Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 08:35
Tabular Output Report in Format: HTML
Building: OfficeMedium
Environment: RUNPERIOD 1 ** Tucson-Davis Monthan AFB AZ USA TMY3 WMO#=722745
Simulation Timestamp: 2023-10-16 08:35:20
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1641.82 | 329.54 | 329.54 |
Net Site Energy | 1641.82 | 329.54 | 329.54 |
Total Source Energy | 4996.75 | 1002.92 | 1002.92 |
Net Source Energy | 4996.75 | 1002.92 | 1002.92 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 1.200 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil No 1 | 1.050 |
Fuel Oil No 2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 4982.19 |
Net Conditioned Building Area | 4982.19 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 9.10 | 3.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 426.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 202.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 49.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 705.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 11.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 138.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 94.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 271.06 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1544.41 | 97.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 271.06 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 9.10 | 3.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 426.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 202.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 49.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 584.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ElevatorLift | 120.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ElevatorLightsFan | 0.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Equipment | Transformer | 11.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 138.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 271.06 | |
Water Heater | 0.00 | 94.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | Unassigned | 9.10 | 3.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | Unassigned | 426.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GENERAL | 202.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | Unassigned | 49.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | GENERAL | 705.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | Unassigned | 11.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Unassigned | 138.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | Unassigned | 0.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Unassigned | 0.00 | 94.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 271.06 |
Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 50.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 115.30 | 19.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 |
Other | 143.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 309.99 | 19.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 50.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 115.30 | 19.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 |
Other | 143.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 309.99 | 19.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 1544.412 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 1544.412 | 100.00 |
Total On-Site and Utility Electric Sources | 1544.412 | 100.00 |
Total Electricity End Uses | 1544.412 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 271.06 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 271.06 | 100.00 |
Total Water End Uses | 271.06 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 80.00 |
Time Setpoint Not Met During Occupied Cooling | 504.67 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 919.33 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Environment |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2021
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Environment |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME OFFICEMEDIUM
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 2B
| Environment |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_AZ_TUCSON
| Environment |ZoneCoolingSummaryMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |ZoneHeatingSummaryMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |ZoneElectricSummaryMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |SpaceGainsMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | FIRSTFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM |PeakSpaceGainsMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | FIRSTFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM |SpaceGainComponentsAtCoolingPeakMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |ComfortReportSimple55Monthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |OccupantComfortDataSummaryMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |DXReportMonthly
| PACU_VAV_BOT COOLING COIL | PACU_VAV_MID COOLING COIL | PACU_VAV_TOP COOLING COIL |WindowReportMonthly
| PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW |WindowEnergyReportMonthly
| PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW |WindowZoneSummaryMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |WindowEnergyZoneSummaryMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| SWHSYS1 WATER HEATER |DaylightingReportMonthly
| PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_4_DAYLCTRL |CoilReportMonthly
| CORE_BOTTOM VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | CORE_MID VAV BOX REHEAT COIL | PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | CORE_TOP VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | PACU_VAV_BOT HEATING COIL | PACU_VAV_MID HEATING COIL | PACU_VAV_TOP HEATING COIL | PACU_VAV_BOT COOLING COIL | PACU_VAV_MID COOLING COIL | PACU_VAV_TOP COOLING COIL |PlantLoopDemandReportMonthly
| SWHSYS1 |FanReportMonthly
| PACU_VAV_BOT FAN | PACU_VAV_MID FAN | PACU_VAV_TOP FAN |PumpReportMonthly
| SWHSYS1 PUMP |CondLoopDemandReportMonthly
| SWHSYS1 |ZoneTemperatureOscillationReportMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |AirLoopSystemEnergyAndWaterUseMonthly
| PACU_VAV_BOT | PACU_VAV_MID | PACU_VAV_TOP |AirLoopSystemComponentLoadsMonthly
| PACU_VAV_BOT | PACU_VAV_MID | PACU_VAV_TOP |AirLoopSystemComponentEnergyUseMonthly
| PACU_VAV_BOT | PACU_VAV_MID | PACU_VAV_TOP |MechanicalVentilationLoadsMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |HeatEmissionsReportMonthly
| Environment |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
GeneralValue | |
Program Version and Build | EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 08:35 |
RunPeriod | RUNPERIOD 1 |
Weather File | Tucson-Davis Monthan AFB AZ USA TMY3 WMO#=722745 |
Latitude [deg] | 32.17 |
Longitude [deg] | -110.9 |
Elevation [m] | 809.00 |
Time Zone | -7.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1977.67 | 593.30 | 395.53 | 593.30 | 395.53 |
Above Ground Wall Area [m2] | 1977.67 | 593.30 | 395.53 | 593.30 | 395.53 |
Window Opening Area [m2] | 593.29 | 177.99 | 118.66 | 177.99 | 118.66 |
Gross Window-Wall Ratio [%] | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 |
Above Ground Window-Wall Ratio [%] | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1977.67 | 593.30 | 395.53 | 593.30 | 395.53 |
Above Ground Wall Area [m2] | 1977.67 | 593.30 | 395.53 | 593.30 | 395.53 |
Window Opening Area [m2] | 593.29 | 177.99 | 118.66 | 177.99 | 118.66 |
Gross Window-Wall Ratio [%] | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 |
Above Ground Window-Wall Ratio [%] | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 |
Total | |
Gross Roof Area [m2] | 1660.73 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
CORE_BOTTOM | 983.54 | Yes | Yes | 2698.04 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.9322 | 18.58 | 24.8342 |
TOPFLOOR_PLENUM | 1660.73 | Yes | No | 2024.76 | 1.00 | 202.84 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 | |
MIDFLOOR_PLENUM | 1660.73 | Yes | No | 2024.76 | 1.00 | 202.84 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 | |
FIRSTFLOOR_PLENUM | 1660.73 | Yes | No | 2024.76 | 1.00 | 202.84 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 | |
CORE_MID | 983.54 | Yes | Yes | 2698.04 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.9322 | 18.58 | 8.0700 |
CORE_TOP | 983.54 | Yes | Yes | 2698.04 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.9322 | 18.58 | 8.0700 |
PERIMETER_TOP_ZN_3 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 59.33 | 59.33 | 5.9322 | 18.58 | 8.0700 |
PERIMETER_TOP_ZN_2 | 131.26 | Yes | Yes | 360.08 | 1.00 | 91.28 | 0.00 | 39.55 | 39.55 | 5.9322 | 18.58 | 8.0695 |
PERIMETER_TOP_ZN_1 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 59.33 | 59.33 | 5.9322 | 18.58 | 8.0699 |
PERIMETER_TOP_ZN_4 | 131.25 | Yes | Yes | 360.05 | 1.00 | 91.28 | 0.00 | 39.55 | 39.55 | 5.9322 | 18.58 | 8.0700 |
PERIMETER_BOT_ZN_3 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 59.33 | 59.33 | 5.9322 | 18.58 | 8.0700 |
PERIMETER_BOT_ZN_2 | 131.26 | Yes | Yes | 360.08 | 1.00 | 91.28 | 0.00 | 39.55 | 39.55 | 5.9322 | 18.58 | 8.0695 |
PERIMETER_BOT_ZN_1 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 59.33 | 59.33 | 5.9322 | 18.58 | 8.0699 |
PERIMETER_BOT_ZN_4 | 131.25 | Yes | Yes | 360.05 | 1.00 | 91.28 | 0.00 | 39.55 | 39.55 | 5.9322 | 18.58 | 8.0700 |
PERIMETER_MID_ZN_3 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 59.33 | 59.33 | 5.9322 | 18.58 | 8.0700 |
PERIMETER_MID_ZN_2 | 131.26 | Yes | Yes | 360.08 | 1.00 | 91.28 | 0.00 | 39.55 | 39.55 | 5.9322 | 18.58 | 8.0695 |
PERIMETER_MID_ZN_1 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 59.33 | 59.33 | 5.9322 | 18.58 | 8.0699 |
PERIMETER_MID_ZN_4 | 131.25 | Yes | Yes | 360.05 | 1.00 | 91.28 | 0.00 | 39.55 | 39.55 | 5.9322 | 18.58 | 8.0700 |
Total | 4982.19 | 13667.13 | 1369.16 | 0.00 | 593.29 | 593.29 | 5.9322 | 18.58 | 11.3794 | |||
Conditioned Total | 4982.19 | 13667.13 | 1369.16 | 0.00 | 593.29 | 593.29 | 5.9322 | 18.58 | 11.3794 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 4982.19 | 6074.28 | 608.51 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
CORE_BOTTOM | 983.54 | Yes | Yes | 1.00 | CORE_BOTTOM | GENERAL | CORE_BOTTOM | 5.9322 | 18.58 | 24.8342 | |
TOPFLOOR_PLENUM | 1660.73 | Yes | No | 1.00 | TOPFLOOR_PLENUM | GENERAL | TOPFLOOR_PLENUM | 0.0000 | 0.00 | 0.0000 | |
MIDFLOOR_PLENUM | 1660.73 | Yes | No | 1.00 | MIDFLOOR_PLENUM | GENERAL | MIDFLOOR_PLENUM | 0.0000 | 0.00 | 0.0000 | |
FIRSTFLOOR_PLENUM | 1660.73 | Yes | No | 1.00 | FIRSTFLOOR_PLENUM | GENERAL | FIRSTFLOOR_PLENUM | 0.0000 | 0.00 | 0.0000 | |
CORE_MID | 983.54 | Yes | Yes | 1.00 | CORE_MID | GENERAL | CORE_MID | 5.9322 | 18.58 | 8.0700 | |
CORE_TOP | 983.54 | Yes | Yes | 1.00 | CORE_TOP | GENERAL | CORE_TOP | 5.9322 | 18.58 | 8.0700 | |
PERIMETER_TOP_ZN_3 | 207.34 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_3 | GENERAL | PERIMETER_TOP_ZN_3 | 5.9322 | 18.58 | 8.0700 | |
PERIMETER_TOP_ZN_2 | 131.26 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_2 | GENERAL | PERIMETER_TOP_ZN_2 | 5.9322 | 18.58 | 8.0695 | |
PERIMETER_TOP_ZN_1 | 207.34 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_1 | GENERAL | PERIMETER_TOP_ZN_1 | 5.9322 | 18.58 | 8.0699 | |
PERIMETER_TOP_ZN_4 | 131.25 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_4 | GENERAL | PERIMETER_TOP_ZN_4 | 5.9322 | 18.58 | 8.0700 | |
PERIMETER_BOT_ZN_3 | 207.34 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_3 | GENERAL | PERIMETER_BOT_ZN_3 | 5.9322 | 18.58 | 8.0700 | |
PERIMETER_BOT_ZN_2 | 131.26 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_2 | GENERAL | PERIMETER_BOT_ZN_2 | 5.9322 | 18.58 | 8.0695 | |
PERIMETER_BOT_ZN_1 | 207.34 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_1 | GENERAL | PERIMETER_BOT_ZN_1 | 5.9322 | 18.58 | 8.0699 | |
PERIMETER_BOT_ZN_4 | 131.25 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_4 | GENERAL | PERIMETER_BOT_ZN_4 | 5.9322 | 18.58 | 8.0700 | |
PERIMETER_MID_ZN_3 | 207.34 | Yes | Yes | 1.00 | PERIMETER_MID_ZN_3 | GENERAL | PERIMETER_MID_ZN_3 | 5.9322 | 18.58 | 8.0700 | |
PERIMETER_MID_ZN_2 | 131.26 | Yes | Yes | 1.00 | PERIMETER_MID_ZN_2 | GENERAL | PERIMETER_MID_ZN_2 | 5.9322 | 18.58 | 8.0695 | |
PERIMETER_MID_ZN_1 | 207.34 | Yes | Yes | 1.00 | PERIMETER_MID_ZN_1 | GENERAL | PERIMETER_MID_ZN_1 | 5.9322 | 18.58 | 8.0699 | |
PERIMETER_MID_ZN_4 | 131.25 | Yes | Yes | 1.00 | PERIMETER_MID_ZN_4 | GENERAL | PERIMETER_MID_ZN_4 | 5.9322 | 18.58 | 8.0700 | |
Total | 4982.19 | 5.9322 | 9.29 | 11.3794 | |||||||
Conditioned Total | 4982.19 | 5.9322 | 9.29 | 11.3794 | |||||||
Unconditioned Total | 0.00 | 0.0000 | 0.00 | 0.0000 | |||||||
Not Part of Total | 4982.19 | 0.0000 | 0.00 | 0.0000 |
Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
GENERAL | 4982.19 | 4982.19 | 0.00 | 4982.19 | 5.9322 | 18.58 | 11.3794 |
Total | 4982.19 | 4982.19 | 0.00 | 4982.19 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
End UsesElectricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 28-JUN-15:09 | 05-DEC-07:19 | - | - | - | - | - | - | - | - | - | - | 01-FEB-12:09 |
Heating | 0.00 | 29671.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 89526.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 16818.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 42072.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 827.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 23182.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 8044.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 172428.96 | 37715.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 29671.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 89526.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 16818.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 34487.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ElevatorLift | 7527.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ElevatorLightsFan | 57.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Equipment | Transformer | 827.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 23182.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Water Heater | 0.00 | 8044.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 28.83 | 3.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 1351.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 642.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 157.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 2234.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 36.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 439.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 102.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 4891.15 | 105.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 5.79 | 0.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 271.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 129.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 31.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 448.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 7.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 88.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 20.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 981.73 | 21.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 5.79 | 0.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 271.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 129.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 31.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 448.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 7.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 88.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 20.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 981.73 | 21.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
AirTerminal:SingleDuct:VAV:ReheatDesign Size Maximum Air Flow Rate [m3/s] | Design Size Constant Minimum Air Flow Fraction | User-Specified Constant Minimum Air Flow Fraction | Design Size Minimum Air Flow Rate [m3/s] | Design Size Maximum Flow Fraction during Reheat [] | User-Specified Maximum Flow Fraction during Reheat [] | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | |
CORE_BOTTOM VAV BOX COMPONENT | 3.01 | 0.248922 | 0.264000 | 0.794850 | 0.663793 | 0.500000 | 0.001531 |
CORE_MID VAV BOX COMPONENT | 2.20 | 0.340273 | 0.346000 | 0.762070 | 0.907393 | 0.500000 | 0.001120 |
CORE_TOP VAV BOX COMPONENT | 2.42 | 0.309400 | 0.331000 | 0.801776 | 0.825067 | 0.500000 | 0.001231 |
PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | 0.828336 | 0.190734 | 0.204000 | 0.168981 | 0.508623 | 0.500000 | 0.001998 |
PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | 0.742881 | 0.134640 | 0.200000 | 0.148576 | 0.359041 | 0.500000 | 0.002830 |
PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | 0.920654 | 0.171608 | 0.200000 | 0.184131 | 0.457622 | 0.500000 | 0.002220 |
PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | 0.843055 | 0.118634 | 0.200000 | 0.168611 | 0.316358 | 0.500000 | 0.003212 |
PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | 0.684318 | 0.230875 | 0.245000 | 0.167658 | 0.615666 | 0.500000 | 0.001650 |
PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | 0.651088 | 0.153623 | 0.200000 | 0.130218 | 0.409660 | 0.500000 | 0.002480 |
PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | 0.764724 | 0.206600 | 0.219000 | 0.167474 | 0.550933 | 0.500000 | 0.001844 |
PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | 0.685739 | 0.145850 | 0.200000 | 0.137148 | 0.388934 | 0.500000 | 0.002612 |
PERIMETER_MID_ZN_3 VAV BOX COMPONENT | 0.701394 | 0.225254 | 0.229000 | 0.160619 | 0.600677 | 0.500000 | 0.001691 |
PERIMETER_MID_ZN_2 VAV BOX COMPONENT | 0.699334 | 0.143024 | 0.200000 | 0.139867 | 0.381398 | 0.500000 | 0.002664 |
PERIMETER_MID_ZN_1 VAV BOX COMPONENT | 0.791071 | 0.199719 | 0.203000 | 0.160587 | 0.532583 | 0.500000 | 0.001908 |
PERIMETER_MID_ZN_4 VAV BOX COMPONENT | 0.745677 | 0.134127 | 0.200000 | 0.149135 | 0.357671 | 0.500000 | 0.002841 |
Design Size Nominal Capacity [W] | |
CORE_BOTTOM VAV BOX REHEAT COIL | 24100.66 |
CORE_MID VAV BOX REHEAT COIL | 23106.72 |
CORE_TOP VAV BOX REHEAT COIL | 29302.32 |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | 12586.62 |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | 8259.18 |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | 12629.82 |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | 8223.72 |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | 7884.40 |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | 5266.07 |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | 7939.44 |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | 5229.76 |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | 9349.74 |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | 6204.11 |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | 9391.00 |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | 6168.84 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PACU_VAV_BOT | 2.90 | 1.40 | 5.80 | 1.40 | 5.31 | 5.31 | 0.300000 | 0.263095 | 5.31 |
PACU_VAV_MID | 2.57 | 1.37 | 5.14 | 1.55 | 4.58 | 4.58 | 0.300000 | 0.337917 | 4.58 |
PACU_VAV_TOP | 2.88 | 1.47 | 5.76 | 2.34 | 5.50 | 5.50 | 0.300000 | 0.425838 | 5.50 |
Maximum Outdoor Air Flow Rate [m3/s] | |
PACU_VAV_BOT_OA_CONTROLLER | 5.31 |
PACU_VAV_MID_OA_CONTROLLER | 4.58 |
PACU_VAV_TOP_OA_CONTROLLER | 5.50 |
Design Size High Speed Rated Air Flow Rate [m3/s] | Design Size High Speed Gross Rated Total Cooling Capacity [W] | Design Size High Speed Rated Sensible Heat Ratio | Design Size Low Speed Rated Air Flow Rate [m3/s] | Design Size Low Speed Gross Rated Total Cooling Capacity [W] | Design Size Low Speed Gross Rated Sensible Heat Ratio | |
PACU_VAV_BOT COOLING COIL | 5.31 | 106278.64 | 0.776143 | 1.77 | 35422.67 | 0.776143 |
PACU_VAV_MID COOLING COIL | 4.58 | 94887.64 | 0.762684 | 1.53 | 31626.05 | 0.762684 |
PACU_VAV_TOP COOLING COIL | 5.50 | 109004.23 | 0.780022 | 1.83 | 36331.11 | 0.780022 |
Design Size Nominal Capacity [W] | |
PACU_VAV_BOT HEATING COIL | 12561.93 |
PACU_VAV_MID HEATING COIL | 14540.90 |
PACU_VAV_TOP HEATING COIL | 13322.17 |
Design Size Maximum Flow Rate [m3/s] | |
PACU_VAV_BOT FAN | 5.31 |
PACU_VAV_MID FAN | 4.58 |
PACU_VAV_TOP FAN | 5.50 |
Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
SWHSYS1 | 0.000054 | 0.006435 |
Design Flow Rate [m3/s] | Design Power Consumption [W] | |
SWHSYS1 PUMP | 0.000054 | 0.726125 |
Use Side Design Flow Rate [m3/s] | |
SWHSYS1 WATER HEATER | 0.000054 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
PERIMETER_TOP_ZN_3_WALL_NORTH | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | |
PERIMETER_TOP_ZN_2_WALL_EAST | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | |
PERIMETER_TOP_ZN_1_WALL_SOUTH | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | |
PERIMETER_TOP_ZN_4_WALL_WEST | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | |
PERIMETER_BOT_ZN_3_WALL_NORTH | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | |
PERIMETER_BOT_ZN_2_WALL_EAST | PERIMETER_BOT_ZN_2_WALL_EAST_DOOR | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | |
PERIMETER_BOT_ZN_1_WALL_SOUTH | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | |
PERIMETER_BOT_ZN_4_WALL_WEST | PERIMETER_BOT_ZN_4_WALL_WEST_DOOR | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | |
PERIMETER_MID_ZN_3_WALL_NORTH | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | |
PERIMETER_MID_ZN_2_WALL_EAST | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | |
PERIMETER_MID_ZN_1_WALL_SOUTH | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | |
PERIMETER_MID_ZN_4_WALL_WEST | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
VersionVersion ID | |
1 | 22.1 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 20.90 | 15.40 | 11.90 | 14.80 | 12.70 | 15.40 | 23.30 | 26.30 | 31.20 | 30.40 | 29.80 | 27.80 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | Tucson-Davis Monthan AFB AZ USA TMY3 WMO#=722745 | 32.17 | -110.88 | -7.00 | 809.00 | 91976 | 1.0932 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 21.66 | 19.30 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | OfficeMedium | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 18 | 167 | 24 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | CORE_BOTTOM | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 1.37 | 1 | 1 | 1 | 4.57 | 45.34 | 4.57 | 28.70 | 0.00 | 2.74 | 2.74 | 2698.04 | TARP | TARP | 983.54 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
2 | TOPFLOOR_PLENUM | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 11.28 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 33.27 | 10.67 | 11.89 | 1.22 | 2024.76 | TARP | TARP | 1660.73 | 202.84 | 202.84 | 0.00 | 10 | 0 | 0 | No |
3 | MIDFLOOR_PLENUM | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 7.32 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 33.27 | 6.71 | 7.92 | 1.22 | 2024.76 | TARP | TARP | 1660.73 | 202.84 | 202.84 | 0.00 | 14 | 0 | 0 | No |
4 | FIRSTFLOOR_PLENUM | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 3.35 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 33.27 | 2.74 | 3.96 | 1.22 | 2024.76 | TARP | TARP | 1660.73 | 202.84 | 202.84 | 0.00 | 14 | 0 | 0 | No |
5 | CORE_MID | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 5.33 | 1 | 1 | 1 | 4.57 | 45.34 | 4.57 | 28.70 | 3.96 | 6.71 | 2.74 | 2698.04 | TARP | TARP | 983.54 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
6 | CORE_TOP | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 9.30 | 1 | 1 | 1 | 4.57 | 45.34 | 4.57 | 28.70 | 7.92 | 10.67 | 2.74 | 2698.04 | TARP | TARP | 983.54 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
7 | PERIMETER_TOP_ZN_3 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 31.11 | 9.30 | 1 | 1 | 1 | 0.00 | 49.91 | 28.70 | 33.27 | 7.92 | 10.67 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 77.59 | 59.33 | 6 | 1 | 0 | Yes |
8 | PERIMETER_TOP_ZN_2 | 0.0 | 0.00 | 0.00 | 0.00 | 47.82 | 16.64 | 9.30 | 1 | 1 | 1 | 45.34 | 49.91 | 0.00 | 33.27 | 7.92 | 10.67 | 2.74 | 360.08 | TARP | TARP | 131.26 | 91.28 | 51.72 | 39.55 | 6 | 1 | 0 | Yes |
9 | PERIMETER_TOP_ZN_1 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 2.16 | 9.30 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 4.57 | 7.92 | 10.67 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 77.59 | 59.33 | 6 | 1 | 0 | Yes |
10 | PERIMETER_TOP_ZN_4 | 0.0 | 0.00 | 0.00 | 0.00 | 2.09 | 16.64 | 9.30 | 1 | 1 | 1 | 0.00 | 4.57 | 0.00 | 33.27 | 7.92 | 10.67 | 2.74 | 360.05 | TARP | TARP | 131.25 | 91.28 | 51.72 | 39.55 | 6 | 1 | 0 | Yes |
11 | PERIMETER_BOT_ZN_3 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 31.11 | 1.37 | 1 | 1 | 1 | 0.00 | 49.91 | 28.70 | 33.27 | 0.00 | 2.74 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 73.69 | 59.33 | 6 | 5 | 0 | Yes |
12 | PERIMETER_BOT_ZN_2 | 0.0 | 0.00 | 0.00 | 0.00 | 47.82 | 16.64 | 1.37 | 1 | 1 | 1 | 45.34 | 49.91 | 0.00 | 33.27 | 0.00 | 2.74 | 2.74 | 360.08 | TARP | TARP | 131.26 | 91.28 | 49.77 | 39.55 | 6 | 3 | 0 | Yes |
13 | PERIMETER_BOT_ZN_1 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 2.16 | 1.37 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 4.57 | 0.00 | 2.74 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 73.69 | 59.33 | 6 | 5 | 0 | Yes |
14 | PERIMETER_BOT_ZN_4 | 0.0 | 0.00 | 0.00 | 0.00 | 2.09 | 16.64 | 1.37 | 1 | 1 | 1 | 0.00 | 4.57 | 0.00 | 33.27 | 0.00 | 2.74 | 2.74 | 360.05 | TARP | TARP | 131.25 | 91.28 | 49.77 | 39.55 | 6 | 3 | 0 | Yes |
15 | PERIMETER_MID_ZN_3 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 31.11 | 5.33 | 1 | 1 | 1 | 0.00 | 49.91 | 28.70 | 33.27 | 3.96 | 6.71 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 77.59 | 59.33 | 6 | 1 | 0 | Yes |
16 | PERIMETER_MID_ZN_2 | 0.0 | 0.00 | 0.00 | 0.00 | 47.82 | 16.64 | 5.33 | 1 | 1 | 1 | 45.34 | 49.91 | 0.00 | 33.27 | 3.96 | 6.71 | 2.74 | 360.08 | TARP | TARP | 131.26 | 91.28 | 51.72 | 39.55 | 6 | 1 | 0 | Yes |
17 | PERIMETER_MID_ZN_1 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 2.16 | 5.33 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 4.57 | 3.96 | 6.71 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 77.59 | 59.33 | 6 | 1 | 0 | Yes |
18 | PERIMETER_MID_ZN_4 | 0.0 | 0.00 | 0.00 | 0.00 | 2.09 | 16.64 | 5.33 | 1 | 1 | 1 | 0.00 | 4.57 | 0.00 | 33.27 | 3.96 | 6.71 | 2.74 | 360.05 | TARP | TARP | 131.25 | 91.28 | 51.72 | 39.55 | 6 | 1 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | CORE_BOTTOM | 983.54 | 52.9 | 18.579 | 5.382E-002 | 5.932 | 24.834 | 0.000 | 0.000 | 0.000 | 0.000 | 30.766 | No |
2 | TOPFLOOR_PLENUM | 1660.73 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
3 | MIDFLOOR_PLENUM | 1660.73 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
4 | FIRSTFLOOR_PLENUM | 1660.73 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
5 | CORE_MID | 983.54 | 52.9 | 18.579 | 5.382E-002 | 5.932 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
6 | CORE_TOP | 983.54 | 52.9 | 18.579 | 5.382E-002 | 5.932 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
7 | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 5.932 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
8 | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 18.579 | 5.382E-002 | 5.932 | 8.069 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
9 | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 5.932 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
10 | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 18.579 | 5.382E-002 | 5.932 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
11 | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 5.932 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
12 | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 18.579 | 5.382E-002 | 5.932 | 8.069 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
13 | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 5.932 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
14 | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 18.579 | 5.382E-002 | 5.932 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
15 | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 5.932 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
16 | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 18.579 | 5.382E-002 | 5.932 | 8.069 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
17 | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 5.932 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
18 | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 18.579 | 5.382E-002 | 5.932 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.002 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | Cooling Effect Calculation | Ankle Draft Calculation | |
1 | CORE_BOTTOM | BLDG_OCC_SCH_WO_SB | CORE_BOTTOM | 983.54 | 52.9 | 52.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 53 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
2 | CORE_MID | BLDG_OCC_SCH_WO_SB | CORE_MID | 983.54 | 52.9 | 52.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 53 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
3 | CORE_TOP | BLDG_OCC_SCH_WO_SB | CORE_TOP | 983.54 | 52.9 | 52.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 53 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
4 | PERIMETER_TOP_ZN_3 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
5 | PERIMETER_TOP_ZN_2 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
6 | PERIMETER_TOP_ZN_1 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
7 | PERIMETER_TOP_ZN_4 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
8 | PERIMETER_BOT_ZN_3 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
9 | PERIMETER_BOT_ZN_2 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
10 | PERIMETER_BOT_ZN_1 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
11 | PERIMETER_BOT_ZN_4 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
12 | PERIMETER_MID_ZN_3 | BLDG_OCC_SCH_WO_SB | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
13 | PERIMETER_MID_ZN_2 | BLDG_OCC_SCH_W_SB | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
14 | PERIMETER_MID_ZN_1 | BLDG_OCC_SCH_WO_SB | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
15 | PERIMETER_MID_ZN_4 | BLDG_OCC_SCH_WO_SB | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | CORE_BOTTOM_LIGHTS | LTG_SCH_OFFICE | CORE_BOTTOM | 983.54 | 52.9 | 5834.488 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 5834.488 |
2 | CORE_MID_LIGHTS | LTG_SCH_OFFICE | CORE_MID | 983.54 | 52.9 | 5834.488 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 5834.488 |
3 | CORE_TOP_LIGHTS | LTG_SCH_OFFICE | CORE_TOP | 983.54 | 52.9 | 5834.488 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 5834.488 |
4 | PERIMETER_TOP_ZN_3_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 1229.961 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1229.961 |
5 | PERIMETER_TOP_ZN_2_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 778.667 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 778.667 |
6 | PERIMETER_TOP_ZN_1_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 1229.961 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1229.961 |
7 | PERIMETER_TOP_ZN_4_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 778.616 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 778.616 |
8 | PERIMETER_BOT_ZN_3_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 1229.961 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1229.961 |
9 | PERIMETER_BOT_ZN_2_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 778.667 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 778.667 |
10 | PERIMETER_BOT_ZN_1_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 1229.961 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1229.961 |
11 | PERIMETER_BOT_ZN_4_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 778.616 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 778.616 |
12 | PERIMETER_MID_ZN_3_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 1229.961 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1229.961 |
13 | PERIMETER_MID_ZN_2_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 778.667 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 778.667 |
14 | PERIMETER_MID_ZN_1_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 1229.961 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1229.961 |
15 | PERIMETER_MID_ZN_4_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 778.616 | 5.932 | 110.212 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 778.616 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | CORE_BOTTOM_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_BOTTOM | 983.54 | 52.9 | 7937.156 | 8.070 | 149.931 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 7937.156 |
2 | CORE_MID_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_MID | 983.54 | 52.9 | 7937.156 | 8.070 | 149.931 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 7937.156 |
3 | CORE_TOP_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_TOP | 983.54 | 52.9 | 7937.156 | 8.070 | 149.931 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 7937.156 |
4 | PERIMETER_TOP_ZN_3_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 1673.214 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.214 |
5 | PERIMETER_TOP_ZN_2_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 1059.217 | 8.069 | 149.921 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.217 |
6 | PERIMETER_TOP_ZN_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 1673.203 | 8.070 | 149.929 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.203 |
7 | PERIMETER_TOP_ZN_4_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 1059.210 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.210 |
8 | PERIMETER_BOT_ZN_3_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 1673.214 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.214 |
9 | PERIMETER_BOT_ZN_2_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 1059.217 | 8.069 | 149.921 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.217 |
10 | PERIMETER_BOT_ZN_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 1673.203 | 8.070 | 149.929 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.203 |
11 | PERIMETER_BOT_ZN_4_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 1059.210 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.210 |
12 | PERIMETER_MID_ZN_3_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 1673.214 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.214 |
13 | PERIMETER_MID_ZN_2_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 1059.217 | 8.069 | 149.921 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.217 |
14 | PERIMETER_MID_ZN_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 1673.203 | 8.070 | 149.929 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.203 |
15 | PERIMETER_MID_ZN_4_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 1059.210 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.210 |
16 | CORE_BOTTOM_ELEVATORS_EQUIP | BLDG_ELEVATORS | CORE_BOTTOM | 983.54 | 52.9 | 16363.220 | 16.637 | 309.098 | 0.000 | 0.500 | 0.000 | 0.500 | ElevatorLift | 1963.586 | 11290.622 |
17 | ELEVATORS_LIGHTS_FAN | ELEV_LIGHT_FAN_SCH_ADD_DF | CORE_BOTTOM | 983.54 | 52.9 | 125.000 | 0.127 | 2.361 | 0.000 | 0.500 | 0.000 | 0.500 | ElevatorLightsFan | 0.000 | 86.250 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 2.101 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | INTERIORFURNISHINGS | 2 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
3 | DROPCEILING | 4 | 1 | 3 | 0.167 | 4.488 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
4 | INT_WALL | 7 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | INT_SLAB_FLOOR | 12 | 2 | 7 | 0.167 | 3.839 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
6 | INT_SLAB_CEILING | 13 | 2 | 7 | 0.167 | 3.839 | 0.900 | 0.900 | 0.700 | 0.700 | VeryRough |
7 | NONRES_ROOF | 17 | 3 | 3 | 0.167 | 0.2284 | 0.750 | 0.900 | 0.450 | 0.700 | Rough |
8 | NONRES_EXT_WALL_GRD | 20 | 4 | 7 | 0.167 | 1.029 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
9 | NONRES_EXT_WALL_MID | 21 | 4 | 7 | 0.167 | 1.013 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
10 | NONRES_EXT_WALL_TOP | 22 | 4 | 6 | 0.167 | 1.375 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
11 | PERIMETER_BOT_ZN_1_FLOOR_FFACTOR | 39 | 2 | 7 | 0.167 | 0.3192 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
12 | PERIMETER_BOT_ZN_2_FLOOR_FFACTOR | 40 | 2 | 7 | 0.167 | 0.3371 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
13 | PERIMETER_BOT_ZN_3_FLOOR_FFACTOR | 41 | 2 | 7 | 0.167 | 0.3192 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
14 | PERIMETER_BOT_ZN_4_FLOOR_FFACTOR | 42 | 2 | 7 | 0.167 | 0.3371 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
15 | CORE_BOT_ZN_5_FLOOR_FFACTOR | 43 | 2 | 8 | 0.167 | 0.5650E-02 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.4760 |
2 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
3 | AC02 ACOUSTIC CEILING | 0.0127 | 0.057 | 288.000 | 1339.000 | 0.2228 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
6 | 100MM NORMALWEIGHT CONCRETE FLOOR | 0.1016 | 2.310 | 2322.000 | 832.000 | 0.4398E-01 |
7 | CP02 CARPET PAD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2165 |
8 | CP02 CARPET PAD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2165 |
9 | 100MM NORMALWEIGHT CONCRETE FLOOR | 0.1016 | 2.310 | 2322.000 | 832.000 | 0.4398E-01 |
10 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
11 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 4.319 |
12 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
13 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
14 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
15 | NONRES_EXTERIOR_WALL_INSULATION_GRD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.7377 |
16 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
17 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
18 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
19 | NONRES_EXTERIOR_WALL_INSULATION_MID | 0.0000 | 0.000 | 0.000 | 0.000 | 0.7531 |
20 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
21 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
22 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
23 | NONRES_EXTERIOR_WALL_INSULATION_TOP | 0.0000 | 0.000 | 0.000 | 0.000 | 0.4931 |
24 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
25 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.056 |
26 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
27 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 2.890 |
28 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
29 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.056 |
30 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
31 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 2.890 |
32 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
33 | ~FC_Insulation_5 | 0.0000 | 0.000 | 0.000 | 0.000 | 176.9 |
34 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 2.1009573 | 2.1009573 | 2.1009573 | |
3 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
4 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
5 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
6 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
7 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
8 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
9 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
10 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
11 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
12 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
13 | 3 | -0.21589802E-09 | 0.15643069E-09 | -0.21589802E-09 | 0.12999471E-21 |
14 | 2 | 0.50772448E-02 | 0.30006816E-02 | 0.50772448E-02 | -0.13693132E-08 |
15 | 1 | -2.5944910 | 1.4597758 | -2.5944910 | 0.76344767E-02 |
16 | 0 | 7.0433378 | 2.9911476 | 7.0433378 | |
17 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
18 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
19 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
20 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
21 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
22 | 7 | 0.43260499E-16 | 0.34524919E-16 | 0.52793240E-17 | 0.0000000 |
23 | 6 | 0.69434179E-09 | 0.98085174E-11 | 0.18162501E-10 | -0.40870994E-12 |
24 | 5 | -0.12888762E-04 | 0.28373718E-06 | -0.16918523E-06 | 0.92361873E-08 |
25 | 4 | 0.25174112E-01 | 0.33697681E-03 | 0.22646198E-03 | -0.31467795E-04 |
26 | 3 | -3.7600775 | 0.27170599E-01 | -0.48495626E-01 | 0.94171705E-02 |
27 | 2 | 51.553741 | 0.22121684 | 1.2284947 | -0.25833933 |
28 | 1 | -128.86110 | 0.21944682 | -5.1479470 | 1.1228340 |
29 | 0 | 81.526494 | 0.16043334E-01 | 4.4519351 | |
30 | 7 | 0.52793240E-17 | 0.34524919E-16 | 0.43260499E-16 | 0.0000000 |
31 | 6 | 0.18162501E-10 | 0.98085174E-11 | 0.69434179E-09 | -0.40870994E-12 |
32 | 5 | -0.16918523E-06 | 0.28373718E-06 | -0.12888762E-04 | 0.92361873E-08 |
33 | 4 | 0.22646198E-03 | 0.33697681E-03 | 0.25174112E-01 | -0.31467795E-04 |
34 | 3 | -0.48495626E-01 | 0.27170599E-01 | -3.7600775 | 0.94171705E-02 |
35 | 2 | 1.2284947 | 0.22121684 | 51.553741 | -0.25833933 |
36 | 1 | -5.1479470 | 0.21944682 | -128.86110 | 1.1228340 |
37 | 0 | 4.4519351 | 0.16043334E-01 | 81.526494 | |
38 | 3 | -0.62451068E-06 | 0.10350887E-08 | -0.38276125E-05 | 0.11995084E-16 |
39 | 2 | 0.77976586 | 0.13989883E-02 | 1.0579789 | -0.73382352E-06 |
40 | 1 | -21.958702 | 0.93426804E-01 | -6.3215779 | 0.20283230 |
41 | 0 | 21.361010 | 0.87247630E-01 | 5.4456762 | |
42 | 7 | -0.27613173E-12 | 0.13648587E-14 | -0.80406974E-13 | 0.78369587E-16 |
43 | 6 | 0.25651297E-07 | 0.27955499E-09 | 0.59014154E-08 | -0.11905989E-12 |
44 | 5 | -0.17465063E-03 | 0.24416492E-05 | -0.90019538E-04 | 0.58421144E-08 |
45 | 4 | 0.27387862 | 0.12098825E-02 | 0.93122264E-01 | -0.31012301E-04 |
46 | 3 | -6.9041115 | 0.38080793E-01 | -2.2314619 | 0.27235146E-01 |
47 | 2 | 39.676056 | 0.13726811 | 14.823303 | -0.32003278 |
48 | 1 | -79.629469 | 0.62686726E-01 | -28.745292 | 1.0590931 |
49 | 0 | 46.824345 | 0.12759187E-02 | 16.300942 | |
50 | 7 | -0.27182421E-12 | 0.13107754E-14 | -0.81108189E-13 | 0.79120162E-16 |
51 | 6 | 0.25844325E-07 | 0.27588229E-09 | 0.59440225E-08 | -0.12008605E-12 |
52 | 5 | -0.17564658E-03 | 0.24062150E-05 | -0.90521036E-04 | 0.58837691E-08 |
53 | 4 | 0.27506755 | 0.11908598E-02 | 0.93548701E-01 | -0.31177608E-04 |
54 | 3 | -6.9277136 | 0.37441415E-01 | -2.2384615 | 0.27350651E-01 |
55 | 2 | 39.753961 | 0.13483533 | 14.852153 | -0.32090009 |
56 | 1 | -79.689237 | 0.61525268E-01 | -28.771196 | 1.0603666 |
57 | 0 | 46.824344 | 0.12512697E-02 | 16.300293 | |
58 | 6 | 0.21465343E-07 | 0.35044740E-09 | 0.49771822E-08 | -0.96989815E-13 |
59 | 5 | -0.15274237E-03 | 0.31655188E-05 | -0.78941554E-04 | 0.49363227E-08 |
60 | 4 | 0.24727258 | 0.16154212E-02 | 0.83601931E-01 | -0.27359285E-04 |
61 | 3 | -6.3748395 | 0.52179222E-01 | -2.0745682 | 0.24648141E-01 |
62 | 2 | 37.927790 | 0.19236366 | 14.173893 | -0.30057625 |
63 | 1 | -78.286849 | 0.89555956E-01 | -28.161423 | 1.0304865 |
64 | 0 | 46.824354 | 0.18576719E-02 | 16.316151 | |
65 | 7 | -0.13059908E-08 | -0.16504735E-15 | 0.90649122E-14 | -0.12541312E-15 |
66 | 6 | 0.89164571E-05 | 0.61445766E-08 | 0.31804070E-02 | -0.26679919E-04 |
67 | 5 | -0.64531733E-03 | 0.36428408E-05 | -0.22318667 | 0.19514025E-02 |
68 | 4 | 0.14868215E-01 | 0.16589759E-03 | 4.8205855 | -0.45178851E-01 |
69 | 3 | -0.13063200 | 0.13198961E-02 | -37.970795 | 0.39809422 |
70 | 2 | 0.46393162 | 0.21965806E-02 | 116.38542 | -1.4166214 |
71 | 1 | -0.66966470 | 0.66967549E-03 | -143.84930 | 2.0480865 |
72 | 0 | 0.32650513 | 0.16166393E-04 | 60.838472 | |
73 | 7 | -0.12346633E-08 | -0.14425327E-15 | 0.91357699E-14 | -0.10087110E-15 |
74 | 6 | 0.94177090E-05 | 0.64929528E-08 | 0.31789869E-02 | -0.26668006E-04 |
75 | 5 | -0.68205191E-03 | 0.38502154E-05 | -0.22310594 | 0.19506899E-02 |
76 | 4 | 0.15716902E-01 | 0.17535208E-03 | 4.8192406 | -0.45165923E-01 |
77 | 3 | -0.13809356 | 0.13952366E-02 | -37.963195 | 0.39801023 |
78 | 2 | 0.49043520 | 0.23220647E-02 | 116.37063 | -1.4164235 |
79 | 1 | -0.70792287 | 0.70803996E-03 | -143.84059 | 2.0479434 |
80 | 0 | 0.34515858 | 0.17069463E-04 | 60.838472 | |
81 | 7 | -0.13059908E-08 | -0.16504702E-15 | 0.90649122E-14 | -0.12541312E-15 |
82 | 6 | 0.89164571E-05 | 0.61445766E-08 | 0.31804070E-02 | -0.26679919E-04 |
83 | 5 | -0.64531733E-03 | 0.36428408E-05 | -0.22318667 | 0.19514025E-02 |
84 | 4 | 0.14868215E-01 | 0.16589759E-03 | 4.8205855 | -0.45178851E-01 |
85 | 3 | -0.13063200 | 0.13198961E-02 | -37.970795 | 0.39809422 |
86 | 2 | 0.46393162 | 0.21965806E-02 | 116.38542 | -1.4166214 |
87 | 1 | -0.66966470 | 0.66967549E-03 | -143.84930 | 2.0480865 |
88 | 0 | 0.32650513 | 0.16166393E-04 | 60.838472 | |
89 | 7 | -0.12345751E-08 | -0.14398051E-15 | 0.92894684E-14 | -0.10085648E-15 |
90 | 6 | 0.94183649E-05 | 0.64934092E-08 | 0.31789851E-02 | -0.26667991E-04 |
91 | 5 | -0.68209995E-03 | 0.38504865E-05 | -0.22310583 | 0.19506890E-02 |
92 | 4 | 0.15718012E-01 | 0.17536444E-03 | 4.8192388 | -0.45165906E-01 |
93 | 3 | -0.13810332 | 0.13953351E-02 | -37.963185 | 0.39801012 |
94 | 2 | 0.49046985 | 0.23222288E-02 | 116.37061 | -1.4164232 |
95 | 1 | -0.70797289 | 0.70809005E-03 | -143.84058 | 2.0479432 |
96 | 0 | 0.34518296 | 0.17070678E-04 | 60.838472 | |
97 | 8 | 0.57026216E-10 | -0.29656739E-13 | 0.26072253E-13 | -0.16907584E-15 |
98 | 7 | -0.80728763E-07 | 0.14958947E-11 | -0.10196182E-04 | 0.85534123E-07 |
99 | 6 | 0.59163330E-05 | 0.23390251E-08 | 0.39199948E-02 | -0.33137873E-04 |
100 | 5 | -0.14678961E-03 | 0.29443049E-06 | -0.24001665 | 0.21083805E-02 |
101 | 4 | 0.15257864E-02 | 0.63469284E-05 | 4.9653291 | -0.46676227E-01 |
102 | 3 | -0.74362311E-02 | 0.30151767E-04 | -38.474208 | 0.40407555 |
103 | 2 | 0.17883035E-01 | 0.32406056E-04 | 117.10039 | -1.4265819 |
104 | 1 | -0.20235698E-01 | 0.62001922E-05 | -144.19380 | 2.0537490 |
105 | 0 | 0.84795330E-02 | 0.69040512E-07 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | Conductance (Before Adjusted) {W/m2-K} | Convection Coefficient Adjustment Ratio | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | WINDOW_U_0.4547_SHGC_EAST_0.25 | 35 | 1 | VerySmooth | 2.584 | 2.584 | 1.000 | 0.251 | ||
2 | WINDOW_U_0.4547_SHGC_SOUTH_0.25 | 36 | 1 | VerySmooth | 2.584 | 2.584 | 1.000 | 0.251 | ||
3 | WINDOW_U_0.4547_SHGC_WEST_0.25 | 37 | 1 | VerySmooth | 2.584 | 2.584 | 1.000 | 0.251 | ||
4 | WINDOW_U_0.4547_SHGC_NORTH_0.25 | 38 | 1 | VerySmooth | 2.584 | 2.584 | 1.000 | 0.251 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | GLAZING LAYER EAST | SpectralAverage | 2.60743E-002 | 0.16139 | 0.61671 | 0.61671 | 0.25000 | 0.16143 | 0.23877 | 0.00000 | 0.84000 | 0.84000 | 0.12075 | 1.00000 | No | |
2 | GLAZING LAYER SOUTH | SpectralAverage | 2.60743E-002 | 0.16139 | 0.61671 | 0.61671 | 0.25000 | 0.16143 | 0.23877 | 0.00000 | 0.84000 | 0.84000 | 0.12075 | 1.00000 | No | |
3 | GLAZING LAYER WEST | SpectralAverage | 2.60743E-002 | 0.16139 | 0.61671 | 0.61671 | 0.25000 | 0.16143 | 0.23877 | 0.00000 | 0.84000 | 0.84000 | 0.12075 | 1.00000 | No | |
4 | GLAZING LAYER NORTH | SpectralAverage | 2.60743E-002 | 0.16139 | 0.61671 | 0.61671 | 0.25000 | 0.16143 | 0.23877 | 0.00000 | 0.84000 | 0.84000 | 0.12075 | 1.00000 | No |
Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | PolygonClipping | Periodic | 30 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
Enclosure Name | Number of Exterior Windows | Number of Exterior Windows in Adjacent Enclosures | |
1 | PERIMETER_TOP_ZN_3 | 1 | 0 |
2 | PERIMETER_TOP_ZN_2 | 1 | 0 |
3 | PERIMETER_TOP_ZN_1 | 1 | 0 |
4 | PERIMETER_TOP_ZN_4 | 1 | 0 |
5 | PERIMETER_BOT_ZN_3 | 3 | 0 |
6 | PERIMETER_BOT_ZN_2 | 2 | 0 |
7 | PERIMETER_BOT_ZN_1 | 3 | 0 |
8 | PERIMETER_BOT_ZN_4 | 2 | 0 |
9 | PERIMETER_MID_ZN_3 | 1 | 0 |
10 | PERIMETER_MID_ZN_2 | 1 | 0 |
11 | PERIMETER_MID_ZN_1 | 1 | 0 |
12 | PERIMETER_MID_ZN_4 | 1 | 0 |
Enclosure Name | Number of Adjacent Enclosures with Windows | Adjacent Enclosure Names - 1st 100 (max) | |
1 | PERIMETER_TOP_ZN_3 | 0 | |
2 | PERIMETER_TOP_ZN_2 | 0 | |
3 | PERIMETER_TOP_ZN_1 | 0 | |
4 | PERIMETER_TOP_ZN_4 | 0 | |
5 | PERIMETER_BOT_ZN_3 | 0 | |
6 | PERIMETER_BOT_ZN_2 | 0 | |
7 | PERIMETER_BOT_ZN_1 | 0 | |
8 | PERIMETER_BOT_ZN_4 | 0 | |
9 | PERIMETER_MID_ZN_3 | 0 | |
10 | PERIMETER_MID_ZN_2 | 0 | |
11 | PERIMETER_MID_ZN_1 | 0 | |
12 | PERIMETER_MID_ZN_4 | 0 |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | 0.3785 | 29307.1 | 1.024 | 0.2440 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | CORE_BOT_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
2 | CORE_BOT_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
3 | CORE_BOT_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
4 | CORE_BOT_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
5 | CORE_BOT_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
6 | CORE_BOT_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
7 | CORE_BOTTOM_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
8 | PERIMETER_TOP_PLENUM_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
9 | PERIMETER_TOP_PLENUM_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
10 | PERIMETER_TOP_PLENUM_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
11 | PERIMETER_TOP_PLENUM_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
12 | iz-PERIMETER_TOP_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
13 | iz-PERIMETER_TOP_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
14 | iz-PERIMETER_TOP_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
15 | iz-PERIMETER_TOP_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
16 | iz-CORE_TOP_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
17 | BUILDING_ROOF | 0 | 1660.73 | 183.01 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
18 | PERIMETER_MID_PLENUM_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
19 | PERIMETER_MID_PLENUM_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
20 | PERIMETER_MID_PLENUM_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
21 | PERIMETER_MID_PLENUM_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
22 | iz-PERIMETER_MID_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
23 | iz-PERIMETER_MID_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
24 | iz-PERIMETER_MID_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
25 | iz-PERIMETER_MID_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
26 | iz-CORE_MID_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
27 | iz-PERIMETER_TOP_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
28 | iz-PERIMETER_TOP_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
29 | iz-PERIMETER_TOP_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
30 | iz-PERIMETER_TOP_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
31 | iz-CORE_TOP_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
32 | PERIMETER_BOT_PLENUM_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
33 | PERIMETER_BOT_PLENUM_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
34 | PERIMETER_BOT_PLENUM_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
35 | PERIMETER_BOT_PLENUM_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
36 | iz-PERIMETER_BOT_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
37 | iz-PERIMETER_BOT_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
38 | iz-PERIMETER_BOT_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
39 | iz-PERIMETER_BOT_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
40 | iz-CORE_BOT_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
41 | iz-PERIMETER_MID_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
42 | iz-PERIMETER_MID_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
43 | iz-PERIMETER_MID_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
44 | iz-PERIMETER_MID_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
45 | iz-CORE_MID_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
46 | CORE_MID_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
47 | CORE_MID_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
48 | CORE_MID_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
49 | CORE_MID_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
50 | CORE_MID_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
51 | CORE_MID_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
52 | CORE_MID_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
53 | CORE_TOP_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
54 | CORE_TOP_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
55 | CORE_TOP_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
56 | CORE_TOP_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
57 | CORE_TOP_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
58 | CORE_TOP_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
59 | CORE_TOP_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
60 | PERIMETER_TOP_ZN_3_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 3 | No | No |
61 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
62 | PERIMETER_TOP_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
63 | iz-PERIMETER_TOP_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
64 | iz-CORE_TOP_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
65 | PERIMETER_TOP_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
66 | PERIMETER_TOP_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
67 | PERIMETER_TOP_ZN_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
68 | PERIMETER_TOP_ZN_2_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 3 | No | No |
69 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 2 | No | No |
70 | PERIMETER_TOP_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
71 | iz-PERIMETER_TOP_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
72 | iz-CORE_TOP_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
73 | PERIMETER_TOP_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
74 | PERIMETER_TOP_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
75 | PERIMETER_TOP_ZN_2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
76 | PERIMETER_TOP_ZN_1_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 3 | No | No |
77 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
78 | PERIMETER_TOP_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
79 | iz-PERIMETER_TOP_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
80 | iz-CORE_TOP_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
81 | PERIMETER_TOP_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
82 | PERIMETER_TOP_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
83 | PERIMETER_TOP_ZN_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
84 | PERIMETER_TOP_ZN_4_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 3 | No | No |
85 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 2 | No | No |
86 | PERIMETER_TOP_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
87 | iz-PERIMETER_TOP_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
88 | iz-CORE_TOP_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
89 | PERIMETER_TOP_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
90 | PERIMETER_TOP_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
91 | PERIMETER_TOP_ZN_4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
92 | PERIMETER_BOT_ZN_3_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 3 | No | No |
93 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
94 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
95 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
96 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
97 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
98 | PERIMETER_BOT_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
99 | iz-PERIMETER_BOT_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
100 | iz-CORE_BOT_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
101 | PERIMETER_BOT_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
102 | PERIMETER_BOT_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
103 | PERIMETER_BOT_ZN_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
104 | PERIMETER_BOT_ZN_2_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 3 | No | No |
105 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 2 | No | No |
106 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 2 | No | No |
107 | PERIMETER_BOT_ZN_2_WALL_EAST_DOOR | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
108 | PERIMETER_BOT_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
109 | iz-PERIMETER_BOT_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
110 | iz-CORE_BOT_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
111 | PERIMETER_BOT_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
112 | PERIMETER_BOT_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
113 | PERIMETER_BOT_ZN_2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
114 | PERIMETER_BOT_ZN_1_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 3 | No | No |
115 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
116 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
117 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
118 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
119 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
120 | PERIMETER_BOT_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
121 | iz-PERIMETER_BOT_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
122 | iz-CORE_BOT_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
123 | PERIMETER_BOT_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
124 | PERIMETER_BOT_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
125 | PERIMETER_BOT_ZN_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
126 | PERIMETER_BOT_ZN_4_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 3 | No | No |
127 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 2 | No | No |
128 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 2 | No | No |
129 | PERIMETER_BOT_ZN_4_WALL_WEST_DOOR | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
130 | PERIMETER_BOT_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
131 | iz-PERIMETER_BOT_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
132 | iz-CORE_BOT_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
133 | PERIMETER_BOT_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
134 | PERIMETER_BOT_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
135 | PERIMETER_BOT_ZN_4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
136 | PERIMETER_MID_ZN_3_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 3 | No | No |
137 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
138 | PERIMETER_MID_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
139 | iz-PERIMETER_MID_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
140 | iz-CORE_MID_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
141 | PERIMETER_MID_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
142 | PERIMETER_MID_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
143 | PERIMETER_MID_ZN_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
144 | PERIMETER_MID_ZN_2_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 3 | No | No |
145 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 2 | No | No |
146 | PERIMETER_MID_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
147 | iz-PERIMETER_MID_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
148 | iz-CORE_MID_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
149 | PERIMETER_MID_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
150 | PERIMETER_MID_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
151 | PERIMETER_MID_ZN_2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
152 | PERIMETER_MID_ZN_1_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 3 | No | No |
153 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 2 | No | No |
154 | PERIMETER_MID_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
155 | iz-PERIMETER_MID_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
156 | iz-CORE_MID_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
157 | PERIMETER_MID_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
158 | PERIMETER_MID_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
159 | PERIMETER_MID_ZN_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.43 | 0 | No | No |
160 | PERIMETER_MID_ZN_4_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 3 | No | No |
161 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 2 | No | No |
162 | PERIMETER_MID_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
163 | iz-PERIMETER_MID_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
164 | iz-CORE_MID_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
165 | PERIMETER_MID_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
166 | PERIMETER_MID_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
167 | PERIMETER_MID_ZN_4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.43 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | PERIMETER_TOP_ZN_3_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 1.950E-002 | 9.403E-005 | 1.424E-004 | 0.123 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | PERIMETER_TOP_ZN_2_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 1.300E-002 | 9.902E-005 | 1.424E-004 | 0.130 | 0.000 | 0.000 | 0.224 | 0.000 |
3 | PERIMETER_TOP_ZN_1_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 1.950E-002 | 9.403E-005 | 1.424E-004 | 0.123 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | PERIMETER_TOP_ZN_4_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 1.300E-002 | 9.902E-005 | 1.424E-004 | 0.130 | 0.000 | 0.000 | 0.224 | 0.000 |
5 | PERIMETER_BOT_ZN_3_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 1.950E-002 | 9.403E-005 | 1.384E-004 | 0.123 | 0.000 | 0.000 | 0.224 | 0.000 |
6 | PERIMETER_BOT_ZN_2_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 1.300E-002 | 9.902E-005 | 1.394E-004 | 0.130 | 0.000 | 0.000 | 0.224 | 0.000 |
7 | PERIMETER_BOT_ZN_1_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 1.950E-002 | 9.403E-005 | 1.384E-004 | 0.123 | 0.000 | 0.000 | 0.224 | 0.000 |
8 | PERIMETER_BOT_ZN_1_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 1.043 | 5.030E-003 | 7.407E-003 | 6.602 | 1.000 | 0.000 | 0.000 | 0.000 |
9 | PERIMETER_BOT_ZN_4_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 1.300E-002 | 9.902E-005 | 1.394E-004 | 0.130 | 0.000 | 0.000 | 0.224 | 0.000 |
10 | PERIMETER_MID_ZN_3_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 1.950E-002 | 9.403E-005 | 1.424E-004 | 0.123 | 0.000 | 0.000 | 0.224 | 0.000 |
11 | PERIMETER_MID_ZN_2_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 1.300E-002 | 9.902E-005 | 1.424E-004 | 0.130 | 0.000 | 0.000 | 0.224 | 0.000 |
12 | PERIMETER_MID_ZN_1_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 1.950E-002 | 9.403E-005 | 1.424E-004 | 0.123 | 0.000 | 0.000 | 0.224 | 0.000 |
13 | PERIMETER_MID_ZN_4_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 1.300E-002 | 9.902E-005 | 1.424E-004 | 0.130 | 0.000 | 0.000 | 0.224 | 0.000 |
14 | FIRSTFLOOR_PLENUM_INFILTRATION | INFIL_SCH_PNNL | FIRSTFLOOR_PLENUM | 1660.73 | 0.0 | 2.888E-002 | 1.739E-005 | 1.424E-004 | 5.135E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
15 | MIDFLOOR_PLENUM_INFILTRATION | INFIL_SCH_PNNL | MIDFLOOR_PLENUM | 1660.73 | 0.0 | 2.888E-002 | 1.739E-005 | 1.424E-004 | 5.135E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
16 | TOPFLOOR_PLENUM_INFILTRATION | INFIL_SCH_PNNL | TOPFLOOR_PLENUM | 1660.73 | 0.0 | 2.888E-002 | 1.739E-005 | 1.550E-005 | 5.135E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | CORE_BOTTOM | Mixing/Well-Stirred |
2 | TOPFLOOR_PLENUM | Mixing/Well-Stirred |
3 | MIDFLOOR_PLENUM | Mixing/Well-Stirred |
4 | FIRSTFLOOR_PLENUM | Mixing/Well-Stirred |
5 | CORE_MID | Mixing/Well-Stirred |
6 | CORE_TOP | Mixing/Well-Stirred |
7 | PERIMETER_TOP_ZN_3 | Mixing/Well-Stirred |
8 | PERIMETER_TOP_ZN_2 | Mixing/Well-Stirred |
9 | PERIMETER_TOP_ZN_1 | Mixing/Well-Stirred |
10 | PERIMETER_TOP_ZN_4 | Mixing/Well-Stirred |
11 | PERIMETER_BOT_ZN_3 | Mixing/Well-Stirred |
12 | PERIMETER_BOT_ZN_2 | Mixing/Well-Stirred |
13 | PERIMETER_BOT_ZN_1 | Mixing/Well-Stirred |
14 | PERIMETER_BOT_ZN_4 | Mixing/Well-Stirred |
15 | PERIMETER_MID_ZN_3 | Mixing/Well-Stirred |
16 | PERIMETER_MID_ZN_2 | Mixing/Well-Stirred |
17 | PERIMETER_MID_ZN_1 | Mixing/Well-Stirred |
18 | PERIMETER_MID_ZN_4 | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.0000 |
Sizing Factor ID | Value | |
1 | Global | 1.0000 |
Sky Type | MonthAndDay | Daylighting Control Name | Enclosure Name | Window Name | Reference Point | Daylight Factor | |
1 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 6.0300E-003 |
2 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 6.0672E-003 |
3 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 6.5097E-003 |
4 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 6.5412E-003 |
5 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 4.5103E-003 |
6 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 4.5358E-003 |
7 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 2.4264E-003 |
8 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 2.4410E-003 |
9 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 8.9944E-002 |
10 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 4.2257E-002 |
11 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 0.1011 |
12 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 4.6293E-002 |
13 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 6.7991E-002 |
14 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 2.7505E-002 |
15 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 2.8057E-002 |
16 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 1.0496E-002 |
17 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 6.0308E-003 |
18 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 6.0732E-003 |
19 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 6.5106E-003 |
20 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 6.5478E-003 |
21 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 4.5113E-003 |
22 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 4.5405E-003 |
23 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 2.4263E-003 |
24 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 2.4409E-003 |
25 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 4.1213E-002 |
26 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 2.3839E-002 |
27 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 3.8855E-002 |
28 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 2.1941E-002 |
29 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 4.0855E-002 |
30 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 2.0372E-002 |
31 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 3.2668E-002 |
32 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 1.5265E-002 |
33 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 3.6898E-004 |
34 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 3.7043E-004 |
35 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 3.4933E-004 |
36 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 3.5038E-004 |
37 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 3.3533E-004 |
38 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 3.3570E-004 |
39 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 2.8320E-004 |
40 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 2.8371E-004 |
41 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.4614E-003 |
42 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.4945E-003 |
43 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.0698E-003 |
44 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.0962E-003 |
45 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 1.8086E-003 |
46 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.8278E-003 |
47 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.4263E-003 |
48 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.4409E-003 |
49 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.2862E-002 |
50 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.3351E-002 |
51 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 1.7739E-002 |
52 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.0215E-002 |
53 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 1.6935E-002 |
54 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 7.1840E-003 |
55 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.8057E-002 |
56 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.0496E-002 |
57 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.4612E-003 |
58 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.4944E-003 |
59 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.0694E-003 |
60 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.0953E-003 |
61 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 1.8077E-003 |
62 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.8245E-003 |
63 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 2.4264E-003 |
64 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.4410E-003 |
65 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 3.5603E-002 |
66 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 2.1226E-002 |
67 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 3.2001E-002 |
68 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 1.8742E-002 |
69 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 3.5760E-002 |
70 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 1.8037E-002 |
71 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 3.2668E-002 |
72 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 1.5265E-002 |
73 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 3.3441E-004 |
74 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 3.3792E-004 |
75 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 3.0680E-004 |
76 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 3.1048E-004 |
77 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 3.0535E-004 |
78 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 3.0704E-004 |
79 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 2.8321E-004 |
80 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 2.8372E-004 |
81 | Clear Sky | 12/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 8.9174E-002 |
82 | Clear Sky | 12/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 5.1272E-002 |
83 | Clear Turbid Sky | 12/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 9.8623E-002 |
84 | Clear Turbid Sky | 12/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 5.5983E-002 |
85 | Intermediate Sky | 12/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 7.1622E-002 |
86 | Intermediate Sky | 12/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 3.4618E-002 |
87 | Overcast Sky | 12/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 3.1564E-002 |
88 | Overcast Sky | 12/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 1.4627E-002 |
89 | Clear Sky | 12/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 3.9661E-002 |
90 | Clear Sky | 12/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 2.2968E-002 |
91 | Clear Turbid Sky | 12/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 3.7467E-002 |
92 | Clear Turbid Sky | 12/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 2.1165E-002 |
93 | Intermediate Sky | 12/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 3.9673E-002 |
94 | Intermediate Sky | 12/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 1.9729E-002 |
95 | Overcast Sky | 12/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 3.1886E-002 |
96 | Overcast Sky | 12/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 1.4843E-002 |
97 | Clear Sky | 12/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 2.6010E-002 |
98 | Clear Sky | 12/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 1.7357E-002 |
99 | Clear Turbid Sky | 12/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 2.0571E-002 |
100 | Clear Turbid Sky | 12/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 1.3690E-002 |
101 | Intermediate Sky | 12/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 1.9745E-002 |
102 | Intermediate Sky | 12/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 1.0394E-002 |
103 | Overcast Sky | 12/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 3.1564E-002 |
104 | Overcast Sky | 12/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 1.4627E-002 |
105 | Clear Sky | 12/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 3.4254E-002 |
106 | Clear Sky | 12/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 2.0485E-002 |
107 | Clear Turbid Sky | 12/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 3.0863E-002 |
108 | Clear Turbid Sky | 12/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 1.8127E-002 |
109 | Intermediate Sky | 12/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 3.4756E-002 |
110 | Intermediate Sky | 12/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 1.7503E-002 |
111 | Overcast Sky | 12/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 3.1887E-002 |
112 | Overcast Sky | 12/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 1.4843E-002 |
113 | Clear Sky | 12/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 8.9175E-002 |
114 | Clear Sky | 12/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 5.1267E-002 |
115 | Clear Turbid Sky | 12/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 9.8624E-002 |
116 | Clear Turbid Sky | 12/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 5.5978E-002 |
117 | Intermediate Sky | 12/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 7.1619E-002 |
118 | Intermediate Sky | 12/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 3.4614E-002 |
119 | Overcast Sky | 12/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 3.1562E-002 |
120 | Overcast Sky | 12/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 1.4625E-002 |
121 | Clear Sky | 12/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 3.9662E-002 |
122 | Clear Sky | 12/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 2.2966E-002 |
123 | Clear Turbid Sky | 12/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 3.7467E-002 |
124 | Clear Turbid Sky | 12/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 2.1163E-002 |
125 | Intermediate Sky | 12/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 3.9672E-002 |
126 | Intermediate Sky | 12/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 1.9727E-002 |
127 | Overcast Sky | 12/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 3.1884E-002 |
128 | Overcast Sky | 12/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 1.4841E-002 |
129 | Clear Sky | 12/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 2.6011E-002 |
130 | Clear Sky | 12/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 1.7356E-002 |
131 | Clear Turbid Sky | 12/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 2.0572E-002 |
132 | Clear Turbid Sky | 12/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 1.3690E-002 |
133 | Intermediate Sky | 12/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 1.9744E-002 |
134 | Intermediate Sky | 12/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 1.0393E-002 |
135 | Overcast Sky | 12/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 3.1562E-002 |
136 | Overcast Sky | 12/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 1.4625E-002 |
137 | Clear Sky | 12/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 3.4255E-002 |
138 | Clear Sky | 12/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 2.0484E-002 |
139 | Clear Turbid Sky | 12/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 3.0863E-002 |
140 | Clear Turbid Sky | 12/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 1.8126E-002 |
141 | Intermediate Sky | 12/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 3.4754E-002 |
142 | Intermediate Sky | 12/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 1.7501E-002 |
143 | Overcast Sky | 12/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 3.1884E-002 |
144 | Overcast Sky | 12/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 1.4842E-002 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | CORE_BOTTOM | Cooling | 37928.88292 | 37928.88292 | 3.01080 | 3.01080 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 30.95800 | 5.61598E-003 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
2 | CORE_BOTTOM | Heating | 4259.15940 | 4259.15940 | 0.19842 | 0.42469 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 0.50000 | 4.31558E-003 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
3 | CORE_MID | Cooling | 27778.43144 | 27778.43144 | 2.20251 | 2.20251 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 30.95800 | 5.61598E-003 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
4 | CORE_MID | Heating | 11203.90023 | 11203.90023 | 0.52113 | 0.52113 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 0.50000 | 4.31558E-003 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
5 | CORE_TOP | Cooling | 30266.49073 | 30266.49073 | 2.42228 | 2.42228 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 | 40.26800 | 5.63027E-003 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
6 | CORE_TOP | Heating | 20657.42873 | 20657.42873 | 0.96640 | 0.96640 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 0.50000 | 4.31558E-003 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
7 | PERIMETER_TOP_ZN_3 | Cooling | 10350.38780 | 10350.38780 | 0.82834 | 0.82834 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:30:00 | 40.40100 | 5.63048E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
8 | PERIMETER_TOP_ZN_3 | Heating | 8844.55954 | 8844.55954 | 0.41511 | 0.41511 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 0.50000 | 4.31558E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
9 | PERIMETER_TOP_ZN_2 | Cooling | 9282.63355 | 9282.63355 | 0.74288 | 0.74288 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:20:00 | 36.41100 | 5.62429E-003 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
10 | PERIMETER_TOP_ZN_2 | Heating | 5803.02682 | 5803.02682 | 0.27239 | 0.27239 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 0.50000 | 4.31558E-003 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
11 | PERIMETER_TOP_ZN_1 | Cooling | 11503.94398 | 11503.94398 | 0.92065 | 0.92065 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:20:00 | 40.80000 | 5.63111E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
12 | PERIMETER_TOP_ZN_1 | Heating | 8874.80972 | 8874.80972 | 0.41654 | 0.41654 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 0.50000 | 4.31558E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
13 | PERIMETER_TOP_ZN_4 | Cooling | 10534.36775 | 10534.36775 | 0.84305 | 0.84305 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 38.93800 | 5.62821E-003 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
14 | PERIMETER_TOP_ZN_4 | Heating | 5778.18922 | 5778.18922 | 0.27122 | 0.27122 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 0.50000 | 4.31558E-003 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
15 | PERIMETER_BOT_ZN_3 | Cooling | 8550.74559 | 8550.74559 | 0.68432 | 0.68432 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | 40.66700 | 5.63090E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
