Table of Contents

Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 08:29

Tabular Output Report in Format: HTML

Building: OfficeSmall

Environment: RUNPERIOD 1 ** El Paso International Ap Ut TX USA TMY3 WMO#=722700

Simulation Timestamp: 2023-10-16 08:29:45


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 155.97 305.12 305.12
Net Site Energy 155.97 305.12 305.12
Total Source Energy 493.54 965.53 965.53
Net Source Energy 493.54 965.53 965.53


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 1.200
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil No 1 1.050
Fuel Oil No 2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 511.16
Net Conditioned Building Area 511.16
Unconditioned Building Area 0.00


End Uses

Electricity [GJ] Natural Gas [GJ] Gasoline [GJ] Diesel [GJ] Coal [GJ] Fuel Oil No 1 [GJ] Fuel Oil No 2 [GJ] Propane [GJ] Other Fuel 1 [GJ] Other Fuel 2 [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 2.03 0.19 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 22.80 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 26.52 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 9.71 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 48.30 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 22.99 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 23.43 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 58.31
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                           
Total End Uses 155.77 0.19 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 58.31
Note: Electricity appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Gasoline [GJ] Diesel [GJ] Coal [GJ] Fuel Oil No 1 [GJ] Fuel Oil No 2 [GJ] Propane [GJ] Other Fuel 1 [GJ] Other Fuel 2 [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating General 2.03 0.19 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling General 22.80 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting LightsWired 26.52 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 9.71 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 48.30 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans General 22.99 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  Water Heater 23.43 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 29.16
  WaterUse 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 29.16
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


End Uses By Space Type

Space Type Electricity [GJ] Natural Gas [GJ] Gasoline [GJ] Diesel [GJ] Coal [GJ] Fuel Oil No 1 [GJ] Fuel Oil No 2 [GJ] Propane [GJ] Other Fuel 1 [GJ] Other Fuel 2 [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating Unassigned 2.03 0.19 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling Unassigned 22.80 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting GENERAL 26.52 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting Unassigned 9.71 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment GENERAL 48.30 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans Unassigned 22.99 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Unassigned 23.43 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 58.31
Refrigeration Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Gasoline Intensity [MJ/m2] Diesel Intensity [MJ/m2] Coal Intensity [MJ/m2] Fuel Oil No 1 Intensity [MJ/m2] Fuel Oil No 2 Intensity [MJ/m2] Propane Intensity [MJ/m2] Other Fuel 1 Intensity [MJ/m2] Other Fuel 2 Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 70.88 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
HVAC 139.38 0.38 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.11
Other 94.48 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total 304.74 0.38 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.11


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Gasoline Intensity [MJ/m2] Diesel Intensity [MJ/m2] Coal Intensity [MJ/m2] Fuel Oil No 1 Intensity [MJ/m2] Fuel Oil No 2 Intensity [MJ/m2] Propane Intensity [MJ/m2] Other Fuel 1 Intensity [MJ/m2] Other Fuel 2 Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 70.88 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
HVAC 139.38 0.38 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.11
Other 94.48 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total 304.74 0.38 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.11


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.000 0.00
High Temperature Geothermal* 0.000 0.00
Photovoltaic Power 0.000 0.00
Wind Power 0.000 0.00
Power Conversion 0.000 0.00
Net Decrease in On-Site Storage 0.000 0.00
Total On-Site Electric Sources 0.000 0.00
     
Electricity Coming From Utility 155.772 100.00
Surplus Electricity Going To Utility 0.000 0.00
Net Electricity From Utility 155.772 100.00
     
Total On-Site and Utility Electric Sources 155.772 100.00
Total Electricity End Uses 155.772 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 58.31 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 58.31 100.00
Total Water End Uses 58.31 100.00


Setpoint Not Met Criteria

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.56
Tolerance for Zone Cooling Setpoint Not Met Time 0.56


Comfort and Setpoint Not Met Summary

Facility [Hours]
Time Setpoint Not Met During Occupied Heating 0.00
Time Setpoint Not Met During Occupied Cooling 122.83
Time Not Comfortable Based on Simple ASHRAE 55-2004 1510.83


Note 1: An asterisk (*) indicates that the feature is not yet implemented.

Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Adaptive Comfort Summary
Initialization Summary
Annual Heat Emissions Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
Coil Sizing Details
System Summary
Outdoor Air Summary
Outdoor Air Details
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary
Annual Thermal Resilience Summary
Annual CO2 Resilience Summary
Annual Visual Resilience Summary

NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR

| Environment |

NAMEHOLDERMONTHLYSUMMARY CODENAME IECC

| Environment |

NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2021

| Environment |

NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND

| Environment |

NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME OFFICESMALL

| Environment |

NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL

| Environment |

NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL

| Environment |

NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 3B

| Environment |

NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_TX_ELPASO

| Environment |

ZoneCoolingSummaryMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

ZoneHeatingSummaryMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

ZoneElectricSummaryMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 |

SpaceGainsMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

PeakSpaceGainsMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

SpaceGainComponentsAtCoolingPeakMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

EnergyConsumptionElectricityNaturalGasMonthly

| Meter |

EndUseEnergyConsumptionElectricityMonthly

| Meter |

EndUseEnergyConsumptionNaturalGasMonthly

| Meter |

PeakEnergyEndUseElectricityPart1Monthly

| Meter |

PeakEnergyEndUseElectricityPart2Monthly

| Meter |

ElectricComponentsOfPeakDemandMonthly

| Meter |

PeakEnergyEndUseNaturalGasMonthly

| Meter |

SetpointsNotMetWithTemperaturesMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

ComfortReportSimple55Monthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

OccupantComfortDataSummaryMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 |

DXReportMonthly

| PSZ-AC:1 HP COOLING COIL | PSZ-AC:2 HP COOLING COIL | PSZ-AC:3 HP COOLING COIL | PSZ-AC:4 HP COOLING COIL | PSZ-AC:5 HP COOLING COIL |

WindowReportMonthly

| PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 | PERIMETER_ZN_1_WALL_SOUTH_DOOR | PERIMETER_ZN_2_WALL_EAST_WINDOW_4 | PERIMETER_ZN_2_WALL_EAST_WINDOW_3 | PERIMETER_ZN_2_WALL_EAST_WINDOW_2 | PERIMETER_ZN_2_WALL_EAST_WINDOW_1 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 | PERIMETER_ZN_4_WALL_WEST_WINDOW_4 | PERIMETER_ZN_4_WALL_WEST_WINDOW_3 | PERIMETER_ZN_4_WALL_WEST_WINDOW_2 | PERIMETER_ZN_4_WALL_WEST_WINDOW_1 |

WindowEnergyReportMonthly

| PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 | PERIMETER_ZN_1_WALL_SOUTH_DOOR | PERIMETER_ZN_2_WALL_EAST_WINDOW_4 | PERIMETER_ZN_2_WALL_EAST_WINDOW_3 | PERIMETER_ZN_2_WALL_EAST_WINDOW_2 | PERIMETER_ZN_2_WALL_EAST_WINDOW_1 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 | PERIMETER_ZN_4_WALL_WEST_WINDOW_4 | PERIMETER_ZN_4_WALL_WEST_WINDOW_3 | PERIMETER_ZN_4_WALL_WEST_WINDOW_2 | PERIMETER_ZN_4_WALL_WEST_WINDOW_1 |

WindowZoneSummaryMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

WindowEnergyZoneSummaryMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

AverageOutdoorConditionsMonthly

| Environment |

OutdoorConditionsMaximumDryBulbMonthly

| Environment |

OutdoorConditionsMinimumDryBulbMonthly

| Environment |

OutdoorConditionsMaximumWetBulbMonthly

| Environment |

OutdoorConditionsMaximumDewPointMonthly

| Environment |

OutdoorGroundConditionsMonthly

| Environment |

WaterHeaterReportMonthly

| SWHSYS1 WATER HEATER |

DaylightingReportMonthly

| PERIMETER_ZN_1_DAYLCTRL | PERIMETER_ZN_2_DAYLCTRL | PERIMETER_ZN_3_DAYLCTRL | PERIMETER_ZN_4_DAYLCTRL |

CoilReportMonthly

| PSZ-AC:1 HEATING COIL | PSZ-AC:2 HEATING COIL | PSZ-AC:3 HEATING COIL | PSZ-AC:4 HEATING COIL | PSZ-AC:5 HEATING COIL | PSZ-AC:1_SUPPHEATCOIL | PSZ-AC:2_SUPPHEATCOIL | PSZ-AC:3_SUPPHEATCOIL | PSZ-AC:4_SUPPHEATCOIL | PSZ-AC:5_SUPPHEATCOIL | PSZ-AC:1 HP COOLING COIL | PSZ-AC:2 HP COOLING COIL | PSZ-AC:3 HP COOLING COIL | PSZ-AC:4 HP COOLING COIL | PSZ-AC:5 HP COOLING COIL |

PlantLoopDemandReportMonthly

| SWHSYS1 |

FanReportMonthly

| PSZ-AC:1 FAN | PSZ-AC:2 FAN | PSZ-AC:3 FAN | PSZ-AC:4 FAN | PSZ-AC:5 FAN |

PumpReportMonthly

| SWHSYS1 PUMP |

CondLoopDemandReportMonthly

| SWHSYS1 |

ZoneTemperatureOscillationReportMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

AirLoopSystemEnergyAndWaterUseMonthly

| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 | PSZ-AC:5 |

AirLoopSystemComponentLoadsMonthly

| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 | PSZ-AC:5 |

AirLoopSystemComponentEnergyUseMonthly

| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 | PSZ-AC:5 |

MechanicalVentilationLoadsMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 |

HeatEmissionsReportMonthly

| Environment |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

General

Value
Program Version and Build EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 08:29
RunPeriod RUNPERIOD 1
Weather File El Paso International Ap Ut TX USA TMY3 WMO#=722700
Latitude [deg] 31.77
Longitude [deg] -106.5
Elevation [m] 1186.00
Time Zone -7.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 281.51 84.45 56.30 84.45 56.30
Above Ground Wall Area [m2] 281.51 84.45 56.30 84.45 56.30
Window Opening Area [m2] 59.65 16.72 11.15 20.63 11.15
Gross Window-Wall Ratio [%] 21.19 19.80 19.80 24.43 19.80
Above Ground Window-Wall Ratio [%] 21.19 19.80 19.80 24.43 19.80


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 281.51 84.45 56.30 84.45 56.30
Above Ground Wall Area [m2] 281.51 84.45 56.30 84.45 56.30
Window Opening Area [m2] 59.65 16.72 11.15 20.63 11.15
Gross Window-Wall Ratio [%] 21.19 19.80 19.80 24.43 19.80
Above Ground Window-Wall Ratio [%] 21.19 19.80 19.80 24.43 19.80


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 598.76
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Above Ground Gross Wall Area [m2] Underground Gross Wall Area [m2] Window Glass Area [m2] Opening Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
CORE_ZN 149.66 Yes Yes 456.46 1.00 0.00 0.00 0.00 0.00 6.0938 18.58 6.7800
PERIMETER_ZN_1 113.45 Yes Yes 346.02 1.00 84.45 0.00 20.63 20.63 6.0938 18.58 6.7800
PERIMETER_ZN_2 67.30 Yes Yes 205.26 1.00 56.30 0.00 11.15 11.15 6.0938 18.58 6.7800
PERIMETER_ZN_3 113.45 Yes Yes 346.02 1.00 84.45 0.00 16.72 16.72 6.0938 18.58 6.7800
PERIMETER_ZN_4 67.30 Yes Yes 205.26 1.00 56.30 0.00 11.15 11.15 6.0938 18.58 6.7800
ATTIC 567.98 No No 720.19 1.00 0.00 0.00 0.00 0.00 0.0000   0.0000
Total 511.16     1559.03   281.51 0.00 59.65 59.65 6.0938 18.58 6.7800
Conditioned Total 511.16     1559.03   281.51 0.00 59.65 59.65 6.0938 18.58 6.7800
Unconditioned Total 0.00     0.00   0.00 0.00 0.00 0.00      
Not Part of Total 567.98     720.19   0.00 0.00 0.00 0.00 0.0000   0.0000


Space Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Multipliers Zone Name Space Type Radiant/Solar Enclosure Name Lighting [W/m2] People [m2 per person] Plug and Process [W/m2] Tags
CORE_ZN 149.66 Yes Yes 1.00 CORE_ZN GENERAL CORE_ZN 6.0938 18.58 6.7800  
PERIMETER_ZN_1 113.45 Yes Yes 1.00 PERIMETER_ZN_1 GENERAL PERIMETER_ZN_1 6.0938 18.58 6.7800  
PERIMETER_ZN_2 67.30 Yes Yes 1.00 PERIMETER_ZN_2 GENERAL PERIMETER_ZN_2 6.0938 18.58 6.7800  
PERIMETER_ZN_3 113.45 Yes Yes 1.00 PERIMETER_ZN_3 GENERAL PERIMETER_ZN_3 6.0938 18.58 6.7800  
PERIMETER_ZN_4 67.30 Yes Yes 1.00 PERIMETER_ZN_4 GENERAL PERIMETER_ZN_4 6.0938 18.58 6.7800  
ATTIC 567.98 No No 1.00 ATTIC GENERAL ATTIC 0.0000 0.00 0.0000  
Total 511.16             6.0938 9.29 6.7800  
Conditioned Total 511.16             6.0938 9.29 6.7800  
Unconditioned Total 0.00             0.0000 0.00 0.0000  
Not Part of Total 567.98             0.0000 0.00 0.0000  


Space Type Summary

Total Area [m2] Conditioned Area [m2] Unconditioned Area [m2] Not Part of Total Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
GENERAL 511.16 511.16 0.00 567.98 6.0938 18.58 6.7800
Total 511.16 511.16 0.00 567.98      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

End Uses

Electricity [W] Natural Gas [W] Gasoline [W] Diesel [W] Coal [W] Fuel Oil No 1 [W] Fuel Oil No 2 [W] Propane [W] Other Fuel 1 [W] Other Fuel 2 [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 07-AUG-15:39 27-DEC-07:10 - - - - - - - - - - 02-JAN-12:09
Heating 0.00 8979.90 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 6975.26 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 1729.33 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 3325.31 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 1944.98 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 2725.73 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                           
Total End Uses 16700.61 8979.90 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Gasoline [W] Diesel [W] Coal [W] Fuel Oil No 1 [W] Fuel Oil No 2 [W] Propane [W] Other Fuel 1 [W] Other Fuel 2 [W] District Cooling [W] Steam [W] Water [m3/s]
Heating General 0.00 8979.90 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling General 6975.26 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting LightsWired 1729.33 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 3325.31 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans General 1944.98 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  Water Heater 2725.73 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  WaterUse 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Gasoline [GJ] Source Diesel [GJ] Source Coal [GJ] Source Fuel Oil No 1 [GJ] Source Fuel Oil No 2 [GJ] Source Propane [GJ] Source Other Fuel 1 [GJ] Source Other Fuel 2 [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 6.43 0.21 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 72.19 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 83.98 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 30.76 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 152.95 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 72.80 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 74.21 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Total Source Energy End Use Components 493.33 0.21 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Gasoline [MJ/m2] Source Diesel [MJ/m2] Source Coal [MJ/m2] Source Fuel Oil No 1 [MJ/m2] Source Fuel Oil No 2 [MJ/m2] Source Propane [MJ/m2] Source Other Fuel 1 [MJ/m2] Source Other Fuel 2 [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 12.58 0.41 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 141.23 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 164.29 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 60.18 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 299.23 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 142.42 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 145.18 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Total Source Energy End Use Components 965.13 0.41 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Gasoline [MJ/m2] Source Diesel [MJ/m2] Source Coal [MJ/m2] Source Fuel Oil No 1 [MJ/m2] Source Fuel Oil No 2 [MJ/m2] Source Propane [MJ/m2] Source Other Fuel 1 [MJ/m2] Source Other Fuel 2 [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 12.58 0.41 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 141.23 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 164.29 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 60.18 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 299.23 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 142.42 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 145.18 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Total Source Energy End Use Components 965.13 0.41 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

AirTerminal:SingleDuct:ConstantVolume:NoReheat

Design Size Maximum Air Flow Rate [m3/s]
CORE_ZN DIRECT AIR 0.337639
PERIMETER_ZN_1 DIRECT AIR 0.388686
PERIMETER_ZN_2 DIRECT AIR 0.283588
PERIMETER_ZN_3 DIRECT AIR 0.383626
PERIMETER_ZN_4 DIRECT AIR 0.342883
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

AirLoopHVAC

Sum of Air Terminal Maximum Heating Flow Rates [m3/s] Sum of Air Terminal Minimum Heating Flow Rates [m3/s] Sum of Air Terminal Maximum Flow Rates [m3/s] Adjusted Heating Design Air Flow Rate [m3/s] Adjusted Cooling Design Air Flow Rate [m3/s] Adjusted Main Design Air Flow Rate [m3/s] User Heating Air Flow Ratio [] Calculated Heating Air Flow Ratio [] Design Supply Air Flow Rate [m3/s]
PSZ-AC:1 0.337639 0.337639 0.337639 0.337639 0.337639 0.337639 1.00 1.00 0.337639
PSZ-AC:2 0.388686 0.388686 0.388686 0.388686 0.388686 0.388686 1.00 1.00 0.388686
PSZ-AC:3 0.283588 0.283588 0.283588 0.283588 0.283588 0.283588 1.00 1.00 0.283588
PSZ-AC:4 0.383626 0.383626 0.383626 0.383626 0.383626 0.383626 1.00 1.00 0.383626
PSZ-AC:5 0.342883 0.342883 0.342883 0.342883 0.342883 0.342883 1.00 1.00 0.342883
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
PSZ-AC:1_OA_CONTROLLER 0.337639 0.064622
PSZ-AC:2_OA_CONTROLLER 0.388686 0.048988
PSZ-AC:3_OA_CONTROLLER 0.283588 0.029060
PSZ-AC:4_OA_CONTROLLER 0.383626 0.048988
PSZ-AC:5_OA_CONTROLLER 0.342883 0.029060
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Coil:Cooling:DX:SingleSpeed

Design Size Rated Air Flow Rate [m3/s] Design Size Gross Rated Total Cooling Capacity [W] Design Size Gross Rated Sensible Heat Ratio
PSZ-AC:1 HP COOLING COIL 0.337639 5828.01 0.800585
PSZ-AC:2 HP COOLING COIL 0.388686 6434.13 0.800655
PSZ-AC:3 HP COOLING COIL 0.283588 4694.39 0.800655
PSZ-AC:4 HP COOLING COIL 0.383626 6350.37 0.800655
PSZ-AC:5 HP COOLING COIL 0.342883 5675.94 0.800655
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

AirLoopHVAC:UnitaryHeatPump:AirToAir

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Maximum Supply Air Temperature from Supplemental Heater [C] Supplemental Heating Coil Nominal Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
PSZ-AC:1_UNITARY_PACKAGE_DX 0.337639 0.337639 0.337639 0.337639 5828.01 5828.01 40.00 3065.23 1.00
PSZ-AC:2_UNITARY_PACKAGE_DX 0.388686 0.388686 0.388686 0.388686 6434.13 6434.13 40.00 4691.77 1.00
PSZ-AC:3_UNITARY_PACKAGE_DX 0.283588 0.283588 0.283588 0.283588 4694.39 4694.39 40.00 2933.47 1.00
PSZ-AC:4_UNITARY_PACKAGE_DX 0.383626 0.383626 0.383626 0.383626 6350.37 6350.37 40.00 4663.87 1.00
PSZ-AC:5_UNITARY_PACKAGE_DX 0.342883 0.342883 0.342883 0.342883 5675.94 5675.94 40.00 2917.89 1.00
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Fan:OnOff

Design Size Maximum Flow Rate [m3/s]
PSZ-AC:1 FAN 0.337639
PSZ-AC:2 FAN 0.388686
PSZ-AC:3 FAN 0.283588
PSZ-AC:4 FAN 0.383626
PSZ-AC:5 FAN 0.342883
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Coil:Heating:DX:SingleSpeed

Design Size Rated Air Flow Rate [m3/s] Design Size Gross Rated Heating Capacity [W]
PSZ-AC:1 HEATING COIL 0.337639 5828.01
PSZ-AC:2 HEATING COIL 0.388686 6434.13
PSZ-AC:3 HEATING COIL 0.283588 4694.39
PSZ-AC:4 HEATING COIL 0.383626 6350.37
PSZ-AC:5 HEATING COIL 0.342883 5675.94
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Coil:Heating:Fuel

Design Size Nominal Capacity [W]
PSZ-AC:1_SUPPHEATCOIL 3065.23
PSZ-AC:2_SUPPHEATCOIL 4691.77
PSZ-AC:3_SUPPHEATCOIL 2933.47
PSZ-AC:4_SUPPHEATCOIL 4663.87
PSZ-AC:5_SUPPHEATCOIL 2917.89
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

PlantLoop

Maximum Loop Flow Rate [m3/s] Plant Loop Volume [m3]
SWHSYS1 0.000004 0.000486
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Pump:ConstantSpeed

Design Flow Rate [m3/s] Design Power Consumption [W]
SWHSYS1 PUMP 0.000004 0.000000
User-Specified values were used. Design Size values were used if no User-Specified values were provided.


Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

Possible Shadow Receivers
PERIMETER_ZN_1_WALL_SOUTH ATTIC_SOFFIT_WEST | ATTIC_SOFFIT_SOUTH | ATTIC_SOFFIT_EAST |
PERIMETER_ZN_2_WALL_EAST ATTIC_SOFFIT_SOUTH | ATTIC_SOFFIT_EAST | ATTIC_SOFFIT_NORTH |
PERIMETER_ZN_3_WALL_NORTH ATTIC_SOFFIT_WEST | ATTIC_SOFFIT_EAST | ATTIC_SOFFIT_NORTH |
PERIMETER_ZN_4_WALL_WEST ATTIC_SOFFIT_WEST | ATTIC_SOFFIT_SOUTH | ATTIC_SOFFIT_NORTH |


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
PERIMETER_ZN_1_WALL_SOUTH PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 | PERIMETER_ZN_1_WALL_SOUTH_DOOR |
PERIMETER_ZN_2_WALL_EAST PERIMETER_ZN_2_WALL_EAST_WINDOW_4 | PERIMETER_ZN_2_WALL_EAST_WINDOW_3 | PERIMETER_ZN_2_WALL_EAST_WINDOW_2 | PERIMETER_ZN_2_WALL_EAST_WINDOW_1 |
PERIMETER_ZN_3_WALL_NORTH PERIMETER_ZN_3_WALL_NORTH_DOOR1 | PERIMETER_ZN_3_WALL_NORTH_DOOR2 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 |
PERIMETER_ZN_4_WALL_WEST PERIMETER_ZN_4_WALL_WEST_WINDOW_4 | PERIMETER_ZN_4_WALL_WEST_WINDOW_3 | PERIMETER_ZN_4_WALL_WEST_WINDOW_2 | PERIMETER_ZN_4_WALL_WEST_WINDOW_1 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: Initialization Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

Version

Version ID
1 22.1


Timesteps per Hour

#TimeSteps Minutes per TimeStep {minutes}
1 6 10


System Convergence Limits

Minimum System TimeStep {minutes} Max HVAC Iterations Minimum Plant Iterations Maximum Plant Iterations
1 1 20 2 8


Simulation Control

Do Zone Sizing Do System Sizing Do Plant Sizing Do Design Days Do Weather Simulation Do HVAC Sizing Simulation
1 Yes Yes Yes No Yes No


Performance Precision Tradeoffs

Use Coil Direct Simulation Zone Radiant Exchange Algorithm Override Mode Number of Timestep In Hour Force Euler Method Minimum Number of Warmup Days Force Suppress All Begin Environment Resets Minimum System Timestep MaxZoneTempDiff MaxAllowedDelTemp
1 No ScriptF Normal 6 No 1 No 1.0 0.300 2.0000E-003


Output Reporting Tolerances

Tolerance for Time Heating Setpoint Not Met Tolerance for Zone Cooling Setpoint Not Met Time
1 0.556 0.556


Site:GroundTemperature:BuildingSurface

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00


Site:GroundTemperature:FCfactorMethod

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 18.30 11.20 6.80 8.10 10.30 12.50 19.20 23.80 27.90 27.50 26.30 23.40


Site:GroundTemperature:Shallow

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00


Site:GroundTemperature:Deep

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00


Site:GroundReflectance

Jan{dimensionless} Feb{dimensionless} Mar{dimensionless} Apr{dimensionless} May{dimensionless} Jun{dimensionless} Jul{dimensionless} Aug{dimensionless} Sep{dimensionless} Oct{dimensionless} Nov{dimensionless} Dec{dimensionless}
1 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20


Site:GroundReflectance:SnowModifier

Normal Daylighting {dimensionless}
1 1.000 1.000


Site:GroundReflectance:Snow

Jan{dimensionless} Feb{dimensionless} Mar{dimensionless} Apr{dimensionless} May{dimensionless} Jun{dimensionless} Jul{dimensionless} Aug{dimensionless} Sep{dimensionless} Oct{dimensionless} Nov{dimensionless} Dec{dimensionless}
1 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20


Site:GroundReflectance:Snow:Daylighting

Jan{dimensionless} Feb{dimensionless} Mar{dimensionless} Apr{dimensionless} May{dimensionless} Jun{dimensionless} Jul{dimensionless} Aug{dimensionless} Sep{dimensionless} Oct{dimensionless} Nov{dimensionless} Dec{dimensionless}
1 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20


Environment:Weather Station

Wind Sensor Height Above Ground {m} Wind Speed Profile Exponent {} Wind Speed Profile Boundary Layer Thickness {m} Air Temperature Sensor Height Above Ground {m} Wind Speed Modifier Coefficient-Internal Temperature Modifier Coefficient-Internal
1 10.000 0.140 270.000 1.500 1.586 9.750E-003


Site:Location

Location Name Latitude {N+/S- Deg} Longitude {E+/W- Deg} Time Zone Number {GMT+/-} Elevation {m} Standard Pressure at Elevation {Pa} Standard RhoAir at Elevation
1 El Paso International Ap Ut TX USA TMY3 WMO#=722700 31.77 -106.50 -7.00 1186.00 87865 1.0443


Site Water Mains Temperature Information

Calculation Method{} Water Mains Temperature Schedule Name{} Annual Average Outdoor Air Temperature{C} Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} Fixed Default Water Mains Temperature{C}
1 Correlation NA 17.94 21.10 NA


Building Information

Building Name North Axis {deg} Terrain Loads Convergence Tolerance Value Temperature Convergence Tolerance Value Solar Distribution Maximum Number of Warmup Days Minimum Number of Warmup Days
1 OfficeSmall 0.000 City 4.00000E-002 0.20000 FullInteriorAndExterior 25 6


Inside Convection Algorithm

Algorithm {Simple
TARP
CeilingDiffuser
AdaptiveConvectionAlgorithm}
1 TARP


Outside Convection Algorithm

Algorithm {SimpleCombined
TARP
MoWitt
DOE-2
AdaptiveConvectionAlgorithm}
1 TARP


Sky Radiance Distribution

Value {Anisotropic}
1 Anisotropic


Zone Air Solution Algorithm

Value {ThirdOrderBackwardDifference
AnalyticalSolution
EulerMethod}
1 ThirdOrderBackwardDifference


Zone Air Carbon Dioxide Balance Simulation

Simulation {Yes/No} Carbon Dioxide Concentration
1 No N/A


Zone Air Generic Contaminant Balance Simulation

Simulation {Yes/No} Generic Contaminant Concentration
1 No N/A


Zone Air Mass Flow Balance Simulation

Enforce Mass Balance



Adjust Zone Mixing and Return {AdjustMixingOnly
AdjustReturnOnly
AdjustMixingThenReturn
AdjustReturnThenMixing
None}
Adjust Zone Infiltration {AddInfiltration
AdjustInfiltration
None}

Infiltration Zones {MixingSourceZonesOnly
AllZones}


1 No N/A N/A N/A


HVACSystemRootFindingAlgorithm

Value {RegulaFalsi
Bisection
BisectionThenRegulaFalsi
RegulaFalsiThenBisection}
1 RegulaFalsi


Environment:Site Atmospheric Variation

Wind Speed Profile Exponent {} Wind Speed Profile Boundary Layer Thickness {m} Air Temperature Gradient Coefficient {K/m}
1 0.330 460.000 6.500000E-003


Surface Geometry

Starting Corner Vertex Input Direction Coordinate System Daylight Reference Point Coordinate System Rectangular (Simple) Surface Coordinate System
1 UpperLeftCorner Counterclockwise RelativeCoordinateSystem RelativeCoordinateSystem RelativeToZoneOrigin


Surface Heat Transfer Algorithm

Value {CTF - ConductionTransferFunction
EMPD - MoisturePenetrationDepthConductionTransferFunction
CondFD - ConductionFiniteDifference
HAMT - CombinedHeatAndMoistureFiniteElement} - Description
Inside Surface Max Temperature Limit{C}


Surface Convection Coefficient Lower Limit {W/m2-K}


Surface Convection Coefficient Upper Limit {W/m2-K}


1 CTF - ConductionTransferFunction 200 0.10 1000.0


Shading Summary

Number of Fixed Detached Shades Number of Building Detached Shades Number of Attached Shades
1 0 0 0


Zone Summary

Number of Zones Number of Zone Surfaces Number of SubSurfaces
1 6 71 23


Zone Information

Zone Name North Axis {deg} Origin X-Coordinate {m} Origin Y-Coordinate {m} Origin Z-Coordinate {m} Centroid X-Coordinate {m} Centroid Y-Coordinate {m} Centroid Z-Coordinate {m} Type Zone Multiplier Zone List Multiplier Minimum X {m} Maximum X {m} Minimum Y {m} Maximum Y {m} Minimum Z {m} Maximum Z {m} Ceiling Height {m} Volume {m3} Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} Floor Area {m2} Exterior Gross Wall Area {m2} Exterior Net Wall Area {m2} Exterior Window Area {m2} Number of Surfaces Number of SubSurfaces Number of Shading SubSurfaces Part of Total Building Area
1 CORE_ZN 0.0 0.00 0.00 0.00 13.85 9.23 1.53 1 1 1 5.00 22.69 5.00 13.46 0.00 3.05 3.05 456.46 TARP TARP 149.66 0.00 0.00 0.00 6 0 0 Yes
2 PERIMETER_ZN_1 0.0 0.00 0.00 0.00 13.85 2.21 1.53 1 1 1 0.00 27.69 0.00 5.00 0.00 3.05 3.05 346.02 TARP TARP 113.45 84.45 63.82 20.63 6 7 0 Yes
3 PERIMETER_ZN_2 0.0 0.00 0.00 0.00 25.64 9.23 1.53 1 1 1 22.69 27.69 0.00 18.46 0.00 3.05 3.05 205.27 TARP TARP 67.30 56.30 45.15 11.15 6 4 0 Yes
4 PERIMETER_ZN_3 0.0 0.00 0.00 0.00 13.85 16.25 1.53 1 1 1 0.00 27.69 13.46 18.46 0.00 3.05 3.05 346.02 TARP TARP 113.45 84.45 63.83 16.72 6 8 0 Yes
5 PERIMETER_ZN_4 0.0 0.00 0.00 0.00 2.05 9.23 1.53 1 1 1 0.00 5.00 0.00 18.46 0.00 3.05 3.05 205.27 TARP TARP 67.30 56.30 45.15 11.15 6 4 0 Yes
6 ATTIC 0.0 0.00 0.00 0.00 13.85 9.23 3.70 1 1 1 -0.60 28.29 -0.60 19.06 3.05 6.33 1.64 720.19 TARP TARP 567.98 0.00 0.00 0.00 13 0 0 No


Zone Internal Gains Nominal

Zone Name Floor Area {m2} # Occupants Area per Occupant {m2/person} Occupant per Area {person/m2} Interior Lighting {W/m2} Electric Load {W/m2} Gas Load {W/m2} Other Load {W/m2} Hot Water Eq {W/m2} Steam Equipment {W/m2} Sum Loads per Area {W/m2} Outdoor Controlled Baseboard Heat
1 CORE_ZN 149.66 8.1 18.581 5.382E-002 6.094 6.780 0.000 0.000 0.000 0.000 12.874 No
2 PERIMETER_ZN_1 113.45 6.1 18.581 5.382E-002 6.094 6.780 0.000 0.000 0.000 0.000 12.874 No
3 PERIMETER_ZN_2 67.30 3.6 18.581 5.382E-002 6.094 6.780 0.000 0.000 0.000 0.000 12.874 No
4 PERIMETER_ZN_3 113.45 6.1 18.581 5.382E-002 6.094 6.780 0.000 0.000 0.000 0.000 12.874 No
5 PERIMETER_ZN_4 67.30 3.6 18.581 5.382E-002 6.094 6.780 0.000 0.000 0.000 0.000 12.874 No
6 ATTIC 567.98 0.0 N/A 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 No


People Internal Gains Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Number of People {} People/Floor Area {person/m2} Floor Area per person {m2/person} Fraction Radiant Fraction Convected Sensible Fraction Calculation Activity level ASHRAE 55 Warnings Carbon Dioxide Generation Rate Nominal Minimum Number of People Nominal Maximum Number of People
1 CORE_ZN BLDG_OCC_SCH_WO_SB CORE_ZN 149.66 8.1 8.1 5.382E-002 18.581 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 8
2 PERIMETER_ZN_1 BLDG_OCC_SCH_WO_SB PERIMETER_ZN_1 113.45 6.1 6.1 5.382E-002 18.581 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 6
3 PERIMETER_ZN_2 BLDG_OCC_SCH_W_SB PERIMETER_ZN_2 67.30 3.6 3.6 5.382E-002 18.581 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 4
4 PERIMETER_ZN_3 BLDG_OCC_SCH_WO_SB PERIMETER_ZN_3 113.45 6.1 6.1 5.382E-002 18.581 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 6
5 PERIMETER_ZN_4 BLDG_OCC_SCH_WO_SB PERIMETER_ZN_4 67.30 3.6 3.6 5.382E-002 18.581 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 4


