Table of Contents

Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 08:29

Tabular Output Report in Format: HTML

Building: OfficeSmall

Environment: RUNPERIOD 1 ** Denver-Aurora-Buckley AFB CO USA TMY3 WMO#=724695

Simulation Timestamp: 2023-10-16 08:29:19


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 209.55 409.95 409.95
Net Site Energy 209.55 409.95 409.95
Total Source Energy 640.32 1252.69 1252.69
Net Source Energy 640.32 1252.69 1252.69


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 1.200
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil No 1 1.050
Fuel Oil No 2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 511.16
Net Conditioned Building Area 511.16
Unconditioned Building Area 0.00


End Uses

Electricity [GJ] Natural Gas [GJ] Gasoline [GJ] Diesel [GJ] Coal [GJ] Fuel Oil No 1 [GJ] Fuel Oil No 2 [GJ] Propane [GJ] Other Fuel 1 [GJ] Other Fuel 2 [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 16.10 11.19 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 14.64 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 42.12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 20.69 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 52.80 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 27.03 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 24.98 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 58.31
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                           
Total End Uses 198.36 11.19 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 58.31
Note: Electricity appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Gasoline [GJ] Diesel [GJ] Coal [GJ] Fuel Oil No 1 [GJ] Fuel Oil No 2 [GJ] Propane [GJ] Other Fuel 1 [GJ] Other Fuel 2 [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating General 16.10 11.19 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling General 14.64 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting LightsWired 42.12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 20.69 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 52.80 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans General 27.03 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  Water Heater 24.98 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 29.16
  WaterUse 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 29.16
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


End Uses By Space Type

Space Type Electricity [GJ] Natural Gas [GJ] Gasoline [GJ] Diesel [GJ] Coal [GJ] Fuel Oil No 1 [GJ] Fuel Oil No 2 [GJ] Propane [GJ] Other Fuel 1 [GJ] Other Fuel 2 [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating Unassigned 16.10 11.19 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling Unassigned 14.64 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting GENERAL 42.12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting Unassigned 20.69 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment GENERAL 52.80 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans Unassigned 27.03 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Unassigned 24.98 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 58.31
Refrigeration Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Gasoline Intensity [MJ/m2] Diesel Intensity [MJ/m2] Coal Intensity [MJ/m2] Fuel Oil No 1 Intensity [MJ/m2] Fuel Oil No 2 Intensity [MJ/m2] Propane Intensity [MJ/m2] Other Fuel 1 Intensity [MJ/m2] Other Fuel 2 Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 122.88 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
HVAC 161.88 21.90 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.11
Other 103.29 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total 388.05 21.90 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.11


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Gasoline Intensity [MJ/m2] Diesel Intensity [MJ/m2] Coal Intensity [MJ/m2] Fuel Oil No 1 Intensity [MJ/m2] Fuel Oil No 2 Intensity [MJ/m2] Propane Intensity [MJ/m2] Other Fuel 1 Intensity [MJ/m2] Other Fuel 2 Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 122.88 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
HVAC 161.88 21.90 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.11
Other 103.29 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total 388.05 21.90 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.11


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.000 0.00
High Temperature Geothermal* 0.000 0.00
Photovoltaic Power 0.000 0.00
Wind Power 0.000 0.00
Power Conversion 0.000 0.00
Net Decrease in On-Site Storage 0.000 0.00
Total On-Site Electric Sources 0.000 0.00
     
Electricity Coming From Utility 198.355 100.00
Surplus Electricity Going To Utility 0.000 0.00
Net Electricity From Utility 198.355 100.00
     
Total On-Site and Utility Electric Sources 198.355 100.00
Total Electricity End Uses 198.355 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 58.31 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 58.31 100.00
Total Water End Uses 58.31 100.00


Setpoint Not Met Criteria

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.56
Tolerance for Zone Cooling Setpoint Not Met Time 0.56


Comfort and Setpoint Not Met Summary

Facility [Hours]
Time Setpoint Not Met During Occupied Heating 20.83
Time Setpoint Not Met During Occupied Cooling 8.50
Time Not Comfortable Based on Simple ASHRAE 55-2004 2123.17


Note 1: An asterisk (*) indicates that the feature is not yet implemented.

Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Adaptive Comfort Summary
Initialization Summary
Annual Heat Emissions Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
Coil Sizing Details
System Summary
Outdoor Air Summary
Outdoor Air Details
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary
Annual Thermal Resilience Summary
Annual CO2 Resilience Summary
Annual Visual Resilience Summary

NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR

| Environment |

NAMEHOLDERMONTHLYSUMMARY CODENAME IECC

| Environment |

NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2015

| Environment |

NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND

| Environment |

NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME OFFICESMALL

| Environment |

NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL

| Environment |

NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL

| Environment |

NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 5B

| Environment |

NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_CO_DENVER

| Environment |

ZoneCoolingSummaryMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

ZoneHeatingSummaryMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

ZoneElectricSummaryMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 |

SpaceGainsMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

PeakSpaceGainsMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

SpaceGainComponentsAtCoolingPeakMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

EnergyConsumptionElectricityNaturalGasMonthly

| Meter |

EndUseEnergyConsumptionElectricityMonthly

| Meter |

EndUseEnergyConsumptionNaturalGasMonthly

| Meter |

PeakEnergyEndUseElectricityPart1Monthly

| Meter |

PeakEnergyEndUseElectricityPart2Monthly

| Meter |

ElectricComponentsOfPeakDemandMonthly

| Meter |

PeakEnergyEndUseNaturalGasMonthly

| Meter |

SetpointsNotMetWithTemperaturesMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

ComfortReportSimple55Monthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

OccupantComfortDataSummaryMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 |

DXReportMonthly

| PSZ-AC:1 HP COOLING COIL | PSZ-AC:2 HP COOLING COIL | PSZ-AC:3 HP COOLING COIL | PSZ-AC:4 HP COOLING COIL | PSZ-AC:5 HP COOLING COIL |

WindowReportMonthly

| PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 | PERIMETER_ZN_1_WALL_SOUTH_DOOR | PERIMETER_ZN_2_WALL_EAST_WINDOW_4 | PERIMETER_ZN_2_WALL_EAST_WINDOW_3 | PERIMETER_ZN_2_WALL_EAST_WINDOW_2 | PERIMETER_ZN_2_WALL_EAST_WINDOW_1 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 | PERIMETER_ZN_4_WALL_WEST_WINDOW_4 | PERIMETER_ZN_4_WALL_WEST_WINDOW_3 | PERIMETER_ZN_4_WALL_WEST_WINDOW_2 | PERIMETER_ZN_4_WALL_WEST_WINDOW_1 |

WindowEnergyReportMonthly

| PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 | PERIMETER_ZN_1_WALL_SOUTH_DOOR | PERIMETER_ZN_2_WALL_EAST_WINDOW_4 | PERIMETER_ZN_2_WALL_EAST_WINDOW_3 | PERIMETER_ZN_2_WALL_EAST_WINDOW_2 | PERIMETER_ZN_2_WALL_EAST_WINDOW_1 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 | PERIMETER_ZN_4_WALL_WEST_WINDOW_4 | PERIMETER_ZN_4_WALL_WEST_WINDOW_3 | PERIMETER_ZN_4_WALL_WEST_WINDOW_2 | PERIMETER_ZN_4_WALL_WEST_WINDOW_1 |

WindowZoneSummaryMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

WindowEnergyZoneSummaryMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

AverageOutdoorConditionsMonthly

| Environment |

OutdoorConditionsMaximumDryBulbMonthly

| Environment |

OutdoorConditionsMinimumDryBulbMonthly

| Environment |

OutdoorConditionsMaximumWetBulbMonthly

| Environment |

OutdoorConditionsMaximumDewPointMonthly

| Environment |

OutdoorGroundConditionsMonthly

| Environment |

WaterHeaterReportMonthly

| SWHSYS1 WATER HEATER |

DaylightingReportMonthly

| PERIMETER_ZN_1_DAYLCTRL | PERIMETER_ZN_2_DAYLCTRL | PERIMETER_ZN_3_DAYLCTRL | PERIMETER_ZN_4_DAYLCTRL |

CoilReportMonthly

| PSZ-AC:1 HEATING COIL | PSZ-AC:2 HEATING COIL | PSZ-AC:3 HEATING COIL | PSZ-AC:4 HEATING COIL | PSZ-AC:5 HEATING COIL | PSZ-AC:1_SUPPHEATCOIL | PSZ-AC:2_SUPPHEATCOIL | PSZ-AC:3_SUPPHEATCOIL | PSZ-AC:4_SUPPHEATCOIL | PSZ-AC:5_SUPPHEATCOIL | PSZ-AC:1 HP COOLING COIL | PSZ-AC:2 HP COOLING COIL | PSZ-AC:3 HP COOLING COIL | PSZ-AC:4 HP COOLING COIL | PSZ-AC:5 HP COOLING COIL |

PlantLoopDemandReportMonthly

| SWHSYS1 |

FanReportMonthly

| PSZ-AC:1 FAN | PSZ-AC:2 FAN | PSZ-AC:3 FAN | PSZ-AC:4 FAN | PSZ-AC:5 FAN |

PumpReportMonthly

| SWHSYS1 PUMP |

CondLoopDemandReportMonthly

| SWHSYS1 |

ZoneTemperatureOscillationReportMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

AirLoopSystemEnergyAndWaterUseMonthly

| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 | PSZ-AC:5 |

AirLoopSystemComponentLoadsMonthly

| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 | PSZ-AC:5 |

AirLoopSystemComponentEnergyUseMonthly

| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 | PSZ-AC:5 |

MechanicalVentilationLoadsMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 |

HeatEmissionsReportMonthly

| Environment |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

General

Value
Program Version and Build EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 08:29
RunPeriod RUNPERIOD 1
Weather File Denver-Aurora-Buckley AFB CO USA TMY3 WMO#=724695
Latitude [deg] 39.72
Longitude [deg] -104.8
Elevation [m] 1726.00
Time Zone -7.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 281.51 84.45 56.30 84.45 56.30
Above Ground Wall Area [m2] 281.51 84.45 56.30 84.45 56.30
Window Opening Area [m2] 59.65 16.72 11.15 20.63 11.15
Gross Window-Wall Ratio [%] 21.19 19.80 19.80 24.43 19.80
Above Ground Window-Wall Ratio [%] 21.19 19.80 19.80 24.43 19.80


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 281.51 84.45 56.30 84.45 56.30
Above Ground Wall Area [m2] 281.51 84.45 56.30 84.45 56.30
Window Opening Area [m2] 59.65 16.72 11.15 20.63 11.15
Gross Window-Wall Ratio [%] 21.19 19.80 19.80 24.43 19.80
Above Ground Window-Wall Ratio [%] 21.19 19.80 19.80 24.43 19.80


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 598.76
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Above Ground Gross Wall Area [m2] Underground Gross Wall Area [m2] Window Glass Area [m2] Opening Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
CORE_ZN 149.66 Yes Yes 456.46 1.00 0.00 0.00 0.00 0.00 9.0375 18.58 6.7800
PERIMETER_ZN_1 113.45 Yes Yes 346.02 1.00 84.45 0.00 20.63 20.63 9.0375 18.58 6.7800
PERIMETER_ZN_2 67.30 Yes Yes 205.26 1.00 56.30 0.00 11.15 11.15 9.0375 18.58 6.7800
PERIMETER_ZN_3 113.45 Yes Yes 346.02 1.00 84.45 0.00 16.72 16.72 9.0375 18.58 6.7800
PERIMETER_ZN_4 67.30 Yes Yes 205.26 1.00 56.30 0.00 11.15 11.15 9.0375 18.58 6.7800
ATTIC 567.98 No No 720.19 1.00 0.00 0.00 0.00 0.00 0.0000   0.0000
Total 511.16     1559.03   281.51 0.00 59.65 59.65 9.0375 18.58 6.7800
Conditioned Total 511.16     1559.03   281.51 0.00 59.65 59.65 9.0375 18.58 6.7800
Unconditioned Total 0.00     0.00   0.00 0.00 0.00 0.00      
Not Part of Total 567.98     720.19   0.00 0.00 0.00 0.00 0.0000   0.0000


Space Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Multipliers Zone Name Space Type Radiant/Solar Enclosure Name Lighting [W/m2] People [m2 per person] Plug and Process [W/m2] Tags
CORE_ZN 149.66 Yes Yes 1.00 CORE_ZN GENERAL CORE_ZN 9.0375 18.58 6.7800  
PERIMETER_ZN_1 113.45 Yes Yes 1.00 PERIMETER_ZN_1 GENERAL PERIMETER_ZN_1 9.0375 18.58 6.7800  
PERIMETER_ZN_2 67.30 Yes Yes 1.00 PERIMETER_ZN_2 GENERAL PERIMETER_ZN_2 9.0375 18.58 6.7800  
PERIMETER_ZN_3 113.45 Yes Yes 1.00 PERIMETER_ZN_3 GENERAL PERIMETER_ZN_3 9.0375 18.58 6.7800  
PERIMETER_ZN_4 67.30 Yes Yes 1.00 PERIMETER_ZN_4 GENERAL PERIMETER_ZN_4 9.0375 18.58 6.7800  
ATTIC 567.98 No No 1.00 ATTIC GENERAL ATTIC 0.0000 0.00 0.0000  
Total 511.16             9.0375 9.29 6.7800  
Conditioned Total 511.16             9.0375 9.29 6.7800  
Unconditioned Total 0.00             0.0000 0.00 0.0000  
Not Part of Total 567.98             0.0000 0.00 0.0000  


Space Type Summary

Total Area [m2] Conditioned Area [m2] Unconditioned Area [m2] Not Part of Total Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
GENERAL 511.16 511.16 0.00 567.98 9.0375 18.58 6.7800
Total 511.16 511.16 0.00 567.98      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

End Uses

Electricity [W] Natural Gas [W] Gasoline [W] Diesel [W] Coal [W] Fuel Oil No 1 [W] Fuel Oil No 2 [W] Propane [W] Other Fuel 1 [W] Other Fuel 2 [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 20-MAR-07:00 22-DEC-07:10 - - - - - - - - - - 02-JAN-12:09
Heating 9217.07 33968.21 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 3078.47 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 3465.65 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 2211.29 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 2745.38 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                           
Total End Uses 20717.85 33968.21 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Gasoline [W] Diesel [W] Coal [W] Fuel Oil No 1 [W] Fuel Oil No 2 [W] Propane [W] Other Fuel 1 [W] Other Fuel 2 [W] District Cooling [W] Steam [W] Water [m3/s]
Heating General 9217.07 33968.21 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting LightsWired 3078.47 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 3465.65 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans General 2211.29 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  Water Heater 2745.38 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  WaterUse 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Gasoline [GJ] Source Diesel [GJ] Source Coal [GJ] Source Fuel Oil No 1 [GJ] Source Fuel Oil No 2 [GJ] Source Propane [GJ] Source Other Fuel 1 [GJ] Source Other Fuel 2 [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 50.98 12.13 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 46.37 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 133.39 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 65.54 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 167.22 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 85.60 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 79.10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Total Source Energy End Use Components 628.19 12.13 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Gasoline [MJ/m2] Source Diesel [MJ/m2] Source Coal [MJ/m2] Source Fuel Oil No 1 [MJ/m2] Source Fuel Oil No 2 [MJ/m2] Source Propane [MJ/m2] Source Other Fuel 1 [MJ/m2] Source Other Fuel 2 [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 99.74 23.73 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 90.71 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 260.95 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 128.21 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 327.13 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 167.47 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 154.74 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Total Source Energy End Use Components 1228.96 23.73 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Gasoline [MJ/m2] Source Diesel [MJ/m2] Source Coal [MJ/m2] Source Fuel Oil No 1 [MJ/m2] Source Fuel Oil No 2 [MJ/m2] Source Propane [MJ/m2] Source Other Fuel 1 [MJ/m2] Source Other Fuel 2 [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 99.74 23.73 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 90.71 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 260.95 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 128.21 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 327.13 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 167.47 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 154.74 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Total Source Energy End Use Components 1228.96 23.73 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

AirTerminal:SingleDuct:ConstantVolume:NoReheat

Design Size Maximum Air Flow Rate [m3/s]
CORE_ZN DIRECT AIR 0.395892
PERIMETER_ZN_1 DIRECT AIR 0.429462
PERIMETER_ZN_2 DIRECT AIR 0.334646
PERIMETER_ZN_3 DIRECT AIR 0.383406
PERIMETER_ZN_4 DIRECT AIR 0.430769
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

AirLoopHVAC

Sum of Air Terminal Maximum Heating Flow Rates [m3/s] Sum of Air Terminal Minimum Heating Flow Rates [m3/s] Sum of Air Terminal Maximum Flow Rates [m3/s] Adjusted Heating Design Air Flow Rate [m3/s] Adjusted Cooling Design Air Flow Rate [m3/s] Adjusted Main Design Air Flow Rate [m3/s] User Heating Air Flow Ratio [] Calculated Heating Air Flow Ratio [] Design Supply Air Flow Rate [m3/s]
PSZ-AC:1 0.395892 0.395892 0.395892 0.395892 0.395892 0.395892 1.00 1.00 0.395892
PSZ-AC:2 0.429462 0.429462 0.429462 0.429462 0.429462 0.429462 1.00 1.00 0.429462
PSZ-AC:3 0.334646 0.334646 0.334646 0.334646 0.334646 0.334646 1.00 1.00 0.334646
PSZ-AC:4 0.383406 0.383406 0.383406 0.383406 0.383406 0.383406 1.00 1.00 0.383406
PSZ-AC:5 0.430769 0.430769 0.430769 0.430769 0.430769 0.430769 1.00 1.000000 0.430769
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
PSZ-AC:1_OA_CONTROLLER 0.395892 0.064622
PSZ-AC:2_OA_CONTROLLER 0.429462 0.048988
PSZ-AC:3_OA_CONTROLLER 0.334646 0.029060
PSZ-AC:4_OA_CONTROLLER 0.383406 0.048988
PSZ-AC:5_OA_CONTROLLER 0.430769 0.029060
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Coil:Cooling:DX:SingleSpeed

Design Size Rated Air Flow Rate [m3/s] Design Size Gross Rated Total Cooling Capacity [W] Design Size Gross Rated Sensible Heat Ratio
PSZ-AC:1 HP COOLING COIL 0.395892 6553.42 0.800655
PSZ-AC:2 HP COOLING COIL 0.429462 7109.12 0.800655
PSZ-AC:3 HP COOLING COIL 0.334646 5539.57 0.800655
PSZ-AC:4 HP COOLING COIL 0.383406 6346.73 0.800655
PSZ-AC:5 HP COOLING COIL 0.430769 7130.76 0.800655
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

AirLoopHVAC:UnitaryHeatPump:AirToAir

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Maximum Supply Air Temperature from Supplemental Heater [C] Supplemental Heating Coil Nominal Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
PSZ-AC:1_UNITARY_PACKAGE_DX 0.395892 0.395892 0.395892 0.395892 6553.42 6553.42 40.00 4151.69 1.00
PSZ-AC:2_UNITARY_PACKAGE_DX 0.429462 0.429462 0.429462 0.429462 7109.12 7109.12 40.00 7107.91 1.00
PSZ-AC:3_UNITARY_PACKAGE_DX 0.334646 0.334646 0.334646 0.334646 5539.57 5539.57 40.00 4454.79 1.00
PSZ-AC:4_UNITARY_PACKAGE_DX 0.383406 0.383406 0.383406 0.383406 6346.73 6346.73 40.00 7005.39 1.00
PSZ-AC:5_UNITARY_PACKAGE_DX 0.430769 0.430769 0.430769 0.430769 7130.76 7130.76 40.00 4454.79 1.00
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Fan:OnOff

Design Size Maximum Flow Rate [m3/s]
PSZ-AC:1 FAN 0.395892
PSZ-AC:2 FAN 0.429462
PSZ-AC:3 FAN 0.334646
PSZ-AC:4 FAN 0.383406
PSZ-AC:5 FAN 0.430769
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Coil:Heating:DX:SingleSpeed

Design Size Rated Air Flow Rate [m3/s] Design Size Gross Rated Heating Capacity [W]
PSZ-AC:1 HEATING COIL 0.395892 6553.42
PSZ-AC:2 HEATING COIL 0.429462 7109.12
PSZ-AC:3 HEATING COIL 0.334646 5539.57
PSZ-AC:4 HEATING COIL 0.383406 6346.73
PSZ-AC:5 HEATING COIL 0.430769 7130.76
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Coil:Heating:Fuel

Design Size Nominal Capacity [W]
PSZ-AC:1_SUPPHEATCOIL 4151.69
PSZ-AC:2_SUPPHEATCOIL 7107.91
PSZ-AC:3_SUPPHEATCOIL 4454.79
PSZ-AC:4_SUPPHEATCOIL 7005.39
PSZ-AC:5_SUPPHEATCOIL 4454.79
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

PlantLoop

Maximum Loop Flow Rate [m3/s] Plant Loop Volume [m3]
SWHSYS1 0.000004 0.000486
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Pump:ConstantSpeed

Design Flow Rate [m3/s] Design Power Consumption [W]
SWHSYS1 PUMP 0.000004 0.000000
User-Specified values were used. Design Size values were used if no User-Specified values were provided.


Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

Possible Shadow Receivers
PERIMETER_ZN_1_WALL_SOUTH ATTIC_SOFFIT_WEST | ATTIC_SOFFIT_SOUTH | ATTIC_SOFFIT_EAST |
PERIMETER_ZN_2_WALL_EAST ATTIC_SOFFIT_SOUTH | ATTIC_SOFFIT_EAST | ATTIC_SOFFIT_NORTH |
PERIMETER_ZN_3_WALL_NORTH ATTIC_SOFFIT_WEST | ATTIC_SOFFIT_EAST | ATTIC_SOFFIT_NORTH |
PERIMETER_ZN_4_WALL_WEST ATTIC_SOFFIT_WEST | ATTIC_SOFFIT_SOUTH | ATTIC_SOFFIT_NORTH |


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
PERIMETER_ZN_1_WALL_SOUTH PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 | PERIMETER_ZN_1_WALL_SOUTH_DOOR |
PERIMETER_ZN_2_WALL_EAST PERIMETER_ZN_2_WALL_EAST_WINDOW_4 | PERIMETER_ZN_2_WALL_EAST_WINDOW_3 | PERIMETER_ZN_2_WALL_EAST_WINDOW_2 | PERIMETER_ZN_2_WALL_EAST_WINDOW_1 |
PERIMETER_ZN_3_WALL_NORTH PERIMETER_ZN_3_WALL_NORTH_DOOR1 | PERIMETER_ZN_3_WALL_NORTH_DOOR2 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 |
PERIMETER_ZN_4_WALL_WEST PERIMETER_ZN_4_WALL_WEST_WINDOW_4 | PERIMETER_ZN_4_WALL_WEST_WINDOW_3 | PERIMETER_ZN_4_WALL_WEST_WINDOW_2 | PERIMETER_ZN_4_WALL_WEST_WINDOW_1 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: Initialization Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

Version

Version ID
1 22.1


Timesteps per Hour

#TimeSteps Minutes per TimeStep {minutes}
1 6 10


System Convergence Limits

Minimum System TimeStep {minutes} Max HVAC Iterations Minimum Plant Iterations Maximum Plant Iterations
1 1 20 2 8


Simulation Control

Do Zone Sizing Do System Sizing Do Plant Sizing Do Design Days Do Weather Simulation Do HVAC Sizing Simulation
1 Yes Yes Yes No Yes No


Performance Precision Tradeoffs

Use Coil Direct Simulation Zone Radiant Exchange Algorithm Override Mode Number of Timestep In Hour Force Euler Method Minimum Number of Warmup Days Force Suppress All Begin Environment Resets Minimum System Timestep MaxZoneTempDiff MaxAllowedDelTemp
1 No ScriptF Normal 6 No 1 No 1.0 0.300 2.0000E-003


Output Reporting Tolerances

Tolerance for Time Heating Setpoint Not Met Tolerance for Zone Cooling Setpoint Not Met Time
1 0.556 0.556


Site:GroundTemperature:BuildingSurface

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00


Site:GroundTemperature:FCfactorMethod

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 7.10 3.00 -1.00 0.80 -0.20 4.80 6.10 13.70 22.20 22.70 21.70 18.50


Site:GroundTemperature:Shallow

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00


Site:GroundTemperature:Deep

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00


Site:GroundReflectance

Jan{dimensionless} Feb{dimensionless} Mar{dimensionless} Apr{dimensionless} May{dimensionless} Jun{dimensionless} Jul{dimensionless} Aug{dimensionless} Sep{dimensionless} Oct{dimensionless} Nov{dimensionless} Dec{dimensionless}
1 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20


Site:GroundReflectance:SnowModifier

Normal Daylighting {dimensionless}
1 1.000 1.000


Site:GroundReflectance:Snow

Jan{dimensionless} Feb{dimensionless} Mar{dimensionless} Apr{dimensionless} May{dimensionless} Jun{dimensionless} Jul{dimensionless} Aug{dimensionless} Sep{dimensionless} Oct{dimensionless} Nov{dimensionless} Dec{dimensionless}
1 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20


Site:GroundReflectance:Snow:Daylighting

Jan{dimensionless} Feb{dimensionless} Mar{dimensionless} Apr{dimensionless} May{dimensionless} Jun{dimensionless} Jul{dimensionless} Aug{dimensionless} Sep{dimensionless} Oct{dimensionless} Nov{dimensionless} Dec{dimensionless}
1 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20


Environment:Weather Station

Wind Sensor Height Above Ground {m} Wind Speed Profile Exponent {} Wind Speed Profile Boundary Layer Thickness {m} Air Temperature Sensor Height Above Ground {m} Wind Speed Modifier Coefficient-Internal Temperature Modifier Coefficient-Internal
1 10.000 0.140 270.000 1.500 1.586 9.750E-003


Site:Location

Location Name Latitude {N+/S- Deg} Longitude {E+/W- Deg} Time Zone Number {GMT+/-} Elevation {m} Standard Pressure at Elevation {Pa} Standard RhoAir at Elevation
1 Denver-Aurora-Buckley AFB CO USA TMY3 WMO#=724695 39.72 -104.75 -7.00 1726.00 82237 0.9774


Site Water Mains Temperature Information

Calculation Method{} Water Mains Temperature Schedule Name{} Annual Average Outdoor Air Temperature{C} Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} Fixed Default Water Mains Temperature{C}
1 Correlation NA 9.95 23.70 NA


Building Information

Building Name North Axis {deg} Terrain Loads Convergence Tolerance Value Temperature Convergence Tolerance Value Solar Distribution Maximum Number of Warmup Days Minimum Number of Warmup Days
1 OfficeSmall 0.000 City 4.00000E-002 0.20000 FullInteriorAndExterior 25 6


Inside Convection Algorithm

Algorithm {Simple
TARP
CeilingDiffuser
AdaptiveConvectionAlgorithm}
1 TARP


Outside Convection Algorithm

Algorithm {SimpleCombined
TARP
MoWitt
DOE-2
AdaptiveConvectionAlgorithm}
1 TARP


Sky Radiance Distribution

Value {Anisotropic}
1 Anisotropic


Zone Air Solution Algorithm

Value {ThirdOrderBackwardDifference
AnalyticalSolution
EulerMethod}
1 ThirdOrderBackwardDifference


Zone Air Carbon Dioxide Balance Simulation

Simulation {Yes/No} Carbon Dioxide Concentration
1 No N/A


Zone Air Generic Contaminant Balance Simulation

Simulation {Yes/No} Generic Contaminant Concentration
1 No N/A


Zone Air Mass Flow Balance Simulation

Enforce Mass Balance



Adjust Zone Mixing and Return {AdjustMixingOnly
AdjustReturnOnly
AdjustMixingThenReturn
AdjustReturnThenMixing
None}
Adjust Zone Infiltration {AddInfiltration
AdjustInfiltration
None}

Infiltration Zones {MixingSourceZonesOnly
AllZones}


1 No N/A N/A N/A


HVACSystemRootFindingAlgorithm

Value {RegulaFalsi
Bisection
BisectionThenRegulaFalsi
RegulaFalsiThenBisection}
1 RegulaFalsi


Environment:Site Atmospheric Variation

Wind Speed Profile Exponent {} Wind Speed Profile Boundary Layer Thickness {m} Air Temperature Gradient Coefficient {K/m}
1 0.330 460.000 6.500000E-003


Surface Geometry

Starting Corner Vertex Input Direction Coordinate System Daylight Reference Point Coordinate System Rectangular (Simple) Surface Coordinate System
1 UpperLeftCorner Counterclockwise RelativeCoordinateSystem RelativeCoordinateSystem RelativeToZoneOrigin


Surface Heat Transfer Algorithm

Value {CTF - ConductionTransferFunction
EMPD - MoisturePenetrationDepthConductionTransferFunction
CondFD - ConductionFiniteDifference
HAMT - CombinedHeatAndMoistureFiniteElement} - Description
Inside Surface Max Temperature Limit{C}


Surface Convection Coefficient Lower Limit {W/m2-K}


Surface Convection Coefficient Upper Limit {W/m2-K}


1 CTF - ConductionTransferFunction 200 0.10 1000.0


Shading Summary

Number of Fixed Detached Shades Number of Building Detached Shades Number of Attached Shades
1 0 0 0


Zone Summary

Number of Zones Number of Zone Surfaces Number of SubSurfaces
1 6 71 23


Zone Information

Zone Name North Axis {deg} Origin X-Coordinate {m} Origin Y-Coordinate {m} Origin Z-Coordinate {m} Centroid X-Coordinate {m} Centroid Y-Coordinate {m} Centroid Z-Coordinate {m} Type Zone Multiplier Zone List Multiplier Minimum X {m} Maximum X {m} Minimum Y {m} Maximum Y {m} Minimum Z {m} Maximum Z {m} Ceiling Height {m} Volume {m3} Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} Floor Area {m2} Exterior Gross Wall Area {m2} Exterior Net Wall Area {m2} Exterior Window Area {m2} Number of Surfaces Number of SubSurfaces Number of Shading SubSurfaces Part of Total Building Area
1 CORE_ZN 0.0 0.00 0.00 0.00 13.85 9.23 1.53 1 1 1 5.00 22.69 5.00 13.46 0.00 3.05 3.05 456.46 TARP TARP 149.66 0.00 0.00 0.00 6 0 0 Yes
2 PERIMETER_ZN_1 0.0 0.00 0.00 0.00 13.85 2.21 1.53 1 1 1 0.00 27.69 0.00 5.00 0.00 3.05 3.05 346.02 TARP TARP 113.45 84.45 63.82 20.63 6 7 0 Yes
3 PERIMETER_ZN_2 0.0 0.00 0.00 0.00 25.64 9.23 1.53 1 1 1 22.69 27.69 0.00 18.46 0.00 3.05 3.05 205.27 TARP TARP 67.30 56.30 45.15 11.15 6 4 0 Yes
4 PERIMETER_ZN_3 0.0 0.00 0.00 0.00 13.85 16.25 1.53 1 1 1 0.00 27.69 13.46 18.46 0.00 3.05 3.05 346.02 TARP TARP 113.45 84.45 63.83 16.72 6 8 0 Yes
5 PERIMETER_ZN_4 0.0 0.00 0.00 0.00 2.05 9.23 1.53 1 1 1 0.00 5.00 0.00 18.46 0.00 3.05 3.05 205.27 TARP TARP 67.30 56.30 45.15 11.15 6 4 0 Yes
6 ATTIC 0.0 0.00 0.00 0.00 13.85 9.23 3.70 1 1 1 -0.60 28.29 -0.60 19.06 3.05 6.33 1.64 720.19 TARP TARP 567.98 0.00 0.00 0.00 13 0 0 No


Zone Internal Gains Nominal

Zone Name Floor Area {m2} # Occupants Area per Occupant {m2/person} Occupant per Area {person/m2} Interior Lighting {W/m2} Electric Load {W/m2} Gas Load {W/m2} Other Load {W/m2} Hot Water Eq {W/m2} Steam Equipment {W/m2} Sum Loads per Area {W/m2} Outdoor Controlled Baseboard Heat
1 CORE_ZN 149.66 8.1 18.581 5.382E-002 9.038 6.780 0.000 0.000 0.000 0.000 15.818 No
2 PERIMETER_ZN_1 113.45 6.1 18.581 5.382E-002 9.038 6.780 0.000 0.000 0.000 0.000 15.818 No
3 PERIMETER_ZN_2 67.30 3.6 18.581 5.382E-002 9.038 6.780 0.000 0.000 0.000 0.000 15.818 No
4 PERIMETER_ZN_3 113.45 6.1 18.581 5.382E-002 9.038 6.780 0.000 0.000 0.000 0.000 15.818 No
5 PERIMETER_ZN_4 67.30 3.6 18.581 5.382E-002 9.038 6.780 0.000 0.000 0.000 0.000 15.818 No
6 ATTIC 567.98 0.0 N/A 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 No


People Internal Gains Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Number of People {} People/Floor Area {person/m2} Floor Area per person {m2/person} Fraction Radiant Fraction Convected Sensible Fraction Calculation Activity level ASHRAE 55 Warnings Carbon Dioxide Generation Rate Nominal Minimum Number of People Nominal Maximum Number of People
1 CORE_ZN BLDG_OCC_SCH_WO_SB CORE_ZN 149.66 8.1 8.1 5.382E-002 18.581 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 8
2 PERIMETER_ZN_1 BLDG_OCC_SCH_WO_SB PERIMETER_ZN_1 113.45 6.1 6.1 5.382E-002 18.581 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 6
3 PERIMETER_ZN_2 BLDG_OCC_SCH_W_SB PERIMETER_ZN_2 67.30 3.6 3.6 5.382E-002 18.581 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 4
4 PERIMETER_ZN_3 BLDG_OCC_SCH_WO_SB PERIMETER_ZN_3 113.45 6.1 6.1 5.382E-002 18.581 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 6
5 PERIMETER_ZN_4 BLDG_OCC_SCH_WO_SB PERIMETER_ZN_4 67.30 3.6 3.6 5.382E-002 18.581 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 4


Lights Internal Gains Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Lighting Level {W} Lights/Floor Area {W/m2} Lights per person {W/person} Fraction Return Air Fraction Radiant Fraction Short Wave Fraction Convected Fraction Replaceable End-Use Category Nominal Minimum Lighting Level {W} Nominal Maximum Lighting Level {W}
1 CORE_ZN_LIGHTS LTG_SCH_OFFICE CORE_ZN 149.66 8.1 1352.531 9.038 167.923 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 1352.531
2 PERIMETER_ZN_1_LIGHTS LTG_SCH_OFFICE PERIMETER_ZN_1 113.45 6.1 1025.306 9.038 167.923 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 1025.306
3 PERIMETER_ZN_2_LIGHTS LTG_SCH_OFFICE PERIMETER_ZN_2 67.30 3.6 608.225 9.038 167.923 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 608.225
4 PERIMETER_ZN_3_LIGHTS LTG_SCH_OFFICE PERIMETER_ZN_3 113.45 6.1 1025.306 9.038 167.923 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 1025.306
5 PERIMETER_ZN_4_LIGHTS LTG_SCH_OFFICE PERIMETER_ZN_4 67.30 3.6 608.225 9.038 167.923 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 608.225


ElectricEquipment Internal Gains Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Equipment Level {W} Equipment/Floor Area {W/m2} Equipment per person {W/person} Fraction Latent Fraction Radiant Fraction Lost Fraction Convected End-Use SubCategory Nominal Minimum Equipment Level {W} Nominal Maximum Equipment Level {W}
1 CORE_ZN_MISCPLUG_EQUIP BLDG_EQUIP_SCH CORE_ZN 149.66 8.1 1014.677 6.780 125.977 0.000 0.000 0.000 1.000 MiscPlug 0.000 1014.677
2 PERIMETER_ZN_1_MISCPLUG_EQUIP BLDG_EQUIP_SCH PERIMETER_ZN_1 113.45 6.1 769.191 6.780 125.977 0.000 0.000 0.000 1.000 MiscPlug 0.000 769.191
3 PERIMETER_ZN_2_MISCPLUG_EQUIP BLDG_EQUIP_SCH PERIMETER_ZN_2 67.30 3.6 456.294 6.780 125.977 0.000 0.000 0.000 1.000 MiscPlug 0.000 456.294
4 PERIMETER_ZN_3_MISCPLUG_EQUIP BLDG_EQUIP_SCH PERIMETER_ZN_3 113.45 6.1 769.191 6.780 125.977 0.000 0.000 0.000 1.000 MiscPlug 0.000 769.191
5 PERIMETER_ZN_4_MISCPLUG_EQUIP BLDG_EQUIP_SCH PERIMETER_ZN_4 67.30 3.6 456.294 6.780 125.977 0.000 0.000 0.000 1.000 MiscPlug 0.000 456.294


Shadowing/Sun Position Calculations Annual Simulations

Shading Calculation Method Shading Calculation Update Frequency Method Shading Calculation Update Frequency {days} Maximum Figures in Shadow Overlap Calculations {} Polygon Clipping Algorithm Pixel Counting Resolution Sky Diffuse Modeling Algorithm Output External Shading Calculation Results Disable Self-Shading Within Shading Zone Groups Disable Self-Shading From Shading Zone Groups to Other Zones
1 PolygonClipping Periodic 30 15000 SutherlandHodgman 512 SimpleSkyDiffuseModeling No No No


Enclosure/Window Adjacency Daylighting Counts

Enclosure Name Number of Exterior Windows Number of Exterior Windows in Adjacent Enclosures
1 PERIMETER_ZN_1 7 0
2 PERIMETER_ZN_2 4 0
3 PERIMETER_ZN_3 6 0
4 PERIMETER_ZN_4 4 0


Enclosure/Window Adjacency Daylighting Matrix

Enclosure Name Number of Adjacent Enclosures with Windows Adjacent Enclosure Names - 1st 100 (max)
1 PERIMETER_ZN_1 0  
2 PERIMETER_ZN_2 0  
3 PERIMETER_ZN_3 0  
4 PERIMETER_ZN_4 0  


Water Heater Information

Type Name Volume {m3} Maximum Capacity {W} Standard Rated Recovery Efficiency Standard Rated Energy Factor
1 WaterHeater:Mixed SWHSYS1 WATER HEATER 0.1514 11722.8 0.981 0.4606


ZoneInfiltration Airflow Stats Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Design Volume Flow Rate {m3/s} Volume Flow Rate/Floor Area {m3/s-m2} Volume Flow Rate/Exterior Surface Area {m3/s-m2} ACH - Air Changes per Hour Equation A - Constant Term Coefficient {} Equation B - Temperature Term Coefficient {1/C} Equation C - Velocity Term Coefficient {s/m} Equation D - Velocity Squared Term Coefficient {s2/m2}
1 PERIMETER_ZN_1_INFILTRATION INFIL_QUARTER_ON_SCH PERIMETER_ZN_1 113.45 6.1 4.810E-002 4.240E-004 5.696E-004 0.500 0.000 0.000 0.224 0.000
2 PERIMETER_ZN_1_DOOR_INFILTRATION INFIL_DOOR_OPENING_SCH PERIMETER_ZN_1 113.45 6.1 0.130 1.144E-003 1.537E-003 1.350 1.000 0.000 0.000 0.000
3 PERIMETER_ZN_2_INFILTRATION INFIL_QUARTER_ON_SCH PERIMETER_ZN_2 67.30 3.6 3.207E-002 4.765E-004 5.696E-004 0.562 0.000 0.000 0.224 0.000
4 PERIMETER_ZN_3_INFILTRATION INFIL_QUARTER_ON_SCH PERIMETER_ZN_3 113.45 6.1 4.810E-002 4.240E-004 5.444E-004 0.500 0.000 0.000 0.224 0.000
5 PERIMETER_ZN_4_INFILTRATION INFIL_QUARTER_ON_SCH PERIMETER_ZN_4 67.30 3.6 3.207E-002 4.765E-004 5.696E-004 0.562 0.000 0.000 0.224 0.000
6 ATTIC_INFILTRATION ALWAYS_ON ATTIC 567.98 0.0 0.200 3.523E-004 3.052E-004 1.000 1.000 0.000 0.000 0.000


AirFlow Model

Simple
1 Simple


RoomAir Model

Zone Name Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined
1 CORE_ZN Mixing/Well-Stirred
2 PERIMETER_ZN_1 Mixing/Well-Stirred
3 PERIMETER_ZN_2 Mixing/Well-Stirred
4 PERIMETER_ZN_3 Mixing/Well-Stirred
5 PERIMETER_ZN_4 Mixing/Well-Stirred
6 ATTIC Mixing/Well-Stirred


AirflowNetwork Model:Control

No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation
1 NoMultizoneOrDistribution


Zone Volume Capacitance Multiplier

Sensible Heat Capacity Multiplier Moisture Capacity Multiplier Carbon Dioxide Capacity Multiplier Generic Contaminant Capacity Multiplier
1 1.000 1.000 1.000 1.000


Load Timesteps in Zone Design Calculation Averaging Window

Value
1 6


Heating Sizing Factor Information

Sizing Factor ID Value
1 Global 1.2000
2 Zone CORE_ZN 1.2000
3 Zone PERIMETER_ZN_1 1.2000
4 Zone PERIMETER_ZN_2 1.2000
5 Zone PERIMETER_ZN_3 1.2000
6 Zone PERIMETER_ZN_4 1.2000


Cooling Sizing Factor Information

Sizing Factor ID Value
1 Global 1.2000
2 Zone CORE_ZN 1.2000
3 Zone PERIMETER_ZN_1 1.2000
4 Zone PERIMETER_ZN_2 1.2000
5 Zone PERIMETER_ZN_3 1.2000
6 Zone PERIMETER_ZN_4 1.2000


Sky Daylight Factors

Sky Type MonthAndDay Daylighting Control Name Enclosure Name Window Name Reference Point Daylight Factor
1 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 PERIMETER_ZN_1_DAYLREFPT1 1.9900E-003
2 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 PERIMETER_ZN_1_DAYLREFPT2 2.2203E-003
3 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 PERIMETER_ZN_1_DAYLREFPT1 2.1917E-003
4 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 PERIMETER_ZN_1_DAYLREFPT2 2.4047E-003
5 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 PERIMETER_ZN_1_DAYLREFPT1 1.3123E-003
6 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 PERIMETER_ZN_1_DAYLREFPT2 1.4807E-003
7 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 PERIMETER_ZN_1_DAYLREFPT1 6.2391E-004
8 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 PERIMETER_ZN_1_DAYLREFPT2 6.9699E-004
9 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 PERIMETER_ZN_1_DAYLREFPT1 1.2243E-002
10 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 PERIMETER_ZN_1_DAYLREFPT2 1.2129E-002
11 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 PERIMETER_ZN_1_DAYLREFPT1 1.2499E-002
12 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 PERIMETER_ZN_1_DAYLREFPT2 1.3198E-002
13 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 PERIMETER_ZN_1_DAYLREFPT1 1.1098E-002
14 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 PERIMETER_ZN_1_DAYLREFPT2 7.7568E-003
15 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 PERIMETER_ZN_1_DAYLREFPT1 5.3217E-003
16 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 PERIMETER_ZN_1_DAYLREFPT2 2.8839E-003
17 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 PERIMETER_ZN_1_DAYLREFPT1 9.6784E-003
18 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 PERIMETER_ZN_1_DAYLREFPT2 1.0285E-002
19 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 PERIMETER_ZN_1_DAYLREFPT1 9.7398E-003
20 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 PERIMETER_ZN_1_DAYLREFPT2 1.1017E-002
21 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 PERIMETER_ZN_1_DAYLREFPT1 8.8977E-003
22 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 PERIMETER_ZN_1_DAYLREFPT2 6.8917E-003
23 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 PERIMETER_ZN_1_DAYLREFPT1 4.4181E-003
24 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 PERIMETER_ZN_1_DAYLREFPT2 2.6644E-003
25 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 PERIMETER_ZN_1_DAYLREFPT1 1.9775E-003
26 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 PERIMETER_ZN_1_DAYLREFPT2 2.1796E-003
27 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 PERIMETER_ZN_1_DAYLREFPT1 2.1803E-003
28 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 PERIMETER_ZN_1_DAYLREFPT2 2.3652E-003
29 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 PERIMETER_ZN_1_DAYLREFPT1 1.3017E-003
30 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 PERIMETER_ZN_1_DAYLREFPT2 1.4513E-003
31 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 PERIMETER_ZN_1_DAYLREFPT1 6.1885E-004
32 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 PERIMETER_ZN_1_DAYLREFPT2 6.8572E-004
33 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 PERIMETER_ZN_1_DAYLREFPT1 1.9012E-003
34 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 PERIMETER_ZN_1_DAYLREFPT2 1.9229E-003
35 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 PERIMETER_ZN_1_DAYLREFPT1 2.1143E-003
36 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 PERIMETER_ZN_1_DAYLREFPT2 2.1332E-003
37 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 PERIMETER_ZN_1_DAYLREFPT1 1.2403E-003
38 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 PERIMETER_ZN_1_DAYLREFPT2 1.2556E-003
39 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 PERIMETER_ZN_1_DAYLREFPT1 5.8403E-004
40 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 PERIMETER_ZN_1_DAYLREFPT2 5.9168E-004
41 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 PERIMETER_ZN_1_DAYLREFPT1 1.8956E-003
42 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 PERIMETER_ZN_1_DAYLREFPT2 1.8998E-003
43 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 PERIMETER_ZN_1_DAYLREFPT1 2.1096E-003
44 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 PERIMETER_ZN_1_DAYLREFPT2 2.1132E-003
45 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 PERIMETER_ZN_1_DAYLREFPT1 1.2363E-003
46 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 PERIMETER_ZN_1_DAYLREFPT2 1.2392E-003
47 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 PERIMETER_ZN_1_DAYLREFPT1 5.8177E-004
48 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 PERIMETER_ZN_1_DAYLREFPT2 5.8325E-004
49 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_DOOR PERIMETER_ZN_1_DAYLREFPT1 2.9556E-003
50 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_DOOR PERIMETER_ZN_1_DAYLREFPT2 3.5199E-003
51 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_DOOR PERIMETER_ZN_1_DAYLREFPT1 3.1949E-003
52 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_DOOR PERIMETER_ZN_1_DAYLREFPT2 3.7501E-003
53 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_DOOR PERIMETER_ZN_1_DAYLREFPT1 2.0171E-003
54 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_DOOR PERIMETER_ZN_1_DAYLREFPT2 2.3822E-003
55 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_DOOR PERIMETER_ZN_1_DAYLREFPT1 9.8810E-004
56 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_DOOR PERIMETER_ZN_1_DAYLREFPT2 1.1098E-003
57 Clear Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_4 PERIMETER_ZN_2_DAYLREFPT1 1.3460E-003
58 Clear Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_4 PERIMETER_ZN_2_DAYLREFPT2 1.5087E-003
59 Clear Turbid Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_4 PERIMETER_ZN_2_DAYLREFPT1 1.2229E-003
60 Clear Turbid Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_4 PERIMETER_ZN_2_DAYLREFPT2 1.3421E-003
61 Intermediate Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_4 PERIMETER_ZN_2_DAYLREFPT1 1.1587E-003
62 Intermediate Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_4 PERIMETER_ZN_2_DAYLREFPT2 1.2129E-003
63 Overcast Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_4 PERIMETER_ZN_2_DAYLREFPT1 9.7899E-004
64 Overcast Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_4 PERIMETER_ZN_2_DAYLREFPT2 1.0462E-003
65 Clear Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_3 PERIMETER_ZN_2_DAYLREFPT1 5.5539E-003
66 Clear Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_3 PERIMETER_ZN_2_DAYLREFPT2 4.3104E-003
67 Clear Turbid Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_3 PERIMETER_ZN_2_DAYLREFPT1 4.4121E-003
68 Clear Turbid Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_3 PERIMETER_ZN_2_DAYLREFPT2 3.5197E-003
69 Intermediate Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_3 PERIMETER_ZN_2_DAYLREFPT1 3.8569E-003
70 Intermediate Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_3 PERIMETER_ZN_2_DAYLREFPT2 3.0854E-003
71 Overcast Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_3 PERIMETER_ZN_2_DAYLREFPT1 4.7833E-003
72 Overcast Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_3 PERIMETER_ZN_2_DAYLREFPT2 3.0613E-003
73 Clear Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_2 PERIMETER_ZN_2_DAYLREFPT1 1.3648E-002
74 Clear Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_2 PERIMETER_ZN_2_DAYLREFPT2 6.5607E-003
75 Clear Turbid Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_2 PERIMETER_ZN_2_DAYLREFPT1 1.4063E-002
76 Clear Turbid Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_2 PERIMETER_ZN_2_DAYLREFPT2 6.1587E-003
77 Intermediate Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_2 PERIMETER_ZN_2_DAYLREFPT1 1.1848E-002
78 Intermediate Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_2 PERIMETER_ZN_2_DAYLREFPT2 5.8758E-003
79 Overcast Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_2 PERIMETER_ZN_2_DAYLREFPT1 5.7060E-003
80 Overcast Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_2 PERIMETER_ZN_2_DAYLREFPT2 3.2877E-003
81 Clear Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_1 PERIMETER_ZN_2_DAYLREFPT1 1.6050E-003
82 Clear Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_1 PERIMETER_ZN_2_DAYLREFPT2 1.9931E-003
83 Clear Turbid Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_1 PERIMETER_ZN_2_DAYLREFPT1 1.5521E-003
84 Clear Turbid Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_1 PERIMETER_ZN_2_DAYLREFPT2 1.9527E-003
85 Intermediate Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_1 PERIMETER_ZN_2_DAYLREFPT1 1.2788E-003
86 Intermediate Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_1 PERIMETER_ZN_2_DAYLREFPT2 1.5000E-003
87 Overcast Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_1 PERIMETER_ZN_2_DAYLREFPT1 9.8388E-004
88 Overcast Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_1 PERIMETER_ZN_2_DAYLREFPT2 1.0575E-003
89 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 PERIMETER_ZN_3_DAYLREFPT1 7.0525E-004
90 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 PERIMETER_ZN_3_DAYLREFPT2 8.4030E-004
91 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 PERIMETER_ZN_3_DAYLREFPT1 5.6476E-004
92 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 PERIMETER_ZN_3_DAYLREFPT2 6.6881E-004
93 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 PERIMETER_ZN_3_DAYLREFPT1 4.6880E-004
94 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 PERIMETER_ZN_3_DAYLREFPT2 5.3651E-004
95 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 PERIMETER_ZN_3_DAYLREFPT1 6.1757E-004
96 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 PERIMETER_ZN_3_DAYLREFPT2 6.8147E-004
97 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 PERIMETER_ZN_3_DAYLREFPT1 4.3972E-003
98 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 PERIMETER_ZN_3_DAYLREFPT2 3.7458E-003
99 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 PERIMETER_ZN_3_DAYLREFPT1 3.4282E-003
100 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 PERIMETER_ZN_3_DAYLREFPT2 2.8316E-003
101 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 PERIMETER_ZN_3_DAYLREFPT1 3.2406E-003
102 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 PERIMETER_ZN_3_DAYLREFPT2 1.9275E-003
103 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 PERIMETER_ZN_3_DAYLREFPT1 4.0317E-003
104 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 PERIMETER_ZN_3_DAYLREFPT2 2.5609E-003
105 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 PERIMETER_ZN_3_DAYLREFPT1 6.0237E-003
106 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 PERIMETER_ZN_3_DAYLREFPT2 4.3435E-003
107 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 PERIMETER_ZN_3_DAYLREFPT1 4.6778E-003
108 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 PERIMETER_ZN_3_DAYLREFPT2 3.2721E-003
109 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 PERIMETER_ZN_3_DAYLREFPT1 4.4969E-003
110 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 PERIMETER_ZN_3_DAYLREFPT2 2.2120E-003
111 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 PERIMETER_ZN_3_DAYLREFPT1 5.8443E-003
112 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 PERIMETER_ZN_3_DAYLREFPT2 2.9995E-003
113 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 PERIMETER_ZN_3_DAYLREFPT1 7.2274E-004
114 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 PERIMETER_ZN_3_DAYLREFPT2 8.8147E-004
115 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 PERIMETER_ZN_3_DAYLREFPT1 5.7903E-004
116 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 PERIMETER_ZN_3_DAYLREFPT2 7.0134E-004
117 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 PERIMETER_ZN_3_DAYLREFPT1 4.8216E-004
118 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 PERIMETER_ZN_3_DAYLREFPT2 5.6242E-004
119 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 PERIMETER_ZN_3_DAYLREFPT1 6.2774E-004
120 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 PERIMETER_ZN_3_DAYLREFPT2 7.0407E-004
121 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 PERIMETER_ZN_3_DAYLREFPT1 6.4480E-004
122 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 PERIMETER_ZN_3_DAYLREFPT2 6.6464E-004
123 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 PERIMETER_ZN_3_DAYLREFPT1 5.1622E-004
124 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 PERIMETER_ZN_3_DAYLREFPT2 5.3196E-004
125 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 PERIMETER_ZN_3_DAYLREFPT1 4.2797E-004
126 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 PERIMETER_ZN_3_DAYLREFPT2 4.3911E-004
127 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 PERIMETER_ZN_3_DAYLREFPT1 5.8531E-004
128 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 PERIMETER_ZN_3_DAYLREFPT2 5.9381E-004
129 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 PERIMETER_ZN_3_DAYLREFPT1 6.3900E-004
130 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 PERIMETER_ZN_3_DAYLREFPT2 6.4299E-004
131 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 PERIMETER_ZN_3_DAYLREFPT1 5.1151E-004
132 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 PERIMETER_ZN_3_DAYLREFPT2 5.1471E-004
133 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 PERIMETER_ZN_3_DAYLREFPT1 4.2423E-004
134 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 PERIMETER_ZN_3_DAYLREFPT2 4.2654E-004
135 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 PERIMETER_ZN_3_DAYLREFPT1 5.8274E-004
136 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 PERIMETER_ZN_3_DAYLREFPT2 5.8434E-004
137 Clear Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_4 PERIMETER_ZN_4_DAYLREFPT1 1.6545E-003
138 Clear Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_4 PERIMETER_ZN_4_DAYLREFPT2 2.0547E-003
139 Clear Turbid Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_4 PERIMETER_ZN_4_DAYLREFPT1 1.6132E-003
140 Clear Turbid Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_4 PERIMETER_ZN_4_DAYLREFPT2 2.0292E-003
141 Intermediate Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_4 PERIMETER_ZN_4_DAYLREFPT1 1.3052E-003
142 Intermediate Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_4 PERIMETER_ZN_4_DAYLREFPT2 1.5282E-003
143 Overcast Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_4 PERIMETER_ZN_4_DAYLREFPT1 9.8548E-004
144 Overcast Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_4 PERIMETER_ZN_4_DAYLREFPT2 1.0586E-003
145 Clear Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_3 PERIMETER_ZN_4_DAYLREFPT1 1.4114E-002
146 Clear Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_3 PERIMETER_ZN_4_DAYLREFPT2 6.6762E-003
147 Clear Turbid Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_3 PERIMETER_ZN_4_DAYLREFPT1 1.4640E-002
148 Clear Turbid Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_3 PERIMETER_ZN_4_DAYLREFPT2 6.3117E-003
149 Intermediate Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_3 PERIMETER_ZN_4_DAYLREFPT1 1.2014E-002
150 Intermediate Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_3 PERIMETER_ZN_4_DAYLREFPT2 5.9054E-003
151 Overcast Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_3 PERIMETER_ZN_4_DAYLREFPT1 5.6833E-003
152 Overcast Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_3 PERIMETER_ZN_4_DAYLREFPT2 3.2455E-003
153 Clear Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_2 PERIMETER_ZN_4_DAYLREFPT1 5.5690E-003
154 Clear Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_2 PERIMETER_ZN_4_DAYLREFPT2 4.2805E-003
155 Clear Turbid Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_2 PERIMETER_ZN_4_DAYLREFPT1 4.4461E-003
156 Clear Turbid Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_2 PERIMETER_ZN_4_DAYLREFPT2 3.5175E-003
157 Intermediate Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_2 PERIMETER_ZN_4_DAYLREFPT1 3.9324E-003
158 Intermediate Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_2 PERIMETER_ZN_4_DAYLREFPT2 3.1165E-003
159 Overcast Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_2 PERIMETER_ZN_4_DAYLREFPT1 4.7796E-003
160 Overcast Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_2 PERIMETER_ZN_4_DAYLREFPT2 3.0259E-003
161 Clear Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_1 PERIMETER_ZN_4_DAYLREFPT1 1.3734E-003
162 Clear Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_1 PERIMETER_ZN_4_DAYLREFPT2 1.5340E-003
163 Clear Turbid Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_1 PERIMETER_ZN_4_DAYLREFPT1 1.2558E-003
164 Clear Turbid Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_1 PERIMETER_ZN_4_DAYLREFPT2 1.3738E-003
165 Intermediate Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_1 PERIMETER_ZN_4_DAYLREFPT1 1.1789E-003
166 Intermediate Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_1 PERIMETER_ZN_4_DAYLREFPT2 1.2339E-003
167 Overcast Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_1 PERIMETER_ZN_4_DAYLREFPT1 9.8042E-004
168 Overcast Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_1 PERIMETER_ZN_4_DAYLREFPT2 1.0473E-003