16 | PERIMETER_BOT_ZN_3 | Heating | 5549.38466 | 5549.38466 | 0.26003 | 0.26003 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 0.50000 | 4.31558E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
17 | PERIMETER_BOT_ZN_2 | Cooling | 8135.57625 | 8135.57625 | 0.65109 | 0.65109 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:20:00 | 36.41100 | 5.62429E-003 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
18 | PERIMETER_BOT_ZN_2 | Heating | 3705.59501 | 3705.59501 | 0.17368 | 0.17368 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 0.50000 | 4.31558E-003 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
19 | PERIMETER_BOT_ZN_1 | Cooling | 9555.44595 | 9555.44595 | 0.76472 | 0.76472 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 40.80000 | 5.63111E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
20 | PERIMETER_BOT_ZN_1 | Heating | 5587.94059 | 5587.94059 | 0.26185 | 0.26185 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 0.50000 | 4.31558E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
21 | PERIMETER_BOT_ZN_4 | Cooling | 8568.55888 | 8568.55888 | 0.68574 | 0.68574 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:10:00 | 38.71633 | 5.62786E-003 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
22 | PERIMETER_BOT_ZN_4 | Heating | 3680.15582 | 3680.15582 | 0.17248 | 0.17248 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 0.50000 | 4.31558E-003 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
23 | PERIMETER_MID_ZN_3 | Cooling | 8764.15550 | 8764.15550 | 0.70139 | 0.70139 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:20:00 | 40.53400 | 5.63070E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
24 | PERIMETER_MID_ZN_3 | Heating | 6577.10538 | 6577.10538 | 0.30836 | 0.30836 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 0.50000 | 4.31558E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
25 | PERIMETER_MID_ZN_2 | Cooling | 8738.47306 | 8738.47306 | 0.69933 | 0.69933 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:00:00 | 35.74600 | 5.62327E-003 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
26 | PERIMETER_MID_ZN_2 | Heating | 4363.47124 | 4363.47124 | 0.20461 | 0.20461 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 0.50000 | 4.31558E-003 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
27 | PERIMETER_MID_ZN_1 | Cooling | 9884.70613 | 9884.70613 | 0.79107 | 0.79107 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 40.80000 | 5.63111E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
28 | PERIMETER_MID_ZN_1 | Heating | 6606.03269 | 6606.03269 | 0.30972 | 0.30972 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 0.50000 | 4.31558E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
29 | PERIMETER_MID_ZN_4 | Cooling | 9317.55230 | 9317.55230 | 0.74568 | 0.74568 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 38.93800 | 5.62821E-003 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
30 | PERIMETER_MID_ZN_4 | Heating | 4338.76887 | 4338.76887 | 0.20345 | 0.20345 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 0.50000 | 4.31558E-003 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PACU_VAV_BOT | Cooling | Sensible | 87268.22 | 5.31120 | 5.31120 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 00:00:00 |
2 | PACU_VAV_BOT | Heating | Sensible | 16127.94 | 1.29273 | 1.29273 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 09:30:00 |
3 | PACU_VAV_MID | Cooling | Sensible | 78027.11 | 4.57887 | 4.57887 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 00:00:00 |
4 | PACU_VAV_MID | Heating | Sensible | 16143.21 | 1.54728 | 1.54728 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 14:50:00 |
5 | PACU_VAV_TOP | Cooling | Sensible | 89085.81 | 5.49896 | 5.49896 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 00:00:00 |
6 | PACU_VAV_TOP | Heating | Sensible | 15973.42 | 2.34167 | 2.34167 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 06:30:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 3.01080 |
2 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.24892 |
3 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.26400 |
4 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.79485 |
5 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.66379 |
6 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
7 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.53060E-003 |
8 | Coil:Heating:Electric | CORE_BOTTOM VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 24100.66089 |
9 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 2.20251 |
10 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.34027 |
11 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.34600 |
12 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.76207 |
13 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.90739 |
14 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
15 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.11969E-003 |
16 | Coil:Heating:Electric | CORE_MID VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 23106.71871 |
17 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 2.42228 |
18 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.30940 |
19 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.33100 |
20 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.80178 |
21 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.82507 |
22 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
23 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.23141E-003 |
24 | Coil:Heating:Electric | CORE_TOP VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 29302.32408 |
25 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.82834 |
26 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.19073 |
27 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20400 |
28 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.16898 |
29 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.50862 |
30 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
31 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.99755E-003 |
32 | Coil:Heating:Electric | PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 12586.61859 |
33 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.74288 |
34 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.13464 |
35 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
36 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.14858 |
37 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.35904 |
38 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
39 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.82976E-003 |
40 | Coil:Heating:Electric | PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 8259.18057 |
41 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.92065 |
42 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.17161 |
43 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
44 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.18413 |
45 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.45762 |
46 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
47 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.22018E-003 |
48 | Coil:Heating:Electric | PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 12629.81507 |
49 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.84305 |
50 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.11863 |
51 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
52 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.16861 |
53 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.31636 |
54 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
55 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.21155E-003 |
56 | Coil:Heating:Electric | PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 8223.71596 |
57 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.68432 |
58 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.23087 |
59 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.24500 |
60 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.16766 |
61 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.61567 |
62 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
63 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.65025E-003 |
64 | Coil:Heating:Electric | PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 7884.39535 |
65 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.65109 |
66 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.15362 |
67 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
68 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.13022 |
69 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.40966 |
70 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
71 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.48011E-003 |
72 | Coil:Heating:Electric | PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 5266.07315 |
73 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.76472 |
74 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.20660 |
75 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.21900 |
76 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.16747 |
77 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.55093 |
78 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
79 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.84415E-003 |
80 | Coil:Heating:Electric | PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 7939.44357 |
81 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.68574 |
82 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.14585 |
83 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
84 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.13715 |
85 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.38893 |
86 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
87 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.61227E-003 |
88 | Coil:Heating:Electric | PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 5229.76342 |
89 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.70139 |
90 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.22525 |
91 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.22900 |
92 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.16062 |
93 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.60068 |
94 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
95 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.69143E-003 |
96 | Coil:Heating:Electric | PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 9349.73883 |
97 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.69933 |
98 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.14302 |
99 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
100 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.13987 |
101 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.38140 |
102 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
103 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.66388E-003 |
104 | Coil:Heating:Electric | PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 6204.11137 |
105 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.79107 |
106 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.19972 |
107 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20300 |
108 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.16059 |
109 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.53258 |
110 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
111 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.90768E-003 |
112 | Coil:Heating:Electric | PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 9390.99644 |
113 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.74568 |
114 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.13413 |
115 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20000 |
116 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.14914 |
117 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.35767 |
118 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
119 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.84060E-003 |
120 | Coil:Heating:Electric | PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 6168.84053 |
121 | AirLoopHVAC | PACU_VAV_BOT | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.89833 |
122 | AirLoopHVAC | PACU_VAV_BOT | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.39735 |
123 | AirLoopHVAC | PACU_VAV_BOT | Sum of Air Terminal Maximum Flow Rates [m3/s] | 5.79667 |
124 | AirLoopHVAC | PACU_VAV_BOT | Adjusted Heating Design Air Flow Rate [m3/s] | 1.39735 |
125 | AirLoopHVAC | PACU_VAV_BOT | Adjusted Cooling Design Air Flow Rate [m3/s] | 5.31120 |
126 | AirLoopHVAC | PACU_VAV_BOT | Adjusted Main Design Air Flow Rate [m3/s] | 5.31120 |
127 | AirLoopHVAC | PACU_VAV_BOT | User Heating Air Flow Ratio [] | 0.30000 |
128 | AirLoopHVAC | PACU_VAV_BOT | Calculated Heating Air Flow Ratio [] | 0.26309 |
129 | AirLoopHVAC | PACU_VAV_MID | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.56999 |
130 | AirLoopHVAC | PACU_VAV_MID | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.37228 |
131 | AirLoopHVAC | PACU_VAV_MID | Sum of Air Terminal Maximum Flow Rates [m3/s] | 5.13999 |
132 | AirLoopHVAC | PACU_VAV_MID | Adjusted Heating Design Air Flow Rate [m3/s] | 1.54728 |
133 | AirLoopHVAC | PACU_VAV_MID | Adjusted Cooling Design Air Flow Rate [m3/s] | 4.57887 |
134 | AirLoopHVAC | PACU_VAV_MID | Adjusted Main Design Air Flow Rate [m3/s] | 4.57887 |
135 | AirLoopHVAC | PACU_VAV_MID | User Heating Air Flow Ratio [] | 0.30000 |
136 | AirLoopHVAC | PACU_VAV_MID | Calculated Heating Air Flow Ratio [] | 0.33792 |
137 | AirLoopHVAC | PACU_VAV_TOP | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.87860 |
138 | AirLoopHVAC | PACU_VAV_TOP | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.47207 |
139 | AirLoopHVAC | PACU_VAV_TOP | Sum of Air Terminal Maximum Flow Rates [m3/s] | 5.75721 |
140 | AirLoopHVAC | PACU_VAV_TOP | Adjusted Heating Design Air Flow Rate [m3/s] | 2.34167 |
141 | AirLoopHVAC | PACU_VAV_TOP | Adjusted Cooling Design Air Flow Rate [m3/s] | 5.49896 |
142 | AirLoopHVAC | PACU_VAV_TOP | Adjusted Main Design Air Flow Rate [m3/s] | 5.49896 |
143 | AirLoopHVAC | PACU_VAV_TOP | User Heating Air Flow Ratio [] | 0.30000 |
144 | AirLoopHVAC | PACU_VAV_TOP | Calculated Heating Air Flow Ratio [] | 0.42584 |
145 | AirLoopHVAC | PACU_VAV_BOT | Design Supply Air Flow Rate [m3/s] | 5.31120 |
146 | AirLoopHVAC | PACU_VAV_MID | Design Supply Air Flow Rate [m3/s] | 4.57887 |
147 | AirLoopHVAC | PACU_VAV_TOP | Design Supply Air Flow Rate [m3/s] | 5.49896 |
148 | Controller:OutdoorAir | PACU_VAV_BOT_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 5.31120 |
149 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size High Speed Rated Air Flow Rate [m3/s] | 5.31120 |
150 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size High Speed Gross Rated Total Cooling Capacity [W] | 106278.63679 |
151 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size High Speed Rated Sensible Heat Ratio | 0.77614 |
152 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size Low Speed Rated Air Flow Rate [m3/s] | 1.77022 |
153 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size Low Speed Gross Rated Total Cooling Capacity [W] | 35422.66964 |
154 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size Low Speed Gross Rated Sensible Heat Ratio | 0.77614 |
155 | Coil:Heating:Fuel | PACU_VAV_BOT HEATING COIL | Design Size Nominal Capacity [W] | 12561.92856 |
156 | Fan:VariableVolume | PACU_VAV_BOT FAN | Design Size Maximum Flow Rate [m3/s] | 5.31120 |
157 | Controller:OutdoorAir | PACU_VAV_MID_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 4.57887 |
158 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size High Speed Rated Air Flow Rate [m3/s] | 4.57887 |
159 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size High Speed Gross Rated Total Cooling Capacity [W] | 94887.63968 |
160 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size High Speed Rated Sensible Heat Ratio | 0.76268 |
161 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size Low Speed Rated Air Flow Rate [m3/s] | 1.52614 |
162 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size Low Speed Gross Rated Total Cooling Capacity [W] | 31626.05030 |
163 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size Low Speed Gross Rated Sensible Heat Ratio | 0.76268 |
164 | Coil:Heating:Fuel | PACU_VAV_MID HEATING COIL | Design Size Nominal Capacity [W] | 14540.89658 |
165 | Fan:VariableVolume | PACU_VAV_MID FAN | Design Size Maximum Flow Rate [m3/s] | 4.57887 |
166 | Controller:OutdoorAir | PACU_VAV_TOP_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 5.49896 |
167 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size High Speed Rated Air Flow Rate [m3/s] | 5.49896 |
168 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size High Speed Gross Rated Total Cooling Capacity [W] | 109004.22941 |
169 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size High Speed Rated Sensible Heat Ratio | 0.78002 |
170 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size Low Speed Rated Air Flow Rate [m3/s] | 1.83280 |
171 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size Low Speed Gross Rated Total Cooling Capacity [W] | 36331.10966 |
172 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size Low Speed Gross Rated Sensible Heat Ratio | 0.78002 |
173 | Coil:Heating:Fuel | PACU_VAV_TOP HEATING COIL | Design Size Nominal Capacity [W] | 13322.17334 |
174 | Fan:VariableVolume | PACU_VAV_TOP FAN | Design Size Maximum Flow Rate [m3/s] | 5.49896 |
175 | PlantLoop | SWHSYS1 | Maximum Loop Flow Rate [m3/s] | 5.36267E-005 |
176 | PlantLoop | SWHSYS1 | Plant Loop Volume [m3] | 6.43520E-003 |
177 | Pump:ConstantSpeed | SWHSYS1 PUMP | Design Flow Rate [m3/s] | 5.36267E-005 |
178 | Pump:ConstantSpeed | SWHSYS1 PUMP | Design Power Consumption [W] | 0.72612 |
179 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | Use Side Design Flow Rate [m3/s] | 5.36267E-005 |
DX Coil Type | DX Coil Name | Fan Type | Fan Name | Standard Net Cooling Capacity {W} | Standard Net Cooling Capacity {Btu/h} | IEER {Btu/W-h} | COP 100% Capacity {W/W} | COP 75% Capacity {W/W} | COP 50% Capacity {W/W} | COP 25% Capacity {W/W} | EER 100% Capacity {Btu/W-h} | EER 75% Capacity {Btu/W-h} | EER 50% Capacity {Btu/W-h} | EER 25% Capacity {Btu/W-h} | Supply Air Flow 100% {kg/s} | Supply Air Flow 75% {kg/s} | Supply Air Flow 50% {kg/s} | Supply Air Flow 25% {kg/s} | |
1 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | N/A | N/A | 105307.51 | 359324.14 | 11.40 | 2.89 | 3.27 | 3.44 | 3.60 | 9.85 | 11.14 | 11.74 | 12.30 | 5.5769 | 4.4548 | 3.0006 | 1.2138 |
2 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | N/A | N/A | 94146.70 | 321241.88 | 11.47 | 2.90 | 3.29 | 3.46 | 3.62 | 9.90 | 11.21 | 11.82 | 12.34 | 4.8079 | 3.8364 | 2.5832 | 1.0576 |
3 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | N/A | N/A | 107968.33 | 368403.24 | 11.38 | 2.88 | 3.26 | 3.43 | 3.60 | 9.83 | 11.12 | 11.71 | 12.28 | 5.7740 | 4.6146 | 3.1085 | 1.2525 |
Zone Name | # Surfaces | |
1 | CORE_BOTTOM | 7 |
2 | TOPFLOOR_PLENUM | 10 |
3 | MIDFLOOR_PLENUM | 14 |
4 | FIRSTFLOOR_PLENUM | 14 |
5 | CORE_MID | 7 |
6 | CORE_TOP | 7 |
7 | PERIMETER_TOP_ZN_3 | 8 |
8 | PERIMETER_TOP_ZN_2 | 8 |
9 | PERIMETER_TOP_ZN_1 | 8 |
10 | PERIMETER_TOP_ZN_4 | 8 |
11 | PERIMETER_BOT_ZN_3 | 12 |
12 | PERIMETER_BOT_ZN_2 | 10 |
13 | PERIMETER_BOT_ZN_1 | 12 |
14 | PERIMETER_BOT_ZN_4 | 10 |
15 | PERIMETER_MID_ZN_3 | 8 |
16 | PERIMETER_MID_ZN_2 | 8 |
17 | PERIMETER_MID_ZN_1 | 8 |
18 | PERIMETER_MID_ZN_4 | 8 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | CORE_BOT_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_BOT_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | CORE_BOT_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_BOT_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
3 | CORE_BOT_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_BOT_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
4 | CORE_BOT_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_BOT_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
5 | CORE_BOT_ZN_5_FLOOR | Floor | CTF - ConductionTransferFunction | CORE_BOT_ZN_5_FLOOR_FFACTOR | 5.650E-003 | 5.642E-003 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | CORE_BOT_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
6 | CORE_BOT_ZN_5_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 983.54 | 983.54 | 983.54 | 180.00 | 0.00 | 40.76 | 24.13 | 0.00 | iz-CORE_BOT_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
7 | CORE_BOTTOM_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 1967.08 | 1967.08 | 1967.08 | 0.00 | 90.00 | 1967.08 | 1.00 | 0.00 | CORE_BOTTOM_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
8 | PERIMETER_TOP_PLENUM_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.375 | 1.140 | 60.85 | 60.85 | 60.85 | 0.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
9 | PERIMETER_TOP_PLENUM_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.375 | 1.140 | 40.57 | 40.57 | 40.57 | 90.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
10 | PERIMETER_TOP_PLENUM_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.375 | 1.140 | 60.85 | 60.85 | 60.85 | 180.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
11 | PERIMETER_TOP_PLENUM_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.375 | 1.140 | 40.57 | 40.57 | 40.57 | 270.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
12 | iz-PERIMETER_TOP_ZN_1_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 225.00 | 180.00 | 6.47 | 40.76 | 0.00 | PERIMETER_TOP_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
13 | iz-PERIMETER_TOP_ZN_2_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.26 | 131.26 | 131.26 | 135.00 | 180.00 | 6.47 | 24.13 | 0.00 | PERIMETER_TOP_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
14 | iz-PERIMETER_TOP_ZN_3_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 45.00 | 180.00 | 6.47 | 40.76 | 0.00 | PERIMETER_TOP_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
15 | iz-PERIMETER_TOP_ZN_4_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.25 | 131.25 | 131.25 | 315.00 | 180.00 | 6.47 | 24.13 | 0.00 | PERIMETER_TOP_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
16 | iz-CORE_TOP_ZN_5_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 983.54 | 983.54 | 983.54 | 180.00 | 180.00 | 40.76 | 24.13 | 0.00 | CORE_TOP_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
17 | BUILDING_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 1660.73 | 1660.73 | 1660.73 | 0.00 | 0.00 | 49.91 | 33.27 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
18 | PERIMETER_MID_PLENUM_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.013 | 0.880 | 60.85 | 60.85 | 60.85 | 0.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
19 | PERIMETER_MID_PLENUM_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.013 | 0.880 | 40.57 | 40.57 | 40.57 | 90.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
20 | PERIMETER_MID_PLENUM_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.013 | 0.880 | 60.85 | 60.85 | 60.85 | 180.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
21 | PERIMETER_MID_PLENUM_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.013 | 0.880 | 40.57 | 40.57 | 40.57 | 270.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
22 | iz-PERIMETER_MID_ZN_1_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | PERIMETER_MID_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
23 | iz-PERIMETER_MID_ZN_2_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | PERIMETER_MID_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
24 | iz-PERIMETER_MID_ZN_3_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | PERIMETER_MID_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
25 | iz-PERIMETER_MID_ZN_4_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | PERIMETER_MID_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
26 | iz-CORE_MID_ZN_5_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | CORE_MID_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
27 | iz-PERIMETER_TOP_ZN_1_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 207.34 | 207.34 | 207.34 | 0.00 | 0.00 | 40.76 | 6.47 | 0.00 | PERIMETER_TOP_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
28 | iz-PERIMETER_TOP_ZN_2_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 131.26 | 131.26 | 131.26 | 270.00 | 0.00 | 24.13 | 6.47 | 0.00 | PERIMETER_TOP_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
29 | iz-PERIMETER_TOP_ZN_3_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 207.34 | 207.34 | 207.34 | 180.00 | 0.00 | 40.76 | 6.47 | 0.00 | PERIMETER_TOP_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
30 | iz-PERIMETER_TOP_ZN_4_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 131.25 | 131.25 | 131.25 | 90.00 | 0.00 | 24.13 | 6.47 | 0.00 | PERIMETER_TOP_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
31 | iz-CORE_TOP_ZN_5_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 983.54 | 983.54 | 983.54 | 180.00 | 0.00 | 40.76 | 24.13 | 0.00 | CORE_TOP_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
32 | PERIMETER_BOT_PLENUM_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.029 | 0.892 | 60.85 | 60.85 | 60.85 | 0.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
33 | PERIMETER_BOT_PLENUM_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.029 | 0.892 | 40.57 | 40.57 | 40.57 | 90.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
34 | PERIMETER_BOT_PLENUM_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.029 | 0.892 | 60.85 | 60.85 | 60.85 | 180.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
35 | PERIMETER_BOT_PLENUM_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.029 | 0.892 | 40.57 | 40.57 | 40.57 | 270.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
36 | iz-PERIMETER_BOT_ZN_1_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | PERIMETER_BOT_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
37 | iz-PERIMETER_BOT_ZN_2_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | PERIMETER_BOT_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
38 | iz-PERIMETER_BOT_ZN_3_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | PERIMETER_BOT_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
39 | iz-PERIMETER_BOT_ZN_4_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | PERIMETER_BOT_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
40 | iz-CORE_BOT_ZN_5_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | CORE_BOT_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
41 | iz-PERIMETER_MID_ZN_1_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 207.34 | 207.34 | 207.34 | 0.00 | 0.00 | 40.76 | 6.47 | 0.00 | PERIMETER_MID_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
42 | iz-PERIMETER_MID_ZN_2_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 131.26 | 131.26 | 131.26 | 270.00 | 0.00 | 24.13 | 6.47 | 0.00 | PERIMETER_MID_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
43 | iz-PERIMETER_MID_ZN_3_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 207.34 | 207.34 | 207.34 | 180.00 | 0.00 | 40.76 | 6.47 | 0.00 | PERIMETER_MID_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
44 | iz-PERIMETER_MID_ZN_4_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 131.25 | 131.25 | 131.25 | 90.00 | 0.00 | 24.13 | 6.47 | 0.00 | PERIMETER_MID_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
45 | iz-CORE_MID_ZN_5_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 983.54 | 983.54 | 983.54 | 180.00 | 0.00 | 40.76 | 24.13 | 0.00 | CORE_MID_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
46 | CORE_MID_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_MID_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
47 | CORE_MID_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_MID_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
48 | CORE_MID_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_MID_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
49 | CORE_MID_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_MID_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
50 | CORE_MID_ZN_5_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | iz-CORE_MID_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
51 | CORE_MID_ZN_5_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 983.54 | 983.54 | 983.54 | 180.00 | 0.00 | 40.76 | 24.13 | 0.00 | iz-CORE_MID_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
52 | CORE_MID_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 1967.08 | 1967.08 | 1967.08 | 0.00 | 90.00 | 1967.08 | 1.00 | 0.00 | CORE_MID_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
53 | CORE_TOP_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_TOP_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
54 | CORE_TOP_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_TOP_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
55 | CORE_TOP_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_TOP_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
56 | CORE_TOP_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_TOP_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
57 | CORE_TOP_ZN_5_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | iz-CORE_TOP_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
58 | CORE_TOP_ZN_5_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 983.54 | 983.54 | 983.54 | 0.00 | 0.00 | 40.76 | 24.13 | 0.00 | iz-CORE_TOP_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
59 | CORE_TOP_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 1967.08 | 1967.08 | 1967.08 | 0.00 | 90.00 | 1967.08 | 1.00 | 0.00 | CORE_TOP_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
60 | PERIMETER_TOP_ZN_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.375 | 1.140 | 77.59 | 136.92 | 77.59 | 0.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | Window | PERIMETER_TOP_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.4547_SHGC_NORTH_0.25 | N/A | 2.584 | No | 59.33 | 59.33 | 59.33 | 0.00 | 90.00 | 49.91 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
62 | PERIMETER_TOP_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_TOP_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
63 | iz-PERIMETER_TOP_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
64 | iz-CORE_TOP_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
65 | PERIMETER_TOP_ZN_3_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_TOP_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
66 | PERIMETER_TOP_ZN_3_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 225.00 | 0.00 | 6.47 | 49.91 | 0.00 | iz-PERIMETER_TOP_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
67 | PERIMETER_TOP_ZN_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.68 | 414.68 | 414.68 | 0.00 | 90.00 | 414.68 | 1.00 | 0.00 | PERIMETER_TOP_ZN_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
68 | PERIMETER_TOP_ZN_2_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.375 | 1.140 | 51.72 | 91.28 | 51.72 | 90.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
69 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | Window | PERIMETER_TOP_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.4547_SHGC_EAST_0.25 | N/A | 2.584 | No | 39.55 | 39.55 | 39.55 | 90.00 | 90.00 | 33.27 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
70 | PERIMETER_TOP_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_TOP_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
71 | iz-PERIMETER_TOP_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
72 | iz-CORE_TOP_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
73 | PERIMETER_TOP_ZN_2_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_TOP_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
74 | PERIMETER_TOP_ZN_2_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.26 | 131.26 | 131.26 | 315.00 | 0.00 | 6.47 | 33.27 | 0.00 | iz-PERIMETER_TOP_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
75 | PERIMETER_TOP_ZN_2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_TOP_ZN_2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
76 | PERIMETER_TOP_ZN_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.375 | 1.140 | 77.59 | 136.92 | 77.59 | 180.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
77 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | Window | PERIMETER_TOP_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.4547_SHGC_SOUTH_0.25 | N/A | 2.584 | No | 59.33 | 59.33 | 59.33 | 180.00 | 90.00 | 49.91 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
78 | PERIMETER_TOP_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_TOP_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
79 | iz-PERIMETER_TOP_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
80 | iz-CORE_TOP_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
81 | PERIMETER_TOP_ZN_1_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_TOP_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
82 | PERIMETER_TOP_ZN_1_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 45.00 | 0.00 | 6.47 | 49.91 | 0.00 | iz-PERIMETER_TOP_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
83 | PERIMETER_TOP_ZN_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.67 | 414.67 | 414.67 | 0.00 | 90.00 | 414.67 | 1.00 | 0.00 | PERIMETER_TOP_ZN_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
84 | PERIMETER_TOP_ZN_4_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.375 | 1.140 | 51.72 | 91.28 | 51.72 | 270.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
85 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | Window | PERIMETER_TOP_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.4547_SHGC_WEST_0.25 | N/A | 2.584 | No | 39.55 | 39.55 | 39.55 | 270.00 | 90.00 | 33.27 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
86 | PERIMETER_TOP_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_TOP_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
87 | iz-PERIMETER_TOP_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
88 | iz-CORE_TOP_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
89 | PERIMETER_TOP_ZN_4_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_TOP_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
90 | PERIMETER_TOP_ZN_4_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.25 | 131.25 | 131.25 | 135.00 | 0.00 | 6.47 | 33.27 | 0.00 | iz-PERIMETER_TOP_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
91 | PERIMETER_TOP_ZN_4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_TOP_ZN_4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
92 | PERIMETER_BOT_ZN_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.029 | 0.892 | 73.69 | 136.92 | 73.69 | 0.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
93 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | Window | PERIMETER_BOT_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.4547_SHGC_NORTH_0.25 | N/A | 2.584 | No | 19.78 | 19.78 | 19.78 | 0.00 | 90.00 | 15.82 | 1.25 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
94 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | Window | PERIMETER_BOT_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.4547_SHGC_NORTH_0.25 | N/A | 2.584 | No | 19.78 | 19.78 | 19.78 | 0.00 | 90.00 | 15.82 | 1.25 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
95 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | Window | PERIMETER_BOT_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.4547_SHGC_NORTH_0.25 | N/A | 2.584 | No | 19.78 | 19.78 | 19.78 | 0.00 | 90.00 | 15.82 | 1.25 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
96 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | Door | PERIMETER_BOT_ZN_3_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
97 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | Door | PERIMETER_BOT_ZN_3_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
98 | PERIMETER_BOT_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_BOT_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
99 | iz-PERIMETER_BOT_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
100 | iz-CORE_BOT_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
101 | PERIMETER_BOT_ZN_3_FLOOR | Floor | CTF - ConductionTransferFunction | PERIMETER_BOT_ZN_3_FLOOR_FFACTOR | 0.319 | 0.296 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
102 | PERIMETER_BOT_ZN_3_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 180.00 | 0.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_BOT_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
103 | PERIMETER_BOT_ZN_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.68 | 414.68 | 414.68 | 0.00 | 90.00 | 414.68 | 1.00 | 0.00 | PERIMETER_BOT_ZN_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
104 | PERIMETER_BOT_ZN_2_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.029 | 0.892 | 49.77 | 91.28 | 49.77 | 90.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
105 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | Window | PERIMETER_BOT_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.4547_SHGC_EAST_0.25 | N/A | 2.584 | No | 38.05 | 38.05 | 38.05 | 90.00 | 90.00 | 30.84 | 1.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
106 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | Window | PERIMETER_BOT_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.4547_SHGC_EAST_0.25 | N/A | 2.584 | No | 1.50 | 1.50 | 1.50 | 90.00 | 90.00 | 1.22 | 1.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
107 | PERIMETER_BOT_ZN_2_WALL_EAST_DOOR | Door | PERIMETER_BOT_ZN_2_WALL_EAST | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
108 | PERIMETER_BOT_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_BOT_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
109 | iz-PERIMETER_BOT_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
110 | iz-CORE_BOT_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
111 | PERIMETER_BOT_ZN_2_FLOOR | Floor | CTF - ConductionTransferFunction | PERIMETER_BOT_ZN_2_FLOOR_FFACTOR | 0.337 | 0.312 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
112 | PERIMETER_BOT_ZN_2_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.26 | 131.26 | 131.26 | 270.00 | 0.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_BOT_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
113 | PERIMETER_BOT_ZN_2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_BOT_ZN_2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
114 | PERIMETER_BOT_ZN_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.029 | 0.892 | 73.69 | 136.92 | 73.69 | 180.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
115 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | Window | PERIMETER_BOT_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.4547_SHGC_SOUTH_0.25 | N/A | 2.584 | No | 19.78 | 19.78 | 19.78 | 180.00 | 90.00 | 15.82 | 1.25 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
116 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | Window | PERIMETER_BOT_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.4547_SHGC_SOUTH_0.25 | N/A | 2.584 | No | 19.78 | 19.78 | 19.78 | 180.00 | 90.00 | 15.82 | 1.25 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
117 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | Window | PERIMETER_BOT_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.4547_SHGC_SOUTH_0.25 | N/A | 2.584 | No | 19.78 | 19.78 | 19.78 | 180.00 | 90.00 | 15.82 | 1.25 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
118 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | Door | PERIMETER_BOT_ZN_1_WALL_SOUTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 180.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
119 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | Door | PERIMETER_BOT_ZN_1_WALL_SOUTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 180.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
120 | PERIMETER_BOT_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_BOT_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
121 | iz-PERIMETER_BOT_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
122 | iz-CORE_BOT_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
123 | PERIMETER_BOT_ZN_1_FLOOR | Floor | CTF - ConductionTransferFunction | PERIMETER_BOT_ZN_1_FLOOR_FFACTOR | 0.319 | 0.296 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
124 | PERIMETER_BOT_ZN_1_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 0.00 | 0.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_BOT_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
125 | PERIMETER_BOT_ZN_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.67 | 414.67 | 414.67 | 0.00 | 90.00 | 414.67 | 1.00 | 0.00 | PERIMETER_BOT_ZN_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
126 | PERIMETER_BOT_ZN_4_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 1.029 | 0.892 | 49.77 | 91.28 | 49.77 | 270.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
127 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | Window | PERIMETER_BOT_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.4547_SHGC_WEST_0.25 | N/A | 2.584 | No | 38.05 | 38.05 | 38.05 | 270.00 | 90.00 | 30.84 | 1.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
128 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | Window | PERIMETER_BOT_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.4547_SHGC_WEST_0.25 | N/A | 2.584 | No | 1.50 | 1.50 | 1.50 | 270.00 | 90.00 | 1.22 | 1.23 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
129 | PERIMETER_BOT_ZN_4_WALL_WEST_DOOR | Door | PERIMETER_BOT_ZN_4_WALL_WEST | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
130 | PERIMETER_BOT_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_BOT_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
131 | iz-PERIMETER_BOT_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
132 | iz-CORE_BOT_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
133 | PERIMETER_BOT_ZN_4_FLOOR | Floor | CTF - ConductionTransferFunction | PERIMETER_BOT_ZN_4_FLOOR_FFACTOR | 0.337 | 0.312 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
134 | PERIMETER_BOT_ZN_4_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.25 | 131.25 | 131.25 | 90.00 | 0.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_BOT_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
135 | PERIMETER_BOT_ZN_4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_BOT_ZN_4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
136 | PERIMETER_MID_ZN_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.013 | 0.880 | 77.59 | 136.92 | 77.59 | 0.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
137 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | Window | PERIMETER_MID_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.4547_SHGC_NORTH_0.25 | N/A | 2.584 | No | 59.33 | 59.33 | 59.33 | 0.00 | 90.00 | 49.91 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
138 | PERIMETER_MID_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_MID_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
139 | iz-PERIMETER_MID_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
140 | iz-CORE_MID_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
141 | PERIMETER_MID_ZN_3_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
142 | PERIMETER_MID_ZN_3_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 180.00 | 0.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
143 | PERIMETER_MID_ZN_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.68 | 414.68 | 414.68 | 0.00 | 90.00 | 414.68 | 1.00 | 0.00 | PERIMETER_MID_ZN_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
144 | PERIMETER_MID_ZN_2_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.013 | 0.880 | 51.72 | 91.28 | 51.72 | 90.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
145 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | Window | PERIMETER_MID_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.4547_SHGC_EAST_0.25 | N/A | 2.584 | No | 39.55 | 39.55 | 39.55 | 90.00 | 90.00 | 33.27 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
146 | PERIMETER_MID_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_MID_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
147 | iz-PERIMETER_MID_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
148 | iz-CORE_MID_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
149 | PERIMETER_MID_ZN_2_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
150 | PERIMETER_MID_ZN_2_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.26 | 131.26 | 131.26 | 270.00 | 0.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
151 | PERIMETER_MID_ZN_2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_MID_ZN_2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
152 | PERIMETER_MID_ZN_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.013 | 0.880 | 77.59 | 136.92 | 77.59 | 180.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
153 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | Window | PERIMETER_MID_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.4547_SHGC_SOUTH_0.25 | N/A | 2.584 | No | 59.33 | 59.33 | 59.33 | 180.00 | 90.00 | 49.91 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
154 | PERIMETER_MID_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_MID_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
155 | iz-PERIMETER_MID_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
156 | iz-CORE_MID_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
157 | PERIMETER_MID_ZN_1_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
158 | PERIMETER_MID_ZN_1_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 0.00 | 0.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
159 | PERIMETER_MID_ZN_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.67 | 414.67 | 414.67 | 0.00 | 90.00 | 414.67 | 1.00 | 0.00 | PERIMETER_MID_ZN_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
160 | PERIMETER_MID_ZN_4_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 1.013 | 0.880 | 51.72 | 91.28 | 51.72 | 270.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
161 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | Window | PERIMETER_MID_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.4547_SHGC_WEST_0.25 | N/A | 2.584 | No | 39.55 | 39.55 | 39.55 | 270.00 | 90.00 | 33.27 | 1.19 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
162 | PERIMETER_MID_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_MID_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
163 | iz-PERIMETER_MID_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
164 | iz-CORE_MID_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
165 | PERIMETER_MID_ZN_4_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
166 | PERIMETER_MID_ZN_4_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.25 | 131.25 | 131.25 | 90.00 | 0.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
167 | PERIMETER_MID_ZN_4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_MID_ZN_4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes | Clark and Allen |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1Environment:Special Days |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | CORE_BOTTOM | RunPeriod: RUNPERIOD 1 | 5.7305956530E-002 | 0.1279742000 | Pass | Pass | 6.3596293955E-002 | 0.2411953407 | Pass | Pass |
2 | TOPFLOOR_PLENUM | RunPeriod: RUNPERIOD 1 | 0.1068683749 | 7.2105822445E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
3 | MIDFLOOR_PLENUM | RunPeriod: RUNPERIOD 1 | 2.5375749005E-002 | 2.9421026220E-002 | Pass | Pass | 6.0513621287E-002 | 0.3343317361 | Pass | Pass |
4 | FIRSTFLOOR_PLENUM | RunPeriod: RUNPERIOD 1 | 2.1853029065E-002 | 2.3731865964E-002 | Pass | Pass | 0.1864448803 | 0.8553647288 | Pass | Pass |
5 | CORE_MID | RunPeriod: RUNPERIOD 1 | 3.9973938414E-002 | 9.0245243810E-002 | Pass | Pass | 3.5018689663E-002 | 0.1815400853 | Pass | Pass |
6 | CORE_TOP | RunPeriod: RUNPERIOD 1 | 3.4492442178E-002 | 1.7237952065E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
7 | PERIMETER_TOP_ZN_3 | RunPeriod: RUNPERIOD 1 | 5.1798397873E-002 | 2.6788252352E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
8 | PERIMETER_TOP_ZN_2 | RunPeriod: RUNPERIOD 1 | 6.5354292683E-002 | 7.2763240911E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
9 | PERIMETER_TOP_ZN_1 | RunPeriod: RUNPERIOD 1 | 0.1336922886 | 9.5703992587E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
10 | PERIMETER_TOP_ZN_4 | RunPeriod: RUNPERIOD 1 | 0.1149960793 | 9.8517126153E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
11 | PERIMETER_BOT_ZN_3 | RunPeriod: RUNPERIOD 1 | 5.3685597495E-002 | 7.0517849943E-002 | Pass | Pass | 6.3216273902E-002 | 0.2404039349 | Pass | Pass |
12 | PERIMETER_BOT_ZN_2 | RunPeriod: RUNPERIOD 1 | 8.2679542258E-002 | 0.1160384805 | Pass | Pass | 6.3871678926E-002 | 0.2423907193 | Pass | Pass |
13 | PERIMETER_BOT_ZN_1 | RunPeriod: RUNPERIOD 1 | 0.1208658606 | 0.1451663452 | Pass | Pass | 6.2814642037E-002 | 0.2414562478 | Pass | Pass |
14 | PERIMETER_BOT_ZN_4 | RunPeriod: RUNPERIOD 1 | 9.4302297756E-002 | 0.1393819915 | Pass | Pass | 6.1047131449E-002 | 0.2339217927 | Pass | Pass |
15 | PERIMETER_MID_ZN_3 | RunPeriod: RUNPERIOD 1 | 5.1596298398E-002 | 6.1051454413E-002 | Pass | Pass | 3.5016990919E-002 | 0.1809701003 | Pass | Pass |
16 | PERIMETER_MID_ZN_2 | RunPeriod: RUNPERIOD 1 | 8.5228056373E-002 | 0.1161596679 | Pass | Pass | 3.5015656860E-002 | 0.1820350114 | Pass | Pass |
17 | PERIMETER_MID_ZN_1 | RunPeriod: RUNPERIOD 1 | 0.1399433046 | 0.1315432034 | Pass | Pass | 4.5054887796E-002 | 0.2337256643 | Pass | Pass |
18 | PERIMETER_MID_ZN_4 | RunPeriod: RUNPERIOD 1 | 0.1077563203 | 0.1497029048 | Pass | Pass | 3.3295307265E-002 | 0.1744965502 | Pass | Pass |
Report: Annual Heat Emissions Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
Heat Emission by ComponentsEnvelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
Heat Emissions [GJ] | 2907.22 | 7.62 | 0.00 | 1079.31 | 1917.67 | 5911.84 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 0.50 | 0.00 | 0.50 | Wetbulb [C] | 2.10 | 140.00 |
TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 40.80 | 13.30 | 18.50 | Wetbulb [C] | 4.80 | 310.00 |
Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
Jan | 3.00 | 2 | |||
Feb | 34.00 | 28 | |||
Mar | 40.00 | 18 | |||
Apr | 0.00 | 0 | |||
May | 0.00 | 0 | |||
Jun | 0.00 | 0 | |||
Jul | 81.00 | 18 | |||
Aug | 71.00 | 20 | |||
Sep | 27.00 | 12 | |||
Oct | 9.00 | 6 | |||
Nov | 35.00 | 14 | |||
Dec | 0.00 | 0 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
PERIMETER_TOP_PLENUM_WALL_NORTH | NONRES_EXT_WALL_TOP | 0.30 | 1.140 | 1.375 | 60.85 | 60.85 | 0.00 | 90.00 | N |
PERIMETER_TOP_PLENUM_WALL_EAST | NONRES_EXT_WALL_TOP | 0.30 | 1.140 | 1.375 | 40.57 | 40.57 | 90.00 | 90.00 | E |
PERIMETER_TOP_PLENUM_WALL_SOUTH | NONRES_EXT_WALL_TOP | 0.30 | 1.140 | 1.375 | 60.85 | 60.85 | 180.00 | 90.00 | S |
PERIMETER_TOP_PLENUM_WALL_WEST | NONRES_EXT_WALL_TOP | 0.30 | 1.140 | 1.375 | 40.57 | 40.57 | 270.00 | 90.00 | W |
BUILDING_ROOF | NONRES_ROOF | 0.55 | 0.221 | 0.228 | 1660.73 | 1660.73 | 0.00 | 0.00 | |
PERIMETER_MID_PLENUM_WALL_NORTH | NONRES_EXT_WALL_MID | 0.30 | 0.880 | 1.013 | 60.85 | 60.85 | 0.00 | 90.00 | N |
PERIMETER_MID_PLENUM_WALL_EAST | NONRES_EXT_WALL_MID | 0.30 | 0.880 | 1.013 | 40.57 | 40.57 | 90.00 | 90.00 | E |
PERIMETER_MID_PLENUM_WALL_SOUTH | NONRES_EXT_WALL_MID | 0.30 | 0.880 | 1.013 | 60.85 | 60.85 | 180.00 | 90.00 | S |
PERIMETER_MID_PLENUM_WALL_WEST | NONRES_EXT_WALL_MID | 0.30 | 0.880 | 1.013 | 40.57 | 40.57 | 270.00 | 90.00 | W |
PERIMETER_BOT_PLENUM_WALL_NORTH | NONRES_EXT_WALL_GRD | 0.30 | 0.892 | 1.029 | 60.85 | 60.85 | 0.00 | 90.00 | N |
PERIMETER_BOT_PLENUM_WALL_EAST | NONRES_EXT_WALL_GRD | 0.30 | 0.892 | 1.029 | 40.57 | 40.57 | 90.00 | 90.00 | E |
PERIMETER_BOT_PLENUM_WALL_SOUTH | NONRES_EXT_WALL_GRD | 0.30 | 0.892 | 1.029 | 60.85 | 60.85 | 180.00 | 90.00 | S |
PERIMETER_BOT_PLENUM_WALL_WEST | NONRES_EXT_WALL_GRD | 0.30 | 0.892 | 1.029 | 40.57 | 40.57 | 270.00 | 90.00 | W |
PERIMETER_TOP_ZN_3_WALL_NORTH | NONRES_EXT_WALL_TOP | 0.30 | 1.140 | 1.375 | 136.92 | 77.59 | 0.00 | 90.00 | N |
PERIMETER_TOP_ZN_2_WALL_EAST | NONRES_EXT_WALL_TOP | 0.30 | 1.140 | 1.375 | 91.28 | 51.72 | 90.00 | 90.00 | E |
PERIMETER_TOP_ZN_1_WALL_SOUTH | NONRES_EXT_WALL_TOP | 0.30 | 1.140 | 1.375 | 136.92 | 77.59 | 180.00 | 90.00 | S |
PERIMETER_TOP_ZN_4_WALL_WEST | NONRES_EXT_WALL_TOP | 0.30 | 1.140 | 1.375 | 91.28 | 51.72 | 270.00 | 90.00 | W |
PERIMETER_BOT_ZN_3_WALL_NORTH | NONRES_EXT_WALL_GRD | 0.30 | 0.892 | 1.029 | 136.92 | 73.69 | 0.00 | 90.00 | N |
PERIMETER_BOT_ZN_3_FLOOR | PERIMETER_BOT_ZN_3_FLOOR_FFACTOR | 1.00 | 0.304 | 0.319 | 207.34 | 207.34 | 0.00 | 180.00 | |
PERIMETER_BOT_ZN_2_WALL_EAST | NONRES_EXT_WALL_GRD | 0.30 | 0.892 | 1.029 | 91.28 | 49.77 | 90.00 | 90.00 | E |
PERIMETER_BOT_ZN_2_FLOOR | PERIMETER_BOT_ZN_2_FLOOR_FFACTOR | 1.00 | 0.320 | 0.337 | 131.26 | 131.26 | 90.00 | 180.00 | |
PERIMETER_BOT_ZN_1_WALL_SOUTH | NONRES_EXT_WALL_GRD | 0.30 | 0.892 | 1.029 | 136.92 | 73.69 | 180.00 | 90.00 | S |
PERIMETER_BOT_ZN_1_FLOOR | PERIMETER_BOT_ZN_1_FLOOR_FFACTOR | 1.00 | 0.304 | 0.319 | 207.34 | 207.34 | 180.00 | 180.00 | |
PERIMETER_BOT_ZN_4_WALL_WEST | NONRES_EXT_WALL_GRD | 0.30 | 0.892 | 1.029 | 91.28 | 49.77 | 270.00 | 90.00 | W |
PERIMETER_BOT_ZN_4_FLOOR | PERIMETER_BOT_ZN_4_FLOOR_FFACTOR | 1.00 | 0.320 | 0.337 | 131.25 | 131.25 | 270.00 | 180.00 | |
PERIMETER_MID_ZN_3_WALL_NORTH | NONRES_EXT_WALL_MID | 0.30 | 0.880 | 1.013 | 136.92 | 77.59 | 0.00 | 90.00 | N |
PERIMETER_MID_ZN_2_WALL_EAST | NONRES_EXT_WALL_MID | 0.30 | 0.880 | 1.013 | 91.28 | 51.72 | 90.00 | 90.00 | E |
PERIMETER_MID_ZN_1_WALL_SOUTH | NONRES_EXT_WALL_MID | 0.30 | 0.880 | 1.013 | 136.92 | 77.59 | 180.00 | 90.00 | S |
PERIMETER_MID_ZN_4_WALL_WEST | NONRES_EXT_WALL_MID | 0.30 | 0.880 | 1.013 | 91.28 | 51.72 | 270.00 | 90.00 | W |
Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
CORE_BOT_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
CORE_BOT_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
CORE_BOT_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
CORE_BOT_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
CORE_BOT_ZN_5_FLOOR | CORE_BOT_ZN_5_FLOOR_FFACTOR | 1.00 | 0.006 | 0.006 | 983.54 | 983.54 | 0.00 | 180.00 | |
CORE_BOT_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 180.00 | 0.00 | |
iz-PERIMETER_TOP_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 225.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 135.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 45.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 315.00 | 180.00 | |
iz-CORE_TOP_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 180.00 | 180.00 | |
iz-PERIMETER_MID_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 180.00 | 180.00 | |
iz-PERIMETER_MID_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 90.00 | 180.00 | |
iz-PERIMETER_MID_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 0.00 | 180.00 | |
iz-PERIMETER_MID_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 270.00 | 180.00 | |
iz-CORE_MID_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 0.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_1_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 0.00 | 0.00 | |
iz-PERIMETER_TOP_ZN_2_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 131.26 | 131.26 | 270.00 | 0.00 | |
iz-PERIMETER_TOP_ZN_3_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 180.00 | 0.00 | |
iz-PERIMETER_TOP_ZN_4_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 131.25 | 131.25 | 90.00 | 0.00 | |
iz-CORE_TOP_ZN_5_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 983.54 | 983.54 | 180.00 | 0.00 | |
iz-PERIMETER_BOT_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 180.00 | 180.00 | |
iz-PERIMETER_BOT_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 90.00 | 180.00 | |
iz-PERIMETER_BOT_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 0.00 | 180.00 | |
iz-PERIMETER_BOT_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 270.00 | 180.00 | |
iz-CORE_BOT_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 0.00 | 180.00 | |
iz-PERIMETER_MID_ZN_1_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 0.00 | 0.00 | |
iz-PERIMETER_MID_ZN_2_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 131.26 | 131.26 | 270.00 | 0.00 | |
iz-PERIMETER_MID_ZN_3_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 180.00 | 0.00 | |
iz-PERIMETER_MID_ZN_4_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 131.25 | 131.25 | 90.00 | 0.00 | |
iz-CORE_MID_ZN_5_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 983.54 | 983.54 | 180.00 | 0.00 | |
CORE_MID_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
CORE_MID_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
CORE_MID_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
CORE_MID_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
CORE_MID_ZN_5_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 983.54 | 983.54 | 0.00 | 180.00 | |
CORE_MID_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 180.00 | 0.00 | |
CORE_TOP_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
CORE_TOP_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
CORE_TOP_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
CORE_TOP_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
CORE_TOP_ZN_5_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 983.54 | 983.54 | 0.00 | 180.00 | |
CORE_TOP_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 0.00 | 0.00 | |
PERIMETER_TOP_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-PERIMETER_TOP_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-CORE_TOP_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
PERIMETER_TOP_ZN_3_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 0.00 | 180.00 | |
PERIMETER_TOP_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 225.00 | 0.00 | |
PERIMETER_TOP_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-PERIMETER_TOP_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-CORE_TOP_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
PERIMETER_TOP_ZN_2_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 131.26 | 131.26 | 90.00 | 180.00 | |
PERIMETER_TOP_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 315.00 | 0.00 | |
PERIMETER_TOP_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-PERIMETER_TOP_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-CORE_TOP_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
PERIMETER_TOP_ZN_1_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 180.00 | 180.00 | |
PERIMETER_TOP_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 45.00 | 0.00 | |
PERIMETER_TOP_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-PERIMETER_TOP_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-CORE_TOP_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
PERIMETER_TOP_ZN_4_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 131.25 | 131.25 | 270.00 | 180.00 | |
PERIMETER_TOP_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 135.00 | 0.00 | |
PERIMETER_BOT_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-PERIMETER_BOT_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-CORE_BOT_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
PERIMETER_BOT_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 180.00 | 0.00 | |
PERIMETER_BOT_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-PERIMETER_BOT_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-CORE_BOT_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
PERIMETER_BOT_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 270.00 | 0.00 | |
PERIMETER_BOT_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-PERIMETER_BOT_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-CORE_BOT_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
PERIMETER_BOT_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 0.00 | 0.00 | |
PERIMETER_BOT_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-PERIMETER_BOT_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-CORE_BOT_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
PERIMETER_BOT_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 90.00 | 0.00 | |
PERIMETER_MID_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-PERIMETER_MID_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-CORE_MID_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
PERIMETER_MID_ZN_3_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 0.00 | 180.00 | |
PERIMETER_MID_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 180.00 | 0.00 | |
PERIMETER_MID_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-PERIMETER_MID_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-CORE_MID_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
PERIMETER_MID_ZN_2_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 131.26 | 131.26 | 90.00 | 180.00 | |
PERIMETER_MID_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 270.00 | 0.00 | |
PERIMETER_MID_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-PERIMETER_MID_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-CORE_MID_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
PERIMETER_MID_ZN_1_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 180.00 | 180.00 | |
PERIMETER_MID_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 0.00 | 0.00 | |
PERIMETER_MID_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-PERIMETER_MID_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-CORE_MID_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
PERIMETER_MID_ZN_4_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 131.25 | 131.25 | 270.00 | 180.00 | |
PERIMETER_MID_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 90.00 | 0.00 | |
CORE_BOTTOM_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 1967.08 | 0.00 | 90.00 | N | ||
CORE_MID_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 1967.08 | 0.00 | 90.00 | N | ||
CORE_TOP_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 1967.08 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.68 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_2_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.67 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_4_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.68 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_2_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.67 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_4_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.68 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_2_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.67 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_4_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N |
Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | WINDOW_U_0.4547_SHGC_NORTH_0.25 | 59.33 | 0.00 | 0.00 | 59.33 | 59.33 | 2.584 | 0.251 | 0.251 | No | PERIMETER_TOP_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | WINDOW_U_0.4547_SHGC_EAST_0.25 | 39.55 | 0.00 | 0.00 | 39.55 | 39.55 | 2.584 | 0.251 | 0.251 | No | PERIMETER_TOP_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | WINDOW_U_0.4547_SHGC_SOUTH_0.25 | 59.33 | 0.00 | 0.00 | 59.33 | 59.33 | 2.584 | 0.251 | 0.251 | No | PERIMETER_TOP_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | WINDOW_U_0.4547_SHGC_WEST_0.25 | 39.55 | 0.00 | 0.00 | 39.55 | 39.55 | 2.584 | 0.251 | 0.251 | No | PERIMETER_TOP_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | WINDOW_U_0.4547_SHGC_NORTH_0.25 | 19.78 | 0.00 | 0.00 | 19.78 | 19.78 | 2.584 | 0.251 | 0.251 | No | PERIMETER_BOT_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | WINDOW_U_0.4547_SHGC_NORTH_0.25 | 19.78 | 0.00 | 0.00 | 19.78 | 19.78 | 2.584 | 0.251 | 0.251 | No | PERIMETER_BOT_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | WINDOW_U_0.4547_SHGC_NORTH_0.25 | 19.78 | 0.00 | 0.00 | 19.78 | 19.78 | 2.584 | 0.251 | 0.251 | No | PERIMETER_BOT_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | WINDOW_U_0.4547_SHGC_EAST_0.25 | 38.05 | 0.00 | 0.00 | 38.05 | 38.05 | 2.584 | 0.251 | 0.251 | No | PERIMETER_BOT_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | WINDOW_U_0.4547_SHGC_EAST_0.25 | 1.50 | 0.00 | 0.00 | 1.50 | 1.50 | 2.584 | 0.251 | 0.251 | No | PERIMETER_BOT_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | WINDOW_U_0.4547_SHGC_SOUTH_0.25 | 19.78 | 0.00 | 0.00 | 19.78 | 19.78 | 2.584 | 0.251 | 0.251 | No | PERIMETER_BOT_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | WINDOW_U_0.4547_SHGC_SOUTH_0.25 | 19.78 | 0.00 | 0.00 | 19.78 | 19.78 | 2.584 | 0.251 | 0.251 | No | PERIMETER_BOT_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | WINDOW_U_0.4547_SHGC_SOUTH_0.25 | 19.78 | 0.00 | 0.00 | 19.78 | 19.78 | 2.584 | 0.251 | 0.251 | No | PERIMETER_BOT_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | WINDOW_U_0.4547_SHGC_WEST_0.25 | 38.05 | 0.00 | 0.00 | 38.05 | 38.05 | 2.584 | 0.251 | 0.251 | No | PERIMETER_BOT_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | WINDOW_U_0.4547_SHGC_WEST_0.25 | 1.50 | 0.00 | 0.00 | 1.50 | 1.50 | 2.584 | 0.251 | 0.251 | No | PERIMETER_BOT_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | WINDOW_U_0.4547_SHGC_NORTH_0.25 | 59.33 | 0.00 | 0.00 | 59.33 | 59.33 | 2.584 | 0.251 | 0.251 | No | PERIMETER_MID_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | WINDOW_U_0.4547_SHGC_EAST_0.25 | 39.55 | 0.00 | 0.00 | 39.55 | 39.55 | 2.584 | 0.251 | 0.251 | No | PERIMETER_MID_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | WINDOW_U_0.4547_SHGC_SOUTH_0.25 | 59.33 | 0.00 | 0.00 | 59.33 | 59.33 | 2.584 | 0.251 | 0.251 | No | PERIMETER_MID_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | WINDOW_U_0.4547_SHGC_WEST_0.25 | 39.55 | 0.00 | 0.00 | 39.55 | 39.55 | 2.584 | 0.251 | 0.251 | No | PERIMETER_MID_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
Total or Average | 593.29 | 2.584 | 0.251 | 0.251 | |||||||||||||||||
North Total or Average | 177.99 | 2.584 | 0.251 | 0.251 | |||||||||||||||||
Non-North Total or Average | 415.31 | 2.584 | 0.251 | 0.251 |
Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
None |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_3_WALL_NORTH |
PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_3_WALL_NORTH |
PERIMETER_BOT_ZN_2_WALL_EAST_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_2_WALL_EAST |
PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_1_WALL_SOUTH |
PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_1_WALL_SOUTH |
PERIMETER_BOT_ZN_4_WALL_WEST_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_4_WALL_WEST |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
Interior LightingZone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
CORE_BOTTOM_LIGHTS | CORE_BOTTOM | CORE_BOTTOM | GENERAL | 5.9322 | 983.54 | 5834.49 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 44.13 | 0.0000 | Y | 48.33 |
CORE_MID_LIGHTS | CORE_MID | CORE_MID | GENERAL | 5.9322 | 983.54 | 5834.49 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 44.13 | 0.0000 | Y | 48.33 |
CORE_TOP_LIGHTS | CORE_TOP | CORE_TOP | GENERAL | 5.9322 | 983.54 | 5834.49 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 44.13 | 0.0000 | Y | 48.33 |
PERIMETER_TOP_ZN_3_LIGHTS | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3 | GENERAL | 5.9322 | 207.34 | 1229.96 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 26.07 | 0.0000 | Y | 6.02 |
PERIMETER_TOP_ZN_2_LIGHTS | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2 | GENERAL | 5.9322 | 131.26 | 778.67 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 25.49 | 0.0000 | Y | 3.73 |
PERIMETER_TOP_ZN_1_LIGHTS | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1 | GENERAL | 5.9322 | 207.34 | 1229.96 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 25.26 | 0.0000 | Y | 5.83 |
PERIMETER_TOP_ZN_4_LIGHTS | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4 | GENERAL | 5.9322 | 131.25 | 778.62 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 25.83 | 0.0000 | Y | 3.78 |
PERIMETER_BOT_ZN_3_LIGHTS | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3 | GENERAL | 5.9322 | 207.34 | 1229.96 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 25.95 | 0.0000 | Y | 5.99 |
PERIMETER_BOT_ZN_2_LIGHTS | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2 | GENERAL | 5.9322 | 131.26 | 778.67 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 25.43 | 0.0000 | Y | 3.72 |
PERIMETER_BOT_ZN_1_LIGHTS | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1 | GENERAL | 5.9322 | 207.34 | 1229.96 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 25.20 | 0.0000 | Y | 5.82 |
PERIMETER_BOT_ZN_4_LIGHTS | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4 | GENERAL | 5.9322 | 131.25 | 778.62 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 25.75 | 0.0000 | Y | 3.76 |
PERIMETER_MID_ZN_3_LIGHTS | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3 | GENERAL | 5.9322 | 207.34 | 1229.96 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 26.07 | 0.0000 | Y | 6.02 |
PERIMETER_MID_ZN_2_LIGHTS | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2 | GENERAL | 5.9322 | 131.26 | 778.67 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 25.49 | 0.0000 | Y | 3.73 |
PERIMETER_MID_ZN_1_LIGHTS | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1 | GENERAL | 5.9322 | 207.34 | 1229.96 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 25.26 | 0.0000 | Y | 5.83 |
PERIMETER_MID_ZN_4_LIGHTS | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4 | GENERAL | 5.9322 | 131.25 | 778.62 | LightsWired | LTG_SCH_OFFICE | 45.30 | 168.00 | 25.83 | 0.0000 | Y | 3.78 |
Interior Lighting Total | 5.9322 | 4982.19 | 29555.08 | 202.99 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
PERIMETER_BOT_ZN_1_DAYLREFPT1 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 1229.96 | 471.69 |
PERIMETER_BOT_ZN_1_DAYLREFPT2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 1229.96 | 171.58 |
PERIMETER_BOT_ZN_2_DAYLREFPT1 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 778.67 | 298.62 |
PERIMETER_BOT_ZN_2_DAYLREFPT2 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 778.67 | 108.62 |
PERIMETER_BOT_ZN_3_DAYLREFPT1 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 1229.96 | 471.69 |
PERIMETER_BOT_ZN_3_DAYLREFPT2 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 1229.96 | 171.58 |
PERIMETER_BOT_ZN_4_DAYLREFPT1 | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 778.62 | 298.60 |
PERIMETER_BOT_ZN_4_DAYLREFPT2 | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 778.62 | 108.62 |
PERIMETER_MID_ZN_1_DAYLREFPT1 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 1229.96 | 471.69 |
PERIMETER_MID_ZN_1_DAYLREFPT2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 1229.96 | 171.58 |
PERIMETER_MID_ZN_2_DAYLREFPT1 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 778.67 | 298.62 |
PERIMETER_MID_ZN_2_DAYLREFPT2 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 778.67 | 108.62 |
PERIMETER_MID_ZN_3_DAYLREFPT1 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 1229.96 | 471.69 |
PERIMETER_MID_ZN_3_DAYLREFPT2 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 1229.96 | 171.58 |
PERIMETER_MID_ZN_4_DAYLREFPT1 | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 778.62 | 298.60 |
PERIMETER_MID_ZN_4_DAYLREFPT2 | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 778.62 | 108.62 |
PERIMETER_TOP_ZN_1_DAYLREFPT1 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 1229.96 | 471.69 |
PERIMETER_TOP_ZN_1_DAYLREFPT2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 1229.96 | 171.58 |
PERIMETER_TOP_ZN_2_DAYLREFPT1 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 778.67 | 298.62 |
PERIMETER_TOP_ZN_2_DAYLREFPT2 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 778.67 | 108.62 |
PERIMETER_TOP_ZN_3_DAYLREFPT1 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 1229.96 | 471.69 |
PERIMETER_TOP_ZN_3_DAYLREFPT2 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 1229.96 | 171.58 |
PERIMETER_TOP_ZN_4_DAYLREFPT1 | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 778.62 | 298.60 |
PERIMETER_TOP_ZN_4_DAYLREFPT2 | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 778.62 | 108.62 |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS_A | 424.83 | AstronomicalClock | - | 41.79 | 41.79 | 3.33 | |
EXTERIOR_LIGHTS_B | 408.47 | AstronomicalClock | - | 83.79 | 62.79 | 4.81 | |
EXTERIOR_LIGHTS_C | 4724.13 | AstronomicalClock | - | 83.79 | 47.06 | 41.73 | |
Exterior Lighting Total | 5557.43 | 49.88 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
Central PlantType | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | 106278.64 | 82487.46 | 23791.18 | 0.78 | 3.40 | |||
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | 94887.64 | 72369.31 | 22518.33 | 0.76 | 3.40 | |||
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed | 109004.23 | 85025.65 | 23978.58 | 0.78 | 3.40 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
PACU_VAV_BOT COOLING COIL | 105307.5 | 2.89 | 9.85 | N/A | N/A | 11.40 | |
PACU_VAV_MID COOLING COIL | 94146.7 | 2.90 | 9.90 | N/A | N/A | 11.47 | |
PACU_VAV_TOP COOLING COIL | 107968.3 | 2.88 | 9.83 | N/A | N/A | 11.38 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | ||||||||
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | ||||||||
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
CORE_BOTTOM VAV BOX REHEAT COIL | Coil:Heating:Electric | 24100.66 | 1.00 | |
CORE_MID VAV BOX REHEAT COIL | Coil:Heating:Electric | 23106.72 | 1.00 | |
CORE_TOP VAV BOX REHEAT COIL | Coil:Heating:Electric | 29302.32 | 1.00 | |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | 12586.62 | 1.00 | |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | 8259.18 | 1.00 | |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | 12629.82 | 1.00 | |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | 8223.72 | 1.00 | |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | 7884.40 | 1.00 | |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | 5266.07 | 1.00 | |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | 7939.44 | 1.00 | |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | 5229.76 | 1.00 | |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | 9349.74 | 1.00 | |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | 6204.11 | 1.00 | |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | 9391.00 | 1.00 | |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | 6168.84 | 1.00 | |
PACU_VAV_BOT HEATING COIL | Coil:Heating:Fuel | 12561.93 | 0.80 | |
PACU_VAV_MID HEATING COIL | Coil:Heating:Fuel | 14540.90 | 0.80 | |
PACU_VAV_TOP HEATING COIL | Coil:Heating:Fuel | 13322.17 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
PACU_VAV_BOT FAN | Fan:VariableVolume | 0.60 | 1314.72 | 5.31 | 11551.26 | 2174.89 | 1.00 | 1.14 | General | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 |
PACU_VAV_MID FAN | Fan:VariableVolume | 0.60 | 1314.72 | 4.58 | 10023.20 | 2189.01 | 1.00 | 1.14 | General | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:00:00 |
PACU_VAV_TOP FAN | Fan:VariableVolume | 0.60 | 1314.72 | 5.50 | 11959.62 | 2174.89 | 1.00 | 1.14 | General | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:00:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
SWHSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 3168.45 | 0.000054 | 0.73 | 13540.37 | 0.30 | General |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SWHSYS1 WATER HEATER | WaterHeater:Mixed | 0.38 | 29307.11 | 0.81 | 1.02 | 0.24 |
DX Cooling Coil Type | Assocated Fan | Net Cooling Capacity [W] | COP [W/W] | EER [Btu/W-h] | IEER [Btu/W-h] | Supply Air Flow 100% [kg/s] | COP 75% Capacity [W/W] | EER 75% Capacity [Btu/W-h] | Supply Air Flow 75% [kg/s] | COP 50% Capacity [W/W] | EER 50% Capacity [Btu/W-h] | Supply Air Flow 50% [kg/s] | COP 25% Capacity [W/W] | EER 25% Capacity [Btu/W-h] | Supply Air Flow 25% [kg/s] | |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | None | 105307.51 | 2.89 | 9.85 | 11.40 | 5.5769 | 3.27 | 11.14 | 4.4548 | 3.44 | 11.74 | 3.0006 | 3.60 | 12.30 | 1.2138 |
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | None | 94146.70 | 2.90 | 9.90 | 11.47 | 4.8079 | 3.29 | 11.21 | 3.8364 | 3.46 | 11.82 | 2.5832 | 3.62 | 12.34 | 1.0576 |
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed | None | 107968.33 | 2.88 | 9.83 | 11.38 | 5.7740 | 3.26 | 11.12 | 4.6146 | 3.43 | 11.71 | 3.1085 | 3.60 | 12.28 | 1.2525 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
CORE_BOTTOM | 37928.88 | 37928.88 | 38.56 | 3.011 | 3.011 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 24.00 | 24.00 | 0.00882 | 30.96 | 0.00562 | 0.425 | 0.00 |
CORE_MID | 27778.43 | 27778.43 | 28.24 | 2.203 | 2.203 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 24.00 | 24.00 | 0.00894 | 30.96 | 0.00562 | 0.425 | 0.00 |
CORE_TOP | 30266.49 | 30266.49 | 30.77 | 2.422 | 2.422 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 | 24.00 | 24.00 | 0.00890 | 40.27 | 0.00563 | 0.425 | 0.00 |
PERIMETER_TOP_ZN_3 | 10350.39 | 10350.39 | 49.92 | 0.828 | 0.828 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:30:00 | 24.00 | 24.00 | 0.00871 | 40.40 | 0.00563 | 0.090 | 0.00 |
PERIMETER_TOP_ZN_2 | 9282.63 | 9282.63 | 70.72 | 0.743 | 0.743 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:20:00 | 24.00 | 24.00 | 0.00865 | 36.41 | 0.00562 | 0.057 | 0.00 |
PERIMETER_TOP_ZN_1 | 11503.94 | 11503.94 | 55.48 | 0.921 | 0.921 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:20:00 | 24.00 | 24.00 | 0.00869 | 40.80 | 0.00563 | 0.090 | 0.00 |
PERIMETER_TOP_ZN_4 | 10534.37 | 10534.37 | 80.26 | 0.843 | 0.843 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 24.00 | 24.00 | 0.00863 | 38.94 | 0.00563 | 0.057 | 0.00 |
PERIMETER_BOT_ZN_3 | 8550.75 | 8550.75 | 41.24 | 0.684 | 0.684 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | 24.00 | 24.00 | 0.00877 | 40.67 | 0.00563 | 0.090 | 0.00 |
PERIMETER_BOT_ZN_2 | 8135.58 | 8135.58 | 61.98 | 0.651 | 0.651 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:20:00 | 24.00 | 24.00 | 0.00868 | 36.41 | 0.00562 | 0.057 | 0.00 |
PERIMETER_BOT_ZN_1 | 9555.45 | 9555.45 | 46.09 | 0.765 | 0.765 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 24.00 | 24.00 | 0.00875 | 40.80 | 0.00563 | 0.090 | 0.00 |
PERIMETER_BOT_ZN_4 | 8568.56 | 8568.56 | 65.28 | 0.686 | 0.686 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:10:00 | 24.00 | 24.00 | 0.00867 | 38.72 | 0.00563 | 0.057 | 0.00 |
PERIMETER_MID_ZN_3 | 8764.16 | 8764.16 | 42.27 | 0.701 | 0.701 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:20:00 | 24.00 | 24.00 | 0.00876 | 40.53 | 0.00563 | 0.090 | 0.00 |
PERIMETER_MID_ZN_2 | 8738.47 | 8738.47 | 66.57 | 0.699 | 0.699 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 10:00:00 | 24.00 | 24.00 | 0.00866 | 35.75 | 0.00562 | 0.057 | 0.00 |
PERIMETER_MID_ZN_1 | 9884.71 | 9884.71 | 47.67 | 0.791 | 0.791 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | 24.00 | 24.00 | 0.00873 | 40.80 | 0.00563 | 0.090 | 0.00 |
PERIMETER_MID_ZN_4 | 9317.55 | 9317.55 | 70.99 | 0.746 | 0.746 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 24.00 | 24.00 | 0.00865 | 38.94 | 0.00563 | 0.057 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
CORE_BOTTOM | 4259.16 | 4259.16 | 4.33 | 0.198 | 0.425 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00800 | 0.50 | 0.00432 | 0.425 | 0.00 |
CORE_MID | 11203.90 | 11203.90 | 11.39 | 0.521 | 0.521 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00800 | 0.50 | 0.00432 | 0.425 | 0.00 |
CORE_TOP | 20657.43 | 20657.43 | 21.00 | 0.966 | 0.966 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00800 | 0.50 | 0.00432 | 0.425 | 0.00 |