Lights Internal Gains Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Lighting Level {W} Lights/Floor Area {W/m2} Lights per person {W/person} Fraction Return Air Fraction Radiant Fraction Short Wave Fraction Convected Fraction Replaceable End-Use Category Nominal Minimum Lighting Level {W} Nominal Maximum Lighting Level {W}
1 CORE_ZN_LIGHTS LTG_SCH_OFFICE CORE_ZN 149.66 8.1 911.976 6.094 113.226 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 911.976
2 PERIMETER_ZN_1_LIGHTS LTG_SCH_OFFICE PERIMETER_ZN_1 113.45 6.1 691.337 6.094 113.226 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 691.337
3 PERIMETER_ZN_2_LIGHTS LTG_SCH_OFFICE PERIMETER_ZN_2 67.30 3.6 410.110 6.094 113.226 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 410.110
4 PERIMETER_ZN_3_LIGHTS LTG_SCH_OFFICE PERIMETER_ZN_3 113.45 6.1 691.337 6.094 113.226 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 691.337
5 PERIMETER_ZN_4_LIGHTS LTG_SCH_OFFICE PERIMETER_ZN_4 67.30 3.6 410.110 6.094 113.226 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 410.110


ElectricEquipment Internal Gains Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Equipment Level {W} Equipment/Floor Area {W/m2} Equipment per person {W/person} Fraction Latent Fraction Radiant Fraction Lost Fraction Convected End-Use SubCategory Nominal Minimum Equipment Level {W} Nominal Maximum Equipment Level {W}
1 CORE_ZN_MISCPLUG_EQUIP BLDG_EQUIP_SCH CORE_ZN 149.66 8.1 1014.677 6.780 125.977 0.000 0.000 0.000 1.000 MiscPlug 0.000 1014.677
2 PERIMETER_ZN_1_MISCPLUG_EQUIP BLDG_EQUIP_SCH PERIMETER_ZN_1 113.45 6.1 769.191 6.780 125.977 0.000 0.000 0.000 1.000 MiscPlug 0.000 769.191
3 PERIMETER_ZN_2_MISCPLUG_EQUIP BLDG_EQUIP_SCH PERIMETER_ZN_2 67.30 3.6 456.294 6.780 125.977 0.000 0.000 0.000 1.000 MiscPlug 0.000 456.294
4 PERIMETER_ZN_3_MISCPLUG_EQUIP BLDG_EQUIP_SCH PERIMETER_ZN_3 113.45 6.1 769.191 6.780 125.977 0.000 0.000 0.000 1.000 MiscPlug 0.000 769.191
5 PERIMETER_ZN_4_MISCPLUG_EQUIP BLDG_EQUIP_SCH PERIMETER_ZN_4 67.30 3.6 456.294 6.780 125.977 0.000 0.000 0.000 1.000 MiscPlug 0.000 456.294


Shadowing/Sun Position Calculations Annual Simulations

Shading Calculation Method Shading Calculation Update Frequency Method Shading Calculation Update Frequency {days} Maximum Figures in Shadow Overlap Calculations {} Polygon Clipping Algorithm Pixel Counting Resolution Sky Diffuse Modeling Algorithm Output External Shading Calculation Results Disable Self-Shading Within Shading Zone Groups Disable Self-Shading From Shading Zone Groups to Other Zones
1 PolygonClipping Periodic 30 15000 SutherlandHodgman 512 SimpleSkyDiffuseModeling No No No


Enclosure/Window Adjacency Daylighting Counts

Enclosure Name Number of Exterior Windows Number of Exterior Windows in Adjacent Enclosures
1 PERIMETER_ZN_1 7 0
2 PERIMETER_ZN_2 4 0
3 PERIMETER_ZN_3 6 0
4 PERIMETER_ZN_4 4 0


Enclosure/Window Adjacency Daylighting Matrix

Enclosure Name Number of Adjacent Enclosures with Windows Adjacent Enclosure Names - 1st 100 (max)
1 PERIMETER_ZN_1 0  
2 PERIMETER_ZN_2 0  
3 PERIMETER_ZN_3 0  
4 PERIMETER_ZN_4 0  


Water Heater Information

Type Name Volume {m3} Maximum Capacity {W} Standard Rated Recovery Efficiency Standard Rated Energy Factor
1 WaterHeater:Mixed SWHSYS1 WATER HEATER 0.1514 11722.8 0.983 0.4683


ZoneInfiltration Airflow Stats Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Design Volume Flow Rate {m3/s} Volume Flow Rate/Floor Area {m3/s-m2} Volume Flow Rate/Exterior Surface Area {m3/s-m2} ACH - Air Changes per Hour Equation A - Constant Term Coefficient {} Equation B - Temperature Term Coefficient {1/C} Equation C - Velocity Term Coefficient {s/m} Equation D - Velocity Squared Term Coefficient {s2/m2}
1 PERIMETER_ZN_1_INFILTRATION INFIL_QUARTER_ON_SCH PERIMETER_ZN_1 113.45 6.1 1.203E-002 1.060E-004 1.424E-004 0.125 0.000 0.000 0.224 0.000
2 PERIMETER_ZN_1_DOOR_INFILTRATION INFIL_DOOR_OPENING_SCH PERIMETER_ZN_1 113.45 6.1 0.130 1.144E-003 1.537E-003 1.350 1.000 0.000 0.000 0.000
3 PERIMETER_ZN_2_INFILTRATION INFIL_QUARTER_ON_SCH PERIMETER_ZN_2 67.30 3.6 8.017E-003 1.191E-004 1.424E-004 0.141 0.000 0.000 0.224 0.000
4 PERIMETER_ZN_3_INFILTRATION INFIL_QUARTER_ON_SCH PERIMETER_ZN_3 113.45 6.1 1.203E-002 1.060E-004 1.361E-004 0.125 0.000 0.000 0.224 0.000
5 PERIMETER_ZN_4_INFILTRATION INFIL_QUARTER_ON_SCH PERIMETER_ZN_4 67.30 3.6 8.017E-003 1.191E-004 1.424E-004 0.141 0.000 0.000 0.224 0.000
6 ATTIC_INFILTRATION ALWAYS_ON ATTIC 567.98 0.0 0.200 3.523E-004 3.052E-004 1.000 1.000 0.000 0.000 0.000


AirFlow Model

Simple
1 Simple


RoomAir Model

Zone Name Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined
1 CORE_ZN Mixing/Well-Stirred
2 PERIMETER_ZN_1 Mixing/Well-Stirred
3 PERIMETER_ZN_2 Mixing/Well-Stirred
4 PERIMETER_ZN_3 Mixing/Well-Stirred
5 PERIMETER_ZN_4 Mixing/Well-Stirred
6 ATTIC Mixing/Well-Stirred


AirflowNetwork Model:Control

No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation
1 NoMultizoneOrDistribution


Zone Volume Capacitance Multiplier

Sensible Heat Capacity Multiplier Moisture Capacity Multiplier Carbon Dioxide Capacity Multiplier Generic Contaminant Capacity Multiplier
1 1.000 1.000 1.000 1.000


Load Timesteps in Zone Design Calculation Averaging Window

Value
1 6


Heating Sizing Factor Information

Sizing Factor ID Value
1 Global 1.2000
2 Zone CORE_ZN 1.2000
3 Zone PERIMETER_ZN_1 1.2000
4 Zone PERIMETER_ZN_2 1.2000
5 Zone PERIMETER_ZN_3 1.2000
6 Zone PERIMETER_ZN_4 1.2000


Cooling Sizing Factor Information

Sizing Factor ID Value
1 Global 1.2000
2 Zone CORE_ZN 1.2000
3 Zone PERIMETER_ZN_1 1.2000
4 Zone PERIMETER_ZN_2 1.2000
5 Zone PERIMETER_ZN_3 1.2000
6 Zone PERIMETER_ZN_4 1.2000


Sky Daylight Factors

Sky Type MonthAndDay Daylighting Control Name Enclosure Name Window Name Reference Point Daylight Factor
1 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 PERIMETER_ZN_1_DAYLREFPT1 1.1053E-003
2 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 PERIMETER_ZN_1_DAYLREFPT2 1.2369E-003
3 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 PERIMETER_ZN_1_DAYLREFPT1 1.1852E-003
4 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 PERIMETER_ZN_1_DAYLREFPT2 1.3038E-003
5 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 PERIMETER_ZN_1_DAYLREFPT1 8.1023E-004
6 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 PERIMETER_ZN_1_DAYLREFPT2 9.0776E-004
7 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 PERIMETER_ZN_1_DAYLREFPT1 3.9490E-004
8 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 PERIMETER_ZN_1_DAYLREFPT2 4.4114E-004
9 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 PERIMETER_ZN_1_DAYLREFPT1 7.0337E-003
10 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 PERIMETER_ZN_1_DAYLREFPT2 6.3460E-003
11 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 PERIMETER_ZN_1_DAYLREFPT1 7.0204E-003
12 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 PERIMETER_ZN_1_DAYLREFPT2 6.6598E-003
13 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 PERIMETER_ZN_1_DAYLREFPT1 6.6408E-003
14 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 PERIMETER_ZN_1_DAYLREFPT2 4.5582E-003
15 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 PERIMETER_ZN_1_DAYLREFPT1 3.3709E-003
16 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 PERIMETER_ZN_1_DAYLREFPT2 1.8142E-003
17 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 PERIMETER_ZN_1_DAYLREFPT1 5.9589E-003
18 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 PERIMETER_ZN_1_DAYLREFPT2 5.8784E-003
19 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 PERIMETER_ZN_1_DAYLREFPT1 5.9391E-003
20 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 PERIMETER_ZN_1_DAYLREFPT2 6.1640E-003
21 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 PERIMETER_ZN_1_DAYLREFPT1 5.5439E-003
22 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 PERIMETER_ZN_1_DAYLREFPT2 4.2057E-003
23 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 PERIMETER_ZN_1_DAYLREFPT1 2.8006E-003
24 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 PERIMETER_ZN_1_DAYLREFPT2 1.6773E-003
25 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 PERIMETER_ZN_1_DAYLREFPT1 1.1000E-003
26 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 PERIMETER_ZN_1_DAYLREFPT2 1.2234E-003
27 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 PERIMETER_ZN_1_DAYLREFPT1 1.1808E-003
28 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 PERIMETER_ZN_1_DAYLREFPT2 1.2925E-003
29 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 PERIMETER_ZN_1_DAYLREFPT1 8.0585E-004
30 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 PERIMETER_ZN_1_DAYLREFPT2 8.9645E-004
31 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 PERIMETER_ZN_1_DAYLREFPT1 3.9164E-004
32 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 PERIMETER_ZN_1_DAYLREFPT2 4.3398E-004
33 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 PERIMETER_ZN_1_DAYLREFPT1 1.0519E-003
34 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 PERIMETER_ZN_1_DAYLREFPT2 1.0653E-003
35 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 PERIMETER_ZN_1_DAYLREFPT1 1.1395E-003
36 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 PERIMETER_ZN_1_DAYLREFPT2 1.1510E-003
37 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 PERIMETER_ZN_1_DAYLREFPT1 7.6814E-004
38 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 PERIMETER_ZN_1_DAYLREFPT2 7.7745E-004
39 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 PERIMETER_ZN_1_DAYLREFPT1 3.6914E-004
40 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 PERIMETER_ZN_1_DAYLREFPT2 3.7405E-004
41 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 PERIMETER_ZN_1_DAYLREFPT1 1.0483E-003
42 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 PERIMETER_ZN_1_DAYLREFPT2 1.0510E-003
43 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 PERIMETER_ZN_1_DAYLREFPT1 1.1365E-003
44 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 PERIMETER_ZN_1_DAYLREFPT2 1.1387E-003
45 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 PERIMETER_ZN_1_DAYLREFPT1 7.6570E-004
46 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 PERIMETER_ZN_1_DAYLREFPT2 7.6744E-004
47 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 PERIMETER_ZN_1_DAYLREFPT1 3.6767E-004
48 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 PERIMETER_ZN_1_DAYLREFPT2 3.6863E-004
49 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_DOOR PERIMETER_ZN_1_DAYLREFPT1 1.6671E-003
50 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_DOOR PERIMETER_ZN_1_DAYLREFPT2 1.9984E-003
51 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_DOOR PERIMETER_ZN_1_DAYLREFPT1 1.7546E-003
52 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_DOOR PERIMETER_ZN_1_DAYLREFPT2 2.0759E-003
53 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_DOOR PERIMETER_ZN_1_DAYLREFPT1 1.2479E-003
54 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_DOOR PERIMETER_ZN_1_DAYLREFPT2 1.4673E-003
55 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_DOOR PERIMETER_ZN_1_DAYLREFPT1 6.2630E-004
56 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_DOOR PERIMETER_ZN_1_DAYLREFPT2 7.0214E-004
57 Clear Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_4 PERIMETER_ZN_2_DAYLREFPT1 8.2710E-004
58 Clear Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_4 PERIMETER_ZN_2_DAYLREFPT2 9.2105E-004
59 Clear Turbid Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_4 PERIMETER_ZN_2_DAYLREFPT1 7.5107E-004
60 Clear Turbid Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_4 PERIMETER_ZN_2_DAYLREFPT2 8.2012E-004
61 Intermediate Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_4 PERIMETER_ZN_2_DAYLREFPT1 7.1410E-004
62 Intermediate Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_4 PERIMETER_ZN_2_DAYLREFPT2 7.4623E-004
63 Overcast Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_4 PERIMETER_ZN_2_DAYLREFPT1 6.1908E-004
64 Overcast Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_4 PERIMETER_ZN_2_DAYLREFPT2 6.6168E-004
65 Clear Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_3 PERIMETER_ZN_2_DAYLREFPT1 3.2871E-003
66 Clear Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_3 PERIMETER_ZN_2_DAYLREFPT2 2.5727E-003
67 Clear Turbid Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_3 PERIMETER_ZN_2_DAYLREFPT1 2.6255E-003
68 Clear Turbid Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_3 PERIMETER_ZN_2_DAYLREFPT2 2.1064E-003
69 Intermediate Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_3 PERIMETER_ZN_2_DAYLREFPT1 2.3091E-003
70 Intermediate Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_3 PERIMETER_ZN_2_DAYLREFPT2 1.8455E-003
71 Overcast Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_3 PERIMETER_ZN_2_DAYLREFPT1 3.0319E-003
72 Overcast Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_3 PERIMETER_ZN_2_DAYLREFPT2 1.9280E-003
73 Clear Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_2 PERIMETER_ZN_2_DAYLREFPT1 8.4187E-003
74 Clear Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_2 PERIMETER_ZN_2_DAYLREFPT2 4.0256E-003
75 Clear Turbid Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_2 PERIMETER_ZN_2_DAYLREFPT1 8.6078E-003
76 Clear Turbid Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_2 PERIMETER_ZN_2_DAYLREFPT2 3.7561E-003
77 Intermediate Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_2 PERIMETER_ZN_2_DAYLREFPT1 7.4190E-003
78 Intermediate Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_2 PERIMETER_ZN_2_DAYLREFPT2 3.5772E-003
79 Overcast Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_2 PERIMETER_ZN_2_DAYLREFPT1 3.6144E-003
80 Overcast Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_2 PERIMETER_ZN_2_DAYLREFPT2 2.0693E-003
81 Clear Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_1 PERIMETER_ZN_2_DAYLREFPT1 9.4923E-004
82 Clear Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_1 PERIMETER_ZN_2_DAYLREFPT2 1.1728E-003
83 Clear Turbid Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_1 PERIMETER_ZN_2_DAYLREFPT1 9.0198E-004
84 Clear Turbid Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_1 PERIMETER_ZN_2_DAYLREFPT2 1.1283E-003
85 Intermediate Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_1 PERIMETER_ZN_2_DAYLREFPT1 7.8591E-004
86 Intermediate Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_1 PERIMETER_ZN_2_DAYLREFPT2 9.1942E-004
87 Overcast Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_1 PERIMETER_ZN_2_DAYLREFPT1 6.2223E-004
88 Overcast Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_1 PERIMETER_ZN_2_DAYLREFPT2 6.6881E-004
89 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 PERIMETER_ZN_3_DAYLREFPT1 4.1995E-004
90 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 PERIMETER_ZN_3_DAYLREFPT2 5.0009E-004
91 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 PERIMETER_ZN_3_DAYLREFPT1 3.3819E-004
92 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 PERIMETER_ZN_3_DAYLREFPT2 3.9989E-004
93 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 PERIMETER_ZN_3_DAYLREFPT1 2.8064E-004
94 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 PERIMETER_ZN_3_DAYLREFPT2 3.2058E-004
95 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 PERIMETER_ZN_3_DAYLREFPT1 3.9068E-004
96 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 PERIMETER_ZN_3_DAYLREFPT2 4.3116E-004
97 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 PERIMETER_ZN_3_DAYLREFPT1 2.6147E-003
98 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 PERIMETER_ZN_3_DAYLREFPT2 2.1680E-003
99 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 PERIMETER_ZN_3_DAYLREFPT1 2.0468E-003
100 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 PERIMETER_ZN_3_DAYLREFPT2 1.6468E-003
101 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 PERIMETER_ZN_3_DAYLREFPT1 1.9248E-003
102 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 PERIMETER_ZN_3_DAYLREFPT2 1.1340E-003
103 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 PERIMETER_ZN_3_DAYLREFPT1 2.5564E-003
104 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 PERIMETER_ZN_3_DAYLREFPT2 1.6125E-003
105 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 PERIMETER_ZN_3_DAYLREFPT1 3.5874E-003
106 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 PERIMETER_ZN_3_DAYLREFPT2 2.5286E-003
107 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 PERIMETER_ZN_3_DAYLREFPT1 2.7835E-003
108 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 PERIMETER_ZN_3_DAYLREFPT2 1.9069E-003
109 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 PERIMETER_ZN_3_DAYLREFPT1 2.5790E-003
110 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 PERIMETER_ZN_3_DAYLREFPT2 1.2690E-003
111 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 PERIMETER_ZN_3_DAYLREFPT1 3.7002E-003
112 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 PERIMETER_ZN_3_DAYLREFPT2 1.8862E-003
113 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 PERIMETER_ZN_3_DAYLREFPT1 4.3051E-004
114 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 PERIMETER_ZN_3_DAYLREFPT2 5.2576E-004
115 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 PERIMETER_ZN_3_DAYLREFPT1 3.4644E-004
116 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 PERIMETER_ZN_3_DAYLREFPT2 4.1926E-004
117 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 PERIMETER_ZN_3_DAYLREFPT1 2.8717E-004
118 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 PERIMETER_ZN_3_DAYLREFPT2 3.3249E-004
119 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 PERIMETER_ZN_3_DAYLREFPT1 3.9723E-004
120 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 PERIMETER_ZN_3_DAYLREFPT2 4.4551E-004
121 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 PERIMETER_ZN_3_DAYLREFPT1 3.8248E-004
122 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 PERIMETER_ZN_3_DAYLREFPT2 3.9462E-004
123 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 PERIMETER_ZN_3_DAYLREFPT1 3.0815E-004
124 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 PERIMETER_ZN_3_DAYLREFPT2 3.1767E-004
125 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 PERIMETER_ZN_3_DAYLREFPT1 2.5574E-004
126 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 PERIMETER_ZN_3_DAYLREFPT2 2.6215E-004
127 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 PERIMETER_ZN_3_DAYLREFPT1 3.6983E-004
128 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 PERIMETER_ZN_3_DAYLREFPT2 3.7529E-004
129 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 PERIMETER_ZN_3_DAYLREFPT1 3.7888E-004
130 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 PERIMETER_ZN_3_DAYLREFPT2 3.8135E-004
131 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 PERIMETER_ZN_3_DAYLREFPT1 3.0526E-004
132 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 PERIMETER_ZN_3_DAYLREFPT2 3.0721E-004
133 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 PERIMETER_ZN_3_DAYLREFPT1 2.5355E-004
134 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 PERIMETER_ZN_3_DAYLREFPT2 2.5489E-004
135 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 PERIMETER_ZN_3_DAYLREFPT1 3.6816E-004
136 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 PERIMETER_ZN_3_DAYLREFPT2 3.6920E-004
137 Clear Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_4 PERIMETER_ZN_4_DAYLREFPT1 9.3504E-004
138 Clear Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_4 PERIMETER_ZN_4_DAYLREFPT2 1.1447E-003
139 Clear Turbid Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_4 PERIMETER_ZN_4_DAYLREFPT1 8.8346E-004
140 Clear Turbid Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_4 PERIMETER_ZN_4_DAYLREFPT2 1.0929E-003
141 Intermediate Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_4 PERIMETER_ZN_4_DAYLREFPT1 7.7468E-004
142 Intermediate Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_4 PERIMETER_ZN_4_DAYLREFPT2 9.0367E-004
143 Overcast Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_4 PERIMETER_ZN_4_DAYLREFPT1 6.2325E-004
144 Overcast Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_4 PERIMETER_ZN_4_DAYLREFPT2 6.6949E-004
145 Clear Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_3 PERIMETER_ZN_4_DAYLREFPT1 7.9540E-003
146 Clear Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_3 PERIMETER_ZN_4_DAYLREFPT2 3.8361E-003
147 Clear Turbid Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_3 PERIMETER_ZN_4_DAYLREFPT1 8.0351E-003
148 Clear Turbid Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_3 PERIMETER_ZN_4_DAYLREFPT2 3.5459E-003
149 Intermediate Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_3 PERIMETER_ZN_4_DAYLREFPT1 7.1713E-003
150 Intermediate Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_3 PERIMETER_ZN_4_DAYLREFPT2 3.4360E-003
151 Overcast Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_3 PERIMETER_ZN_4_DAYLREFPT1 3.5992E-003
152 Overcast Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_3 PERIMETER_ZN_4_DAYLREFPT2 2.0426E-003
153 Clear Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_2 PERIMETER_ZN_4_DAYLREFPT1 3.2930E-003
154 Clear Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_2 PERIMETER_ZN_4_DAYLREFPT2 2.5418E-003
155 Clear Turbid Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_2 PERIMETER_ZN_4_DAYLREFPT1 2.6186E-003
156 Clear Turbid Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_2 PERIMETER_ZN_4_DAYLREFPT2 2.0710E-003
157 Intermediate Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_2 PERIMETER_ZN_4_DAYLREFPT1 2.2772E-003
158 Intermediate Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_2 PERIMETER_ZN_4_DAYLREFPT2 1.7936E-003
159 Overcast Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_2 PERIMETER_ZN_4_DAYLREFPT1 3.0289E-003
160 Overcast Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_2 PERIMETER_ZN_4_DAYLREFPT2 1.9056E-003
161 Clear Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_1 PERIMETER_ZN_4_DAYLREFPT1 8.1403E-004
162 Clear Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_1 PERIMETER_ZN_4_DAYLREFPT2 9.0818E-004
163 Clear Turbid Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_1 PERIMETER_ZN_4_DAYLREFPT1 7.3393E-004
164 Clear Turbid Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_1 PERIMETER_ZN_4_DAYLREFPT2 8.0299E-004
165 Intermediate Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_1 PERIMETER_ZN_4_DAYLREFPT1 7.0124E-004
166 Intermediate Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_1 PERIMETER_ZN_4_DAYLREFPT2 7.3278E-004
167 Overcast Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_1 PERIMETER_ZN_4_DAYLREFPT1 6.1999E-004
168 Overcast Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_1 PERIMETER_ZN_4_DAYLREFPT2 6.6233E-004


Zone Sizing Information

Zone Name Load Type Calc Des Load {W} User Des Load {W} Calc Des Air Flow Rate {m3/s} User Des Air Flow Rate {m3/s} Design Day Name Date/Time of Peak Temperature at Peak {C} Humidity Ratio at Peak {kgWater/kgDryAir} Floor Area {m2} # Occupants Calc Outdoor Air Flow Rate {m3/s} Calc DOAS Heat Addition Rate {W}
1 CORE_ZN Cooling 3325.76074 3990.91289 0.28137 0.33764 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 16:10:00 37.14667 6.86994E-003 149.65740 8.05449 6.46220E-002 0.00000
2 CORE_ZN Heating 1026.01943 1231.22332 5.10044E-002 6.46220E-002 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 -5.20000 2.80840E-003 149.65740 8.05449 6.46220E-002 0.00000
3 PERIMETER_ZN_1 Cooling 3828.56799 4594.28159 0.32391 0.38869 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 15:50:00 37.45000 6.87043E-003 113.45000 6.10582 4.89877E-002 0.00000
4 PERIMETER_ZN_1 Heating 2823.82690 3388.59228 0.14037 0.16845 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 -5.20000 2.80840E-003 113.45000 6.10582 4.89877E-002 0.00000
5 PERIMETER_ZN_2 Cooling 2793.41721 3352.10065 0.23632 0.28359 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 34.13500 6.86515E-003 67.30000 3.62205 2.90601E-002 0.00000
6 PERIMETER_ZN_2 Heating 1802.18717 2162.62461 8.95878E-002 0.10751 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 -5.20000 2.80840E-003 67.30000 3.62205 2.90601E-002 0.00000
7 PERIMETER_ZN_3 Cooling 3778.72570 4534.47084 0.31969 0.38363 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 15:50:00 37.45000 6.87043E-003 113.45000 6.10582 4.89877E-002 0.00000
8 PERIMETER_ZN_3 Heating 2800.23241 3360.27889 0.13920 0.16704 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 -5.20000 2.80840E-003 113.45000 6.10582 4.89877E-002 0.00000
9 PERIMETER_ZN_4 Cooling 3377.47608 4052.97129 0.28574 0.34288 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 17:20:00 35.84667 6.86787E-003 67.30000 3.62205 2.90601E-002 0.00000
10 PERIMETER_ZN_4 Heating 1789.01614 2146.81936 8.89330E-002 0.10672 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 -5.20000 2.80840E-003 67.30000 3.62205 2.90601E-002 0.00000


System Sizing Information

System Name Load Type Peak Load Kind User Design Capacity Calc Des Air Flow Rate [m3/s] User Des Air Flow Rate [m3/s] Design Day Name Date/Time of Peak
1 PSZ-AC:1 Cooling Sensible 4828.24 0.33764 0.33764 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
2 PSZ-AC:1 Heating Sensible 3065.23 6.46220E-002 6.46220E-002 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 00:10:00
3 PSZ-AC:2 Cooling Sensible 5220.36 0.38869 0.38869 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
4 PSZ-AC:2 Heating Sensible 4691.77 0.16845 0.16845 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00
5 PSZ-AC:3 Cooling Sensible 3612.71 0.28359 0.28359 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
6 PSZ-AC:3 Heating Sensible 2933.47 0.10751 0.10751 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00
7 PSZ-AC:4 Cooling Sensible 5161.48 0.38363 0.38363 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
8 PSZ-AC:4 Heating Sensible 4663.87 0.16704 0.16704 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00
9 PSZ-AC:5 Cooling Sensible 4354.94 0.34288 0.34288 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 05:00:00
10 PSZ-AC:5 Heating Sensible 2917.89 0.10672 0.10672 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00


Component Sizing Information

Component Type Component Name Input Field Description Value
1 AirTerminal:SingleDuct:ConstantVolume:NoReheat CORE_ZN DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.33764
2 AirTerminal:SingleDuct:ConstantVolume:NoReheat PERIMETER_ZN_1 DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.38869
3 AirTerminal:SingleDuct:ConstantVolume:NoReheat PERIMETER_ZN_2 DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.28359
4 AirTerminal:SingleDuct:ConstantVolume:NoReheat PERIMETER_ZN_3 DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.38363
5 AirTerminal:SingleDuct:ConstantVolume:NoReheat PERIMETER_ZN_4 DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.34288
6 AirLoopHVAC PSZ-AC:1 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.33764
7 AirLoopHVAC PSZ-AC:1 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.33764
8 AirLoopHVAC PSZ-AC:1 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.33764
9 AirLoopHVAC PSZ-AC:1 Adjusted Heating Design Air Flow Rate [m3/s] 0.33764
10 AirLoopHVAC PSZ-AC:1 Adjusted Cooling Design Air Flow Rate [m3/s] 0.33764
11 AirLoopHVAC PSZ-AC:1 Adjusted Main Design Air Flow Rate [m3/s] 0.33764
12 AirLoopHVAC PSZ-AC:1 User Heating Air Flow Ratio [] 1.00000
13 AirLoopHVAC PSZ-AC:1 Calculated Heating Air Flow Ratio [] 1.00000
14 AirLoopHVAC PSZ-AC:2 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.38869
15 AirLoopHVAC PSZ-AC:2 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.38869
16 AirLoopHVAC PSZ-AC:2 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.38869
17 AirLoopHVAC PSZ-AC:2 Adjusted Heating Design Air Flow Rate [m3/s] 0.38869
18 AirLoopHVAC PSZ-AC:2 Adjusted Cooling Design Air Flow Rate [m3/s] 0.38869
19 AirLoopHVAC PSZ-AC:2 Adjusted Main Design Air Flow Rate [m3/s] 0.38869
20 AirLoopHVAC PSZ-AC:2 User Heating Air Flow Ratio [] 1.00000
21 AirLoopHVAC PSZ-AC:2 Calculated Heating Air Flow Ratio [] 1.00000
22 AirLoopHVAC PSZ-AC:3 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.28359
23 AirLoopHVAC PSZ-AC:3 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.28359
24 AirLoopHVAC PSZ-AC:3 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.28359
25 AirLoopHVAC PSZ-AC:3 Adjusted Heating Design Air Flow Rate [m3/s] 0.28359
26 AirLoopHVAC PSZ-AC:3 Adjusted Cooling Design Air Flow Rate [m3/s] 0.28359
27 AirLoopHVAC PSZ-AC:3 Adjusted Main Design Air Flow Rate [m3/s] 0.28359
28 AirLoopHVAC PSZ-AC:3 User Heating Air Flow Ratio [] 1.00000
29 AirLoopHVAC PSZ-AC:3 Calculated Heating Air Flow Ratio [] 1.00000
30 AirLoopHVAC PSZ-AC:4 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.38363
31 AirLoopHVAC PSZ-AC:4 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.38363
32 AirLoopHVAC PSZ-AC:4 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.38363
33 AirLoopHVAC PSZ-AC:4 Adjusted Heating Design Air Flow Rate [m3/s] 0.38363
34 AirLoopHVAC PSZ-AC:4 Adjusted Cooling Design Air Flow Rate [m3/s] 0.38363
35 AirLoopHVAC PSZ-AC:4 Adjusted Main Design Air Flow Rate [m3/s] 0.38363
36 AirLoopHVAC PSZ-AC:4 User Heating Air Flow Ratio [] 1.00000
37 AirLoopHVAC PSZ-AC:4 Calculated Heating Air Flow Ratio [] 1.00000
38 AirLoopHVAC PSZ-AC:5 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.34288
39 AirLoopHVAC PSZ-AC:5 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.34288
40 AirLoopHVAC PSZ-AC:5 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.34288
41 AirLoopHVAC PSZ-AC:5 Adjusted Heating Design Air Flow Rate [m3/s] 0.34288
42 AirLoopHVAC PSZ-AC:5 Adjusted Cooling Design Air Flow Rate [m3/s] 0.34288
43 AirLoopHVAC PSZ-AC:5 Adjusted Main Design Air Flow Rate [m3/s] 0.34288
44 AirLoopHVAC PSZ-AC:5 User Heating Air Flow Ratio [] 1.00000
45 AirLoopHVAC PSZ-AC:5 Calculated Heating Air Flow Ratio [] 1.00000
46 AirLoopHVAC PSZ-AC:1 Design Supply Air Flow Rate [m3/s] 0.33764
47 AirLoopHVAC PSZ-AC:2 Design Supply Air Flow Rate [m3/s] 0.38869
48 AirLoopHVAC PSZ-AC:3 Design Supply Air Flow Rate [m3/s] 0.28359
49 AirLoopHVAC PSZ-AC:4 Design Supply Air Flow Rate [m3/s] 0.38363
50 AirLoopHVAC PSZ-AC:5 Design Supply Air Flow Rate [m3/s] 0.34288
51 Controller:OutdoorAir PSZ-AC:1_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.33764
52 Controller:OutdoorAir PSZ-AC:1_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 6.46220E-002
53 Coil:Cooling:DX:SingleSpeed PSZ-AC:1 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.33764
54 Coil:Cooling:DX:SingleSpeed PSZ-AC:1 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 5828.01486
55 Coil:Cooling:DX:SingleSpeed PSZ-AC:1 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80059
56 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Supply Air Flow Rate [m3/s] 0.33764
57 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Supply Air Flow Rate During Heating Operation [m3/s] 0.33764
58 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Supply Air Flow Rate During Cooling Operation [m3/s] 0.33764
59 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] 0.33764
60 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Nominal Heating Capacity [W] 5828.01486
61 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Nominal Cooling Capacity [W] 5828.01486
62 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Maximum Supply Air Temperature from Supplemental Heater [C] 40.00000
63 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Supplemental Heating Coil Nominal Capacity [W] 3065.22639
64 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
65 Fan:OnOff PSZ-AC:1 FAN Design Size Maximum Flow Rate [m3/s] 0.33764
66 Coil:Heating:DX:SingleSpeed PSZ-AC:1 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.33764
67 Coil:Heating:DX:SingleSpeed PSZ-AC:1 HEATING COIL Design Size Gross Rated Heating Capacity [W] 5828.01486
68 Coil:Heating:Fuel PSZ-AC:1_SUPPHEATCOIL Design Size Nominal Capacity [W] 3065.22639
69 Controller:OutdoorAir PSZ-AC:2_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.38869
70 Controller:OutdoorAir PSZ-AC:2_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 4.89877E-002
71 Coil:Cooling:DX:SingleSpeed PSZ-AC:2 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.38869
72 Coil:Cooling:DX:SingleSpeed PSZ-AC:2 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 6434.13391
73 Coil:Cooling:DX:SingleSpeed PSZ-AC:2 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
74 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Supply Air Flow Rate [m3/s] 0.38869
75 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Supply Air Flow Rate During Heating Operation [m3/s] 0.38869
76 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Supply Air Flow Rate During Cooling Operation [m3/s] 0.38869
77 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] 0.38869
78 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Nominal Heating Capacity [W] 6434.13391
79 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Nominal Cooling Capacity [W] 6434.13391
80 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Maximum Supply Air Temperature from Supplemental Heater [C] 40.00000
81 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Supplemental Heating Coil Nominal Capacity [W] 4691.77101
82 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
83 Fan:OnOff PSZ-AC:2 FAN Design Size Maximum Flow Rate [m3/s] 0.38869
84 Coil:Heating:DX:SingleSpeed PSZ-AC:2 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.38869
85 Coil:Heating:DX:SingleSpeed PSZ-AC:2 HEATING COIL Design Size Gross Rated Heating Capacity [W] 6434.13391
86 Coil:Heating:Fuel PSZ-AC:2_SUPPHEATCOIL Design Size Nominal Capacity [W] 4691.77101
87 Controller:OutdoorAir PSZ-AC:3_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.28359
88 Controller:OutdoorAir PSZ-AC:3_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 2.90601E-002
89 Coil:Cooling:DX:SingleSpeed PSZ-AC:3 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.28359
90 Coil:Cooling:DX:SingleSpeed PSZ-AC:3 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 4694.39117
91 Coil:Cooling:DX:SingleSpeed PSZ-AC:3 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
92 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Supply Air Flow Rate [m3/s] 0.28359
93 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Supply Air Flow Rate During Heating Operation [m3/s] 0.28359
94 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Supply Air Flow Rate During Cooling Operation [m3/s] 0.28359
95 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] 0.28359
96 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Nominal Heating Capacity [W] 4694.39117
97 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Nominal Cooling Capacity [W] 4694.39117
98 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Maximum Supply Air Temperature from Supplemental Heater [C] 40.00000
99 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Supplemental Heating Coil Nominal Capacity [W] 2933.46578
100 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
101 Fan:OnOff PSZ-AC:3 FAN Design Size Maximum Flow Rate [m3/s] 0.28359
102 Coil:Heating:DX:SingleSpeed PSZ-AC:3 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.28359
103 Coil:Heating:DX:SingleSpeed PSZ-AC:3 HEATING COIL Design Size Gross Rated Heating Capacity [W] 4694.39117
104 Coil:Heating:Fuel PSZ-AC:3_SUPPHEATCOIL Design Size Nominal Capacity [W] 2933.46578
105 Controller:OutdoorAir PSZ-AC:4_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.38363
106 Controller:OutdoorAir PSZ-AC:4_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 4.89877E-002
107 Coil:Cooling:DX:SingleSpeed PSZ-AC:4 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.38363
108 Coil:Cooling:DX:SingleSpeed PSZ-AC:4 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 6350.37118
109 Coil:Cooling:DX:SingleSpeed PSZ-AC:4 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
110 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Supply Air Flow Rate [m3/s] 0.38363
111 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Supply Air Flow Rate During Heating Operation [m3/s] 0.38363
112 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Supply Air Flow Rate During Cooling Operation [m3/s] 0.38363
113 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] 0.38363
114 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Nominal Heating Capacity [W] 6350.37118
115 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Nominal Cooling Capacity [W] 6350.37118
116 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Maximum Supply Air Temperature from Supplemental Heater [C] 40.00000
117 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Supplemental Heating Coil Nominal Capacity [W] 4663.87003
118 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
119 Fan:OnOff PSZ-AC:4 FAN Design Size Maximum Flow Rate [m3/s] 0.38363
120 Coil:Heating:DX:SingleSpeed PSZ-AC:4 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.38363
121 Coil:Heating:DX:SingleSpeed PSZ-AC:4 HEATING COIL Design Size Gross Rated Heating Capacity [W] 6350.37118
122 Coil:Heating:Fuel PSZ-AC:4_SUPPHEATCOIL Design Size Nominal Capacity [W] 4663.87003
123 Controller:OutdoorAir PSZ-AC:5_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.34288
124 Controller:OutdoorAir PSZ-AC:5_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 2.90601E-002
125 Coil:Cooling:DX:SingleSpeed PSZ-AC:5 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.34288
126 Coil:Cooling:DX:SingleSpeed PSZ-AC:5 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 5675.93517
127 Coil:Cooling:DX:SingleSpeed PSZ-AC:5 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
128 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Supply Air Flow Rate [m3/s] 0.34288
129 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Supply Air Flow Rate During Heating Operation [m3/s] 0.34288
130 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Supply Air Flow Rate During Cooling Operation [m3/s] 0.34288
131 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] 0.34288
132 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Nominal Heating Capacity [W] 5675.93517
133 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Nominal Cooling Capacity [W] 5675.93517
134 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Maximum Supply Air Temperature from Supplemental Heater [C] 40.00000
135 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Supplemental Heating Coil Nominal Capacity [W] 2917.89075
136 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
137 Fan:OnOff PSZ-AC:5 FAN Design Size Maximum Flow Rate [m3/s] 0.34288
138 Coil:Heating:DX:SingleSpeed PSZ-AC:5 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.34288
139 Coil:Heating:DX:SingleSpeed PSZ-AC:5 HEATING COIL Design Size Gross Rated Heating Capacity [W] 5675.93517
140 Coil:Heating:Fuel PSZ-AC:5_SUPPHEATCOIL Design Size Nominal Capacity [W] 2917.89075
141 PlantLoop SWHSYS1 Maximum Loop Flow Rate [m3/s] 4.04800E-006
142 PlantLoop SWHSYS1 Plant Loop Volume [m3] 4.85760E-004
143 Pump:ConstantSpeed SWHSYS1 PUMP Design Flow Rate [m3/s] 4.04800E-006
144 Pump:ConstantSpeed SWHSYS1 PUMP Design Power Consumption [W] 1.72991E-008