Zone Sizing Information

Zone Name Load Type Calc Des Load {W} User Des Load {W} Calc Des Air Flow Rate {m3/s} User Des Air Flow Rate {m3/s} Design Day Name Date/Time of Peak Temperature at Peak {C} Humidity Ratio at Peak {kgWater/kgDryAir} Floor Area {m2} # Occupants Calc Outdoor Air Flow Rate {m3/s} Calc DOAS Heat Addition Rate {W}
1 CORE_ZN Cooling 3649.76271 4379.71525 0.32991 0.39589 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 16:10:00 32.81467 5.47359E-003 149.65740 8.05449 6.46221E-002 0.00000
2 CORE_ZN Heating 1417.04593 1700.45512 7.52637E-002 9.03164E-002 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 -17.90000 9.55238E-004 149.65740 8.05449 6.46221E-002 0.00000
3 PERIMETER_ZN_1 Cooling 3959.20477 4751.04573 0.35788 0.42946 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 33.90000 5.47527E-003 113.45000 6.10582 4.89877E-002 0.00000
4 PERIMETER_ZN_1 Heating 4423.58644 5308.30372 0.23494 0.28193 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 -17.90000 9.55238E-004 113.45000 6.10582 4.89877E-002 0.00000
5 PERIMETER_ZN_2 Cooling 3085.22670 3702.27204 0.27887 0.33465 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 09:50:00 27.85667 5.46603E-003 67.30000 3.62205 2.90601E-002 0.00000
6 PERIMETER_ZN_2 Heating 2825.63342 3390.76010 0.15007 0.18009 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 -17.90000 9.55238E-004 67.30000 3.62205 2.90601E-002 0.00000
7 PERIMETER_ZN_3 Cooling 3534.68535 4241.62242 0.31950 0.38341 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:50:00 33.16000 5.47412E-003 113.45000 6.10582 4.89877E-002 0.00000
8 PERIMETER_ZN_3 Heating 4336.88593 5204.26312 0.23034 0.27640 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 -17.90000 9.55238E-004 113.45000 6.10582 4.89877E-002 0.00000
9 PERIMETER_ZN_4 Cooling 3971.41146 4765.69376 0.35897 0.43077 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:50:00 30.59467 5.47019E-003 67.30000 3.62205 2.90601E-002 0.00000
10 PERIMETER_ZN_4 Heating 2825.63342 3390.76010 0.15007 0.18009 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 -17.90000 9.55238E-004 67.30000 3.62205 2.90601E-002 0.00000


System Sizing Information

System Name Load Type Peak Load Kind User Design Capacity Calc Des Air Flow Rate [m3/s] User Des Air Flow Rate [m3/s] Design Day Name Date/Time of Peak
1 PSZ-AC:1 Cooling Sensible 4878.49 0.39589 0.39589 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
2 PSZ-AC:1 Heating Sensible 4151.69 9.03164E-002 9.03164E-002 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00
3 PSZ-AC:2 Cooling Sensible 5159.25 0.42946 0.42946 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
4 PSZ-AC:2 Heating Sensible 7107.91 0.28193 0.28193 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00
5 PSZ-AC:3 Cooling Sensible 3758.25 0.33465 0.33465 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
6 PSZ-AC:3 Heating Sensible 4454.79 0.18009 0.18009 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00
7 PSZ-AC:4 Cooling Sensible 4622.08 0.38341 0.38341 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
8 PSZ-AC:4 Heating Sensible 7005.39 0.27640 0.27640 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00
9 PSZ-AC:5 Cooling Sensible 4883.38 0.43077 0.43077 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
10 PSZ-AC:5 Heating Sensible 4454.79 0.18009 0.18009 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00


Component Sizing Information

Component Type Component Name Input Field Description Value
1 AirTerminal:SingleDuct:ConstantVolume:NoReheat CORE_ZN DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.39589
2 AirTerminal:SingleDuct:ConstantVolume:NoReheat PERIMETER_ZN_1 DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.42946
3 AirTerminal:SingleDuct:ConstantVolume:NoReheat PERIMETER_ZN_2 DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.33465
4 AirTerminal:SingleDuct:ConstantVolume:NoReheat PERIMETER_ZN_3 DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.38341
5 AirTerminal:SingleDuct:ConstantVolume:NoReheat PERIMETER_ZN_4 DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.43077
6 AirLoopHVAC PSZ-AC:1 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.39589
7 AirLoopHVAC PSZ-AC:1 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.39589
8 AirLoopHVAC PSZ-AC:1 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.39589
9 AirLoopHVAC PSZ-AC:1 Adjusted Heating Design Air Flow Rate [m3/s] 0.39589
10 AirLoopHVAC PSZ-AC:1 Adjusted Cooling Design Air Flow Rate [m3/s] 0.39589
11 AirLoopHVAC PSZ-AC:1 Adjusted Main Design Air Flow Rate [m3/s] 0.39589
12 AirLoopHVAC PSZ-AC:1 User Heating Air Flow Ratio [] 1.00000
13 AirLoopHVAC PSZ-AC:1 Calculated Heating Air Flow Ratio [] 1.00000
14 AirLoopHVAC PSZ-AC:2 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.42946
15 AirLoopHVAC PSZ-AC:2 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.42946
16 AirLoopHVAC PSZ-AC:2 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.42946
17 AirLoopHVAC PSZ-AC:2 Adjusted Heating Design Air Flow Rate [m3/s] 0.42946
18 AirLoopHVAC PSZ-AC:2 Adjusted Cooling Design Air Flow Rate [m3/s] 0.42946
19 AirLoopHVAC PSZ-AC:2 Adjusted Main Design Air Flow Rate [m3/s] 0.42946
20 AirLoopHVAC PSZ-AC:2 User Heating Air Flow Ratio [] 1.00000
21 AirLoopHVAC PSZ-AC:2 Calculated Heating Air Flow Ratio [] 1.00000
22 AirLoopHVAC PSZ-AC:3 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.33465
23 AirLoopHVAC PSZ-AC:3 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.33465
24 AirLoopHVAC PSZ-AC:3 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.33465
25 AirLoopHVAC PSZ-AC:3 Adjusted Heating Design Air Flow Rate [m3/s] 0.33465
26 AirLoopHVAC PSZ-AC:3 Adjusted Cooling Design Air Flow Rate [m3/s] 0.33465
27 AirLoopHVAC PSZ-AC:3 Adjusted Main Design Air Flow Rate [m3/s] 0.33465
28 AirLoopHVAC PSZ-AC:3 User Heating Air Flow Ratio [] 1.00000
29 AirLoopHVAC PSZ-AC:3 Calculated Heating Air Flow Ratio [] 1.00000
30 AirLoopHVAC PSZ-AC:4 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.38341
31 AirLoopHVAC PSZ-AC:4 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.38341
32 AirLoopHVAC PSZ-AC:4 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.38341
33 AirLoopHVAC PSZ-AC:4 Adjusted Heating Design Air Flow Rate [m3/s] 0.38341
34 AirLoopHVAC PSZ-AC:4 Adjusted Cooling Design Air Flow Rate [m3/s] 0.38341
35 AirLoopHVAC PSZ-AC:4 Adjusted Main Design Air Flow Rate [m3/s] 0.38341
36 AirLoopHVAC PSZ-AC:4 User Heating Air Flow Ratio [] 1.00000
37 AirLoopHVAC PSZ-AC:4 Calculated Heating Air Flow Ratio [] 1.00000
38 AirLoopHVAC PSZ-AC:5 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.43077
39 AirLoopHVAC PSZ-AC:5 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.43077
40 AirLoopHVAC PSZ-AC:5 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.43077
41 AirLoopHVAC PSZ-AC:5 Adjusted Heating Design Air Flow Rate [m3/s] 0.43077
42 AirLoopHVAC PSZ-AC:5 Adjusted Cooling Design Air Flow Rate [m3/s] 0.43077
43 AirLoopHVAC PSZ-AC:5 Adjusted Main Design Air Flow Rate [m3/s] 0.43077
44 AirLoopHVAC PSZ-AC:5 User Heating Air Flow Ratio [] 1.00000
45 AirLoopHVAC PSZ-AC:5 Calculated Heating Air Flow Ratio [] 1.00000
46 AirLoopHVAC PSZ-AC:1 Design Supply Air Flow Rate [m3/s] 0.39589
47 AirLoopHVAC PSZ-AC:2 Design Supply Air Flow Rate [m3/s] 0.42946
48 AirLoopHVAC PSZ-AC:3 Design Supply Air Flow Rate [m3/s] 0.33465
49 AirLoopHVAC PSZ-AC:4 Design Supply Air Flow Rate [m3/s] 0.38341
50 AirLoopHVAC PSZ-AC:5 Design Supply Air Flow Rate [m3/s] 0.43077
51 Controller:OutdoorAir PSZ-AC:1_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.39589
52 Controller:OutdoorAir PSZ-AC:1_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 6.46221E-002
53 Coil:Cooling:DX:SingleSpeed PSZ-AC:1 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.39589
54 Coil:Cooling:DX:SingleSpeed PSZ-AC:1 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 6553.41806
55 Coil:Cooling:DX:SingleSpeed PSZ-AC:1 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
56 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Supply Air Flow Rate [m3/s] 0.39589
57 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Supply Air Flow Rate During Heating Operation [m3/s] 0.39589
58 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Supply Air Flow Rate During Cooling Operation [m3/s] 0.39589
59 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] 0.39589
60 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Nominal Heating Capacity [W] 6553.41806
61 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Nominal Cooling Capacity [W] 6553.41806
62 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Maximum Supply Air Temperature from Supplemental Heater [C] 40.00000
63 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Supplemental Heating Coil Nominal Capacity [W] 4151.68727
64 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
65 Fan:OnOff PSZ-AC:1 FAN Design Size Maximum Flow Rate [m3/s] 0.39589
66 Coil:Heating:DX:SingleSpeed PSZ-AC:1 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.39589
67 Coil:Heating:DX:SingleSpeed PSZ-AC:1 HEATING COIL Design Size Gross Rated Heating Capacity [W] 6553.41806
68 Coil:Heating:Fuel PSZ-AC:1_SUPPHEATCOIL Design Size Nominal Capacity [W] 4151.68727
69 Controller:OutdoorAir PSZ-AC:2_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.42946
70 Controller:OutdoorAir PSZ-AC:2_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 4.89877E-002
71 Coil:Cooling:DX:SingleSpeed PSZ-AC:2 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.42946
72 Coil:Cooling:DX:SingleSpeed PSZ-AC:2 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 7109.11771
73 Coil:Cooling:DX:SingleSpeed PSZ-AC:2 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
74 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Supply Air Flow Rate [m3/s] 0.42946
75 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Supply Air Flow Rate During Heating Operation [m3/s] 0.42946
76 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Supply Air Flow Rate During Cooling Operation [m3/s] 0.42946
77 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] 0.42946
78 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Nominal Heating Capacity [W] 7109.11771
79 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Nominal Cooling Capacity [W] 7109.11771
80 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Maximum Supply Air Temperature from Supplemental Heater [C] 40.00000
81 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Supplemental Heating Coil Nominal Capacity [W] 7107.91420
82 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
83 Fan:OnOff PSZ-AC:2 FAN Design Size Maximum Flow Rate [m3/s] 0.42946
84 Coil:Heating:DX:SingleSpeed PSZ-AC:2 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.42946
85 Coil:Heating:DX:SingleSpeed PSZ-AC:2 HEATING COIL Design Size Gross Rated Heating Capacity [W] 7109.11771
86 Coil:Heating:Fuel PSZ-AC:2_SUPPHEATCOIL Design Size Nominal Capacity [W] 7107.91420
87 Controller:OutdoorAir PSZ-AC:3_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.33465
88 Controller:OutdoorAir PSZ-AC:3_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 2.90601E-002
89 Coil:Cooling:DX:SingleSpeed PSZ-AC:3 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.33465
90 Coil:Cooling:DX:SingleSpeed PSZ-AC:3 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 5539.57422
91 Coil:Cooling:DX:SingleSpeed PSZ-AC:3 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
92 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Supply Air Flow Rate [m3/s] 0.33465
93 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Supply Air Flow Rate During Heating Operation [m3/s] 0.33465
94 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Supply Air Flow Rate During Cooling Operation [m3/s] 0.33465
95 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] 0.33465
96 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Nominal Heating Capacity [W] 5539.57422
97 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Nominal Cooling Capacity [W] 5539.57422
98 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Maximum Supply Air Temperature from Supplemental Heater [C] 40.00000
99 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Supplemental Heating Coil Nominal Capacity [W] 4454.78806
100 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
101 Fan:OnOff PSZ-AC:3 FAN Design Size Maximum Flow Rate [m3/s] 0.33465
102 Coil:Heating:DX:SingleSpeed PSZ-AC:3 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.33465
103 Coil:Heating:DX:SingleSpeed PSZ-AC:3 HEATING COIL Design Size Gross Rated Heating Capacity [W] 5539.57422
104 Coil:Heating:Fuel PSZ-AC:3_SUPPHEATCOIL Design Size Nominal Capacity [W] 4454.78806
105 Controller:OutdoorAir PSZ-AC:4_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.38341
106 Controller:OutdoorAir PSZ-AC:4_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 4.89877E-002
107 Coil:Cooling:DX:SingleSpeed PSZ-AC:4 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.38341
108 Coil:Cooling:DX:SingleSpeed PSZ-AC:4 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 6346.72929
109 Coil:Cooling:DX:SingleSpeed PSZ-AC:4 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
110 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Supply Air Flow Rate [m3/s] 0.38341
111 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Supply Air Flow Rate During Heating Operation [m3/s] 0.38341
112 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Supply Air Flow Rate During Cooling Operation [m3/s] 0.38341
113 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] 0.38341
114 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Nominal Heating Capacity [W] 6346.72929
115 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Nominal Cooling Capacity [W] 6346.72929
116 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Maximum Supply Air Temperature from Supplemental Heater [C] 40.00000
117 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Supplemental Heating Coil Nominal Capacity [W] 7005.38900
118 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
119 Fan:OnOff PSZ-AC:4 FAN Design Size Maximum Flow Rate [m3/s] 0.38341
120 Coil:Heating:DX:SingleSpeed PSZ-AC:4 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.38341
121 Coil:Heating:DX:SingleSpeed PSZ-AC:4 HEATING COIL Design Size Gross Rated Heating Capacity [W] 6346.72929
122 Coil:Heating:Fuel PSZ-AC:4_SUPPHEATCOIL Design Size Nominal Capacity [W] 7005.38900
123 Controller:OutdoorAir PSZ-AC:5_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.43077
124 Controller:OutdoorAir PSZ-AC:5_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 2.90601E-002
125 Coil:Cooling:DX:SingleSpeed PSZ-AC:5 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.43077
126 Coil:Cooling:DX:SingleSpeed PSZ-AC:5 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 7130.76295
127 Coil:Cooling:DX:SingleSpeed PSZ-AC:5 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
128 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Supply Air Flow Rate [m3/s] 0.43077
129 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Supply Air Flow Rate During Heating Operation [m3/s] 0.43077
130 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Supply Air Flow Rate During Cooling Operation [m3/s] 0.43077
131 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] 0.43077
132 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Nominal Heating Capacity [W] 7130.76295
133 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Nominal Cooling Capacity [W] 7130.76295
134 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Maximum Supply Air Temperature from Supplemental Heater [C] 40.00000
135 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Supplemental Heating Coil Nominal Capacity [W] 4454.78806
136 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
137 Fan:OnOff PSZ-AC:5 FAN Design Size Maximum Flow Rate [m3/s] 0.43077
138 Coil:Heating:DX:SingleSpeed PSZ-AC:5 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.43077
139 Coil:Heating:DX:SingleSpeed PSZ-AC:5 HEATING COIL Design Size Gross Rated Heating Capacity [W] 7130.76295
140 Coil:Heating:Fuel PSZ-AC:5_SUPPHEATCOIL Design Size Nominal Capacity [W] 4454.78806
141 PlantLoop SWHSYS1 Maximum Loop Flow Rate [m3/s] 4.04800E-006
142 PlantLoop SWHSYS1 Plant Loop Volume [m3] 4.85760E-004
143 Pump:ConstantSpeed SWHSYS1 PUMP Design Flow Rate [m3/s] 4.04800E-006
144 Pump:ConstantSpeed SWHSYS1 PUMP Design Power Consumption [W] 1.72991E-008


DX Cooling Coil Standard Rating Information

Component Type Component Name Standard Rating (Net) Cooling Capacity {W} Standard Rated Net COP {W/W} EER {Btu/W-h} SEER User {Btu/W-h} SEER Standard {Btu/W-h} IEER {Btu/W-h}
1 Coil:Cooling:DX:SingleSpeed PSZ-AC:1 HP COOLING COIL 6243.2 3.29 11.22 11.74 11.10 10.96
2 Coil:Cooling:DX:SingleSpeed PSZ-AC:2 HP COOLING COIL 6772.5 3.29 11.22 11.74 11.10 10.96
3 Coil:Cooling:DX:SingleSpeed PSZ-AC:3 HP COOLING COIL 5277.3 3.29 11.22 11.74 11.10 10.96
4 Coil:Cooling:DX:SingleSpeed PSZ-AC:4 HP COOLING COIL 6046.3 3.29 11.22 11.74 11.10 10.96
5 Coil:Cooling:DX:SingleSpeed PSZ-AC:5 HP COOLING COIL 6793.2 3.29 11.22 11.74 11.10 10.96


DX Heating Coil Standard Rating Information

Component Type Component Name High Temperature Heating (net) Rating Capacity {W} Low Temperature Heating (net) Rating Capacity {W} HSPF {Btu/W-h} Region Number
1 Coil:Heating:DX:SingleSpeed PSZ-AC:1 HEATING COIL 6867.5 3824.8 7.32 4
2 Coil:Heating:DX:SingleSpeed PSZ-AC:2 HEATING COIL 7449.8 4149.1 7.33 4
3 Coil:Heating:DX:SingleSpeed PSZ-AC:3 HEATING COIL 5805.1 3233.1 7.33 4
4 Coil:Heating:DX:SingleSpeed PSZ-AC:4 HEATING COIL 6650.9 3704.2 7.32 4
5 Coil:Heating:DX:SingleSpeed PSZ-AC:5 HEATING COIL 7472.5 4161.7 7.33 4


Environment

Environment Name Environment Type Start Date End Date Start DayOfWeek Duration {#days} Source:Start DayOfWeek Use Daylight Saving Use Holidays Apply Weekend Holiday Rule Use Rain Values Use Snow Values Sky Temperature Model
1 RUNPERIOD 1 WeatherFileRunPeriod 01/01/2017 12/31/2017 Sunday 365 Use RunPeriod Specified Day No No No Yes Yes Clark and Allen


Environment:Special Days

Special Day Name Special Day Type Source Start Date Duration {#days}
1 NEW YEARS DAY Holiday InputFile 01/01 1Environment:Special Days


Environment:Daylight Saving

Daylight Saving Indicator Source Start Date End Date
1 Yes InputFile 03/12 11/05


Tabular Report

Style Unit Conversion
1 Commaandhtml commaandhtml


Warmup Convergence Information

Zone Name Environment Type/Name Average Warmup Temperature Difference {deltaC} Std Dev Warmup Temperature Difference {deltaC} Max Temperature Pass/Fail Convergence Min Temperature Pass/Fail Convergence Average Warmup Load Difference {W} Std Dev Warmup Load Difference {W} Heating Load Pass/Fail Convergence Cooling Load Pass/Fail Convergence
1 CORE_ZN RunPeriod: RUNPERIOD 1 1.6224295776E-002 9.9559010237E-003 Pass Pass 0.0000000000 0.0000000000 Pass Pass
2 PERIMETER_ZN_1 RunPeriod: RUNPERIOD 1 8.9371350474E-002 7.5023422752E-002 Pass Pass 0.0000000000 0.0000000000 Pass Pass
3 PERIMETER_ZN_2 RunPeriod: RUNPERIOD 1 0.1878991523 0.2545106126 Pass Pass 0.6609172595 1.7228944394 Pass Pass
4 PERIMETER_ZN_3 RunPeriod: RUNPERIOD 1 0.3587177223 0.3564701708 Pass Pass 0.3857133893 0.6634841391 Pass Pass
5 PERIMETER_ZN_4 RunPeriod: RUNPERIOD 1 0.2135907668 0.2540320666 Pass Pass 0.5359208413 1.2445493070 Pass Pass
6 ATTIC RunPeriod: RUNPERIOD 1 0.4305400152 0.5143527124 Pass Pass 0.0000000000 0.0000000000 Pass Pass



Table of Contents

Report: Annual Heat Emissions Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

Heat Emission by Components

Envelope Convection Zone Exfiltration Zone Exhaust Air HVAC Relief Air HVAC Reject Heat Total
Heat Emissions [GJ] 1084.58 40.67 0.00 106.37 69.15 1300.77



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB -17.90 0.00 -17.90 Wetbulb [C] 2.50 180.00
DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 33.90 14.80 15.00 Wetbulb [C] 3.60 30.00


Monthly Precipitation Summary

Monthly Total Precipitation from .epw [mm] Monthly Total Hours of Rain from .epw Monthly Total Precipitation in Site:Precipitation [mm] Monthly Total Roof Irrigation Depth [mm] Monthly Total Rain Collection Volume [m3]
Jan 11.00 10      
Feb 15.00 16      
Mar 88.00 32      
Apr 159.00 54      
May 30.00 24      
Jun 11.00 4      
Jul 167.00 26      
Aug 33.00 24      
Sep 8.00 8      
Oct 13.00 10      
Nov 12.00 22      
Dec 11.00 18      


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Net Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
PERIMETER_ZN_1_WALL_SOUTH NONRES_EXT_WALL_GRD 0.30 0.977 1.144 84.45 63.82 180.00 90.00 S
PERIMETER_ZN_1_FLOOR PERIMETER_ZN_1_FLOOR_FFACTOR 1.00 0.228 0.237 113.45 113.45 135.00 180.00  
PERIMETER_ZN_2_WALL_EAST NONRES_EXT_WALL_GRD 0.30 0.977 1.144 56.30 45.15 90.00 90.00 E
PERIMETER_ZN_2_FLOOR PERIMETER_ZN_2_FLOOR_FFACTOR 1.00 0.256 0.267 67.30 67.30 270.00 180.00  
PERIMETER_ZN_3_WALL_NORTH NONRES_EXT_WALL_GRD 0.30 0.977 1.144 84.45 63.83 0.00 90.00 N
PERIMETER_ZN_3_FLOOR PERIMETER_ZN_3_FLOOR_FFACTOR 1.00 0.228 0.237 113.45 113.45 180.00 180.00  
PERIMETER_ZN_4_WALL_WEST NONRES_EXT_WALL_GRD 0.30 0.977 1.144 56.30 45.15 270.00 90.00 W
PERIMETER_ZN_4_FLOOR PERIMETER_ZN_4_FLOOR_FFACTOR 1.00 0.256 0.267 67.30 67.30 90.00 180.00  
ATTIC_SOFFIT_WEST EXT_SOFFIT_FLOOR 0.30 3.082 7.547 11.44 11.44 270.00 180.00  
ATTIC_SOFFIT_SOUTH EXT_SOFFIT_FLOOR 0.30 3.082 7.547 16.97 16.97 225.00 180.00  
ATTIC_SOFFIT_EAST EXT_SOFFIT_FLOOR 0.30 3.082 7.547 11.44 11.44 45.00 180.00  
ATTIC_SOFFIT_NORTH EXT_SOFFIT_FLOOR 0.30 3.082 7.547 16.97 16.97 315.00 180.00  
ATTIC_ROOF_NORTH ATTICROOFDECK 0.30 2.858 4.706 197.51 197.51 0.00 18.45  
ATTIC_ROOF_WEST ATTICROOFDECK 0.30 2.858 4.706 101.87 101.87 270.00 18.45  
ATTIC_ROOF_EAST ATTICROOFDECK 0.30 2.858 4.706 101.87 101.87 90.00 18.45  
ATTIC_ROOF_SOUTH ATTICROOFDECK 0.30 2.858 4.706 197.51 197.51 180.00 18.45  


Opaque Interior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Net Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
CORE_ZN_WALL_SOUTH INT_WALL 0.30 2.511 6.299 53.95 53.95 180.00 90.00 S
CORE_ZN_WALL_EAST INT_WALL 0.30 2.511 6.299 25.80 25.80 90.00 90.00 E
CORE_ZN_WALL_NORTH INT_WALL 0.30 2.511 6.299 53.95 53.95 0.00 90.00 N
CORE_ZN_WALL_WEST INT_WALL 0.30 2.511 6.299 25.80 25.80 270.00 90.00 W
CORE_ZN_FLOOR CORE_ZN_FLOOR_FFACTOR 1.00 0.006 0.006 149.66 149.66 270.00 180.00  
CORE_ZN_CEILING NONRES_ROOF 0.30 0.151 0.158 149.66 149.66 270.00 0.00  
PERIMETER_ZN_1_WALL_WEST INT_WALL 0.30 2.511 6.299 21.57 21.57 315.00 90.00 N
PERIMETER_ZN_1_WALL_EAST INT_WALL 0.30 2.511 6.299 21.57 21.57 45.00 90.00 E
PERIMETER_ZN_1_WALL_NORTH INT_WALL 0.30 2.511 6.299 53.95 53.95 0.00 90.00 N
PERIMETER_ZN_1_CEILING NONRES_ROOF 0.30 0.151 0.158 113.45 113.45 45.00 0.00  
PERIMETER_ZN_2_WALL_NORTH INT_WALL 0.30 2.511 6.299 21.57 21.57 315.00 90.00 N
PERIMETER_ZN_2_WALL_SOUTH INT_WALL 0.30 2.511 6.299 21.57 21.57 225.00 90.00 W
PERIMETER_ZN_2_WALL_WEST INT_WALL 0.30 2.511 6.299 25.80 25.80 270.00 90.00 W
PERIMETER_ZN_2_CEILING NONRES_ROOF 0.30 0.151 0.158 67.30 67.30 270.00 0.00  
PERIMETER_ZN_3_WALL_SOUTH INT_WALL 0.30 2.511 6.299 53.95 53.95 180.00 90.00 S
PERIMETER_ZN_3_WALL_WEST INT_WALL 0.30 2.511 6.299 21.57 21.57 225.00 90.00 W
PERIMETER_ZN_3_WALL_EAST INT_WALL 0.30 2.511 6.299 21.57 21.57 135.00 90.00 S
PERIMETER_ZN_3_CEILING NONRES_ROOF 0.30 0.151 0.158 113.45 113.45 180.00 0.00  
PERIMETER_ZN_4_WALL_SOUTH INT_WALL 0.30 2.511 6.299 21.57 21.57 135.00 90.00 S
PERIMETER_ZN_4_WALL_NORTH INT_WALL 0.30 2.511 6.299 21.57 21.57 45.00 90.00 E
PERIMETER_ZN_4_WALL_EAST INT_WALL 0.30 2.511 6.299 25.80 25.80 90.00 90.00 E
PERIMETER_ZN_4_CEILING NONRES_ROOF 0.30 0.151 0.158 67.30 67.30 90.00 0.00  
ATTIC_FLOOR_PERIMETER_SOUTH NONRES_ROOF_FLOOR 0.30 0.151 0.158 113.45 113.45 180.00 180.00  
ATTIC_FLOOR_PERIMETER_WEST NONRES_ROOF_FLOOR 0.30 0.151 0.158 67.30 67.30 315.00 180.00  
ATTIC_FLOOR_PERIMETER_EAST NONRES_ROOF_FLOOR 0.30 0.151 0.158 67.30 67.30 135.00 180.00  
ATTIC_FLOOR_CORE NONRES_ROOF_FLOOR 0.30 0.151 0.158 149.66 149.66 270.00 180.00  
ATTIC_FLOOR_PERIMETER_NORTH NONRES_ROOF_FLOOR 0.30 0.151 0.158 113.45 113.45 315.00 180.00  
CORE_ZN_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 299.31   0.00 90.00 N
PERIMETER_ZN_1_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 226.90   0.00 90.00 N
PERIMETER_ZN_2_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 134.60   0.00 90.00 N
PERIMETER_ZN_3_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 226.90   0.00 90.00 N
PERIMETER_ZN_4_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 134.60   0.00 90.00 N


Exterior Fenestration

Construction Frame and Divider Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] NFRC Product Type Assembly U-Factor [W/m2-K] Assembly SHGC Assembly Visible Transmittance Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 WINDOW_U_0.3822_SHGC_SOUTH_0.4   2.79 0.00 0.00 2.79 2.79 2.171 0.401 0.402             No PERIMETER_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 WINDOW_U_0.3822_SHGC_SOUTH_0.4   2.79 0.00 0.00 2.79 2.79 2.171 0.401 0.402             No PERIMETER_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 WINDOW_U_0.3822_SHGC_SOUTH_0.4   2.79 0.00 0.00 2.79 2.79 2.171 0.401 0.402             No PERIMETER_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 WINDOW_U_0.3822_SHGC_SOUTH_0.4   2.79 0.00 0.00 2.79 2.79 2.171 0.401 0.402             No PERIMETER_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 WINDOW_U_0.3822_SHGC_SOUTH_0.4   2.79 0.00 0.00 2.79 2.79 2.171 0.401 0.402             No PERIMETER_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 WINDOW_U_0.3822_SHGC_SOUTH_0.4   2.79 0.00 0.00 2.79 2.79 2.171 0.401 0.402             No PERIMETER_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_ZN_1_WALL_SOUTH_DOOR WINDOW_U_0.3822_SHGC_SOUTH_0.4   3.91 0.00 0.00 3.91 3.91 2.171 0.401 0.402             No PERIMETER_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_ZN_2_WALL_EAST_WINDOW_4 WINDOW_U_0.3822_SHGC_EAST_0.4   2.79 0.00 0.00 2.79 2.79 2.171 0.401 0.402             No PERIMETER_ZN_2_WALL_EAST 90.00 90.00 E
PERIMETER_ZN_2_WALL_EAST_WINDOW_3 WINDOW_U_0.3822_SHGC_EAST_0.4   2.79 0.00 0.00 2.79 2.79 2.171 0.401 0.402             No PERIMETER_ZN_2_WALL_EAST 90.00 90.00 E
PERIMETER_ZN_2_WALL_EAST_WINDOW_2 WINDOW_U_0.3822_SHGC_EAST_0.4   2.79 0.00 0.00 2.79 2.79 2.171 0.401 0.402             No PERIMETER_ZN_2_WALL_EAST 90.00 90.00 E
PERIMETER_ZN_2_WALL_EAST_WINDOW_1 WINDOW_U_0.3822_SHGC_EAST_0.4   2.79 0.00 0.00 2.79 2.79 2.171 0.401 0.402             No PERIMETER_ZN_2_WALL_EAST 90.00 90.00 E
PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 WINDOW_U_0.3822_SHGC_NORTH_0.4   2.79 0.00 0.00 2.79 2.79 2.171 0.401 0.402             No PERIMETER_ZN_3_WALL_NORTH 0.00 90.00 N
PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 WINDOW_U_0.3822_SHGC_NORTH_0.4   2.79 0.00 0.00 2.79 2.79 2.171 0.401 0.402             No PERIMETER_ZN_3_WALL_NORTH 0.00 90.00 N
PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 WINDOW_U_0.3822_SHGC_NORTH_0.4   2.79 0.00 0.00 2.79 2.79 2.171 0.401 0.402             No PERIMETER_ZN_3_WALL_NORTH 0.00 90.00 N
PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 WINDOW_U_0.3822_SHGC_NORTH_0.4   2.79 0.00 0.00 2.79 2.79 2.171 0.401 0.402             No PERIMETER_ZN_3_WALL_NORTH 0.00 90.00 N
PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 WINDOW_U_0.3822_SHGC_NORTH_0.4   2.79 0.00 0.00 2.79 2.79 2.171 0.401 0.402             No PERIMETER_ZN_3_WALL_NORTH 0.00 90.00 N
PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 WINDOW_U_0.3822_SHGC_NORTH_0.4   2.79 0.00 0.00 2.79 2.79 2.171 0.401 0.402             No PERIMETER_ZN_3_WALL_NORTH 0.00 90.00 N
PERIMETER_ZN_4_WALL_WEST_WINDOW_4 WINDOW_U_0.3822_SHGC_WEST_0.4   2.79 0.00 0.00 2.79 2.79 2.171 0.401 0.402             No PERIMETER_ZN_4_WALL_WEST 270.00 90.00 W
PERIMETER_ZN_4_WALL_WEST_WINDOW_3 WINDOW_U_0.3822_SHGC_WEST_0.4   2.79 0.00 0.00 2.79 2.79 2.171 0.401 0.402             No PERIMETER_ZN_4_WALL_WEST 270.00 90.00 W
PERIMETER_ZN_4_WALL_WEST_WINDOW_2 WINDOW_U_0.3822_SHGC_WEST_0.4   2.79 0.00 0.00 2.79 2.79 2.171 0.401 0.402             No PERIMETER_ZN_4_WALL_WEST 270.00 90.00 W
PERIMETER_ZN_4_WALL_WEST_WINDOW_1 WINDOW_U_0.3822_SHGC_WEST_0.4   2.79 0.00 0.00 2.79 2.79 2.171 0.401 0.402             No PERIMETER_ZN_4_WALL_WEST 270.00 90.00 W
Total or Average             59.65 2.171 0.401 0.402                      
North Total or Average             16.72 2.171 0.401 0.402                      
Non-North Total or Average             42.93 2.171 0.401 0.402                      


Exterior Fenestration Shaded State

Frame and Divider Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance NFRC Product Type Assembly U-Factor [W/m2-K] Assembly SHGC Assembly Visible Transmittance
None                


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance
Total or Average     0.00 - - -


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
PERIMETER_ZN_3_WALL_NORTH_DOOR1 SWINGING DOOR_CON 1.598 2.101 1.95 PERIMETER_ZN_3_WALL_NORTH
PERIMETER_ZN_3_WALL_NORTH_DOOR2 SWINGING DOOR_CON 1.598 2.101 1.95 PERIMETER_ZN_3_WALL_NORTH


Interior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 0.98 0.97 0.97 0.00 0.09 0.00 1.00 1.00 1.00
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 0.98 0.97 0.97 0.00 0.09 0.00 1.00 1.00 1.00
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 0.98 0.97 0.97 0.00 0.09 0.00 1.00 1.00 1.00
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 0.98 0.97 0.97 0.00 0.09 0.00 1.00 1.00 1.00
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 0.98 0.97 0.97 0.00 0.09 0.00 1.00 1.00 1.00
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 0.98 0.97 0.97 0.00 0.09 0.00 1.00 1.00 1.00
PERIMETER_ZN_1_WALL_SOUTH_DOOR 1.00 1.00 1.00 0.00 0.49 0.00 1.00 1.00 1.00
PERIMETER_ZN_2_WALL_EAST_WINDOW_4 1.00 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
PERIMETER_ZN_2_WALL_EAST_WINDOW_3 1.00 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
PERIMETER_ZN_2_WALL_EAST_WINDOW_2 1.00 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
PERIMETER_ZN_2_WALL_EAST_WINDOW_1 1.00 0.00 0.00 1.00 0.00 0.00 1.00 0.42 0.00
PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_4_WALL_WEST_WINDOW_4 0.00 0.00 1.00 0.00 0.00 0.89 0.00 0.00 1.00
PERIMETER_ZN_4_WALL_WEST_WINDOW_3 0.00 0.00 1.00 0.00 0.00 0.89 0.00 0.00 1.00
PERIMETER_ZN_4_WALL_WEST_WINDOW_2 0.00 0.00 1.00 0.00 0.00 0.89 0.00 0.00 1.00
PERIMETER_ZN_4_WALL_WEST_WINDOW_1 0.00 0.00 1.00 0.00 0.00 0.89 0.00 0.00 1.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

Interior Lighting

Zone Name Space Name Space Type Lighting Power Density [W/m2] Space Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
CORE_ZN_LIGHTS CORE_ZN CORE_ZN GENERAL 9.0375 149.66 1352.53 LightsWired LTG_SCH_OFFICE 54.48 168.00 53.53 0.0000 Y 13.59
PERIMETER_ZN_1_LIGHTS PERIMETER_ZN_1 PERIMETER_ZN_1 GENERAL 9.0375 113.45 1025.31 LightsWired LTG_SCH_OFFICE 54.48 168.00 45.36 0.0000 Y 8.73
PERIMETER_ZN_2_LIGHTS PERIMETER_ZN_2 PERIMETER_ZN_2 GENERAL 9.0375 67.30 608.22 LightsWired LTG_SCH_OFFICE 54.48 168.00 46.63 0.0000 Y 5.32
PERIMETER_ZN_3_LIGHTS PERIMETER_ZN_3 PERIMETER_ZN_3 GENERAL 9.0375 113.45 1025.31 LightsWired LTG_SCH_OFFICE 54.48 168.00 47.56 0.0000 Y 9.15
PERIMETER_ZN_4_LIGHTS PERIMETER_ZN_4 PERIMETER_ZN_4 GENERAL 9.0375 67.30 608.22 LightsWired LTG_SCH_OFFICE 54.48 168.00 46.60 0.0000 Y 5.32
Interior Lighting Total       9.0375 511.16 4619.59               42.12


Daylighting

Zone Control Name Daylighting Method Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
PERIMETER_ZN_1_DAYLREFPT1 PERIMETER_ZN_1 PERIMETER_ZN_1_DAYLCTRL SplitFlux Continuous/Off 0.24 1025.31 245.97
PERIMETER_ZN_1_DAYLREFPT2 PERIMETER_ZN_1 PERIMETER_ZN_1_DAYLCTRL SplitFlux Continuous/Off 0.00 1025.31 0.00
PERIMETER_ZN_2_DAYLREFPT1 PERIMETER_ZN_2 PERIMETER_ZN_2_DAYLCTRL SplitFlux Continuous/Off 0.24 608.22 145.91
PERIMETER_ZN_2_DAYLREFPT2 PERIMETER_ZN_2 PERIMETER_ZN_2_DAYLCTRL SplitFlux Continuous/Off 0.00 608.22 0.00
PERIMETER_ZN_3_DAYLREFPT1 PERIMETER_ZN_3 PERIMETER_ZN_3_DAYLCTRL SplitFlux Continuous/Off 0.24 1025.31 245.97
PERIMETER_ZN_3_DAYLREFPT2 PERIMETER_ZN_3 PERIMETER_ZN_3_DAYLCTRL SplitFlux Continuous/Off 0.00 1025.31 0.00
PERIMETER_ZN_4_DAYLREFPT1 PERIMETER_ZN_4 PERIMETER_ZN_4_DAYLCTRL SplitFlux Continuous/Off 0.24 608.22 145.91
PERIMETER_ZN_4_DAYLREFPT2 PERIMETER_ZN_4 PERIMETER_ZN_4_DAYLCTRL SplitFlux Continuous/Off 0.00 608.22 0.00


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
EXTERIOR_LIGHTS_A 66.70 AstronomicalClock -   42.26 42.26 0.53
EXTERIOR_LIGHTS_B 1507.70 AstronomicalClock -   83.67 71.25 20.16
Exterior Lighting Total 1574.40           20.69



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

Central Plant

Type Reference Capacity [W] Reference Efficiency [W/W] Rated Capacity [W] Rated Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
None              


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
PSZ-AC:1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   6553.42 5247.03 1306.39 0.80 4.12    
PSZ-AC:2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   7109.12 5691.95 1417.17 0.80 4.12    
PSZ-AC:3 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   5539.57 4435.29 1104.28 0.80 4.12    
PSZ-AC:4 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   6346.73 5081.54 1265.19 0.80 4.12    
PSZ-AC:5 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   7130.76 5709.28 1421.48 0.80 4.12    
Nominal values are gross at rated conditions, i.e., the supply air fan heat and electric power NOT accounted for.

DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER User [Btu/W-h] SEER Standard [Btu/W-h] IEER [Btu/W-h]
PSZ-AC:1 HP COOLING COIL   6243.2 3.29 11.22 11.74 11.10 10.96
PSZ-AC:2 HP COOLING COIL   6772.5 3.29 11.22 11.74 11.10 10.96
PSZ-AC:3 HP COOLING COIL   5277.3 3.29 11.22 11.74 11.10 10.96
PSZ-AC:4 HP COOLING COIL   6046.3 3.29 11.22 11.74 11.10 10.96
PSZ-AC:5 HP COOLING COIL   6793.2 3.29 11.22 11.74 11.10 10.96
ANSI/AHRI ratings account for supply air fan heat and electric power. SEER User is calculated using user-input PLF curve and cooling coefficient of degradation whereas SEER Standard is calculated using AHRI Std 210/240-2008 default PLF curve and cooling coefficient of degradation.

DX Cooling Coil ASHRAE 127 Standard Ratings Report

DX Cooling Coil Type Rated Net Cooling Capacity Test A [W] Rated Electric Power Test A [W] Rated Net Cooling Capacity Test B [W] Rated Electric Power Test B [W] Rated Net Cooling Capacity Test C [W] Rated Electric Power Test C [W] Rated Net Cooling Capacity Test D [W] Rated Electric Power Test D [W]
PSZ-AC:1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
PSZ-AC:2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
PSZ-AC:3 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
PSZ-AC:4 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
PSZ-AC:5 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                


DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
PSZ-AC:1 HEATING COIL Coil:Heating:DX:SingleSpeed 6867.5 3824.8 7.32 4
PSZ-AC:2 HEATING COIL Coil:Heating:DX:SingleSpeed 7449.8 4149.1 7.33 4
PSZ-AC:3 HEATING COIL Coil:Heating:DX:SingleSpeed 5805.1 3233.1 7.33 4
PSZ-AC:4 HEATING COIL Coil:Heating:DX:SingleSpeed 6650.9 3704.2 7.32 4
PSZ-AC:5 HEATING COIL Coil:Heating:DX:SingleSpeed 7472.5 4161.7 7.33 4
ANSI/AHRI ratings account for supply air fan heat and electric power.

Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
PSZ-AC:1 HEATING COIL Coil:Heating:DX:SingleSpeed   6553.42 3.36
PSZ-AC:1_SUPPHEATCOIL Coil:Heating:Fuel   4151.69 0.80
PSZ-AC:2 HEATING COIL Coil:Heating:DX:SingleSpeed   7109.12 3.36
PSZ-AC:2_SUPPHEATCOIL Coil:Heating:Fuel   7107.91 0.80
PSZ-AC:3 HEATING COIL Coil:Heating:DX:SingleSpeed   5539.57 3.36
PSZ-AC:3_SUPPHEATCOIL Coil:Heating:Fuel   4454.79 0.80
PSZ-AC:4 HEATING COIL Coil:Heating:DX:SingleSpeed   6346.73 3.36
PSZ-AC:4_SUPPHEATCOIL Coil:Heating:Fuel   7005.39 0.80
PSZ-AC:5 HEATING COIL Coil:Heating:DX:SingleSpeed   7130.76 3.36
PSZ-AC:5_SUPPHEATCOIL Coil:Heating:Fuel   4454.79 0.80
Nominal values are gross at rated conditions, i.e., the supply air fan heat and electric power NOT accounted for.

Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electricity Rate [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction Fan Energy Index End Use Subcategory Design Day Name for Fan Sizing Peak Date/Time for Fan Sizing Peak
PSZ-AC:1 FAN Fan:OnOff 0.56 622.50 0.40 443.44 1120.11 1.00 1.72 General DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00
PSZ-AC:2 FAN Fan:OnOff 0.56 622.50 0.43 481.04 1120.11 1.00 1.68 General DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00
PSZ-AC:3 FAN Fan:OnOff 0.56 622.50 0.33 374.84 1120.11 1.00 1.82 General DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00
PSZ-AC:4 FAN Fan:OnOff 0.56 622.50 0.38 429.46 1120.11 1.00 1.74 General DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00
PSZ-AC:5 FAN Fan:OnOff 0.56 622.50 0.43 482.51 1120.11 1.00 1.68 General DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:50:00


Pumps

Type Control Head [pa] Water Flow [m3/s] Electricity Rate [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W] End Use Subcategory
SWHSYS1 PUMP Pump:ConstantSpeed Intermittent 0.00 0.000004 0.00 0.00 0.30 General


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
SWHSYS1 WATER HEATER WaterHeater:Mixed 0.15 11722.84 1.00 0.98 0.46



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

Zone Sensible Cooling

Calculated Design Load [W] User Design Load [W] User Design Load per Area [W/m2] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak {TIMESTAMP} Thermostat Setpoint Temperature at Peak Load [C] Indoor Temperature at Peak Load [C] Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Outdoor Temperature at Peak Load [C] Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Minimum Outdoor Air Flow Rate [m3/s] Heat Gain Rate from DOAS [W]
CORE_ZN 3649.76 4379.72 29.26 0.330 0.396 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 16:10:00 23.89 23.89 0.00899 32.81 0.00547 0.065 0.00
PERIMETER_ZN_1 3959.20 4751.05 41.88 0.358 0.429 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 23.89 23.89 0.00876 33.90 0.00548 0.049 0.00
PERIMETER_ZN_2 3085.23 3702.27 55.01 0.279 0.335 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 09:50:00 23.89 23.89 0.00869 27.86 0.00547 0.029 0.00
PERIMETER_ZN_3 3534.69 4241.62 37.39 0.320 0.383 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:50:00 23.89 23.89 0.00879 33.16 0.00547 0.049 0.00
PERIMETER_ZN_4 3971.41 4765.69 70.81 0.359 0.431 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:50:00 23.89 23.89 0.00865 30.59 0.00547 0.029 0.00
The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.

Zone Sensible Heating

Calculated Design Load [W] User Design Load [W] User Design Load per Area [W/m2] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak {TIMESTAMP} Thermostat Setpoint Temperature at Peak Load [C] Indoor Temperature at Peak Load [C] Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Outdoor Temperature at Peak Load [C] Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Minimum Outdoor Air Flow Rate [m3/s] Heat Gain Rate from DOAS [W]
CORE_ZN 1417.05 1700.46 11.36 0.075 0.090 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 21.11 21.11 0.00800 -17.90 0.00096 0.065 0.00
PERIMETER_ZN_1 4423.59 5308.30 46.79 0.235 0.282 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 21.11 21.11 0.00778 -17.90 0.00096 0.049 0.00
PERIMETER_ZN_2 2825.63 3390.76 50.38 0.150 0.180 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 21.11 21.11 0.00777 -17.90 0.00096 0.029 0.00
PERIMETER_ZN_3 4336.89 5204.26 45.87 0.230 0.276 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 21.11 21.11 0.00778 -17.90 0.00096 0.049 0.00
PERIMETER_ZN_4 2825.63 3390.76 50.38 0.150 0.180 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 21.11 21.11 0.00777 -17.90 0.00096 0.029 0.00
The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.