PERIMETER_TOP_ZN_3 | 8844.56 | 8844.56 | 42.66 | 0.415 | 0.415 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00796 | 0.50 | 0.00432 | 0.090 | 0.00 |
PERIMETER_TOP_ZN_2 | 5803.03 | 5803.03 | 44.21 | 0.272 | 0.272 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00796 | 0.50 | 0.00432 | 0.057 | 0.00 |
PERIMETER_TOP_ZN_1 | 8874.81 | 8874.81 | 42.80 | 0.417 | 0.417 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00796 | 0.50 | 0.00432 | 0.090 | 0.00 |
PERIMETER_TOP_ZN_4 | 5778.19 | 5778.19 | 44.02 | 0.271 | 0.271 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00796 | 0.50 | 0.00432 | 0.057 | 0.00 |
PERIMETER_BOT_ZN_3 | 5549.38 | 5549.38 | 26.76 | 0.260 | 0.260 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00792 | 0.50 | 0.00432 | 0.090 | 0.00 |
PERIMETER_BOT_ZN_2 | 3705.60 | 3705.60 | 28.23 | 0.174 | 0.174 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00793 | 0.50 | 0.00432 | 0.057 | 0.00 |
PERIMETER_BOT_ZN_1 | 5587.94 | 5587.94 | 26.95 | 0.262 | 0.262 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00792 | 0.50 | 0.00432 | 0.090 | 0.00 |
PERIMETER_BOT_ZN_4 | 3680.16 | 3680.16 | 28.04 | 0.172 | 0.172 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00792 | 0.50 | 0.00432 | 0.057 | 0.00 |
PERIMETER_MID_ZN_3 | 6577.11 | 6577.11 | 31.72 | 0.308 | 0.308 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00793 | 0.50 | 0.00432 | 0.090 | 0.00 |
PERIMETER_MID_ZN_2 | 4363.47 | 4363.47 | 33.24 | 0.205 | 0.205 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00793 | 0.50 | 0.00432 | 0.057 | 0.00 |
PERIMETER_MID_ZN_1 | 6606.03 | 6606.03 | 31.86 | 0.310 | 0.310 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00793 | 0.50 | 0.00432 | 0.090 | 0.00 |
PERIMETER_MID_ZN_4 | 4338.77 | 4338.77 | 33.06 | 0.203 | 0.203 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00793 | 0.50 | 0.00432 | 0.057 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PACU_VAV_BOT | 5.31 | 5.31 | 1.29 | 1.29 | 5.3112 | 1.3973 | 5.3112 | 0.2631 | 0.3000 |
PACU_VAV_MID | 4.58 | 4.58 | 1.55 | 1.55 | 4.5789 | 1.5473 | 4.5789 | 0.3379 | 0.3000 |
PACU_VAV_TOP | 5.50 | 5.50 | 2.34 | 2.34 | 5.4990 | 2.3417 | 5.4990 | 0.4258 | 0.3000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
CORE_BOTTOM VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_BOTTOM VAV BOX | 24100.661 | 24100.661 | -999.0 | -999.0 | -999.000 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 24100.66 | 12877.06 | 0.424691 | 12.80 | 10.74 | 0.00800000 | 40.00 | 20.06 | 0.00800000 | 0.50 | 0.00431558 | 0.50 | 0.0000 | 21.00 | 0.00799998 | 46.9511 | 4259.16 | 0.00 | -999.00 | -999.00 |
CORE_MID VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_MID VAV BOX | 23106.719 | 23106.719 | -999.0 | -999.0 | -999.000 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 23106.72 | 15801.28 | 0.521133 | 12.80 | 10.74 | 0.00800000 | 40.00 | 20.06 | 0.00800000 | 0.50 | 0.00431558 | 0.50 | 0.0000 | 21.00 | 0.00800000 | 46.9512 | 11203.90 | 0.00 | -999.00 | -999.00 |
CORE_TOP VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_TOP VAV BOX | 29302.324 | 29302.324 | -999.0 | -999.0 | -999.000 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 29302.32 | 29302.32 | 0.966403 | 12.80 | 10.74 | 0.00800000 | 40.00 | 20.06 | 0.00800000 | 0.50 | 0.00431558 | 0.50 | 0.0000 | 21.00 | 0.00800000 | 46.9512 | 20657.43 | 0.00 | -999.00 | -999.00 |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_3 VAV BOX | 12586.619 | 12586.619 | -999.0 | -999.0 | -999.000 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 12586.62 | 12586.62 | 0.415112 | 12.80 | 10.74 | 0.00800000 | 40.00 | 20.06 | 0.00800000 | 0.50 | 0.00431558 | 0.50 | 0.0000 | 21.00 | 0.00795553 | 46.6941 | 8844.56 | 0.00 | -999.00 | -999.00 |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_2 VAV BOX | 8259.181 | 8259.181 | -999.0 | -999.0 | -999.000 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 8259.18 | 8259.18 | 0.272391 | 12.80 | 10.74 | 0.00800000 | 40.00 | 20.06 | 0.00800000 | 0.50 | 0.00431558 | 0.50 | 0.0000 | 21.00 | 0.00795616 | 46.6977 | 5803.03 | 0.00 | -999.00 | -999.00 |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_1 VAV BOX | 12629.815 | 12629.815 | -999.0 | -999.0 | -999.000 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 12629.82 | 12629.82 | 0.416537 | 12.80 | 10.74 | 0.00800000 | 40.00 | 20.06 | 0.00800000 | 0.50 | 0.00431558 | 0.50 | 0.0000 | 21.00 | 0.00795584 | 46.6958 | 8874.81 | 0.00 | -999.00 | -999.00 |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_4 VAV BOX | 8223.716 | 8223.716 | -999.0 | -999.0 | -999.000 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 8223.72 | 8223.72 | 0.271222 | 12.80 | 10.74 | 0.00800000 | 40.00 | 20.06 | 0.00800000 | 0.50 | 0.00431558 | 0.50 | 0.0000 | 21.00 | 0.00795581 | 46.6957 | 5778.19 | 0.00 | -999.00 | -999.00 |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_3 VAV BOX | 7884.395 | 7884.395 | -999.0 | -999.0 | -999.000 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 7884.40 | 7884.40 | 0.260031 | 12.80 | 10.74 | 0.00800000 | 40.00 | 20.06 | 0.00800000 | 0.50 | 0.00431558 | 0.50 | 0.0000 | 21.00 | 0.00792140 | 46.4965 | 5549.38 | 0.00 | -999.00 | -999.00 |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_2 VAV BOX | 5266.073 | 5266.073 | -999.0 | -999.0 | -999.000 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 5266.07 | 5266.07 | 0.173677 | 12.80 | 10.74 | 0.00800000 | 40.00 | 20.06 | 0.00800000 | 0.50 | 0.00431558 | 0.50 | 0.0000 | 21.00 | 0.00792589 | 46.5225 | 3705.60 | 0.00 | -999.00 | -999.00 |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_1 VAV BOX | 7939.444 | 7939.444 | -999.0 | -999.0 | -999.000 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 7939.44 | 7939.44 | 0.261846 | 12.80 | 10.74 | 0.00800000 | 40.00 | 20.06 | 0.00800000 | 0.50 | 0.00431558 | 0.50 | 0.0000 | 21.00 | 0.00792259 | 46.5033 | 5587.94 | 0.00 | -999.00 | -999.00 |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_4 VAV BOX | 5229.763 | 5229.763 | -999.0 | -999.0 | -999.000 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 5229.76 | 5229.76 | 0.172480 | 12.80 | 10.74 | 0.00800000 | 40.00 | 20.06 | 0.00800000 | 0.50 | 0.00431558 | 0.50 | 0.0000 | 21.00 | 0.00792463 | 46.5151 | 3680.16 | 0.00 | -999.00 | -999.00 |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_3 VAV BOX | 9349.739 | 9349.739 | -999.0 | -999.0 | -999.000 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 9349.74 | 9349.74 | 0.308358 | 12.80 | 10.74 | 0.00800000 | 40.00 | 20.06 | 0.00800000 | 0.50 | 0.00431558 | 0.50 | 0.0000 | 21.00 | 0.00792512 | 46.5181 | 6577.11 | 0.00 | -999.00 | -999.00 |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_2 VAV BOX | 6204.111 | 6204.111 | -999.0 | -999.0 | -999.000 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 6204.11 | 6204.11 | 0.204614 | 12.80 | 10.74 | 0.00800000 | 40.00 | 20.06 | 0.00800000 | 0.50 | 0.00431558 | 0.50 | 0.0000 | 21.00 | 0.00792889 | 46.5399 | 4363.47 | 0.00 | -999.00 | -999.00 |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_1 VAV BOX | 9390.996 | 9390.996 | -999.0 | -999.0 | -999.000 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 9391.00 | 9391.00 | 0.309719 | 12.80 | 10.74 | 0.00800000 | 40.00 | 20.06 | 0.00800000 | 0.50 | 0.00431558 | 0.50 | 0.0000 | 21.00 | 0.00792587 | 46.5224 | 6606.03 | 0.00 | -999.00 | -999.00 |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_4 VAV BOX | 6168.841 | 6168.841 | -999.0 | -999.0 | -999.000 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 6168.84 | 6168.84 | 0.203451 | 12.80 | 10.74 | 0.00800000 | 40.00 | 20.06 | 0.00800000 | 0.50 | 0.00431558 | 0.50 | 0.0000 | 21.00 | 0.00792798 | 46.5346 | 4338.77 | 0.00 | -999.00 | -999.00 |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoopHVAC | PACU_VAV_BOT | 106278.637 | 82487.458 | 5.311196 | -999.0 | -999.000 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 | 96892.78 | 96892.78 | 5.311196 | 27.79 | 16.34 | 0.00808298 | 10.85 | 10.02 | 0.00808298 | 40.80 | 0.00563111 | 18.58 | 22.5028 | 24.00 | 0.00879673 | 42.9725 | 66234.10 | 0.00 | 109587.54 | 79928.90 |
PACU_VAV_BOT HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PACU_VAV_BOT | 12561.929 | 12561.929 | -999.0 | -999.0 | -999.000 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 09:30:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 12561.93 | 12561.93 | 1.593359 | 5.62 | 4.42 | 0.00523000 | 12.80 | 10.74 | 0.00800000 | 0.50 | 0.00431558 | 0.50 | 75.0095 | 21.00 | 0.00796764 | 46.7640 | 19892.81 | 0.00 | -999.00 | -999.00 |
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoopHVAC | PACU_VAV_MID | 94887.640 | 72369.306 | 4.578870 | -999.0 | -999.000 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:00:00 | 86507.76 | 86507.76 | 4.578870 | 28.41 | 16.48 | 0.00799687 | 10.84 | 9.92 | 0.00799687 | 40.80 | 0.00563111 | 18.58 | 26.1019 | 24.00 | 0.00883978 | 43.1797 | 56847.90 | 0.00 | 97841.89 | 70244.53 |
PACU_VAV_MID HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PACU_VAV_MID | 14540.897 | 14540.897 | -999.0 | -999.0 | -999.000 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 14:50:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 14540.90 | 14540.90 | 1.373661 | 3.16 | 2.60 | 0.00478969 | 12.80 | 10.74 | 0.00800000 | 0.50 | 0.00431558 | 0.50 | 87.0062 | 21.00 | 0.00796237 | 46.7334 | 24038.13 | 0.00 | -999.00 | -999.00 |
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoopHVAC | PACU_VAV_TOP | 109004.229 | 85025.651 | 5.498957 | -999.0 | -999.000 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:00:00 | 99526.21 | 99526.21 | 5.498957 | 27.65 | 16.30 | 0.00809147 | 10.85 | 10.03 | 0.00809147 | 40.67 | 0.00563090 | 18.54 | 21.7345 | 24.00 | 0.00878058 | 42.8945 | 68257.69 | 0.00 | 112397.99 | 82344.11 |
PACU_VAV_TOP HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PACU_VAV_TOP | 13322.173 | 13322.173 | -999.0 | -999.0 | -999.000 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 06:30:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 13322.17 | 13322.17 | 1.649687 | 5.45 | 4.43 | 0.00530729 | 12.80 | 10.74 | 0.00800000 | 0.50 | 0.00431558 | 0.50 | 72.4483 | 19.60 | 0.00790920 | 50.6214 | 27293.09 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
CORE_BOTTOM VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_BOTTOM VAV BOX | CORE_BOTTOM | N/A | N/A | N/A | Yes | No | unknown | No | 24100.661 | 24100.661 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0932 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 24100.66 | 12877.06 | 1.0000 | 0.46426985 | 0.424691 | 12.80 | 10.74 | 0.00800000 | 33059.8 | 40.00 | 20.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 24100.66 | 0.50 | 0.00431558 | 0.50 | 0.00000000 | 0.0000 | 20.74 | 0.00799998 | 21.00 | 0.00799998 | 46.9511 | 4259.16 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
CORE_MID VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_MID VAV BOX | CORE_MID | N/A | N/A | N/A | Yes | No | unknown | No | 23106.719 | 23106.719 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0932 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 23106.72 | 15801.28 | 1.0000 | 0.56969982 | 0.521133 | 12.80 | 10.74 | 0.00800000 | 33059.8 | 40.00 | 20.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 23106.72 | 0.50 | 0.00431558 | 0.50 | 0.00000000 | 0.0000 | 20.87 | 0.00800000 | 21.00 | 0.00800000 | 46.9512 | 11203.90 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
CORE_TOP VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_TOP VAV BOX | CORE_TOP | N/A | N/A | N/A | Yes | No | unknown | No | 29302.324 | 29302.324 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0932 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 29302.32 | 29302.32 | 1.0000 | 1.05646668 | 0.966403 | 12.80 | 10.74 | 0.00800000 | 33059.8 | 40.00 | 20.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 29302.32 | 0.50 | 0.00431558 | 0.50 | 0.00000000 | 0.0000 | 20.91 | 0.00800000 | 21.00 | 0.00800000 | 46.9512 | 20657.43 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_3 VAV BOX | PERIMETER_TOP_ZN_3 | N/A | N/A | N/A | Yes | No | unknown | No | 12586.619 | 12586.619 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0932 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 12586.62 | 12586.62 | 1.0000 | 0.45379824 | 0.415112 | 12.80 | 10.74 | 0.00800000 | 33059.8 | 40.00 | 20.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12586.62 | 0.50 | 0.00431558 | 0.50 | 0.00000000 | 0.0000 | 20.95 | 0.00795553 | 21.00 | 0.00795553 | 46.6941 | 8844.56 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_2 VAV BOX | PERIMETER_TOP_ZN_2 | N/A | N/A | N/A | Yes | No | unknown | No | 8259.181 | 8259.181 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0932 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 8259.18 | 8259.18 | 1.0000 | 0.29777669 | 0.272391 | 12.80 | 10.74 | 0.00800000 | 33059.8 | 40.00 | 20.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8259.18 | 0.50 | 0.00431558 | 0.50 | 0.00000000 | 0.0000 | 20.95 | 0.00795616 | 21.00 | 0.00795616 | 46.6977 | 5803.03 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_1 VAV BOX | PERIMETER_TOP_ZN_1 | N/A | N/A | N/A | Yes | No | unknown | No | 12629.815 | 12629.815 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0932 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 12629.82 | 12629.82 | 1.0000 | 0.45535565 | 0.416537 | 12.80 | 10.74 | 0.00800000 | 33059.8 | 40.00 | 20.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12629.82 | 0.50 | 0.00431558 | 0.50 | 0.00000000 | 0.0000 | 20.95 | 0.00795584 | 21.00 | 0.00795584 | 46.6958 | 8874.81 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_4 VAV BOX | PERIMETER_TOP_ZN_4 | N/A | N/A | N/A | Yes | No | unknown | No | 8223.716 | 8223.716 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0932 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 8223.72 | 8223.72 | 1.0000 | 0.29649805 | 0.271222 | 12.80 | 10.74 | 0.00800000 | 33059.8 | 40.00 | 20.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8223.72 | 0.50 | 0.00431558 | 0.50 | 0.00000000 | 0.0000 | 20.95 | 0.00795581 | 21.00 | 0.00795581 | 46.6957 | 5778.19 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_3 VAV BOX | PERIMETER_BOT_ZN_3 | N/A | N/A | N/A | Yes | No | unknown | No | 7884.395 | 7884.395 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0932 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 7884.40 | 7884.40 | 1.0000 | 0.28426417 | 0.260031 | 12.80 | 10.74 | 0.00800000 | 33059.8 | 40.00 | 20.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7884.40 | 0.50 | 0.00431558 | 0.50 | 0.00000000 | 0.0000 | 20.91 | 0.00792140 | 21.00 | 0.00792140 | 46.4965 | 5549.38 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_2 VAV BOX | PERIMETER_BOT_ZN_2 | N/A | N/A | N/A | Yes | No | unknown | No | 5266.073 | 5266.073 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0932 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 5266.07 | 5266.07 | 1.0000 | 0.18986312 | 0.173677 | 12.80 | 10.74 | 0.00800000 | 33059.8 | 40.00 | 20.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5266.07 | 0.50 | 0.00431558 | 0.50 | 0.00000000 | 0.0000 | 20.91 | 0.00792589 | 21.00 | 0.00792589 | 46.5225 | 3705.60 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_1 VAV BOX | PERIMETER_BOT_ZN_1 | N/A | N/A | N/A | Yes | No | unknown | No | 7939.444 | 7939.444 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0932 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 7939.44 | 7939.44 | 1.0000 | 0.28624888 | 0.261846 | 12.80 | 10.74 | 0.00800000 | 33059.8 | 40.00 | 20.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7939.44 | 0.50 | 0.00431558 | 0.50 | 0.00000000 | 0.0000 | 20.91 | 0.00792259 | 21.00 | 0.00792259 | 46.5033 | 5587.94 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_4 VAV BOX | PERIMETER_BOT_ZN_4 | N/A | N/A | N/A | Yes | No | unknown | No | 5229.763 | 5229.763 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0932 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 5229.76 | 5229.76 | 1.0000 | 0.18855401 | 0.172480 | 12.80 | 10.74 | 0.00800000 | 33059.8 | 40.00 | 20.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 5229.76 | 0.50 | 0.00431558 | 0.50 | 0.00000000 | 0.0000 | 20.91 | 0.00792463 | 21.00 | 0.00792463 | 46.5151 | 3680.16 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_3 VAV BOX | PERIMETER_MID_ZN_3 | N/A | N/A | N/A | Yes | No | unknown | No | 9349.739 | 9349.739 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0932 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 9349.74 | 9349.74 | 1.0000 | 0.33709570 | 0.308358 | 12.80 | 10.74 | 0.00800000 | 33059.8 | 40.00 | 20.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9349.74 | 0.50 | 0.00431558 | 0.50 | 0.00000000 | 0.0000 | 20.91 | 0.00792512 | 21.00 | 0.00792512 | 46.5181 | 6577.11 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_2 VAV BOX | PERIMETER_MID_ZN_2 | N/A | N/A | N/A | Yes | No | unknown | No | 6204.111 | 6204.111 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0932 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 6204.11 | 6204.11 | 1.0000 | 0.22368318 | 0.204614 | 12.80 | 10.74 | 0.00800000 | 33059.8 | 40.00 | 20.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6204.11 | 0.50 | 0.00431558 | 0.50 | 0.00000000 | 0.0000 | 20.95 | 0.00792889 | 21.00 | 0.00792889 | 46.5399 | 4363.47 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_1 VAV BOX | PERIMETER_MID_ZN_1 | N/A | N/A | N/A | Yes | No | unknown | No | 9390.996 | 9390.996 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0932 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 9391.00 | 9391.00 | 1.0000 | 0.33858321 | 0.309719 | 12.80 | 10.74 | 0.00800000 | 33059.8 | 40.00 | 20.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9391.00 | 0.50 | 0.00431558 | 0.50 | 0.00000000 | 0.0000 | 20.91 | 0.00792587 | 21.00 | 0.00792587 | 46.5224 | 6606.03 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_4 VAV BOX | PERIMETER_MID_ZN_4 | N/A | N/A | N/A | Yes | No | unknown | No | 6168.841 | 6168.841 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0932 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 6168.84 | 6168.84 | 1.0000 | 0.22241152 | 0.203451 | 12.80 | 10.74 | 0.00800000 | 33059.8 | 40.00 | 20.06 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 6168.84 | 0.50 | 0.00431558 | 0.50 | 0.00000000 | 0.0000 | 20.95 | 0.00792798 | 21.00 | 0.00792798 | 46.5346 | 4338.77 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoop | AirLoopHVAC | PACU_VAV_BOT | CORE_BOTTOM; PERIMETER_BOT_ZN_1; PERIMETER_BOT_ZN_2; PERIMETER_BOT_ZN_3; PERIMETER_BOT_ZN_4; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 106278.637 | 82487.458 | 5.311196 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.8658 | 1004.8586 | 1.0932 | PACU_VAV_BOT FAN | Fan:VariableVolume | 5.311196 | 5.80616914 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:40:00 | Sensible | 96892.78 | 96892.78 | 0.9117 | 5.80616914 | 5.311196 | 27.79 | 16.34 | 0.00808298 | 48554.0 | 10.85 | 10.02 | 0.00808298 | 31279.8 | -999.0 | -999.00 | -999.00 | -999.00 | 11551.259 | 85341.52 | 40.80 | 0.00563111 | 18.58 | 1.19517000 | 22.5028 | 24.00 | 0.00879673 | 24.00 | 0.00879673 | 42.9725 | 66234.10 | 0.00 | 109587.54 | 79928.90 | 5.57686935 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 12.64 | 12.63 | 0.00909953 | 35672.0 | |
PACU_VAV_BOT HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PACU_VAV_BOT | CORE_BOTTOM; PERIMETER_BOT_ZN_1; PERIMETER_BOT_ZN_2; PERIMETER_BOT_ZN_3; PERIMETER_BOT_ZN_4; | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 12561.929 | 12561.929 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0932 | PACU_VAV_BOT FAN | Fan:VariableVolume | 5.311196 | 5.80616914 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 09:30:00 | unknown | unknown | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 12561.93 | 12561.93 | 1.0000 | 1.74185074 | 1.593359 | 5.62 | 4.42 | 0.00523000 | 18784.8 | 12.80 | 10.74 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12561.93 | 0.50 | 0.00431558 | 0.50 | 1.19517000 | 75.0095 | 21.00 | 0.00797462 | 21.00 | 0.00796764 | 46.7640 | 19892.81 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoop | AirLoopHVAC | PACU_VAV_MID | CORE_MID; PERIMETER_MID_ZN_1; PERIMETER_MID_ZN_2; PERIMETER_MID_ZN_3; PERIMETER_MID_ZN_4; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 94887.640 | 72369.306 | 4.578870 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7058 | 1004.8586 | 1.0932 | PACU_VAV_MID FAN | Fan:VariableVolume | 4.578870 | 5.00559429 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:00:00 | Sensible | 86507.76 | 86507.76 | 0.9117 | 5.00559429 | 4.578870 | 28.41 | 16.48 | 0.00799687 | 48972.1 | 10.84 | 9.92 | 0.00799687 | 31049.5 | -999.0 | -999.00 | -999.00 | -999.00 | 10023.197 | 76484.56 | 40.80 | 0.00563111 | 18.58 | 1.19517000 | 26.1019 | 24.00 | 0.00883978 | 24.00 | 0.00883978 | 43.1797 | 56847.90 | 0.00 | 97841.89 | 70244.53 | 4.80791116 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 12.36 | 12.35 | 0.00893414 | 34972.2 | |
PACU_VAV_MID HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PACU_VAV_MID | CORE_MID; PERIMETER_MID_ZN_1; PERIMETER_MID_ZN_2; PERIMETER_MID_ZN_3; PERIMETER_MID_ZN_4; | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 14540.897 | 14540.897 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0932 | PACU_VAV_MID FAN | Fan:VariableVolume | 4.578870 | 5.00559429 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 14:50:00 | unknown | unknown | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 14540.90 | 14540.90 | 1.0000 | 1.50167829 | 1.373661 | 3.16 | 2.60 | 0.00478969 | 15185.9 | 12.80 | 10.74 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 14540.90 | 0.50 | 0.00431558 | 0.50 | 1.19517000 | 87.0062 | 21.00 | 0.00796428 | 21.00 | 0.00796237 | 46.7334 | 24038.13 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoop | AirLoopHVAC | PACU_VAV_TOP | CORE_TOP; PERIMETER_TOP_ZN_1; PERIMETER_TOP_ZN_2; PERIMETER_TOP_ZN_3; PERIMETER_TOP_ZN_4; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 109004.229 | 85025.651 | 5.498957 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.8816 | 1004.8586 | 1.0932 | PACU_VAV_TOP FAN | Fan:VariableVolume | 5.498957 | 6.01142766 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 16:00:00 | Sensible | 99526.21 | 99526.21 | 0.9130 | 6.01142766 | 5.498957 | 27.65 | 16.30 | 0.00809147 | 48431.6 | 10.85 | 10.03 | 0.00809147 | 31301.3 | -999.0 | -999.00 | -999.00 | -999.00 | 11959.617 | 87566.60 | 40.67 | 0.00563090 | 18.54 | 1.19517000 | 21.7345 | 24.00 | 0.00878058 | 24.00 | 0.00878058 | 42.8945 | 68257.69 | 0.00 | 112397.99 | 82344.11 | 5.77402171 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 12.71 | 12.70 | 0.00914389 | 35856.2 | |
PACU_VAV_TOP HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PACU_VAV_TOP | CORE_TOP; PERIMETER_TOP_ZN_1; PERIMETER_TOP_ZN_2; PERIMETER_TOP_ZN_3; PERIMETER_TOP_ZN_4; | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 13322.173 | 13322.173 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0932 | PACU_VAV_TOP FAN | Fan:VariableVolume | 5.498957 | 6.01142766 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 06:30:00 | unknown | unknown | TUCSON-DAVIS-MONTHAN.AFB_AZ_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 13322.17 | 13322.17 | 1.0000 | 1.80342830 | 1.649687 | 5.45 | 4.43 | 0.00530729 | 18801.9 | 12.80 | 10.74 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 13322.17 | 0.50 | 0.00431558 | 0.50 | 1.19517000 | 72.4483 | 18.46 | 0.00791501 | 19.60 | 0.00790920 | 50.6214 | 27293.09 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
PACU_VAV_BOT_OA_CONTROLLER | DifferentialDryBulb | 0.00 | 5.31 | - | |||
PACU_VAV_MID_OA_CONTROLLER | DifferentialDryBulb | 0.00 | 4.58 | - | |||
PACU_VAV_TOP_OA_CONTROLLER | DifferentialDryBulb | 0.00 | 5.50 | - |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
CORE_BOTTOM | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
CORE_MID | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
CORE_TOP | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_3 | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_2 | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_1 | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_4 | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
CORE_BOTTOM | 1983.83 | 1281.33 | 2.33 |
CORE_MID | 1589.00 | 2526.50 | 14.00 |
CORE_TOP | 1655.67 | 2871.83 | 92.83 |
PERIMETER_TOP_ZN_3 | 2386.33 | 3045.67 | 558.67 |
PERIMETER_TOP_ZN_2 | 2777.00 | 2608.17 | 487.83 |
PERIMETER_TOP_ZN_1 | 2840.17 | 2098.00 | 392.50 |
PERIMETER_TOP_ZN_4 | 2734.00 | 2806.50 | 602.83 |
PERIMETER_BOT_ZN_3 | 1836.67 | 3035.17 | 117.17 |
PERIMETER_BOT_ZN_2 | 2448.33 | 2273.83 | 157.17 |
PERIMETER_BOT_ZN_1 | 2555.17 | 1995.67 | 244.33 |
PERIMETER_BOT_ZN_4 | 2374.50 | 2438.33 | 138.50 |
PERIMETER_MID_ZN_3 | 1968.67 | 2849.83 | 174.67 |
PERIMETER_MID_ZN_2 | 2106.50 | 2111.00 | 235.00 |
PERIMETER_MID_ZN_1 | 2649.50 | 1781.83 | 176.17 |
PERIMETER_MID_ZN_4 | 2440.83 | 2539.67 | 248.67 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 |
Facility | 4093.83 | 3691.00 | 919.33 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
CORE_BOTTOM | 0.00 | 2.17 | 0.00 | 0.00 |
CORE_MID | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 0.17 | 36.50 | 0.00 | 22.33 |
PERIMETER_TOP_ZN_2 | 0.00 | 72.33 | 0.00 | 62.67 |
PERIMETER_TOP_ZN_1 | 0.00 | 71.00 | 0.00 | 58.17 |
PERIMETER_TOP_ZN_4 | 0.00 | 63.50 | 0.00 | 33.67 |
PERIMETER_BOT_ZN_3 | 0.00 | 1.50 | 0.00 | 0.33 |
PERIMETER_BOT_ZN_2 | 0.00 | 53.17 | 0.00 | 48.33 |
PERIMETER_BOT_ZN_1 | 80.00 | 360.50 | 80.00 | 356.17 |
PERIMETER_BOT_ZN_4 | 0.00 | 47.17 | 0.00 | 24.83 |
PERIMETER_MID_ZN_3 | 0.00 | 15.00 | 0.00 | 9.00 |
PERIMETER_MID_ZN_2 | 0.00 | 56.17 | 0.00 | 52.67 |
PERIMETER_MID_ZN_1 | 0.00 | 59.67 | 0.00 | 53.83 |
PERIMETER_MID_ZN_4 | 0.00 | 50.83 | 0.00 | 27.83 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 80.17 | 559.00 | 80.00 | 504.67 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
CORE_BOTTOM | 22.03 | 52.94 | 2698.04 | 0.934 | 0.000 | 0.000 | 0.000 |
CORE_MID | 22.03 | 52.94 | 2698.04 | 0.632 | 0.000 | 0.000 | 0.000 |
CORE_TOP | 22.03 | 52.94 | 2698.04 | 0.615 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_3 | 4.64 | 11.16 | 568.77 | 0.705 | 0.017 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_2 | 2.94 | 7.07 | 360.08 | 1.108 | 0.018 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_1 | 4.64 | 11.16 | 568.77 | 1.193 | 0.017 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_4 | 2.94 | 7.06 | 360.05 | 1.135 | 0.018 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_3 | 4.64 | 11.16 | 568.77 | 0.663 | 0.009 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_2 | 2.94 | 7.07 | 360.08 | 1.031 | 0.009 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_1 | 4.64 | 11.16 | 568.77 | 1.067 | 1.252 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_4 | 2.94 | 7.06 | 360.05 | 0.971 | 0.009 | 0.000 | 0.000 |
PERIMETER_MID_ZN_3 | 4.64 | 11.16 | 568.77 | 0.708 | 0.014 | 0.000 | 0.000 |
PERIMETER_MID_ZN_2 | 2.58 | 7.07 | 360.08 | 1.054 | 0.016 | 0.000 | 0.000 |
PERIMETER_MID_ZN_1 | 4.64 | 11.16 | 568.77 | 1.173 | 0.014 | 0.000 | 0.000 |
PERIMETER_MID_ZN_4 | 2.94 | 7.06 | 360.05 | 1.084 | 0.015 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
CORE_BOTTOM | 22.03 | 52.94 | 2698.04 | 0.000 | 0.000 | 0.000 | 0.000 |
CORE_MID | 22.03 | 52.94 | 2698.04 | 0.000 | 0.000 | 0.000 | 0.000 |
CORE_TOP | 22.03 | 52.94 | 2698.04 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_3 | 4.64 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_2 | 2.94 | 7.07 | 360.08 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_1 | 4.64 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_4 | 2.94 | 7.06 | 360.05 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_3 | 4.64 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_2 | 2.94 | 7.07 | 360.08 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_1 | 4.64 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_4 | 2.94 | 7.06 | 360.05 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_3 | 4.64 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_2 | 2.58 | 7.07 | 360.08 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_1 | 4.64 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_4 | 2.94 | 7.06 | 360.05 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
Mechanical Ventilation Parameters by ZoneAirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
CORE_BOTTOM | PACU_VAV_BOT | 22.03 | 52.94 | 2698.04 | 983.54 | 0.0000 | 0.425 |
CORE_MID | PACU_VAV_MID | 22.03 | 52.94 | 2698.04 | 983.54 | 0.0000 | 0.425 |
CORE_TOP | PACU_VAV_TOP | 22.03 | 52.94 | 2698.04 | 983.54 | 0.0000 | 0.425 |
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP | 4.64 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP | 2.94 | 7.07 | 360.08 | 131.26 | 0.0000 | 0.057 |
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP | 4.64 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP | 2.94 | 7.06 | 360.05 | 131.25 | 0.0000 | 0.057 |
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT | 4.64 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT | 2.94 | 7.07 | 360.08 | 131.26 | 0.0000 | 0.057 |
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT | 4.64 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT | 2.94 | 7.06 | 360.05 | 131.25 | 0.0000 | 0.057 |
PERIMETER_MID_ZN_3 | PACU_VAV_MID | 4.64 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_MID_ZN_2 | PACU_VAV_MID | 2.58 | 7.07 | 360.08 | 131.26 | 0.0000 | 0.057 |
PERIMETER_MID_ZN_1 | PACU_VAV_MID | 4.64 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_MID_ZN_4 | PACU_VAV_MID | 2.94 | 7.06 | 360.05 | 131.25 | 0.0000 | 0.057 |
Total Facility | 111.24 | 268.17 | 13667.13 | 4982.19 | 0.0000 | 2.151 |
Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
CORE_BOTTOM | 15040339.73 | 0.00 | 15040339.73 | 0.00 | 15040339.73 | 13393058.27 | 5752.91 | 72.99 | 2934.10 | 109.48 |
CORE_MID | 10096048.64 | 0.00 | 10096048.64 | 0.00 | 10096048.64 | 13393058.27 | 6392.06 | 15.36 | 2352.58 | 51.15 |
CORE_TOP | 9780988.21 | 0.00 | 9780988.21 | 0.00 | 9780988.21 | 13393058.27 | 6456.09 | 10.91 | 2293.00 | 33.62 |
PERIMETER_TOP_ZN_3 | 2359155.17 | 0.00 | 2359155.17 | 111665.70 | 2470820.87 | 2823374.22 | 4530.55 | 41.70 | 4187.75 | 33.62 |
PERIMETER_TOP_ZN_2 | 2344798.38 | 0.00 | 2344798.38 | 74443.35 | 2419241.74 | 1787429.43 | 4070.84 | 4.79 | 4684.37 | 33.62 |
PERIMETER_TOP_ZN_1 | 3979328.12 | 0.00 | 3979328.12 | 111665.70 | 4090993.82 | 2823374.22 | 4202.27 | 27.36 | 4530.37 | 33.62 |
PERIMETER_TOP_ZN_4 | 2407596.82 | 0.00 | 2407596.82 | 74443.35 | 2482040.18 | 1787312.18 | 4171.38 | 30.03 | 4558.60 | 33.62 |
PERIMETER_BOT_ZN_3 | 2266679.82 | 0.00 | 2266679.82 | 59372.45 | 2326052.27 | 2823374.22 | 5334.50 | 112.84 | 3312.66 | 109.48 |
PERIMETER_BOT_ZN_2 | 2216533.94 | 0.00 | 2216533.94 | 39581.39 | 2256115.33 | 1787429.43 | 4012.04 | 21.52 | 4726.44 | 109.48 |
PERIMETER_BOT_ZN_1 | 3609321.46 | 0.00 | 3609321.46 | 4183234.79 | 7792556.25 | 2823374.22 | 4200.22 | 37.27 | 4522.51 | 109.48 |
PERIMETER_BOT_ZN_4 | 2094797.33 | 0.00 | 2094797.33 | 39581.39 | 2134378.72 | 1787312.18 | 4370.41 | 66.35 | 4323.24 | 109.48 |
PERIMETER_MID_ZN_3 | 2378881.11 | 0.00 | 2378881.11 | 92953.43 | 2471834.54 | 2823374.22 | 4459.05 | 50.30 | 4250.65 | 51.15 |
PERIMETER_MID_ZN_2 | 2378555.56 | 0.00 | 2378555.56 | 61968.58 | 2440524.14 | 1787429.43 | 4019.78 | 7.67 | 4732.55 | 960.15 |
PERIMETER_MID_ZN_1 | 3919132.71 | 0.00 | 3919132.71 | 92953.43 | 4012086.13 | 2823374.22 | 4272.12 | 29.93 | 4457.96 | 51.15 |
PERIMETER_MID_ZN_4 | 2305450.30 | 0.00 | 2305450.30 | 61968.58 | 2367418.88 | 1787312.18 | 4097.64 | 27.52 | 4634.84 | 51.15 |
Total Facility | 67177607.30 | 0.00 | 67177607.30 | 5003832.15 | 72181439.45 | 67843644.98 | 6604.64 | 427.63 | 4883.94 | 1030.84 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
CORE_BOTTOM | 0.6860 | 0.0000 | 0.6860 | 0.0000 | 0.6860 | 0.4247 | 3045.40 | 72.99 | 2824.61 |
CORE_MID | 0.4645 | 0.0000 | 0.4645 | 0.0000 | 0.4645 | 0.4247 | 3626.21 | 15.36 | 2301.43 |
CORE_TOP | 0.4523 | 0.0000 | 0.4523 | 0.0000 | 0.4523 | 0.4247 | 3672.04 | 10.91 | 2260.05 |
PERIMETER_TOP_ZN_3 | 0.1093 | 0.0000 | 0.1093 | 0.0026 | 0.1119 | 0.0895 | 1746.50 | 41.70 | 4154.79 |
PERIMETER_TOP_ZN_2 | 0.1087 | 0.0000 | 0.1087 | 0.0017 | 0.1105 | 0.0567 | 1286.79 | 4.79 | 4651.42 |
PERIMETER_TOP_ZN_1 | 0.1849 | 0.0000 | 0.1849 | 0.0026 | 0.1875 | 0.0895 | 1418.22 | 27.36 | 4497.42 |
PERIMETER_TOP_ZN_4 | 0.1115 | 0.0000 | 0.1115 | 0.0017 | 0.1133 | 0.0567 | 1387.33 | 30.03 | 4525.64 |
PERIMETER_BOT_ZN_3 | 0.1028 | 0.0000 | 0.1028 | 0.0014 | 0.1042 | 0.0895 | 2626.99 | 112.84 | 3203.18 |
PERIMETER_BOT_ZN_2 | 0.1011 | 0.0000 | 0.1011 | 0.0009 | 0.1021 | 0.0567 | 1304.52 | 21.52 | 4616.95 |
PERIMETER_BOT_ZN_1 | 0.1654 | 0.0000 | 0.1654 | 0.1941 | 0.3596 | 0.0895 | 1492.71 | 37.27 | 4413.03 |
PERIMETER_BOT_ZN_4 | 0.0953 | 0.0000 | 0.0953 | 0.0009 | 0.0962 | 0.0567 | 1662.89 | 66.35 | 4213.76 |
PERIMETER_MID_ZN_3 | 0.1097 | 0.0000 | 0.1097 | 0.0022 | 0.1119 | 0.0895 | 1693.20 | 50.30 | 4199.50 |
PERIMETER_MID_ZN_2 | 0.1034 | 0.0000 | 0.1034 | 0.0016 | 0.1049 | 0.0567 | 1249.93 | 6.17 | 3777.90 |
PERIMETER_MID_ZN_1 | 0.1817 | 0.0000 | 0.1817 | 0.0022 | 0.1838 | 0.0895 | 1506.27 | 29.93 | 4406.80 |
PERIMETER_MID_ZN_4 | 0.1064 | 0.0000 | 0.1064 | 0.0014 | 0.1078 | 0.0567 | 1331.80 | 27.52 | 4583.68 |
Total Facility | 3.0831 | 0.0000 | 3.0831 | 0.2134 | 3.2965 | 2.1513 | 3810.44 | 427.63 | 4762.76 |
Mechanical Ventilation [m3] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
PACU_VAV_BOT | 30148927.60 | 0.00 | 30148927.60 | 22614548.33 | 3937.98 | 1.11 | 4820.91 | 109.48 |
PACU_VAV_MID | 25189858.19 | 0.00 | 25189858.19 | 22614548.33 | 4013.82 | 2.46 | 4743.72 | 51.15 |
PACU_VAV_TOP | 24943418.46 | 0.00 | 24943418.46 | 22614548.33 | 4082.66 | 5.35 | 4671.99 | 33.62 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
PACU_VAV_BOT | 1.3752 | 0.0000 | 1.3752 | 0.7171 | 1230.47 | 1.11 | 4711.42 |
PACU_VAV_MID | 1.1618 | 0.0000 | 1.1618 | 0.7171 | 1247.97 | 2.46 | 4692.57 |
PACU_VAV_TOP | 1.1553 | 0.0000 | 1.1553 | 0.7171 | 1298.61 | 5.35 | 4639.04 |
No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
PACU_VAV_BOT | 0.00 | 0.31 | 2616.31 | 0.00 | 0.00 | 0.00 | 2218.59 | 0.00 | 0.00 | 0.00 |
PACU_VAV_MID | 0.00 | 0.07 | 2445.31 | 0.00 | 0.00 | 0.00 | 2320.41 | 0.00 | 0.00 | 0.00 |
PACU_VAV_TOP | 0.00 | 0.00 | 2411.01 | 0.00 | 0.00 | 0.00 | 2325.04 | 0.00 | 0.00 | 0.00 |
No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
PACU_VAV_BOT | 0.0000 | 0.0000 | 2.4356 | 0.0000 | 0.0000 | 0.0000 | 0.9321 | 0.0000 | 0.0000 | 0.0000 |
PACU_VAV_MID | 0.0000 | 0.0000 | 1.9549 | 0.0000 | 0.0000 | 0.0000 | 0.9589 | 0.0000 | 0.0000 | 0.0000 |
PACU_VAV_TOP | 0.0000 | 0.0000 | 1.9659 | 0.0000 | 0.0000 | 0.0000 | 0.9432 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
Surfaces by ClassTotal | Outdoors | |
Wall | 72 | 24 |
Floor | 30 | 4 |
Roof | 26 | 1 |
Internal Mass | 15 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 18 | 18 |
Door | 6 | 6 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 3 |
Conditioned Zones | 18 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 3 |
Count | |
IDF Objects | 825 |
Defaulted Fields | 545 |
Fields with Defaults | 2230 |
Autosized Fields | 149 |
Autosizable Fields | 202 |
Autocalculated Fields | 155 |
Autocalculatable Fields | 276 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 1544.41 | 12347.20 | 30-JUL-17:40 | 172428.96 | 28-JUN-15:10 |
Electricity:Building | 908.42 | 12175.61 | 16-APR-17:10 | 66192.88 | 20-JAN-08:30 |
Electricity:Zone:CORE_BOTTOM | 284.50 | 4029.56 | 01-JAN-00:10 | 22405.39 | 02-JAN-08:10 |
Electricity:SpaceType:GENERAL | 908.42 | 12175.61 | 16-APR-17:10 | 66192.88 | 20-JAN-08:30 |
InteriorLights:Electricity | 202.99 | 934.27 | 01-JAN-10:30 | 21377.78 | 28-NOV-16:30 |
InteriorLights:Electricity:Zone:CORE_BOTTOM | 48.33 | 234.43 | 01-JAN-00:10 | 4220.20 | 02-JAN-08:10 |
InteriorLights:Electricity:SpaceType:GENERAL | 202.99 | 934.27 | 01-JAN-10:30 | 21377.78 | 28-NOV-16:30 |
LightsWired:InteriorLights:Electricity | 202.99 | 934.27 | 01-JAN-10:30 | 21377.78 | 28-NOV-16:30 |
LightsWired:InteriorLights:Electricity:Zone:CORE_BOTTOM | 48.33 | 234.43 | 01-JAN-00:10 | 4220.20 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:SpaceType:GENERAL | 202.99 | 934.27 | 01-JAN-10:30 | 21377.78 | 28-NOV-16:30 |
Electricity:Zone:CORE_MID | 163.76 | 2065.97 | 01-JAN-00:10 | 11028.52 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:CORE_MID | 48.33 | 234.43 | 01-JAN-00:10 | 4220.20 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:CORE_MID | 48.33 | 234.43 | 01-JAN-00:10 | 4220.20 | 02-JAN-08:10 |
Electricity:Zone:CORE_TOP | 163.76 | 2065.97 | 01-JAN-00:10 | 11028.52 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:CORE_TOP | 48.33 | 234.43 | 01-JAN-00:10 | 4220.20 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:CORE_TOP | 48.33 | 234.43 | 01-JAN-00:10 | 4220.20 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_TOP_ZN_3 | 30.35 | 409.68 | 02-APR-17:10 | 2324.90 | 28-NOV-16:30 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_3 | 6.02 | 23.57 | 01-JAN-10:30 | 889.66 | 28-NOV-16:30 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_3 | 6.02 | 23.57 | 01-JAN-10:30 | 889.66 | 28-NOV-16:30 |
Electricity:Zone:PERIMETER_TOP_ZN_2 | 19.13 | 259.34 | 16-APR-17:10 | 1471.80 | 28-NOV-16:30 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_2 | 3.73 | 14.92 | 01-JAN-08:00 | 563.23 | 28-NOV-16:30 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_2 | 3.73 | 14.92 | 01-JAN-08:00 | 563.23 | 28-NOV-16:30 |
Electricity:Zone:PERIMETER_TOP_ZN_1 | 30.16 | 409.67 | 02-APR-17:10 | 2324.89 | 28-NOV-16:30 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_1 | 5.83 | 23.57 | 01-JAN-08:10 | 889.66 | 28-NOV-16:30 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_1 | 5.83 | 23.57 | 01-JAN-08:10 | 889.66 | 28-NOV-16:30 |
Electricity:Zone:PERIMETER_TOP_ZN_4 | 19.18 | 259.34 | 12-MAR-17:10 | 1471.76 | 28-NOV-16:30 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_4 | 3.78 | 14.92 | 01-JAN-10:20 | 563.19 | 28-NOV-16:30 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_4 | 3.78 | 14.92 | 01-JAN-10:20 | 563.19 | 28-NOV-16:30 |
Electricity:Zone:PERIMETER_BOT_ZN_3 | 30.32 | 409.68 | 02-APR-17:10 | 2324.90 | 28-NOV-16:30 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_3 | 5.99 | 23.57 | 01-JAN-10:20 | 889.66 | 28-NOV-16:30 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_3 | 5.99 | 23.57 | 01-JAN-10:20 | 889.66 | 28-NOV-16:30 |
Electricity:Zone:PERIMETER_BOT_ZN_2 | 19.12 | 259.34 | 16-APR-17:10 | 1471.80 | 28-NOV-16:30 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_2 | 3.72 | 14.92 | 01-JAN-08:00 | 563.23 | 28-NOV-16:30 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_2 | 3.72 | 14.92 | 01-JAN-08:00 | 563.23 | 28-NOV-16:30 |
Electricity:Zone:PERIMETER_BOT_ZN_1 | 30.15 | 409.67 | 02-APR-17:10 | 2324.89 | 28-NOV-16:30 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_1 | 5.82 | 23.57 | 01-JAN-08:00 | 889.66 | 28-NOV-16:30 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_1 | 5.82 | 23.57 | 01-JAN-08:00 | 889.66 | 28-NOV-16:30 |
Electricity:Zone:PERIMETER_BOT_ZN_4 | 19.17 | 259.34 | 12-MAR-17:10 | 1471.76 | 28-NOV-16:30 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_4 | 3.76 | 14.92 | 01-JAN-10:10 | 563.19 | 28-NOV-16:30 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_4 | 3.76 | 14.92 | 01-JAN-10:10 | 563.19 | 28-NOV-16:30 |
Electricity:Zone:PERIMETER_MID_ZN_3 | 30.35 | 409.68 | 02-APR-17:10 | 2324.90 | 28-NOV-16:30 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_3 | 6.02 | 23.57 | 01-JAN-10:30 | 889.66 | 28-NOV-16:30 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_3 | 6.02 | 23.57 | 01-JAN-10:30 | 889.66 | 28-NOV-16:30 |
Electricity:Zone:PERIMETER_MID_ZN_2 | 19.13 | 259.34 | 16-APR-17:10 | 1471.80 | 28-NOV-16:30 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_2 | 3.73 | 14.92 | 01-JAN-08:00 | 563.23 | 28-NOV-16:30 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_2 | 3.73 | 14.92 | 01-JAN-08:00 | 563.23 | 28-NOV-16:30 |
Electricity:Zone:PERIMETER_MID_ZN_1 | 30.16 | 409.67 | 02-APR-17:10 | 2324.89 | 28-NOV-16:30 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_1 | 5.83 | 23.57 | 01-JAN-08:10 | 889.66 | 28-NOV-16:30 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_1 | 5.83 | 23.57 | 01-JAN-08:10 | 889.66 | 28-NOV-16:30 |
Electricity:Zone:PERIMETER_MID_ZN_4 | 19.18 | 259.34 | 12-MAR-17:10 | 1471.76 | 28-NOV-16:30 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_4 | 3.78 | 14.92 | 01-JAN-10:20 | 563.19 | 28-NOV-16:30 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_4 | 3.78 | 14.92 | 01-JAN-10:20 | 563.19 | 28-NOV-16:30 |
InteriorEquipment:Electricity | 705.43 | 11241.34 | 01-JAN-00:10 | 45864.70 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:CORE_BOTTOM | 236.17 | 3795.13 | 01-JAN-00:10 | 18185.19 | 02-JAN-08:10 |
InteriorEquipment:Electricity:SpaceType:GENERAL | 705.43 | 11241.34 | 01-JAN-00:10 | 45864.70 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity | 584.69 | 9277.75 | 01-JAN-00:10 | 34487.83 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_BOTTOM | 115.43 | 1831.54 | 01-JAN-00:10 | 6808.32 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL | 584.69 | 9277.75 | 01-JAN-00:10 | 34487.83 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:CORE_MID | 115.43 | 1831.54 | 01-JAN-00:10 | 6808.32 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_MID | 115.43 | 1831.54 | 01-JAN-00:10 | 6808.32 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:CORE_TOP | 115.43 | 1831.54 | 01-JAN-00:10 | 6808.32 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_TOP | 115.43 | 1831.54 | 01-JAN-00:10 | 6808.32 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
ElevatorLift:InteriorEquipment:Electricity | 120.10 | 1963.59 | 01-JAN-00:10 | 11290.62 | 02-JAN-08:10 |
ElevatorLift:InteriorEquipment:Electricity:Zone:CORE_BOTTOM | 120.10 | 1963.59 | 01-JAN-00:10 | 11290.62 | 02-JAN-08:10 |
ElevatorLift:InteriorEquipment:Electricity:SpaceType:GENERAL | 120.10 | 1963.59 | 01-JAN-00:10 | 11290.62 | 02-JAN-08:10 |
ElevatorLightsFan:InteriorEquipment:Electricity | 0.64 | 0.00 | 01-JAN-00:10 | 86.25 | 02-JAN-08:10 |
ElevatorLightsFan:InteriorEquipment:Electricity:Zone:CORE_BOTTOM | 0.64 | 0.00 | 01-JAN-00:10 | 86.25 | 02-JAN-08:10 |
ElevatorLightsFan:InteriorEquipment:Electricity:SpaceType:GENERAL | 0.64 | 0.00 | 01-JAN-00:10 | 86.25 | 02-JAN-08:10 |
Electricity:HVAC | 586.09 | 168.34 | 01-JAN-00:10 | 114951.85 | 28-JUN-15:00 |
ExteriorEquipment:Electricity | 11.66 | 168.34 | 01-JAN-00:10 | 833.98 | 28-NOV-16:40 |
Transformer:ExteriorEquipment:Electricity | 11.66 | 168.34 | 01-JAN-00:10 | 833.98 | 28-NOV-16:40 |
ElectricityPurchased:Facility | 1544.41 | 12347.20 | 30-JUL-17:40 | 172428.96 | 28-JUN-15:10 |
ElectricityPurchased:Plant | 1544.41 | 12347.20 | 30-JUL-17:40 | 172428.96 | 28-JUN-15:10 |
Cogeneration:ElectricityPurchased | 1544.41 | 12347.20 | 30-JUL-17:40 | 172428.96 | 28-JUN-15:10 |
General:Cogeneration:ElectricityPurchased | 1544.41 | 12347.20 | 30-JUL-17:40 | 172428.96 | 28-JUN-15:10 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 1544.41 | 12347.20 | 30-JUL-17:40 | 172428.96 | 28-JUN-15:10 |
ElectricityNet:Plant | 1544.41 | 12347.20 | 30-JUL-17:40 | 172428.96 | 28-JUN-15:10 |
Cogeneration:ElectricityNet | 1544.41 | 12347.20 | 30-JUL-17:40 | 172428.96 | 28-JUN-15:10 |
General:Cogeneration:ElectricityNet | 1544.41 | 12347.20 | 30-JUL-17:40 | 172428.96 | 28-JUN-15:10 |
Heating:Electricity | 9.10 | 0.00 | 01-JAN-00:10 | 63809.45 | 02-JAN-07:10 |
General:Heating:Electricity | 9.10 | 0.00 | 01-JAN-00:10 | 63809.45 | 02-JAN-07:10 |
Fans:Electricity | 138.67 | 0.00 | 01-JAN-00:10 | 26643.77 | 19-JUN-15:00 |
General:Fans:Electricity | 138.67 | 0.00 | 01-JAN-00:10 | 26643.77 | 19-JUN-15:00 |
ExteriorLights:Electricity | 49.88 | 0.00 | 01-JAN-07:30 | 5557.43 | 01-JAN-06:10 |
General:ExteriorLights:Electricity | 49.88 | 0.00 | 01-JAN-07:30 | 5557.43 | 01-JAN-06:10 |
Cooling:Electricity | 426.67 | 0.00 | 01-JAN-00:10 | 89640.32 | 28-JUN-15:00 |
General:Cooling:Electricity | 426.67 | 0.00 | 01-JAN-00:10 | 89640.32 | 28-JUN-15:00 |
Electricity:Plant | 0.02 | 0.00 | 01-JAN-00:10 | 0.73 | 02-JAN-08:10 |
Pumps:Electricity | 0.02 | 0.00 | 01-JAN-00:10 | 0.73 | 02-JAN-08:10 |
General:Pumps:Electricity | 0.02 | 0.00 | 01-JAN-00:10 | 0.73 | 02-JAN-08:10 |
WIRED_LTG_ELECTRICITY | 5.70 | 0.00 | 01-JAN-00:10 | 600.72 | 28-NOV-16:40 |
WIRED_INT_EQUIP | 585.33 | 9277.75 | 01-JAN-00:10 | 34574.08 | 02-JAN-08:10 |
Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
NaturalGas:Facility | 97.41 | 1156.00 | 02-JAN-06:10 | 37715.62 | 05-DEC-07:20 |
NaturalGas:HVAC | 3.20 | 0.00 | 01-JAN-00:10 | 31102.98 | 06-DEC-07:10 |
Heating:NaturalGas | 3.20 | 0.00 | 01-JAN-00:10 | 31102.98 | 06-DEC-07:10 |
General:Heating:NaturalGas | 3.20 | 0.00 | 01-JAN-00:10 | 31102.98 | 06-DEC-07:10 |
NaturalGas:Plant | 94.21 | 1156.00 | 02-JAN-06:10 | 9062.51 | 02-FEB-12:10 |
WaterSystems:NaturalGas | 94.21 | 1156.00 | 02-JAN-06:10 | 9062.51 | 02-FEB-12:10 |
Water Heater:WaterSystems:NaturalGas | 94.21 | 1156.00 | 02-JAN-06:10 | 9062.51 | 02-FEB-12:10 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 01-FEB-12:10 |
Water:Plant | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 01-FEB-12:10 |
WaterSystems:Water | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 01-FEB-12:10 |
WaterUse:WaterSystems:Water | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 01-FEB-12:10 |
MainsWater:Facility | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 01-FEB-12:10 |
MainsWater:Plant | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 01-FEB-12:10 |
WaterSystems:MainsWater | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 01-FEB-12:10 |
WaterUse:WaterSystems:MainsWater | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 01-FEB-12:10 |
Water Heater:WaterSystems:Water | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:MainsWater | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
EnergyTransfer:Facility | 3006.48 | 0.00 | 01-JAN-00:10 | 409287.31 | 05-SEP-07:50 |
EnergyTransfer:Building | 1465.98 | 0.00 | 01-JAN-00:10 | 168730.24 | 14-AUG-15:30 |
EnergyTransfer:Zone:CORE_BOTTOM | 276.34 | 0.00 | 01-JAN-00:10 | 28284.48 | 05-SEP-07:20 |
Heating:EnergyTransfer | 12.69 | 0.00 | 01-JAN-00:10 | 52205.85 | 02-JAN-07:10 |
Heating:EnergyTransfer:Zone:CORE_BOTTOM | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer | 12.69 | 0.00 | 01-JAN-00:10 | 52205.85 | 02-JAN-07:10 |
General:Heating:EnergyTransfer:Zone:CORE_BOTTOM | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer | 1453.29 | 0.00 | 01-JAN-00:10 | 168730.24 | 14-AUG-15:30 |
Cooling:EnergyTransfer:Zone:CORE_BOTTOM | 276.34 | 0.00 | 01-JAN-00:10 | 28284.48 | 05-SEP-07:20 |
General:Cooling:EnergyTransfer | 1453.29 | 0.00 | 01-JAN-00:10 | 168730.24 | 14-AUG-15:30 |
General:Cooling:EnergyTransfer:Zone:CORE_BOTTOM | 276.34 | 0.00 | 01-JAN-00:10 | 28284.48 | 05-SEP-07:20 |
EnergyTransfer:Zone:TOPFLOOR_PLENUM | 67.57 | 0.00 | 01-JAN-00:10 | 12922.27 | 28-JUN-14:40 |
Heating:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 5.51 | 0.00 | 01-JAN-00:10 | 6546.53 | 07-DEC-07:10 |
General:Heating:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 5.51 | 0.00 | 01-JAN-00:10 | 6546.53 | 07-DEC-07:10 |
Cooling:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 62.06 | 0.00 | 01-JAN-00:10 | 12922.27 | 28-JUN-14:40 |
General:Cooling:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 62.06 | 0.00 | 01-JAN-00:10 | 12922.27 | 28-JUN-14:40 |
EnergyTransfer:Zone:MIDFLOOR_PLENUM | 33.62 | 0.00 | 01-JAN-00:10 | 5629.18 | 19-JUN-14:50 |
Heating:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 1.69 | 0.00 | 01-JAN-00:10 | 2203.89 | 02-JAN-11:40 |
General:Heating:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 1.69 | 0.00 | 01-JAN-00:10 | 2203.89 | 02-JAN-11:40 |
Cooling:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 31.93 | 0.00 | 01-JAN-00:10 | 5629.18 | 19-JUN-14:50 |
General:Cooling:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 31.93 | 0.00 | 01-JAN-00:10 | 5629.18 | 19-JUN-14:50 |
EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 38.61 | 0.00 | 01-JAN-00:10 | 5909.00 | 28-AUG-07:10 |
Heating:EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 0.66 | 0.00 | 01-JAN-00:10 | 1843.87 | 02-JAN-08:30 |
General:Heating:EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 0.66 | 0.00 | 01-JAN-00:10 | 1843.87 | 02-JAN-08:30 |
Cooling:EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 37.95 | 0.00 | 01-JAN-00:10 | 5909.00 | 28-AUG-07:10 |
General:Cooling:EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 37.95 | 0.00 | 01-JAN-00:10 | 5909.00 | 28-AUG-07:10 |
EnergyTransfer:Zone:CORE_MID | 185.75 | 0.00 | 01-JAN-00:10 | 19201.95 | 05-SEP-07:40 |
Heating:EnergyTransfer:Zone:CORE_MID | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Heating:EnergyTransfer:Zone:CORE_MID | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:CORE_MID | 185.75 | 0.00 | 01-JAN-00:10 | 19201.95 | 05-SEP-07:40 |
General:Cooling:EnergyTransfer:Zone:CORE_MID | 185.75 | 0.00 | 01-JAN-00:10 | 19201.95 | 05-SEP-07:40 |
EnergyTransfer:Zone:CORE_TOP | 188.16 | 0.00 | 01-JAN-00:10 | 20778.34 | 19-JUN-13:50 |
Heating:EnergyTransfer:Zone:CORE_TOP | 0.10 | 0.00 | 01-JAN-00:10 | 9581.11 | 02-JAN-07:10 |
General:Heating:EnergyTransfer:Zone:CORE_TOP | 0.10 | 0.00 | 01-JAN-00:10 | 9581.11 | 02-JAN-07:10 |
Cooling:EnergyTransfer:Zone:CORE_TOP | 188.06 | 0.00 | 01-JAN-00:10 | 20778.34 | 19-JUN-13:50 |
General:Cooling:EnergyTransfer:Zone:CORE_TOP | 188.06 | 0.00 | 01-JAN-00:10 | 20778.34 | 19-JUN-13:50 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 52.37 | 0.00 | 01-JAN-00:10 | 7987.39 | 28-JUN-16:00 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 0.73 | 0.00 | 01-JAN-00:10 | 5866.67 | 02-JAN-06:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 0.73 | 0.00 | 01-JAN-00:10 | 5866.67 | 02-JAN-06:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 51.64 | 0.00 | 01-JAN-00:10 | 7987.39 | 28-JUN-16:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 51.64 | 0.00 | 01-JAN-00:10 | 7987.39 | 28-JUN-16:00 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 50.80 | 0.00 | 01-JAN-00:10 | 8581.97 | 19-JUN-09:20 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 0.31 | 0.00 | 01-JAN-00:10 | 3709.68 | 02-JAN-06:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 0.31 | 0.00 | 01-JAN-00:10 | 3709.68 | 02-JAN-06:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 50.49 | 0.00 | 01-JAN-00:10 | 8581.97 | 19-JUN-09:20 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 50.49 | 0.00 | 01-JAN-00:10 | 8581.97 | 19-JUN-09:20 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 76.94 | 0.00 | 01-JAN-00:10 | 11989.12 | 02-OCT-13:00 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 0.37 | 0.00 | 01-JAN-00:10 | 5133.46 | 07-DEC-06:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 0.37 | 0.00 | 01-JAN-00:10 | 5133.46 | 07-DEC-06:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 76.57 | 0.00 | 01-JAN-00:10 | 11989.12 | 02-OCT-13:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 76.57 | 0.00 | 01-JAN-00:10 | 11989.12 | 02-OCT-13:00 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 50.00 | 0.00 | 01-JAN-00:10 | 9248.23 | 26-JUN-16:00 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 0.45 | 0.00 | 01-JAN-00:10 | 3670.50 | 18-DEC-06:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 0.45 | 0.00 | 01-JAN-00:10 | 3670.50 | 18-DEC-06:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 49.55 | 0.00 | 01-JAN-00:10 | 9248.23 | 26-JUN-16:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 49.55 | 0.00 | 01-JAN-00:10 | 9248.23 | 26-JUN-16:00 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 48.97 | 0.00 | 01-JAN-00:10 | 6820.19 | 17-JUL-14:30 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 0.03 | 0.00 | 01-JAN-00:10 | 2294.06 | 02-JAN-07:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 0.03 | 0.00 | 01-JAN-00:10 | 2294.06 | 02-JAN-07:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 48.93 | 0.00 | 01-JAN-00:10 | 6820.19 | 17-JUL-14:30 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 48.93 | 0.00 | 01-JAN-00:10 | 6820.19 | 17-JUL-14:30 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 48.52 | 0.00 | 01-JAN-00:10 | 7575.66 | 14-AUG-09:30 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 0.01 | 0.00 | 01-JAN-00:10 | 1234.40 | 02-JAN-07:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 0.01 | 0.00 | 01-JAN-00:10 | 1234.40 | 02-JAN-07:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 48.52 | 0.00 | 01-JAN-00:10 | 7575.66 | 14-AUG-09:30 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 48.52 | 0.00 | 01-JAN-00:10 | 7575.66 | 14-AUG-09:30 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 82.37 | 0.00 | 01-JAN-00:10 | 13481.33 | 28-JUN-17:00 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 2.65 | 0.00 | 01-JAN-00:10 | 7579.61 | 06-DEC-07:40 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 2.65 | 0.00 | 01-JAN-00:10 | 7579.61 | 06-DEC-07:40 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 79.72 | 0.00 | 01-JAN-00:10 | 13481.33 | 28-JUN-17:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 79.72 | 0.00 | 01-JAN-00:10 | 13481.33 | 28-JUN-17:00 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 46.12 | 0.00 | 01-JAN-00:10 | 7516.93 | 07-SEP-16:00 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 0.01 | 0.00 | 01-JAN-00:10 | 1051.82 | 02-JAN-07:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 0.01 | 0.00 | 01-JAN-00:10 | 1051.82 | 02-JAN-07:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 46.11 | 0.00 | 01-JAN-00:10 | 7516.93 | 07-SEP-16:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 46.11 | 0.00 | 01-JAN-00:10 | 7516.93 | 07-SEP-16:00 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 49.92 | 0.00 | 01-JAN-00:10 | 7004.36 | 28-JUN-16:00 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 0.07 | 0.00 | 01-JAN-00:10 | 2698.85 | 02-JAN-07:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 0.07 | 0.00 | 01-JAN-00:10 | 2698.85 | 02-JAN-07:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 49.85 | 0.00 | 01-JAN-00:10 | 7004.36 | 28-JUN-16:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 49.85 | 0.00 | 01-JAN-00:10 | 7004.36 | 28-JUN-16:00 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 48.38 | 0.00 | 01-JAN-00:10 | 8180.02 | 19-JUN-09:00 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 0.04 | 0.00 | 01-JAN-00:10 | 1660.78 | 02-JAN-07:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 0.04 | 0.00 | 01-JAN-00:10 | 1660.78 | 02-JAN-07:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 48.35 | 0.00 | 01-JAN-00:10 | 8180.02 | 19-JUN-09:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 48.35 | 0.00 | 01-JAN-00:10 | 8180.02 | 19-JUN-09:00 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 74.16 | 0.00 | 01-JAN-00:10 | 10548.76 | 02-OCT-13:10 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 0.02 | 0.00 | 01-JAN-00:10 | 2302.39 | 07-DEC-07:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 0.02 | 0.00 | 01-JAN-00:10 | 2302.39 | 07-DEC-07:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 74.13 | 0.00 | 01-JAN-00:10 | 10548.76 | 02-OCT-13:10 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 74.13 | 0.00 | 01-JAN-00:10 | 10548.76 | 02-OCT-13:10 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 47.36 | 0.00 | 01-JAN-00:10 | 8463.06 | 26-JUN-16:00 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 0.05 | 0.00 | 01-JAN-00:10 | 1587.73 | 07-DEC-07:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 0.05 | 0.00 | 01-JAN-00:10 | 1587.73 | 07-DEC-07:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 47.31 | 0.00 | 01-JAN-00:10 | 8463.06 | 26-JUN-16:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 47.31 | 0.00 | 01-JAN-00:10 | 8463.06 | 26-JUN-16:00 |
PlantLoopHeatingDemand:Facility | 38.47 | 0.00 | 01-JAN-00:10 | 5187.66 | 20-JAN-12:10 |
PlantLoopHeatingDemand:Plant | 38.47 | 0.00 | 01-JAN-00:10 | 5187.66 | 20-JAN-12:10 |
WaterSystems:PlantLoopHeatingDemand | 38.47 | 0.00 | 01-JAN-00:10 | 5187.66 | 20-JAN-12:10 |
General:WaterSystems:PlantLoopHeatingDemand | 38.47 | 0.00 | 01-JAN-00:10 | 5187.66 | 20-JAN-12:10 |
EnergyTransfer:HVAC | 1502.03 | 0.00 | 01-JAN-00:10 | 276527.27 | 05-SEP-07:20 |
HeatingCoils:EnergyTransfer | 11.67 | 0.00 | 01-JAN-00:10 | 80744.21 | 06-DEC-07:10 |
CoolingCoils:EnergyTransfer | 1490.36 | 0.00 | 01-JAN-00:10 | 276527.27 | 05-SEP-07:20 |
EnergyTransfer:Plant | 38.47 | 0.00 | 01-JAN-00:10 | 5187.66 | 20-JAN-12:10 |
WaterSystems:EnergyTransfer | 38.47 | 0.00 | 01-JAN-00:10 | 5187.66 | 20-JAN-12:10 |
WaterUse:WaterSystems:EnergyTransfer | 38.47 | 0.00 | 01-JAN-00:10 | 5187.66 | 20-JAN-12:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
CORE_BOTTOM | 0.000 | 0.000 | 0.000 | -276.344 | 0.000 | 0.000 | 32.694 | 48.333 | 236.167 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -40.851 |
CORE_MID | 0.000 | 0.000 | 0.000 | -185.752 | 0.000 | 0.000 | 32.972 | 48.333 | 115.425 | 0.000 | 0.000 | 0.000 | 0.002 | 0.000 | 0.000 | 0.000 | 0.000 | -10.978 |
CORE_TOP | 0.000 | 0.000 | 0.096 | -188.064 | 0.000 | 0.000 | 33.475 | 48.333 | 115.425 | 0.000 | 0.000 | 0.000 | 0.001 | 0.000 | 0.000 | 0.000 | 0.000 | -9.266 |
PERIMETER_TOP_ZN_3 | 0.000 | 0.000 | 0.729 | -51.644 | 0.000 | 0.000 | 7.187 | 6.019 | 24.333 | 23.131 | 0.000 | 0.247 | 8.395 | 0.000 | -17.847 | 0.000 | -0.549 | -0.000 |
PERIMETER_TOP_ZN_2 | 0.000 | 0.000 | 0.313 | -50.492 | 0.000 | 0.000 | 4.465 | 3.726 | 15.404 | 39.879 | 0.000 | 0.162 | 0.000 | 0.000 | -11.246 | 0.000 | -0.381 | -1.830 |
PERIMETER_TOP_ZN_1 | 0.000 | 0.000 | 0.374 | -76.567 | 0.000 | 0.000 | 7.019 | 5.831 | 24.332 | 65.491 | 0.000 | 0.241 | 0.002 | 0.000 | -17.827 | 0.000 | -0.602 | -8.292 |
PERIMETER_TOP_ZN_4 | 0.000 | 0.000 | 0.447 | -49.552 | 0.000 | 0.000 | 4.566 | 3.776 | 15.403 | 38.382 | 0.000 | 0.161 | 0.000 | 0.000 | -12.235 | 0.000 | -0.381 | -0.567 |
PERIMETER_BOT_ZN_3 | 0.000 | 0.000 | 0.034 | -48.935 | 0.000 | 0.000 | 7.107 | 5.990 | 24.333 | 23.199 | 0.000 | 0.138 | 7.455 | 0.000 | -19.005 | 0.000 | -0.315 | 0.000 |
PERIMETER_BOT_ZN_2 | 0.000 | 0.000 | 0.006 | -48.517 | 0.000 | 0.000 | 4.412 | 3.716 | 15.404 | 39.876 | 0.000 | 0.087 | 0.002 | 0.000 | -12.276 | 0.000 | -0.225 | -2.483 |
PERIMETER_BOT_ZN_1 | 0.000 | 0.000 | 2.650 | -79.721 | 0.000 | 0.000 | 6.976 | 5.817 | 24.332 | 65.583 | 0.000 | 14.394 | 0.002 | 0.000 | -19.446 | 0.000 | -14.838 | -5.747 |
PERIMETER_BOT_ZN_4 | 0.000 | 0.000 | 0.008 | -46.114 | 0.000 | 0.000 | 4.471 | 3.764 | 15.403 | 38.401 | 0.000 | 0.086 | 0.000 | 0.000 | -13.380 | 0.000 | -0.225 | -2.413 |
PERIMETER_MID_ZN_3 | 0.000 | 0.000 | 0.071 | -49.846 | 0.000 | 0.000 | 7.087 | 6.019 | 24.333 | 23.021 | 0.000 | 0.209 | 8.719 | 0.000 | -19.115 | 0.000 | -0.497 | 0.000 |
PERIMETER_MID_ZN_2 | 0.000 | 0.000 | 0.035 | -48.348 | 0.000 | 0.000 | 3.275 | 3.726 | 15.404 | 39.803 | 0.000 | 0.137 | 0.002 | 0.000 | -11.938 | 0.000 | -0.341 | -1.751 |
PERIMETER_MID_ZN_1 | 0.000 | 0.000 | 0.023 | -74.132 | 0.000 | 0.000 | 6.950 | 5.831 | 24.332 | 65.401 | 0.000 | 0.203 | 0.005 | 0.000 | -18.928 | 0.000 | -0.539 | -9.142 |
PERIMETER_MID_ZN_4 | 0.000 | 0.000 | 0.046 | -47.311 | 0.000 | 0.000 | 4.499 | 3.776 | 15.403 | 38.332 | 0.000 | 0.134 | 0.002 | 0.000 | -13.056 | 0.000 | -0.343 | -1.480 |
TOPFLOOR_PLENUM | 5.508 | -62.060 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.320 | 57.059 | 0.000 | 0.000 | 0.000 | -0.827 | -0.001 |
MIDFLOOR_PLENUM | 1.690 | -31.933 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.325 | 30.794 | 0.000 | 0.000 | 0.000 | -0.876 | -0.000 |
FIRSTFLOOR_PLENUM | 0.659 | -37.955 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.252 | 37.757 | 0.000 | 0.000 | 0.000 | -0.713 | -0.000 |
Total Facility | 7.858 | -131.948 | 4.832 | -1321.338 | 0.000 | 0.000 | 167.156 | 202.989 | 705.434 | 500.498 | 0.000 | 17.093 | 150.196 | 0.000 | -186.300 | 0.000 | -21.654 | -94.800 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
CORE_BOTTOM | 10-OCT-04:03 | 0.00 | 0.00 | 0.00 | -41456.34 | 0.00 | 0.00 | 0.00 | 468.92 | 4405.64 | 0.00 | 0.00 | 0.00 | 36581.78 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 11-SEP-04:02 | 0.00 | 0.00 | 0.00 | -31047.97 | 0.00 | 0.00 | 0.00 | 468.92 | 2442.06 | 0.00 | 0.00 | 0.00 | 28136.99 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 11-SEP-04:02 | 0.00 | 0.00 | 0.00 | -34593.80 | 0.00 | 0.00 | 0.00 | 468.92 | 2442.06 | 0.00 | 0.00 | 0.00 | 31682.83 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 16-JUL-15:12 | 0.00 | 0.00 | 0.00 | -13009.57 | 0.00 | 0.00 | 26.26 | 23.57 | 478.42 | 3036.79 | 0.00 | 60.83 | 9383.70 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 18-JUN-09:42 | 0.00 | 0.00 | 0.00 | -12198.34 | 0.00 | 0.00 | 12.91 | 14.92 | 302.86 | 6468.61 | 0.00 | 23.69 | 5375.36 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 09-OCT-13:52 | 0.00 | 0.00 | 0.00 | -15970.96 | 0.00 | 0.00 | 22.39 | 23.57 | 478.41 | 9496.06 | 0.00 | 6.96 | 5943.56 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 25-JUN-17:01 | 0.00 | 0.00 | 0.00 | -14095.41 | 0.00 | 0.00 | 0.00 | 14.92 | 244.42 | 8910.37 | 0.00 | 58.65 | 4867.04 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 04-JUL-19:02 | 0.00 | 0.00 | 0.00 | -10465.87 | 0.00 | 0.00 | 0.00 | 32.10 | 386.10 | 2113.82 | 0.00 | 50.37 | 7883.47 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 04-JUL-09:42 | 0.00 | 0.00 | 0.00 | -10829.40 | 0.00 | 0.00 | 15.32 | 14.92 | 302.86 | 6441.09 | 0.00 | 5.52 | 4049.69 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 28-JUN-17:00 | 0.00 | 0.00 | 0.00 | -13477.56 | 0.00 | 0.00 | 152.92 | 235.76 | 797.35 | 2931.49 | 0.00 | 14264.41 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -4904.37 |
PERIMETER_BOT_ZN_4 | 27-AUG-17:41 | 0.00 | 0.00 | 0.00 | -11769.44 | 0.00 | 0.00 | 0.00 | 14.92 | 244.42 | 5954.92 | 0.00 | 35.40 | 5519.77 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 25-JUN-18:11 | 0.00 | 0.00 | 0.00 | -10715.40 | 0.00 | 0.00 | 0.00 | 23.57 | 386.10 | 4053.67 | 0.00 | 118.37 | 6133.68 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 04-JUL-09:42 | 0.00 | 0.00 | 0.00 | -11869.66 | 0.00 | 0.00 | 14.40 | 14.92 | 302.86 | 6389.23 | 0.00 | 7.84 | 5140.40 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 25-DEC-13:52 | 0.00 | 0.00 | 0.00 | -13337.61 | 0.00 | 0.00 | 23.84 | 23.57 | 478.41 | 11932.48 | 0.00 | 0.00 | 888.66 | 0.00 | -0.00 | 0.00 | -9.36 | 0.00 |
PERIMETER_MID_ZN_4 | 30-APR-17:31 | 0.00 | 0.00 | 0.00 | -12638.31 | 0.00 | 0.00 | 0.00 | 14.92 | 244.42 | 6203.61 | 0.00 | 19.72 | 6155.64 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 28-JUN-14:40 | 0.00 | -12922.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 71.40 | 12851.38 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 19-JUN-12:03 | 0.00 | -5670.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 57.17 | 5613.65 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 19-JUN-12:08 | 0.00 | -7474.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43.77 | 7430.53 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 10-JUL-04:02 | 0.00 | 9212.90 | 0.00 | -204380.71 | 0.00 | 0.00 | 0.00 | 2375.34 | 14333.92 | 0.00 | 0.00 | 88.12 | 181404.69 | 0.00 | -3034.26 | 0.00 | 0.00 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
CORE_BOTTOM | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 02-JAN-06:01 | 0.00 | 0.00 | 23858.27 | 0.00 | 0.00 | 0.00 | 466.51 | 468.92 | 3025.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -27819.62 |
PERIMETER_TOP_ZN_3 | 02-JAN-06:01 | 0.00 | 0.00 | 10188.75 | 0.00 | 0.00 | 0.00 | 107.70 | 98.85 | 637.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1862.80 | 0.00 | -12.05 | -9158.34 |
PERIMETER_TOP_ZN_2 | 02-JAN-06:01 | 0.00 | 0.00 | 7369.77 | 0.00 | 0.00 | 0.00 | 67.98 | 62.58 | 403.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1266.47 | 0.00 | -8.13 | -6629.54 |
PERIMETER_TOP_ZN_1 | 07-DEC-06:01 | 0.00 | 0.00 | 10884.13 | 0.00 | 0.00 | 0.00 | 105.49 | 98.85 | 637.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2640.98 | 0.00 | -32.69 | -9052.68 |
PERIMETER_TOP_ZN_4 | 02-JAN-06:01 | 0.00 | 0.00 | 7121.87 | 0.00 | 0.00 | 0.00 | 67.45 | 62.58 | 403.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1270.50 | 0.00 | -8.25 | -6376.95 |
PERIMETER_BOT_ZN_3 | 02-JAN-06:01 | 0.00 | 0.00 | 6289.35 | 0.00 | 0.00 | 0.00 | 98.89 | 98.85 | 637.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2130.40 | 0.00 | -7.36 | -4987.22 |
PERIMETER_BOT_ZN_2 | 18-DEC-07:01 | 0.00 | 0.00 | 3918.14 | 0.00 | 0.00 | 0.00 | 120.25 | 187.74 | 403.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1631.17 | 0.00 | -9.92 | -2988.85 |
PERIMETER_BOT_ZN_1 | 06-DEC-07:10 | 0.00 | 0.00 | 7955.88 | 0.00 | 0.00 | 0.00 | 193.30 | 296.56 | 637.88 | 0.00 | 0.00 | 0.00 | 13615.12 | 0.00 | -2938.45 | 0.00 | -19760.29 | 0.00 |
PERIMETER_BOT_ZN_4 | 08-FEB-07:02 | 0.00 | 0.00 | 3944.68 | 0.00 | 0.00 | 0.00 | 120.62 | 187.73 | 403.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1257.99 | 0.00 | -3.11 | -3395.74 |
PERIMETER_MID_ZN_3 | 02-JAN-06:01 | 0.00 | 0.00 | 7826.53 | 0.00 | 0.00 | 0.00 | 100.16 | 98.85 | 637.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2100.95 | 0.00 | -11.38 | -6551.09 |
PERIMETER_MID_ZN_2 | 07-DEC-06:01 | 0.00 | 0.00 | 4923.74 | 0.00 | 0.00 | 0.00 | 62.69 | 62.58 | 403.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1905.19 | 0.00 | -19.48 | -3528.15 |
PERIMETER_MID_ZN_1 | 06-DEC-07:01 | 0.00 | 0.00 | 7374.72 | 0.00 | 0.00 | 0.00 | 193.30 | 296.56 | 637.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2852.90 | 0.00 | -9.81 | -5639.74 |
PERIMETER_MID_ZN_4 | 02-JAN-06:01 | 0.00 | 0.00 | 4918.66 | 0.00 | 0.00 | 0.00 | 62.58 | 62.58 | 403.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1429.70 | 0.00 | -7.74 | -4010.18 |
TOPFLOOR_PLENUM | 07-DEC-07:02 | 9050.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -41.72 | -9008.68 |
MIDFLOOR_PLENUM | 25-DEC-16:33 | 4400.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.79 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -4404.70 |
FIRSTFLOOR_PLENUM | 24-NOV-06:02 | 5721.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -25.52 | -5695.71 |
Total Facility | 07-DEC-07:01 | -6878.97 | 12120.32 | 97726.43 | -12120.32 | 0.00 | 0.00 | 4401.90 | 7126.03 | 21098.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -26104.29 | 0.00 | -22326.04 | -75043.87 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PACU_VAV_BOT | 5.7967 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 5.3112 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
PACU_VAV_MID | 5.1400 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 4.5789 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
PACU_VAV_TOP | 5.7572 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 5.4990 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PACU_VAV_BOT | 2.8983 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 1.3973 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
PACU_VAV_MID | 2.5700 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 1.3723 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
PACU_VAV_TOP | 2.8786 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 1.4721 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
CORE_BOTTOM | PACU_VAV_BOT | 0.000000 | 52.9387 | 0.000432 | 983.54 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
CORE_MID | PACU_VAV_MID | 0.000000 | 52.9387 | 0.000432 | 983.54 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
CORE_TOP | PACU_VAV_TOP | 0.000000 | 52.9387 | 0.000432 | 983.54 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP | 0.000000 | 7.0652 | 0.000432 | 131.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP | 0.000000 | 7.0647 | 0.000432 | 131.25 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT | 0.000000 | 7.0652 | 0.000432 | 131.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT | 0.000000 | 7.0647 | 0.000432 | 131.25 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_3 | PACU_VAV_MID | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_2 | PACU_VAV_MID | 0.000000 | 7.0652 | 0.000432 | 131.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_1 | PACU_VAV_MID | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_4 | PACU_VAV_MID | 0.000000 | 7.0647 | 0.000432 | 131.25 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PACU_VAV_BOT | 0.00 | 0.000432 | 1660.7286 | 0.0000 | 0.0000 | 0.0000 | |
PACU_VAV_MID | 0.00 | 0.000432 | 1660.7286 | 0.0000 | 0.0000 | 0.0000 | |
PACU_VAV_TOP | 0.00 | 0.000432 | 1660.7286 | 0.0000 | 0.0000 | 0.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
CORE_BOTTOM | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 3.0108 | 3.0108 | 0.7949 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_MID | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.2025 | 2.2025 | 0.7621 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_TOP | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.4223 | 2.4223 | 0.8018 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.8283 | 0.8283 | 0.1690 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7429 | 0.7429 | 0.1486 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.9207 | 0.9207 | 0.1841 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.8431 | 0.8431 | 0.1686 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.6843 | 0.6843 | 0.1677 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.6511 | 0.6511 | 0.1302 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7647 | 0.7647 | 0.1675 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.6857 | 0.6857 | 0.1371 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_3 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7014 | 0.7014 | 0.1606 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_2 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.6993 | 0.6993 | 0.1399 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_1 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7911 | 0.7911 | 0.1606 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_4 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7457 | 0.7457 | 0.1491 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PACU_VAV_BOT | 5.7967 | 5.3112 | 5.7967 | 1.3973 | 0.0000 | 1.0000 |
PACU_VAV_MID | 5.1400 | 4.5789 | 5.1400 | 1.3723 | 0.0000 | 1.0000 |
PACU_VAV_TOP | 5.7572 | 5.4990 | 5.7572 | 1.4721 | 0.0000 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
CORE_BOTTOM | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.5054 | 1.5054 | 0.7949 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_MID | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.1013 | 1.1013 | 0.7621 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_TOP | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.2111 | 1.2111 | 0.8018 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4142 | 0.4142 | 0.1690 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3714 | 0.3714 | 0.1486 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4603 | 0.4603 | 0.1841 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4215 | 0.4215 | 0.1686 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3422 | 0.3422 | 0.1677 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3255 | 0.3255 | 0.1302 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3824 | 0.3824 | 0.1675 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3429 | 0.3429 | 0.1371 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_3 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3507 | 0.3507 | 0.1606 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_2 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3497 | 0.3497 | 0.1399 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_1 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3955 | 0.3955 | 0.1606 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_4 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3728 | 0.3728 | 0.1491 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PACU_VAV_BOT | 2.8983 | 1.3973 | 1.3973 | 1.3973 | 0.0000 | 1.0000 |
PACU_VAV_MID | 2.5700 | 1.3723 | 1.3723 | 1.3723 | 0.0000 | 1.0000 |
PACU_VAV_TOP | 2.8786 | 1.4721 | 1.4721 | 1.4721 | 0.0000 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** Tucson-Davis Monthan AFB AZ USA TMY3 WMO#=722745 |
Total gross floor area [m2] | 4982.19 |
Principal Heating Source | Electricity |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
CORE_BOTTOM | 983.54 | 983.54 | 0.00 | 113.98 |
CORE_MID | 983.54 | 983.54 | 0.00 | 113.98 |
CORE_TOP | 983.54 | 983.54 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_3 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_2 | 131.26 | 131.26 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_1 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_4 | 131.25 | 131.25 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_3 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_2 | 131.26 | 131.26 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_1 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_4 | 131.25 | 131.25 | 0.00 | 113.98 |
PERIMETER_MID_ZN_3 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_MID_ZN_2 | 131.26 | 131.26 | 0.00 | 96.54 |
PERIMETER_MID_ZN_1 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_MID_ZN_4 | 131.25 | 131.25 | 0.00 | 113.98 |
TOPFLOOR_PLENUM | 1660.73 | 1660.73 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 1660.73 | 1660.73 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 1660.73 | 1660.73 | 0.00 | 0.00 |
Totals | 4982.19 | 4982.19 | 0.00 |
Data | |
Number of hours heating loads not met | 80.00 |
Number of hours cooling loads not met | 504.67 |
Number of hours not met | 584.67 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- General | 9.10 | 63809.45 | 3.20 | 31102.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- General | 426.67 | 89640.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 202.99 | 21377.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 49.88 | 5557.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 584.69 | 34487.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- ElevatorLift | 120.10 | 11290.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- ElevatorLightsFan | 0.64 | 86.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Transformer | 11.66 | 833.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 138.67 | 26643.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- General | 0.02 | 0.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 0.00 | 0.00 | 94.21 | 9062.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 705.43 | 1544.41 |
Natural Gas | 0.00 | 97.41 |
Additional | 0.00 | 0.00 |
Total | 705.43 | 1641.82 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 40.74 |
Space Heating | 1.83 |
Space Cooling | 85.64 |
Fans (All) | 27.83 |
Service Water Heating | 0.00 |
Receptacle Equipment | 141.59 |
Miscellaneous (All) | 309.99 |
Subtotal | 309.99 |
Natural Gas [MJ/m2] | |
Space Heating | 0.64 |
Service Water Heating | 18.91 |
Miscellaneous (All) | 19.55 |
Subtotal | 19.55 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 12.36 |
Space Heating | 0.75 |
Space Cooling | 25.99 |
Fans (All) | 8.45 |
Service Water Heating | 5.74 |
Receptacle Equipment | 42.97 |
Miscellaneous | 3.75 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 4472. | 4472. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_C_2016 | 6752. | 8760. |
ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 6828. | 8760. |
ALWAYS_OFF | 0. | 0. |
LTG_SCH_OFFICE | 2362. | 8760. |
BLDG_EQUIP_SCH | 4095. | 8760. |
BLDG_OCC_SCH | 2528. | 5992. |
BLDG_OCC_SCH_W_SB | 1878. | 5056. |
BLDG_OCC_SCH_WO_SB | 2545. | 5992. |
BLDG_ELEVATORS | 2070. | 8760. |
ELEV_LIGHT_FAN_SCH_24_7 | 8760. | 8760. |
ELEV_LIGHT_FAN_SCH_ADD_DF | 1470. | 4212. |
BLDG_SWH_SCH | 1441. | 5992. |
WORK_EFF_SCH | 0. | 0. |
FAN_SCH | 8760. | 8760. |
REHEATCOILAVAILSCHED | 8760. | 8760. |
COOLINGCOILAVAILSCHED | 8760. | 8760. |
MINOA_MOTORIZEDDAMPER_SCHED | 4472. | 4472. |
MINOA_SCHED | 8760. | 8760. |
CORE_BOTTOM SUB CAT LATENT FRACT SCHED | 438. | 8760. |
CORE_BOTTOM SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
CORE_MID SUB CAT LATENT FRACT SCHED | 438. | 8760. |
CORE_MID SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
CORE_TOP SUB CAT LATENT FRACT SCHED | 438. | 8760. |
CORE_TOP SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_TOP_ZN_3 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_TOP_ZN_3 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_TOP_ZN_2 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_TOP_ZN_2 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_TOP_ZN_1 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_TOP_ZN_1 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_TOP_ZN_4 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_TOP_ZN_4 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_BOT_ZN_3 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_BOT_ZN_3 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_BOT_ZN_2 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_BOT_ZN_2 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_BOT_ZN_1 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_BOT_ZN_1 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_BOT_ZN_4 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_BOT_ZN_4 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_MID_ZN_3 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_MID_ZN_3 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_MID_ZN_2 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_MID_ZN_2 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_MID_ZN_1 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_MID_ZN_1 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_MID_ZN_4 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_MID_ZN_4 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
INFIL_SCH_PNNL | 5172. | 8760. |
INFIL_DOOR_OPENING_SCH | 1154. | 3380. |
PERIMETER_MID_ZN_2_OA_MULT | 7824. | 7824. |
PERIMETER_MID_ZN_2_MDP_SCH | 1574. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
HTGSETP_SCH_YES_OPTIMUM_STARTSTOP | CORE_BOTTOM DUAL SP CONTROL | January | 21.00 | 365 | 15.60 | 365 |
CLGSETP_SCH_YES_OPTIMUM_STARTSTOP | CORE_BOTTOM DUAL SP CONTROL | July | 24.00 | 365 | 26.70 | 365 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
Heat Index HoursSafe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
CORE_BOTTOM | 8690.00 | 70.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 8745.67 | 14.33 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 8752.00 | 8.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 8699.00 | 61.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 8648.17 | 111.83 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 8668.50 | 91.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 8611.83 | 148.17 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 8748.00 | 12.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 8636.00 | 124.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 8620.50 | 139.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 8608.00 | 152.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 8723.50 | 36.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 8679.67 | 80.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 8682.83 | 77.17 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 8634.67 | 125.33 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 8514.50 | 245.50 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 8756.00 | 4.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 8756.83 | 3.17 | 0.00 | 0.00 | 0.00 |