DX Cooling Coil Standard Rating Information

Component Type Component Name Standard Rating (Net) Cooling Capacity {W} Standard Rated Net COP {W/W} EER {Btu/W-h} SEER User {Btu/W-h} SEER Standard {Btu/W-h} IEER {Btu/W-h}
1 Coil:Cooling:DX:SingleSpeed PSZ-AC:1 HP COOLING COIL 5563.3 3.32 11.32 11.84 11.20 11.10
2 Coil:Cooling:DX:SingleSpeed PSZ-AC:2 HP COOLING COIL 6129.5 3.29 11.22 11.74 11.10 10.96
3 Coil:Cooling:DX:SingleSpeed PSZ-AC:3 HP COOLING COIL 4472.1 3.29 11.22 11.74 11.10 10.96
4 Coil:Cooling:DX:SingleSpeed PSZ-AC:4 HP COOLING COIL 6049.7 3.29 11.22 11.74 11.10 10.96
5 Coil:Cooling:DX:SingleSpeed PSZ-AC:5 HP COOLING COIL 5407.2 3.29 11.22 11.74 11.10 10.96


DX Heating Coil Standard Rating Information

Component Type Component Name High Temperature Heating (net) Rating Capacity {W} Low Temperature Heating (net) Rating Capacity {W} HSPF {Btu/W-h} Region Number
1 Coil:Heating:DX:SingleSpeed PSZ-AC:1 HEATING COIL 6096.2 3390.3 7.36 4
2 Coil:Heating:DX:SingleSpeed PSZ-AC:2 HEATING COIL 6742.5 3755.2 7.32 4
3 Coil:Heating:DX:SingleSpeed PSZ-AC:3 HEATING COIL 4919.4 2739.8 7.35 4
4 Coil:Heating:DX:SingleSpeed PSZ-AC:4 HEATING COIL 6654.7 3706.3 7.32 4
5 Coil:Heating:DX:SingleSpeed PSZ-AC:5 HEATING COIL 5948.0 3312.7 7.33 4


Environment

Environment Name Environment Type Start Date End Date Start DayOfWeek Duration {#days} Source:Start DayOfWeek Use Daylight Saving Use Holidays Apply Weekend Holiday Rule Use Rain Values Use Snow Values Sky Temperature Model
1 RUNPERIOD 1 WeatherFileRunPeriod 01/01/2017 12/31/2017 Sunday 365 Use RunPeriod Specified Day No No No Yes Yes Clark and Allen


Environment:Special Days

Special Day Name Special Day Type Source Start Date Duration {#days}
1 NEW YEARS DAY Holiday InputFile 01/01 1Environment:Special Days


Environment:Daylight Saving

Daylight Saving Indicator Source Start Date End Date
1 Yes InputFile 03/12 11/05


Tabular Report

Style Unit Conversion
1 Commaandhtml commaandhtml


Warmup Convergence Information

Zone Name Environment Type/Name Average Warmup Temperature Difference {deltaC} Std Dev Warmup Temperature Difference {deltaC} Max Temperature Pass/Fail Convergence Min Temperature Pass/Fail Convergence Average Warmup Load Difference {W} Std Dev Warmup Load Difference {W} Heating Load Pass/Fail Convergence Cooling Load Pass/Fail Convergence
1 CORE_ZN RunPeriod: RUNPERIOD 1 1.4921403381E-002 9.5294261026E-003 Pass Pass 0.0000000000 0.0000000000 Pass Pass
2 PERIMETER_ZN_1 RunPeriod: RUNPERIOD 1 7.0513880565E-002 6.0058280277E-002 Pass Pass 0.0000000000 0.0000000000 Pass Pass
3 PERIMETER_ZN_2 RunPeriod: RUNPERIOD 1 3.3424771940E-002 3.3671094148E-002 Pass Pass 0.0000000000 0.0000000000 Pass Pass
4 PERIMETER_ZN_3 RunPeriod: RUNPERIOD 1 2.4850130462E-002 1.6696347642E-002 Pass Pass 0.0000000000 0.0000000000 Pass Pass
5 PERIMETER_ZN_4 RunPeriod: RUNPERIOD 1 5.2262694370E-002 4.0014268085E-002 Pass Pass 0.0000000000 0.0000000000 Pass Pass
6 ATTIC RunPeriod: RUNPERIOD 1 0.4867321839 0.5036941289 Pass Pass 0.0000000000 0.0000000000 Pass Pass



Table of Contents

Report: Annual Heat Emissions Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

Heat Emission by Components

Envelope Convection Zone Exfiltration Zone Exhaust Air HVAC Relief Air HVAC Reject Heat Total
Heat Emissions [GJ] 1250.89 33.69 0.00 63.46 119.49 1467.54



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB -5.20 0.00 -5.20 Wetbulb [C] 2.20 20.00
EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 38.10 13.00 18.10 Wetbulb [C] 3.90 280.00


Monthly Precipitation Summary

Monthly Total Precipitation from .epw [mm] Monthly Total Hours of Rain from .epw Monthly Total Precipitation in Site:Precipitation [mm] Monthly Total Roof Irrigation Depth [mm] Monthly Total Rain Collection Volume [m3]
Jan 3.00 6      
Feb 3.00 4      
Mar 0.00 0      
Apr 0.00 0      
May 0.00 0      
Jun 18.00 7      
Jul 27.00 16      
Aug 41.00 15      
Sep 0.00 0      
Oct 23.00 18      
Nov 0.00 0      
Dec 7.00 7      


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Net Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
PERIMETER_ZN_1_WALL_SOUTH NONRES_EXT_WALL_GRD 0.30 0.977 1.144 84.45 63.82 180.00 90.00 S
PERIMETER_ZN_1_FLOOR PERIMETER_ZN_1_FLOOR_FFACTOR 1.00 0.308 0.324 113.45 113.45 135.00 180.00  
PERIMETER_ZN_2_WALL_EAST NONRES_EXT_WALL_GRD 0.30 0.977 1.144 56.30 45.15 90.00 90.00 E
PERIMETER_ZN_2_FLOOR PERIMETER_ZN_2_FLOOR_FFACTOR 1.00 0.346 0.366 67.30 67.30 270.00 180.00  
PERIMETER_ZN_3_WALL_NORTH NONRES_EXT_WALL_GRD 0.30 0.977 1.144 84.45 63.83 0.00 90.00 N
PERIMETER_ZN_3_FLOOR PERIMETER_ZN_3_FLOOR_FFACTOR 1.00 0.308 0.324 113.45 113.45 180.00 180.00  
PERIMETER_ZN_4_WALL_WEST NONRES_EXT_WALL_GRD 0.30 0.977 1.144 56.30 45.15 270.00 90.00 W
PERIMETER_ZN_4_FLOOR PERIMETER_ZN_4_FLOOR_FFACTOR 1.00 0.346 0.366 67.30 67.30 90.00 180.00  
ATTIC_SOFFIT_WEST EXT_SOFFIT_FLOOR 0.30 3.082 7.547 11.44 11.44 270.00 180.00  
ATTIC_SOFFIT_SOUTH EXT_SOFFIT_FLOOR 0.30 3.082 7.547 16.97 16.97 225.00 180.00  
ATTIC_SOFFIT_EAST EXT_SOFFIT_FLOOR 0.30 3.082 7.547 11.44 11.44 45.00 180.00  
ATTIC_SOFFIT_NORTH EXT_SOFFIT_FLOOR 0.30 3.082 7.547 16.97 16.97 315.00 180.00  
ATTIC_ROOF_NORTH ATTICROOFDECK 0.30 2.858 4.706 197.51 197.51 0.00 18.45  
ATTIC_ROOF_WEST ATTICROOFDECK 0.30 2.858 4.706 101.87 101.87 270.00 18.45  
ATTIC_ROOF_EAST ATTICROOFDECK 0.30 2.858 4.706 101.87 101.87 90.00 18.45  
ATTIC_ROOF_SOUTH ATTICROOFDECK 0.30 2.858 4.706 197.51 197.51 180.00 18.45  


Opaque Interior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Net Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
CORE_ZN_WALL_SOUTH INT_WALL 0.30 2.511 6.299 53.95 53.95 180.00 90.00 S
CORE_ZN_WALL_EAST INT_WALL 0.30 2.511 6.299 25.80 25.80 90.00 90.00 E
CORE_ZN_WALL_NORTH INT_WALL 0.30 2.511 6.299 53.95 53.95 0.00 90.00 N
CORE_ZN_WALL_WEST INT_WALL 0.30 2.511 6.299 25.80 25.80 270.00 90.00 W
CORE_ZN_FLOOR CORE_ZN_FLOOR_FFACTOR 1.00 0.006 0.006 149.66 149.66 270.00 180.00  
CORE_ZN_CEILING NONRES_ROOF 0.30 0.151 0.158 149.66 149.66 270.00 0.00  
PERIMETER_ZN_1_WALL_WEST INT_WALL 0.30 2.511 6.299 21.57 21.57 315.00 90.00 N
PERIMETER_ZN_1_WALL_EAST INT_WALL 0.30 2.511 6.299 21.57 21.57 45.00 90.00 E
PERIMETER_ZN_1_WALL_NORTH INT_WALL 0.30 2.511 6.299 53.95 53.95 0.00 90.00 N
PERIMETER_ZN_1_CEILING NONRES_ROOF 0.30 0.151 0.158 113.45 113.45 45.00 0.00  
PERIMETER_ZN_2_WALL_NORTH INT_WALL 0.30 2.511 6.299 21.57 21.57 315.00 90.00 N
PERIMETER_ZN_2_WALL_SOUTH INT_WALL 0.30 2.511 6.299 21.57 21.57 225.00 90.00 W
PERIMETER_ZN_2_WALL_WEST INT_WALL 0.30 2.511 6.299 25.80 25.80 270.00 90.00 W
PERIMETER_ZN_2_CEILING NONRES_ROOF 0.30 0.151 0.158 67.30 67.30 270.00 0.00  
PERIMETER_ZN_3_WALL_SOUTH INT_WALL 0.30 2.511 6.299 53.95 53.95 180.00 90.00 S
PERIMETER_ZN_3_WALL_WEST INT_WALL 0.30 2.511 6.299 21.57 21.57 225.00 90.00 W
PERIMETER_ZN_3_WALL_EAST INT_WALL 0.30 2.511 6.299 21.57 21.57 135.00 90.00 S
PERIMETER_ZN_3_CEILING NONRES_ROOF 0.30 0.151 0.158 113.45 113.45 180.00 0.00  
PERIMETER_ZN_4_WALL_SOUTH INT_WALL 0.30 2.511 6.299 21.57 21.57 135.00 90.00 S
PERIMETER_ZN_4_WALL_NORTH INT_WALL 0.30 2.511 6.299 21.57 21.57 45.00 90.00 E
PERIMETER_ZN_4_WALL_EAST INT_WALL 0.30 2.511 6.299 25.80 25.80 90.00 90.00 E
PERIMETER_ZN_4_CEILING NONRES_ROOF 0.30 0.151 0.158 67.30 67.30 90.00 0.00  
ATTIC_FLOOR_PERIMETER_SOUTH NONRES_ROOF_FLOOR 0.30 0.151 0.158 113.45 113.45 180.00 180.00  
ATTIC_FLOOR_PERIMETER_WEST NONRES_ROOF_FLOOR 0.30 0.151 0.158 67.30 67.30 315.00 180.00  
ATTIC_FLOOR_PERIMETER_EAST NONRES_ROOF_FLOOR 0.30 0.151 0.158 67.30 67.30 135.00 180.00  
ATTIC_FLOOR_CORE NONRES_ROOF_FLOOR 0.30 0.151 0.158 149.66 149.66 270.00 180.00  
ATTIC_FLOOR_PERIMETER_NORTH NONRES_ROOF_FLOOR 0.30 0.151 0.158 113.45 113.45 315.00 180.00  
CORE_ZN_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 299.31   0.00 90.00 N
PERIMETER_ZN_1_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 226.90   0.00 90.00 N
PERIMETER_ZN_2_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 134.60   0.00 90.00 N
PERIMETER_ZN_3_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 226.90   0.00 90.00 N
PERIMETER_ZN_4_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 134.60   0.00 90.00 N


Exterior Fenestration

Construction Frame and Divider Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] NFRC Product Type Assembly U-Factor [W/m2-K] Assembly SHGC Assembly Visible Transmittance Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 WINDOW_U_0.4237_SHGC_SOUTH_0.25   2.79 0.00 0.00 2.79 2.79 2.408 0.251 0.251             No PERIMETER_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 WINDOW_U_0.4237_SHGC_SOUTH_0.25   2.79 0.00 0.00 2.79 2.79 2.408 0.251 0.251             No PERIMETER_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 WINDOW_U_0.4237_SHGC_SOUTH_0.25   2.79 0.00 0.00 2.79 2.79 2.408 0.251 0.251             No PERIMETER_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 WINDOW_U_0.4237_SHGC_SOUTH_0.25   2.79 0.00 0.00 2.79 2.79 2.408 0.251 0.251             No PERIMETER_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 WINDOW_U_0.4237_SHGC_SOUTH_0.25   2.79 0.00 0.00 2.79 2.79 2.408 0.251 0.251             No PERIMETER_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 WINDOW_U_0.4237_SHGC_SOUTH_0.25   2.79 0.00 0.00 2.79 2.79 2.408 0.251 0.251             No PERIMETER_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_ZN_1_WALL_SOUTH_DOOR WINDOW_U_0.4237_SHGC_SOUTH_0.25   3.91 0.00 0.00 3.91 3.91 2.408 0.251 0.251             No PERIMETER_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_ZN_2_WALL_EAST_WINDOW_4 WINDOW_U_0.4237_SHGC_EAST_0.25   2.79 0.00 0.00 2.79 2.79 2.408 0.251 0.251             No PERIMETER_ZN_2_WALL_EAST 90.00 90.00 E
PERIMETER_ZN_2_WALL_EAST_WINDOW_3 WINDOW_U_0.4237_SHGC_EAST_0.25   2.79 0.00 0.00 2.79 2.79 2.408 0.251 0.251             No PERIMETER_ZN_2_WALL_EAST 90.00 90.00 E
PERIMETER_ZN_2_WALL_EAST_WINDOW_2 WINDOW_U_0.4237_SHGC_EAST_0.25   2.79 0.00 0.00 2.79 2.79 2.408 0.251 0.251             No PERIMETER_ZN_2_WALL_EAST 90.00 90.00 E
PERIMETER_ZN_2_WALL_EAST_WINDOW_1 WINDOW_U_0.4237_SHGC_EAST_0.25   2.79 0.00 0.00 2.79 2.79 2.408 0.251 0.251             No PERIMETER_ZN_2_WALL_EAST 90.00 90.00 E
PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 WINDOW_U_0.4237_SHGC_NORTH_0.25   2.79 0.00 0.00 2.79 2.79 2.408 0.251 0.251             No PERIMETER_ZN_3_WALL_NORTH 0.00 90.00 N
PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 WINDOW_U_0.4237_SHGC_NORTH_0.25   2.79 0.00 0.00 2.79 2.79 2.408 0.251 0.251             No PERIMETER_ZN_3_WALL_NORTH 0.00 90.00 N
PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 WINDOW_U_0.4237_SHGC_NORTH_0.25   2.79 0.00 0.00 2.79 2.79 2.408 0.251 0.251             No PERIMETER_ZN_3_WALL_NORTH 0.00 90.00 N
PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 WINDOW_U_0.4237_SHGC_NORTH_0.25   2.79 0.00 0.00 2.79 2.79 2.408 0.251 0.251             No PERIMETER_ZN_3_WALL_NORTH 0.00 90.00 N
PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 WINDOW_U_0.4237_SHGC_NORTH_0.25   2.79 0.00 0.00 2.79 2.79 2.408 0.251 0.251             No PERIMETER_ZN_3_WALL_NORTH 0.00 90.00 N
PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 WINDOW_U_0.4237_SHGC_NORTH_0.25   2.79 0.00 0.00 2.79 2.79 2.408 0.251 0.251             No PERIMETER_ZN_3_WALL_NORTH 0.00 90.00 N
PERIMETER_ZN_4_WALL_WEST_WINDOW_4 WINDOW_U_0.4237_SHGC_WEST_0.25   2.79 0.00 0.00 2.79 2.79 2.408 0.251 0.251             No PERIMETER_ZN_4_WALL_WEST 270.00 90.00 W
PERIMETER_ZN_4_WALL_WEST_WINDOW_3 WINDOW_U_0.4237_SHGC_WEST_0.25   2.79 0.00 0.00 2.79 2.79 2.408 0.251 0.251             No PERIMETER_ZN_4_WALL_WEST 270.00 90.00 W
PERIMETER_ZN_4_WALL_WEST_WINDOW_2 WINDOW_U_0.4237_SHGC_WEST_0.25   2.79 0.00 0.00 2.79 2.79 2.408 0.251 0.251             No PERIMETER_ZN_4_WALL_WEST 270.00 90.00 W
PERIMETER_ZN_4_WALL_WEST_WINDOW_1 WINDOW_U_0.4237_SHGC_WEST_0.25   2.79 0.00 0.00 2.79 2.79 2.408 0.251 0.251             No PERIMETER_ZN_4_WALL_WEST 270.00 90.00 W
Total or Average             59.65 2.408 0.251 0.251                      
North Total or Average             16.72 2.408 0.251 0.251                      
Non-North Total or Average             42.93 2.408 0.251 0.251                      


Exterior Fenestration Shaded State

Frame and Divider Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance NFRC Product Type Assembly U-Factor [W/m2-K] Assembly SHGC Assembly Visible Transmittance
None                


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance
Total or Average     0.00 - - -


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
PERIMETER_ZN_3_WALL_NORTH_DOOR1 SWINGING DOOR_CON 1.598 2.101 1.95 PERIMETER_ZN_3_WALL_NORTH
PERIMETER_ZN_3_WALL_NORTH_DOOR2 SWINGING DOOR_CON 1.598 2.101 1.95 PERIMETER_ZN_3_WALL_NORTH


Interior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 0.84 0.82 0.83 0.00 0.00 0.00 1.00 1.00 1.00
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 0.84 0.82 0.83 0.00 0.00 0.00 1.00 1.00 1.00
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 0.84 0.82 0.83 0.00 0.00 0.00 1.00 1.00 1.00
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 0.84 0.82 0.83 0.00 0.00 0.00 1.00 1.00 1.00
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 0.84 0.82 0.83 0.00 0.00 0.00 1.00 1.00 1.00
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 0.84 0.82 0.83 0.00 0.00 0.00 1.00 1.00 1.00
PERIMETER_ZN_1_WALL_SOUTH_DOOR 1.00 1.00 1.00 0.00 0.00 0.00 1.00 1.00 1.00
PERIMETER_ZN_2_WALL_EAST_WINDOW_4 1.00 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
PERIMETER_ZN_2_WALL_EAST_WINDOW_3 1.00 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
PERIMETER_ZN_2_WALL_EAST_WINDOW_2 1.00 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
PERIMETER_ZN_2_WALL_EAST_WINDOW_1 1.00 0.00 0.00 1.00 0.00 0.00 1.00 0.14 0.00
PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 0.00 0.00 0.00 0.01 0.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_4_WALL_WEST_WINDOW_4 0.00 0.00 0.97 0.00 0.00 0.85 0.00 0.00 1.00
PERIMETER_ZN_4_WALL_WEST_WINDOW_3 0.00 0.00 0.97 0.00 0.00 0.85 0.00 0.00 1.00
PERIMETER_ZN_4_WALL_WEST_WINDOW_2 0.00 0.00 0.97 0.00 0.00 0.85 0.00 0.00 1.00
PERIMETER_ZN_4_WALL_WEST_WINDOW_1 0.00 0.00 0.97 0.00 0.00 0.85 0.00 0.00 1.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

Interior Lighting

Zone Name Space Name Space Type Lighting Power Density [W/m2] Space Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
CORE_ZN_LIGHTS CORE_ZN CORE_ZN GENERAL 6.0938 149.66 911.98 LightsWired LTG_SCH_OFFICE 50.53 168.00 49.65 0.0000 Y 8.50
PERIMETER_ZN_1_LIGHTS PERIMETER_ZN_1 PERIMETER_ZN_1 GENERAL 6.0938 113.45 691.34 LightsWired LTG_SCH_OFFICE 50.53 168.00 41.93 0.0000 Y 5.44
PERIMETER_ZN_2_LIGHTS PERIMETER_ZN_2 PERIMETER_ZN_2 GENERAL 6.0938 67.30 410.11 LightsWired LTG_SCH_OFFICE 50.53 168.00 43.52 0.0000 Y 3.35
PERIMETER_ZN_3_LIGHTS PERIMETER_ZN_3 PERIMETER_ZN_3 GENERAL 6.0938 113.45 691.34 LightsWired LTG_SCH_OFFICE 50.53 168.00 45.25 0.0000 Y 5.87
PERIMETER_ZN_4_LIGHTS PERIMETER_ZN_4 PERIMETER_ZN_4 GENERAL 6.0938 67.30 410.11 LightsWired LTG_SCH_OFFICE 50.53 168.00 43.55 0.0000 Y 3.35
Interior Lighting Total       6.0938 511.16 3114.87               26.52


Daylighting

Zone Control Name Daylighting Method Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
PERIMETER_ZN_1_DAYLREFPT1 PERIMETER_ZN_1 PERIMETER_ZN_1_DAYLCTRL SplitFlux Continuous/Off 0.24 691.34 165.85
PERIMETER_ZN_1_DAYLREFPT2 PERIMETER_ZN_1 PERIMETER_ZN_1_DAYLCTRL SplitFlux Continuous/Off 0.03 691.34 20.88
PERIMETER_ZN_2_DAYLREFPT1 PERIMETER_ZN_2 PERIMETER_ZN_2_DAYLCTRL SplitFlux Continuous/Off 0.24 410.11 98.39
PERIMETER_ZN_2_DAYLREFPT2 PERIMETER_ZN_2 PERIMETER_ZN_2_DAYLCTRL SplitFlux Continuous/Off 0.03 410.11 12.39
PERIMETER_ZN_3_DAYLREFPT1 PERIMETER_ZN_3 PERIMETER_ZN_3_DAYLCTRL SplitFlux Continuous/Off 0.24 691.34 165.85
PERIMETER_ZN_3_DAYLREFPT2 PERIMETER_ZN_3 PERIMETER_ZN_3_DAYLCTRL SplitFlux Continuous/Off 0.03 691.34 20.88
PERIMETER_ZN_4_DAYLREFPT1 PERIMETER_ZN_4 PERIMETER_ZN_4_DAYLCTRL SplitFlux Continuous/Off 0.24 410.11 98.39
PERIMETER_ZN_4_DAYLREFPT2 PERIMETER_ZN_4 PERIMETER_ZN_4_DAYLCTRL SplitFlux Continuous/Off 0.03 410.11 12.39


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
EXTERIOR_LIGHTS_A 66.73 AstronomicalClock -   41.77 41.77 0.52
EXTERIOR_LIGHTS_B 202.25 AstronomicalClock -   83.77 62.77 2.38
EXTERIOR_LIGHTS_C 780.12 AstronomicalClock -   83.77 46.49 6.81
Exterior Lighting Total 1049.10           9.71



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

Central Plant

Type Reference Capacity [W] Reference Efficiency [W/W] Rated Capacity [W] Rated Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
None              


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
PSZ-AC:1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   5828.01 4665.82 1162.19 0.80 4.12    
PSZ-AC:2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   6434.13 5151.52 1282.61 0.80 4.12    
PSZ-AC:3 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   4694.39 3758.59 935.80 0.80 4.12    
PSZ-AC:4 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   6350.37 5084.46 1265.91 0.80 4.12    
PSZ-AC:5 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   5675.94 4544.47 1131.47 0.80 4.12    
Nominal values are gross at rated conditions, i.e., the supply air fan heat and electric power NOT accounted for.

DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER User [Btu/W-h] SEER Standard [Btu/W-h] IEER [Btu/W-h]
PSZ-AC:1 HP COOLING COIL   5563.3 3.32 11.32 11.84 11.20 11.10
PSZ-AC:2 HP COOLING COIL   6129.5 3.29 11.22 11.74 11.10 10.96
PSZ-AC:3 HP COOLING COIL   4472.1 3.29 11.22 11.74 11.10 10.96
PSZ-AC:4 HP COOLING COIL   6049.7 3.29 11.22 11.74 11.10 10.96
PSZ-AC:5 HP COOLING COIL   5407.2 3.29 11.22 11.74 11.10 10.96
ANSI/AHRI ratings account for supply air fan heat and electric power. SEER User is calculated using user-input PLF curve and cooling coefficient of degradation whereas SEER Standard is calculated using AHRI Std 210/240-2008 default PLF curve and cooling coefficient of degradation.

DX Cooling Coil ASHRAE 127 Standard Ratings Report

DX Cooling Coil Type Rated Net Cooling Capacity Test A [W] Rated Electric Power Test A [W] Rated Net Cooling Capacity Test B [W] Rated Electric Power Test B [W] Rated Net Cooling Capacity Test C [W] Rated Electric Power Test C [W] Rated Net Cooling Capacity Test D [W] Rated Electric Power Test D [W]
PSZ-AC:1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
PSZ-AC:2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
PSZ-AC:3 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
PSZ-AC:4 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
PSZ-AC:5 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                


DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
PSZ-AC:1 HEATING COIL Coil:Heating:DX:SingleSpeed 6096.2 3390.3 7.36 4
PSZ-AC:2 HEATING COIL Coil:Heating:DX:SingleSpeed 6742.5 3755.2 7.32 4
PSZ-AC:3 HEATING COIL Coil:Heating:DX:SingleSpeed 4919.4 2739.8 7.35 4
PSZ-AC:4 HEATING COIL Coil:Heating:DX:SingleSpeed 6654.7 3706.3 7.32 4
PSZ-AC:5 HEATING COIL Coil:Heating:DX:SingleSpeed 5948.0 3312.7 7.33 4
ANSI/AHRI ratings account for supply air fan heat and electric power.

Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
PSZ-AC:1 HEATING COIL Coil:Heating:DX:SingleSpeed   5828.01 3.36
PSZ-AC:1_SUPPHEATCOIL Coil:Heating:Fuel   3065.23 0.80
PSZ-AC:2 HEATING COIL Coil:Heating:DX:SingleSpeed   6434.13 3.36
PSZ-AC:2_SUPPHEATCOIL Coil:Heating:Fuel   4691.77 0.80
PSZ-AC:3 HEATING COIL Coil:Heating:DX:SingleSpeed   4694.39 3.36
PSZ-AC:3_SUPPHEATCOIL Coil:Heating:Fuel   2933.47 0.80
PSZ-AC:4 HEATING COIL Coil:Heating:DX:SingleSpeed   6350.37 3.36
PSZ-AC:4_SUPPHEATCOIL Coil:Heating:Fuel   4663.87 0.80
PSZ-AC:5 HEATING COIL Coil:Heating:DX:SingleSpeed   5675.94 3.36
PSZ-AC:5_SUPPHEATCOIL Coil:Heating:Fuel   2917.89 0.80
Nominal values are gross at rated conditions, i.e., the supply air fan heat and electric power NOT accounted for.

Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electricity Rate [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction Fan Energy Index End Use Subcategory Design Day Name for Fan Sizing Peak Date/Time for Fan Sizing Peak
PSZ-AC:1 FAN Fan:OnOff 0.56 622.50 0.34 378.19 1120.11 1.00 1.82 General EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 00:10:00
PSZ-AC:2 FAN Fan:OnOff 0.56 622.50 0.39 435.37 1120.11 1.00 1.73 General EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00
PSZ-AC:3 FAN Fan:OnOff 0.56 622.50 0.28 317.65 1120.11 1.00 1.94 General EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00
PSZ-AC:4 FAN Fan:OnOff 0.56 622.50 0.38 429.70 1120.11 1.00 1.74 General EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00
PSZ-AC:5 FAN Fan:OnOff 0.56 622.50 0.34 384.07 1120.11 1.00 1.81 General EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00


Pumps

Type Control Head [pa] Water Flow [m3/s] Electricity Rate [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W] End Use Subcategory
SWHSYS1 PUMP Pump:ConstantSpeed Intermittent 0.00 0.000004 0.00 0.00 0.30 General


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
SWHSYS1 WATER HEATER WaterHeater:Mixed 0.15 11722.84 1.00 0.98 0.47



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

Zone Sensible Cooling

Calculated Design Load [W] User Design Load [W] User Design Load per Area [W/m2] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak {TIMESTAMP} Thermostat Setpoint Temperature at Peak Load [C] Indoor Temperature at Peak Load [C] Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Outdoor Temperature at Peak Load [C] Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Minimum Outdoor Air Flow Rate [m3/s] Heat Gain Rate from DOAS [W]
CORE_ZN 3325.76 3990.91 26.67 0.281 0.338 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 16:10:00 23.89 23.89 0.00904 37.15 0.00687 0.065 0.00
PERIMETER_ZN_1 3828.57 4594.28 40.50 0.324 0.389 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 15:50:00 23.89 23.89 0.00884 37.45 0.00687 0.049 0.00
PERIMETER_ZN_2 2793.42 3352.10 49.81 0.236 0.284 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 23.89 23.89 0.00878 34.14 0.00687 0.029 0.00
PERIMETER_ZN_3 3778.73 4534.47 39.97 0.320 0.384 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 15:50:00 23.89 23.89 0.00884 37.45 0.00687 0.049 0.00
PERIMETER_ZN_4 3377.48 4052.97 60.22 0.286 0.343 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 17:20:00 23.89 23.89 0.00873 35.85 0.00687 0.029 0.00
The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.