System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s] Adjusted cooling [m3/s] Adjusted heating [m3/s] Adjusted main [m3/s] Calculated Heating Air Flow Ratio [] User Heating Air Flow Ratio []
PSZ-AC:1 0.40 0.40 0.09 0.09 0.3959 0.3959 0.3959 1.0000 1.0000
PSZ-AC:2 0.43 0.43 0.28 0.28 0.4295 0.4295 0.4295 1.0000 1.0000
PSZ-AC:3 0.33 0.33 0.18 0.18 0.3346 0.3346 0.3346 1.0000 1.0000
PSZ-AC:4 0.38 0.38 0.28 0.28 0.3834 0.3834 0.3834 1.0000 1.0000
PSZ-AC:5 0.43 0.43 0.18 0.18 0.4308 0.4308 0.4308 1.0000 1.0000


Plant Loop Coincident Design Fluid Flow Rate Adjustments

Previous Design Volume Flow Rate [m3/s] Algorithm Volume Flow Rate [m3/s] Coincident Design Volume Flow Rate [m3/s] Coincident Size Adjusted Peak Sizing Period Name Peak Day into Period {TIMESTAMP}[day] Peak Hour Of Day {TIMESTAMP}[hr] Peak Step Start Minute {TIMESTAMP}[min]
None                


Coil Sizing Summary

Coil Type HVAC Type HVAC Name Coil Final Gross Total Capacity [W] Coil Final Gross Sensible Capacity [W] Coil Final Reference Air Volume Flow Rate [m3/s] Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] Coil U-value Times Area Value [W/K] Design Day Name at Sensible Ideal Loads Peak Date/Time at Sensible Ideal Loads Peak Design Day Name at Air Flow Ideal Loads Peak Date/Time at Air Flow Ideal Loads Peak Coil Total Capacity at Ideal Loads Peak [W] Coil Sensible Capacity at Ideal Loads Peak [W] Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] Coil Entering Air Drybulb at Ideal Loads Peak [C] Coil Entering Air Wetbulb at Ideal Loads Peak [C] Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Coil Leaving Air Drybulb at Ideal Loads Peak [C] Coil Leaving Air Wetbulb at Ideal Loads Peak [C] Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Outdoor Air Drybulb at Ideal Loads Peak [C] Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Outdoor Air Wetbulb at Ideal Loads Peak [C] Outdoor Air Flow Percentage at Ideal Loads Peak [%] Zone Air Drybulb at Ideal Loads Peak [C] Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Zone Air Relative Humidity at Ideal Loads Peak [%] Zone Sensible Heat Gain at Ideal Loads Peak [W] Zone Latent Heat Gain at Ideal Loads Peak [W] Coil Total Capacity at Rating Conditions [W] Coil Sensible Capacity at Rating Conditions [W]
PSZ-AC:1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC PSZ-AC:1 6553.418 5247.029 0.395892 -999.0 -999.000 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 16:10:00 5946.91 5946.91 0.395892 26.47 15.00 0.00841636 12.80 10.14 0.00841636 32.81 0.00547359 14.72 16.3232 23.89 0.00899416 39.5319 3625.00 0.00 6552.29 4731.67
PSZ-AC:1 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoopHVAC PSZ-AC:1 6553.418 6553.418 0.395892 -999.0 -999.000 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 6553.42 6553.42 0.395892 14.74 9.39 0.00685007 40.00 18.76 0.00800000 -17.90 0.00095524 -17.90 16.3232 21.11 0.00800000 41.6969 1417.05 0.00 6562.03 6562.03
PSZ-AC:1_SUPPHEATCOIL Coil:Heating:Fuel AirLoopHVAC PSZ-AC:1 4151.687 4151.687 -999.0 -999.0 -999.000 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 4151.69 4151.69 0.395892 14.74 9.39 0.00685007 40.00 18.76 0.00800000 -17.90 0.00095524 -17.90 16.3232 21.11 0.00800000 41.6969 1417.05 0.00 -999.00 -999.00
PSZ-AC:2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC PSZ-AC:2 7109.118 5691.952 0.429462 -999.0 -999.000 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 6357.62 6357.62 0.429462 26.15 14.87 0.00838640 12.80 10.11 0.00838640 33.90 0.00547527 15.07 11.4068 23.89 0.00876122 38.5217 3959.20 0.00 7107.90 5132.90
PSZ-AC:2 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoopHVAC PSZ-AC:2 7109.118 7109.118 0.429462 -999.0 -999.000 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 7109.12 7109.12 0.429462 16.66 10.30 0.00700467 40.00 18.76 0.00800000 -17.90 0.00095524 -17.90 11.4068 21.11 0.00778356 40.5847 4423.59 0.00 7118.46 7118.46
PSZ-AC:2_SUPPHEATCOIL Coil:Heating:Fuel AirLoopHVAC PSZ-AC:2 7107.914 7107.914 -999.0 -999.0 -999.000 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 7107.91 7107.91 0.429462 16.66 10.30 0.00700467 40.00 18.76 0.00800000 -17.90 0.00095524 -17.90 11.4068 21.11 0.00778356 40.5847 4423.59 0.00 -999.00 -999.00
PSZ-AC:3 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC PSZ-AC:3 5539.574 4435.289 0.334646 -999.0 -999.000 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 10:10:00 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 09:50:00 5191.14 5191.14 0.334646 25.36 14.63 0.00841122 12.80 10.13 0.00841122 27.86 0.00546603 13.03 8.6839 23.89 0.00869258 38.2233 3077.15 0.00 5538.62 3999.66
PSZ-AC:3 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoopHVAC PSZ-AC:3 5539.574 5539.574 0.334646 -999.0 -999.000 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 5539.57 5539.57 0.334646 17.72 10.87 0.00718224 40.00 18.76 0.00800000 -17.90 0.00095524 -17.90 8.6839 21.11 0.00777441 40.5377 2825.63 0.00 5546.85 5546.85
PSZ-AC:3_SUPPHEATCOIL Coil:Heating:Fuel AirLoopHVAC PSZ-AC:3 4454.788 4454.788 -999.0 -999.0 -999.000 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 4454.79 4454.79 0.334646 17.72 10.87 0.00718224 40.00 18.76 0.00800000 -17.90 0.00095524 -17.90 8.6839 21.11 0.00777441 40.5377 2825.63 0.00 -999.00 -999.00
PSZ-AC:4 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC PSZ-AC:4 6346.729 5081.542 0.383406 -999.0 -999.000 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:30:00 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:50:00 5719.67 5719.67 0.383406 26.20 14.87 0.00836795 12.80 10.09 0.00836795 33.16 0.00547412 14.83 12.7770 23.89 0.00879249 38.6569 3528.08 0.00 6345.64 4582.44
PSZ-AC:4 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoopHVAC PSZ-AC:4 6346.729 6346.729 0.383406 -999.0 -999.000 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 6346.73 6346.73 0.383406 16.13 10.00 0.00690745 40.00 18.76 0.00800000 -17.90 0.00095524 -17.90 12.7770 21.11 0.00777937 40.5631 4336.89 0.00 6355.07 6355.07
PSZ-AC:4_SUPPHEATCOIL Coil:Heating:Fuel AirLoopHVAC PSZ-AC:4 7005.389 7005.389 -999.0 -999.0 -999.000 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 7005.39 7005.39 0.383406 16.13 10.00 0.00690745 40.00 18.76 0.00800000 -17.90 0.00095524 -17.90 12.7770 21.11 0.00777937 40.5631 4336.89 0.00 -999.00 -999.00
PSZ-AC:5 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC PSZ-AC:5 7130.763 5709.283 0.430769 -999.0 -999.000 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:50:00 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:50:00 6550.42 6550.42 0.430769 25.46 14.68 0.00843518 12.80 10.15 0.00843518 30.59 0.00547019 13.98 6.7461 23.89 0.00864967 38.0372 3971.41 0.00 7129.54 5148.53
PSZ-AC:5 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoopHVAC PSZ-AC:5 7130.763 7130.763 0.430769 -999.0 -999.000 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 7130.76 7130.76 0.430769 18.48 11.28 0.00731438 40.00 18.76 0.00800000 -17.90 0.00095524 -17.90 6.7461 21.11 0.00777441 40.5377 2825.63 0.00 7140.13 7140.13
PSZ-AC:5_SUPPHEATCOIL Coil:Heating:Fuel AirLoopHVAC PSZ-AC:5 4454.788 4454.788 -999.0 -999.0 -999.000 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 4454.79 4454.79 0.430769 18.48 11.28 0.00731438 40.00 18.76 0.00800000 -17.90 0.00095524 -17.90 6.7461 21.11 0.00777441 40.5377 2825.63 0.00 -999.00 -999.00



Table of Contents

Report: Coil Sizing Details

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

Coils

Coil Type Coil Location HVAC Type HVAC Name Zone Name(s) System Sizing Method Concurrence System Sizing Method Capacity System Sizing Method Air Flow Autosized Coil Capacity? Autosized Coil Airflow? Autosized Coil Water Flow? OA Pretreated prior to coil inlet? Coil Final Gross Total Capacity [W] Coil Final Gross Sensible Capacity [W] Coil Final Reference Air Volume Flow Rate [m3/s] Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] Coil U-value Times Area Value [W/K] Terminal Unit Reheat Coil Multiplier DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio Moist Air Heat Capacity [J/kg-K] Dry Air Heat Capacity [J/kg-K] Standard Air Density Adjusted for Elevation [kg/m3] Supply Fan Name for Coil Supply Fan Type for Coil Supply Fan Maximum Air Volume Flow Rate [m3/s] Supply Fan Maximum Air Mass Flow Rate [kg/s] Plant Name for Coil Plant Fluid Specific Heat Capacity [J/kg-K] Plant Fluid Density [kg/m3] Plant Maximum Fluid Mass Flow Rate [kg/s] Plant Design Fluid Return Temperature [C] Plant Design Fluid Supply Temperature [C] Plant Design Fluid Temperature Difference [deltaC] Plant Design Capacity [W] Coil Capacity Percentage of Plant Design Capacity [%] Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] Design Day Name at Sensible Ideal Loads Peak Date/Time at Sensible Ideal Loads Peak Design Day Name at Total Ideal Loads Peak Date/Time at Total Ideal Loads Peak Design Day Name at Air Flow Ideal Loads Peak Date/Time at Air Flow Ideal Loads Peak Peak Load Type to Size On Coil Total Capacity at Ideal Loads Peak [W] Coil Sensible Capacity at Ideal Loads Peak [W] Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] Coil Entering Air Drybulb at Ideal Loads Peak [C] Coil Entering Air Wetbulb at Ideal Loads Peak [C] Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] Coil Leaving Air Drybulb at Ideal Loads Peak [C] Coil Leaving Air Wetbulb at Ideal Loads Peak [C] Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] Supply Fan Air Heat Gain at Ideal Loads Peak [W] Coil and Fan Net Total Capacity at Ideal Loads Peak [W] Outdoor Air Drybulb at Ideal Loads Peak [C] Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Outdoor Air Wetbulb at Ideal Loads Peak [C] Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] Outdoor Air Flow Percentage at Ideal Loads Peak [%] System Return Air Drybulb at Ideal Loads Peak [C] System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Zone Air Drybulb at Ideal Loads Peak [C] Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Zone Air Relative Humidity at Ideal Loads Peak [%] Zone Sensible Heat Gain at Ideal Loads Peak [W] Zone Latent Heat Gain at Ideal Loads Peak [W] Coil Total Capacity at Rating Conditions [W] Coil Sensible Capacity at Rating Conditions [W] Coil Air Mass Flow Rate at Rating Conditions [kg/s] Coil Entering Air Drybulb at Rating Conditions [C] Coil Entering Air Wetbulb at Rating Conditions [C] Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] Coil Leaving Air Drybulb at Rating Conditions [C] Coil Leaving Air Wetbulb at Rating Conditions [C] Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K]
PSZ-AC:1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:1 CORE_ZN Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 6553.418 5247.029 0.395892 -999.0 -999.000 -999.0000 1.13400 1.00000 1020.4856 1004.8586 0.9774 PSZ-AC:1 FAN Fan:OnOff 0.395892 0.38695972   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 16:10:00 Sensible 5946.91 5946.91 0.9075 0.38695972 0.395892 26.47 15.00 0.00841636 48060.3 12.80 10.14 0.00841636 34111.0 -999.0 -999.00 -999.00 -999.00 443.442 5503.47 32.81 0.00547359 14.72 0.06462207 16.3232 23.89 0.00899042 23.89 0.00899416 39.5319 3625.00 0.00 6552.29 4731.67 0.37167773 26.67 19.44 0.01118466 55322.4 14.21 13.42 0.00926411 37693.4
PSZ-AC:1 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:1 CORE_ZN Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 6553.418 6553.418 0.395892 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 0.9774 PSZ-AC:1 FAN Fan:OnOff 0.395892 0.38695972   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 unknown unknown DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 Sensible 6553.42 6553.42 1.0000 0.38695972 0.395892 14.74 9.39 0.00685007 32133.0 40.00 18.76 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 6553.42 -17.90 0.00095524 -17.90 0.06462207 16.3232 21.11 0.00800000 21.11 0.00800000 41.6969 1417.05 0.00 6562.03 6562.03 0.38012202 21.11 15.56 0.00875166 43444.1 38.02 21.14 0.00875166 60707.1
PSZ-AC:1_SUPPHEATCOIL Coil:Heating:Fuel AirLoop AirLoopHVAC PSZ-AC:1 CORE_ZN Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 4151.687 4151.687 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 0.9774 PSZ-AC:1 FAN Fan:OnOff 0.395892 0.38695972   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 unknown unknown DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 Sensible 4151.69 4151.69 1.0000 0.38695972 0.395892 14.74 9.39 0.00685007 32133.0 40.00 18.76 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 4151.69 -17.90 0.00095524 -17.90 0.06462207 16.3232 21.11 0.00800000 21.11 0.00800000 41.6969 1417.05 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
PSZ-AC:2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:2 PERIMETER_ZN_1 Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 7109.118 5691.952 0.429462 -999.0 -999.000 -999.0000 1.14276 1.00000 1020.4299 1004.8586 0.9774 PSZ-AC:2 FAN Fan:OnOff 0.429462 0.41977212   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 Sensible 6357.62 6357.62 0.8943 0.41977212 0.429462 26.15 14.87 0.00838640 47662.4 12.80 10.11 0.00838640 34035.4 -999.0 -999.00 -999.00 -999.00 481.044 5876.58 33.90 0.00547527 15.07 0.04898771 11.4068 23.89 0.00876122 23.89 0.00876122 38.5217 3959.20 0.00 7107.90 5132.90 0.40319429 26.67 19.44 0.01118466 55322.4 14.21 13.42 0.00926411 37693.4
PSZ-AC:2 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:2 PERIMETER_ZN_1 Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 7109.118 7109.118 0.429462 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 0.9774 PSZ-AC:2 FAN Fan:OnOff 0.429462 0.41977212   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 unknown unknown DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 Sensible 7109.12 7109.12 1.0000 0.41977212 0.429462 16.66 10.30 0.00700467 34475.3 40.00 18.76 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 7109.12 -17.90 0.00095524 -17.90 0.04898771 11.4068 21.11 0.00778356 21.11 0.00778356 40.5847 4423.59 0.00 7118.46 7118.46 0.41235461 21.11 15.56 0.00875166 43444.1 38.02 21.14 0.00875166 60707.1
PSZ-AC:2_SUPPHEATCOIL Coil:Heating:Fuel AirLoop AirLoopHVAC PSZ-AC:2 PERIMETER_ZN_1 Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 7107.914 7107.914 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 0.9774 PSZ-AC:2 FAN Fan:OnOff 0.429462 0.41977212   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 unknown unknown DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 Sensible 7107.91 7107.91 1.0000 0.41977212 0.429462 16.66 10.30 0.00700467 34475.3 40.00 18.76 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 7107.91 -17.90 0.00095524 -17.90 0.04898771 11.4068 21.11 0.00778356 21.11 0.00778356 40.5847 4423.59 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
PSZ-AC:3 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:3 PERIMETER_ZN_2 Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 5539.574 4435.289 0.334646 -999.0 -999.000 -999.0000 1.27015 1.00000 1020.4760 1004.8586 0.9774 PSZ-AC:3 FAN Fan:OnOff 0.334646 0.32709527   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 10:10:00 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 10:10:00 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 09:50:00 Sensible 5191.14 5191.14 0.9371 0.32709527 0.334646 25.36 14.63 0.00841122 46912.3 12.80 10.13 0.00841122 34098.0 -999.0 -999.00 -999.00 -999.00 374.839 4816.30 27.86 0.00546603 13.03 0.02906014 8.6839 23.89 0.00869129 23.89 0.00869258 38.2233 3077.15 0.00 5538.62 3999.66 0.31417748 26.67 19.44 0.01118466 55322.4 14.21 13.42 0.00926411 37693.4
PSZ-AC:3 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:3 PERIMETER_ZN_2 Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 5539.574 5539.574 0.334646 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 0.9774 PSZ-AC:3 FAN Fan:OnOff 0.334646 0.32709527   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 unknown unknown DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 Sensible 5539.57 5539.57 1.0000 0.32709527 0.334646 17.72 10.87 0.00718224 36006.4 40.00 18.76 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 5539.57 -17.90 0.00095524 -17.90 0.02906014 8.6839 21.11 0.00777441 21.11 0.00777441 40.5377 2825.63 0.00 5546.85 5546.85 0.32131540 21.11 15.56 0.00875166 43444.1 38.02 21.14 0.00875166 60707.1
PSZ-AC:3_SUPPHEATCOIL Coil:Heating:Fuel AirLoop AirLoopHVAC PSZ-AC:3 PERIMETER_ZN_2 Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 4454.788 4454.788 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 0.9774 PSZ-AC:3 FAN Fan:OnOff 0.334646 0.32709527   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 unknown unknown DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 Sensible 4454.79 4454.79 1.0000 0.32709527 0.334646 17.72 10.87 0.00718224 36006.4 40.00 18.76 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 4454.79 -17.90 0.00095524 -17.90 0.02906014 8.6839 21.11 0.00777441 21.11 0.00777441 40.5377 2825.63 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
PSZ-AC:4 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:4 PERIMETER_ZN_3 Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 6346.729 5081.542 0.383406 -999.0 -999.000 -999.0000 1.14807 1.00000 1020.3956 1004.8586 0.9774 PSZ-AC:4 FAN Fan:OnOff 0.383406 0.37475536   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:30:00 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:30:00 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 15:50:00 Sensible 5719.67 5719.67 0.9012 0.37475536 0.383406 26.20 14.87 0.00836795 47659.1 12.80 10.09 0.00836795 33988.8 -999.0 -999.00 -999.00 -999.00 429.456 5290.22 33.16 0.00547412 14.83 0.04898771 12.7770 23.89 0.00879186 23.89 0.00879249 38.6569 3528.08 0.00 6345.64 4582.44 0.35995536 26.67 19.44 0.01118466 55322.4 14.21 13.42 0.00926411 37693.4
PSZ-AC:4 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:4 PERIMETER_ZN_3 Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 6346.729 6346.729 0.383406 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 0.9774 PSZ-AC:4 FAN Fan:OnOff 0.383406 0.37475536   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 unknown unknown DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 Sensible 6346.73 6346.73 1.0000 0.37475536 0.383406 16.13 10.00 0.00690745 33685.2 40.00 18.76 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 6346.73 -17.90 0.00095524 -17.90 0.04898771 12.7770 21.11 0.00777937 21.11 0.00777937 40.5631 4336.89 0.00 6355.07 6355.07 0.36813332 21.11 15.56 0.00875166 43444.1 38.02 21.14 0.00875166 60707.1
PSZ-AC:4_SUPPHEATCOIL Coil:Heating:Fuel AirLoop AirLoopHVAC PSZ-AC:4 PERIMETER_ZN_3 Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 7005.389 7005.389 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 0.9774 PSZ-AC:4 FAN Fan:OnOff 0.383406 0.37475536   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 unknown unknown DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 Sensible 7005.39 7005.39 1.0000 0.37475536 0.383406 16.13 10.00 0.00690745 33685.2 40.00 18.76 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 7005.39 -17.90 0.00095524 -17.90 0.04898771 12.7770 21.11 0.00777937 21.11 0.00777937 40.5631 4336.89 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
PSZ-AC:5 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:5 PERIMETER_ZN_4 Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 7130.763 5709.283 0.430769 -999.0 -999.000 -999.0000 1.23493 1.00000 1020.5206 1004.8586 0.9774 PSZ-AC:5 FAN Fan:OnOff 0.430769 0.42105020   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:50:00 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:50:00 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB 7/21 17:50:00 Sensible 6550.42 6550.42 0.9186 0.42105020 0.430769 25.46 14.68 0.00843518 47083.4 12.80 10.15 0.00843518 34158.5 -999.0 -999.00 -999.00 -999.00 482.508 6067.91 30.59 0.00547019 13.98 0.02906014 6.7461 23.89 0.00864967 23.89 0.00864967 38.0372 3971.41 0.00 7129.54 5148.53 0.40442190 26.67 19.44 0.01118466 55322.4 14.21 13.42 0.00926411 37693.4
PSZ-AC:5 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:5 PERIMETER_ZN_4 Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 7130.763 7130.763 0.430769 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 0.9774 PSZ-AC:5 FAN Fan:OnOff 0.430769 0.42105020   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 unknown unknown DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 Sensible 7130.76 7130.76 1.0000 0.42105020 0.430769 18.48 11.28 0.00731438 37111.0 40.00 18.76 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 7130.76 -17.90 0.00095524 -17.90 0.02906014 6.7461 21.11 0.00777441 21.11 0.00777441 40.5377 2825.63 0.00 7140.13 7140.13 0.41361012 21.11 15.56 0.00875166 43444.1 38.02 21.14 0.00875166 60707.1
PSZ-AC:5_SUPPHEATCOIL Coil:Heating:Fuel AirLoop AirLoopHVAC PSZ-AC:5 PERIMETER_ZN_4 Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 4454.788 4454.788 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 0.9774 PSZ-AC:5 FAN Fan:OnOff 0.430769 0.42105020   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 unknown unknown DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB 12/21 24:00:00 Sensible 4454.79 4454.79 1.0000 0.42105020 0.430769 18.48 11.28 0.00731438 37111.0 40.00 18.76 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 4454.79 -17.90 0.00095524 -17.90 0.02906014 6.7461 21.11 0.00777441 21.11 0.00777441 40.5377 2825.63 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Outdoor Air Per Zone [m3/s] Outdoor Air ACH [ach] Outdoor Air Method Outdoor Air Schedule Name Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule Name
None                    


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
CORE_ZN 1998.67 2505.83 650.33
PERIMETER_ZN_1 2121.17 2653.00 1152.00
PERIMETER_ZN_2 2316.17 2341.00 1375.33
PERIMETER_ZN_3 2766.17 2977.83 1936.33
PERIMETER_ZN_4 2632.67 2893.17 1658.00
ATTIC 0.00 0.00 0.00
Facility 3410.83 3182.17 2123.17
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
CORE_ZN 0.50 0.50 0.50 0.50
PERIMETER_ZN_1 45.33 10.33 19.17 7.67
PERIMETER_ZN_2 73.50 0.17 2.67 0.00
PERIMETER_ZN_3 91.00 0.00 3.50 0.00
PERIMETER_ZN_4 73.00 6.33 2.33 0.33
ATTIC 0.00 0.00 0.00 0.00
Facility 220.17 17.33 20.83 8.50
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
CORE_ZN 4.75 8.05 456.46 0.394 0.000 0.000 0.000
PERIMETER_ZN_1 3.60 6.11 346.02 0.393 0.416 0.000 0.000
PERIMETER_ZN_2 1.93 3.62 205.26 0.368 0.062 0.000 0.000
PERIMETER_ZN_3 3.60 6.11 346.02 0.393 0.050 0.000 0.000
PERIMETER_ZN_4 2.13 3.62 205.26 0.394 0.057 0.000 0.000
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
CORE_ZN 4.75 8.05 456.46 0.000 0.000 0.000 0.000
PERIMETER_ZN_1 3.60 6.11 346.02 0.000 0.000 0.000 0.000
PERIMETER_ZN_2 1.93 3.62 205.26 0.000 0.000 0.000 0.000
PERIMETER_ZN_3 3.60 6.11 346.02 0.000 0.000 0.000 0.000
PERIMETER_ZN_4 2.13 3.62 205.26 0.000 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Outdoor Air Details

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

Mechanical Ventilation Parameters by Zone

AirLoop Name Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Zone Area [m2] Design Zone Outdoor Airflow - Voz [m3/s] Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s]
CORE_ZN PSZ-AC:1 4.75 8.05 456.46 149.66 0.0646 0.065
PERIMETER_ZN_1 PSZ-AC:2 3.60 6.11 346.02 113.45 0.0490 0.049
PERIMETER_ZN_2 PSZ-AC:3 1.93 3.62 205.26 67.30 0.0291 0.029
PERIMETER_ZN_3 PSZ-AC:4 3.60 6.11 346.02 113.45 0.0490 0.049
PERIMETER_ZN_4 PSZ-AC:5 2.13 3.62 205.26 67.30 0.0291 0.029
Total Facility   16.00 27.51 1559.03 511.16 0.2207 0.221


Total Outdoor Air by Zone

Mechanical Ventilation [m3] Natural Ventilation [m3] Total Ventilation [m3] Infiltration [m3] Total Ventilation and Infiltration [m3] Dynamic Target Ventilation - Voz-dyn [m3] Time Below Voz-dyn [hr] Time At Voz-dyn [hr] Time Above Voz-dyn [hr] Time Above Zero When Unoccupied [hr]
CORE_ZN 762126.79 0.00 762126.79 0.00 762126.79 2037921.45 5484.00 3276.00 0.00 0.00
PERIMETER_ZN_1 592254.26 0.00 592254.26 762929.19 1355183.46 1544876.42 5439.47 3320.53 0.00 146.23
PERIMETER_ZN_2 358899.33 0.00 358899.33 150025.23 508924.55 916440.58 5403.78 3356.22 0.00 1063.54
PERIMETER_ZN_3 616040.20 0.00 616040.20 225037.84 841078.03 1544876.42 5367.54 3392.46 0.00 345.89
PERIMETER_ZN_4 356431.79 0.00 356431.79 150025.23 506457.02 916440.58 5415.56 3344.44 0.00 321.94
Total Facility 2685752.37 0.00 2685752.37 1288017.48 3973769.86 6960555.45 5484.00 3432.18 0.00 1307.47


Average Outdoor Air During Occupancy by Zone - Flow Rates

Mechanical Ventilation [m3/s] Natural Ventilation [m3/s] Total Ventilation [m3/s] Infiltration [m3/s] Total Ventilation and Infiltration [m3/s] Dynamic Target Ventilation - Voz-dyn [m3/s] Time Below Voz-dyn [hr] Time At Voz-dyn [hr] Time Above Voz-dyn [hr]
CORE_ZN 0.0494 0.0000 0.0494 0.0000 0.0494 0.0646 1008.00 3276.00 0.00
PERIMETER_ZN_1 0.0375 0.0000 0.0375 0.0397 0.0772 0.0490 1006.36 3277.64 0.00
PERIMETER_ZN_2 0.0208 0.0000 0.0208 0.0035 0.0243 0.0291 1001.81 2526.19 0.00
PERIMETER_ZN_3 0.0375 0.0000 0.0375 0.0048 0.0423 0.0490 1002.87 3281.13 0.00
PERIMETER_ZN_4 0.0223 0.0000 0.0223 0.0032 0.0255 0.0291 1003.33 3280.67 0.00
Total Facility 0.1675 0.0000 0.1675 0.0512 0.2187 0.2207 1008.00 3284.11 0.00


Total Outdoor Air by AirLoop

Mechanical Ventilation [m3] Natural Ventilation [m3/s] Total Ventilation [m3/s] Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] Time Below Voz-sum-dyn [hr] Time At Voz-sum-dyn [hr] Time Above Voz-sum-dyn [hr] Time Above Zero When Unoccupied [hr]
PSZ-AC:1 728123.96 0.00 728123.96 2037921.45 8760.00 0.00 0.00 0.00
PSZ-AC:2 565830.42 0.00 565830.42 1544876.42 8760.00 0.00 0.00 145.15
PSZ-AC:3 342886.78 0.00 342886.78 916440.58 8760.00 0.00 0.00 1056.90
PSZ-AC:4 588555.12 0.00 588555.12 1544876.42 8760.00 0.00 0.00 343.04
PSZ-AC:5 340529.34 0.00 340529.34 916440.58 8760.00 0.00 0.00 311.49


Average Outdoor Air During Occupancy by AirLoop

Mechanical Ventilation [m3/s] Natural Ventilation [m3/s] Total Ventilation [m3/s] Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] Time Below Voz-sum-dyn [hr] Time At Voz-sum-dyn [hr] Time Above Voz-sum-dyn [hr]
PSZ-AC:1 0.0472 0.0000 0.0472 0.0646 4284.00 0.00 0.00
PSZ-AC:2 0.0358 0.0000 0.0358 0.0490 4284.00 0.00 0.00
PSZ-AC:3 0.0199 0.0000 0.0199 0.0291 3528.00 0.00 0.00
PSZ-AC:4 0.0358 0.0000 0.0358 0.0490 4284.00 0.00 0.00
PSZ-AC:5 0.0213 0.0000 0.0213 0.0291 4284.00 0.00 0.00


Outdoor Air Controller Limiting Factors by AirLoop

No Limiting Factor [hr] Limits and Scheduled Limits [hr] Economizer [hr] Exhaust Flow [hr] Mixed Air Flow [hr] High Humidity [hr] Demand Controlled Ventilation [hr] Night Ventilation [hr] Demand Limiting [hr] Energy Management System [hr]
PSZ-AC:1 0.00 3276.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PSZ-AC:2 0.00 3423.54 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PSZ-AC:3 0.00 3584.26 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PSZ-AC:4 0.00 3624.92 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PSZ-AC:5 0.00 3597.17 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Average Outdoor Air for Limiting Factors During Occupancy

No Limiting Factor [m3/s] Limits and Scheduled Limits [m3/s] Economizer [m3/s] Exhaust Flow [m3/s] Mixed Air Flow [m3/s] High Humidity [m3/s] Demand Controlled Ventilation [m3/s] Night Ventilation [m3/s] Demand Limiting [m3/s] Energy Management System [m3/s]
PSZ-AC:1 0.0000 0.0617 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
PSZ-AC:2 0.0000 0.0468 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
PSZ-AC:3 0.0000 0.0278 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
PSZ-AC:4 0.0000 0.0468 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
PSZ-AC:5 0.0000 0.0277 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000



Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

Surfaces by Class

Total Outdoors
Wall 20 4
Floor 14 8
Roof 9 4
Internal Mass 5 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 21 21
Door 2 2
Glass Door 1 1
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 5
Conditioned Zones 5
Unconditioned Zones 1
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 523
Defaulted Fields 365
Fields with Defaults 1332
Autosized Fields 115
Autosizable Fields 137
Autocalculated Fields 90
Autocalculatable Fields 156



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Electricity Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
Electricity:Facility 198.36 1803.03 19-FEB-13:30 20717.85 20-MAR-08:00
Electricity:Building 94.92 1231.03 19-FEB-13:30 6704.58 02-JAN-16:50
Electricity:Zone:CORE_ZN 29.05 392.60 01-JAN-00:10 1962.98 02-JAN-08:10
Electricity:SpaceType:GENERAL 94.92 1231.03 19-FEB-13:30 6704.58 02-JAN-16:50
InteriorLights:Electricity 42.12 537.90 19-FEB-13:30 3238.93 02-JAN-16:50
InteriorLights:Electricity:Zone:CORE_ZN 13.59 189.67 01-JAN-00:10 948.30 02-JAN-08:10
InteriorLights:Electricity:SpaceType:GENERAL 42.12 537.90 19-FEB-13:30 3238.93 02-JAN-16:50
LightsWired:InteriorLights:Electricity 42.12 537.90 19-FEB-13:30 3238.93 02-JAN-16:50
LightsWired:InteriorLights:Electricity:Zone:CORE_ZN 13.59 189.67 01-JAN-00:10 948.30 02-JAN-08:10
LightsWired:InteriorLights:Electricity:SpaceType:GENERAL 42.12 537.90 19-FEB-13:30 3238.93 02-JAN-16:50
Electricity:Zone:PERIMETER_ZN_1 20.45 263.12 01-JAN-07:50 1488.06 02-JAN-16:50
InteriorLights:Electricity:Zone:PERIMETER_ZN_1 8.73 109.29 01-JAN-07:50 718.87 02-JAN-16:50
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_ZN_1 8.73 109.29 01-JAN-07:50 718.87 02-JAN-16:50
Electricity:Zone:PERIMETER_ZN_2 12.28 156.09 01-JAN-08:00 882.74 02-JAN-16:50
InteriorLights:Electricity:Zone:PERIMETER_ZN_2 5.32 64.83 01-JAN-08:00 426.44 02-JAN-16:50
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_ZN_2 5.32 64.83 01-JAN-08:00 426.44 02-JAN-16:50
Electricity:Zone:PERIMETER_ZN_3 20.87 263.12 19-FEB-13:30 1488.06 02-JAN-16:50
InteriorLights:Electricity:Zone:PERIMETER_ZN_3 9.15 109.29 19-FEB-13:30 718.87 02-JAN-16:50
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_ZN_3 9.15 109.29 19-FEB-13:30 718.87 02-JAN-16:50
Electricity:Zone:PERIMETER_ZN_4 12.27 156.09 01-JAN-13:10 882.74 02-JAN-16:50
InteriorLights:Electricity:Zone:PERIMETER_ZN_4 5.32 64.83 01-JAN-13:10 426.44 02-JAN-16:50
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_ZN_4 5.32 64.83 01-JAN-13:10 426.44 02-JAN-16:50
InteriorEquipment:Electricity 52.80 693.13 01-JAN-00:10 3465.65 02-JAN-08:10
InteriorEquipment:Electricity:Zone:CORE_ZN 15.46 202.94 01-JAN-00:10 1014.68 02-JAN-08:10
InteriorEquipment:Electricity:SpaceType:GENERAL 52.80 693.13 01-JAN-00:10 3465.65 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity 52.80 693.13 01-JAN-00:10 3465.65 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_ZN 15.46 202.94 01-JAN-00:10 1014.68 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL 52.80 693.13 01-JAN-00:10 3465.65 02-JAN-08:10
InteriorEquipment:Electricity:Zone:PERIMETER_ZN_1 11.72 153.84 01-JAN-00:10 769.19 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_ZN_1 11.72 153.84 01-JAN-00:10 769.19 02-JAN-08:10
InteriorEquipment:Electricity:Zone:PERIMETER_ZN_2 6.95 91.26 01-JAN-00:10 456.29 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_ZN_2 6.95 91.26 01-JAN-00:10 456.29 02-JAN-08:10
InteriorEquipment:Electricity:Zone:PERIMETER_ZN_3 11.72 153.84 01-JAN-00:10 769.19 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_ZN_3 11.72 153.84 01-JAN-00:10 769.19 02-JAN-08:10
InteriorEquipment:Electricity:Zone:PERIMETER_ZN_4 6.95 91.26 01-JAN-00:10 456.29 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_ZN_4 6.95 91.26 01-JAN-00:10 456.29 02-JAN-08:10
ElectricityPurchased:Facility 198.36 1803.03 19-FEB-13:30 20717.85 20-MAR-08:00
ElectricityPurchased:Plant 198.36 1803.03 19-FEB-13:30 20717.85 20-MAR-08:00
Cogeneration:ElectricityPurchased 198.36 1803.03 19-FEB-13:30 20717.85 20-MAR-08:00
General:Cogeneration:ElectricityPurchased 198.36 1803.03 19-FEB-13:30 20717.85 20-MAR-08:00
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
ElectricityNet:Facility 198.36 1803.03 19-FEB-13:30 20717.85 20-MAR-08:00
ElectricityNet:Plant 198.36 1803.03 19-FEB-13:30 20717.85 20-MAR-08:00
Cogeneration:ElectricityNet 198.36 1803.03 19-FEB-13:30 20717.85 20-MAR-08:00
General:Cogeneration:ElectricityNet 198.36 1803.03 19-FEB-13:30 20717.85 20-MAR-08:00
ExteriorLights:Electricity 20.69 0.00 01-JAN-07:30 1574.40 01-JAN-06:10
General:ExteriorLights:Electricity 20.69 0.00 01-JAN-07:30 1574.40 01-JAN-06:10
Electricity:HVAC 57.77 0.00 01-JAN-13:30 12300.89 20-MAR-06:30
Fans:Electricity 27.03 0.00 01-JAN-11:30 2211.29 02-JAN-06:10
General:Fans:Electricity 27.03 0.00 01-JAN-11:30 2211.29 02-JAN-06:10
Cooling:Electricity 14.64 0.00 01-JAN-00:10 7344.76 26-JUN-15:00
General:Cooling:Electricity 14.64 0.00 01-JAN-00:10 7344.76 26-JUN-15:00
Heating:Electricity 16.10 0.00 01-JAN-13:30 10089.60 20-MAR-06:30
General:Heating:Electricity 16.10 0.00 01-JAN-13:30 10089.60 20-MAR-06:30
Electricity:Plant 24.98 572.00 14-JAN-09:00 2825.56 14-FEB-12:20
WaterSystems:Electricity 24.98 572.00 12-JAN-12:10 2825.56 14-FEB-12:20
Water Heater:WaterSystems:Electricity 24.98 572.00 12-JAN-12:10 2825.56 14-FEB-12:20
Pumps:Electricity 0.00 0.00 01-JAN-00:10 0.00 05-JAN-08:10
General:Pumps:Electricity 0.00 0.00 01-JAN-00:10 0.00 05-JAN-08:10


Annual and Peak Values - Natural Gas

Natural Gas Annual Value [GJ] Natural Gas Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Natural Gas Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
NaturalGas:Facility 11.19 0.00 01-JAN-00:10 33968.21 22-DEC-07:10
NaturalGas:HVAC 11.19 0.00 01-JAN-00:10 33968.21 22-DEC-07:10
Heating:NaturalGas 11.19 0.00 01-JAN-00:10 33968.21 22-DEC-07:10
General:Heating:NaturalGas 11.19 0.00 01-JAN-00:10 33968.21 22-DEC-07:10


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Cooling Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum {TIMESTAMP} Maximum Value [m3/s] Timestamp of Maximum {TIMESTAMP}
Water:Facility 58.31 0.00 01-JAN-00:10 0.00 02-JAN-12:10
Water:Plant 58.31 0.00 01-JAN-00:10 0.00 02-JAN-12:10
WaterSystems:Water 58.31 0.00 01-JAN-00:10 0.00 02-JAN-12:10
Water Heater:WaterSystems:Water 29.16 0.00 01-JAN-00:10 0.00 12-JAN-12:50
MainsWater:Facility 58.31 0.00 01-JAN-00:10 0.00 02-JAN-12:10
MainsWater:Plant 58.31 0.00 01-JAN-00:10 0.00 02-JAN-12:10
WaterSystems:MainsWater 58.31 0.00 01-JAN-00:10 0.00 02-JAN-12:10
Water Heater:WaterSystems:MainsWater 29.16 0.00 01-JAN-00:10 0.00 12-JAN-12:50
WaterUse:WaterSystems:Water 29.16 0.00 01-JAN-00:10 0.00 15-FEB-12:10
WaterUse:WaterSystems:MainsWater 29.16 0.00 01-JAN-00:10 0.00 15-FEB-12:10


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum {TIMESTAMP} Maximum Value [kg/s] Timestamp of Maximum {TIMESTAMP}
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:10 0.000 01-JAN-00:10
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:10 0.000 01-JAN-00:10


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum {TIMESTAMP} Maximum Value [m3/s] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum {TIMESTAMP} Maximum Value [L] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
EnergyTransfer:Facility 184.29 0.00 01-JAN-11:30 65892.57 06-FEB-07:10
EnergyTransfer:Building 85.26 0.00 01-JAN-11:30 30634.45 06-FEB-07:10
EnergyTransfer:Zone:CORE_ZN 18.03 0.00 01-JAN-00:10 5953.17 05-SEP-07:20
Heating:EnergyTransfer 29.47 0.00 01-JAN-11:30 30634.45 06-FEB-07:10
Heating:EnergyTransfer:Zone:CORE_ZN 0.80 0.00 01-JAN-00:10 4296.21 26-DEC-07:20
General:Heating:EnergyTransfer 29.47 0.00 01-JAN-11:30 30634.45 06-FEB-07:10
General:Heating:EnergyTransfer:Zone:CORE_ZN 0.80 0.00 01-JAN-00:10 4296.21 26-DEC-07:20
Cooling:EnergyTransfer 55.79 0.00 01-JAN-00:10 21620.07 17-JUL-07:10
Cooling:EnergyTransfer:Zone:CORE_ZN 17.23 0.00 01-JAN-00:10 5953.17 05-SEP-07:20
General:Cooling:EnergyTransfer 55.79 0.00 01-JAN-00:10 21620.07 17-JUL-07:10
General:Cooling:EnergyTransfer:Zone:CORE_ZN 17.23 0.00 01-JAN-00:10 5953.17 05-SEP-07:20
EnergyTransfer:Zone:PERIMETER_ZN_1 22.09 0.00 01-JAN-00:10 9140.35 06-FEB-07:10
Heating:EnergyTransfer:Zone:PERIMETER_ZN_1 7.26 0.00 01-JAN-00:10 9140.35 06-FEB-07:10
General:Heating:EnergyTransfer:Zone:PERIMETER_ZN_1 7.26 0.00 01-JAN-00:10 9140.35 06-FEB-07:10
Cooling:EnergyTransfer:Zone:PERIMETER_ZN_1 14.82 0.00 01-JAN-00:10 6234.24 10-OCT-12:10
General:Cooling:EnergyTransfer:Zone:PERIMETER_ZN_1 14.82 0.00 01-JAN-00:10 6234.24 10-OCT-12:10
EnergyTransfer:Zone:PERIMETER_ZN_2 13.36 0.00 01-JAN-00:40 4903.90 06-FEB-07:10
Heating:EnergyTransfer:Zone:PERIMETER_ZN_2 5.10 0.00 01-JAN-00:40 4903.90 06-FEB-07:10
General:Heating:EnergyTransfer:Zone:PERIMETER_ZN_2 5.10 0.00 01-JAN-00:40 4903.90 06-FEB-07:10
Cooling:EnergyTransfer:Zone:PERIMETER_ZN_2 8.26 0.00 01-JAN-00:10 4503.27 17-JUL-08:30
General:Cooling:EnergyTransfer:Zone:PERIMETER_ZN_2 8.26 0.00 01-JAN-00:10 4503.27 17-JUL-08:30
EnergyTransfer:Zone:PERIMETER_ZN_3 19.13 0.00 01-JAN-00:10 7509.11 13-FEB-07:10
Heating:EnergyTransfer:Zone:PERIMETER_ZN_3 10.68 0.00 01-JAN-00:10 7509.11 13-FEB-07:10
General:Heating:EnergyTransfer:Zone:PERIMETER_ZN_3 10.68 0.00 01-JAN-00:10 7509.11 13-FEB-07:10
Cooling:EnergyTransfer:Zone:PERIMETER_ZN_3 8.44 0.00 01-JAN-00:10 4543.23 17-JUL-13:40
General:Cooling:EnergyTransfer:Zone:PERIMETER_ZN_3 8.44 0.00 01-JAN-00:10 4543.23 17-JUL-13:40
EnergyTransfer:Zone:PERIMETER_ZN_4 12.66 0.00 01-JAN-00:40 4959.79 06-FEB-07:10
Heating:EnergyTransfer:Zone:PERIMETER_ZN_4 5.63 0.00 01-JAN-00:40 4959.79 06-FEB-07:10
General:Heating:EnergyTransfer:Zone:PERIMETER_ZN_4 5.63 0.00 01-JAN-00:40 4959.79 06-FEB-07:10
Cooling:EnergyTransfer:Zone:PERIMETER_ZN_4 7.03 0.00 01-JAN-00:10 4086.40 26-JUN-16:00
General:Cooling:EnergyTransfer:Zone:PERIMETER_ZN_4 7.03 0.00 01-JAN-00:10 4086.40 26-JUN-16:00
EnergyTransfer:Zone:ATTIC 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Heating:EnergyTransfer:Zone:ATTIC 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Heating:EnergyTransfer:Zone:ATTIC 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Cooling:EnergyTransfer:Zone:ATTIC 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Cooling:EnergyTransfer:Zone:ATTIC 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
PlantLoopHeatingDemand:Facility 0.00 -0.00 14-FEB-07:10 102.15 02-JAN-07:10
PlantLoopHeatingDemand:Plant 0.00 -0.00 14-FEB-07:10 102.15 02-JAN-07:10
WaterSystems:PlantLoopHeatingDemand 0.00 -0.00 14-FEB-07:10 102.15 02-JAN-07:10
General:WaterSystems:PlantLoopHeatingDemand 0.00 -0.00 14-FEB-07:10 102.15 02-JAN-07:10
EnergyTransfer:HVAC 99.03 0.00 01-JAN-11:30 35258.01 06-FEB-07:10
CoolingCoils:EnergyTransfer 63.12 0.00 01-JAN-00:10 25441.26 17-JUL-14:10
HeatingCoils:EnergyTransfer 35.90 0.00 01-JAN-11:30 35258.01 06-FEB-07:10
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
EnergyTransfer:Plant 0.00 -0.00 14-FEB-07:10 102.15 02-JAN-07:10
WaterSystems:EnergyTransfer 0.00 -0.00 14-FEB-07:10 102.15 02-JAN-07:10
WaterUse:WaterSystems:EnergyTransfer 0.00 -0.00 14-FEB-07:10 102.15 02-JAN-07:10



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

Annual Building Sensible Heat Gain Components

HVAC Zone Eq & Other Sensible Air Heating [GJ] HVAC Zone Eq & Other Sensible Air Cooling [GJ] HVAC Terminal Unit Sensible Air Heating [GJ] HVAC Terminal Unit Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
CORE_ZN 0.000 0.000 0.799 -17.232 0.000 0.000 5.234 13.590 15.459 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 -17.851
PERIMETER_ZN_1 0.000 0.000 7.263 -14.823 0.000 0.000 3.993 8.730 11.719 29.687 0.000 0.500 0.000 0.000 -11.242 0.000 -9.154 -26.675
PERIMETER_ZN_2 0.000 0.000 5.097 -8.260 0.000 0.000 1.757 5.324 6.952 12.034 0.000 0.026 0.000 0.000 -5.794 0.000 -1.891 -15.246
PERIMETER_ZN_3 0.000 0.000 10.683 -8.444 0.000 0.000 4.110 9.153 11.719 5.629 0.000 0.046 0.000 0.000 -8.767 0.000 -2.724 -21.405
PERIMETER_ZN_4 0.000 0.000 5.626 -7.034 0.000 0.000 2.395 5.320 6.952 11.030 0.000 0.027 0.000 0.000 -6.015 0.000 -1.922 -16.378
ATTIC 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 9.100 25.722 0.000 0.000 0.000 -34.823 -0.000
Total Facility 0.000 0.000 29.468 -55.792 0.000 0.000 17.490 42.118 52.800 58.379 0.000 9.699 25.723 0.000 -31.817 0.000 -50.513 -97.555


Peak Cooling Sensible Heat Gain Components

Time of Peak {TIMESTAMP} HVAC Zone Eq & Other Sensible Air Heating [W] HVAC Zone Eq & Other Sensible Air Cooling [W] HVAC Terminal Unit Sensible Air Heating [W] HVAC Terminal Unit Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
CORE_ZN 03-JUL-06:02 0.00 0.00 0.00 -6606.38 0.00 0.00 91.09 442.53 507.34 0.00 0.00 0.00 5565.41 0.00 -0.00 0.00 0.00 0.00
PERIMETER_ZN_1 05-SEP-06:02 0.00 0.00 0.00 -6544.30 0.00 0.00 70.86 325.82 384.60 0.00 0.00 0.00 7797.00 0.00 -427.94 0.00 -1606.04 0.00
PERIMETER_ZN_2 21-AUG-06:01 0.00 0.00 0.00 -4999.13 0.00 0.00 38.14 160.52 228.15 742.59 0.00 0.00 3841.77 0.00 -0.00 0.00 -12.04 0.00
PERIMETER_ZN_3 03-JUL-07:02 0.00 0.00 0.00 -5943.53 0.00 0.00 385.70 590.59 769.19 11.19 0.00 0.00 4196.32 0.00 -0.00 0.00 -9.46 0.00
PERIMETER_ZN_4 21-AUG-06:01 0.00 0.00 0.00 -6251.34 0.00 0.00 38.14 186.28 228.15 0.00 0.00 0.00 5850.95 0.00 -40.64 0.00 -11.53 0.00
ATTIC - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 21-AUG-06:01 0.00 0.00 0.00 -29922.98 0.00 0.00 300.59 1359.89 1732.82 831.08 0.00 748.37 25956.72 0.00 -104.86 0.00 -901.63 0.00


Peak Heating Sensible Heat Gain Components

Time of Peak {TIMESTAMP} HVAC Zone Eq & Other Sensible Air Heating [W] HVAC Zone Eq & Other Sensible Air Cooling [W] HVAC Terminal Unit Sensible Air Heating [W] HVAC Terminal Unit Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
CORE_ZN 09-JAN-07:01 0.00 0.00 8392.35 0.00 0.00 0.00 159.89 442.53 507.34 0.00 0.00 0.00 0.00 0.00 -0.00 0.00 0.00 -9502.11
PERIMETER_ZN_1 24-APR-05:01 0.00 0.00 10086.20 0.00 0.00 0.00 68.88 183.71 384.60 0.00 0.00 0.00 0.00 0.00 -652.76 0.00 -421.38 -9649.26
PERIMETER_ZN_2 06-MAR-06:01 0.00 0.00 7643.57 0.00 0.00 0.00 40.45 108.98 228.15 0.00 0.00 0.00 0.00 0.00 -306.64 0.00 -134.39 -7580.12
PERIMETER_ZN_3 05-MAR-08:51 0.00 0.00 9427.86 0.00 0.00 0.00 0.00 122.46 153.84 0.00 0.00 0.00 0.00 0.00 -52.50 0.00 -180.39 -9471.27
PERIMETER_ZN_4 09-JAN-06:01 0.00 0.00 9725.84 0.00 0.00 0.00 40.97 108.98 228.15 0.00 0.00 0.00 0.00 0.00 -249.44 0.00 -51.49 -9803.01
ATTIC - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 09-JAN-07:01 0.00 0.00 41439.20 0.00 0.00 0.00 546.10 1511.48 1732.82 0.00 0.00 799.96 0.00 0.00 -1460.16 0.00 -2031.84 -42537.59



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Origin of D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Calculation Method for Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA Environment Name of Peak System Population - Ps Date and Time of Last Peak System Population - Ps
PSZ-AC:1 0.3959 0.0000 8.0545 1.0000 Calculated from schedules 0.0646 0.3959 0.1632 1.0000 Not calculated 0.0646 0.1632    
PSZ-AC:2 0.4295 0.0000 6.1058 1.0000 Calculated from schedules 0.0490 0.4295 0.1141 1.0000 Not calculated 0.0490 0.1141    
PSZ-AC:3 0.3346 0.0000 3.6221 1.0000 Calculated from schedules 0.0291 0.3346 0.0868 1.0000 Not calculated 0.0291 0.0868    
PSZ-AC:4 0.3834 0.0000 6.1058 1.0000 Calculated from schedules 0.0490 0.3834 0.1278 1.0000 Not calculated 0.0490 0.1278    
PSZ-AC:5 0.4308 0.0000 3.6221 1.0000 Calculated from schedules 0.0291 0.4308 0.0675 1.0000 Not calculated 0.0291 0.0675    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Origin of D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Calculation Method for Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA Environment Name of Peak System Population - Ps Date and Time of Last Peak System Population - Ps
PSZ-AC:1 0.3959 0.0000 8.0545 1.0000 Calculated from schedules 0.0646 0.3959 1.0000 1.0000 Not calculated 0.0646 0.1632    
PSZ-AC:2 0.4295 0.0000 6.1058 1.0000 Calculated from schedules 0.0490 0.4295 1.0000 1.0000 Not calculated 0.0490 0.1141    
PSZ-AC:3 0.3346 0.0000 3.6221 1.0000 Calculated from schedules 0.0291 0.3346 1.0000 1.0000 Not calculated 0.0291 0.0868    
PSZ-AC:4 0.3834 0.0000 6.1058 1.0000 Calculated from schedules 0.0490 0.3834 1.0000 1.0000 Not calculated 0.0490 0.1278    
PSZ-AC:5 0.4308 0.0000 3.6221 1.0000 Calculated from schedules 0.0291 0.4308 1.0000 1.0000 Not calculated 0.0291 0.0675    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
CORE_ZN PSZ-AC:1 0.000000 8.0545 0.000432 149.66 0.0646 1.0000 0.0646 1.000 0.0646
PERIMETER_ZN_1 PSZ-AC:2 0.000000 6.1058 0.000432 113.45 0.0490 1.0000 0.0490 1.000 0.0490
PERIMETER_ZN_2 PSZ-AC:3 0.000000 3.6221 0.000432 67.30 0.0291 1.0000 0.0291 1.000 0.0291
PERIMETER_ZN_3 PSZ-AC:4 0.000000 6.1058 0.000432 113.45 0.0490 1.0000 0.0490 1.000 0.0490
PERIMETER_ZN_4 PSZ-AC:5 0.000000 3.6221 0.000432 67.30 0.0291 1.0000 0.0291 1.000 0.0291


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
PSZ-AC:1 0.000000 8.05 0.000432 149.6574 0.0646 0.0646 0.0646
PSZ-AC:2 0.000000 6.11 0.000432 113.4500 0.0490 0.0490 0.0490
PSZ-AC:3 0.000000 3.62 0.000432 67.3000 0.0291 0.0291 0.0291
PSZ-AC:4 0.000000 6.11 0.000432 113.4500 0.0490 0.0490 0.0490
PSZ-AC:5 0.000000 3.62 0.000432 67.3000 0.0291 0.0291 0.0291


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
CORE_ZN PSZ-AC:1 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3959 0.3959 0.3959 No 0.0646 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_ZN_1 PSZ-AC:2 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.4295 0.4295 0.4295 No 0.0490 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_ZN_2 PSZ-AC:3 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3346 0.3346 0.3346 No 0.0291 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_ZN_3 PSZ-AC:4 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3834 0.3834 0.3834 No 0.0490 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_ZN_4 PSZ-AC:5 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.4308 0.4308 0.4308 No 0.0291 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
PSZ-AC:1 0.3959 0.3959 0.3959 0.3959 0.0646 1.0000
PSZ-AC:2 0.4295 0.4295 0.4295 0.4295 0.0490 1.0000
PSZ-AC:3 0.3346 0.3346 0.3346 0.3346 0.0291 1.0000
PSZ-AC:4 0.3834 0.3834 0.3834 0.3834 0.0490 1.0000
PSZ-AC:5 0.4308 0.4308 0.4308 0.4308 0.0291 1.0000


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
CORE_ZN PSZ-AC:1 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3959 0.3959 0.3959 No 0.0646 0.7155 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_ZN_1 PSZ-AC:2 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.4295 0.4295 0.4295 No 0.0490 0.1738 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_ZN_2 PSZ-AC:3 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3346 0.3346 0.3346 No 0.0291 0.1614 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_ZN_3 PSZ-AC:4 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3834 0.3834 0.3834 No 0.0490 0.1772 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_ZN_4 PSZ-AC:5 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.4308 0.4308 0.4308 No 0.0291 0.1614 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
PSZ-AC:1 0.3959 0.3959 0.3959 0.3959 0.0646 1.0000
PSZ-AC:2 0.4295 0.4295 0.4295 0.4295 0.0490 1.0000
PSZ-AC:3 0.3346 0.3346 0.3346 0.3346 0.0291 1.0000
PSZ-AC:4 0.3834 0.3834 0.3834 0.3834 0.0490 1.0000
PSZ-AC:5 0.4308 0.4308 0.4308 0.4308 0.0291 1.0000



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

Sec1.1A-General Information

Data
Weather File RUNPERIOD 1 ** Denver-Aurora-Buckley AFB CO USA TMY3 WMO#=724695
Total gross floor area [m2] 511.16
Principal Heating Source Electricity


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
CORE_ZN 149.66 149.66 0.00 82.16
PERIMETER_ZN_1 113.45 113.45 0.00 82.16
PERIMETER_ZN_2 67.30 67.30 0.00 67.66
PERIMETER_ZN_3 113.45 113.45 0.00 82.16
PERIMETER_ZN_4 67.30 67.30 0.00 82.16
ATTIC 567.98 0.00 567.98 0.00
Totals 511.16 511.16 0.00  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 20.83
Number of hours cooling loads not met 8.50
Number of hours not met 29.33


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electricity Energy Use [GJ] Electricity Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Gasoline Use [GJ] Gasoline Demand [W] Diesel Use [GJ] Diesel Demand [W] Coal Use [GJ] Coal Demand [W] Fuel Oil No 1 Use [GJ] Fuel Oil No 1 Demand [W] Fuel Oil No 2 Use [GJ] Fuel Oil No 2 Demand [W] Propane Use [GJ] Propane Demand [W] Other Fuel 1 Use [GJ] Other Fuel 1 Demand [W] Other Fuel 2 Use [GJ] Other Fuel 2 Demand [W] District Cooling Use [GJ] District Cooling Demand [W] District Heating Use [GJ] District Heating Demand [W]
Heating -- General 16.10 10089.60 11.19 33968.21 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling -- General 14.64 7344.76 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting -- LightsWired 42.12 3238.93 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting -- General 20.69 1574.40 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment -- MiscPlug 52.80 3465.65 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans -- General 27.03 2211.29 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps -- General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems -- General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems -- Water Heater 24.98 2825.56 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems -- WaterUse 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators -- General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 52.80 198.36
Natural Gas 0.00 11.19
Additional 0.00 0.00
Total 52.80 209.55


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting (All) 82.40
Space Heating 31.49
Space Cooling 28.64
Fans (All) 52.88
Service Water Heating 48.86
Receptacle Equipment 103.29
Miscellaneous (All) 388.05
Subtotal 388.05


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 21.90
Service Water Heating 0.00
Miscellaneous (All) 21.90
Subtotal 21.90


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Subtotal 0.00
Miscellaneous 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting (All) 20.10
Space Heating 13.02
Space Cooling 6.99
Fans (All) 12.90
Service Water Heating 11.92
Receptacle Equipment 25.20
Miscellaneous 9.88


Schedules-Equivalent Full Load Hours (Schedule Type=Fraction)

Equivalent Full Load Hours of Operation Per Year [hr] Hours > 1% [hr]
LTG_SCH_OFFICE 2841. 8760.
BLDG_EQUIP_SCH 4310. 8760.
BLDG_OCC_SCH 2512. 4420.
BLDG_OCC_SCH_W_SB 1854. 3640.
BLDG_OCC_SCH_WO_SB 2533. 4420.
BINARY OCCUPANCY 4420. 4420.
INFIL_QUARTER_ON_SCH 5991. 8760.
INFIL_DOOR_OPENING_SCH 1154. 3380.
BLDG_SWH_SCH 2064. 3900.
ALWAYS_ON 8760. 8760.
EXTERIOR_LGT_ALWAYS_ON 8760. 8760.
EXTERIOR_LGT_189_1 6200. 8760.
ALWAYS_OFF 0. 0.
HVACOPERATIONSCHD_W_SB 2600. 2600.
REHEATCOILAVAILSCHED 8760. 8760.
COOLINGCOILAVAILSCHED 8760. 8760.
MINOA_MOTORIZEDDAMPER_SCHED 3120. 3120.
MINOA_SCHED 8760. 8760.
WORK_EFF_SCH 0. 0.
CORE_ZN WATER EQUIPMENT LATENT FRACT SCHED 438. 8760.
CORE_ZN WATER EQUIPMENT SENSIBLE FRACT SCHED 1752. 8760.
EXTERIOR_LIGHTING_SCHEDULE_A 6570. 6570.
EXTERIOR_LIGHTING_SCHEDULE_B 8103. 8760.
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 3120. 3120.
EXTERIOR_LIGHTING_SCHEDULE_B_2016 7665. 8760.
EXTERIOR_LIGHTING_SCHEDULE_C_2016 6752. 8760.