Min | 8514.50 | 3.17 | 0.00 | 0.00 | 0.00 |
Max | 8756.83 | 245.50 | 0.00 | 0.00 | 0.00 |
Average | 8676.43 | 83.57 | 0.00 | 0.00 | 0.00 |
Sum | 156175.67 | 1504.33 | 0.00 | 0.00 | 0.00 |
Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
CORE_BOTTOM | 128284.00 | 20.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 128300.00 | 4.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 128304.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 24805.00 | 104.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 10134.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 128304.00 | 104.00 | 0.00 | 0.00 | 0.00 |
Average | 34136.22 | 7.11 | 0.00 | 0.00 | 0.00 |
Sum | 614452.00 | 128.00 | 0.00 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
CORE_BOTTOM | 8469.67 | 290.33 | 0.00 | 0.00 | 0.00 |
CORE_MID | 8543.17 | 216.83 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 8607.33 | 152.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 8519.17 | 240.83 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 8496.00 | 264.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 8502.00 | 258.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 8498.83 | 261.17 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 8498.67 | 261.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 8429.33 | 330.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 8396.67 | 363.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 8429.00 | 331.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 8463.50 | 296.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 8428.83 | 331.17 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 8420.33 | 339.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 8419.17 | 340.83 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 8097.17 | 662.83 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 8550.50 | 209.50 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 8562.83 | 197.17 | 0.00 | 0.00 | 0.00 |
Min | 8097.17 | 152.67 | 0.00 | 0.00 | 0.00 |
Max | 8607.33 | 662.83 | 0.00 | 0.00 | 0.00 |
Average | 8462.90 | 297.10 | 0.00 | 0.00 | 0.00 |
Sum | 152332.17 | 5347.83 | 0.00 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
CORE_BOTTOM | 128152.33 | 151.67 | 0.00 | 0.00 | 0.00 |
CORE_MID | 128212.67 | 91.33 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 128216.50 | 87.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 24908.50 | 0.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 24908.50 | 0.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 24908.67 | 0.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 24705.17 | 203.83 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 24881.17 | 27.83 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 10134.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 24892.83 | 16.17 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 128216.50 | 203.83 | 0.00 | 0.00 | 0.00 |
Average | 34111.13 | 32.20 | 0.00 | 0.00 | 0.00 |
Sum | 614000.33 | 579.67 | 0.00 | 0.00 | 0.00 |
SET ≤ 12.2°C Hours (°C) | SET ≤ 12.2°C OccupantHours (°C) | Longest SET ≤ 12.2°C Duration [hr] | Start Time of the Longest SET ≤ 12.2°C Duration | |
None |
SET > 30°C Hours (°C) | SET > 30°C OccupantHours (°C) | Longest SET > 30°C Duration [hr] | Start Time of the Longest SET > 30°C Duration | |
None |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
CO2 Level HoursSafe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 08:35:20
Illuminance Level HoursA Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
CORE_BOTTOM | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_3 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_2 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_1 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_4 | 0.00 | 0.00 | 8760.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 0.00 | 0.00 | 8760.00 | 0.00 |
Average | 0.00 | 0.00 | 5840.00 | 0.00 |
Sum | 0.00 | 0.00 | 105120.00 | 0.00 |
A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
CORE_BOTTOM | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 0.00 | 0.00 | 14016.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 0.00 | 0.00 | 14016.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 0.00 | 0.00 | 14016.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 0.00 | 0.00 | 14016.00 | 0.00 |
PERIMETER_MID_ZN_3 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_MID_ZN_2 | 0.00 | 0.00 | 10134.00 | 0.00 |
PERIMETER_MID_ZN_1 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_MID_ZN_4 | 0.00 | 0.00 | 14016.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 0.00 | 0.00 | 24909.00 | 0.00 |
Average | 0.00 | 0.00 | 12759.33 | 0.00 |
Sum | 0.00 | 0.00 | 229668.00 | 0.00 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Environment
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 14.827 |
February | 12.716 |
March | 15.425 |
April | 23.310 |
May | 26.312 |
June | 31.196 |
July | 30.423 |
August | 29.815 |
September | 27.754 |
October | 20.869 |
November | 15.431 |
December | 11.863 |
Annual Sum or Average | 21.705 |
Minimum of Months | 11.863 |
Maximum of Months | 31.196 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Environment
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 14.827 |
February | 12.716 |
March | 15.425 |
April | 23.310 |
May | 26.312 |
June | 31.196 |
July | 30.423 |
August | 29.815 |
September | 27.754 |
October | 20.869 |
November | 15.431 |
December | 11.863 |
Annual Sum or Average | 21.705 |
Minimum of Months | 11.863 |
Maximum of Months | 31.196 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2021
For: Environment
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 14.827 |
February | 12.716 |
March | 15.425 |
April | 23.310 |
May | 26.312 |
June | 31.196 |
July | 30.423 |
August | 29.815 |
September | 27.754 |
October | 20.869 |
November | 15.431 |
December | 11.863 |
Annual Sum or Average | 21.705 |
Minimum of Months | 11.863 |
Maximum of Months | 31.196 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Environment
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 14.827 |
February | 12.716 |
March | 15.425 |
April | 23.310 |
May | 26.312 |
June | 31.196 |
July | 30.423 |
August | 29.815 |
September | 27.754 |
October | 20.869 |
November | 15.431 |
December | 11.863 |
Annual Sum or Average | 21.705 |
Minimum of Months | 11.863 |
Maximum of Months | 31.196 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME OFFICEMEDIUM
For: Environment
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 14.827 |
February | 12.716 |
March | 15.425 |
April | 23.310 |
May | 26.312 |
June | 31.196 |
July | 30.423 |
August | 29.815 |
September | 27.754 |
October | 20.869 |
November | 15.431 |
December | 11.863 |
Annual Sum or Average | 21.705 |
Minimum of Months | 11.863 |
Maximum of Months | 31.196 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Environment
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 14.827 |
February | 12.716 |
March | 15.425 |
April | 23.310 |
May | 26.312 |
June | 31.196 |
July | 30.423 |
August | 29.815 |
September | 27.754 |
October | 20.869 |
November | 15.431 |
December | 11.863 |
Annual Sum or Average | 21.705 |
Minimum of Months | 11.863 |
Maximum of Months | 31.196 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Environment
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 14.827 |
February | 12.716 |
March | 15.425 |
April | 23.310 |
May | 26.312 |
June | 31.196 |
July | 30.423 |
August | 29.815 |
September | 27.754 |
October | 20.869 |
November | 15.431 |
December | 11.863 |
Annual Sum or Average | 21.705 |
Minimum of Months | 11.863 |
Maximum of Months | 31.196 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 2B
For: Environment
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 14.827 |
February | 12.716 |
March | 15.425 |
April | 23.310 |
May | 26.312 |
June | 31.196 |
July | 30.423 |
August | 29.815 |
September | 27.754 |
October | 20.869 |
November | 15.431 |
December | 11.863 |
Annual Sum or Average | 21.705 |
Minimum of Months | 11.863 |
Maximum of Months | 31.196 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_AZ_TUCSON
For: Environment
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 14.827 |
February | 12.716 |
March | 15.425 |
April | 23.310 |
May | 26.312 |
June | 31.196 |
July | 30.423 |
August | 29.815 |
September | 27.754 |
October | 20.869 |
November | 15.431 |
December | 11.863 |
Annual Sum or Average | 21.705 |
Minimum of Months | 11.863 |
Maximum of Months | 31.196 |
Report: ZoneCoolingSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.187182E+11 | 33662.21 | 30-JAN-06:02 | 7.00 | 1.99 | 0.198829E+10 | 2606.69 | 23-JAN-14:09 | 7.00 | 1.99 |
February | 0.149036E+11 | 35875.96 | 01-FEB-06:02 | 5.00 | 3.59 | 0.180188E+10 | 2606.73 | 15-FEB-14:00 | 20.00 | 13.98 |
March | 0.197162E+11 | 35967.49 | 22-MAR-05:03 | 10.82 | 7.92 | 0.215725E+10 | 2606.69 | 17-MAR-09:00 | 10.82 | 7.92 |
April | 0.233045E+11 | 39790.42 | 29-APR-05:03 | 19.00 | 7.14 | 0.191629E+10 | 2606.67 | 03-APR-09:30 | 19.00 | 7.14 |
May | 0.262155E+11 | 38832.37 | 08-MAY-04:03 | 22.00 | 10.09 | 0.207625E+10 | 2606.66 | 22-MAY-09:00 | 25.00 | 9.85 |
June | 0.282311E+11 | 41447.64 | 20-JUN-04:03 | 22.50 | 10.06 | 0.207047E+10 | 2606.66 | 29-JUN-09:09 | 33.17 | 18.03 |
July | 0.276591E+11 | 41109.86 | 06-JUL-04:03 | 22.00 | 11.55 | 0.192501E+10 | 2606.71 | 28-JUL-13:50 | 29.50 | 20.43 |
August | 0.291790E+11 | 40759.11 | 22-AUG-04:03 | 23.83 | 15.27 | 0.216033E+10 | 2606.77 | 29-AUG-13:39 | 28.67 | 21.18 |
September | 0.265803E+11 | 41263.74 | 12-SEP-04:03 | 22.28 | 18.52 | 0.191947E+10 | 2606.66 | 15-SEP-09:09 | 25.45 | 16.44 |
October | 0.243609E+11 | 41449.44 | 10-OCT-04:03 | 18.00 | 12.10 | 0.199439E+10 | 2606.66 | 17-OCT-09:30 | 25.00 | 10.00 |
November | 0.205346E+11 | 39181.57 | 17-NOV-06:02 | 7.00 | 7.00 | 0.197332E+10 | 2606.76 | 16-NOV-14:09 | 7.00 | 7.00 |
December | 0.169409E+11 | 35114.71 | 27-DEC-06:02 | 6.00 | 2.08 | 0.191678E+10 | 2606.65 | 13-DEC-10:09 | 6.00 | 2.08 |
Annual Sum or Average | 0.276344E+12 | 0.238997E+11 | ||||||||
Minimum of Months | 0.149036E+11 | 33662.21 | 5.00 | 1.99 | 0.180188E+10 | 2606.65 | 6.00 | 1.99 | ||
Maximum of Months | 0.291790E+11 | 41449.44 | 23.83 | 18.52 | 0.216033E+10 | 2606.77 | 33.17 | 21.18 |
Report: ZoneCoolingSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.188473E+10 | 5597.80 | 31-JAN-16:20 | 29.00 | 10.73 | 0.00 | 0.00 | 01-JAN-00:10 | 29.00 | 10.73 |
February | 0.100699E+10 | 3976.71 | 23-FEB-14:40 | 18.00 | 10.49 | 0.00 | 0.00 | 01-FEB-00:10 | 18.00 | 10.49 |
March | 0.221376E+10 | 6799.91 | 20-MAR-14:50 | 27.70 | 14.23 | 0.00 | 0.00 | 01-MAR-00:10 | 27.70 | 14.23 |
April | 0.601652E+10 | 10868.70 | 14-APR-15:20 | 35.00 | 14.57 | 0.00 | 0.00 | 01-APR-00:10 | 35.00 | 14.57 |
May | 0.768096E+10 | 10696.53 | 15-MAY-15:10 | 36.00 | 15.08 | 0.00 | 0.00 | 01-MAY-00:10 | 36.00 | 15.08 |
June | 0.106104E+11 | 12922.27 | 28-JUN-14:40 | 41.67 | 19.29 | 0.00 | 0.00 | 01-JUN-00:10 | 41.67 | 19.29 |
July | 0.931323E+10 | 12221.86 | 10-JUL-14:30 | 38.50 | 18.55 | 0.00 | 0.00 | 01-JUL-00:10 | 38.50 | 18.55 |
August | 0.913177E+10 | 12223.60 | 25-AUG-15:20 | 41.00 | 17.61 | 0.00 | 0.00 | 01-AUG-00:10 | 41.00 | 17.61 |
September | 0.701119E+10 | 11266.29 | 07-SEP-15:00 | 37.20 | 19.77 | 0.00 | 0.00 | 01-SEP-00:10 | 37.20 | 19.77 |
October | 0.414164E+10 | 10206.31 | 02-OCT-14:20 | 35.00 | 19.60 | 0.00 | 0.00 | 01-OCT-00:10 | 35.00 | 19.60 |
November | 0.195845E+10 | 6759.90 | 01-NOV-15:40 | 28.33 | 15.88 | 0.00 | 0.00 | 01-NOV-00:10 | 28.33 | 15.88 |
December | 0.109139E+10 | 4225.08 | 22-DEC-16:20 | 24.67 | 9.90 | 0.00 | 0.00 | 01-DEC-00:10 | 24.67 | 9.90 |
Annual Sum or Average | 0.620610E+11 | 0.00 | ||||||||
Minimum of Months | 0.100699E+10 | 3976.71 | 18.00 | 9.90 | 0.00 | 0.00 | 18.00 | 9.90 | ||
Maximum of Months | 0.106104E+11 | 12922.27 | 41.67 | 19.77 | 0.00 | 0.00 | 41.67 | 19.77 |
Report: ZoneCoolingSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.630161E+09 | 1755.36 | 27-JAN-17:00 | 26.00 | 9.22 | 0.00 | 0.00 | 01-JAN-00:10 | 26.00 | 9.22 |
February | 0.379039E+09 | 1209.14 | 08-FEB-07:02 | 6.17 | 6.08 | 0.00 | 0.00 | 01-FEB-00:10 | 6.17 | 6.08 |
March | 0.836429E+09 | 2235.42 | 20-MAR-16:00 | 28.30 | 14.35 | 0.00 | 0.00 | 01-MAR-00:10 | 28.30 | 14.35 |
April | 0.284729E+10 | 4208.91 | 24-APR-15:50 | 33.83 | 13.43 | 0.00 | 0.00 | 01-APR-00:10 | 33.83 | 13.43 |
May | 0.392566E+10 | 4616.89 | 08-MAY-16:00 | 34.00 | 13.77 | 0.00 | 0.00 | 01-MAY-00:10 | 34.00 | 13.77 |
June | 0.549640E+10 | 5670.70 | 19-JUN-12:03 | 37.17 | 17.20 | 0.00 | 0.00 | 01-JUN-00:10 | 37.17 | 17.20 |
July | 0.511161E+10 | 5473.80 | 31-JUL-16:00 | 39.00 | 19.54 | 0.00 | 0.00 | 01-JUL-00:10 | 39.00 | 19.54 |
August | 0.506809E+10 | 5614.44 | 14-AUG-15:20 | 38.00 | 19.72 | 0.00 | 0.00 | 01-AUG-00:10 | 38.00 | 19.72 |
September | 0.414923E+10 | 5284.05 | 05-SEP-16:00 | 33.80 | 20.30 | 0.00 | 0.00 | 01-SEP-00:10 | 33.80 | 20.30 |
October | 0.230908E+10 | 5076.95 | 02-OCT-15:50 | 34.17 | 19.12 | 0.00 | 0.00 | 01-OCT-00:10 | 34.17 | 19.12 |
November | 0.864935E+09 | 2543.09 | 01-NOV-16:00 | 28.00 | 15.72 | 0.00 | 0.00 | 01-NOV-00:10 | 28.00 | 15.72 |
December | 0.315209E+09 | 2245.33 | 14-DEC-07:01 | 1.33 | -1.0 | 0.00 | 0.00 | 01-DEC-00:10 | 1.33 | -1.0 |
Annual Sum or Average | 0.319332E+11 | 0.00 | ||||||||
Minimum of Months | 0.315209E+09 | 1209.14 | 1.33 | -1.0 | 0.00 | 0.00 | 1.33 | -1.0 | ||
Maximum of Months | 0.549640E+10 | 5670.70 | 39.00 | 20.30 | 0.00 | 0.00 | 39.00 | 20.30 |
Report: ZoneCoolingSummaryMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.135706E+10 | 2548.79 | 27-JAN-17:00 | 26.00 | 9.22 | 0.00 | 0.00 | 01-JAN-00:10 | 26.00 | 9.22 |
February | 0.766482E+09 | 2405.85 | 01-FEB-07:07 | 5.00 | 3.59 | 0.00 | 0.00 | 01-FEB-00:10 | 5.00 | 3.59 |
March | 0.141994E+10 | 2842.71 | 20-MAR-16:00 | 28.30 | 14.35 | 0.00 | 0.00 | 01-MAR-00:10 | 28.30 | 14.35 |
April | 0.331198E+10 | 4596.90 | 24-APR-12:08 | 31.33 | 12.22 | 0.00 | 0.00 | 01-APR-00:10 | 31.33 | 12.22 |
May | 0.424424E+10 | 5193.97 | 08-MAY-12:08 | 32.17 | 13.12 | 0.00 | 0.00 | 01-MAY-00:10 | 32.17 | 13.12 |
June | 0.556962E+10 | 7474.02 | 19-JUN-12:08 | 37.17 | 17.20 | 0.00 | 0.00 | 01-JUN-00:10 | 37.17 | 17.20 |
July | 0.534564E+10 | 7131.57 | 10-JUL-12:08 | 37.00 | 19.54 | 0.00 | 0.00 | 01-JUL-00:10 | 37.00 | 19.54 |
August | 0.545080E+10 | 7163.26 | 14-AUG-12:10 | 36.33 | 20.21 | 0.00 | 0.00 | 01-AUG-00:10 | 36.33 | 20.21 |
September | 0.475062E+10 | 6265.29 | 06-SEP-17:09 | 35.72 | 20.47 | 0.00 | 0.00 | 01-SEP-00:10 | 35.72 | 20.47 |
October | 0.321111E+10 | 5158.27 | 02-OCT-07:10 | 25.17 | 17.22 | 0.00 | 0.00 | 01-OCT-00:10 | 25.17 | 17.22 |
November | 0.176727E+10 | 3328.43 | 02-NOV-16:00 | 26.00 | 15.13 | 0.00 | 0.00 | 01-NOV-00:10 | 26.00 | 15.13 |
December | 0.759689E+09 | 2505.43 | 06-DEC-07:01 | -0.5 | -5.0 | 0.00 | 0.00 | 01-DEC-00:10 | -0.5 | -5.0 |
Annual Sum or Average | 0.379545E+11 | 0.00 | ||||||||
Minimum of Months | 0.759689E+09 | 2405.85 | -0.5 | -5.0 | 0.00 | 0.00 | -0.5 | -5.0 | ||
Maximum of Months | 0.556962E+10 | 7474.02 | 37.17 | 20.47 | 0.00 | 0.00 | 37.17 | 20.47 |
Report: ZoneCoolingSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.111101E+11 | 12419.23 | 27-JAN-17:00 | 26.00 | 9.22 | 0.194239E+10 | 2606.64 | 09-JAN-10:09 | 26.00 | 9.22 |
February | 0.884790E+10 | 11353.50 | 01-FEB-17:00 | 15.00 | 6.61 | 0.174062E+10 | 2606.65 | 10-FEB-14:09 | 15.83 | 11.90 |
March | 0.119468E+11 | 15500.71 | 20-MAR-05:03 | 11.18 | 7.43 | 0.212476E+10 | 2606.66 | 14-MAR-13:50 | 11.18 | 7.43 |
April | 0.161721E+11 | 29936.71 | 26-APR-05:03 | 19.87 | 10.36 | 0.191049E+10 | 2606.65 | 03-APR-09:20 | 19.87 | 10.36 |
May | 0.187691E+11 | 30696.50 | 30-MAY-04:03 | 18.00 | 9.20 | 0.207339E+10 | 2606.64 | 30-MAY-09:00 | 28.00 | 14.40 |
June | 0.212544E+11 | 30695.17 | 12-JUN-04:03 | 20.00 | 10.45 | 0.206883E+10 | 2606.65 | 19-JUN-13:09 | 38.17 | 18.27 |
July | 0.206138E+11 | 30489.99 | 03-JUL-04:03 | 20.83 | 7.74 | 0.192273E+10 | 2606.68 | 05-JUL-09:09 | 31.33 | 16.71 |
August | 0.211166E+11 | 29912.03 | 30-AUG-05:03 | 21.83 | 17.25 | 0.215802E+10 | 2606.70 | 28-AUG-09:20 | 21.83 | 17.25 |
September | 0.186874E+11 | 31049.19 | 11-SEP-04:02 | 22.28 | 18.64 | 0.191705E+10 | 2606.67 | 22-SEP-09:09 | 24.00 | 17.33 |
October | 0.156291E+11 | 29971.90 | 06-OCT-05:03 | 19.00 | 10.35 | 0.198440E+10 | 2606.68 | 03-OCT-13:39 | 19.00 | 10.35 |
November | 0.119107E+11 | 20612.57 | 03-NOV-05:03 | 16.00 | 12.46 | 0.194899E+10 | 2606.70 | 22-NOV-10:00 | 20.00 | 11.57 |
December | 0.969361E+10 | 11371.75 | 26-DEC-17:00 | 23.00 | 10.75 | 0.183071E+10 | 2606.56 | 01-DEC-10:09 | 23.00 | 10.75 |
Annual Sum or Average | 0.185752E+12 | 0.236224E+11 | ||||||||
Minimum of Months | 0.884790E+10 | 11353.50 | 11.18 | 6.61 | 0.174062E+10 | 2606.56 | 11.18 | 7.43 | ||
Maximum of Months | 0.212544E+11 | 31049.19 | 26.00 | 18.64 | 0.215802E+10 | 2606.70 | 38.17 | 18.27 |
Report: ZoneCoolingSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.100330E+11 | 12351.00 | 27-JAN-17:00 | 26.00 | 9.22 | 0.185364E+10 | 2606.60 | 26-JAN-14:09 | 26.00 | 9.22 |
February | 0.823376E+10 | 10529.77 | 01-FEB-17:00 | 15.00 | 6.61 | 0.164655E+10 | 2606.52 | 02-FEB-14:00 | 15.00 | 6.61 |
March | 0.113167E+11 | 14483.53 | 17-MAR-16:00 | 26.60 | 14.13 | 0.204942E+10 | 2606.65 | 14-MAR-13:50 | 26.60 | 14.13 |
April | 0.165086E+11 | 32012.29 | 25-APR-05:03 | 22.00 | 11.73 | 0.190135E+10 | 2606.64 | 06-APR-09:30 | 22.00 | 11.73 |
May | 0.197808E+11 | 31811.66 | 08-MAY-04:03 | 22.00 | 10.09 | 0.207091E+10 | 2606.64 | 30-MAY-09:00 | 28.00 | 14.40 |
June | 0.235595E+11 | 33625.77 | 26-JUN-04:03 | 22.00 | 9.77 | 0.206918E+10 | 2606.65 | 19-JUN-13:09 | 22.00 | 9.77 |
July | 0.226796E+11 | 33415.84 | 05-JUL-04:02 | 23.00 | 11.62 | 0.192357E+10 | 2606.68 | 05-JUL-09:09 | 31.33 | 16.71 |
August | 0.226592E+11 | 33146.59 | 21-AUG-04:02 | 25.00 | 16.17 | 0.215806E+10 | 2606.71 | 28-AUG-09:30 | 32.50 | 20.80 |
September | 0.193825E+11 | 34596.36 | 11-SEP-04:02 | 22.28 | 18.64 | 0.191580E+10 | 2606.66 | 22-SEP-09:09 | 24.00 | 17.33 |
October | 0.147544E+11 | 32716.54 | 03-OCT-05:03 | 22.00 | 18.54 | 0.195443E+10 | 2606.65 | 03-OCT-13:30 | 33.00 | 20.21 |
November | 0.106332E+11 | 14824.06 | 01-NOV-16:00 | 28.00 | 15.72 | 0.188300E+10 | 2606.68 | 22-NOV-10:00 | 20.00 | 11.57 |
December | 0.852213E+10 | 10482.44 | 22-DEC-17:00 | 24.00 | 9.52 | 0.169291E+10 | 2606.53 | 22-DEC-14:00 | 24.00 | 9.52 |
Annual Sum or Average | 0.188063E+12 | 0.231188E+11 | ||||||||
Minimum of Months | 0.823376E+10 | 10482.44 | 15.00 | 6.61 | 0.164655E+10 | 2606.52 | 15.00 | 6.61 | ||
Maximum of Months | 0.235595E+11 | 34596.36 | 28.00 | 18.64 | 0.215806E+10 | 2606.71 | 33.00 | 20.80 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.178310E+10 | 2801.76 | 31-JAN-16:30 | 29.00 | 10.73 | 0.365831E+09 | 549.48 | 27-JAN-14:09 | 29.00 | 10.73 |
February | 0.137954E+10 | 2070.18 | 22-FEB-16:30 | 20.50 | 11.47 | 0.323229E+09 | 549.45 | 22-FEB-14:00 | 20.50 | 11.47 |
March | 0.225934E+10 | 4080.99 | 20-MAR-14:50 | 27.70 | 14.23 | 0.411314E+09 | 549.49 | 21-MAR-13:30 | 25.25 | 12.80 |
April | 0.434504E+10 | 6090.94 | 25-APR-14:50 | 32.67 | 15.01 | 0.396812E+09 | 549.49 | 06-APR-09:30 | 32.67 | 15.01 |
May | 0.597973E+10 | 10042.56 | 07-MAY-17:32 | 35.33 | 14.08 | 0.436577E+09 | 549.50 | 30-MAY-09:00 | 28.00 | 14.40 |
June | 0.844725E+10 | 12762.68 | 25-JUN-18:22 | 37.00 | 14.68 | 0.437193E+09 | 549.50 | 19-JUN-13:09 | 37.00 | 14.68 |
July | 0.768565E+10 | 13009.40 | 16-JUL-15:12 | 37.33 | 20.26 | 0.406624E+09 | 549.51 | 05-JUL-09:09 | 37.33 | 20.26 |
August | 0.725836E+10 | 12602.75 | 13-AUG-16:22 | 38.00 | 20.26 | 0.455514E+09 | 549.51 | 28-AUG-09:30 | 32.50 | 20.80 |
September | 0.581760E+10 | 12105.13 | 17-SEP-15:02 | 32.07 | 17.14 | 0.403911E+09 | 549.50 | 22-SEP-09:09 | 24.00 | 17.33 |
October | 0.344001E+10 | 10917.20 | 01-OCT-13:32 | 37.00 | 19.01 | 0.399659E+09 | 549.51 | 03-OCT-13:30 | 33.00 | 20.21 |
November | 0.197058E+10 | 4006.36 | 01-NOV-15:30 | 28.50 | 15.96 | 0.377620E+09 | 549.50 | 16-NOV-14:20 | 18.00 | 11.91 |
December | 0.127788E+10 | 1944.54 | 22-DEC-16:40 | 24.33 | 9.71 | 0.328823E+09 | 541.23 | 22-DEC-14:00 | 24.33 | 9.71 |
Annual Sum or Average | 0.516441E+11 | 0.474311E+10 | ||||||||
Minimum of Months | 0.127788E+10 | 1944.54 | 20.50 | 9.71 | 0.323229E+09 | 541.23 | 18.00 | 9.71 | ||
Maximum of Months | 0.844725E+10 | 13009.40 | 38.00 | 20.26 | 0.455514E+09 | 549.51 | 37.33 | 20.80 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.184998E+10 | 2806.21 | 27-JAN-10:30 | 21.00 | 7.83 | 0.249228E+09 | 347.87 | 09-JAN-10:09 | 21.00 | 7.83 |
February | 0.140149E+10 | 3023.44 | 23-FEB-10:30 | 15.00 | 11.05 | 0.220075E+09 | 347.87 | 23-FEB-10:09 | 15.00 | 11.05 |
March | 0.238730E+10 | 4361.68 | 23-MAR-10:30 | 22.70 | 10.73 | 0.273124E+09 | 347.88 | 14-MAR-13:50 | 22.70 | 10.73 |
April | 0.487078E+10 | 11052.46 | 30-APR-08:23 | 24.00 | 8.75 | 0.254663E+09 | 347.90 | 03-APR-09:20 | 24.00 | 8.75 |
May | 0.610171E+10 | 11897.64 | 14-MAY-10:02 | 28.50 | 10.70 | 0.277124E+09 | 348.17 | 11-MAY-09:00 | 28.50 | 10.70 |
June | 0.773567E+10 | 12198.37 | 18-JUN-09:42 | 33.67 | 17.70 | 0.276945E+09 | 348.13 | 08-JUN-09:00 | 33.67 | 17.70 |
July | 0.697828E+10 | 11895.24 | 23-JUL-09:32 | 32.67 | 22.21 | 0.257620E+09 | 348.10 | 28-JUL-09:00 | 31.00 | 20.55 |
August | 0.682430E+10 | 11973.20 | 13-AUG-09:42 | 32.83 | 21.13 | 0.288566E+09 | 348.17 | 30-AUG-09:00 | 33.00 | 19.22 |
September | 0.531825E+10 | 11216.48 | 10-SEP-10:22 | 32.45 | 19.22 | 0.255947E+09 | 348.37 | 08-SEP-09:00 | 32.45 | 19.22 |
October | 0.364385E+10 | 8875.99 | 01-OCT-13:32 | 37.00 | 19.01 | 0.260553E+09 | 347.89 | 17-OCT-09:20 | 24.67 | 9.84 |
November | 0.202665E+10 | 3615.69 | 01-NOV-10:20 | 23.67 | 16.07 | 0.251463E+09 | 347.89 | 22-NOV-10:00 | 20.00 | 11.57 |
December | 0.135328E+10 | 1814.22 | 25-DEC-15:52 | 26.00 | 12.00 | 0.222694E+09 | 347.86 | 22-DEC-14:00 | 26.00 | 12.00 |
Annual Sum or Average | 0.504915E+11 | 0.308800E+10 | ||||||||
Minimum of Months | 0.135328E+10 | 1814.22 | 15.00 | 7.83 | 0.220075E+09 | 347.86 | 15.00 | 7.83 | ||
Maximum of Months | 0.773567E+10 | 12198.37 | 37.00 | 22.21 | 0.288566E+09 | 348.37 | 33.67 | 20.55 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.599021E+10 | 14621.75 | 16-JAN-15:32 | 24.00 | 8.91 | 0.402072E+09 | 549.65 | 27-JAN-14:39 | 27.00 | 9.82 |
February | 0.327346E+10 | 9055.25 | 28-FEB-14:10 | 18.17 | 7.92 | 0.353060E+09 | 549.61 | 23-FEB-14:20 | 18.17 | 7.92 |
March | 0.414205E+10 | 8416.57 | 16-MAR-13:40 | 27.53 | 13.09 | 0.427429E+09 | 549.51 | 09-MAR-14:00 | 27.53 | 13.09 |
April | 0.640071E+10 | 14485.15 | 23-APR-14:02 | 33.83 | 12.77 | 0.397814E+09 | 549.93 | 25-APR-13:09 | 31.00 | 14.74 |
May | 0.662860E+10 | 13833.87 | 14-MAY-15:22 | 34.00 | 13.10 | 0.435781E+09 | 549.50 | 16-MAY-13:00 | 36.00 | 15.44 |
June | 0.821386E+10 | 13912.76 | 04-JUN-16:41 | 38.00 | 16.06 | 0.436830E+09 | 549.50 | 19-JUN-13:09 | 38.17 | 18.27 |
July | 0.792257E+10 | 14591.62 | 16-JUL-15:12 | 37.33 | 20.26 | 0.406467E+09 | 549.67 | 31-JUL-13:00 | 37.00 | 19.00 |
August | 0.858049E+10 | 14298.97 | 13-AUG-14:22 | 38.00 | 21.37 | 0.455594E+09 | 550.25 | 28-AUG-13:20 | 37.67 | 20.48 |
September | 0.816843E+10 | 14754.36 | 10-SEP-13:02 | 34.50 | 19.00 | 0.404516E+09 | 571.13 | 28-SEP-13:50 | 36.83 | 16.07 |
October | 0.728137E+10 | 15970.78 | 09-OCT-13:52 | 32.00 | 17.25 | 0.411191E+09 | 573.26 | 02-OCT-13:20 | 32.00 | 17.25 |
November | 0.560485E+10 | 14700.99 | 19-NOV-14:13 | 26.33 | 11.25 | 0.402562E+09 | 550.05 | 01-NOV-13:00 | 26.33 | 11.25 |
December | 0.436164E+10 | 15291.01 | 25-DEC-13:52 | 26.00 | 12.00 | 0.378168E+09 | 549.61 | 22-DEC-14:50 | 26.00 | 12.00 |
Annual Sum or Average | 0.765683E+11 | 0.491148E+10 | ||||||||
Minimum of Months | 0.327346E+10 | 8416.57 | 18.17 | 7.92 | 0.353060E+09 | 549.50 | 18.17 | 7.92 | ||
Maximum of Months | 0.858049E+10 | 15970.78 | 38.00 | 21.37 | 0.455594E+09 | 573.26 | 38.17 | 20.48 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.225320E+10 | 5678.23 | 31-JAN-16:30 | 29.00 | 10.73 | 0.230692E+09 | 347.84 | 24-JAN-14:00 | 29.00 | 10.73 |
February | 0.155660E+10 | 5594.53 | 22-FEB-16:30 | 20.50 | 11.47 | 0.203056E+09 | 347.83 | 27-FEB-14:00 | 17.00 | 9.60 |
March | 0.251782E+10 | 8221.46 | 18-MAR-17:08 | 26.92 | 12.85 | 0.254936E+09 | 347.85 | 09-MAR-14:00 | 26.92 | 12.85 |
April | 0.483442E+10 | 13487.49 | 30-APR-17:02 | 31.67 | 11.71 | 0.248491E+09 | 347.85 | 06-APR-09:39 | 31.67 | 11.71 |
May | 0.588673E+10 | 13713.05 | 28-MAY-17:12 | 32.67 | 12.64 | 0.274791E+09 | 347.85 | 30-MAY-09:00 | 28.00 | 14.40 |
June | 0.746054E+10 | 14095.46 | 25-JUN-17:01 | 38.00 | 15.28 | 0.276410E+09 | 347.85 | 19-JUN-13:00 | 38.00 | 15.28 |
July | 0.629537E+10 | 14058.17 | 16-JUL-17:11 | 36.67 | 21.11 | 0.257078E+09 | 347.86 | 05-JUL-09:09 | 36.67 | 21.11 |
August | 0.623088E+10 | 13896.87 | 13-AUG-17:02 | 38.00 | 19.94 | 0.287898E+09 | 347.86 | 28-AUG-09:30 | 32.50 | 20.80 |
September | 0.502039E+10 | 13208.71 | 04-SEP-15:52 | 31.60 | 21.45 | 0.254823E+09 | 347.85 | 13-SEP-09:09 | 27.98 | 18.77 |
October | 0.359448E+10 | 14006.81 | 15-OCT-16:22 | 30.50 | 12.33 | 0.249607E+09 | 347.86 | 03-OCT-13:30 | 30.50 | 12.33 |
November | 0.238228E+10 | 6913.23 | 01-NOV-16:00 | 28.00 | 15.72 | 0.236481E+09 | 347.85 | 16-NOV-14:20 | 18.00 | 11.91 |
December | 0.151994E+10 | 7846.93 | 25-DEC-16:33 | 24.67 | 11.46 | 0.212598E+09 | 347.84 | 22-DEC-14:39 | 24.67 | 11.46 |
Annual Sum or Average | 0.495527E+11 | 0.298686E+10 | ||||||||
Minimum of Months | 0.151994E+10 | 5594.53 | 20.50 | 10.73 | 0.203056E+09 | 347.83 | 17.00 | 9.60 | ||
Maximum of Months | 0.746054E+10 | 14095.46 | 38.00 | 21.45 | 0.287898E+09 | 347.86 | 38.00 | 21.11 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.197277E+10 | 2129.87 | 27-JAN-16:30 | 26.50 | 9.48 | 0.377317E+09 | 547.21 | 06-JAN-14:30 | 26.50 | 9.48 |
February | 0.152858E+10 | 1514.09 | 22-FEB-16:40 | 20.33 | 11.40 | 0.327864E+09 | 532.18 | 22-FEB-14:30 | 20.33 | 11.40 |
March | 0.204692E+10 | 2752.05 | 20-MAR-14:30 | 27.70 | 14.31 | 0.410929E+09 | 549.48 | 21-MAR-13:00 | 25.50 | 12.96 |
April | 0.345087E+10 | 4574.57 | 25-APR-14:50 | 32.67 | 15.01 | 0.398398E+09 | 549.49 | 14-APR-09:09 | 32.67 | 15.01 |
May | 0.464176E+10 | 5136.94 | 08-MAY-15:20 | 34.00 | 13.77 | 0.436017E+09 | 549.50 | 30-MAY-09:00 | 28.00 | 14.40 |
June | 0.686994E+10 | 8351.43 | 19-JUN-06:03 | 23.83 | 11.01 | 0.436599E+09 | 549.50 | 29-JUN-09:09 | 33.17 | 18.03 |
July | 0.702512E+10 | 10465.87 | 04-JUL-19:02 | 35.50 | 14.61 | 0.406338E+09 | 549.51 | 28-JUL-13:50 | 29.50 | 20.43 |
August | 0.700339E+10 | 10353.30 | 27-AUG-17:41 | 39.17 | 18.06 | 0.455552E+09 | 549.52 | 29-AUG-13:39 | 28.67 | 21.18 |
September | 0.622653E+10 | 8755.70 | 10-SEP-13:32 | 34.80 | 19.48 | 0.404751E+09 | 549.50 | 22-SEP-09:00 | 25.00 | 17.32 |
October | 0.392639E+10 | 8442.61 | 02-OCT-04:02 | 26.00 | 17.05 | 0.414530E+09 | 549.50 | 05-OCT-09:09 | 26.50 | 16.68 |
November | 0.241989E+10 | 3779.40 | 02-NOV-14:00 | 27.00 | 15.44 | 0.400276E+09 | 549.50 | 22-NOV-10:00 | 20.00 | 11.57 |
December | 0.182278E+10 | 2024.26 | 26-DEC-16:20 | 23.00 | 10.75 | 0.354470E+09 | 544.65 | 01-DEC-14:00 | 23.00 | 10.75 |
Annual Sum or Average | 0.489349E+11 | 0.482304E+10 | ||||||||
Minimum of Months | 0.152858E+10 | 1514.09 | 20.33 | 9.48 | 0.327864E+09 | 532.18 | 20.00 | 9.48 | ||
Maximum of Months | 0.702512E+10 | 10465.87 | 39.17 | 19.48 | 0.455552E+09 | 549.52 | 33.17 | 21.18 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.193876E+10 | 2784.79 | 27-JAN-10:30 | 21.00 | 7.83 | 0.257445E+09 | 347.87 | 11-JAN-10:09 | 21.00 | 7.83 |
February | 0.140638E+10 | 2500.59 | 23-FEB-10:30 | 15.00 | 11.05 | 0.226182E+09 | 347.87 | 23-FEB-10:09 | 15.00 | 11.05 |
March | 0.204790E+10 | 3436.77 | 23-MAR-10:30 | 22.70 | 10.73 | 0.277508E+09 | 347.88 | 17-MAR-09:00 | 22.70 | 10.73 |
April | 0.421255E+10 | 7988.69 | 23-APR-11:13 | 29.53 | 11.19 | 0.255285E+09 | 347.89 | 28-APR-09:00 | 25.00 | 10.77 |
May | 0.514357E+10 | 10151.23 | 14-MAY-10:02 | 28.50 | 10.70 | 0.277150E+09 | 348.02 | 30-MAY-09:30 | 27.50 | 13.85 |
June | 0.661922E+10 | 10290.80 | 18-JUN-07:12 | 29.33 | 16.72 | 0.276903E+09 | 348.05 | 02-JUN-09:50 | 29.33 | 16.72 |
July | 0.651827E+10 | 10829.34 | 04-JUL-09:42 | 31.67 | 15.19 | 0.257721E+09 | 347.99 | 13-JUL-09:50 | 31.83 | 20.83 |
August | 0.669220E+10 | 10584.19 | 27-AUG-11:02 | 37.17 | 17.45 | 0.288831E+09 | 348.02 | 01-AUG-09:00 | 37.17 | 17.45 |
September | 0.564294E+10 | 10568.20 | 04-SEP-09:42 | 26.33 | 22.09 | 0.256521E+09 | 347.98 | 05-SEP-09:00 | 27.20 | 20.54 |
October | 0.414454E+10 | 7512.27 | 02-OCT-04:02 | 26.00 | 17.05 | 0.265088E+09 | 347.89 | 17-OCT-09:30 | 25.00 | 10.00 |
November | 0.246597E+10 | 3841.52 | 10-NOV-10:00 | 23.00 | 9.98 | 0.260211E+09 | 347.89 | 22-NOV-10:00 | 20.00 | 11.57 |
December | 0.168465E+10 | 2470.25 | 01-DEC-10:30 | 18.50 | 8.87 | 0.242235E+09 | 347.87 | 13-DEC-10:09 | 11.33 | 10.45 |
Annual Sum or Average | 0.485170E+11 | 0.314108E+10 | ||||||||
Minimum of Months | 0.140638E+10 | 2470.25 | 15.00 | 7.83 | 0.226182E+09 | 347.87 | 11.33 | 7.83 | ||
Maximum of Months | 0.669220E+10 | 10829.34 | 37.17 | 22.09 | 0.288831E+09 | 348.05 | 37.17 | 20.83 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.531357E+10 | 12323.83 | 16-JAN-14:23 | 24.00 | 9.03 | 0.405660E+09 | 560.60 | 17-JAN-14:39 | 24.67 | 9.24 |
February | 0.207408E+10 | 7810.21 | 27-FEB-13:06 | 16.17 | 9.56 | 0.341512E+09 | 549.50 | 13-FEB-14:00 | 16.17 | 9.56 |
March | 0.296610E+10 | 9812.08 | 16-MAR-16:10 | 28.72 | 13.89 | 0.416020E+09 | 549.51 | 16-MAR-13:00 | 28.72 | 13.89 |
April | 0.605673E+10 | 11324.75 | 14-APR-16:50 | 35.00 | 14.56 | 0.397907E+09 | 629.19 | 14-APR-12:09 | 35.00 | 14.56 |
May | 0.684472E+10 | 11776.44 | 15-MAY-17:00 | 37.00 | 15.57 | 0.437463E+09 | 630.60 | 18-MAY-12:09 | 34.00 | 13.67 |
June | 0.926047E+10 | 13481.33 | 28-JUN-17:00 | 42.00 | 19.33 | 0.446129E+09 | 742.25 | 28-JUN-12:09 | 42.00 | 19.33 |
July | 0.934084E+10 | 12716.14 | 20-JUL-17:00 | 39.00 | 20.23 | 0.414523E+09 | 729.42 | 12-JUL-12:09 | 39.00 | 20.23 |
August | 0.104996E+11 | 13329.13 | 25-AUG-17:00 | 41.00 | 17.61 | 0.468114E+09 | 777.27 | 25-AUG-12:09 | 41.00 | 17.61 |
September | 0.990183E+10 | 12812.43 | 10-SEP-13:32 | 34.80 | 19.48 | 0.417467E+09 | 726.75 | 07-SEP-12:09 | 34.80 | 19.48 |
October | 0.795617E+10 | 13186.92 | 09-OCT-13:42 | 31.83 | 17.27 | 0.423000E+09 | 705.32 | 02-OCT-12:09 | 31.83 | 17.27 |
November | 0.555085E+10 | 12381.61 | 19-NOV-14:23 | 26.50 | 11.30 | 0.408078E+09 | 584.38 | 20-NOV-14:39 | 27.00 | 11.68 |
December | 0.395723E+10 | 12326.73 | 24-DEC-13:43 | 23.83 | 10.31 | 0.378883E+09 | 556.85 | 26-DEC-14:09 | 23.00 | 10.20 |
Annual Sum or Average | 0.797222E+11 | 0.495476E+10 | ||||||||
Minimum of Months | 0.207408E+10 | 7810.21 | 16.17 | 9.03 | 0.341512E+09 | 549.50 | 16.17 | 9.24 | ||
Maximum of Months | 0.104996E+11 | 13481.33 | 42.00 | 20.23 | 0.468114E+09 | 777.27 | 42.00 | 20.23 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.215401E+10 | 4744.83 | 24-JAN-16:40 | 24.33 | 10.79 | 0.246250E+09 | 347.84 | 23-JAN-14:00 | 24.33 | 10.79 |
February | 0.145481E+10 | 4067.97 | 22-FEB-16:30 | 20.50 | 11.47 | 0.211879E+09 | 347.83 | 02-FEB-14:00 | 20.50 | 11.47 |
March | 0.203381E+10 | 4830.67 | 18-MAR-17:10 | 26.92 | 12.85 | 0.263587E+09 | 347.84 | 21-MAR-13:00 | 25.50 | 12.96 |
April | 0.400893E+10 | 11083.91 | 16-APR-17:42 | 26.00 | 13.93 | 0.253648E+09 | 347.85 | 06-APR-09:30 | 26.00 | 13.93 |
May | 0.480690E+10 | 11026.58 | 21-MAY-17:51 | 31.00 | 13.11 | 0.276503E+09 | 347.85 | 30-MAY-09:00 | 28.00 | 14.40 |
June | 0.631184E+10 | 11274.87 | 25-JUN-17:41 | 38.00 | 15.02 | 0.276659E+09 | 347.85 | 29-JUN-09:09 | 33.17 | 18.03 |
July | 0.577212E+10 | 11229.66 | 04-JUL-19:02 | 35.50 | 14.61 | 0.257452E+09 | 347.86 | 28-JUL-13:50 | 29.50 | 20.43 |
August | 0.603270E+10 | 11769.39 | 27-AUG-17:41 | 39.17 | 18.06 | 0.288629E+09 | 347.87 | 29-AUG-13:39 | 28.67 | 21.18 |
September | 0.526560E+10 | 11379.59 | 04-SEP-17:42 | 31.60 | 21.23 | 0.256434E+09 | 347.85 | 15-SEP-09:09 | 25.45 | 16.44 |
October | 0.384966E+10 | 10954.49 | 09-OCT-15:02 | 32.17 | 17.27 | 0.263123E+09 | 347.85 | 16-OCT-09:30 | 25.50 | 10.18 |
November | 0.260992E+10 | 6281.58 | 21-NOV-16:30 | 24.50 | 10.75 | 0.256146E+09 | 347.86 | 22-NOV-10:00 | 20.00 | 11.57 |
December | 0.181455E+10 | 7135.50 | 25-DEC-16:42 | 24.33 | 11.32 | 0.231406E+09 | 347.83 | 19-DEC-14:00 | 24.33 | 11.32 |
Annual Sum or Average | 0.461148E+11 | 0.308172E+10 | ||||||||
Minimum of Months | 0.145481E+10 | 4067.97 | 20.50 | 10.75 | 0.211879E+09 | 347.83 | 20.00 | 10.18 | ||
Maximum of Months | 0.631184E+10 | 11769.39 | 39.17 | 21.23 | 0.288629E+09 | 347.87 | 33.17 | 21.18 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.201688E+10 | 2754.71 | 31-JAN-16:30 | 29.00 | 10.73 | 0.383266E+09 | 549.49 | 06-JAN-14:09 | 29.00 | 10.73 |
February | 0.157713E+10 | 2026.07 | 22-FEB-16:30 | 20.50 | 11.47 | 0.339898E+09 | 549.46 | 16-FEB-14:00 | 20.50 | 11.47 |
March | 0.237595E+10 | 3869.84 | 20-MAR-14:30 | 27.70 | 14.31 | 0.427461E+09 | 549.49 | 17-MAR-09:00 | 27.70 | 14.31 |
April | 0.415204E+10 | 5427.66 | 25-APR-14:50 | 32.67 | 15.01 | 0.400846E+09 | 549.50 | 06-APR-09:30 | 32.67 | 15.01 |
May | 0.559557E+10 | 6400.89 | 08-MAY-06:03 | 20.50 | 9.41 | 0.437264E+09 | 549.50 | 30-MAY-09:00 | 28.00 | 14.40 |
June | 0.761297E+10 | 10715.40 | 25-JUN-18:11 | 37.33 | 14.77 | 0.437200E+09 | 549.73 | 28-JUN-13:30 | 40.50 | 19.31 |
July | 0.695544E+10 | 10663.95 | 04-JUL-19:02 | 35.50 | 14.61 | 0.406552E+09 | 549.51 | 05-JUL-09:09 | 31.33 | 16.71 |
August | 0.670277E+10 | 10490.65 | 27-AUG-15:51 | 40.00 | 18.27 | 0.455589E+09 | 549.51 | 28-AUG-09:30 | 32.50 | 20.80 |
September | 0.551312E+10 | 9856.39 | 10-SEP-13:32 | 34.80 | 19.48 | 0.404488E+09 | 549.50 | 22-SEP-09:09 | 24.00 | 17.33 |
October | 0.350189E+10 | 8784.33 | 02-OCT-04:02 | 26.00 | 17.05 | 0.410097E+09 | 549.52 | 03-OCT-13:39 | 33.00 | 20.21 |
November | 0.220035E+10 | 3728.12 | 02-NOV-14:00 | 27.00 | 15.44 | 0.393410E+09 | 549.50 | 22-NOV-10:00 | 20.00 | 11.57 |
December | 0.164242E+10 | 1982.89 | 22-DEC-16:50 | 24.17 | 9.62 | 0.347326E+09 | 543.39 | 01-DEC-14:00 | 24.17 | 9.62 |
Annual Sum or Average | 0.498465E+11 | 0.484340E+10 | ||||||||
Minimum of Months | 0.157713E+10 | 1982.89 | 20.50 | 9.41 | 0.339898E+09 | 543.39 | 20.00 | 9.62 | ||
Maximum of Months | 0.761297E+10 | 10715.40 | 40.00 | 19.48 | 0.455589E+09 | 549.73 | 40.50 | 20.80 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.204571E+10 | 3340.65 | 27-JAN-10:00 | 20.00 | 7.78 | 0.186831E+09 | 338.73 | 09-JAN-09:09 | 20.00 | 7.78 |
February | 0.156728E+10 | 3493.04 | 23-FEB-10:00 | 14.00 | 11.11 | 0.165926E+09 | 338.72 | 16-FEB-16:10 | 14.00 | 11.11 |
March | 0.245864E+10 | 4539.29 | 23-MAR-10:20 | 22.33 | 10.61 | 0.204159E+09 | 338.73 | 16-MAR-10:09 | 22.33 | 10.61 |
April | 0.462800E+10 | 11265.88 | 30-APR-08:52 | 25.00 | 9.17 | 0.188718E+09 | 338.74 | 28-APR-10:09 | 25.00 | 9.17 |
May | 0.566370E+10 | 11711.88 | 29-MAY-09:12 | 26.67 | 11.70 | 0.205063E+09 | 339.36 | 30-MAY-10:30 | 28.50 | 14.02 |
June | 0.700768E+10 | 11807.51 | 25-JUN-08:12 | 29.00 | 13.68 | 0.204729E+09 | 343.84 | 19-JUN-07:19 | 29.00 | 13.68 |
July | 0.631717E+10 | 11869.61 | 04-JUL-09:42 | 31.67 | 15.19 | 0.191031E+09 | 340.77 | 10-JUL-07:19 | 28.00 | 18.16 |
August | 0.624949E+10 | 11719.76 | 27-AUG-08:32 | 31.67 | 15.27 | 0.213203E+09 | 339.55 | 28-AUG-10:30 | 35.00 | 21.28 |
September | 0.497753E+10 | 11457.46 | 04-SEP-09:42 | 26.33 | 22.09 | 0.189588E+09 | 339.54 | 05-SEP-10:30 | 28.00 | 20.78 |
October | 0.364572E+10 | 7661.01 | 01-OCT-11:23 | 34.50 | 19.32 | 0.194109E+09 | 338.74 | 04-OCT-07:30 | 23.00 | 17.79 |
November | 0.219925E+10 | 4081.17 | 10-NOV-09:40 | 22.33 | 9.69 | 0.188553E+09 | 338.74 | 22-NOV-11:09 | 19.33 | 11.05 |
December | 0.158791E+10 | 2424.60 | 26-DEC-10:00 | 18.00 | 7.98 | 0.170563E+09 | 338.71 | 29-DEC-11:30 | 17.50 | 8.08 |
Annual Sum or Average | 0.483481E+11 | 0.230247E+10 | ||||||||
Minimum of Months | 0.156728E+10 | 2424.60 | 14.00 | 7.78 | 0.165926E+09 | 338.71 | 14.00 | 7.78 | ||
Maximum of Months | 0.700768E+10 | 11869.61 | 34.50 | 22.09 | 0.213203E+09 | 343.84 | 35.00 | 21.28 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.627507E+10 | 12810.12 | 15-JAN-13:13 | 21.67 | 10.16 | 0.411576E+09 | 564.21 | 30-JAN-14:39 | 24.67 | 9.55 |
February | 0.349432E+10 | 8824.02 | 28-FEB-14:10 | 18.17 | 7.92 | 0.365038E+09 | 549.74 | 23-FEB-14:50 | 18.17 | 7.92 |
March | 0.422178E+10 | 7958.10 | 23-MAR-13:50 | 25.42 | 11.73 | 0.440361E+09 | 549.63 | 16-MAR-13:00 | 25.42 | 11.73 |
April | 0.602217E+10 | 12325.41 | 23-APR-13:43 | 33.67 | 12.69 | 0.402041E+09 | 550.07 | 25-APR-13:30 | 31.00 | 14.65 |
May | 0.611809E+10 | 10676.80 | 07-MAY-14:32 | 35.00 | 13.93 | 0.437274E+09 | 549.50 | 30-MAY-09:00 | 28.00 | 14.40 |
June | 0.735807E+10 | 11792.07 | 25-JUN-16:51 | 38.00 | 15.34 | 0.436993E+09 | 549.66 | 30-JUN-13:50 | 39.83 | 18.96 |
July | 0.711300E+10 | 11711.50 | 30-JUL-15:42 | 38.00 | 18.94 | 0.406579E+09 | 549.77 | 19-JUL-13:50 | 38.00 | 18.94 |
August | 0.787511E+10 | 12392.38 | 27-AUG-11:52 | 38.00 | 17.92 | 0.455852E+09 | 550.61 | 28-AUG-13:30 | 37.50 | 20.42 |
September | 0.769315E+10 | 13156.00 | 10-SEP-13:32 | 34.80 | 19.48 | 0.405394E+09 | 584.09 | 28-SEP-13:50 | 36.83 | 16.07 |
October | 0.720744E+10 | 12792.99 | 09-OCT-11:23 | 28.00 | 15.84 | 0.418336E+09 | 587.39 | 02-OCT-13:09 | 28.00 | 15.84 |
November | 0.587777E+10 | 13014.30 | 05-NOV-13:42 | 22.00 | 8.01 | 0.410767E+09 | 568.91 | 01-NOV-13:00 | 22.00 | 8.01 |
December | 0.487700E+10 | 13337.48 | 25-DEC-13:52 | 26.00 | 12.00 | 0.389870E+09 | 551.86 | 27-DEC-14:09 | 19.17 | 9.79 |
Annual Sum or Average | 0.741330E+11 | 0.498008E+10 | ||||||||
Minimum of Months | 0.349432E+10 | 7958.10 | 18.17 | 7.92 | 0.365038E+09 | 549.50 | 18.17 | 7.92 | ||
Maximum of Months | 0.787511E+10 | 13337.48 | 38.00 | 19.48 | 0.455852E+09 | 587.39 | 39.83 | 20.42 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.238388E+10 | 5703.78 | 29-JAN-17:13 | 23.00 | 8.84 | 0.241247E+09 | 347.85 | 06-JAN-14:09 | 23.00 | 8.84 |
February | 0.169389E+10 | 5421.08 | 22-FEB-16:30 | 20.50 | 11.47 | 0.212798E+09 | 347.84 | 03-FEB-14:00 | 20.50 | 11.47 |
March | 0.252155E+10 | 7032.58 | 18-MAR-17:08 | 26.92 | 12.85 | 0.266274E+09 | 347.85 | 14-MAR-13:00 | 26.92 | 12.85 |
April | 0.452920E+10 | 12638.32 | 30-APR-17:31 | 30.67 | 11.39 | 0.252881E+09 | 347.85 | 06-APR-09:30 | 30.67 | 11.39 |
May | 0.544868E+10 | 12269.11 | 29-MAY-17:11 | 31.67 | 13.84 | 0.276418E+09 | 347.85 | 30-MAY-09:00 | 28.00 | 14.40 |
June | 0.678038E+10 | 12569.43 | 25-JUN-16:52 | 38.00 | 15.34 | 0.276658E+09 | 347.85 | 29-JUN-09:09 | 33.17 | 18.03 |
July | 0.569781E+10 | 12134.96 | 30-JUL-17:02 | 38.00 | 19.22 | 0.257248E+09 | 347.86 | 05-JUL-09:09 | 38.00 | 19.22 |
August | 0.573364E+10 | 12565.95 | 06-AUG-17:42 | 30.17 | 18.68 | 0.288303E+09 | 347.86 | 28-AUG-09:30 | 32.50 | 20.80 |
September | 0.471497E+10 | 12276.27 | 04-SEP-17:42 | 31.60 | 21.23 | 0.255814E+09 | 347.85 | 22-SEP-09:09 | 24.00 | 17.33 |
October | 0.353263E+10 | 8896.76 | 01-OCT-16:42 | 32.50 | 20.08 | 0.257288E+09 | 347.86 | 03-OCT-13:39 | 33.00 | 20.21 |
November | 0.249579E+10 | 6552.20 | 01-NOV-16:00 | 28.00 | 15.72 | 0.246713E+09 | 347.86 | 16-NOV-14:09 | 18.00 | 11.84 |
December | 0.177914E+10 | 8480.51 | 25-DEC-16:33 | 24.67 | 11.46 | 0.222146E+09 | 347.83 | 20-DEC-14:00 | 24.67 | 11.46 |
Annual Sum or Average | 0.473116E+11 | 0.305379E+10 | ||||||||
Minimum of Months | 0.169389E+10 | 5421.08 | 20.50 | 8.84 | 0.212798E+09 | 347.83 | 18.00 | 8.84 | ||
Maximum of Months | 0.678038E+10 | 12638.32 | 38.00 | 21.23 | 0.288303E+09 | 347.86 | 38.00 | 20.80 |
Report: ZoneHeatingSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 4.27 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 11.90 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 11.85 |
April | 0.00 | 0.00 | 01-APR-00:10 | 15.28 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 19.10 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 25.83 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 27.73 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.40 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.22 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 25.15 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 17.23 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 9.20 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 4.27 | |
Maximum of Months | 0.00 | 0.00 | 29.40 |
Report: ZoneHeatingSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.893879E+09 | 7653.36 | 02-JAN-07:02 | 6.00 |
February | 0.768887E+09 | 4240.62 | 13-FEB-07:02 | 8.33 |
March | 0.774343E+09 | 6090.80 | 27-MAR-06:01 | 1.97 |
April | 0.322649E+09 | 5794.56 | 24-APR-05:03 | 15.17 |
May | 0.169379E+09 | 6808.92 | 22-MAY-05:03 | 15.17 |
June | 42296433.96 | 5281.69 | 19-JUN-04:02 | 22.83 |
July | 30230283.56 | 5144.80 | 05-JUL-04:02 | 23.00 |
August | 30412338.43 | 4763.67 | 21-AUG-04:02 | 25.00 |
September | 46662542.23 | 4794.14 | 11-SEP-04:02 | 22.28 |
October | 0.463394E+09 | 5043.52 | 10-OCT-05:03 | 17.67 |
November | 0.654522E+09 | 5673.89 | 24-NOV-07:01 | 4.50 |
December | 0.131166E+10 | 9050.37 | 07-DEC-07:02 | 1.33 |
Annual Sum or Average | 0.550831E+10 | |||
Minimum of Months | 30230283.56 | 4240.62 | 1.33 | |
Maximum of Months | 0.131166E+10 | 9050.37 | 25.00 |
Report: ZoneHeatingSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.271169E+09 | 3393.53 | 16-JAN-12:53 | 24.00 |
February | 0.335723E+09 | 2859.05 | 20-FEB-15:45 | 18.00 |
March | 0.183988E+09 | 2540.47 | 26-MAR-13:23 | 16.90 |
April | 23977377.71 | 2687.86 | 02-APR-15:42 | 31.00 |
May | 19066011.13 | 1685.97 | 07-MAY-14:32 | 35.00 |
June | 17427541.69 | 2330.83 | 25-JUN-16:11 | 38.00 |
July | 19958124.69 | 2548.13 | 02-JUL-16:31 | 38.00 |
August | 17935929.19 | 2500.24 | 27-AUG-15:11 | 40.00 |
September | 17361068.72 | 1962.26 | 07-SEP-04:02 | 26.10 |
October | 40244258.71 | 2905.05 | 29-OCT-13:53 | 25.00 |
November | 0.134110E+09 | 3788.28 | 26-NOV-12:33 | 18.00 |
December | 0.609205E+09 | 4400.95 | 25-DEC-16:33 | 24.67 |
Annual Sum or Average | 0.169016E+10 | |||
Minimum of Months | 17361068.72 | 1685.97 | 16.90 | |
Maximum of Months | 0.609205E+09 | 4400.95 | 40.00 |
Report: ZoneHeatingSummaryMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.106285E+09 | 4524.10 | 12-JAN-06:02 | 5.83 |
February | 91642681.94 | 4350.14 | 01-FEB-06:02 | 5.00 |
March | 30230542.50 | 3876.18 | 24-MAR-05:03 | 6.70 |
April | 21838027.45 | 3746.56 | 21-APR-05:03 | 8.17 |
May | 20500466.06 | 2214.75 | 22-MAY-04:03 | 15.00 |
June | 18295903.22 | 2865.82 | 30-JUN-04:02 | 27.83 |
July | 26366435.84 | 3429.31 | 12-JUL-04:02 | 27.83 |
August | 26845381.49 | 3407.28 | 16-AUG-04:02 | 28.17 |
September | 29496593.52 | 3815.89 | 07-SEP-04:02 | 26.10 |
October | 37582196.34 | 4730.60 | 26-OCT-05:03 | 7.17 |
November | 41503176.79 | 5721.29 | 24-NOV-06:02 | 3.17 |
December | 0.208393E+09 | 4937.63 | 29-DEC-06:02 | 6.00 |
Annual Sum or Average | 0.658979E+09 | |||
Minimum of Months | 18295903.22 | 2214.75 | 3.17 | |
Maximum of Months | 0.208393E+09 | 5721.29 | 28.17 |
Report: ZoneHeatingSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 4.27 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 11.90 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 11.85 |
April | 0.00 | 0.00 | 01-APR-00:10 | 15.28 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 19.10 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 25.83 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 27.73 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.40 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.22 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 25.15 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 17.23 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 9.20 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 4.27 | |
Maximum of Months | 0.00 | 0.00 | 29.40 |
Report: ZoneHeatingSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 26938989.53 | 23859.07 | 02-JAN-06:01 | 4.33 |
February | 9391724.35 | 22880.70 | 13-FEB-07:02 | 8.33 |
March | 1500389.55 | 22505.84 | 27-MAR-06:01 | 1.97 |
April | 0.00 | 0.00 | 01-APR-00:10 | 15.28 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 19.10 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 25.83 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 27.73 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.40 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.22 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 25.15 |
November | 1877645.04 | 21905.86 | 24-NOV-07:01 | 4.50 |
December | 56615964.13 | 23284.77 | 07-DEC-07:01 | 1.33 |
Annual Sum or Average | 96324712.61 | |||
Minimum of Months | 0.00 | 0.00 | 1.33 | |
Maximum of Months | 56615964.13 | 23859.07 | 29.40 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.105510E+09 | 10188.31 | 02-JAN-06:01 | 4.33 |
February | 97357038.59 | 9327.44 | 13-FEB-06:03 | 8.00 |
March | 64653725.83 | 9349.60 | 27-MAR-05:02 | 2.52 |
April | 0.00 | 0.00 | 01-APR-00:10 | 15.28 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 19.10 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 25.83 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 27.73 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.40 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.22 |
October | 6632899.65 | 8747.12 | 26-OCT-06:02 | 8.17 |
November | 56070367.32 | 9395.02 | 24-NOV-06:02 | 3.17 |
December | 0.398350E+09 | 10074.48 | 18-DEC-06:01 | 3.83 |
Annual Sum or Average | 0.728574E+09 | |||
Minimum of Months | 0.00 | 0.00 | 2.52 | |
Maximum of Months | 0.398350E+09 | 10188.31 | 29.40 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 47879617.72 | 7369.39 | 02-JAN-06:01 | 4.33 |
February | 41529459.03 | 6625.33 | 13-FEB-06:03 | 8.00 |
March | 28866315.98 | 6705.78 | 27-MAR-05:02 | 2.52 |
April | 0.00 | 0.00 | 01-APR-00:10 | 15.28 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 19.10 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 25.83 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 27.73 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.40 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.22 |
October | 5281268.47 | 6103.44 | 26-OCT-06:02 | 8.17 |
November | 19786178.11 | 6654.66 | 24-NOV-06:02 | 3.17 |
December | 0.169378E+09 | 7260.91 | 18-DEC-06:01 | 3.83 |
Annual Sum or Average | 0.312721E+09 | |||
Minimum of Months | 0.00 | 0.00 | 2.52 | |
Maximum of Months | 0.169378E+09 | 7369.39 | 29.40 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 47971132.45 | 10874.99 | 02-JAN-06:01 | 4.33 |
February | 53924348.03 | 9873.51 | 13-FEB-07:02 | 8.33 |
March | 45662396.07 | 9910.04 | 27-MAR-06:01 | 1.97 |
April | 0.00 | 0.00 | 01-APR-00:10 | 15.28 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 19.10 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 25.83 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 27.73 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.40 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.22 |
October | 3255149.80 | 7910.06 | 26-OCT-06:02 | 8.17 |
November | 21110256.23 | 9817.14 | 24-NOV-07:01 | 4.50 |
December | 0.202565E+09 | 10884.18 | 07-DEC-06:01 | -0.7 |
Annual Sum or Average | 0.374488E+09 | |||
Minimum of Months | 0.00 | 0.00 | -0.7 | |
Maximum of Months | 0.202565E+09 | 10884.18 | 29.40 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 62690267.08 | 7121.45 | 02-JAN-06:01 | 4.33 |
February | 61758647.81 | 6763.85 | 13-FEB-06:03 | 8.00 |
March | 38866547.28 | 6274.63 | 13-MAR-06:02 | 5.92 |
April | 6927.72 | 46.18 | 21-APR-06:03 | 9.33 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 19.10 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 25.83 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 27.73 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.40 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.22 |
October | 6078804.26 | 6321.86 | 25-OCT-06:01 | 5.00 |
November | 33334347.57 | 6630.70 | 24-NOV-06:02 | 3.17 |
December | 0.244030E+09 | 7102.22 | 18-DEC-06:01 | 3.83 |
Annual Sum or Average | 0.446766E+09 | |||
Minimum of Months | 0.00 | 0.00 | 3.17 | |
Maximum of Months | 0.244030E+09 | 7121.45 | 29.40 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 9993192.11 | 6289.39 | 02-JAN-06:01 | 4.33 |
February | 6365319.22 | 6091.62 | 14-FEB-07:02 | 7.33 |
March | 6728690.77 | 6102.09 | 27-MAR-06:01 | 1.97 |
April | 0.00 | 0.00 | 01-APR-00:10 | 15.28 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 19.10 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 25.83 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 27.73 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.40 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.22 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 25.15 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 17.23 |
December | 10519282.98 | 6104.42 | 07-DEC-07:01 | 1.33 |
Annual Sum or Average | 33606485.09 | |||
Minimum of Months | 0.00 | 0.00 | 1.33 | |
Maximum of Months | 10519282.98 | 6289.39 | 29.40 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 1701241.17 | 3611.14 | 02-JAN-07:02 | 6.00 |
February | 1714334.62 | 3706.15 | 13-FEB-07:02 | 8.33 |
March | 637154.31 | 3663.88 | 27-MAR-06:01 | 1.97 |
April | 0.00 | 0.00 | 01-APR-00:10 | 15.28 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 19.10 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 25.83 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 27.73 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.40 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.22 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 25.15 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 17.23 |
December | 1954607.60 | 3918.14 | 18-DEC-07:01 | 3.33 |
Annual Sum or Average | 6007337.70 | |||
Minimum of Months | 0.00 | 0.00 | 1.97 | |
Maximum of Months | 1954607.60 | 3918.14 | 29.40 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.458864E+09 | 6935.66 | 02-JAN-07:10 | 6.00 |
February | 0.508293E+09 | 7062.68 | 08-FEB-07:10 | 6.17 |
March | 0.571297E+09 | 7663.43 | 27-MAR-06:10 | 1.97 |
April | 95664798.16 | 6263.94 | 21-APR-06:10 | 9.33 |
May | 4462913.36 | 5436.99 | 01-MAY-06:05 | 13.50 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 25.83 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 27.73 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.40 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.22 |
October | 0.187154E+09 | 6729.94 | 25-OCT-06:10 | 5.00 |
November | 0.257116E+09 | 6790.07 | 24-NOV-07:10 | 4.50 |
December | 0.566714E+09 | 7955.98 | 06-DEC-07:10 | -0.5 |
Annual Sum or Average | 0.264956E+10 | |||
Minimum of Months | 0.00 | 0.00 | -0.5 | |
Maximum of Months | 0.571297E+09 | 7955.98 | 29.40 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 2002387.95 | 3611.23 | 02-JAN-07:02 | 6.00 |
February | 2780656.48 | 3944.68 | 08-FEB-07:02 | 6.17 |
March | 656224.55 | 3706.56 | 27-MAR-06:01 | 1.97 |
April | 0.00 | 0.00 | 01-APR-00:10 | 15.28 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 19.10 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 25.83 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 27.73 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.40 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.22 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 25.15 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 17.23 |
December | 2856161.34 | 3590.63 | 18-DEC-07:01 | 3.33 |
Annual Sum or Average | 8295430.32 | |||
Minimum of Months | 0.00 | 0.00 | 1.97 | |
Maximum of Months | 2856161.34 | 3944.68 | 29.40 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 12902252.01 | 7826.57 | 02-JAN-06:01 | 4.33 |
February | 6151631.95 | 7384.33 | 13-FEB-07:02 | 8.33 |
March | 3936370.23 | 7531.43 | 27-MAR-06:01 | 1.97 |
April | 0.00 | 0.00 | 01-APR-00:10 | 15.28 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 19.10 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 25.83 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 27.73 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.40 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.22 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 25.15 |
November | 1524421.90 | 7385.52 | 24-NOV-07:01 | 4.50 |
December | 46755075.19 | 7566.75 | 06-DEC-07:01 | -0.5 |
Annual Sum or Average | 71269751.29 | |||
Minimum of Months | 0.00 | 0.00 | -0.5 | |
Maximum of Months | 46755075.19 | 7826.57 | 29.40 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 6446211.42 | 4839.86 | 03-JAN-07:03 | 10.33 |
February | 4755142.39 | 4848.44 | 14-FEB-07:02 | 7.33 |
March | 2441448.66 | 4657.33 | 28-MAR-06:01 | 3.90 |
April | 0.00 | 0.00 | 01-APR-00:10 | 15.28 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 19.10 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 25.83 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 27.73 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.40 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.22 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 25.15 |
November | 667689.96 | 4309.25 | 24-NOV-07:01 | 4.50 |
December | 20740341.97 | 4923.80 | 07-DEC-06:01 | -0.7 |
Annual Sum or Average | 35050834.40 | |||
Minimum of Months | 0.00 | 0.00 | -0.7 | |
Maximum of Months | 20740341.97 | 4923.80 | 29.40 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 3296201.82 | 7221.22 | 02-JAN-07:02 | 6.00 |
February | 2746011.36 | 7181.01 | 13-FEB-07:02 | 8.33 |
March | 1126462.69 | 7184.72 | 27-MAR-06:01 | 1.97 |
April | 0.00 | 0.00 | 01-APR-00:10 | 15.28 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 19.10 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 25.83 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 27.73 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.40 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.22 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 25.15 |
November | 143272.08 | 1671.51 | 24-NOV-07:01 | 4.50 |
December | 15493737.27 | 7374.75 | 06-DEC-07:01 | -0.5 |
Annual Sum or Average | 22805685.22 | |||
Minimum of Months | 0.00 | 0.00 | -0.5 | |
Maximum of Months | 15493737.27 | 7374.75 | 29.40 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 6906855.50 | 4918.69 | 02-JAN-06:01 | 4.33 |
February | 5411922.98 | 4665.43 | 14-FEB-07:02 | 7.33 |
March | 2226247.69 | 4309.21 | 28-MAR-06:01 | 3.90 |
April | 0.00 | 0.00 | 01-APR-00:10 | 15.28 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 19.10 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 25.83 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 27.73 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.40 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 26.22 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 25.15 |
November | 754751.83 | 4367.80 | 24-NOV-07:01 | 4.50 |
December | 31191137.45 | 4797.50 | 09-DEC-07:03 | 8.17 |
Annual Sum or Average | 46490915.45 | |||
Minimum of Months | 0.00 | 0.00 | 3.90 | |
Maximum of Months | 31191137.45 | 4918.69 | 29.40 |
Report: ZoneElectricSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.403280E+10 | 4220.20 | 02-JAN-08:09 | 0.198672E+11 | 18185.19 | 02-JAN-08:09 |
February | 0.365805E+10 | 4220.20 | 01-FEB-08:09 | 0.179823E+11 | 18185.19 | 01-FEB-08:09 |
March | 0.434679E+10 | 4220.20 | 01-MAR-08:09 | 0.207117E+11 | 18185.19 | 01-MAR-08:09 |
April | 0.388256E+10 | 4220.20 | 03-APR-07:10 | 0.191625E+11 | 18185.19 | 03-APR-07:10 |
May | 0.418979E+10 | 4220.20 | 01-MAY-07:10 | 0.202894E+11 | 18185.19 | 01-MAY-07:10 |
June | 0.416954E+10 | 4220.20 | 01-JUN-07:10 | 0.199404E+11 | 18185.19 | 01-JUN-07:10 |
July | 0.390282E+10 | 4220.20 | 03-JUL-07:10 | 0.195094E+11 | 18185.19 | 03-JUL-07:10 |
August | 0.434679E+10 | 4220.20 | 01-AUG-07:10 | 0.207117E+11 | 18185.19 | 01-AUG-07:10 |
September | 0.388256E+10 | 4220.20 | 01-SEP-07:10 | 0.191582E+11 | 18185.19 | 01-SEP-07:10 |
October | 0.403280E+10 | 4220.20 | 02-OCT-07:10 | 0.198694E+11 | 18185.19 | 02-OCT-07:10 |
November | 0.398554E+10 | 4220.20 | 01-NOV-07:10 | 0.194582E+11 | 18185.19 | 01-NOV-07:10 |
December | 0.390282E+10 | 4220.20 | 01-DEC-08:09 | 0.195072E+11 | 18185.19 | 01-DEC-08:09 |
Annual Sum or Average | 0.483329E+11 | 0.236167E+12 | ||||
Minimum of Months | 0.365805E+10 | 4220.20 | 0.179823E+11 | 18185.19 | ||
Maximum of Months | 0.434679E+10 | 4220.20 | 0.207117E+11 | 18185.19 |
Report: ZoneElectricSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.403280E+10 | 4220.20 | 02-JAN-08:09 | 0.971303E+10 | 6808.32 | 02-JAN-08:09 |
February | 0.365805E+10 | 4220.20 | 01-FEB-08:09 | 0.879311E+10 | 6808.32 | 01-FEB-08:09 |
March | 0.434679E+10 | 4220.20 | 01-MAR-08:09 | 0.101015E+11 | 6808.32 | 01-MAR-08:09 |
April | 0.388256E+10 | 4220.20 | 03-APR-07:10 | 0.937947E+10 | 6808.32 | 03-APR-07:10 |
May | 0.418979E+10 | 4220.20 | 01-MAY-07:10 | 0.990724E+10 | 6808.32 | 01-MAY-07:10 |
June | 0.416954E+10 | 4220.20 | 01-JUN-07:10 | 0.972788E+10 | 6808.32 | 01-JUN-07:10 |
July | 0.390282E+10 | 4220.20 | 03-JUL-07:10 | 0.955663E+10 | 6808.32 | 03-JUL-07:10 |
August | 0.434679E+10 | 4220.20 | 01-AUG-07:10 | 0.101015E+11 | 6808.32 | 01-AUG-07:10 |
September | 0.388256E+10 | 4220.20 | 01-SEP-07:10 | 0.937507E+10 | 6808.32 | 01-SEP-07:10 |
October | 0.403280E+10 | 4220.20 | 02-OCT-07:10 | 0.971523E+10 | 6808.32 | 02-OCT-07:10 |
November | 0.398554E+10 | 4220.20 | 01-NOV-07:10 | 0.950025E+10 | 6808.32 | 01-NOV-07:10 |
December | 0.390282E+10 | 4220.20 | 01-DEC-08:09 | 0.955443E+10 | 6808.32 | 01-DEC-08:09 |
Annual Sum or Average | 0.483329E+11 | 0.115425E+12 | ||||
Minimum of Months | 0.365805E+10 | 4220.20 | 0.879311E+10 | 6808.32 | ||
Maximum of Months | 0.434679E+10 | 4220.20 | 0.101015E+11 | 6808.32 |
Report: ZoneElectricSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.403280E+10 | 4220.20 | 02-JAN-08:09 | 0.971303E+10 | 6808.32 | 02-JAN-08:09 |
February | 0.365805E+10 | 4220.20 | 01-FEB-08:09 | 0.879311E+10 | 6808.32 | 01-FEB-08:09 |
March | 0.434679E+10 | 4220.20 | 01-MAR-08:09 | 0.101015E+11 | 6808.32 | 01-MAR-08:09 |
April | 0.388256E+10 | 4220.20 | 03-APR-07:10 | 0.937947E+10 | 6808.32 | 03-APR-07:10 |
May | 0.418979E+10 | 4220.20 | 01-MAY-07:10 | 0.990724E+10 | 6808.32 | 01-MAY-07:10 |
June | 0.416954E+10 | 4220.20 | 01-JUN-07:10 | 0.972788E+10 | 6808.32 | 01-JUN-07:10 |
July | 0.390282E+10 | 4220.20 | 03-JUL-07:10 | 0.955663E+10 | 6808.32 | 03-JUL-07:10 |
August | 0.434679E+10 | 4220.20 | 01-AUG-07:10 | 0.101015E+11 | 6808.32 | 01-AUG-07:10 |
September | 0.388256E+10 | 4220.20 | 01-SEP-07:10 | 0.937507E+10 | 6808.32 | 01-SEP-07:10 |
October | 0.403280E+10 | 4220.20 | 02-OCT-07:10 | 0.971523E+10 | 6808.32 | 02-OCT-07:10 |
November | 0.398554E+10 | 4220.20 | 01-NOV-07:10 | 0.950025E+10 | 6808.32 | 01-NOV-07:10 |
December | 0.390282E+10 | 4220.20 | 01-DEC-08:09 | 0.955443E+10 | 6808.32 | 01-DEC-08:09 |
Annual Sum or Average | 0.483329E+11 | 0.115425E+12 | ||||
Minimum of Months | 0.365805E+10 | 4220.20 | 0.879311E+10 | 6808.32 | ||
Maximum of Months | 0.434679E+10 | 4220.20 | 0.101015E+11 | 6808.32 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.556649E+09 | 813.93 | 20-JAN-08:09 | 0.204758E+10 | 1435.25 | 02-JAN-08:09 |
February | 0.485824E+09 | 776.68 | 03-FEB-08:09 | 0.185366E+10 | 1435.25 | 01-FEB-08:09 |
March | 0.534337E+09 | 730.10 | 21-MAR-07:10 | 0.212947E+10 | 1435.25 | 01-MAR-08:09 |
April | 0.456413E+09 | 586.82 | 04-APR-07:10 | 0.197726E+10 | 1435.25 | 03-APR-07:10 |
May | 0.478563E+09 | 474.56 | 26-MAY-08:30 | 0.208852E+10 | 1435.25 | 01-MAY-07:10 |
June | 0.465616E+09 | 424.37 | 01-JUN-07:10 | 0.205071E+10 | 1435.25 | 01-JUN-07:10 |
July | 0.444275E+09 | 484.50 | 13-JUL-15:00 | 0.201461E+10 | 1435.25 | 03-JUL-07:10 |
August | 0.510901E+09 | 734.39 | 04-AUG-07:10 | 0.212947E+10 | 1435.25 | 01-AUG-07:10 |
September | 0.468398E+09 | 663.50 | 29-SEP-07:10 | 0.197634E+10 | 1435.25 | 01-SEP-07:10 |
October | 0.526582E+09 | 792.36 | 31-OCT-07:10 | 0.204804E+10 | 1435.25 | 02-OCT-07:10 |
November | 0.539637E+09 | 889.66 | 28-NOV-16:30 | 0.200273E+10 | 1435.25 | 01-NOV-07:10 |
December | 0.551408E+09 | 889.66 | 01-DEC-16:30 | 0.201415E+10 | 1435.25 | 01-DEC-08:09 |
Annual Sum or Average | 0.601860E+10 | 0.243325E+11 | ||||
Minimum of Months | 0.444275E+09 | 424.37 | 0.185366E+10 | 1435.25 | ||
Maximum of Months | 0.556649E+09 | 889.66 | 0.212947E+10 | 1435.25 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.331773E+09 | 509.99 | 20-JAN-16:00 | 0.129621E+10 | 908.57 | 02-JAN-08:09 |
February | 0.296624E+09 | 471.70 | 10-FEB-08:09 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.332420E+09 | 396.41 | 09-MAR-16:00 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.286479E+09 | 268.66 | 03-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.304983E+09 | 293.79 | 25-MAY-15:30 | 0.132213E+10 | 908.57 | 01-MAY-07:10 |
June | 0.297920E+09 | 268.66 | 01-JUN-07:10 | 0.129819E+10 | 908.57 | 01-JUN-07:10 |
July | 0.284384E+09 | 310.28 | 13-JUL-15:00 | 0.127534E+10 | 908.57 | 03-JUL-07:10 |
August | 0.322056E+09 | 454.03 | 04-AUG-07:10 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.293934E+09 | 309.36 | 29-SEP-14:30 | 0.125111E+10 | 908.57 | 01-SEP-07:10 |
October | 0.318051E+09 | 410.97 | 31-OCT-15:00 | 0.129650E+10 | 908.57 | 02-OCT-07:10 |
November | 0.327598E+09 | 563.23 | 28-NOV-16:30 | 0.126781E+10 | 908.57 | 01-NOV-07:10 |
December | 0.329727E+09 | 563.23 | 01-DEC-16:30 | 0.127504E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.372595E+10 | 0.154036E+11 | ||||
Minimum of Months | 0.284384E+09 | 268.66 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.332420E+09 | 563.23 | 0.134804E+10 | 908.57 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.507797E+09 | 796.24 | 20-JAN-16:00 | 0.204757E+10 | 1435.24 | 02-JAN-08:09 |
February | 0.458294E+09 | 756.28 | 10-FEB-08:09 | 0.185364E+10 | 1435.24 | 01-FEB-08:09 |
March | 0.520140E+09 | 706.07 | 21-MAR-07:10 | 0.212945E+10 | 1435.24 | 01-MAR-08:09 |
April | 0.457992E+09 | 605.40 | 04-APR-07:10 | 0.197725E+10 | 1435.24 | 03-APR-07:10 |
May | 0.486822E+09 | 474.57 | 26-MAY-08:30 | 0.208851E+10 | 1435.24 | 01-MAY-07:10 |
June | 0.476675E+09 | 471.17 | 27-JUN-07:10 | 0.205070E+10 | 1435.24 | 01-JUN-07:10 |
July | 0.454535E+09 | 591.77 | 27-JUL-07:10 | 0.201460E+10 | 1435.24 | 03-JUL-07:10 |
August | 0.514073E+09 | 737.51 | 04-AUG-07:10 | 0.212945E+10 | 1435.24 | 01-AUG-07:10 |
September | 0.463829E+09 | 584.43 | 18-SEP-07:10 | 0.197632E+10 | 1435.24 | 01-SEP-07:10 |
October | 0.488326E+09 | 685.78 | 27-OCT-07:10 | 0.204803E+10 | 1435.24 | 02-OCT-07:10 |
November | 0.500877E+09 | 889.66 | 28-NOV-16:30 | 0.200271E+10 | 1435.24 | 01-NOV-07:10 |
December | 0.501918E+09 | 889.66 | 01-DEC-16:30 | 0.201413E+10 | 1435.24 | 01-DEC-08:09 |
Annual Sum or Average | 0.583128E+10 | 0.243324E+11 | ||||
Minimum of Months | 0.454535E+09 | 471.17 | 0.185364E+10 | 1435.24 | ||
Maximum of Months | 0.520140E+09 | 889.66 | 0.212945E+10 | 1435.24 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.339834E+09 | 520.44 | 20-JAN-08:09 | 0.129620E+10 | 908.57 | 02-JAN-08:09 |
February | 0.301122E+09 | 492.41 | 03-FEB-08:09 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.336216E+09 | 492.78 | 21-MAR-07:10 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.291209E+09 | 417.37 | 04-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.307782E+09 | 349.68 | 05-MAY-07:10 | 0.132212E+10 | 908.57 | 01-MAY-07:10 |
June | 0.300302E+09 | 339.62 | 27-JUN-07:10 | 0.129818E+10 | 908.57 | 01-JUN-07:10 |
July | 0.287034E+09 | 388.97 | 27-JUL-07:10 | 0.127533E+10 | 908.57 | 03-JUL-07:10 |
August | 0.326484E+09 | 471.18 | 04-AUG-07:10 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.297375E+09 | 450.36 | 29-SEP-07:10 | 0.125110E+10 | 908.57 | 01-SEP-07:10 |
October | 0.324755E+09 | 506.11 | 27-OCT-07:10 | 0.129649E+10 | 908.57 | 02-OCT-07:10 |
November | 0.329511E+09 | 563.19 | 28-NOV-16:30 | 0.126780E+10 | 908.57 | 01-NOV-07:10 |
December | 0.334064E+09 | 563.19 | 01-DEC-16:30 | 0.127503E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.377569E+10 | 0.154035E+11 | ||||
Minimum of Months | 0.287034E+09 | 339.62 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.339834E+09 | 563.19 | 0.134804E+10 | 908.57 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.551741E+09 | 810.13 | 20-JAN-08:09 | 0.204758E+10 | 1435.25 | 02-JAN-08:09 |
February | 0.483003E+09 | 771.80 | 03-FEB-08:09 | 0.185366E+10 | 1435.25 | 01-FEB-08:09 |
March | 0.531867E+09 | 722.38 | 21-MAR-07:10 | 0.212947E+10 | 1435.25 | 01-MAR-08:09 |
April | 0.455508E+09 | 571.10 | 04-APR-07:10 | 0.197726E+10 | 1435.25 | 03-APR-07:10 |
May | 0.478151E+09 | 470.75 | 26-MAY-08:30 | 0.208852E+10 | 1435.25 | 01-MAY-07:10 |
June | 0.465491E+09 | 424.37 | 01-JUN-07:10 | 0.205071E+10 | 1435.25 | 01-JUN-07:10 |
July | 0.443665E+09 | 481.20 | 13-JUL-15:00 | 0.201461E+10 | 1435.25 | 03-JUL-07:10 |
August | 0.509359E+09 | 727.43 | 04-AUG-07:10 | 0.212947E+10 | 1435.25 | 01-AUG-07:10 |
September | 0.466898E+09 | 652.87 | 29-SEP-07:10 | 0.197634E+10 | 1435.25 | 01-SEP-07:10 |
October | 0.522835E+09 | 786.34 | 31-OCT-07:10 | 0.204804E+10 | 1435.25 | 02-OCT-07:10 |
November | 0.535179E+09 | 889.66 | 28-NOV-16:30 | 0.200273E+10 | 1435.25 | 01-NOV-07:10 |
December | 0.546651E+09 | 889.66 | 01-DEC-16:30 | 0.201415E+10 | 1435.25 | 01-DEC-08:09 |
Annual Sum or Average | 0.599035E+10 | 0.243325E+11 | ||||
Minimum of Months | 0.443665E+09 | 424.37 | 0.185366E+10 | 1435.25 | ||
Maximum of Months | 0.551741E+09 | 889.66 | 0.212947E+10 | 1435.25 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.330344E+09 | 508.08 | 20-JAN-16:00 | 0.129621E+10 | 908.57 | 02-JAN-08:09 |
February | 0.295691E+09 | 468.19 | 10-FEB-08:09 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.331678E+09 | 390.84 | 09-MAR-16:00 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.286047E+09 | 268.66 | 03-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.304696E+09 | 291.36 | 25-MAY-15:30 | 0.132213E+10 | 908.57 | 01-MAY-07:10 |
June | 0.297580E+09 | 268.66 | 01-JUN-07:10 | 0.129819E+10 | 908.57 | 01-JUN-07:10 |
July | 0.283864E+09 | 308.57 | 13-JUL-15:00 | 0.127534E+10 | 908.57 | 03-JUL-07:10 |
August | 0.321389E+09 | 449.89 | 04-AUG-07:10 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.293330E+09 | 307.89 | 29-SEP-14:30 | 0.125111E+10 | 908.57 | 01-SEP-07:10 |
October | 0.317000E+09 | 406.74 | 31-OCT-15:00 | 0.129650E+10 | 908.57 | 02-OCT-07:10 |
November | 0.326246E+09 | 563.23 | 28-NOV-16:30 | 0.126781E+10 | 908.57 | 01-NOV-07:10 |
December | 0.328472E+09 | 563.23 | 01-DEC-16:30 | 0.127504E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.371634E+10 | 0.154036E+11 | ||||
Minimum of Months | 0.283864E+09 | 268.66 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.331678E+09 | 563.23 | 0.134804E+10 | 908.57 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.505306E+09 | 791.96 | 20-JAN-16:00 | 0.204757E+10 | 1435.24 | 02-JAN-08:09 |
February | 0.457566E+09 | 750.19 | 10-FEB-08:09 | 0.185364E+10 | 1435.24 | 01-FEB-08:09 |
March | 0.519235E+09 | 697.25 | 21-MAR-07:10 | 0.212945E+10 | 1435.24 | 01-MAR-08:09 |
April | 0.457078E+09 | 590.99 | 04-APR-07:10 | 0.197725E+10 | 1435.24 | 03-APR-07:10 |
May | 0.485919E+09 | 470.75 | 26-MAY-08:30 | 0.208851E+10 | 1435.24 | 01-MAY-07:10 |
June | 0.475419E+09 | 468.59 | 27-JUN-07:10 | 0.205070E+10 | 1435.24 | 01-JUN-07:10 |
July | 0.453079E+09 | 579.17 | 27-JUL-07:10 | 0.201460E+10 | 1435.24 | 03-JUL-07:10 |
August | 0.512508E+09 | 730.72 | 04-AUG-07:10 | 0.212945E+10 | 1435.24 | 01-AUG-07:10 |
September | 0.463011E+09 | 568.24 | 18-SEP-07:10 | 0.197632E+10 | 1435.24 | 01-SEP-07:10 |
October | 0.487777E+09 | 676.20 | 27-OCT-07:10 | 0.204803E+10 | 1435.24 | 02-OCT-07:10 |
November | 0.500040E+09 | 889.66 | 28-NOV-16:30 | 0.200271E+10 | 1435.24 | 01-NOV-07:10 |
December | 0.500414E+09 | 889.66 | 01-DEC-16:30 | 0.201413E+10 | 1435.24 | 01-DEC-08:09 |
Annual Sum or Average | 0.581735E+10 | 0.243324E+11 | ||||
Minimum of Months | 0.453079E+09 | 468.59 | 0.185364E+10 | 1435.24 | ||
Maximum of Months | 0.519235E+09 | 889.66 | 0.212945E+10 | 1435.24 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.338442E+09 | 518.69 | 20-JAN-08:09 | 0.129620E+10 | 908.57 | 02-JAN-08:09 |
February | 0.300054E+09 | 489.90 | 03-FEB-08:09 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.335114E+09 | 490.26 | 21-MAR-07:10 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.290369E+09 | 411.05 | 04-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.307201E+09 | 341.65 | 05-MAY-07:10 | 0.132212E+10 | 908.57 | 01-MAY-07:10 |
June | 0.299686E+09 | 331.76 | 27-JUN-07:10 | 0.129818E+10 | 908.57 | 01-JUN-07:10 |
July | 0.286211E+09 | 382.93 | 27-JUL-07:10 | 0.127533E+10 | 908.57 | 03-JUL-07:10 |
August | 0.325263E+09 | 467.91 | 04-AUG-07:10 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.296401E+09 | 446.33 | 29-SEP-07:10 | 0.125110E+10 | 908.57 | 01-SEP-07:10 |
October | 0.323577E+09 | 503.61 | 27-OCT-07:10 | 0.129649E+10 | 908.57 | 02-OCT-07:10 |
November | 0.328403E+09 | 563.19 | 28-NOV-16:30 | 0.126780E+10 | 908.57 | 01-NOV-07:10 |
December | 0.332889E+09 | 563.19 | 01-DEC-16:30 | 0.127503E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.376361E+10 | 0.154035E+11 | ||||
Minimum of Months | 0.286211E+09 | 331.76 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.338442E+09 | 563.19 | 0.134804E+10 | 908.57 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.556649E+09 | 813.93 | 20-JAN-08:09 | 0.204758E+10 | 1435.25 | 02-JAN-08:09 |
February | 0.485823E+09 | 776.68 | 03-FEB-08:09 | 0.185366E+10 | 1435.25 | 01-FEB-08:09 |
March | 0.534336E+09 | 730.09 | 21-MAR-07:10 | 0.212947E+10 | 1435.25 | 01-MAR-08:09 |
April | 0.456413E+09 | 586.82 | 04-APR-07:10 | 0.197726E+10 | 1435.25 | 03-APR-07:10 |
May | 0.478563E+09 | 474.56 | 26-MAY-08:30 | 0.208852E+10 | 1435.25 | 01-MAY-07:10 |
June | 0.465616E+09 | 424.37 | 01-JUN-07:10 | 0.205071E+10 | 1435.25 | 01-JUN-07:10 |
July | 0.444275E+09 | 484.50 | 13-JUL-15:00 | 0.201461E+10 | 1435.25 | 03-JUL-07:10 |
August | 0.510900E+09 | 734.38 | 04-AUG-07:10 | 0.212947E+10 | 1435.25 | 01-AUG-07:10 |
September | 0.468397E+09 | 663.49 | 29-SEP-07:10 | 0.197634E+10 | 1435.25 | 01-SEP-07:10 |
October | 0.526581E+09 | 792.36 | 31-OCT-07:10 | 0.204804E+10 | 1435.25 | 02-OCT-07:10 |
November | 0.539636E+09 | 889.66 | 28-NOV-16:30 | 0.200273E+10 | 1435.25 | 01-NOV-07:10 |
December | 0.551408E+09 | 889.66 | 01-DEC-16:30 | 0.201415E+10 | 1435.25 | 01-DEC-08:09 |
Annual Sum or Average | 0.601860E+10 | 0.243325E+11 | ||||
Minimum of Months | 0.444275E+09 | 424.37 | 0.185366E+10 | 1435.25 | ||
Maximum of Months | 0.556649E+09 | 889.66 | 0.212947E+10 | 1435.25 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.331773E+09 | 509.98 | 20-JAN-16:00 | 0.129621E+10 | 908.57 | 02-JAN-08:09 |
February | 0.296623E+09 | 471.69 | 10-FEB-08:09 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.332420E+09 | 396.42 | 09-MAR-16:00 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.286479E+09 | 268.66 | 03-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.304983E+09 | 293.78 | 25-MAY-15:30 | 0.132213E+10 | 908.57 | 01-MAY-07:10 |
June | 0.297920E+09 | 268.66 | 01-JUN-07:10 | 0.129819E+10 | 908.57 | 01-JUN-07:10 |
July | 0.284383E+09 | 310.28 | 13-JUL-15:00 | 0.127534E+10 | 908.57 | 03-JUL-07:10 |
August | 0.322056E+09 | 454.03 | 04-AUG-07:10 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.293934E+09 | 309.36 | 29-SEP-14:30 | 0.125111E+10 | 908.57 | 01-SEP-07:10 |
October | 0.318051E+09 | 410.97 | 31-OCT-15:00 | 0.129650E+10 | 908.57 | 02-OCT-07:10 |
November | 0.327598E+09 | 563.23 | 28-NOV-16:30 | 0.126781E+10 | 908.57 | 01-NOV-07:10 |
December | 0.329727E+09 | 563.23 | 01-DEC-16:30 | 0.127504E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.372595E+10 | 0.154036E+11 | ||||
Minimum of Months | 0.284383E+09 | 268.66 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.332420E+09 | 563.23 | 0.134804E+10 | 908.57 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.507797E+09 | 796.24 | 20-JAN-16:00 | 0.204757E+10 | 1435.24 | 02-JAN-08:09 |
February | 0.458293E+09 | 756.27 | 10-FEB-08:09 | 0.185364E+10 | 1435.24 | 01-FEB-08:09 |
March | 0.520139E+09 | 706.06 | 21-MAR-07:10 | 0.212945E+10 | 1435.24 | 01-MAR-08:09 |
April | 0.457992E+09 | 605.41 | 04-APR-07:10 | 0.197725E+10 | 1435.24 | 03-APR-07:10 |
May | 0.486822E+09 | 474.56 | 26-MAY-08:30 | 0.208851E+10 | 1435.24 | 01-MAY-07:10 |
June | 0.476675E+09 | 471.16 | 27-JUN-07:10 | 0.205070E+10 | 1435.24 | 01-JUN-07:10 |
July | 0.454524E+09 | 591.78 | 27-JUL-07:10 | 0.201460E+10 | 1435.24 | 03-JUL-07:10 |
August | 0.514072E+09 | 737.50 | 04-AUG-07:10 | 0.212945E+10 | 1435.24 | 01-AUG-07:10 |
September | 0.463828E+09 | 584.43 | 18-SEP-07:10 | 0.197632E+10 | 1435.24 | 01-SEP-07:10 |
October | 0.488326E+09 | 685.78 | 27-OCT-07:10 | 0.204803E+10 | 1435.24 | 02-OCT-07:10 |
November | 0.500877E+09 | 889.66 | 28-NOV-16:30 | 0.200271E+10 | 1435.24 | 01-NOV-07:10 |
December | 0.501918E+09 | 889.66 | 01-DEC-16:30 | 0.201413E+10 | 1435.24 | 01-DEC-08:09 |
Annual Sum or Average | 0.583126E+10 | 0.243324E+11 | ||||
Minimum of Months | 0.454524E+09 | 471.16 | 0.185364E+10 | 1435.24 | ||
Maximum of Months | 0.520139E+09 | 889.66 | 0.212945E+10 | 1435.24 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.339835E+09 | 520.43 | 20-JAN-08:09 | 0.129620E+10 | 908.57 | 02-JAN-08:09 |
February | 0.301121E+09 | 492.41 | 03-FEB-08:09 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.336215E+09 | 492.77 | 21-MAR-07:10 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.291209E+09 | 417.38 | 04-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.307782E+09 | 349.69 | 05-MAY-07:10 | 0.132212E+10 | 908.57 | 01-MAY-07:10 |
June | 0.300302E+09 | 339.62 | 27-JUN-07:10 | 0.129818E+10 | 908.57 | 01-JUN-07:10 |
July | 0.287033E+09 | 388.97 | 27-JUL-07:10 | 0.127533E+10 | 908.57 | 03-JUL-07:10 |
August | 0.326483E+09 | 471.17 | 04-AUG-07:10 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.297375E+09 | 450.35 | 29-SEP-07:10 | 0.125110E+10 | 908.57 | 01-SEP-07:10 |
October | 0.324755E+09 | 506.11 | 27-OCT-07:10 | 0.129649E+10 | 908.57 | 02-OCT-07:10 |
November | 0.329511E+09 | 563.19 | 28-NOV-16:30 | 0.126780E+10 | 908.57 | 01-NOV-07:10 |
December | 0.334065E+09 | 563.19 | 01-DEC-16:30 | 0.127503E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.377569E+10 | 0.154035E+11 | ||||
Minimum of Months | 0.287033E+09 | 339.62 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.339835E+09 | 563.19 | 0.134804E+10 | 908.57 |
Report: SpaceGainsMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.471610E+10 | 0.403280E+10 | 0.198672E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.427861E+10 | 0.365805E+10 | 0.179823E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.511242E+10 | 0.434679E+10 | 0.207117E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.453654E+10 | 0.388256E+10 | 0.191625E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.491426E+10 | 0.418979E+10 | 0.202894E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.490054E+10 | 0.416954E+10 | 0.199404E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.455026E+10 | 0.390282E+10 | 0.195094E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.511242E+10 | 0.434679E+10 | 0.207117E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.453654E+10 | 0.388256E+10 | 0.191582E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.471610E+10 | 0.403280E+10 | 0.198694E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.467005E+10 | 0.398554E+10 | 0.194582E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.455026E+10 | 0.390282E+10 | 0.195072E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.565941E+11 | 0.483329E+11 | 0.236167E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.427861E+10 | 0.365805E+10 | 0.179823E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.511242E+10 | 0.434679E+10 | 0.207117E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.471610E+10 | 0.403280E+10 | 0.971303E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.427861E+10 | 0.365805E+10 | 0.879311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.511242E+10 | 0.434679E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.453654E+10 | 0.388256E+10 | 0.937947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.491426E+10 | 0.418979E+10 | 0.990724E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.490054E+10 | 0.416954E+10 | 0.972788E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.455026E+10 | 0.390282E+10 | 0.955663E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.511242E+10 | 0.434679E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.453654E+10 | 0.388256E+10 | 0.937507E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.471610E+10 | 0.403280E+10 | 0.971523E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.467005E+10 | 0.398554E+10 | 0.950025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.455026E+10 | 0.390282E+10 | 0.955443E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.565941E+11 | 0.483329E+11 | 0.115425E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.427861E+10 | 0.365805E+10 | 0.879311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.511242E+10 | 0.434679E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.471610E+10 | 0.403280E+10 | 0.971303E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.427861E+10 | 0.365805E+10 | 0.879311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.511242E+10 | 0.434679E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.453654E+10 | 0.388256E+10 | 0.937947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.491426E+10 | 0.418979E+10 | 0.990724E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.490054E+10 | 0.416954E+10 | 0.972788E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.455026E+10 | 0.390282E+10 | 0.955663E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.511242E+10 | 0.434679E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.453654E+10 | 0.388256E+10 | 0.937507E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.471610E+10 | 0.403280E+10 | 0.971523E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.467005E+10 | 0.398554E+10 | 0.950025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.455026E+10 | 0.390282E+10 | 0.955443E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.565941E+11 | 0.483329E+11 | 0.115425E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.427861E+10 | 0.365805E+10 | 0.879311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.511242E+10 | 0.434679E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.556649E+09 | 0.204758E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 892481.95 | 87815974.07 |
February | 0.901968E+09 | 0.485824E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 69681884.67 |
March | 0.107774E+10 | 0.534337E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 938995.62 | 93614978.33 |