Zone Sensible Heating

Calculated Design Load [W] User Design Load [W] User Design Load per Area [W/m2] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak {TIMESTAMP} Thermostat Setpoint Temperature at Peak Load [C] Indoor Temperature at Peak Load [C] Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Outdoor Temperature at Peak Load [C] Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Minimum Outdoor Air Flow Rate [m3/s] Heat Gain Rate from DOAS [W]
CORE_ZN 1026.02 1231.22 8.23 0.051 0.065 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 21.11 21.11 0.00800 -5.20 0.00281 0.065 0.00
PERIMETER_ZN_1 2823.83 3388.59 29.87 0.140 0.168 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 21.11 21.11 0.00794 -5.20 0.00281 0.049 0.00
PERIMETER_ZN_2 1802.19 2162.62 32.13 0.090 0.108 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 21.11 21.11 0.00794 -5.20 0.00281 0.029 0.00
PERIMETER_ZN_3 2800.23 3360.28 29.62 0.139 0.167 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 21.11 21.11 0.00794 -5.20 0.00281 0.049 0.00
PERIMETER_ZN_4 1789.02 2146.82 31.90 0.089 0.107 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 21.11 21.11 0.00794 -5.20 0.00281 0.029 0.00
The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.

System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s] Adjusted cooling [m3/s] Adjusted heating [m3/s] Adjusted main [m3/s] Calculated Heating Air Flow Ratio [] User Heating Air Flow Ratio []
PSZ-AC:1 0.34 0.34 0.06 0.06 0.3376 0.3376 0.3376 1.0000 1.0000
PSZ-AC:2 0.39 0.39 0.17 0.17 0.3887 0.3887 0.3887 1.0000 1.0000
PSZ-AC:3 0.28 0.28 0.11 0.11 0.2836 0.2836 0.2836 1.0000 1.0000
PSZ-AC:4 0.38 0.38 0.17 0.17 0.3836 0.3836 0.3836 1.0000 1.0000
PSZ-AC:5 0.34 0.34 0.11 0.11 0.3429 0.3429 0.3429 1.0000 1.0000


Plant Loop Coincident Design Fluid Flow Rate Adjustments

Previous Design Volume Flow Rate [m3/s] Algorithm Volume Flow Rate [m3/s] Coincident Design Volume Flow Rate [m3/s] Coincident Size Adjusted Peak Sizing Period Name Peak Day into Period {TIMESTAMP}[day] Peak Hour Of Day {TIMESTAMP}[hr] Peak Step Start Minute {TIMESTAMP}[min]
None                


Coil Sizing Summary

Coil Type HVAC Type HVAC Name Coil Final Gross Total Capacity [W] Coil Final Gross Sensible Capacity [W] Coil Final Reference Air Volume Flow Rate [m3/s] Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] Coil U-value Times Area Value [W/K] Design Day Name at Sensible Ideal Loads Peak Date/Time at Sensible Ideal Loads Peak Design Day Name at Air Flow Ideal Loads Peak Date/Time at Air Flow Ideal Loads Peak Coil Total Capacity at Ideal Loads Peak [W] Coil Sensible Capacity at Ideal Loads Peak [W] Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] Coil Entering Air Drybulb at Ideal Loads Peak [C] Coil Entering Air Wetbulb at Ideal Loads Peak [C] Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Coil Leaving Air Drybulb at Ideal Loads Peak [C] Coil Leaving Air Wetbulb at Ideal Loads Peak [C] Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Outdoor Air Drybulb at Ideal Loads Peak [C] Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Outdoor Air Wetbulb at Ideal Loads Peak [C] Outdoor Air Flow Percentage at Ideal Loads Peak [%] Zone Air Drybulb at Ideal Loads Peak [C] Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Zone Air Relative Humidity at Ideal Loads Peak [%] Zone Sensible Heat Gain at Ideal Loads Peak [W] Zone Latent Heat Gain at Ideal Loads Peak [W] Coil Total Capacity at Rating Conditions [W] Coil Sensible Capacity at Rating Conditions [W]
PSZ-AC:1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC PSZ-AC:1 5828.015 4665.822 0.337639 -999.0 -999.000 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 16:10:00 5218.57 5130.72 0.337639 27.48 16.19 0.00862337 12.80 10.82 0.00850000 37.15 0.00686994 17.88 19.1394 23.89 0.00904269 42.4619 3304.58 0.00 5827.02 4339.21
PSZ-AC:1 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoopHVAC PSZ-AC:1 5828.015 5828.015 0.337639 -999.0 -999.000 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 00:10:00 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 00:10:00 5828.01 5828.01 0.337639 16.07 10.67 0.00700636 40.00 19.53 0.00800000 -5.20 0.00280840 -5.20 19.1394 21.11 0.00800000 44.5505 1025.38 0.00 5835.67 5835.67
PSZ-AC:1_SUPPHEATCOIL Coil:Heating:Fuel AirLoopHVAC PSZ-AC:1 3065.226 3065.226 -999.0 -999.0 -999.000 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 00:10:00 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 00:10:00 3065.23 3065.23 0.337639 16.07 10.67 0.00700636 40.00 19.53 0.00800000 -5.20 0.00280840 -5.20 19.1394 21.11 0.00800000 44.5505 1025.38 0.00 -999.00 -999.00
PSZ-AC:2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC PSZ-AC:2 6434.134 5151.523 0.388686 -999.0 -999.000 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 15:30:00 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 15:50:00 5689.84 5614.90 0.388686 26.65 15.89 0.00859179 12.80 10.82 0.00850000 37.45 0.00687043 17.97 12.6034 23.89 0.00884080 41.5265 3820.32 0.00 6433.03 4790.34
PSZ-AC:2 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoopHVAC PSZ-AC:2 6434.134 6434.134 0.388686 -999.0 -999.000 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 6434.13 6434.13 0.388686 17.79 11.62 0.00729594 40.00 19.53 0.00800000 -5.20 0.00280840 -5.20 12.6034 21.11 0.00794308 44.2379 2823.83 0.00 6442.59 6442.59
PSZ-AC:2_SUPPHEATCOIL Coil:Heating:Fuel AirLoopHVAC PSZ-AC:2 4691.771 4691.771 -999.0 -999.0 -999.000 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 4691.77 4691.77 0.388686 17.79 11.62 0.00729594 40.00 19.53 0.00800000 -5.20 0.00280840 -5.20 12.6034 21.11 0.00794308 44.2379 2823.83 0.00 -999.00 -999.00
PSZ-AC:3 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC PSZ-AC:3 4694.391 3758.589 0.283588 -999.0 -999.000 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 10:50:00 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 4281.41 4230.21 0.283588 25.99 15.67 0.00858009 12.80 10.82 0.00850000 34.14 0.00686515 16.95 10.2473 23.89 0.00877711 41.2312 2784.70 0.00 4693.59 3495.07
PSZ-AC:3 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoopHVAC PSZ-AC:3 4694.391 4694.391 0.283588 -999.0 -999.000 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 4694.39 4694.39 0.283588 18.41 11.97 0.00741466 40.00 19.53 0.00800000 -5.20 0.00280840 -5.20 10.2473 21.11 0.00794057 44.2242 1802.19 0.00 4700.56 4700.56
PSZ-AC:3_SUPPHEATCOIL Coil:Heating:Fuel AirLoopHVAC PSZ-AC:3 2933.466 2933.466 -999.0 -999.0 -999.000 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 2933.47 2933.47 0.283588 18.41 11.97 0.00741466 40.00 19.53 0.00800000 -5.20 0.00280840 -5.20 10.2473 21.11 0.00794057 44.2242 1802.19 0.00 -999.00 -999.00
PSZ-AC:4 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC PSZ-AC:4 6350.371 5084.458 0.383626 -999.0 -999.000 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 15:30:00 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 15:50:00 5617.10 5542.72 0.383626 26.67 15.90 0.00859241 12.80 10.82 0.00850000 37.45 0.00687043 17.97 12.7697 23.89 0.00884518 41.5468 3771.60 0.00 6349.28 4727.98
PSZ-AC:4 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoopHVAC PSZ-AC:4 6350.371 6350.371 0.383626 -999.0 -999.000 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 6350.37 6350.37 0.383626 17.75 11.60 0.00728699 40.00 19.53 0.00800000 -5.20 0.00280840 -5.20 12.7697 21.11 0.00794261 44.2353 2800.23 0.00 6358.72 6358.72
PSZ-AC:4_SUPPHEATCOIL Coil:Heating:Fuel AirLoopHVAC PSZ-AC:4 4663.870 4663.870 -999.0 -999.0 -999.000 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 4663.87 4663.87 0.383626 17.75 11.60 0.00728699 40.00 19.53 0.00800000 -5.20 0.00280840 -5.20 12.7697 21.11 0.00794261 44.2353 2800.23 0.00 -999.00 -999.00
PSZ-AC:5 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC PSZ-AC:5 5675.935 4544.467 0.342883 -999.0 -999.000 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 17:10:00 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 17:20:00 5078.85 5025.45 0.342883 25.95 15.65 0.00857015 12.80 10.82 0.00850000 35.85 0.00686787 17.48 8.4752 23.89 0.00872756 41.0015 3373.03 0.00 5674.96 4225.85
PSZ-AC:5 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoopHVAC PSZ-AC:5 5675.935 5675.935 0.342883 -999.0 -999.000 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 5675.94 5675.94 0.342883 18.88 12.23 0.00750521 40.00 19.53 0.00800000 -5.20 0.00280840 -5.20 8.4752 21.11 0.00794014 44.2218 1789.02 0.00 5683.39 5683.39
PSZ-AC:5_SUPPHEATCOIL Coil:Heating:Fuel AirLoopHVAC PSZ-AC:5 2917.891 2917.891 -999.0 -999.0 -999.000 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 2917.89 2917.89 0.342883 18.88 12.23 0.00750521 40.00 19.53 0.00800000 -5.20 0.00280840 -5.20 8.4752 21.11 0.00794014 44.2218 1789.02 0.00 -999.00 -999.00



Table of Contents

Report: Coil Sizing Details

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

Coils

Coil Type Coil Location HVAC Type HVAC Name Zone Name(s) System Sizing Method Concurrence System Sizing Method Capacity System Sizing Method Air Flow Autosized Coil Capacity? Autosized Coil Airflow? Autosized Coil Water Flow? OA Pretreated prior to coil inlet? Coil Final Gross Total Capacity [W] Coil Final Gross Sensible Capacity [W] Coil Final Reference Air Volume Flow Rate [m3/s] Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] Coil U-value Times Area Value [W/K] Terminal Unit Reheat Coil Multiplier DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio Moist Air Heat Capacity [J/kg-K] Dry Air Heat Capacity [J/kg-K] Standard Air Density Adjusted for Elevation [kg/m3] Supply Fan Name for Coil Supply Fan Type for Coil Supply Fan Maximum Air Volume Flow Rate [m3/s] Supply Fan Maximum Air Mass Flow Rate [kg/s] Plant Name for Coil Plant Fluid Specific Heat Capacity [J/kg-K] Plant Fluid Density [kg/m3] Plant Maximum Fluid Mass Flow Rate [kg/s] Plant Design Fluid Return Temperature [C] Plant Design Fluid Supply Temperature [C] Plant Design Fluid Temperature Difference [deltaC] Plant Design Capacity [W] Coil Capacity Percentage of Plant Design Capacity [%] Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] Design Day Name at Sensible Ideal Loads Peak Date/Time at Sensible Ideal Loads Peak Design Day Name at Total Ideal Loads Peak Date/Time at Total Ideal Loads Peak Design Day Name at Air Flow Ideal Loads Peak Date/Time at Air Flow Ideal Loads Peak Peak Load Type to Size On Coil Total Capacity at Ideal Loads Peak [W] Coil Sensible Capacity at Ideal Loads Peak [W] Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] Coil Entering Air Drybulb at Ideal Loads Peak [C] Coil Entering Air Wetbulb at Ideal Loads Peak [C] Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] Coil Leaving Air Drybulb at Ideal Loads Peak [C] Coil Leaving Air Wetbulb at Ideal Loads Peak [C] Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] Supply Fan Air Heat Gain at Ideal Loads Peak [W] Coil and Fan Net Total Capacity at Ideal Loads Peak [W] Outdoor Air Drybulb at Ideal Loads Peak [C] Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Outdoor Air Wetbulb at Ideal Loads Peak [C] Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] Outdoor Air Flow Percentage at Ideal Loads Peak [%] System Return Air Drybulb at Ideal Loads Peak [C] System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Zone Air Drybulb at Ideal Loads Peak [C] Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Zone Air Relative Humidity at Ideal Loads Peak [%] Zone Sensible Heat Gain at Ideal Loads Peak [W] Zone Latent Heat Gain at Ideal Loads Peak [W] Coil Total Capacity at Rating Conditions [W] Coil Sensible Capacity at Rating Conditions [W] Coil Air Mass Flow Rate at Rating Conditions [kg/s] Coil Entering Air Drybulb at Rating Conditions [C] Coil Entering Air Wetbulb at Rating Conditions [C] Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] Coil Leaving Air Drybulb at Rating Conditions [C] Coil Leaving Air Wetbulb at Rating Conditions [C] Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K]
PSZ-AC:1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:1 CORE_ZN Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 5828.015 4665.822 0.337639 -999.0 -999.000 -999.0000 1.00000 1.00000 1020.8704 1004.8586 1.0443 PSZ-AC:1 FAN Fan:OnOff 0.337639 0.35260711   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 15:00:00 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 16:10:00 Sensible 5218.57 5130.72 0.8954 0.35260711 0.337639 27.48 16.19 0.00862337 49617.4 12.80 10.82 0.00850000 34322.2 -999.0 -999.00 -999.00 -999.00 378.192 4840.38 37.15 0.00686994 17.88 0.06462205 19.1394 23.89 0.00903839 23.89 0.00904269 42.4619 3304.58 0.00 5827.02 4339.21 0.33868180 26.67 19.44 0.01118466 55322.4 14.14 13.58 0.00946229 38117.4
PSZ-AC:1 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:1 CORE_ZN Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 5828.015 5828.015 0.337639 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0443 PSZ-AC:1 FAN Fan:OnOff 0.337639 0.35260711   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 00:10:00 unknown unknown EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 00:10:00 Sensible 5828.01 5828.01 1.0000 0.35260711 0.337639 16.07 10.67 0.00700636 33884.1 40.00 19.53 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 5828.01 -5.20 0.00280840 -5.20 0.06462205 19.1394 21.11 0.00800000 21.11 0.00800000 44.5505 1025.38 0.00 5835.67 5835.67 0.34637643 21.11 15.56 0.00875166 43444.1 37.61 21.02 0.00875166 60291.9
PSZ-AC:1_SUPPHEATCOIL Coil:Heating:Fuel AirLoop AirLoopHVAC PSZ-AC:1 CORE_ZN Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 3065.226 3065.226 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0443 PSZ-AC:1 FAN Fan:OnOff 0.337639 0.35260711   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 00:10:00 unknown unknown EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 00:10:00 Sensible 3065.23 3065.23 1.0000 0.35260711 0.337639 16.07 10.67 0.00700636 33884.1 40.00 19.53 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 3065.23 -5.20 0.00280840 -5.20 0.06462205 19.1394 21.11 0.00800000 21.11 0.00800000 44.5505 1025.38 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
PSZ-AC:2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:2 PERIMETER_ZN_1 Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 6434.134 5151.523 0.388686 -999.0 -999.000 -999.0000 1.00537 1.00000 1020.8117 1004.8586 1.0443 PSZ-AC:2 FAN Fan:OnOff 0.388686 0.40591715   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 15:30:00 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 15:30:00 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 15:50:00 Sensible 5689.84 5614.90 0.8843 0.40591715 0.388686 26.65 15.89 0.00859179 48691.3 12.80 10.82 0.00850000 34322.2 -999.0 -999.00 -999.00 -999.00 435.370 5254.47 37.45 0.00687043 17.97 0.04898769 12.6034 23.89 0.00884002 23.89 0.00884080 41.5265 3820.32 0.00 6433.03 4790.34 0.38988650 26.67 19.44 0.01118466 55322.4 14.65 13.84 0.00953274 38822.6
PSZ-AC:2 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:2 PERIMETER_ZN_1 Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 6434.134 6434.134 0.388686 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0443 PSZ-AC:2 FAN Fan:OnOff 0.388686 0.40591715   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 unknown unknown EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 Sensible 6434.13 6434.13 1.0000 0.40591715 0.388686 17.79 11.62 0.00729594 36368.1 40.00 19.53 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 6434.13 -5.20 0.00280840 -5.20 0.04898769 12.6034 21.11 0.00794308 21.11 0.00794308 44.2379 2823.83 0.00 6442.59 6442.59 0.39874447 21.11 15.56 0.00875166 43444.1 36.93 20.81 0.00875166 59601.3
PSZ-AC:2_SUPPHEATCOIL Coil:Heating:Fuel AirLoop AirLoopHVAC PSZ-AC:2 PERIMETER_ZN_1 Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 4691.771 4691.771 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0443 PSZ-AC:2 FAN Fan:OnOff 0.388686 0.40591715   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 unknown unknown EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 Sensible 4691.77 4691.77 1.0000 0.40591715 0.388686 17.79 11.62 0.00729594 36368.1 40.00 19.53 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 4691.77 -5.20 0.00280840 -5.20 0.04898769 12.6034 21.11 0.00794308 21.11 0.00794308 44.2379 2823.83 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
PSZ-AC:3 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:3 PERIMETER_ZN_2 Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 4694.391 3758.589 0.283588 -999.0 -999.000 -999.0000 1.08780 1.00000 1020.7900 1004.8586 1.0443 PSZ-AC:3 FAN Fan:OnOff 0.283588 0.29616013   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 10:50:00 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 10:50:00 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 10:30:00 Sensible 4281.41 4230.21 0.9120 0.29616013 0.283588 25.99 15.67 0.00858009 47988.9 12.80 10.82 0.00850000 34322.2 -999.0 -999.00 -999.00 -999.00 317.649 3963.76 34.14 0.00686515 16.95 0.02906013 10.2473 23.89 0.00877589 23.89 0.00877711 41.2312 2784.70 0.00 4693.59 3495.07 0.28446404 26.67 19.44 0.01118466 55322.4 14.65 13.84 0.00953274 38822.6
PSZ-AC:3 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:3 PERIMETER_ZN_2 Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 4694.391 4694.391 0.283588 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0443 PSZ-AC:3 FAN Fan:OnOff 0.283588 0.29616013   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 unknown unknown EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 Sensible 4694.39 4694.39 1.0000 0.29616013 0.283588 18.41 11.97 0.00741466 37300.4 40.00 19.53 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 4694.39 -5.20 0.00280840 -5.20 0.02906013 10.2473 21.11 0.00794057 21.11 0.00794057 44.2242 1802.19 0.00 4700.56 4700.56 0.29092688 21.11 15.56 0.00875166 43444.1 36.93 20.81 0.00875166 59601.3
PSZ-AC:3_SUPPHEATCOIL Coil:Heating:Fuel AirLoop AirLoopHVAC PSZ-AC:3 PERIMETER_ZN_2 Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 2933.466 2933.466 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0443 PSZ-AC:3 FAN Fan:OnOff 0.283588 0.29616013   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 unknown unknown EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 Sensible 2933.47 2933.47 1.0000 0.29616013 0.283588 18.41 11.97 0.00741466 37300.4 40.00 19.53 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 2933.47 -5.20 0.00280840 -5.20 0.02906013 10.2473 21.11 0.00794057 21.11 0.00794057 44.2242 1802.19 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
PSZ-AC:4 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:4 PERIMETER_ZN_3 Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 6350.371 5084.458 0.383626 -999.0 -999.000 -999.0000 1.00396 1.00000 1020.8129 1004.8586 1.0443 PSZ-AC:4 FAN Fan:OnOff 0.383626 0.40063272   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 15:30:00 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 15:30:00 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 15:50:00 Sensible 5617.10 5542.72 0.8845 0.40063272 0.383626 26.67 15.90 0.00859241 48715.9 12.80 10.82 0.00850000 34322.2 -999.0 -999.00 -999.00 -999.00 429.702 5187.40 37.45 0.00687043 17.97 0.04898769 12.7697 23.89 0.00884448 23.89 0.00884518 41.5468 3771.60 0.00 6349.28 4727.98 0.38481076 26.67 19.44 0.01118466 55322.4 14.65 13.84 0.00953274 38822.6
PSZ-AC:4 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:4 PERIMETER_ZN_3 Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 6350.371 6350.371 0.383626 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0443 PSZ-AC:4 FAN Fan:OnOff 0.383626 0.40063272   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 unknown unknown EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 Sensible 6350.37 6350.37 1.0000 0.40063272 0.383626 17.75 11.60 0.00728699 36300.9 40.00 19.53 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 6350.37 -5.20 0.00280840 -5.20 0.04898769 12.7697 21.11 0.00794261 21.11 0.00794261 44.2353 2800.23 0.00 6358.72 6358.72 0.39355342 21.11 15.56 0.00875166 43444.1 36.93 20.81 0.00875166 59601.3
PSZ-AC:4_SUPPHEATCOIL Coil:Heating:Fuel AirLoop AirLoopHVAC PSZ-AC:4 PERIMETER_ZN_3 Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 4663.870 4663.870 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0443 PSZ-AC:4 FAN Fan:OnOff 0.383626 0.40063272   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 unknown unknown EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 Sensible 4663.87 4663.87 1.0000 0.40063272 0.383626 17.75 11.60 0.00728699 36300.9 40.00 19.53 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 4663.87 -5.20 0.00280840 -5.20 0.04898769 12.7697 21.11 0.00794261 21.11 0.00794261 44.2353 2800.23 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
PSZ-AC:5 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:5 PERIMETER_ZN_4 Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 5675.935 4544.467 0.342883 -999.0 -999.000 -999.0000 1.07202 1.00000 1020.7715 1004.8586 1.0443 PSZ-AC:5 FAN Fan:OnOff 0.342883 0.35808385   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 17:10:00 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 17:10:00 EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB 7/21 17:20:00 Sensible 5078.85 5025.45 0.8948 0.35808385 0.342883 25.95 15.65 0.00857015 47926.2 12.80 10.82 0.00850000 34322.2 -999.0 -999.00 -999.00 -999.00 384.066 4694.78 35.85 0.00686787 17.48 0.02906013 8.4752 23.89 0.00872778 23.89 0.00872756 41.0015 3373.03 0.00 5674.96 4225.85 0.34394225 26.67 19.44 0.01118466 55322.4 14.65 13.84 0.00953274 38822.6
PSZ-AC:5 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:5 PERIMETER_ZN_4 Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 5675.935 5675.935 0.342883 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0443 PSZ-AC:5 FAN Fan:OnOff 0.342883 0.35808385   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 unknown unknown EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 Sensible 5675.94 5675.94 1.0000 0.35808385 0.342883 18.88 12.23 0.00750521 38004.9 40.00 19.53 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 5675.94 -5.20 0.00280840 -5.20 0.02906013 8.4752 21.11 0.00794014 21.11 0.00794014 44.2218 1789.02 0.00 5683.39 5683.39 0.35175640 21.11 15.56 0.00875166 43444.1 36.93 20.81 0.00875166 59601.3
PSZ-AC:5_SUPPHEATCOIL Coil:Heating:Fuel AirLoop AirLoopHVAC PSZ-AC:5 PERIMETER_ZN_4 Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 2917.891 2917.891 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.0443 PSZ-AC:5 FAN Fan:OnOff 0.342883 0.35808385   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 unknown unknown EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB 12/21 24:00:00 Sensible 2917.89 2917.89 1.0000 0.35808385 0.342883 18.88 12.23 0.00750521 38004.9 40.00 19.53 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 2917.89 -5.20 0.00280840 -5.20 0.02906013 8.4752 21.11 0.00794014 21.11 0.00794014 44.2218 1789.02 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Outdoor Air Per Zone [m3/s] Outdoor Air ACH [ach] Outdoor Air Method Outdoor Air Schedule Name Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule Name
None                    


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
CORE_ZN 2238.67 1997.83 362.00
PERIMETER_ZN_1 2248.83 2239.50 640.50
PERIMETER_ZN_2 2130.50 1919.00 829.83
PERIMETER_ZN_3 2632.33 2405.50 1144.83
PERIMETER_ZN_4 2560.67 2444.17 1087.50
ATTIC 0.00 0.00 0.00
Facility 3186.67 2785.50 1510.83
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
CORE_ZN 0.00 109.33 0.00 109.33
PERIMETER_ZN_1 0.00 30.67 0.00 29.17
PERIMETER_ZN_2 0.00 10.67 0.00 5.83
PERIMETER_ZN_3 0.00 2.67 0.00 2.67
PERIMETER_ZN_4 0.00 19.50 0.00 0.00
ATTIC 0.00 0.00 0.00 0.00
Facility 0.00 147.00 0.00 122.83
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
CORE_ZN 4.75 8.05 456.46 0.397 0.000 0.000 0.000
PERIMETER_ZN_1 3.60 6.11 346.02 0.396 0.370 0.000 0.000
PERIMETER_ZN_2 1.93 3.62 205.26 0.370 0.016 0.000 0.000
PERIMETER_ZN_3 3.60 6.11 346.02 0.395 0.013 0.000 0.000
PERIMETER_ZN_4 2.13 3.62 205.26 0.396 0.014 0.000 0.000
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
CORE_ZN 4.75 8.05 456.46 0.000 0.000 0.000 0.000
PERIMETER_ZN_1 3.60 6.11 346.02 0.000 0.000 0.000 0.000
PERIMETER_ZN_2 1.93 3.62 205.26 0.000 0.000 0.000 0.000
PERIMETER_ZN_3 3.60 6.11 346.02 0.000 0.000 0.000 0.000
PERIMETER_ZN_4 2.13 3.62 205.26 0.000 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Outdoor Air Details

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

Mechanical Ventilation Parameters by Zone

AirLoop Name Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Zone Area [m2] Design Zone Outdoor Airflow - Voz [m3/s] Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s]
CORE_ZN PSZ-AC:1 4.75 8.05 456.46 149.66 0.0646 0.046
PERIMETER_ZN_1 PSZ-AC:2 3.60 6.11 346.02 113.45 0.0490 0.035
PERIMETER_ZN_2 PSZ-AC:3 1.93 3.62 205.26 67.30 0.0291 0.021
PERIMETER_ZN_3 PSZ-AC:4 3.60 6.11 346.02 113.45 0.0490 0.035
PERIMETER_ZN_4 PSZ-AC:5 2.13 3.62 205.26 67.30 0.0291 0.021
Total Facility   16.00 27.51 1559.03 511.16 0.2207 0.156


Total Outdoor Air by Zone

Mechanical Ventilation [m3] Natural Ventilation [m3] Total Ventilation [m3] Infiltration [m3] Total Ventilation and Infiltration [m3] Dynamic Target Ventilation - Voz-dyn [m3] Time Below Voz-dyn [hr] Time At Voz-dyn [hr] Time Above Voz-dyn [hr] Time Above Zero When Unoccupied [hr]
CORE_ZN 762126.55 0.00 762126.55 0.00 762126.55 1606483.19 5484.00 2016.00 1260.00 0.00
PERIMETER_ZN_1 578610.85 0.00 578610.85 572318.19 1150929.04 1217818.28 5483.56 2016.04 1260.40 30.23
PERIMETER_ZN_2 343713.38 0.00 343713.38 33736.86 377450.24 702184.69 5483.40 1512.00 1764.60 827.42
PERIMETER_ZN_3 577854.20 0.00 577854.20 50605.29 628459.48 1217818.28 5483.97 2016.03 1260.00 5.14
PERIMETER_ZN_4 344556.51 0.00 344556.51 33736.86 378293.37 722425.48 5481.70 2016.13 1262.17 106.82
Total Facility 2606861.49 0.00 2606861.49 690397.19 3297258.68 5466729.92 5484.00 2016.20 1767.13 927.02


Average Outdoor Air During Occupancy by Zone - Flow Rates

Mechanical Ventilation [m3/s] Natural Ventilation [m3/s] Total Ventilation [m3/s] Infiltration [m3/s] Total Ventilation and Infiltration [m3/s] Dynamic Target Ventilation - Voz-dyn [m3/s] Time Below Voz-dyn [hr] Time At Voz-dyn [hr] Time Above Voz-dyn [hr]
CORE_ZN 0.0494 0.0000 0.0494 0.0000 0.0494 0.0565 1008.00 2016.00 1260.00
PERIMETER_ZN_1 0.0375 0.0000 0.0375 0.0350 0.0725 0.0428 1008.00 2016.00 1260.00
PERIMETER_ZN_2 0.0208 0.0000 0.0208 0.0009 0.0216 0.0249 1008.00 1512.00 1008.00
PERIMETER_ZN_3 0.0375 0.0000 0.0375 0.0012 0.0387 0.0428 1008.00 2016.00 1260.00
PERIMETER_ZN_4 0.0222 0.0000 0.0222 0.0008 0.0230 0.0254 1008.00 2016.00 1260.00
Total Facility 0.1673 0.0000 0.1673 0.0380 0.2053 0.1925 1008.00 2016.00 1764.00


Total Outdoor Air by AirLoop

Mechanical Ventilation [m3] Natural Ventilation [m3/s] Total Ventilation [m3/s] Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] Time Below Voz-sum-dyn [hr] Time At Voz-sum-dyn [hr] Time Above Voz-sum-dyn [hr] Time Above Zero When Unoccupied [hr]
PSZ-AC:1 831197.14 0.00 831197.14 1606483.19 5484.00 0.00 3276.00 0.00
PSZ-AC:2 631049.64 0.00 631049.64 1217818.28 5483.45 0.04 3276.51 29.65
PSZ-AC:3 374863.70 0.00 374863.70 702184.69 5483.19 0.04 3276.77 824.24
PSZ-AC:4 630224.41 0.00 630224.41 1217818.28 5483.97 0.00 3276.03 5.01
PSZ-AC:5 375783.24 0.00 375783.24 722425.48 5481.07 0.14 3278.78 101.59


Average Outdoor Air During Occupancy by AirLoop

Mechanical Ventilation [m3/s] Natural Ventilation [m3/s] Total Ventilation [m3/s] Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] Time Below Voz-sum-dyn [hr] Time At Voz-sum-dyn [hr] Time Above Voz-sum-dyn [hr]
PSZ-AC:1 0.0539 0.0000 0.0539 0.0565 1008.00 0.00 3276.00
PSZ-AC:2 0.0409 0.0000 0.0409 0.0428 1008.00 0.00 3276.00
PSZ-AC:3 0.0226 0.0000 0.0226 0.0249 1008.00 0.00 2520.00
PSZ-AC:4 0.0409 0.0000 0.0409 0.0428 1008.00 0.00 3276.00
PSZ-AC:5 0.0242 0.0000 0.0242 0.0254 1008.00 0.00 3276.00


Outdoor Air Controller Limiting Factors by AirLoop

No Limiting Factor [hr] Limits and Scheduled Limits [hr] Economizer [hr] Exhaust Flow [hr] Mixed Air Flow [hr] High Humidity [hr] Demand Controlled Ventilation [hr] Night Ventilation [hr] Demand Limiting [hr] Energy Management System [hr]
PSZ-AC:1 0.00 3276.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PSZ-AC:2 0.00 3305.65 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PSZ-AC:3 0.00 3344.24 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PSZ-AC:4 0.00 3281.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PSZ-AC:5 0.00 3383.37 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Average Outdoor Air for Limiting Factors During Occupancy

No Limiting Factor [m3/s] Limits and Scheduled Limits [m3/s] Economizer [m3/s] Exhaust Flow [m3/s] Mixed Air Flow [m3/s] High Humidity [m3/s] Demand Controlled Ventilation [m3/s] Night Ventilation [m3/s] Demand Limiting [m3/s] Energy Management System [m3/s]
PSZ-AC:1 0.0000 0.0705 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
PSZ-AC:2 0.0000 0.0534 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
PSZ-AC:3 0.0000 0.0317 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
PSZ-AC:4 0.0000 0.0534 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
PSZ-AC:5 0.0000 0.0317 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000



Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

Surfaces by Class

Total Outdoors
Wall 20 4
Floor 14 8
Roof 9 4
Internal Mass 5 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 21 21
Door 2 2
Glass Door 1 1
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 5
Conditioned Zones 5
Unconditioned Zones 1
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 524
Defaulted Fields 360
Fields with Defaults 1333
Autosized Fields 115
Autosizable Fields 137
Autocalculated Fields 90
Autocalculatable Fields 156



