71.50 | 25.33 | 71.50 | 25.33 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 93.83 | 25.46 | 93.83 | 25.46 |
Annual Sum or Average | 0.00 | 0.00 | 725.83 | 25.48 | 725.50 | 25.48 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 29.83 | 25.31 | 29.83 | 25.31 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 116.00 | 25.82 | 116.00 | 25.82 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 4.17 | 27.65 | 4.17 | 27.65 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 3.00 | 27.75 | 3.00 | 27.75 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 4.50 | 27.81 | 3.67 | 27.83 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 5.33 | 27.74 | 4.17 | 27.76 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 5.17 | 27.72 | 3.83 | 27.76 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 5.17 | 27.74 | 3.67 | 27.75 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 1.83 | 27.71 | 1.50 | 27.68 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 3.00 | 27.69 | 2.33 | 27.71 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 3.33 | 27.77 | 2.33 | 27.80 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 2.00 | 27.51 | 1.83 | 27.51 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 1.50 | 27.54 | 1.50 | 27.54 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 3.50 | 27.61 | 3.50 | 27.61 |
Annual Sum or Average | 0.00 | 0.00 | 42.50 | 27.71 | 35.50 | 27.72 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 1.50 | 27.51 | 1.50 | 27.51 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 5.33 | 27.81 | 4.17 | 27.83 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 4.67 | 27.49 | 4.33 | 27.50 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 5.67 | 27.55 | 5.00 | 27.56 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 27.43 | 0.83 | 27.43 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 27.27 | 0.33 | 27.27 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 11.50 | 27.51 | 10.50 | 27.51 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 5.67 | 27.55 | 5.00 | 27.56 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 27.51 | 0.67 | 27.51 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 2.33 | 27.53 | 2.33 | 27.53 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 6.00 | 27.62 | 6.00 | 27.62 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 7.17 | 27.62 | 7.17 | 27.62 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 7.67 | 27.67 | 7.67 | 27.67 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 4.83 | 27.61 | 4.83 | 27.61 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 27.48 | 0.83 | 27.48 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 3.50 | 27.55 | 3.50 | 27.55 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 4.17 | 27.57 | 4.17 | 27.57 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 3.17 | 27.47 | 3.17 | 27.47 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 | 27.39 | 1.17 | 27.39 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 | 27.39 | 1.17 | 27.39 |
Annual Sum or Average | 0.00 | 0.00 | 42.67 | 27.58 | 42.67 | 27.58 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 27.39 | 0.67 | 27.39 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 7.67 | 27.67 | 7.67 | 27.67 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 22.83 | 25.81 | 22.83 | 25.81 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 10.17 | 26.65 | 10.17 | 26.65 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 3.17 | 27.46 | 3.17 | 27.46 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 27.27 | 0.67 | 27.27 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 3.33 | 27.51 | 3.33 | 27.51 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 5.50 | 27.62 | 5.50 | 27.62 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 29.67 | 25.63 | 29.67 | 25.63 |
Annual Sum or Average | 0.00 | 0.00 | 75.33 | 26.14 | 75.33 | 26.14 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 29.67 | 27.62 | 29.67 | 27.62 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 4.67 | 27.75 | 4.67 | 27.75 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 3.17 | 27.86 | 3.17 | 27.86 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 4.67 | 27.94 | 3.83 | 27.96 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 5.17 | 27.87 | 4.17 | 27.89 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 4.50 | 27.92 | 3.67 | 27.93 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 5.17 | 27.82 | 3.83 | 27.84 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 1.83 | 27.79 | 1.50 | 27.78 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 2.67 | 27.81 | 2.17 | 27.83 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 3.17 | 27.88 | 2.33 | 27.91 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 2.17 | 27.60 | 2.00 | 27.60 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 1.67 | 27.64 | 1.67 | 27.64 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 4.33 | 27.66 | 4.33 | 27.66 |
Annual Sum or Average | 0.00 | 0.00 | 43.17 | 27.81 | 37.33 | 27.82 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 1.67 | 27.60 | 1.50 | 27.60 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 5.17 | 27.94 | 4.67 | 27.96 |
Report: ComfortReportSimple55Monthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 501.83 | 24.39 | 0.00 | 24.39 |
February | 0.00 | 0.00 | 453.33 | 24.34 | 0.00 | 24.34 |
March | 0.00 | 0.00 | 513.83 | 24.30 | 0.00 | 24.30 |
April | 0.00 | 0.00 | 485.00 | 24.31 | 0.00 | 24.31 |
May | 0.00 | 0.00 | 508.00 | 24.33 | 0.00 | 24.33 |
June | 0.00 | 0.00 | 496.00 | 24.32 | 0.00 | 24.32 |
July | 0.00 | 0.00 | 497.00 | 24.37 | 0.00 | 24.37 |
August | 0.00 | 0.00 | 513.00 | 24.33 | 0.00 | 24.33 |
September | 0.00 | 0.00 | 484.00 | 24.33 | 0.00 | 24.33 |
October | 0.00 | 0.00 | 502.00 | 24.38 | 0.00 | 24.38 |
November | 0.00 | 0.00 | 488.67 | 24.39 | 0.00 | 24.39 |
December | 0.00 | 0.00 | 494.50 | 24.35 | 0.00 | 24.35 |
Annual Sum or Average | 0.00 | 5937.17 | 24.34 | 0.00 | 24.34 | |
Minimum of Months | 0.00 | 0.00 | 453.33 | 24.30 | 0.00 | 24.30 |
Maximum of Months | 0.00 | 0.00 | 513.83 | 24.39 | 0.00 | 24.39 |
Report: ComfortReportSimple55Monthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.83 | 23.32 | 402.67 | 24.32 | 0.00 | 24.32 |
February | 0.00 | 0.00 | 370.17 | 24.27 | 0.00 | 24.27 |
March | 0.33 | 23.34 | 427.17 | 24.23 | 0.00 | 24.23 |
April | 0.00 | 0.00 | 410.17 | 24.25 | 0.00 | 24.25 |
May | 0.00 | 0.00 | 441.67 | 24.27 | 0.00 | 24.27 |
June | 0.00 | 0.00 | 443.00 | 24.25 | 0.00 | 24.25 |
July | 0.00 | 0.00 | 405.50 | 24.31 | 0.00 | 24.31 |
August | 2.67 | 23.24 | 414.33 | 24.26 | 0.00 | 24.26 |
September | 3.33 | 23.23 | 386.17 | 24.26 | 0.00 | 24.26 |
October | 1.17 | 23.29 | 400.17 | 24.32 | 0.00 | 24.32 |
November | 0.67 | 23.31 | 401.50 | 24.31 | 0.00 | 24.31 |
December | 3.83 | 23.28 | 373.67 | 24.28 | 0.00 | 24.28 |
Annual Sum or Average | 12.83 | 23.27 | 4876.17 | 24.28 | 0.00 | 24.28 |
Minimum of Months | 0.00 | 0.00 | 370.17 | 24.23 | 0.00 | 24.23 |
Maximum of Months | 3.83 | 23.34 | 443.00 | 24.32 | 0.00 | 24.32 |
Report: ComfortReportSimple55Monthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 8.33 | 23.30 | 395.50 | 24.30 | 0.00 | 24.30 |
February | 1.67 | 23.30 | 369.33 | 24.28 | 0.00 | 24.28 |
March | 2.83 | 23.29 | 440.67 | 24.24 | 0.00 | 24.24 |
April | 0.00 | 0.00 | 441.50 | 24.28 | 0.00 | 24.28 |
May | 1.67 | 23.27 | 458.67 | 24.30 | 0.00 | 24.30 |
June | 0.50 | 23.28 | 458.67 | 24.28 | 0.00 | 24.28 |
July | 0.17 | 23.30 | 422.33 | 24.31 | 0.00 | 24.31 |
August | 5.83 | 23.21 | 417.17 | 24.26 | 0.00 | 24.26 |
September | 4.33 | 23.16 | 399.83 | 24.27 | 0.00 | 24.27 |
October | 5.67 | 23.24 | 399.83 | 24.32 | 0.00 | 24.32 |
November | 4.33 | 23.28 | 389.00 | 24.31 | 0.00 | 24.31 |
December | 21.67 | 23.25 | 360.33 | 24.23 | 0.00 | 24.23 |
Annual Sum or Average | 57.00 | 23.25 | 4952.83 | 24.28 | 0.00 | 24.28 |
Minimum of Months | 0.00 | 0.00 | 360.33 | 24.23 | 0.00 | 24.23 |
Maximum of Months | 21.67 | 23.30 | 458.67 | 24.32 | 0.00 | 24.32 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 15.67 | 23.75 | 451.00 | 24.40 | 2.17 | 24.41 |
February | 13.33 | 26.59 | 417.33 | 24.50 | 12.67 | 24.57 |
March | 19.83 | 26.41 | 498.00 | 24.45 | 19.50 | 24.52 |
April | 25.17 | 26.69 | 482.83 | 24.58 | 25.17 | 24.68 |
May | 38.67 | 26.78 | 500.33 | 24.68 | 38.50 | 24.82 |
June | 37.50 | 26.83 | 494.17 | 24.65 | 37.50 | 24.80 |
July | 33.67 | 26.73 | 483.17 | 24.69 | 33.67 | 24.81 |
August | 32.33 | 26.22 | 494.17 | 24.50 | 32.33 | 24.60 |
September | 16.33 | 26.71 | 463.33 | 24.51 | 16.33 | 24.59 |
October | 15.17 | 26.56 | 462.00 | 24.55 | 14.50 | 24.61 |
November | 7.33 | 25.56 | 448.83 | 24.46 | 4.67 | 24.48 |
December | 24.00 | 23.49 | 420.50 | 24.36 | 1.83 | 24.37 |
Annual Sum or Average | 279.00 | 26.17 | 5615.67 | 24.53 | 238.83 | 24.62 |
Minimum of Months | 7.33 | 23.49 | 417.33 | 24.36 | 1.83 | 24.37 |
Maximum of Months | 38.67 | 26.83 | 500.33 | 24.69 | 38.50 | 24.82 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 22.50 | 26.60 | 470.50 | 24.59 | 21.17 | 24.68 |
February | 40.33 | 26.71 | 435.33 | 24.70 | 40.33 | 24.86 |
March | 43.67 | 26.72 | 500.67 | 24.62 | 43.50 | 24.77 |
April | 49.00 | 26.82 | 481.83 | 24.75 | 49.00 | 24.92 |
May | 50.67 | 26.74 | 493.50 | 24.73 | 49.67 | 24.90 |
June | 42.50 | 26.78 | 491.50 | 24.66 | 42.33 | 24.81 |
July | 39.33 | 26.71 | 473.17 | 24.71 | 39.33 | 24.85 |
August | 42.67 | 26.43 | 489.00 | 24.57 | 42.00 | 24.71 |
September | 39.83 | 26.75 | 459.00 | 24.68 | 39.17 | 24.84 |
October | 44.33 | 26.34 | 464.33 | 24.68 | 39.33 | 24.83 |
November | 32.17 | 26.31 | 452.83 | 24.63 | 28.50 | 24.74 |
December | 37.67 | 25.89 | 442.33 | 24.60 | 28.67 | 24.72 |
Annual Sum or Average | 484.67 | 26.58 | 5654.00 | 24.66 | 463.00 | 24.80 |
Minimum of Months | 22.50 | 25.89 | 435.33 | 24.57 | 21.17 | 24.68 |
Maximum of Months | 50.67 | 26.82 | 500.67 | 24.75 | 49.67 | 24.92 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 44.00 | 26.80 | 485.67 | 24.76 | 42.00 | 24.92 |
February | 36.33 | 26.91 | 441.33 | 24.71 | 36.33 | 24.87 |
March | 31.00 | 26.67 | 502.67 | 24.54 | 31.00 | 24.66 |
April | 23.50 | 26.68 | 481.50 | 24.57 | 23.50 | 24.66 |
May | 28.50 | 26.60 | 497.50 | 24.58 | 28.17 | 24.69 |
June | 25.83 | 26.63 | 492.33 | 24.54 | 25.83 | 24.64 |
July | 17.83 | 26.67 | 474.50 | 24.58 | 17.83 | 24.65 |
August | 29.50 | 26.09 | 490.83 | 24.46 | 29.50 | 24.55 |
September | 21.00 | 26.74 | 464.83 | 24.55 | 21.00 | 24.64 |
October | 36.50 | 26.75 | 471.50 | 24.70 | 36.00 | 24.84 |
November | 37.17 | 26.91 | 472.50 | 24.71 | 37.17 | 24.86 |
December | 45.67 | 26.72 | 461.50 | 24.78 | 42.50 | 24.94 |
Annual Sum or Average | 376.83 | 26.70 | 5736.67 | 24.62 | 370.83 | 24.74 |
Minimum of Months | 17.83 | 26.09 | 441.33 | 24.46 | 17.83 | 24.55 |
Maximum of Months | 45.67 | 26.91 | 502.67 | 24.78 | 42.50 | 24.94 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 45.50 | 24.81 | 426.67 | 24.50 | 21.50 | 24.60 |
February | 35.50 | 25.35 | 397.50 | 24.53 | 21.33 | 24.64 |
March | 33.17 | 26.13 | 472.33 | 24.52 | 27.83 | 24.64 |
April | 30.17 | 26.84 | 471.83 | 24.62 | 30.17 | 24.74 |
May | 35.67 | 26.37 | 479.67 | 24.60 | 31.83 | 24.73 |
June | 30.00 | 26.68 | 476.33 | 24.57 | 29.17 | 24.69 |
July | 28.67 | 25.95 | 445.67 | 24.60 | 22.67 | 24.70 |
August | 43.17 | 25.68 | 462.50 | 24.50 | 34.50 | 24.61 |
September | 23.50 | 26.17 | 433.17 | 24.54 | 19.33 | 24.63 |
October | 41.83 | 25.08 | 432.33 | 24.55 | 23.17 | 24.65 |
November | 35.00 | 25.02 | 420.33 | 24.50 | 18.50 | 24.59 |
December | 63.67 | 24.24 | 399.33 | 24.42 | 21.00 | 24.52 |
Annual Sum or Average | 445.83 | 25.53 | 5317.67 | 24.54 | 301.00 | 24.65 |
Minimum of Months | 23.50 | 24.24 | 397.50 | 24.42 | 18.50 | 24.52 |
Maximum of Months | 63.67 | 26.84 | 479.67 | 24.62 | 34.50 | 24.74 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 490.33 | 24.38 | 0.00 | 24.38 |
February | 0.00 | 0.00 | 453.50 | 24.39 | 0.00 | 24.39 |
March | 0.00 | 0.00 | 512.00 | 24.34 | 0.00 | 24.34 |
April | 0.00 | 0.00 | 485.00 | 24.43 | 0.00 | 24.43 |
May | 15.00 | 26.83 | 508.00 | 24.57 | 15.00 | 24.64 |
June | 20.33 | 26.84 | 496.00 | 24.59 | 20.33 | 24.68 |
July | 5.83 | 26.83 | 497.00 | 24.58 | 5.83 | 24.60 |
August | 9.33 | 26.67 | 514.00 | 24.45 | 9.33 | 24.48 |
September | 0.67 | 26.88 | 485.00 | 24.43 | 0.67 | 24.43 |
October | 0.00 | 0.00 | 501.50 | 24.44 | 0.00 | 24.44 |
November | 0.00 | 0.00 | 487.83 | 24.41 | 0.00 | 24.41 |
December | 0.17 | 23.49 | 476.83 | 24.37 | 0.00 | 24.37 |
Annual Sum or Average | 51.33 | 26.79 | 5907.00 | 24.45 | 51.17 | 24.47 |
Minimum of Months | 0.00 | 0.00 | 453.50 | 24.34 | 0.00 | 24.34 |
Maximum of Months | 20.33 | 26.88 | 514.00 | 24.59 | 20.33 | 24.68 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 5.17 | 26.96 | 502.00 | 24.54 | 5.17 | 24.56 |
February | 16.50 | 26.84 | 454.00 | 24.61 | 16.50 | 24.69 |
March | 24.50 | 26.86 | 514.00 | 24.57 | 24.50 | 24.67 |
April | 32.50 | 26.85 | 485.00 | 24.70 | 32.50 | 24.82 |
May | 36.33 | 26.85 | 508.00 | 24.70 | 36.33 | 24.83 |
June | 27.17 | 26.81 | 496.00 | 24.62 | 27.17 | 24.73 |
July | 14.17 | 26.92 | 497.00 | 24.63 | 14.17 | 24.69 |
August | 27.50 | 26.80 | 514.00 | 24.57 | 27.50 | 24.68 |
September | 26.67 | 26.82 | 485.00 | 24.65 | 26.67 | 24.75 |
October | 18.83 | 26.87 | 501.83 | 24.62 | 18.83 | 24.70 |
November | 7.50 | 26.93 | 489.00 | 24.56 | 7.50 | 24.60 |
December | 7.00 | 26.95 | 494.17 | 24.53 | 7.00 | 24.57 |
Annual Sum or Average | 243.83 | 26.85 | 5940.00 | 24.61 | 243.83 | 24.69 |
Minimum of Months | 5.17 | 26.80 | 454.00 | 24.53 | 5.17 | 24.56 |
Maximum of Months | 36.33 | 26.96 | 514.00 | 24.70 | 36.33 | 24.83 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 106.00 | 25.62 | 501.17 | 25.03 | 106.00 | 25.11 |
February | 91.00 | 25.62 | 454.00 | 25.01 | 91.00 | 25.10 |
March | 100.17 | 24.99 | 514.00 | 24.71 | 100.17 | 24.75 |
April | 122.67 | 24.66 | 485.00 | 24.61 | 122.67 | 24.62 |
May | 192.17 | 24.51 | 508.00 | 24.60 | 192.17 | 24.58 |
June | 183.50 | 24.54 | 496.00 | 24.60 | 183.50 | 24.58 |
July | 119.17 | 24.38 | 497.00 | 24.54 | 119.17 | 24.51 |
August | 222.00 | 24.37 | 514.00 | 24.46 | 222.00 | 24.44 |
September | 160.50 | 24.37 | 485.00 | 24.52 | 160.50 | 24.49 |
October | 163.50 | 24.59 | 502.00 | 24.64 | 163.50 | 24.63 |
November | 135.50 | 25.06 | 489.00 | 24.85 | 135.50 | 24.88 |
December | 112.33 | 25.47 | 494.83 | 24.96 | 112.33 | 25.04 |
Annual Sum or Average | 1708.50 | 24.75 | 5940.00 | 24.70 | 1708.50 | 24.71 |
Minimum of Months | 91.00 | 24.37 | 454.00 | 24.46 | 91.00 | 24.44 |
Maximum of Months | 222.00 | 25.62 | 514.00 | 25.03 | 222.00 | 25.11 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 16.67 | 26.87 | 495.33 | 24.57 | 16.67 | 24.64 |
February | 14.50 | 26.89 | 454.00 | 24.56 | 14.50 | 24.63 |
March | 16.00 | 26.94 | 513.83 | 24.52 | 16.00 | 24.59 |
April | 19.50 | 26.88 | 485.00 | 24.62 | 19.50 | 24.70 |
May | 20.67 | 26.91 | 507.83 | 24.61 | 20.67 | 24.69 |
June | 20.17 | 26.86 | 496.00 | 24.58 | 20.17 | 24.67 |
July | 10.50 | 26.85 | 497.00 | 24.59 | 10.50 | 24.64 |
August | 21.17 | 26.79 | 514.00 | 24.54 | 21.17 | 24.62 |
September | 12.50 | 26.90 | 485.00 | 24.55 | 12.50 | 24.61 |
October | 12.00 | 26.79 | 501.00 | 24.57 | 12.00 | 24.62 |
November | 7.17 | 26.87 | 488.50 | 24.52 | 7.17 | 24.55 |
December | 15.50 | 26.81 | 483.33 | 24.54 | 15.33 | 24.61 |
Annual Sum or Average | 186.33 | 26.86 | 5920.83 | 24.56 | 186.17 | 24.63 |
Minimum of Months | 7.17 | 26.79 | 454.00 | 24.52 | 7.17 | 24.55 |
Maximum of Months | 21.17 | 26.94 | 514.00 | 24.62 | 21.17 | 24.70 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 468.00 | 24.40 | 0.00 | 24.40 |
February | 0.17 | 26.88 | 436.00 | 24.41 | 0.17 | 24.41 |
March | 2.00 | 26.35 | 504.00 | 24.36 | 2.00 | 24.37 |
April | 5.33 | 26.60 | 484.67 | 24.46 | 5.33 | 24.48 |
May | 27.67 | 26.76 | 504.67 | 24.62 | 27.67 | 24.72 |
June | 27.50 | 26.80 | 494.67 | 24.60 | 27.50 | 24.71 |
July | 10.17 | 26.81 | 495.00 | 24.57 | 10.17 | 24.61 |
August | 20.67 | 26.20 | 505.50 | 24.45 | 20.67 | 24.52 |
September | 1.17 | 26.93 | 474.50 | 24.41 | 1.17 | 24.42 |
October | 0.33 | 26.98 | 480.67 | 24.46 | 0.33 | 24.46 |
November | 0.00 | 0.00 | 470.00 | 24.42 | 0.00 | 24.42 |
December | 1.83 | 23.35 | 444.00 | 24.38 | 0.00 | 24.38 |
Annual Sum or Average | 96.83 | 26.58 | 5761.67 | 24.46 | 95.00 | 24.50 |
Minimum of Months | 0.00 | 0.00 | 436.00 | 24.36 | 0.00 | 24.37 |
Maximum of Months | 27.67 | 26.98 | 505.50 | 24.62 | 27.67 | 24.72 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 7.67 | 26.94 | 403.50 | 24.62 | 7.67 | 24.66 |
February | 19.50 | 26.83 | 371.00 | 24.71 | 19.50 | 24.81 |
March | 28.17 | 26.82 | 421.50 | 24.65 | 28.17 | 24.78 |
April | 37.33 | 26.79 | 408.33 | 24.79 | 37.33 | 24.94 |
May | 41.83 | 26.79 | 422.67 | 24.79 | 41.83 | 24.96 |
June | 31.00 | 26.77 | 414.17 | 24.70 | 31.00 | 24.83 |
July | 15.67 | 26.84 | 409.00 | 24.69 | 15.67 | 24.77 |
August | 35.17 | 26.54 | 415.83 | 24.64 | 35.17 | 24.78 |
September | 27.17 | 26.78 | 391.83 | 24.72 | 27.17 | 24.85 |
October | 22.00 | 26.74 | 397.67 | 24.72 | 21.50 | 24.82 |
November | 10.17 | 26.85 | 388.50 | 24.65 | 10.17 | 24.70 |
December | 12.17 | 26.66 | 379.17 | 24.64 | 11.50 | 24.70 |
Annual Sum or Average | 287.83 | 26.76 | 4823.17 | 24.69 | 286.67 | 24.81 |
Minimum of Months | 7.67 | 26.54 | 371.00 | 24.62 | 7.67 | 24.66 |
Maximum of Months | 41.83 | 26.94 | 422.67 | 24.79 | 41.83 | 24.96 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 36.83 | 26.94 | 495.17 | 24.78 | 36.83 | 24.92 |
February | 30.17 | 26.89 | 450.33 | 24.70 | 30.17 | 24.83 |
March | 16.83 | 26.79 | 507.83 | 24.48 | 16.83 | 24.55 |
April | 5.00 | 26.56 | 484.83 | 24.45 | 5.00 | 24.47 |
May | 10.50 | 26.60 | 503.67 | 24.48 | 10.50 | 24.53 |
June | 5.83 | 26.55 | 494.17 | 24.43 | 5.83 | 24.45 |
July | 1.33 | 26.37 | 489.00 | 24.47 | 1.33 | 24.47 |
August | 17.50 | 26.02 | 503.50 | 24.41 | 17.50 | 24.46 |
September | 2.50 | 26.89 | 475.17 | 24.44 | 2.50 | 24.45 |
October | 21.00 | 26.84 | 487.33 | 24.62 | 21.00 | 24.71 |
November | 29.50 | 26.89 | 481.00 | 24.70 | 29.50 | 24.82 |
December | 38.33 | 26.95 | 482.67 | 24.79 | 38.33 | 24.93 |
Annual Sum or Average | 215.33 | 26.79 | 5854.67 | 24.56 | 215.33 | 24.64 |
Minimum of Months | 1.33 | 26.02 | 450.33 | 24.41 | 1.33 | 24.45 |
Maximum of Months | 38.33 | 26.95 | 507.83 | 24.79 | 38.33 | 24.93 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 22.33 | 26.27 | 456.33 | 24.55 | 18.50 | 24.64 |
February | 15.33 | 26.89 | 423.67 | 24.54 | 15.33 | 24.62 |
March | 19.33 | 26.87 | 499.17 | 24.49 | 19.33 | 24.57 |
April | 24.00 | 26.84 | 481.17 | 24.58 | 24.00 | 24.69 |
May | 26.17 | 26.76 | 495.33 | 24.58 | 25.83 | 24.68 |
June | 22.83 | 26.78 | 490.33 | 24.53 | 22.83 | 24.63 |
July | 12.00 | 26.77 | 469.17 | 24.55 | 12.00 | 24.61 |
August | 30.00 | 26.38 | 487.00 | 24.50 | 30.00 | 24.61 |
September | 12.17 | 26.90 | 456.00 | 24.50 | 12.17 | 24.56 |
October | 15.00 | 26.42 | 454.83 | 24.56 | 13.50 | 24.62 |
November | 8.50 | 26.77 | 450.17 | 24.50 | 8.33 | 24.54 |
December | 22.50 | 25.94 | 429.50 | 24.53 | 17.00 | 24.61 |
Annual Sum or Average | 230.17 | 26.60 | 5592.67 | 24.53 | 218.83 | 24.62 |
Minimum of Months | 8.50 | 25.94 | 423.67 | 24.49 | 8.33 | 24.54 |
Maximum of Months | 30.00 | 26.90 | 499.17 | 24.58 | 30.00 | 24.69 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 24.38731 | 47.18818 | 0.55171 | 11.62780 |
February | 454.00000 | 24.34120 | 47.43700 | 0.54463 | 11.41084 |
March | 514.00000 | 24.29647 | 47.63213 | 0.53559 | 11.18743 |
April | 485.00000 | 24.31339 | 47.65229 | 0.53873 | 11.26814 |
May | 508.00000 | 24.33031 | 47.56573 | -0.3102 | 7.39754 |
June | 496.00000 | 24.31872 | 47.52248 | -0.3100 | 7.39404 |
July | 497.00000 | 24.36805 | 47.50480 | -0.3032 | 7.37580 |
August | 514.00000 | 24.33261 | 47.72826 | -0.3138 | 7.50199 |
September | 485.00000 | 24.32488 | 47.81154 | -0.3156 | 7.46412 |
October | 502.00000 | 24.38388 | 47.61385 | 0.55086 | 11.60691 |
November | 489.00000 | 24.38469 | 47.50297 | 0.55196 | 11.61923 |
December | 497.00000 | 24.35117 | 47.48112 | 0.54092 | 11.33521 |
Annual Sum or Average | 5943.00000 | 24.34434 | 47.55405 | 0.18504 | 9.74969 |
Minimum of Months | 454.00000 | 24.29647 | 47.18818 | -0.3156 | 7.37580 |
Maximum of Months | 514.00000 | 24.38731 | 47.81154 | 0.55196 | 11.62780 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 24.20264 | 47.54075 | 0.49475 | 10.31891 |
February | 454.00000 | 24.17282 | 47.73069 | 0.49102 | 10.19646 |
March | 514.00000 | 24.14473 | 48.03427 | 0.48688 | 10.10351 |
April | 485.00000 | 24.16055 | 48.43408 | 0.49383 | 10.26157 |
May | 508.00000 | 24.19355 | 48.49474 | -0.3686 | 8.18193 |
June | 496.00000 | 24.18706 | 48.44310 | -0.3678 | 8.14046 |
July | 497.00000 | 24.18934 | 48.23964 | -0.3774 | 8.37423 |
August | 514.00000 | 24.15043 | 48.68979 | -0.3897 | 8.53682 |
September | 485.00000 | 24.14192 | 48.69413 | -0.3907 | 8.54093 |
October | 502.00000 | 24.18838 | 48.44149 | 0.49466 | 10.32902 |
November | 489.00000 | 24.19755 | 48.28082 | 0.49642 | 10.34390 |
December | 497.00000 | 24.13666 | 48.08444 | 0.47857 | 9.96134 |
Annual Sum or Average | 5943.00000 | 24.17212 | 48.26210 | 0.12501 | 9.43292 |
Minimum of Months | 454.00000 | 24.13666 | 47.54075 | -0.3907 | 8.14046 |
Maximum of Months | 514.00000 | 24.20264 | 48.69413 | 0.49642 | 10.34390 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 24.17112 | 48.29756 | 0.50297 | 10.53035 |
February | 454.00000 | 24.16109 | 48.35235 | 0.50566 | 10.54713 |
March | 514.00000 | 24.16651 | 48.55445 | 0.51156 | 10.65404 |
April | 485.00000 | 24.22327 | 48.46786 | 0.52669 | 10.99748 |
May | 508.00000 | 24.23701 | 48.46923 | -0.3323 | 7.74470 |
June | 496.00000 | 24.23446 | 48.41198 | -0.3286 | 7.65166 |
July | 497.00000 | 24.21219 | 48.59290 | -0.3486 | 7.96540 |
August | 514.00000 | 24.14819 | 48.99346 | -0.3712 | 8.26893 |
September | 485.00000 | 24.16410 | 48.93210 | -0.3621 | 8.16844 |
October | 502.00000 | 24.18486 | 48.89065 | 0.50746 | 10.63680 |
November | 489.00000 | 24.17106 | 48.77166 | 0.50436 | 10.53801 |
December | 497.00000 | 24.08849 | 48.72993 | 0.48085 | 10.05799 |
Annual Sum or Average | 5943.00000 | 24.18026 | 48.62402 | 0.14627 | 9.46936 |
Minimum of Months | 454.00000 | 24.08849 | 48.29756 | -0.3712 | 7.65166 |
Maximum of Months | 514.00000 | 24.23701 | 48.99346 | 0.52669 | 10.99748 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 24.33973 | 48.93147 | 0.56564 | 12.17524 |
February | 454.00000 | 24.37793 | 48.75348 | 0.58366 | 12.66104 |
March | 514.00000 | 24.34832 | 49.34392 | 0.59070 | 12.75538 |
April | 485.00000 | 24.47028 | 49.08255 | 0.62839 | 13.83715 |
May | 508.00000 | 24.50200 | 49.01834 | -0.1656 | 6.99804 |
June | 496.00000 | 24.48597 | 48.74389 | -0.1472 | 6.80807 |
July | 497.00000 | 24.52549 | 48.55076 | -0.1807 | 7.03122 |
August | 514.00000 | 24.35958 | 50.28422 | -0.2404 | 7.14871 |
September | 485.00000 | 24.40299 | 49.44547 | -0.2384 | 7.19168 |
October | 502.00000 | 24.41654 | 49.63603 | 0.58944 | 12.88348 |
November | 489.00000 | 24.37672 | 49.39081 | 0.57803 | 12.49436 |
December | 497.00000 | 24.28110 | 49.37331 | 0.54698 | 11.77295 |
Annual Sum or Average | 5943.00000 | 24.40716 | 49.21901 | 0.25602 | 10.28849 |
Minimum of Months | 454.00000 | 24.28110 | 48.55076 | -0.2404 | 6.80807 |
Maximum of Months | 514.00000 | 24.52549 | 50.28422 | 0.62839 | 13.83715 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 24.43864 | 48.43790 | 0.62224 | 13.75417 |
February | 454.00000 | 24.47869 | 48.20475 | 0.64658 | 14.52351 |
March | 514.00000 | 24.41195 | 48.79817 | 0.64823 | 14.51062 |
April | 485.00000 | 24.52831 | 48.60492 | 0.68259 | 15.58492 |
May | 508.00000 | 24.49657 | 48.99936 | -0.1416 | 7.09962 |
June | 496.00000 | 24.46484 | 48.86026 | -0.1398 | 6.78811 |
July | 497.00000 | 24.49910 | 48.69907 | -0.1722 | 7.03618 |
August | 514.00000 | 24.36577 | 50.12247 | -0.2016 | 7.10506 |
September | 485.00000 | 24.45510 | 49.12102 | -0.1778 | 7.24047 |
October | 502.00000 | 24.44962 | 49.37969 | 0.62475 | 14.00563 |
November | 489.00000 | 24.43794 | 49.07957 | 0.62014 | 13.77348 |
December | 497.00000 | 24.39030 | 48.86634 | 0.60265 | 13.37493 |
Annual Sum or Average | 5943.00000 | 24.45077 | 48.93959 | 0.29780 | 11.20022 |
Minimum of Months | 454.00000 | 24.36577 | 48.20475 | -0.2016 | 6.78811 |
Maximum of Months | 514.00000 | 24.52831 | 50.12247 | 0.68259 | 15.58492 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 24.54774 | 47.76870 | 0.66581 | 15.20315 |
February | 454.00000 | 24.51080 | 47.89144 | 0.65705 | 14.86685 |
March | 514.00000 | 24.39479 | 48.96520 | 0.62042 | 13.64568 |
April | 485.00000 | 24.45968 | 49.14739 | 0.62360 | 13.69605 |
May | 508.00000 | 24.45130 | 49.35821 | -0.2038 | 7.01412 |
June | 496.00000 | 24.42476 | 49.28825 | -0.2086 | 6.93550 |