April | 0.956342E+09 | 0.456413E+09 | 0.197726E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17188524.26 | 32336116.61 |
May | 0.103597E+10 | 0.478563E+09 | 0.208852E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31881007.11 | 20776628.01 |
June | 0.103308E+10 | 0.465616E+09 | 0.205071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57167462.14 | 6291541.46 |
July | 0.959235E+09 | 0.444275E+09 | 0.201461E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 56190372.21 | 5468173.07 |
August | 0.107774E+10 | 0.510901E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 39473814.24 | 7499411.21 |
September | 0.956342E+09 | 0.468398E+09 | 0.197634E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 29456096.93 | 14171702.81 |
October | 0.994195E+09 | 0.526582E+09 | 0.204804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11507526.80 | 48091764.75 |
November | 0.984487E+09 | 0.539637E+09 | 0.200273E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1600098.31 | 80199359.88 |
December | 0.959235E+09 | 0.551408E+09 | 0.201415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 435058.66 | 83181234.96 |
Annual Sum or Average | 0.119305E+11 | 0.601860E+10 | 0.243325E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.246731E+09 | 0.549129E+09 |
Minimum of Months | 0.901968E+09 | 0.444275E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5468173.07 |
Maximum of Months | 0.107774E+10 | 0.556649E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57167462.14 | 93614978.33 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629407E+09 | 0.331773E+09 | 0.129621E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 345821.80 | 61244811.75 |
February | 0.571020E+09 | 0.296624E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 48189396.24 |
March | 0.682301E+09 | 0.332420E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 596361.37 | 64724824.25 |
April | 0.605444E+09 | 0.286479E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10893770.64 | 22884993.20 |
May | 0.655854E+09 | 0.304983E+09 | 0.132213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20782958.44 | 14406906.99 |
June | 0.654023E+09 | 0.297920E+09 | 0.129819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38297862.04 | 4254870.14 |
July | 0.607275E+09 | 0.284384E+09 | 0.127534E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37614768.97 | 3752151.22 |
August | 0.682301E+09 | 0.322056E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25958945.83 | 5270552.47 |
September | 0.605444E+09 | 0.293934E+09 | 0.125111E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19434417.13 | 9704697.29 |
October | 0.629407E+09 | 0.318051E+09 | 0.129650E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7142447.18 | 33502598.08 |
November | 0.623262E+09 | 0.327598E+09 | 0.126781E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 751876.60 | 55503611.43 |
December | 0.607275E+09 | 0.329727E+09 | 0.127504E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 169977.79 | 57209839.74 |
Annual Sum or Average | 0.755301E+10 | 0.372595E+10 | 0.154036E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.161989E+09 | 0.380649E+09 |
Minimum of Months | 0.571020E+09 | 0.284384E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3752151.22 |
Maximum of Months | 0.682301E+09 | 0.332420E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38297862.04 | 64724824.25 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.507797E+09 | 0.204757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 294653.52 | 0.101381E+09 |
February | 0.901968E+09 | 0.458294E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 76000291.05 |
March | 0.107774E+10 | 0.520140E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 821964.11 | 99611902.72 |
April | 0.956342E+09 | 0.457992E+09 | 0.197725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15766636.04 | 33513994.64 |
May | 0.103597E+10 | 0.486822E+09 | 0.208851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31719888.69 | 20679222.28 |
June | 0.103308E+10 | 0.476675E+09 | 0.205070E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57974852.03 | 6086832.38 |
July | 0.959235E+09 | 0.454535E+09 | 0.201460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 56564390.97 | 5350447.42 |
August | 0.107774E+10 | 0.514073E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 39036022.81 | 7721765.29 |
September | 0.956342E+09 | 0.463829E+09 | 0.197632E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 28408997.98 | 14998164.60 |
October | 0.994195E+09 | 0.488326E+09 | 0.204803E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9761721.35 | 53279737.09 |
November | 0.984487E+09 | 0.500877E+09 | 0.200271E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 540721.95 | 90028870.68 |
December | 0.959235E+09 | 0.501918E+09 | 0.201413E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 26594.94 | 93839914.86 |
Annual Sum or Average | 0.119305E+11 | 0.583128E+10 | 0.243324E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.240916E+09 | 0.602492E+09 |
Minimum of Months | 0.901968E+09 | 0.454535E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5350447.42 |
Maximum of Months | 0.107774E+10 | 0.520140E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57974852.03 | 0.101381E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629366E+09 | 0.339834E+09 | 0.129620E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 400045.27 | 61375800.62 |
February | 0.570983E+09 | 0.301122E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47748789.71 |
March | 0.682256E+09 | 0.336216E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 605158.94 | 64408724.84 |
April | 0.605404E+09 | 0.291209E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10425255.02 | 22980871.83 |
May | 0.655811E+09 | 0.307782E+09 | 0.132212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20685182.65 | 14582191.99 |
June | 0.653980E+09 | 0.300302E+09 | 0.129818E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37869393.59 | 4389558.02 |
July | 0.607235E+09 | 0.287034E+09 | 0.127533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37157399.57 | 3836707.59 |
August | 0.682256E+09 | 0.326484E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25891754.08 | 5257129.06 |
September | 0.605404E+09 | 0.297375E+09 | 0.125110E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19403015.89 | 9785495.89 |
October | 0.629366E+09 | 0.324755E+09 | 0.129649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7239415.07 | 33464827.59 |
November | 0.623221E+09 | 0.329511E+09 | 0.126780E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 829794.62 | 55618042.10 |
December | 0.607235E+09 | 0.334064E+09 | 0.127503E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 140526.43 | 57307484.42 |
Annual Sum or Average | 0.755252E+10 | 0.377569E+10 | 0.154035E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160647E+09 | 0.380756E+09 |
Minimum of Months | 0.570983E+09 | 0.287034E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3836707.59 |
Maximum of Months | 0.682256E+09 | 0.339834E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37869393.59 | 64408724.84 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.551741E+09 | 0.204758E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 475770.96 | 51084384.85 |
February | 0.901968E+09 | 0.483003E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39508130.02 |
March | 0.107774E+10 | 0.531867E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 568798.85 | 50670963.93 |
April | 0.956342E+09 | 0.455508E+09 | 0.197726E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10399721.48 | 16782715.24 |
May | 0.103597E+10 | 0.478151E+09 | 0.208852E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18751746.34 | 10307344.86 |
June | 0.103308E+10 | 0.465491E+09 | 0.205071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31784201.54 | 2931317.06 |
July | 0.959235E+09 | 0.443665E+09 | 0.201461E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31175182.84 | 2808523.75 |
August | 0.107774E+10 | 0.509359E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21692130.78 | 4196435.58 |
September | 0.956342E+09 | 0.466898E+09 | 0.197634E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16030420.51 | 8106654.50 |
October | 0.994195E+09 | 0.522835E+09 | 0.204804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6216772.54 | 28892240.42 |
November | 0.984487E+09 | 0.535179E+09 | 0.200273E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 722138.63 | 49394736.80 |
December | 0.959235E+09 | 0.546651E+09 | 0.201415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 163952.68 | 50807580.38 |
Annual Sum or Average | 0.119305E+11 | 0.599035E+10 | 0.243325E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.137981E+09 | 0.315491E+09 |
Minimum of Months | 0.901968E+09 | 0.443665E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2808523.75 |
Maximum of Months | 0.107774E+10 | 0.551741E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31784201.54 | 51084384.85 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629407E+09 | 0.330344E+09 | 0.129621E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 151184.04 | 36554641.61 |
February | 0.571020E+09 | 0.295691E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27888331.47 |
March | 0.682301E+09 | 0.331678E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 324095.91 | 36163454.07 |
April | 0.605444E+09 | 0.286047E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6124187.09 | 12514491.63 |
May | 0.655854E+09 | 0.304696E+09 | 0.132213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11498104.26 | 7626279.61 |
June | 0.654023E+09 | 0.297580E+09 | 0.129819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20684870.89 | 2183932.76 |
July | 0.607275E+09 | 0.283864E+09 | 0.127534E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20207409.20 | 2129799.87 |
August | 0.682301E+09 | 0.321389E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13854371.18 | 3186700.07 |
September | 0.605444E+09 | 0.293330E+09 | 0.125111E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10294643.63 | 5879806.81 |
October | 0.629407E+09 | 0.317000E+09 | 0.129650E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3771200.10 | 20473915.54 |
November | 0.623262E+09 | 0.326246E+09 | 0.126781E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 328383.53 | 34634645.34 |
December | 0.607275E+09 | 0.328472E+09 | 0.127504E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 53155.58 | 35647546.61 |
Annual Sum or Average | 0.755301E+10 | 0.371634E+10 | 0.154036E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 87291605.41 | 0.224884E+09 |
Minimum of Months | 0.571020E+09 | 0.283864E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2129799.87 |
Maximum of Months | 0.682301E+09 | 0.331678E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20684870.89 | 36554641.61 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.505306E+09 | 0.204757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 44089815.96 | 0.218632E+10 |
February | 0.901968E+09 | 0.457566E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.271657E+10 |
March | 0.107774E+10 | 0.519235E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.148681E+09 | 0.220816E+10 |
April | 0.956342E+09 | 0.457078E+09 | 0.197725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.113121E+10 | 0.668037E+09 |
May | 0.103597E+10 | 0.485919E+09 | 0.208851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.197099E+10 | 0.285636E+09 |
June | 0.103308E+10 | 0.475419E+09 | 0.205070E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.313916E+10 | 52579385.98 |
July | 0.959235E+09 | 0.453079E+09 | 0.201460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.252529E+10 | 17896645.98 |
August | 0.107774E+10 | 0.512508E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.271699E+10 | 74995718.16 |
September | 0.956342E+09 | 0.463011E+09 | 0.197632E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.182482E+10 | 0.190350E+09 |
October | 0.994195E+09 | 0.487777E+09 | 0.204803E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.796776E+09 | 0.127824E+10 |
November | 0.984487E+09 | 0.500040E+09 | 0.200271E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 91262367.35 | 0.203516E+10 |
December | 0.959235E+09 | 0.500414E+09 | 0.201413E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4562503.49 | 0.312366E+10 |
Annual Sum or Average | 0.119305E+11 | 0.581735E+10 | 0.243324E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.143938E+11 | 0.148376E+11 |
Minimum of Months | 0.901968E+09 | 0.453079E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17896645.98 |
Maximum of Months | 0.107774E+10 | 0.519235E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.313916E+10 | 0.312366E+10 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629366E+09 | 0.338442E+09 | 0.129620E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 157142.80 | 36742342.03 |
February | 0.570983E+09 | 0.300054E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27547005.14 |
March | 0.682256E+09 | 0.335114E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 311491.50 | 35898361.60 |
April | 0.605404E+09 | 0.290369E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5676184.44 | 12753611.62 |
May | 0.655811E+09 | 0.307201E+09 | 0.132212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11202284.79 | 7867751.03 |
June | 0.653980E+09 | 0.299686E+09 | 0.129818E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20324178.27 | 2308679.14 |
July | 0.607235E+09 | 0.286211E+09 | 0.127533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19869526.10 | 2171932.08 |
August | 0.682256E+09 | 0.325263E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13739312.83 | 3153246.92 |
September | 0.605404E+09 | 0.296401E+09 | 0.125110E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10182856.24 | 5943509.80 |
October | 0.629366E+09 | 0.323577E+09 | 0.129649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3751707.73 | 20644986.10 |
November | 0.623221E+09 | 0.328403E+09 | 0.126780E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 327649.24 | 34916177.61 |
December | 0.607235E+09 | 0.332889E+09 | 0.127503E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 35800.99 | 35482301.78 |
Annual Sum or Average | 0.755252E+10 | 0.376361E+10 | 0.154035E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 85578134.93 | 0.225430E+09 |
Minimum of Months | 0.570983E+09 | 0.286211E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2171932.08 |
Maximum of Months | 0.682256E+09 | 0.338442E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20324178.27 | 36742342.03 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.556649E+09 | 0.204758E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 596405.36 | 80741394.54 |
February | 0.901968E+09 | 0.485823E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63446115.24 |
March | 0.107774E+10 | 0.534336E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 783917.53 | 83798003.72 |
April | 0.956342E+09 | 0.456413E+09 | 0.197726E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14879897.83 | 28397068.18 |
May | 0.103597E+10 | 0.478563E+09 | 0.208852E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27367662.70 | 18086104.92 |
June | 0.103308E+10 | 0.465616E+09 | 0.205071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48057552.33 | 5301587.98 |
July | 0.959235E+09 | 0.444275E+09 | 0.201461E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 47596716.68 | 4660501.87 |
August | 0.107774E+10 | 0.510900E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 33391207.98 | 6532268.99 |
September | 0.956342E+09 | 0.468397E+09 | 0.197634E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24803466.97 | 12291126.67 |
October | 0.994195E+09 | 0.526581E+09 | 0.204804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9657444.72 | 43451106.68 |
November | 0.984487E+09 | 0.539636E+09 | 0.200273E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1186232.01 | 73836621.24 |
December | 0.959235E+09 | 0.551408E+09 | 0.201415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 268365.35 | 76672869.12 |
Annual Sum or Average | 0.119305E+11 | 0.601860E+10 | 0.243325E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.208589E+09 | 0.497215E+09 |
Minimum of Months | 0.901968E+09 | 0.444275E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4660501.87 |
Maximum of Months | 0.107774E+10 | 0.556649E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48057552.33 | 83798003.72 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.465148E+09 | 0.331773E+09 | 0.129621E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 251591.76 | 55702292.29 |
February | 0.421807E+09 | 0.296623E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43398431.58 |
March | 0.502994E+09 | 0.332420E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 501895.09 | 57414624.16 |
April | 0.447140E+09 | 0.286479E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9395483.35 | 19873581.38 |
May | 0.484071E+09 | 0.304983E+09 | 0.132213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17736915.07 | 12460081.48 |
June | 0.482240E+09 | 0.297920E+09 | 0.129819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 32201635.46 | 3566355.57 |
July | 0.448971E+09 | 0.284383E+09 | 0.127534E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31811758.97 | 3192893.01 |
August | 0.502994E+09 | 0.322056E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21938386.90 | 4559264.24 |
September | 0.447140E+09 | 0.293934E+09 | 0.125111E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16316998.21 | 8380665.75 |
October | 0.465148E+09 | 0.318051E+09 | 0.129650E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6029009.08 | 29866871.35 |
November | 0.460569E+09 | 0.327598E+09 | 0.126781E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 586836.47 | 50603360.62 |
December | 0.448971E+09 | 0.329727E+09 | 0.127504E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 112458.43 | 52407465.30 |
Annual Sum or Average | 0.557719E+10 | 0.372595E+10 | 0.154036E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.136883E+09 | 0.341426E+09 |
Minimum of Months | 0.421807E+09 | 0.284383E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3192893.01 |
Maximum of Months | 0.502994E+09 | 0.332420E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 32201635.46 | 57414624.16 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.507797E+09 | 0.204757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 243608.46 | 91271825.46 |
February | 0.901968E+09 | 0.458293E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 68335575.70 |
March | 0.107774E+10 | 0.520139E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 696126.53 | 88472909.32 |
April | 0.956342E+09 | 0.457992E+09 | 0.197725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13373647.84 | 29438925.84 |
May | 0.103597E+10 | 0.486822E+09 | 0.208851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 26836810.93 | 18098603.00 |
June | 0.103308E+10 | 0.476675E+09 | 0.205070E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48633232.99 | 5160869.27 |
July | 0.959235E+09 | 0.454524E+09 | 0.201460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 47645953.09 | 4595345.68 |
August | 0.107774E+10 | 0.514072E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 32807092.48 | 6739109.98 |
September | 0.956342E+09 | 0.463828E+09 | 0.197632E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23741150.47 | 13022135.50 |
October | 0.994195E+09 | 0.488326E+09 | 0.204803E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8134834.17 | 47470079.81 |
November | 0.984487E+09 | 0.500877E+09 | 0.200271E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 444380.59 | 81361241.30 |
December | 0.959235E+09 | 0.501918E+09 | 0.201413E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 22703.29 | 85011870.55 |
Annual Sum or Average | 0.119305E+11 | 0.583126E+10 | 0.243324E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.202580E+09 | 0.538978E+09 |
Minimum of Months | 0.901968E+09 | 0.454524E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4595345.68 |
Maximum of Months | 0.107774E+10 | 0.520139E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48633232.99 | 91271825.46 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629366E+09 | 0.339835E+09 | 0.129620E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 264401.36 | 56013732.99 |
February | 0.570983E+09 | 0.301121E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43218807.74 |
March | 0.682256E+09 | 0.336215E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 477840.34 | 57523941.33 |
April | 0.605404E+09 | 0.291209E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8726839.60 | 20210935.32 |
May | 0.655811E+09 | 0.307782E+09 | 0.132212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17280043.60 | 12735214.26 |
June | 0.653980E+09 | 0.300302E+09 | 0.129818E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31572990.49 | 3710838.73 |
July | 0.607235E+09 | 0.287033E+09 | 0.127533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31113004.99 | 3288179.01 |
August | 0.682256E+09 | 0.326483E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21695627.36 | 4591833.48 |
September | 0.605404E+09 | 0.297375E+09 | 0.125110E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16104528.62 | 8515955.10 |
October | 0.629366E+09 | 0.324755E+09 | 0.129649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5954313.90 | 30129989.43 |
November | 0.623221E+09 | 0.329511E+09 | 0.126780E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 597545.52 | 50890501.28 |
December | 0.607235E+09 | 0.334065E+09 | 0.127503E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 72371.43 | 52491253.12 |
Annual Sum or Average | 0.755252E+10 | 0.377569E+10 | 0.154035E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133860E+09 | 0.343321E+09 |
Minimum of Months | 0.570983E+09 | 0.287033E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3288179.01 |
Maximum of Months | 0.682256E+09 | 0.339835E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31572990.49 | 57523941.33 |
Report: SpaceGainsMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 222091.10 | 0.118720E+09 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 91240141.46 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 749129.50 | 0.118317E+09 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16799656.10 | 39349029.75 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32680222.02 | 24108986.43 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 59951040.98 | 6705940.17 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 59685676.75 | 5730401.39 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40859096.81 | 8578385.03 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29565635.54 | 16192751.59 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10219345.68 | 62817184.29 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 718440.98 | 0.108199E+09 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 77216.62 | 0.113311E+09 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.251528E+09 | 0.713270E+09 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5730401.39 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 59951040.98 | 0.118720E+09 |
Report: SpaceGainsMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 428376.72 | 0.144232E+09 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.111137E+09 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1063232.33 | 0.147459E+09 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21850175.45 | 50340387.41 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 41780623.10 | 31331144.45 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 76700763.68 | 8911598.99 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 76650577.19 | 7507335.61 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52776353.28 | 10774541.55 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38616694.61 | 20379199.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13858833.96 | 77102386.59 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1410277.26 | 0.131004E+09 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 215120.47 | 0.136240E+09 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.325351E+09 | 0.876418E+09 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7507335.61 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 76700763.68 | 0.147459E+09 |
Report: SpaceGainsMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 182048.31 | 0.135590E+09 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108953E+09 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 532383.88 | 0.144107E+09 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18103554.66 | 47256066.47 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38448498.70 | 26953285.90 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 79346270.78 | 7452610.61 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 76338763.80 | 6306131.90 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 54438032.66 | 9196435.13 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38745922.33 | 18306753.58 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12897676.57 | 72902946.18 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 656047.25 | 0.122932E+09 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46453.95 | 0.126883E+09 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.319736E+09 | 0.826840E+09 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6306131.90 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 79346270.78 | 0.144107E+09 |
Report: PeakSpaceGainsMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 6198.29 | 02-JAN-10:09 | 4220.20 | 02-JAN-08:09 | 18185.19 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 6198.29 | 01-FEB-10:09 | 4220.20 | 01-FEB-08:09 | 18185.19 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 6198.29 | 01-MAR-10:09 | 4220.20 | 01-MAR-08:09 | 18185.19 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 6198.29 | 03-APR-09:09 | 4220.20 | 03-APR-07:10 | 18185.19 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 6198.29 | 01-MAY-09:09 | 4220.20 | 01-MAY-07:10 | 18185.19 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 6198.29 | 01-JUN-09:09 | 4220.20 | 01-JUN-07:10 | 18185.19 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 6198.29 | 03-JUL-09:09 | 4220.20 | 03-JUL-07:10 | 18185.19 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 6198.29 | 01-AUG-09:09 | 4220.20 | 01-AUG-07:10 | 18185.19 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 6198.29 | 01-SEP-09:09 | 4220.20 | 01-SEP-07:10 | 18185.19 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 6198.29 | 02-OCT-09:09 | 4220.20 | 02-OCT-07:10 | 18185.19 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 6198.29 | 01-NOV-09:09 | 4220.20 | 01-NOV-07:10 | 18185.19 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6198.29 | 01-DEC-10:09 | 4220.20 | 01-DEC-08:09 | 18185.19 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 6198.29 | 4220.20 | 18185.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 6198.29 | 4220.20 | 18185.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 6198.29 | 02-JAN-10:09 | 4220.20 | 02-JAN-08:09 | 6808.32 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 6198.29 | 01-FEB-10:09 | 4220.20 | 01-FEB-08:09 | 6808.32 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 6198.29 | 01-MAR-10:09 | 4220.20 | 01-MAR-08:09 | 6808.32 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 6198.29 | 03-APR-09:09 | 4220.20 | 03-APR-07:10 | 6808.32 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 6198.29 | 01-MAY-09:09 | 4220.20 | 01-MAY-07:10 | 6808.32 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 6198.29 | 01-JUN-09:09 | 4220.20 | 01-JUN-07:10 | 6808.32 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 6198.29 | 03-JUL-09:09 | 4220.20 | 03-JUL-07:10 | 6808.32 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 6198.29 | 01-AUG-09:09 | 4220.20 | 01-AUG-07:10 | 6808.32 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 6198.29 | 01-SEP-09:09 | 4220.20 | 01-SEP-07:10 | 6808.32 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 6198.29 | 02-OCT-09:09 | 4220.20 | 02-OCT-07:10 | 6808.32 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 6198.29 | 01-NOV-09:09 | 4220.20 | 01-NOV-07:10 | 6808.32 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6198.29 | 01-DEC-10:09 | 4220.20 | 01-DEC-08:09 | 6808.32 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 6198.29 | 4220.20 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 6198.29 | 4220.20 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 6198.29 | 02-JAN-10:09 | 4220.20 | 02-JAN-08:09 | 6808.32 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 6198.29 | 01-FEB-10:09 | 4220.20 | 01-FEB-08:09 | 6808.32 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 6198.29 | 01-MAR-10:09 | 4220.20 | 01-MAR-08:09 | 6808.32 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 6198.29 | 03-APR-09:09 | 4220.20 | 03-APR-07:10 | 6808.32 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 6198.29 | 01-MAY-09:09 | 4220.20 | 01-MAY-07:10 | 6808.32 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 6198.29 | 01-JUN-09:09 | 4220.20 | 01-JUN-07:10 | 6808.32 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 6198.29 | 03-JUL-09:09 | 4220.20 | 03-JUL-07:10 | 6808.32 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 6198.29 | 01-AUG-09:09 | 4220.20 | 01-AUG-07:10 | 6808.32 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 6198.29 | 01-SEP-09:09 | 4220.20 | 01-SEP-07:10 | 6808.32 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 6198.29 | 02-OCT-09:09 | 4220.20 | 02-OCT-07:10 | 6808.32 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 6198.29 | 01-NOV-09:09 | 4220.20 | 01-NOV-07:10 | 6808.32 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6198.29 | 01-DEC-10:09 | 4220.20 | 01-DEC-08:09 | 6808.32 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 6198.29 | 4220.20 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 6198.29 | 4220.20 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 813.93 | 20-JAN-08:09 | 1435.25 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 25.40 | 16-JAN-12:00 | 169.14 | 01-JAN-01:00 |
February | 1306.65 | 01-FEB-10:09 | 776.68 | 03-FEB-08:09 | 1435.25 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 212.34 | 02-FEB-23:00 |
March | 1306.65 | 01-MAR-10:09 | 730.10 | 21-MAR-07:10 | 1435.25 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 18.99 | 18-MAR-17:03 | 181.60 | 28-MAR-04:00 |
April | 1306.65 | 03-APR-09:09 | 586.82 | 04-APR-07:10 | 1435.25 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 124.24 | 30-APR-15:50 | 93.90 | 21-APR-05:00 |
May | 1306.65 | 01-MAY-09:09 | 474.56 | 26-MAY-08:30 | 1435.25 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 112.57 | 20-MAY-18:00 | 79.40 | 23-MAY-04:55 |
June | 1306.65 | 01-JUN-09:09 | 424.37 | 01-JUN-07:10 | 1435.25 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 181.24 | 17-JUN-18:27 | 40.15 | 13-JUN-04:00 |
July | 1306.65 | 03-JUL-09:09 | 484.50 | 13-JUL-15:00 | 1435.25 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 233.15 | 22-JUL-17:45 | 65.18 | 26-JUL-24:00 |
August | 1306.65 | 01-AUG-09:09 | 734.39 | 04-AUG-07:10 | 1435.25 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 208.37 | 13-AUG-16:00 | 101.02 | 05-AUG-17:50 |
September | 1306.65 | 01-SEP-09:09 | 663.50 | 29-SEP-07:10 | 1435.25 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 149.56 | 17-SEP-11:55 | 69.31 | 03-SEP-05:00 |
October | 1306.65 | 02-OCT-09:09 | 792.36 | 31-OCT-07:10 | 1435.25 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 98.12 | 01-OCT-14:58 | 195.49 | 22-OCT-14:00 |
November | 1306.65 | 01-NOV-09:09 | 889.66 | 28-NOV-16:30 | 1435.25 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 56.33 | 19-NOV-12:40 | 177.67 | 29-NOV-02:00 |
December | 1306.65 | 01-DEC-10:09 | 889.66 | 01-DEC-16:30 | 1435.25 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 20.31 | 25-DEC-16:00 | 148.82 | 07-DEC-02:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 424.37 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.15 | |||||
Maximum of Months | 1306.65 | 889.66 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 233.15 | 212.34 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.22 | 02-JAN-10:09 | 509.99 | 20-JAN-16:00 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 9.08 | 29-JAN-16:00 | 115.24 | 01-JAN-01:00 |
February | 827.22 | 01-FEB-10:09 | 471.70 | 10-FEB-08:09 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 143.49 | 02-FEB-23:00 |
March | 827.22 | 01-MAR-10:09 | 396.41 | 09-MAR-16:00 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 12.19 | 18-MAR-17:03 | 121.61 | 28-MAR-04:00 |
April | 827.22 | 03-APR-09:09 | 268.66 | 03-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 86.97 | 30-APR-15:10 | 91.28 | 16-APR-08:40 |
May | 827.22 | 01-MAY-09:09 | 293.79 | 25-MAY-15:30 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 79.85 | 20-MAY-17:50 | 52.82 | 23-MAY-04:55 |
June | 827.22 | 01-JUN-09:09 | 268.66 | 01-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 124.02 | 17-JUN-18:27 | 28.57 | 25-JUN-06:00 |
July | 827.22 | 03-JUL-09:09 | 310.28 | 13-JUL-15:00 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 157.58 | 22-JUL-17:50 | 43.52 | 26-JUL-24:00 |
August | 827.22 | 01-AUG-09:09 | 454.03 | 04-AUG-07:10 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 142.17 | 13-AUG-16:00 | 68.24 | 05-AUG-17:50 |
September | 827.22 | 01-SEP-09:09 | 309.36 | 29-SEP-14:30 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 99.58 | 17-SEP-11:55 | 46.10 | 03-SEP-05:00 |
October | 827.22 | 02-OCT-09:09 | 410.97 | 31-OCT-15:00 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 67.83 | 01-OCT-14:58 | 142.79 | 22-OCT-13:55 |
November | 827.22 | 01-NOV-09:09 | 563.23 | 28-NOV-16:30 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 31.32 | 19-NOV-15:00 | 119.29 | 29-NOV-02:00 |
December | 827.22 | 01-DEC-10:09 | 563.23 | 01-DEC-16:30 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 12.04 | 25-DEC-16:00 | 99.34 | 07-DEC-02:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.22 | 268.66 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.57 | |||||
Maximum of Months | 827.22 | 563.23 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 157.58 | 143.49 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 796.24 | 20-JAN-16:00 | 1435.24 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 6.30 | 31-JAN-14:00 | 190.01 | 01-JAN-01:00 |
February | 1306.65 | 01-FEB-10:09 | 756.28 | 10-FEB-08:09 | 1435.24 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 229.52 | 02-FEB-23:00 |
March | 1306.65 | 01-MAR-10:09 | 706.07 | 21-MAR-07:10 | 1435.24 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 13.30 | 15-MAR-13:00 | 186.07 | 28-MAR-04:00 |
April | 1306.65 | 03-APR-09:09 | 605.40 | 04-APR-07:10 | 1435.24 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 124.08 | 30-APR-15:46 | 94.61 | 21-APR-05:00 |
May | 1306.65 | 01-MAY-09:09 | 474.57 | 26-MAY-08:30 | 1435.24 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 113.56 | 20-MAY-18:40 | 79.38 | 23-MAY-04:55 |
June | 1306.65 | 01-JUN-09:09 | 471.17 | 27-JUN-07:10 | 1435.24 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 183.15 | 17-JUN-18:27 | 39.91 | 13-JUN-04:00 |
July | 1306.65 | 03-JUL-09:09 | 591.77 | 27-JUL-07:10 | 1435.24 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 234.50 | 22-JUL-17:45 | 64.81 | 26-JUL-24:00 |
August | 1306.65 | 01-AUG-09:09 | 737.51 | 04-AUG-07:10 | 1435.24 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 207.55 | 13-AUG-16:00 | 104.15 | 05-AUG-17:40 |
September | 1306.65 | 01-SEP-09:09 | 584.43 | 18-SEP-07:10 | 1435.24 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 144.98 | 17-SEP-12:30 | 70.23 | 03-SEP-05:00 |
October | 1306.65 | 02-OCT-09:09 | 685.78 | 27-OCT-07:10 | 1435.24 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 94.06 | 01-OCT-14:58 | 233.89 | 22-OCT-13:55 |
November | 1306.65 | 01-NOV-09:09 | 889.66 | 28-NOV-16:30 | 1435.24 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10.29 | 01-NOV-16:00 | 186.05 | 29-NOV-02:00 |
December | 1306.65 | 01-DEC-10:09 | 889.66 | 01-DEC-16:30 | 1435.24 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2.62 | 21-DEC-15:00 | 154.56 | 07-DEC-02:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 471.17 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39.91 | |||||
Maximum of Months | 1306.65 | 889.66 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 234.50 | 233.89 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.17 | 02-JAN-10:09 | 520.44 | 20-JAN-08:09 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 17.79 | 16-JAN-12:00 | 118.72 | 01-JAN-01:00 |
February | 827.17 | 01-FEB-10:09 | 492.41 | 03-FEB-08:09 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 147.23 | 02-FEB-23:00 |
March | 827.17 | 01-MAR-10:09 | 492.78 | 21-MAR-07:10 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 8.86 | 15-MAR-13:00 | 123.44 | 28-MAR-04:00 |
April | 827.17 | 03-APR-09:09 | 417.37 | 04-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 81.85 | 30-APR-15:44 | 66.20 | 26-APR-21:20 |
May | 827.17 | 01-MAY-09:09 | 349.68 | 05-MAY-07:10 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 78.82 | 20-MAY-18:30 | 54.02 | 23-MAY-04:55 |
June | 827.17 | 01-JUN-09:09 | 339.62 | 27-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 123.01 | 17-JUN-18:27 | 27.86 | 13-JUN-04:00 |
July | 827.17 | 03-JUL-09:09 | 388.97 | 27-JUL-07:10 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 152.96 | 22-JUL-18:00 | 46.38 | 26-JUL-24:00 |
August | 827.17 | 01-AUG-09:09 | 471.18 | 04-AUG-07:10 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 138.37 | 13-AUG-16:00 | 68.91 | 05-AUG-17:40 |
September | 827.17 | 01-SEP-09:09 | 450.36 | 29-SEP-07:10 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 108.34 | 17-SEP-11:55 | 45.99 | 03-SEP-05:00 |
October | 827.17 | 02-OCT-09:09 | 506.11 | 27-OCT-07:10 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 67.70 | 01-OCT-14:58 | 133.48 | 22-OCT-14:00 |
November | 827.17 | 01-NOV-09:09 | 563.19 | 28-NOV-16:30 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 39.43 | 19-NOV-12:20 | 118.87 | 29-NOV-02:00 |
December | 827.17 | 01-DEC-10:09 | 563.19 | 01-DEC-16:30 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 9.25 | 25-DEC-14:00 | 99.99 | 07-DEC-02:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.17 | 339.62 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.86 | |||||
Maximum of Months | 827.17 | 563.19 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 152.96 | 147.23 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 810.13 | 20-JAN-08:09 | 1435.25 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 9.47 | 16-JAN-12:00 | 102.87 | 01-JAN-01:00 |
February | 1306.65 | 01-FEB-10:09 | 771.80 | 03-FEB-08:09 | 1435.25 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 120.56 | 02-FEB-23:00 |
March | 1306.65 | 01-MAR-10:09 | 722.38 | 21-MAR-07:10 | 1435.25 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 14.22 | 18-MAR-17:03 | 102.05 | 28-MAR-04:00 |
April | 1306.65 | 03-APR-09:09 | 571.10 | 04-APR-07:10 | 1435.25 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 79.46 | 30-APR-15:10 | 53.73 | 21-APR-05:00 |
May | 1306.65 | 01-MAY-09:09 | 470.75 | 26-MAY-08:30 | 1435.25 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 70.05 | 20-MAY-18:00 | 41.75 | 23-MAY-05:00 |
June | 1306.65 | 01-JUN-09:09 | 424.37 | 01-JUN-07:10 | 1435.25 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 102.43 | 17-JUN-17:03 | 21.40 | 13-JUN-04:00 |
July | 1306.65 | 03-JUL-09:09 | 481.20 | 13-JUL-15:00 | 1435.25 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 126.38 | 22-JUL-18:00 | 35.09 | 26-JUL-24:00 |
August | 1306.65 | 01-AUG-09:09 | 727.43 | 04-AUG-07:10 | 1435.25 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 115.59 | 13-AUG-16:00 | 53.21 | 05-AUG-17:50 |
September | 1306.65 | 01-SEP-09:09 | 652.87 | 29-SEP-07:10 | 1435.25 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.82 | 17-SEP-11:55 | 40.70 | 03-SEP-05:00 |
October | 1306.65 | 02-OCT-09:09 | 786.34 | 31-OCT-07:10 | 1435.25 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 52.38 | 01-OCT-14:40 | 108.47 | 22-OCT-14:00 |
November | 1306.65 | 01-NOV-09:09 | 889.66 | 28-NOV-16:30 | 1435.25 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 25.76 | 19-NOV-14:50 | 107.96 | 29-NOV-02:00 |
December | 1306.65 | 01-DEC-10:09 | 889.66 | 01-DEC-16:30 | 1435.25 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 9.80 | 25-DEC-15:52 | 89.55 | 07-DEC-02:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 424.37 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.40 | |||||
Maximum of Months | 1306.65 | 889.66 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 126.38 | 120.56 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.22 | 02-JAN-10:09 | 508.08 | 20-JAN-16:00 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3.84 | 29-JAN-16:00 | 72.51 | 01-JAN-01:00 |
February | 827.22 | 01-FEB-10:09 | 468.19 | 10-FEB-08:09 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 84.42 | 02-FEB-23:00 |
March | 827.22 | 01-MAR-10:09 | 390.84 | 09-MAR-16:00 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 8.02 | 18-MAR-17:03 | 70.89 | 28-MAR-04:00 |
April | 827.22 | 03-APR-09:09 | 268.66 | 03-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 47.78 | 30-APR-15:50 | 44.61 | 16-APR-08:30 |
May | 827.22 | 01-MAY-09:09 | 291.36 | 25-MAY-15:30 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 46.35 | 20-MAY-17:50 | 28.68 | 23-MAY-05:00 |
June | 827.22 | 01-JUN-09:09 | 268.66 | 01-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 67.78 | 17-JUN-19:00 | 15.25 | 25-JUN-06:00 |
July | 827.22 | 03-JUL-09:09 | 308.57 | 13-JUL-15:00 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 86.14 | 22-JUL-18:00 | 24.51 | 26-JUL-24:00 |
August | 827.22 | 01-AUG-09:09 | 449.89 | 04-AUG-07:10 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 77.02 | 13-AUG-16:00 | 36.62 | 05-AUG-17:50 |
September | 827.22 | 01-SEP-09:09 | 307.89 | 29-SEP-14:30 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 53.51 | 17-SEP-12:00 | 27.91 | 03-SEP-05:00 |
October | 827.22 | 02-OCT-09:09 | 406.74 | 31-OCT-15:00 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 35.76 | 01-OCT-14:38 | 78.92 | 22-OCT-14:00 |
November | 827.22 | 01-NOV-09:09 | 563.23 | 28-NOV-16:30 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 12.74 | 19-NOV-15:10 | 74.40 | 29-NOV-02:00 |
December | 827.22 | 01-DEC-10:09 | 563.23 | 01-DEC-16:30 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 5.10 | 25-DEC-16:10 | 60.96 | 07-DEC-02:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.22 | 268.66 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.25 | |||||
Maximum of Months | 827.22 | 563.23 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 86.14 | 84.42 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 791.96 | 20-JAN-16:00 | 1435.24 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4632.38 | 31-JAN-17:10 | 18236.06 | 12-JAN-07:02 |
February | 1306.65 | 01-FEB-10:09 | 750.19 | 10-FEB-08:09 | 1435.24 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 18721.02 | 01-FEB-07:01 |
March | 1306.65 | 01-MAR-10:09 | 697.25 | 21-MAR-07:10 | 1435.24 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 5343.57 | 20-MAR-17:00 | 21225.34 | 27-MAR-06:01 |
April | 1306.65 | 03-APR-09:09 | 590.99 | 04-APR-07:10 | 1435.24 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 11312.52 | 14-APR-16:02 | 13599.12 | 21-APR-06:03 |
May | 1306.65 | 01-MAY-09:09 | 470.75 | 26-MAY-08:30 | 1435.24 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 13368.78 | 31-MAY-16:02 | 10035.88 | 01-MAY-06:02 |
June | 1306.65 | 01-JUN-09:09 | 468.59 | 27-JUN-07:10 | 1435.24 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18487.55 | 28-JUN-16:01 | 4330.00 | 21-JUN-06:03 |
July | 1306.65 | 03-JUL-09:09 | 579.17 | 27-JUL-07:10 | 1435.24 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 15514.59 | 20-JUL-16:01 | 1911.50 | 03-JUL-06:03 |
August | 1306.65 | 01-AUG-09:09 | 730.72 | 04-AUG-07:10 | 1435.24 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 17191.58 | 25-AUG-16:01 | 4753.64 | 24-AUG-06:03 |
September | 1306.65 | 01-SEP-09:09 | 568.24 | 18-SEP-07:10 | 1435.24 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 13627.41 | 08-SEP-16:01 | 6930.34 | 22-SEP-06:02 |
October | 1306.65 | 02-OCT-09:09 | 676.20 | 27-OCT-07:10 | 1435.24 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10831.28 | 03-OCT-16:02 | 18954.54 | 25-OCT-06:01 |
November | 1306.65 | 01-NOV-09:09 | 889.66 | 28-NOV-16:30 | 1435.24 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3328.50 | 01-NOV-16:05 | 19501.37 | 24-NOV-07:01 |
December | 1306.65 | 01-DEC-10:09 | 889.66 | 01-DEC-16:30 | 1435.24 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 326.82 | 21-DEC-15:00 | 24521.17 | 05-DEC-07:01 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 468.59 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1911.50 | |||||
Maximum of Months | 1306.65 | 889.66 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 18487.55 | 24521.17 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.17 | 02-JAN-10:09 | 518.69 | 20-JAN-08:09 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4.87 | 16-JAN-12:10 | 74.36 | 01-JAN-01:00 |
February | 827.17 | 01-FEB-10:09 | 489.90 | 03-FEB-08:09 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 85.60 | 02-FEB-23:00 |
March | 827.17 | 01-MAR-10:09 | 490.26 | 21-MAR-07:10 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4.79 | 15-MAR-13:00 | 71.64 | 28-MAR-04:00 |
April | 827.17 | 03-APR-09:09 | 411.05 | 04-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 43.52 | 30-APR-15:44 | 37.23 | 21-APR-05:00 |
May | 827.17 | 01-MAY-09:09 | 341.65 | 05-MAY-07:10 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 41.17 | 20-MAY-18:40 | 29.51 | 23-MAY-05:00 |
June | 827.17 | 01-JUN-09:09 | 331.76 | 27-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 67.93 | 17-JUN-17:03 | 15.74 | 13-JUN-04:00 |
July | 827.17 | 03-JUL-09:09 | 382.93 | 27-JUL-07:10 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 81.72 | 22-JUL-18:00 | 25.79 | 26-JUL-24:00 |
August | 827.17 | 01-AUG-09:09 | 467.91 | 04-AUG-07:10 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 73.91 | 13-AUG-16:00 | 36.57 | 05-AUG-17:50 |
September | 827.17 | 01-SEP-09:09 | 446.33 | 29-SEP-07:10 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 55.99 | 17-SEP-11:55 | 27.62 | 03-SEP-05:00 |
October | 827.17 | 02-OCT-09:09 | 503.61 | 27-OCT-07:10 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 35.35 | 01-OCT-14:38 | 75.02 | 22-OCT-14:00 |
November | 827.17 | 01-NOV-09:09 | 563.19 | 28-NOV-16:30 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.59 | 19-NOV-12:43 | 74.32 | 29-NOV-02:00 |
December | 827.17 | 01-DEC-10:09 | 563.19 | 01-DEC-16:30 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3.67 | 25-DEC-13:42 | 60.93 | 07-DEC-02:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.17 | 331.76 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.74 | |||||
Maximum of Months | 827.17 | 563.19 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 81.72 | 85.60 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 813.93 | 20-JAN-08:09 | 1435.25 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 14.16 | 16-JAN-12:00 | 159.16 | 01-JAN-01:00 |
February | 1306.65 | 01-FEB-10:09 | 776.68 | 03-FEB-08:09 | 1435.25 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 192.77 | 02-FEB-23:00 |
March | 1306.65 | 01-MAR-10:09 | 730.09 | 21-MAR-07:10 | 1435.25 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 17.43 | 18-MAR-17:03 | 163.83 | 28-MAR-04:00 |
April | 1306.65 | 03-APR-09:09 | 586.82 | 04-APR-07:10 | 1435.25 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 111.96 | 30-APR-15:00 | 84.62 | 21-APR-05:00 |
May | 1306.65 | 01-MAY-09:09 | 474.56 | 26-MAY-08:30 | 1435.25 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 101.02 | 20-MAY-18:00 | 70.17 | 23-MAY-04:55 |
June | 1306.65 | 01-JUN-09:09 | 424.37 | 01-JUN-07:10 | 1435.25 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 154.66 | 17-JUN-17:03 | 35.19 | 13-JUN-04:00 |
July | 1306.65 | 03-JUL-09:09 | 484.50 | 13-JUL-15:00 | 1435.25 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 193.16 | 22-JUL-18:00 | 54.49 | 26-JUL-24:00 |
August | 1306.65 | 01-AUG-09:09 | 734.38 | 04-AUG-07:10 | 1435.25 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 178.61 | 13-AUG-16:00 | 82.19 | 05-AUG-17:50 |
September | 1306.65 | 01-SEP-09:09 | 663.49 | 29-SEP-07:10 | 1435.25 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 128.50 | 17-SEP-12:00 | 59.59 | 03-SEP-05:00 |
October | 1306.65 | 02-OCT-09:09 | 792.36 | 31-OCT-07:10 | 1435.25 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 81.32 | 01-OCT-14:48 | 165.10 | 22-OCT-14:00 |
November | 1306.65 | 01-NOV-09:09 | 889.66 | 28-NOV-16:30 | 1435.25 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 42.55 | 19-NOV-15:00 | 162.48 | 29-NOV-02:00 |
December | 1306.65 | 01-DEC-10:09 | 889.66 | 01-DEC-16:30 | 1435.25 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 15.51 | 25-DEC-16:00 | 135.58 | 07-DEC-02:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 424.37 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.19 | |||||
Maximum of Months | 1306.65 | 889.66 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 193.16 | 192.77 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 805.43 | 02-JAN-08:09 | 509.98 | 20-JAN-16:00 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 6.67 | 29-JAN-16:00 | 107.91 | 01-JAN-01:00 |
February | 805.43 | 01-FEB-08:09 | 471.69 | 10-FEB-08:09 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 129.49 | 02-FEB-23:00 |
March | 805.43 | 01-MAR-08:09 | 396.42 | 09-MAR-16:00 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 11.34 | 18-MAR-17:03 | 109.48 | 28-MAR-04:00 |
April | 805.43 | 03-APR-07:10 | 268.66 | 03-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 72.41 | 30-APR-15:40 | 79.74 | 16-APR-09:00 |
May | 805.43 | 01-MAY-07:10 | 293.78 | 25-MAY-15:30 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 70.78 | 20-MAY-17:50 | 46.65 | 23-MAY-04:55 |
June | 805.43 | 01-JUN-07:10 | 268.66 | 01-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 106.07 | 17-JUN-19:00 | 24.70 | 25-JUN-06:00 |
July | 805.43 | 03-JUL-07:10 | 310.28 | 13-JUL-15:00 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 135.48 | 22-JUL-18:00 | 36.35 | 26-JUL-24:00 |
August | 805.43 | 01-AUG-07:10 | 454.03 | 04-AUG-07:10 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 120.68 | 13-AUG-16:00 | 55.52 | 05-AUG-17:50 |
September | 805.43 | 01-SEP-07:10 | 309.36 | 29-SEP-14:30 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 85.18 | 17-SEP-12:00 | 39.63 | 03-SEP-05:00 |
October | 805.43 | 02-OCT-07:10 | 410.97 | 31-OCT-15:00 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 56.33 | 01-OCT-14:50 | 119.32 | 22-OCT-13:55 |
November | 805.43 | 01-NOV-07:10 | 563.23 | 28-NOV-16:30 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.40 | 19-NOV-15:00 | 108.62 | 29-NOV-02:00 |
December | 805.43 | 01-DEC-08:09 | 563.23 | 01-DEC-16:30 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 9.39 | 25-DEC-16:00 | 90.42 | 07-DEC-02:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 805.43 | 268.66 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.70 | |||||
Maximum of Months | 805.43 | 563.23 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 135.48 | 129.49 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 796.24 | 20-JAN-16:00 | 1435.24 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 5.28 | 31-JAN-14:00 | 175.71 | 01-JAN-01:00 |
February | 1306.65 | 01-FEB-10:09 | 756.27 | 10-FEB-08:09 | 1435.24 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 205.90 | 02-FEB-23:00 |
March | 1306.65 | 01-MAR-10:09 | 706.06 | 21-MAR-07:10 | 1435.24 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 11.16 | 15-MAR-13:00 | 167.39 | 28-MAR-04:00 |
April | 1306.65 | 03-APR-09:09 | 605.41 | 04-APR-07:10 | 1435.24 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 102.96 | 30-APR-15:34 | 85.19 | 21-APR-05:00 |
May | 1306.65 | 01-MAY-09:09 | 474.56 | 26-MAY-08:30 | 1435.24 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 99.96 | 20-MAY-18:40 | 70.16 | 23-MAY-04:55 |
June | 1306.65 | 01-JUN-09:09 | 471.16 | 27-JUN-07:10 | 1435.24 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 155.62 | 17-JUN-19:00 | 34.99 | 13-JUN-04:00 |
July | 1306.65 | 03-JUL-09:09 | 591.78 | 27-JUL-07:10 | 1435.24 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 197.20 | 22-JUL-18:00 | 54.18 | 26-JUL-24:00 |
August | 1306.65 | 01-AUG-09:09 | 737.50 | 04-AUG-07:10 | 1435.24 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 173.59 | 13-AUG-16:00 | 84.62 | 05-AUG-17:50 |
September | 1306.65 | 01-SEP-09:09 | 584.43 | 18-SEP-07:10 | 1435.24 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 120.73 | 17-SEP-11:55 | 60.36 | 03-SEP-05:00 |
October | 1306.65 | 02-OCT-09:09 | 685.78 | 27-OCT-07:10 | 1435.24 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 78.48 | 01-OCT-14:48 | 194.13 | 22-OCT-14:00 |
November | 1306.65 | 01-NOV-09:09 | 889.66 | 28-NOV-16:30 | 1435.24 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 8.60 | 01-NOV-16:00 | 168.96 | 29-NOV-02:00 |
December | 1306.65 | 01-DEC-10:09 | 889.66 | 01-DEC-16:30 | 1435.24 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2.21 | 21-DEC-15:00 | 140.46 | 07-DEC-02:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 471.16 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.99 | |||||
Maximum of Months | 1306.65 | 889.66 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 197.20 | 205.90 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.17 | 02-JAN-10:09 | 520.43 | 20-JAN-08:09 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 10.14 | 16-JAN-12:00 | 110.61 | 01-JAN-01:00 |
February | 827.17 | 01-FEB-10:09 | 492.41 | 03-FEB-08:09 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 132.68 | 02-FEB-23:00 |
March | 827.17 | 01-MAR-10:09 | 492.77 | 21-MAR-07:10 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 7.44 | 15-MAR-13:00 | 111.09 | 28-MAR-04:00 |
April | 827.17 | 03-APR-09:09 | 417.38 | 04-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 69.08 | 30-APR-14:53 | 57.04 | 21-APR-05:00 |
May | 827.17 | 01-MAY-09:09 | 349.69 | 05-MAY-07:10 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 64.05 | 20-MAY-18:30 | 47.69 | 23-MAY-04:55 |
June | 827.17 | 01-JUN-09:09 | 339.62 | 27-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 104.72 | 17-JUN-17:03 | 24.35 | 13-JUN-04:00 |
July | 827.17 | 03-JUL-09:09 | 388.97 | 27-JUL-07:10 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 127.63 | 22-JUL-18:00 | 38.71 | 26-JUL-24:00 |
August | 827.17 | 01-AUG-09:09 | 471.17 | 04-AUG-07:10 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 115.44 | 13-AUG-16:00 | 56.11 | 05-AUG-17:50 |
September | 827.17 | 01-SEP-09:09 | 450.35 | 29-SEP-07:10 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 91.00 | 17-SEP-11:55 | 39.58 | 03-SEP-05:00 |
October | 827.17 | 02-OCT-09:09 | 506.11 | 27-OCT-07:10 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 55.63 | 01-OCT-14:48 | 112.60 | 22-OCT-14:00 |
November | 827.17 | 01-NOV-09:09 | 563.19 | 28-NOV-16:30 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 27.35 | 19-NOV-12:20 | 108.57 | 29-NOV-02:00 |
December | 827.17 | 01-DEC-10:09 | 563.19 | 01-DEC-16:30 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 5.76 | 25-DEC-13:42 | 90.93 | 07-DEC-02:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.17 | 339.62 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.35 | |||||
Maximum of Months | 827.17 | 563.19 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 127.63 | 132.68 |
Report: PeakSpaceGainsMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.89 | 31-JAN-14:00 | 238.21 | 01-JAN-01:00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 278.21 | 02-FEB-23:00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.84 | 18-MAR-17:03 | 232.65 | 28-MAR-04:00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 139.85 | 30-APR-14:52 | 118.62 | 21-APR-05:00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 128.25 | 20-MAY-17:02 | 93.95 | 23-MAY-05:00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 204.60 | 17-JUN-17:03 | 46.04 | 13-JUN-04:00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 254.42 | 22-JUL-18:00 | 70.17 | 26-JUL-24:00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 221.27 | 13-AUG-16:00 | 107.91 | 05-AUG-17:50 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 162.00 | 17-SEP-12:00 | 80.07 | 03-SEP-05:00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 99.59 | 01-OCT-14:50 | 217.49 | 22-OCT-14:00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.42 | 19-NOV-14:53 | 233.94 | 29-NOV-02:00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.60 | 25-DEC-15:52 | 195.94 | 07-DEC-02:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46.04 | ||
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 254.42 | 278.21 |
Report: PeakSpaceGainsMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.19 | 31-JAN-14:00 | 283.86 | 01-JAN-01:00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 345.67 | 02-FEB-23:00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.50 | 18-MAR-17:03 | 290.24 | 28-MAR-04:00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 178.21 | 30-APR-15:00 | 150.49 | 21-APR-05:00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 164.80 | 20-MAY-17:02 | 122.94 | 23-MAY-04:55 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 263.68 | 17-JUN-17:03 | 59.67 | 13-JUN-04:00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 327.06 | 22-JUL-18:00 | 90.24 | 26-JUL-24:00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 281.80 | 13-AUG-16:00 | 138.01 | 05-AUG-17:50 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 211.89 | 17-SEP-12:00 | 101.33 | 03-SEP-05:00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 129.98 | 01-OCT-14:32 | 266.74 | 22-OCT-14:00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 53.61 | 19-NOV-14:50 | 287.04 | 29-NOV-02:00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.16 | 25-DEC-15:52 | 241.17 | 07-DEC-02:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 59.67 | ||
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 327.06 | 345.67 |
Report: PeakSpaceGainsMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.02 | 31-JAN-14:00 | 252.56 | 01-JAN-01:00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 314.33 | 02-FEB-23:00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.22 | 15-MAR-13:00 | 266.46 | 28-MAR-04:00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 135.28 | 30-APR-16:00 | 139.57 | 26-APR-21:03 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 143.14 | 20-MAY-18:50 | 110.91 | 23-MAY-04:55 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 262.90 | 17-JUN-17:03 | 52.90 | 13-JUN-04:00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 315.89 | 22-JUL-18:00 | 94.30 | 26-JUL-24:00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 255.37 | 13-AUG-16:00 | 165.79 | 05-AUG-17:40 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 204.29 | 17-SEP-12:00 | 101.53 | 03-SEP-05:00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 118.48 | 01-OCT-14:30 | 346.88 | 22-OCT-13:55 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.88 | 19-NOV-15:10 | 259.21 | 29-NOV-02:00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.23 | 25-DEC-13:42 | 218.41 | 07-DEC-02:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52.90 | ||
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 315.89 | 346.88 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 33662.21 | 30-JAN-06:02 | 3176.32 | 2344.59 | 24947.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 35875.96 | 01-FEB-06:02 | 3176.32 | 2344.59 | 24947.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 35967.49 | 22-MAR-05:03 | 2541.06 | 1875.67 | 19958.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 39790.42 | 29-APR-05:03 | 2541.06 | 1875.67 | 19958.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 38832.37 | 08-MAY-04:03 | 0.00 | 1875.67 | 17622.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 41447.64 | 20-JUN-04:03 | 0.00 | 1875.67 | 17622.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 41109.86 | 06-JUL-04:03 | 0.00 | 1875.67 | 17622.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 40759.11 | 22-AUG-04:03 | 0.00 | 1875.67 | 17622.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 41263.74 | 12-SEP-04:03 | 0.00 | 1875.67 | 17622.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 41449.44 | 10-OCT-04:03 | 0.00 | 1875.67 | 17622.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 39181.57 | 17-NOV-06:02 | 3176.32 | 2344.59 | 24947.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 35114.71 | 27-DEC-06:02 | 3176.32 | 2344.59 | 24947.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 33662.21 | 0.00 | 1875.67 | 17622.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 41449.44 | 3176.32 | 2344.59 | 24947.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5597.80 | 31-JAN-16:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.79 | 0.00 |
February | 3976.71 | 23-FEB-14:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.09 |
March | 6799.91 | 20-MAR-14:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.91 | 0.00 |
April | 10868.70 | 14-APR-15:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.36 | 0.00 |
May | 10696.53 | 15-MAY-15:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.82 | 0.00 |
June | 12922.27 | 28-JUN-14:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 71.40 | 0.00 |
July | 12221.86 | 10-JUL-14:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.09 | 0.00 |
August | 12223.60 | 25-AUG-15:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39.38 | 0.00 |
September | 11266.29 | 07-SEP-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.51 | 0.00 |
October | 10206.31 | 02-OCT-14:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.22 | 0.00 |
November | 6759.90 | 01-NOV-15:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.49 | 0.00 |
December | 4225.08 | 22-DEC-16:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.62 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 3976.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 12922.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 71.40 | 22.09 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1755.36 | 27-JAN-17:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.68 | 0.00 |
February | 1209.14 | 08-FEB-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.83 |
March | 2235.42 | 20-MAR-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.08 | 0.00 |
April | 4208.91 | 24-APR-15:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.27 | 0.00 |
May | 4616.89 | 08-MAY-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.43 | 0.00 |
June | 5670.70 | 19-JUN-12:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 57.17 | 0.00 |
July | 5473.80 | 31-JUL-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38.45 | 0.00 |
August | 5614.44 | 14-AUG-15:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.57 | 0.00 |
September | 5284.05 | 05-SEP-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.48 | 0.00 |
October | 5076.95 | 02-OCT-15:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.70 | 0.00 |
November | 2543.09 | 01-NOV-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.35 | 0.00 |
December | 2245.33 | 14-DEC-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.12 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 1209.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 5670.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 57.17 | 51.12 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2548.79 | 27-JAN-17:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.89 | 0.00 |
February | 2405.85 | 01-FEB-07:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39.05 |
March | 2842.71 | 20-MAR-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.89 | 0.00 |
April | 4596.90 | 24-APR-12:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.47 | 0.00 |
May | 5193.97 | 08-MAY-12:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.78 | 0.00 |
June | 7474.02 | 19-JUN-12:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43.77 | 0.00 |
July | 7131.57 | 10-JUL-12:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.97 | 0.00 |
August | 7163.26 | 14-AUG-12:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.65 | 0.00 |
September | 6265.29 | 06-SEP-17:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.29 | 0.00 |
October | 5158.27 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.59 | 0.00 |
November | 3328.43 | 02-NOV-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.48 | 0.00 |
December | 2505.43 | 06-DEC-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.74 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 2405.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 7474.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43.77 | 39.05 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 12419.23 | 27-JAN-17:00 | 6035.01 | 4220.20 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 11353.50 | 01-FEB-17:00 | 6035.01 | 4220.20 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 15500.71 | 20-MAR-05:03 | 1905.79 | 1406.75 | 9077.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 29936.71 | 26-APR-05:03 | 2541.06 | 1875.67 | 12103.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 30696.50 | 30-MAY-04:03 | 0.00 | 1875.67 | 9768.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 30695.17 | 12-JUN-04:03 | 0.00 | 1875.67 | 9768.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 30489.99 | 03-JUL-04:03 | 0.00 | 1875.67 | 9768.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 29912.03 | 30-AUG-05:03 | 2541.06 | 1875.67 | 12103.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 31049.19 | 11-SEP-04:02 | 0.00 | 2344.59 | 12210.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 29971.90 | 06-OCT-05:03 | 2541.06 | 1875.67 | 12103.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 20612.57 | 03-NOV-05:03 | 2541.06 | 1875.67 | 12103.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 11371.75 | 26-DEC-17:00 | 6035.01 | 4220.20 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 11353.50 | 0.00 | 1406.75 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 31049.19 | 6035.01 | 4220.20 | 12210.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 12351.00 | 27-JAN-17:00 | 6035.01 | 4220.20 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 10529.77 | 01-FEB-17:00 | 6035.01 | 4220.20 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 14483.53 | 17-MAR-16:00 | 6035.01 | 4220.20 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 32012.29 | 25-APR-05:03 | 2541.06 | 1875.67 | 12103.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 31811.66 | 08-MAY-04:03 | 0.00 | 1875.67 | 9768.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 33625.77 | 26-JUN-04:03 | 0.00 | 1875.67 | 9768.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 33415.84 | 05-JUL-04:02 | 0.00 | 2344.59 | 12210.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 33146.59 | 21-AUG-04:02 | 0.00 | 2344.59 | 12210.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 34596.36 | 11-SEP-04:02 | 0.00 | 2344.59 | 12210.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 32716.54 | 03-OCT-05:03 | 2541.06 | 1875.67 | 12103.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 14824.06 | 01-NOV-16:00 | 6035.01 | 4220.20 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 10482.44 | 22-DEC-17:00 | 6035.01 | 4220.20 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 10482.44 | 0.00 | 1875.67 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 34596.36 | 6035.01 | 4220.20 | 12210.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2801.76 | 31-JAN-16:30 | 1272.23 | 455.45 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 5.33 | 0.00 |
February | 2070.18 | 22-FEB-16:30 | 1272.23 | 462.43 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.48 |
March | 4080.99 | 20-MAR-14:50 | 1272.23 | 424.37 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 3.46 | 0.00 |
April | 6090.94 | 25-APR-14:50 | 1272.23 | 424.37 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 24.35 | 0.00 |
May | 10042.56 | 07-MAY-17:32 | 0.00 | 141.44 | 2316.62 | 0.00 | 0.00 | 0.00 | 0.00 | 88.31 | 0.00 |
June | 12762.68 | 25-JUN-18:22 | 0.00 | 141.44 | 2316.62 | 0.00 | 0.00 | 0.00 | 0.00 | 136.73 | 0.00 |
July | 13009.40 | 16-JUL-15:12 | 401.76 | 141.44 | 2870.49 | 0.00 | 0.00 | 0.00 | 0.00 | 60.83 | 0.00 |
August | 12602.75 | 13-AUG-16:22 | 401.76 | 141.44 | 2870.49 | 0.00 | 0.00 | 0.00 | 0.00 | 186.99 | 0.00 |
September | 12105.13 | 17-SEP-15:02 | 267.84 | 94.29 | 1913.66 | 0.00 | 0.00 | 0.00 | 0.00 | 73.50 | 0.00 |
October | 10917.20 | 01-OCT-13:32 | 267.84 | 94.29 | 1913.66 | 0.00 | 0.00 | 0.00 | 0.00 | 83.26 | 0.00 |
November | 4006.36 | 01-NOV-15:30 | 1272.23 | 451.14 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 8.76 | 0.00 |
December | 1944.54 | 22-DEC-16:40 | 1272.23 | 649.50 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.23 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1944.54 | 0.00 | 94.29 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 13009.40 | 1272.23 | 649.50 | 2870.49 | 0.00 | 0.00 | 0.00 | 0.00 | 186.99 | 9.48 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2806.21 | 27-JAN-10:30 | 827.22 | 268.66 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.72 |
February | 3023.44 | 23-FEB-10:30 | 827.22 | 268.66 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.61 |
March | 4361.68 | 23-MAR-10:30 | 805.43 | 268.66 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.11 |
April | 11052.46 | 30-APR-08:23 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.25 |
May | 11897.64 | 14-MAY-10:02 | 211.95 | 74.62 | 1514.29 | 0.00 | 0.00 | 0.00 | 0.00 | 3.17 | 0.00 |
June | 12198.37 | 18-JUN-09:42 | 254.35 | 89.54 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 23.69 | 0.00 |
July | 11895.24 | 23-JUL-09:32 | 211.95 | 74.62 | 1514.29 | 0.00 | 0.00 | 0.00 | 0.00 | 16.32 | 0.00 |
August | 11973.20 | 13-AUG-09:42 | 211.95 | 74.62 | 1514.29 | 0.00 | 0.00 | 0.00 | 0.00 | 11.91 | 0.00 |
September | 11216.48 | 10-SEP-10:22 | 211.95 | 74.62 | 1514.29 | 0.00 | 0.00 | 0.00 | 0.00 | 24.53 | 0.00 |
October | 8875.99 | 01-OCT-13:32 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 55.26 | 0.00 |
November | 3615.69 | 01-NOV-10:20 | 805.43 | 268.66 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.34 |
December | 1814.22 | 25-DEC-15:52 | 211.95 | 82.69 | 1514.29 | 0.00 | 0.00 | 0.00 | 0.00 | 8.78 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1814.22 | 169.56 | 59.70 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 12198.37 | 827.22 | 268.66 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 55.26 | 9.25 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 14621.75 | 16-JAN-15:32 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.33 |
February | 9055.25 | 28-FEB-14:10 | 1306.65 | 424.37 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.77 |
March | 8416.57 | 16-MAR-13:40 | 1306.65 | 424.37 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 6.07 | 0.00 |
April | 14485.15 | 23-APR-14:02 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 37.59 | 0.00 |
May | 13833.87 | 14-MAY-15:22 | 401.76 | 141.44 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 33.14 | 0.00 |
June | 13912.76 | 04-JUN-16:41 | 468.72 | 165.01 | 3348.89 | 0.00 | 0.00 | 0.00 | 0.00 | 101.95 | 0.00 |
July | 14591.62 | 16-JUL-15:12 | 401.76 | 141.44 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 60.04 | 0.00 |
August | 14298.97 | 13-AUG-14:22 | 334.80 | 117.87 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 111.53 | 0.00 |
September | 14754.36 | 10-SEP-13:02 | 334.80 | 117.87 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 76.06 | 0.00 |
October | 15970.78 | 09-OCT-13:52 | 401.76 | 141.44 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 6.96 | 0.00 |
November | 14700.99 | 19-NOV-14:13 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.65 |
December | 15291.01 | 25-DEC-13:52 | 334.80 | 117.87 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.20 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 8416.57 | 267.84 | 94.29 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 15970.78 | 1306.65 | 424.37 | 3348.89 | 0.00 | 0.00 | 0.00 | 0.00 | 111.53 | 28.33 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5678.23 | 31-JAN-16:30 | 805.38 | 268.64 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 3.55 | 0.00 |
February | 5594.53 | 22-FEB-16:30 | 805.38 | 268.64 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.32 |
March | 8221.46 | 18-MAR-17:08 | 169.55 | 59.69 | 1211.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.22 | 0.00 |
April | 13487.49 | 30-APR-17:02 | 0.00 | 89.54 | 1466.51 | 0.00 | 0.00 | 0.00 | 0.00 | 45.34 | 0.00 |
May | 13713.05 | 28-MAY-17:12 | 0.00 | 89.54 | 1466.51 | 0.00 | 0.00 | 0.00 | 0.00 | 43.47 | 0.00 |
June | 14095.46 | 25-JUN-17:01 | 0.00 | 104.46 | 1710.93 | 0.00 | 0.00 | 0.00 | 0.00 | 58.65 | 0.00 |
July | 14058.17 | 16-JUL-17:11 | 0.00 | 119.38 | 1955.35 | 0.00 | 0.00 | 0.00 | 0.00 | 91.60 | 0.00 |
August | 13896.87 | 13-AUG-17:02 | 0.00 | 89.54 | 1466.51 | 0.00 | 0.00 | 0.00 | 0.00 | 101.24 | 0.00 |
September | 13208.71 | 04-SEP-15:52 | 211.94 | 74.61 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 15.29 | 0.00 |
October | 14006.81 | 15-OCT-16:22 | 254.33 | 89.54 | 1817.13 | 0.00 | 0.00 | 0.00 | 0.00 | 11.92 | 0.00 |
November | 6913.23 | 01-NOV-16:00 | 805.38 | 268.64 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 6.87 | 0.00 |
December | 7846.93 | 25-DEC-16:33 | 169.55 | 59.69 | 1211.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.13 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 5594.53 | 0.00 | 59.69 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 14095.46 | 805.38 | 268.64 | 1955.35 | 0.00 | 0.00 | 0.00 | 0.00 | 101.24 | 10.13 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2129.87 | 27-JAN-16:30 | 1272.23 | 448.35 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 1.61 | 0.00 |
February | 1514.09 | 22-FEB-16:40 | 1272.23 | 473.99 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.78 |
March | 2752.05 | 20-MAR-14:30 | 1272.23 | 424.37 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 2.57 | 0.00 |
April | 4574.57 | 25-APR-14:50 | 1272.23 | 424.37 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 13.02 | 0.00 |
May | 5136.94 | 08-MAY-15:20 | 1272.23 | 424.37 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 7.84 | 0.00 |
June | 8351.43 | 19-JUN-06:03 | 803.52 | 424.37 | 1913.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.26 |
July | 10465.87 | 04-JUL-19:02 | 0.00 | 192.62 | 2316.62 | 0.00 | 0.00 | 0.00 | 0.00 | 50.37 | 0.00 |
August | 10353.30 | 27-AUG-17:41 | 0.00 | 175.87 | 2702.72 | 0.00 | 0.00 | 0.00 | 0.00 | 62.45 | 0.00 |
September | 8755.70 | 10-SEP-13:32 | 401.76 | 141.44 | 2870.49 | 0.00 | 0.00 | 0.00 | 0.00 | 49.83 | 0.00 |
October | 8442.61 | 02-OCT-04:02 | 0.00 | 494.26 | 2574.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.44 | 0.00 |
November | 3779.40 | 02-NOV-14:00 | 1306.65 | 424.37 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 5.08 | 0.00 |
December | 2024.26 | 26-DEC-16:20 | 1272.23 | 537.10 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1514.09 | 0.00 | 141.44 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 10465.87 | 1306.65 | 537.10 | 2870.49 | 0.00 | 0.00 | 0.00 | 0.00 | 62.45 | 4.78 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2784.79 | 27-JAN-10:30 | 827.22 | 268.66 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.04 |
February | 2500.59 | 23-FEB-10:30 | 827.22 | 268.66 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.50 |
March | 3436.77 | 23-MAR-10:30 | 805.43 | 268.66 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.59 |
April | 7988.69 | 23-APR-11:13 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 2.19 | 0.00 |
May | 10151.23 | 14-MAY-10:02 | 211.95 | 74.62 | 1514.29 | 0.00 | 0.00 | 0.00 | 0.00 | 2.36 | 0.00 |
June | 10290.80 | 18-JUN-07:12 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 11.84 | 0.00 |
July | 10829.34 | 04-JUL-09:42 | 254.35 | 89.54 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 5.52 | 0.00 |
August | 10584.19 | 27-AUG-11:02 | 211.95 | 74.62 | 1514.29 | 0.00 | 0.00 | 0.00 | 0.00 | 26.50 | 0.00 |
September | 10568.20 | 04-SEP-09:42 | 211.95 | 74.62 | 1514.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.75 |
October | 7512.27 | 02-OCT-04:02 | 0.00 | 312.91 | 1629.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.66 | 0.00 |
November | 3841.52 | 10-NOV-10:00 | 805.43 | 268.66 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.48 |
December | 2470.25 | 01-DEC-10:30 | 827.22 | 268.66 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.38 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 2470.25 | 0.00 | 59.70 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 10829.34 | 827.22 | 312.91 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 26.50 | 4.04 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 12323.83 | 16-JAN-14:23 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.62 |
February | 7810.21 | 27-FEB-13:06 | 6361.16 | 2121.83 | 7176.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1324.11 |
March | 9812.08 | 16-MAR-16:10 | 401.76 | 235.76 | 797.35 | 0.00 | 0.00 | 0.00 | 0.00 | 5247.95 | 0.00 |
April | 11324.75 | 14-APR-16:50 | 401.76 | 235.76 | 797.35 | 0.00 | 0.00 | 0.00 | 0.00 | 9591.92 | 0.00 |
May | 11776.44 | 15-MAY-17:00 | 401.76 | 235.76 | 797.35 | 0.00 | 0.00 | 0.00 | 0.00 | 11129.11 | 0.00 |
June | 13481.33 | 28-JUN-17:00 | 401.76 | 235.76 | 797.35 | 0.00 | 0.00 | 0.00 | 0.00 | 14264.41 | 0.00 |
July | 12716.14 | 20-JUL-17:00 | 401.76 | 235.76 | 797.35 | 0.00 | 0.00 | 0.00 | 0.00 | 12243.63 | 0.00 |
August | 13329.13 | 25-AUG-17:00 | 401.76 | 235.76 | 797.35 | 0.00 | 0.00 | 0.00 | 0.00 | 13426.46 | 0.00 |
September | 12812.43 | 10-SEP-13:32 | 401.76 | 141.44 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 40.71 | 0.00 |
October | 13186.92 | 09-OCT-13:42 | 401.76 | 141.44 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 4.68 | 0.00 |
November | 12381.61 | 19-NOV-14:23 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.50 |
December | 12326.73 | 24-DEC-13:43 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.92 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 7810.21 | 267.84 | 94.29 | 797.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 13481.33 | 6361.16 | 2121.83 | 7176.19 | 0.00 | 0.00 | 0.00 | 0.00 | 14264.41 | 1324.11 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 4744.83 | 24-JAN-16:40 | 805.38 | 268.64 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.38 | 0.00 |
February | 4067.97 | 22-FEB-16:30 | 805.38 | 268.64 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.31 |