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Electricity Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
Electricity:Facility 155.77 1473.71 08-JUL-10:00 16700.61 07-AUG-15:40
Electricity:Building 74.81 901.53 30-JUL-09:30 5350.97 22-NOV-17:00
Electricity:Zone:CORE_ZN 22.64 284.81 01-JAN-00:10 1566.66 02-JAN-08:10
Electricity:SpaceType:GENERAL 74.81 901.53 30-JUL-09:30 5350.97 22-NOV-17:00
InteriorLights:Electricity 26.52 333.89 30-JUL-09:30 2025.66 22-NOV-17:00
InteriorLights:Electricity:Zone:CORE_ZN 8.50 118.61 01-JAN-00:10 593.08 02-JAN-08:10
InteriorLights:Electricity:SpaceType:GENERAL 26.52 333.89 30-JUL-09:30 2025.66 22-NOV-17:00
LightsWired:InteriorLights:Electricity 26.52 333.89 30-JUL-09:30 2025.66 22-NOV-17:00
LightsWired:InteriorLights:Electricity:Zone:CORE_ZN 8.50 118.61 01-JAN-00:10 593.08 02-JAN-08:10
LightsWired:InteriorLights:Electricity:SpaceType:GENERAL 26.52 333.89 30-JUL-09:30 2025.66 22-NOV-17:00
Electricity:Zone:PERIMETER_ZN_1 16.16 191.62 01-JAN-08:40 1187.63 22-NOV-17:00
InteriorLights:Electricity:Zone:PERIMETER_ZN_1 5.44 65.63 01-JAN-08:40 449.59 22-NOV-17:00
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_ZN_1 5.44 65.63 01-JAN-08:40 449.59 22-NOV-17:00
Electricity:Zone:PERIMETER_ZN_2 9.71 113.67 01-JAN-08:40 704.52 22-NOV-17:00
InteriorLights:Electricity:Zone:PERIMETER_ZN_2 3.35 38.93 01-JAN-08:40 266.70 22-NOV-17:00
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_ZN_2 3.35 38.93 01-JAN-08:40 266.70 22-NOV-17:00
Electricity:Zone:PERIMETER_ZN_3 16.59 192.51 22-JUL-16:30 1187.63 22-NOV-17:00
InteriorLights:Electricity:Zone:PERIMETER_ZN_3 5.87 66.53 22-JUL-16:30 449.59 22-NOV-17:00
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_ZN_3 5.87 66.53 22-JUL-16:30 449.59 22-NOV-17:00
Electricity:Zone:PERIMETER_ZN_4 9.71 113.67 01-JAN-14:10 704.52 22-NOV-17:00
InteriorLights:Electricity:Zone:PERIMETER_ZN_4 3.35 38.93 01-JAN-14:10 266.70 22-NOV-17:00
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_ZN_4 3.35 38.93 01-JAN-14:10 266.70 22-NOV-17:00
InteriorEquipment:Electricity 48.30 567.64 01-JAN-00:10 3325.31 02-JAN-08:10
InteriorEquipment:Electricity:Zone:CORE_ZN 14.14 166.20 01-JAN-00:10 973.59 02-JAN-08:10
InteriorEquipment:Electricity:SpaceType:GENERAL 48.30 567.64 01-JAN-00:10 3325.31 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity 48.30 567.64 01-JAN-00:10 3325.31 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_ZN 14.14 166.20 01-JAN-00:10 973.59 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL 48.30 567.64 01-JAN-00:10 3325.31 02-JAN-08:10
InteriorEquipment:Electricity:Zone:PERIMETER_ZN_1 10.72 125.99 01-JAN-00:10 738.04 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_ZN_1 10.72 125.99 01-JAN-00:10 738.04 02-JAN-08:10
InteriorEquipment:Electricity:Zone:PERIMETER_ZN_2 6.36 74.74 01-JAN-00:10 437.82 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_ZN_2 6.36 74.74 01-JAN-00:10 437.82 02-JAN-08:10
InteriorEquipment:Electricity:Zone:PERIMETER_ZN_3 10.72 125.99 01-JAN-00:10 738.04 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_ZN_3 10.72 125.99 01-JAN-00:10 738.04 02-JAN-08:10
InteriorEquipment:Electricity:Zone:PERIMETER_ZN_4 6.36 74.74 01-JAN-00:10 437.82 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_ZN_4 6.36 74.74 01-JAN-00:10 437.82 02-JAN-08:10
ElectricityPurchased:Facility 155.77 1473.71 08-JUL-10:00 16700.61 07-AUG-15:40
ElectricityPurchased:Plant 155.77 1473.71 08-JUL-10:00 16700.61 07-AUG-15:40
Cogeneration:ElectricityPurchased 155.77 1473.71 08-JUL-10:00 16700.61 07-AUG-15:40
General:Cogeneration:ElectricityPurchased 155.77 1473.71 08-JUL-10:00 16700.61 07-AUG-15:40
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
ElectricityNet:Facility 155.77 1473.71 08-JUL-10:00 16700.61 07-AUG-15:40
ElectricityNet:Plant 155.77 1473.71 08-JUL-10:00 16700.61 07-AUG-15:40
Cogeneration:ElectricityNet 155.77 1473.71 08-JUL-10:00 16700.61 07-AUG-15:40
General:Cogeneration:ElectricityNet 155.77 1473.71 08-JUL-10:00 16700.61 07-AUG-15:40
ExteriorLights:Electricity 9.71 0.00 01-JAN-07:20 1049.10 01-JAN-06:10
General:ExteriorLights:Electricity 9.71 0.00 01-JAN-07:20 1049.10 01-JAN-06:10
Electricity:HVAC 47.81 0.00 01-JAN-00:10 9084.23 27-DEC-07:30
Fans:Electricity 22.99 0.00 01-JAN-00:10 1944.98 02-JAN-08:30
General:Fans:Electricity 22.99 0.00 01-JAN-00:10 1944.98 02-JAN-08:30
Cooling:Electricity 22.80 0.00 01-JAN-00:10 7046.34 07-AUG-16:00
General:Cooling:Electricity 22.80 0.00 01-JAN-00:10 7046.34 07-AUG-16:00
Heating:Electricity 2.03 0.00 01-JAN-00:10 7139.25 27-DEC-07:30
General:Heating:Electricity 2.03 0.00 01-JAN-00:10 7139.25 27-DEC-07:30
Electricity:Plant 23.43 572.00 02-FEB-08:50 2797.01 30-JAN-12:40
WaterSystems:Electricity 23.43 572.00 09-JAN-09:40 2797.01 30-JAN-12:40
Water Heater:WaterSystems:Electricity 23.43 572.00 09-JAN-09:40 2797.01 30-JAN-12:40
Pumps:Electricity 0.00 0.00 01-JAN-00:10 0.00 02-JAN-09:00
General:Pumps:Electricity 0.00 0.00 01-JAN-00:10 0.00 02-JAN-09:00


Annual and Peak Values - Natural Gas

Natural Gas Annual Value [GJ] Natural Gas Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Natural Gas Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
NaturalGas:Facility 0.19 0.00 01-JAN-00:10 8979.90 27-DEC-07:10
NaturalGas:HVAC 0.19 0.00 01-JAN-00:10 8979.90 27-DEC-07:10
Heating:NaturalGas 0.19 0.00 01-JAN-00:10 8979.90 27-DEC-07:10
General:Heating:NaturalGas 0.19 0.00 01-JAN-00:10 8979.90 27-DEC-07:10


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Cooling Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum {TIMESTAMP} Maximum Value [m3/s] Timestamp of Maximum {TIMESTAMP}
Water:Facility 58.31 0.00 01-JAN-00:10 0.00 02-JAN-12:10
Water:Plant 58.31 0.00 01-JAN-00:10 0.00 02-JAN-12:10
WaterSystems:Water 58.31 0.00 01-JAN-00:10 0.00 02-JAN-12:10
Water Heater:WaterSystems:Water 29.16 0.00 01-JAN-00:10 0.00 27-FEB-12:40
MainsWater:Facility 58.31 0.00 01-JAN-00:10 0.00 02-JAN-12:10
MainsWater:Plant 58.31 0.00 01-JAN-00:10 0.00 02-JAN-12:10
WaterSystems:MainsWater 58.31 0.00 01-JAN-00:10 0.00 02-JAN-12:10
Water Heater:WaterSystems:MainsWater 29.16 0.00 01-JAN-00:10 0.00 27-FEB-12:40
WaterUse:WaterSystems:Water 29.16 0.00 01-JAN-00:10 0.00 31-JAN-12:10
WaterUse:WaterSystems:MainsWater 29.16 0.00 01-JAN-00:10 0.00 31-JAN-12:10


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum {TIMESTAMP} Maximum Value [kg/s] Timestamp of Maximum {TIMESTAMP}
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:10 0.000 01-JAN-00:10
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:10 0.000 01-JAN-00:10


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum {TIMESTAMP} Maximum Value [m3/s] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum {TIMESTAMP} Maximum Value [L] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
EnergyTransfer:Facility 186.42 0.00 01-JAN-00:10 51349.80 07-AUG-07:10
EnergyTransfer:Building 84.32 0.00 01-JAN-00:10 23358.78 03-JUL-07:10
EnergyTransfer:Zone:CORE_ZN 21.93 0.00 01-JAN-00:10 5339.92 12-JUN-07:10
Heating:EnergyTransfer 4.81 0.00 01-JAN-00:10 15503.92 27-DEC-07:10
Heating:EnergyTransfer:Zone:CORE_ZN 0.33 0.00 01-JAN-00:10 1362.92 30-JAN-08:10
General:Heating:EnergyTransfer 4.81 0.00 01-JAN-00:10 15503.92 27-DEC-07:10
General:Heating:EnergyTransfer:Zone:CORE_ZN 0.33 0.00 01-JAN-00:10 1362.92 30-JAN-08:10
Cooling:EnergyTransfer 79.51 0.00 01-JAN-00:10 23358.78 03-JUL-07:10
Cooling:EnergyTransfer:Zone:CORE_ZN 21.60 0.00 01-JAN-00:10 5339.92 12-JUN-07:10
General:Cooling:EnergyTransfer 79.51 0.00 01-JAN-00:10 23358.78 03-JUL-07:10
General:Cooling:EnergyTransfer:Zone:CORE_ZN 21.60 0.00 01-JAN-00:10 5339.92 12-JUN-07:10
EnergyTransfer:Zone:PERIMETER_ZN_1 21.33 0.00 01-JAN-00:10 6149.93 27-DEC-07:10
Heating:EnergyTransfer:Zone:PERIMETER_ZN_1 1.27 0.00 01-JAN-00:10 6149.93 27-DEC-07:10
General:Heating:EnergyTransfer:Zone:PERIMETER_ZN_1 1.27 0.00 01-JAN-00:10 6149.93 27-DEC-07:10
Cooling:EnergyTransfer:Zone:PERIMETER_ZN_1 20.06 0.00 01-JAN-00:10 5732.65 30-OCT-13:10
General:Cooling:EnergyTransfer:Zone:PERIMETER_ZN_1 20.06 0.00 01-JAN-00:10 5732.65 30-OCT-13:10
EnergyTransfer:Zone:PERIMETER_ZN_2 12.90 0.00 01-JAN-00:10 3983.26 03-JUL-07:10
Heating:EnergyTransfer:Zone:PERIMETER_ZN_2 0.64 0.00 01-JAN-00:10 2290.27 27-DEC-07:10
General:Heating:EnergyTransfer:Zone:PERIMETER_ZN_2 0.64 0.00 01-JAN-00:10 2290.27 27-DEC-07:10
Cooling:EnergyTransfer:Zone:PERIMETER_ZN_2 12.26 0.00 01-JAN-00:10 3983.26 03-JUL-07:10
General:Cooling:EnergyTransfer:Zone:PERIMETER_ZN_2 12.26 0.00 01-JAN-00:10 3983.26 03-JUL-07:10
EnergyTransfer:Zone:PERIMETER_ZN_3 15.94 0.00 01-JAN-00:10 5290.14 03-JUL-07:10
Heating:EnergyTransfer:Zone:PERIMETER_ZN_3 1.70 0.00 01-JAN-00:10 3712.45 30-JAN-07:10
General:Heating:EnergyTransfer:Zone:PERIMETER_ZN_3 1.70 0.00 01-JAN-00:10 3712.45 30-JAN-07:10
Cooling:EnergyTransfer:Zone:PERIMETER_ZN_3 14.24 0.00 01-JAN-00:10 5290.14 03-JUL-07:10
General:Cooling:EnergyTransfer:Zone:PERIMETER_ZN_3 14.24 0.00 01-JAN-00:10 5290.14 03-JUL-07:10
EnergyTransfer:Zone:PERIMETER_ZN_4 12.21 0.00 01-JAN-00:10 4284.65 07-AUG-16:00
Heating:EnergyTransfer:Zone:PERIMETER_ZN_4 0.87 0.00 01-JAN-00:10 2270.61 27-DEC-07:10
General:Heating:EnergyTransfer:Zone:PERIMETER_ZN_4 0.87 0.00 01-JAN-00:10 2270.61 27-DEC-07:10
Cooling:EnergyTransfer:Zone:PERIMETER_ZN_4 11.34 0.00 01-JAN-00:10 4284.65 07-AUG-16:00
General:Cooling:EnergyTransfer:Zone:PERIMETER_ZN_4 11.34 0.00 01-JAN-00:10 4284.65 07-AUG-16:00
EnergyTransfer:Zone:ATTIC 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Heating:EnergyTransfer:Zone:ATTIC 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Heating:EnergyTransfer:Zone:ATTIC 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Cooling:EnergyTransfer:Zone:ATTIC 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Cooling:EnergyTransfer:Zone:ATTIC 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
PlantLoopHeatingDemand:Facility 0.00 0.00 01-JAN-00:10 85.59 02-JAN-07:10
PlantLoopHeatingDemand:Plant 0.00 0.00 01-JAN-00:10 85.59 02-JAN-07:10
WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:10 85.59 02-JAN-07:10
General:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:10 85.59 02-JAN-07:10
EnergyTransfer:HVAC 102.10 0.00 01-JAN-00:10 29692.19 17-JUL-07:10
CoolingCoils:EnergyTransfer 98.29 0.00 01-JAN-00:10 29692.19 17-JUL-07:10
HeatingCoils:EnergyTransfer 3.82 0.00 01-JAN-00:10 18917.94 27-DEC-07:10
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
EnergyTransfer:Plant 0.00 0.00 01-JAN-00:10 85.59 02-JAN-07:10
WaterSystems:EnergyTransfer 0.00 0.00 01-JAN-00:10 85.59 02-JAN-07:10
WaterUse:WaterSystems:EnergyTransfer 0.00 0.00 01-JAN-00:10 85.59 02-JAN-07:10



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

Annual Building Sensible Heat Gain Components

HVAC Zone Eq & Other Sensible Air Heating [GJ] HVAC Zone Eq & Other Sensible Air Cooling [GJ] HVAC Terminal Unit Sensible Air Heating [GJ] HVAC Terminal Unit Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
CORE_ZN 0.000 0.000 0.331 -21.601 0.000 0.000 5.005 8.499 14.140 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 -6.375
PERIMETER_ZN_1 0.000 0.000 1.271 -20.061 0.000 0.000 3.833 5.441 10.719 18.481 0.000 0.980 0.000 0.000 -7.591 0.000 -3.809 -9.262
PERIMETER_ZN_2 0.000 0.000 0.642 -12.259 0.000 0.000 1.676 3.351 6.359 9.127 0.000 0.020 0.000 0.000 -3.883 0.000 -0.241 -4.792
PERIMETER_ZN_3 0.000 0.000 1.696 -14.244 0.000 0.000 3.936 5.873 10.719 4.663 0.000 0.036 0.000 0.000 -5.972 0.000 -0.338 -6.367
PERIMETER_ZN_4 0.000 0.000 0.870 -11.342 0.000 0.000 2.295 3.353 6.359 9.185 0.000 0.018 0.000 0.000 -4.244 0.000 -0.250 -6.244
ATTIC 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.257 30.259 0.000 0.000 0.000 -42.516 -0.000
Total Facility 0.000 0.000 4.810 -79.508 0.000 0.000 16.744 26.516 48.296 41.456 0.000 13.312 30.260 0.000 -21.690 0.000 -47.155 -33.040


Peak Cooling Sensible Heat Gain Components

Time of Peak {TIMESTAMP} HVAC Zone Eq & Other Sensible Air Heating [W] HVAC Zone Eq & Other Sensible Air Cooling [W] HVAC Terminal Unit Sensible Air Heating [W] HVAC Terminal Unit Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
CORE_ZN 31-OCT-07:02 0.00 0.00 0.00 -5910.12 0.00 0.00 507.37 593.08 973.59 0.00 0.00 0.00 3836.09 0.00 -0.00 0.00 0.00 0.00
PERIMETER_ZN_1 23-OCT-07:02 0.00 0.00 0.00 -6108.71 0.00 0.00 403.20 374.52 738.04 279.46 0.00 0.00 4539.85 0.00 -0.00 0.00 -226.37 0.00
PERIMETER_ZN_2 28-AUG-06:01 0.00 0.00 0.00 -4388.94 0.00 0.00 38.14 109.80 218.91 602.47 0.00 0.00 3423.31 0.00 -0.00 0.00 -3.67 0.00
PERIMETER_ZN_3 28-AUG-06:01 0.00 0.00 0.00 -6058.31 0.00 0.00 64.29 187.06 369.02 0.00 0.00 0.00 5494.07 0.00 -50.56 0.00 -5.58 0.00
PERIMETER_ZN_4 04-JUL-17:11 0.00 0.00 0.00 -5350.28 0.00 0.00 0.00 46.30 74.74 0.00 0.00 0.00 5276.68 0.00 -36.17 0.00 -11.26 0.00
ATTIC - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 28-AUG-06:01 0.00 0.00 0.00 -27144.40 0.00 0.00 289.65 891.51 1662.65 602.47 0.00 579.32 24466.65 0.00 -424.96 0.00 -922.89 0.00


Peak Heating Sensible Heat Gain Components

Time of Peak {TIMESTAMP} HVAC Zone Eq & Other Sensible Air Heating [W] HVAC Zone Eq & Other Sensible Air Cooling [W] HVAC Terminal Unit Sensible Air Heating [W] HVAC Terminal Unit Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
CORE_ZN 05-DEC-08:62 0.00 0.00 5728.77 0.00 0.00 0.00 692.70 593.08 973.59 0.00 0.00 0.00 0.00 0.00 -0.00 0.00 0.00 -7988.14
PERIMETER_ZN_1 09-JAN-07:01 0.00 0.00 8410.48 0.00 0.00 0.00 117.25 209.81 369.02 0.00 0.00 0.00 0.00 0.00 -684.37 0.00 -2274.00 -6148.19
PERIMETER_ZN_2 09-JAN-07:01 0.00 0.00 6280.13 0.00 0.00 0.00 71.90 124.46 218.91 0.00 0.00 0.00 0.00 0.00 -343.45 0.00 -9.65 -6342.30
PERIMETER_ZN_3 09-JAN-07:01 0.00 0.00 8604.57 0.00 0.00 0.00 121.21 209.81 369.02 0.00 0.00 0.00 0.00 0.00 -503.94 0.00 -14.22 -8786.45
PERIMETER_ZN_4 09-JAN-07:01 0.00 0.00 7315.53 0.00 0.00 0.00 71.97 124.46 218.91 0.00 0.00 0.00 0.00 0.00 -341.01 0.00 -9.79 -7380.07
ATTIC - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 30-JAN-07:01 0.00 0.00 32342.29 0.00 0.00 0.00 532.92 945.30 1662.65 0.00 0.00 1002.94 0.00 0.00 -2392.92 0.00 -3005.35 -31087.82



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Origin of D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Calculation Method for Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA Environment Name of Peak System Population - Ps Date and Time of Last Peak System Population - Ps
PSZ-AC:1 0.3376 0.0000 8.0545 1.0000 Calculated from schedules 0.0646 0.3376 0.1914 1.0000 Not calculated 0.0646 0.1914    
PSZ-AC:2 0.3887 0.0000 6.1058 1.0000 Calculated from schedules 0.0490 0.3887 0.1260 1.0000 Not calculated 0.0490 0.1260    
PSZ-AC:3 0.2836 0.0000 3.6221 1.0000 Calculated from schedules 0.0291 0.2836 0.1025 1.0000 Not calculated 0.0291 0.1025    
PSZ-AC:4 0.3836 0.0000 6.1058 1.0000 Calculated from schedules 0.0490 0.3836 0.1277 1.0000 Not calculated 0.0490 0.1277    
PSZ-AC:5 0.3429 0.0000 3.6221 1.0000 Calculated from schedules 0.0291 0.3429 0.0848 1.0000 Not calculated 0.0291 0.0848    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Origin of D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Calculation Method for Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA Environment Name of Peak System Population - Ps Date and Time of Last Peak System Population - Ps
PSZ-AC:1 0.3376 0.0000 8.0545 1.0000 Calculated from schedules 0.0646 0.3376 1.0000 1.0000 Not calculated 0.0646 0.1914    
PSZ-AC:2 0.3887 0.0000 6.1058 1.0000 Calculated from schedules 0.0490 0.3887 1.0000 1.0000 Not calculated 0.0490 0.1260    
PSZ-AC:3 0.2836 0.0000 3.6221 1.0000 Calculated from schedules 0.0291 0.2836 1.0000 1.0000 Not calculated 0.0291 0.1025    
PSZ-AC:4 0.3836 0.0000 6.1058 1.0000 Calculated from schedules 0.0490 0.3836 1.0000 1.0000 Not calculated 0.0490 0.1277    
PSZ-AC:5 0.3429 0.0000 3.6221 1.0000 Calculated from schedules 0.0291 0.3429 1.0000 1.0000 Not calculated 0.0291 0.0848    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
CORE_ZN PSZ-AC:1 0.002360 8.0545 0.000305 149.66 0.0646 1.0000 0.0646 1.000 0.0646
PERIMETER_ZN_1 PSZ-AC:2 0.002360 6.1058 0.000305 113.45 0.0490 1.0000 0.0490 1.000 0.0490
PERIMETER_ZN_2 PSZ-AC:3 0.002360 3.6221 0.000305 67.30 0.0291 1.0000 0.0291 1.000 0.0291
PERIMETER_ZN_3 PSZ-AC:4 0.002360 6.1058 0.000305 113.45 0.0490 1.0000 0.0490 1.000 0.0490
PERIMETER_ZN_4 PSZ-AC:5 0.002360 3.6221 0.000305 67.30 0.0291 1.0000 0.0291 1.000 0.0291


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
PSZ-AC:1 0.002360 8.05 0.000305 149.6574 0.0646 0.0646 0.0646
PSZ-AC:2 0.002360 6.11 0.000305 113.4500 0.0490 0.0490 0.0490
PSZ-AC:3 0.002360 3.62 0.000305 67.3000 0.0291 0.0291 0.0291
PSZ-AC:4 0.002360 6.11 0.000305 113.4500 0.0490 0.0490 0.0490
PSZ-AC:5 0.002360 3.62 0.000305 67.3000 0.0291 0.0291 0.0291


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
CORE_ZN PSZ-AC:1 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3376 0.3376 0.3376 No 0.0646 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_ZN_1 PSZ-AC:2 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3887 0.3887 0.3887 No 0.0490 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_ZN_2 PSZ-AC:3 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.2836 0.2836 0.2836 No 0.0291 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_ZN_3 PSZ-AC:4 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3836 0.3836 0.3836 No 0.0490 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_ZN_4 PSZ-AC:5 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3429 0.3429 0.3429 No 0.0291 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
PSZ-AC:1 0.3376 0.3376 0.3376 0.3376 0.0646 1.0000
PSZ-AC:2 0.3887 0.3887 0.3887 0.3887 0.0490 1.0000
PSZ-AC:3 0.2836 0.2836 0.2836 0.2836 0.0291 1.0000
PSZ-AC:4 0.3836 0.3836 0.3836 0.3836 0.0490 1.0000
PSZ-AC:5 0.3429 0.3429 0.3429 0.3429 0.0291 1.0000


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
CORE_ZN PSZ-AC:1 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3376 0.3376 0.3376 No 0.0646 1.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_ZN_1 PSZ-AC:2 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3887 0.3887 0.3887 No 0.0490 0.2908 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_ZN_2 PSZ-AC:3 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.2836 0.2836 0.2836 No 0.0291 0.2703 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_ZN_3 PSZ-AC:4 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3836 0.3836 0.3836 No 0.0490 0.2933 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_ZN_4 PSZ-AC:5 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.3429 0.3429 0.3429 No 0.0291 0.2723 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
PSZ-AC:1 0.3376 0.3376 0.3376 0.3376 0.0646 1.0000
PSZ-AC:2 0.3887 0.3887 0.3887 0.3887 0.0490 1.0000
PSZ-AC:3 0.2836 0.2836 0.2836 0.2836 0.0291 1.0000
PSZ-AC:4 0.3836 0.3836 0.3836 0.3836 0.0490 1.0000
PSZ-AC:5 0.3429 0.3429 0.3429 0.3429 0.0291 1.0000



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

Sec1.1A-General Information

Data
Weather File RUNPERIOD 1 ** El Paso International Ap Ut TX USA TMY3 WMO#=722700
Total gross floor area [m2] 511.16
Principal Heating Source Electricity


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
CORE_ZN 149.66 149.66 0.00 82.16
PERIMETER_ZN_1 113.45 113.45 0.00 82.16
PERIMETER_ZN_2 67.30 67.30 0.00 67.66
PERIMETER_ZN_3 113.45 113.45 0.00 82.16
PERIMETER_ZN_4 67.30 67.30 0.00 82.16
ATTIC 567.98 0.00 567.98 0.00
Totals 511.16 511.16 0.00  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 0.00
Number of hours cooling loads not met 122.83
Number of hours not met 122.83


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electricity Energy Use [GJ] Electricity Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Gasoline Use [GJ] Gasoline Demand [W] Diesel Use [GJ] Diesel Demand [W] Coal Use [GJ] Coal Demand [W] Fuel Oil No 1 Use [GJ] Fuel Oil No 1 Demand [W] Fuel Oil No 2 Use [GJ] Fuel Oil No 2 Demand [W] Propane Use [GJ] Propane Demand [W] Other Fuel 1 Use [GJ] Other Fuel 1 Demand [W] Other Fuel 2 Use [GJ] Other Fuel 2 Demand [W] District Cooling Use [GJ] District Cooling Demand [W] District Heating Use [GJ] District Heating Demand [W]
Heating -- General 2.03 7139.25 0.19 8979.90 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling -- General 22.80 7046.34 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting -- LightsWired 26.52 2025.66 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting -- General 9.71 1049.10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment -- MiscPlug 48.30 3325.31 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans -- General 22.99 1944.98 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps -- General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems -- General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems -- Water Heater 23.43 2797.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems -- WaterUse 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators -- General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 48.30 155.77
Natural Gas 0.00 0.19
Additional 0.00 0.00
Total 48.30 155.97


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting (All) 51.88
Space Heating 3.97
Space Cooling 44.60
Fans (All) 44.97
Service Water Heating 45.84
Receptacle Equipment 94.48
Miscellaneous (All) 304.74
Subtotal 304.74


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 0.38
Service Water Heating 0.00
Miscellaneous (All) 0.38
Subtotal 0.38


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Subtotal 0.00
Miscellaneous 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting (All) 17.00
Space Heating 1.43
Space Cooling 14.62
Fans (All) 14.74
Service Water Heating 15.02
Receptacle Equipment 30.97
Miscellaneous 6.23


Schedules-Equivalent Full Load Hours (Schedule Type=Fraction)

Equivalent Full Load Hours of Operation Per Year [hr] Hours > 1% [hr]
LTG_SCH_OFFICE 2635. 8760.
BLDG_EQUIP_SCH 3948. 8760.
BLDG_OCC_SCH 2512. 4420.
BLDG_OCC_SCH_W_SB 1854. 3640.
BLDG_OCC_SCH_WO_SB 2533. 4420.
BINARY OCCUPANCY 4420. 4420.
INFIL_QUARTER_ON_SCH 5991. 8760.
INFIL_DOOR_OPENING_SCH 1154. 3380.
BLDG_SWH_SCH 2064. 3900.
ALWAYS_ON 8760. 8760.
EXTERIOR_LGT_ALWAYS_ON 8760. 8760.
EXTERIOR_LGT_189_1 6200. 8760.
ALWAYS_OFF 0. 0.
HVACOPERATIONSCHD_W_SB 2600. 2600.
REHEATCOILAVAILSCHED 8760. 8760.
COOLINGCOILAVAILSCHED 8760. 8760.
MINOA_MOTORIZEDDAMPER_SCHED 3120. 3120.
MINOA_SCHED 8760. 8760.
WORK_EFF_SCH 0. 0.
CORE_ZN WATER EQUIPMENT LATENT FRACT SCHED 438. 8760.
CORE_ZN WATER EQUIPMENT SENSIBLE FRACT SCHED 1752. 8760.
EXTERIOR_LIGHTING_SCHEDULE_A 6570. 6570.
EXTERIOR_LIGHTING_SCHEDULE_B 8103. 8760.
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 3120. 3120.
EXTERIOR_LIGHTING_SCHEDULE_B_2016 7665. 8760.
EXTERIOR_LIGHTING_SCHEDULE_C_2016 6752. 8760.


Schedules-SetPoints (Schedule Type=Temperature)

First Object Used Month Assumed 11am First Wednesday [C] Days with Same 11am Value 11pm First Wednesday [C] Days with Same 11pm Value
HTGSETP_SCH_YES_OPTIMUM_STARTSTOP CORE_ZN DUAL SP CONTROL January 21.11 365 15.56 365
CLGSETP_SCH_YES_OPTIMUM_STARTSTOP CORE_ZN DUAL SP CONTROL July 23.89 365 29.44 365



Table of Contents

Report: Annual Thermal Resilience Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

Heat Index Hours

Safe (≤ 26.7°C) [hr] Caution (> 26.7, ≤ 32.2°C) [hr] Extreme Caution (> 32.2, ≤ 39.4°C) [hr] Danger (> 39.4, ≤ 51.7°C) [hr] Extreme Danger (> 51.7°C) [hr]
CORE_ZN 7041.67 1718.33 0.00 0.00 0.00
PERIMETER_ZN_1 7436.83 1323.17 0.00 0.00 0.00
PERIMETER_ZN_2 7284.17 1475.83 0.00 0.00 0.00
PERIMETER_ZN_3 7607.67 1152.33 0.00 0.00 0.00
PERIMETER_ZN_4 6992.50 1767.50 0.00 0.00 0.00
ATTIC 5855.50 787.50 700.33 1059.83 356.83
Min 5855.50 787.50 0.00 0.00 0.00
Max 7607.67 1767.50 700.33 1059.83 356.83
Average 7036.39 1370.78 116.72 176.64 59.47
Sum 42218.33 8224.67 700.33 1059.83 356.83


Heat Index OccupantHours

Safe (≤ 26.7°C) [hr] Caution (> 26.7, ≤ 32.2°C) [hr] Extreme Caution (> 32.2, ≤ 39.4°C) [hr] Danger (> 39.4, ≤ 51.7°C) [hr] Extreme Danger (> 51.7°C) [hr]
CORE_ZN 17892.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_1 13356.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_2 4788.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_3 13356.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_4 6804.00 0.00 0.00 0.00 0.00
ATTIC 0.00 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00 0.00
Max 17892.00 0.00 0.00 0.00 0.00
Average 9366.00 0.00 0.00 0.00 0.00
Sum 56196.00 0.00 0.00 0.00 0.00


Humidex Hours

Little to no Discomfort (≤ 29) [hr] Some Discomfort (> 29, ≤ 40) [hr] Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] Dangerous (> 45, ≤ 50) [hr] Heat Stroke Quite Possible (> 50) [hr]
CORE_ZN 6769.17 1990.83 0.00 0.00 0.00
PERIMETER_ZN_1 7528.67 1231.33 0.00 0.00 0.00
PERIMETER_ZN_2 7477.50 1282.50 0.00 0.00 0.00
PERIMETER_ZN_3 7633.67 1126.33 0.00 0.00 0.00
PERIMETER_ZN_4 7276.67 1483.33 0.00 0.00 0.00
ATTIC 6078.50 1107.83 376.00 348.67 849.00
Min 6078.50 1107.83 0.00 0.00 0.00
Max 7633.67 1990.83 376.00 348.67 849.00
Average 7127.36 1370.36 62.67 58.11 141.50
Sum 42764.17 8222.17 376.00 348.67 849.00


Humidex OccupantHours

Little to no Discomfort (≤ 29) [hr] Some Discomfort (> 29, ≤ 40) [hr] Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] Dangerous (> 45, ≤ 50) [hr] Heat Stroke Quite Possible (> 50) [hr]
CORE_ZN 17836.00 56.00 0.00 0.00 0.00
PERIMETER_ZN_1 13316.50 39.50 0.00 0.00 0.00
PERIMETER_ZN_2 4787.00 1.00 0.00 0.00 0.00
PERIMETER_ZN_3 13336.33 19.67 0.00 0.00 0.00
PERIMETER_ZN_4 6803.50 0.50 0.00 0.00 0.00
ATTIC 0.00 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00 0.00
Max 17836.00 56.00 0.00 0.00 0.00
Average 9346.56 19.44 0.00 0.00 0.00
Sum 56079.33 116.67 0.00 0.00 0.00


Heating SET Hours

SET ≤ 12.2°C Hours (°C) SET ≤ 12.2°C OccupantHours (°C) Longest SET ≤ 12.2°C Duration [hr] Start Time of the Longest SET ≤ 12.2°C Duration
None        


Cooling SET Hours

SET > 30°C Hours (°C) SET > 30°C OccupantHours (°C) Longest SET > 30°C Duration [hr] Start Time of the Longest SET > 30°C Duration
None        



Table of Contents

Report: Annual CO2 Resilience Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

CO2 Level Hours

Safe (<= 1000 ppm) [hr] Caution (> 1000, <= 5000 ppm) [hr] Hazard (> 5000 ppm) [hr]
None      


CO2 Level OccupantHours

Safe (<= 1000 ppm) [hr] Caution (> 1000, <= 5000 ppm) [hr] Hazard (> 5000 ppm) [hr]
None      



Table of Contents

Report: Annual Visual Resilience Summary

For: Entire Facility

Timestamp: 2023-10-16 08:29:45

Illuminance Level Hours

A Bit Dark (<= 100 lux) [hr] Dim (> 100, <= 300 lux) [hr] Adequate (> 300, <= 500 lux) [hr] Bright (>500 lux) [hr]
CORE_ZN 0.00 0.00 0.00 0.00
PERIMETER_ZN_1 0.00 0.00 8760.00 0.00
PERIMETER_ZN_2 0.00 0.00 8760.00 0.00
PERIMETER_ZN_3 0.00 0.00 8760.00 0.00
PERIMETER_ZN_4 0.00 0.00 8760.00 0.00
ATTIC 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00
Max 0.00 0.00 8760.00 0.00
Average 0.00 0.00 5840.00 0.00
Sum 0.00 0.00 35040.00 0.00