Schedules-SetPoints (Schedule Type=Temperature)

First Object Used Month Assumed 11am First Wednesday [C] Days with Same 11am Value 11pm First Wednesday [C] Days with Same 11pm Value
HTGSETP_SCH_YES_OPTIMUM CORE_ZN DUAL SP CONTROL January 21.11 365 15.56 365
CLGSETP_SCH_YES_OPTIMUM CORE_ZN DUAL SP CONTROL July 23.89 365 29.44 365



Table of Contents

Report: Annual Thermal Resilience Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

Heat Index Hours

Safe (≤ 26.7°C) [hr] Caution (> 26.7, ≤ 32.2°C) [hr] Extreme Caution (> 32.2, ≤ 39.4°C) [hr] Danger (> 39.4, ≤ 51.7°C) [hr] Extreme Danger (> 51.7°C) [hr]
CORE_ZN 8302.83 457.17 0.00 0.00 0.00
PERIMETER_ZN_1 8481.50 278.50 0.00 0.00 0.00
PERIMETER_ZN_2 8377.33 382.67 0.00 0.00 0.00
PERIMETER_ZN_3 8660.00 100.00 0.00 0.00 0.00
PERIMETER_ZN_4 8303.00 457.00 0.00 0.00 0.00
ATTIC 6850.50 594.50 561.17 746.50 7.33
Min 6850.50 100.00 0.00 0.00 0.00
Max 8660.00 594.50 561.17 746.50 7.33
Average 8162.53 378.31 93.53 124.42 1.22
Sum 48975.17 2269.83 561.17 746.50 7.33


Heat Index OccupantHours

Safe (≤ 26.7°C) [hr] Caution (> 26.7, ≤ 32.2°C) [hr] Extreme Caution (> 32.2, ≤ 39.4°C) [hr] Danger (> 39.4, ≤ 51.7°C) [hr] Extreme Danger (> 51.7°C) [hr]
CORE_ZN 17892.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_1 13356.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_2 4788.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_3 13356.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_4 6804.00 0.00 0.00 0.00 0.00
ATTIC 0.00 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00 0.00
Max 17892.00 0.00 0.00 0.00 0.00
Average 9366.00 0.00 0.00 0.00 0.00
Sum 56196.00 0.00 0.00 0.00 0.00


Humidex Hours

Little to no Discomfort (≤ 29) [hr] Some Discomfort (> 29, ≤ 40) [hr] Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] Dangerous (> 45, ≤ 50) [hr] Heat Stroke Quite Possible (> 50) [hr]
CORE_ZN 8297.33 462.67 0.00 0.00 0.00
PERIMETER_ZN_1 8633.50 126.50 0.00 0.00 0.00
PERIMETER_ZN_2 8604.33 155.67 0.00 0.00 0.00
PERIMETER_ZN_3 8705.50 54.50 0.00 0.00 0.00
PERIMETER_ZN_4 8601.33 158.67 0.00 0.00 0.00
ATTIC 7080.67 828.83 317.17 271.33 262.00
Min 7080.67 54.50 0.00 0.00 0.00
Max 8705.50 828.83 317.17 271.33 262.00
Average 8320.44 297.81 52.86 45.22 43.67
Sum 49922.67 1786.83 317.17 271.33 262.00


Humidex OccupantHours

Little to no Discomfort (≤ 29) [hr] Some Discomfort (> 29, ≤ 40) [hr] Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] Dangerous (> 45, ≤ 50) [hr] Heat Stroke Quite Possible (> 50) [hr]
CORE_ZN 17887.67 4.33 0.00 0.00 0.00
PERIMETER_ZN_1 13355.83 0.17 0.00 0.00 0.00
PERIMETER_ZN_2 4788.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_3 13355.00 1.00 0.00 0.00 0.00
PERIMETER_ZN_4 6804.00 0.00 0.00 0.00 0.00
ATTIC 0.00 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00 0.00
Max 17887.67 4.33 0.00 0.00 0.00
Average 9365.08 0.92 0.00 0.00 0.00
Sum 56190.50 5.50 0.00 0.00 0.00


Heating SET Hours

SET ≤ 12.2°C Hours (°C) SET ≤ 12.2°C OccupantHours (°C) Longest SET ≤ 12.2°C Duration [hr] Start Time of the Longest SET ≤ 12.2°C Duration
None        


Cooling SET Hours

SET > 30°C Hours (°C) SET > 30°C OccupantHours (°C) Longest SET > 30°C Duration [hr] Start Time of the Longest SET > 30°C Duration
None        



Table of Contents

Report: Annual CO2 Resilience Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

CO2 Level Hours

Safe (<= 1000 ppm) [hr] Caution (> 1000, <= 5000 ppm) [hr] Hazard (> 5000 ppm) [hr]
None      


CO2 Level OccupantHours

Safe (<= 1000 ppm) [hr] Caution (> 1000, <= 5000 ppm) [hr] Hazard (> 5000 ppm) [hr]
None      



Table of Contents

Report: Annual Visual Resilience Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:19

Illuminance Level Hours

A Bit Dark (<= 100 lux) [hr] Dim (> 100, <= 300 lux) [hr] Adequate (> 300, <= 500 lux) [hr] Bright (>500 lux) [hr]
CORE_ZN 0.00 0.00 0.00 0.00
PERIMETER_ZN_1 0.00 0.00 8760.00 0.00
PERIMETER_ZN_2 0.00 0.00 8760.00 0.00
PERIMETER_ZN_3 0.00 0.00 8760.00 0.00
PERIMETER_ZN_4 0.00 0.00 8760.00 0.00
ATTIC 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00
Max 0.00 0.00 8760.00 0.00
Average 0.00 0.00 5840.00 0.00
Sum 0.00 0.00 35040.00 0.00


Illuminance Level OccupantHours

A Bit Dark (<= 100 lux) [hr] Dim (> 100, <= 300 lux) [hr] Adequate (> 300, <= 500 lux) [hr] Bright (>500 lux) [hr]
CORE_ZN 0.00 0.00 0.00 0.00
PERIMETER_ZN_1 0.00 0.00 13356.00 0.00
PERIMETER_ZN_2 0.00 0.00 4788.00 0.00
PERIMETER_ZN_3 0.00 0.00 13356.00 0.00
PERIMETER_ZN_4 0.00 0.00 6804.00 0.00
ATTIC 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00
Max 0.00 0.00 13356.00 0.00
Average 0.00 0.00 6384.00 0.00
Sum 0.00 0.00 38304.00 0.00



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR

For: Environment

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 0.846
February -0.25
March 4.824
April 6.083
May 13.735
June 22.164
July 22.707
August 21.737
September 18.538
October 7.117
November 3.031
December -1.01
   
Annual Sum or Average 10.017
Minimum of Months -1.01
Maximum of Months 22.707



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC

For: Environment

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 0.846
February -0.25
March 4.824
April 6.083
May 13.735
June 22.164
July 22.707
August 21.737
September 18.538
October 7.117
November 3.031
December -1.01
   
Annual Sum or Average 10.017
Minimum of Months -1.01
Maximum of Months 22.707



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2015

For: Environment

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 0.846
February -0.25
March 4.824
April 6.083
May 13.735
June 22.164
July 22.707
August 21.737
September 18.538
October 7.117
November 3.031
December -1.01
   
Annual Sum or Average 10.017
Minimum of Months -1.01
Maximum of Months 22.707



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND

For: Environment

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 0.846
February -0.25
March 4.824
April 6.083
May 13.735
June 22.164
July 22.707
August 21.737
September 18.538
October 7.117
November 3.031
December -1.01
   
Annual Sum or Average 10.017
Minimum of Months -1.01
Maximum of Months 22.707



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME OFFICESMALL

For: Environment

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 0.846
February -0.25
March 4.824
April 6.083
May 13.735
June 22.164
July 22.707
August 21.737
September 18.538
October 7.117
November 3.031
December -1.01
   
Annual Sum or Average 10.017
Minimum of Months -1.01
Maximum of Months 22.707



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL

For: Environment

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 0.846
February -0.25
March 4.824
April 6.083
May 13.735
June 22.164
July 22.707
August 21.737
September 18.538
October 7.117
November 3.031
December -1.01
   
Annual Sum or Average 10.017
Minimum of Months -1.01
Maximum of Months 22.707



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL

For: Environment

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 0.846
February -0.25
March 4.824
April 6.083
May 13.735
June 22.164
July 22.707
August 21.737
September 18.538
October 7.117
November 3.031
December -1.01
   
Annual Sum or Average 10.017
Minimum of Months -1.01
Maximum of Months 22.707



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 5B

For: Environment

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 0.846
February -0.25
March 4.824
April 6.083
May 13.735
June 22.164
July 22.707
August 21.737
September 18.538
October 7.117
November 3.031
December -1.01
   
Annual Sum or Average 10.017
Minimum of Months -1.01
Maximum of Months 22.707



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_CO_DENVER

For: Environment

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 0.846
February -0.25
March 4.824
April 6.083
May 13.735
June 22.164
July 22.707
August 21.737
September 18.538
October 7.117
November 3.031
December -1.01
   
Annual Sum or Average 10.017
Minimum of Months -1.01
Maximum of Months 22.707



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.456297E+09 1771.02 05-JAN-06:01 -17.0 -17.0 0.244332E+09 402.33 27-JAN-14:39 9.67 5.30
February 0.430707E+09 1555.47 02-FEB-07:04 -9.7 -9.7 0.216115E+09 402.33 17-FEB-16:49 13.17 6.53
March 0.708000E+09 2211.93 15-MAR-15:55 19.00 5.38 0.282821E+09 402.35 17-MAR-09:30 6.50 6.21
April 0.499269E+09 1731.56 21-APR-14:22 14.50 5.42 0.254246E+09 402.35 13-APR-13:09 14.50 5.42
May 0.123673E+10 6048.97 17-MAY-07:01 19.50 10.18 0.306009E+09 456.24 18-MAY-07:10 18.17 10.10
June 0.283613E+10 6335.32 09-JUN-07:02 12.57 5.42 0.317219E+09 469.22 26-JUN-07:10 22.07 12.41
July 0.282889E+10 6606.36 03-JUL-06:02 11.00 7.64 0.288937E+09 469.22 03-JUL-07:10 11.33 7.79
August 0.311817E+10 6359.20 15-AUG-06:03 13.17 10.14 0.331758E+09 469.22 15-AUG-07:10 14.00 10.42
September 0.249507E+10 6516.33 05-SEP-06:02 13.90 7.58 0.287496E+09 469.22 13-SEP-07:10 20.18 12.26
October 0.138024E+10 6489.16 02-OCT-07:03 3.00 3.00 0.283740E+09 465.33 11-OCT-07:10 13.67 5.23
November 0.780066E+09 1933.36 09-NOV-14:18 19.33 8.45 0.262347E+09 402.35 10-NOV-11:00 4.00 4.00
December 0.462119E+09 1970.80 22-DEC-06:02 -20.8 -20.9 0.231317E+09 402.33 14-DEC-16:40 -20.8 -20.9
                     
Annual Sum or Average 0.172317E+11         0.330634E+10        
Minimum of Months 0.430707E+09 1555.47   -20.8 -20.9 0.216115E+09 402.33   -20.8 -20.9
Maximum of Months 0.311817E+10 6606.36   19.50 10.18 0.331758E+09 469.22   22.07 12.41



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.542449E+09 3755.80 20-JAN-14:37 20.33 6.84 0.191906E+09 304.99 10-JAN-15:30 20.33 6.84
February 0.353676E+09 2837.04 27-FEB-14:15 14.00 4.75 0.170760E+09 304.99 17-FEB-13:09 14.00 4.75
March 0.568831E+09 4178.73 15-MAR-14:00 21.00 6.28 0.211162E+09 304.99 08-MAR-13:09 21.00 6.28
April 0.168728E+09 1845.27 21-APR-13:30 15.50 6.04 0.180296E+09 305.97 07-APR-10:00 15.50 6.04
May 0.423975E+09 2256.17 18-MAY-14:10 23.83 11.33 0.218492E+09 305.00 24-MAY-10:00 21.00 12.14
June 0.210249E+10 6296.51 26-JUN-07:01 22.07 12.41 0.238521E+09 355.69 27-JUN-07:10 22.47 9.00
July 0.215264E+10 6264.29 17-JUL-06:01 22.50 11.12 0.217371E+09 355.70 19-JUL-07:10 21.33 14.20
August 0.285148E+10 6496.72 21-AUG-06:01 19.75 12.40 0.250194E+09 355.70 21-AUG-07:10 21.17 13.07
September 0.277452E+10 6544.55 05-SEP-06:02 13.90 7.58 0.216466E+09 355.69 13-SEP-07:10 20.18 12.26
October 0.149802E+10 6234.45 10-OCT-12:05 23.17 7.88 0.207962E+09 329.50 10-OCT-14:09 25.00 8.67
November 0.959338E+09 5358.72 07-NOV-13:55 22.00 7.34 0.198965E+09 304.99 09-NOV-13:09 20.00 8.90
December 0.426430E+09 3096.10 14-DEC-14:25 16.15 4.44 0.179042E+09 304.99 04-DEC-13:09 16.15 4.44
                     
Annual Sum or Average 0.148226E+11         0.248114E+10        
Minimum of Months 0.168728E+09 1845.27   13.90 4.44 0.170760E+09 304.99   14.00 4.44
Maximum of Months 0.285148E+10 6544.55   23.83 12.41 0.250194E+09 355.70   25.00 14.20



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 8313076.89 469.77 13-JAN-06:03 -5.0 -6.8 75312008.81 180.92 20-JAN-16:49 13.00 5.63
February 15936230.01 499.02 02-FEB-06:04 -9.2 -9.2 66851746.27 173.06 27-FEB-13:00 14.00 4.75
March 0.124526E+09 1340.88 15-MAR-10:04 15.17 4.28 88758334.40 181.54 31-MAR-10:20 15.00 6.25
April 0.122491E+09 1266.02 21-APR-08:54 12.00 5.98 79788135.20 181.07 11-APR-14:30 12.00 5.98
May 0.460406E+09 4952.51 11-MAY-07:02 10.17 5.46 98041411.74 205.21 17-MAY-07:10 19.50 10.18
June 0.185925E+10 4969.36 26-JUN-06:01 19.77 12.60 0.105110E+09 211.01 19-JUN-07:10 19.77 12.60
July 0.171250E+10 4944.48 05-JUL-07:02 17.33 10.79 95592479.64 211.00 19-JUL-07:10 21.33 14.20
August 0.198887E+10 4999.08 21-AUG-06:01 19.75 12.40 0.109875E+09 211.01 07-AUG-07:10 19.75 12.40
September 0.145382E+10 4900.04 05-SEP-07:02 14.68 7.70 94531226.59 211.01 06-SEP-07:10 17.25 13.03
October 0.396362E+09 2378.91 11-OCT-07:02 13.67 5.23 88776540.58 192.07 11-OCT-07:10 13.67 5.23
November 0.104029E+09 851.28 09-NOV-13:13 20.00 8.84 80818042.07 180.97 09-NOV-08:00 20.00 8.84
December 13570709.97 488.86 15-DEC-07:03 -2.8 -4.9 70657022.35 176.40 01-DEC-15:39 -2.8 -4.9
                     
Annual Sum or Average 0.826007E+10         0.105411E+10        
Minimum of Months 8313076.89 469.77   -9.2 -9.2 66851746.27 173.06   -2.8 -4.9
Maximum of Months 0.198887E+10 4999.08   20.00 12.60 0.109875E+09 211.01   21.33 14.20



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 9928254.79 878.23 03-JAN-06:04 -7.0 -7.0 0.168581E+09 278.78 20-JAN-15:00 18.00 7.49
February 2825326.66 929.40 10-FEB-06:04 -8.2 -9.1 0.150682E+09 245.37 17-FEB-16:40 13.33 6.60
March 42476853.97 830.29 29-MAR-05:04 -7.2 -8.2 0.193890E+09 304.99 16-MAR-12:30 -7.2 -8.2
April 34311933.18 841.30 17-APR-05:04 -8.0 -8.7 0.172682E+09 304.99 07-APR-15:00 -8.0 -8.7
May 0.377253E+09 1886.27 18-MAY-15:00 23.00 11.61 0.219962E+09 305.04 12-MAY-12:09 23.00 11.61
June 0.199815E+10 5805.39 15-JUN-07:02 16.28 11.51 0.239456E+09 355.77 12-JUN-07:10 16.28 11.51
July 0.197157E+10 5943.30 03-JUL-07:02 11.33 7.79 0.217854E+09 355.70 19-JUL-07:10 21.33 14.20
August 0.208592E+10 5857.36 21-AUG-06:01 19.75 12.40 0.250110E+09 355.70 07-AUG-07:10 19.75 12.40
September 0.152256E+10 5849.31 05-SEP-07:02 14.68 7.70 0.214914E+09 355.70 14-SEP-07:10 18.95 11.15
October 0.323217E+09 1976.48 11-OCT-15:13 25.33 9.18 0.197947E+09 305.00 03-OCT-14:30 25.33 9.18
November 67471778.43 1018.56 29-NOV-06:04 -10.2 -10.2 0.177943E+09 304.99 08-NOV-13:09 -10.2 -10.2
December 8377404.32 959.03 07-DEC-07:04 -7.8 -8.2 0.160000E+09 271.73 04-DEC-15:50 -7.8 -8.2
                     
Annual Sum or Average 0.844407E+10         0.236402E+10        
Minimum of Months 2825326.66 830.29   -10.2 -10.2 0.150682E+09 245.37   -10.2 -10.2
Maximum of Months 0.208592E+10 5943.30   25.33 12.40 0.250110E+09 355.77   25.33 14.20



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 26864914.43 896.85 20-JAN-16:22 15.00 6.47 0.105021E+09 181.27 27-JAN-15:50 9.17 5.36
February 14629621.37 638.16 17-FEB-16:33 13.33 6.60 93362178.97 180.92 27-FEB-16:00 13.00 4.60
March 0.111312E+09 1880.79 15-MAR-15:55 19.00 5.38 0.121210E+09 184.92 31-MAR-14:09 20.00 6.98
April 59550736.01 1463.57 07-APR-15:53 21.00 8.12 0.107404E+09 180.92 26-APR-15:00 12.00 8.07
May 0.353995E+09 2107.50 31-MAY-15:57 28.00 14.86 0.133551E+09 184.69 18-MAY-07:10 28.00 14.86
June 0.156614E+10 6187.67 26-JUN-06:01 19.77 12.60 0.143329E+09 211.00 19-JUN-07:10 19.77 12.60
July 0.143307E+10 6125.43 03-JUL-07:02 11.33 7.79 0.130054E+09 211.00 19-JUL-07:10 21.33 14.20
August 0.164380E+10 6251.28 21-AUG-06:01 19.75 12.40 0.149740E+09 211.00 11-AUG-07:10 19.75 12.40
September 0.128661E+10 6123.92 11-SEP-06:01 19.00 9.04 0.128925E+09 211.00 05-SEP-07:10 19.00 9.04
October 0.406244E+09 3054.23 11-OCT-15:54 24.00 8.61 0.122324E+09 193.35 11-OCT-07:10 24.00 8.61
November 0.113603E+09 1719.69 07-NOV-15:53 21.00 7.19 0.111821E+09 181.02 09-NOV-09:30 17.00 8.19
December 18119100.72 569.26 04-DEC-15:33 17.67 5.69 99168665.75 181.43 29-DEC-16:40 10.00 4.13
                     
Annual Sum or Average 0.703394E+10         0.144591E+10        
Minimum of Months 14629621.37 569.26   11.33 5.38 93362178.97 180.92   9.17 4.13
Maximum of Months 0.164380E+10 6251.28   28.00 14.86 0.149740E+09 211.00   28.00 14.86



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: ATTIC

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.00 0.00 01-JAN-00:05 0.50 -1.8 0.00 0.00 01-JAN-00:10 0.50 -1.8
February 0.00 0.00 01-FEB-00:10 -5.3 -5.3 0.00 0.00 01-FEB-00:10 -5.3 -5.3
March 0.00 0.00 01-MAR-00:10 -1.1 -1.1 0.00 0.00 01-MAR-00:10 -1.1 -1.1
April 0.00 0.00 01-APR-00:10 5.90 2.10 0.00 0.00 01-APR-00:10 5.90 2.10
May 0.00 0.00 01-MAY-00:10 5.43 4.75 0.00 0.00 01-MAY-00:10 5.43 4.75
June 0.00 0.00 01-JUN-00:10 15.88 11.26 0.00 0.00 01-JUN-00:10 15.88 11.26
July 0.00 0.00 01-JUL-00:10 22.27 10.91 0.00 0.00 01-JUL-00:10 22.27 10.91
August 0.00 0.00 01-AUG-00:10 18.93 15.43 0.00 0.00 01-AUG-00:10 18.93 15.43
September 0.00 0.00 01-SEP-00:05 18.18 10.64 0.00 0.00 01-SEP-00:10 18.18 10.64
October 0.00 0.00 01-OCT-00:10 10.30 8.03 0.00 0.00 01-OCT-00:10 10.30 8.03
November 0.00 0.00 01-NOV-00:10 -5.7 -5.7 0.00 0.00 01-NOV-00:10 -5.7 -5.7
December 0.00 0.00 01-DEC-00:05 2.77 -0.5 0.00 0.00 01-DEC-00:10 2.77 -0.5
                     
Annual Sum or Average 0.00         0.00        
Minimum of Months 0.00 0.00   -5.7 -5.7 0.00 0.00   -5.7 -5.7
Maximum of Months 0.00 0.00   22.27 15.43 0.00 0.00   22.27 15.43



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.159911E+09 8392.39 09-JAN-07:01 4.17
February 0.192886E+09 6833.91 16-FEB-07:01 -1.5
March 59669686.17 8375.31 06-MAR-07:01 2.00
April 52451807.95 7461.74 06-APR-07:02 2.50
May 10110168.86 4386.05 02-MAY-07:03 1.33
June 38441608.07 1204.03 26-JUN-17:01 37.70
July 27602157.84 874.00 24-JUL-17:01 32.50
August 35213469.38 1092.58 16-AUG-17:01 35.67
September 15284298.68 671.54 12-SEP-17:01 29.12
October 11558750.25 5406.12 31-OCT-06:01 -9.0
November 28799723.13 6430.01 01-NOV-06:01 -2.8
December 0.167512E+09 7231.01 12-DEC-07:01 -1.0
         
Annual Sum or Average 0.799440E+09      
Minimum of Months 10110168.86 671.54   -9.0
Maximum of Months 0.192886E+09 8392.39   37.70



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.923800E+09 9478.69 09-JAN-06:01 4.00
February 0.137895E+10 9732.23 07-FEB-06:01 -6.8
March 0.114168E+10 10072.77 06-MAR-06:01 1.17
April 0.941239E+09 10086.25 24-APR-05:01 -1.8
May 0.226235E+09 9077.43 02-MAY-06:01 0.17
June 57824754.69 993.33 26-JUN-17:11 37.70
July 47021341.51 735.05 14-JUL-17:23 31.50
August 47092748.25 888.58 16-AUG-17:11 35.33
September 27801648.94 3690.70 22-SEP-07:03 0.37
October 0.502984E+09 9131.53 31-OCT-06:01 -9.0
November 0.610120E+09 9897.96 01-NOV-05:01 -3.0
December 0.135854E+10 9792.24 11-DEC-06:01 -5.8
         
Annual Sum or Average 0.726329E+10      
Minimum of Months 27801648.94 735.05   -9.0
Maximum of Months 0.137895E+10 10086.25   37.70



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.961607E+09 7584.48 09-JAN-06:01 4.00
February 0.105323E+10 6987.64 15-FEB-06:02 -2.3
March 0.658027E+09 7643.55 06-MAR-06:01 1.17
April 0.434783E+09 7131.77 04-APR-05:01 -2.2
May 59552013.17 6861.06 02-MAY-06:01 0.17
June 34960981.08 670.83 26-JUN-17:11 37.70
July 29266176.94 523.46 14-JUL-17:23 31.50
August 32472340.59 613.86 16-AUG-17:11 35.33
September 19630858.35 430.69 12-SEP-17:22 28.55
October 0.238932E+09 6888.97 25-OCT-06:01 -1.5
November 0.420534E+09 6893.85 22-NOV-07:01 0.33
December 0.115440E+10 7434.39 27-DEC-06:02 0.50
         
Annual Sum or Average 0.509740E+10      
Minimum of Months 19630858.35 430.69   -2.3
Maximum of Months 0.115440E+10 7643.55   37.70



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.216911E+10 8948.30 02-JAN-06:01 -2.8
February 0.225682E+10 9041.13 14-FEB-06:01 -5.2
March 0.146986E+10 9428.09 05-MAR-08:51 -6.0
April 0.897890E+09 9067.02 24-APR-05:01 -1.8
May 0.133095E+09 8035.78 02-MAY-06:01 0.17
June 40086153.38 964.81 26-JUN-17:11 37.70
July 31315333.89 715.03 24-JUL-17:01 32.50
August 35644088.16 874.64 16-AUG-17:01 35.67
September 18768500.94 1971.90 22-SEP-07:03 0.37
October 0.390394E+09 8696.92 31-OCT-05:01 -8.2
November 0.934427E+09 8948.54 27-NOV-06:01 -6.8
December 0.230523E+10 9311.98 25-DEC-04:53 -6.0
         
Annual Sum or Average 0.106826E+11      
Minimum of Months 18768500.94 715.03   -8.2
Maximum of Months 0.230523E+10 9428.09   37.70



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.100162E+10 9725.80 09-JAN-06:01 4.00
February 0.109880E+10 8531.58 17-FEB-07:01 0.50
March 0.799507E+09 8833.13 06-MAR-06:01 1.17
April 0.546448E+09 8756.21 25-APR-06:01 2.83
May 0.126946E+09 8264.41 03-MAY-06:02 2.33
June 46861645.72 736.89 14-JUN-07:04 28.30
July 44409258.24 602.58 17-JUL-17:22 32.00
August 42182345.59 651.32 16-AUG-17:11 35.33
September 31548288.68 526.27 08-SEP-17:23 28.00
October 0.248805E+09 7670.31 25-OCT-06:01 -1.5
November 0.445739E+09 8112.13 22-NOV-07:01 0.33
December 0.119266E+10 8653.00 14-DEC-07:01 1.33
         
Annual Sum or Average 0.562552E+10      
Minimum of Months 31548288.68 526.27   -1.5
Maximum of Months 0.119266E+10 9725.80   35.33



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: ATTIC

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.00 0.00 01-JAN-00:05 0.50
February 0.00 0.00 01-FEB-00:10 -5.3
March 0.00 0.00 01-MAR-00:10 -1.1
April 0.00 0.00 01-APR-00:10 5.90
May 0.00 0.00 01-MAY-00:10 5.43
June 0.00 0.00 01-JUN-00:10 15.88
July 0.00 0.00 01-JUL-00:10 22.27
August 0.00 0.00 01-AUG-00:10 18.93
September 0.00 0.00 01-SEP-00:05 18.18
October 0.00 0.00 01-OCT-00:10 10.30
November 0.00 0.00 01-NOV-00:10 -5.7
December 0.00 0.00 01-DEC-00:05 2.77
         
Annual Sum or Average 0.00      
Minimum of Months 0.00 0.00   -5.7
Maximum of Months 0.00 0.00   22.27



Table of Contents

Report: ZoneElectricSummaryMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.114206E+10 948.30 02-JAN-08:09 0.129836E+10 1014.68 02-JAN-08:09
February 0.103251E+10 948.30 01-FEB-08:09 0.117388E+10 1014.68 01-FEB-08:09
March 0.120245E+10 948.30 01-MAR-08:09 0.137025E+10 1014.68 01-MAR-08:09
April 0.109548E+10 948.30 03-APR-07:10 0.124598E+10 1014.68 03-APR-07:10
May 0.117226E+10 948.30 01-MAY-07:10 0.133431E+10 1014.68 01-MAY-07:10
June 0.115587E+10 948.30 01-JUN-07:10 0.131568E+10 1014.68 01-JUN-07:10
July 0.111187E+10 948.30 03-JUL-07:10 0.126352E+10 1014.68 03-JUL-07:10
August 0.120245E+10 948.30 01-AUG-07:10 0.137025E+10 1014.68 01-AUG-07:10
September 0.109548E+10 948.30 01-SEP-07:10 0.124379E+10 1014.68 01-SEP-07:10
October 0.114206E+10 948.30 02-OCT-07:10 0.129946E+10 1014.68 02-OCT-07:10
November 0.112568E+10 948.30 01-NOV-07:10 0.128083E+10 1014.68 01-NOV-07:10
December 0.111187E+10 948.30 01-DEC-08:09 0.126242E+10 1014.68 01-DEC-08:09
             
Annual Sum or Average 0.135900E+11     0.154587E+11    
Minimum of Months 0.103251E+10 948.30   0.117388E+10 1014.68  
Maximum of Months 0.120245E+10 948.30   0.137025E+10 1014.68  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.748284E+09 718.87 02-JAN-16:49 0.984244E+09 769.19 02-JAN-08:09
February 0.674058E+09 712.81 06-FEB-16:00 0.889874E+09 769.19 01-FEB-08:09
March 0.770593E+09 694.38 21-MAR-07:10 0.103874E+10 769.19 01-MAR-08:09
April 0.698888E+09 685.53 03-APR-07:10 0.944536E+09 769.19 03-APR-07:10
May 0.736288E+09 629.03 19-MAY-07:10 0.101149E+10 769.19 01-MAY-07:10
June 0.724026E+09 642.43 16-JUN-07:10 0.997370E+09 769.19 01-JUN-07:10
July 0.699625E+09 634.33 28-JUL-07:10 0.957827E+09 769.19 03-JUL-07:10
August 0.760054E+09 657.35 28-AUG-15:00 0.103874E+10 769.19 01-AUG-07:10
September 0.697435E+09 656.37 21-SEP-15:00 0.942874E+09 769.19 01-SEP-07:10
October 0.743336E+09 704.37 30-OCT-07:10 0.985075E+09 769.19 02-OCT-07:10
November 0.741811E+09 718.87 06-NOV-16:49 0.970953E+09 769.19 01-NOV-07:10
December 0.735673E+09 718.87 01-DEC-16:30 0.956997E+09 769.19 01-DEC-08:09
             
Annual Sum or Average 0.873007E+10     0.117187E+11    
Minimum of Months 0.674058E+09 629.03   0.889874E+09 769.19  
Maximum of Months 0.770593E+09 718.87   0.103874E+10 769.19  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.464660E+09 426.44 02-JAN-16:49 0.583867E+09 456.29 02-JAN-08:09
February 0.417279E+09 423.16 06-FEB-16:00 0.527885E+09 456.29 01-FEB-08:09
March 0.471859E+09 412.01 21-MAR-07:10 0.616194E+09 456.29 01-MAR-08:09
April 0.421352E+09 406.17 03-APR-07:10 0.560311E+09 456.29 03-APR-07:10
May 0.442194E+09 385.59 12-MAY-13:30 0.600030E+09 456.29 01-MAY-07:10
June 0.435570E+09 374.74 16-JUN-07:10 0.591653E+09 456.29 01-JUN-07:10
July 0.419461E+09 379.54 12-JUL-15:00 0.568196E+09 456.29 03-JUL-07:10
August 0.460495E+09 396.41 28-AUG-15:00 0.616194E+09 456.29 01-AUG-07:10
September 0.422398E+09 398.39 08-SEP-15:00 0.559325E+09 456.29 01-SEP-07:10
October 0.455277E+09 418.13 30-OCT-07:10 0.584359E+09 456.29 02-OCT-07:10
November 0.458215E+09 426.44 06-NOV-16:49 0.575982E+09 456.29 01-NOV-07:10
December 0.455462E+09 426.44 01-DEC-16:30 0.567703E+09 456.29 01-DEC-08:09
             
Annual Sum or Average 0.532422E+10     0.695170E+10    
Minimum of Months 0.417279E+09 374.74   0.527885E+09 456.29  
Maximum of Months 0.471859E+09 426.44   0.616194E+09 456.29  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.820118E+09 718.87 02-JAN-16:49 0.984244E+09 769.19 02-JAN-08:09
February 0.731954E+09 713.33 06-FEB-16:00 0.889874E+09 769.19 01-FEB-08:09
March 0.820097E+09 696.89 21-MAR-07:10 0.103874E+10 769.19 01-MAR-08:09
April 0.716158E+09 688.46 03-APR-07:10 0.944536E+09 769.19 03-APR-07:10
May 0.735861E+09 645.53 12-MAY-13:30 0.101149E+10 769.19 01-MAY-07:10
June 0.722920E+09 643.97 16-JUN-07:10 0.997370E+09 769.19 01-JUN-07:10
July 0.699214E+09 635.50 28-JUL-07:10 0.957827E+09 769.19 03-JUL-07:10
August 0.780036E+09 663.36 28-AUG-15:00 0.103874E+10 769.19 01-AUG-07:10
September 0.730699E+09 666.27 21-SEP-15:00 0.942874E+09 769.19 01-SEP-07:10
October 0.793317E+09 706.08 30-OCT-07:10 0.985075E+09 769.19 02-OCT-07:10
November 0.803450E+09 718.87 06-NOV-16:49 0.970953E+09 769.19 01-NOV-07:10
December 0.799565E+09 718.87 01-DEC-16:30 0.956997E+09 769.19 01-DEC-08:09
             
Annual Sum or Average 0.915339E+10     0.117187E+11    
Minimum of Months 0.699214E+09 635.50   0.889874E+09 769.19  
Maximum of Months 0.820118E+09 718.87   0.103874E+10 769.19  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.463827E+09 426.44 02-JAN-16:49 0.583867E+09 456.29 02-JAN-08:09
February 0.414679E+09 423.00 06-FEB-16:00 0.527885E+09 456.29 01-FEB-08:09
March 0.472692E+09 413.81 21-MAR-07:10 0.616194E+09 456.29 01-MAR-08:09
April 0.422531E+09 409.53 03-APR-07:10 0.560311E+09 456.29 03-APR-07:10
May 0.443183E+09 389.80 01-MAY-07:19 0.600030E+09 456.29 01-MAY-07:10
June 0.435887E+09 389.58 16-JUN-07:10 0.591653E+09 456.29 01-JUN-07:10
July 0.421085E+09 390.96 12-JUL-07:10 0.568196E+09 456.29 03-JUL-07:10
August 0.460341E+09 393.53 21-AUG-07:10 0.616194E+09 456.29 01-AUG-07:10
September 0.425232E+09 402.52 25-SEP-07:10 0.559325E+09 456.29 01-SEP-07:10
October 0.452886E+09 418.87 30-OCT-07:10 0.584359E+09 456.29 02-OCT-07:10
November 0.455477E+09 426.44 06-NOV-16:49 0.575982E+09 456.29 01-NOV-07:10
December 0.452114E+09 426.44 01-DEC-16:30 0.567703E+09 456.29 01-DEC-08:09
             
Annual Sum or Average 0.531993E+10     0.695170E+10    
Minimum of Months 0.414679E+09 389.58   0.527885E+09 456.29  
Maximum of Months 0.472692E+09 426.44   0.616194E+09 456.29  



Table of Contents

Report: SpaceGainsMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 0.711734E+09 0.114206E+10 0.129836E+10 0.00 0.00 0.00 0.00 0.00 0.00
February 0.643949E+09 0.103251E+10 0.117388E+10 0.00 0.00 0.00 0.00 0.00 0.00
March 0.779518E+09 0.120245E+10 0.137025E+10 0.00 0.00 0.00 0.00 0.00 0.00
April 0.677841E+09 0.109548E+10 0.124598E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.745626E+09 0.117226E+10 0.133431E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.745626E+09 0.115587E+10 0.131568E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.677841E+09 0.111187E+10 0.126352E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.779518E+09 0.120245E+10 0.137025E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.677841E+09 0.109548E+10 0.124379E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.711734E+09 0.114206E+10 0.129946E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 0.711734E+09 0.112568E+10 0.128083E+10 0.00 0.00 0.00 0.00 0.00 0.00
December 0.677841E+09 0.111187E+10 0.126242E+10 0.00 0.00 0.00 0.00 0.00 0.00
                   
Annual Sum or Average 0.854080E+10 0.135900E+11 0.154587E+11 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.643949E+09 0.103251E+10 0.117388E+10 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.779518E+09 0.120245E+10 0.137025E+10 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SpaceGainsMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.539540E+09 0.748284E+09 0.984244E+09 0.00 0.00 0.00 0.00 0.00 0.107228E+10
February 0.488155E+09 0.674058E+09 0.889874E+09 0.00 0.00 0.00 0.00 0.00 0.117582E+10
March 0.590925E+09 0.770593E+09 0.103874E+10 0.00 0.00 0.00 0.00 1329.95 0.105985E+10
April 0.513848E+09 0.698888E+09 0.944536E+09 0.00 0.00 0.00 0.00 0.00 0.871651E+09
May 0.565233E+09 0.736288E+09 0.101149E+10 0.00 0.00 0.00 0.00 11705669.25 0.521503E+09
June 0.565233E+09 0.724026E+09 0.997370E+09 0.00 0.00 0.00 0.00 0.159066E+09 0.191946E+09
July 0.513848E+09 0.699625E+09 0.957827E+09 0.00 0.00 0.00 0.00 0.129866E+09 0.192426E+09
August 0.590925E+09 0.760054E+09 0.103874E+10 0.00 0.00 0.00 0.00 0.138314E+09 0.243448E+09
September 0.513848E+09 0.697435E+09 0.942874E+09 0.00 0.00 0.00 0.00 59895916.49 0.363728E+09
October 0.539540E+09 0.743336E+09 0.985075E+09 0.00 0.00 0.00 0.00 1378890.99 0.967463E+09
November 0.539540E+09 0.741811E+09 0.970953E+09 0.00 0.00 0.00 0.00 0.00 0.107235E+10
December 0.513848E+09 0.735673E+09 0.956997E+09 0.00 0.00 0.00 0.00 0.00 0.142110E+10
                   
Annual Sum or Average 0.647448E+10 0.873007E+10 0.117187E+11 0.00 0.00 0.00 0.00 0.500229E+09 0.915356E+10
Minimum of Months 0.488155E+09 0.674058E+09 0.889874E+09 0.00 0.00 0.00 0.00 0.00 0.191946E+09
Maximum of Months 0.590925E+09 0.770593E+09 0.103874E+10 0.00 0.00 0.00 0.00 0.159066E+09 0.142110E+10



Table of Contents

Report: SpaceGainsMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.234287E+09 0.464660E+09 0.583867E+09 0.00 0.00 0.00 0.00 0.00 0.130243E+09
February 0.211974E+09 0.417279E+09 0.527885E+09 0.00 0.00 0.00 0.00 0.00 0.209526E+09
March 0.256600E+09 0.471859E+09 0.616194E+09 0.00 0.00 0.00 0.00 86.22 0.223120E+09
April 0.223130E+09 0.421352E+09 0.560311E+09 0.00 0.00 0.00 0.00 0.00 0.232456E+09
May 0.245443E+09 0.442194E+09 0.600030E+09 0.00 0.00 0.00 0.00 509330.61 0.129822E+09
June 0.245443E+09 0.435570E+09 0.591653E+09 0.00 0.00 0.00 0.00 9032877.30 68479138.51
July 0.223130E+09 0.419461E+09 0.568196E+09 0.00 0.00 0.00 0.00 8590487.36 72027983.87
August 0.256600E+09 0.460495E+09 0.616194E+09 0.00 0.00 0.00 0.00 5669949.86 72364112.99
September 0.223130E+09 0.422398E+09 0.559325E+09 0.00 0.00 0.00 0.00 2343773.28 0.105121E+09
October 0.234287E+09 0.455277E+09 0.584359E+09 0.00 0.00 0.00 0.00 78833.39 0.194401E+09
November 0.234287E+09 0.458215E+09 0.575982E+09 0.00 0.00 0.00 0.00 0.00 0.158564E+09
December 0.223130E+09 0.455462E+09 0.567703E+09 0.00 0.00 0.00 0.00 387.96 0.294848E+09
                   
Annual Sum or Average 0.281144E+10 0.532422E+10 0.695170E+10 0.00 0.00 0.00 0.00 26225725.97 0.189097E+10
Minimum of Months 0.211974E+09 0.417279E+09 0.527885E+09 0.00 0.00 0.00 0.00 0.00 68479138.51
Maximum of Months 0.256600E+09 0.471859E+09 0.616194E+09 0.00 0.00 0.00 0.00 9032877.30 0.294848E+09



Table of Contents

Report: SpaceGainsMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.539540E+09 0.820118E+09 0.984244E+09 0.00 0.00 0.00 0.00 0.00 0.190759E+09
February 0.488155E+09 0.731954E+09 0.889874E+09 0.00 0.00 0.00 0.00 7558.15 0.305512E+09
March 0.590925E+09 0.820097E+09 0.103874E+10 0.00 0.00 0.00 0.00 129.33 0.323680E+09
April 0.513848E+09 0.716158E+09 0.944536E+09 0.00 0.00 0.00 0.00 0.00 0.336699E+09
May 0.565233E+09 0.735861E+09 0.101149E+10 0.00 0.00 0.00 0.00 878069.56 0.186566E+09
June 0.565233E+09 0.722920E+09 0.997370E+09 0.00 0.00 0.00 0.00 15287794.41 96840294.72
July 0.513848E+09 0.699214E+09 0.957827E+09 0.00 0.00 0.00 0.00 15647576.97 98512959.99
August 0.590925E+09 0.780036E+09 0.103874E+10 0.00 0.00 0.00 0.00 9338744.86 99024615.69
September 0.513848E+09 0.730699E+09 0.942874E+09 0.00 0.00 0.00 0.00 4418981.76 0.144479E+09
October 0.539540E+09 0.793317E+09 0.985075E+09 0.00 0.00 0.00 0.00 118249.67 0.276952E+09
November 0.539540E+09 0.803450E+09 0.970953E+09 0.00 0.00 0.00 0.00 35245.54 0.230321E+09
December 0.513848E+09 0.799565E+09 0.956997E+09 0.00 0.00 0.00 0.00 54844.10 0.434708E+09
                   
Annual Sum or Average 0.647448E+10 0.915339E+10 0.117187E+11 0.00 0.00 0.00 0.00 45787194.34 0.272406E+10
Minimum of Months 0.488155E+09 0.699214E+09 0.889874E+09 0.00 0.00 0.00 0.00 0.00 96840294.72
Maximum of Months 0.590925E+09 0.820118E+09 0.103874E+10 0.00 0.00 0.00 0.00 15647576.97 0.434708E+09



Table of Contents

Report: SpaceGainsMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.320062E+09 0.463827E+09 0.583867E+09 0.00 0.00 0.00 0.00 0.00 0.131853E+09
February 0.289580E+09 0.414679E+09 0.527885E+09 0.00 0.00 0.00 0.00 0.00 0.211810E+09
March 0.350544E+09 0.472692E+09 0.616194E+09 0.00 0.00 0.00 0.00 86.22 0.226028E+09
April 0.304821E+09 0.422531E+09 0.560311E+09 0.00 0.00 0.00 0.00 0.00 0.235145E+09
May 0.335303E+09 0.443183E+09 0.600030E+09 0.00 0.00 0.00 0.00 549467.45 0.132497E+09
June 0.335303E+09 0.435887E+09 0.591653E+09 0.00 0.00 0.00 0.00 8888658.18 73725764.51
July 0.304821E+09 0.421085E+09 0.568196E+09 0.00 0.00 0.00 0.00 9061679.33 72280298.61
August 0.350544E+09 0.460341E+09 0.616194E+09 0.00 0.00 0.00 0.00 5604098.20 75750941.32
September 0.304821E+09 0.425232E+09 0.559325E+09 0.00 0.00 0.00 0.00 2517754.16 0.107575E+09
October 0.320062E+09 0.452886E+09 0.584359E+09 0.00 0.00 0.00 0.00 78833.02 0.196869E+09
November 0.320062E+09 0.455477E+09 0.575982E+09 0.00 0.00 0.00 0.00 0.00 0.160918E+09
December 0.304821E+09 0.452114E+09 0.567703E+09 0.00 0.00 0.00 0.00 628.72 0.297346E+09
                   
Annual Sum or Average 0.384075E+10 0.531993E+10 0.695170E+10 0.00 0.00 0.00 0.00 26701205.28 0.192180E+10
Minimum of Months 0.289580E+09 0.414679E+09 0.527885E+09 0.00 0.00 0.00 0.00 0.00 72280298.61
Maximum of Months 0.350544E+09 0.472692E+09 0.616194E+09 0.00 0.00 0.00 0.00 9061679.33 0.297346E+09



Table of Contents

Report: SpaceGainsMonthly

For: ATTIC

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [] ZONE LIGHTS TOTAL HEATING ENERGY [] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.102962E+10 0.186668E+10
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.832678E+09 0.227876E+10
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.754417E+09 0.293975E+10
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.526810E+09 0.303852E+10
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.529514E+09 0.384781E+10
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.617674E+09 0.422712E+10
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.562631E+09 0.380728E+10
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.626341E+09 0.389782E+10
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.837371E+09 0.295913E+10
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.870938E+09 0.247598E+10
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.865756E+09 0.202458E+10
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.104647E+10 0.145910E+10
                   
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.910022E+10 0.348225E+11
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.526810E+09 0.145910E+10
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.104647E+10 0.422712E+10



Table of Contents

Report: PeakSpaceGainsMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 966.54 02-JAN-08:09 948.30 02-JAN-08:09 1014.68 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 0.00
February 966.54 01-FEB-08:09 948.30 01-FEB-08:09 1014.68 01-FEB-08:09 0.00 0.00 0.00 0.00 0.00 0.00
March 966.54 01-MAR-08:09 948.30 01-MAR-08:09 1014.68 01-MAR-08:09 0.00 0.00 0.00 0.00 0.00 0.00
April 966.54 03-APR-07:10 948.30 03-APR-07:10 1014.68 03-APR-07:10 0.00 0.00 0.00 0.00 0.00 0.00
May 966.54 01-MAY-07:10 948.30 01-MAY-07:10 1014.68 01-MAY-07:10 0.00 0.00 0.00 0.00 0.00 0.00
June 966.54 01-JUN-07:10 948.30 01-JUN-07:10 1014.68 01-JUN-07:10 0.00 0.00 0.00 0.00 0.00 0.00
July 966.54 03-JUL-07:10 948.30 03-JUL-07:10 1014.68 03-JUL-07:10 0.00 0.00 0.00 0.00 0.00 0.00
August 966.54 01-AUG-07:10 948.30 01-AUG-07:10 1014.68 01-AUG-07:10 0.00 0.00 0.00 0.00 0.00 0.00
September 966.54 01-SEP-07:10 948.30 01-SEP-07:10 1014.68 01-SEP-07:10 0.00 0.00 0.00 0.00 0.00 0.00
October 966.54 02-OCT-07:10 948.30 02-OCT-07:10 1014.68 02-OCT-07:10 0.00 0.00 0.00 0.00 0.00 0.00
November 966.54 01-NOV-07:10 948.30 01-NOV-07:10 1014.68 01-NOV-07:10 0.00 0.00 0.00 0.00 0.00 0.00
December 966.54 01-DEC-08:09 948.30 01-DEC-08:09 1014.68 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average             0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 966.54   948.30   1014.68   0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 966.54   948.30   1014.68   0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: PeakSpaceGainsMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 732.70 02-JAN-08:09 718.87 02-JAN-16:49 769.19 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 5443.31 05-JAN-17:53
February 732.70 01-FEB-08:09 712.81 06-FEB-16:00 769.19 01-FEB-08:09 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 4272.94 02-FEB-07:10
March 732.70 01-MAR-08:09 694.38 21-MAR-07:10 769.19 01-MAR-08:09 0.00 0.00 0.00 0.00 2.22 14-MAR-13:00 4094.29 02-MAR-07:10
April 732.70 03-APR-07:10 685.53 03-APR-07:10 769.19 03-APR-07:10 0.00 0.00 0.00 0.00 0.00 01-APR-00:10 3903.96 17-APR-06:10
May 732.70 01-MAY-07:10 629.03 19-MAY-07:10 769.19 01-MAY-07:10 0.00 0.00 0.00 0.00 510.14 31-MAY-16:10 2794.29 02-MAY-06:10
June 732.70 01-JUN-07:10 642.43 16-JUN-07:10 769.19 01-JUN-07:10 0.00 0.00 0.00 0.00 1788.68 26-JUN-16:05 1805.74 09-JUN-06:03
July 732.70 03-JUL-07:10 634.33 28-JUL-07:10 769.19 03-JUL-07:10 0.00 0.00 0.00 0.00 1442.53 17-JUL-11:55 1837.72 03-JUL-06:02
August 732.70 01-AUG-07:10 657.35 28-AUG-15:00 769.19 01-AUG-07:10 0.00 0.00 0.00 0.00 1589.76 16-AUG-16:03 1676.14 17-AUG-06:03
September 732.70 01-SEP-07:10 656.37 21-SEP-15:00 769.19 01-SEP-07:10 0.00 0.00 0.00 0.00 885.34 12-SEP-16:10 3250.81 21-SEP-16:02
October 732.70 02-OCT-07:10 704.37 30-OCT-07:10 769.19 02-OCT-07:10 0.00 0.00 0.00 0.00 143.49 10-OCT-17:00 4334.94 30-OCT-06:10
November 732.70 01-NOV-07:10 718.87 06-NOV-16:49 769.19 01-NOV-07:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:10 4946.68 29-NOV-17:53
December 732.70 01-DEC-08:09 718.87 01-DEC-16:30 769.19 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 01-DEC-00:05 6488.29 21-DEC-17:02
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 732.70   629.03   769.19   0.00 0.00 0.00 0.00 0.00   1676.14  
Maximum of Months 732.70   718.87   769.19   0.00 0.00 0.00 0.00 1788.68   6488.29  