March | 4830.67 | 18-MAR-17:10 | 169.55 | 59.69 | 1211.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.47 | 0.00 |
April | 11083.91 | 16-APR-17:42 | 0.00 | 74.61 | 1222.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.85 |
May | 11026.58 | 21-MAY-17:51 | 0.00 | 119.38 | 1955.35 | 0.00 | 0.00 | 0.00 | 0.00 | 17.47 | 0.00 |
June | 11274.87 | 25-JUN-17:41 | 0.00 | 104.46 | 1710.93 | 0.00 | 0.00 | 0.00 | 0.00 | 48.41 | 0.00 |
July | 11229.66 | 04-JUL-19:02 | 0.00 | 95.01 | 1466.51 | 0.00 | 0.00 | 0.00 | 0.00 | 29.77 | 0.00 |
August | 11769.39 | 27-AUG-17:41 | 0.00 | 104.46 | 1710.93 | 0.00 | 0.00 | 0.00 | 0.00 | 35.40 | 0.00 |
September | 11379.59 | 04-SEP-17:42 | 0.00 | 89.54 | 1466.51 | 0.00 | 0.00 | 0.00 | 0.00 | 11.60 | 0.00 |
October | 10954.49 | 09-OCT-15:02 | 254.33 | 89.54 | 1817.13 | 0.00 | 0.00 | 0.00 | 0.00 | 8.46 | 0.00 |
November | 6281.58 | 21-NOV-16:30 | 805.38 | 268.64 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.19 | 0.00 |
December | 7135.50 | 25-DEC-16:42 | 169.55 | 59.69 | 1211.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.27 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 4067.97 | 0.00 | 59.69 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 11769.39 | 805.38 | 268.64 | 1955.35 | 0.00 | 0.00 | 0.00 | 0.00 | 48.41 | 6.85 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2754.71 | 31-JAN-16:30 | 1272.23 | 455.44 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 4.46 | 0.00 |
February | 2026.07 | 22-FEB-16:30 | 1272.23 | 462.42 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.84 |
March | 3869.84 | 20-MAR-14:30 | 1272.23 | 424.37 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 4.00 | 0.00 |
April | 5427.66 | 25-APR-14:50 | 1272.23 | 424.37 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 20.33 | 0.00 |
May | 6400.89 | 08-MAY-06:03 | 803.52 | 424.37 | 1913.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.94 |
June | 10715.40 | 25-JUN-18:11 | 0.00 | 212.16 | 3474.93 | 0.00 | 0.00 | 0.00 | 0.00 | 118.37 | 0.00 |
July | 10663.95 | 04-JUL-19:02 | 0.00 | 214.35 | 2316.62 | 0.00 | 0.00 | 0.00 | 0.00 | 76.74 | 0.00 |
August | 10490.65 | 27-AUG-15:51 | 602.64 | 212.16 | 4305.74 | 0.00 | 0.00 | 0.00 | 0.00 | 122.16 | 0.00 |
September | 9856.39 | 10-SEP-13:32 | 401.76 | 141.44 | 2870.49 | 0.00 | 0.00 | 0.00 | 0.00 | 77.69 | 0.00 |
October | 8784.33 | 02-OCT-04:02 | 0.00 | 494.26 | 2574.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.06 | 0.00 |
November | 3728.12 | 02-NOV-14:00 | 1306.65 | 424.37 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 7.88 | 0.00 |
December | 1982.89 | 22-DEC-16:50 | 1272.23 | 699.75 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1982.89 | 0.00 | 141.44 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 10715.40 | 1306.65 | 699.75 | 4305.74 | 0.00 | 0.00 | 0.00 | 0.00 | 122.16 | 7.84 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3340.65 | 27-JAN-10:00 | 805.43 | 268.66 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.92 |
February | 3493.04 | 23-FEB-10:00 | 805.43 | 268.66 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.99 |
March | 4539.29 | 23-MAR-10:20 | 805.43 | 268.66 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.08 |
April | 11265.88 | 30-APR-08:52 | 211.95 | 74.62 | 1514.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.30 |
May | 11711.88 | 29-MAY-09:12 | 254.35 | 89.54 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.85 |
June | 11807.51 | 25-JUN-08:12 | 254.35 | 89.54 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 1.06 | 0.00 |
July | 11869.61 | 04-JUL-09:42 | 254.35 | 89.54 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 7.84 | 0.00 |
August | 11719.76 | 27-AUG-08:32 | 254.35 | 89.54 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 13.39 | 0.00 |
September | 11457.46 | 04-SEP-09:42 | 211.95 | 74.62 | 1514.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.43 |
October | 7661.01 | 01-OCT-11:23 | 169.56 | 59.70 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 8.60 | 0.00 |
November | 4081.17 | 10-NOV-09:40 | 805.43 | 268.66 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.28 |
December | 2424.60 | 26-DEC-10:00 | 805.43 | 268.66 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.67 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 2424.60 | 169.56 | 59.70 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 11869.61 | 805.43 | 268.66 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 13.39 | 7.92 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 12810.12 | 15-JAN-13:13 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.37 |
February | 8824.02 | 28-FEB-14:10 | 1306.65 | 424.37 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.78 |
March | 7958.10 | 23-MAR-13:50 | 1306.65 | 424.37 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 5.78 | 0.00 |
April | 12325.41 | 23-APR-13:43 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 26.82 | 0.00 |
May | 10676.80 | 07-MAY-14:32 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 38.00 | 0.00 |
June | 11792.07 | 25-JUN-16:51 | 669.60 | 235.73 | 4784.12 | 0.00 | 0.00 | 0.00 | 0.00 | 75.23 | 0.00 |
July | 11711.50 | 30-JUL-15:42 | 401.76 | 141.44 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 85.15 | 0.00 |
August | 12392.38 | 27-AUG-11:52 | 334.80 | 117.87 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 54.87 | 0.00 |
September | 13156.00 | 10-SEP-13:32 | 401.76 | 141.44 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 62.24 | 0.00 |
October | 12792.99 | 09-OCT-11:23 | 267.84 | 94.29 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 2.52 | 0.00 |
November | 13014.30 | 05-NOV-13:42 | 334.80 | 117.87 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.94 |
December | 13337.48 | 25-DEC-13:52 | 334.80 | 117.87 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.36 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 7958.10 | 267.84 | 94.29 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 13337.48 | 1306.65 | 424.37 | 4784.12 | 0.00 | 0.00 | 0.00 | 0.00 | 85.15 | 36.94 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5703.78 | 29-JAN-17:13 | 127.16 | 44.77 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.64 |
February | 5421.08 | 22-FEB-16:30 | 805.38 | 268.64 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.23 |
March | 7032.58 | 18-MAR-17:08 | 169.55 | 59.69 | 1211.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.44 | 0.00 |
April | 12638.32 | 30-APR-17:31 | 0.00 | 104.46 | 1710.93 | 0.00 | 0.00 | 0.00 | 0.00 | 19.72 | 0.00 |
May | 12269.11 | 29-MAY-17:11 | 0.00 | 119.38 | 1955.35 | 0.00 | 0.00 | 0.00 | 0.00 | 33.59 | 0.00 |
June | 12569.43 | 25-JUN-16:52 | 423.88 | 149.23 | 3028.56 | 0.00 | 0.00 | 0.00 | 0.00 | 48.33 | 0.00 |
July | 12134.96 | 30-JUL-17:02 | 0.00 | 89.54 | 1466.51 | 0.00 | 0.00 | 0.00 | 0.00 | 73.51 | 0.00 |
August | 12565.95 | 06-AUG-17:42 | 0.00 | 89.54 | 1466.51 | 0.00 | 0.00 | 0.00 | 0.00 | 6.62 | 0.00 |
September | 12276.27 | 04-SEP-17:42 | 0.00 | 89.54 | 1466.51 | 0.00 | 0.00 | 0.00 | 0.00 | 18.06 | 0.00 |
October | 8896.76 | 01-OCT-16:42 | 169.55 | 59.69 | 1211.42 | 0.00 | 0.00 | 0.00 | 0.00 | 30.83 | 0.00 |
November | 6552.20 | 01-NOV-16:00 | 805.38 | 268.64 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 5.76 | 0.00 |
December | 8480.51 | 25-DEC-16:33 | 169.55 | 59.69 | 1211.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.43 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 5421.08 | 0.00 | 44.77 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 12638.32 | 805.38 | 268.64 | 3028.56 | 0.00 | 0.00 | 0.00 | 0.00 | 73.51 | 16.64 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | NATURALGAS:FACILITY [J] | NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | |
January | 0.101876E+12 | 103811.16 | 31-JAN-16:49 | 0.892491E+10 | 21657.95 | 02-JAN-07:30 |
February | 0.834705E+11 | 87198.96 | 13-FEB-07:10 | 0.818483E+10 | 17947.61 | 28-FEB-07:10 |
March | 0.104428E+12 | 107765.15 | 16-MAR-15:30 | 0.925016E+10 | 30478.06 | 27-MAR-06:19 |
April | 0.125137E+12 | 139730.38 | 14-APR-15:30 | 0.778403E+10 | 8882.01 | 03-APR-11:20 |
May | 0.146510E+12 | 145167.75 | 31-MAY-15:00 | 0.780581E+10 | 8757.42 | 01-MAY-11:30 |
June | 0.175153E+12 | 172428.96 | 28-JUN-15:09 | 0.732311E+10 | 8644.25 | 01-JUN-11:09 |
July | 0.166048E+12 | 162670.07 | 31-JUL-15:00 | 0.709788E+10 | 8567.24 | 03-JUL-11:20 |
August | 0.173279E+12 | 166544.83 | 25-AUG-15:20 | 0.748364E+10 | 8599.78 | 30-AUG-11:09 |
September | 0.149625E+12 | 155059.89 | 08-SEP-15:00 | 0.723147E+10 | 8683.21 | 28-SEP-11:20 |
October | 0.122418E+12 | 139743.75 | 02-OCT-15:30 | 0.790374E+10 | 16475.07 | 25-OCT-06:00 |
November | 0.100783E+12 | 108616.66 | 01-NOV-15:00 | 0.816186E+10 | 19319.64 | 24-NOV-07:19 |
December | 0.956837E+11 | 96925.90 | 07-DEC-07:10 | 0.102614E+11 | 37715.62 | 05-DEC-07:19 |
Annual Sum or Average | 0.154441E+13 | 0.974128E+11 | ||||
Minimum of Months | 0.834705E+11 | 87198.96 | 0.709788E+10 | 8567.24 | ||
Maximum of Months | 0.175153E+12 | 172428.96 | 0.102614E+11 | 37715.62 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [J] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [J] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 0.172963E+11 | 0.523866E+10 | 0.593559E+11 | 0.979988E+09 | 0.607902E+10 | 1312252.65 | 0.144808E+10 | 0.114765E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.155942E+11 | 0.434296E+10 | 0.537310E+11 | 0.886838E+09 | 0.443788E+10 | 1186778.30 | 0.167649E+10 | 0.279992E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.182045E+11 | 0.430202E+10 | 0.617796E+11 | 0.102611E+10 | 0.622411E+10 | 1343621.24 | 0.130447E+10 | 0.115858E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.161209E+11 | 0.368274E+10 | 0.572952E+11 | 0.943616E+09 | 0.118083E+11 | 1267813.82 | 0.138501E+09 | 0.351463E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.173017E+11 | 0.338664E+10 | 0.605677E+11 | 0.100273E+10 | 0.152551E+11 | 1327936.95 | 7993040.07 | 0.489871E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.171278E+11 | 0.313031E+10 | 0.594895E+11 | 0.987043E+09 | 0.203475E+11 | 1296568.36 | 0.00 | 0.740698E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.161157E+11 | 0.331178E+10 | 0.583622E+11 | 0.959110E+09 | 0.185968E+11 | 1299182.41 | 0.00 | 0.687011E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.180559E+11 | 0.363981E+10 | 0.617796E+11 | 0.102602E+10 | 0.187586E+11 | 1343621.24 | 0.00 | 0.700179E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.162144E+11 | 0.392215E+10 | 0.572729E+11 | 0.943438E+09 | 0.150396E+11 | 1267813.82 | 0.00 | 0.562310E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.170650E+11 | 0.457510E+10 | 0.593671E+11 | 0.979933E+09 | 0.101501E+11 | 1312252.65 | 0.345723E+09 | 0.299339E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.170417E+11 | 0.494565E+10 | 0.580818E+11 | 0.961740E+09 | 0.675610E+10 | 1278270.02 | 0.758623E+09 | 0.122366E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.168511E+11 | 0.540205E+10 | 0.583511E+11 | 0.959541E+09 | 0.521326E+10 | 1299182.41 | 0.342350E+10 | 0.548180E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.202989E+12 | 0.498799E+11 | 0.705434E+12 | 0.116561E+11 | 0.138666E+12 | 15535293.87 | 0.910338E+10 | 0.426668E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.155942E+11 | 0.313031E+10 | 0.537310E+11 | 0.886838E+09 | 0.443788E+10 | 1186778.30 | 0.00 | 0.279992E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.182045E+11 | 0.540205E+10 | 0.617796E+11 | 0.102611E+10 | 0.203475E+11 | 1343621.24 | 0.342350E+10 | 0.740698E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [J] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [J] | COGENERATION:NATURALGAS [] | HUMIDIFIER:NATURALGAS [] | |
January | 0.00 | 0.00 | 0.249451E+09 | 0.00 | 0.867546E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.361522E+09 | 0.00 | 0.782331E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.515475E+09 | 0.00 | 0.873468E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 185603.77 | 0.00 | 0.778385E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.780581E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.732311E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.709788E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.748364E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.723147E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 72437167.28 | 0.00 | 0.783131E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.148223E+09 | 0.00 | 0.801363E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.185745E+10 | 0.00 | 0.840394E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.320474E+10 | 0.00 | 0.942081E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.709788E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.185745E+10 | 0.00 | 0.873468E+10 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum} [W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | EXTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | FANS:ELECTRICITY {Maximum} [W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY {Maximum} [W] | PUMPS:ELECTRICITY {TIMESTAMP} | HEATING:ELECTRICITY {Maximum} [W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 20482.79 | 20-JAN-16:00 | 5557.43 | 01-JAN-06:10 | 45864.70 | 02-JAN-08:09 | 833.94 | 20-JAN-08:39 | 10761.89 | 27-JAN-16:00 | 0.73 | 02-JAN-08:09 | 63809.45 | 02-JAN-07:10 |
February | 20097.09 | 10-FEB-08:09 | 5557.43 | 01-FEB-06:10 | 45864.70 | 01-FEB-08:09 | 833.63 | 10-FEB-08:20 | 8145.66 | 22-FEB-16:30 | 0.73 | 08-FEB-08:09 | 49898.01 | 13-FEB-07:10 |
March | 19513.98 | 21-MAR-07:10 | 5557.43 | 01-MAR-06:10 | 45864.70 | 01-MAR-08:09 | 832.86 | 21-MAR-07:19 | 13084.57 | 16-MAR-15:30 | 0.73 | 13-MAR-07:10 | 42374.77 | 27-MAR-06:10 |
April | 18258.92 | 04-APR-07:10 | 5557.43 | 01-APR-05:10 | 45864.70 | 03-APR-07:10 | 831.20 | 04-APR-07:19 | 21603.44 | 24-APR-15:50 | 0.73 | 01-APR-05:10 | 8272.75 | 21-APR-06:10 |
May | 17272.95 | 26-MAY-08:30 | 5557.43 | 01-MAY-05:10 | 45864.70 | 01-MAY-07:10 | 829.79 | 05-MAY-07:19 | 24171.50 | 08-MAY-15:00 | 0.73 | 01-MAY-05:19 | 3936.46 | 01-MAY-06:19 |
June | 17161.59 | 27-JUN-07:10 | 5557.43 | 01-JUN-05:10 | 45864.70 | 01-JUN-07:10 | 829.75 | 27-JUN-07:19 | 26643.77 | 19-JUN-14:00 | 0.73 | 04-JUN-16:40 | 0.00 | 01-JUN-00:10 |
July | 17737.00 | 27-JUL-07:10 | 5557.43 | 01-JUL-05:10 | 45864.70 | 03-JUL-07:10 | 830.51 | 27-JUL-07:19 | 25205.21 | 31-JUL-15:00 | 0.73 | 01-JUL-05:10 | 0.00 | 01-JUL-00:10 |
August | 19830.76 | 04-AUG-07:10 | 5557.43 | 01-AUG-05:10 | 45864.70 | 01-AUG-07:10 | 833.28 | 04-AUG-07:19 | 24749.22 | 14-AUG-15:20 | 0.73 | 13-AUG-16:00 | 0.00 | 01-AUG-00:10 |
September | 18571.59 | 29-SEP-07:10 | 5557.43 | 01-SEP-05:10 | 45864.70 | 01-SEP-07:10 | 831.61 | 29-SEP-07:19 | 22822.51 | 05-SEP-15:00 | 0.73 | 01-SEP-05:10 | 0.00 | 01-SEP-00:10 |
October | 19553.29 | 27-OCT-07:10 | 5557.43 | 01-OCT-05:10 | 45864.70 | 02-OCT-07:10 | 832.91 | 27-OCT-07:19 | 19999.74 | 02-OCT-15:50 | 0.73 | 01-OCT-05:10 | 17925.54 | 26-OCT-06:10 |
November | 21377.78 | 28-NOV-16:30 | 5557.43 | 01-NOV-05:10 | 45864.70 | 01-NOV-07:10 | 833.98 | 28-NOV-16:40 | 13302.64 | 02-NOV-15:50 | 0.73 | 01-NOV-05:19 | 32875.47 | 24-NOV-07:10 |
December | 21377.78 | 01-DEC-16:30 | 5557.43 | 01-DEC-06:10 | 45864.70 | 01-DEC-08:09 | 833.98 | 01-DEC-16:40 | 8979.62 | 22-DEC-16:49 | 0.73 | 04-DEC-08:09 | 59544.95 | 07-DEC-07:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 17161.59 | 5557.43 | 45864.70 | 829.75 | 8145.66 | 0.73 | 0.00 | |||||||
Maximum of Months | 21377.78 | 5557.43 | 45864.70 | 833.98 | 26643.77 | 0.73 | 63809.45 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum} [W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 33533.39 | 31-JAN-16:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 14952.82 | 22-FEB-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 34974.45 | 16-MAR-15:39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 59622.08 | 14-APR-15:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 64253.73 | 31-MAY-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 89640.32 | 28-JUN-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 81583.90 | 19-JUL-13:39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 83790.21 | 25-AUG-15:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 74214.70 | 08-SEP-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 66207.88 | 02-OCT-13:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 38628.08 | 01-NOV-15:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 24735.15 | 22-DEC-16:19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 14952.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 89640.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 103811.16 | 31-JAN-16:49 | 17211.29 | 42072.41 | 0.00 | 828.22 | 10562.74 | 0.73 | 0.00 | 33135.76 | 0.00 |
February | 87198.96 | 13-FEB-07:10 | 7126.03 | 21098.80 | 5557.43 | 243.52 | 3274.44 | 0.73 | 49898.01 | 0.00 | 0.00 |
March | 107765.15 | 16-MAR-15:30 | 16818.70 | 42072.41 | 0.00 | 827.95 | 13084.57 | 0.73 | 0.00 | 34960.80 | 0.00 |
April | 139730.38 | 14-APR-15:30 | 16818.70 | 42072.41 | 0.00 | 827.95 | 20388.51 | 0.73 | 0.00 | 59622.08 | 0.00 |
May | 145167.75 | 31-MAY-15:00 | 16818.70 | 42072.41 | 0.00 | 827.95 | 21194.24 | 0.73 | 0.00 | 64253.73 | 0.00 |
June | 172428.96 | 28-JUN-15:09 | 16818.70 | 42072.41 | 0.00 | 827.95 | 23182.45 | 0.73 | 0.00 | 89526.72 | 0.00 |
July | 162670.07 | 31-JUL-15:00 | 16818.70 | 42072.41 | 0.00 | 827.95 | 25205.21 | 0.73 | 0.00 | 77745.07 | 0.00 |
August | 166544.83 | 25-AUG-15:20 | 16818.70 | 42072.41 | 0.00 | 827.95 | 23034.83 | 0.73 | 0.00 | 83790.21 | 0.00 |
September | 155059.89 | 08-SEP-15:00 | 16818.70 | 42072.41 | 0.00 | 827.95 | 21125.40 | 0.73 | 0.00 | 74214.70 | 0.00 |
October | 139743.75 | 02-OCT-15:30 | 16818.70 | 42072.41 | 0.00 | 827.95 | 19332.23 | 0.73 | 0.00 | 60691.74 | 0.00 |
November | 108616.66 | 01-NOV-15:00 | 17022.92 | 42072.41 | 0.00 | 828.18 | 10683.42 | 0.73 | 0.00 | 38008.99 | 0.00 |
December | 96925.90 | 07-DEC-07:10 | 7126.03 | 21098.80 | 5557.43 | 243.52 | 3354.44 | 0.73 | 59544.95 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | ||||||||||
Minimum of Months | 87198.96 | 7126.03 | 21098.80 | 0.00 | 243.52 | 3274.44 | 0.73 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 172428.96 | 17211.29 | 42072.41 | 5557.43 | 828.22 | 25205.21 | 0.73 | 59544.95 | 89526.72 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS {Maximum} [W] | HEATING:NATURALGAS {TIMESTAMP} | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS {Maximum} [W] | WATERSYSTEMS:NATURALGAS {TIMESTAMP} | COGENERATION:NATURALGAS [] | |
January | 0.00 | 0.00 | 13714.12 | 02-JAN-07:19 | 0.00 | 9052.68 | 11-JAN-12:09 | 0.00 |
February | 0.00 | 0.00 | 9972.49 | 28-FEB-07:10 | 0.00 | 9062.51 | 02-FEB-12:09 | 0.00 |
March | 0.00 | 0.00 | 22445.50 | 27-MAR-06:19 | 0.00 | 9007.35 | 02-MAR-12:09 | 0.00 |
April | 0.00 | 0.00 | 309.34 | 21-APR-06:10 | 0.00 | 8882.01 | 03-APR-11:20 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 8757.42 | 01-MAY-11:30 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 8644.25 | 01-JUN-11:09 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 8567.24 | 03-JUL-11:20 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 8599.78 | 30-AUG-11:09 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 8683.21 | 28-SEP-11:20 | 0.00 |
October | 0.00 | 0.00 | 8476.73 | 25-OCT-06:00 | 0.00 | 8819.31 | 31-OCT-11:30 | 0.00 |
November | 0.00 | 0.00 | 12233.38 | 24-NOV-07:10 | 0.00 | 8944.58 | 30-NOV-12:20 | 0.00 |
December | 0.00 | 0.00 | 31102.98 | 06-DEC-07:10 | 0.00 | 9027.03 | 29-DEC-12:20 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 8567.24 | 0.00 | ||
Maximum of Months | 0.00 | 0.00 | 31102.98 | 0.00 | 9062.51 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 26.18 | 0.00 | 26.18 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 26.18 | 0.00 | 26.18 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 26.18 | 0.00 | 26.18 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 26.20 | 0.00 | 26.20 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 26.19 | 0.00 | 26.19 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 2.17 | 26.18 | 0.00 | 26.18 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 26.20 | 0.00 | 26.20 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.17 | 17.20 | 0.00 | 17.20 | 0.00 | 17.20 | 0.00 | 17.20 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 2.00 | 27.40 | 0.67 | 27.41 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 11.33 | 27.63 | 6.33 | 27.63 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 12.67 | 27.55 | 7.50 | 27.55 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 6.50 | 27.56 | 4.00 | 27.57 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 3.17 | 27.45 | 3.00 | 27.46 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 27.40 | 0.83 | 27.40 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.17 | 17.20 | 0.00 | 17.20 | 36.50 | 27.51 | 22.33 | 27.53 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.17 | 17.20 | 0.00 | 17.20 | 12.67 | 27.63 | 7.50 | 27.63 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 7.33 | 27.73 | 7.33 | 27.73 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 13.00 | 27.81 | 12.17 | 27.82 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 13.83 | 28.11 | 10.83 | 28.16 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 17.00 | 27.94 | 13.83 | 27.98 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 10.33 | 28.02 | 8.17 | 28.07 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 8.17 | 27.75 | 7.67 | 27.76 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 2.67 | 27.53 | 2.67 | 27.53 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 72.33 | 27.90 | 62.67 | 27.92 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 17.00 | 28.11 | 13.83 | 28.16 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 5.17 | 27.81 | 5.17 | 27.81 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 27.26 | 0.17 | 27.26 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 6.17 | 27.68 | 5.67 | 27.69 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 6.50 | 27.49 | 5.67 | 27.50 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 9.00 | 27.65 | 6.00 | 27.67 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 12.33 | 27.67 | 8.83 | 27.69 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 8.33 | 27.80 | 5.50 | 27.87 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 8.17 | 27.94 | 6.67 | 27.98 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 7.50 | 27.96 | 6.83 | 27.98 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 3.50 | 27.68 | 3.50 | 27.68 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 4.17 | 27.77 | 4.17 | 27.77 |
Annual Sum or Average | 0.00 | 0.00 | 71.00 | 27.75 | 58.17 | 27.77 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 12.33 | 27.96 | 8.83 | 27.98 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 27.27 | 0.17 | 27.27 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 27.55 | 0.17 | 27.64 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 7.33 | 28.21 | 3.67 | 28.26 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 9.33 | 28.43 | 4.50 | 28.48 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 12.83 | 28.24 | 6.33 | 28.26 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 14.67 | 28.24 | 7.33 | 28.23 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 8.67 | 28.38 | 4.00 | 28.47 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 6.00 | 28.08 | 4.17 | 28.11 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 4.00 | 27.91 | 3.17 | 27.93 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 27.26 | 0.17 | 27.26 |
Annual Sum or Average | 0.00 | 0.00 | 63.50 | 28.24 | 33.67 | 28.26 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 14.67 | 28.43 | 7.33 | 28.48 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 27.30 | 0.00 | 27.30 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 27.33 | 0.33 | 27.32 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 1.50 | 27.32 | 0.33 | 27.31 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 27.33 | 0.33 | 27.32 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 3.00 | 27.53 | 3.00 | 27.53 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 5.50 | 27.65 | 5.50 | 27.65 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 10.00 | 27.74 | 9.00 | 27.76 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 14.00 | 27.66 | 12.17 | 27.68 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 9.67 | 27.68 | 8.17 | 27.74 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 8.17 | 27.58 | 7.67 | 27.59 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 2.83 | 27.44 | 2.83 | 27.44 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 53.17 | 27.65 | 48.33 | 27.67 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 14.00 | 27.74 | 12.17 | 27.76 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 15.17 | 19.65 | 15.17 | 19.65 | 6.00 | 20.97 | 6.00 | 21.92 |
February | 17.83 | 19.06 | 17.83 | 19.06 | 0.00 | 19.06 | 0.00 | 19.06 |
March | 17.00 | 18.78 | 17.00 | 18.78 | 0.00 | 18.78 | 0.00 | 18.78 |
April | 1.00 | 20.05 | 1.00 | 20.05 | 18.00 | 24.78 | 18.00 | 25.03 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 29.33 | 25.35 | 29.33 | 25.35 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 48.67 | 26.40 | 48.67 | 26.40 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 44.67 | 26.23 | 44.17 | 26.22 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 63.00 | 26.09 | 61.67 | 26.08 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 79.67 | 25.69 | 78.17 | 25.68 |
October | 4.67 | 19.69 | 4.67 | 19.69 | 54.33 | 24.85 | 53.33 | 25.24 |
November | 5.67 | 20.00 | 5.67 | 20.00 | 11.50 | 23.07 | 11.50 | 24.08 |
December | 18.67 | 18.56 | 18.67 | 18.56 | 5.33 | 19.71 | 5.33 | 20.60 |
Annual Sum or Average | 80.00 | 19.11 | 80.00 | 19.11 | 360.50 | 23.85 | 356.17 | 24.70 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.78 | 0.00 | 18.78 |
Maximum of Months | 18.67 | 20.05 | 18.67 | 20.05 | 79.67 | 26.40 | 78.17 | 26.40 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 5.00 | 27.84 | 2.67 | 27.86 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 6.67 | 27.99 | 3.50 | 27.98 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 7.17 | 28.09 | 3.17 | 28.11 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 10.33 | 28.00 | 4.67 | 28.01 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 8.00 | 27.92 | 3.67 | 28.03 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 6.33 | 27.72 | 4.17 | 27.78 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 3.50 | 27.73 | 2.83 | 27.75 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 27.42 | 0.17 | 27.42 |
Annual Sum or Average | 0.00 | 0.00 | 47.17 | 27.92 | 24.83 | 27.95 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 10.33 | 28.09 | 4.67 | 28.11 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 6.00 | 27.46 | 3.50 | 27.45 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 5.33 | 27.38 | 2.67 | 27.37 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 2.50 | 27.32 | 1.67 | 27.35 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 | 27.29 | 1.17 | 27.29 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 15.00 | 27.39 | 9.00 | 27.39 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 6.00 | 27.46 | 3.50 | 27.45 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 27.26 | 0.17 | 27.26 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 5.50 | 27.77 | 5.50 | 27.77 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 8.17 | 27.85 | 8.17 | 27.85 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 11.83 | 27.94 | 10.33 | 27.97 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 13.67 | 27.79 | 12.50 | 27.81 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 8.50 | 27.87 | 7.83 | 27.89 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 6.00 | 27.67 | 5.83 | 27.67 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 2.33 | 27.50 | 2.33 | 27.50 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 56.17 | 27.81 | 52.67 | 27.82 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 13.67 | 27.94 | 12.50 | 27.97 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 6.17 | 27.80 | 6.17 | 27.80 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 27.33 | 0.33 | 27.33 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 4.67 | 27.51 | 4.67 | 27.51 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 27.35 | 1.33 | 27.35 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 5.33 | 27.47 | 3.83 | 27.48 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 8.17 | 27.48 | 6.50 | 27.49 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 6.00 | 27.64 | 4.50 | 27.69 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 8.83 | 27.29 | 8.00 | 27.29 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 9.33 | 27.32 | 9.00 | 27.32 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 4.50 | 27.69 | 4.50 | 27.69 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 5.00 | 27.78 | 5.00 | 27.78 |
Annual Sum or Average | 0.00 | 0.00 | 59.67 | 27.51 | 53.83 | 27.52 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 9.33 | 27.80 | 9.00 | 27.80 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 27.41 | 0.17 | 27.41 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 27.64 | 0.17 | 27.64 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 6.67 | 28.02 | 3.83 | 28.04 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 8.17 | 28.24 | 4.33 | 28.27 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 9.50 | 28.20 | 4.33 | 28.22 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 10.17 | 28.23 | 4.83 | 28.24 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 7.17 | 28.25 | 3.50 | 28.33 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 5.17 | 27.91 | 3.83 | 27.94 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 3.50 | 27.78 | 2.67 | 27.81 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 27.48 | 0.17 | 27.48 |
Annual Sum or Average | 0.00 | 0.00 | 50.83 | 28.13 | 27.83 | 28.15 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 10.17 | 28.25 | 4.83 | 28.33 |
Report: ComfortReportSimple55Monthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 244.67 | 23.96 | 37.50 | 24.16 | 0.00 | 24.16 |
February | 117.67 | 23.85 | 74.67 | 24.24 | 0.00 | 24.24 |
March | 134.33 | 24.02 | 76.00 | 24.49 | 0.00 | 24.49 |
April | 100.33 | 24.03 | 40.83 | 24.57 | 0.00 | 24.57 |
May | 58.00 | 24.02 | 41.33 | 24.95 | 0.00 | 24.95 |
June | 0.00 | 0.00 | 127.50 | 25.08 | 0.00 | 25.08 |
July | 8.67 | 24.00 | 408.00 | 24.47 | 0.00 | 24.47 |
August | 0.00 | 0.00 | 453.00 | 24.40 | 0.00 | 24.40 |
September | 0.00 | 0.00 | 408.17 | 24.53 | 0.00 | 24.53 |
October | 89.17 | 24.01 | 184.50 | 24.61 | 0.00 | 24.61 |
November | 166.00 | 24.02 | 130.17 | 24.39 | 2.33 | 24.39 |
December | 362.50 | 24.01 | 2.17 | 24.02 | 0.00 | 24.02 |
Annual Sum or Average | 1281.33 | 23.99 | 1983.83 | 24.43 | 2.33 | 24.43 |
Minimum of Months | 0.00 | 0.00 | 2.17 | 24.02 | 0.00 | 24.02 |
Maximum of Months | 362.50 | 24.03 | 453.00 | 25.08 | 2.33 | 25.08 |
Report: ComfortReportSimple55Monthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 437.17 | 23.52 | 2.33 | 23.52 | 0.00 | 23.52 |
February | 389.00 | 23.29 | 0.50 | 23.29 | 0.00 | 23.29 |
March | 325.50 | 23.58 | 9.00 | 23.61 | 0.00 | 23.61 |
April | 197.50 | 23.92 | 16.67 | 24.06 | 0.00 | 24.06 |
May | 138.17 | 24.01 | 24.50 | 24.30 | 0.00 | 24.30 |
June | 13.50 | 24.01 | 102.00 | 24.91 | 0.00 | 24.91 |
July | 12.50 | 24.04 | 395.83 | 24.37 | 0.00 | 24.37 |
August | 7.83 | 24.00 | 441.33 | 24.30 | 1.67 | 24.30 |
September | 0.00 | 0.00 | 386.33 | 24.44 | 0.00 | 24.44 |
October | 198.83 | 23.85 | 124.50 | 24.13 | 0.00 | 24.13 |
November | 311.83 | 23.66 | 86.00 | 23.85 | 12.33 | 23.85 |
December | 494.67 | 23.28 | 0.00 | 23.28 | 0.00 | 23.28 |
Annual Sum or Average | 2526.50 | 23.55 | 1589.00 | 23.91 | 14.00 | 23.91 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 23.28 | 0.00 | 23.28 |
Maximum of Months | 494.67 | 24.04 | 441.33 | 24.91 | 12.33 | 24.91 |
Report: ComfortReportSimple55Monthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 486.67 | 22.95 | 12.33 | 22.88 | 12.33 | 22.81 |
February | 438.00 | 22.64 | 1.50 | 22.63 | 1.50 | 22.63 |
March | 414.17 | 23.15 | 8.17 | 23.13 | 6.00 | 23.10 |
April | 210.00 | 23.77 | 13.83 | 23.86 | 0.00 | 23.86 |
May | 148.17 | 23.98 | 27.17 | 24.24 | 0.00 | 24.24 |
June | 9.83 | 24.01 | 143.83 | 24.82 | 0.00 | 24.82 |
July | 15.50 | 24.01 | 401.83 | 24.42 | 3.50 | 24.42 |
August | 12.00 | 24.00 | 448.50 | 24.32 | 4.17 | 24.31 |
September | 7.17 | 23.79 | 383.50 | 24.43 | 1.50 | 24.42 |
October | 253.83 | 23.50 | 109.17 | 23.78 | 1.00 | 23.78 |
November | 379.50 | 23.06 | 59.33 | 23.20 | 16.33 | 23.21 |
December | 497.00 | 22.34 | 46.50 | 22.21 | 46.50 | 22.09 |
Annual Sum or Average | 2871.83 | 23.02 | 1655.67 | 23.49 | 92.83 | 23.45 |
Minimum of Months | 7.17 | 22.34 | 1.50 | 22.21 | 0.00 | 22.09 |
Maximum of Months | 497.00 | 24.01 | 448.50 | 24.82 | 46.50 | 24.82 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 501.00 | 22.17 | 83.17 | 21.90 | 83.17 | 21.69 |
February | 448.50 | 21.81 | 45.67 | 21.67 | 45.67 | 21.55 |
March | 427.33 | 22.46 | 43.17 | 22.33 | 36.17 | 22.19 |
April | 210.83 | 23.47 | 53.67 | 23.77 | 0.83 | 23.77 |
May | 111.67 | 23.81 | 87.67 | 24.48 | 0.00 | 24.48 |
June | 21.00 | 26.04 | 310.67 | 24.84 | 14.00 | 24.93 |
July | 32.17 | 26.10 | 447.67 | 24.73 | 27.50 | 24.83 |
August | 23.67 | 25.39 | 466.83 | 24.49 | 15.50 | 24.55 |
September | 50.67 | 24.93 | 409.00 | 24.58 | 29.33 | 24.67 |
October | 290.67 | 22.97 | 122.33 | 23.33 | 13.17 | 23.28 |
November | 431.17 | 22.36 | 103.00 | 22.31 | 79.83 | 22.20 |
December | 497.00 | 21.43 | 213.50 | 21.15 | 213.50 | 21.00 |
Annual Sum or Average | 3045.67 | 22.43 | 2386.33 | 23.04 | 558.67 | 22.90 |
Minimum of Months | 21.00 | 21.43 | 43.17 | 21.15 | 0.00 | 21.00 |
Maximum of Months | 501.00 | 26.10 | 466.83 | 24.84 | 213.50 | 24.93 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 447.67 | 22.59 | 55.83 | 22.36 | 52.33 | 22.17 |
February | 390.33 | 22.08 | 42.33 | 22.03 | 29.17 | 21.91 |
March | 337.17 | 22.62 | 65.00 | 22.72 | 21.83 | 22.59 |
April | 107.33 | 23.60 | 183.33 | 24.38 | 7.00 | 24.44 |
May | 64.00 | 24.58 | 238.00 | 24.79 | 16.00 | 24.92 |
June | 40.50 | 26.86 | 403.00 | 24.84 | 37.67 | 25.02 |
July | 49.50 | 26.87 | 465.83 | 24.89 | 47.67 | 25.07 |
August | 41.67 | 26.46 | 487.33 | 24.65 | 38.00 | 24.79 |
September | 57.33 | 25.72 | 433.83 | 24.69 | 42.00 | 24.85 |
October | 207.00 | 23.06 | 182.67 | 23.74 | 12.17 | 23.71 |
November | 368.67 | 22.62 | 88.50 | 22.65 | 52.67 | 22.57 |
December | 497.00 | 21.95 | 131.33 | 21.64 | 131.33 | 21.43 |
Annual Sum or Average | 2608.17 | 22.81 | 2777.00 | 23.53 | 487.83 | 23.49 |
Minimum of Months | 40.50 | 21.95 | 42.33 | 21.64 | 7.00 | 21.43 |
Maximum of Months | 497.00 | 26.87 | 487.33 | 24.89 | 131.33 | 25.07 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 260.17 | 22.53 | 166.00 | 23.08 | 38.50 | 22.92 |
February | 299.83 | 21.96 | 99.83 | 22.31 | 26.83 | 22.19 |
March | 301.17 | 22.56 | 94.67 | 22.79 | 25.50 | 22.65 |
April | 161.50 | 23.45 | 153.33 | 24.10 | 4.67 | 24.12 |
May | 125.83 | 23.74 | 128.33 | 24.40 | 1.50 | 24.42 |
June | 37.50 | 25.27 | 290.00 | 24.80 | 16.50 | 24.90 |
July | 43.33 | 25.88 | 439.83 | 24.74 | 33.00 | 24.85 |
August | 32.67 | 25.87 | 471.50 | 24.56 | 24.50 | 24.65 |
September | 61.67 | 25.64 | 427.50 | 24.73 | 42.67 | 24.88 |
October | 186.33 | 23.48 | 233.50 | 24.13 | 27.83 | 24.22 |
November | 255.83 | 22.75 | 175.67 | 23.25 | 50.33 | 23.14 |
December | 332.17 | 22.21 | 160.00 | 22.28 | 100.67 | 22.03 |
Annual Sum or Average | 2098.00 | 22.92 | 2840.17 | 23.74 | 392.50 | 23.70 |
Minimum of Months | 32.67 | 21.96 | 94.67 | 22.28 | 1.50 | 22.03 |
Maximum of Months | 332.17 | 25.88 | 471.50 | 24.80 | 100.67 | 24.90 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 401.50 | 21.91 | 96.33 | 21.80 | 75.00 | 21.61 |
February | 402.00 | 21.62 | 59.33 | 21.61 | 42.00 | 21.49 |
March | 379.83 | 22.21 | 83.50 | 22.29 | 38.17 | 22.15 |
April | 187.50 | 23.35 | 156.83 | 23.98 | 14.67 | 24.08 |
May | 135.50 | 23.93 | 193.50 | 24.47 | 18.17 | 24.61 |
June | 49.83 | 25.25 | 330.67 | 24.77 | 22.50 | 24.90 |
July | 51.33 | 25.84 | 444.00 | 24.74 | 40.17 | 24.87 |
August | 43.00 | 25.31 | 461.67 | 24.53 | 29.83 | 24.62 |
September | 69.00 | 24.85 | 413.67 | 24.58 | 40.83 | 24.69 |
October | 261.67 | 22.85 | 177.50 | 23.45 | 23.50 | 23.46 |
November | 367.33 | 22.19 | 126.17 | 22.32 | 72.17 | 22.21 |
December | 458.00 | 21.50 | 190.83 | 21.25 | 185.83 | 21.08 |
Annual Sum or Average | 2806.50 | 22.42 | 2734.00 | 23.19 | 602.83 | 23.10 |
Minimum of Months | 43.00 | 21.50 | 59.33 | 21.25 | 14.67 | 21.08 |
Maximum of Months | 458.00 | 25.84 | 461.67 | 24.77 | 185.83 | 24.90 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 22.59 | 25.00 | 22.49 | 25.00 | 22.40 |
February | 454.00 | 22.11 | 1.17 | 22.11 | 1.17 | 22.11 |
March | 486.83 | 22.63 | 15.67 | 22.57 | 15.67 | 22.51 |
April | 285.67 | 23.69 | 6.17 | 23.71 | 0.00 | 23.71 |
May | 180.00 | 23.92 | 8.50 | 23.99 | 0.00 | 23.99 |
June | 7.17 | 24.19 | 204.00 | 24.88 | 0.33 | 24.88 |
July | 4.67 | 24.84 | 445.33 | 24.58 | 2.00 | 24.59 |
August | 2.50 | 24.45 | 465.67 | 24.44 | 0.67 | 24.45 |
September | 10.67 | 26.36 | 427.83 | 24.60 | 10.67 | 24.64 |
October | 227.33 | 23.64 | 129.50 | 23.97 | 0.00 | 23.97 |
November | 377.33 | 23.21 | 67.00 | 23.38 | 20.83 | 23.42 |
December | 497.00 | 22.34 | 40.83 | 22.23 | 40.83 | 22.14 |
Annual Sum or Average | 3035.17 | 22.84 | 1836.67 | 23.43 | 117.17 | 23.40 |
Minimum of Months | 2.50 | 22.11 | 1.17 | 22.11 | 0.00 | 22.11 |
Maximum of Months | 502.00 | 26.36 | 465.67 | 24.88 | 40.83 | 24.88 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 416.17 | 23.16 | 15.50 | 23.17 | 5.17 | 23.14 |
February | 386.33 | 22.60 | 15.17 | 22.68 | 0.00 | 22.68 |
March | 357.17 | 23.00 | 31.67 | 23.13 | 4.50 | 23.10 |
April | 96.67 | 23.75 | 132.83 | 24.49 | 0.50 | 24.50 |
May | 49.17 | 24.03 | 152.00 | 24.88 | 2.17 | 24.92 |
June | 21.83 | 26.99 | 370.50 | 24.80 | 20.83 | 24.92 |
July | 29.00 | 27.00 | 466.33 | 24.83 | 29.00 | 24.95 |
August | 25.17 | 27.03 | 492.83 | 24.66 | 25.17 | 24.77 |
September | 34.17 | 26.77 | 457.33 | 24.75 | 34.17 | 24.89 |
October | 117.50 | 23.74 | 206.67 | 24.40 | 1.83 | 24.42 |
November | 276.50 | 23.52 | 95.00 | 23.77 | 22.50 | 23.80 |
December | 464.17 | 22.97 | 12.50 | 22.93 | 11.33 | 22.88 |
Annual Sum or Average | 2273.83 | 23.30 | 2448.33 | 24.01 | 157.17 | 24.06 |
Minimum of Months | 21.83 | 22.60 | 12.50 | 22.68 | 0.00 | 22.68 |
Maximum of Months | 464.17 | 27.03 | 492.83 | 24.88 | 34.17 | 24.95 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 214.33 | 23.04 | 127.83 | 23.75 | 8.50 | 23.73 |
February | 339.83 | 22.16 | 45.50 | 22.35 | 9.67 | 22.25 |
March | 361.83 | 22.56 | 60.83 | 22.65 | 20.00 | 22.49 |
April | 168.83 | 23.34 | 88.33 | 23.97 | 1.00 | 23.96 |
May | 169.50 | 23.64 | 53.00 | 24.15 | 0.00 | 24.15 |
June | 27.33 | 24.28 | 214.00 | 25.24 | 3.33 | 25.28 |
July | 36.50 | 25.00 | 443.67 | 24.83 | 31.50 | 24.85 |
August | 41.67 | 25.79 | 480.33 | 24.84 | 39.50 | 24.92 |
September | 59.67 | 26.08 | 456.33 | 25.02 | 56.00 | 25.15 |
October | 118.17 | 23.80 | 275.17 | 24.71 | 27.83 | 24.81 |
November | 163.00 | 23.19 | 213.83 | 24.05 | 24.33 | 24.05 |
December | 295.00 | 22.64 | 96.33 | 23.06 | 22.67 | 22.92 |
Annual Sum or Average | 1995.67 | 23.08 | 2555.17 | 24.07 | 244.33 | 24.08 |
Minimum of Months | 27.33 | 22.16 | 45.50 | 22.35 | 0.00 | 22.25 |
Maximum of Months | 361.83 | 26.08 | 480.33 | 25.24 | 56.00 | 25.28 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 403.50 | 22.87 | 22.50 | 22.88 | 9.67 | 22.83 |
February | 414.17 | 22.26 | 6.00 | 22.30 | 0.00 | 22.30 |
March | 406.17 | 22.74 | 34.33 | 22.85 | 6.00 | 22.82 |
April | 155.00 | 23.69 | 119.00 | 24.20 | 1.83 | 24.23 |
May | 107.17 | 23.98 | 145.33 | 24.54 | 3.83 | 24.59 |
June | 14.67 | 26.05 | 309.33 | 24.80 | 9.33 | 24.87 |
July | 21.83 | 26.60 | 461.67 | 24.73 | 19.50 | 24.82 |
August | 17.00 | 26.80 | 485.50 | 24.58 | 17.00 | 24.65 |
September | 26.17 | 26.73 | 449.50 | 24.72 | 26.17 | 24.82 |
October | 147.50 | 23.71 | 196.17 | 24.27 | 4.50 | 24.31 |
November | 277.50 | 23.39 | 118.33 | 23.73 | 19.50 | 23.77 |
December | 447.67 | 22.62 | 26.83 | 22.58 | 21.17 | 22.51 |
Annual Sum or Average | 2438.33 | 23.03 | 2374.50 | 23.80 | 138.50 | 23.84 |
Minimum of Months | 14.67 | 22.26 | 6.00 | 22.30 | 0.00 | 22.30 |
Maximum of Months | 447.67 | 26.80 | 485.50 | 24.80 | 26.17 | 24.87 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 497.00 | 22.72 | 21.17 | 22.62 | 21.17 | 22.53 |
February | 443.83 | 22.39 | 2.50 | 22.38 | 2.50 | 22.37 |
March | 402.50 | 22.91 | 19.83 | 22.89 | 10.83 | 22.83 |
April | 196.50 | 23.76 | 33.33 | 23.97 | 0.00 | 23.97 |
May | 101.50 | 23.99 | 53.17 | 24.63 | 0.00 | 24.63 |
June | 7.00 | 26.69 | 255.83 | 24.96 | 6.33 | 25.00 |
July | 8.17 | 25.83 | 446.17 | 24.64 | 6.17 | 24.67 |
August | 9.33 | 24.71 | 465.17 | 24.45 | 4.17 | 24.46 |
September | 21.17 | 25.69 | 412.67 | 24.60 | 16.17 | 24.66 |
October | 263.00 | 23.43 | 117.33 | 23.76 | 0.33 | 23.76 |
November | 402.83 | 22.91 | 61.50 | 23.06 | 27.00 | 23.10 |
December | 497.00 | 22.07 | 80.00 | 21.88 | 80.00 | 21.74 |
Annual Sum or Average | 2849.83 | 22.84 | 1968.67 | 23.47 | 174.67 | 23.43 |
Minimum of Months | 7.00 | 22.07 | 2.50 | 21.88 | 0.00 | 21.74 |
Maximum of Months | 497.00 | 26.69 | 465.17 | 24.96 | 80.00 | 25.00 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 358.50 | 22.83 | 22.33 | 22.86 | 8.00 | 22.81 |
February | 318.00 | 22.39 | 20.33 | 22.51 | 2.17 | 22.50 |
March | 278.67 | 22.87 | 53.33 | 23.14 | 6.83 | 23.09 |
April | 95.00 | 23.87 | 125.67 | 24.63 | 5.50 | 24.70 |
May | 52.00 | 24.62 | 157.33 | 25.09 | 11.17 | 25.21 |
June | 29.00 | 27.03 | 302.50 | 25.04 | 27.83 | 25.20 |
July | 36.50 | 26.94 | 389.33 | 24.98 | 36.33 | 25.14 |
August | 29.67 | 26.66 | 409.67 | 24.73 | 28.00 | 24.86 |
September | 40.33 | 26.14 | 362.17 | 24.82 | 33.67 | 24.96 |
October | 168.67 | 23.36 | 148.83 | 24.08 | 2.00 | 24.10 |
November | 294.50 | 22.98 | 63.50 | 23.20 | 23.17 | 23.22 |
December | 410.17 | 22.36 | 51.50 | 22.18 | 50.33 | 22.02 |
Annual Sum or Average | 2111.00 | 23.08 | 2106.50 | 23.87 | 235.00 | 23.92 |
Minimum of Months | 29.00 | 22.36 | 20.33 | 22.18 | 2.00 | 22.02 |
Maximum of Months | 410.17 | 27.03 | 409.67 | 25.09 | 50.33 | 25.21 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 237.83 | 23.21 | 152.67 | 23.80 | 13.50 | 23.81 |
February | 277.50 | 22.60 | 84.83 | 23.05 | 1.50 | 23.04 |
March | 264.33 | 23.05 | 83.17 | 23.38 | 6.50 | 23.34 |
April | 135.17 | 23.74 | 124.67 | 24.31 | 0.50 | 24.31 |
May | 103.67 | 23.94 | 86.67 | 24.62 | 0.00 | 24.62 |
June | 17.67 | 25.39 | 245.50 | 24.90 | 8.00 | 24.96 |
July | 25.00 | 25.99 | 440.33 | 24.70 | 19.67 | 24.78 |
August | 22.17 | 25.96 | 475.83 | 24.55 | 16.50 | 24.61 |
September | 39.67 | 26.52 | 436.17 | 24.77 | 36.83 | 24.91 |
October | 146.50 | 23.95 | 237.50 | 24.47 | 18.00 | 24.59 |
November | 208.00 | 23.35 | 182.67 | 23.95 | 23.67 | 23.98 |
December | 304.33 | 22.82 | 99.50 | 23.15 | 31.50 | 23.06 |
Annual Sum or Average | 1781.83 | 23.35 | 2649.50 | 24.13 | 176.17 | 24.17 |
Minimum of Months | 17.67 | 22.60 | 83.17 | 23.05 | 0.00 | 23.04 |
Maximum of Months | 304.33 | 26.52 | 475.83 | 24.90 | 36.83 | 24.96 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 391.17 | 22.53 | 40.00 | 22.61 | 14.50 | 22.53 |
February | 389.33 | 22.19 | 20.00 | 22.27 | 3.33 | 22.25 |
March | 355.00 | 22.73 | 58.33 | 22.90 | 10.17 | 22.86 |
April | 157.67 | 23.70 | 143.50 | 24.23 | 8.00 | 24.31 |
May | 110.33 | 24.16 | 171.67 | 24.64 | 12.50 | 24.75 |
June | 27.17 | 26.03 | 311.17 | 24.85 | 18.17 | 24.97 |
July | 33.50 | 26.22 | 448.67 | 24.72 | 28.00 | 24.83 |
August | 25.00 | 26.02 | 475.67 | 24.53 | 19.33 | 24.61 |
September | 42.00 | 25.57 | 419.00 | 24.65 | 30.17 | 24.76 |
October | 221.50 | 23.31 | 171.50 | 23.88 | 7.17 | 23.93 |
November | 336.83 | 22.79 | 100.17 | 23.14 | 24.33 | 23.17 |
December | 450.17 | 22.09 | 81.17 | 21.95 | 73.00 | 21.80 |
Annual Sum or Average | 2539.67 | 22.84 | 2440.83 | 23.63 | 248.67 | 23.65 |
Minimum of Months | 25.00 | 22.09 | 20.00 | 21.95 | 3.33 | 21.80 |
Maximum of Months | 450.17 | 26.22 | 475.67 | 24.85 | 73.00 | 24.97 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 24.22674 | 20.96904 | 0.26995 | 6.79957 |
February | 454.00000 | 24.18417 | 33.55268 | 0.32801 | 7.42026 |
March | 514.00000 | 24.29042 | 26.15891 | 0.32132 | 7.41272 |
April | 485.00000 | 24.32586 | 18.77337 | 0.31599 | 7.28386 |
May | 508.00000 | 24.34715 | 18.23898 | -0.5291 | 11.20825 |
June | 496.00000 | 24.34782 | 25.72567 | -0.4544 | 9.71161 |
July | 497.00000 | 24.42919 | 41.63692 | -0.3221 | 7.70351 |
August | 514.00000 | 24.36821 | 44.16570 | -0.3207 | 7.60066 |
September | 485.00000 | 24.45036 | 43.38613 | -0.3043 | 7.60021 |
October | 502.00000 | 24.42143 | 26.18674 | 0.39044 | 8.63582 |
November | 489.00000 | 24.37672 | 26.11547 | 0.35802 | 8.25739 |
December | 497.00000 | 24.18531 | 15.57153 | 0.21035 | 6.09258 |
Annual Sum or Average | 5943.00000 | 24.33022 | 28.34052 | 0.01880 | 7.98558 |
Minimum of Months | 454.00000 | 24.18417 | 15.57153 | -0.5291 | 6.09258 |
Maximum of Months | 514.00000 | 24.45036 | 44.16570 | 0.39044 | 11.20825 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 23.63668 | 22.94343 | 0.12142 | 5.82536 |
February | 454.00000 | 23.40582 | 36.19066 | 0.14023 | 5.75123 |
March | 514.00000 | 23.80970 | 27.89921 | 0.19880 | 6.20478 |
April | 485.00000 | 24.15905 | 19.70495 | 0.26693 | 6.70381 |
May | 508.00000 | 24.24449 | 19.10346 | -0.5785 | 12.28225 |
June | 496.00000 | 24.28877 | 26.53713 | -0.4877 | 10.31940 |
July | 497.00000 | 24.34066 | 43.62530 | -0.3564 | 8.11023 |
August | 514.00000 | 24.28248 | 46.29890 | -0.3582 | 8.03827 |
September | 485.00000 | 24.35910 | 45.11780 | -0.3495 | 8.12743 |
October | 502.00000 | 24.16564 | 27.46566 | 0.31413 | 7.54457 |
November | 489.00000 | 23.89394 | 27.88763 | 0.22639 | 6.77410 |
December | 497.00000 | 23.28898 | 17.63905 | -0.0092 | 5.51937 |
Annual Sum or Average | 5943.00000 | 23.99347 | 29.99582 | -0.0751 | 7.61923 |
Minimum of Months | 454.00000 | 23.28898 | 17.63905 | -0.5785 | 5.51937 |
Maximum of Months | 514.00000 | 24.35910 | 46.29890 | 0.31413 | 12.28225 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 22.98714 | 24.05792 | -0.0359 | 6.01274 |
February | 454.00000 | 22.68574 | 37.64006 | -0.0321 | 5.82240 |
March | 514.00000 | 23.33971 | 28.28081 | 0.08376 | 6.01975 |
April | 485.00000 | 24.05341 | 19.91952 | 0.24790 | 6.63015 |
May | 508.00000 | 24.22314 | 19.28916 | -0.5720 | 12.19712 |
June | 496.00000 | 24.31365 | 26.55148 | -0.4540 | 9.77579 |
July | 497.00000 | 24.38457 | 43.31250 | -0.3229 | 7.74317 |
August | 514.00000 | 24.29724 | 45.98646 | -0.3386 | 7.80890 |
September | 485.00000 | 24.34526 | 44.99355 | -0.3454 | 8.07612 |
October | 502.00000 | 23.88753 | 27.68645 | 0.24321 | 7.13743 |
November | 489.00000 | 23.29791 | 28.61958 | 0.07819 | 6.47649 |
December | 497.00000 | 22.34389 | 18.27896 | -0.2387 | 7.35089 |
Annual Sum or Average | 5943.00000 | 23.68683 | 30.33734 | -0.1423 | 7.60540 |
Minimum of Months | 454.00000 | 22.34389 | 18.27896 | -0.5720 | 5.82240 |
Maximum of Months | 514.00000 | 24.38457 | 45.98646 | 0.24790 | 12.19712 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 22.17188 | 25.87589 | -0.2355 | 8.13308 |
February | 454.00000 | 21.83778 | 40.71412 | -0.2364 | 7.52942 |
March | 514.00000 | 22.73561 | 30.13855 | -0.0601 | 7.14427 |
April | 485.00000 | 23.96665 | 20.27454 | 0.23612 | 7.12901 |
May | 508.00000 | 24.29191 | 19.11206 | -0.5147 | 11.57948 |
June | 496.00000 | 24.50318 | 25.96640 | -0.3137 | 8.27345 |
July | 497.00000 | 24.59103 | 42.98505 | -0.1896 | 7.01641 |
August | 514.00000 | 24.41333 | 45.77963 | -0.2493 | 7.24234 |
September | 485.00000 | 24.42984 | 45.21320 | -0.2802 | 7.88876 |
October | 502.00000 | 23.53034 | 28.82288 | 0.16129 | 7.72309 |
November | 489.00000 | 22.56398 | 30.92348 | -0.0987 | 7.71145 |
December | 497.00000 | 21.43097 | 20.10076 | -0.4701 | 11.43733 |
Annual Sum or Average | 5943.00000 | 23.38285 | 31.26199 | -0.1882 | 8.24245 |
Minimum of Months | 454.00000 | 21.43097 | 19.11206 | -0.5147 | 7.01641 |
Maximum of Months | 514.00000 | 24.59103 | 45.77963 | 0.23612 | 11.57948 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 22.76090 | 24.52868 | -0.0706 | 7.25229 |
February | 454.00000 | 22.36630 | 39.25309 | -0.0888 | 7.24690 |
March | 514.00000 | 23.17326 | 28.77345 | 0.07568 | 7.23906 |
April | 485.00000 | 24.25480 | 19.41860 | 0.37463 | 9.21688 |
May | 508.00000 | 24.44239 | 18.69016 | -0.3618 | 9.54532 |
June | 496.00000 | 24.53870 | 25.76885 | -0.1996 | 7.54305 |
July | 497.00000 | 24.64670 | 42.72215 | -0.0807 | 6.81507 |
August | 514.00000 | 24.47291 | 45.40201 | -0.1360 | 6.87482 |
September | 485.00000 | 24.47417 | 44.84230 | -0.1896 | 7.42028 |
October | 502.00000 | 23.85030 | 27.67975 | 0.28446 | 9.03404 |
November | 489.00000 | 22.98195 | 29.80977 | 0.02898 | 7.25363 |
December | 497.00000 | 21.95470 | 19.18931 | -0.3223 | 9.45298 |
Annual Sum or Average | 5943.00000 | 23.66882 | 30.44677 | -0.0578 | 7.91048 |
Minimum of Months | 454.00000 | 21.95470 | 18.69016 | -0.3618 | 6.81507 |
Maximum of Months | 514.00000 | 24.64670 | 45.40201 | 0.37463 | 9.54532 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 23.45278 | 22.25347 | 0.14763 | 8.99219 |
February | 454.00000 | 22.74498 | 37.41064 | 0.01832 | 7.92533 |
March | 514.00000 | 23.26542 | 28.26943 | 0.10117 | 7.74937 |
April | 485.00000 | 24.10880 | 19.64464 | 0.31288 | 8.51064 |
May | 508.00000 | 24.27360 | 19.04320 | -0.5026 | 11.83428 |
June | 496.00000 | 24.45373 | 26.07019 | -0.3380 | 8.68203 |
July | 497.00000 | 24.57267 | 42.98292 | -0.1896 | 7.24604 |
August | 514.00000 | 24.43314 | 45.55319 | -0.2069 | 7.16599 |
September | 485.00000 | 24.49979 | 44.65506 | -0.1868 | 7.55428 |
October | 502.00000 | 24.03560 | 26.92880 | 0.35606 | 10.34147 |
November | 489.00000 | 23.52150 | 27.88563 | 0.19899 | 8.79039 |
December | 497.00000 | 22.97197 | 17.08676 | -0.0434 | 9.63419 |
Annual Sum or Average | 5943.00000 | 23.86831 | 29.76604 | -0.0292 | 8.71069 |
Minimum of Months | 454.00000 | 22.74498 | 17.08676 | -0.5026 | 7.16599 |
Maximum of Months | 514.00000 | 24.57267 | 45.55319 | 0.35606 | 11.83428 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 22.39417 | 24.62114 | -0.1449 | 8.45171 |
February | 454.00000 | 21.91710 | 39.88864 | -0.1892 | 7.80009 |
March | 514.00000 | 22.74125 | 29.40211 | -0.0211 | 7.70482 |
April | 485.00000 | 23.96287 | 20.00107 | 0.30191 | 8.86358 |
May | 508.00000 | 24.23964 | 19.11086 | -0.4465 | 11.76158 |
June | 496.00000 | 24.46577 | 26.02304 | -0.2479 | 8.28559 |
July | 497.00000 | 24.55195 | 43.00168 | -0.1520 | 7.42157 |
August | 514.00000 | 24.38808 | 45.72403 | -0.1962 | 7.50956 |
September | 485.00000 | 24.39357 | 45.17310 | -0.2334 | 7.99716 |
October | 502.00000 | 23.54965 | 28.19827 | 0.21189 | 8.83795 |
November | 489.00000 | 22.70164 | 29.84056 | -0.0269 | 8.16494 |
December | 497.00000 | 21.72183 | 18.94352 | -0.3765 | 10.97414 |
Annual Sum or Average | 5943.00000 | 23.42915 | 30.76622 | -0.1273 | 8.65525 |
Minimum of Months | 454.00000 | 21.72183 | 18.94352 | -0.4465 | 7.42157 |
Maximum of Months | 514.00000 | 24.55195 | 45.72403 | 0.30191 | 11.76158 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 22.59039 | 25.30817 | -0.1296 | 6.27632 |
February | 454.00000 | 22.11429 | 40.21877 | -0.1640 | 6.15003 |
March | 514.00000 | 22.71117 | 30.82170 | -0.0697 | 6.24485 |
April | 485.00000 | 23.90962 | 20.37347 | 0.19715 | 6.28446 |
May | 508.00000 | 24.17345 | 19.10901 | -0.6031 | 12.99896 |
June | 496.00000 | 24.40542 | 25.79137 | -0.3997 | 8.99345 |
July | 497.00000 | 24.54228 | 41.77081 | -0.2390 | 6.95797 |
August | 514.00000 | 24.40920 | 44.41929 | -0.2716 | 7.12183 |
September | 485.00000 | 24.49093 | 43.79756 | -0.2598 | 7.28053 |
October | 502.00000 | 24.02984 | 27.92037 | 0.28751 | 7.61359 |
November | 489.00000 | 23.42715 | 29.42935 | 0.11678 | 6.48164 |
December | 497.00000 | 22.34156 | 19.17754 | -0.2288 | 6.99081 |
Annual Sum or Average | 5943.00000 | 23.60419 | 30.61737 | -0.1482 | 7.46771 |
Minimum of Months | 454.00000 | 22.11429 | 19.10901 | -0.6031 | 6.15003 |
Maximum of Months | 514.00000 | 24.54228 | 44.41929 | 0.28751 | 12.99896 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 23.34905 | 23.83754 | 0.07249 | 6.10199 |
February | 454.00000 | 22.83148 | 38.73982 | 0.02335 | 6.13880 |
March | 514.00000 | 23.39227 | 29.28829 | 0.11718 | 6.47818 |
April | 485.00000 | 24.31282 | 19.14569 | 0.36012 | 8.38049 |
May | 508.00000 | 24.42962 | 18.35842 | -0.4173 | 9.76787 |
June | 496.00000 | 24.52802 | 25.36682 | -0.2582 | 7.62165 |
July | 497.00000 | 24.66523 | 41.31948 | -0.1093 | 6.46824 |
August | 514.00000 | 24.52006 | 43.87277 | -0.1402 | 6.47902 |
September | 485.00000 | 24.57206 | 43.34822 | -0.1563 | 6.76692 |
October | 502.00000 | 24.30495 | 26.83027 | 0.40444 | 9.49789 |
November | 489.00000 | 23.83388 | 28.24390 | 0.24400 | 7.16799 |
December | 497.00000 | 23.06568 | 18.28487 | -0.0405 | 6.20585 |
Annual Sum or Average | 5943.00000 | 23.99076 | 29.66180 | 0.00705 | 7.26422 |
Minimum of Months | 454.00000 | 22.83148 | 18.28487 | -0.4173 | 6.10199 |
Maximum of Months | 514.00000 | 24.66523 | 43.87277 | 0.40444 | 9.76787 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 23.88218 | 21.20496 | 0.27270 | 8.45832 |
February | 454.00000 | 22.71360 | 37.06061 | 0.04155 | 6.87226 |
March | 514.00000 | 23.09824 | 28.21732 | 0.06933 | 7.12219 |
April | 485.00000 | 24.10933 | 18.44619 | 0.28130 | 7.66915 |
May | 508.00000 | 24.22904 | 17.46542 | -0.5805 | 13.12253 |
June | 496.00000 | 24.61780 | 24.28927 | -0.3680 | 9.10695 |
July | 497.00000 | 24.74945 | 41.36951 | -0.1800 | 6.88437 |
August | 514.00000 | 24.71082 | 43.65390 | -0.1513 | 6.73680 |
September | 485.00000 | 24.81823 | 42.68217 | -0.0923 | 6.90590 |
October | 502.00000 | 24.46773 | 25.53994 | 0.47365 | 11.70292 |
November | 489.00000 | 24.05768 | 26.70127 | 0.36241 | 9.28192 |
December | 497.00000 | 23.45821 | 15.87437 | 0.12582 | 8.31174 |
Annual Sum or Average | 5943.00000 | 24.08372 | 28.48857 | 0.01950 | 8.53239 |
Minimum of Months | 454.00000 | 22.71360 | 15.87437 | -0.5805 | 6.73680 |
Maximum of Months | 514.00000 | 24.81823 | 43.65390 | 0.47365 | 13.12253 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 23.15124 | 23.93146 | 0.03209 | 6.25488 |
February | 454.00000 | 22.42941 | 39.44551 | -0.0685 | 6.08790 |
March | 514.00000 | 23.06602 | 29.87854 | 0.04048 | 6.42482 |
April | 485.00000 | 24.18853 | 19.57960 | 0.32223 | 8.02832 |
May | 508.00000 | 24.32958 | 18.68801 | -0.4704 | 10.88394 |
June | 496.00000 | 24.48408 | 25.57880 | -0.2940 | 8.02622 |
July | 497.00000 | 24.61202 | 41.59369 | -0.1662 | 6.83170 |
August | 514.00000 | 24.47903 | 44.16530 | -0.1865 | 6.77619 |
September | 485.00000 | 24.55771 | 43.55608 | -0.1808 | 6.90817 |
October | 502.00000 | 24.22655 | 27.21903 | 0.37555 | 9.04108 |
November | 489.00000 | 23.77663 | 28.33128 | 0.23402 | 7.39798 |
December | 497.00000 | 22.79506 | 18.22463 | -0.1004 | 6.66270 |
Annual Sum or Average | 5943.00000 | 23.84962 | 29.95616 | -0.0397 | 7.45522 |
Minimum of Months | 454.00000 | 22.42941 | 18.22463 | -0.4704 | 6.08790 |
Maximum of Months | 514.00000 | 24.61202 | 44.16530 | 0.37555 | 10.88394 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 22.74181 | 25.37636 | -0.0901 | 6.32725 |
February | 454.00000 | 22.42800 | 39.54244 | -0.0871 | 5.99417 |
March | 514.00000 | 23.16806 | 29.83075 | 0.04875 | 6.29225 |
April | 485.00000 | 24.10079 | 19.99174 | 0.26039 | 6.86288 |
May | 508.00000 | 24.32393 | 18.86723 | -0.5199 | 11.19866 |
June | 496.00000 | 24.49737 | 25.82649 | -0.3454 | 8.49437 |
July | 497.00000 | 24.57565 | 43.16075 | -0.2185 | 6.97572 |
August | 514.00000 | 24.41215 | 45.96363 | -0.2678 | 7.20224 |
September | 485.00000 | 24.45998 | 45.16214 | -0.2828 | 7.66272 |
October | 502.00000 | 23.84777 | 28.57526 | 0.23876 | 7.39721 |
November | 489.00000 | 23.12669 | 30.25283 | 0.04339 | 6.61985 |
December | 497.00000 | 22.07089 | 19.72528 | -0.2970 | 8.05770 |
Annual Sum or Average | 5943.00000 | 23.65439 | 30.96692 | -0.1277 | 7.43782 |
Minimum of Months | 454.00000 | 22.07089 | 18.86723 | -0.5199 | 5.99417 |
Maximum of Months | 514.00000 | 24.57565 | 45.96363 | 0.26039 | 11.19866 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 427.00000 | 23.07635 | 23.88723 | 0.00954 | 6.44475 |
February | 385.00000 | 22.71859 | 38.26654 | 0.00155 | 6.48840 |
March | 433.00000 | 23.41447 | 28.33974 | 0.13033 | 6.92351 |
April | 410.00000 | 24.38309 | 18.82314 | 0.37512 | 8.95932 |
May | 430.00000 | 24.54635 | 17.99939 | -0.3760 | 9.64169 |
June | 418.00000 | 24.63645 | 25.10058 | -0.2308 | 7.91005 |
July | 422.00000 | 24.75155 | 42.11234 | -0.1051 | 6.87412 |
August | 433.00000 | 24.56066 | 44.71112 | -0.1626 | 7.00320 |
September | 410.00000 | 24.58762 | 44.21963 | -0.1971 | 7.45014 |
October | 427.00000 | 24.06939 | 27.09838 | 0.32256 | 8.90681 |
November | 417.00000 | 23.35343 | 29.12210 | 0.11968 | 6.84490 |
December | 422.00000 | 22.42269 | 18.26813 | -0.1992 | 7.53973 |
Annual Sum or Average | 5034.00000 | 23.88319 | 29.76525 | -0.0269 | 7.58852 |
Minimum of Months | 385.00000 | 22.42269 | 17.99939 | -0.3760 | 6.44475 |
Maximum of Months | 433.00000 | 24.75155 | 44.71112 | 0.37512 | 9.64169 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 23.86242 | 21.80987 | 0.25440 | 8.52204 |
February | 454.00000 | 23.25653 | 36.24367 | 0.14708 | 7.25687 |
March | 514.00000 | 23.64774 | 27.94976 | 0.19669 | 7.28969 |
April | 485.00000 | 24.26639 | 19.33124 | 0.33832 | 8.21172 |
May | 508.00000 | 24.35001 | 18.74938 | -0.4973 | 11.07816 |
June | 496.00000 | 24.46445 | 25.90946 | -0.3648 | 8.81166 |
July | 497.00000 | 24.57932 | 43.12917 | -0.2130 | 7.12614 |
August | 514.00000 | 24.44974 | 45.69805 | -0.2227 | 7.01739 |
September | 485.00000 | 24.54428 | 44.54290 | -0.1895 | 7.23147 |
October | 502.00000 | 24.28972 | 26.70086 | 0.41618 | 10.32580 |
November | 489.00000 | 23.94295 | 27.32374 | 0.30751 | 8.75533 |
December | 497.00000 | 23.48057 | 16.65372 | 0.09634 | 8.22515 |
Annual Sum or Average | 5943.00000 | 24.09964 | 29.46157 | 0.02037 | 8.33068 |
Minimum of Months | 454.00000 | 23.25653 | 16.65372 | -0.4973 | 7.01739 |
Maximum of Months | 514.00000 | 24.57932 | 45.69805 | 0.41618 | 11.07816 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 22.93245 | 24.17842 | -0.0087 | 6.87098 |
February | 454.00000 | 22.46724 | 38.83427 | -0.0493 | 6.38924 |
March | 514.00000 | 23.19831 | 29.16311 | 0.09066 | 6.88099 |
April | 485.00000 | 24.16478 | 19.68529 | 0.33638 | 8.53647 |
May | 508.00000 | 24.33762 | 18.79809 | -0.4367 | 10.70072 |
June | 496.00000 | 24.48965 | 25.82790 | -0.2730 | 8.14425 |
July | 497.00000 | 24.56740 | 43.13748 | -0.1733 | 7.14943 |
August | 514.00000 | 24.41944 | 45.85456 | -0.2078 | 7.18170 |
September | 485.00000 | 24.46115 | 45.06056 | -0.2282 | 7.51131 |
October | 502.00000 | 23.89389 | 27.98250 | 0.29211 | 8.52232 |
November | 489.00000 | 23.24975 | 29.27499 | 0.10996 | 7.31618 |
December | 497.00000 | 22.30094 | 18.64860 | -0.2176 | 8.09086 |
Annual Sum or Average | 5943.00000 | 23.71515 | 30.48285 | -0.0649 | 7.78514 |
Minimum of Months | 454.00000 | 22.30094 | 18.64860 | -0.4367 | 6.38924 |
Maximum of Months | 514.00000 | 24.56740 | 45.85456 | 0.33638 | 10.70072 |
Report: DXReportMonthly
For: PACU_VAV_BOT COOLING COIL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.171135E+11 | 0.431229E+10 | 278.56 | 0.169873E+11 | 0.126223E+09 | 0.00 | 1.00 | 17-JAN-14:30 | 0.00 | 01-JAN-00:10 | 46951.43 | 31-JAN-16:40 | 46951.43 | 31-JAN-16:40 | 5971.42 | 08-JAN-15:55 | 12233.14 | 31-JAN-16:40 | 0.00 |
February | 0.376141E+10 | 0.102908E+10 | 150.44 | 0.329693E+10 | 0.464487E+09 | 0.00 | 0.63 | 22-FEB-16:10 | 0.00 | 01-FEB-00:10 | 20795.11 | 22-FEB-16:10 | 20795.11 | 22-FEB-16:10 | 4069.37 | 17-FEB-12:00 | 5269.58 | 22-FEB-16:10 | 0.00 |
March | 0.162652E+11 | 0.418705E+10 | 293.43 | 0.158911E+11 | 0.374084E+09 | 0.00 | 1.00 | 15-MAR-14:40 | 0.00 | 01-MAR-00:10 | 45601.40 | 20-MAR-15:10 | 45601.40 | 20-MAR-15:10 | 2535.98 | 06-MAR-16:10 | 11665.51 | 16-MAR-15:50 | 0.00 |
April | 0.449031E+11 | 0.120783E+11 | 413.09 | 0.448254E+11 | 77737517.26 | 0.00 | 1.00 | 03-APR-09:30 | 0.00 | 01-APR-00:10 | 62685.46 | 14-APR-16:00 | 62685.46 | 14-APR-16:00 | 2376.67 | 16-APR-09:55 | 19461.78 | 14-APR-16:00 | 0.00 |
May | 0.595821E+11 | 0.167424E+11 | 466.17 | 0.595380E+11 | 44171605.75 | 0.00 | 1.00 | 01-MAY-09:50 | 0.00 | 01-MAY-00:10 | 66324.15 | 31-MAY-16:00 | 66324.15 | 31-MAY-16:00 | 2237.92 | 26-MAY-04:30 | 21900.64 | 31-MAY-16:00 | 0.00 |
June | 0.794262E+11 | 0.249251E+11 | 485.33 | 0.791999E+11 | 0.226260E+09 | 0.00 | 1.00 | 01-JUN-06:03 | 0.00 | 01-JUN-00:10 | 84815.24 | 28-JUN-06:03 | 84815.24 | 28-JUN-06:03 | 6095.17 | 30-JUN-11:03 | 29439.61 | 28-JUN-16:00 | 0.00 |
July | 0.821151E+11 | 0.242221E+11 | 492.12 | 0.760245E+11 | 0.609060E+10 | 0.00 | 1.00 | 01-JUL-08:30 | 0.00 | 01-JUL-00:10 | 121407.26 | 15-JUL-06:03 | 87069.46 | 17-JUL-06:03 | 69212.69 | 14-JUL-04:03 | 28016.55 | 19-JUL-13:00 | 0.00 |
August | 0.860394E+11 | 0.252282E+11 | 498.62 | 0.790714E+11 | 0.696808E+10 | 0.00 | 1.00 | 01-AUG-04:03 | 0.00 | 01-AUG-00:10 | 119618.46 | 01-AUG-04:03 | 86154.11 | 14-AUG-06:03 | 57450.01 | 01-AUG-04:03 | 27731.75 | 25-AUG-16:00 | 0.00 |
September | 0.748346E+11 | 0.208468E+11 | 459.27 | 0.678308E+11 | 0.700384E+10 | 0.00 | 1.00 | 01-SEP-04:03 | 0.00 | 01-SEP-00:10 | 119420.21 | 05-SEP-07:20 | 84712.07 | 18-SEP-06:03 | 68165.90 | 05-SEP-06:03 | 27546.25 | 08-SEP-04:02 | 0.00 |
October | 0.424511E+11 | 0.112964E+11 | 389.17 | 0.411307E+11 | 0.132040E+10 | 0.00 | 1.00 | 01-OCT-11:53 | 0.00 | 01-OCT-00:10 | 106702.67 | 03-OCT-04:03 | 82394.07 | 02-OCT-04:02 | 53388.86 | 03-OCT-04:03 | 24460.96 | 03-OCT-04:03 | 0.00 |
November | 0.194380E+11 | 0.484313E+10 | 285.27 | 0.182279E+11 | 0.121004E+10 | 0.00 | 1.00 | 01-NOV-10:10 | 0.00 | 01-NOV-00:10 | 53360.27 | 01-NOV-16:00 | 53360.27 | 01-NOV-16:00 | 30207.05 | 13-NOV-05:03 | 13647.94 | 01-NOV-15:10 | 0.00 |
December | 0.814301E+10 | 0.210702E+10 | 191.42 | 0.812093E+10 | 22081546.70 | 0.00 | 1.00 | 21-DEC-16:10 | 0.00 | 01-DEC-00:10 | 40963.83 | 22-DEC-16:30 | 40963.83 | 22-DEC-16:30 | 916.13 | 12-DEC-16:00 | 9540.37 | 22-DEC-16:20 | 0.00 |
Annual Sum or Average | 0.534073E+12 | 0.151818E+12 | 4402.88 | 0.510145E+12 | 0.239280E+11 | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 0.376141E+10 | 0.102908E+10 | 150.44 | 0.329693E+10 | 22081546.70 | 0.00 | 0.63 | 0.00 | 20795.11 | 20795.11 | 916.13 | 5269.58 | 0.00 | ||||||
Maximum of Months | 0.860394E+11 | 0.252282E+11 | 498.62 | 0.791999E+11 | 0.700384E+10 | 0.00 | 1.00 | 0.00 | 121407.26 | 87069.46 | 69212.69 | 29439.61 | 0.00 |
Report: DXReportMonthly
For: PACU_VAV_MID COOLING COIL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.140634E+11 | 0.358573E+10 | 276.11 | 0.139370E+11 | 0.126360E+09 | 0.00 | 1.00 | 18-JAN-15:50 | 0.00 | 01-JAN-00:10 | 38784.44 | 31-JAN-16:30 | 38784.44 | 31-JAN-16:30 | 2813.62 | 08-JAN-12:00 | 10106.82 | 31-JAN-16:30 | 0.00 |
February | 0.320158E+10 | 0.879801E+09 | 152.29 | 0.274274E+10 | 0.458841E+09 | 0.00 | 0.65 | 22-FEB-16:00 | 0.00 | 01-FEB-00:10 | 19067.48 | 22-FEB-16:00 | 19067.48 | 22-FEB-16:00 | 3532.27 | 18-FEB-11:20 | 4813.02 | 22-FEB-16:00 | 0.00 |
March | 0.138614E+11 | 0.359531E+10 | 298.89 | 0.134559E+11 | 0.405482E+09 | 0.00 | 1.00 | 15-MAR-15:00 | 0.00 | 01-MAR-00:10 | 41642.33 | 16-MAR-15:30 | 41642.33 | 16-MAR-15:30 | 2254.43 | 17-MAR-20:00 | 10790.41 | 16-MAR-15:30 | 0.00 |
April | 0.403849E+11 | 0.108767E+11 | 412.42 | 0.403314E+11 | 53446885.75 | 0.00 | 1.00 | 02-APR-15:42 | 0.00 | 01-APR-00:10 | 58974.46 | 14-APR-15:30 | 58974.46 | 14-APR-15:30 | 1980.48 | 16-APR-09:45 | 18306.78 | 14-APR-15:30 | 0.00 |
May | 0.539389E+11 | 0.151589E+11 | 463.82 | 0.539161E+11 | 22755129.27 | 0.00 | 1.00 | 01-MAY-09:50 | 0.00 | 01-MAY-00:10 | 59931.26 | 08-MAY-16:00 | 59931.26 | 08-MAY-16:00 | 1771.94 | 26-MAY-05:07 | 19369.41 | 31-MAY-16:00 | 0.00 |
June | 0.729318E+11 | 0.229140E+11 | 486.26 | 0.728068E+11 | 0.125063E+09 | 0.00 | 1.00 | 01-JUN-07:05 | 0.00 | 01-JUN-00:10 | 74438.28 | 29-JUN-06:03 | 74438.28 | 29-JUN-06:03 | 4126.30 | 17-JUN-17:38 | 27789.73 | 28-JUN-15:00 | 0.00 |
July | 0.710030E+11 | 0.209219E+11 | 484.77 | 0.665683E+11 | 0.443475E+10 | 0.00 | 1.00 | 01-JUL-08:30 | 0.00 | 01-JUL-00:10 | 110025.16 | 14-JUL-05:03 | 73832.37 | 10-JUL-04:02 | 66036.68 | 14-JUL-05:03 | 24747.23 | 14-JUL-05:03 | 0.00 |
August | 0.723462E+11 | 0.212311E+11 | 486.94 | 0.674519E+11 | 0.489434E+10 | 0.00 | 1.00 | 01-AUG-04:03 | 0.00 | 01-AUG-00:10 | 106797.69 | 01-AUG-04:03 | 78141.96 | 28-AUG-06:03 | 52725.29 | 01-AUG-04:03 | 25645.57 | 25-AUG-15:20 | 0.00 |
September | 0.606259E+11 | 0.169664E+11 | 439.43 | 0.555611E+11 | 0.506476E+10 | 0.00 | 1.00 | 01-SEP-04:03 | 0.00 | 01-SEP-00:10 | 106737.62 | 02-SEP-05:03 | 67589.19 | 18-SEP-04:03 | 60990.45 | 05-SEP-06:03 | 24907.35 | 02-SEP-05:03 | 0.00 |
October | 0.337297E+11 | 0.907106E+10 | 376.29 | 0.326818E+11 | 0.104789E+10 | 0.00 | 1.00 | 01-OCT-11:23 | 0.00 | 01-OCT-00:10 | 72055.67 | 02-OCT-04:02 | 71301.50 | 02-OCT-04:02 | 33878.49 | 03-OCT-05:03 | 20256.38 | 02-OCT-14:00 | 0.00 |
November | 0.146064E+11 | 0.371106E+10 | 278.00 | 0.136259E+11 | 0.980463E+09 | 0.00 | 1.00 | 01-NOV-10:50 | 0.00 | 01-NOV-00:10 | 45378.52 | 01-NOV-15:30 | 45378.52 | 01-NOV-15:30 | 18012.84 | 13-NOV-15:40 | 11682.54 | 01-NOV-15:20 | 0.00 |
December | 0.650936E+10 | 0.170948E+10 | 188.50 | 0.647671E+10 | 32647705.15 | 0.00 | 0.98 | 25-DEC-16:33 | 0.00 | 01-DEC-00:10 | 31745.75 | 25-DEC-16:33 | 31745.75 | 25-DEC-16:33 | 1590.43 | 12-DEC-15:00 | 7442.25 | 25-DEC-16:33 | 0.00 |
Annual Sum or Average | 0.457202E+12 | 0.130622E+12 | 4343.73 | 0.439556E+12 | 0.176468E+11 | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 0.320158E+10 | 0.879801E+09 | 152.29 | 0.274274E+10 | 22755129.27 | 0.00 | 0.65 | 0.00 | 19067.48 | 19067.48 | 1590.43 | 4813.02 | 0.00 | ||||||
Maximum of Months | 0.729318E+11 | 0.229140E+11 | 486.94 | 0.728068E+11 | 0.506476E+10 | 0.00 | 1.00 | 0.00 | 110025.16 | 78141.96 | 66036.68 | 27789.73 | 0.00 |
Report: DXReportMonthly
For: PACU_VAV_TOP COOLING COIL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.137772E+11 | 0.357843E+10 | 273.33 | 0.136036E+11 | 0.173569E+09 | 0.00 | 1.00 | 27-JAN-14:40 | 0.00 | 01-JAN-00:10 | 42988.57 | 31-JAN-16:30 | 42988.57 | 31-JAN-16:30 | 1947.59 | 22-JAN-16:25 | 11203.13 | 31-JAN-16:30 | 0.00 |
February | 0.321634E+10 | 0.891032E+09 | 149.53 | 0.266845E+10 | 0.547886E+09 | 0.00 | 0.57 | 22-FEB-16:00 | 0.00 | 01-FEB-00:10 | 19121.38 | 22-FEB-16:00 | 19121.38 | 22-FEB-16:00 | 3988.69 | 18-FEB-13:50 | 4918.99 | 22-FEB-16:00 | 0.00 |
March | 0.145189E+11 | 0.380348E+10 | 297.15 | 0.139214E+11 | 0.597509E+09 | 0.00 | 1.00 | 10-MAR-16:20 | 0.00 | 01-MAR-00:10 | 48368.81 | 16-MAR-15:40 | 48368.81 | 16-MAR-15:40 | 3338.22 | 17-MAR-10:00 | 12533.10 | 16-MAR-15:40 | 0.00 |
April | 0.448235E+11 | 0.121913E+11 | 412.06 | 0.447233E+11 | 0.100234E+09 | 0.00 | 1.00 | 01-APR-15:00 | 0.00 | 01-APR-00:10 | 71276.57 | 14-APR-15:30 | 71276.57 | 14-APR-15:30 | 2344.07 | 16-APR-10:05 | 22122.06 | 14-APR-15:30 | 0.00 |
May | 0.601765E+11 | 0.170859E+11 | 462.88 | 0.601371E+11 | 39396046.31 | 0.00 | 1.00 | 01-MAY-10:40 | 0.00 | 01-MAY-00:10 | 71463.96 | 15-MAY-15:20 | 71463.96 | 15-MAY-15:20 | 2143.12 | 26-MAY-05:07 | 22983.68 | 31-MAY-16:00 | 0.00 |
June | 0.827609E+11 | 0.262307E+11 | 489.87 | 0.825899E+11 | 0.170999E+09 | 0.00 | 1.00 | 01-JUN-07:50 | 0.00 | 01-JUN-00:10 | 86503.25 | 28-JUN-15:00 | 86503.25 | 28-JUN-15:00 | 4246.93 | 17-JUN-17:20 | 33400.02 | 28-JUN-15:00 | 0.00 |
July | 0.794066E+11 | 0.235571E+11 | 492.25 | 0.748448E+11 | 0.456175E+10 | 0.00 | 1.00 | 01-JUL-09:20 | 0.00 | 01-JUL-00:10 | 126393.79 | 14-JUL-05:03 | 87669.05 | 12-JUL-04:02 | 76020.12 | 14-JUL-05:03 | 29359.11 | 19-JUL-13:40 | 0.00 |
August | 0.796241E+11 | 0.235586E+11 | 487.41 | 0.746314E+11 | 0.499265E+10 | 0.00 | 1.00 | 01-AUG-04:03 | 0.00 | 01-AUG-00:10 | 122686.16 | 01-AUG-04:03 | 84895.32 | 14-AUG-04:02 | 64410.40 | 01-AUG-05:03 | 30701.88 | 25-AUG-15:20 | 0.00 |
September | 0.652116E+11 | 0.184177E+11 | 439.06 | 0.600968E+11 | 0.511481E+10 | 0.00 | 1.00 | 01-SEP-05:03 | 0.00 | 01-SEP-00:10 | 103545.32 | 08-SEP-05:03 | 78674.03 | 08-SEP-16:00 | 59428.40 | 05-SEP-06:03 | 26428.36 | 08-SEP-16:00 | 0.00 |
October | 0.351002E+11 | 0.956647E+10 | 371.41 | 0.339806E+11 | 0.111959E+10 | 0.00 | 1.00 | 01-OCT-11:32 | 0.00 | 01-OCT-00:10 | 82522.36 | 02-OCT-04:02 | 82522.36 | 02-OCT-04:02 | 34381.44 | 03-OCT-05:03 | 23489.40 | 02-OCT-14:00 | 0.00 |
November | 0.142315E+11 | 0.368237E+10 | 275.53 | 0.132130E+11 | 0.101851E+10 | 0.00 | 1.00 | 01-NOV-12:10 | 0.00 | 01-NOV-00:10 | 51662.07 | 01-NOV-15:30 | 51662.07 | 01-NOV-15:30 | 14556.86 | 13-NOV-15:40 | 13307.80 | 01-NOV-15:00 | 0.00 |
December | 0.623849E+10 | 0.166531E+10 | 183.36 | 0.618692E+10 | 51570690.31 | 0.00 | 0.95 | 25-DEC-16:33 | 0.00 | 01-DEC-00:10 | 35127.12 | 25-DEC-16:33 | 35127.12 | 25-DEC-16:33 | 1939.37 | 12-DEC-15:00 | 8394.49 | 25-DEC-15:52 | 0.00 |
Annual Sum or Average | 0.499086E+12 | 0.144228E+12 | 4333.83 | 0.480597E+12 | 0.184885E+11 | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 0.321634E+10 | 0.891032E+09 | 149.53 | 0.266845E+10 | 39396046.31 | 0.00 | 0.57 | 0.00 | 19121.38 | 19121.38 | 1939.37 | 4918.99 | 0.00 | ||||||
Maximum of Months | 0.827609E+11 | 0.262307E+11 | 492.25 | 0.825899E+11 | 0.511481E+10 | 0.00 | 1.00 | 0.00 | 126393.79 | 87669.05 | 76020.12 | 33400.02 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 258.53 | 0.00 | 258.53 | 229.23 | 968.55 | 0.00 | 0.00 | 0.00 |
February | 294.58 | 0.00 | 294.58 | 168.07 | 931.65 | 0.00 | 0.00 | 0.00 |
March | 391.50 | 0.00 | 391.50 | 389.98 | 853.70 | 0.00 | 0.00 | 0.00 |
April | 476.99 | 4.95 | 472.04 | 794.22 | 477.13 | 0.00 | 0.00 | 0.00 |
May | 558.36 | 44.71 | 513.65 | 1082.68 | 325.89 | 0.00 | 0.00 | 0.00 |
June | 648.85 | 117.89 | 530.96 | 1664.19 | 141.04 | 0.00 | 0.00 | 0.00 |
July | 553.35 | 57.65 | 495.70 | 1417.42 | 106.96 | 0.00 | 0.00 | 0.00 |
August | 446.65 | 11.10 | 435.56 | 1174.31 | 133.79 | 0.00 | 0.00 | 0.00 |
September | 421.41 | 0.11 | 421.30 | 981.83 | 201.62 | 0.00 | 0.00 | 0.00 |
October | 326.03 | 0.00 | 326.03 | 489.05 | 619.26 | 0.00 | 0.00 | 0.00 |
November | 271.65 | 0.00 | 271.65 | 228.28 | 892.02 | 0.00 | 0.00 | 0.00 |
December | 241.49 | 0.00 | 241.49 | 151.62 | 1157.18 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 407.86 | 19.74 | 388.12 | 733.49 | 565.93 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 241.49 | 0.00 | 241.49 | 151.62 | 106.96 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 648.85 | 117.89 | 530.96 | 1664.19 | 1157.18 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 556.77 | 349.28 | 207.49 | 737.79 | 604.43 | 0.00 | 0.00 | 0.00 |
February | 548.81 | 313.94 | 234.86 | 646.30 | 589.28 | 0.00 | 0.00 | 0.00 |
March | 686.81 | 353.30 | 333.51 | 915.47 | 536.41 | 0.00 | 0.00 | 0.00 |
April | 980.38 | 584.32 | 396.06 | 1621.10 | 305.16 | 0.00 | 0.00 | 0.00 |
May | 1016.03 | 602.29 | 413.74 | 1789.81 | 216.75 | 0.00 | 0.00 | 0.00 |
June | 1059.03 | 658.06 | 400.96 | 2134.74 | 90.25 | 0.00 | 0.00 | 0.00 |
July | 894.42 | 504.32 | 390.09 | 1820.88 | 68.18 | 0.00 | 0.00 | 0.00 |
August | 848.88 | 484.45 | 364.43 | 1717.54 | 85.70 | 0.00 | 0.00 | 0.00 |
September | 696.56 | 335.75 | 360.81 | 1357.65 | 126.86 | 0.00 | 0.00 | 0.00 |
October | 699.66 | 425.80 | 273.85 | 1106.36 | 387.68 | 0.00 | 0.00 | 0.00 |
November | 538.00 | 322.97 | 215.03 | 704.92 | 561.90 | 0.00 | 0.00 | 0.00 |
December | 490.51 | 296.18 | 194.33 | 586.67 | 718.13 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 752.25 | 436.46 | 315.79 | 1264.55 | 356.60 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 490.51 | 296.18 | 194.33 | 586.67 | 68.18 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1059.03 | 658.06 | 413.74 | 2134.74 | 718.13 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 2128.69 | 1700.12 | 428.57 | 3259.56 | 965.09 | 0.00 | 0.00 | 0.00 |
February | 1345.94 | 907.75 | 438.19 | 1865.22 | 908.76 | 0.00 | 0.00 | 0.00 |
March | 1119.92 | 576.82 | 543.10 | 1664.74 | 856.87 | 0.00 | 0.00 | 0.00 |
April | 953.35 | 385.24 | 568.10 | 1797.44 | 501.03 | 0.00 | 0.00 | 0.00 |
May | 638.84 | 105.54 | 533.30 | 1325.86 | 352.86 | 0.00 | 0.00 | 0.00 |
June | 547.04 | 42.17 | 504.87 | 1497.50 | 145.01 | 0.00 | 0.00 | 0.00 |
July | 558.97 | 57.83 | 501.14 | 1461.32 | 107.28 | 0.00 | 0.00 | 0.00 |
August | 679.68 | 187.83 | 491.85 | 1694.08 | 133.96 | 0.00 | 0.00 | 0.00 |
September | 979.36 | 417.82 | 561.54 | 2052.72 | 203.29 | 0.00 | 0.00 | 0.00 |
October | 1560.51 | 1080.10 | 480.40 | 2618.15 | 613.88 | 0.00 | 0.00 | 0.00 |
November | 1818.58 | 1392.93 | 425.64 | 2751.53 | 881.72 | 0.00 | 0.00 | 0.00 |
December | 1979.04 | 1566.68 | 412.37 | 2905.08 | 1130.01 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1192.52 | 701.60 | 490.92 | 2076.70 | 565.30 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 547.04 | 42.17 | 412.37 | 1325.86 | 107.28 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2128.69 | 1700.12 | 568.10 | 3259.56 | 1130.01 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 582.21 | 361.85 | 220.36 | 860.37 | 662.04 | 0.00 | 0.00 | 0.00 |
February | 471.64 | 228.01 | 243.63 | 569.44 | 619.51 | 0.00 | 0.00 | 0.00 |
March | 624.71 | 297.81 | 326.90 | 862.18 | 568.42 | 0.00 | 0.00 | 0.00 |
April | 959.26 | 547.19 | 412.07 | 1632.23 | 341.67 | 0.00 | 0.00 | 0.00 |
May | 961.72 | 539.24 | 422.48 | 1739.73 | 247.85 | 0.00 | 0.00 | 0.00 |
June | 1022.40 | 601.34 | 421.07 | 2092.30 | 108.09 | 0.00 | 0.00 | 0.00 |
July | 744.13 | 347.36 | 396.77 | 1574.68 | 78.54 | 0.00 | 0.00 | 0.00 |
August | 709.59 | 356.37 | 353.22 | 1494.40 | 96.33 | 0.00 | 0.00 | 0.00 |
September | 618.53 | 259.88 | 358.65 | 1240.64 | 139.21 | 0.00 | 0.00 | 0.00 |
October | 632.88 | 361.88 | 271.00 | 1039.26 | 420.66 | 0.00 | 0.00 | 0.00 |
November | 582.90 | 351.94 | 230.96 | 837.60 | 605.40 | 0.00 | 0.00 | 0.00 |
December | 469.79 | 267.49 | 202.31 | 629.75 | 778.71 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 699.11 | 377.22 | 321.89 | 1217.09 | 387.96 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 469.79 | 228.01 | 202.31 | 569.44 | 78.54 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1022.40 | 601.34 | 422.48 | 2092.30 | 778.71 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 86.17 | 0.00 | 86.17 | 73.08 | 345.13 | 0.00 | 0.00 | 0.00 |
February | 98.19 | 0.00 | 98.19 | 56.17 | 328.12 | 0.00 | 0.00 | 0.00 |
March | 130.49 | 0.00 | 130.49 | 134.89 | 287.67 | 0.00 | 0.00 | 0.00 |
April | 158.99 | 1.65 | 157.34 | 272.11 | 156.83 | 0.00 | 0.00 | 0.00 |
May | 186.11 | 14.90 | 171.21 | 369.87 | 103.82 | 0.00 | 0.00 | 0.00 |
June | 216.27 | 39.29 | 176.98 | 563.44 | 43.37 | 0.00 | 0.00 | 0.00 |
July | 184.44 | 19.22 | 165.23 | 477.31 | 35.02 | 0.00 | 0.00 | 0.00 |
August | 148.88 | 3.70 | 145.18 | 392.76 | 46.04 | 0.00 | 0.00 | 0.00 |
September | 140.46 | 0.04 | 140.43 | 325.39 | 72.62 | 0.00 | 0.00 | 0.00 |
October | 108.67 | 0.00 | 108.67 | 157.51 | 229.61 | 0.00 | 0.00 | 0.00 |
November | 90.54 | 0.00 | 90.54 | 67.86 | 336.34 | 0.00 | 0.00 | 0.00 |
December | 80.49 | 0.00 | 80.49 | 41.69 | 431.92 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 135.95 | 6.58 | 129.37 | 245.20 | 200.87 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 80.49 | 0.00 | 80.49 | 41.69 | 35.02 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 216.27 | 39.29 | 176.98 | 563.44 | 431.92 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 86.18 | 0.00 | 86.18 | 73.09 | 345.15 | 0.00 | 0.00 | 0.00 |
February | 98.20 | 0.00 | 98.20 | 56.17 | 328.14 | 0.00 | 0.00 | 0.00 |
March | 130.50 | 0.00 | 130.50 | 134.90 | 287.69 | 0.00 | 0.00 | 0.00 |
April | 159.00 | 1.65 | 157.35 | 272.13 | 156.84 | 0.00 | 0.00 | 0.00 |
May | 186.12 | 14.90 | 171.22 | 369.89 | 103.82 | 0.00 | 0.00 | 0.00 |
June | 216.29 | 39.30 | 176.99 | 563.48 | 43.37 | 0.00 | 0.00 | 0.00 |
July | 184.45 | 19.22 | 165.24 | 477.34 | 35.02 | 0.00 | 0.00 | 0.00 |
August | 148.89 | 3.70 | 145.19 | 392.79 | 46.05 | 0.00 | 0.00 | 0.00 |
September | 140.47 | 0.04 | 140.43 | 325.41 | 72.62 | 0.00 | 0.00 | 0.00 |
October | 108.68 | 0.00 | 108.68 | 157.52 | 229.63 | 0.00 | 0.00 | 0.00 |
November | 90.55 | 0.00 | 90.55 | 67.86 | 336.37 | 0.00 | 0.00 | 0.00 |
December | 80.50 | 0.00 | 80.50 | 41.69 | 431.95 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 135.96 | 6.58 | 129.37 | 245.21 | 200.88 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 80.50 | 0.00 | 80.50 | 41.69 | 35.02 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 216.29 | 39.30 | 176.99 | 563.48 | 431.95 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 86.18 | 0.00 | 86.18 | 73.09 | 345.15 | 0.00 | 0.00 | 0.00 |
February | 98.20 | 0.00 | 98.20 | 56.17 | 328.14 | 0.00 | 0.00 | 0.00 |
March | 130.50 | 0.00 | 130.50 | 134.90 | 287.69 | 0.00 | 0.00 | 0.00 |
April | 159.00 | 1.65 | 157.35 | 272.13 | 156.84 | 0.00 | 0.00 | 0.00 |
May | 186.12 | 14.90 | 171.22 | 369.89 | 103.82 | 0.00 | 0.00 | 0.00 |
June | 216.29 | 39.30 | 176.99 | 563.48 | 43.37 | 0.00 | 0.00 | 0.00 |
July | 184.45 | 19.22 | 165.24 | 477.34 | 35.02 | 0.00 | 0.00 | 0.00 |
August | 148.89 | 3.70 | 145.19 | 392.79 | 46.05 | 0.00 | 0.00 | 0.00 |
September | 140.47 | 0.04 | 140.43 | 325.41 | 72.62 | 0.00 | 0.00 | 0.00 |
October | 108.68 | 0.00 | 108.68 | 157.52 | 229.63 | 0.00 | 0.00 | 0.00 |
November | 90.55 | 0.00 | 90.55 | 67.86 | 336.37 | 0.00 | 0.00 | 0.00 |
December | 80.50 | 0.00 | 80.50 | 41.69 | 431.95 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 135.96 | 6.58 | 129.37 | 245.21 | 200.88 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 80.50 | 0.00 | 80.50 | 41.69 | 35.02 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 216.29 | 39.30 | 176.99 | 563.48 | 431.95 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 535.59 | 335.99 | 199.60 | 699.03 | 635.00 | 0.00 | 0.00 | 0.00 |
February | 527.93 | 302.00 | 225.93 | 620.60 | 612.06 | 0.00 | 0.00 | 0.00 |
March | 660.68 | 339.86 | 320.82 | 887.68 | 535.67 | 0.00 | 0.00 | 0.00 |
April | 943.08 | 562.09 | 381.00 | 1574.45 | 301.56 | 0.00 | 0.00 | 0.00 |
May | 977.37 | 579.38 | 398.00 | 1739.75 | 209.98 | 0.00 | 0.00 | 0.00 |
June | 1018.74 | 633.03 | 385.71 | 2070.10 | 86.52 | 0.00 | 0.00 | 0.00 |
July | 860.39 | 485.14 | 375.25 | 1759.70 | 70.04 | 0.00 | 0.00 | 0.00 |
August | 816.58 | 466.02 | 350.56 | 1656.11 | 92.34 | 0.00 | 0.00 | 0.00 |
September | 670.06 | 322.98 | 347.08 | 1303.99 | 137.98 | 0.00 | 0.00 | 0.00 |
October | 673.04 | 409.61 | 263.43 | 1055.24 | 421.49 | 0.00 | 0.00 | 0.00 |
November | 517.53 | 310.68 | 206.85 | 659.21 | 617.48 | 0.00 | 0.00 | 0.00 |