Illuminance Level OccupantHours

A Bit Dark (<= 100 lux) [hr] Dim (> 100, <= 300 lux) [hr] Adequate (> 300, <= 500 lux) [hr] Bright (>500 lux) [hr]
CORE_ZN 0.00 0.00 0.00 0.00
PERIMETER_ZN_1 0.00 0.00 13356.00 0.00
PERIMETER_ZN_2 0.00 0.00 4788.00 0.00
PERIMETER_ZN_3 0.00 0.00 13356.00 0.00
PERIMETER_ZN_4 0.00 0.00 6804.00 0.00
ATTIC 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00
Max 0.00 0.00 13356.00 0.00
Average 0.00 0.00 6384.00 0.00
Sum 0.00 0.00 38304.00 0.00



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR

For: Environment

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 8.136
February 10.272
March 12.546
April 19.230
May 23.842
June 27.856
July 27.543
August 26.276
September 23.380
October 18.301
November 11.185
December 6.787
   
Annual Sum or Average 17.982
Minimum of Months 6.787
Maximum of Months 27.856



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC

For: Environment

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 8.136
February 10.272
March 12.546
April 19.230
May 23.842
June 27.856
July 27.543
August 26.276
September 23.380
October 18.301
November 11.185
December 6.787
   
Annual Sum or Average 17.982
Minimum of Months 6.787
Maximum of Months 27.856



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2021

For: Environment

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 8.136
February 10.272
March 12.546
April 19.230
May 23.842
June 27.856
July 27.543
August 26.276
September 23.380
October 18.301
November 11.185
December 6.787
   
Annual Sum or Average 17.982
Minimum of Months 6.787
Maximum of Months 27.856



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND

For: Environment

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 8.136
February 10.272
March 12.546
April 19.230
May 23.842
June 27.856
July 27.543
August 26.276
September 23.380
October 18.301
November 11.185
December 6.787
   
Annual Sum or Average 17.982
Minimum of Months 6.787
Maximum of Months 27.856



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME OFFICESMALL

For: Environment

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 8.136
February 10.272
March 12.546
April 19.230
May 23.842
June 27.856
July 27.543
August 26.276
September 23.380
October 18.301
November 11.185
December 6.787
   
Annual Sum or Average 17.982
Minimum of Months 6.787
Maximum of Months 27.856



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL

For: Environment

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 8.136
February 10.272
March 12.546
April 19.230
May 23.842
June 27.856
July 27.543
August 26.276
September 23.380
October 18.301
November 11.185
December 6.787
   
Annual Sum or Average 17.982
Minimum of Months 6.787
Maximum of Months 27.856



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL

For: Environment

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 8.136
February 10.272
March 12.546
April 19.230
May 23.842
June 27.856
July 27.543
August 26.276
September 23.380
October 18.301
November 11.185
December 6.787
   
Annual Sum or Average 17.982
Minimum of Months 6.787
Maximum of Months 27.856



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 3B

For: Environment

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 8.136
February 10.272
March 12.546
April 19.230
May 23.842
June 27.856
July 27.543
August 26.276
September 23.380
October 18.301
November 11.185
December 6.787
   
Annual Sum or Average 17.982
Minimum of Months 6.787
Maximum of Months 27.856



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_TX_ELPASO

For: Environment

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 8.136
February 10.272
March 12.546
April 19.230
May 23.842
June 27.856
July 27.543
August 26.276
September 23.380
October 18.301
November 11.185
December 6.787
   
Annual Sum or Average 17.982
Minimum of Months 6.787
Maximum of Months 27.856



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.521016E+09 1481.65 27-JAN-08:05 -3.5 -7.2 0.264835E+09 402.34 12-JAN-14:50 -3.5 -7.2
February 0.502679E+09 1380.22 03-FEB-08:05 -2.0 -5.0 0.249803E+09 402.94 21-FEB-11:30 20.00 7.36
March 0.761610E+09 1700.64 16-MAR-15:55 22.20 8.37 0.314479E+09 402.33 14-MAR-09:50 22.20 8.37
April 0.137848E+10 5702.12 24-APR-07:02 13.58 5.93 0.285561E+09 469.21 20-APR-07:10 13.58 5.93
May 0.243368E+10 5791.85 02-MAY-07:02 12.57 5.95 0.317824E+09 469.22 18-MAY-07:10 18.17 13.54
June 0.311451E+10 5854.02 12-JUN-06:01 18.03 7.04 0.321553E+09 469.22 19-JUN-07:10 24.50 16.82
July 0.292780E+10 5413.29 03-JUL-05:02 27.62 17.62 0.300015E+09 469.23 31-JUL-07:10 23.07 18.31
August 0.327516E+10 5623.13 23-AUG-06:02 20.28 12.08 0.340035E+09 469.23 24-AUG-07:10 23.95 16.08
September 0.273829E+10 5615.59 11-SEP-06:01 16.05 10.85 0.292008E+09 469.23 05-SEP-07:10 16.05 10.85
October 0.217311E+10 5909.94 31-OCT-07:02 11.33 5.47 0.302361E+09 469.24 02-OCT-07:10 11.33 5.47
November 0.118932E+10 5618.73 09-NOV-08:62 15.28 6.89 0.293686E+09 463.21 10-NOV-08:09 17.88 11.42
December 0.585285E+09 1401.10 27-DEC-08:05 -3.4 -4.3 0.253504E+09 402.33 14-DEC-15:00 -3.4 -4.3
                     
Annual Sum or Average 0.216010E+11         0.353566E+10        
Minimum of Months 0.502679E+09 1380.22   -3.5 -7.2 0.249803E+09 402.33   -3.5 -7.2
Maximum of Months 0.327516E+10 5909.94   27.62 17.62 0.340035E+09 469.24   24.50 18.31



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.558296E+09 2831.55 12-JAN-14:55 18.90 10.02 0.203113E+09 304.99 03-JAN-13:09 18.90 10.02
February 0.441500E+09 2604.43 22-FEB-13:50 21.52 7.85 0.184304E+09 304.99 06-FEB-13:09 21.52 7.85
March 0.440351E+09 2233.99 16-MAR-14:40 22.80 8.93 0.225328E+09 309.24 03-MAR-15:09 22.80 8.93
April 0.773975E+09 2886.58 21-APR-14:25 32.20 15.35 0.209984E+09 313.88 20-APR-07:10 32.20 15.35
May 0.162381E+10 5688.58 15-MAY-07:01 21.97 11.12 0.238826E+09 355.69 30-MAY-07:10 25.78 12.49
June 0.264052E+10 5978.78 19-JUN-06:01 23.07 16.06 0.242062E+09 355.70 19-JUN-07:10 24.50 16.82
July 0.274742E+10 5786.64 03-JUL-06:01 26.88 16.13 0.221299E+09 355.70 03-JUL-07:10 27.98 16.41
August 0.311967E+10 6087.93 28-AUG-06:01 20.37 14.83 0.254147E+09 355.70 07-AUG-07:10 20.37 14.83
September 0.298426E+10 6033.58 11-SEP-06:01 16.05 10.85 0.221554E+09 355.69 22-SEP-07:10 21.47 18.37
October 0.262694E+10 6108.54 23-OCT-07:02 13.27 9.81 0.229396E+09 355.70 02-OCT-07:10 13.27 9.81
November 0.156966E+10 5861.06 10-NOV-08:62 17.88 11.42 0.217829E+09 334.05 10-NOV-08:09 17.88 11.42
December 0.535113E+09 2389.06 18-DEC-13:10 9.50 0.16 0.194021E+09 304.99 01-DEC-13:09 9.50 0.16
                     
Annual Sum or Average 0.200615E+11         0.264186E+10        
Minimum of Months 0.440351E+09 2233.99   9.50 0.16 0.184304E+09 304.99   9.50 0.16
Maximum of Months 0.311967E+10 6108.54   32.20 16.13 0.254147E+09 355.70   32.20 18.37



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 40041270.25 494.73 27-JAN-07:04 -4.3 -7.5 80118544.56 180.92 03-JAN-16:10 -4.3 -7.5
February 60740811.49 512.14 03-FEB-07:04 -5.1 -7.2 76064776.34 180.98 21-FEB-11:09 20.00 7.35
March 0.157369E+09 735.45 16-MAR-10:43 20.32 8.43 98054913.71 181.28 06-MAR-15:09 20.32 8.43
April 0.673268E+09 4273.85 28-APR-07:02 16.57 10.52 93386026.54 208.00 28-APR-07:10 16.57 10.52
May 0.143478E+10 4277.98 12-MAY-07:01 16.05 8.72 0.105270E+09 211.00 22-MAY-07:10 21.05 15.19
June 0.206514E+10 4317.10 19-JUN-06:01 23.07 16.06 0.106539E+09 211.01 26-JUN-07:10 22.15 15.43
July 0.208327E+10 4207.56 03-JUL-06:01 26.88 16.13 97498383.59 211.01 24-JUL-07:10 23.48 18.08
August 0.226919E+10 4388.87 28-AUG-06:01 20.37 14.83 0.111490E+09 211.01 08-AUG-07:10 20.37 14.83
September 0.185019E+10 4372.71 11-SEP-06:01 16.05 10.85 96655735.63 211.01 05-SEP-07:10 16.05 10.85
October 0.116012E+10 4339.04 23-OCT-07:02 13.27 9.81 99639569.00 211.00 02-OCT-07:10 13.27 9.81
November 0.414276E+09 4215.71 10-NOV-08:62 17.88 11.42 93543151.36 211.00 10-NOV-08:09 17.88 11.42
December 50638136.41 501.92 07-DEC-07:03 -1.5 -3.4 76903944.63 181.41 01-DEC-13:09 -1.5 -3.4
                     
Annual Sum or Average 0.122590E+11         0.113516E+10        
Minimum of Months 40041270.25 494.73   -5.1 -7.5 76064776.34 180.92   -4.3 -7.5
Maximum of Months 0.226919E+10 4388.87   26.88 16.13 0.111490E+09 211.01   23.48 18.08



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 44751101.98 924.86 27-JAN-07:04 -4.3 -7.5 0.174259E+09 295.83 13-JAN-16:30 -4.3 -7.5
February 44773509.82 818.61 10-FEB-07:05 -2.8 -5.3 0.162899E+09 304.99 23-FEB-16:49 17.98 6.94
March 78680298.50 775.74 02-MAR-07:04 -1.6 -4.8 0.211049E+09 305.10 07-MAR-16:49 21.10 8.36
April 0.573906E+09 4728.21 20-APR-07:02 20.60 8.60 0.211051E+09 326.47 20-APR-07:10 20.60 8.60
May 0.159227E+10 5829.21 12-MAY-07:01 16.05 8.72 0.239840E+09 357.17 09-MAY-07:10 16.05 8.72
June 0.253286E+10 5935.74 19-JUN-06:01 23.07 16.06 0.242450E+09 355.70 22-JUN-07:10 21.20 15.49
July 0.267124E+10 5735.42 03-JUL-06:01 26.88 16.13 0.221251E+09 355.70 03-JUL-07:10 27.98 16.41
August 0.283421E+10 6058.23 28-AUG-06:01 20.37 14.83 0.253638E+09 355.70 07-AUG-07:10 20.37 14.83
September 0.217129E+10 5864.45 11-SEP-06:01 16.05 10.85 0.219601E+09 355.70 19-SEP-07:10 20.15 14.86
October 0.130001E+10 5893.07 02-OCT-06:01 22.70 15.09 0.227238E+09 355.70 02-OCT-07:10 22.02 15.21
November 0.341411E+09 3423.24 10-NOV-08:62 17.88 11.42 0.208182E+09 319.69 10-NOV-08:09 17.88 11.42
December 59045387.34 885.79 22-DEC-07:04 -3.0 -4.9 0.167392E+09 292.68 01-DEC-15:09 -3.0 -4.9
                     
Annual Sum or Average 0.142445E+11         0.253885E+10        
Minimum of Months 44751101.98 775.74   -4.3 -7.5 0.162899E+09 292.68   -4.3 -7.5
Maximum of Months 0.283421E+10 6058.23   26.88 16.13 0.253638E+09 357.17   27.98 16.41



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 35641329.49 705.57 12-JAN-16:02 18.72 10.12 0.111105E+09 182.08 02-JAN-15:39 18.72 10.12
February 41607741.15 922.84 21-FEB-16:53 22.20 7.81 0.102513E+09 184.38 21-FEB-14:09 22.20 7.81
March 0.110889E+09 1310.79 16-MAR-15:53 22.20 8.37 0.131751E+09 184.90 06-MAR-14:39 22.20 8.37
April 0.536523E+09 4767.83 20-APR-07:02 20.60 8.60 0.127273E+09 207.91 20-APR-07:10 20.60 8.60
May 0.125913E+10 5028.65 12-MAY-07:01 16.05 8.72 0.143633E+09 211.00 22-MAY-07:10 21.05 15.19
June 0.187931E+10 5121.95 19-JUN-06:01 23.07 16.06 0.144924E+09 211.01 26-JUN-07:10 22.15 15.43
July 0.196401E+10 5350.43 04-JUL-17:11 26.77 18.89 0.131864E+09 211.00 03-JUL-07:10 26.77 18.89
August 0.214133E+10 5215.41 13-AUG-17:02 31.10 18.43 0.151220E+09 211.01 07-AUG-07:10 31.10 18.43
September 0.176269E+10 5231.60 11-SEP-06:01 16.05 10.85 0.131510E+09 211.01 18-SEP-07:10 21.05 15.73
October 0.115263E+10 5087.63 02-OCT-06:01 22.70 15.09 0.136174E+09 211.00 02-OCT-07:10 22.02 15.21
November 0.414408E+09 4330.68 10-NOV-08:62 17.88 11.42 0.127784E+09 202.46 10-NOV-08:09 17.88 11.42
December 43786056.81 659.57 15-DEC-16:23 15.30 6.01 0.106485E+09 180.92 15-DEC-15:20 15.30 6.01
                     
Annual Sum or Average 0.113420E+11         0.154624E+10        
Minimum of Months 35641329.49 659.57   15.30 6.01 0.102513E+09 180.92   15.30 6.01
Maximum of Months 0.214133E+10 5350.43   31.10 18.89 0.151220E+09 211.01   31.10 18.89



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: ATTIC

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.00 0.00 01-JAN-00:10 6.70 3.92 0.00 0.00 01-JAN-00:10 6.70 3.92
February 0.00 0.00 01-FEB-00:10 6.42 1.84 0.00 0.00 01-FEB-00:10 6.42 1.84
March 0.00 0.00 01-MAR-00:10 7.32 2.40 0.00 0.00 01-MAR-00:10 7.32 2.40
April 0.00 0.00 01-APR-00:10 11.18 2.41 0.00 0.00 01-APR-00:10 11.18 2.41
May 0.00 0.00 01-MAY-00:10 20.40 8.41 0.00 0.00 01-MAY-00:10 20.40 8.41
June 0.00 0.00 01-JUN-00:10 25.03 11.56 0.00 0.00 01-JUN-00:10 25.03 11.56
July 0.00 0.00 01-JUL-00:10 27.63 17.07 0.00 0.00 01-JUL-00:10 27.63 17.07
August 0.00 0.00 01-AUG-00:10 27.32 18.12 0.00 0.00 01-AUG-00:10 27.32 18.12
September 0.00 0.00 01-SEP-00:10 22.63 17.18 0.00 0.00 01-SEP-00:10 22.63 17.18
October 0.00 0.00 01-OCT-00:10 16.02 8.67 0.00 0.00 01-OCT-00:10 16.02 8.67
November 0.00 0.00 01-NOV-00:10 10.60 5.64 0.00 0.00 01-NOV-00:10 10.60 5.64
December 0.00 0.00 01-DEC-00:10 8.95 5.46 0.00 0.00 01-DEC-00:10 8.95 5.46
                     
Annual Sum or Average 0.00         0.00        
Minimum of Months 0.00 0.00   6.42 1.84 0.00 0.00   6.42 1.84
Maximum of Months 0.00 0.00   27.63 18.12 0.00 0.00   27.63 18.12



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 8777286.00 5504.64 30-JAN-07:01 -1.0
February 7395982.63 5175.84 03-FEB-08:62 -2.0
March 16071921.20 4249.51 02-MAR-08:62 -0.9
April 24278679.07 742.25 19-APR-16:03 31.10
May 44234424.36 954.68 19-MAY-16:03 34.90
June 67280756.55 1207.58 02-JUN-17:02 38.62
July 53955760.28 1146.49 03-JUL-17:02 38.12
August 48483059.24 1043.17 07-AUG-17:01 36.32
September 38216265.42 855.03 19-SEP-17:01 33.03
October 13060359.94 695.92 04-OCT-16:02 30.60
November 976239.86 262.03 03-NOV-16:02 23.35
December 8355928.55 5728.66 05-DEC-08:62 2.07
         
Annual Sum or Average 0.331087E+09      
Minimum of Months 976239.86 262.03   -2.0
Maximum of Months 67280756.55 5728.66   38.62



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.231400E+09 8410.62 09-JAN-07:01 3.98
February 0.181932E+09 8172.82 09-FEB-07:02 0.78
March 0.205161E+09 8324.95 29-MAR-06:02 1.38
April 60997222.62 6031.79 13-APR-07:01 8.68
May 60422284.05 799.64 19-MAY-17:02 34.22
June 74077001.52 991.09 02-JUN-17:23 38.05
July 59851524.18 945.79 03-JUL-17:23 37.75
August 54797601.09 850.14 04-AUG-17:22 35.60
September 37499933.45 709.91 20-SEP-17:11 32.43
October 15540074.43 532.48 04-OCT-17:02 30.22
November 44502720.56 7887.49 28-NOV-07:02 0.87
December 0.244922E+09 7895.04 29-DEC-07:01 -0.6
         
Annual Sum or Average 0.127110E+10      
Minimum of Months 15540074.43 532.48   -0.6
Maximum of Months 0.244922E+09 8410.62   38.05



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.128692E+09 6280.14 09-JAN-07:01 3.98
February 85587683.50 5361.58 15-FEB-07:02 1.57
March 75582405.55 5487.47 01-MAR-07:02 1.28
April 25259831.10 453.91 19-APR-17:23 30.55
May 35129323.19 530.42 19-MAY-17:22 33.85
June 45875171.86 644.28 02-JUN-17:23 38.05
July 37387422.02 618.62 03-JUL-17:23 37.75
August 36511195.01 566.56 07-AUG-17:12 35.93
September 27082009.58 483.00 20-SEP-17:11 32.43
October 15803994.24 398.81 04-OCT-17:02 30.22
November 15129380.51 5272.12 28-NOV-07:02 0.87
December 0.113647E+09 5456.85 21-DEC-07:02 0.60
         
Annual Sum or Average 0.641688E+09      
Minimum of Months 15129380.51 398.81   0.60
Maximum of Months 0.128692E+09 6280.14   38.05



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.412071E+09 8604.58 09-JAN-07:01 3.98
February 0.313973E+09 8017.78 09-FEB-07:02 0.78
March 0.247000E+09 8154.69 29-MAR-06:02 1.38
April 42973710.96 4351.83 12-APR-07:02 7.35
May 50922252.49 801.60 19-MAY-17:02 34.22
June 66571451.54 991.82 02-JUN-17:23 38.05
July 55172411.29 949.06 03-JUL-17:23 37.75
August 51084425.13 868.67 07-AUG-17:12 35.93
September 38451912.46 737.43 19-SEP-17:01 33.03
October 20994779.08 608.86 04-OCT-17:02 30.22
November 40580146.97 7729.15 28-NOV-07:02 0.87
December 0.356110E+09 8249.81 18-DEC-07:02 2.80
         
Annual Sum or Average 0.169591E+10      
Minimum of Months 20994779.08 608.86   0.78
Maximum of Months 0.412071E+09 8604.58   38.05



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.182868E+09 7315.54 09-JAN-07:01 3.98
February 0.159713E+09 5938.30 15-FEB-07:02 1.57
March 0.128636E+09 6081.88 01-MAR-07:02 1.28
April 33445553.47 479.39 19-APR-17:23 30.55
May 40253960.97 546.91 19-MAY-17:22 33.85
June 37971037.61 700.50 02-JUN-17:23 38.05
July 29122134.62 686.74 03-JUL-17:23 37.75
August 30470837.88 584.55 07-AUG-17:12 35.93
September 22806030.68 499.42 20-SEP-17:11 32.43
October 18079288.88 398.60 04-OCT-17:32 29.07
November 24409481.33 5136.97 28-NOV-07:02 0.87
December 0.162558E+09 5857.97 29-DEC-07:01 -0.6
         
Annual Sum or Average 0.870333E+09      
Minimum of Months 18079288.88 398.60   -0.6
Maximum of Months 0.182868E+09 7315.54   38.05



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: ATTIC

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.00 0.00 01-JAN-00:10 6.70
February 0.00 0.00 01-FEB-00:10 6.42
March 0.00 0.00 01-MAR-00:10 7.32
April 0.00 0.00 01-APR-00:10 11.18
May 0.00 0.00 01-MAY-00:10 20.40
June 0.00 0.00 01-JUN-00:10 25.03
July 0.00 0.00 01-JUL-00:10 27.63
August 0.00 0.00 01-AUG-00:10 27.32
September 0.00 0.00 01-SEP-00:10 22.63
October 0.00 0.00 01-OCT-00:10 16.02
November 0.00 0.00 01-NOV-00:10 10.60
December 0.00 0.00 01-DEC-00:10 8.95
         
Annual Sum or Average 0.00      
Minimum of Months 0.00 0.00   6.42
Maximum of Months 0.00 0.00   27.63



Table of Contents

Report: ZoneElectricSummaryMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.714248E+09 593.08 02-JAN-08:09 0.118664E+10 973.59 02-JAN-08:09
February 0.645736E+09 593.08 01-FEB-08:09 0.107295E+10 973.59 01-FEB-08:09
March 0.752015E+09 593.08 01-MAR-08:09 0.125726E+10 973.59 01-MAR-08:09
April 0.685116E+09 593.08 03-APR-07:10 0.113787E+10 973.59 03-APR-07:10
May 0.733131E+09 593.08 01-MAY-07:10 0.122195E+10 973.59 01-MAY-07:10
June 0.722883E+09 593.08 01-JUN-07:10 0.120670E+10 973.59 01-JUN-07:10
July 0.695364E+09 593.08 03-JUL-07:10 0.115223E+10 973.59 03-JUL-07:10
August 0.752015E+09 593.08 01-AUG-07:10 0.125726E+10 973.59 01-AUG-07:10
September 0.685116E+09 593.08 01-SEP-07:10 0.113608E+10 973.59 01-SEP-07:10
October 0.714248E+09 593.08 02-OCT-07:10 0.118754E+10 973.59 02-OCT-07:10
November 0.704000E+09 593.08 01-NOV-07:10 0.117228E+10 973.59 01-NOV-07:10
December 0.695364E+09 593.08 01-DEC-08:09 0.115133E+10 973.59 01-DEC-08:09
             
Annual Sum or Average 0.849924E+10     0.141401E+11    
Minimum of Months 0.645736E+09 593.08   0.107295E+10 973.59  
Maximum of Months 0.752015E+09 593.08   0.125726E+10 973.59  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.454401E+09 445.37 17-JAN-16:00 0.899552E+09 738.04 02-JAN-08:09
February 0.413195E+09 436.38 23-FEB-16:00 0.813362E+09 738.04 01-FEB-08:09
March 0.474112E+09 436.38 10-MAR-16:00 0.953087E+09 738.04 01-MAR-08:09
April 0.435054E+09 424.33 20-APR-07:10 0.862580E+09 738.04 03-APR-07:10
May 0.474405E+09 407.04 03-MAY-07:10 0.926320E+09 738.04 01-MAY-07:10
June 0.473849E+09 392.87 26-JUN-07:10 0.914754E+09 738.04 01-JUN-07:10
July 0.454602E+09 424.33 07-JUL-07:30 0.873466E+09 738.04 03-JUL-07:10
August 0.483308E+09 422.93 17-AUG-07:10 0.953087E+09 738.04 01-AUG-07:10
September 0.435305E+09 411.31 18-SEP-07:10 0.861220E+09 738.04 01-SEP-07:10
October 0.449828E+09 440.62 13-OCT-07:10 0.900233E+09 738.04 02-OCT-07:10
November 0.447787E+09 449.59 22-NOV-16:00 0.888667E+09 738.04 01-NOV-07:10
December 0.445057E+09 449.59 01-DEC-16:00 0.872785E+09 738.04 01-DEC-08:09
             
Annual Sum or Average 0.544091E+10     0.107191E+11    
Minimum of Months 0.413195E+09 392.87   0.813362E+09 738.04  
Maximum of Months 0.483308E+09 449.59   0.953087E+09 738.04  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.288190E+09 264.56 17-JAN-16:00 0.533626E+09 437.82 02-JAN-08:09
February 0.258667E+09 261.14 13-FEB-16:00 0.482497E+09 437.82 01-FEB-08:09
March 0.293962E+09 260.21 10-MAR-16:00 0.565383E+09 437.82 01-MAR-08:09
April 0.265967E+09 250.13 20-APR-07:10 0.511694E+09 437.82 03-APR-07:10
May 0.283606E+09 245.93 24-MAY-15:39 0.549505E+09 437.82 01-MAY-07:10
June 0.279555E+09 242.83 19-JUN-15:20 0.542644E+09 437.82 01-JUN-07:10
July 0.270319E+09 250.23 07-JUL-07:30 0.518151E+09 437.82 03-JUL-07:10
August 0.292472E+09 251.24 16-AUG-15:00 0.565383E+09 437.82 01-AUG-07:10
September 0.268489E+09 250.44 29-SEP-15:00 0.510887E+09 437.82 01-SEP-07:10
October 0.283706E+09 261.48 13-OCT-07:10 0.534030E+09 437.82 02-OCT-07:10
November 0.284737E+09 266.70 22-NOV-16:00 0.527169E+09 437.82 01-NOV-07:10
December 0.280980E+09 266.70 01-DEC-16:00 0.517747E+09 437.82 01-DEC-08:09
             
Annual Sum or Average 0.335065E+10     0.635872E+10    
Minimum of Months 0.258667E+09 242.83   0.482497E+09 437.82  
Maximum of Months 0.293962E+09 266.70   0.565383E+09 437.82  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.513478E+09 445.93 17-JAN-16:00 0.899552E+09 738.04 02-JAN-08:09
February 0.458947E+09 438.45 23-FEB-16:00 0.813362E+09 738.04 01-FEB-08:09
March 0.522295E+09 437.84 10-MAR-16:00 0.953087E+09 738.04 01-MAR-08:09
April 0.465504E+09 426.48 20-APR-07:10 0.862580E+09 738.04 03-APR-07:10
May 0.485570E+09 413.33 23-MAY-12:39 0.926320E+09 738.04 01-MAY-07:10
June 0.475448E+09 397.57 26-JUN-10:30 0.914754E+09 738.04 01-JUN-07:10
July 0.460575E+09 425.01 07-JUL-07:30 0.873466E+09 738.04 03-JUL-07:10
August 0.505953E+09 424.11 17-AUG-07:19 0.953087E+09 738.04 01-AUG-07:10
September 0.475261E+09 424.22 29-SEP-07:10 0.861220E+09 738.04 01-SEP-07:10
October 0.503645E+09 441.64 13-OCT-07:10 0.900233E+09 738.04 02-OCT-07:10
November 0.505464E+09 449.59 22-NOV-16:00 0.888667E+09 738.04 01-NOV-07:10
December 0.500672E+09 449.59 01-DEC-16:00 0.872785E+09 738.04 01-DEC-08:09
             
Annual Sum or Average 0.587281E+10     0.107191E+11    
Minimum of Months 0.458947E+09 397.57   0.813362E+09 738.04  
Maximum of Months 0.522295E+09 449.59   0.953087E+09 738.04  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.286822E+09 264.29 17-JAN-16:00 0.533626E+09 437.82 02-JAN-08:09
February 0.258650E+09 259.19 13-FEB-08:09 0.482497E+09 437.82 01-FEB-08:09
March 0.295392E+09 258.79 10-MAR-16:00 0.565383E+09 437.82 01-MAR-08:09
April 0.267215E+09 254.91 20-APR-07:10 0.511694E+09 437.82 03-APR-07:10
May 0.284123E+09 248.44 03-MAY-07:10 0.549505E+09 437.82 01-MAY-07:10
June 0.280501E+09 244.64 26-JUN-07:10 0.542644E+09 437.82 01-JUN-07:10
July 0.271295E+09 254.02 07-JUL-07:30 0.518151E+09 437.82 03-JUL-07:10
August 0.293643E+09 254.38 17-AUG-07:10 0.565383E+09 437.82 01-AUG-07:10
September 0.269083E+09 254.34 18-SEP-07:10 0.510887E+09 437.82 01-SEP-07:10
October 0.282629E+09 262.07 13-OCT-07:10 0.534030E+09 437.82 02-OCT-07:10
November 0.282737E+09 266.70 22-NOV-16:00 0.527169E+09 437.82 01-NOV-07:10
December 0.280782E+09 266.70 01-DEC-16:00 0.517747E+09 437.82 01-DEC-08:09
             
Annual Sum or Average 0.335287E+10     0.635872E+10    
Minimum of Months 0.258650E+09 244.64   0.482497E+09 437.82  
Maximum of Months 0.295392E+09 266.70   0.565383E+09 437.82  



Table of Contents

Report: SpaceGainsMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 0.711734E+09 0.714248E+09 0.118664E+10 0.00 0.00 0.00 0.00 0.00 0.00
February 0.643949E+09 0.645736E+09 0.107295E+10 0.00 0.00 0.00 0.00 0.00 0.00
March 0.779518E+09 0.752015E+09 0.125726E+10 0.00 0.00 0.00 0.00 0.00 0.00
April 0.677841E+09 0.685116E+09 0.113787E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.745626E+09 0.733131E+09 0.122195E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.745626E+09 0.722883E+09 0.120670E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.677841E+09 0.695364E+09 0.115223E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.779518E+09 0.752015E+09 0.125726E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.677841E+09 0.685116E+09 0.113608E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.711734E+09 0.714248E+09 0.118754E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 0.711734E+09 0.704000E+09 0.117228E+10 0.00 0.00 0.00 0.00 0.00 0.00
December 0.677841E+09 0.695364E+09 0.115133E+10 0.00 0.00 0.00 0.00 0.00 0.00
                   
Annual Sum or Average 0.854080E+10 0.849924E+10 0.141401E+11 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.643949E+09 0.645736E+09 0.107295E+10 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.779518E+09 0.752015E+09 0.125726E+10 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SpaceGainsMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.539540E+09 0.454401E+09 0.899552E+09 0.00 0.00 0.00 0.00 0.00 0.663455E+09
February 0.488155E+09 0.413195E+09 0.813362E+09 0.00 0.00 0.00 0.00 0.00 0.532606E+09
March 0.590925E+09 0.474112E+09 0.953087E+09 0.00 0.00 0.00 0.00 347316.50 0.493292E+09
April 0.513848E+09 0.435054E+09 0.862580E+09 0.00 0.00 0.00 0.00 44277895.12 0.225520E+09
May 0.565233E+09 0.474405E+09 0.926320E+09 0.00 0.00 0.00 0.00 0.127597E+09 0.110901E+09
June 0.565233E+09 0.473849E+09 0.914754E+09 0.00 0.00 0.00 0.00 0.266217E+09 56335028.38
July 0.513848E+09 0.454602E+09 0.873466E+09 0.00 0.00 0.00 0.00 0.212500E+09 43443266.29
August 0.590925E+09 0.483308E+09 0.953087E+09 0.00 0.00 0.00 0.00 0.179682E+09 80906561.34
September 0.513848E+09 0.435305E+09 0.861220E+09 0.00 0.00 0.00 0.00 0.123588E+09 0.109759E+09
October 0.539540E+09 0.449828E+09 0.900233E+09 0.00 0.00 0.00 0.00 25293600.34 0.271804E+09
November 0.539540E+09 0.447787E+09 0.888667E+09 0.00 0.00 0.00 0.00 239.31 0.518476E+09
December 0.513848E+09 0.445057E+09 0.872785E+09 0.00 0.00 0.00 0.00 0.00 0.702927E+09
                   
Annual Sum or Average 0.647448E+10 0.544091E+10 0.107191E+11 0.00 0.00 0.00 0.00 0.979503E+09 0.380942E+10
Minimum of Months 0.488155E+09 0.413195E+09 0.813362E+09 0.00 0.00 0.00 0.00 0.00 43443266.29
Maximum of Months 0.590925E+09 0.483308E+09 0.953087E+09 0.00 0.00 0.00 0.00 0.266217E+09 0.702927E+09



Table of Contents

Report: SpaceGainsMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.234287E+09 0.288190E+09 0.533626E+09 0.00 0.00 0.00 0.00 0.00 35385195.94
February 0.211974E+09 0.258667E+09 0.482497E+09 0.00 0.00 0.00 0.00 24058.27 30856102.59
March 0.256600E+09 0.293962E+09 0.565383E+09 0.00 0.00 0.00 0.00 25046.03 31278941.48
April 0.223130E+09 0.265967E+09 0.511694E+09 0.00 0.00 0.00 0.00 1628049.51 19131947.90
May 0.245443E+09 0.283606E+09 0.549505E+09 0.00 0.00 0.00 0.00 3814030.62 12202278.80
June 0.245443E+09 0.279555E+09 0.542644E+09 0.00 0.00 0.00 0.00 6444501.24 5898857.68
July 0.223130E+09 0.270319E+09 0.518151E+09 0.00 0.00 0.00 0.00 4164759.95 5546334.37
August 0.256600E+09 0.292472E+09 0.565383E+09 0.00 0.00 0.00 0.00 3225209.52 6858444.25
September 0.223130E+09 0.268489E+09 0.510887E+09 0.00 0.00 0.00 0.00 854967.87 8133661.46
October 0.234287E+09 0.283706E+09 0.534030E+09 0.00 0.00 0.00 0.00 317954.04 20337127.13
November 0.234287E+09 0.284737E+09 0.527169E+09 0.00 0.00 0.00 0.00 6.79 33422834.27
December 0.223130E+09 0.280980E+09 0.517747E+09 0.00 0.00 0.00 0.00 0.00 32184225.44
                   