Table of Contents

Report: PeakSpaceGainsMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 434.65 02-JAN-08:09 426.44 02-JAN-16:49 456.29 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 220.37 12-JAN-07:00
February 434.65 01-FEB-08:09 423.16 06-FEB-16:00 456.29 01-FEB-08:09 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 329.73 24-FEB-19:03
March 434.65 01-MAR-08:09 412.01 21-MAR-07:10 456.29 01-MAR-08:09 0.00 0.00 0.00 0.00 0.14 14-MAR-13:00 650.63 19-MAR-06:56
April 434.65 03-APR-07:10 406.17 03-APR-07:10 456.29 03-APR-07:10 0.00 0.00 0.00 0.00 0.00 01-APR-00:10 394.61 15-APR-05:00
May 434.65 01-MAY-07:10 385.59 12-MAY-13:30 456.29 01-MAY-07:10 0.00 0.00 0.00 0.00 12.89 17-MAY-14:43 248.82 02-MAY-05:55
June 434.65 01-JUN-07:10 374.74 16-JUN-07:10 456.29 01-JUN-07:10 0.00 0.00 0.00 0.00 53.00 26-JUN-18:53 158.09 08-JUN-23:00
July 434.65 03-JUL-07:10 379.54 12-JUL-15:00 456.29 03-JUL-07:10 0.00 0.00 0.00 0.00 77.88 16-JUL-12:00 170.12 03-JUL-03:00
August 434.65 01-AUG-07:10 396.41 28-AUG-15:00 456.29 01-AUG-07:10 0.00 0.00 0.00 0.00 39.71 02-AUG-15:53 214.90 27-AUG-17:55
September 434.65 01-SEP-07:10 398.39 08-SEP-15:00 456.29 01-SEP-07:10 0.00 0.00 0.00 0.00 19.75 10-SEP-12:55 171.95 22-SEP-02:00
October 434.65 02-OCT-07:10 418.13 30-OCT-07:10 456.29 02-OCT-07:10 0.00 0.00 0.00 0.00 5.98 11-OCT-14:00 353.14 29-OCT-09:00
November 434.65 01-NOV-07:10 426.44 06-NOV-16:49 456.29 01-NOV-07:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:10 326.50 30-NOV-06:04
December 434.65 01-DEC-08:09 426.44 01-DEC-16:30 456.29 01-DEC-08:09 0.00 0.00 0.00 0.00 0.47 02-DEC-14:55 641.18 21-DEC-19:01
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 434.65   374.74   456.29   0.00 0.00 0.00 0.00 0.00   158.09  
Maximum of Months 434.65   426.44   456.29   0.00 0.00 0.00 0.00 77.88   650.63  



Table of Contents

Report: PeakSpaceGainsMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 732.70 02-JAN-08:09 718.87 02-JAN-16:49 769.19 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 330.55 12-JAN-07:00
February 732.70 01-FEB-08:09 713.33 06-FEB-16:00 769.19 01-FEB-08:09 0.00 0.00 0.00 0.00 1.67 18-FEB-12:55 491.81 24-FEB-19:03
March 732.70 01-MAR-08:09 696.89 21-MAR-07:10 769.19 01-MAR-08:09 0.00 0.00 0.00 0.00 0.22 14-MAR-13:00 963.81 19-MAR-06:52
April 732.70 03-APR-07:10 688.46 03-APR-07:10 769.19 03-APR-07:10 0.00 0.00 0.00 0.00 0.00 01-APR-00:10 589.71 15-APR-05:00
May 732.70 01-MAY-07:10 645.53 12-MAY-13:30 769.19 01-MAY-07:10 0.00 0.00 0.00 0.00 19.34 17-MAY-14:43 373.23 02-MAY-05:55
June 732.70 01-JUN-07:10 643.97 16-JUN-07:10 769.19 01-JUN-07:10 0.00 0.00 0.00 0.00 80.96 26-JUN-18:53 233.52 08-JUN-23:00
July 732.70 03-JUL-07:10 635.50 28-JUL-07:10 769.19 03-JUL-07:10 0.00 0.00 0.00 0.00 130.05 16-JUL-12:00 242.68 03-JUL-03:00
August 732.70 01-AUG-07:10 663.36 28-AUG-15:00 769.19 01-AUG-07:10 0.00 0.00 0.00 0.00 59.56 02-AUG-15:53 301.34 27-AUG-17:55
September 732.70 01-SEP-07:10 666.27 21-SEP-15:00 769.19 01-SEP-07:10 0.00 0.00 0.00 0.00 42.80 10-SEP-12:55 257.44 22-SEP-02:00
October 732.70 02-OCT-07:10 706.08 30-OCT-07:10 769.19 02-OCT-07:10 0.00 0.00 0.00 0.00 8.98 11-OCT-14:00 514.61 29-OCT-09:00
November 732.70 01-NOV-07:10 718.87 06-NOV-16:49 769.19 01-NOV-07:10 0.00 0.00 0.00 0.00 4.98 05-NOV-14:53 495.56 01-NOV-04:00
December 732.70 01-DEC-08:09 718.87 01-DEC-16:30 769.19 01-DEC-08:09 0.00 0.00 0.00 0.00 5.32 02-DEC-14:55 962.83 21-DEC-19:01
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 732.70   635.50   769.19   0.00 0.00 0.00 0.00 0.00   233.52  
Maximum of Months 732.70   718.87   769.19   0.00 0.00 0.00 0.00 130.05   963.81  



Table of Contents

Report: PeakSpaceGainsMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 434.65 02-JAN-08:09 426.44 02-JAN-16:49 456.29 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 220.37 12-JAN-07:00
February 434.65 01-FEB-08:09 423.00 06-FEB-16:00 456.29 01-FEB-08:09 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 337.45 24-FEB-19:03
March 434.65 01-MAR-08:09 413.81 21-MAR-07:10 456.29 01-MAR-08:09 0.00 0.00 0.00 0.00 0.14 14-MAR-13:00 650.63 19-MAR-06:58
April 434.65 03-APR-07:10 409.53 03-APR-07:10 456.29 03-APR-07:10 0.00 0.00 0.00 0.00 0.00 01-APR-00:10 391.03 15-APR-05:00
May 434.65 01-MAY-07:10 389.80 01-MAY-07:19 456.29 01-MAY-07:10 0.00 0.00 0.00 0.00 12.89 17-MAY-14:43 254.46 18-MAY-18:03
June 434.65 01-JUN-07:10 389.58 16-JUN-07:10 456.29 01-JUN-07:10 0.00 0.00 0.00 0.00 48.38 26-JUN-18:44 176.11 08-JUN-21:55
July 434.65 03-JUL-07:10 390.96 12-JUL-07:10 456.29 03-JUL-07:10 0.00 0.00 0.00 0.00 79.97 16-JUL-12:00 173.49 03-JUL-03:00
August 434.65 01-AUG-07:10 393.53 21-AUG-07:10 456.29 01-AUG-07:10 0.00 0.00 0.00 0.00 39.71 02-AUG-15:53 228.40 27-AUG-17:55
September 434.65 01-SEP-07:10 402.52 25-SEP-07:10 456.29 01-SEP-07:10 0.00 0.00 0.00 0.00 25.77 10-SEP-12:55 171.46 22-SEP-02:00
October 434.65 02-OCT-07:10 418.87 30-OCT-07:10 456.29 02-OCT-07:10 0.00 0.00 0.00 0.00 5.98 11-OCT-14:00 349.23 29-OCT-09:00
November 434.65 01-NOV-07:10 426.44 06-NOV-16:49 456.29 01-NOV-07:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:10 328.12 30-NOV-06:04
December 434.65 01-DEC-08:09 426.44 01-DEC-16:30 456.29 01-DEC-08:09 0.00 0.00 0.00 0.00 0.38 02-DEC-13:00 641.93 21-DEC-19:01
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 434.65   389.58   456.29   0.00 0.00 0.00 0.00 0.00   171.46  
Maximum of Months 434.65   426.44   456.29   0.00 0.00 0.00 0.00 79.97   650.63  



Table of Contents

Report: PeakSpaceGainsMonthly

For: ATTIC

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [] ZONE LIGHTS TOTAL HEATING ENERGY [] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2120.83 14-JAN-08:51 4288.03 31-JAN-12:50
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1317.70 07-FEB-08:62 5163.37 12-FEB-13:10
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1369.16 23-MAR-06:53 5838.92 26-MAR-12:00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1493.78 07-APR-03:55 6412.69 24-APR-12:30
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1232.80 13-MAY-05:33 5983.42 09-MAY-12:20
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1485.23 06-JUN-22:00 5657.50 22-JUN-12:00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1080.92 01-JUL-05:33 5825.67 03-JUL-12:20
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1192.47 15-AUG-03:00 5602.90 13-AUG-11:50
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1329.17 28-SEP-06:53 5046.41 20-SEP-12:30
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1468.57 14-OCT-07:22 5017.18 04-OCT-13:10
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1449.49 30-NOV-07:53 4711.33 12-NOV-12:30
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2105.47 23-DEC-08:51 3980.21 21-DEC-13:10
                       
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00        
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1080.92   3980.21  
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2120.83   6412.69  



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 1771.02 05-JAN-06:01 744.23 1696.42 3551.37 0.00 0.00 0.00 0.00 0.00 0.00
February 1555.47 02-FEB-07:04 1420.81 3097.74 3551.37 0.00 0.00 0.00 0.00 0.00 0.00
March 2211.93 15-MAR-15:55 3866.15 3793.20 4058.71 0.00 0.00 0.00 0.00 0.00 0.00
April 1731.56 21-APR-14:22 8698.85 8534.70 9132.09 0.00 0.00 0.00 0.00 0.00 0.00
May 6048.97 17-MAY-07:01 6765.77 6638.10 7102.74 0.00 0.00 0.00 0.00 0.00 0.00
June 6335.32 09-JUN-07:02 4832.69 4741.50 5073.39 0.00 0.00 0.00 0.00 0.00 0.00
July 6606.36 03-JUL-06:02 1014.87 2212.67 2536.69 0.00 0.00 0.00 0.00 0.00 0.00
August 6359.20 15-AUG-06:03 811.89 1770.14 2029.35 0.00 0.00 0.00 0.00 0.00 0.00
September 6516.33 05-SEP-06:02 1217.84 2655.21 3044.03 0.00 0.00 0.00 0.00 0.00 0.00
October 6489.16 02-OCT-07:03 3866.15 3793.20 4058.71 0.00 0.00 0.00 0.00 0.00 0.00
November 1933.36 09-NOV-14:18 3866.15 3793.20 4058.71 0.00 0.00 0.00 0.00 0.00 0.00
December 1970.80 22-DEC-06:02 637.92 1454.08 3044.03 0.00 0.00 0.00 0.00 0.00 0.00
                       
Annual Sum or Average           0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 1555.47   637.92 1454.08 2029.35 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 6606.36   8698.85 8534.70 9132.09 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 3755.80 20-JAN-14:37 2198.10 1639.25 2307.57 0.00 0.00 0.00 0.00 0.00 70.99
February 2837.04 27-FEB-14:15 1465.40 1092.83 1538.38 0.00 0.00 0.00 0.00 0.00 260.63
March 4178.73 15-MAR-14:00 1465.40 1092.83 1538.38 0.00 0.00 0.00 0.00 0.00 58.63
April 1845.27 21-APR-13:30 732.70 546.42 769.19 0.00 0.00 0.00 0.00 0.00 181.84
May 2256.17 18-MAY-14:10 732.70 546.42 769.19 0.00 0.00 0.00 0.00 0.00 1.22
June 6296.51 26-JUN-07:01 5128.89 4027.10 5384.34 0.00 0.00 0.00 0.00 0.00 59.57
July 6264.29 17-JUL-06:01 1077.07 2061.18 2692.17 0.00 0.00 0.00 0.00 0.00 539.29
August 6496.72 21-AUG-06:01 1077.07 2112.33 2692.17 0.00 0.00 0.00 0.00 0.00 861.81
September 6544.55 05-SEP-06:02 923.20 1954.93 2307.57 0.00 0.00 0.00 0.00 0.00 1606.04
October 6234.45 10-OCT-12:05 1465.40 1092.83 1538.38 0.00 0.00 0.00 0.00 0.00 18.68
November 5358.72 07-NOV-13:55 1465.40 1092.83 1538.38 0.00 0.00 0.00 0.00 0.00 39.99
December 3096.10 14-DEC-14:25 1465.40 1092.83 1538.38 0.00 0.00 0.00 0.00 0.00 156.53
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 1845.27   732.70 546.42 769.19 0.00 0.00 0.00 0.00 0.00 1.22
Maximum of Months 6544.55   5128.89 4027.10 5384.34 0.00 0.00 0.00 0.00 0.00 1606.04



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 469.77 13-JAN-06:03 286.87 653.89 1368.88 0.00 0.00 0.00 0.00 0.00 74.11
February 499.02 02-FEB-06:04 382.49 871.85 1825.18 0.00 0.00 0.00 0.00 0.00 137.84
March 1340.88 15-MAR-10:04 2173.23 1620.70 2281.47 0.00 0.00 0.00 0.00 0.00 5.10
April 1266.02 21-APR-08:54 2173.23 1620.70 2281.47 0.00 0.00 0.00 0.00 0.00 21.22
May 4952.51 11-MAY-07:02 2607.88 1944.84 2737.76 0.00 0.00 0.00 0.00 0.00 34.67
June 4969.36 26-JUN-06:01 638.93 1058.85 1597.03 0.00 0.00 0.00 0.00 0.00 10.83
July 4944.48 05-JUL-07:02 2607.88 1944.84 2737.76 0.00 0.00 0.00 0.00 0.00 11.77
August 4999.08 21-AUG-06:01 638.93 1123.62 1597.03 0.00 0.00 0.00 0.00 0.00 12.04
September 4900.04 05-SEP-07:02 2173.23 1730.61 2281.47 0.00 0.00 0.00 0.00 0.00 17.52
October 2378.91 11-OCT-07:02 2173.23 1620.70 2281.47 0.00 0.00 0.00 0.00 0.00 18.77
November 851.28 09-NOV-13:13 1303.94 972.42 1368.88 0.00 0.00 0.00 0.00 0.00 1.10
December 488.86 15-DEC-07:03 547.65 1194.03 1368.88 0.00 0.00 0.00 0.00 0.00 35.93
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 469.77   286.87 653.89 1368.88 0.00 0.00 0.00 0.00 0.00 1.10
Maximum of Months 4999.08   2607.88 1944.84 2737.76 0.00 0.00 0.00 0.00 0.00 137.84



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 878.23 03-JAN-06:04 644.77 1469.71 3076.76 0.00 0.00 0.00 0.00 0.00 203.90
February 929.40 10-FEB-06:04 644.77 1469.71 3076.76 0.00 0.00 0.00 0.00 0.00 277.53
March 830.29 29-MAR-05:04 564.18 1286.00 2692.17 0.00 0.00 0.00 0.00 0.00 226.52
April 841.30 17-APR-05:04 725.37 1653.43 3461.36 0.00 0.00 0.00 0.00 0.00 337.71
May 1886.27 18-MAY-15:00 1465.40 1092.83 1538.38 0.00 0.00 0.00 0.00 0.00 2.61
June 5805.39 15-JUN-07:02 4396.19 3278.49 4615.15 0.00 0.00 0.00 0.00 0.00 13.45
July 5943.30 03-JUL-07:02 3663.49 2952.96 3845.95 0.00 0.00 0.00 0.00 0.00 9.46
August 5857.36 21-AUG-06:01 1077.07 1881.54 2692.17 0.00 0.00 0.00 0.00 0.00 16.25
September 5849.31 05-SEP-07:02 3663.49 3152.95 3845.95 0.00 0.00 0.00 0.00 0.00 26.95
October 1976.48 11-OCT-15:13 2930.79 2540.68 3076.76 0.00 0.00 0.00 0.00 5.01 0.00
November 1018.56 29-NOV-06:04 564.18 1286.00 2692.17 0.00 0.00 0.00 0.00 0.00 226.99
December 959.03 07-DEC-07:04 1077.07 2348.29 2692.17 0.00 0.00 0.00 0.00 0.00 70.83
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 830.29   564.18 1092.83 1538.38 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 5943.30   4396.19 3278.49 4615.15 0.00 0.00 0.00 0.00 5.01 337.71



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 896.85 20-JAN-16:22 2173.23 1981.33 2281.47 0.00 0.00 0.00 0.00 0.00 6.97
February 638.16 17-FEB-16:33 1738.59 1296.56 1825.18 0.00 0.00 0.00 0.00 0.00 14.48
March 1880.79 15-MAR-15:55 1738.59 1296.56 1825.18 0.00 0.00 0.00 0.00 0.00 8.55
April 1463.57 07-APR-15:53 1303.94 972.42 1368.88 0.00 0.00 0.00 0.00 0.00 14.49
May 2107.50 31-MAY-15:57 1303.94 972.42 1368.88 0.00 0.00 0.00 0.00 7.97 0.00
June 6187.67 26-JUN-06:01 638.93 1277.74 1597.03 0.00 0.00 0.00 0.00 0.00 10.06
July 6125.43 03-JUL-07:02 2173.23 1860.47 2281.47 0.00 0.00 0.00 0.00 0.00 6.14
August 6251.28 21-AUG-06:01 638.93 1303.98 1597.03 0.00 0.00 0.00 0.00 0.00 11.53
September 6123.92 11-SEP-06:01 638.93 1346.14 1597.03 0.00 0.00 0.00 0.00 0.00 10.26
October 3054.23 11-OCT-15:54 2173.23 1620.70 2281.47 0.00 0.00 0.00 0.00 0.24 0.00
November 1719.69 07-NOV-15:53 1738.59 1296.56 1825.18 0.00 0.00 0.00 0.00 0.00 2.61
December 569.26 04-DEC-15:33 1303.94 972.42 1368.88 0.00 0.00 0.00 0.00 0.00 17.84
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 569.26   638.93 972.42 1368.88 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 6251.28   2173.23 1981.33 2281.47 0.00 0.00 0.00 0.00 7.97 17.84



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: ATTIC

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY [] ZONE LIGHTS TOTAL HEATING ENERGY [] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 0.00 01-JAN-00:05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1055.15 0.00
February 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 496.12 0.00
March 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 392.47 0.00
April 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 569.94 0.00
May 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 377.43 0.00
June 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 628.04 0.00
July 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 786.76 0.00
August 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 409.26 0.00
September 0.00 01-SEP-00:05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 75.43 0.00
October 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 386.04 0.00
November 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 516.33 0.00
December 0.00 01-DEC-00:05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1364.62 0.00
                       
Annual Sum or Average     0.00 0.00 0.00 0.00 0.00 0.00 0.00    
Minimum of Months 0.00   0.00 0.00 0.00 0.00 0.00 0.00 0.00 75.43 0.00
Maximum of Months 0.00   0.00 0.00 0.00 0.00 0.00 0.00 0.00 1364.62 0.00



Table of Contents

Report: EnergyConsumptionElectricityNaturalGasMonthly

For: Meter

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum} [W] ELECTRICITY:FACILITY {TIMESTAMP} NATURALGAS:FACILITY [J] NATURALGAS:FACILITY {Maximum} [W] NATURALGAS:FACILITY {TIMESTAMP}
January 0.180366E+11 20285.65 03-JAN-08:20 0.184646E+10 33624.72 05-JAN-07:10
February 0.168593E+11 19894.67 06-FEB-08:39 0.151838E+10 26909.60 06-FEB-07:10
March 0.176510E+11 20717.85 20-MAR-07:00 0.501392E+09 14370.47 19-MAR-08:09
April 0.150664E+11 19730.04 03-APR-08:20 0.364332E+09 20681.92 03-APR-06:10
May 0.148522E+11 14556.19 02-MAY-07:10 11934368.71 5600.70 02-MAY-06:10
June 0.167336E+11 18494.20 26-JUN-15:20 0.00 0.00 01-JUN-00:10
July 0.161483E+11 17985.58 17-JUL-12:39 0.00 0.00 01-JUL-00:10
August 0.177197E+11 17935.03 16-AUG-15:30 0.00 0.00 01-AUG-00:10
September 0.158455E+11 16907.16 12-SEP-15:00 33233.82 55.39 22-SEP-07:10
October 0.162145E+11 19687.21 30-OCT-07:30 0.343243E+09 18025.36 30-OCT-06:10
November 0.165604E+11 19324.34 29-NOV-08:09 0.559558E+09 20457.02 29-NOV-17:00
December 0.166678E+11 18417.72 11-DEC-08:20 0.604654E+10 33968.21 22-DEC-07:10
             
Annual Sum or Average 0.198355E+12     0.111919E+11    
Minimum of Months 0.148522E+11 14556.19   0.00 0.00  
Maximum of Months 0.180366E+11 20717.85   0.604654E+10 33968.21  



Table of Contents

Report: EndUseEnergyConsumptionElectricityMonthly

For: Meter

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

INTERIORLIGHTS:ELECTRICITY [J] EXTERIORLIGHTS:ELECTRICITY [J] INTERIOREQUIPMENT:ELECTRICITY [J] EXTERIOREQUIPMENT:ELECTRICITY [] FANS:ELECTRICITY [J] PUMPS:ELECTRICITY [J] HEATING:ELECTRICITY [J] COOLING:ELECTRICITY [J] HEATREJECTION:ELECTRICITY [] HUMIDIFIER:ELECTRICITY [] HEATRECOVERY:ELECTRICITY [] WATERSYSTEMS:ELECTRICITY [J] COGENERATION:ELECTRICITY []
January 0.363895E+10 0.219261E+10 0.443459E+10 0.00 0.234534E+10 0.02 0.315147E+10 0.105413E+09 0.00 0.00 0.00 0.216825E+10 0.00
February 0.327048E+10 0.182477E+10 0.400939E+10 0.00 0.219838E+10 0.01 0.354716E+10 42417668.47 0.00 0.00 0.00 0.196668E+10 0.00
March 0.373769E+10 0.180058E+10 0.468012E+10 0.00 0.249569E+10 0.00 0.246441E+10 0.259483E+09 0.00 0.00 0.00 0.221307E+10 0.00
April 0.335441E+10 0.151990E+10 0.425568E+10 0.00 0.213254E+10 0.00 0.158483E+10 0.152353E+09 0.00 0.00 0.00 0.206664E+10 0.00
May 0.352978E+10 0.139171E+10 0.455735E+10 0.00 0.227674E+10 0.00 0.172753E+09 0.790731E+09 0.00 0.00 0.00 0.213312E+10 0.00
June 0.347427E+10 0.125887E+10 0.449372E+10 0.00 0.227900E+10 0.00 0.00 0.318402E+10 0.00 0.00 0.00 0.204367E+10 0.00
July 0.335125E+10 0.133313E+10 0.431556E+10 0.00 0.207487E+10 0.00 0.00 0.303783E+10 0.00 0.00 0.00 0.203562E+10 0.00
August 0.366338E+10 0.148507E+10 0.468012E+10 0.00 0.238245E+10 0.00 0.00 0.341980E+10 0.00 0.00 0.00 0.208893E+10 0.00
September 0.337125E+10 0.164554E+10 0.424819E+10 0.00 0.207566E+10 0.00 21298077.86 0.249840E+10 0.00 0.00 0.00 0.198520E+10 0.00
October 0.358688E+10 0.193000E+10 0.443833E+10 0.00 0.217671E+10 0.00 0.120891E+10 0.788683E+09 0.00 0.00 0.00 0.208502E+10 0.00
November 0.358463E+10 0.206401E+10 0.437470E+10 0.00 0.218512E+10 0.00 0.199701E+10 0.290551E+09 0.00 0.00 0.00 0.206432E+10 0.00
December 0.355468E+10 0.224740E+10 0.431182E+10 0.00 0.240716E+10 0.00 0.195084E+10 70839555.46 0.00 0.00 0.00 0.212507E+10 0.00
                           
Annual Sum or Average 0.421177E+11 0.206936E+11 0.527996E+11 0.00 0.270297E+11 0.03 0.160987E+11 0.146405E+11 0.00 0.00 0.00 0.249756E+11 0.00
Minimum of Months 0.327048E+10 0.125887E+10 0.400939E+10 0.00 0.207487E+10 0.00 0.00 42417668.47 0.00 0.00 0.00 0.196668E+10 0.00
Maximum of Months 0.373769E+10 0.224740E+10 0.468012E+10 0.00 0.249569E+10 0.02 0.354716E+10 0.341980E+10 0.00 0.00 0.00 0.221307E+10 0.00



Table of Contents

Report: EndUseEnergyConsumptionNaturalGasMonthly

For: Meter

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

INTERIOREQUIPMENT:NATURALGAS [] EXTERIOREQUIPMENT:NATURALGAS [] HEATING:NATURALGAS [J] COOLING:NATURALGAS [] WATERSYSTEMS:NATURALGAS [] COGENERATION:NATURALGAS [] HUMIDIFIER:NATURALGAS []
January 0.00 0.00 0.184646E+10 0.00 0.00 0.00 0.00
February 0.00 0.00 0.151838E+10 0.00 0.00 0.00 0.00
March 0.00 0.00 0.501392E+09 0.00 0.00 0.00 0.00
April 0.00 0.00 0.364332E+09 0.00 0.00 0.00 0.00
May 0.00 0.00 11934368.71 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 33233.82 0.00 0.00 0.00 0.00
October 0.00 0.00 0.343243E+09 0.00 0.00 0.00 0.00
November 0.00 0.00 0.559558E+09 0.00 0.00 0.00 0.00
December 0.00 0.00 0.604654E+10 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.111919E+11 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.604654E+10 0.00 0.00 0.00 0.00



Table of Contents

Report: PeakEnergyEndUseElectricityPart1Monthly

For: Meter

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

INTERIORLIGHTS:ELECTRICITY {Maximum} [W] INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} EXTERIOREQUIPMENT:ELECTRICITY [] FANS:ELECTRICITY {Maximum} [W] FANS:ELECTRICITY {TIMESTAMP} PUMPS:ELECTRICITY {Maximum} [W] PUMPS:ELECTRICITY {TIMESTAMP} HEATING:ELECTRICITY {Maximum} [W] HEATING:ELECTRICITY {TIMESTAMP}
January 3238.93 02-JAN-16:49 1574.40 01-JAN-06:10 3465.65 02-JAN-08:09 0.00 2211.29 02-JAN-06:10 0.00 05-JAN-08:09 9659.81 17-JAN-07:30
February 3220.59 06-FEB-16:00 1574.40 01-FEB-06:10 3465.65 01-FEB-08:09 0.00 2211.29 01-FEB-06:10 0.00 01-FEB-11:20 9005.52 06-FEB-18:10
March 3165.39 21-MAR-07:10 1574.40 01-MAR-06:10 3465.65 01-MAR-08:09 0.00 2211.29 01-MAR-06:10 0.00 01-MAR-00:10 10089.60 20-MAR-06:30
April 3137.99 03-APR-07:10 1574.40 01-APR-05:10 3465.65 03-APR-07:10 0.00 2211.29 03-APR-05:10 0.00 01-APR-00:10 9128.01 03-APR-06:30
May 2961.44 19-MAY-07:10 1574.40 01-MAY-18:49 3465.65 01-MAY-07:10 0.00 2211.29 01-MAY-05:10 0.00 01-MAY-00:10 6128.73 02-MAY-06:30
June 2999.02 16-JUN-07:10 1574.40 01-JUN-19:19 3465.65 01-JUN-07:10 0.00 2211.29 01-JUN-05:10 0.00 01-JUN-00:10 0.00 01-JUN-00:10
July 2972.55 28-JUL-07:10 1574.40 01-JUL-19:30 3465.65 03-JUL-07:10 0.00 2211.29 03-JUL-05:10 0.00 01-JUL-00:10 0.00 01-JUL-00:10
August 3054.50 28-AUG-15:00 1574.40 01-AUG-19:10 3465.65 01-AUG-07:10 0.00 2211.29 01-AUG-05:10 0.00 01-AUG-00:10 0.00 01-AUG-00:10
September 3057.75 21-SEP-15:00 1574.40 01-SEP-05:10 3465.65 01-SEP-07:10 0.00 2211.29 01-SEP-05:10 0.00 01-SEP-00:10 1440.17 22-SEP-06:19
October 3195.75 30-OCT-07:10 1574.40 01-OCT-05:10 3465.65 02-OCT-07:10 0.00 2211.29 02-OCT-05:10 0.00 01-OCT-00:10 8446.67 31-OCT-06:30
November 3238.93 06-NOV-16:49 1574.40 01-NOV-05:10 3465.65 01-NOV-07:10 0.00 2211.29 01-NOV-05:10 0.00 01-NOV-00:10 8962.97 01-NOV-06:30
December 3238.93 01-DEC-16:30 1574.40 01-DEC-06:10 3465.65 01-DEC-08:09 0.00 2211.29 01-DEC-06:10 0.00 01-DEC-00:10 7777.14 11-DEC-07:30
                           
Annual Sum or Average             0.00            
Minimum of Months 2961.44   1574.40   3465.65   0.00 2211.29   0.00   0.00  
Maximum of Months 3238.93   1574.40   3465.65   0.00 2211.29   0.00   10089.60  



Table of Contents

Report: PeakEnergyEndUseElectricityPart2Monthly

For: Meter

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

COOLING:ELECTRICITY {Maximum} [W] COOLING:ELECTRICITY {TIMESTAMP} HEATREJECTION:ELECTRICITY [] HUMIDIFIER:ELECTRICITY [] HEATRECOVERY:ELECTRICITY [] WATERSYSTEMS:ELECTRICITY {Maximum} [W] WATERSYSTEMS:ELECTRICITY {TIMESTAMP} COGENERATION:ELECTRICITY []
January 1306.40 20-JAN-15:30 0.00 0.00 0.00 2824.76 31-JAN-12:50 0.00
February 678.35 27-FEB-15:30 0.00 0.00 0.00 2825.56 14-FEB-12:20 0.00
March 2277.09 15-MAR-15:30 0.00 0.00 0.00 2824.36 06-MAR-12:20 0.00
April 1363.37 20-APR-12:00 0.00 0.00 0.00 2819.18 03-APR-11:00 0.00
May 3119.46 17-MAY-14:09 0.00 0.00 0.00 2810.66 01-MAY-11:50 0.00
June 7344.76 26-JUN-14:00 0.00 0.00 0.00 2800.49 01-JUN-11:20 0.00
July 6853.47 17-JUL-12:00 0.00 0.00 0.00 2791.93 03-JUL-11:09 0.00
August 6771.13 16-AUG-15:00 0.00 0.00 0.00 2787.87 31-AUG-11:00 0.00
September 5672.45 12-SEP-15:00 0.00 0.00 0.00 2792.18 29-SEP-11:50 0.00
October 4133.86 11-OCT-14:50 0.00 0.00 0.00 2802.00 31-OCT-11:00 0.00
November 2302.27 07-NOV-15:20 0.00 0.00 0.00 2811.55 30-NOV-12:09 0.00
December 1035.63 04-DEC-15:20 0.00 0.00 0.00 2819.49 28-DEC-12:30 0.00
                 
Annual Sum or Average     0.00 0.00 0.00     0.00
Minimum of Months 678.35   0.00 0.00 0.00 2787.87   0.00
Maximum of Months 7344.76   0.00 0.00 0.00 2825.56   0.00



Table of Contents

Report: ElectricComponentsOfPeakDemandMonthly

For: Meter

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ELECTRICITY:FACILITY {Maximum} [W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] EXTERIOREQUIPMENT:ELECTRICITY [] FANS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] HEATREJECTION:ELECTRICITY []
January 20285.65 03-JAN-08:20 2892.18 3465.65 0.00 0.00 2211.29 0.00 8971.72 0.00 0.00
February 19894.67 06-FEB-08:39 3132.82 3465.65 0.00 0.00 2211.29 0.00 8338.05 0.00 0.00
March 20717.85 20-MAR-07:00 3078.47 3465.65 0.00 0.00 2211.29 0.00 9217.07 0.00 0.00
April 19730.04 03-APR-08:20 3041.52 3465.65 0.00 0.00 2211.29 0.00 8253.06 0.00 0.00
May 14556.19 02-MAY-07:10 2772.97 3465.65 0.00 0.00 2211.29 0.00 5534.28 0.00 0.00
June 18494.20 26-JUN-15:20 2730.42 3465.65 0.00 0.00 2211.29 0.00 0.00 7331.78 0.00
July 17985.58 17-JUL-12:39 2689.41 3465.65 0.00 0.00 2211.29 0.00 0.00 6842.49 0.00
August 17935.03 16-AUG-15:30 2850.55 3465.65 0.00 0.00 2211.29 0.00 0.00 6657.00 0.00
September 16907.16 12-SEP-15:00 2805.58 3465.65 0.00 0.00 2211.29 0.00 0.00 5672.45 0.00
October 19687.21 30-OCT-07:30 3173.20 3465.65 0.00 0.00 2211.29 0.00 8102.22 0.00 0.00
November 19324.34 29-NOV-08:09 3164.68 3465.65 0.00 0.00 2211.29 0.00 7742.88 0.00 0.00
December 18417.72 11-DEC-08:20 2883.36 3465.65 0.00 0.00 2211.29 0.00 7116.04 0.00 0.00
                       
Annual Sum or Average           0.00         0.00
Minimum of Months 14556.19   2689.41 3465.65 0.00 0.00 2211.29 0.00 0.00 0.00 0.00
Maximum of Months 20717.85   3173.20 3465.65 0.00 0.00 2211.29 0.00 9217.07 7331.78 0.00



Table of Contents

Report: PeakEnergyEndUseNaturalGasMonthly

For: Meter

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

INTERIOREQUIPMENT:NATURALGAS [] EXTERIOREQUIPMENT:NATURALGAS [] HEATING:NATURALGAS {Maximum} [W] HEATING:NATURALGAS {TIMESTAMP} COOLING:NATURALGAS [] WATERSYSTEMS:NATURALGAS [] COGENERATION:NATURALGAS []
January 0.00 0.00 33624.72 05-JAN-07:10 0.00 0.00 0.00
February 0.00 0.00 26909.60 06-FEB-07:10 0.00 0.00 0.00
March 0.00 0.00 14370.47 19-MAR-08:09 0.00 0.00 0.00
April 0.00 0.00 20681.92 03-APR-06:10 0.00 0.00 0.00
May 0.00 0.00 5600.70 02-MAY-06:10 0.00 0.00 0.00
June 0.00 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00
July 0.00 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00
August 0.00 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00
September 0.00 0.00 55.39 22-SEP-07:10 0.00 0.00 0.00
October 0.00 0.00 18025.36 30-OCT-06:10 0.00 0.00 0.00
November 0.00 0.00 20457.02 29-NOV-17:00 0.00 0.00 0.00
December 0.00 0.00 33968.21 22-DEC-07:10 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00     0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00   0.00 0.00 0.00
Maximum of Months 0.00 0.00 33968.21   0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.17 19.25 0.17 19.25 0.00 19.25 0.00 19.25
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.33 24.69 0.33 24.69
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.17 24.47 0.17 24.47
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.33 19.11 0.33 19.11 0.00 19.11 0.00 19.11
                 
Annual Sum or Average 0.50 19.16 0.50 19.16 0.50 20.98 0.50 21.89
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.33 19.25 0.33 19.25 0.33 24.69 0.33 24.69



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 3.67 19.01 3.67 19.01 0.00 19.01 0.00 19.01
February 12.50 15.26 1.83 15.68 0.00 15.68 0.00 15.68
March 4.33 14.77 0.00 14.77 0.00 14.77 0.00 14.77
April 3.83 16.00 1.00 16.65 0.00 16.65 0.00 16.65
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.17 24.49 0.17 24.49
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 5.00 26.52 3.33 25.79
October 0.00 0.00 0.00 0.00 5.17 25.65 4.17 25.18
November 0.33 19.30 0.33 19.30 0.00 19.30 0.00 19.30
December 20.67 16.87 12.33 17.42 0.00 17.42 0.00 17.42
                 
Annual Sum or Average 45.33 16.34 19.17 17.00 10.33 18.25 7.67 18.84
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 20.67 19.30 12.33 19.30 5.17 26.52 4.17 25.79



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 13.33 14.89 0.17 14.94 0.00 14.94 0.00 14.94
February 18.67 14.48 0.33 14.49 0.00 14.49 0.00 14.49
March 11.00 14.70 0.00 14.70 0.00 14.70 0.00 14.70
April 5.83 14.84 0.00 14.84 0.00 14.84 0.00 14.84
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.17 30.01 0.00 30.01
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.33 14.94 0.00 14.94 0.00 14.94 0.00 14.94
December 24.33 14.82 2.17 15.03 0.00 15.03 0.00 15.03
                 
Annual Sum or Average 73.50 14.73 2.67 14.82 0.17 14.85 0.00 14.85
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 24.33 14.94 2.17 15.03 0.17 30.01 0.00 30.01



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 21.67 14.84 0.33 14.91 0.00 14.91 0.00 14.91
February 20.33 14.53 0.00 14.53 0.00 14.53 0.00 14.53
March 12.00 14.77 0.00 14.77 0.00 14.77 0.00 14.77
April 5.17 14.87 0.00 14.87 0.00 14.87 0.00 14.87
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.17 14.94 0.00 14.94 0.00 14.94 0.00 14.94
December 31.67 15.01 3.17 15.33 0.00 15.33 0.00 15.33
                 
Annual Sum or Average 91.00 14.82 3.50 14.96 0.00 14.96 0.00 14.96
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 31.67 15.01 3.17 15.33 0.00 15.33 0.00 15.33



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 11.83 14.89 0.17 14.95 0.00 14.95 0.00 14.95
February 17.67 14.50 0.17 14.51 0.00 14.51 0.00 14.51
March 11.00 14.70 0.00 14.70 0.00 14.70 0.00 14.70
April 6.17 14.83 0.00 14.83 0.00 14.83 0.00 14.83
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 1.67 30.21 0.33 30.19
July 0.00 0.00 0.00 0.00 2.33 30.27 0.00 30.27
August 0.00 0.00 0.00 0.00 1.00 30.26 0.00 30.26
September 0.00 0.00 0.00 0.00 1.33 30.26 0.00 30.26
October 0.17 14.99 0.00 14.99 0.00 14.99 0.00 14.99
November 0.17 14.93 0.00 14.93 0.00 14.93 0.00 14.93
December 26.00 14.84 2.00 15.06 0.00 15.06 0.00 15.06
                 
Annual Sum or Average 73.00 14.75 2.33 14.84 6.33 16.04 0.33 16.09
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 26.00 14.99 2.00 15.06 2.33 30.27 0.33 30.27



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: ATTIC

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: ComfortReportSimple55Monthly

For: CORE_ZN

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 357.00 21.53 115.67 21.23 115.67 21.06
February 323.00 21.30 140.17 21.03 140.17 20.89
March 369.50 22.07 69.67 21.79 69.67 21.58
April 340.00 22.53 44.50 22.27 44.50 22.07
May 167.33 23.31 53.17 23.58 6.67 23.50
June 11.17 26.75 357.00 24.99 11.17 25.04
July 31.50 26.50 339.67 25.08 31.50 25.19
August 8.33 26.42 378.00 24.98 8.33 25.01
September 15.33 24.34 246.00 25.00 2.00 25.02
October 196.50 22.74 55.50 22.89 21.33 22.69
November 346.17 22.27 54.50 22.01 54.50 21.81
December 340.00 21.43 144.83 21.14 144.83 20.99
             
Annual Sum or Average 2505.83 22.14 1998.67 22.79 650.33 22.55
Minimum of Months 8.33 21.30 44.50 21.03 2.00 20.89
Maximum of Months 369.50 26.75 378.00 25.08 144.83 25.19



Table of Contents

Report: ComfortReportSimple55Monthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 332.83 21.32 161.00 20.87 161.00 20.65
February 313.33 21.14 171.67 20.73 171.67 20.54
March 360.50 21.50 183.50 21.03 183.50 20.80
April 340.00 21.54 153.83 21.11 153.83 20.88
May 352.17 22.69 62.17 22.34 61.33 22.08
June 34.50 23.96 180.50 25.09 4.00 25.11
July 33.00 24.67 257.83 24.87 28.00 24.86
August 14.83 24.64 299.67 24.99 5.17 25.01
September 52.17 23.59 220.00 24.80 6.50 24.82
October 205.83 21.83 128.17 21.89 79.00 21.56
November 287.00 21.64 112.83 21.24 108.00 20.98
December 326.83 21.03 190.00 20.59 190.00 20.39
             
Annual Sum or Average 2653.00 21.71 2121.17 22.03 1152.00 21.68
Minimum of Months 14.83 21.03 62.17 20.59 4.00 20.39
Maximum of Months 360.50 24.67 299.67 25.09 190.00 25.11



Table of Contents

Report: ComfortReportSimple55Monthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 294.00 20.26 247.33 20.06 247.33 19.99
February 266.00 20.04 231.33 19.89 231.33 19.84
March 322.00 21.10 200.17 20.64 200.17 20.44
April 279.17 21.50 130.33 20.99 130.33 20.73
May 259.83 22.90 39.33 22.62 35.00 22.37
June 8.33 26.62 262.83 25.26 5.17 25.32
July 21.50 26.63 272.83 25.19 21.50 25.29
August 5.50 26.69 277.33 25.23 4.67 25.26
September 38.00 23.38 155.67 24.85 2.00 24.81
October 272.67 22.28 80.83 21.77 79.67 21.44
November 294.00 21.09 171.50 20.65 171.50 20.45
December 280.00 20.07 246.67 19.93 246.67 19.87
             
Annual Sum or Average 2341.00 21.25 2316.17 21.67 1375.33 21.29
Minimum of Months 5.50 20.04 39.33 19.89 2.00 19.84
Maximum of Months 322.00 26.69 277.33 25.26 247.33 25.32



Table of Contents

Report: ComfortReportSimple55Monthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 357.00 20.20 331.67 20.13 331.67 20.11
February 323.00 20.04 320.83 20.04 320.83 20.04
March 391.00 20.79 299.67 20.53 299.67 20.42
April 340.00 21.11 208.83 20.78 208.83 20.63
May 358.33 22.78 62.33 22.45 60.83 22.19
June 20.50 24.65 211.50 25.20 4.33 25.25
July 14.00 25.16 276.00 24.90 14.00 24.91
August 12.83 24.18 247.83 25.00 2.33 25.00
September 108.83 23.58 115.67 24.33 2.00 24.30
October 355.33 22.11 114.00 21.64 114.00 21.36
November 357.00 20.82 252.00 20.55 252.00 20.43
December 340.00 20.11 325.83 20.07 325.83 20.05
             
Annual Sum or Average 2977.83 21.16 2766.17 21.39 1936.33 21.09
Minimum of Months 12.83 20.04 62.33 20.04 2.00 20.04
Maximum of Months 391.00 25.16 331.67 25.20 331.67 25.25



Table of Contents

Report: ComfortReportSimple55Monthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 357.00 20.70 263.50 20.43 263.50 20.32
February 323.00 20.51 261.83 20.30 261.83 20.22
March 380.17 21.37 235.33 20.97 231.83 20.77
April 332.00 21.73 150.67 21.30 148.17 21.06
May 289.50 22.99 64.50 22.91 40.67 22.68
June 58.00 28.24 278.67 26.01 52.00 26.38
July 44.50 27.85 299.50 25.53 44.50 25.80
August 55.00 28.11 318.00 25.78 50.00 26.10
September 76.50 24.48 191.50 25.15 17.00 25.27
October 283.50 22.33 106.00 22.03 85.33 21.70
November 354.00 21.44 188.33 21.00 188.33 20.79
December 340.00 20.51 274.83 20.28 274.83 20.19
             
Annual Sum or Average 2893.17 21.84 2632.67 22.11 1658.00 21.84
Minimum of Months 44.50 20.51 64.50 20.28 17.00 20.19
Maximum of Months 380.17 28.24 318.00 26.01 274.83 26.38



Table of Contents

Report: ComfortReportSimple55Monthly

For: ATTIC

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00
             
Annual Sum or Average 0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 357.00000 0.00000 0.00000 0.00000 0.00000
February 323.00000 0.00000 0.00000 0.00000 0.00000
March 391.00000 0.00000 0.00000 0.00000 0.00000
April 340.00000 0.00000 0.00000 0.00000 0.00000
May 374.00000 0.00000 0.00000 0.00000 0.00000
June 374.00000 0.00000 0.00000 0.00000 0.00000
July 340.00000 0.00000 0.00000 0.00000 0.00000
August 391.00000 0.00000 0.00000 0.00000 0.00000
September 340.00000 0.00000 0.00000 0.00000 0.00000
October 357.00000 0.00000 0.00000 0.00000 0.00000
November 357.00000 0.00000 0.00000 0.00000 0.00000
December 340.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 4284.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 323.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 391.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 357.00000 0.00000 0.00000 0.00000 0.00000
February 323.00000 0.00000 0.00000 0.00000 0.00000
March 391.00000 0.00000 0.00000 0.00000 0.00000
April 340.00000 0.00000 0.00000 0.00000 0.00000
May 374.00000 0.00000 0.00000 0.00000 0.00000
June 374.00000 0.00000 0.00000 0.00000 0.00000
July 340.00000 0.00000 0.00000 0.00000 0.00000
August 391.00000 0.00000 0.00000 0.00000 0.00000
September 340.00000 0.00000 0.00000 0.00000 0.00000
October 357.00000 0.00000 0.00000 0.00000 0.00000
November 357.00000 0.00000 0.00000 0.00000 0.00000
December 340.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 4284.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 323.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 391.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 294.00000 0.00000 0.00000 0.00000 0.00000
February 266.00000 0.00000 0.00000 0.00000 0.00000
March 322.00000 0.00000 0.00000 0.00000 0.00000
April 280.00000 0.00000 0.00000 0.00000 0.00000
May 308.00000 0.00000 0.00000 0.00000 0.00000
June 308.00000 0.00000 0.00000 0.00000 0.00000
July 280.00000 0.00000 0.00000 0.00000 0.00000
August 322.00000 0.00000 0.00000 0.00000 0.00000
September 280.00000 0.00000 0.00000 0.00000 0.00000
October 294.00000 0.00000 0.00000 0.00000 0.00000
November 294.00000 0.00000 0.00000 0.00000 0.00000
December 280.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 3528.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 266.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 322.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 357.00000 0.00000 0.00000 0.00000 0.00000
February 323.00000 0.00000 0.00000 0.00000 0.00000
March 391.00000 0.00000 0.00000 0.00000 0.00000
April 340.00000 0.00000 0.00000 0.00000 0.00000
May 374.00000 0.00000 0.00000 0.00000 0.00000
June 374.00000 0.00000 0.00000 0.00000 0.00000
July 340.00000 0.00000 0.00000 0.00000 0.00000
August 391.00000 0.00000 0.00000 0.00000 0.00000
September 340.00000 0.00000 0.00000 0.00000 0.00000
October 357.00000 0.00000 0.00000 0.00000 0.00000
November 357.00000 0.00000 0.00000 0.00000 0.00000
December 340.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 4284.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 323.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 391.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 357.00000 0.00000 0.00000 0.00000 0.00000
February 323.00000 0.00000 0.00000 0.00000 0.00000
March 391.00000 0.00000 0.00000 0.00000 0.00000
April 340.00000 0.00000 0.00000 0.00000 0.00000
May 374.00000 0.00000 0.00000 0.00000 0.00000
June 374.00000 0.00000 0.00000 0.00000 0.00000
July 340.00000 0.00000 0.00000 0.00000 0.00000
August 391.00000 0.00000 0.00000 0.00000 0.00000
September 340.00000 0.00000 0.00000 0.00000 0.00000
October 357.00000 0.00000 0.00000 0.00000 0.00000
November 357.00000 0.00000 0.00000 0.00000 0.00000
December 340.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 4284.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 323.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 391.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: DXReportMonthly

For: PSZ-AC:1 HP COOLING COIL

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 53186946.73 11998903.66 27.33 52368052.84 818893.89 0.00 0.18 25-JAN-15:57 0.00 01-JAN-00:05 958.64 25-JAN-15:57 958.64 25-JAN-15:57 71.77 27-JAN-15:53 214.44 25-JAN-15:57 0.00
February 2557088.37 584021.14 4.04 2542428.26 14660.12 0.00 0.05 27-FEB-16:24 0.00 01-FEB-00:10 279.20 27-FEB-16:24 279.20 27-FEB-16:24 6.51 17-FEB-17:00 63.66 27-FEB-16:24 0.00
March 0.315510E+09 69941823.92 70.65 0.309236E+09 6273325.38 0.00 0.43 15-MAR-14:30 0.00 01-MAR-00:10 2400.41 15-MAR-14:30 2400.41 15-MAR-14:30 285.34 17-MAR-14:33 516.21 15-MAR-14:30 0.00
April 0.236118E+09 52695084.32 71.14 0.224026E+09 12092192.06 0.00 0.30 20-APR-13:33 0.00 01-APR-00:10 1681.68 20-APR-13:25 1648.98 20-APR-13:45 358.07 28-APR-14:00 373.55 20-APR-13:15 0.00
May 0.128153E+10 0.286650E+09 189.31 0.117245E+10 0.109086E+09 0.00 1.00 17-MAY-07:01 0.00 01-MAY-00:10 6329.10 18-MAY-07:02 6310.07 17-MAY-07:01 838.69 25-MAY-07:02 1241.85 18-MAY-07:02 0.00
June 0.356214E+10 0.827656E+09 237.94 0.332419E+10 0.237947E+09 0.00 1.00 01-JUN-07:03 0.00 01-JUN-00:10 6779.70 21-JUN-07:02 6466.81 30-JUN-06:03 1923.95 21-JUN-07:13 1618.88 26-JUN-14:55 0.00
July 0.357754E+10 0.809955E+09 221.70 0.325627E+10 0.321270E+09 0.00 1.00 03-JUL-06:02 0.00 01-JUL-00:10 6830.87 28-JUL-07:02 6497.14 18-JUL-06:01 2162.31 28-JUL-07:15 1550.52 17-JUL-13:00 0.00
August 0.384950E+10 0.874269E+09 252.28 0.355831E+10 0.291187E+09 0.00 1.00 01-AUG-07:02 0.00 01-AUG-00:10 6827.69 04-AUG-07:02 6474.46 21-AUG-06:01 2005.79 04-AUG-07:12 1463.42 16-AUG-14:00 0.00
September 0.281415E+10 0.622703E+09 213.17 0.269744E+10 0.116706E+09 0.00 1.00 01-SEP-07:02 0.00 01-SEP-00:05 6553.91 06-SEP-07:02 6381.10 11-SEP-06:01 1081.16 06-SEP-07:14 1317.13 11-SEP-12:20 0.00
October 0.100024E+10 0.218903E+09 146.76 0.965582E+09 34658594.32 0.00 1.00 02-OCT-07:03 0.00 01-OCT-00:10 6185.38 10-OCT-07:03 6185.38 10-OCT-07:03 364.55 03-OCT-13:20 1209.16 10-OCT-07:03 0.00
November 0.256523E+09 56922133.14 69.26 0.247567E+09 8955515.97 0.00 0.39 09-NOV-13:57 0.00 01-NOV-00:10 2198.92 09-NOV-13:57 2108.63 09-NOV-13:57 143.32 09-NOV-17:00 477.86 09-NOV-14:00 0.00
December 10992593.19 2486640.31 8.66 10992072.13 521.06 0.00 0.14 04-DEC-15:37 0.00 01-DEC-00:05 777.00 04-DEC-15:37 777.00 04-DEC-15:37 0.32 15-DEC-15:30 174.69 04-DEC-15:37 0.00
                                       
Annual Sum or Average 0.169600E+11 0.383476E+10 1512.25 0.158210E+11 0.113901E+10 0.00                         0.00
Minimum of Months 2557088.37 584021.14 4.04 2542428.26 521.06 0.00 0.05   0.00   279.20   279.20   0.32   63.66   0.00
Maximum of Months 0.384950E+10 0.874269E+09 252.28 0.355831E+10 0.321270E+09 0.00 1.00   0.00   6830.87   6497.14   2162.31   1618.88   0.00