July | 497.00000 | 24.46286 | 48.94437 | -0.2245 | 7.16328 |
August | 514.00000 | 24.33212 | 50.48879 | -0.2601 | 7.24962 |
September | 485.00000 | 24.41684 | 49.33239 | -0.2258 | 7.15624 |
October | 502.00000 | 24.48702 | 49.15130 | 0.62507 | 13.98494 |
November | 489.00000 | 24.51436 | 48.52144 | 0.64614 | 14.57674 |
December | 497.00000 | 24.52053 | 48.06690 | 0.65344 | 14.95699 |
Annual Sum or Average | 5943.00000 | 24.45942 | 48.92161 | 0.27706 | 11.33779 |
Minimum of Months | 454.00000 | 24.33212 | 47.76870 | -0.2601 | 6.93550 |
Maximum of Months | 514.00000 | 24.54774 | 50.48879 | 0.66581 | 15.20315 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 24.29625 | 48.82463 | 0.59235 | 13.18326 |
February | 454.00000 | 24.33270 | 48.63690 | 0.61372 | 13.69439 |
March | 514.00000 | 24.33172 | 49.11644 | 0.63055 | 14.08579 |
April | 485.00000 | 24.44690 | 48.94382 | 0.66149 | 14.97116 |
May | 508.00000 | 24.41164 | 49.27016 | -0.1733 | 7.20394 |
June | 496.00000 | 24.40183 | 49.14611 | -0.1660 | 7.01850 |
July | 497.00000 | 24.40240 | 49.01559 | -0.2048 | 7.32390 |
August | 514.00000 | 24.28883 | 50.41708 | -0.2308 | 7.44356 |
September | 485.00000 | 24.34026 | 49.49404 | -0.2180 | 7.44720 |
October | 502.00000 | 24.33927 | 49.69141 | 0.59997 | 13.36327 |
November | 489.00000 | 24.30789 | 49.40221 | 0.59229 | 13.08358 |
December | 497.00000 | 24.21916 | 49.31653 | 0.56700 | 12.62360 |
Annual Sum or Average | 5943.00000 | 24.34304 | 49.28037 | 0.26873 | 10.92633 |
Minimum of Months | 454.00000 | 24.21916 | 48.63690 | -0.2308 | 7.01850 |
Maximum of Months | 514.00000 | 24.44690 | 50.41708 | 0.66149 | 14.97116 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 24.37156 | 48.21273 | 0.56344 | 11.91043 |
February | 454.00000 | 24.38707 | 48.24209 | 0.57501 | 12.21408 |
March | 514.00000 | 24.33616 | 48.63516 | 0.57113 | 12.07419 |
April | 485.00000 | 24.42808 | 48.38649 | 0.60101 | 12.89866 |
May | 508.00000 | 24.50549 | 48.04333 | -0.1822 | 6.68028 |
June | 496.00000 | 24.50282 | 47.77514 | -0.1584 | 6.51641 |
July | 497.00000 | 24.55104 | 47.68326 | -0.1787 | 6.63073 |
August | 514.00000 | 24.40512 | 48.86680 | -0.2348 | 6.83575 |
September | 485.00000 | 24.42209 | 48.49214 | -0.2420 | 6.85520 |
October | 502.00000 | 24.44242 | 48.64846 | 0.58631 | 12.57908 |
November | 489.00000 | 24.40670 | 48.49703 | 0.57660 | 12.25657 |
December | 497.00000 | 24.34540 | 48.56025 | 0.55455 | 11.68866 |
Annual Sum or Average | 5943.00000 | 24.42542 | 48.33904 | 0.24950 | 9.90462 |
Minimum of Months | 454.00000 | 24.33616 | 47.68326 | -0.2420 | 6.51641 |
Maximum of Months | 514.00000 | 24.55104 | 48.86680 | 0.60101 | 12.89866 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 24.51177 | 47.70943 | 0.62960 | 13.77019 |
February | 454.00000 | 24.53328 | 47.65665 | 0.64913 | 14.38948 |
March | 514.00000 | 24.45980 | 48.02665 | 0.64342 | 14.19527 |
April | 485.00000 | 24.55278 | 47.84407 | 0.67042 | 15.04667 |
May | 508.00000 | 24.54274 | 48.02611 | -0.1447 | 6.71405 |
June | 496.00000 | 24.50269 | 47.92530 | -0.1447 | 6.47679 |
July | 497.00000 | 24.56412 | 47.81406 | -0.1599 | 6.59222 |
August | 514.00000 | 24.45561 | 48.71715 | -0.1826 | 6.65378 |
September | 485.00000 | 24.52806 | 48.13600 | -0.1652 | 6.73788 |
October | 502.00000 | 24.54044 | 48.33629 | 0.63538 | 14.06914 |
November | 489.00000 | 24.52446 | 48.14040 | 0.63105 | 13.85920 |
December | 497.00000 | 24.49552 | 48.05832 | 0.61937 | 13.54025 |
Annual Sum or Average | 5943.00000 | 24.51711 | 48.03721 | 0.30342 | 10.97027 |
Minimum of Months | 454.00000 | 24.45561 | 47.65665 | -0.1826 | 6.47679 |
Maximum of Months | 514.00000 | 24.56412 | 48.71715 | 0.67042 | 15.04667 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 24.89670 | 52.48271 | 0.77290 | 18.35278 |
February | 454.00000 | 24.88910 | 52.57867 | 0.76701 | 18.14033 |
March | 514.00000 | 24.65449 | 55.02293 | 0.70770 | 16.07576 |
April | 485.00000 | 24.59689 | 57.12069 | 0.69539 | 15.64059 |
May | 508.00000 | 24.63185 | 60.00421 | -0.0886 | 6.14732 |
June | 496.00000 | 24.61871 | 60.04103 | -0.0879 | 6.16005 |
July | 497.00000 | 24.57395 | 56.95866 | -0.1369 | 6.13212 |
August | 514.00000 | 24.49148 | 61.70803 | -0.1333 | 6.15700 |
September | 485.00000 | 24.56591 | 59.17228 | -0.1155 | 6.11510 |
October | 502.00000 | 24.65947 | 58.72386 | 0.72869 | 16.75185 |
November | 489.00000 | 24.78574 | 56.21643 | 0.75940 | 17.80863 |
December | 497.00000 | 24.83533 | 53.02778 | 0.75820 | 17.91233 |
Annual Sum or Average | 5943.00000 | 24.68153 | 56.96009 | 0.38196 | 12.56505 |
Minimum of Months | 454.00000 | 24.49148 | 52.48271 | -0.1369 | 6.11510 |
Maximum of Months | 514.00000 | 24.89670 | 61.70803 | 0.77290 | 18.35278 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 24.48061 | 47.82594 | 0.62096 | 13.59355 |
February | 454.00000 | 24.48584 | 47.83740 | 0.63551 | 13.98772 |
March | 514.00000 | 24.44175 | 48.16335 | 0.63806 | 14.03992 |
April | 485.00000 | 24.52506 | 48.03206 | 0.66061 | 14.73073 |
May | 508.00000 | 24.51237 | 48.17260 | -0.1601 | 6.66444 |
June | 496.00000 | 24.48713 | 48.07736 | -0.1558 | 6.55197 |
July | 497.00000 | 24.54650 | 47.93700 | -0.1696 | 6.63807 |
August | 514.00000 | 24.44424 | 48.85779 | -0.1924 | 6.71137 |
September | 485.00000 | 24.48936 | 48.32214 | -0.1836 | 6.70258 |
October | 502.00000 | 24.51876 | 48.45143 | 0.62847 | 13.84784 |
November | 489.00000 | 24.48467 | 48.26357 | 0.62067 | 13.55049 |
December | 497.00000 | 24.44973 | 48.20306 | 0.60774 | 13.24331 |
Annual Sum or Average | 5943.00000 | 24.48859 | 48.18284 | 0.29257 | 10.82448 |
Minimum of Months | 454.00000 | 24.44175 | 47.82594 | -0.1924 | 6.55197 |
Maximum of Months | 514.00000 | 24.54650 | 48.85779 | 0.66061 | 14.73073 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 24.36318 | 47.99951 | 0.55392 | 11.72926 |
February | 454.00000 | 24.38839 | 47.95678 | 0.56675 | 12.07557 |
March | 514.00000 | 24.34268 | 48.57442 | 0.56692 | 12.03158 |
April | 485.00000 | 24.43716 | 48.76433 | 0.59865 | 12.91578 |
May | 508.00000 | 24.49320 | 48.73757 | -0.1965 | 6.95379 |
June | 496.00000 | 24.47421 | 48.44635 | -0.1818 | 6.79529 |
July | 497.00000 | 24.52153 | 48.02036 | -0.2080 | 6.95706 |
August | 514.00000 | 24.36943 | 49.66635 | -0.2607 | 7.16562 |
September | 485.00000 | 24.39518 | 48.99125 | -0.2653 | 7.17250 |
October | 502.00000 | 24.42632 | 49.00004 | 0.57593 | 12.39942 |
November | 489.00000 | 24.39326 | 48.75512 | 0.56639 | 12.07355 |
December | 497.00000 | 24.32123 | 48.59265 | 0.54138 | 11.43315 |
Annual Sum or Average | 5943.00000 | 24.41045 | 48.63190 | 0.23493 | 9.95322 |
Minimum of Months | 454.00000 | 24.32123 | 47.95678 | -0.2653 | 6.79529 |
Maximum of Months | 514.00000 | 24.52153 | 49.66635 | 0.59865 | 12.91578 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 427.00000 | 24.52893 | 47.24424 | 0.60938 | 13.36939 |
February | 385.00000 | 24.57006 | 47.14028 | 0.63120 | 14.06885 |
March | 433.00000 | 24.49039 | 47.83458 | 0.62539 | 13.88001 |
April | 410.00000 | 24.60256 | 48.12920 | 0.65946 | 14.92425 |
May | 430.00000 | 24.58077 | 48.61295 | -0.1640 | 7.21124 |
June | 418.00000 | 24.53332 | 48.50982 | -0.1700 | 6.93679 |
July | 422.00000 | 24.57999 | 47.96847 | -0.1931 | 7.09025 |
August | 433.00000 | 24.44894 | 49.49189 | -0.2206 | 7.27514 |
September | 410.00000 | 24.53864 | 48.46634 | -0.1985 | 7.32750 |
October | 427.00000 | 24.54481 | 48.56130 | 0.61511 | 13.72033 |
November | 417.00000 | 24.53069 | 48.26398 | 0.61103 | 13.48872 |
December | 422.00000 | 24.48880 | 47.87324 | 0.59567 | 13.10663 |
Annual Sum or Average | 5034.00000 | 24.53587 | 48.18364 | 0.28073 | 11.00825 |
Minimum of Months | 385.00000 | 24.44894 | 47.14028 | -0.2206 | 6.93679 |
Maximum of Months | 433.00000 | 24.60256 | 49.49189 | 0.65946 | 14.92425 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 24.60848 | 46.72402 | 0.65770 | 14.83912 |
February | 454.00000 | 24.55017 | 47.00036 | 0.64300 | 14.34418 |
March | 514.00000 | 24.39954 | 48.15587 | 0.59730 | 12.92189 |
April | 485.00000 | 24.42604 | 48.82899 | 0.59409 | 12.78580 |
May | 508.00000 | 24.43477 | 49.10460 | -0.2353 | 7.01864 |
June | 496.00000 | 24.39835 | 49.03534 | -0.2443 | 6.98376 |
July | 497.00000 | 24.45346 | 48.43186 | -0.2516 | 7.12332 |
August | 514.00000 | 24.34056 | 49.87446 | -0.2798 | 7.27532 |
September | 485.00000 | 24.41272 | 48.86447 | -0.2524 | 7.11089 |
October | 502.00000 | 24.50745 | 48.48487 | 0.61222 | 13.50928 |
November | 489.00000 | 24.55087 | 47.83082 | 0.63579 | 14.17390 |
December | 497.00000 | 24.59460 | 47.19000 | 0.65067 | 14.71106 |
Annual Sum or Average | 5943.00000 | 24.47214 | 48.30590 | 0.25692 | 11.03593 |
Minimum of Months | 454.00000 | 24.34056 | 46.72402 | -0.2798 | 6.98376 |
Maximum of Months | 514.00000 | 24.60848 | 49.87446 | 0.65770 | 14.83912 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 24.39085 | 47.77248 | 0.59232 | 12.94302 |
February | 454.00000 | 24.40330 | 47.72304 | 0.60662 | 13.28594 |
March | 514.00000 | 24.37694 | 48.24608 | 0.61483 | 13.48699 |
April | 485.00000 | 24.46469 | 48.53346 | 0.64059 | 14.23169 |
May | 508.00000 | 24.44189 | 48.96161 | -0.1931 | 7.01480 |
June | 496.00000 | 24.41774 | 48.83482 | -0.1916 | 6.88849 |
July | 497.00000 | 24.45028 | 48.39902 | -0.2178 | 7.08538 |
August | 514.00000 | 24.34795 | 49.74042 | -0.2379 | 7.20859 |
September | 485.00000 | 24.39082 | 48.93360 | -0.2305 | 7.18964 |
October | 502.00000 | 24.41337 | 48.94343 | 0.59772 | 13.11356 |
November | 489.00000 | 24.39019 | 48.65801 | 0.59190 | 12.88509 |
December | 497.00000 | 24.33447 | 48.41147 | 0.57406 | 12.49784 |
Annual Sum or Average | 5943.00000 | 24.40162 | 48.60464 | 0.25893 | 10.62645 |
Minimum of Months | 454.00000 | 24.33447 | 47.72304 | -0.2379 | 6.88849 |
Maximum of Months | 514.00000 | 24.46469 | 49.74042 | 0.64059 | 14.23169 |
Report: DXReportMonthly
For: PACU_VAV_BOT COOLING COIL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.960654E+11 | 0.243738E+11 | 454.31 | 0.647008E+11 | 0.313646E+11 | 0.00 | 1.00 | 01-JAN-01:23 | 0.00 | 01-JAN-00:03 | 108606.96 | 09-JAN-05:02 | 76525.22 | 02-JAN-07:03 | 33400.51 | 10-JAN-13:03 | 24977.55 | 09-JAN-05:02 | 0.00 |
February | 0.904219E+11 | 0.232887E+11 | 412.51 | 0.610041E+11 | 0.294178E+11 | 0.00 | 1.00 | 01-FEB-05:03 | 0.00 | 01-FEB-00:10 | 105196.27 | 06-FEB-05:02 | 78900.63 | 21-FEB-05:02 | 34837.87 | 15-FEB-08:65 | 26753.63 | 15-FEB-13:13 | 0.00 |
March | 0.109718E+12 | 0.285922E+11 | 475.26 | 0.722640E+11 | 0.374542E+11 | 0.00 | 1.00 | 01-MAR-05:03 | 0.00 | 01-MAR-00:10 | 112254.34 | 28-MAR-04:03 | 79674.22 | 20-MAR-04:02 | 38548.60 | 28-MAR-07:10 | 27419.40 | 28-MAR-04:03 | 0.00 |
April | 0.114202E+12 | 0.295669E+11 | 450.19 | 0.686568E+11 | 0.455448E+11 | 0.00 | 1.00 | 01-APR-04:03 | 0.00 | 01-APR-00:10 | 113000.80 | 29-APR-05:03 | 79312.52 | 17-APR-04:02 | 44401.68 | 10-APR-17:00 | 28528.06 | 10-APR-13:00 | 0.00 |
May | 0.131386E+12 | 0.336855E+11 | 477.21 | 0.734080E+11 | 0.579783E+11 | 0.00 | 1.00 | 01-MAY-00:42 | 0.00 | 01-MAY-00:05 | 126692.82 | 22-MAY-04:02 | 80352.02 | 01-MAY-04:02 | 52335.29 | 30-MAY-07:03 | 31826.76 | 04-MAY-13:00 | 0.00 |
June | 0.132325E+12 | 0.340704E+11 | 464.00 | 0.743917E+11 | 0.579332E+11 | 0.00 | 1.00 | 01-JUN-04:03 | 0.00 | 01-JUN-00:10 | 123164.65 | 13-JUN-04:02 | 78986.04 | 12-JUN-04:02 | 50427.60 | 14-JUN-07:05 | 32356.18 | 15-JUN-13:00 | 0.00 |
July | 0.105765E+12 | 0.263823E+11 | 451.50 | 0.642401E+11 | 0.415247E+11 | 0.00 | 1.00 | 01-JUL-04:03 | 0.00 | 01-JUL-00:10 | 108954.20 | 24-JUL-04:02 | 78942.77 | 24-JUL-04:02 | 38412.80 | 03-JUL-12:00 | 26343.09 | 17-JUL-13:00 | 0.00 |
August | 0.124426E+12 | 0.309678E+11 | 467.06 | 0.682793E+11 | 0.561466E+11 | 0.00 | 1.00 | 01-AUG-04:03 | 0.00 | 01-AUG-00:10 | 126753.96 | 21-AUG-04:02 | 79582.03 | 02-AUG-04:03 | 51514.44 | 21-AUG-04:02 | 29711.93 | 15-AUG-12:03 | 0.00 |
September | 0.113150E+12 | 0.281674E+11 | 444.69 | 0.631435E+11 | 0.500064E+11 | 0.00 | 1.00 | 01-SEP-04:03 | 0.00 | 01-SEP-00:10 | 114648.96 | 25-SEP-04:02 | 78457.13 | 11-SEP-04:02 | 44671.88 | 25-SEP-12:02 | 28692.19 | 05-SEP-12:03 | 0.00 |
October | 0.109448E+12 | 0.269118E+11 | 443.57 | 0.617814E+11 | 0.476668E+11 | 0.00 | 1.00 | 01-OCT-06:23 | 0.00 | 01-OCT-00:10 | 115437.24 | 30-OCT-04:02 | 78583.53 | 16-OCT-04:02 | 44094.72 | 16-OCT-12:03 | 26921.92 | 30-OCT-04:02 | 0.00 |
November | 0.102340E+12 | 0.254011E+11 | 431.56 | 0.615845E+11 | 0.407552E+11 | 0.00 | 1.00 | 01-NOV-04:03 | 0.00 | 01-NOV-00:10 | 113664.31 | 13-NOV-07:03 | 79200.31 | 13-NOV-07:03 | 44230.42 | 10-NOV-13:02 | 27219.72 | 13-NOV-07:03 | 0.00 |
December | 0.942465E+11 | 0.235651E+11 | 445.32 | 0.607538E+11 | 0.334928E+11 | 0.00 | 1.00 | 01-DEC-05:03 | 0.00 | 01-DEC-00:10 | 103849.71 | 11-DEC-05:02 | 75065.96 | 26-DEC-05:02 | 36919.02 | 12-DEC-18:00 | 25468.03 | 11-DEC-13:02 | 0.00 |
Annual Sum or Average | 0.132349E+13 | 0.334973E+12 | 5417.18 | 0.794208E+12 | 0.529285E+12 | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 0.904219E+11 | 0.232887E+11 | 412.51 | 0.607538E+11 | 0.294178E+11 | 0.00 | 1.00 | 0.00 | 103849.71 | 75065.96 | 33400.51 | 24977.55 | 0.00 | ||||||
Maximum of Months | 0.132325E+12 | 0.340704E+11 | 477.21 | 0.743917E+11 | 0.579783E+11 | 0.00 | 1.00 | 0.00 | 126753.96 | 80352.02 | 52335.29 | 32356.18 | 0.00 |
Report: DXReportMonthly
For: PACU_VAV_MID COOLING COIL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.668333E+11 | 0.172171E+11 | 438.61 | 0.498429E+11 | 0.169904E+11 | 0.00 | 1.00 | 01-JAN-06:23 | 0.00 | 01-JAN-00:03 | 93860.64 | 09-JAN-05:02 | 65308.02 | 02-JAN-05:02 | 35878.82 | 02-JAN-05:04 | 21568.74 | 09-JAN-05:02 | 0.00 |
February | 0.626716E+11 | 0.164554E+11 | 403.63 | 0.470271E+11 | 0.156445E+11 | 0.00 | 1.00 | 01-FEB-05:03 | 0.00 | 01-FEB-00:10 | 89940.32 | 06-FEB-05:02 | 66289.70 | 21-FEB-05:02 | 27341.55 | 06-FEB-05:02 | 20637.16 | 06-FEB-05:02 | 0.00 |
March | 0.736525E+11 | 0.196535E+11 | 466.68 | 0.548840E+11 | 0.187685E+11 | 0.00 | 1.00 | 01-MAR-05:03 | 0.00 | 01-MAR-00:10 | 100398.95 | 27-MAR-04:02 | 67231.72 | 20-MAR-04:02 | 34034.29 | 27-MAR-04:02 | 23860.10 | 27-MAR-04:02 | 0.00 |
April | 0.730702E+11 | 0.195484E+11 | 445.31 | 0.518980E+11 | 0.211722E+11 | 0.00 | 1.00 | 01-APR-05:03 | 0.00 | 01-APR-00:10 | 96755.47 | 10-APR-04:02 | 66881.58 | 03-APR-04:02 | 32185.15 | 10-APR-04:02 | 22698.08 | 10-APR-04:02 | 0.00 |
May | 0.823433E+11 | 0.218528E+11 | 468.35 | 0.551435E+11 | 0.271999E+11 | 0.00 | 1.00 | 01-MAY-00:33 | 0.00 | 01-MAY-00:05 | 105559.15 | 22-MAY-04:02 | 67812.16 | 08-MAY-04:02 | 40338.51 | 22-MAY-04:02 | 25353.59 | 22-MAY-04:02 | 0.00 |
June | 0.828892E+11 | 0.220755E+11 | 456.66 | 0.558433E+11 | 0.270459E+11 | 0.00 | 1.00 | 01-JUN-04:03 | 0.00 | 01-JUN-00:10 | 105393.76 | 12-JUN-04:02 | 67910.52 | 19-JUN-04:02 | 39904.04 | 12-JUN-04:04 | 25058.21 | 12-JUN-04:02 | 0.00 |
July | 0.706138E+11 | 0.179248E+11 | 439.97 | 0.485894E+11 | 0.220245E+11 | 0.00 | 1.00 | 01-JUL-05:03 | 0.00 | 01-JUL-00:10 | 96075.61 | 24-JUL-04:02 | 65854.32 | 24-JUL-04:02 | 31067.25 | 24-JUL-04:04 | 22751.26 | 24-JUL-04:02 | 0.00 |
August | 0.771222E+11 | 0.197571E+11 | 455.69 | 0.507493E+11 | 0.263729E+11 | 0.00 | 1.00 | 01-AUG-04:03 | 0.00 | 01-AUG-00:10 | 105995.12 | 21-AUG-05:03 | 66665.28 | 14-AUG-04:02 | 49210.38 | 21-AUG-05:03 | 25004.54 | 14-AUG-04:02 | 0.00 |
September | 0.713434E+11 | 0.182706E+11 | 432.92 | 0.473954E+11 | 0.239480E+11 | 0.00 | 1.00 | 01-SEP-05:03 | 0.00 | 01-SEP-00:10 | 103723.23 | 25-SEP-04:02 | 67740.93 | 05-SEP-04:02 | 38405.99 | 25-SEP-04:02 | 24578.70 | 25-SEP-04:02 | 0.00 |
October | 0.711869E+11 | 0.179127E+11 | 435.99 | 0.472775E+11 | 0.239095E+11 | 0.00 | 1.00 | 01-OCT-06:27 | 0.00 | 01-OCT-00:10 | 103596.91 | 30-OCT-04:02 | 65920.36 | 16-OCT-04:02 | 38810.43 | 30-OCT-04:02 | 24073.44 | 30-OCT-04:02 | 0.00 |
November | 0.675690E+11 | 0.171141E+11 | 419.99 | 0.470949E+11 | 0.204741E+11 | 0.00 | 1.00 | 01-NOV-05:03 | 0.00 | 01-NOV-00:10 | 100089.67 | 13-NOV-05:02 | 65575.67 | 13-NOV-07:03 | 36104.88 | 13-NOV-05:04 | 23365.23 | 13-NOV-05:02 | 0.00 |
December | 0.644455E+11 | 0.163971E+11 | 428.72 | 0.466362E+11 | 0.178093E+11 | 0.00 | 1.00 | 01-DEC-06:03 | 0.00 | 01-DEC-00:10 | 88210.83 | 11-DEC-05:02 | 62446.39 | 26-DEC-05:02 | 29852.45 | 11-DEC-05:02 | 20227.23 | 11-DEC-05:02 | 0.00 |
Annual Sum or Average | 0.863741E+12 | 0.224179E+12 | 5292.51 | 0.602381E+12 | 0.261360E+12 | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 0.626716E+11 | 0.163971E+11 | 403.63 | 0.466362E+11 | 0.156445E+11 | 0.00 | 1.00 | 0.00 | 88210.83 | 62446.39 | 27341.55 | 20227.23 | 0.00 | ||||||
Maximum of Months | 0.828892E+11 | 0.220755E+11 | 468.35 | 0.558433E+11 | 0.271999E+11 | 0.00 | 1.00 | 0.00 | 105995.12 | 67910.52 | 49210.38 | 25353.59 | 0.00 |
Report: DXReportMonthly
For: PACU_VAV_TOP COOLING COIL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.873293E+11 | 0.221952E+11 | 436.28 | 0.587884E+11 | 0.285409E+11 | 0.00 | 1.00 | 01-JAN-07:53 | 0.00 | 01-JAN-00:03 | 104024.20 | 02-JAN-05:02 | 73415.66 | 02-JAN-05:02 | 33122.33 | 09-JAN-05:02 | 24410.98 | 04-JAN-14:40 | 0.00 |
February | 0.843344E+11 | 0.217470E+11 | 402.60 | 0.568905E+11 | 0.274439E+11 | 0.00 | 1.00 | 01-FEB-06:03 | 0.00 | 01-FEB-00:10 | 98729.72 | 26-FEB-15:52 | 73628.30 | 21-FEB-14:40 | 30790.22 | 05-FEB-14:02 | 27510.03 | 13-FEB-15:00 | 0.00 |
March | 0.103022E+12 | 0.268182E+11 | 467.07 | 0.681914E+11 | 0.348310E+11 | 0.00 | 1.00 | 01-MAR-06:03 | 0.00 | 01-MAR-00:10 | 117842.97 | 20-MAR-04:02 | 79812.94 | 20-MAR-04:02 | 39160.39 | 27-MAR-04:02 | 30023.12 | 19-MAR-15:32 | 0.00 |
April | 0.109308E+12 | 0.281568E+11 | 449.83 | 0.658796E+11 | 0.434288E+11 | 0.00 | 1.00 | 01-APR-05:03 | 0.00 | 01-APR-00:10 | 118616.50 | 02-APR-15:42 | 80637.08 | 17-APR-04:02 | 42486.80 | 30-APR-16:12 | 31731.84 | 02-APR-15:42 | 0.00 |
May | 0.123226E+12 | 0.314706E+11 | 472.03 | 0.687555E+11 | 0.544706E+11 | 0.00 | 1.00 | 01-MAY-00:53 | 0.00 | 01-MAY-00:05 | 130084.09 | 22-MAY-04:02 | 80847.37 | 08-MAY-04:02 | 56267.46 | 22-MAY-04:02 | 33415.31 | 29-MAY-13:02 | 0.00 |
June | 0.124218E+12 | 0.318138E+11 | 459.79 | 0.697534E+11 | 0.544647E+11 | 0.00 | 1.00 | 01-JUN-05:03 | 0.00 | 01-JUN-00:10 | 126058.06 | 13-JUN-04:02 | 80647.44 | 19-JUN-04:02 | 50782.16 | 13-JUN-04:02 | 34043.30 | 11-JUN-14:32 | 0.00 |
July | 0.971975E+11 | 0.241551E+11 | 445.35 | 0.582700E+11 | 0.389275E+11 | 0.00 | 1.00 | 01-JUL-05:03 | 0.00 | 01-JUL-00:10 | 110109.58 | 10-JUL-04:02 | 77860.02 | 31-JUL-04:02 | 36233.20 | 02-JUL-12:02 | 27432.66 | 30-JUL-14:53 | 0.00 |
August | 0.112907E+12 | 0.279262E+11 | 456.42 | 0.609036E+11 | 0.520031E+11 | 0.00 | 1.00 | 01-AUG-05:03 | 0.00 | 01-AUG-00:10 | 130279.09 | 13-AUG-13:32 | 79092.48 | 14-AUG-04:02 | 51538.65 | 13-AUG-13:32 | 34758.88 | 13-AUG-13:32 | 0.00 |
September | 0.104208E+12 | 0.258084E+11 | 436.89 | 0.574937E+11 | 0.467142E+11 | 0.00 | 1.00 | 01-SEP-05:03 | 0.00 | 01-SEP-00:10 | 122976.75 | 04-SEP-13:23 | 79796.74 | 05-SEP-04:02 | 48792.58 | 30-SEP-11:00 | 31715.05 | 04-SEP-13:23 | 0.00 |
October | 0.997182E+11 | 0.243975E+11 | 437.61 | 0.553112E+11 | 0.444070E+11 | 0.00 | 1.00 | 01-OCT-06:27 | 0.00 | 01-OCT-00:10 | 114541.93 | 30-OCT-04:02 | 76327.86 | 16-OCT-04:02 | 41776.36 | 30-OCT-04:02 | 26670.45 | 30-OCT-04:02 | 0.00 |
November | 0.925426E+11 | 0.229040E+11 | 419.75 | 0.551503E+11 | 0.373923E+11 | 0.00 | 1.00 | 01-NOV-05:03 | 0.00 | 01-NOV-00:10 | 104750.29 | 13-NOV-05:02 | 68521.27 | 13-NOV-05:02 | 38907.36 | 11-NOV-14:32 | 26539.93 | 11-NOV-14:32 | 0.00 |
December | 0.856935E+11 | 0.214314E+11 | 430.08 | 0.548406E+11 | 0.308529E+11 | 0.00 | 1.00 | 01-DEC-08:65 | 0.00 | 01-DEC-00:10 | 89290.06 | 10-DEC-16:23 | 66710.78 | 26-DEC-15:00 | 33243.48 | 10-DEC-17:43 | 23801.10 | 12-DEC-14:00 | 0.00 |
Annual Sum or Average | 0.122371E+13 | 0.308824E+12 | 5313.70 | 0.730228E+12 | 0.493477E+12 | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 0.843344E+11 | 0.214314E+11 | 402.60 | 0.548406E+11 | 0.274439E+11 | 0.00 | 1.00 | 0.00 | 89290.06 | 66710.78 | 30790.22 | 23801.10 | 0.00 | ||||||
Maximum of Months | 0.124218E+12 | 0.318138E+11 | 472.03 | 0.697534E+11 | 0.544706E+11 | 0.00 | 1.00 | 0.00 | 130279.09 | 80847.37 | 56267.46 | 34758.88 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 393.48 | 0.00 | 393.48 | 863.54 | 182.28 | 0.00 | 0.00 | 0.00 |
February | 419.73 | 0.00 | 419.73 | 965.67 | 137.76 | 0.00 | 0.00 | 0.00 |
March | 430.77 | 0.00 | 430.77 | 1049.43 | 91.61 | 0.00 | 0.00 | 0.00 |
April | 468.79 | 6.64 | 462.15 | 1176.13 | 39.79 | 0.00 | 0.00 | 0.00 |
May | 600.94 | 64.02 | 536.92 | 1501.37 | 49.18 | 0.00 | 0.00 | 0.00 |
June | 734.07 | 148.35 | 585.72 | 1784.44 | 56.39 | 0.00 | 0.00 | 0.00 |
July | 631.23 | 66.16 | 565.06 | 1403.52 | 100.59 | 0.00 | 0.00 | 0.00 |
August | 519.71 | 22.16 | 497.55 | 1175.08 | 74.02 | 0.00 | 0.00 | 0.00 |
September | 442.47 | 0.21 | 442.26 | 1030.98 | 74.63 | 0.00 | 0.00 | 0.00 |
October | 426.34 | 0.00 | 426.34 | 921.32 | 98.67 | 0.00 | 0.00 | 0.00 |
November | 403.41 | 0.00 | 403.41 | 880.03 | 120.87 | 0.00 | 0.00 | 0.00 |
December | 382.26 | 0.00 | 382.26 | 832.84 | 197.90 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 488.06 | 25.70 | 462.36 | 1132.46 | 102.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 382.26 | 0.00 | 382.26 | 832.84 | 39.79 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 734.07 | 148.35 | 585.72 | 1784.44 | 197.90 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 505.82 | 170.47 | 335.34 | 1022.76 | 115.95 | 0.00 | 0.00 | 0.00 |
February | 573.59 | 210.31 | 363.29 | 1186.05 | 86.25 | 0.00 | 0.00 | 0.00 |
March | 625.33 | 244.87 | 380.45 | 1324.15 | 56.08 | 0.00 | 0.00 | 0.00 |
April | 631.99 | 241.44 | 390.54 | 1373.79 | 24.91 | 0.00 | 0.00 | 0.00 |
May | 543.25 | 164.44 | 378.81 | 1229.74 | 31.72 | 0.00 | 0.00 | 0.00 |
June | 578.61 | 190.56 | 388.04 | 1292.45 | 35.50 | 0.00 | 0.00 | 0.00 |
July | 494.21 | 110.71 | 383.49 | 1039.27 | 64.70 | 0.00 | 0.00 | 0.00 |
August | 543.89 | 159.88 | 384.01 | 1128.42 | 48.69 | 0.00 | 0.00 | 0.00 |
September | 510.78 | 139.19 | 371.59 | 1087.19 | 50.31 | 0.00 | 0.00 | 0.00 |
October | 478.71 | 122.47 | 356.24 | 971.00 | 66.25 | 0.00 | 0.00 | 0.00 |
November | 463.30 | 128.03 | 335.27 | 944.57 | 80.66 | 0.00 | 0.00 | 0.00 |
December | 474.11 | 152.15 | 321.96 | 955.14 | 128.03 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 534.86 | 169.15 | 365.71 | 1128.59 | 65.78 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 463.30 | 110.71 | 321.96 | 944.57 | 24.91 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 631.99 | 244.87 | 390.54 | 1373.79 | 128.03 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 1041.77 | 434.64 | 607.13 | 2127.11 | 186.94 | 0.00 | 0.00 | 0.00 |
February | 884.62 | 288.42 | 596.20 | 1943.10 | 137.31 | 0.00 | 0.00 | 0.00 |
March | 603.70 | 81.08 | 522.62 | 1465.24 | 86.93 | 0.00 | 0.00 | 0.00 |
April | 450.09 | 0.20 | 449.89 | 1144.84 | 35.40 | 0.00 | 0.00 | 0.00 |
May | 450.40 | 0.00 | 450.40 | 1174.88 | 44.93 | 0.00 | 0.00 | 0.00 |
June | 448.78 | 0.00 | 448.78 | 1166.89 | 49.64 | 0.00 | 0.00 | 0.00 |
July | 462.31 | 0.00 | 462.31 | 1042.58 | 94.71 | 0.00 | 0.00 | 0.00 |
August | 450.06 | 0.70 | 449.36 | 1024.43 | 67.86 | 0.00 | 0.00 | 0.00 |
September | 498.25 | 16.27 | 481.97 | 1154.90 | 74.80 | 0.00 | 0.00 | 0.00 |
October | 651.85 | 103.93 | 547.92 | 1389.87 | 104.53 | 0.00 | 0.00 | 0.00 |
November | 847.62 | 258.60 | 589.02 | 1759.49 | 130.06 | 0.00 | 0.00 | 0.00 |
December | 1041.23 | 443.00 | 598.23 | 2095.65 | 207.55 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 651.65 | 135.05 | 516.60 | 1455.08 | 101.75 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 448.78 | 0.00 | 448.78 | 1024.43 | 35.40 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1041.77 | 443.00 | 607.13 | 2127.11 | 207.55 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 512.50 | 180.21 | 332.29 | 1050.72 | 128.34 | 0.00 | 0.00 | 0.00 |
February | 562.87 | 199.19 | 363.69 | 1179.01 | 96.89 | 0.00 | 0.00 | 0.00 |
March | 630.94 | 249.21 | 381.73 | 1344.08 | 69.21 | 0.00 | 0.00 | 0.00 |
April | 634.06 | 242.85 | 391.21 | 1369.95 | 30.70 | 0.00 | 0.00 | 0.00 |
May | 539.52 | 159.83 | 379.68 | 1215.70 | 31.85 | 0.00 | 0.00 | 0.00 |
June | 584.63 | 201.51 | 383.12 | 1296.65 | 36.25 | 0.00 | 0.00 | 0.00 |
July | 498.43 | 117.54 | 380.89 | 1047.60 | 66.46 | 0.00 | 0.00 | 0.00 |
August | 541.89 | 160.48 | 381.41 | 1119.39 | 49.62 | 0.00 | 0.00 | 0.00 |
September | 507.56 | 140.77 | 366.79 | 1077.28 | 52.57 | 0.00 | 0.00 | 0.00 |
October | 476.70 | 122.88 | 353.82 | 968.01 | 69.32 | 0.00 | 0.00 | 0.00 |
November | 464.88 | 126.79 | 338.09 | 952.78 | 84.55 | 0.00 | 0.00 | 0.00 |