December | 471.85 | 284.92 | 186.94 | 536.67 | 784.87 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 723.63 | 419.85 | 303.78 | 1216.35 | 374.45 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 471.85 | 284.92 | 186.94 | 536.67 | 70.04 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1018.74 | 633.03 | 398.00 | 2070.10 | 784.87 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 21.18 | 13.28 | 7.89 | 27.64 | 25.11 | 0.00 | 0.00 | 0.00 |
February | 20.87 | 11.94 | 8.93 | 24.54 | 24.20 | 0.00 | 0.00 | 0.00 |
March | 26.12 | 13.44 | 12.69 | 35.10 | 21.18 | 0.00 | 0.00 | 0.00 |
April | 37.29 | 22.22 | 15.06 | 62.25 | 11.92 | 0.00 | 0.00 | 0.00 |
May | 38.64 | 22.91 | 15.74 | 68.79 | 8.30 | 0.00 | 0.00 | 0.00 |
June | 40.28 | 25.03 | 15.25 | 81.85 | 3.42 | 0.00 | 0.00 | 0.00 |
July | 34.02 | 19.18 | 14.84 | 69.58 | 2.77 | 0.00 | 0.00 | 0.00 |
August | 32.29 | 18.43 | 13.86 | 65.48 | 3.65 | 0.00 | 0.00 | 0.00 |
September | 26.49 | 12.77 | 13.72 | 51.56 | 5.46 | 0.00 | 0.00 | 0.00 |
October | 26.61 | 16.20 | 10.42 | 41.72 | 16.67 | 0.00 | 0.00 | 0.00 |
November | 20.46 | 12.28 | 8.18 | 26.06 | 24.41 | 0.00 | 0.00 | 0.00 |
December | 18.66 | 11.27 | 7.39 | 21.22 | 31.03 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 28.61 | 16.60 | 12.01 | 48.09 | 14.81 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 18.66 | 11.27 | 7.39 | 21.22 | 2.77 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 40.28 | 25.03 | 15.74 | 81.85 | 31.03 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 709.58 | 566.73 | 142.86 | 1086.05 | 359.72 | 0.00 | 0.00 | 0.00 |
February | 448.66 | 302.59 | 146.07 | 628.16 | 326.15 | 0.00 | 0.00 | 0.00 |
March | 373.32 | 192.28 | 181.04 | 563.89 | 294.34 | 0.00 | 0.00 | 0.00 |
April | 317.79 | 128.42 | 189.37 | 606.71 | 169.51 | 0.00 | 0.00 | 0.00 |
May | 212.95 | 35.18 | 177.77 | 449.31 | 114.59 | 0.00 | 0.00 | 0.00 |
June | 182.35 | 14.06 | 168.29 | 502.54 | 45.81 | 0.00 | 0.00 | 0.00 |
July | 186.33 | 19.28 | 167.05 | 487.43 | 36.64 | 0.00 | 0.00 | 0.00 |
August | 226.57 | 62.61 | 163.96 | 560.86 | 49.48 | 0.00 | 0.00 | 0.00 |
September | 326.46 | 139.28 | 187.19 | 678.94 | 78.16 | 0.00 | 0.00 | 0.00 |
October | 520.18 | 360.05 | 160.14 | 869.27 | 232.63 | 0.00 | 0.00 | 0.00 |
November | 606.21 | 464.33 | 141.88 | 913.19 | 336.81 | 0.00 | 0.00 | 0.00 |
December | 659.70 | 522.24 | 137.46 | 963.69 | 428.25 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 397.52 | 233.87 | 163.65 | 693.22 | 205.55 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 182.35 | 14.06 | 137.46 | 449.31 | 36.64 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 709.58 | 566.73 | 189.37 | 1086.05 | 428.25 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 709.58 | 566.73 | 142.86 | 1086.05 | 359.72 | 0.00 | 0.00 | 0.00 |
February | 448.66 | 302.59 | 146.07 | 628.16 | 326.15 | 0.00 | 0.00 | 0.00 |
March | 373.32 | 192.28 | 181.04 | 563.89 | 294.34 | 0.00 | 0.00 | 0.00 |
April | 317.79 | 128.42 | 189.37 | 606.71 | 169.51 | 0.00 | 0.00 | 0.00 |
May | 212.95 | 35.18 | 177.77 | 449.31 | 114.59 | 0.00 | 0.00 | 0.00 |
June | 182.35 | 14.06 | 168.29 | 502.54 | 45.81 | 0.00 | 0.00 | 0.00 |
July | 186.33 | 19.28 | 167.05 | 487.43 | 36.64 | 0.00 | 0.00 | 0.00 |
August | 226.57 | 62.61 | 163.96 | 560.86 | 49.48 | 0.00 | 0.00 | 0.00 |
September | 326.46 | 139.28 | 187.19 | 678.94 | 78.16 | 0.00 | 0.00 | 0.00 |
October | 520.18 | 360.05 | 160.14 | 869.27 | 232.63 | 0.00 | 0.00 | 0.00 |
November | 606.21 | 464.33 | 141.88 | 913.19 | 336.81 | 0.00 | 0.00 | 0.00 |
December | 659.70 | 522.24 | 137.46 | 963.69 | 428.25 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 397.52 | 233.87 | 163.65 | 693.22 | 205.55 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 182.35 | 14.06 | 137.46 | 449.31 | 36.64 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 709.58 | 566.73 | 189.37 | 1086.05 | 428.25 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 709.54 | 566.69 | 142.85 | 1085.98 | 359.70 | 0.00 | 0.00 | 0.00 |
February | 448.63 | 302.57 | 146.06 | 628.12 | 326.13 | 0.00 | 0.00 | 0.00 |
March | 373.29 | 192.27 | 181.03 | 563.85 | 294.32 | 0.00 | 0.00 | 0.00 |
April | 317.77 | 128.41 | 189.36 | 606.67 | 169.50 | 0.00 | 0.00 | 0.00 |
May | 212.94 | 35.18 | 177.76 | 449.28 | 114.58 | 0.00 | 0.00 | 0.00 |
June | 182.34 | 14.06 | 168.28 | 502.51 | 45.80 | 0.00 | 0.00 | 0.00 |
July | 186.32 | 19.28 | 167.04 | 487.40 | 36.64 | 0.00 | 0.00 | 0.00 |
August | 226.55 | 62.61 | 163.95 | 560.82 | 49.48 | 0.00 | 0.00 | 0.00 |
September | 326.44 | 139.27 | 187.17 | 678.89 | 78.15 | 0.00 | 0.00 | 0.00 |
October | 520.15 | 360.02 | 160.13 | 869.22 | 232.61 | 0.00 | 0.00 | 0.00 |
November | 606.17 | 464.30 | 141.88 | 913.14 | 336.79 | 0.00 | 0.00 | 0.00 |
December | 659.66 | 522.21 | 137.45 | 963.63 | 428.23 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 397.49 | 233.86 | 163.64 | 693.18 | 205.54 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 182.34 | 14.06 | 137.45 | 449.28 | 36.64 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 709.54 | 566.69 | 189.36 | 1085.98 | 428.23 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 560.06 | 348.08 | 211.97 | 820.85 | 698.86 | 0.00 | 0.00 | 0.00 |
February | 453.70 | 219.34 | 234.37 | 549.07 | 641.70 | 0.00 | 0.00 | 0.00 |
March | 600.94 | 286.48 | 314.46 | 837.60 | 568.70 | 0.00 | 0.00 | 0.00 |
April | 922.77 | 526.37 | 396.39 | 1583.13 | 340.55 | 0.00 | 0.00 | 0.00 |
May | 925.13 | 518.72 | 406.41 | 1688.81 | 242.75 | 0.00 | 0.00 | 0.00 |
June | 983.51 | 578.46 | 405.05 | 2027.35 | 105.13 | 0.00 | 0.00 | 0.00 |
July | 715.82 | 334.14 | 381.68 | 1520.77 | 80.07 | 0.00 | 0.00 | 0.00 |
August | 682.60 | 342.81 | 339.79 | 1438.66 | 102.07 | 0.00 | 0.00 | 0.00 |
September | 595.00 | 249.99 | 345.01 | 1190.00 | 150.82 | 0.00 | 0.00 | 0.00 |
October | 608.81 | 348.11 | 260.69 | 990.01 | 459.22 | 0.00 | 0.00 | 0.00 |
November | 560.73 | 338.55 | 222.18 | 790.38 | 669.86 | 0.00 | 0.00 | 0.00 |
December | 451.92 | 257.31 | 194.61 | 588.98 | 848.91 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 672.51 | 362.87 | 309.64 | 1171.39 | 408.15 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 451.92 | 219.34 | 194.61 | 549.07 | 80.07 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 983.51 | 578.46 | 406.41 | 2027.35 | 848.91 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 22.14 | 13.76 | 8.38 | 32.46 | 27.63 | 0.00 | 0.00 | 0.00 |
February | 17.94 | 8.67 | 9.27 | 21.71 | 25.37 | 0.00 | 0.00 | 0.00 |
March | 23.76 | 11.33 | 12.43 | 33.12 | 22.49 | 0.00 | 0.00 | 0.00 |
April | 36.49 | 20.81 | 15.67 | 62.60 | 13.46 | 0.00 | 0.00 | 0.00 |
May | 36.58 | 20.51 | 16.07 | 66.77 | 9.60 | 0.00 | 0.00 | 0.00 |
June | 38.89 | 22.87 | 16.02 | 80.16 | 4.16 | 0.00 | 0.00 | 0.00 |
July | 28.30 | 13.21 | 15.09 | 60.13 | 3.17 | 0.00 | 0.00 | 0.00 |
August | 26.99 | 13.55 | 13.43 | 56.88 | 4.04 | 0.00 | 0.00 | 0.00 |
September | 23.53 | 9.88 | 13.64 | 47.05 | 5.96 | 0.00 | 0.00 | 0.00 |
October | 24.07 | 13.76 | 10.31 | 39.14 | 18.16 | 0.00 | 0.00 | 0.00 |
November | 22.17 | 13.39 | 8.78 | 31.25 | 26.49 | 0.00 | 0.00 | 0.00 |
December | 17.87 | 10.17 | 7.69 | 23.29 | 33.56 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 26.59 | 14.35 | 12.24 | 46.32 | 16.14 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 17.87 | 8.67 | 7.69 | 21.71 | 3.17 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 38.89 | 22.87 | 16.07 | 80.16 | 33.56 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 258.53 | 0.00 | 258.53 | 211.04 | 1048.50 | 0.00 | 0.00 | 0.00 |
February | 294.58 | 0.00 | 294.58 | 153.70 | 1016.67 | 0.00 | 0.00 | 0.00 |
March | 391.50 | 0.00 | 391.50 | 375.51 | 910.35 | 0.00 | 0.00 | 0.00 |
April | 476.99 | 4.95 | 472.04 | 796.26 | 497.58 | 0.00 | 0.00 | 0.00 |
May | 558.36 | 44.71 | 513.65 | 1087.76 | 333.77 | 0.00 | 0.00 | 0.00 |
June | 648.85 | 117.89 | 530.96 | 1676.69 | 141.39 | 0.00 | 0.00 | 0.00 |
July | 553.35 | 57.65 | 495.70 | 1431.25 | 107.21 | 0.00 | 0.00 | 0.00 |
August | 446.65 | 11.10 | 435.56 | 1184.07 | 136.24 | 0.00 | 0.00 | 0.00 |
September | 421.41 | 0.11 | 421.30 | 987.52 | 208.05 | 0.00 | 0.00 | 0.00 |
October | 326.03 | 0.00 | 326.03 | 481.59 | 663.46 | 0.00 | 0.00 | 0.00 |
November | 271.65 | 0.00 | 271.65 | 211.39 | 971.05 | 0.00 | 0.00 | 0.00 |
December | 241.49 | 0.00 | 241.49 | 131.68 | 1259.54 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 407.86 | 19.74 | 388.12 | 730.00 | 606.14 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 241.49 | 0.00 | 241.49 | 131.68 | 107.21 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 648.85 | 117.89 | 530.96 | 1676.69 | 1259.54 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_2_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 556.77 | 349.28 | 207.49 | 722.89 | 647.20 | 0.00 | 0.00 | 0.00 |
February | 548.81 | 313.94 | 234.86 | 634.51 | 636.44 | 0.00 | 0.00 | 0.00 |
March | 686.81 | 353.30 | 333.51 | 905.28 | 566.51 | 0.00 | 0.00 | 0.00 |
April | 980.38 | 584.32 | 396.06 | 1624.57 | 314.99 | 0.00 | 0.00 | 0.00 |
May | 1016.03 | 602.29 | 413.74 | 1796.31 | 221.91 | 0.00 | 0.00 | 0.00 |
June | 1059.03 | 658.06 | 400.96 | 2145.69 | 90.77 | 0.00 | 0.00 | 0.00 |
July | 894.42 | 504.32 | 390.09 | 1831.87 | 68.65 | 0.00 | 0.00 | 0.00 |
August | 848.88 | 484.45 | 364.43 | 1726.43 | 87.56 | 0.00 | 0.00 | 0.00 |
September | 696.56 | 335.75 | 360.81 | 1363.07 | 130.56 | 0.00 | 0.00 | 0.00 |
October | 699.66 | 425.80 | 273.85 | 1102.19 | 410.66 | 0.00 | 0.00 | 0.00 |
November | 538.00 | 322.97 | 215.03 | 691.25 | 605.08 | 0.00 | 0.00 | 0.00 |
December | 490.51 | 296.18 | 194.33 | 565.84 | 775.15 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 752.25 | 436.46 | 315.79 | 1262.14 | 378.54 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 490.51 | 296.18 | 194.33 | 565.84 | 68.65 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1059.03 | 658.06 | 413.74 | 2145.69 | 775.15 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 2128.69 | 1700.12 | 428.57 | 3243.92 | 1028.57 | 0.00 | 0.00 | 0.00 |
February | 1345.94 | 907.75 | 438.19 | 1849.21 | 982.04 | 0.00 | 0.00 | 0.00 |
March | 1119.92 | 576.82 | 543.10 | 1652.50 | 908.67 | 0.00 | 0.00 | 0.00 |
April | 953.35 | 385.24 | 568.10 | 1801.63 | 522.50 | 0.00 | 0.00 | 0.00 |
May | 638.84 | 105.54 | 533.30 | 1331.81 | 365.13 | 0.00 | 0.00 | 0.00 |
June | 547.04 | 42.17 | 504.87 | 1509.29 | 147.45 | 0.00 | 0.00 | 0.00 |
July | 558.97 | 57.83 | 501.14 | 1474.12 | 109.02 | 0.00 | 0.00 | 0.00 |
August | 679.68 | 187.83 | 491.85 | 1704.47 | 137.81 | 0.00 | 0.00 | 0.00 |
September | 979.36 | 417.82 | 561.54 | 2060.47 | 210.23 | 0.00 | 0.00 | 0.00 |
October | 1560.51 | 1080.10 | 480.40 | 2613.61 | 650.56 | 0.00 | 0.00 | 0.00 |
November | 1818.58 | 1392.93 | 425.64 | 2735.54 | 944.98 | 0.00 | 0.00 | 0.00 |
December | 1979.04 | 1566.68 | 412.37 | 2881.91 | 1213.88 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1192.52 | 701.60 | 490.92 | 2073.86 | 600.21 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 547.04 | 42.17 | 412.37 | 1331.81 | 109.02 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2128.69 | 1700.12 | 568.10 | 3243.92 | 1213.88 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_4_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 582.21 | 361.85 | 220.36 | 850.20 | 712.47 | 0.00 | 0.00 | 0.00 |
February | 471.64 | 228.01 | 243.63 | 560.37 | 672.66 | 0.00 | 0.00 | 0.00 |
March | 624.71 | 297.81 | 326.90 | 852.96 | 605.00 | 0.00 | 0.00 | 0.00 |
April | 959.26 | 547.19 | 412.07 | 1634.16 | 355.79 | 0.00 | 0.00 | 0.00 |
May | 961.72 | 539.24 | 422.48 | 1744.59 | 255.83 | 0.00 | 0.00 | 0.00 |
June | 1022.40 | 601.34 | 421.07 | 2101.79 | 109.58 | 0.00 | 0.00 | 0.00 |
July | 744.13 | 347.36 | 396.77 | 1583.51 | 79.62 | 0.00 | 0.00 | 0.00 |
August | 709.59 | 356.37 | 353.22 | 1501.23 | 98.77 | 0.00 | 0.00 | 0.00 |
September | 618.53 | 259.88 | 358.65 | 1244.57 | 143.92 | 0.00 | 0.00 | 0.00 |
October | 632.88 | 361.88 | 271.00 | 1035.03 | 449.12 | 0.00 | 0.00 | 0.00 |
November | 582.90 | 351.94 | 230.96 | 827.32 | 655.14 | 0.00 | 0.00 | 0.00 |
December | 469.79 | 267.49 | 202.31 | 617.20 | 842.65 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 699.11 | 377.22 | 321.89 | 1215.49 | 414.01 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 469.79 | 228.01 | 202.31 | 560.37 | 79.62 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1022.40 | 601.34 | 422.48 | 2101.79 | 842.65 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.692434E+09 | 0.00 | 0.692434E+09 | 0.613980E+09 | 0.259416E+10 |
February | 0.712656E+09 | 0.00 | 0.712656E+09 | 0.406605E+09 | 0.225386E+10 |
March | 0.104860E+10 | 0.00 | 0.104860E+10 | 0.104452E+10 | 0.228656E+10 |
April | 0.123635E+10 | 12830113.86 | 0.122352E+10 | 0.205862E+10 | 0.123672E+10 |
May | 0.149552E+10 | 0.119747E+09 | 0.137577E+10 | 0.289984E+10 | 0.872853E+09 |
June | 0.168183E+10 | 0.305571E+09 | 0.137626E+10 | 0.431357E+10 | 0.365585E+09 |
July | 0.148209E+10 | 0.154404E+09 | 0.132768E+10 | 0.379640E+10 | 0.286478E+09 |
August | 0.119631E+10 | 29719197.80 | 0.116659E+10 | 0.314527E+10 | 0.358341E+09 |
September | 0.109229E+10 | 291589.31 | 0.109200E+10 | 0.254490E+10 | 0.522611E+09 |
October | 0.873252E+09 | 0.00 | 0.873252E+09 | 0.130988E+10 | 0.165862E+10 |
November | 0.704109E+09 | 0.00 | 0.704109E+09 | 0.591709E+09 | 0.231213E+10 |
December | 0.646797E+09 | 0.00 | 0.646797E+09 | 0.406108E+09 | 0.309938E+10 |
Annual Sum or Average | 0.128622E+11 | 0.622563E+09 | 0.122397E+11 | 0.231314E+11 | 0.178473E+11 |
Minimum of Months | 0.646797E+09 | 0.00 | 0.646797E+09 | 0.406108E+09 | 0.286478E+09 |
Maximum of Months | 0.168183E+10 | 0.305571E+09 | 0.137626E+10 | 0.431357E+10 | 0.309938E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.149126E+10 | 0.935504E+09 | 0.555752E+09 | 0.197610E+10 | 0.161890E+10 |
February | 0.132767E+10 | 0.759488E+09 | 0.568185E+09 | 0.156353E+10 | 0.142557E+10 |
March | 0.183954E+10 | 0.946272E+09 | 0.893270E+09 | 0.245201E+10 | 0.143671E+10 |
April | 0.254114E+10 | 0.151455E+10 | 0.102659E+10 | 0.420189E+10 | 0.790969E+09 |
May | 0.272132E+10 | 0.161317E+10 | 0.110815E+10 | 0.479382E+10 | 0.580552E+09 |
June | 0.274500E+10 | 0.170570E+10 | 0.103930E+10 | 0.553326E+10 | 0.233928E+09 |
July | 0.239560E+10 | 0.135078E+10 | 0.104482E+10 | 0.487705E+10 | 0.182620E+09 |
August | 0.227364E+10 | 0.129756E+10 | 0.976078E+09 | 0.460025E+10 | 0.229534E+09 |
September | 0.180549E+10 | 0.870276E+09 | 0.935215E+09 | 0.351902E+10 | 0.328818E+09 |
October | 0.187396E+10 | 0.114048E+10 | 0.733484E+09 | 0.296328E+10 | 0.103835E+10 |
November | 0.139449E+10 | 0.837126E+09 | 0.557360E+09 | 0.182716E+10 | 0.145644E+10 |
December | 0.131379E+10 | 0.793301E+09 | 0.520486E+09 | 0.157134E+10 | 0.192345E+10 |
Annual Sum or Average | 0.237229E+11 | 0.137642E+11 | 0.995870E+10 | 0.398787E+11 | 0.112458E+11 |
Minimum of Months | 0.131379E+10 | 0.759488E+09 | 0.520486E+09 | 0.156353E+10 | 0.182620E+09 |
Maximum of Months | 0.274500E+10 | 0.170570E+10 | 0.110815E+10 | 0.553326E+10 | 0.192345E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.570147E+10 | 0.455360E+10 | 0.114787E+10 | 0.873041E+10 | 0.258490E+10 |
February | 0.325610E+10 | 0.219602E+10 | 0.106007E+10 | 0.451235E+10 | 0.219848E+10 |
March | 0.299960E+10 | 0.154495E+10 | 0.145465E+10 | 0.445885E+10 | 0.229505E+10 |
April | 0.247108E+10 | 0.998553E+09 | 0.147253E+10 | 0.465896E+10 | 0.129866E+10 |
May | 0.171108E+10 | 0.282688E+09 | 0.142839E+10 | 0.355118E+10 | 0.945111E+09 |
June | 0.141792E+10 | 0.109302E+09 | 0.130862E+10 | 0.388153E+10 | 0.375875E+09 |
July | 0.149716E+10 | 0.154892E+09 | 0.134227E+10 | 0.391401E+10 | 0.287335E+09 |
August | 0.182047E+10 | 0.503085E+09 | 0.131738E+10 | 0.453743E+10 | 0.358787E+09 |
September | 0.253850E+10 | 0.108298E+10 | 0.145552E+10 | 0.532064E+10 | 0.526926E+09 |
October | 0.417966E+10 | 0.289294E+10 | 0.128671E+10 | 0.701244E+10 | 0.164422E+10 |
November | 0.471375E+10 | 0.361049E+10 | 0.110326E+10 | 0.713196E+10 | 0.228542E+10 |
December | 0.530067E+10 | 0.419619E+10 | 0.110448E+10 | 0.778096E+10 | 0.302663E+10 |
Annual Sum or Average | 0.376074E+11 | 0.221257E+11 | 0.154818E+11 | 0.654907E+11 | 0.178274E+11 |
Minimum of Months | 0.141792E+10 | 0.109302E+09 | 0.106007E+10 | 0.355118E+10 | 0.287335E+09 |
Maximum of Months | 0.570147E+10 | 0.455360E+10 | 0.147253E+10 | 0.873041E+10 | 0.302663E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.155938E+10 | 0.969179E+09 | 0.590203E+09 | 0.230441E+10 | 0.177320E+10 |
February | 0.114100E+10 | 0.551603E+09 | 0.589398E+09 | 0.137759E+10 | 0.149872E+10 |
March | 0.167322E+10 | 0.797647E+09 | 0.875569E+09 | 0.230927E+10 | 0.152246E+10 |
April | 0.248640E+10 | 0.141831E+10 | 0.106808E+10 | 0.423073E+10 | 0.885610E+09 |
May | 0.257587E+10 | 0.144429E+10 | 0.113158E+10 | 0.465970E+10 | 0.663833E+09 |
June | 0.265007E+10 | 0.155867E+10 | 0.109141E+10 | 0.542325E+10 | 0.280160E+09 |
July | 0.199308E+10 | 0.930359E+09 | 0.106272E+10 | 0.421762E+10 | 0.210361E+09 |
August | 0.190058E+10 | 0.954507E+09 | 0.946071E+09 | 0.400261E+10 | 0.258008E+09 |
September | 0.160323E+10 | 0.673609E+09 | 0.929617E+09 | 0.321575E+10 | 0.360822E+09 |
October | 0.169511E+10 | 0.969260E+09 | 0.725854E+09 | 0.278355E+10 | 0.112670E+10 |
November | 0.151088E+10 | 0.912223E+09 | 0.598656E+09 | 0.217105E+10 | 0.156921E+10 |
December | 0.125830E+10 | 0.716434E+09 | 0.541863E+09 | 0.168673E+10 | 0.208568E+10 |
Annual Sum or Average | 0.220471E+11 | 0.118961E+11 | 0.101510E+11 | 0.383822E+11 | 0.122348E+11 |
Minimum of Months | 0.114100E+10 | 0.551603E+09 | 0.541863E+09 | 0.137759E+10 | 0.210361E+09 |
Maximum of Months | 0.265007E+10 | 0.155867E+10 | 0.113158E+10 | 0.542325E+10 | 0.208568E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.230800E+09 | 0.00 | 0.230800E+09 | 0.195742E+09 | 0.924401E+09 |
February | 0.237541E+09 | 0.00 | 0.237541E+09 | 0.135875E+09 | 0.793785E+09 |
March | 0.349515E+09 | 0.00 | 0.349515E+09 | 0.361286E+09 | 0.770489E+09 |
April | 0.412096E+09 | 4276502.28 | 0.407820E+09 | 0.705306E+09 | 0.406511E+09 |
May | 0.498483E+09 | 39913884.74 | 0.458569E+09 | 0.990650E+09 | 0.278059E+09 |
June | 0.560582E+09 | 0.101852E+09 | 0.458730E+09 | 0.146044E+10 | 0.112421E+09 |
July | 0.494006E+09 | 51465646.98 | 0.442540E+09 | 0.127843E+10 | 93797463.86 |
August | 0.398752E+09 | 9905930.57 | 0.388846E+09 | 0.105197E+10 | 0.123326E+09 |
September | 0.364081E+09 | 97191.84 | 0.363983E+09 | 0.843402E+09 | 0.188224E+09 |
October | 0.291070E+09 | 0.00 | 0.291070E+09 | 0.421874E+09 | 0.614990E+09 |
November | 0.234692E+09 | 0.00 | 0.234692E+09 | 0.175882E+09 | 0.871803E+09 |
December | 0.215589E+09 | 0.00 | 0.215589E+09 | 0.111668E+09 | 0.115685E+10 |
Annual Sum or Average | 0.428721E+10 | 0.207511E+09 | 0.407970E+10 | 0.773253E+10 | 0.633466E+10 |
Minimum of Months | 0.215589E+09 | 0.00 | 0.215589E+09 | 0.111668E+09 | 93797463.86 |
Maximum of Months | 0.560582E+09 | 0.101852E+09 | 0.458730E+09 | 0.146044E+10 | 0.115685E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.230815E+09 | 0.00 | 0.230815E+09 | 0.195754E+09 | 0.924459E+09 |
February | 0.237556E+09 | 0.00 | 0.237556E+09 | 0.135884E+09 | 0.793835E+09 |
March | 0.349538E+09 | 0.00 | 0.349538E+09 | 0.361309E+09 | 0.770538E+09 |
April | 0.412122E+09 | 4276772.55 | 0.407846E+09 | 0.705351E+09 | 0.406537E+09 |
May | 0.498514E+09 | 39916407.23 | 0.458598E+09 | 0.990713E+09 | 0.278076E+09 |
June | 0.560618E+09 | 0.101858E+09 | 0.458759E+09 | 0.146053E+10 | 0.112428E+09 |
July | 0.494037E+09 | 51468899.52 | 0.442568E+09 | 0.127851E+10 | 93803391.70 |
August | 0.398777E+09 | 9906556.61 | 0.388871E+09 | 0.105204E+10 | 0.123334E+09 |
September | 0.364104E+09 | 97197.98 | 0.364006E+09 | 0.843456E+09 | 0.188236E+09 |
October | 0.291089E+09 | 0.00 | 0.291089E+09 | 0.421900E+09 | 0.615029E+09 |
November | 0.234707E+09 | 0.00 | 0.234707E+09 | 0.175893E+09 | 0.871858E+09 |
December | 0.215603E+09 | 0.00 | 0.215603E+09 | 0.111675E+09 | 0.115693E+10 |
Annual Sum or Average | 0.428748E+10 | 0.207524E+09 | 0.407995E+10 | 0.773302E+10 | 0.633506E+10 |
Minimum of Months | 0.215603E+09 | 0.00 | 0.215603E+09 | 0.111675E+09 | 93803391.70 |
Maximum of Months | 0.560618E+09 | 0.101858E+09 | 0.458759E+09 | 0.146053E+10 | 0.115693E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.230815E+09 | 0.00 | 0.230815E+09 | 0.195754E+09 | 0.924459E+09 |
February | 0.237556E+09 | 0.00 | 0.237556E+09 | 0.135884E+09 | 0.793835E+09 |
March | 0.349538E+09 | 0.00 | 0.349538E+09 | 0.361309E+09 | 0.770538E+09 |
April | 0.412122E+09 | 4276772.55 | 0.407846E+09 | 0.705351E+09 | 0.406537E+09 |
May | 0.498514E+09 | 39916407.23 | 0.458598E+09 | 0.990713E+09 | 0.278076E+09 |
June | 0.560618E+09 | 0.101858E+09 | 0.458759E+09 | 0.146053E+10 | 0.112428E+09 |
July | 0.494037E+09 | 51468899.52 | 0.442568E+09 | 0.127851E+10 | 93803391.70 |
August | 0.398777E+09 | 9906556.61 | 0.388871E+09 | 0.105204E+10 | 0.123334E+09 |
September | 0.364104E+09 | 97197.98 | 0.364006E+09 | 0.843456E+09 | 0.188236E+09 |
October | 0.291089E+09 | 0.00 | 0.291089E+09 | 0.421900E+09 | 0.615029E+09 |
November | 0.234707E+09 | 0.00 | 0.234707E+09 | 0.175893E+09 | 0.871858E+09 |
December | 0.215603E+09 | 0.00 | 0.215603E+09 | 0.111675E+09 | 0.115693E+10 |
Annual Sum or Average | 0.428748E+10 | 0.207524E+09 | 0.407995E+10 | 0.773302E+10 | 0.633506E+10 |
Minimum of Months | 0.215603E+09 | 0.00 | 0.215603E+09 | 0.111675E+09 | 93803391.70 |
Maximum of Months | 0.560618E+09 | 0.101858E+09 | 0.458759E+09 | 0.146053E+10 | 0.115693E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.143453E+10 | 0.899913E+09 | 0.534612E+09 | 0.187228E+10 | 0.170078E+10 |
February | 0.127716E+10 | 0.730593E+09 | 0.546571E+09 | 0.150136E+10 | 0.148069E+10 |
March | 0.176956E+10 | 0.910271E+09 | 0.859290E+09 | 0.237757E+10 | 0.143473E+10 |
April | 0.244447E+10 | 0.145693E+10 | 0.987542E+09 | 0.408097E+10 | 0.781636E+09 |
May | 0.261780E+10 | 0.155180E+10 | 0.106600E+10 | 0.465974E+10 | 0.562423E+09 |
June | 0.264057E+10 | 0.164081E+10 | 0.999767E+09 | 0.536570E+10 | 0.224248E+09 |
July | 0.230447E+10 | 0.129939E+10 | 0.100508E+10 | 0.471319E+10 | 0.187590E+09 |
August | 0.218714E+10 | 0.124819E+10 | 0.938948E+09 | 0.443573E+10 | 0.247312E+09 |
September | 0.173681E+10 | 0.837167E+09 | 0.899639E+09 | 0.337995E+10 | 0.357636E+09 |
October | 0.180267E+10 | 0.109709E+10 | 0.705582E+09 | 0.282634E+10 | 0.112892E+10 |
November | 0.134144E+10 | 0.805278E+09 | 0.536158E+09 | 0.170866E+10 | 0.160052E+10 |
December | 0.126381E+10 | 0.763120E+09 | 0.500687E+09 | 0.143743E+10 | 0.210218E+10 |
Annual Sum or Average | 0.228204E+11 | 0.132405E+11 | 0.957987E+10 | 0.383589E+11 | 0.118087E+11 |
Minimum of Months | 0.126381E+10 | 0.730593E+09 | 0.500687E+09 | 0.143743E+10 | 0.187590E+09 |
Maximum of Months | 0.264057E+10 | 0.164081E+10 | 0.106600E+10 | 0.536570E+10 | 0.210218E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 56719828.13 | 35581757.50 | 21138070.63 | 74028178.61 | 67247186.24 |
February | 50497914.78 | 28886985.18 | 21610929.59 | 59362286.05 | 58545233.20 |
March | 69966834.45 | 35991292.48 | 33975541.97 | 94006872.32 | 56727776.57 |
April | 96652142.40 | 57605634.02 | 39046508.38 | 0.161358E+09 | 30905169.73 |
May | 0.103505E+09 | 61356715.86 | 42148610.46 | 0.184242E+09 | 22237681.95 |
June | 0.104406E+09 | 64876028.27 | 39529895.41 | 0.212155E+09 | 8866581.40 |
July | 91116650.19 | 51376699.48 | 39739950.72 | 0.186355E+09 | 7417121.53 |
August | 86477595.18 | 49352440.62 | 37125154.56 | 0.175385E+09 | 9778491.54 |
September | 68671718.82 | 33100816.36 | 35570902.45 | 0.133640E+09 | 14140603.92 |
October | 71275881.63 | 43377800.09 | 27898081.54 | 0.111751E+09 | 44636491.67 |
November | 53039175.95 | 31839969.78 | 21199206.18 | 67559004.95 | 63283148.23 |
December | 49969795.95 | 30173082.91 | 19796713.04 | 56834538.07 | 83118427.58 |
Annual Sum or Average | 0.902299E+09 | 0.523519E+09 | 0.378780E+09 | 0.151668E+10 | 0.466904E+09 |
Minimum of Months | 49969795.95 | 28886985.18 | 19796713.04 | 56834538.07 | 7417121.53 |
Maximum of Months | 0.104406E+09 | 64876028.27 | 42148610.46 | 0.212155E+09 | 83118427.58 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.190055E+10 | 0.151792E+10 | 0.382634E+09 | 0.290888E+10 | 0.963482E+09 |
February | 0.108540E+10 | 0.732031E+09 | 0.353368E+09 | 0.151963E+10 | 0.789031E+09 |
March | 0.999896E+09 | 0.514999E+09 | 0.484897E+09 | 0.151031E+10 | 0.788358E+09 |
April | 0.823716E+09 | 0.332862E+09 | 0.490854E+09 | 0.157258E+10 | 0.439366E+09 |
May | 0.570375E+09 | 94232517.90 | 0.476142E+09 | 0.120343E+10 | 0.306912E+09 |
June | 0.472651E+09 | 36435293.28 | 0.436216E+09 | 0.130259E+10 | 0.118734E+09 |
July | 0.499066E+09 | 51632483.83 | 0.447433E+09 | 0.130553E+10 | 98139821.59 |
August | 0.606839E+09 | 0.167701E+09 | 0.439139E+09 | 0.150220E+10 | 0.132531E+09 |
September | 0.846192E+09 | 0.361007E+09 | 0.485186E+09 | 0.175981E+10 | 0.202579E+09 |
October | 0.139326E+10 | 0.964345E+09 | 0.428917E+09 | 0.232826E+10 | 0.623068E+09 |
November | 0.157130E+10 | 0.120353E+10 | 0.367765E+09 | 0.236700E+10 | 0.873024E+09 |
December | 0.176695E+10 | 0.139878E+10 | 0.368171E+09 | 0.258115E+10 | 0.114703E+10 |
Annual Sum or Average | 0.125362E+11 | 0.737547E+10 | 0.516072E+10 | 0.218614E+11 | 0.648226E+10 |
Minimum of Months | 0.472651E+09 | 36435293.28 | 0.353368E+09 | 0.120343E+10 | 98139821.59 |
Maximum of Months | 0.190055E+10 | 0.151792E+10 | 0.490854E+09 | 0.290888E+10 | 0.114703E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.190055E+10 | 0.151792E+10 | 0.382634E+09 | 0.290888E+10 | 0.963482E+09 |
February | 0.108540E+10 | 0.732031E+09 | 0.353368E+09 | 0.151963E+10 | 0.789031E+09 |
March | 0.999896E+09 | 0.514999E+09 | 0.484897E+09 | 0.151031E+10 | 0.788358E+09 |
April | 0.823716E+09 | 0.332862E+09 | 0.490854E+09 | 0.157258E+10 | 0.439366E+09 |
May | 0.570375E+09 | 94232517.90 | 0.476142E+09 | 0.120343E+10 | 0.306912E+09 |
June | 0.472651E+09 | 36435293.28 | 0.436216E+09 | 0.130259E+10 | 0.118734E+09 |
July | 0.499066E+09 | 51632483.83 | 0.447433E+09 | 0.130553E+10 | 98139821.59 |
August | 0.606839E+09 | 0.167701E+09 | 0.439139E+09 | 0.150220E+10 | 0.132531E+09 |
September | 0.846192E+09 | 0.361007E+09 | 0.485186E+09 | 0.175981E+10 | 0.202579E+09 |
October | 0.139326E+10 | 0.964345E+09 | 0.428917E+09 | 0.232826E+10 | 0.623068E+09 |
November | 0.157130E+10 | 0.120353E+10 | 0.367765E+09 | 0.236700E+10 | 0.873024E+09 |
December | 0.176695E+10 | 0.139878E+10 | 0.368171E+09 | 0.258115E+10 | 0.114703E+10 |
Annual Sum or Average | 0.125362E+11 | 0.737547E+10 | 0.516072E+10 | 0.218614E+11 | 0.648226E+10 |
Minimum of Months | 0.472651E+09 | 36435293.28 | 0.353368E+09 | 0.120343E+10 | 98139821.59 |
Maximum of Months | 0.190055E+10 | 0.151792E+10 | 0.490854E+09 | 0.290888E+10 | 0.114703E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.190043E+10 | 0.151782E+10 | 0.382610E+09 | 0.290870E+10 | 0.963421E+09 |
February | 0.108533E+10 | 0.731985E+09 | 0.353346E+09 | 0.151954E+10 | 0.788981E+09 |
March | 0.999833E+09 | 0.514966E+09 | 0.484867E+09 | 0.151021E+10 | 0.788309E+09 |
April | 0.823664E+09 | 0.332841E+09 | 0.490823E+09 | 0.157248E+10 | 0.439338E+09 |
May | 0.570339E+09 | 94226562.93 | 0.476112E+09 | 0.120335E+10 | 0.306892E+09 |
June | 0.472621E+09 | 36432990.78 | 0.436188E+09 | 0.130250E+10 | 0.118726E+09 |
July | 0.499034E+09 | 51629220.94 | 0.447405E+09 | 0.130545E+10 | 98133619.71 |
August | 0.606801E+09 | 0.167690E+09 | 0.439111E+09 | 0.150210E+10 | 0.132523E+09 |
September | 0.846139E+09 | 0.360984E+09 | 0.485155E+09 | 0.175970E+10 | 0.202566E+09 |
October | 0.139317E+10 | 0.964285E+09 | 0.428890E+09 | 0.232811E+10 | 0.623029E+09 |
November | 0.157120E+10 | 0.120346E+10 | 0.367742E+09 | 0.236685E+10 | 0.872969E+09 |
December | 0.176684E+10 | 0.139869E+10 | 0.368147E+09 | 0.258099E+10 | 0.114696E+10 |
Annual Sum or Average | 0.125354E+11 | 0.737501E+10 | 0.516040E+10 | 0.218600E+11 | 0.648185E+10 |
Minimum of Months | 0.472621E+09 | 36432990.78 | 0.353346E+09 | 0.120335E+10 | 98133619.71 |
Maximum of Months | 0.190043E+10 | 0.151782E+10 | 0.490823E+09 | 0.290870E+10 | 0.114696E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.150006E+10 | 0.932307E+09 | 0.567752E+09 | 0.219858E+10 | 0.187182E+10 |
February | 0.109759E+10 | 0.530618E+09 | 0.566977E+09 | 0.132830E+10 | 0.155241E+10 |
March | 0.160956E+10 | 0.767301E+09 | 0.842262E+09 | 0.224343E+10 | 0.152320E+10 |
April | 0.239181E+10 | 0.136435E+10 | 0.102745E+10 | 0.410348E+10 | 0.882700E+09 |
May | 0.247788E+10 | 0.138934E+10 | 0.108854E+10 | 0.452330E+10 | 0.650189E+09 |
June | 0.254926E+10 | 0.149937E+10 | 0.104989E+10 | 0.525489E+10 | 0.272488E+09 |
July | 0.191726E+10 | 0.894964E+09 | 0.102229E+10 | 0.407322E+10 | 0.214454E+09 |
August | 0.182828E+10 | 0.918193E+09 | 0.910084E+09 | 0.385331E+10 | 0.273382E+09 |
September | 0.154224E+10 | 0.647981E+09 | 0.894254E+09 | 0.308448E+10 | 0.390933E+09 |
October | 0.163063E+10 | 0.932385E+09 | 0.698243E+09 | 0.265164E+10 | 0.122998E+10 |
November | 0.145340E+10 | 0.877518E+09 | 0.575884E+09 | 0.204866E+10 | 0.173628E+10 |
December | 0.121043E+10 | 0.689177E+09 | 0.521250E+09 | 0.157752E+10 | 0.227371E+10 |
Annual Sum or Average | 0.212084E+11 | 0.114435E+11 | 0.976488E+10 | 0.369408E+11 | 0.128716E+11 |
Minimum of Months | 0.109759E+10 | 0.530618E+09 | 0.521250E+09 | 0.132830E+10 | 0.214454E+09 |
Maximum of Months | 0.254926E+10 | 0.149937E+10 | 0.108854E+10 | 0.525489E+10 | 0.227371E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 59310802.78 | 36862441.60 | 22448361.18 | 86929467.11 | 74010070.15 |
February | 43397800.01 | 20980073.75 | 22417726.27 | 52519682.99 | 61380934.29 |
March | 63640511.41 | 30338286.32 | 33302225.09 | 88702854.59 | 60225935.18 |
April | 94569701.97 | 53945157.66 | 40624544.31 | 0.162247E+09 | 34901137.16 |
May | 97972901.83 | 54933205.91 | 43039695.92 | 0.178847E+09 | 25707847.35 |
June | 0.100795E+09 | 59283427.48 | 41511653.45 | 0.207773E+09 | 10773925.20 |
July | 75806424.69 | 35385937.36 | 40420487.33 | 0.161051E+09 | 8479311.64 |
August | 72288202.72 | 36304390.75 | 35983811.97 | 0.152356E+09 | 10809272.89 |
September | 60978432.03 | 25620519.82 | 35357912.21 | 0.121957E+09 | 15457098.02 |
October | 64473385.56 | 36865549.88 | 27607835.68 | 0.104843E+09 | 48632175.94 |
November | 57466037.47 | 34696164.32 | 22769873.15 | 81001766.18 | 68650963.68 |
December | 47859091.44 | 27249360.81 | 20609730.63 | 62373690.87 | 89900478.02 |
Annual Sum or Average | 0.838558E+09 | 0.452465E+09 | 0.386094E+09 | 0.146060E+10 | 0.508929E+09 |
Minimum of Months | 43397800.01 | 20980073.75 | 20609730.63 | 52519682.99 | 8479311.64 |
Maximum of Months | 0.100795E+09 | 59283427.48 | 43039695.92 | 0.207773E+09 | 89900478.02 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.692434E+09 | 0.00 | 0.692434E+09 | 0.565250E+09 | 0.280830E+10 |
February | 0.712656E+09 | 0.00 | 0.712656E+09 | 0.371834E+09 | 0.245953E+10 |
March | 0.104860E+10 | 0.00 | 0.104860E+10 | 0.100577E+10 | 0.243828E+10 |
April | 0.123635E+10 | 12830113.86 | 0.122352E+10 | 0.206391E+10 | 0.128973E+10 |
May | 0.149552E+10 | 0.119747E+09 | 0.137577E+10 | 0.291347E+10 | 0.893974E+09 |
June | 0.168183E+10 | 0.305571E+09 | 0.137626E+10 | 0.434598E+10 | 0.366484E+09 |
July | 0.148209E+10 | 0.154404E+09 | 0.132768E+10 | 0.383346E+10 | 0.287164E+09 |
August | 0.119631E+10 | 29719197.80 | 0.116659E+10 | 0.317142E+10 | 0.364902E+09 |
September | 0.109229E+10 | 291589.31 | 0.109200E+10 | 0.255965E+10 | 0.539277E+09 |
October | 0.873252E+09 | 0.00 | 0.873252E+09 | 0.128990E+10 | 0.177700E+10 |
November | 0.704109E+09 | 0.00 | 0.704109E+09 | 0.547914E+09 | 0.251695E+10 |
December | 0.646797E+09 | 0.00 | 0.646797E+09 | 0.352687E+09 | 0.337356E+10 |
Annual Sum or Average | 0.128622E+11 | 0.622563E+09 | 0.122397E+11 | 0.230212E+11 | 0.191152E+11 |
Minimum of Months | 0.646797E+09 | 0.00 | 0.646797E+09 | 0.352687E+09 | 0.287164E+09 |
Maximum of Months | 0.168183E+10 | 0.305571E+09 | 0.137626E+10 | 0.434598E+10 | 0.337356E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_2_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.149126E+10 | 0.935504E+09 | 0.555752E+09 | 0.193620E+10 | 0.173346E+10 |
February | 0.132767E+10 | 0.759488E+09 | 0.568185E+09 | 0.153502E+10 | 0.153967E+10 |
March | 0.183954E+10 | 0.946272E+09 | 0.893270E+09 | 0.242471E+10 | 0.151733E+10 |
April | 0.254114E+10 | 0.151455E+10 | 0.102659E+10 | 0.421088E+10 | 0.816446E+09 |
May | 0.272132E+10 | 0.161317E+10 | 0.110815E+10 | 0.481124E+10 | 0.594373E+09 |
June | 0.274500E+10 | 0.170570E+10 | 0.103930E+10 | 0.556164E+10 | 0.235276E+09 |
July | 0.239560E+10 | 0.135078E+10 | 0.104482E+10 | 0.490648E+10 | 0.183884E+09 |
August | 0.227364E+10 | 0.129756E+10 | 0.976078E+09 | 0.462407E+10 | 0.234508E+09 |
September | 0.180549E+10 | 0.870276E+09 | 0.935215E+09 | 0.353308E+10 | 0.338404E+09 |
October | 0.187396E+10 | 0.114048E+10 | 0.733484E+09 | 0.295212E+10 | 0.109992E+10 |
November | 0.139449E+10 | 0.837126E+09 | 0.557360E+09 | 0.179173E+10 | 0.156837E+10 |
December | 0.131379E+10 | 0.793301E+09 | 0.520486E+09 | 0.151553E+10 | 0.207616E+10 |
Annual Sum or Average | 0.237229E+11 | 0.137642E+11 | 0.995870E+10 | 0.398027E+11 | 0.119378E+11 |
Minimum of Months | 0.131379E+10 | 0.759488E+09 | 0.520486E+09 | 0.151553E+10 | 0.183884E+09 |
Maximum of Months | 0.274500E+10 | 0.170570E+10 | 0.110815E+10 | 0.556164E+10 | 0.207616E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.570147E+10 | 0.455360E+10 | 0.114787E+10 | 0.868850E+10 | 0.275493E+10 |
February | 0.325610E+10 | 0.219602E+10 | 0.106007E+10 | 0.447361E+10 | 0.237575E+10 |
March | 0.299960E+10 | 0.154495E+10 | 0.145465E+10 | 0.442606E+10 | 0.243377E+10 |
April | 0.247108E+10 | 0.998553E+09 | 0.147253E+10 | 0.466984E+10 | 0.135432E+10 |
May | 0.171108E+10 | 0.282688E+09 | 0.142839E+10 | 0.356713E+10 | 0.977961E+09 |
June | 0.141792E+10 | 0.109302E+09 | 0.130862E+10 | 0.391207E+10 | 0.382184E+09 |
July | 0.149716E+10 | 0.154892E+09 | 0.134227E+10 | 0.394827E+10 | 0.292012E+09 |
August | 0.182047E+10 | 0.503085E+09 | 0.131738E+10 | 0.456524E+10 | 0.369107E+09 |
September | 0.253850E+10 | 0.108298E+10 | 0.145552E+10 | 0.534073E+10 | 0.544926E+09 |
October | 0.417966E+10 | 0.289294E+10 | 0.128671E+10 | 0.700030E+10 | 0.174247E+10 |
November | 0.471375E+10 | 0.361049E+10 | 0.110326E+10 | 0.709053E+10 | 0.244939E+10 |
December | 0.530067E+10 | 0.419619E+10 | 0.110448E+10 | 0.771892E+10 | 0.325126E+10 |
Annual Sum or Average | 0.376074E+11 | 0.221257E+11 | 0.154818E+11 | 0.654012E+11 | 0.189281E+11 |
Minimum of Months | 0.141792E+10 | 0.109302E+09 | 0.106007E+10 | 0.356713E+10 | 0.292012E+09 |
Maximum of Months | 0.570147E+10 | 0.455360E+10 | 0.147253E+10 | 0.868850E+10 | 0.325126E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_4_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.155938E+10 | 0.969179E+09 | 0.590203E+09 | 0.227718E+10 | 0.190827E+10 |
February | 0.114100E+10 | 0.551603E+09 | 0.589398E+09 | 0.135564E+10 | 0.162730E+10 |
March | 0.167322E+10 | 0.797647E+09 | 0.875569E+09 | 0.228457E+10 | 0.162044E+10 |
April | 0.248640E+10 | 0.141831E+10 | 0.106808E+10 | 0.423574E+10 | 0.922219E+09 |
May | 0.257587E+10 | 0.144429E+10 | 0.113158E+10 | 0.467270E+10 | 0.685224E+09 |
June | 0.265007E+10 | 0.155867E+10 | 0.109141E+10 | 0.544785E+10 | 0.284036E+09 |
July | 0.199308E+10 | 0.930359E+09 | 0.106272E+10 | 0.424128E+10 | 0.213249E+09 |
August | 0.190058E+10 | 0.954507E+09 | 0.946071E+09 | 0.402090E+10 | 0.264541E+09 |
September | 0.160323E+10 | 0.673609E+09 | 0.929617E+09 | 0.322593E+10 | 0.373034E+09 |
October | 0.169511E+10 | 0.969260E+09 | 0.725854E+09 | 0.277224E+10 | 0.120291E+10 |
November | 0.151088E+10 | 0.912223E+09 | 0.598656E+09 | 0.214440E+10 | 0.169813E+10 |
December | 0.125830E+10 | 0.716434E+09 | 0.541863E+09 | 0.165312E+10 | 0.225695E+10 |
Annual Sum or Average | 0.220471E+11 | 0.118961E+11 | 0.101510E+11 | 0.383315E+11 | 0.130563E+11 |
Minimum of Months | 0.114100E+10 | 0.551603E+09 | 0.541863E+09 | 0.135564E+10 | 0.213249E+09 |
Maximum of Months | 0.265007E+10 | 0.155867E+10 | 0.113158E+10 | 0.544785E+10 | 0.225695E+10 |
Report: WindowZoneSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 229.23 | 968.55 | 258.53 | 0.00 | 258.53 | 0.00 | 0.00 |
February | 168.07 | 931.65 | 294.58 | 0.00 | 294.58 | 0.00 | 0.00 |
March | 389.98 | 853.70 | 391.50 | 0.00 | 391.50 | 0.00 | 0.00 |
April | 794.22 | 477.13 | 476.99 | 4.95 | 472.04 | 0.00 | 0.00 |
May | 1082.68 | 325.89 | 558.36 | 44.71 | 513.65 | 0.00 | 0.00 |
June | 1664.19 | 141.04 | 648.85 | 117.89 | 530.96 | 0.00 | 0.00 |
July | 1417.42 | 106.96 | 553.35 | 57.65 | 495.70 | 0.00 | 0.00 |
August | 1174.31 | 133.79 | 446.65 | 11.10 | 435.56 | 0.00 | 0.00 |
September | 981.83 | 201.62 | 421.41 | 0.11 | 421.30 | 0.00 | 0.00 |
October | 489.05 | 619.26 | 326.03 | 0.00 | 326.03 | 0.00 | 0.00 |
November | 228.28 | 892.02 | 271.65 | 0.00 | 271.65 | 0.00 | 0.00 |
December | 151.62 | 1157.18 | 241.49 | 0.00 | 241.49 | 0.00 | 0.00 |
Annual Sum or Average | 733.49 | 565.93 | 407.86 | 19.74 | 388.12 | 0.00 | 0.00 |
Minimum of Months | 151.62 | 106.96 | 241.49 | 0.00 | 241.49 | 0.00 | 0.00 |
Maximum of Months | 1664.19 | 1157.18 | 648.85 | 117.89 | 530.96 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 737.79 | 604.43 | 556.77 | 349.28 | 207.49 | 0.00 | 0.00 |
February | 646.30 | 589.28 | 548.81 | 313.94 | 234.86 | 0.00 | 0.00 |
March | 915.47 | 536.41 | 686.81 | 353.30 | 333.51 | 0.00 | 0.00 |
April | 1621.10 | 305.16 | 980.38 | 584.32 | 396.06 | 0.00 | 0.00 |
May | 1789.81 | 216.75 | 1016.03 | 602.29 | 413.74 | 0.00 | 0.00 |
June | 2134.74 | 90.25 | 1059.03 | 658.06 | 400.96 | 0.00 | 0.00 |
July | 1820.88 | 68.18 | 894.42 | 504.32 | 390.09 | 0.00 | 0.00 |
August | 1717.54 | 85.70 | 848.88 | 484.45 | 364.43 | 0.00 | 0.00 |
September | 1357.65 | 126.86 | 696.56 | 335.75 | 360.81 | 0.00 | 0.00 |
October | 1106.36 | 387.68 | 699.66 | 425.80 | 273.85 | 0.00 | 0.00 |
November | 704.92 | 561.90 | 538.00 | 322.97 | 215.03 | 0.00 | 0.00 |
December | 586.67 | 718.13 | 490.51 | 296.18 | 194.33 | 0.00 | 0.00 |
Annual Sum or Average | 1264.55 | 356.60 | 752.25 | 436.46 | 315.79 | 0.00 | 0.00 |
Minimum of Months | 586.67 | 68.18 | 490.51 | 296.18 | 194.33 | 0.00 | 0.00 |
Maximum of Months | 2134.74 | 718.13 | 1059.03 | 658.06 | 413.74 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 3259.56 | 965.09 | 2128.69 | 1700.12 | 428.57 | 0.00 | 0.00 |
February | 1865.22 | 908.76 | 1345.94 | 907.75 | 438.19 | 0.00 | 0.00 |
March | 1664.74 | 856.87 | 1119.92 | 576.82 | 543.10 | 0.00 | 0.00 |
April | 1797.44 | 501.03 | 953.35 | 385.24 | 568.10 | 0.00 | 0.00 |
May | 1325.86 | 352.86 | 638.84 | 105.54 | 533.30 | 0.00 | 0.00 |
June | 1497.50 | 145.01 | 547.04 | 42.17 | 504.87 | 0.00 | 0.00 |
July | 1461.32 | 107.28 | 558.97 | 57.83 | 501.14 | 0.00 | 0.00 |
August | 1694.08 | 133.96 | 679.68 | 187.83 | 491.85 | 0.00 | 0.00 |
September | 2052.72 | 203.29 | 979.36 | 417.82 | 561.54 | 0.00 | 0.00 |
October | 2618.15 | 613.88 | 1560.51 | 1080.10 | 480.40 | 0.00 | 0.00 |
November | 2751.53 | 881.72 | 1818.58 | 1392.93 | 425.64 | 0.00 | 0.00 |
December | 2905.08 | 1130.01 | 1979.04 | 1566.68 | 412.37 | 0.00 | 0.00 |
Annual Sum or Average | 2076.70 | 565.30 | 1192.52 | 701.60 | 490.92 | 0.00 | 0.00 |
Minimum of Months | 1325.86 | 107.28 | 547.04 | 42.17 | 412.37 | 0.00 | 0.00 |
Maximum of Months | 3259.56 | 1130.01 | 2128.69 | 1700.12 | 568.10 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 860.37 | 662.04 | 582.21 | 361.85 | 220.36 | 0.00 | 0.00 |
February | 569.44 | 619.51 | 471.64 | 228.01 | 243.63 | 0.00 | 0.00 |
March | 862.18 | 568.42 | 624.71 | 297.81 | 326.90 | 0.00 | 0.00 |
April | 1632.23 | 341.67 | 959.26 | 547.19 | 412.07 | 0.00 | 0.00 |
May | 1739.73 | 247.85 | 961.72 | 539.24 | 422.48 | 0.00 | 0.00 |
June | 2092.30 | 108.09 | 1022.40 | 601.34 | 421.07 | 0.00 | 0.00 |
July | 1574.68 | 78.54 | 744.13 | 347.36 | 396.77 | 0.00 | 0.00 |
August | 1494.40 | 96.33 | 709.59 | 356.37 | 353.22 | 0.00 | 0.00 |
September | 1240.64 | 139.21 | 618.53 | 259.88 | 358.65 | 0.00 | 0.00 |
October | 1039.26 | 420.66 | 632.88 | 361.88 | 271.00 | 0.00 | 0.00 |
November | 837.60 | 605.40 | 582.90 | 351.94 | 230.96 | 0.00 | 0.00 |
December | 629.75 | 778.71 | 469.79 | 267.49 | 202.31 | 0.00 | 0.00 |
Annual Sum or Average | 1217.09 | 387.96 | 699.11 | 377.22 | 321.89 | 0.00 | 0.00 |
Minimum of Months | 569.44 | 78.54 | 469.79 | 228.01 | 202.31 | 0.00 | 0.00 |
Maximum of Months | 2092.30 | 778.71 | 1022.40 | 601.34 | 422.48 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 219.25 | 1035.44 | 258.52 | 0.00 | 258.52 | 0.00 | 0.00 |
February | 168.50 | 984.40 | 294.58 | 0.00 | 294.58 | 0.00 | 0.00 |
March | 404.68 | 863.04 | 391.50 | 0.00 | 391.50 | 0.00 | 0.00 |
April | 816.36 | 470.52 | 476.98 | 4.95 | 472.03 | 0.00 | 0.00 |
May | 1109.65 | 311.46 | 558.36 | 44.71 | 513.65 | 0.00 | 0.00 |
June | 1690.40 | 130.12 | 648.85 | 117.89 | 530.96 | 0.00 | 0.00 |
July | 1431.99 | 105.06 | 553.35 | 57.65 | 495.70 | 0.00 | 0.00 |
August | 1178.34 | 138.14 | 446.65 | 11.10 | 435.55 | 0.00 | 0.00 |
September | 976.20 | 217.86 | 421.41 | 0.11 | 421.29 | 0.00 | 0.00 |
October | 472.55 | 688.86 | 326.03 | 0.00 | 326.03 | 0.00 | 0.00 |
November | 203.58 | 1009.07 | 271.65 | 0.00 | 271.65 | 0.00 | 0.00 |
December | 125.08 | 1295.81 | 241.49 | 0.00 | 241.49 | 0.00 | 0.00 |
Annual Sum or Average | 735.62 | 602.64 | 407.86 | 19.74 | 388.12 | 0.00 | 0.00 |
Minimum of Months | 125.08 | 105.06 | 241.49 | 0.00 | 241.49 | 0.00 | 0.00 |
Maximum of Months | 1690.40 | 1295.81 | 648.85 | 117.89 | 530.96 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 726.67 | 660.10 | 556.77 | 349.27 | 207.49 | 0.00 | 0.00 |
February | 645.14 | 636.26 | 548.80 | 313.94 | 234.86 | 0.00 | 0.00 |
March | 922.78 | 556.85 | 686.80 | 353.29 | 333.51 | 0.00 | 0.00 |
April | 1636.70 | 313.48 | 980.37 | 584.31 | 396.06 | 0.00 | 0.00 |
May | 1808.54 | 218.29 | 1016.02 | 602.28 | 413.73 | 0.00 | 0.00 |
June | 2151.95 | 89.94 | 1059.02 | 658.06 | 400.96 | 0.00 | 0.00 |
July | 1829.28 | 72.81 | 894.41 | 504.32 | 390.09 | 0.00 | 0.00 |
August | 1721.59 | 95.99 | 848.87 | 484.45 | 364.42 | 0.00 | 0.00 |
September | 1355.55 | 143.43 | 696.56 | 335.75 | 360.81 | 0.00 | 0.00 |
October | 1096.96 | 438.16 | 699.65 | 425.80 | 273.85 | 0.00 | 0.00 |
November | 685.27 | 641.90 | 537.99 | 322.96 | 215.03 | 0.00 | 0.00 |
December | 557.89 | 815.90 | 490.51 | 296.18 | 194.33 | 0.00 | 0.00 |
Annual Sum or Average | 1264.45 | 389.26 | 752.24 | 436.46 | 315.79 | 0.00 | 0.00 |
Minimum of Months | 557.89 | 72.81 | 490.51 | 296.18 | 194.33 | 0.00 | 0.00 |
Maximum of Months | 2151.95 | 815.90 | 1059.02 | 658.06 | 413.73 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 3258.09 | 1079.15 | 2128.71 | 1700.14 | 428.57 | 0.00 | 0.00 |
February | 1884.43 | 978.44 | 1345.95 | 907.76 | 438.20 | 0.00 | 0.00 |
March | 1691.62 | 883.00 | 1119.93 | 576.82 | 543.11 | 0.00 | 0.00 |
April | 1820.08 | 508.51 | 953.36 | 385.25 | 568.11 | 0.00 | 0.00 |
May | 1347.90 | 343.76 | 638.85 | 105.54 | 533.30 | 0.00 | 0.00 |
June | 1507.59 | 137.42 | 547.04 | 42.17 | 504.87 | 0.00 | 0.00 |
July | 1462.26 | 109.92 | 558.98 | 57.83 | 501.15 | 0.00 | 0.00 |
August | 1682.53 | 148.44 | 679.69 | 187.83 | 491.86 | 0.00 | 0.00 |
September | 2036.77 | 234.46 | 979.37 | 417.82 | 561.55 | 0.00 | 0.00 |
October | 2607.76 | 697.87 | 1560.52 | 1080.11 | 480.41 | 0.00 | 0.00 |
November | 2739.52 | 1010.42 | 1818.60 | 1392.95 | 425.64 | 0.00 | 0.00 |
December | 2891.01 | 1284.73 | 1979.07 | 1566.70 | 412.37 | 0.00 | 0.00 |
Annual Sum or Average | 2079.61 | 616.64 | 1192.54 | 701.61 | 490.93 | 0.00 | 0.00 |
Minimum of Months | 1347.90 | 109.92 | 547.04 | 42.17 | 412.37 | 0.00 | 0.00 |
Maximum of Months | 3258.09 | 1284.73 | 2128.71 | 1700.14 | 568.11 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 853.31 | 726.49 | 582.20 | 361.85 | 220.36 | 0.00 | 0.00 |
February | 570.78 | 667.08 | 471.64 | 228.01 | 243.63 | 0.00 | 0.00 |
March | 870.72 | 591.18 | 624.70 | 297.80 | 326.90 | 0.00 | 0.00 |
April | 1645.73 | 354.01 | 959.25 | 547.18 | 412.07 | 0.00 | 0.00 |
May | 1755.58 | 252.35 | 961.71 | 539.23 | 422.48 | 0.00 | 0.00 |
June | 2107.51 | 109.28 | 1022.40 | 601.33 | 421.07 | 0.00 | 0.00 |
July | 1580.90 | 83.23 | 744.12 | 347.35 | 396.77 | 0.00 | 0.00 |
August | 1495.54 | 106.11 | 709.59 | 356.37 | 353.22 | 0.00 | 0.00 |
September | 1237.05 | 156.79 | 618.52 | 259.88 | 358.65 | 0.00 | 0.00 |
October | 1029.15 | 477.38 | 632.88 | 361.88 | 271.00 | 0.00 | 0.00 |
November | 821.63 | 696.35 | 582.90 | 351.93 | 230.96 | 0.00 | 0.00 |
December | 612.27 | 882.47 | 469.79 | 267.48 | 202.31 | 0.00 | 0.00 |
Annual Sum or Average | 1217.70 | 424.29 | 699.10 | 377.22 | 321.89 | 0.00 | 0.00 |
Minimum of Months | 570.78 | 83.23 | 469.79 | 228.01 | 202.31 | 0.00 | 0.00 |
Maximum of Months | 2107.51 | 882.47 | 1022.40 | 601.33 | 422.48 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 211.04 | 1048.50 | 258.53 | 0.00 | 258.53 | 0.00 | 0.00 |
February | 153.70 | 1016.67 | 294.58 | 0.00 | 294.58 | 0.00 | 0.00 |
March | 375.51 | 910.35 | 391.50 | 0.00 | 391.50 | 0.00 | 0.00 |
April | 796.26 | 497.58 | 476.99 | 4.95 | 472.04 | 0.00 | 0.00 |
May | 1087.76 | 333.77 | 558.36 | 44.71 | 513.65 | 0.00 | 0.00 |
June | 1676.69 | 141.39 | 648.85 | 117.89 | 530.96 | 0.00 | 0.00 |
July | 1431.25 | 107.21 | 553.35 | 57.65 | 495.70 | 0.00 | 0.00 |
August | 1184.07 | 136.24 | 446.65 | 11.10 | 435.56 | 0.00 | 0.00 |
September | 987.52 | 208.05 | 421.41 | 0.11 | 421.30 | 0.00 | 0.00 |
October | 481.59 | 663.46 | 326.03 | 0.00 | 326.03 | 0.00 | 0.00 |
November | 211.39 | 971.05 | 271.65 | 0.00 | 271.65 | 0.00 | 0.00 |
December | 131.68 | 1259.54 | 241.49 | 0.00 | 241.49 | 0.00 | 0.00 |
Annual Sum or Average | 730.00 | 606.14 | 407.86 | 19.74 | 388.12 | 0.00 | 0.00 |
Minimum of Months | 131.68 | 107.21 | 241.49 | 0.00 | 241.49 | 0.00 | 0.00 |
Maximum of Months | 1676.69 | 1259.54 | 648.85 | 117.89 | 530.96 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 722.89 | 647.20 | 556.77 | 349.28 | 207.49 | 0.00 | 0.00 |
February | 634.51 | 636.44 | 548.81 | 313.94 | 234.86 | 0.00 | 0.00 |
March | 905.28 | 566.51 | 686.81 | 353.30 | 333.51 | 0.00 | 0.00 |
April | 1624.57 | 314.99 | 980.38 | 584.32 | 396.06 | 0.00 | 0.00 |
May | 1796.31 | 221.91 | 1016.03 | 602.29 | 413.74 | 0.00 | 0.00 |
June | 2145.69 | 90.77 | 1059.03 | 658.06 | 400.96 | 0.00 | 0.00 |
July | 1831.87 | 68.65 | 894.42 | 504.32 | 390.09 | 0.00 | 0.00 |
August | 1726.43 | 87.56 | 848.88 | 484.45 | 364.43 | 0.00 | 0.00 |
September | 1363.07 | 130.56 | 696.56 | 335.75 | 360.81 | 0.00 | 0.00 |
October | 1102.19 | 410.66 | 699.66 | 425.80 | 273.85 | 0.00 | 0.00 |
November | 691.25 | 605.08 | 538.00 | 322.97 | 215.03 | 0.00 | 0.00 |
December | 565.84 | 775.15 | 490.51 | 296.18 | 194.33 | 0.00 | 0.00 |
Annual Sum or Average | 1262.14 | 378.54 | 752.25 | 436.46 | 315.79 | 0.00 | 0.00 |
Minimum of Months | 565.84 | 68.65 | 490.51 | 296.18 | 194.33 | 0.00 | 0.00 |
Maximum of Months | 2145.69 | 775.15 | 1059.03 | 658.06 | 413.74 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 3243.92 | 1028.57 | 2128.69 | 1700.12 | 428.57 | 0.00 | 0.00 |
February | 1849.21 | 982.04 | 1345.94 | 907.75 | 438.19 | 0.00 | 0.00 |
March | 1652.50 | 908.67 | 1119.92 | 576.82 | 543.10 | 0.00 | 0.00 |
April | 1801.63 | 522.50 | 953.35 | 385.24 | 568.10 | 0.00 | 0.00 |
May | 1331.81 | 365.13 | 638.84 | 105.54 | 533.30 | 0.00 | 0.00 |
June | 1509.29 | 147.45 | 547.04 | 42.17 | 504.87 | 0.00 | 0.00 |
July | 1474.12 | 109.02 | 558.97 | 57.83 | 501.14 | 0.00 | 0.00 |
August | 1704.47 | 137.81 | 679.68 | 187.83 | 491.85 | 0.00 | 0.00 |
September | 2060.47 | 210.23 | 979.36 | 417.82 | 561.54 | 0.00 | 0.00 |
October | 2613.61 | 650.56 | 1560.51 | 1080.10 | 480.40 | 0.00 | 0.00 |
November | 2735.54 | 944.98 | 1818.58 | 1392.93 | 425.64 | 0.00 | 0.00 |
December | 2881.91 | 1213.88 | 1979.04 | 1566.68 | 412.37 | 0.00 | 0.00 |
Annual Sum or Average | 2073.86 | 600.21 | 1192.52 | 701.60 | 490.92 | 0.00 | 0.00 |
Minimum of Months | 1331.81 | 109.02 | 547.04 | 42.17 | 412.37 | 0.00 | 0.00 |
Maximum of Months | 3243.92 | 1213.88 | 2128.69 | 1700.12 | 568.10 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 850.20 | 712.47 | 582.21 | 361.85 | 220.36 | 0.00 | 0.00 |
February | 560.37 | 672.66 | 471.64 | 228.01 | 243.63 | 0.00 | 0.00 |
March | 852.96 | 605.00 | 624.71 | 297.81 | 326.90 | 0.00 | 0.00 |
April | 1634.16 | 355.79 | 959.26 | 547.19 | 412.07 | 0.00 | 0.00 |
May | 1744.59 | 255.83 | 961.72 | 539.24 | 422.48 | 0.00 | 0.00 |
June | 2101.79 | 109.58 | 1022.40 | 601.34 | 421.07 | 0.00 | 0.00 |
July | 1583.51 | 79.62 | 744.13 | 347.36 | 396.77 | 0.00 | 0.00 |
August | 1501.23 | 98.77 | 709.59 | 356.37 | 353.22 | 0.00 | 0.00 |
September | 1244.57 | 143.92 | 618.53 | 259.88 | 358.65 | 0.00 | 0.00 |
October | 1035.03 | 449.12 | 632.88 | 361.88 | 271.00 | 0.00 | 0.00 |
November | 827.32 | 655.14 | 582.90 | 351.94 | 230.96 | 0.00 | 0.00 |
December | 617.20 | 842.65 | 469.79 | 267.49 | 202.31 | 0.00 | 0.00 |
Annual Sum or Average | 1215.49 | 414.01 | 699.11 | 377.22 | 321.89 | 0.00 | 0.00 |
Minimum of Months | 560.37 | 79.62 | 469.79 | 228.01 | 202.31 | 0.00 | 0.00 |
Maximum of Months | 2101.79 | 842.65 | 1022.40 | 601.34 | 422.48 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.613980E+09 | 0.259416E+10 | 0.692434E+09 | 0.00 | 0.692434E+09 | 0.00 | 0.00 |
February | 0.406605E+09 | 0.225386E+10 | 0.712656E+09 | 0.00 | 0.712656E+09 | 0.00 | 0.00 |
March | 0.104452E+10 | 0.228656E+10 | 0.104860E+10 | 0.00 | 0.104860E+10 | 0.00 | 0.00 |
April | 0.205862E+10 | 0.123672E+10 | 0.123635E+10 | 12830113.86 | 0.122352E+10 | 0.00 | 0.00 |
May | 0.289984E+10 | 0.872853E+09 | 0.149552E+10 | 0.119747E+09 | 0.137577E+10 | 0.00 | 0.00 |
June | 0.431357E+10 | 0.365585E+09 | 0.168183E+10 | 0.305571E+09 | 0.137626E+10 | 0.00 | 0.00 |
July | 0.379640E+10 | 0.286478E+09 | 0.148209E+10 | 0.154404E+09 | 0.132768E+10 | 0.00 | 0.00 |
August | 0.314527E+10 | 0.358341E+09 | 0.119631E+10 | 29719197.80 | 0.116659E+10 | 0.00 | 0.00 |
September | 0.254490E+10 | 0.522611E+09 | 0.109229E+10 | 291589.31 | 0.109200E+10 | 0.00 | 0.00 |
October | 0.130988E+10 | 0.165862E+10 | 0.873252E+09 | 0.00 | 0.873252E+09 | 0.00 | 0.00 |
November | 0.591709E+09 | 0.231213E+10 | 0.704109E+09 | 0.00 | 0.704109E+09 | 0.00 | 0.00 |
December | 0.406108E+09 | 0.309938E+10 | 0.646797E+09 | 0.00 | 0.646797E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.231314E+11 | 0.178473E+11 | 0.128622E+11 | 0.622563E+09 | 0.122397E+11 | 0.00 | 0.00 |
Minimum of Months | 0.406108E+09 | 0.286478E+09 | 0.646797E+09 | 0.00 | 0.646797E+09 | 0.00 | 0.00 |
Maximum of Months | 0.431357E+10 | 0.309938E+10 | 0.168183E+10 | 0.305571E+09 | 0.137626E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.197610E+10 | 0.161890E+10 | 0.149126E+10 | 0.935504E+09 | 0.555752E+09 | 0.00 | 0.00 |
February | 0.156353E+10 | 0.142557E+10 | 0.132767E+10 | 0.759488E+09 | 0.568185E+09 | 0.00 | 0.00 |
March | 0.245201E+10 | 0.143671E+10 | 0.183954E+10 | 0.946272E+09 | 0.893270E+09 | 0.00 | 0.00 |
April | 0.420189E+10 | 0.790969E+09 | 0.254114E+10 | 0.151455E+10 | 0.102659E+10 | 0.00 | 0.00 |
May | 0.479382E+10 | 0.580552E+09 | 0.272132E+10 | 0.161317E+10 | 0.110815E+10 | 0.00 | 0.00 |
June | 0.553326E+10 | 0.233928E+09 | 0.274500E+10 | 0.170570E+10 | 0.103930E+10 | 0.00 | 0.00 |
July | 0.487705E+10 | 0.182620E+09 | 0.239560E+10 | 0.135078E+10 | 0.104482E+10 | 0.00 | 0.00 |
August | 0.460025E+10 | 0.229534E+09 | 0.227364E+10 | 0.129756E+10 | 0.976078E+09 | 0.00 | 0.00 |
September | 0.351902E+10 | 0.328818E+09 | 0.180549E+10 | 0.870276E+09 | 0.935215E+09 | 0.00 | 0.00 |
October | 0.296328E+10 | 0.103835E+10 | 0.187396E+10 | 0.114048E+10 | 0.733484E+09 | 0.00 | 0.00 |
November | 0.182716E+10 | 0.145644E+10 | 0.139449E+10 | 0.837126E+09 | 0.557360E+09 | 0.00 | 0.00 |
December | 0.157134E+10 | 0.192345E+10 | 0.131379E+10 | 0.793301E+09 | 0.520486E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.398787E+11 | 0.112458E+11 | 0.237229E+11 | 0.137642E+11 | 0.995870E+10 | 0.00 | 0.00 |
Minimum of Months | 0.156353E+10 | 0.182620E+09 | 0.131379E+10 | 0.759488E+09 | 0.520486E+09 | 0.00 | 0.00 |
Maximum of Months | 0.553326E+10 | 0.192345E+10 | 0.274500E+10 | 0.170570E+10 | 0.110815E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.873041E+10 | 0.258490E+10 | 0.570147E+10 | 0.455360E+10 | 0.114787E+10 | 0.00 | 0.00 |
February | 0.451235E+10 | 0.219848E+10 | 0.325610E+10 | 0.219602E+10 | 0.106007E+10 | 0.00 | 0.00 |
March | 0.445885E+10 | 0.229505E+10 | 0.299960E+10 | 0.154495E+10 | 0.145465E+10 | 0.00 | 0.00 |
April | 0.465896E+10 | 0.129866E+10 | 0.247108E+10 | 0.998553E+09 | 0.147253E+10 | 0.00 | 0.00 |
May | 0.355118E+10 | 0.945111E+09 | 0.171108E+10 | 0.282688E+09 | 0.142839E+10 | 0.00 | 0.00 |
June | 0.388153E+10 | 0.375875E+09 | 0.141792E+10 | 0.109302E+09 | 0.130862E+10 | 0.00 | 0.00 |
July | 0.391401E+10 | 0.287335E+09 | 0.149716E+10 | 0.154892E+09 | 0.134227E+10 | 0.00 | 0.00 |
August | 0.453743E+10 | 0.358787E+09 | 0.182047E+10 | 0.503085E+09 | 0.131738E+10 | 0.00 | 0.00 |
September | 0.532064E+10 | 0.526926E+09 | 0.253850E+10 | 0.108298E+10 | 0.145552E+10 | 0.00 | 0.00 |
October | 0.701244E+10 | 0.164422E+10 | 0.417966E+10 | 0.289294E+10 | 0.128671E+10 | 0.00 | 0.00 |
November | 0.713196E+10 | 0.228542E+10 | 0.471375E+10 | 0.361049E+10 | 0.110326E+10 | 0.00 | 0.00 |
December | 0.778096E+10 | 0.302663E+10 | 0.530067E+10 | 0.419619E+10 | 0.110448E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.654907E+11 | 0.178274E+11 | 0.376074E+11 | 0.221257E+11 | 0.154818E+11 | 0.00 | 0.00 |
Minimum of Months | 0.355118E+10 | 0.287335E+09 | 0.141792E+10 | 0.109302E+09 | 0.106007E+10 | 0.00 | 0.00 |
Maximum of Months | 0.873041E+10 | 0.302663E+10 | 0.570147E+10 | 0.455360E+10 | 0.147253E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.230441E+10 | 0.177320E+10 | 0.155938E+10 | 0.969179E+09 | 0.590203E+09 | 0.00 | 0.00 |
February | 0.137759E+10 | 0.149872E+10 | 0.114100E+10 | 0.551603E+09 | 0.589398E+09 | 0.00 | 0.00 |
March | 0.230927E+10 | 0.152246E+10 | 0.167322E+10 | 0.797647E+09 | 0.875569E+09 | 0.00 | 0.00 |
April | 0.423073E+10 | 0.885610E+09 | 0.248640E+10 | 0.141831E+10 | 0.106808E+10 | 0.00 | 0.00 |
May | 0.465970E+10 | 0.663833E+09 | 0.257587E+10 | 0.144429E+10 | 0.113158E+10 | 0.00 | 0.00 |
June | 0.542325E+10 | 0.280160E+09 | 0.265007E+10 | 0.155867E+10 | 0.109141E+10 | 0.00 | 0.00 |
July | 0.421762E+10 | 0.210361E+09 | 0.199308E+10 | 0.930359E+09 | 0.106272E+10 | 0.00 | 0.00 |
August | 0.400261E+10 | 0.258008E+09 | 0.190058E+10 | 0.954507E+09 | 0.946071E+09 | 0.00 | 0.00 |
September | 0.321575E+10 | 0.360822E+09 | 0.160323E+10 | 0.673609E+09 | 0.929617E+09 | 0.00 | 0.00 |
October | 0.278355E+10 | 0.112670E+10 | 0.169511E+10 | 0.969260E+09 | 0.725854E+09 | 0.00 | 0.00 |
November | 0.217105E+10 | 0.156921E+10 | 0.151088E+10 | 0.912223E+09 | 0.598656E+09 | 0.00 | 0.00 |
December | 0.168673E+10 | 0.208568E+10 | 0.125830E+10 | 0.716434E+09 | 0.541863E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.383822E+11 | 0.122348E+11 | 0.220471E+11 | 0.118961E+11 | 0.101510E+11 | 0.00 | 0.00 |
Minimum of Months | 0.137759E+10 | 0.210361E+09 | 0.114100E+10 | 0.551603E+09 | 0.541863E+09 | 0.00 | 0.00 |
Maximum of Months | 0.542325E+10 | 0.208568E+10 | 0.265007E+10 | 0.155867E+10 | 0.113158E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.587250E+09 | 0.277332E+10 | 0.692431E+09 | 0.00 | 0.692431E+09 | 0.00 | 0.00 |
February | 0.407643E+09 | 0.238145E+10 | 0.712652E+09 | 0.00 | 0.712652E+09 | 0.00 | 0.00 |
March | 0.108390E+10 | 0.231156E+10 | 0.104859E+10 | 0.00 | 0.104859E+10 | 0.00 | 0.00 |
April | 0.211601E+10 | 0.121959E+10 | 0.123634E+10 | 12830047.38 | 0.122351E+10 | 0.00 | 0.00 |
May | 0.297208E+10 | 0.834211E+09 | 0.149551E+10 | 0.119747E+09 | 0.137576E+10 | 0.00 | 0.00 |
June | 0.438151E+10 | 0.337276E+09 | 0.168182E+10 | 0.305569E+09 | 0.137625E+10 | 0.00 | 0.00 |
July | 0.383546E+10 | 0.281404E+09 | 0.148208E+10 | 0.154403E+09 | 0.132768E+10 | 0.00 | 0.00 |
August | 0.315605E+10 | 0.369994E+09 | 0.119631E+10 | 29719043.80 | 0.116659E+10 | 0.00 | 0.00 |
September | 0.253031E+10 | 0.564696E+09 | 0.109229E+10 | 291587.80 | 0.109200E+10 | 0.00 | 0.00 |
October | 0.126567E+10 | 0.184505E+10 | 0.873247E+09 | 0.00 | 0.873247E+09 | 0.00 | 0.00 |
November | 0.527669E+09 | 0.261552E+10 | 0.704105E+09 | 0.00 | 0.704105E+09 | 0.00 | 0.00 |
December | 0.335018E+09 | 0.347071E+10 | 0.646794E+09 | 0.00 | 0.646794E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.231986E+11 | 0.190048E+11 | 0.128622E+11 | 0.622560E+09 | 0.122396E+11 | 0.00 | 0.00 |
Minimum of Months | 0.335018E+09 | 0.281404E+09 | 0.646794E+09 | 0.00 | 0.646794E+09 | 0.00 | 0.00 |
Maximum of Months | 0.438151E+10 | 0.347071E+10 | 0.168182E+10 | 0.305569E+09 | 0.137625E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.194631E+10 | 0.176802E+10 | 0.149124E+10 | 0.935495E+09 | 0.555750E+09 | 0.00 | 0.00 |
February | 0.156072E+10 | 0.153924E+10 | 0.132766E+10 | 0.759480E+09 | 0.568182E+09 | 0.00 | 0.00 |
March | 0.247157E+10 | 0.149145E+10 | 0.183953E+10 | 0.946262E+09 | 0.893265E+09 | 0.00 | 0.00 |
April | 0.424233E+10 | 0.812541E+09 | 0.254112E+10 | 0.151453E+10 | 0.102659E+10 | 0.00 | 0.00 |
May | 0.484398E+10 | 0.584660E+09 | 0.272130E+10 | 0.161316E+10 | 0.110815E+10 | 0.00 | 0.00 |
June | 0.557786E+10 | 0.233115E+09 | 0.274498E+10 | 0.170568E+10 | 0.103930E+10 | 0.00 | 0.00 |
July | 0.489955E+10 | 0.195007E+09 | 0.239559E+10 | 0.135077E+10 | 0.104482E+10 | 0.00 | 0.00 |
August | 0.461112E+10 | 0.257090E+09 | 0.227362E+10 | 0.129755E+10 | 0.976073E+09 | 0.00 | 0.00 |
September | 0.351359E+10 | 0.371777E+09 | 0.180548E+10 | 0.870267E+09 | 0.935210E+09 | 0.00 | 0.00 |
October | 0.293809E+10 | 0.117356E+10 | 0.187394E+10 | 0.114046E+10 | 0.733480E+09 | 0.00 | 0.00 |
November | 0.177622E+10 | 0.166380E+10 | 0.139448E+10 | 0.837118E+09 | 0.557357E+09 | 0.00 | 0.00 |
December | 0.149426E+10 | 0.218530E+10 | 0.131378E+10 | 0.793293E+09 | 0.520484E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.398756E+11 | 0.122756E+11 | 0.237227E+11 | 0.137641E+11 | 0.995865E+10 | 0.00 | 0.00 |
Minimum of Months | 0.149426E+10 | 0.195007E+09 | 0.131378E+10 | 0.759480E+09 | 0.520484E+09 | 0.00 | 0.00 |
Maximum of Months | 0.557786E+10 | 0.218530E+10 | 0.274498E+10 | 0.170568E+10 | 0.110815E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.872646E+10 | 0.289038E+10 | 0.570153E+10 | 0.455365E+10 | 0.114788E+10 | 0.00 | 0.00 |
February | 0.455880E+10 | 0.236704E+10 | 0.325613E+10 | 0.219605E+10 | 0.106008E+10 | 0.00 | 0.00 |
March | 0.453084E+10 | 0.236503E+10 | 0.299963E+10 | 0.154496E+10 | 0.145466E+10 | 0.00 | 0.00 |
April | 0.471765E+10 | 0.131807E+10 | 0.247110E+10 | 0.998564E+09 | 0.147253E+10 | 0.00 | 0.00 |
May | 0.361021E+10 | 0.920716E+09 | 0.171109E+10 | 0.282692E+09 | 0.142840E+10 | 0.00 | 0.00 |
June | 0.390767E+10 | 0.356193E+09 | 0.141792E+10 | 0.109304E+09 | 0.130862E+10 | 0.00 | 0.00 |
July | 0.391651E+10 | 0.294413E+09 | 0.149717E+10 | 0.154894E+09 | 0.134227E+10 | 0.00 | 0.00 |
August | 0.450649E+10 | 0.397586E+09 | 0.182048E+10 | 0.503091E+09 | 0.131739E+10 | 0.00 | 0.00 |
September | 0.527931E+10 | 0.607723E+09 | 0.253852E+10 | 0.108300E+10 | 0.145553E+10 | 0.00 | 0.00 |
October | 0.698463E+10 | 0.186916E+10 | 0.417970E+10 | 0.289298E+10 | 0.128672E+10 | 0.00 | 0.00 |
November | 0.710085E+10 | 0.261902E+10 | 0.471380E+10 | 0.361053E+10 | 0.110327E+10 | 0.00 | 0.00 |
December | 0.774328E+10 | 0.344102E+10 | 0.530073E+10 | 0.419624E+10 | 0.110449E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.655827E+11 | 0.194464E+11 | 0.376078E+11 | 0.221260E+11 | 0.154818E+11 | 0.00 | 0.00 |
Minimum of Months | 0.361021E+10 | 0.294413E+09 | 0.141792E+10 | 0.109304E+09 | 0.106008E+10 | 0.00 | 0.00 |
Maximum of Months | 0.872646E+10 | 0.344102E+10 | 0.570153E+10 | 0.455365E+10 | 0.147253E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.228551E+10 | 0.194583E+10 | 0.155937E+10 | 0.969169E+09 | 0.590200E+09 | 0.00 | 0.00 |
February | 0.138082E+10 | 0.161379E+10 | 0.114099E+10 | 0.551598E+09 | 0.589395E+09 | 0.00 | 0.00 |
March | 0.233213E+10 | 0.158343E+10 | 0.167320E+10 | 0.797639E+09 | 0.875565E+09 | 0.00 | 0.00 |
April | 0.426573E+10 | 0.917601E+09 | 0.248638E+10 | 0.141830E+10 | 0.106808E+10 | 0.00 | 0.00 |
May | 0.470215E+10 | 0.675897E+09 | 0.257585E+10 | 0.144428E+10 | 0.113158E+10 | 0.00 | 0.00 |
June | 0.546267E+10 | 0.283262E+09 | 0.265005E+10 | 0.155865E+10 | 0.109140E+10 | 0.00 | 0.00 |
July | 0.423427E+10 | 0.222934E+09 | 0.199306E+10 | 0.930349E+09 | 0.106271E+10 | 0.00 | 0.00 |
August | 0.400566E+10 | 0.284192E+09 | 0.190056E+10 | 0.954497E+09 | 0.946067E+09 | 0.00 | 0.00 |
September | 0.320643E+10 | 0.406390E+09 | 0.160321E+10 | 0.673602E+09 | 0.929612E+09 | 0.00 | 0.00 |
October | 0.275649E+10 | 0.127861E+10 | 0.169510E+10 | 0.969251E+09 | 0.725851E+09 | 0.00 | 0.00 |
November | 0.212966E+10 | 0.180493E+10 | 0.151087E+10 | 0.912214E+09 | 0.598654E+09 | 0.00 | 0.00 |
December | 0.163990E+10 | 0.236361E+10 | 0.125829E+10 | 0.716427E+09 | 0.541860E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.384014E+11 | 0.133805E+11 | 0.220469E+11 | 0.118960E+11 | 0.101510E+11 | 0.00 | 0.00 |
Minimum of Months | 0.138082E+10 | 0.222934E+09 | 0.114099E+10 | 0.551598E+09 | 0.541860E+09 | 0.00 | 0.00 |
Maximum of Months | 0.546267E+10 | 0.236361E+10 | 0.265005E+10 | 0.155865E+10 | 0.113158E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.565250E+09 | 0.280830E+10 | 0.692434E+09 | 0.00 | 0.692434E+09 | 0.00 | 0.00 |
February | 0.371834E+09 | 0.245953E+10 | 0.712656E+09 | 0.00 | 0.712656E+09 | 0.00 | 0.00 |
March | 0.100577E+10 | 0.243828E+10 | 0.104860E+10 | 0.00 | 0.104860E+10 | 0.00 | 0.00 |
April | 0.206391E+10 | 0.128973E+10 | 0.123635E+10 | 12830113.86 | 0.122352E+10 | 0.00 | 0.00 |
May | 0.291347E+10 | 0.893974E+09 | 0.149552E+10 | 0.119747E+09 | 0.137577E+10 | 0.00 | 0.00 |
June | 0.434598E+10 | 0.366484E+09 | 0.168183E+10 | 0.305571E+09 | 0.137626E+10 | 0.00 | 0.00 |
July | 0.383346E+10 | 0.287164E+09 | 0.148209E+10 | 0.154404E+09 | 0.132768E+10 | 0.00 | 0.00 |
August | 0.317142E+10 | 0.364902E+09 | 0.119631E+10 | 29719197.80 | 0.116659E+10 | 0.00 | 0.00 |
September | 0.255965E+10 | 0.539277E+09 | 0.109229E+10 | 291589.31 | 0.109200E+10 | 0.00 | 0.00 |
October | 0.128990E+10 | 0.177700E+10 | 0.873252E+09 | 0.00 | 0.873252E+09 | 0.00 | 0.00 |
November | 0.547914E+09 | 0.251695E+10 | 0.704109E+09 | 0.00 | 0.704109E+09 | 0.00 | 0.00 |
December | 0.352687E+09 | 0.337356E+10 | 0.646797E+09 | 0.00 | 0.646797E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.230212E+11 | 0.191152E+11 | 0.128622E+11 | 0.622563E+09 | 0.122397E+11 | 0.00 | 0.00 |
Minimum of Months | 0.352687E+09 | 0.287164E+09 | 0.646797E+09 | 0.00 | 0.646797E+09 | 0.00 | 0.00 |
Maximum of Months | 0.434598E+10 | 0.337356E+10 | 0.168183E+10 | 0.305571E+09 | 0.137626E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.193620E+10 | 0.173346E+10 | 0.149126E+10 | 0.935504E+09 | 0.555752E+09 | 0.00 | 0.00 |
February | 0.153502E+10 | 0.153967E+10 | 0.132767E+10 | 0.759488E+09 | 0.568185E+09 | 0.00 | 0.00 |
March | 0.242471E+10 | 0.151733E+10 | 0.183954E+10 | 0.946272E+09 | 0.893270E+09 | 0.00 | 0.00 |
April | 0.421088E+10 | 0.816446E+09 | 0.254114E+10 | 0.151455E+10 | 0.102659E+10 | 0.00 | 0.00 |
May | 0.481124E+10 | 0.594373E+09 | 0.272132E+10 | 0.161317E+10 | 0.110815E+10 | 0.00 | 0.00 |
June | 0.556164E+10 | 0.235276E+09 | 0.274500E+10 | 0.170570E+10 | 0.103930E+10 | 0.00 | 0.00 |
July | 0.490648E+10 | 0.183884E+09 | 0.239560E+10 | 0.135078E+10 | 0.104482E+10 | 0.00 | 0.00 |
August | 0.462407E+10 | 0.234508E+09 | 0.227364E+10 | 0.129756E+10 | 0.976078E+09 | 0.00 | 0.00 |
September | 0.353308E+10 | 0.338404E+09 | 0.180549E+10 | 0.870276E+09 | 0.935215E+09 | 0.00 | 0.00 |
October | 0.295212E+10 | 0.109992E+10 | 0.187396E+10 | 0.114048E+10 | 0.733484E+09 | 0.00 | 0.00 |
November | 0.179173E+10 | 0.156837E+10 | 0.139449E+10 | 0.837126E+09 | 0.557360E+09 | 0.00 | 0.00 |
December | 0.151553E+10 | 0.207616E+10 | 0.131379E+10 | 0.793301E+09 | 0.520486E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.398027E+11 | 0.119378E+11 | 0.237229E+11 | 0.137642E+11 | 0.995870E+10 | 0.00 | 0.00 |
Minimum of Months | 0.151553E+10 | 0.183884E+09 | 0.131379E+10 | 0.759488E+09 | 0.520486E+09 | 0.00 | 0.00 |
Maximum of Months | 0.556164E+10 | 0.207616E+10 | 0.274500E+10 | 0.170570E+10 | 0.110815E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.868850E+10 | 0.275493E+10 | 0.570147E+10 | 0.455360E+10 | 0.114787E+10 | 0.00 | 0.00 |
February | 0.447361E+10 | 0.237575E+10 | 0.325610E+10 | 0.219602E+10 | 0.106007E+10 | 0.00 | 0.00 |
March | 0.442606E+10 | 0.243377E+10 | 0.299960E+10 | 0.154495E+10 | 0.145465E+10 | 0.00 | 0.00 |
April | 0.466984E+10 | 0.135432E+10 | 0.247108E+10 | 0.998553E+09 | 0.147253E+10 | 0.00 | 0.00 |
May | 0.356713E+10 | 0.977961E+09 | 0.171108E+10 | 0.282688E+09 | 0.142839E+10 | 0.00 | 0.00 |
June | 0.391207E+10 | 0.382184E+09 | 0.141792E+10 | 0.109302E+09 | 0.130862E+10 | 0.00 | 0.00 |
July | 0.394827E+10 | 0.292012E+09 | 0.149716E+10 | 0.154892E+09 | 0.134227E+10 | 0.00 | 0.00 |
August | 0.456524E+10 | 0.369107E+09 | 0.182047E+10 | 0.503085E+09 | 0.131738E+10 | 0.00 | 0.00 |
September | 0.534073E+10 | 0.544926E+09 | 0.253850E+10 | 0.108298E+10 | 0.145552E+10 | 0.00 | 0.00 |
October | 0.700030E+10 | 0.174247E+10 | 0.417966E+10 | 0.289294E+10 | 0.128671E+10 | 0.00 | 0.00 |
November | 0.709053E+10 | 0.244939E+10 | 0.471375E+10 | 0.361049E+10 | 0.110326E+10 | 0.00 | 0.00 |
December | 0.771892E+10 | 0.325126E+10 | 0.530067E+10 | 0.419619E+10 | 0.110448E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.654012E+11 | 0.189281E+11 | 0.376074E+11 | 0.221257E+11 | 0.154818E+11 | 0.00 | 0.00 |
Minimum of Months | 0.356713E+10 | 0.292012E+09 | 0.141792E+10 | 0.109302E+09 | 0.106007E+10 | 0.00 | 0.00 |
Maximum of Months | 0.868850E+10 | 0.325126E+10 | 0.570147E+10 | 0.455360E+10 | 0.147253E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.227718E+10 | 0.190827E+10 | 0.155938E+10 | 0.969179E+09 | 0.590203E+09 | 0.00 | 0.00 |
February | 0.135564E+10 | 0.162730E+10 | 0.114100E+10 | 0.551603E+09 | 0.589398E+09 | 0.00 | 0.00 |
March | 0.228457E+10 | 0.162044E+10 | 0.167322E+10 | 0.797647E+09 | 0.875569E+09 | 0.00 | 0.00 |
April | 0.423574E+10 | 0.922219E+09 | 0.248640E+10 | 0.141831E+10 | 0.106808E+10 | 0.00 | 0.00 |
May | 0.467270E+10 | 0.685224E+09 | 0.257587E+10 | 0.144429E+10 | 0.113158E+10 | 0.00 | 0.00 |
June | 0.544785E+10 | 0.284036E+09 | 0.265007E+10 | 0.155867E+10 | 0.109141E+10 | 0.00 | 0.00 |
July | 0.424128E+10 | 0.213249E+09 | 0.199308E+10 | 0.930359E+09 | 0.106272E+10 | 0.00 | 0.00 |
August | 0.402090E+10 | 0.264541E+09 | 0.190058E+10 | 0.954507E+09 | 0.946071E+09 | 0.00 | 0.00 |
September | 0.322593E+10 | 0.373034E+09 | 0.160323E+10 | 0.673609E+09 | 0.929617E+09 | 0.00 | 0.00 |
October | 0.277224E+10 | 0.120291E+10 | 0.169511E+10 | 0.969260E+09 | 0.725854E+09 | 0.00 | 0.00 |
November | 0.214440E+10 | 0.169813E+10 | 0.151088E+10 | 0.912223E+09 | 0.598656E+09 | 0.00 | 0.00 |
December | 0.165312E+10 | 0.225695E+10 | 0.125830E+10 | 0.716434E+09 | 0.541863E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.383315E+11 | 0.130563E+11 | 0.220471E+11 | 0.118961E+11 | 0.101510E+11 | 0.00 | 0.00 |
Minimum of Months | 0.135564E+10 | 0.213249E+09 | 0.114100E+10 | 0.551603E+09 | 0.541863E+09 | 0.00 | 0.00 |
Maximum of Months | 0.544785E+10 | 0.225695E+10 | 0.265007E+10 | 0.155867E+10 | 0.113158E+10 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | 14.83 | 7.47 | -0.8 | 2.99 | -0.8 | 34.08 | 283.26 | 0.00 |
February | 12.72 | 9.35 | 6.24 | 2.64 | 2.53 | 52.02 | 191.85 | 0.02 |
March | 15.42 | 8.67 | 1.96 | 3.53 | 3.02 | 74.19 | 207.67 | 0.01 |
April | 23.31 | 10.14 | -4.1 | 3.42 | 6.81 | 72.47 | 350.22 | 0.00 |
May | 26.31 | 11.07 | -4.9 | 3.62 | 8.60 | 75.22 | 359.64 | 0.00 |
June | 31.20 | 14.28 | 0.18 | 3.69 | 15.53 | 67.31 | 396.02 | 0.00 |
July | 30.42 | 17.99 | 9.86 | 3.72 | 19.28 | 82.46 | 278.62 | 0.02 |
August | 29.82 | 18.15 | 11.14 | 3.33 | 18.26 | 71.82 | 270.19 | 0.02 |
September | 27.75 | 17.59 | 11.45 | 3.72 | 17.29 | 82.54 | 200.28 | 0.01 |
October | 20.87 | 10.99 | 1.63 | 3.42 | 6.03 | 49.01 | 269.00 | 0.00 |
November | 15.43 | 8.80 | 1.49 | 3.02 | 1.83 | 40.49 | 251.35 | 0.01 |
December | 11.86 | 4.25 | -5.9 | 2.21 | -4.3 | 34.74 | 244.35 | 0.00 |
Annual Sum or Average | 21.70 | 11.57 | 2.33 | 3.28 | 7.86 | 61.39 | 275.62 | 0.01 |
Minimum of Months | 11.86 | 4.25 | -5.9 | 2.21 | -4.3 | 34.08 | 191.85 | 0.00 |
Maximum of Months | 31.20 | 18.15 | 11.45 | 3.72 | 19.28 | 82.54 | 396.02 | 0.02 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 29.00 | 31-JAN-15:00 | 10.73 | -14.0 | 2.10 | 7.75 | 109.00 | 697.00 |
February | 22.00 | 18-FEB-14:09 | 14.42 | 9.67 | 5.20 | 14.10 | 264.00 | 225.33 |
March | 28.80 | 16-MAR-15:20 | 13.79 | 1.47 | 3.77 | 14.35 | 156.17 | 666.17 |
April | 35.00 | 14-APR-14:00 | 14.57 | -4.0 | 1.50 | 19.70 | 150.00 | 819.50 |
May | 37.00 | 15-MAY-16:00 | 15.57 | -2.0 | 4.60 | 20.75 | 127.50 | 679.00 |
June | 42.00 | 16-JUN-15:00 | 16.74 | -5.0 | 5.70 | 25.49 | 135.00 | 753.50 |
July | 40.00 | 12-JUL-13:00 | 19.40 | 7.00 | 2.10 | 27.95 | 147.00 | 3.00 |
August | 41.00 | 25-AUG-14:09 | 17.27 | -0.7 | 3.43 | 25.74 | 162.33 | 768.67 |
September | 38.30 | 08-SEP-14:00 | 19.81 | 10.00 | 3.00 | 25.82 | 142.00 | 699.00 |
October | 37.00 | 01-OCT-12:00 | 19.01 | 9.00 | 4.10 | 27.14 | 262.50 | 136.00 |
November | 29.00 | 01-NOV-14:00 | 16.20 | 8.00 | 2.60 | 16.49 | 73.50 | 907.50 |
December | 26.00 | 21-DEC-14:00 | 10.90 | -5.0 | 2.60 | 7.35 | 68.50 | 756.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 22.00 | 10.73 | -14.0 | 1.50 | 7.35 | 68.50 | 3.00 | |
Maximum of Months | 42.00 | 19.81 | 10.00 | 5.70 | 27.95 | 264.00 | 907.50 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 0.50 | 01-JAN-07:00 | -1.2 | -3.3 | 3.30 | -16.2 | 17.50 | 352.00 |
February | 5.00 | 01-FEB-04:00 | 3.59 | 2.00 | 3.10 | -10.7 | 0.00 | 0.00 |
March | 0.50 | 26-MAR-03:00 | -2.4 | -6.7 | 2.50 | -17.0 | 0.00 | 0.00 |
April | 8.00 | 21-APR-03:00 | 0.42 | -14.0 | 1.00 | -11.7 | 0.00 | 0.00 |
May | 12.00 | 01-MAY-03:00 | 3.97 | -7.0 | 2.60 | -6.2 | 0.00 | 0.00 |
June | 18.00 | 21-JUN-04:00 | 8.24 | -2.0 | 1.50 | 3.48 | 0.00 | 0.00 |
July | 18.00 | 01-JUL-05:00 | 6.53 | -9.0 | 3.10 | -1.2 | 16.00 | 325.00 |
August | 17.00 | 05-AUG-17:00 | 15.02 | 14.00 | 5.70 | 11.46 | 29.00 | 0.00 |
September | 16.60 | 22-SEP-05:00 | 13.83 | 12.20 | 3.00 | 4.92 | 0.00 | 0.00 |
October | 5.00 | 25-OCT-05:00 | 0.48 | -6.0 | 3.10 | -12.7 | 0.00 | 0.00 |
November | 0.00 | 23-NOV-05:00 | -2.5 | -6.0 | 2.10 | -17.3 | 0.00 | 0.00 |
December | -1.1 | 07-DEC-04:00 | -5.6 | -16.0 | 3.10 | -20.8 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -1.1 | -5.6 | -16.0 | 1.00 | -20.8 | 0.00 | 0.00 | |
Maximum of Months | 18.00 | 15.02 | 14.00 | 5.70 | 11.46 | 29.00 | 352.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 16.66 | 08-JAN-15:00 | 18.00 | 16.00 | 4.60 | 11.46 | 102.00 | 332.00 |
February | 14.73 | 18-FEB-17:00 | 16.00 | 14.00 | 6.20 | 10.50 | 0.00 | 0.00 |
March | 15.18 | 17-MAR-10:00 | 25.50 | 8.30 | 2.50 | 18.46 | 167.50 | 459.00 |
April | 15.71 | 11-APR-14:00 | 33.00 | 3.00 | 2.10 | 15.94 | 178.50 | 758.00 |
May | 15.57 | 15-MAY-16:00 | 37.00 | -2.0 | 4.60 | 20.75 | 127.50 | 679.00 |
June | 23.18 | 17-JUN-15:00 | 41.00 | 16.00 | 3.60 | 31.13 | 257.00 | 9.00 |
July | 23.11 | 13-JUL-17:00 | 26.00 | 22.00 | 4.60 | 22.13 | 79.00 | 56.50 |
August | 22.19 | 16-AUG-10:00 | 35.00 | 17.00 | 2.10 | 24.33 | 140.50 | 837.00 |
September | 22.23 | 01-SEP-11:00 | 34.40 | 17.20 | 4.60 | 23.82 | 193.50 | 725.50 |
October | 21.53 | 01-OCT-17:00 | 32.00 | 17.00 | 2.10 | 25.33 | 30.50 | 1.50 |
November | 18.59 | 12-NOV-14:00 | 20.00 | 18.00 | 3.10 | 15.39 | 115.00 | 0.00 |
December | 12.06 | 12-DEC-12:00 | 20.00 | 6.00 | 1.50 | 12.60 | 182.50 | 6.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 12.06 | 16.00 | -2.0 | 1.50 | 10.50 | 0.00 | 0.00 | |
Maximum of Months | 23.18 | 41.00 | 22.00 | 6.20 | 31.13 | 257.00 | 837.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 16.00 | 08-JAN-15:00 | 18.00 | 16.66 | 4.60 | 11.46 | 102.00 | 332.00 |
February | 14.00 | 18-FEB-17:00 | 16.00 | 14.73 | 6.20 | 10.50 | 0.00 | 0.00 |
March | 13.30 | 06-MAR-10:00 | 14.40 | 13.70 | 6.10 | 10.69 | 254.50 | 82.00 |
April | 8.00 | 15-APR-20:00 | 23.00 | 14.00 | 6.20 | 7.75 | 0.00 | 0.00 |
May | 9.00 | 26-MAY-02:00 | 21.00 | 13.75 | 3.60 | 16.30 | 0.00 | 0.00 |
June | 16.00 | 17-JUN-15:00 | 41.00 | 23.18 | 3.60 | 31.13 | 257.00 | 9.00 |
July | 22.00 | 13-JUL-17:00 | 26.00 | 23.11 | 4.60 | 22.13 | 79.00 | 56.50 |
August | 20.00 | 09-AUG-17:00 | 25.00 | 21.44 | 5.10 | 19.17 | 35.00 | 0.00 |
September | 20.50 | 02-SEP-22:10 | 22.62 | 21.05 | 3.18 | 20.17 | 0.00 | 0.00 |
October | 19.00 | 03-OCT-02:00 | 23.00 | 20.15 | 2.10 | 10.30 | 0.00 | 0.00 |
November | 18.00 | 12-NOV-14:00 | 20.00 | 18.59 | 3.10 | 15.39 | 115.00 | 0.00 |
December | 10.00 | 12-DEC-23:00 | 12.00 | 10.87 | 1.50 | 7.55 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 8.00 | 12.00 | 10.87 | 1.50 | 7.55 | 0.00 | 0.00 | |
Maximum of Months | 22.00 | 41.00 | 23.18 | 6.20 | 31.13 | 257.00 | 332.00 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 18.65 | 31.23 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 19.06 | 29.93 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 20.99 | 39.76 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 24.03 | 60.89 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 27.32 | 65.75 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 29.99 | 69.24 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 31.31 | 56.42 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 30.91 | 52.05 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 28.91 | 42.71 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 25.85 | 39.20 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 22.56 | 30.64 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 19.93 | 27.41 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 24.99 | 45.50 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 18.65 | 27.41 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 31.31 | 69.24 | 0.00 |
Report: WaterHeaterReportMonthly
For: SWHSYS1 WATER HEATER
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.450812E+10 | -0.381233E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -695790245.2 | 58.98 | 0.00 | 0.00 |
February | 0.406126E+10 | -0.343049E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -630776017.2 | 58.97 | 0.00 | 0.00 |
March | 0.455627E+10 | -0.386172E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -694547329.4 | 58.98 | 0.00 | 0.00 |
April | 0.386798E+10 | -0.319916E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -668819166.7 | 58.98 | 0.00 | 0.00 |
May | 0.380395E+10 | -0.311356E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -690389703.6 | 58.98 | 0.00 | 0.00 |
June | 0.349565E+10 | -0.282780E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -667842532.8 | 58.98 | 0.00 | 0.00 |
July | 0.323215E+10 | -0.254337E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -688785283.2 | 58.98 | 0.00 | 0.00 |
August | 0.354487E+10 | -0.285489E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -689971419.6 | 58.98 | 0.00 | 0.00 |
September | 0.342220E+10 | -0.275693E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -665269849.0 | 58.97 | 0.00 | 0.00 |
October | 0.382330E+10 | -0.313427E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -689027931.7 | 58.98 | 0.00 | 0.00 |
November | 0.405384E+10 | -0.338469E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -669153506.6 | 58.98 | 0.00 | 0.00 |
December | 0.428685E+10 | -0.358957E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -697284332.7 | 58.98 | 0.00 | 0.00 |
Annual Sum or Average | 0.466564E+11 | -0.385088E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.814766E+10 | 58.98 | 0.00 | 0.00 |
Minimum of Months | 0.323215E+10 | -0.386172E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -697284332.7 | 58.97 | 0.00 | 0.00 |
Maximum of Months | 0.455627E+10 | -0.254337E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -630776017.2 | 58.98 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_1_DAYLCTRL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 309.83 | 0.50 | 0.48 | 01-JAN-07:00 | 8248.13 | 38.40 | 306.33 | 289.50 | 2120.28 | 27.99 | 157.83 | 284.67 |
February | 241.00 | 0.50 | 0.48 | 01-FEB-07:49 | 7418.44 | 35.81 | 233.83 | 260.83 | 1142.11 | 22.12 | 94.17 | 215.50 |
March | 344.33 | 0.52 | 0.48 | 01-MAR-07:30 | 1344.96 | 16.61 | 2.33 | 321.67 | 795.04 | 19.37 | 44.83 | 275.67 |
April | 380.33 | 0.52 | 0.48 | 01-APR-08:09 | 1023.67 | 16.27 | 0.00 | 323.33 | 651.01 | 19.01 | 12.33 | 286.33 |
May | 403.17 | 0.52 | 0.48 | 01-MAY-07:40 | 803.61 | 15.98 | 0.00 | 345.50 | 510.59 | 18.78 | 0.00 | 291.33 |
June | 418.17 | 0.53 | 0.48 | 01-JUN-07:30 | 662.78 | 15.17 | 0.00 | 347.00 | 433.04 | 18.03 | 0.00 | 267.67 |
July | 399.50 | 0.53 | 0.48 | 01-JUL-07:00 | 776.45 | 15.61 | 0.00 | 346.50 | 472.78 | 18.41 | 0.00 | 261.17 |
August | 361.83 | 0.52 | 0.48 | 01-AUG-07:00 | 895.83 | 16.00 | 0.00 | 325.67 | 551.09 | 18.78 | 2.83 | 263.33 |
September | 350.17 | 0.52 | 0.48 | 01-SEP-07:10 | 1302.40 | 17.07 | 10.83 | 311.33 | 737.06 | 19.34 | 43.50 | 274.00 |
October | 348.00 | 0.51 | 0.48 | 01-OCT-07:19 | 2784.01 | 22.88 | 137.50 | 313.33 | 981.68 | 19.34 | 49.67 | 293.00 |
November | 288.50 | 0.50 | 0.48 | 01-NOV-07:40 | 7771.04 | 36.18 | 272.33 | 280.50 | 1433.40 | 24.53 | 118.17 | 263.50 |
December | 290.67 | 0.50 | 0.48 | 01-DEC-07:40 | 7586.56 | 37.31 | 278.83 | 276.33 | 1971.45 | 27.65 | 143.83 | 272.00 |
Annual Sum or Average | 4135.50 | 0.52 | 2975.05 | 22.36 | 1242.00 | 3741.50 | 922.51 | 20.74 | 667.17 | 3248.17 | ||
Minimum of Months | 241.00 | 0.50 | 0.48 | 662.78 | 15.17 | 0.00 | 260.83 | 433.04 | 18.03 | 0.00 | 215.50 | |
Maximum of Months | 418.17 | 0.53 | 0.48 | 8248.13 | 38.40 | 306.33 | 347.00 | 2120.28 | 27.99 | 157.83 | 293.00 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_2_DAYLCTRL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 309.83 | 0.53 | 0.48 | 01-JAN-07:00 | 1818.39 | 19.21 | 86.50 | 248.50 | 1043.94 | 22.30 | 74.67 | 187.67 |
February | 241.00 | 0.52 | 0.48 | 01-FEB-07:49 | 2147.10 | 18.99 | 65.00 | 235.33 | 1280.39 | 22.76 | 62.83 | 159.17 |
March | 344.33 | 0.52 | 0.48 | 01-MAR-07:30 | 1860.45 | 18.45 | 85.17 | 298.17 | 960.79 | 19.89 | 56.83 | 253.50 |
April | 380.33 | 0.51 | 0.48 | 01-APR-06:40 | 2686.77 | 20.18 | 112.33 | 339.17 | 1503.76 | 21.53 | 82.33 | 297.17 |
May | 403.17 | 0.50 | 0.48 | 01-MAY-05:00 | 3012.88 | 19.83 | 117.83 | 369.83 | 1149.54 | 19.73 | 56.67 | 325.50 |
June | 418.17 | 0.51 | 0.48 | 01-JUN-05:49 | 3017.05 | 18.98 | 115.00 | 371.33 | 1188.56 | 20.37 | 74.33 | 317.17 |
July | 399.50 | 0.51 | 0.48 | 01-JUL-05:00 | 2644.70 | 19.49 | 115.33 | 360.83 | 1036.51 | 19.35 | 55.50 | 293.17 |
August | 361.83 | 0.51 | 0.48 | 01-AUG-06:19 | 2600.78 | 20.14 | 111.67 | 338.83 | 1444.50 | 21.67 | 83.50 | 279.50 |
September | 350.17 | 0.52 | 0.48 | 01-SEP-06:30 | 1976.74 | 18.08 | 81.17 | 302.67 | 1097.16 | 21.46 | 75.17 | 258.00 |
October | 348.00 | 0.54 | 0.48 | 01-OCT-06:00 | 1937.77 | 18.21 | 87.83 | 267.83 | 1071.23 | 20.84 | 72.00 | 222.50 |
November | 288.50 | 0.52 | 0.48 | 01-NOV-07:40 | 1584.41 | 19.19 | 76.17 | 241.83 | 846.51 | 20.74 | 52.83 | 166.50 |
December | 290.67 | 0.53 | 0.48 | 01-DEC-07:49 | 1795.88 | 19.67 | 85.33 | 229.50 | 1045.52 | 22.79 | 74.00 | 170.33 |
Annual Sum or Average | 4135.50 | 0.52 | 2312.39 | 19.22 | 1139.33 | 3603.83 | 1145.47 | 21.00 | 820.67 | 2930.17 | ||
Minimum of Months | 241.00 | 0.50 | 0.48 | 1584.41 | 18.08 | 65.00 | 229.50 | 846.51 | 19.35 | 52.83 | 159.17 | |