Table of Contents

Report: DXReportMonthly

For: PSZ-AC:2 HP COOLING COIL

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.397581E+09 85730881.96 62.35 0.397397E+09 184407.83 0.00 0.65 20-JAN-14:15 0.00 01-JAN-00:05 4079.31 20-JAN-14:15 4079.31 20-JAN-14:15 28.86 10-JAN-15:40 846.44 20-JAN-14:15 0.00
February 0.182376E+09 40216714.72 44.96 0.182376E+09 0.00 0.00 0.46 27-FEB-14:15 0.00 01-FEB-00:10 2838.88 27-FEB-14:15 2838.88 27-FEB-14:15 0.00 22-FEB-11:50 606.99 27-FEB-14:15 0.00
March 0.525090E+09 0.113500E+09 74.80 0.525090E+09 -0.0 0.00 0.72 14-MAR-13:30 0.00 01-MAR-00:10 4550.19 14-MAR-13:30 4550.19 14-MAR-13:30 0.00 31-MAR-16:15 974.57 14-MAR-13:30 0.00
April 0.171631E+09 38196273.41 48.90 0.170787E+09 844742.28 0.00 0.33 20-APR-13:00 0.00 01-APR-00:10 1983.15 20-APR-13:00 1983.15 20-APR-13:00 97.77 28-APR-14:30 439.95 20-APR-13:00 0.00
May 0.547758E+09 0.127030E+09 117.80 0.540330E+09 7427886.53 0.00 0.50 17-MAY-13:50 0.00 01-MAY-00:10 2937.95 17-MAY-13:50 2937.95 17-MAY-13:50 149.91 30-MAY-16:00 732.73 17-MAY-13:50 0.00
June 0.270221E+10 0.660016E+09 222.99 0.260392E+10 98288395.30 0.00 1.00 06-JUN-07:02 0.00 01-JUN-00:10 6994.16 19-JUN-07:02 6883.56 26-JUN-07:01 1259.00 22-JUN-07:02 1695.18 26-JUN-16:10 0.00
July 0.274577E+10 0.650886E+09 204.36 0.259476E+10 0.151015E+09 0.00 1.00 07-JUL-07:02 0.00 01-JUL-00:10 7310.99 24-JUL-06:01 6887.13 18-JUL-06:01 1417.97 26-JUL-07:02 1638.51 17-JUL-11:55 0.00
August 0.346254E+10 0.810594E+09 231.07 0.332994E+10 0.132603E+09 0.00 1.00 03-AUG-07:02 0.00 01-AUG-00:10 7459.78 04-AUG-07:02 7011.87 21-AUG-06:01 2398.26 04-AUG-07:02 1666.83 16-AUG-16:10 0.00
September 0.310083E+10 0.688554E+09 207.60 0.307016E+10 30670511.73 0.00 1.00 05-SEP-06:02 0.00 01-SEP-00:05 7040.43 06-SEP-07:02 6906.41 13-SEP-07:02 813.74 06-SEP-07:02 1536.79 12-SEP-15:43 0.00
October 0.144551E+10 0.304464E+09 137.08 0.144349E+10 2014518.68 0.00 1.00 10-OCT-11:45 0.00 01-OCT-00:10 6631.59 10-OCT-11:45 6631.59 10-OCT-11:45 162.82 03-OCT-11:00 1418.52 11-OCT-14:00 0.00
November 0.797773E+09 0.168983E+09 91.32 0.797750E+09 22892.25 0.00 0.88 07-NOV-13:55 0.00 01-NOV-00:10 5746.67 07-NOV-13:55 5746.67 07-NOV-13:55 10.96 14-NOV-17:00 1164.60 07-NOV-13:55 0.00
December 0.295421E+09 64241713.86 50.68 0.295421E+09 -0.0 0.00 0.54 04-DEC-14:25 0.00 01-DEC-00:05 3336.45 04-DEC-14:25 3336.45 04-DEC-14:25 0.00 01-DEC-16:37 704.77 04-DEC-14:25 0.00
                                       
Annual Sum or Average 0.163745E+11 0.375241E+10 1493.91 0.159514E+11 0.423071E+09 0.00                         0.00
Minimum of Months 0.171631E+09 38196273.41 44.96 0.170787E+09 -0.0 0.00 0.33   0.00   1983.15   1983.15   0.00   439.95   0.00
Maximum of Months 0.346254E+10 0.810594E+09 231.07 0.332994E+10 0.151015E+09 0.00 1.00   0.00   7459.78   7011.87   2398.26   1695.18   0.00



Table of Contents

Report: DXReportMonthly

For: PSZ-AC:3 HP COOLING COIL

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 2506074.25 571310.75 3.69 2506074.25 0.00 0.00 0.13 20-JAN-14:00 0.00 01-JAN-00:05 571.33 20-JAN-14:00 571.33 20-JAN-14:00 0.00 20-JAN-13:50 128.81 20-JAN-14:00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 0.00 01-FEB-00:10 0.00 01-FEB-00:10 0.00 01-FEB-00:10 0.00 01-FEB-00:10 0.00 01-FEB-00:10 0.00
March 0.144391E+09 32432827.81 58.56 0.144391E+09 -0.0 0.00 0.32 14-MAR-10:12 0.00 01-MAR-00:10 1472.19 14-MAR-10:12 1472.19 14-MAR-10:12 0.00 16-MAR-15:36 322.28 14-MAR-10:12 0.00
April 0.148209E+09 33212027.97 64.68 0.147908E+09 300888.35 0.00 0.28 21-APR-10:05 0.00 01-APR-00:10 1301.27 21-APR-10:05 1301.27 21-APR-10:05 41.51 28-APR-15:20 286.44 21-APR-10:05 0.00
May 0.606990E+09 0.139119E+09 173.28 0.596680E+09 10309439.08 0.00 1.00 11-MAY-07:02 0.00 01-MAY-00:10 5293.33 17-MAY-07:01 5293.33 17-MAY-07:01 158.78 31-MAY-08:31 1037.15 17-MAY-07:01 0.00
June 0.230159E+10 0.551474E+09 237.57 0.223961E+10 61985439.71 0.00 1.00 02-JUN-07:02 0.00 01-JUN-00:10 5699.32 21-JUN-07:02 5459.82 26-JUN-06:01 1226.92 21-JUN-07:02 1151.75 26-JUN-15:00 0.00
July 0.213820E+10 0.506272E+09 229.37 0.205358E+10 84625118.76 0.00 1.00 03-JUL-07:02 0.00 01-JUL-00:10 5771.33 28-JUL-07:02 5413.89 18-JUL-06:01 1629.67 28-JUL-07:02 1251.91 17-JUL-10:23 0.00
August 0.243791E+10 0.571877E+09 252.49 0.235773E+10 80176071.45 0.00 1.00 01-AUG-07:02 0.00 01-AUG-00:10 5740.81 04-AUG-07:02 5497.96 21-AUG-06:01 1393.94 04-AUG-07:03 1121.98 04-AUG-07:02 0.00
September 0.171263E+10 0.390648E+09 205.25 0.169729E+10 15334296.59 0.00 1.00 01-SEP-07:02 0.00 01-SEP-00:05 5479.17 06-SEP-07:02 5393.50 14-SEP-07:02 434.99 06-SEP-07:12 1076.62 06-SEP-07:02 0.00
October 0.424940E+09 95128323.93 121.10 0.424224E+09 715483.71 0.00 0.54 11-OCT-07:02 0.00 01-OCT-00:10 2622.83 11-OCT-07:02 2622.83 11-OCT-07:02 56.10 03-OCT-11:00 553.63 11-OCT-07:02 0.00
November 0.107362E+09 24112344.71 50.66 0.107362E+09 0.00 0.00 0.24 09-NOV-13:13 0.00 01-NOV-00:10 1114.02 09-NOV-13:13 1114.02 09-NOV-13:13 0.00 09-NOV-13:20 246.72 09-NOV-13:13 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-DEC-00:05 0.00 01-DEC-00:05 0.00 01-DEC-00:05 0.00 01-DEC-00:05 0.00 01-DEC-00:05 0.00 01-DEC-00:05 0.00
                                       
Annual Sum or Average 0.100247E+11 0.234485E+10 1396.64 0.977128E+10 0.253447E+09 0.00                         0.00
Minimum of Months 0.00 0.00 0.00 0.00 -0.0 0.00 0.00   0.00   0.00   0.00   0.00   0.00   0.00
Maximum of Months 0.243791E+10 0.571877E+09 252.49 0.235773E+10 84625118.76 0.00 1.00   0.00   5771.33   5497.96   1629.67   1251.91   0.00



Table of Contents

Report: DXReportMonthly

For: PSZ-AC:4 HP COOLING COIL

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 0.00 01-JAN-00:05 0.00 01-JAN-00:05 0.00 01-JAN-00:05 0.00 01-JAN-00:05 0.00 01-JAN-00:05 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 0.00 01-FEB-00:10 0.00 01-FEB-00:10 0.00 01-FEB-00:10 0.00 01-FEB-00:10 0.00 01-FEB-00:10 0.00
March 31825065.13 7261965.61 15.94 31825065.13 0.00 0.00 0.18 15-MAR-15:27 0.00 01-MAR-00:10 921.25 15-MAR-15:27 921.25 15-MAR-15:27 0.00 14-MAR-12:30 206.11 15-MAR-15:27 0.00
April 14774713.13 3353378.03 12.60 14774713.13 -0.0 0.00 0.13 20-APR-14:00 0.00 01-APR-00:10 661.01 20-APR-14:00 661.01 20-APR-14:00 0.00 20-APR-14:55 149.01 20-APR-13:50 0.00
May 0.462804E+09 0.107506E+09 127.65 0.449746E+09 13058129.63 0.00 0.47 17-MAY-14:00 0.00 01-MAY-00:10 2478.87 17-MAY-14:00 2478.87 17-MAY-14:00 157.20 30-MAY-15:57 620.06 17-MAY-14:00 0.00
June 0.255850E+10 0.618829E+09 229.74 0.245861E+10 99892751.56 0.00 1.00 05-JUN-07:02 0.00 01-JUN-00:10 6564.06 21-JUN-07:02 6179.62 26-JUN-06:01 1715.85 21-JUN-07:02 1526.05 26-JUN-15:00 0.00
July 0.252095E+10 0.594521E+09 210.29 0.237764E+10 0.143308E+09 0.00 1.00 03-JUL-07:02 0.00 01-JUL-00:10 6597.84 28-JUL-07:02 6170.82 06-JUL-07:02 2003.77 31-JUL-07:02 1464.91 17-JUL-13:00 0.00
August 0.264204E+10 0.626447E+09 236.24 0.251817E+10 0.123878E+09 0.00 1.00 02-AUG-07:02 0.00 01-AUG-00:10 6641.35 04-AUG-07:02 6229.25 21-AUG-06:01 2011.23 04-AUG-07:12 1328.09 16-AUG-15:53 0.00
September 0.179740E+10 0.413450E+09 196.03 0.176875E+10 28651905.69 0.00 1.00 01-SEP-07:02 0.00 01-SEP-00:05 6271.11 06-SEP-07:02 6166.77 13-SEP-07:02 568.62 06-SEP-07:02 1232.22 06-SEP-07:02 0.00
October 0.256834E+09 58335597.66 75.54 0.256206E+09 627639.42 0.00 0.47 11-OCT-14:25 0.00 01-OCT-00:10 2505.84 11-OCT-14:47 2505.84 11-OCT-14:47 55.84 03-OCT-14:00 595.61 11-OCT-14:00 0.00
November 33728597.98 7599586.85 15.03 33728597.98 0.00 0.00 0.21 09-NOV-14:00 0.00 01-NOV-00:10 1079.77 09-NOV-13:57 1079.77 09-NOV-13:57 0.00 07-NOV-16:37 240.62 09-NOV-13:57 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-DEC-00:05 0.00 01-DEC-00:05 0.00 01-DEC-00:05 0.00 01-DEC-00:05 0.00 01-DEC-00:05 0.00 01-DEC-00:05 0.00
                                       
Annual Sum or Average 0.103189E+11 0.243730E+10 1119.04 0.990944E+10 0.409416E+09 0.00                         0.00
Minimum of Months 0.00 0.00 0.00 0.00 -0.0 0.00 0.00   0.00   0.00   0.00   0.00   0.00   0.00
Maximum of Months 0.264204E+10 0.626447E+09 236.24 0.251817E+10 0.143308E+09 0.00 1.00   0.00   6641.35   6229.25   2011.23   1526.05   0.00



Table of Contents

Report: DXReportMonthly

For: PSZ-AC:5 HP COOLING COIL

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 31536351.69 7111934.99 16.64 31536351.69 0.00 0.00 0.20 20-JAN-15:58 0.00 01-JAN-00:05 1166.27 20-JAN-15:58 1166.27 20-JAN-15:58 0.00 19-JAN-16:55 260.06 20-JAN-15:58 0.00
February 7122130.29 1616932.61 6.53 7122130.29 0.00 0.00 0.14 17-FEB-16:38 0.00 01-FEB-00:10 816.67 17-FEB-16:38 816.67 17-FEB-16:38 0.00 27-FEB-16:18 183.74 17-FEB-16:38 0.00
March 0.161701E+09 36346136.53 50.65 0.161701E+09 0.00 0.00 0.37 15-MAR-15:55 0.00 01-MAR-00:10 2222.83 15-MAR-15:55 2222.83 15-MAR-15:55 0.00 09-MAR-16:33 482.64 15-MAR-15:55 0.00
April 0.110449E+09 24896285.94 52.68 0.109650E+09 798993.72 0.00 0.31 07-APR-16:00 0.00 01-APR-00:10 1862.76 07-APR-16:00 1862.76 07-APR-16:00 95.69 28-APR-14:50 408.11 07-APR-16:00 0.00
May 0.563312E+09 0.130427E+09 157.43 0.547104E+09 16208423.31 0.00 0.46 31-MAY-15:53 0.00 01-MAY-00:10 2816.72 31-MAY-15:53 2708.16 31-MAY-15:57 186.49 22-MAY-15:53 686.38 31-MAY-15:53 0.00
June 0.211329E+10 0.526049E+09 248.18 0.204404E+10 69244893.19 0.00 1.00 05-JUN-07:02 0.00 01-JUN-00:10 7394.07 21-JUN-07:02 7022.78 26-JUN-06:01 1767.42 21-JUN-07:02 1509.67 25-JUN-17:42 0.00
July 0.195345E+10 0.476196E+09 228.59 0.185727E+10 96186257.46 0.00 1.00 03-JUL-07:02 0.00 01-JUL-00:10 7453.96 31-JUL-07:02 6974.30 18-JUL-06:01 2117.98 31-JUL-07:02 1478.03 24-JUL-07:02 0.00
August 0.220129E+10 0.536615E+09 259.93 0.211575E+10 85541595.61 0.00 1.00 03-AUG-07:02 0.00 01-AUG-00:10 7433.42 04-AUG-07:02 7085.68 21-AUG-06:01 1886.52 04-AUG-07:02 1544.69 26-AUG-17:22 0.00
September 0.163688E+10 0.383044E+09 212.68 0.161647E+10 20414616.97 0.00 1.00 05-SEP-07:02 0.00 01-SEP-00:05 7061.38 06-SEP-07:02 6950.00 13-SEP-07:02 417.35 06-SEP-07:02 1451.14 10-SEP-17:52 0.00
October 0.500328E+09 0.111852E+09 115.46 0.498922E+09 1405640.77 0.00 0.58 11-OCT-15:54 0.00 01-OCT-00:10 3539.03 11-OCT-15:54 3539.03 11-OCT-15:54 77.87 03-OCT-15:23 785.09 11-OCT-15:48 0.00
November 0.147120E+09 32934312.22 51.92 0.147114E+09 6488.20 0.00 0.35 07-NOV-15:58 0.00 01-NOV-00:10 2118.92 07-NOV-15:58 2118.92 07-NOV-15:58 3.38 14-NOV-16:40 461.27 07-NOV-15:58 0.00
December 18148145.72 4111201.29 12.40 18148145.72 0.00 0.00 0.15 04-DEC-15:40 0.00 01-DEC-00:05 873.29 04-DEC-15:40 873.29 04-DEC-15:40 0.00 13-DEC-16:02 196.20 04-DEC-15:40 0.00
                                       
Annual Sum or Average 0.944463E+10 0.227120E+10 1413.09 0.915482E+10 0.289807E+09 0.00                         0.00
Minimum of Months 7122130.29 1616932.61 6.53 7122130.29 0.00 0.00 0.14   0.00   816.67   816.67   0.00   183.74   0.00
Maximum of Months 0.220129E+10 0.536615E+09 259.93 0.211575E+10 96186257.46 0.00 1.00   0.00   7453.96   7085.68   2117.98   1544.69   0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 168.91 139.52 29.39 196.36 69.24 0.00 0.00 0.00
February 161.88 129.71 32.18 187.06 70.96 0.00 0.00 0.00
March 116.24 76.82 39.41 136.47 54.96 0.00 0.00 0.00
April 63.09 21.64 41.45 64.15 47.62 0.00 0.00 0.00
May 52.19 3.71 48.48 55.39 30.03 0.00 0.00 0.00
June 46.21 0.54 45.67 60.41 19.46 0.00 0.00 0.00
July 49.10 2.22 46.88 65.18 18.90 0.00 0.00 0.00
August 65.04 20.72 44.33 88.78 22.55 0.00 0.00 0.00
September 99.67 53.78 45.89 131.86 34.47 0.00 0.00 0.00
October 132.78 94.95 37.82 160.04 63.54 0.00 0.00 0.00
November 162.31 129.97 32.33 190.98 69.43 0.00 0.00 0.00
December 155.21 126.20 29.02 176.53 78.86 0.00 0.00 0.00
                 
Annual Sum or Average 105.74 66.30 39.44 125.76 48.21 0.00 0.00 0.00
Minimum of Months 46.21 0.54 29.02 55.39 18.90 0.00 0.00 0.00
Maximum of Months 168.91 139.52 48.48 196.36 78.86 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 168.91 139.52 29.39 196.36 69.24 0.00 0.00 0.00
February 161.88 129.71 32.18 187.06 70.96 0.00 0.00 0.00
March 116.23 76.82 39.41 136.47 54.96 0.00 0.00 0.00
April 62.94 21.58 41.37 63.90 47.64 0.00 0.00 0.00
May 52.16 3.70 48.45 55.33 30.03 0.00 0.00 0.00
June 46.20 0.54 45.66 60.41 19.46 0.00 0.00 0.00
July 49.09 2.22 46.87 65.16 18.90 0.00 0.00 0.00
August 64.93 20.66 44.27 88.58 22.55 0.00 0.00 0.00
September 99.56 53.73 45.83 131.68 34.49 0.00 0.00 0.00
October 132.78 94.95 37.82 160.04 63.54 0.00 0.00 0.00
November 162.31 129.97 32.33 190.98 69.43 0.00 0.00 0.00
December 155.21 126.20 29.01 176.53 78.86 0.00 0.00 0.00
                 
Annual Sum or Average 105.70 66.28 39.42 125.70 48.21 0.00 0.00 0.00
Minimum of Months 46.20 0.54 29.01 55.33 18.90 0.00 0.00 0.00
Maximum of Months 168.91 139.52 48.45 196.36 78.86 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 168.91 139.52 29.39 196.36 69.24 0.00 0.00 0.00
February 161.88 129.71 32.18 187.06 70.96 0.00 0.00 0.00
March 116.23 76.82 39.41 136.47 54.96 0.00 0.00 0.00
April 62.94 21.58 41.37 63.90 47.64 0.00 0.00 0.00
May 52.16 3.70 48.45 55.33 30.03 0.00 0.00 0.00
June 46.20 0.54 45.66 60.41 19.46 0.00 0.00 0.00
July 49.09 2.22 46.87 65.16 18.90 0.00 0.00 0.00
August 64.93 20.66 44.27 88.58 22.55 0.00 0.00 0.00
September 99.55 53.73 45.82 131.67 34.50 0.00 0.00 0.00
October 132.78 94.95 37.82 160.04 63.54 0.00 0.00 0.00
November 162.31 129.97 32.33 190.98 69.43 0.00 0.00 0.00
December 155.21 126.20 29.01 176.53 78.86 0.00 0.00 0.00
                 
Annual Sum or Average 105.70 66.28 39.42 125.70 48.22 0.00 0.00 0.00
Minimum of Months 46.20 0.54 29.01 55.33 18.90 0.00 0.00 0.00
Maximum of Months 168.91 139.52 48.45 196.36 78.86 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 168.91 139.52 29.39 196.36 69.24 0.00 0.00 0.00
February 161.88 129.71 32.18 187.06 70.96 0.00 0.00 0.00
March 116.23 76.82 39.41 136.47 54.96 0.00 0.00 0.00
April 62.94 21.58 41.37 63.90 47.64 0.00 0.00 0.00
May 52.16 3.70 48.45 55.33 30.03 0.00 0.00 0.00
June 46.20 0.54 45.66 60.41 19.46 0.00 0.00 0.00
July 49.09 2.22 46.87 65.16 18.90 0.00 0.00 0.00
August 64.93 20.66 44.27 88.58 22.55 0.00 0.00 0.00
September 99.55 53.73 45.82 131.66 34.50 0.00 0.00 0.00
October 132.78 94.95 37.82 160.04 63.54 0.00 0.00 0.00
November 162.31 129.97 32.33 190.98 69.43 0.00 0.00 0.00
December 155.21 126.20 29.01 176.53 78.86 0.00 0.00 0.00
                 
Annual Sum or Average 105.70 66.28 39.42 125.70 48.21 0.00 0.00 0.00
Minimum of Months 46.20 0.54 29.01 55.33 18.90 0.00 0.00 0.00
Maximum of Months 168.91 139.52 48.45 196.36 78.86 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 168.91 139.52 29.39 196.36 69.24 0.00 0.00 0.00
February 161.88 129.71 32.18 187.06 70.96 0.00 0.00 0.00
March 116.23 76.82 39.41 136.47 54.96 0.00 0.00 0.00
April 62.94 21.58 41.37 63.90 47.64 0.00 0.00 0.00
May 52.16 3.70 48.45 55.33 30.03 0.00 0.00 0.00
June 46.20 0.54 45.66 60.41 19.46 0.00 0.00 0.00
July 49.09 2.22 46.87 65.16 18.90 0.00 0.00 0.00
August 64.93 20.66 44.27 88.58 22.55 0.00 0.00 0.00
September 99.57 53.73 45.83 131.67 34.47 0.00 0.00 0.00
October 132.78 94.95 37.82 160.04 63.54 0.00 0.00 0.00
November 162.31 129.97 32.33 190.98 69.43 0.00 0.00 0.00
December 155.21 126.20 29.01 176.53 78.86 0.00 0.00 0.00
                 
Annual Sum or Average 105.70 66.28 39.42 125.70 48.21 0.00 0.00 0.00
Minimum of Months 46.20 0.54 29.01 55.33 18.90 0.00 0.00 0.00
Maximum of Months 168.91 139.52 48.45 196.36 78.86 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 168.91 139.52 29.39 196.36 69.24 0.00 0.00 0.00
February 161.88 129.71 32.18 187.06 70.96 0.00 0.00 0.00
March 116.24 76.82 39.41 136.47 54.96 0.00 0.00 0.00
April 63.15 21.67 41.48 64.21 47.57 0.00 0.00 0.00
May 52.19 3.71 48.48 55.39 30.03 0.00 0.00 0.00
June 46.21 0.54 45.67 60.41 19.46 0.00 0.00 0.00
July 49.10 2.22 46.88 65.19 18.90 0.00 0.00 0.00
August 65.08 20.74 44.35 88.87 22.55 0.00 0.00 0.00
September 99.69 53.79 45.90 131.81 34.38 0.00 0.00 0.00
October 132.78 94.95 37.82 160.04 63.54 0.00 0.00 0.00
November 162.31 129.97 32.33 190.98 69.43 0.00 0.00 0.00
December 155.21 126.20 29.02 176.53 78.86 0.00 0.00 0.00
                 
Annual Sum or Average 105.75 66.30 39.45 125.77 48.20 0.00 0.00 0.00
Minimum of Months 46.21 0.54 29.02 55.39 18.90 0.00 0.00 0.00
Maximum of Months 168.91 139.52 48.48 196.36 78.86 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_DOOR

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 237.13 195.47 41.66 275.51 96.61 0.00 0.00 0.00
February 227.36 181.72 45.64 262.58 98.79 0.00 0.00 0.00
March 167.08 110.56 56.51 196.60 76.38 0.00 0.00 0.00
April 102.26 40.03 62.23 110.30 65.94 0.00 0.00 0.00
May 84.96 11.11 73.85 96.12 41.91 0.00 0.00 0.00
June 74.44 6.51 67.93 100.73 27.39 0.00 0.00 0.00
July 79.76 8.90 70.86 108.91 26.55 0.00 0.00 0.00
August 108.44 41.77 66.66 151.59 31.68 0.00 0.00 0.00
September 155.30 87.28 68.02 207.40 48.28 0.00 0.00 0.00
October 186.75 133.03 53.72 224.61 88.46 0.00 0.00 0.00
November 227.91 182.10 45.81 267.95 96.77 0.00 0.00 0.00
December 217.94 176.81 41.14 247.76 109.83 0.00 0.00 0.00
                 
Annual Sum or Average 155.36 97.46 57.90 187.06 67.21 0.00 0.00 0.00
Minimum of Months 74.44 6.51 41.14 96.12 26.55 0.00 0.00 0.00
Maximum of Months 237.13 195.47 73.85 275.51 109.83 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_2_WALL_EAST_WINDOW_4

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 53.70 33.19 20.52 50.77 66.29 0.00 0.00 0.00
February 71.04 44.98 26.07 69.86 68.25 0.00 0.00 0.00
March 84.80 49.63 35.18 89.05 51.61 0.00 0.00 0.00
April 85.72 41.92 43.80 87.98 44.53 0.00 0.00 0.00
May 99.32 41.61 57.71 114.41 28.45 0.00 0.00 0.00
June 121.46 63.29 58.17 159.43 18.70 0.00 0.00 0.00
July 109.95 52.19 57.76 144.46 18.43 0.00 0.00 0.00
August 111.56 61.00 50.56 145.36 21.69 0.00 0.00 0.00
September 93.80 50.95 42.85 116.14 31.28 0.00 0.00 0.00
October 68.63 37.71 30.92 71.73 59.47 0.00 0.00 0.00
November 53.72 30.43 23.29 51.88 65.46 0.00 0.00 0.00
December 46.83 27.26 19.57 42.16 78.43 0.00 0.00 0.00
                 
Annual Sum or Average 83.42 44.49 38.94 95.38 45.93 0.00 0.00 0.00
Minimum of Months 46.83 27.26 19.57 42.16 18.43 0.00 0.00 0.00
Maximum of Months 121.46 63.29 58.17 159.43 78.43 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_2_WALL_EAST_WINDOW_3

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 53.70 33.19 20.52 50.77 66.29 0.00 0.00 0.00
February 71.04 44.98 26.06 69.86 68.25 0.00 0.00 0.00
March 84.80 49.63 35.18 89.05 51.60 0.00 0.00 0.00
April 85.72 41.92 43.80 87.98 44.53 0.00 0.00 0.00
May 99.31 41.61 57.70 114.41 28.45 0.00 0.00 0.00
June 121.46 63.29 58.16 159.43 18.70 0.00 0.00 0.00
July 109.95 52.19 57.76 144.46 18.43 0.00 0.00 0.00
August 111.56 61.00 50.56 145.36 21.69 0.00 0.00 0.00
September 93.80 50.95 42.85 116.14 31.28 0.00 0.00 0.00
October 68.63 37.71 30.92 71.73 59.47 0.00 0.00 0.00
November 53.72 30.43 23.29 51.88 65.46 0.00 0.00 0.00
December 46.83 27.26 19.57 42.16 78.43 0.00 0.00 0.00
                 
Annual Sum or Average 83.42 44.49 38.93 95.38 45.93 0.00 0.00 0.00
Minimum of Months 46.83 27.26 19.57 42.16 18.43 0.00 0.00 0.00
Maximum of Months 121.46 63.29 58.16 159.43 78.43 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_2_WALL_EAST_WINDOW_2

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 53.70 33.19 20.52 50.77 66.29 0.00 0.00 0.00
February 71.04 44.98 26.06 69.86 68.25 0.00 0.00 0.00
March 84.80 49.63 35.18 89.05 51.60 0.00 0.00 0.00
April 85.72 41.92 43.80 87.98 44.53 0.00 0.00 0.00
May 99.31 41.61 57.70 114.41 28.45 0.00 0.00 0.00
June 121.46 63.29 58.16 159.43 18.70 0.00 0.00 0.00
July 109.95 52.19 57.76 144.46 18.43 0.00 0.00 0.00
August 111.56 61.00 50.56 145.36 21.69 0.00 0.00 0.00
September 93.80 50.95 42.85 116.14 31.28 0.00 0.00 0.00
October 68.63 37.71 30.92 71.73 59.47 0.00 0.00 0.00
November 53.72 30.43 23.29 51.88 65.46 0.00 0.00 0.00
December 46.83 27.26 19.57 42.16 78.43 0.00 0.00 0.00
                 
Annual Sum or Average 83.42 44.49 38.93 95.38 45.93 0.00 0.00 0.00
Minimum of Months 46.83 27.26 19.57 42.16 18.43 0.00 0.00 0.00
Maximum of Months 121.46 63.29 58.16 159.43 78.43 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_2_WALL_EAST_WINDOW_1

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 53.82 33.26 20.56 50.97 66.25 0.00 0.00 0.00
February 71.08 45.01 26.08 69.94 68.24 0.00 0.00 0.00
March 84.81 49.63 35.18 89.05 51.61 0.00 0.00 0.00
April 85.72 41.92 43.80 87.98 44.53 0.00 0.00 0.00
May 99.32 41.61 57.71 114.41 28.45 0.00 0.00 0.00
June 121.46 63.29 58.17 159.43 18.70 0.00 0.00 0.00
July 109.95 52.19 57.76 144.46 18.43 0.00 0.00 0.00
August 111.56 61.00 50.56 145.36 21.69 0.00 0.00 0.00
September 93.80 50.95 42.85 116.14 31.28 0.00 0.00 0.00
October 68.64 37.72 30.92 71.75 59.47 0.00 0.00 0.00
November 53.81 30.49 23.32 52.06 65.44 0.00 0.00 0.00
December 46.97 27.34 19.62 42.37 78.36 0.00 0.00 0.00
                 
Annual Sum or Average 83.46 44.51 38.95 95.44 45.92 0.00 0.00 0.00
Minimum of Months 46.97 27.34 19.62 42.37 18.43 0.00 0.00 0.00
Maximum of Months 121.46 63.29 58.17 159.43 78.36 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_1

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 17.00 0.00 17.00 5.07 69.53 0.00 0.00 0.00
February 21.44 0.00 21.44 6.56 70.09 0.00 0.00 0.00
March 28.90 0.00 28.90 17.00 52.35 0.00 0.00 0.00
April 35.96 0.20 35.76 23.99 44.46 0.00 0.00 0.00
May 49.01 1.57 47.44 48.63 27.35 0.00 0.00 0.00
June 54.07 5.73 48.34 71.27 17.89 0.00 0.00 0.00
July 50.95 3.20 47.75 67.15 17.49 0.00 0.00 0.00
August 41.17 0.95 40.22 51.91 20.54 0.00 0.00 0.00
September 34.44 0.01 34.44 38.58 31.12 0.00 0.00 0.00
October 24.74 0.00 24.74 14.95 58.85 0.00 0.00 0.00
November 18.83 0.00 18.83 7.17 66.21 0.00 0.00 0.00
December 15.85 0.00 15.85 4.07 81.54 0.00 0.00 0.00
                 
Annual Sum or Average 32.76 0.97 31.78 29.82 46.33 0.00 0.00 0.00
Minimum of Months 15.85 0.00 15.85 4.07 17.49 0.00 0.00 0.00
Maximum of Months 54.07 5.73 48.34 71.27 81.54 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_2

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 17.00 0.00 17.00 5.06 69.53 0.00 0.00 0.00
February 21.44 0.00 21.44 6.56 70.09 0.00 0.00 0.00
March 28.90 0.00 28.90 17.00 52.35 0.00 0.00 0.00
April 35.92 0.19 35.73 23.97 44.52 0.00 0.00 0.00
May 48.85 1.51 47.33 48.34 27.36 0.00 0.00 0.00
June 53.89 5.64 48.24 70.91 17.89 0.00 0.00 0.00
July 50.78 3.12 47.65 66.82 17.49 0.00 0.00 0.00
August 41.03 0.90 40.13 51.65 20.54 0.00 0.00 0.00
September 34.44 0.01 34.43 38.58 31.12 0.00 0.00 0.00
October 24.73 0.00 24.73 14.95 58.85 0.00 0.00 0.00
November 18.83 0.00 18.83 7.16 66.21 0.00 0.00 0.00
December 15.85 0.00 15.85 4.07 81.54 0.00 0.00 0.00
                 
Annual Sum or Average 32.70 0.95 31.75 29.72 46.33 0.00 0.00 0.00
Minimum of Months 15.85 0.00 15.85 4.07 17.49 0.00 0.00 0.00
Maximum of Months 53.89 5.64 48.24 70.91 81.54 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_3

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 17.00 0.00 17.00 5.06 69.53 0.00 0.00 0.00
February 21.44 0.00 21.44 6.56 70.09 0.00 0.00 0.00
March 28.90 0.00 28.90 17.00 52.35 0.00 0.00 0.00
April 35.91 0.19 35.72 23.96 44.54 0.00 0.00 0.00
May 48.85 1.51 47.33 48.34 27.36 0.00 0.00 0.00
June 53.89 5.64 48.24 70.91 17.89 0.00 0.00 0.00
July 50.78 3.12 47.65 66.82 17.49 0.00 0.00 0.00
August 41.03 0.90 40.13 51.65 20.54 0.00 0.00 0.00
September 34.44 0.01 34.43 38.58 31.12 0.00 0.00 0.00
October 24.73 0.00 24.73 14.95 58.85 0.00 0.00 0.00
November 18.83 0.00 18.83 7.16 66.21 0.00 0.00 0.00
December 15.85 0.00 15.85 4.07 81.54 0.00 0.00 0.00
                 
Annual Sum or Average 32.69 0.95 31.74 29.72 46.34 0.00 0.00 0.00
Minimum of Months 15.85 0.00 15.85 4.07 17.49 0.00 0.00 0.00
Maximum of Months 53.89 5.64 48.24 70.91 81.54 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_4

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 17.00 0.00 17.00 5.06 69.53 0.00 0.00 0.00
February 21.44 0.00 21.44 6.56 70.09 0.00 0.00 0.00
March 28.90 0.00 28.90 17.00 52.35 0.00 0.00 0.00
April 35.91 0.19 35.72 23.96 44.54 0.00 0.00 0.00
May 48.85 1.51 47.33 48.34 27.36 0.00 0.00 0.00
June 53.89 5.64 48.24 70.91 17.89 0.00 0.00 0.00
July 50.78 3.12 47.65 66.82 17.49 0.00 0.00 0.00
August 41.03 0.90 40.13 51.65 20.54 0.00 0.00 0.00
September 34.44 0.01 34.43 38.58 31.13 0.00 0.00 0.00
October 24.73 0.00 24.73 14.95 58.85 0.00 0.00 0.00
November 18.83 0.00 18.83 7.16 66.21 0.00 0.00 0.00
December 15.85 0.00 15.85 4.07 81.54 0.00 0.00 0.00
                 
Annual Sum or Average 32.69 0.95 31.74 29.72 46.34 0.00 0.00 0.00
Minimum of Months 15.85 0.00 15.85 4.07 17.49 0.00 0.00 0.00
Maximum of Months 53.89 5.64 48.24 70.91 81.54 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_5

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 17.00 0.00 17.00 5.06 69.53 0.00 0.00 0.00
February 21.44 0.00 21.44 6.56 70.09 0.00 0.00 0.00
March 28.90 0.00 28.90 17.00 52.35 0.00 0.00 0.00
April 35.91 0.19 35.72 23.97 44.54 0.00 0.00 0.00
May 48.85 1.51 47.33 48.34 27.36 0.00 0.00 0.00
June 53.89 5.64 48.24 70.91 17.89 0.00 0.00 0.00
July 50.78 3.12 47.65 66.82 17.49 0.00 0.00 0.00
August 41.03 0.90 40.13 51.65 20.54 0.00 0.00 0.00
September 34.44 0.01 34.43 38.59 31.13 0.00 0.00 0.00
October 24.73 0.00 24.73 14.95 58.85 0.00 0.00 0.00
November 18.83 0.00 18.83 7.16 66.21 0.00 0.00 0.00
December 15.85 0.00 15.85 4.07 81.54 0.00 0.00 0.00
                 
Annual Sum or Average 32.69 0.95 31.74 29.72 46.34 0.00 0.00 0.00
Minimum of Months 15.85 0.00 15.85 4.07 17.49 0.00 0.00 0.00
Maximum of Months 53.89 5.64 48.24 70.91 81.54 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_6

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 17.00 0.00 17.00 5.07 69.53 0.00 0.00 0.00
February 21.44 0.00 21.44 6.56 70.09 0.00 0.00 0.00
March 28.90 0.00 28.90 17.00 52.35 0.00 0.00 0.00
April 35.94 0.20 35.74 23.99 44.51 0.00 0.00 0.00
May 48.98 1.55 47.43 48.56 27.36 0.00 0.00 0.00
June 54.04 5.71 48.33 71.20 17.89 0.00 0.00 0.00
July 50.90 3.16 47.74 67.03 17.50 0.00 0.00 0.00
August 41.12 0.94 40.18 51.82 20.54 0.00 0.00 0.00
September 34.44 0.01 34.44 38.59 31.13 0.00 0.00 0.00
October 24.74 0.00 24.74 14.95 58.85 0.00 0.00 0.00
November 18.83 0.00 18.83 7.17 66.21 0.00 0.00 0.00
December 15.85 0.00 15.85 4.07 81.54 0.00 0.00 0.00
                 
Annual Sum or Average 32.74 0.97 31.77 29.80 46.33 0.00 0.00 0.00
Minimum of Months 15.85 0.00 15.85 4.07 17.50 0.00 0.00 0.00
Maximum of Months 54.04 5.71 48.33 71.20 81.54 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_4_WALL_WEST_WINDOW_4

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 57.32 36.64 20.68 57.51 68.68 0.00 0.00 0.00
February 68.50 42.57 25.93 67.38 69.71 0.00 0.00 0.00
March 79.27 43.91 35.36 82.25 53.06 0.00 0.00 0.00
April 73.09 30.92 42.16 72.51 46.03 0.00 0.00 0.00
May 88.49 30.94 57.55 102.02 30.25 0.00 0.00 0.00
June 108.85 51.66 57.19 144.55 21.49 0.00 0.00 0.00
July 88.17 31.94 56.23 116.94 19.95 0.00 0.00 0.00
August 93.38 45.71 47.67 121.78 23.21 0.00 0.00 0.00
September 83.34 39.91 43.43 104.12 33.75 0.00 0.00 0.00
October 71.11 40.78 30.33 76.37 61.17 0.00 0.00 0.00
November 59.07 36.11 22.96 59.41 67.06 0.00 0.00 0.00
December 47.89 28.60 19.29 44.00 79.15 0.00 0.00 0.00
                 
Annual Sum or Average 76.56 38.26 38.30 87.48 47.67 0.00 0.00 0.00
Minimum of Months 47.89 28.60 19.29 44.00 19.95 0.00 0.00 0.00
Maximum of Months 108.85 51.66 57.55 144.55 79.15 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_4_WALL_WEST_WINDOW_3

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 57.20 36.56 20.64 57.29 68.71 0.00 0.00 0.00
February 68.46 42.54 25.92 67.30 69.73 0.00 0.00 0.00
March 79.26 43.90 35.36 82.25 53.06 0.00 0.00 0.00
April 73.08 30.92 42.16 72.51 46.03 0.00 0.00 0.00
May 88.49 30.94 57.55 102.02 30.25 0.00 0.00 0.00
June 108.85 51.66 57.19 144.55 21.49 0.00 0.00 0.00
July 88.16 31.94 56.23 116.93 19.95 0.00 0.00 0.00
August 93.37 45.71 47.67 121.78 23.21 0.00 0.00 0.00
September 83.34 39.90 43.43 104.12 33.75 0.00 0.00 0.00
October 71.10 40.77 30.33 76.35 61.16 0.00 0.00 0.00
November 58.98 36.05 22.92 59.24 67.08 0.00 0.00 0.00
December 47.77 28.53 19.25 43.79 79.19 0.00 0.00 0.00
                 
Annual Sum or Average 76.52 38.24 38.29 87.42 47.68 0.00 0.00 0.00
Minimum of Months 47.77 28.53 19.25 43.79 19.95 0.00 0.00 0.00
Maximum of Months 108.85 51.66 57.55 144.55 79.19 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_4_WALL_WEST_WINDOW_2

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 57.20 36.56 20.64 57.29 68.71 0.00 0.00 0.00
February 68.46 42.54 25.92 67.30 69.73 0.00 0.00 0.00
March 79.26 43.90 35.36 82.25 53.06 0.00 0.00 0.00
April 73.08 30.92 42.16 72.51 46.03 0.00 0.00 0.00
May 88.49 30.94 57.55 102.02 30.25 0.00 0.00 0.00
June 108.85 51.66 57.19 144.55 21.49 0.00 0.00 0.00
July 88.16 31.94 56.23 116.93 19.95 0.00 0.00 0.00
August 93.37 45.71 47.67 121.78 23.21 0.00 0.00 0.00
September 83.34 39.90 43.43 104.12 33.75 0.00 0.00 0.00
October 71.10 40.77 30.33 76.35 61.16 0.00 0.00 0.00
November 58.98 36.05 22.92 59.24 67.08 0.00 0.00 0.00
December 47.77 28.53 19.25 43.79 79.19 0.00 0.00 0.00
                 
Annual Sum or Average 76.52 38.24 38.29 87.42 47.68 0.00 0.00 0.00
Minimum of Months 47.77 28.53 19.25 43.79 19.95 0.00 0.00 0.00
Maximum of Months 108.85 51.66 57.55 144.55 79.19 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_4_WALL_WEST_WINDOW_1

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 57.20 36.56 20.64 57.29 68.71 0.00 0.00 0.00
February 68.46 42.54 25.92 67.30 69.73 0.00 0.00 0.00
March 79.27 43.90 35.36 82.25 53.06 0.00 0.00 0.00
April 73.09 30.92 42.16 72.51 46.03 0.00 0.00 0.00
May 88.49 30.94 57.55 102.02 30.25 0.00 0.00 0.00
June 108.85 51.66 57.19 144.55 21.49 0.00 0.00 0.00
July 88.17 31.94 56.23 116.94 19.95 0.00 0.00 0.00
August 93.38 45.71 47.67 121.78 23.21 0.00 0.00 0.00
September 83.34 39.90 43.43 104.12 33.75 0.00 0.00 0.00
October 71.10 40.77 30.33 76.35 61.17 0.00 0.00 0.00
November 58.98 36.05 22.93 59.24 67.08 0.00 0.00 0.00
December 47.77 28.53 19.25 43.79 79.19 0.00 0.00 0.00
                 
Annual Sum or Average 76.52 38.24 38.29 87.42 47.68 0.00 0.00 0.00
Minimum of Months 47.77 28.53 19.25 43.79 19.95 0.00 0.00 0.00
Maximum of Months 108.85 51.66 57.55 144.55 79.19 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.452421E+09 0.373698E+09 78722714.52 0.525943E+09 0.185456E+09
February 0.391628E+09 0.313782E+09 77845452.59 0.452547E+09 0.171674E+09
March 0.311326E+09 0.205767E+09 0.105560E+09 0.365532E+09 0.147215E+09
April 0.163533E+09 56083010.82 0.107450E+09 0.166281E+09 0.123428E+09
May 0.139790E+09 9936045.39 0.129854E+09 0.148350E+09 80429186.92
June 0.119765E+09 1401646.25 0.118364E+09 0.156588E+09 50441624.82
July 0.131515E+09 5945593.82 0.125569E+09 0.174590E+09 50628396.64
August 0.174210E+09 55483306.36 0.118726E+09 0.237800E+09 60403699.77
September 0.258348E+09 0.139392E+09 0.118956E+09 0.341787E+09 89351800.27
October 0.355629E+09 0.254323E+09 0.101305E+09 0.428662E+09 0.170185E+09
November 0.420703E+09 0.336894E+09 83809393.36 0.495012E+09 0.179959E+09
December 0.415724E+09 0.338009E+09 77715352.75 0.472823E+09 0.211213E+09
           
Annual Sum or Average 0.333459E+10 0.209071E+10 0.124388E+10 0.396592E+10 0.152039E+10
Minimum of Months 0.119765E+09 1401646.25 77715352.75 0.148350E+09 50441624.82
Maximum of Months 0.452421E+09 0.373698E+09 0.129854E+09 0.525943E+09 0.211213E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.452419E+09 0.373698E+09 78720658.68 0.525941E+09 0.185455E+09
February 0.391626E+09 0.313782E+09 77843305.47 0.452546E+09 0.171673E+09
March 0.311322E+09 0.205767E+09 0.105556E+09 0.365529E+09 0.147215E+09
April 0.163151E+09 55923313.60 0.107228E+09 0.165622E+09 0.123482E+09
May 0.139694E+09 9913301.56 0.129781E+09 0.148186E+09 80428484.01
June 0.119754E+09 1399966.26 0.118354E+09 0.156571E+09 50440429.06
July 0.131475E+09 5934160.28 0.125541E+09 0.174525E+09 50627434.28
August 0.173917E+09 55347041.40 0.118570E+09 0.237241E+09 60406569.79
September 0.258063E+09 0.139276E+09 0.118787E+09 0.341303E+09 89398915.05
October 0.355626E+09 0.254323E+09 0.101302E+09 0.428660E+09 0.170184E+09
November 0.420701E+09 0.336894E+09 83807273.10 0.495011E+09 0.179958E+09
December 0.415722E+09 0.338009E+09 77713271.26 0.472822E+09 0.211211E+09
           
Annual Sum or Average 0.333347E+10 0.209027E+10 0.124320E+10 0.396396E+10 0.152048E+10
Minimum of Months 0.119754E+09 1399966.26 77713271.26 0.148186E+09 50440429.06
Maximum of Months 0.452419E+09 0.373698E+09 0.129781E+09 0.525941E+09 0.211211E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.452419E+09 0.373698E+09 78720658.68 0.525941E+09 0.185455E+09
February 0.391626E+09 0.313782E+09 77843305.47 0.452546E+09 0.171673E+09
March 0.311322E+09 0.205767E+09 0.105556E+09 0.365529E+09 0.147215E+09
April 0.163150E+09 55923289.27 0.107227E+09 0.165621E+09 0.123483E+09
May 0.139694E+09 9913301.56 0.129781E+09 0.148186E+09 80428484.01
June 0.119754E+09 1399966.26 0.118354E+09 0.156571E+09 50440429.06
July 0.131475E+09 5934160.28 0.125541E+09 0.174525E+09 50627434.28
August 0.173916E+09 55346478.27 0.118570E+09 0.237240E+09 60406905.17
September 0.258025E+09 0.139270E+09 0.118756E+09 0.341277E+09 89436224.19
October 0.355626E+09 0.254323E+09 0.101302E+09 0.428660E+09 0.170184E+09
November 0.420701E+09 0.336894E+09 83807273.10 0.495011E+09 0.179958E+09
December 0.415722E+09 0.338009E+09 77713271.26 0.472822E+09 0.211211E+09
           
Annual Sum or Average 0.333343E+10 0.209026E+10 0.124317E+10 0.396393E+10 0.152052E+10
Minimum of Months 0.119754E+09 1399966.26 77713271.26 0.148186E+09 50440429.06
Maximum of Months 0.452419E+09 0.373698E+09 0.129781E+09 0.525941E+09 0.211211E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.452419E+09 0.373698E+09 78720658.68 0.525941E+09 0.185455E+09
February 0.391626E+09 0.313782E+09 77843305.47 0.452546E+09 0.171673E+09
March 0.311322E+09 0.205767E+09 0.105556E+09 0.365529E+09 0.147215E+09
April 0.163150E+09 55923289.27 0.107227E+09 0.165621E+09 0.123483E+09
May 0.139694E+09 9913301.56 0.129781E+09 0.148186E+09 80428484.01
June 0.119754E+09 1399966.26 0.118354E+09 0.156571E+09 50440429.06
July 0.131475E+09 5934160.28 0.125541E+09 0.174525E+09 50627434.28
August 0.173916E+09 55346569.63 0.118570E+09 0.237240E+09 60406638.63
September 0.258030E+09 0.139270E+09 0.118761E+09 0.341274E+09 89426303.65
October 0.355626E+09 0.254323E+09 0.101302E+09 0.428660E+09 0.170184E+09
November 0.420701E+09 0.336894E+09 83807273.10 0.495011E+09 0.179958E+09
December 0.415722E+09 0.338009E+09 77713271.26 0.472822E+09 0.211211E+09
           
Annual Sum or Average 0.333343E+10 0.209026E+10 0.124317E+10 0.396393E+10 0.152051E+10
Minimum of Months 0.119754E+09 1399966.26 77713271.26 0.148186E+09 50440429.06
Maximum of Months 0.452419E+09 0.373698E+09 0.129781E+09 0.525941E+09 0.211211E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.452419E+09 0.373698E+09 78720658.68 0.525941E+09 0.185455E+09
February 0.391626E+09 0.313782E+09 77843305.47 0.452546E+09 0.171673E+09
March 0.311322E+09 0.205767E+09 0.105556E+09 0.365529E+09 0.147215E+09
April 0.163151E+09 55923326.42 0.107228E+09 0.165621E+09 0.123481E+09
May 0.139694E+09 9913301.56 0.129781E+09 0.148186E+09 80428484.01
June 0.119754E+09 1399966.26 0.118354E+09 0.156571E+09 50440429.06
July 0.131475E+09 5934160.28 0.125541E+09 0.174525E+09 50627434.28
August 0.173918E+09 55347838.20 0.118570E+09 0.237242E+09 60405112.98
September 0.258077E+09 0.139277E+09 0.118800E+09 0.341276E+09 89351283.73
October 0.355626E+09 0.254323E+09 0.101302E+09 0.428660E+09 0.170184E+09
November 0.420701E+09 0.336894E+09 83807273.10 0.495011E+09 0.179958E+09
December 0.415722E+09 0.338009E+09 77713271.26 0.472822E+09 0.211211E+09
           
Annual Sum or Average 0.333348E+10 0.209027E+10 0.124322E+10 0.396393E+10 0.152043E+10
Minimum of Months 0.119754E+09 1399966.26 77713271.26 0.148186E+09 50440429.06
Maximum of Months 0.452419E+09 0.373698E+09 0.129781E+09 0.525941E+09 0.211211E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.452421E+09 0.373698E+09 78722714.42 0.525943E+09 0.185456E+09
February 0.391628E+09 0.313782E+09 77845452.48 0.452547E+09 0.171674E+09
March 0.311326E+09 0.205767E+09 0.105560E+09 0.365532E+09 0.147215E+09
April 0.163675E+09 56157242.37 0.107518E+09 0.166441E+09 0.123298E+09
May 0.139792E+09 9940568.76 0.129852E+09 0.148353E+09 80424395.49
June 0.119766E+09 1401909.76 0.118364E+09 0.156590E+09 50441624.75
July 0.131518E+09 5949307.54 0.125569E+09 0.174603E+09 50628396.59
August 0.174323E+09 55544908.35 0.118778E+09 0.238033E+09 60405292.83
September 0.258401E+09 0.139424E+09 0.118977E+09 0.341644E+09 89111971.89
October 0.355629E+09 0.254323E+09 0.101305E+09 0.428662E+09 0.170185E+09
November 0.420703E+09 0.336894E+09 83809393.25 0.495012E+09 0.179959E+09
December 0.415724E+09 0.338009E+09 77715352.64 0.472823E+09 0.211213E+09
           
Annual Sum or Average 0.333491E+10 0.209089E+10 0.124402E+10 0.396618E+10 0.152001E+10
Minimum of Months 0.119766E+09 1401909.76 77715352.64 0.148353E+09 50441624.75
Maximum of Months 0.452421E+09 0.373698E+09 0.129852E+09 0.525943E+09 0.211213E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_DOOR

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.635137E+09 0.523556E+09 0.111582E+09 0.737931E+09 0.258748E+09
February 0.550023E+09 0.439613E+09 0.110410E+09 0.635227E+09 0.239002E+09
March 0.447497E+09 0.296136E+09 0.151360E+09 0.526565E+09 0.204583E+09
April 0.265050E+09 0.103747E+09 0.161303E+09 0.285895E+09 0.170905E+09
May 0.227556E+09 29760609.62 0.197796E+09 0.257460E+09 0.112261E+09
June 0.192943E+09 16870268.10 0.176073E+09 0.261084E+09 71003477.09
July 0.213620E+09 23830238.50 0.189790E+09 0.291699E+09 71100605.61
August 0.290433E+09 0.111884E+09 0.178549E+09 0.406010E+09 84848984.69
September 0.402535E+09 0.226227E+09 0.176308E+09 0.537591E+09 0.125131E+09
October 0.500188E+09 0.356310E+09 0.143878E+09 0.601587E+09 0.236932E+09
November 0.590741E+09 0.471992E+09 0.118748E+09 0.694536E+09 0.250829E+09
December 0.583741E+09 0.473555E+09 0.110186E+09 0.663603E+09 0.294173E+09
           
Annual Sum or Average 0.489946E+10 0.307348E+10 0.182598E+10 0.589919E+10 0.211952E+10
Minimum of Months 0.192943E+09 16870268.10 0.110186E+09 0.257460E+09 71003477.09
Maximum of Months 0.635137E+09 0.523556E+09 0.197796E+09 0.737931E+09 0.294173E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_2_WALL_EAST_WINDOW_4