December | 475.77 | 155.63 | 320.14 | 975.61 | 137.97 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 535.46 | 171.11 | 364.35 | 1132.24 | 71.15 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 464.88 | 117.54 | 320.14 | 952.78 | 30.70 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 634.06 | 249.21 | 391.21 | 1369.95 | 137.97 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 131.15 | 0.00 | 131.15 | 289.58 | 63.70 | 0.00 | 0.00 | 0.00 |
February | 139.90 | 0.00 | 139.90 | 324.44 | 48.96 | 0.00 | 0.00 | 0.00 |
March | 143.58 | 0.00 | 143.58 | 353.02 | 31.78 | 0.00 | 0.00 | 0.00 |
April | 156.26 | 2.21 | 154.04 | 396.34 | 13.59 | 0.00 | 0.00 | 0.00 |
May | 200.30 | 21.34 | 178.97 | 503.97 | 18.14 | 0.00 | 0.00 | 0.00 |
June | 244.68 | 49.45 | 195.23 | 597.67 | 20.98 | 0.00 | 0.00 | 0.00 |
July | 210.40 | 22.05 | 188.35 | 470.64 | 37.19 | 0.00 | 0.00 | 0.00 |
August | 173.23 | 7.39 | 165.84 | 392.37 | 28.51 | 0.00 | 0.00 | 0.00 |
September | 147.48 | 0.07 | 147.41 | 345.42 | 27.52 | 0.00 | 0.00 | 0.00 |
October | 142.11 | 0.00 | 142.11 | 309.12 | 35.67 | 0.00 | 0.00 | 0.00 |
November | 134.46 | 0.00 | 134.46 | 295.17 | 44.03 | 0.00 | 0.00 | 0.00 |
December | 127.41 | 0.00 | 127.41 | 278.50 | 71.18 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 162.68 | 8.56 | 154.11 | 379.82 | 36.78 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 127.41 | 0.00 | 127.41 | 278.50 | 13.59 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 244.68 | 49.45 | 195.23 | 597.67 | 71.18 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 131.16 | 0.00 | 131.16 | 289.60 | 63.70 | 0.00 | 0.00 | 0.00 |
February | 139.91 | 0.00 | 139.91 | 324.46 | 48.96 | 0.00 | 0.00 | 0.00 |
March | 143.59 | 0.00 | 143.59 | 353.04 | 31.78 | 0.00 | 0.00 | 0.00 |
April | 156.27 | 2.21 | 154.05 | 396.37 | 13.59 | 0.00 | 0.00 | 0.00 |
May | 200.32 | 21.34 | 178.98 | 504.00 | 18.14 | 0.00 | 0.00 | 0.00 |
June | 244.69 | 49.45 | 195.24 | 597.71 | 20.98 | 0.00 | 0.00 | 0.00 |
July | 210.41 | 22.06 | 188.36 | 470.67 | 37.20 | 0.00 | 0.00 | 0.00 |
August | 173.24 | 7.39 | 165.85 | 392.39 | 28.52 | 0.00 | 0.00 | 0.00 |
September | 147.49 | 0.07 | 147.42 | 345.44 | 27.52 | 0.00 | 0.00 | 0.00 |
October | 142.12 | 0.00 | 142.12 | 309.14 | 35.68 | 0.00 | 0.00 | 0.00 |
November | 134.47 | 0.00 | 134.47 | 295.19 | 44.03 | 0.00 | 0.00 | 0.00 |
December | 127.42 | 0.00 | 127.42 | 278.52 | 71.19 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 162.69 | 8.57 | 154.12 | 379.85 | 36.79 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 127.42 | 0.00 | 127.42 | 278.52 | 13.59 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 244.69 | 49.45 | 195.24 | 597.71 | 71.19 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 131.16 | 0.00 | 131.16 | 289.60 | 63.70 | 0.00 | 0.00 | 0.00 |
February | 139.91 | 0.00 | 139.91 | 324.46 | 48.96 | 0.00 | 0.00 | 0.00 |
March | 143.59 | 0.00 | 143.59 | 353.04 | 31.78 | 0.00 | 0.00 | 0.00 |
April | 156.27 | 2.21 | 154.05 | 396.37 | 13.59 | 0.00 | 0.00 | 0.00 |
May | 200.32 | 21.34 | 178.98 | 504.00 | 18.14 | 0.00 | 0.00 | 0.00 |
June | 244.69 | 49.45 | 195.24 | 597.71 | 20.98 | 0.00 | 0.00 | 0.00 |
July | 210.41 | 22.06 | 188.36 | 470.67 | 37.20 | 0.00 | 0.00 | 0.00 |
August | 173.24 | 7.39 | 165.85 | 392.39 | 28.52 | 0.00 | 0.00 | 0.00 |
September | 147.49 | 0.07 | 147.42 | 345.44 | 27.52 | 0.00 | 0.00 | 0.00 |
October | 142.12 | 0.00 | 142.12 | 309.14 | 35.68 | 0.00 | 0.00 | 0.00 |
November | 134.47 | 0.00 | 134.47 | 295.19 | 44.03 | 0.00 | 0.00 | 0.00 |
December | 127.42 | 0.00 | 127.42 | 278.52 | 71.19 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 162.69 | 8.57 | 154.12 | 379.85 | 36.79 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 127.42 | 0.00 | 127.42 | 278.52 | 13.59 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 244.69 | 49.45 | 195.24 | 597.71 | 71.19 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 486.57 | 163.99 | 322.59 | 987.22 | 122.27 | 0.00 | 0.00 | 0.00 |
February | 551.77 | 202.31 | 349.47 | 1145.53 | 94.82 | 0.00 | 0.00 | 0.00 |
March | 601.54 | 235.56 | 365.98 | 1280.94 | 63.46 | 0.00 | 0.00 | 0.00 |
April | 607.95 | 232.26 | 375.69 | 1327.62 | 28.95 | 0.00 | 0.00 | 0.00 |
May | 522.58 | 158.18 | 364.40 | 1186.70 | 35.70 | 0.00 | 0.00 | 0.00 |
June | 556.59 | 183.31 | 373.28 | 1247.38 | 39.62 | 0.00 | 0.00 | 0.00 |
July | 475.41 | 106.50 | 368.91 | 1003.33 | 71.25 | 0.00 | 0.00 | 0.00 |
August | 523.20 | 153.80 | 369.40 | 1086.49 | 57.73 | 0.00 | 0.00 | 0.00 |
September | 491.35 | 133.89 | 357.45 | 1048.41 | 57.76 | 0.00 | 0.00 | 0.00 |
October | 460.50 | 117.81 | 342.69 | 937.66 | 73.77 | 0.00 | 0.00 | 0.00 |
November | 445.67 | 123.16 | 322.51 | 912.17 | 89.24 | 0.00 | 0.00 | 0.00 |
December | 456.07 | 146.36 | 309.72 | 921.19 | 137.74 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 514.52 | 162.72 | 351.80 | 1089.46 | 72.72 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 445.67 | 106.50 | 309.72 | 912.17 | 28.95 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 607.95 | 235.56 | 375.69 | 1327.62 | 137.74 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 19.24 | 6.48 | 12.75 | 39.03 | 4.83 | 0.00 | 0.00 | 0.00 |
February | 21.82 | 8.00 | 13.82 | 45.29 | 3.75 | 0.00 | 0.00 | 0.00 |
March | 23.78 | 9.31 | 14.47 | 50.65 | 2.51 | 0.00 | 0.00 | 0.00 |
April | 24.04 | 9.18 | 14.85 | 52.49 | 1.14 | 0.00 | 0.00 | 0.00 |
May | 20.66 | 6.25 | 14.41 | 46.92 | 1.41 | 0.00 | 0.00 | 0.00 |
June | 22.01 | 7.25 | 14.76 | 49.32 | 1.57 | 0.00 | 0.00 | 0.00 |
July | 18.80 | 4.21 | 14.59 | 39.67 | 2.82 | 0.00 | 0.00 | 0.00 |
August | 20.69 | 6.08 | 14.61 | 42.96 | 2.28 | 0.00 | 0.00 | 0.00 |
September | 19.43 | 5.29 | 14.13 | 41.45 | 2.28 | 0.00 | 0.00 | 0.00 |
October | 18.21 | 4.66 | 13.55 | 37.07 | 2.92 | 0.00 | 0.00 | 0.00 |
November | 17.62 | 4.87 | 12.75 | 36.07 | 3.53 | 0.00 | 0.00 | 0.00 |
December | 18.03 | 5.79 | 12.25 | 36.42 | 5.45 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 20.34 | 6.43 | 13.91 | 43.08 | 2.88 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 17.62 | 4.21 | 12.25 | 36.07 | 1.14 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 24.04 | 9.31 | 14.85 | 52.49 | 5.45 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 347.27 | 144.88 | 202.38 | 705.35 | 71.23 | 0.00 | 0.00 | 0.00 |
February | 294.88 | 96.14 | 198.74 | 643.27 | 54.43 | 0.00 | 0.00 | 0.00 |
March | 201.24 | 27.03 | 174.21 | 486.14 | 33.71 | 0.00 | 0.00 | 0.00 |
April | 150.03 | 0.07 | 149.97 | 381.07 | 13.11 | 0.00 | 0.00 | 0.00 |
May | 150.14 | 0.00 | 150.14 | 390.21 | 16.94 | 0.00 | 0.00 | 0.00 |
June | 149.60 | 0.00 | 149.60 | 386.19 | 18.27 | 0.00 | 0.00 | 0.00 |
July | 154.11 | 0.00 | 154.11 | 347.75 | 35.16 | 0.00 | 0.00 | 0.00 |
August | 150.02 | 0.23 | 149.79 | 339.17 | 27.08 | 0.00 | 0.00 | 0.00 |
September | 166.09 | 5.42 | 160.66 | 384.19 | 28.64 | 0.00 | 0.00 | 0.00 |
October | 217.29 | 34.65 | 182.64 | 463.04 | 40.00 | 0.00 | 0.00 | 0.00 |
November | 282.55 | 86.20 | 196.35 | 583.97 | 51.05 | 0.00 | 0.00 | 0.00 |
December | 347.09 | 147.67 | 199.42 | 695.67 | 79.78 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 217.22 | 45.02 | 172.21 | 483.07 | 39.11 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 149.60 | 0.00 | 149.60 | 339.17 | 13.11 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 347.27 | 147.67 | 202.38 | 705.35 | 79.78 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 347.27 | 144.88 | 202.38 | 705.35 | 71.23 | 0.00 | 0.00 | 0.00 |
February | 294.88 | 96.14 | 198.74 | 643.27 | 54.43 | 0.00 | 0.00 | 0.00 |
March | 201.24 | 27.03 | 174.21 | 486.14 | 33.71 | 0.00 | 0.00 | 0.00 |
April | 150.03 | 0.07 | 149.97 | 381.07 | 13.11 | 0.00 | 0.00 | 0.00 |
May | 150.14 | 0.00 | 150.14 | 390.21 | 16.94 | 0.00 | 0.00 | 0.00 |
June | 149.60 | 0.00 | 149.60 | 386.19 | 18.27 | 0.00 | 0.00 | 0.00 |
July | 154.11 | 0.00 | 154.11 | 347.75 | 35.16 | 0.00 | 0.00 | 0.00 |
August | 150.02 | 0.23 | 149.79 | 339.17 | 27.08 | 0.00 | 0.00 | 0.00 |
September | 166.09 | 5.42 | 160.66 | 384.19 | 28.64 | 0.00 | 0.00 | 0.00 |
October | 217.29 | 34.65 | 182.64 | 463.04 | 40.00 | 0.00 | 0.00 | 0.00 |
November | 282.55 | 86.20 | 196.35 | 583.97 | 51.05 | 0.00 | 0.00 | 0.00 |
December | 347.09 | 147.67 | 199.42 | 695.67 | 79.78 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 217.22 | 45.02 | 172.21 | 483.07 | 39.11 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 149.60 | 0.00 | 149.60 | 339.17 | 13.11 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 347.27 | 147.67 | 202.38 | 705.35 | 79.78 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 347.24 | 144.87 | 202.37 | 705.30 | 71.23 | 0.00 | 0.00 | 0.00 |
February | 294.86 | 96.14 | 198.73 | 643.23 | 54.43 | 0.00 | 0.00 | 0.00 |
March | 201.23 | 27.02 | 174.20 | 486.11 | 33.71 | 0.00 | 0.00 | 0.00 |
April | 150.02 | 0.07 | 149.96 | 381.05 | 13.11 | 0.00 | 0.00 | 0.00 |
May | 150.13 | 0.00 | 150.13 | 390.19 | 16.94 | 0.00 | 0.00 | 0.00 |
June | 149.59 | 0.00 | 149.59 | 386.17 | 18.27 | 0.00 | 0.00 | 0.00 |
July | 154.10 | 0.00 | 154.10 | 347.73 | 35.16 | 0.00 | 0.00 | 0.00 |
August | 150.01 | 0.23 | 149.78 | 339.15 | 27.08 | 0.00 | 0.00 | 0.00 |
September | 166.08 | 5.42 | 160.65 | 384.16 | 28.64 | 0.00 | 0.00 | 0.00 |
October | 217.28 | 34.64 | 182.63 | 463.01 | 40.00 | 0.00 | 0.00 | 0.00 |
November | 282.53 | 86.20 | 196.33 | 583.94 | 51.05 | 0.00 | 0.00 | 0.00 |
December | 347.07 | 147.66 | 199.40 | 695.63 | 79.77 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 217.21 | 45.01 | 172.20 | 483.04 | 39.11 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 149.59 | 0.00 | 149.59 | 339.15 | 13.11 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 347.24 | 147.66 | 202.37 | 705.30 | 79.77 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 493.00 | 173.36 | 319.65 | 1011.99 | 135.55 | 0.00 | 0.00 | 0.00 |
February | 541.46 | 191.61 | 349.85 | 1137.11 | 106.42 | 0.00 | 0.00 | 0.00 |
March | 606.94 | 239.73 | 367.21 | 1297.96 | 76.32 | 0.00 | 0.00 | 0.00 |
April | 609.94 | 233.61 | 376.32 | 1322.44 | 35.44 | 0.00 | 0.00 | 0.00 |
May | 518.99 | 153.75 | 365.24 | 1171.62 | 37.07 | 0.00 | 0.00 | 0.00 |
June | 562.39 | 193.84 | 368.55 | 1249.85 | 41.64 | 0.00 | 0.00 | 0.00 |
July | 479.47 | 113.07 | 366.40 | 1010.15 | 74.61 | 0.00 | 0.00 | 0.00 |
August | 521.28 | 154.37 | 366.91 | 1076.50 | 60.14 | 0.00 | 0.00 | 0.00 |
September | 488.25 | 135.42 | 352.83 | 1037.41 | 60.76 | 0.00 | 0.00 | 0.00 |
October | 458.57 | 118.21 | 340.36 | 932.21 | 78.05 | 0.00 | 0.00 | 0.00 |
November | 447.19 | 121.96 | 325.23 | 917.33 | 94.01 | 0.00 | 0.00 | 0.00 |
December | 457.67 | 149.71 | 307.96 | 938.09 | 149.37 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 515.09 | 164.60 | 350.49 | 1091.08 | 79.12 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 447.19 | 113.07 | 307.96 | 917.33 | 35.44 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 609.94 | 239.73 | 376.32 | 1322.44 | 149.37 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 19.49 | 6.85 | 12.64 | 40.01 | 5.36 | 0.00 | 0.00 | 0.00 |
February | 21.41 | 7.58 | 13.83 | 44.96 | 4.21 | 0.00 | 0.00 | 0.00 |
March | 24.00 | 9.48 | 14.52 | 51.32 | 3.02 | 0.00 | 0.00 | 0.00 |
April | 24.12 | 9.24 | 14.88 | 52.29 | 1.40 | 0.00 | 0.00 | 0.00 |
May | 20.52 | 6.08 | 14.44 | 46.32 | 1.47 | 0.00 | 0.00 | 0.00 |
June | 22.24 | 7.66 | 14.57 | 49.42 | 1.65 | 0.00 | 0.00 | 0.00 |
July | 18.96 | 4.47 | 14.49 | 39.94 | 2.95 | 0.00 | 0.00 | 0.00 |
August | 20.61 | 6.10 | 14.51 | 42.56 | 2.38 | 0.00 | 0.00 | 0.00 |
September | 19.31 | 5.35 | 13.95 | 41.02 | 2.40 | 0.00 | 0.00 | 0.00 |
October | 18.13 | 4.67 | 13.46 | 36.86 | 3.09 | 0.00 | 0.00 | 0.00 |
November | 17.68 | 4.82 | 12.86 | 36.27 | 3.72 | 0.00 | 0.00 | 0.00 |
December | 18.10 | 5.92 | 12.18 | 37.09 | 5.91 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 20.37 | 6.51 | 13.86 | 43.14 | 3.13 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 17.68 | 4.47 | 12.18 | 36.27 | 1.40 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 24.12 | 9.48 | 14.88 | 52.29 | 5.91 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 393.48 | 0.00 | 393.48 | 871.25 | 189.65 | 0.00 | 0.00 | 0.00 |
February | 419.73 | 0.00 | 419.73 | 975.93 | 143.72 | 0.00 | 0.00 | 0.00 |
March | 430.77 | 0.00 | 430.77 | 1062.09 | 93.75 | 0.00 | 0.00 | 0.00 |
April | 468.79 | 6.64 | 462.15 | 1193.22 | 38.97 | 0.00 | 0.00 | 0.00 |
May | 600.94 | 64.02 | 536.92 | 1517.76 | 49.16 | 0.00 | 0.00 | 0.00 |
June | 734.07 | 148.35 | 585.72 | 1801.28 | 55.46 | 0.00 | 0.00 | 0.00 |
July | 631.23 | 66.16 | 565.06 | 1417.33 | 101.22 | 0.00 | 0.00 | 0.00 |
August | 519.71 | 22.16 | 497.55 | 1185.46 | 76.05 | 0.00 | 0.00 | 0.00 |
September | 442.47 | 0.21 | 442.26 | 1043.84 | 75.28 | 0.00 | 0.00 | 0.00 |
October | 426.34 | 0.00 | 426.34 | 930.93 | 101.27 | 0.00 | 0.00 | 0.00 |
November | 403.41 | 0.00 | 403.41 | 888.72 | 126.59 | 0.00 | 0.00 | 0.00 |
December | 382.26 | 0.00 | 382.26 | 839.01 | 208.02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 488.06 | 25.70 | 462.36 | 1144.32 | 104.95 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 382.26 | 0.00 | 382.26 | 839.01 | 38.97 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 734.07 | 148.35 | 585.72 | 1801.28 | 208.02 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_2_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 505.82 | 170.47 | 335.34 | 1028.98 | 120.15 | 0.00 | 0.00 | 0.00 |
February | 573.59 | 210.31 | 363.29 | 1194.07 | 89.95 | 0.00 | 0.00 | 0.00 |
March | 625.33 | 244.87 | 380.45 | 1334.27 | 57.77 | 0.00 | 0.00 | 0.00 |
April | 631.99 | 241.44 | 390.54 | 1386.05 | 24.55 | 0.00 | 0.00 | 0.00 |
May | 543.25 | 164.44 | 378.81 | 1240.86 | 31.78 | 0.00 | 0.00 | 0.00 |
June | 578.61 | 190.56 | 388.04 | 1303.88 | 34.91 | 0.00 | 0.00 | 0.00 |
July | 494.21 | 110.71 | 383.49 | 1048.32 | 65.12 | 0.00 | 0.00 | 0.00 |
August | 543.89 | 159.88 | 384.01 | 1135.88 | 50.04 | 0.00 | 0.00 | 0.00 |
September | 510.78 | 139.19 | 371.59 | 1096.27 | 50.69 | 0.00 | 0.00 | 0.00 |
October | 478.71 | 122.47 | 356.24 | 978.18 | 67.83 | 0.00 | 0.00 | 0.00 |
November | 463.30 | 128.03 | 335.27 | 951.29 | 84.07 | 0.00 | 0.00 | 0.00 |
December | 474.11 | 152.15 | 321.96 | 960.24 | 133.76 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 534.86 | 169.15 | 365.71 | 1137.23 | 67.58 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 463.30 | 110.71 | 321.96 | 951.29 | 24.55 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 631.99 | 244.87 | 390.54 | 1386.05 | 133.76 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 1041.77 | 434.64 | 607.13 | 2134.37 | 193.28 | 0.00 | 0.00 | 0.00 |
February | 884.62 | 288.42 | 596.20 | 1953.28 | 142.98 | 0.00 | 0.00 | 0.00 |
March | 603.70 | 81.08 | 522.62 | 1478.75 | 89.56 | 0.00 | 0.00 | 0.00 |
April | 450.09 | 0.20 | 449.89 | 1161.64 | 34.94 | 0.00 | 0.00 | 0.00 |
May | 450.40 | 0.00 | 450.40 | 1190.81 | 45.28 | 0.00 | 0.00 | 0.00 |
June | 448.78 | 0.00 | 448.78 | 1182.95 | 48.99 | 0.00 | 0.00 | 0.00 |
July | 462.31 | 0.00 | 462.31 | 1055.54 | 95.65 | 0.00 | 0.00 | 0.00 |
August | 450.06 | 0.70 | 449.36 | 1034.57 | 70.38 | 0.00 | 0.00 | 0.00 |
September | 498.25 | 16.27 | 481.97 | 1168.14 | 75.50 | 0.00 | 0.00 | 0.00 |
October | 651.85 | 103.93 | 547.92 | 1400.53 | 106.97 | 0.00 | 0.00 | 0.00 |
November | 847.62 | 258.60 | 589.02 | 1768.77 | 135.08 | 0.00 | 0.00 | 0.00 |
December | 1041.23 | 443.00 | 598.23 | 2101.46 | 216.07 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 651.65 | 135.05 | 516.60 | 1466.89 | 104.58 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 448.78 | 0.00 | 448.78 | 1034.57 | 34.94 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1041.77 | 443.00 | 607.13 | 2134.37 | 216.07 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_4_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 512.50 | 180.21 | 332.29 | 1054.73 | 134.02 | 0.00 | 0.00 | 0.00 |
February | 562.87 | 199.19 | 363.69 | 1185.12 | 101.62 | 0.00 | 0.00 | 0.00 |
March | 630.94 | 249.21 | 381.73 | 1351.97 | 71.19 | 0.00 | 0.00 | 0.00 |
April | 634.06 | 242.85 | 391.21 | 1379.81 | 30.51 | 0.00 | 0.00 | 0.00 |
May | 539.52 | 159.83 | 379.68 | 1224.89 | 32.50 | 0.00 | 0.00 | 0.00 |
June | 584.63 | 201.51 | 383.12 | 1306.68 | 36.44 | 0.00 | 0.00 | 0.00 |
July | 498.43 | 117.54 | 380.89 | 1055.11 | 67.95 | 0.00 | 0.00 | 0.00 |
August | 541.89 | 160.48 | 381.41 | 1125.44 | 51.91 | 0.00 | 0.00 | 0.00 |
September | 507.56 | 140.77 | 366.79 | 1084.67 | 53.78 | 0.00 | 0.00 | 0.00 |
October | 476.70 | 122.88 | 353.82 | 973.12 | 71.89 | 0.00 | 0.00 | 0.00 |
November | 464.88 | 126.79 | 338.09 | 957.35 | 89.10 | 0.00 | 0.00 | 0.00 |
December | 475.77 | 155.63 | 320.14 | 978.55 | 145.62 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 535.46 | 171.11 | 364.35 | 1138.95 | 73.88 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 464.88 | 117.54 | 320.14 | 957.35 | 30.51 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 634.06 | 249.21 | 391.21 | 1379.81 | 145.62 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.105389E+10 | 0.00 | 0.105389E+10 | 0.231292E+10 | 0.488214E+09 |
February | 0.101541E+10 | 0.00 | 0.101541E+10 | 0.233615E+10 | 0.333259E+09 |
March | 0.115378E+10 | 0.00 | 0.115378E+10 | 0.281081E+10 | 0.245374E+09 |
April | 0.121512E+10 | 17220475.84 | 0.119790E+10 | 0.304854E+10 | 0.103128E+09 |
May | 0.160955E+10 | 0.171466E+09 | 0.143809E+10 | 0.402126E+10 | 0.131718E+09 |
June | 0.190270E+10 | 0.384521E+09 | 0.151818E+10 | 0.462526E+10 | 0.146162E+09 |
July | 0.169068E+10 | 0.177214E+09 | 0.151347E+10 | 0.375919E+10 | 0.269426E+09 |
August | 0.139198E+10 | 59355272.39 | 0.133263E+10 | 0.314733E+10 | 0.198252E+09 |
September | 0.114689E+10 | 549193.87 | 0.114634E+10 | 0.267229E+10 | 0.193453E+09 |
October | 0.114191E+10 | 0.00 | 0.114191E+10 | 0.246767E+10 | 0.264283E+09 |
November | 0.104564E+10 | 0.00 | 0.104564E+10 | 0.228104E+10 | 0.313299E+09 |
December | 0.102384E+10 | 0.00 | 0.102384E+10 | 0.223069E+10 | 0.530062E+09 |
Annual Sum or Average | 0.153914E+11 | 0.810326E+09 | 0.145811E+11 | 0.357131E+11 | 0.321663E+10 |
Minimum of Months | 0.101541E+10 | 0.00 | 0.101541E+10 | 0.223069E+10 | 0.103128E+09 |
Maximum of Months | 0.190270E+10 | 0.384521E+09 | 0.151818E+10 | 0.462526E+10 | 0.530062E+09 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.135478E+10 | 0.456598E+09 | 0.898181E+09 | 0.273935E+10 | 0.310564E+09 |
February | 0.138764E+10 | 0.508775E+09 | 0.878863E+09 | 0.286929E+10 | 0.208661E+09 |
March | 0.167487E+10 | 0.655870E+09 | 0.101900E+10 | 0.354660E+10 | 0.150202E+09 |
April | 0.163811E+10 | 0.625825E+09 | 0.101229E+10 | 0.356087E+10 | 64563054.61 |
May | 0.145504E+10 | 0.440436E+09 | 0.101460E+10 | 0.329374E+10 | 84949666.38 |
June | 0.149975E+10 | 0.493936E+09 | 0.100581E+10 | 0.335002E+10 | 92006171.37 |
July | 0.132369E+10 | 0.296539E+09 | 0.102715E+10 | 0.278359E+10 | 0.173296E+09 |
August | 0.145675E+10 | 0.428221E+09 | 0.102853E+10 | 0.302235E+10 | 0.130424E+09 |
September | 0.132393E+10 | 0.360776E+09 | 0.963157E+09 | 0.281799E+10 | 0.130404E+09 |
October | 0.128218E+10 | 0.328027E+09 | 0.954154E+09 | 0.260074E+10 | 0.177444E+09 |
November | 0.120086E+10 | 0.331853E+09 | 0.869011E+09 | 0.244832E+10 | 0.209078E+09 |
December | 0.126985E+10 | 0.407507E+09 | 0.862347E+09 | 0.255824E+10 | 0.342907E+09 |
Annual Sum or Average | 0.168675E+11 | 0.533436E+10 | 0.115331E+11 | 0.355911E+11 | 0.207450E+10 |
Minimum of Months | 0.120086E+10 | 0.296539E+09 | 0.862347E+09 | 0.244832E+10 | 64563054.61 |
Maximum of Months | 0.167487E+10 | 0.655870E+09 | 0.102853E+10 | 0.356087E+10 | 0.342907E+09 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.279027E+10 | 0.116413E+10 | 0.162614E+10 | 0.569726E+10 | 0.500710E+09 |
February | 0.214007E+10 | 0.697740E+09 | 0.144233E+10 | 0.470075E+10 | 0.332189E+09 |
March | 0.161696E+10 | 0.217157E+09 | 0.139980E+10 | 0.392450E+10 | 0.232827E+09 |
April | 0.116663E+10 | 523706.84 | 0.116611E+10 | 0.296743E+10 | 91754055.95 |
May | 0.120634E+10 | 0.00 | 0.120634E+10 | 0.314679E+10 | 0.120335E+09 |
June | 0.116323E+10 | 0.00 | 0.116323E+10 | 0.302458E+10 | 0.128664E+09 |
July | 0.123824E+10 | 0.00 | 0.123824E+10 | 0.279245E+10 | 0.253675E+09 |
August | 0.120544E+10 | 1863017.82 | 0.120357E+10 | 0.274382E+10 | 0.181770E+09 |
September | 0.129146E+10 | 42179677.96 | 0.124928E+10 | 0.299349E+10 | 0.193885E+09 |
October | 0.174592E+10 | 0.278372E+09 | 0.146755E+10 | 0.372263E+10 | 0.279971E+09 |
November | 0.219703E+10 | 0.670283E+09 | 0.152675E+10 | 0.456060E+10 | 0.337103E+09 |
December | 0.278884E+10 | 0.118653E+10 | 0.160230E+10 | 0.561299E+10 | 0.555893E+09 |
Annual Sum or Average | 0.205504E+11 | 0.425878E+10 | 0.162916E+11 | 0.458873E+11 | 0.320878E+10 |
Minimum of Months | 0.116323E+10 | 0.00 | 0.116323E+10 | 0.274382E+10 | 91754055.95 |
Maximum of Months | 0.279027E+10 | 0.118653E+10 | 0.162614E+10 | 0.569726E+10 | 0.555893E+09 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.137268E+10 | 0.482679E+09 | 0.890005E+09 | 0.281425E+10 | 0.343759E+09 |
February | 0.136171E+10 | 0.481875E+09 | 0.879831E+09 | 0.285225E+10 | 0.234408E+09 |
March | 0.168991E+10 | 0.667480E+09 | 0.102243E+10 | 0.359998E+10 | 0.185381E+09 |
April | 0.164348E+10 | 0.629477E+09 | 0.101401E+10 | 0.355090E+10 | 79565179.32 |
May | 0.144504E+10 | 0.428097E+09 | 0.101694E+10 | 0.325613E+10 | 85312582.07 |
June | 0.151537E+10 | 0.522310E+09 | 0.993057E+09 | 0.336093E+10 | 93965896.00 |
July | 0.133499E+10 | 0.314821E+09 | 0.102017E+10 | 0.280588E+10 | 0.178012E+09 |
August | 0.145140E+10 | 0.429822E+09 | 0.102158E+10 | 0.299816E+10 | 0.132907E+09 |
September | 0.131560E+10 | 0.364888E+09 | 0.950711E+09 | 0.279230E+10 | 0.136254E+09 |
October | 0.127679E+10 | 0.329129E+09 | 0.947664E+09 | 0.259272E+10 | 0.185654E+09 |
November | 0.120497E+10 | 0.328630E+09 | 0.876335E+09 | 0.246960E+10 | 0.219156E+09 |
December | 0.127429E+10 | 0.416844E+09 | 0.857451E+09 | 0.261307E+10 | 0.369551E+09 |
Annual Sum or Average | 0.168862E+11 | 0.539605E+10 | 0.114902E+11 | 0.357062E+11 | 0.224392E+10 |
Minimum of Months | 0.120497E+10 | 0.314821E+09 | 0.857451E+09 | 0.246960E+10 | 79565179.32 |
Maximum of Months | 0.168991E+10 | 0.667480E+09 | 0.102243E+10 | 0.359998E+10 | 0.369551E+09 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.351279E+09 | 0.00 | 0.351279E+09 | 0.775615E+09 | 0.170605E+09 |
February | 0.338455E+09 | 0.00 | 0.338455E+09 | 0.784881E+09 | 0.118442E+09 |
March | 0.384575E+09 | 0.00 | 0.384575E+09 | 0.945520E+09 | 85116132.54 |
April | 0.405020E+09 | 5739887.04 | 0.399280E+09 | 0.102732E+10 | 35234348.65 |
May | 0.536493E+09 | 57152608.13 | 0.479340E+09 | 0.134984E+10 | 48588021.53 |
June | 0.634205E+09 | 0.128168E+09 | 0.506037E+09 | 0.154917E+10 | 54378585.56 |
July | 0.563535E+09 | 59068497.01 | 0.504466E+09 | 0.126056E+10 | 99617026.64 |
August | 0.463973E+09 | 19784154.72 | 0.444189E+09 | 0.105091E+10 | 76372412.70 |
September | 0.382279E+09 | 183055.96 | 0.382096E+09 | 0.895330E+09 | 71329100.44 |
October | 0.380619E+09 | 0.00 | 0.380619E+09 | 0.827957E+09 | 95549780.64 |
November | 0.348532E+09 | 0.00 | 0.348532E+09 | 0.765089E+09 | 0.114115E+09 |
December | 0.341263E+09 | 0.00 | 0.341263E+09 | 0.745947E+09 | 0.190651E+09 |
Annual Sum or Average | 0.513023E+10 | 0.270096E+09 | 0.486013E+10 | 0.119781E+11 | 0.116000E+10 |
Minimum of Months | 0.338455E+09 | 0.00 | 0.338455E+09 | 0.745947E+09 | 35234348.65 |
Maximum of Months | 0.634205E+09 | 0.128168E+09 | 0.506037E+09 | 0.154917E+10 | 0.190651E+09 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.351301E+09 | 0.00 | 0.351301E+09 | 0.775664E+09 | 0.170615E+09 |
February | 0.338477E+09 | 0.00 | 0.338477E+09 | 0.784930E+09 | 0.118449E+09 |
March | 0.384600E+09 | 0.00 | 0.384600E+09 | 0.945580E+09 | 85121511.74 |
April | 0.405045E+09 | 5740249.79 | 0.399305E+09 | 0.102739E+10 | 35236575.41 |
May | 0.536527E+09 | 57156220.08 | 0.479371E+09 | 0.134992E+10 | 48591092.22 |
June | 0.634245E+09 | 0.128176E+09 | 0.506069E+09 | 0.154927E+10 | 54382022.20 |
July | 0.563570E+09 | 59072230.04 | 0.504498E+09 | 0.126064E+10 | 99623322.27 |
August | 0.464002E+09 | 19785405.05 | 0.444217E+09 | 0.105098E+10 | 76377239.31 |
September | 0.382303E+09 | 183067.53 | 0.382120E+09 | 0.895386E+09 | 71333608.32 |
October | 0.380643E+09 | 0.00 | 0.380643E+09 | 0.828010E+09 | 95555819.23 |
November | 0.348554E+09 | 0.00 | 0.348554E+09 | 0.765137E+09 | 0.114122E+09 |
December | 0.341284E+09 | 0.00 | 0.341284E+09 | 0.745994E+09 | 0.190663E+09 |
Annual Sum or Average | 0.513055E+10 | 0.270113E+09 | 0.486044E+10 | 0.119789E+11 | 0.116007E+10 |
Minimum of Months | 0.338477E+09 | 0.00 | 0.338477E+09 | 0.745994E+09 | 35236575.41 |
Maximum of Months | 0.634245E+09 | 0.128176E+09 | 0.506069E+09 | 0.154927E+10 | 0.190663E+09 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.351301E+09 | 0.00 | 0.351301E+09 | 0.775664E+09 | 0.170615E+09 |
February | 0.338477E+09 | 0.00 | 0.338477E+09 | 0.784930E+09 | 0.118449E+09 |
March | 0.384600E+09 | 0.00 | 0.384600E+09 | 0.945580E+09 | 85121511.74 |
April | 0.405045E+09 | 5740249.79 | 0.399305E+09 | 0.102739E+10 | 35236575.41 |