Maximum of Months | 418.17 | 0.54 | 0.48 | 3017.05 | 20.18 | 117.83 | 371.33 | 1503.76 | 22.79 | 83.50 | 325.50 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_3_DAYLCTRL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 309.83 | 0.58 | 0.48 | 01-JAN-10:20 | 377.00 | 12.16 | 0.00 | 180.00 | 264.63 | 15.50 | 0.00 | 46.00 |
February | 241.00 | 0.56 | 0.48 | 01-FEB-12:50 | 469.46 | 13.25 | 0.00 | 195.00 | 305.19 | 16.25 | 0.00 | 79.17 |
March | 344.33 | 0.54 | 0.48 | 01-MAR-08:20 | 540.41 | 14.57 | 0.00 | 281.17 | 340.15 | 17.36 | 0.00 | 180.67 |
April | 380.33 | 0.52 | 0.48 | 01-APR-08:39 | 632.84 | 15.91 | 0.00 | 328.33 | 420.29 | 18.66 | 0.00 | 278.00 |
May | 403.17 | 0.49 | 0.48 | 01-MAY-06:10 | 752.36 | 16.68 | 1.50 | 382.83 | 499.76 | 19.53 | 9.67 | 360.33 |
June | 418.17 | 0.49 | 0.48 | 01-JUN-05:00 | 864.32 | 18.50 | 46.00 | 397.67 | 544.07 | 22.56 | 99.83 | 392.50 |
July | 399.50 | 0.50 | 0.48 | 01-JUL-05:00 | 779.44 | 19.21 | 62.33 | 389.50 | 499.72 | 21.83 | 70.00 | 339.83 |
August | 361.83 | 0.51 | 0.48 | 01-AUG-07:40 | 644.42 | 15.93 | 0.00 | 338.17 | 412.53 | 18.70 | 0.00 | 259.50 |
September | 350.17 | 0.53 | 0.48 | 01-SEP-07:19 | 615.66 | 15.22 | 0.00 | 302.83 | 379.85 | 17.94 | 0.00 | 218.00 |
October | 348.00 | 0.57 | 0.48 | 01-OCT-07:00 | 438.21 | 13.12 | 0.00 | 222.17 | 295.85 | 16.17 | 0.00 | 107.17 |
November | 288.50 | 0.56 | 0.48 | 01-NOV-08:50 | 412.01 | 12.85 | 0.00 | 187.33 | 277.53 | 16.12 | 0.00 | 50.67 |
December | 290.67 | 0.58 | 0.48 | 01-DEC-09:30 | 381.28 | 12.30 | 0.00 | 164.83 | 260.76 | 15.67 | 0.00 | 32.17 |
Annual Sum or Average | 4135.50 | 0.53 | 595.77 | 15.26 | 109.83 | 3369.83 | 387.44 | 18.31 | 179.50 | 2344.00 | ||
Minimum of Months | 241.00 | 0.49 | 0.48 | 377.00 | 12.16 | 0.00 | 164.83 | 260.76 | 15.50 | 0.00 | 32.17 | |
Maximum of Months | 418.17 | 0.58 | 0.48 | 864.32 | 19.21 | 62.33 | 397.67 | 544.07 | 22.56 | 99.83 | 392.50 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_4_DAYLCTRL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 309.83 | 0.55 | 0.48 | 01-JAN-10:09 | 1936.42 | 18.70 | 86.50 | 226.50 | 1141.53 | 21.61 | 74.67 | 174.67 |
February | 241.00 | 0.54 | 0.48 | 01-FEB-12:20 | 2068.38 | 20.08 | 81.00 | 220.17 | 793.67 | 19.33 | 36.50 | 155.17 |
March | 344.33 | 0.53 | 0.48 | 02-MAR-09:20 | 1689.89 | 17.81 | 79.00 | 296.67 | 895.16 | 19.42 | 50.67 | 249.50 |
April | 380.33 | 0.52 | 0.48 | 01-APR-08:50 | 2380.32 | 17.70 | 85.00 | 318.83 | 1381.84 | 19.49 | 55.00 | 288.17 |
May | 403.17 | 0.51 | 0.48 | 01-MAY-07:00 | 2687.92 | 15.35 | 54.50 | 349.33 | 1476.22 | 16.40 | 0.00 | 310.67 |
June | 418.17 | 0.52 | 0.48 | 01-JUN-07:49 | 2707.27 | 11.55 | 0.00 | 353.17 | 1048.68 | 15.97 | 0.00 | 310.67 |
July | 399.50 | 0.52 | 0.48 | 01-JUL-08:20 | 2009.46 | 12.44 | 3.67 | 352.50 | 877.46 | 16.40 | 0.00 | 290.83 |
August | 361.83 | 0.52 | 0.48 | 01-AUG-08:20 | 2079.45 | 15.13 | 49.17 | 326.33 | 1137.31 | 16.49 | 5.00 | 265.00 |
September | 350.17 | 0.52 | 0.48 | 01-SEP-08:09 | 1612.01 | 17.72 | 78.83 | 303.50 | 885.16 | 19.64 | 53.83 | 259.17 |
October | 348.00 | 0.54 | 0.48 | 01-OCT-08:09 | 1928.75 | 17.75 | 87.67 | 262.50 | 1095.39 | 21.00 | 78.50 | 219.50 |
November | 288.50 | 0.54 | 0.48 | 01-NOV-08:50 | 1836.23 | 19.00 | 80.83 | 232.50 | 965.83 | 20.10 | 52.33 | 173.33 |
December | 290.67 | 0.54 | 0.48 | 01-DEC-09:30 | 1547.63 | 18.95 | 80.67 | 217.33 | 807.06 | 19.83 | 49.67 | 167.50 |
Annual Sum or Average | 4135.50 | 0.53 | 2072.76 | 16.53 | 766.83 | 3459.33 | 1058.85 | 18.62 | 456.17 | 2864.17 | ||
Minimum of Months | 241.00 | 0.51 | 0.48 | 1547.63 | 11.55 | 0.00 | 217.33 | 793.67 | 15.97 | 0.00 | 155.17 | |
Maximum of Months | 418.17 | 0.55 | 0.48 | 2707.27 | 20.08 | 87.67 | 353.17 | 1476.22 | 21.61 | 78.50 | 310.67 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_1_DAYLCTRL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 309.83 | 0.51 | 0.48 | 01-JAN-08:09 | 7947.68 | 34.50 | 270.50 | 278.50 | 1999.90 | 25.91 | 145.33 | 283.83 |
February | 241.00 | 0.51 | 0.48 | 01-FEB-07:49 | 7301.69 | 35.62 | 233.67 | 259.33 | 1053.48 | 19.48 | 37.50 | 212.50 |
March | 344.33 | 0.52 | 0.48 | 01-MAR-07:30 | 1265.87 | 12.91 | 2.33 | 319.83 | 738.44 | 16.96 | 1.83 | 270.83 |
April | 380.33 | 0.53 | 0.48 | 01-APR-08:20 | 968.70 | 13.00 | 0.00 | 321.17 | 613.62 | 17.03 | 0.00 | 281.67 |
May | 403.17 | 0.52 | 0.48 | 01-MAY-07:40 | 768.25 | 12.72 | 0.00 | 340.83 | 489.93 | 16.79 | 0.00 | 283.33 |
June | 418.17 | 0.53 | 0.48 | 01-JUN-07:40 | 636.27 | 11.92 | 0.00 | 342.17 | 418.78 | 16.04 | 0.00 | 258.00 |
July | 399.50 | 0.53 | 0.48 | 01-JUL-08:09 | 742.96 | 12.23 | 0.00 | 342.67 | 453.73 | 16.26 | 0.00 | 253.17 |
August | 361.83 | 0.52 | 0.48 | 01-AUG-07:00 | 852.27 | 12.59 | 0.00 | 322.00 | 523.47 | 16.65 | 0.00 | 257.00 |
September | 350.17 | 0.52 | 0.48 | 01-SEP-07:10 | 1232.87 | 13.56 | 10.83 | 308.33 | 689.56 | 16.96 | 0.00 | 270.33 |
October | 348.00 | 0.51 | 0.48 | 01-OCT-07:19 | 2684.12 | 20.29 | 137.17 | 313.00 | 903.25 | 16.75 | 13.17 | 290.33 |
November | 288.50 | 0.50 | 0.48 | 01-NOV-07:40 | 7617.05 | 35.38 | 268.33 | 278.50 | 1326.59 | 22.01 | 88.83 | 262.17 |
December | 290.67 | 0.50 | 0.48 | 01-DEC-07:49 | 7364.15 | 35.21 | 262.50 | 269.50 | 1829.74 | 24.92 | 125.50 | 269.17 |
Annual Sum or Average | 4135.50 | 0.52 | 2880.25 | 19.46 | 1185.33 | 3695.83 | 864.43 | 18.47 | 412.17 | 3192.33 | ||
Minimum of Months | 241.00 | 0.50 | 0.48 | 636.27 | 11.92 | 0.00 | 259.33 | 418.78 | 16.04 | 0.00 | 212.50 | |
Maximum of Months | 418.17 | 0.53 | 0.48 | 7947.68 | 35.62 | 270.50 | 342.67 | 1999.90 | 25.91 | 145.33 | 290.33 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_2_DAYLCTRL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 309.83 | 0.54 | 0.48 | 01-JAN-07:00 | 1770.14 | 18.78 | 86.50 | 242.33 | 918.23 | 20.03 | 56.33 | 178.67 |
February | 241.00 | 0.53 | 0.48 | 01-FEB-07:00 | 2089.67 | 18.56 | 65.00 | 230.50 | 1235.82 | 22.56 | 62.83 | 156.17 |
March | 344.33 | 0.53 | 0.48 | 01-MAR-07:30 | 1803.55 | 18.02 | 85.17 | 295.67 | 913.29 | 19.68 | 56.83 | 249.00 |
April | 380.33 | 0.51 | 0.48 | 01-APR-06:40 | 2443.28 | 17.50 | 84.50 | 334.67 | 1448.92 | 21.36 | 82.33 | 291.83 |
May | 403.17 | 0.50 | 0.48 | 01-MAY-06:10 | 2937.25 | 19.43 | 117.83 | 366.50 | 1092.20 | 19.56 | 56.67 | 321.33 |
June | 418.17 | 0.51 | 0.48 | 01-JUN-05:49 | 2954.32 | 18.58 | 115.00 | 364.67 | 1133.85 | 20.22 | 74.33 | 314.33 |
July | 399.50 | 0.51 | 0.48 | 01-JUL-05:00 | 2579.70 | 19.10 | 115.33 | 356.83 | 984.62 | 19.19 | 55.50 | 290.00 |
August | 361.83 | 0.51 | 0.48 | 01-AUG-06:19 | 2528.33 | 19.75 | 111.67 | 335.83 | 1392.56 | 21.51 | 83.50 | 274.83 |
September | 350.17 | 0.53 | 0.48 | 01-SEP-06:40 | 1920.99 | 17.65 | 81.17 | 299.67 | 1047.85 | 21.10 | 73.17 | 254.00 |
October | 348.00 | 0.54 | 0.48 | 01-OCT-06:00 | 1880.83 | 17.79 | 87.83 | 264.67 | 963.14 | 19.23 | 56.83 | 215.83 |
November | 288.50 | 0.52 | 0.48 | 01-NOV-07:40 | 1537.94 | 18.76 | 76.17 | 236.67 | 809.14 | 20.53 | 52.83 | 160.83 |
December | 290.67 | 0.53 | 0.48 | 01-DEC-07:49 | 1750.39 | 19.23 | 85.33 | 223.83 | 991.06 | 22.18 | 70.67 | 164.67 |
Annual Sum or Average | 4135.50 | 0.52 | 2236.02 | 18.60 | 1111.50 | 3551.83 | 1084.07 | 20.50 | 781.83 | 2871.50 | ||
Minimum of Months | 241.00 | 0.50 | 0.48 | 1537.94 | 17.50 | 65.00 | 223.83 | 809.14 | 19.19 | 52.83 | 156.17 | |
Maximum of Months | 418.17 | 0.54 | 0.48 | 2954.32 | 19.75 | 117.83 | 366.50 | 1448.92 | 22.56 | 83.50 | 321.33 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_3_DAYLCTRL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 309.83 | 0.59 | 0.48 | 01-JAN-10:30 | 360.93 | 8.84 | 0.00 | 163.67 | 256.66 | 13.25 | 0.00 | 34.00 |
February | 241.00 | 0.56 | 0.48 | 01-FEB-12:00 | 450.28 | 9.94 | 0.00 | 184.50 | 295.45 | 14.09 | 0.00 | 69.17 |
March | 344.33 | 0.54 | 0.48 | 01-MAR-08:30 | 518.58 | 11.30 | 0.00 | 275.00 | 328.93 | 15.36 | 0.00 | 170.17 |
April | 380.33 | 0.52 | 0.48 | 01-APR-08:50 | 607.61 | 12.89 | 0.00 | 324.00 | 407.68 | 17.00 | 0.00 | 266.50 |
May | 403.17 | 0.49 | 0.48 | 01-MAY-06:10 | 722.26 | 13.37 | 1.50 | 382.50 | 483.73 | 17.61 | 2.67 | 352.17 |
June | 418.17 | 0.49 | 0.48 | 01-JUN-05:00 | 831.53 | 15.32 | 44.67 | 396.00 | 525.92 | 20.79 | 81.50 | 389.83 |
July | 399.50 | 0.50 | 0.48 | 01-JUL-05:00 | 734.45 | 14.79 | 32.50 | 385.50 | 481.72 | 19.96 | 62.83 | 330.00 |
August | 361.83 | 0.51 | 0.48 | 01-AUG-07:49 | 618.60 | 12.62 | 0.00 | 334.17 | 399.30 | 16.79 | 0.00 | 244.17 |
September | 350.17 | 0.53 | 0.48 | 01-SEP-07:19 | 590.25 | 11.97 | 0.00 | 299.50 | 366.60 | 15.94 | 0.00 | 205.17 |
October | 348.00 | 0.57 | 0.48 | 01-OCT-07:00 | 420.83 | 9.88 | 0.00 | 211.50 | 287.22 | 14.12 | 0.00 | 96.00 |
November | 288.50 | 0.57 | 0.48 | 01-NOV-08:50 | 394.84 | 9.40 | 0.00 | 175.33 | 268.91 | 13.83 | 0.00 | 41.83 |
December | 290.67 | 0.58 | 0.48 | 01-DEC-10:50 | 364.80 | 8.84 | 0.00 | 149.67 | 252.46 | 13.30 | 0.00 | 23.17 |
Annual Sum or Average | 4135.50 | 0.54 | 570.49 | 11.88 | 78.67 | 3281.33 | 374.85 | 16.31 | 147.00 | 2222.17 | ||
Minimum of Months | 241.00 | 0.49 | 0.48 | 360.93 | 8.84 | 0.00 | 149.67 | 252.46 | 13.25 | 0.00 | 23.17 | |
Maximum of Months | 418.17 | 0.59 | 0.48 | 831.53 | 15.32 | 44.67 | 396.00 | 525.92 | 20.79 | 81.50 | 389.83 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_4_DAYLCTRL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 309.83 | 0.55 | 0.48 | 01-JAN-10:20 | 1884.59 | 18.36 | 86.50 | 223.33 | 1098.93 | 21.52 | 74.67 | 170.33 |
February | 241.00 | 0.54 | 0.48 | 01-FEB-12:30 | 2015.91 | 19.75 | 81.00 | 216.50 | 755.30 | 19.22 | 36.50 | 151.83 |
March | 344.33 | 0.53 | 0.48 | 02-MAR-09:30 | 1637.34 | 17.43 | 79.00 | 293.67 | 852.78 | 19.28 | 50.67 | 245.17 |
April | 380.33 | 0.52 | 0.48 | 01-APR-08:50 | 2308.31 | 17.30 | 85.00 | 314.50 | 1325.53 | 19.33 | 55.00 | 284.33 |
May | 403.17 | 0.52 | 0.48 | 01-MAY-07:00 | 2610.60 | 14.92 | 54.50 | 346.83 | 1422.01 | 16.23 | 0.00 | 307.33 |
June | 418.17 | 0.52 | 0.48 | 01-JUN-07:49 | 2641.49 | 11.10 | 0.00 | 349.00 | 994.76 | 15.79 | 0.00 | 308.00 |
July | 399.50 | 0.52 | 0.48 | 01-JUL-08:30 | 1944.23 | 11.97 | 3.67 | 347.83 | 835.54 | 16.20 | 0.00 | 286.00 |
August | 361.83 | 0.52 | 0.48 | 01-AUG-08:30 | 1933.19 | 14.68 | 49.17 | 318.67 | 1087.43 | 16.31 | 5.00 | 261.00 |
September | 350.17 | 0.53 | 0.48 | 01-SEP-08:09 | 1561.23 | 17.34 | 78.67 | 299.83 | 823.82 | 19.49 | 53.83 | 252.83 |
October | 348.00 | 0.54 | 0.48 | 01-OCT-08:20 | 1876.74 | 17.38 | 87.67 | 259.00 | 1054.33 | 20.88 | 78.50 | 216.17 |
November | 288.50 | 0.54 | 0.48 | 01-NOV-08:00 | 1779.75 | 18.64 | 80.83 | 229.00 | 921.34 | 19.98 | 52.33 | 170.00 |
December | 290.67 | 0.55 | 0.48 | 01-DEC-09:30 | 1499.90 | 18.61 | 80.67 | 214.50 | 768.65 | 19.73 | 49.67 | 163.00 |
Annual Sum or Average | 4135.50 | 0.53 | 2005.56 | 16.13 | 766.67 | 3412.67 | 1011.11 | 18.47 | 456.17 | 2816.00 | ||
Minimum of Months | 241.00 | 0.52 | 0.48 | 1499.90 | 11.10 | 0.00 | 214.50 | 755.30 | 15.79 | 0.00 | 151.83 | |
Maximum of Months | 418.17 | 0.55 | 0.48 | 2641.49 | 19.75 | 87.67 | 349.00 | 1422.01 | 21.52 | 78.50 | 308.00 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_1_DAYLCTRL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 309.83 | 0.51 | 0.48 | 01-JAN-08:09 | 7947.70 | 34.50 | 270.50 | 278.67 | 1999.85 | 25.91 | 145.33 | 283.83 |
February | 241.00 | 0.51 | 0.48 | 01-FEB-07:49 | 7301.66 | 35.62 | 233.67 | 259.33 | 1053.42 | 19.48 | 37.50 | 212.50 |
March | 344.33 | 0.52 | 0.48 | 01-MAR-07:30 | 1265.83 | 12.91 | 2.33 | 319.83 | 738.40 | 16.96 | 1.83 | 270.83 |
April | 380.33 | 0.53 | 0.48 | 01-APR-08:20 | 968.68 | 13.00 | 0.00 | 321.17 | 613.59 | 17.03 | 0.00 | 281.50 |
May | 403.17 | 0.52 | 0.48 | 01-MAY-07:40 | 768.24 | 12.73 | 0.00 | 340.83 | 489.91 | 16.79 | 0.00 | 283.33 |
June | 418.17 | 0.53 | 0.48 | 01-JUN-07:40 | 636.27 | 11.92 | 0.00 | 342.17 | 418.76 | 16.04 | 0.00 | 258.00 |
July | 399.50 | 0.53 | 0.48 | 01-JUL-08:09 | 742.94 | 12.23 | 0.00 | 342.67 | 453.71 | 16.26 | 0.00 | 253.00 |
August | 361.83 | 0.52 | 0.48 | 01-AUG-07:00 | 852.25 | 12.59 | 0.00 | 322.00 | 523.44 | 16.65 | 0.00 | 257.00 |
September | 350.17 | 0.52 | 0.48 | 01-SEP-07:10 | 1232.82 | 13.56 | 10.83 | 308.33 | 689.52 | 16.96 | 0.00 | 270.33 |
October | 348.00 | 0.51 | 0.48 | 01-OCT-07:19 | 2684.09 | 20.29 | 137.17 | 313.00 | 903.21 | 16.75 | 13.17 | 290.33 |
November | 288.50 | 0.50 | 0.48 | 01-NOV-07:40 | 7617.05 | 35.39 | 268.33 | 278.50 | 1326.54 | 22.01 | 88.83 | 262.17 |
December | 290.67 | 0.50 | 0.48 | 01-DEC-07:49 | 7364.17 | 35.21 | 262.50 | 269.50 | 1829.69 | 24.92 | 125.50 | 269.17 |
Annual Sum or Average | 4135.50 | 0.52 | 2880.24 | 19.46 | 1185.33 | 3696.00 | 864.39 | 18.47 | 412.17 | 3192.00 | ||
Minimum of Months | 241.00 | 0.50 | 0.48 | 636.27 | 11.92 | 0.00 | 259.33 | 418.76 | 16.04 | 0.00 | 212.50 | |
Maximum of Months | 418.17 | 0.53 | 0.48 | 7947.70 | 35.62 | 270.50 | 342.67 | 1999.85 | 25.91 | 145.33 | 290.33 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_2_DAYLCTRL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 309.83 | 0.54 | 0.48 | 01-JAN-07:00 | 1770.15 | 18.78 | 86.50 | 242.33 | 918.21 | 20.03 | 56.33 | 178.67 |
February | 241.00 | 0.53 | 0.48 | 01-FEB-07:00 | 2089.67 | 18.56 | 65.00 | 230.50 | 1235.80 | 22.56 | 62.83 | 156.17 |
March | 344.33 | 0.53 | 0.48 | 01-MAR-07:30 | 1803.55 | 18.02 | 85.17 | 295.67 | 913.26 | 19.68 | 56.83 | 249.00 |
April | 380.33 | 0.51 | 0.48 | 01-APR-06:40 | 2443.29 | 17.51 | 84.50 | 334.67 | 1448.89 | 21.36 | 82.33 | 291.83 |
May | 403.17 | 0.50 | 0.48 | 01-MAY-06:10 | 2937.26 | 19.44 | 117.83 | 366.50 | 1092.17 | 19.56 | 56.67 | 321.33 |
June | 418.17 | 0.51 | 0.48 | 01-JUN-05:49 | 2954.32 | 18.58 | 115.00 | 364.67 | 1133.83 | 20.22 | 74.33 | 314.33 |
July | 399.50 | 0.51 | 0.48 | 01-JUL-05:00 | 2579.70 | 19.11 | 115.33 | 356.83 | 984.58 | 19.19 | 55.50 | 290.00 |
August | 361.83 | 0.51 | 0.48 | 01-AUG-06:19 | 2528.33 | 19.75 | 111.67 | 335.83 | 1392.53 | 21.51 | 83.50 | 274.83 |
September | 350.17 | 0.53 | 0.48 | 01-SEP-06:40 | 1920.98 | 17.65 | 81.17 | 299.67 | 1047.81 | 21.10 | 73.17 | 254.00 |
October | 348.00 | 0.54 | 0.48 | 01-OCT-06:00 | 1880.84 | 17.79 | 87.83 | 264.67 | 963.11 | 19.23 | 56.83 | 215.83 |
November | 288.50 | 0.52 | 0.48 | 01-NOV-07:40 | 1537.95 | 18.76 | 76.17 | 236.67 | 809.12 | 20.53 | 52.83 | 160.83 |
December | 290.67 | 0.53 | 0.48 | 01-DEC-07:49 | 1750.40 | 19.23 | 85.33 | 223.83 | 991.04 | 22.18 | 70.67 | 164.67 |
Annual Sum or Average | 4135.50 | 0.52 | 2236.02 | 18.60 | 1111.50 | 3551.83 | 1084.05 | 20.50 | 781.83 | 2871.50 | ||
Minimum of Months | 241.00 | 0.50 | 0.48 | 1537.95 | 17.51 | 65.00 | 223.83 | 809.12 | 19.19 | 52.83 | 156.17 | |
Maximum of Months | 418.17 | 0.54 | 0.48 | 2954.32 | 19.75 | 117.83 | 366.50 | 1448.89 | 22.56 | 83.50 | 321.33 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_3_DAYLCTRL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 309.83 | 0.59 | 0.48 | 01-JAN-10:30 | 360.94 | 8.85 | 0.00 | 163.67 | 256.65 | 13.25 | 0.00 | 34.00 |
February | 241.00 | 0.56 | 0.48 | 01-FEB-12:00 | 450.28 | 9.94 | 0.00 | 184.50 | 295.44 | 14.10 | 0.00 | 69.17 |
March | 344.33 | 0.54 | 0.48 | 01-MAR-08:30 | 518.58 | 11.30 | 0.00 | 275.00 | 328.91 | 15.36 | 0.00 | 170.17 |
April | 380.33 | 0.52 | 0.48 | 01-APR-08:50 | 607.62 | 12.89 | 0.00 | 324.00 | 407.66 | 17.00 | 0.00 | 266.50 |
May | 403.17 | 0.49 | 0.48 | 01-MAY-06:10 | 722.26 | 13.37 | 1.50 | 382.50 | 483.71 | 17.61 | 2.67 | 352.17 |
June | 418.17 | 0.49 | 0.48 | 01-JUN-05:00 | 831.53 | 15.32 | 44.67 | 396.00 | 525.90 | 20.79 | 81.50 | 389.83 |
July | 399.50 | 0.50 | 0.48 | 01-JUL-05:00 | 734.44 | 14.79 | 32.50 | 385.50 | 481.70 | 19.96 | 62.83 | 330.00 |
August | 361.83 | 0.51 | 0.48 | 01-AUG-07:49 | 618.60 | 12.62 | 0.00 | 334.17 | 399.28 | 16.79 | 0.00 | 244.17 |
September | 350.17 | 0.53 | 0.48 | 01-SEP-07:19 | 590.24 | 11.97 | 0.00 | 299.50 | 366.58 | 15.94 | 0.00 | 205.17 |
October | 348.00 | 0.57 | 0.48 | 01-OCT-07:00 | 420.83 | 9.88 | 0.00 | 211.67 | 287.21 | 14.12 | 0.00 | 96.00 |
November | 288.50 | 0.57 | 0.48 | 01-NOV-08:50 | 394.85 | 9.40 | 0.00 | 175.33 | 268.90 | 13.83 | 0.00 | 41.83 |
December | 290.67 | 0.58 | 0.48 | 01-DEC-10:50 | 364.81 | 8.85 | 0.00 | 149.67 | 252.45 | 13.30 | 0.00 | 23.17 |
Annual Sum or Average | 4135.50 | 0.54 | 570.49 | 11.88 | 78.67 | 3281.50 | 374.84 | 16.31 | 147.00 | 2222.17 | ||
Minimum of Months | 241.00 | 0.49 | 0.48 | 360.94 | 8.85 | 0.00 | 149.67 | 252.45 | 13.25 | 0.00 | 23.17 | |
Maximum of Months | 418.17 | 0.59 | 0.48 | 831.53 | 15.32 | 44.67 | 396.00 | 525.90 | 20.79 | 81.50 | 389.83 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_4_DAYLCTRL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 309.83 | 0.55 | 0.48 | 01-JAN-10:20 | 1884.60 | 18.36 | 86.50 | 223.33 | 1098.91 | 21.52 | 74.67 | 170.33 |
February | 241.00 | 0.54 | 0.48 | 01-FEB-12:30 | 2015.91 | 19.75 | 81.00 | 216.50 | 755.27 | 19.22 | 36.50 | 151.83 |
March | 344.33 | 0.53 | 0.48 | 02-MAR-09:30 | 1637.33 | 17.43 | 79.00 | 293.67 | 852.75 | 19.28 | 50.67 | 245.17 |
April | 380.33 | 0.52 | 0.48 | 01-APR-08:50 | 2308.31 | 17.31 | 85.00 | 314.50 | 1325.50 | 19.33 | 55.00 | 284.33 |
May | 403.17 | 0.52 | 0.48 | 01-MAY-07:00 | 2610.61 | 14.93 | 54.50 | 346.83 | 1421.98 | 16.23 | 0.00 | 307.17 |
June | 418.17 | 0.52 | 0.48 | 01-JUN-07:49 | 2641.50 | 11.11 | 0.00 | 349.17 | 994.74 | 15.79 | 0.00 | 308.00 |
July | 399.50 | 0.52 | 0.48 | 01-JUL-08:30 | 1944.22 | 11.97 | 3.67 | 347.83 | 835.50 | 16.20 | 0.00 | 286.00 |
August | 361.83 | 0.52 | 0.48 | 01-AUG-08:30 | 1933.18 | 14.69 | 49.17 | 318.67 | 1087.40 | 16.31 | 5.00 | 261.00 |
September | 350.17 | 0.53 | 0.48 | 01-SEP-08:09 | 1561.22 | 17.34 | 78.67 | 299.83 | 823.78 | 19.49 | 53.83 | 252.83 |
October | 348.00 | 0.54 | 0.48 | 01-OCT-08:20 | 1876.74 | 17.38 | 87.67 | 259.00 | 1054.31 | 20.88 | 78.50 | 216.17 |
November | 288.50 | 0.54 | 0.48 | 01-NOV-08:00 | 1779.77 | 18.64 | 80.83 | 229.00 | 921.32 | 19.98 | 52.33 | 170.00 |
December | 290.67 | 0.55 | 0.48 | 01-DEC-09:30 | 1499.92 | 18.61 | 80.67 | 214.50 | 768.63 | 19.73 | 49.67 | 163.00 |
Annual Sum or Average | 4135.50 | 0.53 | 2005.56 | 16.13 | 766.67 | 3412.83 | 1011.08 | 18.47 | 456.17 | 2815.83 | ||
Minimum of Months | 241.00 | 0.52 | 0.48 | 1499.92 | 11.11 | 0.00 | 214.50 | 755.27 | 15.79 | 0.00 | 151.83 | |
Maximum of Months | 418.17 | 0.55 | 0.48 | 2641.50 | 19.75 | 87.67 | 349.17 | 1421.98 | 21.52 | 78.50 | 308.00 |
Report: CoilReportMonthly
For: CORE_BOTTOM VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.589991E+09 | 7939.44 | 02-JAN-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.660059E+09 | 7939.44 | 01-FEB-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.732068E+09 | 7939.44 | 01-MAR-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.136984E+09 | 7939.44 | 07-APR-06:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 7993040.07 | 6981.51 | 01-MAY-06:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.247036E+09 | 7939.44 | 12-OCT-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.343825E+09 | 7939.44 | 06-NOV-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.704360E+09 | 7939.44 | 01-DEC-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.342232E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.732068E+09 | 7939.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 6031791.48 | 5266.07 | 02-JAN-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 5415960.09 | 5266.07 | 13-FEB-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 3296235.46 | 5266.07 | 27-MAR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6631605.91 | 5266.07 | 06-DEC-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 21375592.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 6631605.91 | 5266.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 27209606.79 | 7884.40 | 02-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 31040073.17 | 7884.40 | 13-FEB-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 23991092.68 | 7884.40 | 27-MAR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 36998852.98 | 7884.40 | 05-DEC-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.119240E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 36998852.98 | 7884.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 7183887.96 | 5229.76 | 02-JAN-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 15822094.63 | 5229.76 | 08-FEB-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 6669060.33 | 5229.76 | 27-MAR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 19053915.67 | 5229.76 | 06-DEC-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 48728958.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 19053915.67 | 5229.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CORE_MID VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 145910.85 | 1215.92 | 02-JAN-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 145910.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 145910.85 | 1215.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 9561119.69 | 9391.00 | 02-JAN-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 8506373.39 | 9391.00 | 13-FEB-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 5965705.29 | 9391.00 | 27-MAR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 224030.89 | 2613.69 | 24-NOV-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 45928259.38 | 9391.00 | 05-DEC-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 70185488.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 45928259.38 | 9391.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 15916907.56 | 6204.11 | 02-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 15960591.02 | 6204.11 | 08-FEB-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 8744025.00 | 6204.11 | 27-MAR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 2112379.57 | 6204.11 | 24-NOV-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 67584166.46 | 6204.11 | 04-DEC-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.110318E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 67584166.46 | 6204.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 28263954.93 | 9349.74 | 02-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 24976350.56 | 9349.74 | 13-FEB-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 12203345.64 | 9349.74 | 27-MAR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 5581476.67 | 9349.74 | 24-NOV-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.126193E+09 | 9349.74 | 04-DEC-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.197218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.126193E+09 | 9349.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 24903665.63 | 6168.84 | 02-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 31144368.67 | 6168.84 | 08-FEB-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 13968813.86 | 6168.84 | 27-MAR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 5756826.84 | 6168.84 | 24-NOV-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.119857E+09 | 6168.84 | 04-DEC-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.195630E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.119857E+09 | 6168.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CORE_TOP VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 69168796.66 | 29302.32 | 02-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 40608416.16 | 29302.32 | 13-FEB-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 10187407.13 | 29302.32 | 27-MAR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 9199901.04 | 27944.85 | 24-NOV-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.232995E+09 | 29302.32 | 05-DEC-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.362159E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.232995E+09 | 29302.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.106517E+09 | 12493.82 | 02-JAN-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.168529E+09 | 12488.51 | 14-FEB-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.114844E+09 | 12369.81 | 30-MAR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 15457977.26 | 10123.54 | 26-OCT-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 54407692.29 | 12394.60 | 27-NOV-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.359780E+09 | 12401.40 | 18-DEC-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.819536E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.359780E+09 | 12493.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.118468E+09 | 8259.18 | 02-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.150201E+09 | 8259.18 | 01-FEB-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 75533341.42 | 8259.18 | 13-MAR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 143360.13 | 238.93 | 01-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 19390279.01 | 7805.44 | 26-OCT-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 59669771.30 | 8259.18 | 24-NOV-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.359453E+09 | 8259.18 | 04-DEC-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.782858E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.359453E+09 | 8259.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.236764E+09 | 11239.82 | 02-JAN-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.263737E+09 | 11266.21 | 13-FEB-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.151488E+09 | 11210.07 | 13-MAR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 28174067.58 | 11139.69 | 26-OCT-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.142968E+09 | 11153.06 | 07-NOV-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.753217E+09 | 11217.52 | 05-DEC-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.157635E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.753217E+09 | 11266.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.207954E+09 | 8223.72 | 02-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.260488E+09 | 8223.72 | 01-FEB-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.145514E+09 | 8223.72 | 13-MAR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 1374016.55 | 1047.91 | 21-APR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 35664855.53 | 8223.72 | 25-OCT-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.134878E+09 | 8223.72 | 24-NOV-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.591446E+09 | 8223.72 | 04-DEC-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.137732E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.591446E+09 | 8223.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_BOT HEATING COIL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 9789022.83 | 2084.37 | 02-JAN-08:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 5991151.21 | 1104.76 | 28-FEB-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 47430107.35 | 4675.23 | 27-MAR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 46017.42 | 536.87 | 25-OCT-06:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 2652040.82 | 1513.69 | 24-NOV-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.224863E+09 | 6935.25 | 06-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.290772E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.224863E+09 | 6935.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_MID HEATING COIL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 54479709.63 | 3818.03 | 02-JAN-07:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 82674872.70 | 2913.16 | 28-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.130385E+09 | 6186.66 | 27-MAR-06:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 12344841.43 | 2587.11 | 25-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 30449561.27 | 3996.48 | 24-NOV-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.484353E+09 | 8430.90 | 06-DEC-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.794686E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.484353E+09 | 8430.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_TOP HEATING COIL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.135292E+09 | 5416.25 | 02-JAN-07:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.200552E+09 | 4735.61 | 28-FEB-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.234565E+09 | 8173.56 | 27-MAR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 148483.02 | 260.82 | 21-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 45558874.97 | 4208.68 | 25-OCT-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 85476782.58 | 6129.98 | 24-NOV-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.776742E+09 | 10927.58 | 06-DEC-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.147834E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.776742E+09 | 10927.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_BOT COOLING COIL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.171135E+11 | 0.169873E+11 | 46951.43 | 31-JAN-16:40 | 46951.43 | 0.00 |
February | 0.00 | 0.00 | 0.376141E+10 | 0.329693E+10 | 20795.11 | 22-FEB-16:10 | 20795.11 | 0.00 |
March | 0.00 | 0.00 | 0.162652E+11 | 0.158911E+11 | 45601.40 | 20-MAR-15:10 | 45601.40 | 0.00 |
April | 0.00 | 0.00 | 0.449031E+11 | 0.448254E+11 | 62685.46 | 14-APR-16:00 | 62685.46 | 0.00 |
May | 0.00 | 0.00 | 0.595821E+11 | 0.595380E+11 | 66324.15 | 31-MAY-16:00 | 66324.15 | 0.00 |
June | 0.00 | 0.00 | 0.794262E+11 | 0.791999E+11 | 84815.24 | 28-JUN-06:03 | 84815.24 | 0.00 |
July | 0.00 | 0.00 | 0.821151E+11 | 0.760245E+11 | 121407.26 | 15-JUL-06:03 | 54362.80 | 0.00 |
August | 0.00 | 0.00 | 0.860394E+11 | 0.790714E+11 | 119618.46 | 01-AUG-04:03 | 62168.45 | 0.00 |
September | 0.00 | 0.00 | 0.748346E+11 | 0.678308E+11 | 119420.21 | 05-SEP-07:20 | 51696.50 | 0.00 |
October | 0.00 | 0.00 | 0.424511E+11 | 0.411307E+11 | 106702.67 | 03-OCT-04:03 | 53313.81 | 0.00 |
November | 0.00 | 0.00 | 0.194380E+11 | 0.182279E+11 | 53360.27 | 01-NOV-16:00 | 53360.27 | 0.00 |
December | 0.00 | 0.00 | 0.814301E+10 | 0.812093E+10 | 40963.83 | 22-DEC-16:30 | 40963.83 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.534073E+12 | 0.510145E+12 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.376141E+10 | 0.329693E+10 | 20795.11 | 20795.11 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.860394E+11 | 0.791999E+11 | 121407.26 | 84815.24 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_MID COOLING COIL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.140634E+11 | 0.139370E+11 | 38784.44 | 31-JAN-16:30 | 38784.44 | 0.00 |
February | 0.00 | 0.00 | 0.320158E+10 | 0.274274E+10 | 19067.48 | 22-FEB-16:00 | 19067.48 | 0.00 |
March | 0.00 | 0.00 | 0.138614E+11 | 0.134559E+11 | 41642.33 | 16-MAR-15:30 | 41642.33 | 0.00 |
April | 0.00 | 0.00 | 0.403849E+11 | 0.403314E+11 | 58974.46 | 14-APR-15:30 | 58974.46 | 0.00 |
May | 0.00 | 0.00 | 0.539389E+11 | 0.539161E+11 | 59931.26 | 08-MAY-16:00 | 59931.26 | 0.00 |
June | 0.00 | 0.00 | 0.729318E+11 | 0.728068E+11 | 74438.28 | 29-JUN-06:03 | 74438.28 | 0.00 |
July | 0.00 | 0.00 | 0.710030E+11 | 0.665683E+11 | 110025.16 | 14-JUL-05:03 | 43988.48 | 0.00 |
August | 0.00 | 0.00 | 0.723462E+11 | 0.674519E+11 | 106797.69 | 01-AUG-04:03 | 54072.41 | 0.00 |
September | 0.00 | 0.00 | 0.606259E+11 | 0.555611E+11 | 106737.62 | 02-SEP-05:03 | 58787.32 | 0.00 |
October | 0.00 | 0.00 | 0.337297E+11 | 0.326818E+11 | 72055.67 | 02-OCT-04:02 | 71301.50 | 0.00 |
November | 0.00 | 0.00 | 0.146064E+11 | 0.136259E+11 | 45378.52 | 01-NOV-15:30 | 45378.52 | 0.00 |
December | 0.00 | 0.00 | 0.650936E+10 | 0.647671E+10 | 31745.75 | 25-DEC-16:33 | 31745.75 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.457202E+12 | 0.439556E+12 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.320158E+10 | 0.274274E+10 | 19067.48 | 19067.48 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.729318E+11 | 0.728068E+11 | 110025.16 | 74438.28 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_TOP COOLING COIL
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.137772E+11 | 0.136036E+11 | 42988.57 | 31-JAN-16:30 | 42988.57 | 0.00 |
February | 0.00 | 0.00 | 0.321634E+10 | 0.266845E+10 | 19121.38 | 22-FEB-16:00 | 19121.38 | 0.00 |
March | 0.00 | 0.00 | 0.145189E+11 | 0.139214E+11 | 48368.81 | 16-MAR-15:40 | 48368.81 | 0.00 |
April | 0.00 | 0.00 | 0.448235E+11 | 0.447233E+11 | 71276.57 | 14-APR-15:30 | 71276.57 | 0.00 |
May | 0.00 | 0.00 | 0.601765E+11 | 0.601371E+11 | 71463.96 | 15-MAY-15:20 | 71463.96 | 0.00 |
June | 0.00 | 0.00 | 0.827609E+11 | 0.825899E+11 | 86503.25 | 28-JUN-15:00 | 86503.25 | 0.00 |
July | 0.00 | 0.00 | 0.794066E+11 | 0.748448E+11 | 126393.79 | 14-JUL-05:03 | 50373.66 | 0.00 |
August | 0.00 | 0.00 | 0.796241E+11 | 0.746314E+11 | 122686.16 | 01-AUG-04:03 | 59782.96 | 0.00 |
September | 0.00 | 0.00 | 0.652116E+11 | 0.600968E+11 | 103545.32 | 08-SEP-05:03 | 60205.15 | 0.00 |
October | 0.00 | 0.00 | 0.351002E+11 | 0.339806E+11 | 82522.36 | 02-OCT-04:02 | 82522.36 | 0.00 |
November | 0.00 | 0.00 | 0.142315E+11 | 0.132130E+11 | 51662.07 | 01-NOV-15:30 | 51662.07 | 0.00 |
December | 0.00 | 0.00 | 0.623849E+10 | 0.618692E+10 | 35127.12 | 25-DEC-16:33 | 35127.12 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.499086E+12 | 0.480597E+12 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.321634E+10 | 0.266845E+10 | 19121.38 | 19121.38 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.827609E+11 | 0.825899E+11 | 126393.79 | 86503.25 | 0.00 |
Report: PlantLoopDemandReportMonthly
For: SWHSYS1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 1576.52 | 5410.91 | 12-JAN-12:10 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 1571.50 | 5436.48 | 02-FEB-12:09 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 1598.72 | 5262.45 | 01-MAR-12:15 |
April | 0.00 | 0.00 | 01-APR-00:10 | 1387.58 | 4881.43 | 03-APR-11:20 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 1318.09 | 4496.67 | 01-MAY-11:40 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 1248.63 | 4106.24 | 01-JUN-11:20 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 1103.07 | 3848.55 | 03-JUL-11:13 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 1224.55 | 3965.34 | 31-AUG-11:10 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 1217.72 | 4274.26 | 29-SEP-11:10 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 1324.07 | 4690.96 | 31-OCT-11:40 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 1460.88 | 5078.02 | 30-NOV-12:20 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 1492.33 | 5332.13 | 29-DEC-12:30 |
Annual Sum or Average | 0.00 | 1375.90 | ||||
Minimum of Months | 0.00 | 0.00 | 1103.07 | 3848.55 | ||
Maximum of Months | 0.00 | 0.00 | 1598.72 | 5436.48 |
Report: FanReportMonthly
For: PACU_VAV_BOT FAN
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.249725E+10 | 0.37 | 4319.54 | 19-JAN-17:00 | 1.07 |
February | 0.173149E+10 | 0.32 | 4205.48 | 01-FEB-06:02 | 1.05 |
March | 0.244690E+10 | 0.37 | 4717.89 | 20-MAR-15:10 | 1.12 |
April | 0.415220E+10 | 0.49 | 7030.31 | 17-APR-15:10 | 1.43 |
May | 0.534755E+10 | 0.56 | 8331.50 | 31-MAY-16:00 | 1.60 |
June | 0.666182E+10 | 0.66 | 11546.64 | 05-JUN-06:03 | 1.96 |
July | 0.634553E+10 | 0.62 | 11546.64 | 05-JUL-04:02 | 1.96 |
August | 0.646298E+10 | 0.63 | 11546.64 | 01-AUG-04:03 | 1.94 |
September | 0.560030E+10 | 0.58 | 11546.64 | 05-SEP-06:03 | 1.94 |
October | 0.416551E+10 | 0.48 | 11546.64 | 02-OCT-04:02 | 1.94 |
November | 0.298115E+10 | 0.40 | 5596.62 | 14-NOV-16:30 | 1.24 |
December | 0.212394E+10 | 0.34 | 4223.96 | 27-DEC-16:40 | 1.05 |
Annual Sum or Average | 0.505166E+11 | 0.49 | |||
Minimum of Months | 0.173149E+10 | 0.32 | 4205.48 | 1.05 | |
Maximum of Months | 0.666182E+10 | 0.66 | 11546.64 | 1.96 |
Report: FanReportMonthly
For: PACU_VAV_MID FAN
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.183368E+10 | 0.34 | 3773.59 | 27-JAN-17:00 | 1.08 |
February | 0.136590E+10 | 0.32 | 2758.01 | 22-FEB-16:30 | 0.90 |
March | 0.194208E+10 | 0.36 | 4516.98 | 20-MAR-14:50 | 1.20 |
April | 0.392918E+10 | 0.51 | 7831.02 | 25-APR-15:20 | 1.68 |
May | 0.506740E+10 | 0.59 | 8179.28 | 08-MAY-16:00 | 1.74 |
June | 0.683066E+10 | 0.72 | 10019.19 | 19-JUN-04:02 | 1.98 |
July | 0.621530E+10 | 0.66 | 10019.19 | 10-JUL-04:02 | 1.96 |
August | 0.623286E+10 | 0.66 | 10019.19 | 14-AUG-04:02 | 1.96 |
September | 0.486511E+10 | 0.57 | 10019.19 | 02-SEP-05:03 | 1.95 |
October | 0.314211E+10 | 0.44 | 10019.19 | 02-OCT-04:02 | 1.96 |
November | 0.198271E+10 | 0.36 | 4688.68 | 02-NOV-15:50 | 1.22 |
December | 0.156287E+10 | 0.32 | 3116.55 | 26-DEC-16:50 | 0.97 |
Annual Sum or Average | 0.449699E+11 | 0.49 | |||
Minimum of Months | 0.136590E+10 | 0.32 | 2758.01 | 0.90 | |
Maximum of Months | 0.683066E+10 | 0.72 | 10019.19 | 1.98 |
Report: FanReportMonthly
For: PACU_VAV_TOP FAN
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.174809E+10 | 0.32 | 3316.48 | 31-JAN-16:30 | 0.90 |
February | 0.134049E+10 | 0.30 | 2375.28 | 22-FEB-16:30 | 0.75 |
March | 0.183513E+10 | 0.34 | 4251.85 | 16-MAR-15:40 | 1.03 |
April | 0.372689E+10 | 0.46 | 8317.50 | 24-APR-15:30 | 1.56 |
May | 0.484015E+10 | 0.52 | 8026.40 | 15-MAY-15:20 | 1.53 |
June | 0.685501E+10 | 0.66 | 11158.90 | 30-JUN-04:02 | 1.87 |
July | 0.603596E+10 | 0.59 | 11796.44 | 12-JUL-04:02 | 1.93 |
August | 0.606280E+10 | 0.59 | 11820.47 | 14-AUG-04:02 | 1.94 |
September | 0.457421E+10 | 0.50 | 8704.13 | 05-SEP-16:00 | 1.59 |
October | 0.284245E+10 | 0.39 | 11014.02 | 02-OCT-04:02 | 1.85 |
November | 0.179224E+10 | 0.33 | 4272.82 | 02-NOV-15:30 | 1.03 |
December | 0.152645E+10 | 0.31 | 2652.52 | 22-DEC-16:40 | 0.80 |
Annual Sum or Average | 0.431799E+11 | 0.44 | |||
Minimum of Months | 0.134049E+10 | 0.30 | 2375.28 | 0.75 | |
Maximum of Months | 0.685501E+10 | 0.66 | 11820.47 | 1.94 |
Report: PumpReportMonthly
For: SWHSYS1 PUMP
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportPUMP ELECTRICITY ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRICITY RATE {Maximum} [W] | PUMP ELECTRICITY RATE {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
January | 1312252.65 | 393675.80 | 0.73 | 01-JAN-06:10 | 0.22 | 0.22 | 56.67 | 0.05 |
February | 1186778.30 | 356033.49 | 0.73 | 01-FEB-06:02 | 0.22 | 0.22 | 56.65 | 0.05 |
March | 1343621.24 | 403086.37 | 0.73 | 01-MAR-06:03 | 0.22 | 0.22 | 55.88 | 0.05 |
April | 1267813.82 | 380344.15 | 0.73 | 01-APR-05:05 | 0.22 | 0.22 | 57.12 | 0.05 |
May | 1327936.95 | 398381.08 | 0.73 | 01-MAY-05:03 | 0.22 | 0.22 | 57.01 | 0.05 |
June | 1296568.36 | 388970.51 | 0.73 | 01-JUN-05:03 | 0.22 | 0.22 | 56.93 | 0.05 |
July | 1299182.41 | 389754.72 | 0.73 | 01-JUL-05:03 | 0.22 | 0.22 | 57.79 | 0.05 |
August | 1343621.24 | 403086.37 | 0.73 | 01-AUG-05:03 | 0.22 | 0.22 | 57.41 | 0.05 |
September | 1267813.82 | 380344.15 | 0.73 | 01-SEP-05:03 | 0.22 | 0.22 | 57.79 | 0.05 |
October | 1312252.65 | 393675.80 | 0.73 | 01-OCT-05:10 | 0.22 | 0.22 | 57.99 | 0.05 |
November | 1278270.02 | 383481.00 | 0.73 | 01-NOV-05:03 | 0.22 | 0.22 | 56.17 | 0.05 |
December | 1299182.41 | 389754.72 | 0.73 | 01-DEC-06:03 | 0.22 | 0.22 | 57.03 | 0.05 |
Annual Sum or Average | 15535293.87 | 4660588.16 | ||||||
Minimum of Months | 1186778.30 | 356033.49 | 0.73 | 0.22 | 0.22 | 55.88 | 0.05 | |
Maximum of Months | 1343621.24 | 403086.37 | 0.73 | 0.22 | 0.22 | 57.99 | 0.05 |
Report: CondLoopDemandReportMonthly
For: SWHSYS1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 56.83 | 56.83 | 1576.52 | 5410.91 | 12-JAN-12:10 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 57.57 | 57.57 | 1571.50 | 5436.48 | 02-FEB-12:09 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 56.27 | 56.27 | 1598.72 | 5262.45 | 01-MAR-12:15 |
April | 0.00 | 0.00 | 01-APR-00:10 | 57.53 | 57.53 | 1387.58 | 4881.43 | 03-APR-11:20 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 57.21 | 57.21 | 1318.09 | 4496.67 | 01-MAY-11:40 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 58.10 | 58.10 | 1248.63 | 4106.24 | 01-JUN-11:20 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 57.96 | 57.96 | 1103.07 | 3848.55 | 03-JUL-11:13 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 58.32 | 58.32 | 1224.55 | 3965.34 | 31-AUG-11:10 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 58.00 | 58.00 | 1217.72 | 4274.26 | 29-SEP-11:10 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 57.46 | 57.46 | 1324.07 | 4690.96 | 31-OCT-11:40 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 56.49 | 56.49 | 1460.88 | 5078.02 | 30-NOV-12:20 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 57.39 | 57.39 | 1492.33 | 5332.13 | 29-DEC-12:30 |
Annual Sum or Average | 0.00 | 1375.90 | ||||||
Minimum of Months | 0.00 | 0.00 | 56.27 | 56.27 | 1103.07 | 3848.55 | ||
Maximum of Months | 0.00 | 0.00 | 58.32 | 58.32 | 1598.72 | 5436.48 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PACU_VAV_BOT
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.743995E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.347291E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.739997E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.163675E+11 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.220979E+11 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.315869E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.305676E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.316912E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.264471E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.157089E+11 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.816810E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.499800E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.205946E+12 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.347291E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.316912E+11 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PACU_VAV_MID
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.549820E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.232628E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.557827E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.148059E+11 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.202263E+11 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.297447E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.271372E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.274640E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.218315E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.122132E+11 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.570745E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.363191E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.176165E+12 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.232628E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.297447E+11 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PACU_VAV_TOP
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.606539E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.311509E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.613617E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.159197E+11 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.219260E+11 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.330857E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.295931E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.296214E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.229919E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.125076E+11 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.587574E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.548865E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.192326E+12 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.311509E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.330857E+11 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PACU_VAV_BOT
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.249725E+10 | 0.171135E+11 | 0.640206E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.173149E+10 | 0.376141E+10 | 0.718328E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.244690E+10 | 0.162652E+11 | 0.813455E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.415220E+10 | 0.449031E+11 | 0.136984E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.534755E+10 | 0.595821E+11 | 7993040.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.666182E+10 | 0.794262E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.634553E+10 | 0.821151E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.646298E+10 | 0.860394E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.560030E+10 | 0.748346E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.416551E+10 | 0.424511E+11 | 0.247082E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.298115E+10 | 0.194380E+11 | 0.346477E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.212394E+10 | 0.814301E+10 | 0.991908E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.505166E+11 | 0.534073E+12 | 0.390243E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.173149E+10 | 0.376141E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.666182E+10 | 0.860394E+11 | 0.991908E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PACU_VAV_MID
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.183368E+10 | 0.140634E+11 | 0.133271E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.136590E+10 | 0.320158E+10 | 0.163263E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.194208E+10 | 0.138614E+11 | 0.171267E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.392918E+10 | 0.403849E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.506740E+10 | 0.539389E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.683066E+10 | 0.729318E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.621530E+10 | 0.710030E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.623286E+10 | 0.723462E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.486511E+10 | 0.606259E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.314211E+10 | 0.337297E+11 | 12344841.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.198271E+10 | 0.146064E+11 | 44124275.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.156287E+10 | 0.650936E+10 | 0.843915E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.449699E+11 | 0.457202E+12 | 0.136818E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.136590E+10 | 0.320158E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.683066E+10 | 0.729318E+11 | 0.843915E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PACU_VAV_TOP
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.174809E+10 | 0.137772E+11 | 0.874164E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.134049E+10 | 0.321634E+10 | 0.108412E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.183513E+10 | 0.145189E+11 | 0.732132E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.372689E+10 | 0.448235E+11 | 1665859.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.484015E+10 | 0.601765E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.685501E+10 | 0.827609E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.603596E+10 | 0.794066E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.606280E+10 | 0.796241E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.457421E+10 | 0.652116E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.284245E+10 | 0.351002E+11 | 0.144246E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.179224E+10 | 0.142315E+11 | 0.486600E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.152645E+10 | 0.623849E+10 | 0.307363E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.431799E+11 | 0.499086E+12 | 0.639656E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.134049E+10 | 0.321634E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.685501E+10 | 0.827609E+11 | 0.307363E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PACU_VAV_BOT
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.249725E+10 | 0.00 | 0.00 | 0.00 | 0.431229E+10 | 0.630417E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.173149E+10 | 0.00 | 0.00 | 0.00 | 0.102908E+10 | 0.712337E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.244690E+10 | 0.00 | 0.00 | 0.00 | 0.418705E+10 | 0.766025E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.415220E+10 | 0.00 | 0.00 | 0.00 | 0.120783E+11 | 0.136984E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.534755E+10 | 0.00 | 0.00 | 0.00 | 0.167424E+11 | 7993040.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.666182E+10 | 0.00 | 0.00 | 0.00 | 0.249251E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.634553E+10 | 0.00 | 0.00 | 0.00 | 0.242221E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.646298E+10 | 0.00 | 0.00 | 0.00 | 0.252282E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.560030E+10 | 0.00 | 0.00 | 0.00 | 0.208468E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.416551E+10 | 0.00 | 0.00 | 0.00 | 0.112964E+11 | 0.247036E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.298115E+10 | 0.00 | 0.00 | 0.00 | 0.484313E+10 | 0.343825E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.212394E+10 | 0.00 | 0.00 | 0.00 | 0.210702E+10 | 0.767045E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.505166E+11 | 0.00 | 0.00 | 0.00 | 0.151818E+12 | 0.361166E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.173149E+10 | 0.00 | 0.00 | 0.00 | 0.102908E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.666182E+10 | 0.00 | 0.00 | 0.00 | 0.252282E+11 | 0.767045E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PACU_VAV_MID
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.183368E+10 | 0.00 | 0.00 | 0.00 | 0.358573E+10 | 78791558.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.136590E+10 | 0.00 | 0.00 | 0.00 | 0.879801E+09 | 80587683.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.194208E+10 | 0.00 | 0.00 | 0.00 | 0.359531E+10 | 40881889.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.392918E+10 | 0.00 | 0.00 | 0.00 | 0.108767E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.506740E+10 | 0.00 | 0.00 | 0.00 | 0.151589E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.683066E+10 | 0.00 | 0.00 | 0.00 | 0.229140E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.621530E+10 | 0.00 | 0.00 | 0.00 | 0.209219E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.623286E+10 | 0.00 | 0.00 | 0.00 | 0.212311E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.486511E+10 | 0.00 | 0.00 | 0.00 | 0.169664E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.314211E+10 | 0.00 | 0.00 | 0.00 | 0.907106E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.198271E+10 | 0.00 | 0.00 | 0.00 | 0.371106E+10 | 13674713.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.156287E+10 | 0.00 | 0.00 | 0.00 | 0.170948E+10 | 0.359562E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.449699E+11 | 0.00 | 0.00 | 0.00 | 0.130622E+12 | 0.573498E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.136590E+10 | 0.00 | 0.00 | 0.00 | 0.879801E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.683066E+10 | 0.00 | 0.00 | 0.00 | 0.229140E+11 | 0.359562E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PACU_VAV_TOP
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.174809E+10 | 0.00 | 0.00 | 0.00 | 0.357843E+10 | 0.738872E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.134049E+10 | 0.00 | 0.00 | 0.00 | 0.891032E+09 | 0.883564E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.183513E+10 | 0.00 | 0.00 | 0.00 | 0.380348E+10 | 0.497567E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.372689E+10 | 0.00 | 0.00 | 0.00 | 0.121913E+11 | 1517376.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.484015E+10 | 0.00 | 0.00 | 0.00 | 0.170859E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.685501E+10 | 0.00 | 0.00 | 0.00 | 0.262307E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.603596E+10 | 0.00 | 0.00 | 0.00 | 0.235571E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.606280E+10 | 0.00 | 0.00 | 0.00 | 0.235586E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.457421E+10 | 0.00 | 0.00 | 0.00 | 0.184177E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.284245E+10 | 0.00 | 0.00 | 0.00 | 0.956647E+10 | 98687179.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.179224E+10 | 0.00 | 0.00 | 0.00 | 0.368237E+10 | 0.401123E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.152645E+10 | 0.00 | 0.00 | 0.00 | 0.166531E+10 | 0.229689E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.431799E+11 | 0.00 | 0.00 | 0.00 | 0.144228E+12 | 0.491822E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.134049E+10 | 0.00 | 0.00 | 0.00 | 0.891032E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.685501E+10 | 0.00 | 0.00 | 0.00 | 0.262307E+11 | 0.229689E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.116789E+10 | 1805315.00 | 0.00 | 34246495.23 | 11727857.13 | 0.00 | 0.119602E+11 | 0.00 | 0.86 |
February | 0.996369E+09 | 0.00 | 0.00 | 31066576.74 | 2509981.73 | 0.00 | 0.144881E+11 | 0.00 | 0.80 |
March | 0.812620E+09 | 15025836.62 | 0.00 | 37951173.87 | 399244.19 | 0.00 | 0.131246E+11 | 0.00 | 0.89 |
April | 0.515340E+09 | 0.599678E+09 | 0.00 | 24506745.30 | 91885340.55 | 0.00 | 0.504775E+10 | 0.00 | 0.66 |
May | 0.397997E+09 | 0.127402E+10 | 0.00 | 15891506.45 | 81384329.16 | 0.00 | 0.218784E+10 | 0.00 | 0.51 |
June | 0.160505E+09 | 0.340724E+10 | 0.00 | 4782926.67 | 0.129290E+09 | 0.00 | 0.657681E+09 | 0.00 | 0.36 |
July | 80686238.94 | 0.466379E+10 | 0.00 | 1429055.98 | 0.246724E+09 | 0.00 | 0.194918E+09 | 0.00 | 0.32 |
August | 57319138.27 | 0.476143E+10 | 0.00 | 2288961.51 | 0.171771E+09 | 0.00 | 0.219748E+09 | 0.00 | 0.40 |
September | 98394890.95 | 0.328073E+10 | 0.00 | 8320789.06 | 0.514319E+09 | 0.00 | 0.739441E+09 | 0.00 | 0.48 |
October | 0.562568E+09 | 0.719823E+09 | 0.00 | 30989441.77 | 67458723.76 | 0.00 | 0.881932E+10 | 0.00 | 0.80 |
November | 0.101878E+10 | 20574241.60 | 0.00 | 40683966.74 | 13630645.76 | 0.00 | 0.133931E+11 | 0.00 | 0.95 |
December | 0.113671E+10 | 913507.65 | 0.00 | 34371132.37 | 0.00 | 0.00 | 0.145899E+11 | 0.00 | 0.76 |
Annual Sum or Average | 0.700518E+10 | 0.187450E+11 | 0.00 | 0.266529E+09 | 0.133110E+10 | 0.00 | 0.854225E+11 | 0.00 | 0.65 |
Minimum of Months | 57319138.27 | 0.00 | 0.00 | 1429055.98 | 0.00 | 0.00 | 0.194918E+09 | 0.00 | 0.32 |
Maximum of Months | 0.116789E+10 | 0.476143E+10 | 0.00 | 40683966.74 | 0.514319E+09 | 0.00 | 0.145899E+11 | 0.00 | 0.95 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.372203E+10 | 0.00 | 0.00 | 10433210.94 | 5321554.78 | 0.00 | 0.418319E+10 | 0.00 | 0.51 |
February | 0.488194E+10 | 0.00 | 0.00 | 6813842.04 | 3024095.37 | 0.00 | 0.466661E+10 | 0.00 | 0.50 |
March | 0.346179E+10 | 2593865.46 | 0.00 | 13399909.82 | 529207.94 | 0.00 | 0.537224E+10 | 0.00 | 0.55 |
April | 0.721008E+09 | 0.382710E+09 | 0.00 | 16018082.02 | 0.126417E+09 | 0.00 | 0.306500E+10 | 0.00 | 0.46 |
May | 0.470029E+09 | 0.915287E+09 | 0.00 | 11937931.73 | 86368296.95 | 0.00 | 0.139884E+10 | 0.00 | 0.39 |
June | 0.247838E+09 | 0.283881E+10 | 0.00 | 3554805.64 | 0.175499E+09 | 0.00 | 0.466088E+09 | 0.00 | 0.32 |
July | 83902579.68 | 0.368196E+10 | 0.00 | 1041881.29 | 0.255564E+09 | 0.00 | 0.151073E+09 | 0.00 | 0.28 |
August | 82586273.53 | 0.370018E+10 | 0.00 | 1376677.20 | 0.193696E+09 | 0.00 | 0.127514E+09 | 0.00 | 0.34 |
September | 0.129435E+09 | 0.256644E+10 | 0.00 | 6062121.28 | 0.357699E+09 | 0.00 | 0.426712E+09 | 0.00 | 0.38 |
October | 0.114498E+10 | 0.557534E+09 | 0.00 | 15671587.36 | 73253400.99 | 0.00 | 0.447955E+10 | 0.00 | 0.51 |
November | 0.292348E+10 | 14371372.94 | 0.00 | 15011551.20 | 19882345.50 | 0.00 | 0.555740E+10 | 0.00 | 0.55 |
December | 0.595472E+10 | 23681.27 | 0.00 | 5208571.05 | 2723923.46 | 0.00 | 0.336619E+10 | 0.00 | 0.45 |
Annual Sum or Average | 0.238237E+11 | 0.146599E+11 | 0.00 | 0.106530E+09 | 0.129998E+10 | 0.00 | 0.332604E+11 | 0.00 | 0.44 |
Minimum of Months | 82586273.53 | 0.00 | 0.00 | 1041881.29 | 529207.94 | 0.00 | 0.127514E+09 | 0.00 | 0.28 |
Maximum of Months | 0.595472E+10 | 0.370018E+10 | 0.00 | 16018082.02 | 0.357699E+09 | 0.00 | 0.555740E+10 | 0.00 | 0.55 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.495021E+10 | 0.00 | 0.00 | 5287673.15 | 101079.37 | 33086001.23 | 0.228394E+10 | 0.00 | 0.52 |
February | 0.637546E+10 | 0.00 | 0.00 | 2754872.01 | 3750739.83 | 13772941.27 | 0.264492E+10 | 0.00 | 0.49 |
March | 0.492738E+10 | 993997.59 | 0.00 | 8245125.56 | 1556395.19 | 361310.08 | 0.330579E+10 | 0.00 | 0.56 |
April | 0.108809E+10 | 0.235701E+09 | 0.00 | 14919148.04 | 97595759.25 | 0.00 | 0.207595E+10 | 0.00 | 0.44 |
May | 0.527801E+09 | 0.640092E+09 | 0.00 | 13437728.74 | 64361507.28 | 0.00 | 0.816637E+09 | 0.00 | 0.35 |
June | 0.219060E+09 | 0.250261E+10 | 0.00 | 2974326.78 | 0.117230E+09 | 0.00 | 0.273960E+09 | 0.00 | 0.29 |
July | 63160258.13 | 0.338245E+10 | 0.00 | 920763.30 | 0.292762E+09 | 0.00 | 96095345.18 | 0.00 | 0.27 |
August | 69843410.35 | 0.345657E+10 | 0.00 | 1006026.51 | 0.198912E+09 | 0.00 | 53237435.76 | 0.00 | 0.32 |
September | 0.109166E+09 | 0.234433E+10 | 0.00 | 5451189.28 | 0.419875E+09 | 0.00 | 0.234670E+09 | 0.00 | 0.35 |
October | 0.191214E+10 | 0.473048E+09 | 0.00 | 11612244.00 | 84333024.51 | 0.00 | 0.279555E+10 | 0.00 | 0.47 |
November | 0.416702E+10 | 11366161.48 | 0.00 | 8986406.61 | 38429230.60 | 408805.77 | 0.347890E+10 | 0.00 | 0.54 |
December | 0.723881E+10 | 0.00 | 0.00 | 1686421.71 | 4743591.90 | 98573143.88 | 0.129598E+10 | 0.00 | 0.46 |
Annual Sum or Average | 0.316481E+11 | 0.130472E+11 | 0.00 | 77281925.68 | 0.132365E+10 | 0.146202E+09 | 0.193556E+11 | 0.00 | 0.42 |
Minimum of Months | 63160258.13 | 0.00 | 0.00 | 920763.30 | 101079.37 | 0.00 | 53237435.76 | 0.00 | 0.27 |
Maximum of Months | 0.723881E+10 | 0.345657E+10 | 0.00 | 14919148.04 | 0.419875E+09 | 98573143.88 | 0.347890E+10 | 0.00 | 0.56 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.120715E+10 | 0.00 | 0.00 | 585712.38 | 21303.28 | 91304789.54 | 0.215537E+09 | 0.00 | 0.51 |
February | 0.157914E+10 | 0.00 | 0.00 | 175604.52 | 790498.26 | 0.105539E+09 | 0.188566E+09 | 0.00 | 0.48 |
March | 0.120753E+10 | 263539.56 | 0.00 | 1604124.90 | 328022.67 | 72180720.46 | 0.455202E+09 | 0.00 | 0.56 |
April | 0.312794E+09 | 83076763.22 | 0.00 | 3457575.36 | 14290240.05 | 0.00 | 0.359125E+09 | 0.00 | 0.50 |
May | 0.141177E+09 | 0.238826E+09 | 0.00 | 3465187.55 | 9565789.60 | 0.00 | 0.152913E+09 | 0.00 | 0.46 |
June | 50550144.35 | 0.101586E+10 | 0.00 | 717646.61 | 13135511.45 | 0.00 | 55920234.88 | 0.00 | 0.48 |
July | 16580548.79 | 0.122034E+10 | 0.00 | 229567.01 | 45006620.60 | 0.00 | 18152713.03 | 0.00 | 0.42 |
August | 17116166.31 | 0.112083E+10 | 0.00 | 219499.51 | 36415052.44 | 0.00 | 7785445.83 | 0.00 | 0.46 |
September | 37140503.25 | 0.720958E+09 | 0.00 | 1397164.71 | 81617871.14 | 0.00 | 45078953.34 | 0.00 | 0.45 |
October | 0.612604E+09 | 0.135725E+09 | 0.00 | 2178992.97 | 15109267.95 | 10680790.87 | 0.338407E+09 | 0.00 | 0.49 |
November | 0.109506E+10 | 1398173.27 | 0.00 | 1243335.95 | 9112220.88 | 60724367.79 | 0.397505E+09 | 0.00 | 0.52 |
December | 0.146484E+10 | 0.00 | 0.00 | 100054.11 | 999749.73 | 0.296468E+09 | 57669869.20 | 0.00 | 0.45 |
Annual Sum or Average | 0.774169E+10 | 0.453728E+10 | 0.00 | 15374465.59 | 0.226392E+09 | 0.636897E+09 | 0.229186E+10 | 0.00 | 0.48 |
Minimum of Months | 16580548.79 | 0.00 | 0.00 | 100054.11 | 21303.28 | 0.00 | 7785445.83 | 0.00 | 0.42 |
Maximum of Months | 0.157914E+10 | 0.122034E+10 | 0.00 | 3465187.55 | 81617871.14 | 0.296468E+09 | 0.455202E+09 | 0.00 | 0.56 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.732581E+09 | 0.00 | 0.00 | 1499633.74 | 18730.90 | 40536816.91 | 0.634384E+09 | 0.00 | 0.76 |
February | 0.952626E+09 | 0.00 | 0.00 | 843814.55 | 695045.35 | 55700943.99 | 0.702719E+09 | 0.00 | 0.69 |
March | 0.730733E+09 | 615160.56 | 0.00 | 2686624.96 | 119376.64 | 34257723.58 | 0.991584E+09 | 0.00 | 0.90 |
April | 0.177230E+09 | 82069054.96 | 0.00 | 5230456.69 | 11033309.92 | 0.00 | 0.737833E+09 | 0.00 | 0.98 |
May | 97484745.01 | 0.192261E+09 | 0.00 | 4746795.68 | 7646057.07 | 0.00 | 0.300515E+09 | 0.00 | 0.83 |
June | 41510488.56 | 0.849310E+09 | 0.00 | 844299.19 | 10747777.47 | 0.00 | 59028768.97 | 0.00 | 0.70 |
July | 16417108.27 | 0.109142E+10 | 0.00 | 255133.42 | 42722538.73 | 0.00 | 18639103.44 | 0.00 | 0.61 |
August | 14693679.03 | 0.106113E+10 | 0.00 | 196335.78 | 32466201.27 | 0.00 | 8861516.04 | 0.00 | 0.67 |
September | 28683554.41 | 0.689909E+09 | 0.00 | 1302814.63 | 61960867.37 | 0.00 | 43510295.92 | 0.00 | 0.67 |
October | 0.355411E+09 | 0.132488E+09 | 0.00 | 3107166.70 | 10282938.18 | 7381103.17 | 0.701733E+09 | 0.00 | 0.84 |
November | 0.738016E+09 | 586847.00 | 0.00 | 2047640.20 | 8628528.89 | 19319969.01 | 0.716816E+09 | 0.00 | 0.80 |
December | 0.125765E+10 | 0.00 | 0.00 | 374027.60 | 879029.65 | 0.133641E+09 | 0.208229E+09 | 0.00 | 0.63 |
Annual Sum or Average | 0.514303E+10 | 0.409978E+10 | 0.00 | 23134743.15 | 0.187200E+09 | 0.290837E+09 | 0.512385E+10 | 0.00 | 0.76 |
Minimum of Months | 14693679.03 | 0.00 | 0.00 | 196335.78 | 18730.90 | 0.00 | 8861516.04 | 0.00 | 0.61 |
Maximum of Months | 0.125765E+10 | 0.109142E+10 | 0.00 | 5230456.69 | 61960867.37 | 0.133641E+09 | 0.991584E+09 | 0.00 | 0.98 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.616374E+09 | 78858.23 | 0.00 | 9646229.34 | 2512.60 | 40158213.48 | 0.293829E+10 | 0.00 | 1.39 |
February | 0.893914E+09 | 0.00 | 0.00 | 5335522.29 | 861371.47 | 65316328.56 | 0.287962E+10 | 0.00 | 0.95 |
March | 0.822695E+09 | 722009.14 | 0.00 | 5781368.40 | 216413.94 | 56704524.84 | 0.189308E+10 | 0.00 | 0.95 |
April | 0.324504E+09 | 0.133622E+09 | 0.00 | 5428732.08 | 13329083.06 | 0.00 | 0.574065E+09 | 0.00 | 0.69 |
May | 0.184169E+09 | 0.263317E+09 | 0.00 | 3624689.26 | 9283592.58 | 0.00 | 0.128839E+09 | 0.00 | 0.50 |
June | 64380039.64 | 0.987237E+09 | 0.00 | 544385.89 | 15142756.78 | 0.00 | 39904671.52 | 0.00 | 0.46 |
July | 20474072.76 | 0.122200E+10 | 0.00 | 199477.09 | 54704205.49 | 0.00 | 13545979.13 | 0.00 | 0.43 |
August | 20106474.77 | 0.129086E+10 | 0.00 | 218530.26 | 38062910.40 | 0.00 | 6571692.82 | 0.00 | 0.52 |
September | 39941107.52 | 0.991142E+09 | 0.00 | 2044593.45 | 76575142.44 | 0.00 | 62230480.59 | 0.00 | 0.59 |
October | 0.374971E+09 | 0.232665E+09 | 0.00 | 7778986.99 | 10710342.82 | 3446022.82 | 0.157107E+10 | 0.00 | 0.99 |
November | 0.620201E+09 | 2680089.57 | 0.00 | 8872297.58 | 8993656.12 | 19208659.40 | 0.289555E+10 | 0.00 | 1.26 |
December | 0.803916E+09 | 293076.73 | 0.00 | 7157544.80 | 898666.61 | 0.139297E+09 | 0.285739E+10 | 0.00 | 1.05 |
Annual Sum or Average | 0.478565E+10 | 0.512462E+10 | 0.00 | 56632357.42 | 0.228781E+09 | 0.324131E+09 | 0.158602E+11 | 0.00 | 0.81 |
Minimum of Months | 20106474.77 | 0.00 | 0.00 | 199477.09 | 2512.60 | 0.00 | 6571692.82 | 0.00 | 0.43 |
Maximum of Months | 0.893914E+09 | 0.129086E+10 | 0.00 | 9646229.34 | 76575142.44 | 0.139297E+09 | 0.293829E+10 | 0.00 | 1.39 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.107723E+10 | 31892.64 | 0.00 | 1909039.29 | 4116.55 | 84362960.36 | 0.548317E+09 | 0.00 | 0.97 |
February | 0.133837E+10 | 0.00 | 0.00 | 1113674.41 | 788769.07 | 97305697.50 | 0.669346E+09 | 0.00 | 0.86 |
March | 0.113687E+10 | 235590.25 | 0.00 | 2320052.03 | 318919.16 | 69322258.82 | 0.689090E+09 | 0.00 | 1.01 |
April | 0.334460E+09 | 0.109902E+09 | 0.00 | 3834826.01 | 5658131.84 | 177442.81 | 0.373795E+09 | 0.00 | 0.86 |
May | 0.181808E+09 | 0.268937E+09 | 0.00 | 2530874.00 | 4163809.27 | 0.00 | 80648089.28 | 0.00 | 0.68 |
June | 59354227.86 | 0.922616E+09 | 0.00 | 343348.82 | 11243943.67 | 0.00 | 32341350.24 | 0.00 | 0.65 |
July | 21320556.94 | 0.954118E+09 | 0.00 | 126894.21 | 51462633.73 | 0.00 | 8977809.79 | 0.00 | 0.53 |
August | 20054360.47 | 0.899731E+09 | 0.00 | 160056.43 | 45389539.11 | 0.00 | 3901395.63 | 0.00 | 0.60 |
September | 39050940.70 | 0.588218E+09 | 0.00 | 1193088.44 | 87888149.02 | 0.00 | 36543856.88 | 0.00 | 0.60 |
October | 0.569196E+09 | 0.109544E+09 | 0.00 | 2901191.34 | 19353245.55 | 13341962.41 | 0.485916E+09 | 0.00 | 0.82 |
November | 0.102258E+10 | 1304908.46 | 0.00 | 2235735.67 | 9282485.64 | 56638606.61 | 0.689596E+09 | 0.00 | 0.97 |
December | 0.123827E+10 | 16677.19 | 0.00 | 879506.41 | 980885.62 | 0.254964E+09 | 0.441289E+09 | 0.00 | 0.78 |
Annual Sum or Average | 0.703857E+10 | 0.385466E+10 | 0.00 | 19548287.06 | 0.236535E+09 | 0.576112E+09 | 0.405976E+10 | 0.00 | 0.78 |
Minimum of Months | 20054360.47 | 0.00 | 0.00 | 126894.21 | 4116.55 | 0.00 | 3901395.63 | 0.00 | 0.53 |
Maximum of Months | 0.133837E+10 | 0.954118E+09 | 0.00 | 3834826.01 | 87888149.02 | 0.254964E+09 | 0.689596E+09 | 0.00 | 1.01 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.152306E+10 | 107955.38 | 0.00 | 341021.77 | 2645812.16 | 14406117.57 | 0.154311E+09 | 0.00 | 0.51 |
February | 0.197944E+10 | 0.00 | 0.00 | 13397.07 | 529430.88 | 12570665.34 | 35490407.80 | 0.00 | 0.49 |
March | 0.157037E+10 | 1389443.01 | 0.00 | 568604.20 | 533352.30 | 15497723.73 | 0.166800E+09 | 0.00 | 0.51 |
April | 0.430304E+09 | 0.103595E+09 | 0.00 | 1775776.48 | 23481983.17 | 0.00 | 0.261408E+09 | 0.00 | 0.42 |
May | 0.230614E+09 | 0.269974E+09 | 0.00 | 1412200.95 | 13351144.96 | 0.00 | 0.136770E+09 | 0.00 | 0.38 |
June | 94380345.02 | 0.931870E+09 | 0.00 | 484120.39 | 24867680.16 | 0.00 | 53758076.50 | 0.00 | 0.40 |
July | 29789329.25 | 0.122514E+10 | 0.00 | 194878.48 | 52179133.49 | 0.00 | 22500177.29 | 0.00 | 0.38 |
August | 29524015.40 | 0.117443E+10 | 0.00 | 229976.87 | 41644688.89 | 0.00 | 18457291.65 | 0.00 | 0.43 |
September | 51244204.89 | 0.810961E+09 | 0.00 | 1289503.47 | 0.107755E+09 | 0.00 | 89252977.53 | 0.00 | 0.48 |
October | 0.535232E+09 | 0.155260E+09 | 0.00 | 2494845.45 | 18467455.43 | 0.00 | 0.619681E+09 | 0.00 | 0.54 |
November | 0.114174E+10 | 1270373.48 | 0.00 | 2111583.56 | 4687561.61 | 0.00 | 0.671990E+09 | 0.00 | 0.55 |
December | 0.196608E+10 | 0.00 | 0.00 | 139260.51 | 119205.43 | 28726834.03 | 0.111626E+09 | 0.00 | 0.47 |
Annual Sum or Average | 0.958177E+10 | 0.467399E+10 | 0.00 | 11055169.20 | 0.290262E+09 | 71201340.67 | 0.234205E+10 | 0.00 | 0.46 |
Minimum of Months | 29524015.40 | 0.00 | 0.00 | 13397.07 | 119205.43 | 0.00 | 18457291.65 | 0.00 | 0.38 |
Maximum of Months | 0.197944E+10 | 0.122514E+10 | 0.00 | 2494845.45 | 0.107755E+09 | 28726834.03 | 0.671990E+09 | 0.00 | 0.55 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.748406E+09 | 156667.39 | 0.00 | 1931573.34 | 2012831.87 | 2267817.47 | 0.747606E+09 | 0.00 | 0.72 |
February | 0.968202E+09 | 0.00 | 0.00 | 944354.47 | 411201.73 | 2216893.37 | 0.700160E+09 | 0.00 | 0.63 |
March | 0.774968E+09 | 1711150.21 | 0.00 | 2080822.25 | 65406.81 | 1034840.70 | 0.786550E+09 | 0.00 | 0.74 |
April | 0.198515E+09 | 0.119936E+09 | 0.00 | 3803494.68 | 11936595.26 | 0.00 | 0.698029E+09 | 0.00 | 0.86 |
May | 0.142455E+09 | 0.255092E+09 | 0.00 | 2750039.37 | 8065771.41 | 0.00 | 0.309589E+09 | 0.00 | 0.73 |
June | 56950808.06 | 0.826316E+09 | 0.00 | 669830.48 | 17084598.07 | 0.00 | 77373689.54 | 0.00 | 0.61 |
July | 17618412.30 | 0.110602E+10 | 0.00 | 253633.25 | 36242399.99 | 0.00 | 31211529.67 | 0.00 | 0.55 |
August | 17737138.84 | 0.109937E+10 | 0.00 | 297054.93 | 26195669.30 | 0.00 | 25863264.02 | 0.00 | 0.63 |
September | 38274746.09 | 0.758461E+09 | 0.00 | 1269136.19 | 63331714.39 | 0.00 | 91809054.36 | 0.00 | 0.69 |
October | 0.250128E+09 | 0.146422E+09 | 0.00 | 3852105.82 | 10261830.89 | 0.00 | 0.108103E+10 | 0.00 | 0.94 |
November | 0.576042E+09 | 1075137.18 | 0.00 | 3532551.97 | 3640765.01 | 0.00 | 0.119376E+10 | 0.00 | 0.87 |
December | 0.106570E+10 | 28372.34 | 0.00 | 1126180.38 | 64212.89 | 3582065.54 | 0.659617E+09 | 0.00 | 0.62 |
Annual Sum or Average | 0.485500E+10 | 0.431459E+10 | 0.00 | 22510777.13 | 0.179313E+09 | 9101617.08 | 0.640259E+10 | 0.00 | 0.72 |
Minimum of Months | 17618412.30 | 0.00 | 0.00 | 253633.25 | 64212.89 | 0.00 | 25863264.02 | 0.00 | 0.55 |
Maximum of Months | 0.106570E+10 | 0.110602E+10 | 0.00 | 3852105.82 | 63331714.39 | 3582065.54 | 0.119376E+10 | 0.00 | 0.94 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.578926E+09 | 1848041.15 | 0.00 | 8263547.65 | 2120827.34 | 0.268492E+09 | 0.228230E+10 | 0.00 | 1.17 |
February | 0.129292E+10 | 0.00 | 0.00 | 1814299.68 | 528851.56 | 0.313253E+09 | 0.110214E+10 | 0.00 | 0.66 |
March | 0.114319E+10 | 3964760.50 | 0.00 | 2830219.21 | 84120.50 | 0.336285E+09 | 0.661443E+09 | 0.00 | 0.68 |
April | 0.406707E+09 | 0.235292E+09 | 0.00 | 3161126.46 | 12672102.02 | 64476638.98 | 0.316362E+09 | 0.00 | 0.61 |
May | 0.282676E+09 | 0.418688E+09 | 0.00 | 1559446.52 | 11007385.24 | 5072966.73 | 74407790.58 | 0.00 | 0.48 |
June | 0.113326E+09 | 0.123711E+10 | 0.00 | 327846.67 | 24702716.69 | 0.00 | 25358338.47 | 0.00 | 0.48 |
July | 32181949.89 | 0.157718E+10 | 0.00 | 171752.98 | 55291603.55 | 0.00 | 16581822.44 | 0.00 | 0.46 |
August | 31624465.19 | 0.171451E+10 | 0.00 | 204944.76 | 39901089.76 | 0.00 | 14325851.23 | 0.00 | 0.57 |
September | 60139570.76 | 0.126995E+10 | 0.00 | 1886422.91 | 83102088.90 | 0.00 | 92942295.86 | 0.00 | 0.65 |
October | 0.371988E+09 | 0.296915E+09 | 0.00 | 6968144.29 | 8786813.18 | 0.118682E+09 | 0.139524E+10 | 0.00 | 1.00 |
November | 0.520146E+09 | 3056076.05 | 0.00 | 9140046.10 | 4150547.47 | 0.162975E+09 | 0.262687E+10 | 0.00 | 1.15 |
December | 0.981388E+09 | 78508.00 | 0.00 | 5933596.31 | 82584.98 | 0.349506E+09 | 0.217951E+10 | 0.00 | 0.94 |
Annual Sum or Average | 0.581521E+10 | 0.675859E+10 | 0.00 | 42261393.54 | 0.242431E+09 | 0.161874E+10 | 0.107875E+11 | 0.00 | 0.74 |
Minimum of Months | 31624465.19 | 0.00 | 0.00 | 171752.98 | 82584.98 | 0.00 | 14325851.23 | 0.00 | 0.46 |
Maximum of Months | 0.129292E+10 | 0.171451E+10 | 0.00 | 9140046.10 | 83102088.90 | 0.349506E+09 | 0.262687E+10 | 0.00 | 1.17 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.106789E+10 | 386187.18 | 0.00 | 1723048.61 | 1986855.51 | 4379089.25 | 0.454115E+09 | 0.00 | 0.79 |
February | 0.135059E+10 | 0.00 | 0.00 | 800110.38 | 433086.15 | 8796370.67 | 0.443585E+09 | 0.00 | 0.70 |
March | 0.112944E+10 | 2062011.72 | 0.00 | 1420532.43 | 0.00 | 1002951.55 | 0.392397E+09 | 0.00 | 0.75 |
April | 0.307534E+09 | 0.154287E+09 | 0.00 | 2300162.97 | 5996631.12 | 0.00 | 0.329376E+09 | 0.00 | 0.71 |
May | 0.179291E+09 | 0.332272E+09 | 0.00 | 1156150.84 | 2695936.31 | 0.00 | 0.120006E+09 | 0.00 | 0.58 |
June | 65266809.41 | 0.915259E+09 | 0.00 | 397337.11 | 13931732.54 | 0.00 | 51272029.19 | 0.00 | 0.57 |
July | 19806341.07 | 0.100449E+10 | 0.00 | 181600.66 | 34979935.70 | 0.00 | 22331446.30 | 0.00 | 0.48 |
August | 16368935.55 | 0.101220E+10 | 0.00 | 212293.24 | 21834865.93 | 0.00 | 22909710.20 | 0.00 | 0.56 |
September | 38897828.04 | 0.697031E+09 | 0.00 | 1012967.08 | 77396736.51 | 0.00 | 70700011.44 | 0.00 | 0.61 |
October | 0.342471E+09 | 0.138564E+09 | 0.00 | 3041246.92 | 10316120.78 | 0.00 | 0.731210E+09 | 0.00 | 0.81 |
November | 0.695435E+09 | 1692142.46 | 0.00 | 3321099.99 | 3826702.01 | 0.00 | 0.103150E+10 | 0.00 | 0.88 |
December | 0.133912E+10 | 0.00 | 0.00 | 1130310.48 | 97512.67 | 9610187.98 | 0.524019E+09 | 0.00 | 0.69 |
Annual Sum or Average | 0.655211E+10 | 0.425825E+10 | 0.00 | 16696860.69 | 0.173496E+09 | 23788599.46 | 0.419342E+10 | 0.00 | 0.68 |
Minimum of Months | 16368935.55 | 0.00 | 0.00 | 181600.66 | 0.00 | 0.00 | 22331446.30 | 0.00 | 0.48 |
Maximum of Months | 0.135059E+10 | 0.101220E+10 | 0.00 | 3321099.99 | 77396736.51 | 9610187.98 | 0.103150E+10 | 0.00 | 0.88 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.129960E+10 | 0.00 | 0.00 | 782804.86 | 1121608.86 | 14374096.24 | 0.267023E+09 | 0.00 | 0.48 |
February | 0.164445E+10 | 0.00 | 0.00 | 281186.27 | 637379.92 | 12383872.95 | 0.271257E+09 | 0.00 | 0.47 |
March | 0.120206E+10 | 665613.34 | 0.00 | 1868908.12 | 111539.64 | 8106639.76 | 0.567708E+09 | 0.00 | 0.54 |
April | 0.314959E+09 | 0.134942E+09 | 0.00 | 2903607.02 | 18049200.89 | 0.00 | 0.411118E+09 | 0.00 | 0.50 |
May | 0.147706E+09 | 0.346742E+09 | 0.00 | 2611982.86 | 12194216.99 | 0.00 | 0.234103E+09 | 0.00 | 0.50 |
June | 61877648.01 | 0.119564E+10 | 0.00 | 791628.45 | 23099530.60 | 0.00 | 94328636.35 | 0.00 | 0.51 |
July | 26470956.15 | 0.134657E+10 | 0.00 | 213724.46 | 42532021.04 | 0.00 | 24846035.29 | 0.00 | 0.45 |
August | 23249443.97 | 0.124052E+10 | 0.00 | 225708.24 | 33598681.01 | 0.00 | 17847111.89 | 0.00 | 0.48 |
September | 40614498.17 | 0.815238E+09 | 0.00 | 1313515.62 | 67256694.12 | 0.00 | 72904298.68 | 0.00 | 0.48 |
October | 0.587048E+09 | 0.160317E+09 | 0.00 | 2103914.26 | 12053823.70 | 0.00 | 0.446590E+09 | 0.00 | 0.50 |
November | 0.112801E+10 | 1346760.07 | 0.00 | 1707553.85 | 5800319.01 | 3435944.19 | 0.510657E+09 | 0.00 | 0.51 |
December | 0.177501E+10 | 0.00 | 0.00 | 143320.27 | 579104.78 | 91871791.46 | 61770352.23 | 0.00 | 0.44 |
Annual Sum or Average | 0.825105E+10 | 0.524198E+10 | 0.00 | 14947854.28 | 0.217034E+09 | 0.130172E+09 | 0.298015E+10 | 0.00 | 0.49 |
Minimum of Months | 23249443.97 | 0.00 | 0.00 | 143320.27 | 111539.64 | 0.00 | 17847111.89 | 0.00 | 0.44 |
Maximum of Months | 0.177501E+10 | 0.134657E+10 | 0.00 | 2903607.02 | 67256694.12 | 91871791.46 | 0.567708E+09 | 0.00 | 0.54 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.768035E+09 | 0.00 | 0.00 | 1920507.69 | 976694.26 | 9673510.17 | 0.787405E+09 | 0.00 | 0.74 |
February | 0.100225E+10 | 0.00 | 0.00 | 1161898.28 | 555028.88 | 6579028.73 | 0.825376E+09 | 0.00 | 0.70 |
March | 0.743321E+09 | 515010.27 | 0.00 | 2990494.71 | 97128.45 | 4889830.52 | 0.111696E+10 | 0.00 | 0.88 |
April | 0.181454E+09 | 0.126473E+09 | 0.00 | 4738864.97 | 13084997.19 | 0.00 | 0.846331E+09 | 0.00 | 0.99 |
May | 0.116354E+09 | 0.277556E+09 | 0.00 | 3772691.41 | 9666552.45 | 0.00 | 0.396288E+09 | 0.00 | 0.87 |
June | 53806578.83 | 0.975012E+09 | 0.00 | 845475.28 | 16860373.28 | 0.00 | 91183920.50 | 0.00 | 0.74 |
July | 21421069.20 | 0.117348E+10 | 0.00 | 235976.96 | 38791988.05 | 0.00 | 28567097.36 | 0.00 | 0.63 |
August | 21092021.82 | 0.112313E+10 | 0.00 | 234607.24 | 29035650.70 | 0.00 | 18452896.63 | 0.00 | 0.69 |
September | 36376768.43 | 0.738561E+09 | 0.00 | 1251678.19 | 50803238.07 | 0.00 | 71548218.76 | 0.00 | 0.70 |
October | 0.363953E+09 | 0.141890E+09 | 0.00 | 3088870.96 | 10733488.69 | 0.00 | 0.850305E+09 | 0.00 | 0.86 |
November | 0.740024E+09 | 1040311.50 | 0.00 | 2553987.48 | 5096976.06 | 562639.89 | 0.894441E+09 | 0.00 | 0.79 |
December | 0.130371E+10 | 0.00 | 0.00 | 658015.21 | 504283.03 | 46227835.64 | 0.375944E+09 | 0.00 | 0.63 |
Annual Sum or Average | 0.535179E+10 | 0.455766E+10 | 0.00 | 23453068.39 | 0.176206E+09 | 67932844.94 | 0.630280E+10 | 0.00 | 0.77 |
Minimum of Months | 21092021.82 | 0.00 | 0.00 | 234607.24 | 97128.45 | 0.00 | 18452896.63 | 0.00 | 0.63 |
Maximum of Months | 0.130371E+10 | 0.117348E+10 | 0.00 | 4738864.97 | 50803238.07 | 46227835.64 | 0.111696E+10 | 0.00 | 0.99 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.569466E+09 | 3542167.15 | 0.00 | 10116873.59 | 231145.89 | 4535988.29 | 0.292575E+10 | 0.00 | 1.26 |
February | 0.854805E+09 | 0.00 | 0.00 | 5924565.32 | 637253.39 | 3946815.47 | 0.298574E+10 | 0.00 | 0.95 |
March | 0.758345E+09 | 1115526.75 | 0.00 | 6299331.36 | 111517.50 | 2792343.20 | 0.194032E+10 | 0.00 | 0.89 |
April | 0.298626E+09 | 0.225810E+09 | 0.00 | 4351049.88 | 13514793.55 | 0.00 | 0.583732E+09 | 0.00 | 0.68 |
May | 0.163689E+09 | 0.390904E+09 | 0.00 | 2511786.45 | 11442663.18 | 0.00 | 0.199782E+09 | 0.00 | 0.52 |
June | 74073207.24 | 0.117314E+10 | 0.00 | 606963.81 | 21249146.08 | 0.00 | 67677269.07 | 0.00 | 0.48 |
July | 26465701.23 | 0.136459E+10 | 0.00 | 184637.71 | 45294529.06 | 0.00 | 20545452.22 | 0.00 | 0.45 |
August | 22888814.78 | 0.145889E+10 | 0.00 | 225504.20 | 28940226.40 | 0.00 | 17570360.34 | 0.00 | 0.54 |
September | 39457815.10 | 0.114268E+10 | 0.00 | 1829984.70 | 56790110.55 | 0.00 | 88221847.84 | 0.00 | 0.61 |
October | 0.329173E+09 | 0.279385E+09 | 0.00 | 6982085.03 | 9002400.02 | 0.00 | 0.162670E+10 | 0.00 | 0.98 |
November | 0.535992E+09 | 2066676.75 | 0.00 | 9986630.54 | 5740213.90 | 120333.34 | 0.298367E+10 | 0.00 | 1.19 |
December | 0.834160E+09 | 236601.29 | 0.00 | 8414118.14 | 427044.69 | 26493694.51 | 0.316628E+10 | 0.00 | 1.07 |
Annual Sum or Average | 0.450714E+10 | 0.604236E+10 | 0.00 | 57433530.72 | 0.193381E+09 | 37889174.81 | 0.166060E+11 | 0.00 | 0.80 |
Minimum of Months | 22888814.78 | 0.00 | 0.00 | 184637.71 | 111517.50 | 0.00 | 17570360.34 | 0.00 | 0.45 |
Maximum of Months | 0.854805E+09 | 0.145889E+10 | 0.00 | 10116873.59 | 56790110.55 | 26493694.51 | 0.316628E+10 | 0.00 | 1.26 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.113191E+10 | 1083292.34 | 0.00 | 1994014.61 | 360842.90 | 11578108.68 | 0.501145E+09 | 0.00 | 0.84 |
February | 0.137970E+10 | 0.00 | 0.00 | 1226064.77 | 591809.24 | 13136840.55 | 0.643410E+09 | 0.00 | 0.80 |
March | 0.110052E+10 | 758453.99 | 0.00 | 2436817.03 | 0.00 | 6518376.24 | 0.678287E+09 | 0.00 | 0.90 |
April | 0.322133E+09 | 0.180222E+09 | 0.00 | 2858985.29 | 5269809.58 | 0.00 | 0.368864E+09 | 0.00 | 0.82 |
May | 0.176370E+09 | 0.400876E+09 | 0.00 | 1672929.72 | 3289609.88 | 0.00 | 0.125977E+09 | 0.00 | 0.70 |
June | 70445590.81 | 0.113590E+10 | 0.00 | 418843.67 | 15460510.12 | 0.00 | 51621011.49 | 0.00 | 0.70 |
July | 24623363.58 | 0.108418E+10 | 0.00 | 121927.61 | 36277975.37 | 0.00 | 16306355.49 | 0.00 | 0.56 |
August | 23538303.69 | 0.103948E+10 | 0.00 | 131723.24 | 24739488.08 | 0.00 | 11285382.20 | 0.00 | 0.63 |
September | 44776128.08 | 0.685287E+09 | 0.00 | 971555.47 | 60718835.89 | 0.00 | 51170914.31 | 0.00 | 0.62 |
October | 0.531973E+09 | 0.139107E+09 | 0.00 | 2499576.70 | 9893545.45 | 0.00 | 0.521821E+09 | 0.00 | 0.78 |
November | 0.976533E+09 | 1610881.68 | 0.00 | 2551164.14 | 5353305.69 | 2298044.61 | 0.741785E+09 | 0.00 | 0.86 |
December | 0.138675E+10 | 0.00 | 0.00 | 1042156.59 | 537700.59 | 88868889.26 | 0.463662E+09 | 0.00 | 0.73 |
Annual Sum or Average | 0.716926E+10 | 0.466851E+10 | 0.00 | 17925758.83 | 0.162493E+09 | 0.122400E+09 | 0.417533E+10 | 0.00 | 0.75 |
Minimum of Months | 23538303.69 | 0.00 | 0.00 | 121927.61 | 0.00 | 0.00 | 11285382.20 | 0.00 | 0.56 |
Maximum of Months | 0.138675E+10 | 0.113590E+10 | 0.00 | 2858985.29 | 60718835.89 | 88868889.26 | 0.741785E+09 | 0.00 | 0.90 |
Report: HeatEmissionsReportMonthly
For: Environment
Timestamp: 2023-10-16 08:35:20
Custom Monthly ReportSITE TOTAL SURFACE HEAT EMISSION TO AIR [J] | SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] | SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] | AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] | HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J] | |
January | 0.198798E+12 | 0.353826E+10 | 0.00 | 0.177147E+12 | 0.564804E+11 |
February | 0.205017E+12 | 0.389266E+10 | 0.00 | 0.181751E+12 | 0.130516E+11 |
March | 0.259562E+12 | 0.362058E+10 | 0.00 | 0.184073E+12 | 0.563345E+11 |
April | 0.306257E+12 | 0.358065E+09 | 0.00 | 0.980270E+11 | 0.165258E+12 |
May | 0.297258E+12 | -920026609.9 | 0.00 | 0.627460E+11 | 0.222685E+12 |
June | 0.302929E+12 | -0.276957E+10 | 0.00 | -0.210841E+10 | 0.309189E+12 |
July | 0.280780E+12 | -0.357660E+10 | 0.00 | -0.412963E+11 | 0.301226E+12 |
August | 0.253183E+12 | -0.343492E+10 | 0.00 | -0.345016E+11 | 0.308028E+12 |
September | 0.219659E+12 | -0.214681E+10 | 0.00 | -0.404485E+11 | 0.256903E+12 |
October | 0.218365E+12 | 0.129475E+10 | 0.00 | 0.129782E+12 | 0.141229E+12 |
November | 0.200020E+12 | 0.323858E+10 | 0.00 | 0.171733E+12 | 0.605420E+11 |
December | 0.165396E+12 | 0.452134E+10 | 0.00 | 0.192361E+12 | 0.267441E+11 |
Annual Sum or Average | 0.290722E+13 | 0.761631E+10 | 0.00 | 0.107927E+13 | 0.191767E+13 |
Minimum of Months | 0.165396E+12 | -0.357660E+10 | 0.00 | -0.412963E+11 | 0.130516E+11 |