Annual Sum or Average 0.281144E+10 0.335065E+10 0.635872E+10 0.00 0.00 0.00 0.00 20498583.84 0.241236E+09
Minimum of Months 0.211974E+09 0.258667E+09 0.482497E+09 0.00 0.00 0.00 0.00 0.00 5546334.37
Maximum of Months 0.256600E+09 0.293962E+09 0.565383E+09 0.00 0.00 0.00 0.00 6444501.24 35385195.94



Table of Contents

Report: SpaceGainsMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.539540E+09 0.513478E+09 0.899552E+09 0.00 0.00 0.00 0.00 0.00 50503369.59
February 0.488155E+09 0.458947E+09 0.813362E+09 0.00 0.00 0.00 0.00 341235.54 43440267.53
March 0.590925E+09 0.522295E+09 0.953087E+09 0.00 0.00 0.00 0.00 269605.39 43418260.59
April 0.513848E+09 0.465504E+09 0.862580E+09 0.00 0.00 0.00 0.00 3473061.15 26342882.40
May 0.565233E+09 0.485570E+09 0.926320E+09 0.00 0.00 0.00 0.00 6743550.40 16746383.58
June 0.565233E+09 0.475448E+09 0.914754E+09 0.00 0.00 0.00 0.00 10476264.12 8063976.92
July 0.513848E+09 0.460575E+09 0.873466E+09 0.00 0.00 0.00 0.00 6780101.50 7492888.82
August 0.590925E+09 0.505953E+09 0.953087E+09 0.00 0.00 0.00 0.00 5444175.81 9441594.50
September 0.513848E+09 0.475261E+09 0.861220E+09 0.00 0.00 0.00 0.00 1518881.18 10942014.89
October 0.539540E+09 0.503645E+09 0.900233E+09 0.00 0.00 0.00 0.00 651152.05 28567215.26
November 0.539540E+09 0.505464E+09 0.888667E+09 0.00 0.00 0.00 0.00 10.16 47246970.52
December 0.513848E+09 0.500672E+09 0.872785E+09 0.00 0.00 0.00 0.00 0.00 45881284.76
                   
Annual Sum or Average 0.647448E+10 0.587281E+10 0.107191E+11 0.00 0.00 0.00 0.00 35698037.30 0.338087E+09
Minimum of Months 0.488155E+09 0.458947E+09 0.813362E+09 0.00 0.00 0.00 0.00 0.00 7492888.82
Maximum of Months 0.590925E+09 0.522295E+09 0.953087E+09 0.00 0.00 0.00 0.00 10476264.12 50503369.59



Table of Contents

Report: SpaceGainsMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.320062E+09 0.286822E+09 0.533626E+09 0.00 0.00 0.00 0.00 0.00 36234599.20
February 0.289580E+09 0.258650E+09 0.482497E+09 0.00 0.00 0.00 0.00 34532.04 31232662.96
March 0.350544E+09 0.295392E+09 0.565383E+09 0.00 0.00 0.00 0.00 47149.37 32285454.02
April 0.304821E+09 0.267215E+09 0.511694E+09 0.00 0.00 0.00 0.00 1454361.51 20088015.67
May 0.335303E+09 0.284123E+09 0.549505E+09 0.00 0.00 0.00 0.00 3134610.83 13425467.62
June 0.335303E+09 0.280501E+09 0.542644E+09 0.00 0.00 0.00 0.00 5880989.06 6482586.74
July 0.304821E+09 0.271295E+09 0.518151E+09 0.00 0.00 0.00 0.00 3787141.81 6010055.25
August 0.350544E+09 0.293643E+09 0.565383E+09 0.00 0.00 0.00 0.00 2945079.45 7320159.78
September 0.304821E+09 0.269083E+09 0.510887E+09 0.00 0.00 0.00 0.00 852949.39 8550563.96
October 0.320062E+09 0.282629E+09 0.534030E+09 0.00 0.00 0.00 0.00 305658.48 21486136.06
November 0.320062E+09 0.282737E+09 0.527169E+09 0.00 0.00 0.00 0.00 6.77 34135795.92
December 0.304821E+09 0.280782E+09 0.517747E+09 0.00 0.00 0.00 0.00 0.00 32655430.60
                   
Annual Sum or Average 0.384075E+10 0.335287E+10 0.635872E+10 0.00 0.00 0.00 0.00 18442478.70 0.249907E+09
Minimum of Months 0.289580E+09 0.258650E+09 0.482497E+09 0.00 0.00 0.00 0.00 0.00 6010055.25
Maximum of Months 0.350544E+09 0.295392E+09 0.565383E+09 0.00 0.00 0.00 0.00 5880989.06 36234599.20



Table of Contents

Report: SpaceGainsMonthly

For: ATTIC

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [] ZONE LIGHTS TOTAL HEATING ENERGY [] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.112595E+10 0.233813E+10
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.106823E+10 0.255376E+10
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.111828E+10 0.358887E+10
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.107766E+10 0.419501E+10
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.107488E+10 0.456625E+10
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.883406E+09 0.468747E+10
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.677406E+09 0.454355E+10
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.781113E+09 0.426210E+10
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.916303E+09 0.388762E+10
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.987363E+09 0.314202E+10
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.116003E+10 0.254876E+10
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.138675E+10 0.220283E+10
                   
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.122574E+11 0.425164E+11
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.677406E+09 0.220283E+10
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.138675E+10 0.468747E+10



Table of Contents

Report: PeakSpaceGainsMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 966.54 02-JAN-08:09 593.08 02-JAN-08:09 973.59 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 0.00
February 966.54 01-FEB-08:09 593.08 01-FEB-08:09 973.59 01-FEB-08:09 0.00 0.00 0.00 0.00 0.00 0.00
March 966.54 01-MAR-08:09 593.08 01-MAR-08:09 973.59 01-MAR-08:09 0.00 0.00 0.00 0.00 0.00 0.00
April 966.54 03-APR-07:10 593.08 03-APR-07:10 973.59 03-APR-07:10 0.00 0.00 0.00 0.00 0.00 0.00
May 966.54 01-MAY-07:10 593.08 01-MAY-07:10 973.59 01-MAY-07:10 0.00 0.00 0.00 0.00 0.00 0.00
June 966.54 01-JUN-07:10 593.08 01-JUN-07:10 973.59 01-JUN-07:10 0.00 0.00 0.00 0.00 0.00 0.00
July 966.54 03-JUL-07:10 593.08 03-JUL-07:10 973.59 03-JUL-07:10 0.00 0.00 0.00 0.00 0.00 0.00
August 966.54 01-AUG-07:10 593.08 01-AUG-07:10 973.59 01-AUG-07:10 0.00 0.00 0.00 0.00 0.00 0.00
September 966.54 01-SEP-07:10 593.08 01-SEP-07:10 973.59 01-SEP-07:10 0.00 0.00 0.00 0.00 0.00 0.00
October 966.54 02-OCT-07:10 593.08 02-OCT-07:10 973.59 02-OCT-07:10 0.00 0.00 0.00 0.00 0.00 0.00
November 966.54 01-NOV-07:10 593.08 01-NOV-07:10 973.59 01-NOV-07:10 0.00 0.00 0.00 0.00 0.00 0.00
December 966.54 01-DEC-08:09 593.08 01-DEC-08:09 973.59 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average             0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 966.54   593.08   973.59   0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 966.54   593.08   973.59   0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: PeakSpaceGainsMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 732.70 02-JAN-08:09 445.37 17-JAN-16:00 738.04 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 3643.24 27-JAN-07:10
February 732.70 01-FEB-08:09 436.38 23-FEB-16:00 738.04 01-FEB-08:09 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 3762.89 03-FEB-07:10
March 732.70 01-MAR-08:09 436.38 10-MAR-16:00 738.04 01-MAR-08:09 0.00 0.00 0.00 0.00 94.70 21-MAR-16:03 3232.67 02-MAR-07:10
April 732.70 03-APR-07:10 424.33 20-APR-07:10 738.04 03-APR-07:10 0.00 0.00 0.00 0.00 896.89 19-APR-12:00 2322.44 12-APR-06:10
May 732.70 01-MAY-07:10 407.04 03-MAY-07:10 738.04 01-MAY-07:10 0.00 0.00 0.00 0.00 1336.25 19-MAY-16:03 1752.56 02-MAY-06:03
June 732.70 01-JUN-07:10 392.87 26-JUN-07:10 738.04 01-JUN-07:10 0.00 0.00 0.00 0.00 1809.04 02-JUN-16:03 1164.66 13-JUN-06:03
July 732.70 03-JUL-07:10 424.33 07-JUL-07:30 738.04 03-JUL-07:10 0.00 0.00 0.00 0.00 1721.48 03-JUL-16:02 1135.50 05-JUL-06:01
August 732.70 01-AUG-07:10 422.93 17-AUG-07:10 738.04 01-AUG-07:10 0.00 0.00 0.00 0.00 1579.84 07-AUG-16:03 1233.37 14-AUG-06:01
September 732.70 01-SEP-07:10 411.31 18-SEP-07:10 738.04 01-SEP-07:10 0.00 0.00 0.00 0.00 1158.18 19-SEP-16:03 2025.84 25-SEP-06:03
October 732.70 02-OCT-07:10 440.62 13-OCT-07:10 738.04 02-OCT-07:10 0.00 0.00 0.00 0.00 755.54 05-OCT-16:03 2324.52 11-OCT-06:03
November 732.70 01-NOV-07:10 449.59 22-NOV-16:00 738.04 01-NOV-07:10 0.00 0.00 0.00 0.00 0.20 08-NOV-14:53 2913.14 17-NOV-07:03
December 732.70 01-DEC-08:09 449.59 01-DEC-16:00 738.04 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 3650.45 27-DEC-07:10
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 732.70   392.87   738.04   0.00 0.00 0.00 0.00 0.00   1135.50  
Maximum of Months 732.70   449.59   738.04   0.00 0.00 0.00 0.00 1809.04   3762.89  



Table of Contents

Report: PeakSpaceGainsMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 434.65 02-JAN-08:09 264.56 17-JAN-16:00 437.82 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 83.78 25-JAN-23:00
February 434.65 01-FEB-08:09 261.14 13-FEB-16:00 437.82 01-FEB-08:09 0.00 0.00 0.00 0.00 2.60 20-FEB-16:00 116.30 08-FEB-21:00
March 434.65 01-MAR-08:09 260.21 10-MAR-16:00 437.82 01-MAR-08:09 0.00 0.00 0.00 0.00 2.55 19-MAR-14:53 79.38 19-MAR-24:00
April 434.65 03-APR-07:10 250.13 20-APR-07:10 437.82 03-APR-07:10 0.00 0.00 0.00 0.00 19.94 21-APR-18:10 93.67 10-APR-24:00
May 434.65 01-MAY-07:10 245.93 24-MAY-15:39 437.82 01-MAY-07:10 0.00 0.00 0.00 0.00 22.07 19-MAY-18:10 43.26 04-MAY-02:00
June 434.65 01-JUN-07:10 242.83 19-JUN-15:20 437.82 01-JUN-07:10 0.00 0.00 0.00 0.00 26.20 07-JUN-19:00 38.66 28-JUN-02:00
July 434.65 03-JUL-07:10 250.23 07-JUL-07:30 437.82 03-JUL-07:10 0.00 0.00 0.00 0.00 19.35 02-JUL-17:52 29.22 04-JUL-18:55
August 434.65 01-AUG-07:10 251.24 16-AUG-15:00 437.82 01-AUG-07:10 0.00 0.00 0.00 0.00 17.29 07-AUG-18:10 39.49 14-AUG-00:55
September 434.65 01-SEP-07:10 250.44 29-SEP-15:00 437.82 01-SEP-07:10 0.00 0.00 0.00 0.00 5.59 17-SEP-15:55 24.16 23-SEP-17:03
October 434.65 02-OCT-07:10 261.48 13-OCT-07:10 437.82 02-OCT-07:10 0.00 0.00 0.00 0.00 9.35 01-OCT-14:53 52.52 23-OCT-18:03
November 434.65 01-NOV-07:10 266.70 22-NOV-16:00 437.82 01-NOV-07:10 0.00 0.00 0.00 0.00 0.01 03-NOV-15:53 62.68 10-NOV-07:00
December 434.65 01-DEC-08:09 266.70 01-DEC-16:00 437.82 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 72.89 18-DEC-06:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 434.65   242.83   437.82   0.00 0.00 0.00 0.00 0.00   24.16  
Maximum of Months 434.65   266.70   437.82   0.00 0.00 0.00 0.00 26.20   116.30  



Table of Contents

Report: PeakSpaceGainsMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 732.70 02-JAN-08:09 445.93 17-JAN-16:00 738.04 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 124.24 25-JAN-23:00
February 732.70 01-FEB-08:09 438.45 23-FEB-16:00 738.04 01-FEB-08:09 0.00 0.00 0.00 0.00 12.92 20-FEB-15:53 167.64 08-FEB-21:00
March 732.70 01-MAR-08:09 437.84 10-MAR-16:00 738.04 01-MAR-08:09 0.00 0.00 0.00 0.00 14.55 19-MAR-14:53 110.44 19-MAR-24:00
April 732.70 03-APR-07:10 426.48 20-APR-07:10 738.04 03-APR-07:10 0.00 0.00 0.00 0.00 35.54 02-APR-14:00 137.55 10-APR-24:00
May 732.70 01-MAY-07:10 413.33 23-MAY-12:39 738.04 01-MAY-07:10 0.00 0.00 0.00 0.00 37.57 14-MAY-15:53 64.71 04-MAY-02:00
June 732.70 01-JUN-07:10 397.57 26-JUN-10:30 738.04 01-JUN-07:10 0.00 0.00 0.00 0.00 41.53 07-JUN-19:00 57.56 28-JUN-02:00
July 732.70 03-JUL-07:10 425.01 07-JUL-07:30 738.04 03-JUL-07:10 0.00 0.00 0.00 0.00 30.00 02-JUL-21:40 40.20 04-JUL-18:55
August 732.70 01-AUG-07:10 424.11 17-AUG-07:19 738.04 01-AUG-07:10 0.00 0.00 0.00 0.00 26.49 07-AUG-18:10 56.30 14-AUG-00:55
September 732.70 01-SEP-07:10 424.22 29-SEP-07:10 738.04 01-SEP-07:10 0.00 0.00 0.00 0.00 9.26 17-SEP-15:53 33.65 23-SEP-17:03
October 732.70 02-OCT-07:10 441.64 13-OCT-07:10 738.04 02-OCT-07:10 0.00 0.00 0.00 0.00 20.50 01-OCT-14:53 74.89 23-OCT-18:10
November 732.70 01-NOV-07:10 449.59 22-NOV-16:00 738.04 01-NOV-07:10 0.00 0.00 0.00 0.00 0.01 03-NOV-16:00 84.67 10-NOV-07:00
December 732.70 01-DEC-08:09 449.59 01-DEC-16:00 738.04 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 104.27 18-DEC-06:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 732.70   397.57   738.04   0.00 0.00 0.00 0.00 0.00   33.65  
Maximum of Months 732.70   449.59   738.04   0.00 0.00 0.00 0.00 41.53   167.64  



Table of Contents

Report: PeakSpaceGainsMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 434.65 02-JAN-08:09 264.29 17-JAN-16:00 437.82 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 84.40 25-JAN-23:00
February 434.65 01-FEB-08:09 259.19 13-FEB-08:09 437.82 01-FEB-08:09 0.00 0.00 0.00 0.00 3.07 19-FEB-14:00 118.41 08-FEB-21:00
March 434.65 01-MAR-08:09 258.79 10-MAR-16:00 437.82 01-MAR-08:09 0.00 0.00 0.00 0.00 4.40 19-MAR-14:05 79.96 19-MAR-24:00
April 434.65 03-APR-07:10 254.91 20-APR-07:10 437.82 03-APR-07:10 0.00 0.00 0.00 0.00 17.67 02-APR-14:00 93.93 10-APR-24:00
May 434.65 01-MAY-07:10 248.44 03-MAY-07:10 437.82 01-MAY-07:10 0.00 0.00 0.00 0.00 17.37 14-MAY-14:55 45.29 04-MAY-02:00
June 434.65 01-JUN-07:10 244.64 26-JUN-07:10 437.82 01-JUN-07:10 0.00 0.00 0.00 0.00 23.03 07-JUN-19:00 41.26 28-JUN-02:00
July 434.65 03-JUL-07:10 254.02 07-JUL-07:30 437.82 03-JUL-07:10 0.00 0.00 0.00 0.00 20.64 02-JUL-21:25 30.79 04-JUL-18:55
August 434.65 01-AUG-07:10 254.38 17-AUG-07:10 437.82 01-AUG-07:10 0.00 0.00 0.00 0.00 16.40 07-AUG-18:10 40.00 14-AUG-00:55
September 434.65 01-SEP-07:10 254.34 18-SEP-07:10 437.82 01-SEP-07:10 0.00 0.00 0.00 0.00 5.28 17-SEP-16:00 24.04 23-SEP-17:03
October 434.65 02-OCT-07:10 262.07 13-OCT-07:10 437.82 02-OCT-07:10 0.00 0.00 0.00 0.00 8.00 01-OCT-14:53 58.20 23-OCT-18:03
November 434.65 01-NOV-07:10 266.70 22-NOV-16:00 437.82 01-NOV-07:10 0.00 0.00 0.00 0.00 0.01 03-NOV-16:00 62.47 10-NOV-07:00
December 434.65 01-DEC-08:09 266.70 01-DEC-16:00 437.82 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 73.76 18-DEC-06:00
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 434.65   244.64   437.82   0.00 0.00 0.00 0.00 0.00   24.04  
Maximum of Months 434.65   266.70   437.82   0.00 0.00 0.00 0.00 23.03   118.41  



Table of Contents

Report: PeakSpaceGainsMonthly

For: ATTIC

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [] ZONE LIGHTS TOTAL HEATING ENERGY [] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1663.99 03-JAN-08:62 4688.02 26-JAN-13:00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1775.55 10-FEB-24:00 5638.47 09-FEB-12:20
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1834.81 31-MAR-04:55 6328.88 17-MAR-12:50
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1619.83 27-APR-05:40 6713.24 13-APR-13:50
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1570.16 21-MAY-02:00 6308.40 12-MAY-12:30
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1867.20 14-JUN-03:55 6555.73 29-JUN-12:20
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1418.40 01-JUL-05:40 6204.50 06-JUL-13:10
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1427.77 26-AUG-06:00 6185.39 03-AUG-12:30
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1478.90 20-SEP-06:42 6318.87 05-SEP-13:00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1515.63 30-OCT-22:00 5849.19 24-OCT-13:50
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1759.07 23-NOV-01:00 5144.68 07-NOV-12:10
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2629.59 20-DEC-03:53 5127.55 27-DEC-13:10
                       
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00        
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1418.40   4688.02  
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2629.59   6713.24  



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 1481.65 27-JAN-08:05 3866.15 2372.30 3894.35 0.00 0.00 0.00 0.00 0.00 0.00
February 1380.22 03-FEB-08:05 3866.15 2372.30 3894.35 0.00 0.00 0.00 0.00 0.00 0.00
March 1700.64 16-MAR-15:55 3866.15 2372.30 3894.35 0.00 0.00 0.00 0.00 0.00 0.00
April 5702.12 24-APR-07:02 5799.23 3558.46 5841.53 0.00 0.00 0.00 0.00 0.00 0.00
May 5791.85 02-MAY-07:02 5799.23 3558.46 5841.53 0.00 0.00 0.00 0.00 0.00 0.00
June 5854.02 12-JUN-06:01 1420.81 1937.36 3407.56 0.00 0.00 0.00 0.00 0.00 0.00
July 5413.29 03-JUL-05:02 531.60 757.81 2433.97 0.00 0.00 0.00 0.00 0.00 0.00
August 5623.13 23-AUG-06:02 1014.87 1383.83 2433.97 0.00 0.00 0.00 0.00 0.00 0.00
September 5615.59 11-SEP-06:01 1420.81 1937.36 3407.56 0.00 0.00 0.00 0.00 0.00 0.00
October 5909.94 31-OCT-07:02 4832.69 2965.38 4867.94 0.00 0.00 0.00 0.00 0.00 0.00
November 5618.73 09-NOV-08:62 4832.69 2965.38 4867.94 0.00 0.00 0.00 0.00 0.00 0.00
December 1401.10 27-DEC-08:05 3866.15 2372.30 3894.35 0.00 0.00 0.00 0.00 0.00 0.00
                       
Annual Sum or Average           0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 1380.22   531.60 757.81 2433.97 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 5909.94   5799.23 3558.46 5841.53 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 2831.55 12-JAN-14:55 1465.40 656.31 1476.09 0.00 0.00 0.00 0.00 0.00 99.40
February 2604.43 22-FEB-13:50 732.70 328.16 738.04 0.00 0.00 0.00 0.00 0.00 46.57
March 2233.99 16-MAR-14:40 732.70 328.16 738.04 0.00 0.00 0.00 0.00 0.00 23.18
April 2886.58 21-APR-14:25 1465.40 656.31 1476.09 0.00 0.00 0.00 0.00 175.85 0.00
May 5688.58 15-MAY-07:01 5128.89 2659.92 5166.30 0.00 0.00 0.00 0.00 0.00 60.99
June 5978.78 19-JUN-06:01 1077.07 1351.06 2583.15 0.00 0.00 0.00 0.00 0.00 541.43
July 5786.64 03-JUL-06:01 1077.07 1367.88 2583.15 0.00 0.00 0.00 0.00 0.00 41.59
August 6087.93 28-AUG-06:01 1077.07 1385.92 2583.15 0.00 0.00 0.00 0.00 0.00 910.06
September 6033.58 11-SEP-06:01 1077.07 1404.70 2583.15 0.00 0.00 0.00 0.00 0.00 1455.54
October 6108.54 23-OCT-07:02 3663.49 1872.60 3690.21 0.00 0.00 0.00 0.00 0.00 226.37
November 5861.06 10-NOV-08:62 3663.49 1640.78 3690.21 0.00 0.00 0.00 0.00 0.00 138.82
December 2389.06 18-DEC-13:10 1465.40 656.31 1476.09 0.00 0.00 0.00 0.00 0.00 315.18
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 2233.99   732.70 328.16 738.04 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 6108.54   5128.89 2659.92 5166.30 0.00 0.00 0.00 0.00 175.85 1455.54



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 494.73 27-JAN-07:04 638.93 871.22 1532.36 0.00 0.00 0.00 0.00 0.00 10.96
February 512.14 03-FEB-07:04 638.93 871.22 1532.36 0.00 0.00 0.00 0.00 0.00 3.94
March 735.45 16-MAR-10:43 1738.59 785.17 1751.27 0.00 0.00 0.00 0.00 0.00 3.49
April 4273.85 28-APR-07:02 2607.88 1168.00 2626.90 0.00 0.00 0.00 0.00 0.00 2.95
May 4277.98 12-MAY-07:01 3042.52 1362.66 3064.72 0.00 0.00 0.00 0.00 0.00 1.71
June 4317.10 19-JUN-06:01 638.93 698.42 1532.36 0.00 0.00 0.00 0.00 0.00 1.09
July 4207.56 03-JUL-06:01 638.93 635.90 1532.36 0.00 0.00 0.00 0.00 0.00 0.14
August 4388.87 28-AUG-06:01 638.93 768.57 1532.36 0.00 0.00 0.00 0.00 0.00 3.67
September 4372.71 11-SEP-06:01 638.93 816.25 1532.36 0.00 0.00 0.00 0.00 0.00 3.29
October 4339.04 23-OCT-07:02 2173.23 973.33 2189.08 0.00 0.00 0.00 0.00 0.00 5.45
November 4215.71 10-NOV-08:62 2173.23 973.33 2189.08 0.00 0.00 0.00 0.00 0.00 10.88
December 501.92 07-DEC-07:03 547.65 681.82 1313.45 0.00 0.00 0.00 0.00 0.00 6.48
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 494.73   547.65 635.90 1313.45 0.00 0.00 0.00 0.00 0.00 0.14
Maximum of Months 4388.87   3042.52 1362.66 3064.72 0.00 0.00 0.00 0.00 0.00 10.96



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 924.86 27-JAN-07:04 1077.07 1468.65 2583.15 0.00 0.00 0.00 0.00 0.00 16.41
February 818.61 10-FEB-07:05 923.20 1206.47 2214.13 0.00 0.00 0.00 0.00 0.00 13.14
March 775.74 02-MAR-07:04 1077.07 1419.18 2583.15 0.00 0.00 0.00 0.00 0.00 10.87
April 4728.21 20-APR-07:02 3663.49 2132.40 3690.21 0.00 0.00 0.00 0.00 0.00 1.94
May 5829.21 12-MAY-07:01 5128.89 2583.72 5166.30 0.00 0.00 0.00 0.00 0.00 2.32
June 5935.74 19-JUN-06:01 1077.07 1264.70 2583.15 0.00 0.00 0.00 0.00 0.00 1.68
July 5735.42 03-JUL-06:01 1077.07 1240.15 2583.15 0.00 0.00 0.00 0.00 0.00 0.27
August 6058.23 28-AUG-06:01 1077.07 1309.41 2583.15 0.00 0.00 0.00 0.00 0.00 5.58
September 5864.45 11-SEP-06:01 1077.07 1407.56 2583.15 0.00 0.00 0.00 0.00 0.00 4.66
October 5893.07 02-OCT-06:01 1077.07 1468.65 2583.15 0.00 0.00 0.00 0.00 0.00 2.80
November 3423.24 10-NOV-08:62 3663.49 2084.33 3690.21 0.00 0.00 0.00 0.00 0.00 14.59
December 885.79 22-DEC-07:04 1077.07 1468.65 2583.15 0.00 0.00 0.00 0.00 0.00 10.44
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 775.74   923.20 1206.47 2214.13 0.00 0.00 0.00 0.00 0.00 0.27
Maximum of Months 6058.23   5128.89 2583.72 5166.30 0.00 0.00 0.00 0.00 0.00 16.41



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 705.57 12-JAN-16:02 2173.23 973.33 2189.08 0.00 0.00 0.00 0.00 0.00 2.05
February 922.84 21-FEB-16:53 1738.59 778.66 1751.27 0.00 0.00 0.00 0.00 0.00 0.59
March 1310.79 16-MAR-15:53 1738.59 778.66 1751.27 0.00 0.00 0.00 0.00 0.00 1.56
April 4767.83 20-APR-07:02 2173.23 1274.53 2189.08 0.00 0.00 0.00 0.00 0.00 1.39
May 5028.65 12-MAY-07:01 3042.52 1706.54 3064.72 0.00 0.00 0.00 0.00 0.00 1.60
June 5121.95 19-JUN-06:01 638.93 822.59 1532.36 0.00 0.00 0.00 0.00 0.00 1.03
July 5350.43 04-JUL-17:11 0.00 462.96 747.37 0.00 0.00 0.00 0.00 0.00 11.26
August 5215.41 13-AUG-17:02 0.00 233.59 448.42 0.00 0.00 0.00 0.00 1.57 0.00
September 5231.60 11-SEP-06:01 638.93 849.73 1532.36 0.00 0.00 0.00 0.00 0.00 3.23
October 5087.63 02-OCT-06:01 638.93 871.22 1532.36 0.00 0.00 0.00 0.00 0.00 1.78
November 4330.68 10-NOV-08:62 2173.23 1241.43 2189.08 0.00 0.00 0.00 0.00 0.00 9.85
December 659.57 15-DEC-16:23 1738.59 978.30 1751.27 0.00 0.00 0.00 0.00 0.00 5.92
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 659.57   0.00 233.59 448.42 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 5350.43   3042.52 1706.54 3064.72 0.00 0.00 0.00 0.00 1.57 11.26



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: ATTIC

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY [] ZONE LIGHTS TOTAL HEATING ENERGY [] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1034.24 0.00
February 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 233.77 0.00
March 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 599.98 0.00
April 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1228.58 0.00
May 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1122.92 0.00
June 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 400.81 0.00
July 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1220.78 0.00
August 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 870.20 0.00
September 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 649.15 0.00
October 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1184.25 0.00
November 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1004.81 0.00
December 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 650.22 0.00
                       
Annual Sum or Average     0.00 0.00 0.00 0.00 0.00 0.00 0.00    
Minimum of Months 0.00   0.00 0.00 0.00 0.00 0.00 0.00 0.00 233.77 0.00
Maximum of Months 0.00   0.00 0.00 0.00 0.00 0.00 0.00 0.00 1228.58 0.00



Table of Contents

Report: EnergyConsumptionElectricityNaturalGasMonthly

For: Meter

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum} [W] ELECTRICITY:FACILITY {TIMESTAMP} NATURALGAS:FACILITY [J] NATURALGAS:FACILITY {Maximum} [W] NATURALGAS:FACILITY {TIMESTAMP}
January 0.119527E+11 13544.52 09-JAN-08:09 41770722.46 6497.58 27-JAN-07:10
February 0.106435E+11 14056.90 03-FEB-08:09 50162675.84 7376.79 03-FEB-07:10
March 0.121856E+11 14013.21 02-MAR-08:20 19194680.80 5886.61 02-MAR-07:10
April 0.116086E+11 13673.00 21-APR-14:00 0.00 0.00 01-APR-00:10
May 0.135861E+11 15258.63 30-MAY-15:30 0.00 0.00 01-MAY-00:10
June 0.147502E+11 16438.84 05-JUN-15:00 0.00 0.00 01-JUN-00:10
July 0.145067E+11 16599.90 03-JUL-14:09 0.00 0.00 01-JUL-00:10
August 0.155819E+11 16700.61 07-AUG-15:39 0.00 0.00 01-AUG-00:10
September 0.138482E+11 15971.85 05-SEP-15:20 0.00 0.00 01-SEP-00:10
October 0.132750E+11 15455.88 03-OCT-14:20 0.00 0.00 01-OCT-00:10
November 0.119811E+11 12821.55 03-NOV-15:00 2753497.00 3016.56 28-NOV-07:10
December 0.118529E+11 15280.56 27-DEC-08:39 78762237.04 8979.90 27-DEC-07:10
             
Annual Sum or Average 0.155772E+12     0.192644E+09    
Minimum of Months 0.106435E+11 12821.55   0.00 0.00  
Maximum of Months 0.155819E+11 16700.61   78762237.04 8979.90  



Table of Contents

Report: EndUseEnergyConsumptionElectricityMonthly

For: Meter

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

INTERIORLIGHTS:ELECTRICITY [J] EXTERIORLIGHTS:ELECTRICITY [J] INTERIOREQUIPMENT:ELECTRICITY [J] EXTERIOREQUIPMENT:ELECTRICITY [] FANS:ELECTRICITY [J] PUMPS:ELECTRICITY [J] HEATING:ELECTRICITY [J] COOLING:ELECTRICITY [J] HEATREJECTION:ELECTRICITY [] HUMIDIFIER:ELECTRICITY [] HEATRECOVERY:ELECTRICITY [] WATERSYSTEMS:ELECTRICITY [J] COGENERATION:ELECTRICITY []
January 0.225714E+10 0.102900E+10 0.405300E+10 0.00 0.191153E+10 0.02 0.544020E+09 0.107800E+09 0.00 0.00 0.00 0.205017E+10 0.00
February 0.203519E+10 0.852054E+09 0.366466E+10 0.00 0.172948E+10 0.00 0.380739E+09 0.129988E+09 0.00 0.00 0.00 0.185140E+10 0.00
March 0.233778E+10 0.836979E+09 0.429420E+10 0.00 0.209358E+10 0.00 0.245719E+09 0.305504E+09 0.00 0.00 0.00 0.207180E+10 0.00
April 0.211886E+10 0.713592E+09 0.388642E+10 0.00 0.182050E+10 0.00 9505681.26 0.112955E+10 0.00 0.00 0.00 0.193018E+10 0.00
May 0.226084E+10 0.657092E+09 0.417360E+10 0.00 0.200353E+10 0.00 0.00 0.250877E+10 0.00 0.00 0.00 0.198228E+10 0.00
June 0.223224E+10 0.599830E+09 0.412149E+10 0.00 0.200876E+10 0.00 0.00 0.388846E+10 0.00 0.00 0.00 0.189939E+10 0.00
July 0.215216E+10 0.640936E+09 0.393546E+10 0.00 0.183281E+10 0.00 0.00 0.404365E+10 0.00 0.00 0.00 0.190167E+10 0.00
August 0.232739E+10 0.705520E+09 0.429420E+10 0.00 0.210941E+10 0.00 0.00 0.419583E+10 0.00 0.00 0.00 0.194955E+10 0.00
September 0.213325E+10 0.762173E+09 0.388029E+10 0.00 0.183096E+10 0.00 0.00 0.337436E+10 0.00 0.00 0.00 0.186721E+10 0.00
October 0.223406E+10 0.898069E+09 0.405607E+10 0.00 0.191489E+10 0.00 0.00 0.220527E+10 0.00 0.00 0.00 0.196664E+10 0.00
November 0.222472E+10 0.965609E+09 0.400396E+10 0.00 0.191153E+10 0.00 0.115977E+09 0.809765E+09 0.00 0.00 0.00 0.194955E+10 0.00
December 0.220286E+10 0.105292E+10 0.393240E+10 0.00 0.182050E+10 0.00 0.735063E+09 96221633.28 0.00 0.00 0.00 0.201292E+10 0.00
                           
Annual Sum or Average 0.265165E+11 0.971377E+10 0.482958E+11 0.00 0.229875E+11 0.02 0.203102E+10 0.227952E+11 0.00 0.00 0.00 0.234328E+11 0.00
Minimum of Months 0.203519E+10 0.599830E+09 0.366466E+10 0.00 0.172948E+10 0.00 0.00 96221633.28 0.00 0.00 0.00 0.185140E+10 0.00
Maximum of Months 0.233778E+10 0.105292E+10 0.429420E+10 0.00 0.210941E+10 0.02 0.735063E+09 0.419583E+10 0.00 0.00 0.00 0.207180E+10 0.00