May | 0.536527E+09 | 57156220.08 | 0.479371E+09 | 0.134992E+10 | 48591092.22 |
June | 0.634245E+09 | 0.128176E+09 | 0.506069E+09 | 0.154927E+10 | 54382022.20 |
July | 0.563570E+09 | 59072230.04 | 0.504498E+09 | 0.126064E+10 | 99623322.27 |
August | 0.464002E+09 | 19785405.05 | 0.444217E+09 | 0.105098E+10 | 76377239.31 |
September | 0.382303E+09 | 183067.53 | 0.382120E+09 | 0.895386E+09 | 71333608.32 |
October | 0.380643E+09 | 0.00 | 0.380643E+09 | 0.828010E+09 | 95555819.23 |
November | 0.348554E+09 | 0.00 | 0.348554E+09 | 0.765137E+09 | 0.114122E+09 |
December | 0.341284E+09 | 0.00 | 0.341284E+09 | 0.745994E+09 | 0.190663E+09 |
Annual Sum or Average | 0.513055E+10 | 0.270113E+09 | 0.486044E+10 | 0.119789E+11 | 0.116007E+10 |
Minimum of Months | 0.338477E+09 | 0.00 | 0.338477E+09 | 0.745994E+09 | 35236575.41 |
Maximum of Months | 0.634245E+09 | 0.128176E+09 | 0.506069E+09 | 0.154927E+10 | 0.190663E+09 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.130324E+10 | 0.439227E+09 | 0.864013E+09 | 0.264418E+10 | 0.327477E+09 |
February | 0.133485E+10 | 0.489419E+09 | 0.845430E+09 | 0.277126E+10 | 0.229384E+09 |
March | 0.161116E+10 | 0.630918E+09 | 0.980239E+09 | 0.343086E+10 | 0.169962E+09 |
April | 0.157579E+10 | 0.602016E+09 | 0.973778E+09 | 0.344119E+10 | 75047356.72 |
May | 0.139969E+10 | 0.423680E+09 | 0.976006E+09 | 0.317846E+10 | 95629896.77 |
June | 0.144269E+10 | 0.475144E+09 | 0.967550E+09 | 0.323321E+10 | 0.102690E+09 |
July | 0.127334E+10 | 0.285257E+09 | 0.988078E+09 | 0.268731E+10 | 0.190845E+09 |
August | 0.140133E+10 | 0.411929E+09 | 0.989400E+09 | 0.291006E+10 | 0.154632E+09 |
September | 0.127357E+10 | 0.347051E+09 | 0.926517E+09 | 0.271749E+10 | 0.149702E+09 |
October | 0.123340E+10 | 0.315547E+09 | 0.917857E+09 | 0.251143E+10 | 0.197586E+09 |
November | 0.115518E+10 | 0.319228E+09 | 0.835953E+09 | 0.236434E+10 | 0.231318E+09 |
December | 0.122155E+10 | 0.392003E+09 | 0.829543E+09 | 0.246731E+10 | 0.368927E+09 |
Annual Sum or Average | 0.162258E+11 | 0.513142E+10 | 0.110944E+11 | 0.343571E+11 | 0.229320E+10 |
Minimum of Months | 0.115518E+10 | 0.285257E+09 | 0.829543E+09 | 0.236434E+10 | 75047356.72 |
Maximum of Months | 0.161116E+10 | 0.630918E+09 | 0.989400E+09 | 0.344119E+10 | 0.368927E+09 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 51528941.43 | 17366636.19 | 34162305.24 | 0.104548E+09 | 12948137.56 |
February | 52778713.52 | 19351173.48 | 33427540.03 | 0.109573E+09 | 9069644.77 |
March | 63703692.53 | 24945915.92 | 38757776.61 | 0.135653E+09 | 6720139.78 |
April | 62305460.74 | 23803168.24 | 38502292.50 | 0.136062E+09 | 2967304.92 |
May | 55342312.85 | 16751921.92 | 38590390.93 | 0.125674E+09 | 3781120.02 |
June | 57042827.41 | 18786778.30 | 38256049.11 | 0.127838E+09 | 4060250.91 |
July | 50346520.06 | 11278794.67 | 39067725.39 | 0.106254E+09 | 7545856.32 |
August | 55407279.40 | 16287300.31 | 39119979.10 | 0.115061E+09 | 6114010.36 |
September | 50355735.17 | 13722070.50 | 36633664.67 | 0.107447E+09 | 5919096.02 |
October | 48767674.78 | 12476435.65 | 36291239.13 | 99299540.39 | 7812373.00 |
November | 45674809.35 | 12621980.35 | 33052829.00 | 93484005.03 | 9146113.56 |
December | 48298830.37 | 15499465.22 | 32799365.15 | 97555324.93 | 14587038.86 |
Annual Sum or Average | 0.641553E+09 | 0.202892E+09 | 0.438661E+09 | 0.135845E+10 | 90671086.08 |
Minimum of Months | 45674809.35 | 11278794.67 | 32799365.15 | 93484005.03 | 2967304.92 |
Maximum of Months | 63703692.53 | 24945915.92 | 39119979.10 | 0.136062E+09 | 14587038.86 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.930118E+09 | 0.388056E+09 | 0.542062E+09 | 0.188920E+10 | 0.190784E+09 |
February | 0.713377E+09 | 0.232588E+09 | 0.480789E+09 | 0.155620E+10 | 0.131685E+09 |
March | 0.539000E+09 | 72388130.14 | 0.466612E+09 | 0.130208E+10 | 90294430.72 |
April | 0.388888E+09 | 174574.66 | 0.388713E+09 | 0.987732E+09 | 33976790.76 |
May | 0.402125E+09 | 0.00 | 0.402125E+09 | 0.104514E+10 | 45366666.64 |
June | 0.387752E+09 | 0.00 | 0.387752E+09 | 0.100100E+10 | 47347890.78 |
July | 0.412758E+09 | 0.00 | 0.412758E+09 | 0.931420E+09 | 94165734.80 |
August | 0.401823E+09 | 621026.25 | 0.401202E+09 | 0.908428E+09 | 72524072.19 |
September | 0.430497E+09 | 14060352.53 | 0.416437E+09 | 0.995812E+09 | 74243638.85 |
October | 0.581990E+09 | 92793677.92 | 0.489196E+09 | 0.124021E+10 | 0.107132E+09 |
November | 0.732366E+09 | 0.223435E+09 | 0.508931E+09 | 0.151366E+10 | 0.132332E+09 |
December | 0.929642E+09 | 0.395524E+09 | 0.534117E+09 | 0.186329E+10 | 0.213673E+09 |
Annual Sum or Average | 0.685034E+10 | 0.141964E+10 | 0.543070E+10 | 0.152342E+11 | 0.123353E+10 |
Minimum of Months | 0.387752E+09 | 0.00 | 0.387752E+09 | 0.908428E+09 | 33976790.76 |
Maximum of Months | 0.930118E+09 | 0.395524E+09 | 0.542062E+09 | 0.188920E+10 | 0.213673E+09 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.930118E+09 | 0.388056E+09 | 0.542062E+09 | 0.188920E+10 | 0.190784E+09 |
February | 0.713377E+09 | 0.232588E+09 | 0.480789E+09 | 0.155620E+10 | 0.131685E+09 |
March | 0.539000E+09 | 72388130.14 | 0.466612E+09 | 0.130208E+10 | 90294430.72 |
April | 0.388888E+09 | 174574.66 | 0.388713E+09 | 0.987732E+09 | 33976790.76 |
May | 0.402125E+09 | 0.00 | 0.402125E+09 | 0.104514E+10 | 45366666.64 |
June | 0.387752E+09 | 0.00 | 0.387752E+09 | 0.100100E+10 | 47347890.78 |
July | 0.412758E+09 | 0.00 | 0.412758E+09 | 0.931420E+09 | 94165734.80 |
August | 0.401823E+09 | 621026.25 | 0.401202E+09 | 0.908428E+09 | 72524072.19 |
September | 0.430497E+09 | 14060352.53 | 0.416437E+09 | 0.995812E+09 | 74243638.85 |
October | 0.581990E+09 | 92793677.92 | 0.489196E+09 | 0.124021E+10 | 0.107132E+09 |
November | 0.732366E+09 | 0.223435E+09 | 0.508931E+09 | 0.151366E+10 | 0.132332E+09 |
December | 0.929642E+09 | 0.395524E+09 | 0.534117E+09 | 0.186329E+10 | 0.213673E+09 |
Annual Sum or Average | 0.685034E+10 | 0.141964E+10 | 0.543070E+10 | 0.152342E+11 | 0.123353E+10 |
Minimum of Months | 0.387752E+09 | 0.00 | 0.387752E+09 | 0.908428E+09 | 33976790.76 |
Maximum of Months | 0.930118E+09 | 0.395524E+09 | 0.542062E+09 | 0.188920E+10 | 0.213673E+09 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.930059E+09 | 0.388031E+09 | 0.542028E+09 | 0.188908E+10 | 0.190772E+09 |
February | 0.713332E+09 | 0.232573E+09 | 0.480759E+09 | 0.155610E+10 | 0.131677E+09 |
March | 0.538966E+09 | 72383555.62 | 0.466583E+09 | 0.130200E+10 | 90288724.63 |
April | 0.388863E+09 | 174563.63 | 0.388689E+09 | 0.987669E+09 | 33974643.62 |
May | 0.402100E+09 | 0.00 | 0.402100E+09 | 0.104508E+10 | 45363799.72 |
June | 0.387728E+09 | 0.00 | 0.387728E+09 | 0.100094E+10 | 47344898.66 |
July | 0.412732E+09 | 0.00 | 0.412732E+09 | 0.931361E+09 | 94159784.06 |
August | 0.401798E+09 | 620987.01 | 0.401177E+09 | 0.908371E+09 | 72519489.08 |
September | 0.430470E+09 | 14059464.00 | 0.416410E+09 | 0.995749E+09 | 74238947.07 |
October | 0.581953E+09 | 92787813.88 | 0.489165E+09 | 0.124013E+10 | 0.107126E+09 |
November | 0.732320E+09 | 0.223421E+09 | 0.508899E+09 | 0.151357E+10 | 0.132324E+09 |
December | 0.929583E+09 | 0.395499E+09 | 0.534083E+09 | 0.186317E+10 | 0.213659E+09 |
Annual Sum or Average | 0.684990E+10 | 0.141955E+10 | 0.543035E+10 | 0.152332E+11 | 0.123345E+10 |
Minimum of Months | 0.387728E+09 | 0.00 | 0.387728E+09 | 0.908371E+09 | 33974643.62 |
Maximum of Months | 0.930059E+09 | 0.395499E+09 | 0.542028E+09 | 0.188908E+10 | 0.213659E+09 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.132046E+10 | 0.464316E+09 | 0.856149E+09 | 0.271051E+10 | 0.363055E+09 |
February | 0.130990E+10 | 0.463542E+09 | 0.846361E+09 | 0.275089E+10 | 0.257443E+09 |
March | 0.162562E+10 | 0.642086E+09 | 0.983535E+09 | 0.347645E+10 | 0.204427E+09 |
April | 0.158096E+10 | 0.605529E+09 | 0.975433E+09 | 0.342777E+10 | 91858909.68 |
May | 0.139007E+10 | 0.411810E+09 | 0.978255E+09 | 0.313807E+10 | 99299478.87 |
June | 0.145772E+10 | 0.502439E+09 | 0.955280E+09 | 0.323961E+10 | 0.107921E+09 |
July | 0.128421E+10 | 0.302844E+09 | 0.981362E+09 | 0.270560E+10 | 0.199842E+09 |
August | 0.139619E+10 | 0.413470E+09 | 0.982719E+09 | 0.288329E+10 | 0.161082E+09 |
September | 0.126555E+10 | 0.351006E+09 | 0.914545E+09 | 0.268896E+10 | 0.157488E+09 |
October | 0.122822E+10 | 0.316607E+09 | 0.911614E+09 | 0.249683E+10 | 0.209058E+09 |
November | 0.115913E+10 | 0.316127E+09 | 0.842998E+09 | 0.237772E+10 | 0.243662E+09 |
December | 0.122582E+10 | 0.400985E+09 | 0.824832E+09 | 0.251258E+10 | 0.400065E+09 |
Annual Sum or Average | 0.162438E+11 | 0.519076E+10 | 0.110531E+11 | 0.344083E+11 | 0.249520E+10 |
Minimum of Months | 0.115913E+10 | 0.302844E+09 | 0.824832E+09 | 0.237772E+10 | 91858909.68 |
Maximum of Months | 0.162562E+10 | 0.642086E+09 | 0.983535E+09 | 0.347645E+10 | 0.400065E+09 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 52209827.45 | 18358562.19 | 33851265.26 | 0.107171E+09 | 14354833.71 |
February | 51792250.25 | 18327966.89 | 33464283.36 | 0.108767E+09 | 10179042.91 |
March | 64275433.04 | 25387416.14 | 38888016.90 | 0.137455E+09 | 8082855.50 |
April | 62509637.36 | 23941978.01 | 38567659.35 | 0.135530E+09 | 3632003.09 |
May | 54961774.11 | 16282549.29 | 38679224.83 | 0.124076E+09 | 3926201.74 |
June | 57636731.60 | 19865912.62 | 37770818.99 | 0.128091E+09 | 4267093.45 |
July | 50776209.48 | 11974130.69 | 38802078.78 | 0.106977E+09 | 7901562.00 |
August | 55203894.46 | 16348179.06 | 38855715.39 | 0.114003E+09 | 6369008.21 |
September | 50038613.14 | 13878429.86 | 36160183.28 | 0.106319E+09 | 6226900.31 |
October | 48562613.17 | 12518320.05 | 36044293.13 | 98722194.20 | 8265935.76 |
November | 45830662.07 | 12499345.52 | 33331316.55 | 94012570.89 | 9634171.05 |
December | 48467592.82 | 15854538.25 | 32613054.57 | 99344883.22 | 15818192.98 |
Annual Sum or Average | 0.642265E+09 | 0.205237E+09 | 0.437028E+09 | 0.136047E+10 | 98657800.72 |
Minimum of Months | 45830662.07 | 11974130.69 | 32613054.57 | 94012570.89 | 3632003.09 |
Maximum of Months | 64275433.04 | 25387416.14 | 38888016.90 | 0.137455E+09 | 15818192.98 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.105389E+10 | 0.00 | 0.105389E+10 | 0.233355E+10 | 0.507966E+09 |
February | 0.101541E+10 | 0.00 | 0.101541E+10 | 0.236098E+10 | 0.347689E+09 |
March | 0.115378E+10 | 0.00 | 0.115378E+10 | 0.284470E+10 | 0.251091E+09 |
April | 0.121512E+10 | 17220475.84 | 0.119790E+10 | 0.309283E+10 | 0.101017E+09 |
May | 0.160955E+10 | 0.171466E+09 | 0.143809E+10 | 0.406517E+10 | 0.131659E+09 |
June | 0.190270E+10 | 0.384521E+09 | 0.151818E+10 | 0.466892E+10 | 0.143747E+09 |
July | 0.169068E+10 | 0.177214E+09 | 0.151347E+10 | 0.379618E+10 | 0.271110E+09 |
August | 0.139198E+10 | 59355272.39 | 0.133263E+10 | 0.317513E+10 | 0.203683E+09 |
September | 0.114689E+10 | 549193.87 | 0.114634E+10 | 0.270563E+10 | 0.195129E+09 |
October | 0.114191E+10 | 0.00 | 0.114191E+10 | 0.249341E+10 | 0.271242E+09 |
November | 0.104564E+10 | 0.00 | 0.104564E+10 | 0.230357E+10 | 0.328134E+09 |
December | 0.102384E+10 | 0.00 | 0.102384E+10 | 0.224720E+10 | 0.557174E+09 |
Annual Sum or Average | 0.153914E+11 | 0.810326E+09 | 0.145811E+11 | 0.360873E+11 | 0.330964E+10 |
Minimum of Months | 0.101541E+10 | 0.00 | 0.101541E+10 | 0.224720E+10 | 0.101017E+09 |
Maximum of Months | 0.190270E+10 | 0.384521E+09 | 0.151818E+10 | 0.466892E+10 | 0.557174E+09 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_2_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.135478E+10 | 0.456598E+09 | 0.898181E+09 | 0.275603E+10 | 0.321813E+09 |
February | 0.138764E+10 | 0.508775E+09 | 0.878863E+09 | 0.288870E+10 | 0.217597E+09 |
March | 0.167487E+10 | 0.655870E+09 | 0.101900E+10 | 0.357372E+10 | 0.154733E+09 |
April | 0.163811E+10 | 0.625825E+09 | 0.101229E+10 | 0.359263E+10 | 63629969.83 |
May | 0.145504E+10 | 0.440436E+09 | 0.101460E+10 | 0.332352E+10 | 85130818.13 |
June | 0.149975E+10 | 0.493936E+09 | 0.100581E+10 | 0.337966E+10 | 90494678.18 |
July | 0.132369E+10 | 0.296539E+09 | 0.102715E+10 | 0.280783E+10 | 0.174428E+09 |
August | 0.145675E+10 | 0.428221E+09 | 0.102853E+10 | 0.304235E+10 | 0.134021E+09 |
September | 0.132393E+10 | 0.360776E+09 | 0.963157E+09 | 0.284152E+10 | 0.131387E+09 |
October | 0.128218E+10 | 0.328027E+09 | 0.954154E+09 | 0.261996E+10 | 0.181674E+09 |
November | 0.120086E+10 | 0.331853E+09 | 0.869011E+09 | 0.246575E+10 | 0.217908E+09 |
December | 0.126985E+10 | 0.407507E+09 | 0.862347E+09 | 0.257190E+10 | 0.358252E+09 |
Annual Sum or Average | 0.168675E+11 | 0.533436E+10 | 0.115331E+11 | 0.358636E+11 | 0.213107E+10 |
Minimum of Months | 0.120086E+10 | 0.296539E+09 | 0.862347E+09 | 0.246575E+10 | 63629969.83 |
Maximum of Months | 0.167487E+10 | 0.655870E+09 | 0.102853E+10 | 0.359263E+10 | 0.358252E+09 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.279027E+10 | 0.116413E+10 | 0.162614E+10 | 0.571669E+10 | 0.517682E+09 |
February | 0.214007E+10 | 0.697740E+09 | 0.144233E+10 | 0.472538E+10 | 0.345892E+09 |
March | 0.161696E+10 | 0.217157E+09 | 0.139980E+10 | 0.396069E+10 | 0.239873E+09 |
April | 0.116663E+10 | 523706.84 | 0.116611E+10 | 0.301098E+10 | 90556702.16 |
May | 0.120634E+10 | 0.00 | 0.120634E+10 | 0.318946E+10 | 0.121279E+09 |
June | 0.116323E+10 | 0.00 | 0.116323E+10 | 0.306621E+10 | 0.126992E+09 |
July | 0.123824E+10 | 0.00 | 0.123824E+10 | 0.282716E+10 | 0.256196E+09 |
August | 0.120544E+10 | 1863017.82 | 0.120357E+10 | 0.277100E+10 | 0.188493E+09 |
September | 0.129146E+10 | 42179677.96 | 0.124928E+10 | 0.302782E+10 | 0.195707E+09 |
October | 0.174592E+10 | 0.278372E+09 | 0.146755E+10 | 0.375119E+10 | 0.286501E+09 |
November | 0.219703E+10 | 0.670283E+09 | 0.152675E+10 | 0.458465E+10 | 0.350118E+09 |
December | 0.278884E+10 | 0.118653E+10 | 0.160230E+10 | 0.562856E+10 | 0.578713E+09 |
Annual Sum or Average | 0.205504E+11 | 0.425878E+10 | 0.162916E+11 | 0.462598E+11 | 0.329800E+10 |
Minimum of Months | 0.116323E+10 | 0.00 | 0.116323E+10 | 0.277100E+10 | 90556702.16 |
Maximum of Months | 0.279027E+10 | 0.118653E+10 | 0.162614E+10 | 0.571669E+10 | 0.578713E+09 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_4_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.137268E+10 | 0.482679E+09 | 0.890005E+09 | 0.282500E+10 | 0.358950E+09 |
February | 0.136171E+10 | 0.481875E+09 | 0.879831E+09 | 0.286704E+10 | 0.245843E+09 |
March | 0.168991E+10 | 0.667480E+09 | 0.102243E+10 | 0.362113E+10 | 0.190673E+09 |
April | 0.164348E+10 | 0.629477E+09 | 0.101401E+10 | 0.357648E+10 | 79078877.32 |
May | 0.144504E+10 | 0.428097E+09 | 0.101694E+10 | 0.328074E+10 | 87035108.60 |
June | 0.151537E+10 | 0.522310E+09 | 0.993057E+09 | 0.338692E+10 | 94439705.23 |
July | 0.133499E+10 | 0.314821E+09 | 0.102017E+10 | 0.282600E+10 | 0.181994E+09 |
August | 0.145140E+10 | 0.429822E+09 | 0.102158E+10 | 0.301437E+10 | 0.139032E+09 |
September | 0.131560E+10 | 0.364888E+09 | 0.950711E+09 | 0.281146E+10 | 0.139396E+09 |
October | 0.127679E+10 | 0.329129E+09 | 0.947664E+09 | 0.260641E+10 | 0.192539E+09 |
November | 0.120497E+10 | 0.328630E+09 | 0.876335E+09 | 0.248144E+10 | 0.230944E+09 |
December | 0.127429E+10 | 0.416844E+09 | 0.857451E+09 | 0.262094E+10 | 0.390033E+09 |
Annual Sum or Average | 0.168862E+11 | 0.539605E+10 | 0.114902E+11 | 0.359179E+11 | 0.232996E+10 |
Minimum of Months | 0.120497E+10 | 0.314821E+09 | 0.857451E+09 | 0.248144E+10 | 79078877.32 |
Maximum of Months | 0.168991E+10 | 0.667480E+09 | 0.102243E+10 | 0.362113E+10 | 0.390033E+09 |
Report: WindowZoneSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 863.54 | 182.28 | 393.48 | 0.00 | 393.48 | 0.00 | 0.00 |
February | 965.67 | 137.76 | 419.73 | 0.00 | 419.73 | 0.00 | 0.00 |
March | 1049.43 | 91.61 | 430.77 | 0.00 | 430.77 | 0.00 | 0.00 |
April | 1176.13 | 39.79 | 468.79 | 6.64 | 462.15 | 0.00 | 0.00 |
May | 1501.37 | 49.18 | 600.94 | 64.02 | 536.92 | 0.00 | 0.00 |
June | 1784.44 | 56.39 | 734.07 | 148.35 | 585.72 | 0.00 | 0.00 |
July | 1403.52 | 100.59 | 631.23 | 66.16 | 565.06 | 0.00 | 0.00 |
August | 1175.08 | 74.02 | 519.71 | 22.16 | 497.55 | 0.00 | 0.00 |
September | 1030.98 | 74.63 | 442.47 | 0.21 | 442.26 | 0.00 | 0.00 |
October | 921.32 | 98.67 | 426.34 | 0.00 | 426.34 | 0.00 | 0.00 |
November | 880.03 | 120.87 | 403.41 | 0.00 | 403.41 | 0.00 | 0.00 |
December | 832.84 | 197.90 | 382.26 | 0.00 | 382.26 | 0.00 | 0.00 |
Annual Sum or Average | 1132.46 | 102.00 | 488.06 | 25.70 | 462.36 | 0.00 | 0.00 |
Minimum of Months | 832.84 | 39.79 | 382.26 | 0.00 | 382.26 | 0.00 | 0.00 |
Maximum of Months | 1784.44 | 197.90 | 734.07 | 148.35 | 585.72 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1022.76 | 115.95 | 505.82 | 170.47 | 335.34 | 0.00 | 0.00 |
February | 1186.05 | 86.25 | 573.59 | 210.31 | 363.29 | 0.00 | 0.00 |
March | 1324.15 | 56.08 | 625.33 | 244.87 | 380.45 | 0.00 | 0.00 |
April | 1373.79 | 24.91 | 631.99 | 241.44 | 390.54 | 0.00 | 0.00 |
May | 1229.74 | 31.72 | 543.25 | 164.44 | 378.81 | 0.00 | 0.00 |
June | 1292.45 | 35.50 | 578.61 | 190.56 | 388.04 | 0.00 | 0.00 |
July | 1039.27 | 64.70 | 494.21 | 110.71 | 383.49 | 0.00 | 0.00 |
August | 1128.42 | 48.69 | 543.89 | 159.88 | 384.01 | 0.00 | 0.00 |
September | 1087.19 | 50.31 | 510.78 | 139.19 | 371.59 | 0.00 | 0.00 |
October | 971.00 | 66.25 | 478.71 | 122.47 | 356.24 | 0.00 | 0.00 |
November | 944.57 | 80.66 | 463.30 | 128.03 | 335.27 | 0.00 | 0.00 |
December | 955.14 | 128.03 | 474.11 | 152.15 | 321.96 | 0.00 | 0.00 |
Annual Sum or Average | 1128.59 | 65.78 | 534.86 | 169.15 | 365.71 | 0.00 | 0.00 |
Minimum of Months | 944.57 | 24.91 | 463.30 | 110.71 | 321.96 | 0.00 | 0.00 |
Maximum of Months | 1373.79 | 128.03 | 631.99 | 244.87 | 390.54 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 2127.11 | 186.94 | 1041.77 | 434.64 | 607.13 | 0.00 | 0.00 |
February | 1943.10 | 137.31 | 884.62 | 288.42 | 596.20 | 0.00 | 0.00 |
March | 1465.24 | 86.93 | 603.70 | 81.08 | 522.62 | 0.00 | 0.00 |
April | 1144.84 | 35.40 | 450.09 | 0.20 | 449.89 | 0.00 | 0.00 |
May | 1174.88 | 44.93 | 450.40 | 0.00 | 450.40 | 0.00 | 0.00 |
June | 1166.89 | 49.64 | 448.78 | 0.00 | 448.78 | 0.00 | 0.00 |
July | 1042.58 | 94.71 | 462.31 | 0.00 | 462.31 | 0.00 | 0.00 |
August | 1024.43 | 67.86 | 450.06 | 0.70 | 449.36 | 0.00 | 0.00 |
September | 1154.90 | 74.80 | 498.25 | 16.27 | 481.97 | 0.00 | 0.00 |
October | 1389.87 | 104.53 | 651.85 | 103.93 | 547.92 | 0.00 | 0.00 |
November | 1759.49 | 130.06 | 847.62 | 258.60 | 589.02 | 0.00 | 0.00 |
December | 2095.65 | 207.55 | 1041.23 | 443.00 | 598.23 | 0.00 | 0.00 |
Annual Sum or Average | 1455.08 | 101.75 | 651.65 | 135.05 | 516.60 | 0.00 | 0.00 |
Minimum of Months | 1024.43 | 35.40 | 448.78 | 0.00 | 448.78 | 0.00 | 0.00 |
Maximum of Months | 2127.11 | 207.55 | 1041.77 | 443.00 | 607.13 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1050.72 | 128.34 | 512.50 | 180.21 | 332.29 | 0.00 | 0.00 |
February | 1179.01 | 96.89 | 562.87 | 199.19 | 363.69 | 0.00 | 0.00 |
March | 1344.08 | 69.21 | 630.94 | 249.21 | 381.73 | 0.00 | 0.00 |
April | 1369.95 | 30.70 | 634.06 | 242.85 | 391.21 | 0.00 | 0.00 |
May | 1215.70 | 31.85 | 539.52 | 159.83 | 379.68 | 0.00 | 0.00 |
June | 1296.65 | 36.25 | 584.63 | 201.51 | 383.12 | 0.00 | 0.00 |
July | 1047.60 | 66.46 | 498.43 | 117.54 | 380.89 | 0.00 | 0.00 |
August | 1119.39 | 49.62 | 541.89 | 160.48 | 381.41 | 0.00 | 0.00 |
September | 1077.28 | 52.57 | 507.56 | 140.77 | 366.79 | 0.00 | 0.00 |
October | 968.01 | 69.32 | 476.70 | 122.88 | 353.82 | 0.00 | 0.00 |
November | 952.78 | 84.55 | 464.88 | 126.79 | 338.09 | 0.00 | 0.00 |
December | 975.61 | 137.97 | 475.77 | 155.63 | 320.14 | 0.00 | 0.00 |
Annual Sum or Average | 1132.24 | 71.15 | 535.46 | 171.11 | 364.35 | 0.00 | 0.00 |
Minimum of Months | 952.78 | 30.70 | 464.88 | 117.54 | 320.14 | 0.00 | 0.00 |
Maximum of Months | 1369.95 | 137.97 | 634.06 | 249.21 | 391.21 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 868.78 | 191.10 | 393.47 | 0.00 | 393.47 | 0.00 | 0.00 |
February | 973.36 | 146.88 | 419.73 | 0.00 | 419.73 | 0.00 | 0.00 |
March | 1059.09 | 95.34 | 430.77 | 0.00 | 430.77 | 0.00 | 0.00 |
April | 1189.08 | 40.78 | 468.79 | 6.64 | 462.15 | 0.00 | 0.00 |
May | 1511.98 | 54.42 | 600.94 | 64.02 | 536.92 | 0.00 | 0.00 |
June | 1793.10 | 62.94 | 734.06 | 148.35 | 585.72 | 0.00 | 0.00 |
July | 1411.97 | 111.58 | 631.23 | 66.16 | 565.06 | 0.00 | 0.00 |
August | 1177.15 | 85.55 | 519.70 | 22.16 | 497.54 | 0.00 | 0.00 |
September | 1036.31 | 82.56 | 442.47 | 0.21 | 442.26 | 0.00 | 0.00 |
October | 927.41 | 107.03 | 426.34 | 0.00 | 426.34 | 0.00 | 0.00 |
November | 885.56 | 132.08 | 403.41 | 0.00 | 403.41 | 0.00 | 0.00 |
December | 835.55 | 213.55 | 382.25 | 0.00 | 382.25 | 0.00 | 0.00 |
Annual Sum or Average | 1139.52 | 110.35 | 488.06 | 25.70 | 462.36 | 0.00 | 0.00 |
Minimum of Months | 835.55 | 40.78 | 382.25 | 0.00 | 382.25 | 0.00 | 0.00 |
Maximum of Months | 1793.10 | 213.55 | 734.06 | 148.35 | 585.72 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1026.26 | 127.10 | 505.81 | 170.47 | 335.34 | 0.00 | 0.00 |
February | 1190.82 | 98.57 | 573.59 | 210.30 | 363.28 | 0.00 | 0.00 |
March | 1331.58 | 65.97 | 625.32 | 244.87 | 380.45 | 0.00 | 0.00 |
April | 1380.11 | 30.10 | 631.98 | 241.44 | 390.54 | 0.00 | 0.00 |
May | 1233.62 | 37.12 | 543.25 | 164.44 | 378.81 | 0.00 | 0.00 |
June | 1296.70 | 41.18 | 578.60 | 190.56 | 388.04 | 0.00 | 0.00 |
July | 1043.00 | 74.07 | 494.21 | 110.71 | 383.49 | 0.00 | 0.00 |
August | 1129.45 | 60.02 | 543.88 | 159.88 | 384.01 | 0.00 | 0.00 |
September | 1089.87 | 60.04 | 510.77 | 139.19 | 371.59 | 0.00 | 0.00 |
October | 974.73 | 76.69 | 478.71 | 122.47 | 356.24 | 0.00 | 0.00 |
November | 948.24 | 92.77 | 463.29 | 128.03 | 335.26 | 0.00 | 0.00 |
December | 957.61 | 143.19 | 474.11 | 152.14 | 321.96 | 0.00 | 0.00 |
Annual Sum or Average | 1132.53 | 75.59 | 534.86 | 169.15 | 365.71 | 0.00 | 0.00 |
Minimum of Months | 948.24 | 30.10 | 463.29 | 110.71 | 321.96 | 0.00 | 0.00 |
Maximum of Months | 1380.11 | 143.19 | 631.98 | 244.87 | 390.54 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 2115.99 | 213.69 | 1041.78 | 434.64 | 607.14 | 0.00 | 0.00 |
February | 1929.77 | 163.30 | 884.63 | 288.42 | 596.20 | 0.00 | 0.00 |
March | 1458.40 | 101.13 | 603.71 | 81.08 | 522.63 | 0.00 | 0.00 |
April | 1143.18 | 39.32 | 450.09 | 0.20 | 449.89 | 0.00 | 0.00 |
May | 1170.61 | 50.81 | 450.40 | 0.00 | 450.40 | 0.00 | 0.00 |
June | 1158.54 | 54.80 | 448.78 | 0.00 | 448.78 | 0.00 | 0.00 |
July | 1043.23 | 105.47 | 462.31 | 0.00 | 462.31 | 0.00 | 0.00 |
August | 1017.48 | 81.23 | 450.06 | 0.70 | 449.37 | 0.00 | 0.00 |
September | 1152.54 | 85.93 | 498.25 | 16.27 | 481.98 | 0.00 | 0.00 |
October | 1389.10 | 119.99 | 651.86 | 103.93 | 547.92 | 0.00 | 0.00 |
November | 1751.89 | 153.16 | 847.63 | 258.60 | 589.03 | 0.00 | 0.00 |
December | 2086.97 | 239.32 | 1041.24 | 443.01 | 598.24 | 0.00 | 0.00 |
Annual Sum or Average | 1449.19 | 117.34 | 651.65 | 135.05 | 516.61 | 0.00 | 0.00 |
Minimum of Months | 1017.48 | 39.32 | 448.78 | 0.00 | 448.78 | 0.00 | 0.00 |
Maximum of Months | 2115.99 | 239.32 | 1041.78 | 443.01 | 607.14 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1052.00 | 140.91 | 512.50 | 180.21 | 332.29 | 0.00 | 0.00 |
February | 1182.07 | 110.62 | 562.87 | 199.19 | 363.68 | 0.00 | 0.00 |
March | 1349.28 | 79.34 | 630.94 | 249.21 | 381.73 | 0.00 | 0.00 |
April | 1374.73 | 36.84 | 634.06 | 242.85 | 391.20 | 0.00 | 0.00 |
May | 1217.94 | 38.54 | 539.51 | 159.83 | 379.68 | 0.00 | 0.00 |
June | 1299.27 | 43.28 | 584.63 | 201.51 | 383.12 | 0.00 | 0.00 |
July | 1050.09 | 77.56 | 498.43 | 117.54 | 380.89 | 0.00 | 0.00 |
August | 1119.06 | 62.52 | 541.89 | 160.48 | 381.41 | 0.00 | 0.00 |
September | 1078.42 | 63.16 | 507.56 | 140.77 | 366.78 | 0.00 | 0.00 |
October | 969.07 | 81.14 | 476.70 | 122.88 | 353.81 | 0.00 | 0.00 |
November | 953.60 | 97.72 | 464.88 | 126.78 | 338.09 | 0.00 | 0.00 |
December | 975.18 | 155.27 | 475.76 | 155.63 | 320.13 | 0.00 | 0.00 |
Annual Sum or Average | 1134.22 | 82.25 | 535.45 | 171.11 | 364.35 | 0.00 | 0.00 |
Minimum of Months | 953.60 | 36.84 | 464.88 | 117.54 | 320.13 | 0.00 | 0.00 |
Maximum of Months | 1374.73 | 155.27 | 634.06 | 249.21 | 391.20 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 871.25 | 189.65 | 393.48 | 0.00 | 393.48 | 0.00 | 0.00 |
February | 975.93 | 143.72 | 419.73 | 0.00 | 419.73 | 0.00 | 0.00 |
March | 1062.09 | 93.75 | 430.77 | 0.00 | 430.77 | 0.00 | 0.00 |
April | 1193.22 | 38.97 | 468.79 | 6.64 | 462.15 | 0.00 | 0.00 |
May | 1517.76 | 49.16 | 600.94 | 64.02 | 536.92 | 0.00 | 0.00 |
June | 1801.28 | 55.46 | 734.07 | 148.35 | 585.72 | 0.00 | 0.00 |
July | 1417.33 | 101.22 | 631.23 | 66.16 | 565.06 | 0.00 | 0.00 |
August | 1185.46 | 76.05 | 519.71 | 22.16 | 497.55 | 0.00 | 0.00 |
September | 1043.84 | 75.28 | 442.47 | 0.21 | 442.26 | 0.00 | 0.00 |
October | 930.93 | 101.27 | 426.34 | 0.00 | 426.34 | 0.00 | 0.00 |
November | 888.72 | 126.59 | 403.41 | 0.00 | 403.41 | 0.00 | 0.00 |
December | 839.01 | 208.02 | 382.26 | 0.00 | 382.26 | 0.00 | 0.00 |