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.143842E+09 88886905.83 54955303.71 0.135994E+09 0.177560E+09
February 0.171868E+09 0.108811E+09 63057025.79 0.169008E+09 0.165122E+09
March 0.227141E+09 0.132921E+09 94219756.85 0.238505E+09 0.138219E+09
April 0.222196E+09 0.108669E+09 0.113526E+09 0.228053E+09 0.115425E+09
May 0.266011E+09 0.111452E+09 0.154560E+09 0.306442E+09 76188421.99
June 0.314827E+09 0.164060E+09 0.150767E+09 0.413242E+09 48461788.13
July 0.294499E+09 0.139797E+09 0.154702E+09 0.386931E+09 49356302.47
August 0.298811E+09 0.163394E+09 0.135417E+09 0.389344E+09 58087802.27
September 0.243136E+09 0.132060E+09 0.111076E+09 0.301036E+09 81070362.67
October 0.183818E+09 0.101006E+09 82811649.61 0.192117E+09 0.159284E+09
November 0.139233E+09 78867935.27 60364921.82 0.134465E+09 0.169673E+09
December 0.125434E+09 73010110.89 52423622.88 0.112923E+09 0.210069E+09
           
Annual Sum or Average 0.263082E+10 0.140294E+10 0.122788E+10 0.300806E+10 0.144852E+10
Minimum of Months 0.125434E+09 73010110.89 52423622.88 0.112923E+09 48461788.13
Maximum of Months 0.314827E+09 0.164060E+09 0.154702E+09 0.413242E+09 0.210069E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_2_WALL_EAST_WINDOW_3

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.143840E+09 88886905.83 54953247.97 0.135993E+09 0.177559E+09
February 0.171866E+09 0.108811E+09 63054878.77 0.169007E+09 0.165121E+09
March 0.227137E+09 0.132921E+09 94215715.38 0.238502E+09 0.138219E+09
April 0.222190E+09 0.108669E+09 0.113520E+09 0.228048E+09 0.115425E+09
May 0.266004E+09 0.111452E+09 0.154552E+09 0.306434E+09 76187488.57
June 0.314822E+09 0.164060E+09 0.150762E+09 0.413237E+09 48460537.43
July 0.294492E+09 0.139797E+09 0.154695E+09 0.386924E+09 49355214.00
August 0.298806E+09 0.163394E+09 0.135413E+09 0.389339E+09 58086513.57
September 0.243131E+09 0.132060E+09 0.111072E+09 0.301031E+09 81068718.43
October 0.183815E+09 0.101006E+09 82808545.59 0.192115E+09 0.159283E+09
November 0.139231E+09 78867935.27 60362801.67 0.134463E+09 0.169672E+09
December 0.125432E+09 73010110.89 52421541.49 0.112922E+09 0.210068E+09
           
Annual Sum or Average 0.263077E+10 0.140294E+10 0.122783E+10 0.300802E+10 0.144850E+10
Minimum of Months 0.125432E+09 73010110.89 52421541.49 0.112922E+09 48460537.43
Maximum of Months 0.314822E+09 0.164060E+09 0.154695E+09 0.413237E+09 0.210068E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_2_WALL_EAST_WINDOW_2

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.143840E+09 88886905.83 54953247.97 0.135993E+09 0.177559E+09
February 0.171866E+09 0.108811E+09 63054878.77 0.169007E+09 0.165121E+09
March 0.227137E+09 0.132921E+09 94215715.38 0.238502E+09 0.138219E+09
April 0.222190E+09 0.108669E+09 0.113520E+09 0.228048E+09 0.115425E+09
May 0.266004E+09 0.111452E+09 0.154552E+09 0.306434E+09 76187488.57
June 0.314822E+09 0.164060E+09 0.150762E+09 0.413237E+09 48460537.43
July 0.294492E+09 0.139797E+09 0.154695E+09 0.386924E+09 49355214.00
August 0.298806E+09 0.163394E+09 0.135413E+09 0.389339E+09 58086513.57
September 0.243131E+09 0.132060E+09 0.111072E+09 0.301031E+09 81068718.43
October 0.183815E+09 0.101006E+09 82808545.59 0.192115E+09 0.159283E+09
November 0.139231E+09 78867935.27 60362801.67 0.134463E+09 0.169672E+09
December 0.125432E+09 73010110.89 52421541.49 0.112922E+09 0.210068E+09
           
Annual Sum or Average 0.263077E+10 0.140294E+10 0.122783E+10 0.300802E+10 0.144850E+10
Minimum of Months 0.125432E+09 73010110.89 52421541.49 0.112922E+09 48460537.43
Maximum of Months 0.314822E+09 0.164060E+09 0.154695E+09 0.413237E+09 0.210068E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_2_WALL_EAST_WINDOW_1

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.144140E+09 89079465.15 55060035.12 0.136516E+09 0.177452E+09
February 0.171966E+09 0.108884E+09 63082109.35 0.169193E+09 0.165093E+09
March 0.227146E+09 0.132924E+09 94222422.82 0.238515E+09 0.138219E+09
April 0.222196E+09 0.108669E+09 0.113526E+09 0.228053E+09 0.115425E+09
May 0.266011E+09 0.111452E+09 0.154560E+09 0.306442E+09 76188422.04
June 0.314827E+09 0.164060E+09 0.150767E+09 0.413242E+09 48461788.20
July 0.294499E+09 0.139797E+09 0.154702E+09 0.386931E+09 49356302.53
August 0.298811E+09 0.163394E+09 0.135417E+09 0.389344E+09 58087802.34
September 0.243138E+09 0.132061E+09 0.111078E+09 0.301040E+09 81070362.76
October 0.183846E+09 0.101025E+09 82820729.15 0.192175E+09 0.159283E+09
November 0.139480E+09 79033538.77 60446712.80 0.134950E+09 0.169630E+09
December 0.125793E+09 73232630.01 52560586.11 0.113495E+09 0.209891E+09
           
Annual Sum or Average 0.263185E+10 0.140361E+10 0.122824E+10 0.300990E+10 0.144816E+10
Minimum of Months 0.125793E+09 73232630.01 52560586.11 0.113495E+09 48461788.20
Maximum of Months 0.314827E+09 0.164060E+09 0.154702E+09 0.413242E+09 0.209891E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_1

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 45537175.22 0.00 45537175.22 13566766.63 0.186230E+09
February 51865211.22 0.00 51865211.22 15878257.48 0.169556E+09
March 77401034.05 0.00 77401034.05 45523619.43 0.140204E+09
April 93215960.44 521762.65 92694197.79 62171149.26 0.115248E+09
May 0.131264E+09 4211107.33 0.127053E+09 0.130238E+09 73256924.39
June 0.140152E+09 14864566.21 0.125287E+09 0.184742E+09 46367202.04
July 0.136467E+09 8563558.77 0.127903E+09 0.179852E+09 46857688.52
August 0.110275E+09 2549420.95 0.107725E+09 0.139032E+09 55004084.53
September 89280511.47 20659.42 89259852.05 0.100002E+09 80664364.76
October 66250564.75 0.00 66250564.75 40052983.00 0.157617E+09
November 48815450.08 0.00 48815450.08 18571696.54 0.171610E+09
December 42462488.91 0.00 42462488.91 10898647.69 0.218387E+09
           
Annual Sum or Average 0.103299E+10 30731075.34 0.100225E+10 0.940529E+09 0.146100E+10
Minimum of Months 42462488.91 0.00 42462488.91 10898647.69 46367202.04
Maximum of Months 0.140152E+09 14864566.21 0.127903E+09 0.184742E+09 0.218387E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_2

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 45535119.38 0.00 45535119.38 13565758.07 0.186229E+09
February 51863064.09 0.00 51863064.09 15877380.07 0.169555E+09
March 77396992.37 0.00 77396992.37 45520859.63 0.140204E+09
April 93099205.66 495569.42 92603636.24 62125819.68 0.115406E+09
May 0.130831E+09 4049653.68 0.126781E+09 0.129468E+09 73289113.35
June 0.139672E+09 14626377.44 0.125045E+09 0.183807E+09 46365920.83
July 0.135997E+09 8360146.61 0.127637E+09 0.178961E+09 46858586.88
August 0.109901E+09 2420558.62 0.107481E+09 0.138342E+09 55009258.32
September 89275480.04 20629.40 89254850.64 99997802.94 80664057.14
October 66247460.57 0.00 66247460.57 40051444.91 0.157616E+09
November 48813329.81 0.00 48813329.81 18570728.42 0.171609E+09
December 42460407.42 0.00 42460407.42 10898009.25 0.218385E+09
           
Annual Sum or Average 0.103109E+10 29972935.18 0.100112E+10 0.937186E+09 0.146119E+10
Minimum of Months 42460407.42 0.00 42460407.42 10898009.25 46365920.83
Maximum of Months 0.139672E+09 14626377.44 0.127637E+09 0.183807E+09 0.218385E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_3

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 45535119.38 0.00 45535119.38 13565758.07 0.186229E+09
February 51863064.09 0.00 51863064.09 15877380.07 0.169555E+09
March 77396992.37 0.00 77396992.37 45520859.63 0.140204E+09
April 93067629.41 488994.69 92578634.72 62116889.34 0.115453E+09
May 0.130831E+09 4049653.68 0.126781E+09 0.129468E+09 73289113.35
June 0.139672E+09 14626377.44 0.125045E+09 0.183807E+09 46365920.83
July 0.135997E+09 8360146.61 0.127637E+09 0.178961E+09 46858586.88
August 0.109898E+09 2420452.96 0.107478E+09 0.138344E+09 55015286.42
September 89272356.88 20187.06 89252169.82 0.100002E+09 80673550.88
October 66247460.57 0.00 66247460.57 40051444.91 0.157616E+09
November 48813329.81 0.00 48813329.81 18570728.42 0.171609E+09
December 42460407.42 0.00 42460407.42 10898009.25 0.218385E+09
           
Annual Sum or Average 0.103105E+10 29965812.44 0.100109E+10 0.937183E+09 0.146125E+10
Minimum of Months 42460407.42 0.00 42460407.42 10898009.25 46365920.83
Maximum of Months 0.139672E+09 14626377.44 0.127637E+09 0.183807E+09 0.218385E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_4

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 45535119.38 0.00 45535119.38 13565758.07 0.186229E+09
February 51863064.09 0.00 51863064.09 15877380.07 0.169555E+09
March 77396992.37 0.00 77396992.37 45520859.63 0.140204E+09
April 93067629.41 488994.69 92578634.72 62116889.34 0.115453E+09
May 0.130831E+09 4049653.68 0.126781E+09 0.129468E+09 73289113.35
June 0.139672E+09 14626377.44 0.125045E+09 0.183807E+09 46365920.83
July 0.135997E+09 8360146.61 0.127637E+09 0.178961E+09 46858586.88
August 0.109896E+09 2420392.38 0.107476E+09 0.138346E+09 55020800.89
September 89272649.05 20192.77 89252456.28 0.100009E+09 80680214.83
October 66247460.57 0.00 66247460.57 40051444.91 0.157616E+09
November 48813329.81 0.00 48813329.81 18570728.42 0.171609E+09
December 42460407.42 0.00 42460407.42 10898009.25 0.218385E+09
           
Annual Sum or Average 0.103105E+10 29965757.57 0.100109E+10 0.937192E+09 0.146127E+10
Minimum of Months 42460407.42 0.00 42460407.42 10898009.25 46365920.83
Maximum of Months 0.139672E+09 14626377.44 0.127637E+09 0.183807E+09 0.218385E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_5

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 45535119.38 0.00 45535119.38 13565758.07 0.186229E+09
February 51863064.09 0.00 51863064.09 15877380.07 0.169555E+09
March 77396992.37 0.00 77396992.37 45520859.63 0.140204E+09
April 93082904.78 493794.57 92589110.21 62130308.13 0.115437E+09
May 0.130831E+09 4049653.68 0.126781E+09 0.129468E+09 73289113.35
June 0.139672E+09 14626377.44 0.125045E+09 0.183807E+09 46365920.83
July 0.135997E+09 8360147.83 0.127637E+09 0.178961E+09 46858586.88
August 0.109895E+09 2420443.17 0.107475E+09 0.138349E+09 55024971.21
September 89275205.91 20535.53 89254670.38 0.100016E+09 80683301.05
October 66247460.57 0.00 66247460.57 40051444.91 0.157616E+09
November 48813329.81 0.00 48813329.81 18570728.42 0.171609E+09
December 42460407.42 0.00 42460407.42 10898009.25 0.218385E+09
           
Annual Sum or Average 0.103107E+10 29970952.23 0.100110E+10 0.937216E+09 0.146126E+10
Minimum of Months 42460407.42 0.00 42460407.42 10898009.25 46365920.83
Maximum of Months 0.139672E+09 14626377.44 0.127637E+09 0.183807E+09 0.218385E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_6

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 45537175.11 0.00 45537175.11 13566766.57 0.186230E+09
February 51865211.11 0.00 51865211.11 15878257.43 0.169556E+09
March 77401033.84 0.00 77401033.84 45523619.28 0.140204E+09
April 93145401.16 512935.61 92632465.55 62184103.90 0.115376E+09
May 0.131184E+09 4148560.06 0.127035E+09 0.130070E+09 73288586.00
June 0.140071E+09 14806761.96 0.125264E+09 0.184562E+09 46366704.94
July 0.136326E+09 8472619.47 0.127854E+09 0.179542E+09 46859272.21
August 0.110137E+09 2519577.34 0.107617E+09 0.138807E+09 55020469.51
September 89279782.17 20535.92 89259246.25 0.100022E+09 80685871.63
October 66250564.59 0.00 66250564.59 40052982.92 0.157617E+09
November 48815449.97 0.00 48815449.97 18571696.49 0.171610E+09
December 42462488.80 0.00 42462488.80 10898647.66 0.218387E+09
           
Annual Sum or Average 0.103248E+10 30480990.35 0.100199E+10 0.939680E+09 0.146120E+10
Minimum of Months 42462488.80 0.00 42462488.80 10898647.66 46366704.94
Maximum of Months 0.140071E+09 14806761.96 0.127854E+09 0.184562E+09 0.218387E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_4_WALL_WEST_WINDOW_4

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.153527E+09 98132182.84 55394320.80 0.154031E+09 0.183944E+09
February 0.165719E+09 0.102988E+09 62731408.82 0.163001E+09 0.168653E+09
March 0.212311E+09 0.117596E+09 94715161.40 0.220307E+09 0.142115E+09
April 0.189442E+09 80154657.82 0.109287E+09 0.187947E+09 0.119314E+09
May 0.237006E+09 82862447.23 0.154144E+09 0.273260E+09 81012727.38
June 0.282150E+09 0.133902E+09 0.148248E+09 0.374679E+09 55694874.37
July 0.236145E+09 85538928.35 0.150606E+09 0.313206E+09 53441337.06
August 0.250100E+09 0.122423E+09 0.127677E+09 0.326182E+09 62172509.48
September 0.216011E+09 0.103434E+09 0.112577E+09 0.269881E+09 87469857.39
October 0.190473E+09 0.109225E+09 81248123.83 0.204559E+09 0.163824E+09
November 0.153101E+09 93595032.67 59505883.68 0.153991E+09 0.173822E+09
December 0.128278E+09 76604192.17 51674155.16 0.117840E+09 0.211992E+09
           
Annual Sum or Average 0.241426E+10 0.120646E+10 0.120781E+10 0.275888E+10 0.150346E+10
Minimum of Months 0.128278E+09 76604192.17 51674155.16 0.117840E+09 53441337.06
Maximum of Months 0.282150E+09 0.133902E+09 0.154144E+09 0.374679E+09 0.211992E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_4_WALL_WEST_WINDOW_3

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.153202E+09 97925666.56 55276807.56 0.153439E+09 0.184034E+09
February 0.165615E+09 0.102912E+09 62703288.90 0.162812E+09 0.168688E+09
March 0.212303E+09 0.117595E+09 94707993.41 0.220297E+09 0.142115E+09
April 0.189436E+09 80154657.82 0.109281E+09 0.187942E+09 0.119314E+09
May 0.236999E+09 82862447.23 0.154136E+09 0.273252E+09 81011897.27
June 0.282145E+09 0.133902E+09 0.148243E+09 0.374674E+09 55693633.71
July 0.236138E+09 85538928.35 0.150600E+09 0.313199E+09 53440298.28
August 0.250095E+09 0.122423E+09 0.127672E+09 0.326177E+09 62171289.23
September 0.216005E+09 0.103433E+09 0.112572E+09 0.269873E+09 87468324.32
October 0.190438E+09 0.109204E+09 81234073.74 0.204492E+09 0.163824E+09
November 0.152872E+09 93451571.90 59420337.76 0.153552E+09 0.173860E+09
December 0.127954E+09 76402209.28 51551899.79 0.117279E+09 0.212108E+09
           
Annual Sum or Average 0.241320E+10 0.120580E+10 0.120740E+10 0.275699E+10 0.150373E+10
Minimum of Months 0.127954E+09 76402209.28 51551899.79 0.117279E+09 53440298.28
Maximum of Months 0.282145E+09 0.133902E+09 0.154136E+09 0.374674E+09 0.212108E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_4_WALL_WEST_WINDOW_2

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.153202E+09 97925666.56 55276807.56 0.153439E+09 0.184034E+09
February 0.165615E+09 0.102912E+09 62703288.90 0.162812E+09 0.168688E+09
March 0.212303E+09 0.117595E+09 94707993.41 0.220297E+09 0.142115E+09
April 0.189436E+09 80154657.82 0.109281E+09 0.187942E+09 0.119314E+09
May 0.236999E+09 82862447.23 0.154136E+09 0.273252E+09 81011897.27
June 0.282145E+09 0.133902E+09 0.148243E+09 0.374674E+09 55693633.71
July 0.236138E+09 85538928.35 0.150600E+09 0.313199E+09 53440298.28
August 0.250095E+09 0.122423E+09 0.127672E+09 0.326177E+09 62171289.23
September 0.216005E+09 0.103433E+09 0.112572E+09 0.269873E+09 87468324.32
October 0.190438E+09 0.109204E+09 81234073.74 0.204492E+09 0.163824E+09
November 0.152872E+09 93451571.90 59420337.76 0.153552E+09 0.173860E+09
December 0.127954E+09 76402209.28 51551899.79 0.117279E+09 0.212108E+09
           
Annual Sum or Average 0.241320E+10 0.120580E+10 0.120740E+10 0.275699E+10 0.150373E+10
Minimum of Months 0.127954E+09 76402209.28 51551899.79 0.117279E+09 53440298.28
Maximum of Months 0.282145E+09 0.133902E+09 0.154136E+09 0.374674E+09 0.212108E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_4_WALL_WEST_WINDOW_1

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.153205E+09 97925666.56 55278863.41 0.153440E+09 0.184035E+09
February 0.165617E+09 0.102912E+09 62705436.03 0.162813E+09 0.168689E+09
March 0.212307E+09 0.117595E+09 94712035.09 0.220300E+09 0.142115E+09
April 0.189442E+09 80154657.82 0.109287E+09 0.187947E+09 0.119314E+09
May 0.237006E+09 82862447.23 0.154144E+09 0.273260E+09 81012727.42
June 0.282150E+09 0.133902E+09 0.148248E+09 0.374679E+09 55694874.43
July 0.236145E+09 85538928.35 0.150606E+09 0.313206E+09 53441337.11
August 0.250100E+09 0.122423E+09 0.127677E+09 0.326182E+09 62172509.55
September 0.216009E+09 0.103433E+09 0.112576E+09 0.269878E+09 87469857.47
October 0.190441E+09 0.109204E+09 81237177.92 0.204493E+09 0.163825E+09
November 0.152874E+09 93451571.90 59422458.02 0.153553E+09 0.173860E+09
December 0.127956E+09 76402209.28 51553981.29 0.117280E+09 0.212109E+09
           
Annual Sum or Average 0.241325E+10 0.120580E+10 0.120745E+10 0.275703E+10 0.150374E+10
Minimum of Months 0.127956E+09 76402209.28 51553981.29 0.117280E+09 53441337.11
Maximum of Months 0.282150E+09 0.133902E+09 0.154144E+09 0.374679E+09 0.212109E+09



Table of Contents

Report: WindowZoneSummaryMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 1453.70 512.05 1250.62 1032.61 218.01 0.00 0.00
February 1384.96 524.57 1198.65 959.95 238.70 0.00 0.00
March 1015.43 406.16 864.49 571.51 292.97 0.00 0.00
April 494.20 351.63 480.27 169.63 310.64 0.00 0.00
May 428.20 222.08 397.97 33.34 364.63 0.00 0.00
June 463.17 144.15 351.65 9.75 341.90 0.00 0.00
July 499.92 139.96 374.31 22.20 352.11 0.00 0.00
August 683.54 166.99 498.29 165.88 332.41 0.00 0.00
September 997.72 255.08 752.89 409.77 343.11 0.00 0.00
October 1184.87 469.69 983.40 702.75 280.65 0.00 0.00
November 1413.81 513.34 1201.76 961.94 239.81 0.00 0.00
December 1306.95 582.98 1149.22 933.99 215.23 0.00 0.00
               
Annual Sum or Average 941.36 356.47 789.66 495.18 294.48 0.00 0.00
Minimum of Months 428.20 139.96 351.65 9.75 215.23 0.00 0.00
Maximum of Months 1453.70 582.98 1250.62 1032.61 364.63 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 203.28 265.12 214.93 132.82 82.11 0.00 0.00
February 279.52 273.01 284.21 179.94 104.27 0.00 0.00
March 356.19 206.42 339.22 198.51 140.71 0.00 0.00
April 351.93 178.13 342.89 167.70 175.19 0.00 0.00
May 457.64 113.78 397.26 166.45 230.82 0.00 0.00
June 637.72 74.79 485.84 253.18 232.66 0.00 0.00
July 577.85 73.71 439.81 208.78 231.03 0.00 0.00
August 581.45 86.75 446.25 244.02 202.23 0.00 0.00
September 464.56 125.11 375.21 203.80 171.41 0.00 0.00
October 286.93 237.88 274.53 150.85 123.67 0.00 0.00
November 207.69 261.82 214.96 121.77 93.19 0.00 0.00
December 168.84 313.64 187.46 109.12 78.34 0.00 0.00
               
Annual Sum or Average 381.59 183.71 333.72 177.97 155.75 0.00 0.00
Minimum of Months 168.84 73.71 187.46 109.12 78.34 0.00 0.00
Maximum of Months 637.72 313.64 485.84 253.18 232.66 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 30.39 417.18 102.01 0.00 102.01 0.00 0.00
February 39.38 420.52 128.63 0.00 128.63 0.00 0.00
March 101.98 314.08 173.38 0.00 173.38 0.00 0.00
April 143.84 267.11 215.54 1.16 214.38 0.00 0.00
May 290.54 164.17 293.37 9.17 284.20 0.00 0.00
June 426.13 107.33 323.65 34.02 289.63 0.00 0.00
July 401.45 104.97 304.95 18.85 286.11 0.00 0.00
August 310.34 123.24 246.42 5.51 240.91 0.00 0.00
September 231.50 186.75 206.66 0.05 206.61 0.00 0.00
October 89.72 353.08 148.41 0.00 148.41 0.00 0.00
November 42.99 397.24 113.00 0.00 113.00 0.00 0.00
December 24.41 489.22 95.12 0.00 95.12 0.00 0.00
               
Annual Sum or Average 178.49 278.00 196.27 5.74 190.53 0.00 0.00
Minimum of Months 24.41 104.97 95.12 0.00 95.12 0.00 0.00
Maximum of Months 426.13 489.22 323.65 34.02 289.63 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 229.36 274.79 228.92 146.32 82.60 0.00 0.00
February 269.28 278.90 273.88 170.19 103.69 0.00 0.00
March 329.00 212.24 317.06 175.62 141.44 0.00 0.00
April 290.04 184.13 292.34 123.70 168.65 0.00 0.00
May 408.09 120.99 353.95 123.75 230.20 0.00 0.00
June 578.20 85.95 435.41 206.64 228.77 0.00 0.00
July 467.75 79.81 352.66 127.75 224.91 0.00 0.00
August 487.13 92.85 373.50 182.83 190.67 0.00 0.00
September 416.48 134.98 333.34 159.62 173.73 0.00 0.00
October 305.42 244.66 284.42 163.10 121.32 0.00 0.00
November 237.13 268.28 236.00 144.27 91.73 0.00 0.00
December 175.35 316.72 191.21 114.18 77.04 0.00 0.00
               
Annual Sum or Average 349.75 190.72 306.12 152.96 153.16 0.00 0.00
Minimum of Months 175.35 79.81 191.21 114.18 77.04 0.00 0.00
Maximum of Months 578.20 316.72 435.41 206.64 230.20 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: ATTIC

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.389358E+10 0.137148E+10 0.334965E+10 0.276574E+10 0.583910E+09 0.00 0.00
February 0.335050E+10 0.126904E+10 0.289978E+10 0.232231E+10 0.577474E+09 0.00 0.00
March 0.271973E+10 0.108786E+10 0.231544E+10 0.153074E+10 0.784703E+09 0.00 0.00
April 0.128096E+10 0.911416E+09 0.124486E+10 0.439681E+09 0.805179E+09 0.00 0.00
May 0.114690E+10 0.594818E+09 0.106591E+10 89290430.02 0.976624E+09 0.00 0.00
June 0.120054E+10 0.373647E+09 0.911489E+09 25273689.17 0.886215E+09 0.00 0.00
July 0.133899E+10 0.374862E+09 0.100255E+10 59461780.96 0.943093E+09 0.00 0.00
August 0.183080E+10 0.447277E+09 0.133463E+10 0.444300E+09 0.890332E+09 0.00 0.00
September 0.258610E+10 0.661155E+09 0.195148E+10 0.106214E+10 0.889344E+09 0.00 0.00
October 0.317355E+10 0.125803E+10 0.263395E+10 0.188225E+10 0.751697E+09 0.00 0.00
November 0.366460E+10 0.133058E+10 0.311495E+10 0.249335E+10 0.621596E+09 0.00 0.00
December 0.350053E+10 0.156144E+10 0.307808E+10 0.250161E+10 0.576470E+09 0.00 0.00
               
Annual Sum or Average 0.296868E+11 0.112416E+11 0.249028E+11 0.156161E+11 0.928664E+10 0.00 0.00
Minimum of Months 0.114690E+10 0.373647E+09 0.911489E+09 25273689.17 0.576470E+09 0.00 0.00
Maximum of Months 0.389358E+10 0.156144E+10 0.334965E+10 0.276574E+10 0.976624E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.544473E+09 0.710107E+09 0.575662E+09 0.355740E+09 0.219922E+09 0.00 0.00
February 0.676215E+09 0.660456E+09 0.687566E+09 0.435317E+09 0.252249E+09 0.00 0.00
March 0.954024E+09 0.552875E+09 0.908562E+09 0.531688E+09 0.376874E+09 0.00 0.00
April 0.912202E+09 0.461700E+09 0.888771E+09 0.434678E+09 0.454093E+09 0.00 0.00
May 0.122575E+10 0.304752E+09 0.106403E+10 0.445807E+09 0.618223E+09 0.00 0.00
June 0.165296E+10 0.193845E+09 0.125930E+10 0.656240E+09 0.603058E+09 0.00 0.00
July 0.154771E+10 0.197423E+09 0.117798E+10 0.559188E+09 0.618794E+09 0.00 0.00
August 0.155737E+10 0.232349E+09 0.119523E+10 0.653575E+09 0.541660E+09 0.00 0.00
September 0.120414E+10 0.324278E+09 0.972537E+09 0.528239E+09 0.444298E+09 0.00 0.00
October 0.768522E+09 0.637133E+09 0.735293E+09 0.404044E+09 0.331249E+09 0.00 0.00
November 0.538338E+09 0.678643E+09 0.557175E+09 0.315637E+09 0.241537E+09 0.00 0.00
December 0.452225E+09 0.840059E+09 0.502090E+09 0.292263E+09 0.209827E+09 0.00 0.00
               
Annual Sum or Average 0.120339E+11 0.579362E+10 0.105242E+11 0.561242E+10 0.491178E+10 0.00 0.00
Minimum of Months 0.452225E+09 0.193845E+09 0.502090E+09 0.292263E+09 0.209827E+09 0.00 0.00
Maximum of Months 0.165296E+10 0.840059E+09 0.125930E+10 0.656240E+09 0.618794E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 81396562.29 0.111738E+10 0.273215E+09 0.00 0.273215E+09 0.00 0.00
February 95266035.19 0.101733E+10 0.311183E+09 0.00 0.311183E+09 0.00 0.00
March 0.273131E+09 0.841223E+09 0.464390E+09 0.00 0.464390E+09 0.00 0.00
April 0.372823E+09 0.692350E+09 0.558679E+09 3002051.62 0.555677E+09 0.00 0.00
May 0.778181E+09 0.439701E+09 0.785771E+09 24558282.12 0.761212E+09 0.00 0.00
June 0.110453E+10 0.278198E+09 0.838909E+09 88176837.94 0.750732E+09 0.00 0.00
July 0.107524E+10 0.281151E+09 0.816782E+09 50476765.91 0.766305E+09 0.00 0.00
August 0.831210E+09 0.330085E+09 0.660002E+09 14750845.43 0.645251E+09 0.00 0.00
September 0.600048E+09 0.484051E+09 0.535656E+09 122740.09 0.535533E+09 0.00 0.00
October 0.240312E+09 0.945699E+09 0.397491E+09 0.00 0.397491E+09 0.00 0.00
November 0.111426E+09 0.102966E+10 0.292884E+09 0.00 0.292884E+09 0.00 0.00
December 65389332.35 0.131031E+10 0.254767E+09 0.00 0.254767E+09 0.00 0.00
               
Annual Sum or Average 0.562895E+10 0.876714E+10 0.618973E+10 0.181088E+09 0.600864E+10 0.00 0.00
Minimum of Months 65389332.35 0.278198E+09 0.254767E+09 0.00 0.254767E+09 0.00 0.00
Maximum of Months 0.110453E+10 0.131031E+10 0.838909E+09 88176837.94 0.766305E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.614308E+09 0.736007E+09 0.613136E+09 0.391909E+09 0.221227E+09 0.00 0.00
February 0.651437E+09 0.674719E+09 0.662566E+09 0.411722E+09 0.250843E+09 0.00 0.00
March 0.881200E+09 0.568460E+09 0.849224E+09 0.470381E+09 0.378843E+09 0.00 0.00
April 0.751776E+09 0.477256E+09 0.757755E+09 0.320619E+09 0.437137E+09 0.00 0.00
May 0.109302E+10 0.324049E+09 0.948010E+09 0.331450E+09 0.616560E+09 0.00 0.00
June 0.149870E+10 0.222777E+09 0.112859E+10 0.535610E+09 0.592981E+09 0.00 0.00
July 0.125281E+10 0.213763E+09 0.944567E+09 0.342156E+09 0.602411E+09 0.00 0.00
August 0.130472E+10 0.248688E+09 0.100039E+10 0.489693E+09 0.510698E+09 0.00 0.00
September 0.107950E+10 0.349876E+09 0.864029E+09 0.413732E+09 0.450297E+09 0.00 0.00
October 0.818035E+09 0.655298E+09 0.761789E+09 0.436836E+09 0.324953E+09 0.00 0.00
November 0.614637E+09 0.695391E+09 0.611719E+09 0.373950E+09 0.237769E+09 0.00 0.00
December 0.469664E+09 0.848303E+09 0.512143E+09 0.305811E+09 0.206332E+09 0.00 0.00
               
Annual Sum or Average 0.110298E+11 0.601459E+10 0.965392E+10 0.482387E+10 0.483005E+10 0.00 0.00
Minimum of Months 0.469664E+09 0.213763E+09 0.512143E+09 0.305811E+09 0.206332E+09 0.00 0.00
Maximum of Months 0.149870E+10 0.848303E+09 0.112859E+10 0.535610E+09 0.616560E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: ATTIC

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AverageOutdoorConditionsMonthly

For: Environment

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] SITE OUTDOOR AIR WETBULB TEMPERATURE [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] SITE WIND SPEED [m/s] SITE SKY TEMPERATURE [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] SITE RAIN STATUS []
January 0.85 -1.5 -4.5 2.30 -12.1 27.63 226.20 0.01
February -0.2 -2.7 -6.1 3.74 -13.6 32.55 253.27 0.01
March 4.82 0.36 -5.5 4.48 -7.8 54.65 233.06 0.03
April 6.08 2.29 -2.0 5.23 -4.9 81.86 179.11 0.05
May 13.74 7.52 1.82 4.10 2.75 117.64 180.87 0.01
June 22.16 12.46 5.10 4.19 9.76 95.26 290.95 0.00
July 22.71 13.25 6.43 4.25 12.01 110.54 215.12 0.03
August 21.74 12.79 6.20 3.81 10.76 77.72 272.61 0.02
September 18.54 9.35 1.35 4.13 5.52 70.51 233.03 0.01
October 7.12 2.51 -2.7 3.54 -5.8 44.60 216.74 0.01
November 3.03 0.31 -2.9 2.79 -8.8 30.71 220.86 0.01
December -1.0 -4.5 -9.5 4.43 -15.4 27.45 194.75 0.01
                 
Annual Sum or Average 10.02 4.37 -1.0 3.91 -2.2 64.46 226.11 0.02
Minimum of Months -1.0 -4.5 -9.5 2.30 -15.4 27.45 179.11 0.00
Maximum of Months 22.71 13.25 6.43 5.23 12.01 117.64 290.95 0.05



Table of Contents

Report: OutdoorConditionsMaximumDryBulbMonthly

For: Environment

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] SITE WIND SPEED {AT MAX/MIN} [m/s] SITE SKY TEMPERATURE {AT MAX/MIN} [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2]
January 21.00 20-JAN-12:00 6.97 -11.0 0.50 6.55 41.00 961.00
February 20.00 18-FEB-12:00 7.74 -5.0 3.60 6.35 56.00 998.00
March 24.00 14-MAR-12:00 7.90 -12.0 3.10 11.65 160.00 837.50
April 22.00 19-APR-13:09 8.49 -5.7 5.52 11.55 235.67 789.67
May 29.00 17-MAY-12:00 11.92 -3.0 5.10 18.99 432.50 162.00
June 39.40 26-JUN-14:00 15.63 -2.8 4.60 21.96 136.50 752.00
July 37.00 16-JUL-12:00 14.90 -3.0 3.10 26.65 319.50 109.50
August 37.00 16-AUG-13:00 16.36 3.00 3.60 28.27 90.00 895.00
September 32.70 09-SEP-12:00 13.05 -3.9 3.00 16.30 270.50 562.00
October 27.00 11-OCT-13:00 9.73 -9.0 4.60 12.03 89.50 844.00
November 22.00 06-NOV-13:09 7.10 -13.0 2.60 4.92 88.67 883.33
December 22.00 01-DEC-13:00 7.94 -8.0 2.60 5.13 49.00 862.00
                 
Annual Sum or Average                
Minimum of Months 20.00   6.97 -13.0 0.50 4.92 41.00 109.50
Maximum of Months 39.40   16.36 3.00 5.52 28.27 432.50 998.00



Table of Contents

Report: OutdoorConditionsMinimumDryBulbMonthly

For: Environment

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] SITE WIND SPEED {AT MAX/MIN} [m/s] SITE SKY TEMPERATURE {AT MAX/MIN} [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2]
January -19.0 05-JAN-18:00 -19.0 -19.0 1.50 -37.1 0.00 0.00
February -20.0 12-FEB-04:00 -20.0 -20.0 3.60 -39.1 0.00 0.00
March -15.6 19-MAR-06:00 -15.6 -15.6 10.80 -25.3 24.00 0.00
April -8.0 03-APR-02:00 -8.0 -8.0 3.10 -22.2 0.00 0.00
May -1.0 03-MAY-01:00 -2.4 -4.0 4.10 -15.7 0.00 0.00
June 6.60 09-JUN-03:00 3.45 0.00 3.60 -6.9 0.00 0.00
July 9.00 02-JUL-04:00 3.30 -3.0 3.60 -5.3 20.00 184.50
August 11.00 12-AUG-22:00 7.22 4.00 4.10 5.13 0.00 0.00
September -1.7 22-SEP-05:10 -2.9 -4.3 3.60 -15.8 0.00 0.00
October -10.0 30-OCT-03:00 -10.0 -10.0 2.60 -18.6 0.00 0.00
November -15.0 29-NOV-20:00 -15.0 -15.0 3.10 -33.5 0.00 0.00
December -23.0 22-DEC-02:00 -23.0 -23.0 3.60 -42.7 0.00 0.00
                 
Annual Sum or Average                
Minimum of Months -23.0   -23.0 -23.0 1.50 -42.7 0.00 0.00
Maximum of Months 11.00   7.22 4.00 10.80 5.13 24.00 184.50



Table of Contents

Report: OutdoorConditionsMaximumWetBulbMonthly

For: Environment

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] SITE WIND SPEED {AT MAX/MIN} [m/s] SITE SKY TEMPERATURE {AT MAX/MIN} [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2]
January 7.55 20-JAN-11:00 20.00 -6.0 2.60 7.95 43.00 971.50
February 7.98 18-FEB-14:00 19.00 -3.0 3.60 5.94 151.00 410.00
March 8.00 31-MAR-17:00 15.00 2.00 2.60 1.58 19.50 261.00
April 12.50 28-APR-13:00 18.00 9.00 9.80 9.72 335.00 196.50
May 14.87 31-MAY-13:00 28.00 7.00 4.60 14.47 157.50 830.50
June 19.65 18-JUN-11:00 29.40 15.50 6.10 16.85 272.50 596.00
July 19.75 30-JUL-13:00 29.00 16.00 3.60 18.99 217.50 412.00
August 18.80 05-AUG-14:09 25.83 15.33 6.62 20.54 196.33 4.00
September 14.95 01-SEP-11:00 24.40 9.40 3.00 10.69 193.50 684.00
October 9.73 11-OCT-13:00 27.00 -9.0 4.60 12.03 89.50 844.00
November 9.33 09-NOV-10:00 20.00 0.00 1.50 11.07 112.00 860.50
December 7.94 01-DEC-13:00 22.00 -8.0 2.60 5.13 49.00 862.00
                 
Annual Sum or Average                
Minimum of Months 7.55   15.00 -9.0 1.50 1.58 19.50 4.00
Maximum of Months 19.75   29.40 16.00 9.80 20.54 335.00 971.50



Table of Contents

Report: OutdoorConditionsMaximumDewPointMonthly

For: Environment

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] SITE WIND SPEED {AT MAX/MIN} [m/s] SITE SKY TEMPERATURE {AT MAX/MIN} [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2]
January 5.00 28-JAN-10:00 5.00 5.00 1.00 -6.2 207.00 309.00
February 5.00 19-FEB-14:30 5.00 5.00 1.80 -0.4 188.00 467.00
March 7.00 17-MAR-14:00 8.00 7.39 8.20 1.16 121.50 3.00
April 9.00 28-APR-13:00 18.00 12.50 9.80 9.72 335.00 196.50
May 11.00 21-MAY-21:10 12.83 11.73 2.68 6.78 0.00 0.00
June 15.50 18-JUN-11:00 29.40 19.65 6.10 16.85 272.50 596.00
July 17.00 28-JUL-16:00 20.00 17.92 5.70 15.02 155.00 32.00
August 18.00 04-AUG-01:00 18.00 18.00 2.60 8.74 0.00 0.00
September 12.20 30-SEP-14:00 17.20 13.90 5.10 9.72 209.00 82.50
October 6.00 01-OCT-19:00 9.00 7.28 3.10 3.69 0.00 0.00
November 7.00 09-NOV-23:00 8.00 7.40 4.10 3.06 0.00 0.00
December 1.00 30-DEC-14:00 7.00 4.06 9.80 -1.2 101.00 91.50
                 
Annual Sum or Average                
Minimum of Months 1.00   5.00 4.06 1.00 -6.2 0.00 0.00
Maximum of Months 18.00   29.40 19.65 9.80 16.85 335.00 596.00



Table of Contents

Report: OutdoorGroundConditionsMonthly

For: Environment

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SITE GROUND TEMPERATURE [C] SITE SURFACE GROUND TEMPERATURE [C] SITE DEEP GROUND TEMPERATURE [C] SITE MAINS WATER TEMPERATURE [C] SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] SITE SNOW ON GROUND STATUS []
January 18.00 13.00 16.00 8.52 21.53 0.00
February 18.00 13.00 16.00 7.90 29.36 0.00
March 18.00 13.00 16.00 8.65 35.75 0.00
April 18.00 13.00 16.00 10.64 38.62 0.00
May 18.00 13.00 16.00 13.34 48.35 0.00
June 18.00 13.00 16.00 16.03 59.81 0.00
July 18.00 13.00 16.00 17.97 52.29 0.00
August 18.00 13.00 16.00 18.66 51.98 0.00
September 18.00 13.00 16.00 17.88 41.73 0.00
October 18.00 13.00 16.00 15.85 30.82 0.00
November 18.00 13.00 16.00 13.14 23.90 0.00
December 18.00 13.00 16.00 10.46 18.59 0.00
             
Annual Sum or Average 18.00 13.00 16.00 13.28 37.76 0.00
Minimum of Months 18.00 13.00 16.00 7.90 18.59 0.00
Maximum of Months 18.00 13.00 16.00 18.66 59.81 0.00



Table of Contents

Report: WaterHeaterReportMonthly

For: SWHSYS1 WATER HEATER

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] WATER HEATER BURNER HEATING ENERGY [] WATER HEATER GAS CONSUMPTION [] WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] WATER HEATER LOSS DEMAND ENERGY [] WATER HEATER HEAT LOSS ENERGY [J] WATER HEATER TANK TEMPERATURE [C] WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] WATER HEATER SOURCE ENERGY []
January 0.636865E+09 -513095127.8 0.00 0.00 744.00 0.00 -123769724.7 58.99 0.00 0.00
February 0.582019E+09 -469994219.6 0.00 0.00 672.00 0.00 -112024773.8 59.00 0.00 0.00
March 0.681010E+09 -560364973.7 0.00 0.00 744.00 0.00 -120644850.4 58.99 0.00 0.00
April 0.584130E+09 -468244144.8 0.00 0.00 720.00 0.00 -115885675.2 59.00 0.00 0.00
May 0.600599E+09 -487170699.1 0.00 0.00 744.00 0.00 -113428037.7 58.99 0.00 0.00
June 0.561490E+09 -457165579.4 0.00 0.00 720.00 0.00 -104324226.2 58.99 0.00 0.00
July 0.503183E+09 -396697938.7 0.00 0.00 744.00 0.00 -106485096.0 58.99 0.00 0.00
August 0.556203E+09 -449179496.6 0.00 0.00 744.00 0.00 -107023806.3 58.99 0.00 0.00
September 0.502791E+09 -398475408.3 0.00 0.00 720.00 0.00 -104315185.1 58.99 0.00 0.00
October 0.552471E+09 -438866784.4 0.00 0.00 744.00 0.00 -113604564.8 58.99 0.00 0.00
November 0.581554E+09 -466057477.6 0.00 0.00 720.00 0.00 -115496969.5 58.99 0.00 0.00
December 0.593428E+09 -469396953.2 0.00 0.00 744.00 0.00 -124031233.1 58.99 0.00 0.00
                     
Annual Sum or Average 0.693574E+10 -0.557471E+10 0.00 0.00 8760.00 0.00 -0.136103E+10 58.99 0.00 0.00
Minimum of Months 0.502791E+09 -560364973.7 0.00 0.00 672.00 0.00 -124031233.1 58.99 0.00 0.00
Maximum of Months 0.681010E+09 -396697938.7 0.00 0.00 744.00 0.00 -104315185.1 59.00 0.00 0.00



Table of Contents

Report: DaylightingReportMonthly

For: PERIMETER_ZN_1_DAYLCTRL

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 276.50 0.77 0.76 01-JAN-07:49 2393.40 28.31 150.17 249.17 4117.69 34.27 219.00 235.50
February 245.50 0.77 0.76 01-FEB-10:39 3346.66 27.72 129.50 222.17 1048.60 24.42 141.33 203.83
March 296.17 0.78 0.76 01-MAR-07:10 861.13 18.15 8.17 247.83 610.45 22.34 186.67 198.67
April 296.67 0.79 0.76 03-APR-09:50 552.96 17.97 0.00 210.17 423.27 22.29 217.67 155.17
May 415.33 0.80 0.76 01-MAY-07:40 479.93 17.87 0.00 281.67 350.90 22.19 295.17 204.83
June 421.50 0.80 0.76 01-JUN-06:30 393.16 17.26 0.00 246.83 294.12 21.67 279.50 132.50
July 430.33 0.80 0.76 01-JUL-10:30 437.93 17.45 0.00 266.83 322.42 21.78 287.33 180.67
August 394.50 0.80 0.76 01-AUG-06:40 484.65 17.48 0.00 258.50 373.39 21.79 269.17 189.67
September 354.00 0.79 0.76 01-SEP-07:19 882.20 18.78 17.00 265.00 505.45 22.34 245.33 226.33
October 262.67 0.77 0.76 01-OCT-06:40 4397.58 27.94 137.17 238.00 772.93 23.05 208.33 202.83
November 257.67 0.77 0.76 01-NOV-08:39 2521.94 27.91 135.17 230.33 1368.64 26.08 176.00 215.83
December 251.17 0.77 0.76 01-DEC-07:49 1620.75 26.28 109.67 225.67 3441.24 33.54 195.33 213.67
                         
Annual Sum or Average 3902.00 0.79     1325.33 21.07 686.83 2942.17 988.48 24.12 2720.83 2359.50
Minimum of Months 245.50 0.77 0.76   393.16 17.26 0.00 210.17 294.12 21.67 141.33 132.50
Maximum of Months 430.33 0.80 0.76   4397.58 28.31 150.17 281.67 4117.69 34.27 295.17 235.50



Table of Contents

Report: DaylightingReportMonthly

For: PERIMETER_ZN_2_DAYLCTRL

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 276.50 0.84 0.76 01-JAN-07:00 1619.33 22.33 99.17 109.83 407.62 19.13 60.33 78.50
February 245.50 0.83 0.76 01-FEB-10:39 1577.29 20.43 53.00 94.83 1588.96 21.50 69.33 82.83
March 296.17 0.82 0.76 01-MAR-07:19 517.20 17.28 25.17 131.50 460.21 16.97 18.33 100.33
April 296.67 0.81 0.76 03-APR-09:50 487.83 17.19 25.67 154.33 413.35 16.74 7.33 108.33
May 415.33 0.81 0.76 01-MAY-06:19 467.49 17.12 10.67 221.83 393.40 16.54 0.33 159.00
June 421.50 0.81 0.76 01-JUN-05:30 471.90 16.27 1.50 198.83 448.88 16.05 0.00 169.33
July 430.33 0.81 0.76 01-JUL-05:40 465.95 16.62 4.00 223.67 402.80 16.14 0.67 163.67
August 394.50 0.82 0.76 01-AUG-05:00 486.85 16.58 13.17 197.00 428.75 16.26 2.67 152.67
September 354.00 0.82 0.76 01-SEP-05:00 543.28 17.47 38.83 175.67 434.17 17.06 22.17 129.67
October 262.67 0.82 0.76 01-OCT-06:40 1508.99 20.72 67.50 117.17 1040.74 20.32 67.33 90.00
November 257.67 0.84 0.76 01-NOV-08:39 1235.16 20.91 76.67 107.00 629.54 20.12 75.50 83.17
December 251.17 0.84 0.76 01-DEC-07:00 1613.24 23.35 94.17 98.50 432.56 19.91 67.17 71.50
                         
Annual Sum or Average 3902.00 0.82     827.95 18.44 509.50 1830.17 552.21 17.71 391.17 1389.00
Minimum of Months 245.50 0.81 0.76   465.95 16.27 1.50 94.83 393.40 16.05 0.00 71.50
Maximum of Months 430.33 0.84 0.76   1619.33 23.35 99.17 223.67 1588.96 21.50 75.50 169.33



Table of Contents

Report: DaylightingReportMonthly

For: PERIMETER_ZN_3_DAYLCTRL

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 276.50 0.92 0.81 30-JAN-12:30 133.47 0.00 0.00 0.00 105.31 0.00 0.00 0.00
February 245.50 0.90 0.76 19-FEB-13:30 160.41 0.00 0.00 0.17 126.90 0.00 0.00 0.00
March 296.17 0.86 0.76 01-MAR-12:09 212.59 0.00 0.00 3.83 158.55 0.00 0.00 0.00
April 296.67 0.82 0.76 03-APR-10:50 283.80 0.00 0.00 49.17 200.38 0.00 0.00 0.00
May 415.33 0.79 0.76 01-MAY-06:19 400.36 0.00 0.00 221.17 234.79 0.00 0.00 4.33
June 421.50 0.79 0.76 01-JUN-05:10 368.45 0.00 0.00 197.67 274.97 0.00 0.00 29.67
July 430.33 0.80 0.76 01-JUL-18:10 346.56 0.00 0.00 202.00 244.67 0.00 0.00 11.50
August 394.50 0.82 0.76 01-AUG-05:00 304.31 0.00 0.00 74.33 200.88 0.00 0.00 0.00
September 354.00 0.85 0.76 01-SEP-12:09 237.26 0.00 0.00 23.67 172.23 0.00 0.00 0.00
October 262.67 0.87 0.76 01-OCT-12:20 198.04 0.00 0.00 0.00 153.83 0.00 0.00 0.00
November 257.67 0.90 0.76 01-NOV-11:30 151.16 0.00 0.00 0.00 120.64 0.00 0.00 0.00
December 251.17 0.91 0.83 31-DEC-12:30 139.32 0.00 0.00 0.00 110.39 0.00 0.00 0.00
                         
Annual Sum or Average 3902.00 0.84     262.47 0.00 0.00 772.00 185.75 0.00 0.00 45.50
Minimum of Months 245.50 0.79 0.76   133.47 0.00 0.00 0.00 105.31 0.00 0.00 0.00
Maximum of Months 430.33 0.92 0.83   400.36 0.00 0.00 221.17 274.97 0.00 0.00 29.67



Table of Contents

Report: DaylightingReportMonthly

For: PERIMETER_ZN_4_DAYLCTRL

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 276.50 0.84 0.76 01-JAN-13:09 1829.69 22.91 99.83 111.67 526.01 20.24 77.83 86.33
February 245.50 0.83 0.76 01-FEB-11:09 1401.41 20.71 58.67 100.83 876.09 20.33 60.00 86.17
March 296.17 0.82 0.76 01-MAR-11:09 452.92 17.36 34.17 128.00 957.06 19.58 67.50 105.17
April 296.67 0.81 0.76 03-APR-10:30 448.81 17.24 25.33 142.00 366.17 16.77 6.83 99.33
May 415.33 0.81 0.76 01-MAY-08:30 459.14 17.25 15.17 212.83 376.03 16.66 1.67 152.83
June 421.50 0.81 0.76 01-JUN-10:50 449.36 16.39 0.17 193.50 414.56 16.14 0.00 162.17
July 430.33 0.81 0.76 01-JUL-13:20 438.34 16.76 7.50 205.50 376.15 16.28 1.67 160.83
August 394.50 0.82 0.76 01-AUG-10:39 422.37 16.55 8.00 169.17 361.20 16.22 1.00 120.00
September 354.00 0.82 0.76 01-SEP-11:39 519.47 17.52 48.50 159.33 389.96 17.12 31.00 127.00
October 262.67 0.81 0.76 01-OCT-11:20 1658.70 20.94 57.00 117.83 800.73 20.66 63.17 93.67
November 257.67 0.83 0.76 01-NOV-09:30 1860.35 23.56 95.33 104.50 1016.29 22.76 92.00 87.50
December 251.17 0.83 0.76 01-DEC-12:20 1502.53 24.01 96.17 98.83 385.96 20.62 66.00 72.50
                         
Annual Sum or Average 3902.00 0.82     853.13 18.78 545.83 1744.00 536.92 18.20 468.67 1353.50
Minimum of Months 245.50 0.81 0.76   422.37 16.39 0.17 98.83 361.20 16.14 0.00 72.50
Maximum of Months 430.33 0.84 0.76   1860.35 24.01 99.83 212.83 1016.29 22.76 92.00 162.17



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:1 HEATING COIL

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.353215E+09 6051.13 09-JAN-08:62 0.00 0.00 0.00 0.00 0.00
February 0.449327E+09 5635.13 17-FEB-08:62 0.00 0.00 0.00 0.00 0.00
March 0.165264E+09 6247.38 07-MAR-08:61 0.00 0.00 0.00 0.00 0.00
April 0.118790E+09 7062.51 18-APR-07:02 0.00 0.00 0.00 0.00 0.00
May 1895248.28 4780.27 01-MAY-07:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:05 0.00 0.00 0.00 0.00 0.00
October 85515230.71 3619.11 25-OCT-07:03 0.00 0.00 0.00 0.00 0.00
November 0.144867E+09 4355.31 03-NOV-07:03 0.00 0.00 0.00 0.00 0.00
December 0.202855E+09 6313.43 26-DEC-06:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.152173E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.449327E+09 7062.51   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:2 HEATING COIL

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.790944E+09 6564.24 09-JAN-08:62 0.00 0.00 0.00 0.00 0.00
February 0.130846E+10 5428.37 07-FEB-17:20 0.00 0.00 0.00 0.00 0.00
March 0.118697E+10 7397.76 09-MAR-08:61 0.00 0.00 0.00 0.00 0.00
April 0.911767E+09 8125.21 19-APR-07:01 0.00 0.00 0.00 0.00 0.00
May 0.189121E+09 8564.47 04-MAY-07:01 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 8642317.36 4418.28 22-SEP-07:03 0.00 0.00 0.00 0.00 0.00
October 0.502486E+09 5807.90 26-OCT-06:02 0.00 0.00 0.00 0.00 0.00
November 0.618889E+09 5976.68 22-NOV-08:62 0.00 0.00 0.00 0.00 0.00
December 0.600848E+09 7435.12 01-DEC-07:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.611813E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.130846E+10 8564.47   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:3 HEATING COIL

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.909019E+09 5060.22 20-JAN-07:02 0.00 0.00 0.00 0.00 0.00
February 0.108437E+10 4736.72 27-FEB-07:01 0.00 0.00 0.00 0.00 0.00
March 0.684954E+09 5609.13 08-MAR-07:02 0.00 0.00 0.00 0.00 0.00
April 0.424373E+09 5280.88 18-APR-06:01 0.00 0.00 0.00 0.00 0.00
May 33301273.97 5225.32 01-MAY-06:01 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 71605.90 477.37 22-SEP-07:03 0.00 0.00 0.00 0.00 0.00
October 0.283065E+09 4525.64 26-OCT-06:02 0.00 0.00 0.00 0.00 0.00
November 0.493361E+09 4028.41 22-NOV-08:62 0.00 0.00 0.00 0.00 0.00
December 0.592943E+09 5793.60 01-DEC-07:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.450546E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.108437E+10 5793.60   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:4 HEATING COIL

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.215833E+10 6210.85 20-JAN-08:62 0.00 0.00 0.00 0.00 0.00
February 0.232335E+10 5860.29 27-FEB-08:62 0.00 0.00 0.00 0.00 0.00
March 0.162047E+10 6772.07 08-MAR-08:62 0.00 0.00 0.00 0.00 0.00
April 0.934893E+09 7253.85 19-APR-07:01 0.00 0.00 0.00 0.00 0.00
May 0.116699E+09 7646.00 04-MAY-07:01 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 414061.43 2760.41 22-SEP-07:03 0.00 0.00 0.00 0.00 0.00
October 0.464919E+09 5305.47 26-OCT-07:03 0.00 0.00 0.00 0.00 0.00
November 0.111866E+10 6699.79 06-NOV-08:62 0.00 0.00 0.00 0.00 0.00
December 0.149409E+10 6637.77 01-DEC-07:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.102318E+11     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.232335E+10 7646.00   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:5 HEATING COIL

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.886531E+09 6408.56 23-JAN-07:01 0.00 0.00 0.00 0.00 0.00
February 0.109548E+10 6097.29 27-FEB-07:01 0.00 0.00 0.00 0.00 0.00
March 0.746809E+09 6449.51 07-MAR-08:61 0.00 0.00 0.00 0.00 0.00
April 0.471897E+09 6797.77 18-APR-06:01 0.00 0.00 0.00 0.00 0.00
May 49442847.81 6726.25 01-MAY-06:01 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 85166.66 567.78 22-SEP-07:03 0.00 0.00 0.00 0.00 0.00
October 0.269997E+09 4170.55 25-OCT-07:03 0.00 0.00 0.00 0.00 0.00
November 0.465831E+09 4383.72 22-NOV-07:01 0.00 0.00 0.00 0.00 0.00
December 0.586730E+09 7457.75 01-DEC-07:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.457280E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.109548E+10 7457.75   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:1_SUPPHEATCOIL

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.115234E+09 4151.69 02-JAN-07:01 0.00 0.00 0.00 0.00 0.00
February 33018655.73 4151.69 01-FEB-07:01 0.00 0.00 0.00 0.00 0.00
March 9679998.97 4151.69 02-MAR-08:62 0.00 0.00 0.00 0.00 0.00
April 7195217.35 4151.69 03-APR-06:01 0.00 0.00 0.00 0.00 0.00
May 218707.11 1458.05 02-MAY-07:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:05 0.00 0.00 0.00 0.00 0.00
October 2732390.46 4151.69 30-OCT-06:01 0.00 0.00 0.00 0.00 0.00
November 19573463.25 4151.69 01-NOV-06:01 0.00 0.00 0.00 0.00 0.00
December 0.345257E+09 4151.69 08-DEC-07:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.532909E+09     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.345257E+09 4151.69   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:2_SUPPHEATCOIL

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.407250E+09 7107.91 03-JAN-06:01 0.00 0.00 0.00 0.00 0.00
February 0.392510E+09 7107.91 02-FEB-06:01 0.00 0.00 0.00 0.00 0.00
March 0.168482E+09 7107.91 02-MAR-07:01 0.00 0.00 0.00 0.00 0.00
April 0.143318E+09 7107.91 03-APR-05:01 0.00 0.00 0.00 0.00 0.00
May 5943569.33 5617.00 02-MAY-06:01 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 26587.05 177.25 22-SEP-07:03 0.00 0.00 0.00 0.00 0.00
October 0.152495E+09 7107.91 30-OCT-05:01 0.00 0.00 0.00 0.00 0.00
November 0.190769E+09 7107.91 02-NOV-05:01 0.00 0.00 0.00 0.00 0.00
December 0.125870E+10 7107.91 19-DEC-07:02 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.271950E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.125870E+10 7107.91   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:3_SUPPHEATCOIL

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.224278E+09 4454.79 02-JAN-06:01 0.00 0.00 0.00 0.00 0.00
February 0.168264E+09 4454.79 01-FEB-06:01 0.00 0.00 0.00 0.00 0.00
March 44336549.53 4454.79 01-MAR-07:01 0.00 0.00 0.00 0.00 0.00
April 26835325.62 4454.79 03-APR-05:01 0.00 0.00 0.00 0.00 0.00
May 713825.04 4216.71 02-MAY-06:01 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:05 0.00 0.00 0.00 0.00 0.00
October 18158510.98 4454.79 23-OCT-06:01 0.00 0.00 0.00 0.00 0.00
November 50045900.64 4454.79 01-NOV-05:01 0.00 0.00 0.00 0.00 0.00
December 0.857337E+09 4454.79 06-DEC-07:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.138997E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.857337E+09 4454.79   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:4_SUPPHEATCOIL

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.550132E+09 7005.39 03-JAN-06:01 0.00 0.00 0.00 0.00 0.00
February 0.522765E+09 7005.39 02-FEB-06:01 0.00 0.00 0.00 0.00 0.00
March 0.144183E+09 7005.39 02-MAR-06:02 0.00 0.00 0.00 0.00 0.00
April 0.102090E+09 7005.39 03-APR-05:01 0.00 0.00 0.00 0.00 0.00
May 1971278.15 5106.05 02-MAY-06:01 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:05 0.00 0.00 0.00 0.00 0.00
October 95138750.65 7005.39 30-OCT-05:01 0.00 0.00 0.00 0.00 0.00
November 0.157068E+09 7005.39 02-NOV-05:01 0.00 0.00 0.00 0.00 0.00
December 0.157881E+10 7005.39 19-DEC-06:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.315215E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.157881E+10 7005.39   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:5_SUPPHEATCOIL

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.180277E+09 4454.79 02-JAN-06:01 0.00 0.00 0.00 0.00 0.00
February 98147138.88 4454.79 01-FEB-06:01 0.00 0.00 0.00 0.00 0.00
March 34431791.38 4454.79 01-MAR-07:01 0.00 0.00 0.00 0.00 0.00
April 12027880.69 4454.79 03-APR-05:01 0.00 0.00 0.00 0.00 0.00
May 700115.33 4454.79 02-MAY-06:01 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:05 0.00 0.00 0.00 0.00 0.00
October 6070015.27 4454.79 23-OCT-06:01 0.00 0.00 0.00 0.00 0.00
November 30189745.26 4454.79 01-NOV-05:01 0.00 0.00 0.00 0.00 0.00
December 0.797131E+09 4454.79 06-DEC-07:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.115897E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.797131E+09 4454.79   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:1 HP COOLING COIL

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 53186946.73 52368052.84 958.64 25-JAN-15:57 958.64 0.00
February 0.00 0.00 2557088.37 2542428.26 279.20 27-FEB-16:24 279.20 0.00
March 0.00 0.00 0.315510E+09 0.309236E+09 2400.41 15-MAR-14:30 2400.41 0.00
April 0.00 0.00 0.236118E+09 0.224026E+09 1681.68 20-APR-13:25 1643.13 0.00
May 0.00 0.00 0.128153E+10 0.117245E+10 6329.10 18-MAY-07:02 6252.75 0.00
June 0.00 0.00 0.356214E+10 0.332419E+10 6779.70 21-JUN-07:02 4984.44 0.00
July 0.00 0.00 0.357754E+10 0.325627E+10 6830.87 28-JUL-07:02 4800.70 0.00
August 0.00 0.00 0.384950E+10 0.355831E+10 6827.69 04-AUG-07:02 4929.17 0.00
September 0.00 0.00 0.281415E+10 0.269744E+10 6553.91 06-SEP-07:02 5630.05 0.00
October 0.00 0.00 0.100024E+10 0.965582E+09 6185.38 10-OCT-07:03 6185.38 0.00
November 0.00 0.00 0.256523E+09 0.247567E+09 2198.92 09-NOV-13:57 2108.63 0.00
December 0.00 0.00 10992593.19 10992072.13 777.00 04-DEC-15:37 777.00 0.00
                 
Annual Sum or Average 0.00 0.00 0.169600E+11 0.158210E+11       0.00
Minimum of Months 0.00 0.00 2557088.37 2542428.26 279.20   279.20 0.00
Maximum of Months 0.00 0.00 0.384950E+10 0.355831E+10 6830.87   6252.75 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:2 HP COOLING COIL

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.397581E+09 0.397397E+09 4079.31 20-JAN-14:15 4079.31 0.00
February 0.00 0.00 0.182376E+09 0.182376E+09 2838.88 27-FEB-14:15 2838.88 0.00
March 0.00 0.00 0.525090E+09 0.525090E+09 4550.19 14-MAR-13:30 4550.19 0.00
April 0.00 0.00 0.171631E+09 0.170787E+09 1983.15 20-APR-13:00 1983.15 0.00
May 0.00 0.00 0.547758E+09 0.540330E+09 2937.95 17-MAY-13:50 2937.95 0.00
June 0.00 0.00 0.270221E+10 0.260392E+10 6994.16 19-JUN-07:02 6707.43 0.00
July 0.00 0.00 0.274577E+10 0.259476E+10 7310.99 24-JUL-06:01 5985.31 0.00
August 0.00 0.00 0.346254E+10 0.332994E+10 7459.78 04-AUG-07:02 5061.52 0.00
September 0.00 0.00 0.310083E+10 0.307016E+10 7040.43 06-SEP-07:02 6226.70 0.00
October 0.00 0.00 0.144551E+10 0.144349E+10 6631.59 10-OCT-11:45 6631.59 0.00
November 0.00 0.00 0.797773E+09 0.797750E+09 5746.67 07-NOV-13:55 5746.67 0.00
December 0.00 0.00 0.295421E+09 0.295421E+09 3336.45 04-DEC-14:25 3336.45 0.00
                 
Annual Sum or Average 0.00 0.00 0.163745E+11 0.159514E+11       0.00
Minimum of Months 0.00 0.00 0.171631E+09 0.170787E+09 1983.15   1983.15 0.00
Maximum of Months 0.00 0.00 0.346254E+10 0.332994E+10 7459.78   6707.43 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:3 HP COOLING COIL

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 2506074.25 2506074.25 571.33 20-JAN-14:00 571.33 0.00
February 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 0.00 0.00
March 0.00 0.00 0.144391E+09 0.144391E+09 1472.19 14-MAR-10:12 1472.19 0.00
April 0.00 0.00 0.148209E+09 0.147908E+09 1301.27 21-APR-10:05 1301.27 0.00
May 0.00 0.00 0.606990E+09 0.596680E+09 5293.33 17-MAY-07:01 5293.33 0.00
June 0.00 0.00 0.230159E+10 0.223961E+10 5699.32 21-JUN-07:02 4472.40 0.00
July 0.00 0.00 0.213820E+10 0.205358E+10 5771.33 28-JUL-07:02 4141.65 0.00
August 0.00 0.00 0.243791E+10 0.235773E+10 5740.81 04-AUG-07:02 4385.64 0.00
September 0.00 0.00 0.171263E+10 0.169729E+10 5479.17 06-SEP-07:02 5134.17 0.00
October 0.00 0.00 0.424940E+09 0.424224E+09 2622.83 11-OCT-07:02 2622.83 0.00
November 0.00 0.00 0.107362E+09 0.107362E+09 1114.02 09-NOV-13:13 1114.02 0.00
December 0.00 0.00 0.00 0.00 0.00 01-DEC-00:05 0.00 0.00
                 
Annual Sum or Average 0.00 0.00 0.100247E+11 0.977128E+10       0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00   0.00 0.00
Maximum of Months 0.00 0.00 0.243791E+10 0.235773E+10 5771.33   5293.33 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:4 HP COOLING COIL

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.00 0.00 0.00 01-JAN-00:05 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 0.00 0.00
March 0.00 0.00 31825065.13 31825065.13 921.25 15-MAR-15:27 921.25 0.00
April 0.00 0.00 14774713.13 14774713.13 661.01 20-APR-14:00 661.01 0.00
May 0.00 0.00 0.462804E+09 0.449746E+09 2478.87 17-MAY-14:00 2478.87 0.00
June 0.00 0.00 0.255850E+10 0.245861E+10 6564.06 21-JUN-07:02 4848.21 0.00
July 0.00 0.00 0.252095E+10 0.237764E+10 6597.84 28-JUL-07:02 4612.79 0.00
August 0.00 0.00 0.264204E+10 0.251817E+10 6641.35 04-AUG-07:02 4746.44 0.00
September 0.00 0.00 0.179740E+10 0.176875E+10 6271.11 06-SEP-07:02 5702.49 0.00
October 0.00 0.00 0.256834E+09 0.256206E+09 2505.84 11-OCT-14:47 2505.84 0.00
November 0.00 0.00 33728597.98 33728597.98 1079.77 09-NOV-13:57 1079.77 0.00
December 0.00 0.00 0.00 0.00 0.00 01-DEC-00:05 0.00 0.00
                 
Annual Sum or Average 0.00 0.00 0.103189E+11 0.990944E+10       0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00   0.00 0.00
Maximum of Months 0.00 0.00 0.264204E+10 0.251817E+10 6641.35   5702.49 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:5 HP COOLING COIL

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 31536351.69 31536351.69 1166.27 20-JAN-15:58 1166.27 0.00
February 0.00 0.00 7122130.29 7122130.29 816.67 17-FEB-16:38 816.67 0.00
March 0.00 0.00 0.161701E+09 0.161701E+09 2222.83 15-MAR-15:55 2222.83 0.00
April 0.00 0.00 0.110449E+09 0.109650E+09 1862.76 07-APR-16:00 1862.76 0.00
May 0.00 0.00 0.563312E+09 0.547104E+09 2816.72 31-MAY-15:53 2708.15 0.00
June 0.00 0.00 0.211329E+10 0.204404E+10 7394.07 21-JUN-07:02 5626.65 0.00
July 0.00 0.00 0.195345E+10 0.185727E+10 7453.96 31-JUL-07:02 5335.99 0.00
August 0.00 0.00 0.220129E+10 0.211575E+10 7433.42 04-AUG-07:02 5546.90 0.00
September 0.00 0.00 0.163688E+10 0.161647E+10 7061.38 06-SEP-07:02 6644.03 0.00
October 0.00 0.00 0.500328E+09 0.498922E+09 3539.03 11-OCT-15:54 3539.03 0.00
November 0.00 0.00 0.147120E+09 0.147114E+09 2118.92 07-NOV-15:58 2118.92 0.00
December 0.00 0.00 18148145.72 18148145.72 873.29 04-DEC-15:40 873.29 0.00
                 
Annual Sum or Average 0.00 0.00 0.944463E+10 0.915482E+10       0.00
Minimum of Months 0.00 0.00 7122130.29 7122130.29 816.67   816.67 0.00
Maximum of Months 0.00 0.00 0.220129E+10 0.211575E+10 7453.96   6644.03 0.00



Table of Contents

Report: PlantLoopDemandReportMonthly

For: SWHSYS1

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

PLANT SUPPLY SIDE COOLING DEMAND RATE [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} PLANT SUPPLY SIDE HEATING DEMAND RATE [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP}
January 0.00 0.00 01-JAN-00:05 289.93 694.43 31-JAN-12:13
February 0.00 0.00 01-FEB-00:10 155.38 696.80 13-FEB-12:17
March 0.00 0.00 01-MAR-00:10 0.00 0.00 01-MAR-00:10
April 0.00 0.00 01-APR-00:10 0.00 0.00 01-APR-00:10
May 0.00 0.00 01-MAY-00:10 0.00 0.00 01-MAY-00:10
June 0.00 0.00 01-JUN-00:10 0.00 0.00 01-JUN-00:10
July 0.00 0.00 01-JUL-00:10 0.00 0.00 01-JUL-00:10
August 0.00 0.00 01-AUG-00:10 0.00 0.00 01-AUG-00:10
September 0.00 0.00 01-SEP-00:05 0.00 0.00 01-SEP-00:05
October 0.00 0.00 01-OCT-00:10 0.00 0.00 01-OCT-00:10
November 0.00 0.00 01-NOV-00:10 0.00 0.00 01-NOV-00:10
December 0.00 0.00 01-DEC-00:05 0.00 0.00 01-DEC-00:05
             
Annual Sum or Average 0.00     36.54    
Minimum of Months 0.00 0.00   0.00 0.00  
Maximum of Months 0.00 0.00   289.93 696.80  



Table of Contents

Report: FanReportMonthly

For: PSZ-AC:1 FAN

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.435815E+09 0.41 443.44 02-JAN-06:01 1.13
February 0.394308E+09 0.41 443.44 01-FEB-06:01 1.13
March 0.477321E+09 0.45 443.44 01-MAR-06:03 1.12
April 0.415061E+09 0.41 443.44 03-APR-05:01 1.13
May 0.456568E+09 0.43 443.44 01-MAY-05:03 1.12
June 0.456568E+09 0.45 443.44 01-JUN-05:10 1.12
July 0.415061E+09 0.39 443.44 03-JUL-05:10 1.12
August 0.477321E+09 0.45 443.44 01-AUG-05:05 1.11
September 0.415061E+09 0.41 443.44 01-SEP-05:10 1.12
October 0.435815E+09 0.41 443.44 02-OCT-05:05 1.12
November 0.435815E+09 0.43 443.44 01-NOV-05:01 1.13
December 0.415061E+09 0.39 443.44 01-DEC-06:05 1.13
           
Annual Sum or Average 0.522977E+10 0.42      
Minimum of Months 0.394308E+09 0.39 443.44   1.11
Maximum of Months 0.477321E+09 0.45 443.44   1.13



Table of Contents

Report: FanReportMonthly

For: PSZ-AC:2 FAN

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.478097E+09 0.42 481.04 02-JAN-06:01 1.13
February 0.471296E+09 0.49 481.04 01-FEB-06:01 1.13
March 0.542891E+09 0.50 481.04 01-MAR-06:03 1.13
April 0.463147E+09 0.44 481.04 03-APR-03:05 1.13
May 0.495282E+09 0.43 481.04 01-MAY-05:03 1.13
June 0.495282E+09 0.45 481.04 01-JUN-05:10 1.12
July 0.450257E+09 0.39 481.04 03-JUL-05:10 1.13
August 0.517795E+09 0.45 481.04 01-AUG-05:05 1.12
September 0.454457E+09 0.43 481.04 01-SEP-05:10 1.13
October 0.475147E+09 0.43 481.04 02-OCT-05:05 1.13
November 0.472770E+09 0.43 481.04 01-NOV-05:01 1.13
December 0.504528E+09 0.45 481.04 01-DEC-06:05 1.14
           
Annual Sum or Average 0.582095E+10 0.44      
Minimum of Months 0.450257E+09 0.39 481.04   1.12
Maximum of Months 0.542891E+09 0.50 481.04   1.14



Table of Contents

Report: FanReportMonthly

For: PSZ-AC:3 FAN

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.410078E+09 0.53 374.84 01-JAN-05:23 1.13
February 0.387229E+09 0.54 374.84 01-FEB-06:01 1.13
March 0.427936E+09 0.52 374.84 01-MAR-06:03 1.13
April 0.364401E+09 0.47 374.84 02-APR-22:53 1.13
May 0.385935E+09 0.43 374.84 01-MAY-05:03 1.13
June 0.385935E+09 0.45 374.84 01-JUN-05:10 1.12
July 0.352781E+09 0.41 374.84 03-JUL-05:10 1.13
August 0.403836E+09 0.46 374.84 01-AUG-05:05 1.12
September 0.350850E+09 0.41 374.84 01-SEP-05:10 1.13
October 0.368514E+09 0.42 374.84 02-OCT-05:05 1.13
November 0.372765E+09 0.43 374.84 01-NOV-05:01 1.13
December 0.427926E+09 0.54 374.84 01-DEC-06:05 1.13
           
Annual Sum or Average 0.463819E+10 0.47      
Minimum of Months 0.350850E+09 0.41 374.84   1.12
Maximum of Months 0.427936E+09 0.54 374.84   1.13



Table of Contents

Report: FanReportMonthly

For: PSZ-AC:4 FAN

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.504746E+09 0.57 429.46 01-JAN-01:33 1.13
February 0.463600E+09 0.55 429.46 01-FEB-06:01 1.13
March 0.503189E+09 0.53 429.46 01-MAR-06:03 1.13
April 0.424280E+09 0.47 429.46 02-APR-22:53 1.13
May 0.442168E+09 0.43 429.46 01-MAY-05:03 1.13
June 0.442168E+09 0.45 429.46 01-JUN-05:10 1.12
July 0.401971E+09 0.39 429.46 03-JUL-05:10 1.13
August 0.462266E+09 0.45 429.46 01-AUG-05:05 1.12
September 0.401971E+09 0.41 429.46 01-SEP-05:10 1.13
October 0.422790E+09 0.42 429.46 02-OCT-05:05 1.13
November 0.425382E+09 0.43 429.46 01-NOV-05:01 1.13
December 0.516626E+09 0.55 429.46 01-DEC-06:05 1.13
           
Annual Sum or Average 0.541116E+10 0.47      
Minimum of Months 0.401971E+09 0.39 429.46   1.12
Maximum of Months 0.516626E+09 0.57 429.46   1.13



Table of Contents

Report: FanReportMonthly

For: PSZ-AC:5 FAN

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.516607E+09 0.53 482.51 02-JAN-06:01 1.13
February 0.481946E+09 0.53 482.51 01-FEB-06:01 1.13
March 0.544357E+09 0.52 482.51 01-MAR-06:03 1.13
April 0.465650E+09 0.47 482.51 03-APR-03:33 1.13
May 0.496790E+09 0.43 482.51 01-MAY-05:03 1.13
June 0.499044E+09 0.46 482.51 01-JUN-05:10 1.12
July 0.454800E+09 0.41 482.51 03-JUL-05:10 1.13
August 0.521231E+09 0.47 482.51 01-AUG-05:05 1.12
September 0.453318E+09 0.42 482.51 01-SEP-05:10 1.13
October 0.474446E+09 0.42 482.51 02-OCT-05:05 1.13
November 0.478394E+09 0.43 482.51 01-NOV-05:01 1.13
December 0.543019E+09 0.54 482.51 01-DEC-06:05 1.13
           
Annual Sum or Average 0.592960E+10 0.47      
Minimum of Months 0.453318E+09 0.41 482.51   1.12
Maximum of Months 0.544357E+09 0.54 482.51   1.13



Table of Contents

Report: PumpReportMonthly

For: SWHSYS1 PUMP

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

PUMP ELECTRICITY ENERGY [J] PUMP FLUID HEAT GAIN ENERGY [J] PUMP ELECTRICITY RATE {Maximum} [W] PUMP ELECTRICITY RATE {TIMESTAMP} PUMP SHAFT POWER {AT MAX/MIN} [W] PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s]
January 0.02 0.01 0.00 02-JAN-07:01 0.00 0.00 42.95 0.00
February 0.01 0.00 0.00 01-FEB-07:01 0.00 0.00 7.98 0.00
March 0.00 0.00 0.00 01-MAR-00:10 0.00 0.00 7.84 0.00
April 0.00 0.00 0.00 01-APR-00:10 0.00 0.00 7.84 0.00
May 0.00 0.00 0.00 01-MAY-00:10 0.00 0.00 7.84 0.00
June 0.00 0.00 0.00 01-JUN-00:10 0.00 0.00 7.84 0.00
July 0.00 0.00 0.00 01-JUL-00:10 0.00 0.00 7.84 0.00
August 0.00 0.00 0.00 01-AUG-00:10 0.00 0.00 7.84 0.00
September 0.00 0.00 0.00 01-SEP-00:05 0.00 0.00 7.84 0.00
October 0.00 0.00 0.00 01-OCT-00:10 0.00 0.00 7.84 0.00
November 0.00 0.00 0.00 01-NOV-00:10 0.00 0.00 7.84 0.00
December 0.00 0.00 0.00 01-DEC-00:05 0.00 0.00 7.84 0.00
                 
Annual Sum or Average 0.03 0.01            
Minimum of Months 0.00 0.00 0.00   0.00 0.00 7.84 0.00
Maximum of Months 0.02 0.01 0.00   0.00 0.00 42.95 0.00



Table of Contents

Report: CondLoopDemandReportMonthly

For: SWHSYS1

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

PLANT SUPPLY SIDE COOLING DEMAND RATE [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] PLANT SUPPLY SIDE HEATING DEMAND RATE [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP}
January 0.00 0.00 01-JAN-00:05 48.89 48.89 289.93 694.43 31-JAN-12:13
February 0.00 0.00 01-FEB-00:10 7.98 7.98 155.38 696.80 13-FEB-12:17
March 0.00 0.00 01-MAR-00:10 7.84 7.84 0.00 0.00 01-MAR-00:10
April 0.00 0.00 01-APR-00:10 7.84 7.84 0.00 0.00 01-APR-00:10
May 0.00 0.00 01-MAY-00:10 7.84 7.84 0.00 0.00 01-MAY-00:10
June 0.00 0.00 01-JUN-00:10 7.84 7.84 0.00 0.00 01-JUN-00:10
July 0.00 0.00 01-JUL-00:10 7.84 7.84 0.00 0.00 01-JUL-00:10
August 0.00 0.00 01-AUG-00:10 7.84 7.84 0.00 0.00 01-AUG-00:10
September 0.00 0.00 01-SEP-00:05 7.84 7.84 0.00 0.00 01-SEP-00:05
October 0.00 0.00 01-OCT-00:10 7.84 7.84 0.00 0.00 01-OCT-00:10
November 0.00 0.00 01-NOV-00:10 7.84 7.84 0.00 0.00 01-NOV-00:10
December 0.00 0.00 01-DEC-00:05 7.84 7.84 0.00 0.00 01-DEC-00:05
                 
Annual Sum or Average 0.00         36.54    
Minimum of Months 0.00 0.00   7.84 7.84 0.00 0.00  
Maximum of Months 0.00 0.00   48.89 48.89 289.93 696.80  



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: ATTIC

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00 0.00
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: PSZ-AC:1

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.672527E+09 0.00 0.00
February 0.00 0.00 0.00 0.649889E+09 0.00 0.00
March 0.00 0.00 0.00 0.649674E+09 0.00 0.00
April 0.00 0.00 0.00 0.539838E+09 0.00 0.00
May 0.00 0.00 0.00 0.745295E+09 0.00 0.00
June 0.00 0.00 0.00 0.128422E+10 0.00 0.00
July 0.00 0.00 0.00 0.122502E+10 0.00 0.00
August 0.00 0.00 0.00 0.135159E+10 0.00 0.00
September 0.00 0.00 0.00 0.103896E+10 0.00 0.00
October 0.00 0.00 0.00 0.726829E+09 0.00 0.00
November 0.00 0.00 0.00 0.608241E+09 0.00 0.00
December 0.00 0.00 0.00 0.522660E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.100147E+11 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.522660E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.135159E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: PSZ-AC:2

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.102219E+10 0.00 0.00
February 0.00 0.00 0.00 0.120999E+10 0.00 0.00
March 0.00 0.00 0.00 0.124764E+10 0.00 0.00
April 0.00 0.00 0.00 0.912615E+09 0.00 0.00
May 0.00 0.00 0.00 0.691914E+09 0.00 0.00
June 0.00 0.00 0.00 0.115530E+10 0.00 0.00
July 0.00 0.00 0.00 0.110114E+10 0.00 0.00
August 0.00 0.00 0.00 0.132839E+10 0.00 0.00
September 0.00 0.00 0.00 0.114896E+10 0.00 0.00
October 0.00 0.00 0.00 0.108654E+10 0.00 0.00
November 0.00 0.00 0.00 0.102638E+10 0.00 0.00
December 0.00 0.00 0.00 0.854474E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.127855E+11 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.691914E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.132839E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: PSZ-AC:3

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.943606E+09 0.00 0.00
February 0.00 0.00 0.00 0.985323E+09 0.00 0.00
March 0.00 0.00 0.00 0.834012E+09 0.00 0.00
April 0.00 0.00 0.00 0.621264E+09 0.00 0.00
May 0.00 0.00 0.00 0.539842E+09 0.00 0.00
June 0.00 0.00 0.00 0.937408E+09 0.00 0.00
July 0.00 0.00 0.00 0.859054E+09 0.00 0.00
August 0.00 0.00 0.00 0.975712E+09 0.00 0.00
September 0.00 0.00 0.00 0.742851E+09 0.00 0.00
October 0.00 0.00 0.00 0.653107E+09 0.00 0.00
November 0.00 0.00 0.00 0.709582E+09 0.00 0.00
December 0.00 0.00 0.00 0.733050E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.953481E+10 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.539842E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.985323E+09 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: PSZ-AC:4

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.161710E+10 0.00 0.00
February 0.00 0.00 0.00 0.159072E+10 0.00 0.00
March 0.00 0.00 0.00 0.128551E+10 0.00 0.00
April 0.00 0.00 0.00 0.859147E+09 0.00 0.00
May 0.00 0.00 0.00 0.594121E+09 0.00 0.00
June 0.00 0.00 0.00 0.106100E+10 0.00 0.00
July 0.00 0.00 0.00 0.996492E+09 0.00 0.00
August 0.00 0.00 0.00 0.108871E+10 0.00 0.00
September 0.00 0.00 0.00 0.816954E+09 0.00 0.00
October 0.00 0.00 0.00 0.767090E+09 0.00 0.00
November 0.00 0.00 0.00 0.104595E+10 0.00 0.00
December 0.00 0.00 0.00 0.118770E+10 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.129105E+11 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.594121E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.161710E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: PSZ-AC:5

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.105551E+10 0.00 0.00
February 0.00 0.00 0.00 0.109173E+10 0.00 0.00
March 0.00 0.00 0.00 0.988818E+09 0.00 0.00
April 0.00 0.00 0.00 0.740907E+09 0.00 0.00
May 0.00 0.00 0.00 0.647755E+09 0.00 0.00
June 0.00 0.00 0.00 0.102509E+10 0.00 0.00
July 0.00 0.00 0.00 0.930997E+09 0.00 0.00
August 0.00 0.00 0.00 0.105785E+10 0.00 0.00
September 0.00 0.00 0.00 0.837727E+09 0.00 0.00
October 0.00 0.00 0.00 0.773345E+09 0.00 0.00
November 0.00 0.00 0.00 0.812433E+09 0.00 0.00
December 0.00 0.00 0.00 0.850876E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.108130E+11 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.647755E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.109173E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: PSZ-AC:1

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.435815E+09 53186946.73 0.468450E+09 0.00 0.00 0.00 0.00 0.00
February 0.394308E+09 2557088.37 0.482345E+09 0.00 0.00 0.00 0.00 0.00
March 0.477321E+09 0.315510E+09 0.174944E+09 0.00 0.00 0.00 0.00 0.00
April 0.415061E+09 0.236118E+09 0.125985E+09 0.00 0.00 0.00 0.00 0.00
May 0.456568E+09 0.128153E+10 2113955.39 0.00 0.00 0.00 0.00 0.00
June 0.456568E+09 0.356214E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.415061E+09 0.357754E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.477321E+09 0.384950E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.415061E+09 0.281415E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.435815E+09 0.100024E+10 88247621.17 0.00 0.00 0.00 0.00 0.00
November 0.435815E+09 0.256523E+09 0.164441E+09 0.00 0.00 0.00 0.00 0.00
December 0.415061E+09 10992593.19 0.548112E+09 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.522977E+10 0.169600E+11 0.205464E+10 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.394308E+09 2557088.37 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.477321E+09 0.384950E+10 0.548112E+09 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: PSZ-AC:2

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.478097E+09 0.397581E+09 0.119819E+10 0.00 0.00 0.00 0.00 0.00
February 0.471296E+09 0.182376E+09 0.170098E+10 0.00 0.00 0.00 0.00 0.00
March 0.542891E+09 0.525090E+09 0.135545E+10 0.00 0.00 0.00 0.00 0.00
April 0.463147E+09 0.171631E+09 0.105508E+10 0.00 0.00 0.00 0.00 0.00
May 0.495282E+09 0.547758E+09 0.195064E+09 0.00 0.00 0.00 0.00 0.00
June 0.495282E+09 0.270221E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.450257E+09 0.274577E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.517795E+09 0.346254E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.454457E+09 0.310083E+10 8668904.42 0.00 0.00 0.00 0.00 0.00
October 0.475147E+09 0.144551E+10 0.654980E+09 0.00 0.00 0.00 0.00 0.00
November 0.472770E+09 0.797773E+09 0.809658E+09 0.00 0.00 0.00 0.00 0.00
December 0.504528E+09 0.295421E+09 0.185955E+10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.582095E+10 0.163745E+11 0.883762E+10 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.450257E+09 0.171631E+09 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.542891E+09 0.346254E+10 0.185955E+10 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: PSZ-AC:3

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.410078E+09 2506074.25 0.113330E+10 0.00 0.00 0.00 0.00 0.00
February 0.387229E+09 0.00 0.125264E+10 0.00 0.00 0.00 0.00 0.00
March 0.427936E+09 0.144391E+09 0.729291E+09 0.00 0.00 0.00 0.00 0.00
April 0.364401E+09 0.148209E+09 0.451208E+09 0.00 0.00 0.00 0.00 0.00
May 0.385935E+09 0.606990E+09 34015099.01 0.00 0.00 0.00 0.00 0.00
June 0.385935E+09 0.230159E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.352781E+09 0.213820E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.403836E+09 0.243791E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.350850E+09 0.171263E+10 71605.90 0.00 0.00 0.00 0.00 0.00
October 0.368514E+09 0.424940E+09 0.301224E+09 0.00 0.00 0.00 0.00 0.00
November 0.372765E+09 0.107362E+09 0.543407E+09 0.00 0.00 0.00 0.00 0.00
December 0.427926E+09 0.00 0.145028E+10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.463819E+10 0.100247E+11 0.589543E+10 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.350850E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.427936E+09 0.243791E+10 0.145028E+10 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: PSZ-AC:4

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.504746E+09 0.00 0.270847E+10 0.00 0.00 0.00 0.00 0.00
February 0.463600E+09 0.00 0.284612E+10 0.00 0.00 0.00 0.00 0.00
March 0.503189E+09 31825065.13 0.176465E+10 0.00 0.00 0.00 0.00 0.00
April 0.424280E+09 14774713.13 0.103698E+10 0.00 0.00 0.00 0.00 0.00
May 0.442168E+09 0.462804E+09 0.118670E+09 0.00 0.00 0.00 0.00 0.00
June 0.442168E+09 0.255850E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.401971E+09 0.252095E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.462266E+09 0.264204E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.401971E+09 0.179740E+10 414061.43 0.00 0.00 0.00 0.00 0.00
October 0.422790E+09 0.256834E+09 0.560057E+09 0.00 0.00 0.00 0.00 0.00
November 0.425382E+09 33728597.98 0.127573E+10 0.00 0.00 0.00 0.00 0.00
December 0.516626E+09 0.00 0.307290E+10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.541116E+10 0.103189E+11 0.133840E+11 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.401971E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.516626E+09 0.264204E+10 0.307290E+10 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: PSZ-AC:5

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.516607E+09 31536351.69 0.106681E+10 0.00 0.00 0.00 0.00 0.00
February 0.481946E+09 7122130.29 0.119363E+10 0.00 0.00 0.00 0.00 0.00
March 0.544357E+09 0.161701E+09 0.781241E+09 0.00 0.00 0.00 0.00 0.00
April 0.465650E+09 0.110449E+09 0.483925E+09 0.00 0.00 0.00 0.00 0.00
May 0.496790E+09 0.563312E+09 50142963.14 0.00 0.00 0.00 0.00 0.00
June 0.499044E+09 0.211329E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.454800E+09 0.195345E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.521231E+09 0.220129E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.453318E+09 0.163688E+10 85166.66 0.00 0.00 0.00 0.00 0.00
October 0.474446E+09 0.500328E+09 0.276067E+09 0.00 0.00 0.00 0.00 0.00
November 0.478394E+09 0.147120E+09 0.496021E+09 0.00 0.00 0.00 0.00 0.00
December 0.543019E+09 18148145.72 0.138386E+10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.592960E+10 0.944463E+10 0.573178E+10 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.453318E+09 7122130.29 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.544357E+09 0.220129E+10 0.138386E+10 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: PSZ-AC:1

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.435815E+09 0.00 0.00 0.224713E+09 11998903.66 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.394308E+09 0.00 0.00 0.254997E+09 584021.14 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.477321E+09 0.00 0.00 0.102412E+09 69941823.92 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.415061E+09 0.00 0.00 72081200.93 52695084.32 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.456568E+09 0.00 0.00 2078281.00 0.286650E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.456568E+09 0.00 0.00 0.00 0.827656E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.415061E+09 0.00 0.00 0.00 0.809955E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.477321E+09 0.00 0.00 0.00 0.874269E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.415061E+09 0.00 0.00 1193195.39 0.622703E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.435815E+09 0.00 0.00 72111680.45 0.218903E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.435815E+09 0.00 0.00 0.115504E+09 56922133.14 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.415061E+09 0.00 0.00 0.105112E+09 2486640.31 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.522977E+10 0.00 0.00 0.950202E+09 0.383476E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.394308E+09 0.00 0.00 0.00 584021.14 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.477321E+09 0.00 0.00 0.254997E+09 0.874269E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: PSZ-AC:2

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.478097E+09 0.00 0.00 0.458364E+09 85730881.96 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.471296E+09 0.00 0.00 0.698476E+09 40216714.72 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.542891E+09 0.00 0.00 0.591253E+09 0.113500E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.463147E+09 0.00 0.00 0.411272E+09 38196273.41 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.495282E+09 0.00 0.00 69601119.65 0.127030E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.495282E+09 0.00 0.00 0.00 0.660016E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.450257E+09 0.00 0.00 0.00 0.650886E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.517795E+09 0.00 0.00 0.00 0.810594E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.454457E+09 0.00 0.00 5953017.15 0.688554E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.475147E+09 0.00 0.00 0.306926E+09 0.304464E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.472770E+09 0.00 0.00 0.384628E+09 0.168983E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.504528E+09 0.00 0.00 0.285705E+09 64241713.86 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.582095E+10 0.00 0.00 0.321218E+10 0.375241E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.450257E+09 0.00 0.00 0.00 38196273.41 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.542891E+09 0.00 0.00 0.698476E+09 0.810594E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: PSZ-AC:3

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.410078E+09 0.00 0.00 0.532956E+09 571310.75 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.387229E+09 0.00 0.00 0.598093E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.427936E+09 0.00 0.00 0.373643E+09 32432827.81 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.364401E+09 0.00 0.00 0.223652E+09 33212027.97 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.385935E+09 0.00 0.00 14788507.05 0.139119E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.385935E+09 0.00 0.00 0.00 0.551474E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.352781E+09 0.00 0.00 0.00 0.506272E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.403836E+09 0.00 0.00 0.00 0.571877E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.350850E+09 0.00 0.00 1353723.07 0.390648E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.368514E+09 0.00 0.00 0.189466E+09 95128323.93 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.372765E+09 0.00 0.00 0.312705E+09 24112344.71 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.427926E+09 0.00 0.00 0.305124E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.463819E+10 0.00 0.00 0.255178E+10 0.234485E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.350850E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.427936E+09 0.00 0.00 0.598093E+09 0.571877E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: PSZ-AC:4

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.504746E+09 0.00 0.00 0.111235E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.463600E+09 0.00 0.00 0.112712E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.503189E+09 0.00 0.00 0.775058E+09 7261965.61 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.424280E+09 0.00 0.00 0.431513E+09 3353378.03 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.442168E+09 0.00 0.00 44447320.56 0.107506E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.442168E+09 0.00 0.00 0.00 0.618829E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.401971E+09 0.00 0.00 0.00 0.594521E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.462266E+09 0.00 0.00 0.00 0.626447E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.401971E+09 0.00 0.00 1533117.46 0.413450E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.422790E+09 0.00 0.00 0.285964E+09 58335597.66 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.425382E+09 0.00 0.00 0.612968E+09 7599586.85 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.516626E+09 0.00 0.00 0.671074E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.541116E+10 0.00 0.00 0.506203E+10 0.243730E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.401971E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.516626E+09 0.00 0.00 0.112712E+10 0.626447E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: PSZ-AC:5

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.516607E+09 0.00 0.00 0.531795E+09 7111934.99 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.481946E+09 0.00 0.00 0.608163E+09 1616932.61 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.544357E+09 0.00 0.00 0.408115E+09 36346136.53 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.465650E+09 0.00 0.00 0.250360E+09 24896285.94 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.496790E+09 0.00 0.00 20537308.14 0.130427E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.499044E+09 0.00 0.00 0.00 0.526049E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.454800E+09 0.00 0.00 0.00 0.476196E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.521231E+09 0.00 0.00 0.00 0.536615E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.453318E+09 0.00 0.00 1365024.81 0.383044E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.474446E+09 0.00 0.00 0.187047E+09 0.111852E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.478394E+09 0.00 0.00 0.301105E+09 32934312.22 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.543019E+09 0.00 0.00 0.303745E+09 4111201.29 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.592960E+10 0.00 0.00 0.261223E+10 0.227120E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.453318E+09 0.00 0.00 0.00 1616932.61 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.544357E+09 0.00 0.00 0.608163E+09 0.536615E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.120639E+10 0.00 0.00 347358.43 0.00 0.363869E+09 0.131453E+09 0.00 0.19
February 0.120049E+10 0.00 0.00 35598.26 0.00 0.392330E+09 21861247.65 0.00 0.19
March 0.116751E+10 0.00 0.00 1848586.35 0.00 0.150375E+09 0.297589E+09 0.00 0.21
April 0.868167E+09 0.00 0.00 1339852.55 0.00 0.112155E+09 0.312300E+09 0.00 0.19
May 0.427437E+09 0.00 0.00 5984112.69 0.00 749714.43 0.600828E+09 0.00 0.20
June 0.110367E+09 16200187.77 0.00 13999832.64 1300347.16 0.00 0.225121E+09 0.00 0.21
July 73571277.64 43230760.01 0.00 11368165.70 1379790.75 0.00 0.164416E+09 0.00 0.18
August 96642237.37 17160744.56 0.00 17406267.73 557706.30 0.00 0.286432E+09 0.00 0.21
September 0.166072E+09 0.00 0.00 14319546.40 0.00 0.00 0.483550E+09 0.00 0.19
October 0.778219E+09 0.00 0.00 6100093.17 0.00 44082981.29 0.661305E+09 0.00 0.19
November 0.123324E+10 0.00 0.00 1600666.43 0.00 0.101238E+09 0.340247E+09 0.00 0.20
December 0.136372E+10 0.00 0.00 93538.36 0.00 0.366921E+09 46445427.98 0.00 0.18
                   
Annual Sum or Average 0.869183E+10 76591692.34 0.00 74443618.71 3237844.21 0.153172E+10 0.357155E+10 0.00 0.19
Minimum of Months 73571277.64 0.00 0.00 35598.26 0.00 0.00 21861247.65 0.00 0.18
Maximum of Months 0.136372E+10 43230760.01 0.00 17406267.73 1379790.75 0.392330E+09 0.661305E+09 0.00 0.21



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.335970E+09 0.00 0.00 1982767.28 0.00 0.480939E+09 0.171199E+09 0.00 0.19
February 0.336307E+09 0.00 0.00 1031614.02 0.00 0.554761E+09 0.148649E+09 0.00 0.21
March 0.291196E+09 0.00 0.00 2430503.74 0.00 0.468387E+09 0.138004E+09 0.00 0.22
April 0.243630E+09 0.00 0.00 752774.25 0.00 0.345025E+09 66167499.01 0.00 0.19
May 0.249719E+09 1963898.31 0.00 1439185.92 130574.39 82689345.84 0.127701E+09 0.00 0.20
June 57280900.26 89958652.96 0.00 3732474.44 8337065.41 0.00 48458895.83 0.00 0.20
July 52938121.77 91850288.89 0.00 3366371.43 5546845.08 0.00 32589689.91 0.00 0.18
August 74736535.15 72391364.06 0.00 6982544.96 5559596.40 0.00 71549805.47 0.00 0.21
September 0.116907E+09 14758249.70 0.00 10133350.20 872381.05 3939812.99 0.127172E+09 0.00 0.19
October 0.243729E+09 0.00 0.00 7418973.97 0.00 0.264458E+09 0.272271E+09 0.00 0.19
November 0.386462E+09 0.00 0.00 4239945.81 0.00 0.324075E+09 0.218852E+09 0.00 0.20
December 0.287262E+09 0.00 0.00 1513934.83 0.00 0.780771E+09 0.145205E+09 0.00 0.20
                   
Annual Sum or Average 0.267614E+10 0.270922E+09 0.00 45024440.85 20446462.32 0.330505E+10 0.156782E+10 0.00 0.20
Minimum of Months 52938121.77 0.00 0.00 752774.25 0.00 0.00 32589689.91 0.00 0.18
Maximum of Months 0.386462E+09 91850288.89 0.00 10133350.20 8337065.41 0.780771E+09 0.272271E+09 0.00 0.22



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.116743E+09 0.00 0.00 1027.53 0.00 0.526063E+09 889808.03 0.00 0.21
February 0.126512E+09 0.00 0.00 0.00 0.00 0.518272E+09 0.00 0.00 0.22
March 0.182135E+09 0.00 0.00 655161.97 0.00 0.305529E+09 54281851.54 0.00 0.22
April 0.165865E+09 0.00 0.00 714788.83 0.00 0.181300E+09 59890384.64 0.00 0.19
May 0.123547E+09 855830.30 0.00 2335780.83 18494.50 24209603.77 0.145336E+09 0.00 0.20
June 28380773.32 56157831.22 0.00 4453904.60 3072119.79 0.00 30432828.74 0.00 0.20
July 22203460.87 64788502.00 0.00 3362497.08 2819814.49 0.00 26610786.35 0.00 0.18
August 31441812.63 44213949.18 0.00 6413218.04 2099724.16 0.00 53051418.88 0.00 0.21
September 65109801.87 6815279.93 0.00 6716745.88 220972.61 94979.96 89812914.75 0.00 0.19
October 0.160414E+09 0.00 0.00 2161881.99 0.00 0.158485E+09 0.151923E+09 0.00 0.19
November 0.183688E+09 0.00 0.00 457904.75 0.00 0.315485E+09 55027654.11 0.00 0.20
December 0.113783E+09 0.00 0.00 0.00 0.00 0.664025E+09 0.00 0.00 0.22
                   
Annual Sum or Average 0.131982E+10 0.172831E+09 0.00 27272911.51 8231125.54 0.269346E+10 0.667257E+09 0.00 0.20
Minimum of Months 22203460.87 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.18
Maximum of Months 0.183688E+09 64788502.00 0.00 6716745.88 3072119.79 0.664025E+09 0.151923E+09 0.00 0.22



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 86771164.98 0.00 0.00 0.00 0.00 0.110024E+10 0.00 0.00 0.22
February 32278822.89 0.00 0.00 0.00 0.00 0.113334E+10 0.00 0.00 0.23
March 0.191046E+09 0.00 0.00 93208.08 0.00 0.748076E+09 20771113.91 0.00 0.22
April 0.240868E+09 0.00 0.00 72545.37 0.00 0.450661E+09 16414248.31 0.00 0.19
May 0.268526E+09 438124.63 0.00 1448220.08 14553.74 70723048.41 0.190333E+09 0.00 0.20
June 57419645.98 59913592.06 0.00 5118072.83 4491706.40 0.00 62773087.38 0.00 0.20
July 48771270.75 73997369.86 0.00 4153468.56 3920050.69 0.00 44276025.91 0.00 0.18
August 72309627.52 42297785.18 0.00 7472011.08 3146211.35 0.00 0.101750E+09 0.00 0.21
September 0.127059E+09 1675850.57 0.00 7162011.07 285418.94 157788.24 0.167681E+09 0.00 0.19
October 0.376281E+09 0.00 0.00 1018191.87 0.00 0.297360E+09 0.149499E+09 0.00 0.19
November 0.245751E+09 0.00 0.00 132689.78 0.00 0.675165E+09 24376391.34 0.00 0.20
December 74749153.38 0.00 0.00 0.00 0.00 0.132833E+10 0.00 0.00 0.23
                   
Annual Sum or Average 0.182183E+10 0.178323E+09 0.00 26670418.70 11857941.12 0.580406E+10 0.777874E+09 0.00 0.20
Minimum of Months 32278822.89 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.18
Maximum of Months 0.376281E+09 73997369.86 0.00 7472011.08 4491706.40 0.132833E+10 0.190333E+09 0.00 0.23



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.156001E+09 0.00 0.00 123422.52 0.00 0.479126E+09 18428459.02 0.00 0.20
February 0.143600E+09 0.00 0.00 33405.70 0.00 0.490889E+09 9068442.90 0.00 0.21
March 0.158986E+09 0.00 0.00 619736.57 0.00 0.346578E+09 52865525.38 0.00 0.22
April 0.174024E+09 0.00 0.00 348436.39 0.00 0.196830E+09 48836784.60 0.00 0.19
May 0.151578E+09 526622.18 0.00 1603506.83 11458.11 32178539.70 0.133661E+09 0.00 0.20
June 35789873.61 38934979.15 0.00 3572313.44 1523375.92 0.00 35158756.78 0.00 0.21
July 27998232.02 48955462.15 0.00 2935214.97 1845686.03 0.00 27296327.50 0.00 0.18
August 40771572.59 28129647.49 0.00 5242100.03 859217.05 0.00 63561536.76 0.00 0.21
September 74717602.84 1497909.65 0.00 5829215.39 34372.11 95733.04 0.102853E+09 0.00 0.19
October 0.184301E+09 0.00 0.00 2129918.41 0.00 0.160319E+09 0.155408E+09 0.00 0.19
November 0.204408E+09 0.00 0.00 607633.80 0.00 0.309188E+09 64358000.55 0.00 0.20
December 0.145125E+09 0.00 0.00 61231.28 0.00 0.632872E+09 13272500.89 0.00 0.21
                   
Annual Sum or Average 0.149730E+10 0.118045E+09 0.00 23106135.34 4274109.22 0.264808E+10 0.724769E+09 0.00 0.20
Minimum of Months 27998232.02 0.00 0.00 33405.70 0.00 0.00 9068442.90 0.00 0.18
Maximum of Months 0.204408E+09 48955462.15 0.00 5829215.39 1845686.03 0.632872E+09 0.155408E+09 0.00 0.22



Table of Contents

Report: HeatEmissionsReportMonthly

For: Environment

Timestamp: 2023-10-16 08:29:19

Custom Monthly Report

SITE TOTAL SURFACE HEAT EMISSION TO AIR [J] SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J]
January 0.510281E+11 0.211584E+10 0.00 0.129272E+11 -986715182.0
February 0.690233E+11 0.324974E+10 0.00 0.121853E+11 -0.217569E+10
March 0.920848E+11 0.404749E+10 0.00 0.112393E+11 -401776226.0
April 0.101417E+12 0.425737E+10 0.00 0.100470E+11 -370485019.8
May 0.125760E+12 0.437605E+10 0.00 0.724090E+10 0.403781E+10
June 0.138276E+12 0.393274E+10 0.00 0.328715E+10 0.164217E+11
July 0.127725E+12 0.348526E+10 0.00 0.282584E+10 0.159738E+11
August 0.124779E+12 0.357828E+10 0.00 0.315937E+10 0.180131E+11
September 0.892086E+11 0.287817E+10 0.00 0.559500E+10 0.135724E+11
October 0.698789E+11 0.320588E+10 0.00 0.114950E+11 0.408811E+10
November 0.571775E+11 0.259364E+10 0.00 0.124264E+11 0.900376E+09
December 0.382224E+11 0.294646E+10 0.00 0.139367E+11 78081947.96
           
Annual Sum or Average 0.108458E+13 0.406669E+11 0.00 0.106365E+12 0.691507E+11
Minimum of Months 0.382224E+11 0.211584E+10 0.00 0.282584E+10 -0.217569E+10
Maximum of Months 0.138276E+12 0.437605E+10 0.00 0.139367E+11 0.180131E+11