Annual Sum or Average | 1144.32 | 104.95 | 488.06 | 25.70 | 462.36 | 0.00 | 0.00 |
Minimum of Months | 839.01 | 38.97 | 382.26 | 0.00 | 382.26 | 0.00 | 0.00 |
Maximum of Months | 1801.28 | 208.02 | 734.07 | 148.35 | 585.72 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1028.98 | 120.15 | 505.82 | 170.47 | 335.34 | 0.00 | 0.00 |
February | 1194.07 | 89.95 | 573.59 | 210.31 | 363.29 | 0.00 | 0.00 |
March | 1334.27 | 57.77 | 625.33 | 244.87 | 380.45 | 0.00 | 0.00 |
April | 1386.05 | 24.55 | 631.99 | 241.44 | 390.54 | 0.00 | 0.00 |
May | 1240.86 | 31.78 | 543.25 | 164.44 | 378.81 | 0.00 | 0.00 |
June | 1303.88 | 34.91 | 578.61 | 190.56 | 388.04 | 0.00 | 0.00 |
July | 1048.32 | 65.12 | 494.21 | 110.71 | 383.49 | 0.00 | 0.00 |
August | 1135.88 | 50.04 | 543.89 | 159.88 | 384.01 | 0.00 | 0.00 |
September | 1096.27 | 50.69 | 510.78 | 139.19 | 371.59 | 0.00 | 0.00 |
October | 978.18 | 67.83 | 478.71 | 122.47 | 356.24 | 0.00 | 0.00 |
November | 951.29 | 84.07 | 463.30 | 128.03 | 335.27 | 0.00 | 0.00 |
December | 960.24 | 133.76 | 474.11 | 152.15 | 321.96 | 0.00 | 0.00 |
Annual Sum or Average | 1137.23 | 67.58 | 534.86 | 169.15 | 365.71 | 0.00 | 0.00 |
Minimum of Months | 951.29 | 24.55 | 463.30 | 110.71 | 321.96 | 0.00 | 0.00 |
Maximum of Months | 1386.05 | 133.76 | 631.99 | 244.87 | 390.54 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 2134.37 | 193.28 | 1041.77 | 434.64 | 607.13 | 0.00 | 0.00 |
February | 1953.28 | 142.98 | 884.62 | 288.42 | 596.20 | 0.00 | 0.00 |
March | 1478.75 | 89.56 | 603.70 | 81.08 | 522.62 | 0.00 | 0.00 |
April | 1161.64 | 34.94 | 450.09 | 0.20 | 449.89 | 0.00 | 0.00 |
May | 1190.81 | 45.28 | 450.40 | 0.00 | 450.40 | 0.00 | 0.00 |
June | 1182.95 | 48.99 | 448.78 | 0.00 | 448.78 | 0.00 | 0.00 |
July | 1055.54 | 95.65 | 462.31 | 0.00 | 462.31 | 0.00 | 0.00 |
August | 1034.57 | 70.38 | 450.06 | 0.70 | 449.36 | 0.00 | 0.00 |
September | 1168.14 | 75.50 | 498.25 | 16.27 | 481.97 | 0.00 | 0.00 |
October | 1400.53 | 106.97 | 651.85 | 103.93 | 547.92 | 0.00 | 0.00 |
November | 1768.77 | 135.08 | 847.62 | 258.60 | 589.02 | 0.00 | 0.00 |
December | 2101.46 | 216.07 | 1041.23 | 443.00 | 598.23 | 0.00 | 0.00 |
Annual Sum or Average | 1466.89 | 104.58 | 651.65 | 135.05 | 516.60 | 0.00 | 0.00 |
Minimum of Months | 1034.57 | 34.94 | 448.78 | 0.00 | 448.78 | 0.00 | 0.00 |
Maximum of Months | 2134.37 | 216.07 | 1041.77 | 443.00 | 607.13 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1054.73 | 134.02 | 512.50 | 180.21 | 332.29 | 0.00 | 0.00 |
February | 1185.12 | 101.62 | 562.87 | 199.19 | 363.69 | 0.00 | 0.00 |
March | 1351.97 | 71.19 | 630.94 | 249.21 | 381.73 | 0.00 | 0.00 |
April | 1379.81 | 30.51 | 634.06 | 242.85 | 391.21 | 0.00 | 0.00 |
May | 1224.89 | 32.50 | 539.52 | 159.83 | 379.68 | 0.00 | 0.00 |
June | 1306.68 | 36.44 | 584.63 | 201.51 | 383.12 | 0.00 | 0.00 |
July | 1055.11 | 67.95 | 498.43 | 117.54 | 380.89 | 0.00 | 0.00 |
August | 1125.44 | 51.91 | 541.89 | 160.48 | 381.41 | 0.00 | 0.00 |
September | 1084.67 | 53.78 | 507.56 | 140.77 | 366.79 | 0.00 | 0.00 |
October | 973.12 | 71.89 | 476.70 | 122.88 | 353.82 | 0.00 | 0.00 |
November | 957.35 | 89.10 | 464.88 | 126.79 | 338.09 | 0.00 | 0.00 |
December | 978.55 | 145.62 | 475.77 | 155.63 | 320.14 | 0.00 | 0.00 |
Annual Sum or Average | 1138.95 | 73.88 | 535.46 | 171.11 | 364.35 | 0.00 | 0.00 |
Minimum of Months | 957.35 | 30.51 | 464.88 | 117.54 | 320.14 | 0.00 | 0.00 |
Maximum of Months | 1379.81 | 145.62 | 634.06 | 249.21 | 391.21 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.231292E+10 | 0.488214E+09 | 0.105389E+10 | 0.00 | 0.105389E+10 | 0.00 | 0.00 |
February | 0.233615E+10 | 0.333259E+09 | 0.101541E+10 | 0.00 | 0.101541E+10 | 0.00 | 0.00 |
March | 0.281081E+10 | 0.245374E+09 | 0.115378E+10 | 0.00 | 0.115378E+10 | 0.00 | 0.00 |
April | 0.304854E+10 | 0.103128E+09 | 0.121512E+10 | 17220475.84 | 0.119790E+10 | 0.00 | 0.00 |
May | 0.402126E+10 | 0.131718E+09 | 0.160955E+10 | 0.171466E+09 | 0.143809E+10 | 0.00 | 0.00 |
June | 0.462526E+10 | 0.146162E+09 | 0.190270E+10 | 0.384521E+09 | 0.151818E+10 | 0.00 | 0.00 |
July | 0.375919E+10 | 0.269426E+09 | 0.169068E+10 | 0.177214E+09 | 0.151347E+10 | 0.00 | 0.00 |
August | 0.314733E+10 | 0.198252E+09 | 0.139198E+10 | 59355272.39 | 0.133263E+10 | 0.00 | 0.00 |
September | 0.267229E+10 | 0.193453E+09 | 0.114689E+10 | 549193.87 | 0.114634E+10 | 0.00 | 0.00 |
October | 0.246767E+10 | 0.264283E+09 | 0.114191E+10 | 0.00 | 0.114191E+10 | 0.00 | 0.00 |
November | 0.228104E+10 | 0.313299E+09 | 0.104564E+10 | 0.00 | 0.104564E+10 | 0.00 | 0.00 |
December | 0.223069E+10 | 0.530062E+09 | 0.102384E+10 | 0.00 | 0.102384E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.357131E+11 | 0.321663E+10 | 0.153914E+11 | 0.810326E+09 | 0.145811E+11 | 0.00 | 0.00 |
Minimum of Months | 0.223069E+10 | 0.103128E+09 | 0.101541E+10 | 0.00 | 0.101541E+10 | 0.00 | 0.00 |
Maximum of Months | 0.462526E+10 | 0.530062E+09 | 0.190270E+10 | 0.384521E+09 | 0.151818E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.273935E+10 | 0.310564E+09 | 0.135478E+10 | 0.456598E+09 | 0.898181E+09 | 0.00 | 0.00 |
February | 0.286929E+10 | 0.208661E+09 | 0.138764E+10 | 0.508775E+09 | 0.878863E+09 | 0.00 | 0.00 |
March | 0.354660E+10 | 0.150202E+09 | 0.167487E+10 | 0.655870E+09 | 0.101900E+10 | 0.00 | 0.00 |
April | 0.356087E+10 | 64563054.61 | 0.163811E+10 | 0.625825E+09 | 0.101229E+10 | 0.00 | 0.00 |
May | 0.329374E+10 | 84949666.38 | 0.145504E+10 | 0.440436E+09 | 0.101460E+10 | 0.00 | 0.00 |
June | 0.335002E+10 | 92006171.37 | 0.149975E+10 | 0.493936E+09 | 0.100581E+10 | 0.00 | 0.00 |
July | 0.278359E+10 | 0.173296E+09 | 0.132369E+10 | 0.296539E+09 | 0.102715E+10 | 0.00 | 0.00 |
August | 0.302235E+10 | 0.130424E+09 | 0.145675E+10 | 0.428221E+09 | 0.102853E+10 | 0.00 | 0.00 |
September | 0.281799E+10 | 0.130404E+09 | 0.132393E+10 | 0.360776E+09 | 0.963157E+09 | 0.00 | 0.00 |
October | 0.260074E+10 | 0.177444E+09 | 0.128218E+10 | 0.328027E+09 | 0.954154E+09 | 0.00 | 0.00 |
November | 0.244832E+10 | 0.209078E+09 | 0.120086E+10 | 0.331853E+09 | 0.869011E+09 | 0.00 | 0.00 |
December | 0.255824E+10 | 0.342907E+09 | 0.126985E+10 | 0.407507E+09 | 0.862347E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.355911E+11 | 0.207450E+10 | 0.168675E+11 | 0.533436E+10 | 0.115331E+11 | 0.00 | 0.00 |
Minimum of Months | 0.244832E+10 | 64563054.61 | 0.120086E+10 | 0.296539E+09 | 0.862347E+09 | 0.00 | 0.00 |
Maximum of Months | 0.356087E+10 | 0.342907E+09 | 0.167487E+10 | 0.655870E+09 | 0.102853E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.569726E+10 | 0.500710E+09 | 0.279027E+10 | 0.116413E+10 | 0.162614E+10 | 0.00 | 0.00 |
February | 0.470075E+10 | 0.332189E+09 | 0.214007E+10 | 0.697740E+09 | 0.144233E+10 | 0.00 | 0.00 |
March | 0.392450E+10 | 0.232827E+09 | 0.161696E+10 | 0.217157E+09 | 0.139980E+10 | 0.00 | 0.00 |
April | 0.296743E+10 | 91754055.95 | 0.116663E+10 | 523706.84 | 0.116611E+10 | 0.00 | 0.00 |
May | 0.314679E+10 | 0.120335E+09 | 0.120634E+10 | 0.00 | 0.120634E+10 | 0.00 | 0.00 |
June | 0.302458E+10 | 0.128664E+09 | 0.116323E+10 | 0.00 | 0.116323E+10 | 0.00 | 0.00 |
July | 0.279245E+10 | 0.253675E+09 | 0.123824E+10 | 0.00 | 0.123824E+10 | 0.00 | 0.00 |
August | 0.274382E+10 | 0.181770E+09 | 0.120544E+10 | 1863017.82 | 0.120357E+10 | 0.00 | 0.00 |
September | 0.299349E+10 | 0.193885E+09 | 0.129146E+10 | 42179677.96 | 0.124928E+10 | 0.00 | 0.00 |
October | 0.372263E+10 | 0.279971E+09 | 0.174592E+10 | 0.278372E+09 | 0.146755E+10 | 0.00 | 0.00 |
November | 0.456060E+10 | 0.337103E+09 | 0.219703E+10 | 0.670283E+09 | 0.152675E+10 | 0.00 | 0.00 |
December | 0.561299E+10 | 0.555893E+09 | 0.278884E+10 | 0.118653E+10 | 0.160230E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.458873E+11 | 0.320878E+10 | 0.205504E+11 | 0.425878E+10 | 0.162916E+11 | 0.00 | 0.00 |
Minimum of Months | 0.274382E+10 | 91754055.95 | 0.116323E+10 | 0.00 | 0.116323E+10 | 0.00 | 0.00 |
Maximum of Months | 0.569726E+10 | 0.555893E+09 | 0.279027E+10 | 0.118653E+10 | 0.162614E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.281425E+10 | 0.343759E+09 | 0.137268E+10 | 0.482679E+09 | 0.890005E+09 | 0.00 | 0.00 |
February | 0.285225E+10 | 0.234408E+09 | 0.136171E+10 | 0.481875E+09 | 0.879831E+09 | 0.00 | 0.00 |
March | 0.359998E+10 | 0.185381E+09 | 0.168991E+10 | 0.667480E+09 | 0.102243E+10 | 0.00 | 0.00 |
April | 0.355090E+10 | 79565179.32 | 0.164348E+10 | 0.629477E+09 | 0.101401E+10 | 0.00 | 0.00 |
May | 0.325613E+10 | 85312582.07 | 0.144504E+10 | 0.428097E+09 | 0.101694E+10 | 0.00 | 0.00 |
June | 0.336093E+10 | 93965896.00 | 0.151537E+10 | 0.522310E+09 | 0.993057E+09 | 0.00 | 0.00 |
July | 0.280588E+10 | 0.178012E+09 | 0.133499E+10 | 0.314821E+09 | 0.102017E+10 | 0.00 | 0.00 |
August | 0.299816E+10 | 0.132907E+09 | 0.145140E+10 | 0.429822E+09 | 0.102158E+10 | 0.00 | 0.00 |
September | 0.279230E+10 | 0.136254E+09 | 0.131560E+10 | 0.364888E+09 | 0.950711E+09 | 0.00 | 0.00 |
October | 0.259272E+10 | 0.185654E+09 | 0.127679E+10 | 0.329129E+09 | 0.947664E+09 | 0.00 | 0.00 |
November | 0.246960E+10 | 0.219156E+09 | 0.120497E+10 | 0.328630E+09 | 0.876335E+09 | 0.00 | 0.00 |
December | 0.261307E+10 | 0.369551E+09 | 0.127429E+10 | 0.416844E+09 | 0.857451E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.357062E+11 | 0.224392E+10 | 0.168862E+11 | 0.539605E+10 | 0.114902E+11 | 0.00 | 0.00 |
Minimum of Months | 0.246960E+10 | 79565179.32 | 0.120497E+10 | 0.314821E+09 | 0.857451E+09 | 0.00 | 0.00 |
Maximum of Months | 0.359998E+10 | 0.369551E+09 | 0.168991E+10 | 0.667480E+09 | 0.102243E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.232694E+10 | 0.511835E+09 | 0.105388E+10 | 0.00 | 0.105388E+10 | 0.00 | 0.00 |
February | 0.235474E+10 | 0.355340E+09 | 0.101541E+10 | 0.00 | 0.101541E+10 | 0.00 | 0.00 |
March | 0.283668E+10 | 0.255359E+09 | 0.115377E+10 | 0.00 | 0.115377E+10 | 0.00 | 0.00 |
April | 0.308209E+10 | 0.105707E+09 | 0.121511E+10 | 17220386.61 | 0.119789E+10 | 0.00 | 0.00 |
May | 0.404969E+10 | 0.145770E+09 | 0.160955E+10 | 0.171465E+09 | 0.143808E+10 | 0.00 | 0.00 |
June | 0.464771E+10 | 0.163143E+09 | 0.190269E+10 | 0.384519E+09 | 0.151818E+10 | 0.00 | 0.00 |
July | 0.378183E+10 | 0.298864E+09 | 0.169068E+10 | 0.177213E+09 | 0.151346E+10 | 0.00 | 0.00 |
August | 0.315287E+10 | 0.229127E+09 | 0.139198E+10 | 59354964.82 | 0.133262E+10 | 0.00 | 0.00 |
September | 0.268610E+10 | 0.213996E+09 | 0.114689E+10 | 549191.03 | 0.114634E+10 | 0.00 | 0.00 |
October | 0.248398E+10 | 0.286661E+09 | 0.114191E+10 | 0.00 | 0.114191E+10 | 0.00 | 0.00 |
November | 0.229536E+10 | 0.342359E+09 | 0.104564E+10 | 0.00 | 0.104564E+10 | 0.00 | 0.00 |
December | 0.223793E+10 | 0.571976E+09 | 0.102383E+10 | 0.00 | 0.102383E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.359359E+11 | 0.348014E+10 | 0.153913E+11 | 0.810322E+09 | 0.145810E+11 | 0.00 | 0.00 |
Minimum of Months | 0.223793E+10 | 0.105707E+09 | 0.101541E+10 | 0.00 | 0.101541E+10 | 0.00 | 0.00 |
Maximum of Months | 0.464771E+10 | 0.571976E+09 | 0.190269E+10 | 0.384519E+09 | 0.151818E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.274872E+10 | 0.340425E+09 | 0.135477E+10 | 0.456594E+09 | 0.898176E+09 | 0.00 | 0.00 |
February | 0.288083E+10 | 0.238454E+09 | 0.138763E+10 | 0.508770E+09 | 0.878858E+09 | 0.00 | 0.00 |
March | 0.356651E+10 | 0.176682E+09 | 0.167486E+10 | 0.655864E+09 | 0.101900E+10 | 0.00 | 0.00 |
April | 0.357726E+10 | 78014661.64 | 0.163810E+10 | 0.625819E+09 | 0.101228E+10 | 0.00 | 0.00 |
May | 0.330414E+10 | 99411016.79 | 0.145503E+10 | 0.440432E+09 | 0.101460E+10 | 0.00 | 0.00 |
June | 0.336104E+10 | 0.106750E+09 | 0.149974E+10 | 0.493931E+09 | 0.100581E+10 | 0.00 | 0.00 |
July | 0.279357E+10 | 0.198391E+09 | 0.132368E+10 | 0.296536E+09 | 0.102715E+10 | 0.00 | 0.00 |
August | 0.302512E+10 | 0.160746E+09 | 0.145674E+10 | 0.428216E+09 | 0.102852E+10 | 0.00 | 0.00 |
September | 0.282493E+10 | 0.155621E+09 | 0.132392E+10 | 0.360773E+09 | 0.963151E+09 | 0.00 | 0.00 |
October | 0.261073E+10 | 0.205398E+09 | 0.128217E+10 | 0.328023E+09 | 0.954148E+09 | 0.00 | 0.00 |
November | 0.245783E+10 | 0.240464E+09 | 0.120086E+10 | 0.331850E+09 | 0.869006E+09 | 0.00 | 0.00 |
December | 0.256487E+10 | 0.383514E+09 | 0.126984E+10 | 0.407503E+09 | 0.862342E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.357155E+11 | 0.238387E+10 | 0.168673E+11 | 0.533431E+10 | 0.115330E+11 | 0.00 | 0.00 |
Minimum of Months | 0.245783E+10 | 78014661.64 | 0.120086E+10 | 0.296536E+09 | 0.862342E+09 | 0.00 | 0.00 |
Maximum of Months | 0.357726E+10 | 0.383514E+09 | 0.167486E+10 | 0.655864E+09 | 0.102852E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.566748E+10 | 0.572341E+09 | 0.279029E+10 | 0.116414E+10 | 0.162615E+10 | 0.00 | 0.00 |
February | 0.466849E+10 | 0.395046E+09 | 0.214009E+10 | 0.697748E+09 | 0.144234E+10 | 0.00 | 0.00 |
March | 0.390617E+10 | 0.270878E+09 | 0.161697E+10 | 0.217160E+09 | 0.139981E+10 | 0.00 | 0.00 |
April | 0.296313E+10 | 0.101928E+09 | 0.116664E+10 | 523712.94 | 0.116612E+10 | 0.00 | 0.00 |
May | 0.313536E+10 | 0.136097E+09 | 0.120635E+10 | 0.00 | 0.120635E+10 | 0.00 | 0.00 |
June | 0.300295E+10 | 0.142041E+09 | 0.116323E+10 | 0.00 | 0.116323E+10 | 0.00 | 0.00 |
July | 0.279420E+10 | 0.282491E+09 | 0.123825E+10 | 0.00 | 0.123825E+10 | 0.00 | 0.00 |
August | 0.272523E+10 | 0.217568E+09 | 0.120544E+10 | 1863039.51 | 0.120358E+10 | 0.00 | 0.00 |
September | 0.298737E+10 | 0.222726E+09 | 0.129146E+10 | 42180169.06 | 0.124928E+10 | 0.00 | 0.00 |
October | 0.372056E+10 | 0.321391E+09 | 0.174593E+10 | 0.278375E+09 | 0.146756E+10 | 0.00 | 0.00 |
November | 0.454089E+10 | 0.396988E+09 | 0.219705E+10 | 0.670291E+09 | 0.152676E+10 | 0.00 | 0.00 |
December | 0.558974E+10 | 0.641005E+09 | 0.278887E+10 | 0.118655E+10 | 0.160232E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.457016E+11 | 0.370050E+10 | 0.205506E+11 | 0.425883E+10 | 0.162917E+11 | 0.00 | 0.00 |
Minimum of Months | 0.272523E+10 | 0.101928E+09 | 0.116323E+10 | 0.00 | 0.116323E+10 | 0.00 | 0.00 |
Maximum of Months | 0.566748E+10 | 0.641005E+09 | 0.279029E+10 | 0.118655E+10 | 0.162615E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.281768E+10 | 0.377410E+09 | 0.137267E+10 | 0.482674E+09 | 0.890000E+09 | 0.00 | 0.00 |
February | 0.285966E+10 | 0.267622E+09 | 0.136170E+10 | 0.481870E+09 | 0.879826E+09 | 0.00 | 0.00 |
March | 0.361390E+10 | 0.212510E+09 | 0.168990E+10 | 0.667473E+09 | 0.102242E+10 | 0.00 | 0.00 |
April | 0.356330E+10 | 95490912.77 | 0.164347E+10 | 0.629471E+09 | 0.101400E+10 | 0.00 | 0.00 |
May | 0.326214E+10 | 0.103226E+09 | 0.144503E+10 | 0.428093E+09 | 0.101693E+10 | 0.00 | 0.00 |
June | 0.336770E+10 | 0.112188E+09 | 0.151536E+10 | 0.522305E+09 | 0.993051E+09 | 0.00 | 0.00 |
July | 0.281257E+10 | 0.207744E+09 | 0.133498E+10 | 0.314818E+09 | 0.102016E+10 | 0.00 | 0.00 |
August | 0.299730E+10 | 0.167451E+09 | 0.145139E+10 | 0.429818E+09 | 0.102157E+10 | 0.00 | 0.00 |
September | 0.279527E+10 | 0.163714E+09 | 0.131559E+10 | 0.364885E+09 | 0.950705E+09 | 0.00 | 0.00 |
October | 0.259555E+10 | 0.217324E+09 | 0.127678E+10 | 0.329125E+09 | 0.947658E+09 | 0.00 | 0.00 |
November | 0.247173E+10 | 0.253296E+09 | 0.120496E+10 | 0.328627E+09 | 0.876330E+09 | 0.00 | 0.00 |
December | 0.261192E+10 | 0.415883E+09 | 0.127429E+10 | 0.416840E+09 | 0.857446E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.357687E+11 | 0.259386E+10 | 0.168861E+11 | 0.539600E+10 | 0.114901E+11 | 0.00 | 0.00 |
Minimum of Months | 0.247173E+10 | 95490912.77 | 0.120496E+10 | 0.314818E+09 | 0.857446E+09 | 0.00 | 0.00 |
Maximum of Months | 0.361390E+10 | 0.415883E+09 | 0.168990E+10 | 0.667473E+09 | 0.102242E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.233355E+10 | 0.507966E+09 | 0.105389E+10 | 0.00 | 0.105389E+10 | 0.00 | 0.00 |
February | 0.236098E+10 | 0.347689E+09 | 0.101541E+10 | 0.00 | 0.101541E+10 | 0.00 | 0.00 |
March | 0.284470E+10 | 0.251091E+09 | 0.115378E+10 | 0.00 | 0.115378E+10 | 0.00 | 0.00 |
April | 0.309283E+10 | 0.101017E+09 | 0.121512E+10 | 17220475.84 | 0.119790E+10 | 0.00 | 0.00 |
May | 0.406517E+10 | 0.131659E+09 | 0.160955E+10 | 0.171466E+09 | 0.143809E+10 | 0.00 | 0.00 |
June | 0.466892E+10 | 0.143747E+09 | 0.190270E+10 | 0.384521E+09 | 0.151818E+10 | 0.00 | 0.00 |
July | 0.379618E+10 | 0.271110E+09 | 0.169068E+10 | 0.177214E+09 | 0.151347E+10 | 0.00 | 0.00 |
August | 0.317513E+10 | 0.203683E+09 | 0.139198E+10 | 59355272.39 | 0.133263E+10 | 0.00 | 0.00 |
September | 0.270563E+10 | 0.195129E+09 | 0.114689E+10 | 549193.87 | 0.114634E+10 | 0.00 | 0.00 |
October | 0.249341E+10 | 0.271242E+09 | 0.114191E+10 | 0.00 | 0.114191E+10 | 0.00 | 0.00 |
November | 0.230357E+10 | 0.328134E+09 | 0.104564E+10 | 0.00 | 0.104564E+10 | 0.00 | 0.00 |
December | 0.224720E+10 | 0.557174E+09 | 0.102384E+10 | 0.00 | 0.102384E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.360873E+11 | 0.330964E+10 | 0.153914E+11 | 0.810326E+09 | 0.145811E+11 | 0.00 | 0.00 |
Minimum of Months | 0.224720E+10 | 0.101017E+09 | 0.101541E+10 | 0.00 | 0.101541E+10 | 0.00 | 0.00 |
Maximum of Months | 0.466892E+10 | 0.557174E+09 | 0.190270E+10 | 0.384521E+09 | 0.151818E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.275603E+10 | 0.321813E+09 | 0.135478E+10 | 0.456598E+09 | 0.898181E+09 | 0.00 | 0.00 |
February | 0.288870E+10 | 0.217597E+09 | 0.138764E+10 | 0.508775E+09 | 0.878863E+09 | 0.00 | 0.00 |
March | 0.357372E+10 | 0.154733E+09 | 0.167487E+10 | 0.655870E+09 | 0.101900E+10 | 0.00 | 0.00 |
April | 0.359263E+10 | 63629969.83 | 0.163811E+10 | 0.625825E+09 | 0.101229E+10 | 0.00 | 0.00 |
May | 0.332352E+10 | 85130818.13 | 0.145504E+10 | 0.440436E+09 | 0.101460E+10 | 0.00 | 0.00 |
June | 0.337966E+10 | 90494678.18 | 0.149975E+10 | 0.493936E+09 | 0.100581E+10 | 0.00 | 0.00 |
July | 0.280783E+10 | 0.174428E+09 | 0.132369E+10 | 0.296539E+09 | 0.102715E+10 | 0.00 | 0.00 |
August | 0.304235E+10 | 0.134021E+09 | 0.145675E+10 | 0.428221E+09 | 0.102853E+10 | 0.00 | 0.00 |
September | 0.284152E+10 | 0.131387E+09 | 0.132393E+10 | 0.360776E+09 | 0.963157E+09 | 0.00 | 0.00 |
October | 0.261996E+10 | 0.181674E+09 | 0.128218E+10 | 0.328027E+09 | 0.954154E+09 | 0.00 | 0.00 |
November | 0.246575E+10 | 0.217908E+09 | 0.120086E+10 | 0.331853E+09 | 0.869011E+09 | 0.00 | 0.00 |
December | 0.257190E+10 | 0.358252E+09 | 0.126985E+10 | 0.407507E+09 | 0.862347E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.358636E+11 | 0.213107E+10 | 0.168675E+11 | 0.533436E+10 | 0.115331E+11 | 0.00 | 0.00 |
Minimum of Months | 0.246575E+10 | 63629969.83 | 0.120086E+10 | 0.296539E+09 | 0.862347E+09 | 0.00 | 0.00 |
Maximum of Months | 0.359263E+10 | 0.358252E+09 | 0.167487E+10 | 0.655870E+09 | 0.102853E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.571669E+10 | 0.517682E+09 | 0.279027E+10 | 0.116413E+10 | 0.162614E+10 | 0.00 | 0.00 |
February | 0.472538E+10 | 0.345892E+09 | 0.214007E+10 | 0.697740E+09 | 0.144233E+10 | 0.00 | 0.00 |
March | 0.396069E+10 | 0.239873E+09 | 0.161696E+10 | 0.217157E+09 | 0.139980E+10 | 0.00 | 0.00 |
April | 0.301098E+10 | 90556702.16 | 0.116663E+10 | 523706.84 | 0.116611E+10 | 0.00 | 0.00 |
May | 0.318946E+10 | 0.121279E+09 | 0.120634E+10 | 0.00 | 0.120634E+10 | 0.00 | 0.00 |
June | 0.306621E+10 | 0.126992E+09 | 0.116323E+10 | 0.00 | 0.116323E+10 | 0.00 | 0.00 |
July | 0.282716E+10 | 0.256196E+09 | 0.123824E+10 | 0.00 | 0.123824E+10 | 0.00 | 0.00 |
August | 0.277100E+10 | 0.188493E+09 | 0.120544E+10 | 1863017.82 | 0.120357E+10 | 0.00 | 0.00 |
September | 0.302782E+10 | 0.195707E+09 | 0.129146E+10 | 42179677.96 | 0.124928E+10 | 0.00 | 0.00 |
October | 0.375119E+10 | 0.286501E+09 | 0.174592E+10 | 0.278372E+09 | 0.146755E+10 | 0.00 | 0.00 |
November | 0.458465E+10 | 0.350118E+09 | 0.219703E+10 | 0.670283E+09 | 0.152675E+10 | 0.00 | 0.00 |
December | 0.562856E+10 | 0.578713E+09 | 0.278884E+10 | 0.118653E+10 | 0.160230E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.462598E+11 | 0.329800E+10 | 0.205504E+11 | 0.425878E+10 | 0.162916E+11 | 0.00 | 0.00 |
Minimum of Months | 0.277100E+10 | 90556702.16 | 0.116323E+10 | 0.00 | 0.116323E+10 | 0.00 | 0.00 |
Maximum of Months | 0.571669E+10 | 0.578713E+09 | 0.279027E+10 | 0.118653E+10 | 0.162614E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.282500E+10 | 0.358950E+09 | 0.137268E+10 | 0.482679E+09 | 0.890005E+09 | 0.00 | 0.00 |
February | 0.286704E+10 | 0.245843E+09 | 0.136171E+10 | 0.481875E+09 | 0.879831E+09 | 0.00 | 0.00 |
March | 0.362113E+10 | 0.190673E+09 | 0.168991E+10 | 0.667480E+09 | 0.102243E+10 | 0.00 | 0.00 |
April | 0.357648E+10 | 79078877.32 | 0.164348E+10 | 0.629477E+09 | 0.101401E+10 | 0.00 | 0.00 |
May | 0.328074E+10 | 87035108.60 | 0.144504E+10 | 0.428097E+09 | 0.101694E+10 | 0.00 | 0.00 |
June | 0.338692E+10 | 94439705.23 | 0.151537E+10 | 0.522310E+09 | 0.993057E+09 | 0.00 | 0.00 |
July | 0.282600E+10 | 0.181994E+09 | 0.133499E+10 | 0.314821E+09 | 0.102017E+10 | 0.00 | 0.00 |
August | 0.301437E+10 | 0.139032E+09 | 0.145140E+10 | 0.429822E+09 | 0.102158E+10 | 0.00 | 0.00 |
September | 0.281146E+10 | 0.139396E+09 | 0.131560E+10 | 0.364888E+09 | 0.950711E+09 | 0.00 | 0.00 |
October | 0.260641E+10 | 0.192539E+09 | 0.127679E+10 | 0.329129E+09 | 0.947664E+09 | 0.00 | 0.00 |
November | 0.248144E+10 | 0.230944E+09 | 0.120497E+10 | 0.328630E+09 | 0.876335E+09 | 0.00 | 0.00 |
December | 0.262094E+10 | 0.390033E+09 | 0.127429E+10 | 0.416844E+09 | 0.857451E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.359179E+11 | 0.232996E+10 | 0.168862E+11 | 0.539605E+10 | 0.114902E+11 | 0.00 | 0.00 |
Minimum of Months | 0.248144E+10 | 79078877.32 | 0.120497E+10 | 0.314821E+09 | 0.857451E+09 | 0.00 | 0.00 |
Maximum of Months | 0.362113E+10 | 0.390033E+09 | 0.168991E+10 | 0.667480E+09 | 0.102243E+10 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | 26.42 | 22.38 | 20.70 | 2.25 | 18.66 | 103.85 | 146.57 | 0.01 |
February | 27.50 | 22.91 | 21.01 | 2.37 | 18.54 | 110.59 | 164.59 | 0.00 |
March | 28.33 | 23.63 | 21.77 | 3.67 | 19.85 | 110.33 | 194.39 | 0.01 |
April | 29.15 | 25.37 | 24.04 | 2.98 | 21.51 | 118.69 | 185.56 | 0.03 |
May | 29.01 | 26.53 | 25.72 | 3.19 | 23.00 | 127.71 | 124.87 | 0.08 |
June | 28.86 | 26.50 | 25.74 | 3.10 | 22.78 | 123.38 | 156.09 | 0.05 |
July | 27.25 | 24.29 | 23.20 | 2.32 | 21.53 | 137.39 | 88.28 | 0.02 |
August | 27.54 | 25.86 | 25.31 | 3.22 | 21.55 | 129.55 | 122.00 | 0.07 |
September | 27.58 | 25.59 | 24.93 | 2.22 | 22.01 | 128.30 | 103.37 | 0.04 |
October | 26.89 | 25.07 | 24.46 | 2.18 | 21.39 | 123.79 | 92.41 | 0.11 |
November | 26.68 | 24.14 | 23.20 | 1.94 | 20.29 | 113.70 | 103.30 | 0.02 |
December | 25.97 | 22.85 | 21.57 | 2.00 | 18.63 | 101.83 | 131.96 | 0.00 |
Annual Sum or Average | 27.59 | 24.60 | 23.48 | 2.62 | 20.82 | 119.14 | 134.17 | 0.04 |
Minimum of Months | 25.97 | 22.38 | 20.70 | 1.94 | 18.54 | 101.83 | 88.28 | 0.00 |
Maximum of Months | 29.15 | 26.53 | 25.74 | 3.67 | 23.00 | 137.39 | 194.39 | 0.11 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 34.10 | 04-JAN-12:00 | 23.67 | 19.40 | 5.00 | 24.66 | 266.50 | 576.50 |
February | 35.00 | 21-FEB-13:00 | 22.02 | 16.00 | 2.10 | 24.16 | 230.00 | 672.50 |
March | 36.40 | 21-MAR-12:00 | 23.01 | 17.00 | 5.00 | 26.97 | 269.50 | 658.50 |
April | 35.50 | 01-APR-13:00 | 26.96 | 24.00 | 2.50 | 27.14 | 295.50 | 519.50 |
May | 37.60 | 06-MAY-12:00 | 26.43 | 22.60 | 4.00 | 29.39 | 317.00 | 525.50 |
June | 36.00 | 12-JUN-14:00 | 27.60 | 25.00 | 4.00 | 28.43 | 235.00 | 472.00 |
July | 33.20 | 15-JUL-15:00 | 25.63 | 23.00 | 2.00 | 27.95 | 219.00 | 181.00 |
August | 34.00 | 10-AUG-13:00 | 27.86 | 26.00 | 5.00 | 26.65 | 344.50 | 278.50 |
September | 34.00 | 06-SEP-13:00 | 26.51 | 24.00 | 4.00 | 25.00 | 258.00 | 581.50 |
October | 33.00 | 04-OCT-13:00 | 26.23 | 24.00 | 4.00 | 25.16 | 303.00 | 428.50 |
November | 34.30 | 18-NOV-12:00 | 25.34 | 22.20 | 3.00 | 25.49 | 289.50 | 511.50 |
December | 33.00 | 07-DEC-13:00 | 23.23 | 19.00 | 3.00 | 22.98 | 215.00 | 596.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 33.00 | 22.02 | 16.00 | 2.00 | 22.98 | 215.00 | 181.00 | |
Maximum of Months | 37.60 | 27.86 | 26.00 | 5.00 | 29.39 | 344.50 | 672.50 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 18.70 | 23-JAN-05:00 | 16.92 | 16.00 | 2.00 | 7.75 | 0.00 | 0.00 |
February | 20.30 | 21-FEB-09:00 | 19.04 | 18.40 | 2.00 | 10.50 | 258.50 | 564.00 |
March | 22.00 | 03-MAR-05:00 | 19.94 | 19.00 | 3.00 | 13.35 | 0.00 | 0.00 |
April | 22.90 | 14-APR-15:00 | 22.90 | 22.90 | 3.00 | 14.65 | 199.50 | 264.50 |
May | 22.00 | 10-MAY-19:00 | 22.00 | 22.00 | 2.00 | 18.28 | 0.00 | 0.00 |
June | 23.00 | 20-JUN-23:00 | 23.00 | 23.00 | 2.00 | 19.35 | 0.00 | 0.00 |
July | 23.00 | 13-JUL-04:00 | 22.27 | 22.00 | 0.00 | 13.91 | 0.00 | 0.00 |
August | 22.00 | 20-AUG-10:00 | 22.00 | 22.00 | 5.00 | 18.28 | 430.50 | 41.50 |
September | 22.90 | 19-SEP-03:00 | 22.78 | 22.78 | 0.00 | 21.27 | 0.00 | 0.00 |
October | 22.50 | 23-OCT-04:00 | 22.50 | 22.50 | 2.80 | 18.82 | 0.00 | 0.00 |
November | 20.00 | 25-NOV-04:00 | 18.63 | 18.00 | 2.00 | 10.69 | 0.00 | 0.00 |
December | 18.00 | 21-DEC-04:00 | 17.36 | 17.00 | 3.00 | 9.13 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 18.00 | 16.92 | 16.00 | 0.00 | 7.75 | 0.00 | 0.00 | |
Maximum of Months | 23.00 | 23.00 | 23.00 | 5.00 | 21.27 | 430.50 | 564.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 25.53 | 12-JAN-12:00 | 32.40 | 23.10 | 2.00 | 25.00 | 353.00 | 347.00 |
February | 26.17 | 14-FEB-15:00 | 32.30 | 24.20 | 2.00 | 25.16 | 200.00 | 199.00 |
March | 26.28 | 27-MAR-12:00 | 34.20 | 23.60 | 4.00 | 26.32 | 326.00 | 535.00 |
April | 27.93 | 10-APR-16:49 | 31.52 | 26.85 | 4.08 | 27.70 | 110.67 | 57.00 |
May | 29.00 | 28-MAY-20:00 | 29.00 | 29.00 | 3.00 | 22.47 | 0.00 | 0.00 |
June | 30.11 | 15-JUN-09:00 | 33.20 | 29.20 | 5.00 | 26.48 | 320.50 | 421.00 |
July | 26.43 | 20-JUL-14:00 | 32.80 | 24.20 | 1.00 | 26.65 | 305.00 | 253.00 |
August | 28.81 | 14-AUG-16:00 | 32.00 | 28.00 | 1.00 | 25.16 | 107.50 | 223.00 |
September | 30.06 | 30-SEP-10:00 | 32.80 | 29.40 | 3.00 | 25.66 | 398.00 | 359.50 |
October | 27.36 | 16-OCT-14:00 | 31.50 | 26.00 | 3.00 | 24.16 | 239.00 | 346.50 |
November | 27.56 | 10-NOV-12:00 | 31.00 | 26.40 | 6.00 | 28.11 | 388.00 | 95.50 |
December | 26.86 | 03-DEC-12:00 | 31.50 | 25.30 | 1.00 | 23.49 | 301.00 | 468.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 25.53 | 29.00 | 23.10 | 1.00 | 22.47 | 0.00 | 0.00 | |
Maximum of Months | 30.11 | 34.20 | 29.40 | 6.00 | 28.11 | 398.00 | 535.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 24.20 | 09-JAN-21:00 | 26.50 | 24.77 | 4.00 | 25.16 | 0.00 | 0.00 |
February | 24.40 | 15-FEB-18:00 | 28.30 | 25.33 | 4.00 | 20.75 | 0.00 | 0.00 |
March | 25.30 | 28-MAR-06:00 | 27.20 | 25.72 | 3.00 | 19.87 | 103.00 | 28.00 |
April | 27.00 | 10-APR-17:00 | 30.50 | 27.87 | 4.50 | 25.00 | 20.00 | 20.50 |
May | 29.00 | 28-MAY-20:00 | 29.00 | 29.00 | 3.00 | 22.47 | 0.00 | 0.00 |
June | 29.20 | 15-JUN-09:00 | 33.20 | 30.11 | 5.00 | 26.48 | 320.50 | 421.00 |
July | 26.00 | 10-JUL-14:00 | 26.50 | 26.11 | 2.30 | 23.49 | 286.00 | 36.50 |
August | 28.00 | 02-AUG-10:00 | 31.00 | 28.65 | 4.00 | 24.16 | 419.00 | 195.50 |
September | 29.40 | 30-SEP-10:00 | 32.80 | 30.06 | 3.00 | 25.66 | 398.00 | 359.50 |
October | 26.50 | 16-OCT-08:00 | 29.00 | 27.04 | 2.50 | 21.78 | 300.00 | 326.00 |
November | 26.40 | 10-NOV-12:00 | 31.00 | 27.56 | 6.00 | 28.11 | 388.00 | 95.50 |
December | 26.00 | 10-DEC-17:00 | 29.00 | 26.74 | 3.00 | 21.78 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 24.20 | 26.50 | 24.77 | 2.30 | 19.87 | 0.00 | 0.00 | |
Maximum of Months | 29.40 | 33.20 | 30.11 | 6.00 | 28.11 | 419.00 | 421.00 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 29.71 | 38.82 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 29.90 | 44.34 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 30.35 | 50.49 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 30.97 | 51.18 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 31.58 | 43.47 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 32.02 | 46.77 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 32.16 | 39.95 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 31.97 | 43.65 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 31.50 | 40.53 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 30.87 | 37.35 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 30.27 | 35.77 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 29.84 | 36.19 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 30.93 | 42.35 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 29.71 | 35.77 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 32.16 | 51.18 | 0.00 |
Report: WaterHeaterReportMonthly
For: SWHSYS1 WATER HEATER
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.345472E+10 | -0.276652E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -688192033.5 | 58.98 | 0.00 | 0.00 |
February | 0.312029E+10 | -0.249822E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -622070961.0 | 58.98 | 0.00 | 0.00 |
March | 0.360152E+10 | -0.291081E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -690707290.7 | 58.98 | 0.00 | 0.00 |
April | 0.323045E+10 | -0.256271E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -667739840.8 | 58.98 | 0.00 | 0.00 |
May | 0.337918E+10 | -0.268896E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -690224017.9 | 58.98 | 0.00 | 0.00 |
June | 0.329959E+10 | -0.263167E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -667919567.1 | 58.98 | 0.00 | 0.00 |
July | 0.315508E+10 | -0.246654E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -688535106.8 | 58.98 | 0.00 | 0.00 |
August | 0.343717E+10 | -0.274707E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -690105910.3 | 58.98 | 0.00 | 0.00 |
September | 0.318328E+10 | -0.251590E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -667377796.7 | 58.98 | 0.00 | 0.00 |
October | 0.334475E+10 | -0.265678E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -687975744.2 | 58.98 | 0.00 | 0.00 |
November | 0.333488E+10 | -0.266913E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -665748728.3 | 58.98 | 0.00 | 0.00 |
December | 0.336886E+10 | -0.267997E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -688893972.9 | 58.98 | 0.00 | 0.00 |
Annual Sum or Average | 0.399098E+11 | -0.317943E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.811549E+10 | 58.98 | 0.00 | 0.00 |
Minimum of Months | 0.312029E+10 | -0.291081E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -690707290.7 | 58.98 | 0.00 | 0.00 |
Maximum of Months | 0.360152E+10 | -0.246654E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -622070961.0 | 58.98 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_1_DAYLCTRL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 350.67 | 0.50 | 0.48 | 01-JAN-07:49 | 2004.38 | 24.45 | 147.00 | 321.33 | 980.17 | 24.47 | 235.83 | 307.17 |
February | 321.17 | 0.51 | 0.48 | 01-FEB-07:10 | 1569.99 | 17.92 | 0.00 | 292.00 | 825.41 | 20.66 | 125.33 | 268.17 |
March | 361.17 | 0.51 | 0.48 | 01-MAR-07:49 | 1180.40 | 17.68 | 0.00 | 321.83 | 656.72 | 20.34 | 69.83 | 291.50 |
April | 358.33 | 0.51 | 0.48 | 01-APR-07:10 | 965.71 | 17.27 | 0.00 | 317.50 | 548.48 | 19.97 | 0.00 | 277.17 |
May | 376.33 | 0.52 | 0.48 | 01-MAY-06:00 | 829.02 | 16.12 | 0.00 | 323.83 | 460.45 | 18.77 | 0.00 | 268.50 |
June | 370.50 | 0.52 | 0.48 | 01-JUN-07:49 | 806.72 | 16.27 | 0.00 | 315.33 | 463.80 | 19.00 | 0.00 | 264.50 |
July | 383.17 | 0.52 | 0.48 | 01-JUL-07:19 | 786.68 | 15.66 | 0.00 | 320.67 | 425.85 | 18.27 | 0.00 | 261.17 |
August | 369.33 | 0.51 | 0.48 | 01-AUG-07:10 | 928.51 | 16.67 | 0.00 | 323.33 | 507.09 | 19.31 | 2.00 | 275.50 |
September | 357.83 | 0.52 | 0.48 | 01-SEP-06:00 | 1053.15 | 16.58 | 0.00 | 308.67 | 552.20 | 19.16 | 13.67 | 267.00 |
October | 356.83 | 0.51 | 0.48 | 01-OCT-06:40 | 1368.31 | 18.10 | 15.00 | 320.83 | 692.45 | 20.18 | 89.33 | 276.67 |
November | 337.67 | 0.50 | 0.48 | 01-NOV-07:10 | 1733.77 | 22.80 | 114.33 | 309.17 | 843.48 | 21.21 | 151.83 | 275.50 |
December | 349.33 | 0.51 | 0.48 | 01-DEC-06:40 | 2013.39 | 24.50 | 148.17 | 317.00 | 980.64 | 24.41 | 234.67 | 300.50 |
Annual Sum or Average | 4292.33 | 0.51 | 1255.40 | 18.59 | 424.50 | 3791.50 | 654.70 | 20.43 | 922.50 | 3333.33 | ||
Minimum of Months | 321.17 | 0.50 | 0.48 | 786.68 | 15.66 | 0.00 | 292.00 | 425.85 | 18.27 | 0.00 | 261.17 | |
Maximum of Months | 383.17 | 0.52 | 0.48 | 2013.39 | 24.50 | 148.17 | 323.83 | 980.64 | 24.47 | 235.83 | 307.17 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_2_DAYLCTRL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 350.67 | 0.52 | 0.48 | 01-JAN-07:19 | 1654.23 | 18.92 | 87.83 | 300.33 | 883.00 | 22.00 | 77.50 | 263.17 |
February | 321.17 | 0.52 | 0.48 | 01-FEB-06:40 | 1832.16 | 18.85 | 79.33 | 280.50 | 983.86 | 22.12 | 71.17 | 250.33 |
March | 361.17 | 0.51 | 0.48 | 01-MAR-07:10 | 2134.81 | 20.74 | 111.33 | 317.50 | 871.03 | 20.72 | 52.17 | 283.33 |
April | 358.33 | 0.50 | 0.48 | 01-APR-06:10 | 1743.40 | 18.97 | 84.00 | 321.83 | 908.42 | 20.68 | 54.17 | 285.17 |
May | 376.33 | 0.51 | 0.48 | 01-MAY-05:00 | 1496.56 | 18.20 | 87.00 | 330.33 | 768.88 | 19.92 | 56.67 | 285.50 |
June | 370.50 | 0.51 | 0.48 | 01-JUN-06:49 | 1604.11 | 18.61 | 84.00 | 327.33 | 829.69 | 20.36 | 54.50 | 287.83 |
July | 383.17 | 0.52 | 0.48 | 01-JUL-06:19 | 1335.68 | 17.88 | 86.50 | 329.67 | 676.73 | 19.57 | 56.17 | 278.00 |
August | 369.33 | 0.51 | 0.48 | 01-AUG-05:00 | 1520.99 | 18.56 | 86.00 | 329.50 | 783.45 | 20.23 | 55.00 | 285.50 |
September | 357.83 | 0.52 | 0.48 | 01-SEP-06:10 | 1436.97 | 18.00 | 83.50 | 308.00 | 731.21 | 19.59 | 54.50 | 263.50 |
October | 356.83 | 0.51 | 0.48 | 01-OCT-05:00 | 1435.75 | 18.54 | 86.17 | 309.50 | 728.64 | 20.11 | 55.17 | 265.33 |
November | 337.67 | 0.52 | 0.48 | 01-NOV-06:40 | 1448.50 | 19.19 | 84.33 | 291.17 | 723.15 | 20.48 | 51.33 | 249.17 |
December | 349.33 | 0.52 | 0.48 | 01-DEC-06:40 | 1634.93 | 20.41 | 108.17 | 294.83 | 746.28 | 20.86 | 55.83 | 256.17 |
Annual Sum or Average | 4292.33 | 0.51 | 1603.35 | 18.89 | 1068.17 | 3740.50 | 800.89 | 20.53 | 694.17 | 3253.00 | ||
Minimum of Months | 321.17 | 0.50 | 0.48 | 1335.68 | 17.88 | 79.33 | 280.50 | 676.73 | 19.57 | 51.33 | 249.17 | |
Maximum of Months | 383.17 | 0.52 | 0.48 | 2134.81 | 20.74 | 111.33 | 330.33 | 983.86 | 22.12 | 77.50 | 287.83 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_3_DAYLCTRL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 350.67 | 0.53 | 0.48 | 01-JAN-08:39 | 657.81 | 15.19 | 0.00 | 290.50 | 388.91 | 17.93 | 0.00 | 222.17 |
February | 321.17 | 0.53 | 0.48 | 01-FEB-07:49 | 723.81 | 15.73 | 0.00 | 276.17 | 429.56 | 18.45 | 0.00 | 226.83 |
March | 361.17 | 0.51 | 0.48 | 01-MAR-08:09 | 826.43 | 16.71 | 0.00 | 319.00 | 489.96 | 19.40 | 0.00 | 279.17 |
April | 358.33 | 0.50 | 0.48 | 01-APR-06:49 | 1014.41 | 17.76 | 0.00 | 328.00 | 574.57 | 20.43 | 4.17 | 294.17 |
May | 376.33 | 0.50 | 0.48 | 01-MAY-06:19 | 1187.12 | 17.61 | 3.83 | 344.83 | 620.71 | 20.22 | 85.67 | 310.17 |
June | 370.50 | 0.50 | 0.48 | 01-JUN-07:19 | 1423.77 | 22.26 | 111.33 | 345.33 | 722.54 | 22.16 | 162.00 | 316.17 |
July | 383.17 | 0.50 | 0.48 | 01-JUL-06:40 | 1228.53 | 20.50 | 93.00 | 343.67 | 615.81 | 22.35 | 97.33 | 311.33 |
August | 369.33 | 0.50 | 0.48 | 01-AUG-06:19 | 1099.89 | 17.50 | 0.00 | 337.50 | 588.18 | 20.14 | 55.83 | 298.17 |
September | 357.83 | 0.52 | 0.48 | 01-SEP-06:00 | 892.43 | 16.25 | 0.00 | 308.67 | 481.46 | 18.82 | 0.00 | 264.83 |
October | 356.83 | 0.52 | 0.48 | 01-OCT-07:40 | 788.18 | 15.97 | 0.00 | 303.50 | 431.68 | 18.57 | 0.00 | 247.67 |
November | 337.67 | 0.52 | 0.48 | 01-NOV-07:49 | 703.84 | 15.57 | 0.00 | 282.17 | 395.92 | 18.21 | 0.00 | 218.00 |
December | 349.33 | 0.54 | 0.48 | 01-DEC-07:40 | 641.35 | 14.96 | 0.00 | 283.33 | 374.32 | 17.68 | 0.00 | 214.17 |
Annual Sum or Average | 4292.33 | 0.51 | 940.89 | 17.23 | 208.17 | 3762.67 | 513.11 | 19.58 | 405.00 | 3202.83 | ||
Minimum of Months | 321.17 | 0.50 | 0.48 | 641.35 | 14.96 | 0.00 | 276.17 | 374.32 | 17.68 | 0.00 | 214.17 | |
Maximum of Months | 383.17 | 0.54 | 0.48 | 1423.77 | 22.26 | 111.33 | 345.33 | 722.54 | 22.35 | 162.00 | 316.17 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_4_DAYLCTRL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 350.67 | 0.52 | 0.48 | 01-JAN-08:00 | 1700.52 | 18.89 | 88.17 | 300.50 | 910.67 | 22.08 | 77.33 | 264.33 |
February | 321.17 | 0.52 | 0.48 | 01-FEB-08:09 | 1962.43 | 20.76 | 102.33 | 277.50 | 812.06 | 20.51 | 46.67 | 246.17 |
March | 361.17 | 0.51 | 0.48 | 01-MAR-08:30 | 2179.30 | 20.56 | 112.67 | 323.67 | 887.27 | 20.40 | 50.67 | 286.33 |
April | 358.33 | 0.50 | 0.48 | 01-APR-07:30 | 2121.54 | 14.03 | 0.00 | 321.00 | 876.97 | 17.95 | 0.00 | 284.83 |
May | 376.33 | 0.51 | 0.48 | 01-MAY-07:19 | 1665.37 | 13.77 | 0.00 | 330.50 | 738.96 | 17.45 | 0.00 | 284.00 |
June | 370.50 | 0.51 | 0.48 | 01-JUN-08:20 | 1558.47 | 14.21 | 0.00 | 326.50 | 811.59 | 18.02 | 0.00 | 287.00 |
July | 383.17 | 0.52 | 0.48 | 01-JUL-07:00 | 1336.03 | 13.57 | 0.00 | 329.50 | 676.79 | 17.15 | 0.00 | 279.50 |
August | 369.33 | 0.51 | 0.48 | 01-AUG-07:30 | 1529.63 | 14.39 | 8.50 | 328.17 | 767.40 | 17.64 | 0.00 | 283.17 |
September | 357.83 | 0.52 | 0.48 | 01-SEP-07:40 | 1581.96 | 17.58 | 85.00 | 305.33 | 710.82 | 17.40 | 7.67 | 263.67 |
October | 356.83 | 0.51 | 0.48 | 01-OCT-08:20 | 1486.52 | 18.38 | 87.17 | 307.83 | 769.00 | 21.18 | 70.83 | 265.17 |
November | 337.67 | 0.51 | 0.48 | 01-NOV-08:09 | 1482.02 | 18.94 | 85.00 | 293.83 | 753.54 | 20.59 | 56.67 | 250.17 |
December | 349.33 | 0.52 | 0.48 | 01-DEC-07:49 | 1535.89 | 18.83 | 87.33 | 298.67 | 813.27 | 21.54 | 71.83 | 259.17 |
Annual Sum or Average | 4292.33 | 0.51 | 1674.70 | 16.90 | 656.17 | 3743.00 | 792.97 | 19.27 | 381.67 | 3253.50 | ||
Minimum of Months | 321.17 | 0.50 | 0.48 | 1336.03 | 13.57 | 0.00 | 277.50 | 676.79 | 17.15 | 0.00 | 246.17 | |
Maximum of Months | 383.17 | 0.52 | 0.48 | 2179.30 | 20.76 | 112.67 | 330.50 | 910.67 | 22.08 | 77.33 | 287.00 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_1_DAYLCTRL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 350.67 | 0.51 | 0.48 | 01-JAN-07:49 | 1912.21 | 22.11 | 146.67 | 320.83 | 919.97 | 22.28 | 88.50 | 305.67 |
February | 321.17 | 0.51 | 0.48 | 01-FEB-07:10 | 1492.53 | 14.19 | 0.00 | 291.33 | 775.96 | 18.21 | 0.00 | 264.67 |
March | 361.17 | 0.51 | 0.48 | 01-MAR-07:49 | 1125.42 | 14.34 | 0.00 | 320.33 | 624.26 | 18.23 | 0.00 | 289.00 |
April | 358.33 | 0.51 | 0.48 | 01-APR-07:19 | 923.23 | 13.98 | 0.00 | 315.17 | 524.91 | 17.89 | 0.00 | 272.67 |
May | 376.33 | 0.52 | 0.48 | 01-MAY-07:10 | 793.60 | 12.54 | 0.00 | 319.67 | 440.82 | 16.39 | 0.00 | 263.50 |
June | 370.50 | 0.52 | 0.48 | 01-JUN-07:49 | 771.67 | 12.84 | 0.00 | 312.83 | 444.57 | 16.77 | 0.00 | 257.67 |
July | 383.17 | 0.53 | 0.48 | 01-JUL-07:30 | 753.91 | 11.91 | 0.00 | 317.83 | 407.58 | 15.75 | 0.00 | 253.67 |
August | 369.33 | 0.51 | 0.48 | 01-AUG-07:10 | 888.37 | 13.14 | 0.00 | 320.33 | 484.63 | 16.97 | 0.00 | 269.17 |
September | 357.83 | 0.52 | 0.48 | 01-SEP-06:00 | 1006.81 | 12.95 | 0.00 | 305.83 | 525.64 | 16.70 | 0.00 | 263.17 |
October | 356.83 | 0.51 | 0.48 | 01-OCT-06:00 | 1305.26 | 14.44 | 14.83 | 318.50 | 655.69 | 17.77 | 4.50 | 273.33 |
November | 337.67 | 0.50 | 0.48 | 01-NOV-07:10 | 1652.53 | 20.20 | 113.83 | 307.50 | 798.79 | 19.91 | 39.83 | 276.50 |
December | 349.33 | 0.51 | 0.48 | 01-DEC-06:40 | 1920.08 | 22.18 | 148.00 | 316.17 | 919.87 | 22.17 | 87.50 | 299.00 |
Annual Sum or Average | 4292.33 | 0.51 | 1198.30 | 15.32 | 423.33 | 3766.33 | 620.70 | 18.20 | 220.33 | 3288.00 | ||
Minimum of Months | 321.17 | 0.50 | 0.48 | 753.91 | 11.91 | 0.00 | 291.33 | 407.58 | 15.75 | 0.00 | 253.67 | |
Maximum of Months | 383.17 | 0.53 | 0.48 | 1920.08 | 22.18 | 148.00 | 320.83 | 919.97 | 22.28 | 88.50 | 305.67 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_2_DAYLCTRL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 350.67 | 0.52 | 0.48 | 01-JAN-07:19 | 1598.06 | 18.48 | 87.83 | 297.83 | 845.47 | 21.79 | 77.50 | 258.67 |
February | 321.17 | 0.52 | 0.48 | 01-FEB-06:40 | 1777.49 | 18.43 | 79.33 | 279.00 | 942.06 | 21.93 | 71.17 | 246.50 |
March | 361.17 | 0.51 | 0.48 | 01-MAR-07:10 | 2006.06 | 18.27 | 87.83 | 313.17 | 827.23 | 20.54 | 52.17 | 280.83 |
April | 358.33 | 0.50 | 0.48 | 01-APR-06:19 | 1673.50 | 18.57 | 84.00 | 319.00 | 864.05 | 20.51 | 54.17 | 281.67 |
May | 376.33 | 0.51 | 0.48 | 01-MAY-05:00 | 1455.26 | 17.80 | 87.00 | 327.83 | 732.22 | 19.75 | 56.83 | 279.00 |
June | 370.50 | 0.51 | 0.48 | 01-JUN-06:49 | 1551.55 | 18.21 | 84.00 | 323.67 | 790.58 | 20.21 | 54.50 | 283.17 |
July | 383.17 | 0.52 | 0.48 | 01-JUL-06:30 | 1293.72 | 17.49 | 86.50 | 325.83 | 644.72 | 19.42 | 56.33 | 272.33 |
August | 369.33 | 0.51 | 0.48 | 01-AUG-05:00 | 1471.23 | 18.17 | 86.00 | 325.50 | 745.50 | 20.06 | 55.00 | 281.00 |
September | 357.83 | 0.52 | 0.48 | 01-SEP-06:10 | 1377.53 | 17.60 | 83.50 | 306.17 | 695.77 | 19.41 | 54.50 | 258.17 |
October | 356.83 | 0.52 | 0.48 | 01-OCT-06:10 | 1391.02 | 18.12 | 86.17 | 307.00 | 693.94 | 19.90 | 55.17 | 260.17 |
November | 337.67 | 0.52 | 0.48 | 01-NOV-06:40 | 1391.99 | 18.52 | 81.33 | 289.00 | 688.89 | 20.26 | 51.33 | 244.17 |
December | 349.33 | 0.53 | 0.48 | 01-DEC-06:40 | 1544.54 | 18.18 | 87.83 | 290.67 | 711.16 | 20.63 | 56.00 | 251.83 |
Annual Sum or Average | 4292.33 | 0.52 | 1541.34 | 18.14 | 1021.33 | 3704.67 | 763.20 | 20.34 | 694.67 | 3197.50 | ||
Minimum of Months | 321.17 | 0.50 | 0.48 | 1293.72 | 17.49 | 79.33 | 279.00 | 644.72 | 19.41 | 51.33 | 244.17 | |
Maximum of Months | 383.17 | 0.53 | 0.48 | 2006.06 | 18.57 | 87.83 | 327.83 | 942.06 | 21.93 | 77.50 | 283.17 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_3_DAYLCTRL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 350.67 | 0.54 | 0.48 | 01-JAN-08:50 | 629.50 | 11.83 | 0.00 | 286.50 | 373.72 | 15.76 | 0.00 | 213.83 |
February | 321.17 | 0.53 | 0.48 | 01-FEB-07:00 | 692.79 | 12.47 | 0.00 | 274.00 | 412.88 | 16.38 | 0.00 | 221.17 |
March | 361.17 | 0.52 | 0.48 | 01-MAR-08:09 | 790.53 | 13.53 | 0.00 | 317.00 | 470.55 | 17.43 | 0.00 | 274.83 |
April | 358.33 | 0.50 | 0.48 | 01-APR-06:49 | 969.49 | 14.44 | 0.00 | 326.17 | 549.58 | 18.40 | 0.00 | 289.17 |
May | 376.33 | 0.50 | 0.48 | 01-MAY-06:19 | 1134.32 | 13.88 | 3.83 | 342.17 | 589.83 | 17.68 | 1.17 | 307.00 |
June | 370.50 | 0.50 | 0.48 | 01-JUN-07:30 | 1360.18 | 19.70 | 110.83 | 342.83 | 684.28 | 19.85 | 33.17 | 313.83 |
July | 383.17 | 0.51 | 0.48 | 01-JUL-06:49 | 1174.93 | 17.63 | 92.83 | 342.50 | 584.18 | 20.04 | 59.17 | 305.83 |
August | 369.33 | 0.50 | 0.48 | 01-AUG-06:19 | 1049.11 | 13.88 | 0.00 | 333.50 | 560.32 | 17.77 | 0.00 | 295.50 |
September | 357.83 | 0.52 | 0.48 | 01-SEP-06:00 | 854.22 | 12.67 | 0.00 | 307.00 | 460.12 | 16.43 | 0.00 | 259.67 |
October | 356.83 | 0.52 | 0.48 | 01-OCT-07:49 | 755.00 | 12.33 | 0.00 | 301.17 | 413.37 | 16.16 | 0.00 | 240.50 |
November | 337.67 | 0.53 | 0.48 | 01-NOV-07:49 | 674.20 | 11.98 | 0.00 | 278.83 | 379.77 | 15.86 | 0.00 | 209.33 |
December | 349.33 | 0.54 | 0.48 | 01-DEC-07:40 | 613.81 | 11.52 | 0.00 | 279.33 | 359.51 | 15.42 | 0.00 | 206.50 |
Annual Sum or Average | 4292.33 | 0.52 | 899.70 | 13.89 | 207.50 | 3731.00 | 489.89 | 17.31 | 93.50 | 3137.17 | ||
Minimum of Months | 321.17 | 0.50 | 0.48 | 613.81 | 11.52 | 0.00 | 274.00 | 359.51 | 15.42 | 0.00 | 206.50 | |
Maximum of Months | 383.17 | 0.54 | 0.48 | 1360.18 | 19.70 | 110.83 | 342.83 | 684.28 | 20.04 | 59.17 | 313.83 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_4_DAYLCTRL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 350.67 | 0.52 | 0.48 | 01-JAN-09:20 | 1644.74 | 18.51 | 88.17 | 297.50 | 872.80 | 21.96 | 77.50 | 259.33 |
February | 321.17 | 0.52 | 0.48 | 01-FEB-08:20 | 1906.06 | 20.41 | 102.33 | 275.83 | 771.55 | 20.38 | 46.67 | 242.33 |
March | 361.17 | 0.51 | 0.48 | 01-MAR-08:39 | 2122.75 | 20.21 | 112.67 | 321.17 | 843.29 | 20.25 | 50.83 | 281.83 |
April | 358.33 | 0.51 | 0.48 | 01-APR-07:40 | 2044.27 | 13.53 | 0.00 | 318.67 | 833.55 | 17.75 | 0.00 | 280.67 |
May | 376.33 | 0.51 | 0.48 | 01-MAY-07:30 | 1624.28 | 13.27 | 0.00 | 328.50 | 702.83 | 17.21 | 0.00 | 278.83 |
June | 370.50 | 0.51 | 0.48 | 01-JUN-08:20 | 1510.04 | 13.70 | 0.00 | 324.67 | 772.55 | 17.78 | 0.00 | 283.17 |
July | 383.17 | 0.52 | 0.48 | 01-JUL-07:00 | 1295.24 | 13.05 | 0.00 | 326.67 | 644.47 | 16.90 | 0.00 | 274.17 |
August | 369.33 | 0.51 | 0.48 | 01-AUG-07:40 | 1472.43 | 13.90 | 8.50 | 325.50 | 730.21 | 17.42 | 0.00 | 279.00 |
September | 357.83 | 0.52 | 0.48 | 01-SEP-07:40 | 1494.42 | 17.17 | 85.00 | 304.00 | 675.74 | 17.20 | 7.67 | 258.67 |
October | 356.83 | 0.52 | 0.48 | 01-OCT-08:20 | 1442.25 | 17.99 | 87.17 | 306.83 | 734.27 | 21.04 | 70.83 | 260.17 |
November | 337.67 | 0.51 | 0.48 | 01-NOV-08:20 | 1429.09 | 18.56 | 85.00 | 291.33 | 717.63 | 20.31 | 55.00 | 245.83 |
December | 349.33 | 0.52 | 0.48 | 01-DEC-07:00 | 1483.24 | 18.46 | 87.17 | 296.83 | 759.31 | 20.38 | 59.17 | 253.67 |
Annual Sum or Average | 4292.33 | 0.52 | 1618.95 | 16.47 | 656.00 | 3717.50 | 753.87 | 18.99 | 367.67 | 3197.67 | ||
Minimum of Months | 321.17 | 0.51 | 0.48 | 1295.24 | 13.05 | 0.00 | 275.83 | 644.47 | 16.90 | 0.00 | 242.33 | |
Maximum of Months | 383.17 | 0.52 | 0.48 | 2122.75 | 20.41 | 112.67 | 328.50 | 872.80 | 21.96 | 77.50 | 283.17 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_1_DAYLCTRL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 350.67 | 0.51 | 0.48 | 01-JAN-07:49 | 1912.13 | 22.11 | 146.67 | 320.83 | 919.90 | 22.28 | 88.50 | 305.67 |
February | 321.17 | 0.51 | 0.48 | 01-FEB-07:10 | 1492.46 | 14.19 | 0.00 | 291.33 | 775.90 | 18.21 | 0.00 | 264.67 |
March | 361.17 | 0.51 | 0.48 | 01-MAR-07:49 | 1125.37 | 14.34 | 0.00 | 320.33 | 624.22 | 18.23 | 0.00 | 289.00 |
April | 358.33 | 0.51 | 0.48 | 01-APR-07:19 | 923.20 | 13.98 | 0.00 | 315.17 | 524.88 | 17.89 | 0.00 | 272.67 |
May | 376.33 | 0.52 | 0.48 | 01-MAY-07:10 | 793.57 | 12.54 | 0.00 | 319.67 | 440.79 | 16.39 | 0.00 | 263.50 |
June | 370.50 | 0.52 | 0.48 | 01-JUN-07:49 | 771.65 | 12.84 | 0.00 | 312.83 | 444.54 | 16.77 | 0.00 | 257.67 |
July | 383.17 | 0.53 | 0.48 | 01-JUL-07:30 | 753.87 | 11.91 | 0.00 | 317.83 | 407.55 | 15.75 | 0.00 | 253.67 |
August | 369.33 | 0.51 | 0.48 | 01-AUG-07:10 | 888.33 | 13.14 | 0.00 | 320.33 | 484.59 | 16.97 | 0.00 | 269.17 |
September | 357.83 | 0.52 | 0.48 | 01-SEP-06:00 | 1006.76 | 12.95 | 0.00 | 305.83 | 525.60 | 16.70 | 0.00 | 263.17 |
October | 356.83 | 0.51 | 0.48 | 01-OCT-06:00 | 1305.19 | 14.45 | 14.83 | 318.50 | 655.63 | 17.77 | 4.50 | 273.33 |
November | 337.67 | 0.50 | 0.48 | 01-NOV-07:10 | 1652.45 | 20.20 | 113.83 | 307.50 | 798.72 | 19.92 | 39.83 | 276.50 |
December | 349.33 | 0.51 | 0.48 | 01-DEC-06:40 | 1920.00 | 22.18 | 148.00 | 316.17 | 919.80 | 22.17 | 87.50 | 299.00 |
Annual Sum or Average | 4292.33 | 0.51 | 1198.25 | 15.32 | 423.33 | 3766.33 | 620.66 | 18.20 | 220.33 | 3288.00 | ||
Minimum of Months | 321.17 | 0.50 | 0.48 | 753.87 | 11.91 | 0.00 | 291.33 | 407.55 | 15.75 | 0.00 | 253.67 | |
Maximum of Months | 383.17 | 0.53 | 0.48 | 1920.00 | 22.18 | 148.00 | 320.83 | 919.90 | 22.28 | 88.50 | 305.67 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_2_DAYLCTRL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 350.67 | 0.52 | 0.48 | 01-JAN-07:19 | 1598.03 | 18.48 | 87.83 | 297.83 | 845.42 | 21.80 | 77.50 | 258.67 |
February | 321.17 | 0.52 | 0.48 | 01-FEB-06:40 | 1777.46 | 18.43 | 79.33 | 279.00 | 942.01 | 21.93 | 71.17 | 246.50 |
March | 361.17 | 0.51 | 0.48 | 01-MAR-07:10 | 2006.04 | 18.27 | 87.83 | 313.17 | 827.18 | 20.54 | 52.17 | 280.83 |
April | 358.33 | 0.50 | 0.48 | 01-APR-06:19 | 1673.47 | 18.57 | 84.00 | 319.00 | 864.00 | 20.51 | 54.17 | 281.67 |
May | 376.33 | 0.51 | 0.48 | 01-MAY-05:00 | 1455.22 | 17.80 | 87.00 | 327.83 | 732.18 | 19.75 | 56.83 | 279.00 |
June | 370.50 | 0.51 | 0.48 | 01-JUN-06:49 | 1551.51 | 18.21 | 84.00 | 323.67 | 790.53 | 20.21 | 54.50 | 283.17 |
July | 383.17 | 0.52 | 0.48 | 01-JUL-06:30 | 1293.67 | 17.49 | 86.50 | 325.83 | 644.67 | 19.42 | 56.33 | 272.33 |
August | 369.33 | 0.51 | 0.48 | 01-AUG-05:00 | 1471.19 | 18.17 | 86.00 | 325.50 | 745.45 | 20.06 | 55.00 | 281.00 |
September | 357.83 | 0.52 | 0.48 | 01-SEP-06:10 | 1377.48 | 17.61 | 83.50 | 306.17 | 695.72 | 19.41 | 54.50 | 258.17 |
October | 356.83 | 0.52 | 0.48 | 01-OCT-06:10 | 1390.98 | 18.12 | 86.17 | 307.00 | 693.89 | 19.90 | 55.17 | 260.17 |
November | 337.67 | 0.52 | 0.48 | 01-NOV-06:40 | 1391.95 | 18.52 | 81.33 | 289.00 | 688.83 | 20.26 | 51.33 | 244.17 |
December | 349.33 | 0.53 | 0.48 | 01-DEC-06:40 | 1544.52 | 18.18 | 87.83 | 290.67 | 711.11 | 20.64 | 56.00 | 251.83 |
Annual Sum or Average | 4292.33 | 0.52 | 1541.30 | 18.14 | 1021.33 | 3704.67 | 763.15 | 20.34 | 694.67 | 3197.50 | ||
Minimum of Months | 321.17 | 0.50 | 0.48 | 1293.67 | 17.49 | 79.33 | 279.00 | 644.67 | 19.41 | 51.33 | 244.17 | |
Maximum of Months | 383.17 | 0.53 | 0.48 | 2006.04 | 18.57 | 87.83 | 327.83 | 942.01 | 21.93 | 77.50 | 283.17 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_3_DAYLCTRL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 350.67 | 0.54 | 0.48 | 01-JAN-08:50 | 629.49 | 11.83 | 0.00 | 286.50 | 373.70 | 15.76 | 0.00 | 213.83 |
February | 321.17 | 0.53 | 0.48 | 01-FEB-07:00 | 692.78 | 12.47 | 0.00 | 274.00 | 412.86 | 16.38 | 0.00 | 221.17 |
March | 361.17 | 0.52 | 0.48 | 01-MAR-08:09 | 790.52 | 13.53 | 0.00 | 317.00 | 470.52 | 17.43 | 0.00 | 274.83 |
April | 358.33 | 0.50 | 0.48 | 01-APR-06:49 | 969.46 | 14.44 | 0.00 | 326.17 | 549.54 | 18.40 | 0.00 | 289.17 |
May | 376.33 | 0.50 | 0.48 | 01-MAY-06:19 | 1134.27 | 13.88 | 3.83 | 342.17 | 589.79 | 17.68 | 1.17 | 307.00 |
June | 370.50 | 0.50 | 0.48 | 01-JUN-07:30 | 1360.12 | 19.70 | 111.00 | 342.83 | 684.23 | 19.85 | 33.17 | 313.83 |
July | 383.17 | 0.51 | 0.48 | 01-JUL-06:49 | 1174.86 | 17.63 | 92.83 | 342.50 | 584.13 | 20.04 | 59.17 | 305.83 |
August | 369.33 | 0.50 | 0.48 | 01-AUG-06:19 | 1049.06 | 13.88 | 0.00 | 333.50 | 560.27 | 17.77 | 0.00 | 295.50 |
September | 357.83 | 0.52 | 0.48 | 01-SEP-06:00 | 854.18 | 12.67 | 0.00 | 307.00 | 460.09 | 16.43 | 0.00 | 259.67 |
October | 356.83 | 0.52 | 0.48 | 01-OCT-07:49 | 754.97 | 12.33 | 0.00 | 301.17 | 413.34 | 16.16 | 0.00 | 240.50 |
November | 337.67 | 0.53 | 0.48 | 01-NOV-07:49 | 674.17 | 11.98 | 0.00 | 278.83 | 379.75 | 15.86 | 0.00 | 209.33 |
December | 349.33 | 0.54 | 0.48 | 01-DEC-07:40 | 613.80 | 11.52 | 0.00 | 279.33 | 359.48 | 15.42 | 0.00 | 206.50 |
Annual Sum or Average | 4292.33 | 0.52 | 899.67 | 13.89 | 207.67 | 3731.00 | 489.86 | 17.31 | 93.50 | 3137.17 | ||
Minimum of Months | 321.17 | 0.50 | 0.48 | 613.80 | 11.52 | 0.00 | 274.00 | 359.48 | 15.42 | 0.00 | 206.50 | |
Maximum of Months | 383.17 | 0.54 | 0.48 | 1360.12 | 19.70 | 111.00 | 342.83 | 684.23 | 20.04 | 59.17 | 313.83 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_4_DAYLCTRL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 350.67 | 0.52 | 0.48 | 01-JAN-09:20 | 1644.71 | 18.51 | 88.17 | 297.50 | 872.76 | 21.96 | 77.50 | 259.33 |
February | 321.17 | 0.52 | 0.48 | 01-FEB-08:20 | 1906.03 | 20.41 | 102.33 | 275.83 | 771.50 | 20.38 | 46.67 | 242.33 |
March | 361.17 | 0.51 | 0.48 | 01-MAR-08:39 | 2122.72 | 20.21 | 112.67 | 321.17 | 843.24 | 20.25 | 50.83 | 281.83 |
April | 358.33 | 0.51 | 0.48 | 01-APR-07:40 | 2044.24 | 13.53 | 0.00 | 318.67 | 833.50 | 17.75 | 0.00 | 280.67 |
May | 376.33 | 0.51 | 0.48 | 01-MAY-07:30 | 1624.23 | 13.27 | 0.00 | 328.33 | 702.78 | 17.21 | 0.00 | 278.83 |
June | 370.50 | 0.51 | 0.48 | 01-JUN-08:20 | 1510.01 | 13.70 | 0.00 | 324.67 | 772.50 | 17.78 | 0.00 | 283.17 |
July | 383.17 | 0.52 | 0.48 | 01-JUL-07:00 | 1295.18 | 13.05 | 0.00 | 326.67 | 644.42 | 16.90 | 0.00 | 274.17 |
August | 369.33 | 0.51 | 0.48 | 01-AUG-07:40 | 1472.39 | 13.90 | 8.50 | 325.33 | 730.16 | 17.42 | 0.00 | 279.00 |
September | 357.83 | 0.52 | 0.48 | 01-SEP-07:40 | 1494.37 | 17.17 | 85.00 | 304.00 | 675.69 | 17.20 | 7.67 | 258.67 |
October | 356.83 | 0.52 | 0.48 | 01-OCT-08:20 | 1442.20 | 17.99 | 87.17 | 306.83 | 734.21 | 21.04 | 70.83 | 260.17 |
November | 337.67 | 0.51 | 0.48 | 01-NOV-08:20 | 1429.05 | 18.56 | 85.00 | 291.33 | 717.58 | 20.31 | 55.00 | 245.83 |
December | 349.33 | 0.52 | 0.48 | 01-DEC-07:00 | 1483.22 | 18.46 | 87.17 | 296.83 | 759.26 | 20.38 | 59.17 | 253.67 |
Annual Sum or Average | 4292.33 | 0.52 | 1618.91 | 16.47 | 656.00 | 3717.17 | 753.82 | 19.00 | 367.67 | 3197.67 | ||
Minimum of Months | 321.17 | 0.51 | 0.48 | 1295.18 | 13.05 | 0.00 | 275.83 | 644.42 | 16.90 | 0.00 | 242.33 | |
Maximum of Months | 383.17 | 0.52 | 0.48 | 2122.72 | 20.41 | 112.67 | 328.33 | 872.76 | 21.96 | 77.50 | 283.17 |
Report: CoilReportMonthly
For: CORE_BOTTOM VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CORE_MID VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CORE_TOP VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_BOT HEATING COIL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_MID HEATING COIL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_TOP HEATING COIL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_BOT COOLING COIL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.960654E+11 | 0.647008E+11 | 108606.96 | 09-JAN-05:02 | 76414.21 | 0.00 |
February | 0.00 | 0.00 | 0.904219E+11 | 0.610041E+11 | 105196.27 | 06-FEB-05:02 | 75906.11 | 0.00 |
March | 0.00 | 0.00 | 0.109718E+12 | 0.722640E+11 | 112254.34 | 28-MAR-04:03 | 76672.68 | 0.00 |
April | 0.00 | 0.00 | 0.114202E+12 | 0.686568E+11 | 113000.80 | 29-APR-05:03 | 76935.67 | 0.00 |
May | 0.00 | 0.00 | 0.131386E+12 | 0.734080E+11 | 126692.82 | 22-MAY-04:02 | 77063.67 | 0.00 |
June | 0.00 | 0.00 | 0.132325E+12 | 0.743917E+11 | 123164.65 | 13-JUN-04:02 | 78896.44 | 0.00 |
July | 0.00 | 0.00 | 0.105765E+12 | 0.642401E+11 | 108954.20 | 24-JUL-04:02 | 78942.77 | 0.00 |
August | 0.00 | 0.00 | 0.124426E+12 | 0.682793E+11 | 126753.96 | 21-AUG-04:02 | 75239.51 | 0.00 |
September | 0.00 | 0.00 | 0.113150E+12 | 0.631435E+11 | 114648.96 | 25-SEP-04:02 | 77912.53 | 0.00 |
October | 0.00 | 0.00 | 0.109448E+12 | 0.617814E+11 | 115437.24 | 30-OCT-04:02 | 77592.99 | 0.00 |
November | 0.00 | 0.00 | 0.102340E+12 | 0.615845E+11 | 113664.31 | 13-NOV-07:03 | 79200.31 | 0.00 |
December | 0.00 | 0.00 | 0.942465E+11 | 0.607538E+11 | 103849.71 | 11-DEC-05:02 | 73460.89 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.132349E+13 | 0.794208E+12 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.904219E+11 | 0.607538E+11 | 103849.71 | 73460.89 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.132325E+12 | 0.743917E+11 | 126753.96 | 79200.31 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_MID COOLING COIL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.668333E+11 | 0.498429E+11 | 93860.64 | 09-JAN-05:02 | 63395.02 | 0.00 |
February | 0.00 | 0.00 | 0.626716E+11 | 0.470271E+11 | 89940.32 | 06-FEB-05:02 | 62598.77 | 0.00 |
March | 0.00 | 0.00 | 0.736525E+11 | 0.548840E+11 | 100398.95 | 27-MAR-04:02 | 66364.66 | 0.00 |
April | 0.00 | 0.00 | 0.730702E+11 | 0.518980E+11 | 96755.47 | 10-APR-04:02 | 64570.32 | 0.00 |
May | 0.00 | 0.00 | 0.823433E+11 | 0.551435E+11 | 105559.15 | 22-MAY-04:02 | 65220.64 | 0.00 |
June | 0.00 | 0.00 | 0.828892E+11 | 0.558433E+11 | 105393.76 | 12-JUN-04:02 | 66166.01 | 0.00 |
July | 0.00 | 0.00 | 0.706138E+11 | 0.485894E+11 | 96075.61 | 24-JUL-04:02 | 65854.32 | 0.00 |
August | 0.00 | 0.00 | 0.771222E+11 | 0.507493E+11 | 105995.12 | 21-AUG-05:03 | 56784.74 | 0.00 |
September | 0.00 | 0.00 | 0.713434E+11 | 0.473954E+11 | 103723.23 | 25-SEP-04:02 | 65317.24 | 0.00 |
October | 0.00 | 0.00 | 0.711869E+11 | 0.472775E+11 | 103596.91 | 30-OCT-04:02 | 64786.47 | 0.00 |
November | 0.00 | 0.00 | 0.675690E+11 | 0.470949E+11 | 100089.67 | 13-NOV-05:02 | 65568.42 | 0.00 |
December | 0.00 | 0.00 | 0.644455E+11 | 0.466362E+11 | 88210.83 | 11-DEC-05:02 | 58358.38 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.863741E+12 | 0.602381E+12 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.626716E+11 | 0.466362E+11 | 88210.83 | 56784.74 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.828892E+11 | 0.558433E+11 | 105995.12 | 66364.66 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_TOP COOLING COIL
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.873293E+11 | 0.587884E+11 | 104024.20 | 02-JAN-05:02 | 73415.66 | 0.00 |
February | 0.00 | 0.00 | 0.843344E+11 | 0.568905E+11 | 98729.72 | 26-FEB-15:52 | 71584.44 | 0.00 |
March | 0.00 | 0.00 | 0.103022E+12 | 0.681914E+11 | 117842.97 | 20-MAR-04:02 | 79812.94 | 0.00 |
April | 0.00 | 0.00 | 0.109308E+12 | 0.658796E+11 | 118616.50 | 02-APR-15:42 | 77176.71 | 0.00 |
May | 0.00 | 0.00 | 0.123226E+12 | 0.687555E+11 | 130084.09 | 22-MAY-04:02 | 73816.63 | 0.00 |
June | 0.00 | 0.00 | 0.124218E+12 | 0.697534E+11 | 126058.06 | 13-JUN-04:02 | 75275.90 | 0.00 |
July | 0.00 | 0.00 | 0.971975E+11 | 0.582700E+11 | 110109.58 | 10-JUL-04:02 | 76434.13 | 0.00 |
August | 0.00 | 0.00 | 0.112907E+12 | 0.609036E+11 | 130279.09 | 13-AUG-13:32 | 78740.44 | 0.00 |
September | 0.00 | 0.00 | 0.104208E+12 | 0.574937E+11 | 122976.75 | 04-SEP-13:23 | 75414.59 | 0.00 |
October | 0.00 | 0.00 | 0.997182E+11 | 0.553112E+11 | 114541.93 | 30-OCT-04:02 | 72765.57 | 0.00 |
November | 0.00 | 0.00 | 0.925426E+11 | 0.551503E+11 | 104750.29 | 13-NOV-05:02 | 68521.27 | 0.00 |
December | 0.00 | 0.00 | 0.856935E+11 | 0.548406E+11 | 89290.06 | 10-DEC-16:23 | 56305.80 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.122371E+13 | 0.730228E+12 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.843344E+11 | 0.548406E+11 | 89290.06 | 56305.80 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.124218E+12 | 0.697534E+11 | 130279.09 | 79812.94 | 0.00 |
Report: PlantLoopDemandReportMonthly
For: SWHSYS1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 1187.16 | 4021.56 | 05-JAN-12:08 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 1187.50 | 4011.11 | 02-FEB-12:08 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 1245.27 | 3968.16 | 01-MAR-12:17 |
April | 0.00 | 0.00 | 01-APR-00:10 | 1142.65 | 3893.43 | 04-APR-11:08 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 1160.35 | 3823.10 | 01-MAY-11:16 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 1173.22 | 3736.92 | 06-JUN-11:20 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 1074.26 | 3702.49 | 24-JUL-11:08 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 1183.90 | 3757.29 | 31-AUG-11:13 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 1124.87 | 3822.41 | 29-SEP-11:17 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 1146.90 | 3904.83 | 31-OCT-11:10 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 1185.64 | 3965.60 | 30-NOV-12:20 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 1153.86 | 4014.20 | 29-DEC-12:17 |
Annual Sum or Average | 0.00 | 1163.68 | ||||
Minimum of Months | 0.00 | 0.00 | 1074.26 | 3702.49 | ||
Maximum of Months | 0.00 | 0.00 | 1245.27 | 4021.56 |
Report: FanReportMonthly
For: PACU_VAV_BOT FAN
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.365997E+10 | 0.44 | 10031.36 | 09-JAN-05:02 | 1.78 |
February | 0.345382E+10 | 0.45 | 10031.36 | 06-FEB-05:02 | 1.78 |
March | 0.403057E+10 | 0.47 | 10031.36 | 13-MAR-04:02 | 1.78 |
April | 0.375469E+10 | 0.46 | 10031.36 | 03-APR-04:02 | 1.78 |
May | 0.408445E+10 | 0.48 | 10031.36 | 01-MAY-04:02 | 1.78 |
June | 0.433312E+10 | 0.50 | 10031.36 | 05-JUN-04:02 | 1.78 |
July | 0.362990E+10 | 0.44 | 10031.36 | 03-JUL-04:02 | 1.78 |
August | 0.384541E+10 | 0.46 | 10031.36 | 02-AUG-04:03 | 1.78 |
September | 0.346458E+10 | 0.44 | 10031.36 | 11-SEP-04:02 | 1.78 |
October | 0.343499E+10 | 0.42 | 10031.36 | 02-OCT-04:02 | 1.78 |
November | 0.350899E+10 | 0.44 | 10031.36 | 06-NOV-05:02 | 1.78 |
December | 0.334871E+10 | 0.42 | 10031.36 | 26-DEC-05:02 | 1.78 |
Annual Sum or Average | 0.445492E+11 | 0.45 | |||
Minimum of Months | 0.334871E+10 | 0.42 | 10031.36 | 1.78 | |
Maximum of Months | 0.433312E+10 | 0.50 | 10031.36 | 1.78 |
Report: FanReportMonthly
For: PACU_VAV_MID FAN
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.291862E+10 | 0.42 | 8399.20 | 02-JAN-05:02 | 1.78 |
February | 0.278751E+10 | 0.44 | 8399.20 | 21-FEB-07:03 | 1.78 |
March | 0.317842E+10 | 0.45 | 8399.20 | 13-MAR-04:02 | 1.78 |
April | 0.291156E+10 | 0.44 | 8399.20 | 01-APR-05:03 | 1.78 |
May | 0.314459E+10 | 0.45 | 8399.20 | 01-MAY-04:02 | 1.78 |
June | 0.331204E+10 | 0.47 | 8399.20 | 05-JUN-04:02 | 1.78 |
July | 0.270302E+10 | 0.41 | 8399.20 | 03-JUL-04:02 | 1.78 |
August | 0.281318E+10 | 0.42 | 8399.20 | 12-AUG-05:03 | 1.78 |
September | 0.258885E+10 | 0.41 | 8399.20 | 01-SEP-05:03 | 1.78 |
October | 0.260906E+10 | 0.40 | 8399.20 | 02-OCT-04:02 | 1.78 |
November | 0.270623E+10 | 0.41 | 8399.20 | 06-NOV-05:02 | 1.78 |
December | 0.263230E+10 | 0.40 | 8399.20 | 26-DEC-05:02 | 1.78 |
Annual Sum or Average | 0.343054E+11 | 0.43 | |||
Minimum of Months | 0.258885E+10 | 0.40 | 8399.20 | 1.78 | |
Maximum of Months | 0.331204E+10 | 0.47 | 8399.20 | 1.78 |
Report: FanReportMonthly
For: PACU_VAV_TOP FAN
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.284200E+10 | 0.38 | 9125.18 | 02-JAN-05:02 | 1.66 |
February | 0.277271E+10 | 0.40 | 8950.35 | 21-FEB-05:02 | 1.64 |
March | 0.325045E+10 | 0.42 | 10153.50 | 20-MAR-04:02 | 1.78 |
April | 0.303208E+10 | 0.41 | 10153.50 | 03-APR-04:02 | 1.78 |
May | 0.319314E+10 | 0.42 | 10153.50 | 08-MAY-04:02 | 1.78 |
June | 0.337173E+10 | 0.44 | 10153.50 | 12-JUN-04:02 | 1.78 |
July | 0.269025E+10 | 0.38 | 10153.50 | 31-JUL-04:02 | 1.78 |
August | 0.280181E+10 | 0.39 | 10153.50 | 14-AUG-04:02 | 1.78 |
September | 0.261244E+10 | 0.38 | 10153.50 | 05-SEP-04:02 | 1.78 |
October | 0.254052E+10 | 0.37 | 9639.17 | 16-OCT-04:02 | 1.72 |
November | 0.262770E+10 | 0.37 | 7903.65 | 20-NOV-05:02 | 1.52 |
December | 0.256616E+10 | 0.36 | 7033.86 | 26-DEC-05:02 | 1.41 |
Annual Sum or Average | 0.343010E+11 | 0.39 | |||
Minimum of Months | 0.254052E+10 | 0.36 | 7033.86 | 1.41 | |
Maximum of Months | 0.337173E+10 | 0.44 | 10153.50 | 1.78 |
Report: PumpReportMonthly
For: SWHSYS1 PUMP
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportPUMP ELECTRICITY ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRICITY RATE {Maximum} [W] | PUMP ELECTRICITY RATE {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
January | 1312252.65 | 393675.80 | 0.73 | 01-JAN-06:10 | 0.22 | 0.22 | 57.58 | 0.05 |
February | 1186778.30 | 356033.49 | 0.73 | 01-FEB-06:03 | 0.22 | 0.22 | 57.35 | 0.05 |
March | 1343621.24 | 403086.37 | 0.73 | 01-MAR-06:03 | 0.22 | 0.22 | 56.63 | 0.05 |
April | 1267813.82 | 380344.15 | 0.73 | 01-APR-05:03 | 0.22 | 0.22 | 56.56 | 0.05 |
May | 1327936.95 | 398381.08 | 0.73 | 01-MAY-05:03 | 0.22 | 0.22 | 57.39 | 0.05 |
June | 1296568.36 | 388970.51 | 0.73 | 01-JUN-05:03 | 0.22 | 0.22 | 57.32 | 0.05 |
July | 1299182.41 | 389754.72 | 0.73 | 01-JUL-05:03 | 0.22 | 0.22 | 57.37 | 0.05 |
August | 1343621.24 | 403086.37 | 0.73 | 01-AUG-05:03 | 0.22 | 0.22 | 57.15 | 0.05 |
September | 1267813.82 | 380344.15 | 0.73 | 01-SEP-05:03 | 0.22 | 0.22 | 57.48 | 0.05 |
October | 1312252.65 | 393675.80 | 0.73 | 01-OCT-05:10 | 0.22 | 0.22 | 57.83 | 0.05 |
November | 1278270.02 | 383481.00 | 0.73 | 01-NOV-05:03 | 0.22 | 0.22 | 57.25 | 0.05 |
December | 1299182.41 | 389754.72 | 0.73 | 01-DEC-06:03 | 0.22 | 0.22 | 56.75 | 0.05 |
Annual Sum or Average | 15535293.87 | 4660588.16 | ||||||
Minimum of Months | 1186778.30 | 356033.49 | 0.73 | 0.22 | 0.22 | 56.56 | 0.05 | |
Maximum of Months | 1343621.24 | 403086.37 | 0.73 | 0.22 | 0.22 | 57.83 | 0.05 |
Report: CondLoopDemandReportMonthly
For: SWHSYS1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:03 | 58.59 | 58.59 | 1187.16 | 4021.56 | 05-JAN-12:08 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 58.21 | 58.21 | 1187.50 | 4011.11 | 02-FEB-12:08 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 56.83 | 56.83 | 1245.27 | 3968.16 | 01-MAR-12:17 |
April | 0.00 | 0.00 | 01-APR-00:10 | 56.75 | 56.75 | 1142.65 | 3893.43 | 04-APR-11:08 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 57.55 | 57.55 | 1160.35 | 3823.10 | 01-MAY-11:16 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 57.50 | 57.50 | 1173.22 | 3736.92 | 06-JUN-11:20 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 57.55 | 57.55 | 1074.26 | 3702.49 | 24-JUL-11:08 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 57.32 | 57.32 | 1183.90 | 3757.29 | 31-AUG-11:13 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 58.30 | 58.30 | 1124.87 | 3822.41 | 29-SEP-11:17 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 56.43 | 56.43 | 1146.90 | 3904.83 | 31-OCT-11:10 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 57.98 | 57.98 | 1185.64 | 3965.60 | 30-NOV-12:20 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 56.96 | 56.96 | 1153.86 | 4014.20 | 29-DEC-12:17 |
Annual Sum or Average | 0.00 | 1163.68 | ||||||
Minimum of Months | 0.00 | 0.00 | 56.43 | 56.43 | 1074.26 | 3702.49 | ||
Maximum of Months | 0.00 | 0.00 | 58.59 | 58.59 | 1245.27 | 4021.56 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PACU_VAV_BOT
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.280338E+11 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.267425E+11 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.326228E+11 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.333216E+11 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.377700E+11 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.384036E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.300122E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.348132E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.316320E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.303468E+11 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.289101E+11 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.269138E+11 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.379522E+12 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.267425E+11 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.384036E+11 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PACU_VAV_MID
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.201358E+11 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.192429E+11 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.228319E+11 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.224600E+11 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.249974E+11 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.253875E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.206278E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.225703E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.208594E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.205218E+11 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.198204E+11 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.190293E+11 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.258484E+12 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.190293E+11 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.253875E+11 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PACU_VAV_TOP
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.250372E+11 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.245197E+11 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.300686E+11 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.311888E+11 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.346637E+11 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.351855E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.268453E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.307280E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.284208E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.269380E+11 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.255317E+11 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.239975E+11 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.343125E+12 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.239975E+11 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.351855E+11 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PACU_VAV_BOT
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.365997E+10 | 0.960654E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.345382E+10 | 0.904219E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.403057E+10 | 0.109718E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.375469E+10 | 0.114202E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.408445E+10 | 0.131386E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.433312E+10 | 0.132325E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.362990E+10 | 0.105765E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.384541E+10 | 0.124426E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.346458E+10 | 0.113150E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.343499E+10 | 0.109448E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.350899E+10 | 0.102340E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.334871E+10 | 0.942465E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.445492E+11 | 0.132349E+13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.334871E+10 | 0.904219E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.433312E+10 | 0.132325E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PACU_VAV_MID
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.291862E+10 | 0.668333E+11 | 0.00 | 0.00 | 0.158373E+11 | 0.00 | 0.00 | 0.00 |
February | 0.278751E+10 | 0.626716E+11 | 0.00 | 0.00 | 0.163824E+11 | 0.00 | 0.00 | 0.00 |
March | 0.317842E+10 | 0.736525E+11 | 0.00 | 0.00 | 0.221904E+11 | 0.00 | 0.00 | 0.00 |
April | 0.291156E+10 | 0.730702E+11 | 0.00 | 0.00 | 0.281148E+11 | 0.00 | 0.00 | 0.00 |
May | 0.314459E+10 | 0.823433E+11 | 0.00 | 0.00 | 0.332704E+11 | 0.00 | 0.00 | 0.00 |
June | 0.331204E+10 | 0.828892E+11 | 0.00 | 0.00 | 0.334842E+11 | 0.00 | 0.00 | 0.00 |
July | 0.270302E+10 | 0.706138E+11 | 0.00 | 0.00 | 0.204730E+11 | 0.00 | 0.00 | 0.00 |
August | 0.281318E+10 | 0.771222E+11 | 0.00 | 0.00 | 0.300659E+11 | 0.00 | 0.00 | 0.00 |
September | 0.258885E+10 | 0.713434E+11 | 0.00 | 0.00 | 0.266937E+11 | 0.00 | 0.00 | 0.00 |
October | 0.260906E+10 | 0.711869E+11 | 0.00 | 0.00 | 0.239266E+11 | 0.00 | 0.00 | 0.00 |
November | 0.270623E+10 | 0.675690E+11 | 0.00 | 0.00 | 0.204380E+11 | 0.00 | 0.00 | 0.00 |
December | 0.263230E+10 | 0.644455E+11 | 0.00 | 0.00 | 0.165469E+11 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.343054E+11 | 0.863741E+12 | 0.00 | 0.00 | 0.287423E+12 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.258885E+10 | 0.626716E+11 | 0.00 | 0.00 | 0.158373E+11 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.331204E+10 | 0.828892E+11 | 0.00 | 0.00 | 0.334842E+11 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PACU_VAV_TOP
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.284200E+10 | 0.873293E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.277271E+10 | 0.843344E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.325045E+10 | 0.103022E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.303208E+10 | 0.109308E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.319314E+10 | 0.123226E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.337173E+10 | 0.124218E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.269025E+10 | 0.971975E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.280181E+10 | 0.112907E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.261244E+10 | 0.104208E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.254052E+10 | 0.997182E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.262770E+10 | 0.925426E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.256616E+10 | 0.856935E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.343010E+11 | 0.122371E+13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.254052E+10 | 0.843344E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.337173E+10 | 0.124218E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PACU_VAV_BOT
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.365997E+10 | 0.00 | 0.00 | 0.00 | 0.243738E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.345382E+10 | 0.00 | 0.00 | 0.00 | 0.232887E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.403057E+10 | 0.00 | 0.00 | 0.00 | 0.285922E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.375469E+10 | 0.00 | 0.00 | 0.00 | 0.295669E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.408445E+10 | 0.00 | 0.00 | 0.00 | 0.336855E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.433312E+10 | 0.00 | 0.00 | 0.00 | 0.340704E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.362990E+10 | 0.00 | 0.00 | 0.00 | 0.263823E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.384541E+10 | 0.00 | 0.00 | 0.00 | 0.309678E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.346458E+10 | 0.00 | 0.00 | 0.00 | 0.281674E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.343499E+10 | 0.00 | 0.00 | 0.00 | 0.269118E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.350899E+10 | 0.00 | 0.00 | 0.00 | 0.254011E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.334871E+10 | 0.00 | 0.00 | 0.00 | 0.235651E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.445492E+11 | 0.00 | 0.00 | 0.00 | 0.334973E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.334871E+10 | 0.00 | 0.00 | 0.00 | 0.232887E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.433312E+10 | 0.00 | 0.00 | 0.00 | 0.340704E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PACU_VAV_MID
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.291862E+10 | 0.00 | 0.00 | 0.00 | 0.172171E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.278751E+10 | 0.00 | 0.00 | 0.00 | 0.164554E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.317842E+10 | 0.00 | 0.00 | 0.00 | 0.196535E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.291156E+10 | 0.00 | 0.00 | 0.00 | 0.195484E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.314459E+10 | 0.00 | 0.00 | 0.00 | 0.218528E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.331204E+10 | 0.00 | 0.00 | 0.00 | 0.220755E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.270302E+10 | 0.00 | 0.00 | 0.00 | 0.179248E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.281318E+10 | 0.00 | 0.00 | 0.00 | 0.197571E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.258885E+10 | 0.00 | 0.00 | 0.00 | 0.182706E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.260906E+10 | 0.00 | 0.00 | 0.00 | 0.179127E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.270623E+10 | 0.00 | 0.00 | 0.00 | 0.171141E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.263230E+10 | 0.00 | 0.00 | 0.00 | 0.163971E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.343054E+11 | 0.00 | 0.00 | 0.00 | 0.224179E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.258885E+10 | 0.00 | 0.00 | 0.00 | 0.163971E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.331204E+10 | 0.00 | 0.00 | 0.00 | 0.220755E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PACU_VAV_TOP
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.284200E+10 | 0.00 | 0.00 | 0.00 | 0.221952E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.277271E+10 | 0.00 | 0.00 | 0.00 | 0.217470E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.325045E+10 | 0.00 | 0.00 | 0.00 | 0.268182E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.303208E+10 | 0.00 | 0.00 | 0.00 | 0.281568E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.319314E+10 | 0.00 | 0.00 | 0.00 | 0.314706E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.337173E+10 | 0.00 | 0.00 | 0.00 | 0.318138E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.269025E+10 | 0.00 | 0.00 | 0.00 | 0.241551E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.280181E+10 | 0.00 | 0.00 | 0.00 | 0.279262E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.261244E+10 | 0.00 | 0.00 | 0.00 | 0.258084E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.254052E+10 | 0.00 | 0.00 | 0.00 | 0.243975E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.262770E+10 | 0.00 | 0.00 | 0.00 | 0.229040E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.256616E+10 | 0.00 | 0.00 | 0.00 | 0.214314E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.343010E+11 | 0.00 | 0.00 | 0.00 | 0.308824E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.254052E+10 | 0.00 | 0.00 | 0.00 | 0.214314E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.337173E+10 | 0.00 | 0.00 | 0.00 | 0.318138E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 766523.33 | 0.119644E+11 | 0.00 | 85228.81 | 0.244317E+10 | 0.00 | 161450.03 | 0.00 | 0.34 |
February | 0.00 | 0.113862E+11 | 0.00 | 0.00 | 0.264651E+10 | 0.00 | 0.00 | 0.00 | 0.34 |
March | 0.00 | 0.152605E+11 | 0.00 | 0.00 | 0.283175E+10 | 0.00 | 0.00 | 0.00 | 0.35 |
April | 0.00 | 0.178616E+11 | 0.00 | 0.00 | 0.447517E+10 | 0.00 | 0.00 | 0.00 | 0.34 |
May | 0.00 | 0.221523E+11 | 0.00 | 0.00 | 0.546564E+10 | 0.00 | 0.00 | 0.00 | 0.35 |
June | 0.00 | 0.223838E+11 | 0.00 | 0.00 | 0.449583E+10 | 0.00 | 0.00 | 0.00 | 0.34 |
July | 0.00 | 0.155067E+11 | 0.00 | 0.00 | 0.386326E+10 | 0.00 | 0.00 | 0.00 | 0.33 |
August | 0.00 | 0.221667E+11 | 0.00 | 0.00 | 0.371293E+10 | 0.00 | 0.00 | 0.00 | 0.34 |
September | 0.00 | 0.191029E+11 | 0.00 | 0.00 | 0.453398E+10 | 0.00 | 0.00 | 0.00 | 0.34 |
October | 0.00 | 0.185418E+11 | 0.00 | 0.00 | 0.376140E+10 | 0.00 | 0.00 | 0.00 | 0.33 |
November | 0.00 | 0.156831E+11 | 0.00 | 0.00 | 0.306645E+10 | 0.00 | 0.00 | 0.00 | 0.33 |
December | 0.00 | 0.123649E+11 | 0.00 | 0.00 | 0.312736E+10 | 0.00 | 0.00 | 0.00 | 0.34 |
Annual Sum or Average | 766523.33 | 0.204375E+12 | 0.00 | 85228.81 | 0.444234E+11 | 0.00 | 161450.03 | 0.00 | 0.34 |
Minimum of Months | 0.00 | 0.113862E+11 | 0.00 | 0.00 | 0.244317E+10 | 0.00 | 0.00 | 0.00 | 0.33 |
Maximum of Months | 766523.33 | 0.223838E+11 | 0.00 | 85228.81 | 0.546564E+10 | 0.00 | 161450.03 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 145584.79 | 0.485998E+10 | 0.00 | 41224.74 | 0.141950E+10 | 0.00 | 15593.58 | 0.00 | 0.31 |
February | 0.00 | 0.451055E+10 | 0.00 | 0.00 | 0.145280E+10 | 0.00 | 0.00 | 0.00 | 0.31 |
March | 0.00 | 0.566168E+10 | 0.00 | 0.00 | 0.147783E+10 | 0.00 | 0.00 | 0.00 | 0.33 |
April | 0.00 | 0.656815E+10 | 0.00 | 0.00 | 0.199205E+10 | 0.00 | 0.00 | 0.00 | 0.32 |
May | 0.00 | 0.879681E+10 | 0.00 | 0.00 | 0.242769E+10 | 0.00 | 0.00 | 0.00 | 0.33 |
June | 0.00 | 0.873510E+10 | 0.00 | 0.00 | 0.217176E+10 | 0.00 | 0.00 | 0.00 | 0.33 |
July | 0.00 | 0.697278E+10 | 0.00 | 0.00 | 0.211925E+10 | 0.00 | 0.00 | 0.00 | 0.31 |
August | 0.00 | 0.869680E+10 | 0.00 | 0.00 | 0.202692E+10 | 0.00 | 0.00 | 0.00 | 0.32 |
September | 0.00 | 0.777389E+10 | 0.00 | 0.00 | 0.227953E+10 | 0.00 | 0.00 | 0.00 | 0.32 |
October | 0.00 | 0.776909E+10 | 0.00 | 0.00 | 0.217006E+10 | 0.00 | 0.00 | 0.00 | 0.31 |
November | 0.00 | 0.652908E+10 | 0.00 | 0.00 | 0.164988E+10 | 0.00 | 0.00 | 0.00 | 0.31 |
December | 0.00 | 0.520284E+10 | 0.00 | 0.00 | 0.164004E+10 | 0.00 | 0.00 | 0.00 | 0.30 |
Annual Sum or Average | 145584.79 | 0.820768E+11 | 0.00 | 41224.74 | 0.228273E+11 | 0.00 | 15593.58 | 0.00 | 0.32 |
Minimum of Months | 0.00 | 0.451055E+10 | 0.00 | 0.00 | 0.141950E+10 | 0.00 | 0.00 | 0.00 | 0.30 |
Maximum of Months | 145584.79 | 0.879681E+10 | 0.00 | 41224.74 | 0.242769E+10 | 0.00 | 15593.58 | 0.00 | 0.33 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.105668E+11 | 0.00 | 0.00 | 0.239076E+10 | 0.00 | 0.00 | 0.00 | 0.30 |
February | 0.00 | 0.101606E+11 | 0.00 | 0.00 | 0.271421E+10 | 0.00 | 0.00 | 0.00 | 0.31 |
March | 0.00 | 0.136328E+11 | 0.00 | 0.00 | 0.295125E+10 | 0.00 | 0.00 | 0.00 | 0.32 |
April | 0.00 | 0.163145E+11 | 0.00 | 0.00 | 0.487300E+10 | 0.00 | 0.00 | 0.00 | 0.32 |
May | 0.00 | 0.204814E+11 | 0.00 | 0.00 | 0.575007E+10 | 0.00 | 0.00 | 0.00 | 0.33 |
June | 0.00 | 0.206640E+11 | 0.00 | 0.00 | 0.493978E+10 | 0.00 | 0.00 | 0.00 | 0.33 |
July | 0.00 | 0.142102E+11 | 0.00 | 0.00 | 0.406639E+10 | 0.00 | 0.00 | 0.00 | 0.31 |
August | 0.00 | 0.202452E+11 | 0.00 | 0.00 | 0.422934E+10 | 0.00 | 0.00 | 0.00 | 0.32 |
September | 0.00 | 0.175413E+11 | 0.00 | 0.00 | 0.481808E+10 | 0.00 | 0.00 | 0.00 | 0.32 |
October | 0.00 | 0.164643E+11 | 0.00 | 0.00 | 0.447263E+10 | 0.00 | 0.00 | 0.00 | 0.31 |
November | 0.00 | 0.139984E+11 | 0.00 | 0.00 | 0.333841E+10 | 0.00 | 0.00 | 0.00 | 0.30 |
December | 0.00 | 0.105589E+11 | 0.00 | 0.00 | 0.355751E+10 | 0.00 | 0.00 | 0.00 | 0.30 |
Annual Sum or Average | 0.00 | 0.184838E+12 | 0.00 | 0.00 | 0.481014E+11 | 0.00 | 0.00 | 0.00 | 0.31 |
Minimum of Months | 0.00 | 0.101606E+11 | 0.00 | 0.00 | 0.239076E+10 | 0.00 | 0.00 | 0.00 | 0.30 |
Maximum of Months | 0.00 | 0.206640E+11 | 0.00 | 0.00 | 0.575007E+10 | 0.00 | 0.00 | 0.00 | 0.33 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.306713E+10 | 0.00 | 0.00 | 0.474497E+09 | 0.00 | 0.00 | 0.00 | 0.39 |
February | 0.00 | 0.316596E+10 | 0.00 | 0.00 | 0.460138E+09 | 0.00 | 0.00 | 0.00 | 0.40 |
March | 0.00 | 0.439301E+10 | 0.00 | 0.00 | 0.470427E+09 | 0.00 | 0.00 | 0.00 | 0.44 |
April | 0.00 | 0.572590E+10 | 0.00 | 0.00 | 0.731415E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
May | 0.00 | 0.797568E+10 | 0.00 | 0.00 | 0.705921E+09 | 0.00 | 0.00 | 0.00 | 0.51 |
June | 0.00 | 0.873506E+10 | 0.00 | 0.00 | 0.497976E+09 | 0.00 | 0.00 | 0.00 | 0.54 |
July | 0.00 | 0.533800E+10 | 0.00 | 0.00 | 0.530709E+09 | 0.00 | 0.00 | 0.00 | 0.47 |
August | 0.00 | 0.691686E+10 | 0.00 | 0.00 | 0.610279E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
September | 0.00 | 0.578011E+10 | 0.00 | 0.00 | 0.737602E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
October | 0.00 | 0.511846E+10 | 0.00 | 0.00 | 0.683614E+09 | 0.00 | 0.00 | 0.00 | 0.40 |
November | 0.00 | 0.420344E+10 | 0.00 | 0.00 | 0.561670E+09 | 0.00 | 0.00 | 0.00 | 0.39 |
December | 0.00 | 0.312285E+10 | 0.00 | 0.00 | 0.645188E+09 | 0.00 | 0.00 | 0.00 | 0.38 |
Annual Sum or Average | 0.00 | 0.635424E+11 | 0.00 | 0.00 | 0.710944E+10 | 0.00 | 0.00 | 0.00 | 0.44 |
Minimum of Months | 0.00 | 0.306713E+10 | 0.00 | 0.00 | 0.460138E+09 | 0.00 | 0.00 | 0.00 | 0.38 |
Maximum of Months | 0.00 | 0.873506E+10 | 0.00 | 0.00 | 0.737602E+09 | 0.00 | 0.00 | 0.00 | 0.54 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.258168E+10 | 0.00 | 0.00 | 0.278908E+09 | 0.00 | 0.00 | 0.00 | 0.50 |
February | 0.00 | 0.273792E+10 | 0.00 | 0.00 | 0.228647E+09 | 0.00 | 0.00 | 0.00 | 0.54 |
March | 0.00 | 0.380344E+10 | 0.00 | 0.00 | 0.280133E+09 | 0.00 | 0.00 | 0.00 | 0.59 |
April | 0.00 | 0.485420E+10 | 0.00 | 0.00 | 0.472840E+09 | 0.00 | 0.00 | 0.00 | 0.60 |
May | 0.00 | 0.571649E+10 | 0.00 | 0.00 | 0.554385E+09 | 0.00 | 0.00 | 0.00 | 0.58 |
June | 0.00 | 0.590195E+10 | 0.00 | 0.00 | 0.446808E+09 | 0.00 | 0.00 | 0.00 | 0.59 |
July | 0.00 | 0.367329E+10 | 0.00 | 0.00 | 0.421930E+09 | 0.00 | 0.00 | 0.00 | 0.52 |
August | 0.00 | 0.532628E+10 | 0.00 | 0.00 | 0.431904E+09 | 0.00 | 0.00 | 0.00 | 0.55 |
September | 0.00 | 0.468099E+10 | 0.00 | 0.00 | 0.474005E+09 | 0.00 | 0.00 | 0.00 | 0.54 |
October | 0.00 | 0.411108E+10 | 0.00 | 0.00 | 0.448612E+09 | 0.00 | 0.00 | 0.00 | 0.50 |
November | 0.00 | 0.339076E+10 | 0.00 | 0.00 | 0.321656E+09 | 0.00 | 0.00 | 0.00 | 0.49 |
December | 0.00 | 0.266520E+10 | 0.00 | 0.00 | 0.341016E+09 | 0.00 | 0.00 | 0.00 | 0.48 |
Annual Sum or Average | 0.00 | 0.494433E+11 | 0.00 | 0.00 | 0.470084E+10 | 0.00 | 0.00 | 0.00 | 0.54 |
Minimum of Months | 0.00 | 0.258168E+10 | 0.00 | 0.00 | 0.228647E+09 | 0.00 | 0.00 | 0.00 | 0.48 |
Maximum of Months | 0.00 | 0.590195E+10 | 0.00 | 0.00 | 0.554385E+09 | 0.00 | 0.00 | 0.00 | 0.60 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.464385E+10 | 0.00 | 0.00 | 0.258431E+09 | 0.00 | 0.00 | 0.00 | 0.54 |
February | 0.00 | 0.443395E+10 | 0.00 | 0.00 | 0.294889E+09 | 0.00 | 0.00 | 0.00 | 0.53 |
March | 0.00 | 0.508011E+10 | 0.00 | 0.00 | 0.401776E+09 | 0.00 | 0.00 | 0.00 | 0.50 |
April | 0.00 | 0.559705E+10 | 0.00 | 0.00 | 0.756632E+09 | 0.00 | 0.00 | 0.00 | 0.45 |
May | 0.00 | 0.703500E+10 | 0.00 | 0.00 | 0.863373E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
June | 0.00 | 0.703154E+10 | 0.00 | 0.00 | 0.717268E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
July | 0.00 | 0.459112E+10 | 0.00 | 0.00 | 0.657130E+09 | 0.00 | 0.00 | 0.00 | 0.42 |
August | 0.00 | 0.648230E+10 | 0.00 | 0.00 | 0.643500E+09 | 0.00 | 0.00 | 0.00 | 0.44 |
September | 0.00 | 0.606906E+10 | 0.00 | 0.00 | 0.717170E+09 | 0.00 | 0.00 | 0.00 | 0.45 |
October | 0.00 | 0.616775E+10 | 0.00 | 0.00 | 0.520651E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
November | 0.00 | 0.572634E+10 | 0.00 | 0.00 | 0.345003E+09 | 0.00 | 0.00 | 0.00 | 0.50 |
December | 0.00 | 0.491094E+10 | 0.00 | 0.00 | 0.326482E+09 | 0.00 | 0.00 | 0.00 | 0.53 |
Annual Sum or Average | 0.00 | 0.677690E+11 | 0.00 | 0.00 | 0.650231E+10 | 0.00 | 0.00 | 0.00 | 0.48 |
Minimum of Months | 0.00 | 0.443395E+10 | 0.00 | 0.00 | 0.258431E+09 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 0.00 | 0.703500E+10 | 0.00 | 0.00 | 0.863373E+09 | 0.00 | 0.00 | 0.00 | 0.54 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.254586E+10 | 0.00 | 0.00 | 0.401706E+09 | 0.00 | 0.00 | 0.00 | 0.51 |
February | 0.00 | 0.268382E+10 | 0.00 | 0.00 | 0.413401E+09 | 0.00 | 0.00 | 0.00 | 0.54 |
March | 0.00 | 0.379352E+10 | 0.00 | 0.00 | 0.400279E+09 | 0.00 | 0.00 | 0.00 | 0.60 |
April | 0.00 | 0.475085E+10 | 0.00 | 0.00 | 0.613342E+09 | 0.00 | 0.00 | 0.00 | 0.61 |
May | 0.00 | 0.550458E+10 | 0.00 | 0.00 | 0.773375E+09 | 0.00 | 0.00 | 0.00 | 0.58 |
June | 0.00 | 0.566230E+10 | 0.00 | 0.00 | 0.625337E+09 | 0.00 | 0.00 | 0.00 | 0.59 |
July | 0.00 | 0.352876E+10 | 0.00 | 0.00 | 0.627072E+09 | 0.00 | 0.00 | 0.00 | 0.53 |
August | 0.00 | 0.511606E+10 | 0.00 | 0.00 | 0.611707E+09 | 0.00 | 0.00 | 0.00 | 0.56 |
September | 0.00 | 0.448267E+10 | 0.00 | 0.00 | 0.686463E+09 | 0.00 | 0.00 | 0.00 | 0.55 |
October | 0.00 | 0.391532E+10 | 0.00 | 0.00 | 0.748571E+09 | 0.00 | 0.00 | 0.00 | 0.51 |
November | 0.00 | 0.329739E+10 | 0.00 | 0.00 | 0.561875E+09 | 0.00 | 0.00 | 0.00 | 0.50 |
December | 0.00 | 0.254997E+10 | 0.00 | 0.00 | 0.583555E+09 | 0.00 | 0.00 | 0.00 | 0.50 |
Annual Sum or Average | 0.00 | 0.478311E+11 | 0.00 | 0.00 | 0.704668E+10 | 0.00 | 0.00 | 0.00 | 0.55 |
Minimum of Months | 0.00 | 0.254586E+10 | 0.00 | 0.00 | 0.400279E+09 | 0.00 | 0.00 | 0.00 | 0.50 |
Maximum of Months | 0.00 | 0.566230E+10 | 0.00 | 0.00 | 0.773375E+09 | 0.00 | 0.00 | 0.00 | 0.61 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 190025.97 | 0.258464E+10 | 0.00 | 0.00 | 0.562380E+09 | 0.00 | 0.00 | 0.00 | 0.35 |
February | 0.00 | 0.260426E+10 | 0.00 | 0.00 | 0.587295E+09 | 0.00 | 0.00 | 0.00 | 0.36 |
March | 0.00 | 0.357809E+10 | 0.00 | 0.00 | 0.641324E+09 | 0.00 | 0.00 | 0.00 | 0.38 |
April | 0.00 | 0.465061E+10 | 0.00 | 0.00 | 0.906453E+09 | 0.00 | 0.00 | 0.00 | 0.39 |
May | 0.00 | 0.665065E+10 | 0.00 | 0.00 | 0.845901E+09 | 0.00 | 0.00 | 0.00 | 0.44 |
June | 0.00 | 0.742418E+10 | 0.00 | 0.00 | 0.561489E+09 | 0.00 | 0.00 | 0.00 | 0.47 |
July | 0.00 | 0.459587E+10 | 0.00 | 0.00 | 0.635007E+09 | 0.00 | 0.00 | 0.00 | 0.42 |
August | 0.00 | 0.584132E+10 | 0.00 | 0.00 | 0.704880E+09 | 0.00 | 0.00 | 0.00 | 0.41 |
September | 0.00 | 0.481280E+10 | 0.00 | 0.00 | 0.933251E+09 | 0.00 | 0.00 | 0.00 | 0.38 |
October | 0.00 | 0.419018E+10 | 0.00 | 0.00 | 0.828251E+09 | 0.00 | 0.00 | 0.00 | 0.35 |
November | 0.00 | 0.345232E+10 | 0.00 | 0.00 | 0.704883E+09 | 0.00 | 0.00 | 0.00 | 0.35 |
December | 0.00 | 0.266979E+10 | 0.00 | 0.00 | 0.709795E+09 | 0.00 | 0.00 | 0.00 | 0.34 |
Annual Sum or Average | 190025.97 | 0.530547E+11 | 0.00 | 0.00 | 0.862091E+10 | 0.00 | 0.00 | 0.00 | 0.39 |
Minimum of Months | 0.00 | 0.258464E+10 | 0.00 | 0.00 | 0.561489E+09 | 0.00 | 0.00 | 0.00 | 0.34 |
Maximum of Months | 190025.97 | 0.742418E+10 | 0.00 | 0.00 | 0.933251E+09 | 0.00 | 0.00 | 0.00 | 0.47 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 124734.47 | 0.217329E+10 | 0.00 | 1469.44 | 0.320997E+09 | 0.00 | 3852.50 | 0.00 | 0.44 |
February | 0.00 | 0.230637E+10 | 0.00 | 0.00 | 0.275576E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
March | 0.00 | 0.324583E+10 | 0.00 | 0.00 | 0.274866E+09 | 0.00 | 0.00 | 0.00 | 0.50 |
April | 0.00 | 0.414026E+10 | 0.00 | 0.00 | 0.389584E+09 | 0.00 | 0.00 | 0.00 | 0.51 |
May | 0.00 | 0.485510E+10 | 0.00 | 0.00 | 0.491671E+09 | 0.00 | 0.00 | 0.00 | 0.49 |
June | 0.00 | 0.501275E+10 | 0.00 | 0.00 | 0.386497E+09 | 0.00 | 0.00 | 0.00 | 0.50 |
July | 0.00 | 0.315849E+10 | 0.00 | 0.00 | 0.405112E+09 | 0.00 | 0.00 | 0.00 | 0.45 |
August | 0.00 | 0.452780E+10 | 0.00 | 0.00 | 0.370338E+09 | 0.00 | 0.00 | 0.00 | 0.48 |
September | 0.00 | 0.402615E+10 | 0.00 | 0.00 | 0.421866E+09 | 0.00 | 0.00 | 0.00 | 0.47 |
October | 0.00 | 0.343676E+10 | 0.00 | 0.00 | 0.413709E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
November | 0.00 | 0.279804E+10 | 0.00 | 0.00 | 0.369364E+09 | 0.00 | 0.00 | 0.00 | 0.42 |
December | 0.00 | 0.227483E+10 | 0.00 | 0.00 | 0.362177E+09 | 0.00 | 0.00 | 0.00 | 0.42 |
Annual Sum or Average | 124734.47 | 0.419557E+11 | 0.00 | 1469.44 | 0.448176E+10 | 0.00 | 3852.50 | 0.00 | 0.47 |
Minimum of Months | 0.00 | 0.217329E+10 | 0.00 | 0.00 | 0.274866E+09 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 124734.47 | 0.501275E+10 | 0.00 | 1469.44 | 0.491671E+09 | 0.00 | 3852.50 | 0.00 | 0.51 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 161547.72 | 0.440192E+10 | 0.00 | 11281.72 | 0.300661E+09 | 0.00 | 29784.96 | 0.00 | 0.52 |
February | 0.00 | 0.420087E+10 | 0.00 | 0.00 | 0.330241E+09 | 0.00 | 0.00 | 0.00 | 0.50 |
March | 0.00 | 0.514276E+10 | 0.00 | 0.00 | 0.460041E+09 | 0.00 | 0.00 | 0.00 | 0.51 |
April | 0.00 | 0.572076E+10 | 0.00 | 0.00 | 0.865673E+09 | 0.00 | 0.00 | 0.00 | 0.47 |
May | 0.00 | 0.715143E+10 | 0.00 | 0.00 | 0.100267E+10 | 0.00 | 0.00 | 0.00 | 0.48 |
June | 0.00 | 0.719852E+10 | 0.00 | 0.00 | 0.861626E+09 | 0.00 | 0.00 | 0.00 | 0.48 |
July | 0.00 | 0.456879E+10 | 0.00 | 0.00 | 0.776287E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
August | 0.00 | 0.662692E+10 | 0.00 | 0.00 | 0.751351E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
September | 0.00 | 0.602596E+10 | 0.00 | 0.00 | 0.858290E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
October | 0.00 | 0.595388E+10 | 0.00 | 0.00 | 0.582735E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
November | 0.00 | 0.551144E+10 | 0.00 | 0.00 | 0.373346E+09 | 0.00 | 0.00 | 0.00 | 0.49 |
December | 0.00 | 0.467504E+10 | 0.00 | 0.00 | 0.367331E+09 | 0.00 | 0.00 | 0.00 | 0.51 |
Annual Sum or Average | 161547.72 | 0.671783E+11 | 0.00 | 11281.72 | 0.753025E+10 | 0.00 | 29784.96 | 0.00 | 0.48 |
Minimum of Months | 0.00 | 0.420087E+10 | 0.00 | 0.00 | 0.300661E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
Maximum of Months | 161547.72 | 0.719852E+10 | 0.00 | 11281.72 | 0.100267E+10 | 0.00 | 29784.96 | 0.00 | 0.52 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 133172.01 | 0.219691E+10 | 0.00 | 2362.41 | 0.332142E+09 | 0.00 | 5014.73 | 0.00 | 0.44 |
February | 0.00 | 0.232212E+10 | 0.00 | 0.00 | 0.329539E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
March | 0.00 | 0.329377E+10 | 0.00 | 0.00 | 0.313402E+09 | 0.00 | 0.00 | 0.00 | 0.51 |
April | 0.00 | 0.411059E+10 | 0.00 | 0.00 | 0.442149E+09 | 0.00 | 0.00 | 0.00 | 0.51 |
May | 0.00 | 0.473268E+10 | 0.00 | 0.00 | 0.582623E+09 | 0.00 | 0.00 | 0.00 | 0.49 |
June | 0.00 | 0.492894E+10 | 0.00 | 0.00 | 0.442909E+09 | 0.00 | 0.00 | 0.00 | 0.50 |
July | 0.00 | 0.311456E+10 | 0.00 | 0.00 | 0.459177E+09 | 0.00 | 0.00 | 0.00 | 0.45 |
August | 0.00 | 0.444260E+10 | 0.00 | 0.00 | 0.419151E+09 | 0.00 | 0.00 | 0.00 | 0.48 |
September | 0.00 | 0.389697E+10 | 0.00 | 0.00 | 0.520215E+09 | 0.00 | 0.00 | 0.00 | 0.47 |
October | 0.00 | 0.338973E+10 | 0.00 | 0.00 | 0.473888E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
November | 0.00 | 0.279846E+10 | 0.00 | 0.00 | 0.426846E+09 | 0.00 | 0.00 | 0.00 | 0.42 |
December | 0.00 | 0.227197E+10 | 0.00 | 0.00 | 0.405497E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
Annual Sum or Average | 133172.01 | 0.414993E+11 | 0.00 | 2362.41 | 0.514754E+10 | 0.00 | 5014.73 | 0.00 | 0.47 |
Minimum of Months | 0.00 | 0.219691E+10 | 0.00 | 0.00 | 0.313402E+09 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 133172.01 | 0.492894E+10 | 0.00 | 2362.41 | 0.582623E+09 | 0.00 | 5014.73 | 0.00 | 0.51 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 34585.24 | 0.135207E+10 | 0.00 | 178.67 | 0.300174E+09 | 0.00 | 291.81 | 0.00 | 0.39 |
February | 0.00 | 0.132506E+10 | 0.00 | 0.00 | 0.298879E+09 | 0.00 | 0.00 | 0.00 | 0.41 |
March | 0.00 | 0.176887E+10 | 0.00 | 0.00 | 0.280214E+09 | 0.00 | 0.00 | 0.00 | 0.45 |
April | 0.00 | 0.225180E+10 | 0.00 | 0.00 | 0.344468E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
May | 0.00 | 0.329042E+10 | 0.00 | 0.00 | 0.350689E+09 | 0.00 | 0.00 | 0.00 | 0.51 |
June | 0.00 | 0.360361E+10 | 0.00 | 0.00 | 0.266170E+09 | 0.00 | 0.00 | 0.00 | 0.55 |
July | 0.00 | 0.242054E+10 | 0.00 | 0.00 | 0.346637E+09 | 0.00 | 0.00 | 0.00 | 0.47 |
August | 0.00 | 0.289820E+10 | 0.00 | 0.00 | 0.338861E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
September | 0.00 | 0.242693E+10 | 0.00 | 0.00 | 0.437187E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
October | 0.00 | 0.223841E+10 | 0.00 | 0.00 | 0.430616E+09 | 0.00 | 0.00 | 0.00 | 0.40 |
November | 0.00 | 0.184326E+10 | 0.00 | 0.00 | 0.344791E+09 | 0.00 | 0.00 | 0.00 | 0.40 |
December | 0.00 | 0.141277E+10 | 0.00 | 0.00 | 0.348598E+09 | 0.00 | 0.00 | 0.00 | 0.38 |
Annual Sum or Average | 34585.24 | 0.268319E+11 | 0.00 | 178.67 | 0.408728E+10 | 0.00 | 291.81 | 0.00 | 0.44 |
Minimum of Months | 0.00 | 0.132506E+10 | 0.00 | 0.00 | 0.266170E+09 | 0.00 | 0.00 | 0.00 | 0.38 |
Maximum of Months | 34585.24 | 0.360361E+10 | 0.00 | 178.67 | 0.437187E+09 | 0.00 | 291.81 | 0.00 | 0.55 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 26486.82 | 0.114389E+10 | 0.00 | 135.14 | 0.193967E+09 | 0.00 | 225.18 | 0.00 | 0.50 |
February | 0.00 | 0.117021E+10 | 0.00 | 0.00 | 0.161557E+09 | 0.00 | 0.00 | 0.00 | 0.53 |
March | 0.00 | 0.152144E+10 | 0.00 | 0.00 | 0.170664E+09 | 0.00 | 0.00 | 0.00 | 0.59 |
April | 0.00 | 0.190881E+10 | 0.00 | 0.00 | 0.206506E+09 | 0.00 | 0.00 | 0.00 | 0.60 |
May | 0.00 | 0.233268E+10 | 0.00 | 0.00 | 0.259149E+09 | 0.00 | 0.00 | 0.00 | 0.57 |
June | 0.00 | 0.239454E+10 | 0.00 | 0.00 | 0.230885E+09 | 0.00 | 0.00 | 0.00 | 0.59 |
July | 0.00 | 0.163224E+10 | 0.00 | 0.00 | 0.283170E+09 | 0.00 | 0.00 | 0.00 | 0.51 |
August | 0.00 | 0.218284E+10 | 0.00 | 0.00 | 0.245239E+09 | 0.00 | 0.00 | 0.00 | 0.55 |
September | 0.00 | 0.194671E+10 | 0.00 | 0.00 | 0.270766E+09 | 0.00 | 0.00 | 0.00 | 0.53 |
October | 0.00 | 0.176320E+10 | 0.00 | 0.00 | 0.288665E+09 | 0.00 | 0.00 | 0.00 | 0.49 |
November | 0.00 | 0.147479E+10 | 0.00 | 0.00 | 0.209286E+09 | 0.00 | 0.00 | 0.00 | 0.48 |
December | 0.00 | 0.120062E+10 | 0.00 | 0.00 | 0.207840E+09 | 0.00 | 0.00 | 0.00 | 0.48 |
Annual Sum or Average | 26486.82 | 0.206720E+11 | 0.00 | 135.14 | 0.272769E+10 | 0.00 | 225.18 | 0.00 | 0.54 |
Minimum of Months | 0.00 | 0.114389E+10 | 0.00 | 0.00 | 0.161557E+09 | 0.00 | 0.00 | 0.00 | 0.48 |
Maximum of Months | 26486.82 | 0.239454E+10 | 0.00 | 135.14 | 0.288665E+09 | 0.00 | 225.18 | 0.00 | 0.60 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 30712.10 | 0.201442E+10 | 0.00 | 2073.63 | 0.199776E+09 | 0.00 | 2520.93 | 0.00 | 0.54 |
February | 0.00 | 0.186157E+10 | 0.00 | 0.00 | 0.209583E+09 | 0.00 | 0.00 | 0.00 | 0.53 |
March | 0.00 | 0.206159E+10 | 0.00 | 0.00 | 0.234426E+09 | 0.00 | 0.00 | 0.00 | 0.50 |
April | 0.00 | 0.220718E+10 | 0.00 | 0.00 | 0.351048E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
May | 0.00 | 0.290923E+10 | 0.00 | 0.00 | 0.414916E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
June | 0.00 | 0.287898E+10 | 0.00 | 0.00 | 0.387993E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
July | 0.00 | 0.208890E+10 | 0.00 | 0.00 | 0.413584E+09 | 0.00 | 0.00 | 0.00 | 0.42 |
August | 0.00 | 0.270624E+10 | 0.00 | 0.00 | 0.369835E+09 | 0.00 | 0.00 | 0.00 | 0.44 |
September | 0.00 | 0.255684E+10 | 0.00 | 0.00 | 0.416703E+09 | 0.00 | 0.00 | 0.00 | 0.45 |
October | 0.00 | 0.268420E+10 | 0.00 | 0.00 | 0.351363E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
November | 0.00 | 0.250816E+10 | 0.00 | 0.00 | 0.221979E+09 | 0.00 | 0.00 | 0.00 | 0.50 |
December | 0.00 | 0.216626E+10 | 0.00 | 0.00 | 0.209673E+09 | 0.00 | 0.00 | 0.00 | 0.53 |
Annual Sum or Average | 30712.10 | 0.286436E+11 | 0.00 | 2073.63 | 0.378088E+10 | 0.00 | 2520.93 | 0.00 | 0.48 |
Minimum of Months | 0.00 | 0.186157E+10 | 0.00 | 0.00 | 0.199776E+09 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 30712.10 | 0.290923E+10 | 0.00 | 2073.63 | 0.416703E+09 | 0.00 | 2520.93 | 0.00 | 0.54 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 25275.59 | 0.110383E+10 | 0.00 | 647.17 | 0.235393E+09 | 0.00 | 3022.41 | 0.00 | 0.51 |
February | 0.00 | 0.113105E+10 | 0.00 | 0.00 | 0.222791E+09 | 0.00 | 0.00 | 0.00 | 0.54 |
March | 0.00 | 0.155428E+10 | 0.00 | 0.00 | 0.197487E+09 | 0.00 | 0.00 | 0.00 | 0.60 |
April | 0.00 | 0.190623E+10 | 0.00 | 0.00 | 0.239410E+09 | 0.00 | 0.00 | 0.00 | 0.60 |
May | 0.00 | 0.229466E+10 | 0.00 | 0.00 | 0.324048E+09 | 0.00 | 0.00 | 0.00 | 0.58 |
June | 0.00 | 0.235915E+10 | 0.00 | 0.00 | 0.279370E+09 | 0.00 | 0.00 | 0.00 | 0.59 |
July | 0.00 | 0.163533E+10 | 0.00 | 0.00 | 0.315380E+09 | 0.00 | 0.00 | 0.00 | 0.52 |
August | 0.00 | 0.217552E+10 | 0.00 | 0.00 | 0.272875E+09 | 0.00 | 0.00 | 0.00 | 0.55 |
September | 0.00 | 0.190996E+10 | 0.00 | 0.00 | 0.327737E+09 | 0.00 | 0.00 | 0.00 | 0.54 |
October | 0.00 | 0.177205E+10 | 0.00 | 0.00 | 0.329980E+09 | 0.00 | 0.00 | 0.00 | 0.50 |
November | 0.00 | 0.145973E+10 | 0.00 | 0.00 | 0.272343E+09 | 0.00 | 0.00 | 0.00 | 0.50 |
December | 0.00 | 0.115261E+10 | 0.00 | 0.00 | 0.269980E+09 | 0.00 | 0.00 | 0.00 | 0.49 |
Annual Sum or Average | 25275.59 | 0.204544E+11 | 0.00 | 647.17 | 0.328679E+10 | 0.00 | 3022.41 | 0.00 | 0.54 |
Minimum of Months | 0.00 | 0.110383E+10 | 0.00 | 0.00 | 0.197487E+09 | 0.00 | 0.00 | 0.00 | 0.49 |
Maximum of Months | 25275.59 | 0.235915E+10 | 0.00 | 647.17 | 0.329980E+09 | 0.00 | 3022.41 | 0.00 | 0.60 |
Report: HeatEmissionsReportMonthly
For: Environment
Timestamp: 2023-10-16 08:35:24
Custom Monthly ReportSITE TOTAL SURFACE HEAT EMISSION TO AIR [J] | SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] | SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] | AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] | HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J] | |
January | 0.240312E+12 | -0.609073E+10 | 0.00 | -0.125786E+12 | 0.314014E+12 |
February | 0.234001E+12 | -0.597556E+10 | 0.00 | -0.125729E+12 | 0.298919E+12 |
March | 0.298533E+12 | -0.919484E+10 | 0.00 | -0.157686E+12 | 0.361457E+12 |
April | 0.293698E+12 | -0.998648E+10 | 0.00 | -0.200645E+12 | 0.373852E+12 |
May | 0.295776E+12 | -0.125571E+11 | 0.00 | -0.244357E+12 | 0.423965E+12 |
June | 0.306772E+12 | -0.125073E+11 | 0.00 | -0.237532E+12 | 0.427392E+12 |
July | 0.255454E+12 | -0.775059E+10 | 0.00 | -0.175993E+12 | 0.342038E+12 |
August | 0.316473E+12 | -0.117565E+11 | 0.00 | -0.222435E+12 | 0.393106E+12 |
September | 0.250743E+12 | -0.920950E+10 | 0.00 | -0.207995E+12 | 0.360948E+12 |
October | 0.277105E+12 | -0.892816E+10 | 0.00 | -0.198267E+12 | 0.349575E+12 |
November | 0.230466E+12 | -0.773830E+10 | 0.00 | -0.166863E+12 | 0.327871E+12 |
December | 0.226995E+12 | -0.570341E+10 | 0.00 | -0.138819E+12 | 0.305779E+12 |
Annual Sum or Average | 0.322633E+13 | -0.107398E+12 | 0.00 | -0.220211E+13 | 0.427892E+13 |
Minimum of Months | 0.226995E+12 | -0.125571E+11 | 0.00 | -0.244357E+12 | 0.298919E+12 |