Table of Contents

Report: EndUseEnergyConsumptionNaturalGasMonthly

For: Meter

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

INTERIOREQUIPMENT:NATURALGAS [] EXTERIOREQUIPMENT:NATURALGAS [] HEATING:NATURALGAS [J] COOLING:NATURALGAS [] WATERSYSTEMS:NATURALGAS [] COGENERATION:NATURALGAS [] HUMIDIFIER:NATURALGAS []
January 0.00 0.00 41770722.46 0.00 0.00 0.00 0.00
February 0.00 0.00 50162675.84 0.00 0.00 0.00 0.00
March 0.00 0.00 19194680.80 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 2753497.00 0.00 0.00 0.00 0.00
December 0.00 0.00 78762237.04 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.192644E+09 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 78762237.04 0.00 0.00 0.00 0.00



Table of Contents

Report: PeakEnergyEndUseElectricityPart1Monthly

For: Meter

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

INTERIORLIGHTS:ELECTRICITY {Maximum} [W] INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} EXTERIOREQUIPMENT:ELECTRICITY [] FANS:ELECTRICITY {Maximum} [W] FANS:ELECTRICITY {TIMESTAMP} PUMPS:ELECTRICITY {Maximum} [W] PUMPS:ELECTRICITY {TIMESTAMP} HEATING:ELECTRICITY {Maximum} [W] HEATING:ELECTRICITY {TIMESTAMP}
January 2013.22 17-JAN-16:00 1049.10 01-JAN-06:10 3325.31 02-JAN-08:09 0.00 1944.98 02-JAN-08:30 0.00 02-JAN-08:00 5427.57 30-JAN-07:30
February 1987.26 23-FEB-16:00 1049.10 01-FEB-06:10 3325.31 01-FEB-08:09 0.00 1944.98 01-FEB-08:30 0.00 01-FEB-00:10 5458.06 03-FEB-07:30
March 1986.30 10-MAR-16:00 1049.10 01-MAR-06:10 3325.31 01-MAR-08:09 0.00 1944.98 01-MAR-08:20 0.00 01-MAR-00:10 4656.70 02-MAR-07:19
April 1948.92 20-APR-07:10 1049.10 01-APR-05:10 3325.31 03-APR-07:10 0.00 1944.98 03-APR-07:40 0.00 01-APR-00:10 1039.55 12-APR-06:10
May 1892.53 23-MAY-12:30 1049.10 01-MAY-05:10 3325.31 01-MAY-07:10 0.00 1944.98 01-MAY-06:40 0.00 01-MAY-00:10 0.00 01-MAY-00:10
June 1839.28 19-JUN-15:30 659.04 01-JUN-19:10 3325.31 01-JUN-07:10 0.00 1944.98 01-JUN-09:09 0.00 01-JUN-00:10 0.00 01-JUN-00:10
July 1946.66 07-JUL-07:30 1049.10 06-JUL-05:10 3325.31 03-JUL-07:10 0.00 1944.98 03-JUL-05:10 0.00 01-JUL-00:10 0.00 01-JUL-00:10
August 1942.35 17-AUG-07:10 1049.10 01-AUG-05:10 3325.31 01-AUG-07:10 0.00 1944.98 01-AUG-07:10 0.00 01-AUG-00:10 0.00 01-AUG-00:10
September 1904.02 08-SEP-07:10 1049.10 01-SEP-05:10 3325.31 01-SEP-07:10 0.00 1944.98 01-SEP-07:10 0.00 01-SEP-00:10 0.00 01-SEP-00:10
October 1998.88 13-OCT-07:10 1049.10 01-OCT-05:10 3325.31 02-OCT-07:10 0.00 1944.98 02-OCT-07:10 0.00 01-OCT-00:10 0.00 01-OCT-00:10
November 2025.66 22-NOV-16:00 1049.10 01-NOV-05:10 3325.31 01-NOV-07:10 0.00 1944.98 02-NOV-09:39 0.00 01-NOV-00:10 3853.95 28-NOV-07:10
December 2025.66 01-DEC-16:00 1049.10 01-DEC-06:10 3325.31 01-DEC-08:09 0.00 1944.98 01-DEC-08:50 0.00 01-DEC-00:10 7139.25 27-DEC-07:30
                           
Annual Sum or Average             0.00            
Minimum of Months 1839.28   659.04   3325.31   0.00 1944.98   0.00   0.00  
Maximum of Months 2025.66   1049.10   3325.31   0.00 1944.98   0.00   7139.25  



Table of Contents

Report: PeakEnergyEndUseElectricityPart2Monthly

For: Meter

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

COOLING:ELECTRICITY {Maximum} [W] COOLING:ELECTRICITY {TIMESTAMP} HEATREJECTION:ELECTRICITY [] HUMIDIFIER:ELECTRICITY [] HEATRECOVERY:ELECTRICITY [] WATERSYSTEMS:ELECTRICITY {Maximum} [W] WATERSYSTEMS:ELECTRICITY {TIMESTAMP} COGENERATION:ELECTRICITY []
January 1134.13 12-JAN-15:30 0.00 0.00 0.00 2797.01 30-JAN-12:39 0.00
February 1234.61 22-FEB-15:09 0.00 0.00 0.00 2796.96 02-FEB-12:20 0.00
March 1798.09 16-MAR-15:30 0.00 0.00 0.00 2793.83 02-MAR-12:50 0.00
April 3970.87 21-APR-14:00 0.00 0.00 0.00 2785.04 03-APR-11:09 0.00
May 5571.76 30-MAY-15:30 0.00 0.00 0.00 2774.79 02-MAY-11:09 0.00
June 6652.50 05-JUN-15:00 0.00 0.00 0.00 2764.31 01-JUN-11:00 0.00
July 6968.52 03-JUL-15:00 0.00 0.00 0.00 2756.22 03-JUL-11:39 0.00
August 7046.34 07-AUG-15:00 0.00 0.00 0.00 2756.72 31-AUG-11:00 0.00
September 6181.34 05-SEP-15:00 0.00 0.00 0.00 2764.13 29-SEP-11:39 0.00
October 5766.69 03-OCT-14:09 0.00 0.00 0.00 2775.35 31-OCT-11:00 0.00
November 3017.25 03-NOV-15:00 0.00 0.00 0.00 2785.86 30-NOV-12:30 0.00
December 782.60 15-DEC-15:50 0.00 0.00 0.00 2793.83 29-DEC-12:09 0.00
                 
Annual Sum or Average     0.00 0.00 0.00     0.00
Minimum of Months 782.60   0.00 0.00 0.00 2756.22   0.00
Maximum of Months 7046.34   0.00 0.00 0.00 2797.01   0.00



Table of Contents

Report: ElectricComponentsOfPeakDemandMonthly

For: Meter

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ELECTRICITY:FACILITY {Maximum} [W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] EXTERIOREQUIPMENT:ELECTRICITY [] FANS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] HEATREJECTION:ELECTRICITY []
January 13544.52 09-JAN-08:09 1954.91 3325.31 0.00 0.00 1944.98 0.00 3589.09 0.00 0.00
February 14056.90 03-FEB-08:09 1827.45 3325.31 0.00 0.00 1944.98 0.00 4228.68 0.00 0.00
March 14013.21 02-MAR-08:20 1814.22 3325.31 0.00 0.00 1944.98 0.00 4199.47 0.00 0.00
April 13673.00 21-APR-14:00 1710.58 3325.31 0.00 0.00 1944.98 0.00 0.00 3970.87 0.00
May 15258.63 30-MAY-15:30 1682.98 3325.31 0.00 0.00 1944.98 0.00 0.00 5571.76 0.00
June 16438.84 05-JUN-15:00 1783.83 3325.31 0.00 0.00 1944.98 0.00 0.00 6652.50 0.00
July 16599.90 03-JUL-14:09 1673.90 3325.31 0.00 0.00 1944.98 0.00 0.00 6946.55 0.00
August 16700.61 07-AUG-15:39 1729.33 3325.31 0.00 0.00 1944.98 0.00 0.00 6975.26 0.00
September 15971.85 05-SEP-15:20 1809.16 3325.31 0.00 0.00 1944.98 0.00 0.00 6163.85 0.00
October 15455.88 03-OCT-14:20 1712.56 3325.31 0.00 0.00 1944.98 0.00 0.00 5758.95 0.00
November 12821.55 03-NOV-15:00 1791.95 3325.31 0.00 0.00 1944.98 0.00 0.00 3017.25 0.00
December 15280.56 27-DEC-08:39 1772.50 3325.31 0.00 0.00 1944.98 0.00 5508.63 0.00 0.00
                       
Annual Sum or Average           0.00         0.00
Minimum of Months 12821.55   1673.90 3325.31 0.00 0.00 1944.98 0.00 0.00 0.00 0.00
Maximum of Months 16700.61   1954.91 3325.31 0.00 0.00 1944.98 0.00 5508.63 6975.26 0.00



Table of Contents

Report: PeakEnergyEndUseNaturalGasMonthly

For: Meter

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

INTERIOREQUIPMENT:NATURALGAS [] EXTERIOREQUIPMENT:NATURALGAS [] HEATING:NATURALGAS {Maximum} [W] HEATING:NATURALGAS {TIMESTAMP} COOLING:NATURALGAS [] WATERSYSTEMS:NATURALGAS [] COGENERATION:NATURALGAS []
January 0.00 0.00 6497.58 27-JAN-07:10 0.00 0.00 0.00
February 0.00 0.00 7376.79 03-FEB-07:10 0.00 0.00 0.00
March 0.00 0.00 5886.61 02-MAR-07:10 0.00 0.00 0.00
April 0.00 0.00 0.00 01-APR-00:10 0.00 0.00 0.00
May 0.00 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00
June 0.00 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00
July 0.00 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00
August 0.00 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00
September 0.00 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00
October 0.00 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00
November 0.00 0.00 3016.56 28-NOV-07:10 0.00 0.00 0.00
December 0.00 0.00 8979.90 27-DEC-07:10 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00     0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00   0.00 0.00 0.00
Maximum of Months 0.00 0.00 8979.90   0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.33 24.53 0.33 24.53
June 0.00 0.00 0.00 0.00 11.17 24.76 11.17 24.76
July 0.00 0.00 0.00 0.00 53.83 24.79 53.83 24.79
August 0.00 0.00 0.00 0.00 30.67 24.82 30.67 24.82
September 0.00 0.00 0.00 0.00 12.50 24.76 12.50 24.76
October 0.00 0.00 0.00 0.00 0.83 24.53 0.83 24.53
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   109.33 24.79 109.33 24.79
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 53.83 24.82 53.83 24.82



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 5.50 24.62 5.50 24.62
August 0.00 0.00 0.00 0.00 5.50 24.81 5.50 24.81
September 0.00 0.00 0.00 0.00 10.33 24.90 9.83 24.77
October 0.00 0.00 0.00 0.00 9.33 25.18 8.33 24.90
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   30.67 24.92 29.17 24.79
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 10.33 25.18 9.83 24.90



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 5.67 25.06 3.83 24.95
August 0.00 0.00 0.00 0.00 4.50 27.64 1.83 26.74
September 0.00 0.00 0.00 0.00 0.50 28.23 0.17 27.32
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   10.67 26.30 5.83 25.73
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 5.67 28.23 3.83 27.32



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 2.17 24.52 2.17 24.52
August 0.00 0.00 0.00 0.00 0.50 24.65 0.50 24.65
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   2.67 24.54 2.67 24.54
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 2.17 24.65 2.17 24.65



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.33 30.04 0.00 30.04
June 0.00 0.00 0.00 0.00 3.67 30.18 0.00 30.18
July 0.00 0.00 0.00 0.00 6.00 30.20 0.00 30.20
August 0.00 0.00 0.00 0.00 7.00 30.31 0.00 30.31
September 0.00 0.00 0.00 0.00 2.50 30.20 0.00 30.20
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   19.50 30.23 0.00 30.23
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 7.00 30.31 0.00 30.31



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: ATTIC

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: ComfortReportSimple55Monthly

For: CORE_ZN

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 357.00 22.42 23.17 22.29 23.17 22.18
February 323.00 22.85 17.00 22.78 17.00 22.71
March 382.50 23.42 3.17 23.40 3.17 23.37
April 87.83 23.89 95.00 24.60 0.00 24.60
May 7.83 26.42 302.00 25.17 7.83 25.21
June 34.83 27.55 365.67 25.46 34.83 25.63
July 115.00 27.16 340.00 25.91 115.00 26.16
August 82.33 27.16 391.00 25.62 82.33 25.85
September 35.00 27.07 340.00 25.33 35.00 25.48
October 16.83 26.16 281.83 25.04 16.83 25.10
November 215.67 23.54 53.00 23.79 0.00 23.79
December 340.00 22.45 26.83 22.30 26.83 22.16
             
Annual Sum or Average 1997.83 23.56 2238.67 24.36 362.00 24.48
Minimum of Months 7.83 22.42 3.17 22.29 0.00 22.16
Maximum of Months 382.50 27.55 391.00 25.91 115.00 26.16



Table of Contents

Report: ComfortReportSimple55Monthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 344.83 22.28 81.67 21.90 81.67 21.64
February 320.17 22.32 64.33 21.98 64.33 21.74
March 386.33 22.65 78.33 22.27 78.33 22.00
April 251.83 23.43 29.33 23.49 9.50 23.39
May 90.83 23.82 165.17 24.82 0.00 24.82
June 17.00 27.82 312.00 25.53 17.00 25.64
July 121.33 27.01 340.00 25.77 121.33 26.03
August 79.33 27.32 391.00 25.59 79.33 25.84
September 70.00 27.52 328.67 25.70 68.67 25.98
October 47.83 25.30 294.67 25.06 22.33 25.21
November 172.00 22.75 85.00 23.06 19.33 22.87
December 338.00 22.28 78.67 21.90 78.67 21.64
             
Annual Sum or Average 2239.50 23.28 2248.83 23.91 640.50 23.88
Minimum of Months 17.00 22.28 29.33 21.90 0.00 21.64
Maximum of Months 386.33 27.82 391.00 25.77 121.33 26.03



Table of Contents

Report: ComfortReportSimple55Monthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 294.00 21.16 163.83 20.82 163.83 20.66
February 266.00 21.58 116.67 21.16 116.67 20.94
March 322.00 22.45 74.67 22.04 74.67 21.76
April 171.17 23.68 36.00 23.92 4.00 23.86
May 17.33 24.47 203.17 25.36 2.00 25.38
June 49.17 27.91 299.83 25.94 49.17 26.19
July 117.17 27.56 280.00 26.27 117.17 26.56
August 75.17 27.83 322.00 26.00 75.17 26.29
September 46.50 27.65 278.17 25.78 46.50 26.01
October 30.50 24.11 170.00 24.98 2.83 25.01
November 250.00 22.95 38.50 22.73 30.17 22.50
December 280.00 21.20 147.67 20.84 147.67 20.66
             
Annual Sum or Average 1919.00 22.96 2130.50 23.60 829.83 23.48
Minimum of Months 17.33 21.16 36.00 20.82 2.00 20.66
Maximum of Months 322.00 27.91 322.00 26.27 163.83 26.56



Table of Contents

Report: ComfortReportSimple55Monthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 357.00 20.78 264.83 20.60 264.83 20.53
February 323.00 21.07 199.17 20.80 199.17 20.67
March 391.00 21.90 146.83 21.53 146.83 21.32
April 271.17 23.54 24.33 23.58 7.50 23.50
May 71.67 23.92 189.83 24.96 0.00 24.96
June 37.67 27.85 327.00 25.68 37.67 25.88
July 113.00 27.44 340.00 25.88 113.00 26.19
August 60.17 27.60 391.00 25.52 60.17 25.77
September 15.67 27.40 317.17 25.23 15.67 25.33
October 91.17 23.87 132.67 24.53 2.00 24.54
November 334.00 22.67 55.00 22.37 53.50 22.13
December 340.00 20.83 244.50 20.63 244.50 20.55
             
Annual Sum or Average 2405.50 22.43 2632.33 23.03 1144.83 22.80
Minimum of Months 15.67 20.78 24.33 20.60 0.00 20.53
Maximum of Months 391.00 27.85 391.00 25.88 264.83 26.19



Table of Contents

Report: ComfortReportSimple55Monthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 357.00 21.61 165.50 21.25 165.50 21.06
February 322.67 21.79 134.50 21.41 134.50 21.20
March 367.83 22.56 89.83 22.20 87.17 21.94
April 203.17 23.78 82.33 24.34 10.67 24.35
May 101.33 26.32 242.83 25.99 54.33 26.32
June 107.00 28.66 340.50 26.49 107.00 26.91
July 124.33 28.31 340.00 26.38 124.33 26.79
August 108.00 28.42 391.00 26.15 108.00 26.55
September 94.00 28.42 329.17 26.22 94.00 26.62
October 56.83 25.10 232.17 25.30 16.67 25.44
November 262.00 22.99 57.33 22.93 29.83 22.73
December 340.00 21.61 155.50 21.25 155.50 21.07
             
Annual Sum or Average 2444.17 23.59 2560.67 24.05 1087.50 24.08
Minimum of Months 56.83 21.61 57.33 21.25 10.67 21.06
Maximum of Months 367.83 28.66 391.00 26.49 165.50 26.91



Table of Contents

Report: ComfortReportSimple55Monthly

For: ATTIC

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00
             
Annual Sum or Average 0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 357.00000 0.00000 0.00000 0.00000 0.00000
February 323.00000 0.00000 0.00000 0.00000 0.00000
March 391.00000 0.00000 0.00000 0.00000 0.00000
April 340.00000 0.00000 0.00000 0.00000 0.00000
May 374.00000 0.00000 0.00000 0.00000 0.00000
June 374.00000 0.00000 0.00000 0.00000 0.00000
July 340.00000 0.00000 0.00000 0.00000 0.00000
August 391.00000 0.00000 0.00000 0.00000 0.00000
September 340.00000 0.00000 0.00000 0.00000 0.00000
October 357.00000 0.00000 0.00000 0.00000 0.00000
November 357.00000 0.00000 0.00000 0.00000 0.00000
December 340.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 4284.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 323.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 391.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 357.00000 0.00000 0.00000 0.00000 0.00000
February 323.00000 0.00000 0.00000 0.00000 0.00000
March 391.00000 0.00000 0.00000 0.00000 0.00000
April 340.00000 0.00000 0.00000 0.00000 0.00000
May 374.00000 0.00000 0.00000 0.00000 0.00000
June 374.00000 0.00000 0.00000 0.00000 0.00000
July 340.00000 0.00000 0.00000 0.00000 0.00000
August 391.00000 0.00000 0.00000 0.00000 0.00000
September 340.00000 0.00000 0.00000 0.00000 0.00000
October 357.00000 0.00000 0.00000 0.00000 0.00000
November 357.00000 0.00000 0.00000 0.00000 0.00000
December 340.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 4284.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 323.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 391.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 294.00000 0.00000 0.00000 0.00000 0.00000
February 266.00000 0.00000 0.00000 0.00000 0.00000
March 322.00000 0.00000 0.00000 0.00000 0.00000
April 280.00000 0.00000 0.00000 0.00000 0.00000
May 308.00000 0.00000 0.00000 0.00000 0.00000
June 308.00000 0.00000 0.00000 0.00000 0.00000
July 280.00000 0.00000 0.00000 0.00000 0.00000
August 322.00000 0.00000 0.00000 0.00000 0.00000
September 280.00000 0.00000 0.00000 0.00000 0.00000
October 294.00000 0.00000 0.00000 0.00000 0.00000
November 294.00000 0.00000 0.00000 0.00000 0.00000
December 280.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 3528.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 266.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 322.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 357.00000 0.00000 0.00000 0.00000 0.00000
February 323.00000 0.00000 0.00000 0.00000 0.00000
March 391.00000 0.00000 0.00000 0.00000 0.00000
April 340.00000 0.00000 0.00000 0.00000 0.00000
May 374.00000 0.00000 0.00000 0.00000 0.00000
June 374.00000 0.00000 0.00000 0.00000 0.00000
July 340.00000 0.00000 0.00000 0.00000 0.00000
August 391.00000 0.00000 0.00000 0.00000 0.00000
September 340.00000 0.00000 0.00000 0.00000 0.00000
October 357.00000 0.00000 0.00000 0.00000 0.00000
November 357.00000 0.00000 0.00000 0.00000 0.00000
December 340.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 4284.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 323.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 391.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 357.00000 0.00000 0.00000 0.00000 0.00000
February 323.00000 0.00000 0.00000 0.00000 0.00000
March 391.00000 0.00000 0.00000 0.00000 0.00000
April 340.00000 0.00000 0.00000 0.00000 0.00000
May 374.00000 0.00000 0.00000 0.00000 0.00000
June 374.00000 0.00000 0.00000 0.00000 0.00000
July 340.00000 0.00000 0.00000 0.00000 0.00000
August 391.00000 0.00000 0.00000 0.00000 0.00000
September 340.00000 0.00000 0.00000 0.00000 0.00000
October 357.00000 0.00000 0.00000 0.00000 0.00000
November 357.00000 0.00000 0.00000 0.00000 0.00000
December 340.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 4284.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 323.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 391.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: DXReportMonthly

For: PSZ-AC:1 HP COOLING COIL

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 49321191.51 11112512.23 27.38 47620808.49 1700383.02 0.00 0.23 13-JAN-16:00 0.00 01-JAN-00:10 1137.25 12-JAN-15:52 1092.78 13-JAN-16:00 97.54 12-JAN-17:00 253.86 12-JAN-15:52 0.00
February 0.136109E+09 30656854.97 59.72 0.134744E+09 1364975.18 0.00 0.31 23-FEB-15:00 0.00 01-FEB-00:10 1519.91 23-FEB-14:58 1519.91 23-FEB-14:58 58.18 08-FEB-12:00 337.49 22-FEB-15:53 0.00
March 0.483146E+09 0.108445E+09 135.97 0.482967E+09 179005.13 0.00 0.40 16-MAR-15:00 0.00 01-MAR-00:10 1978.99 16-MAR-15:00 1978.99 16-MAR-15:00 17.67 27-MAR-16:00 441.88 16-MAR-15:00 0.00
April 0.149387E+10 0.339850E+09 195.73 0.145656E+10 37309476.21 0.00 1.00 19-APR-07:02 0.00 01-APR-00:10 5825.21 19-APR-07:02 5627.19 20-APR-07:02 662.80 19-APR-07:02 1144.35 19-APR-07:02 0.00
May 0.297407E+10 0.676616E+09 234.21 0.282188E+10 0.152186E+09 0.00 1.00 01-MAY-07:02 0.00 01-MAY-00:10 6066.17 25-MAY-07:02 5802.36 31-MAY-06:02 1746.98 25-MAY-07:13 1361.98 30-MAY-15:00 0.00
June 0.402449E+10 0.953749E+09 244.50 0.377086E+10 0.253627E+09 0.00 1.00 01-JUN-06:03 0.00 01-JUN-00:10 6144.31 20-JUN-06:01 5920.75 19-JUN-05:03 1628.65 29-JUN-07:15 1441.69 05-JUN-16:05 0.00
July 0.423598E+10 0.954724E+09 230.40 0.348281E+10 0.753170E+09 0.00 1.00 03-JUL-05:02 0.00 01-JUL-00:10 6472.62 21-JUL-06:03 5926.99 03-JUL-05:02 2960.22 21-JUL-06:03 1463.40 03-JUL-16:00 0.00
August 0.450131E+10 0.999654E+09 257.22 0.379710E+10 0.704209E+09 0.00 1.00 01-AUG-06:01 0.00 01-AUG-00:10 6343.61 03-AUG-06:02 5763.03 23-AUG-06:02 2214.82 03-AUG-06:05 1440.42 07-AUG-15:53 0.00
September 0.361408E+10 0.797488E+09 219.65 0.311643E+10 0.497649E+09 0.00 1.00 01-SEP-06:03 0.00 01-SEP-00:10 6266.43 14-SEP-06:03 5448.56 18-SEP-14:55 2230.67 14-SEP-07:10 1349.31 18-SEP-16:00 0.00
October 0.254395E+10 0.548247E+09 217.02 0.223448E+10 0.309474E+09 0.00 1.00 02-OCT-06:01 0.00 01-OCT-00:10 6176.36 04-OCT-06:03 5652.22 02-OCT-06:01 1883.27 04-OCT-07:08 1328.31 03-OCT-14:00 0.00
November 0.948358E+09 0.207120E+09 162.79 0.887111E+09 61246500.38 0.00 1.00 01-NOV-07:03 0.00 01-NOV-00:10 5764.76 10-NOV-08:62 5541.16 09-NOV-08:62 543.22 01-NOV-13:20 1132.74 10-NOV-08:62 0.00
December 57108164.42 12927440.29 38.76 55810025.47 1298138.96 0.00 0.17 15-DEC-16:08 0.00 01-DEC-00:10 833.77 15-DEC-16:05 833.77 15-DEC-16:05 58.02 14-DEC-17:00 186.88 15-DEC-16:05 0.00
                                       
Annual Sum or Average 0.250618E+11 0.564059E+10 2023.34 0.222884E+11 0.277341E+10 0.00                         0.00
Minimum of Months 49321191.51 11112512.23 27.38 47620808.49 179005.13 0.00 0.17   0.00   833.77   833.77   17.67   186.88   0.00
Maximum of Months 0.450131E+10 0.999654E+09 257.22 0.379710E+10 0.753170E+09 0.00 1.00   0.00   6472.62   5926.99   2960.22   1463.40   0.00



Table of Contents

Report: DXReportMonthly

For: PSZ-AC:2 HP COOLING COIL

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.400219E+09 87914986.76 88.36 0.400219E+09 -0.0 0.00 0.53 12-JAN-14:55 0.00 01-JAN-00:10 3007.16 12-JAN-14:55 3007.16 12-JAN-14:55 0.00 02-JAN-16:38 637.74 12-JAN-14:55 0.00
February 0.355015E+09 78233239.63 77.02 0.355015E+09 -0.0 0.00 0.52 22-FEB-14:00 0.00 01-FEB-00:10 2916.67 22-FEB-14:00 2916.67 22-FEB-14:00 0.00 14-FEB-13:45 624.15 22-FEB-14:00 0.00
March 0.450708E+09 0.100951E+09 103.14 0.450708E+09 0.00 0.00 0.48 16-MAR-14:40 0.00 01-MAR-00:10 2612.19 16-MAR-14:40 2612.19 16-MAR-14:40 0.00 06-MAR-14:00 574.94 16-MAR-14:40 0.00
April 0.981182E+09 0.232253E+09 155.49 0.978727E+09 2455242.14 0.00 0.68 21-APR-14:15 0.00 01-APR-00:10 3752.82 21-APR-14:25 3752.82 21-APR-14:25 150.65 18-APR-16:00 968.04 21-APR-14:15 0.00
May 0.212742E+10 0.509838E+09 218.87 0.205690E+10 70518439.17 0.00 1.00 09-MAY-07:02 0.00 01-MAY-00:10 6544.35 23-MAY-07:02 6277.74 30-MAY-06:01 889.06 23-MAY-07:02 1315.67 30-MAY-06:01 0.00
June 0.340861E+10 0.849841E+09 233.63 0.327351E+10 0.135104E+09 0.00 1.00 01-JUN-07:01 0.00 01-JUN-00:10 6685.54 20-JUN-06:01 6488.76 19-JUN-06:01 1701.63 28-JUN-07:02 1565.80 05-JUN-16:08 0.00
July 0.387349E+10 0.905531E+09 220.12 0.329893E+10 0.574560E+09 0.00 1.00 03-JUL-05:02 0.00 01-JUL-00:10 7195.99 21-JUL-07:02 6460.62 03-JUL-05:02 3701.73 21-JUL-07:05 1596.32 03-JUL-16:05 0.00
August 0.415824E+10 0.956304E+09 252.79 0.366682E+10 0.491423E+09 0.00 1.00 01-AUG-06:01 0.00 01-AUG-00:10 6961.09 03-AUG-06:02 6587.76 07-AUG-05:02 2628.91 03-AUG-07:06 1569.69 07-AUG-15:53 0.00
September 0.374256E+10 0.843429E+09 222.39 0.340723E+10 0.335335E+09 0.00 1.00 01-SEP-07:02 0.00 01-SEP-00:10 6919.10 14-SEP-07:02 6298.61 11-SEP-07:02 2608.08 14-SEP-07:13 1488.10 19-SEP-16:08 0.00
October 0.300589E+10 0.644308E+09 219.11 0.282203E+10 0.183862E+09 0.00 1.00 01-OCT-14:13 0.00 01-OCT-00:10 6773.09 04-OCT-07:02 6437.69 02-OCT-05:03 2022.78 04-OCT-07:13 1494.11 01-OCT-14:53 0.00
November 0.153754E+10 0.323859E+09 152.48 0.151650E+10 21042671.21 0.00 1.00 10-NOV-08:62 0.00 01-NOV-00:10 6229.46 10-NOV-08:62 6229.46 10-NOV-08:62 384.23 03-NOV-10:53 1222.67 10-NOV-08:62 0.00
December 0.340687E+09 75174553.32 85.39 0.340687E+09 0.00 0.00 0.42 07-DEC-14:35 0.00 01-DEC-00:10 2322.54 07-DEC-14:35 2322.54 07-DEC-14:35 0.00 08-DEC-10:52 499.93 07-DEC-14:35 0.00
                                       
Annual Sum or Average 0.243816E+11 0.560764E+10 2028.80 0.225673E+11 0.181430E+10 0.00                         0.00
Minimum of Months 0.340687E+09 75174553.32 77.02 0.340687E+09 -0.0 0.00 0.42   0.00   2322.54   2322.54   0.00   499.93   0.00
Maximum of Months 0.415824E+10 0.956304E+09 252.79 0.366682E+10 0.574560E+09 0.00 1.00   0.00   7195.99   6587.76   3701.73   1596.32   0.00



Table of Contents

Report: DXReportMonthly

For: PSZ-AC:3 HP COOLING COIL

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 5353002.03 1221747.69 8.85 5353002.03 0.00 0.00 0.08 12-JAN-15:54 0.00 01-JAN-00:10 319.08 12-JAN-15:54 319.08 12-JAN-15:54 0.00 12-JAN-16:12 72.63 12-JAN-16:00 0.00
February 37984472.72 8657805.04 32.52 37984472.72 0.00 0.00 0.19 22-FEB-15:55 0.00 01-FEB-00:10 731.50 22-FEB-15:55 731.50 22-FEB-15:55 0.00 23-FEB-15:33 168.40 22-FEB-15:55 0.00
March 0.187906E+09 42833995.68 112.27 0.187906E+09 0.00 0.00 0.25 16-MAR-13:00 0.00 01-MAR-00:10 962.06 16-MAR-13:00 962.06 16-MAR-13:00 0.00 14-MAR-10:56 219.33 22-MAR-14:24 0.00
April 0.837221E+09 0.194927E+09 190.84 0.835284E+09 1937141.32 0.00 1.00 21-APR-07:02 0.00 01-APR-00:10 4534.16 28-APR-07:02 4534.16 28-APR-07:02 191.84 19-APR-07:02 889.70 28-APR-07:02 0.00
May 0.178379E+10 0.418629E+09 232.85 0.174529E+10 38501912.22 0.00 1.00 01-MAY-07:02 0.00 01-MAY-00:10 4840.82 25-MAY-07:02 4643.10 30-MAY-06:01 988.85 25-MAY-07:03 969.98 30-MAY-06:01 0.00
June 0.257134E+10 0.634118E+09 250.29 0.249844E+10 72901068.11 0.00 1.00 01-JUN-07:01 0.00 01-JUN-00:10 4877.02 20-JUN-06:01 4729.80 19-JUN-06:01 989.38 29-JUN-07:02 1081.31 18-JUN-17:01 0.00
July 0.275246E+10 0.648049E+09 250.27 0.246784E+10 0.284619E+09 0.00 1.00 03-JUL-05:02 0.00 01-JUL-00:10 5113.10 20-JUL-06:02 4743.92 03-JUL-05:02 1978.97 21-JUL-06:03 1155.24 03-JUL-16:00 0.00
August 0.290073E+10 0.671943E+09 284.56 0.265801E+10 0.242721E+09 0.00 1.00 01-AUG-06:01 0.00 01-AUG-00:10 5050.69 03-AUG-06:02 4818.44 06-AUG-09:22 1371.68 03-AUG-06:03 1140.35 07-AUG-16:05 0.00
September 0.231388E+10 0.528783E+09 233.94 0.215173E+10 0.162150E+09 0.00 1.00 01-SEP-07:02 0.00 01-SEP-00:10 4959.48 22-SEP-06:02 4614.01 26-SEP-07:02 1438.45 14-SEP-07:04 1013.41 18-SEP-10:43 0.00
October 0.140679E+10 0.313409E+09 213.89 0.132484E+10 81944961.55 0.00 1.00 02-OCT-06:01 0.00 01-OCT-00:10 4916.17 04-OCT-07:02 4704.04 02-OCT-06:01 1228.81 04-OCT-07:02 958.07 04-OCT-07:02 0.00
November 0.438499E+09 97535747.25 149.46 0.430704E+09 7795430.25 0.00 1.00 09-NOV-08:62 0.00 01-NOV-00:10 4585.06 10-NOV-08:62 4585.06 10-NOV-08:62 159.33 03-NOV-08:52 900.57 10-NOV-08:62 0.00
December 3402887.99 777351.94 9.18 3402887.99 -0.0 0.00 0.07 01-DEC-13:10 0.00 01-DEC-00:10 281.47 01-DEC-13:10 281.47 01-DEC-13:10 0.00 15-DEC-16:03 63.97 01-DEC-13:10 0.00
                                       
Annual Sum or Average 0.152394E+11 0.356088E+10 1968.92 0.143468E+11 0.892571E+09 0.00                         0.00
Minimum of Months 3402887.99 777351.94 8.85 3402887.99 -0.0 0.00 0.07   0.00   281.47   281.47   0.00   63.97   0.00
Maximum of Months 0.290073E+10 0.671943E+09 284.56 0.265801E+10 0.284619E+09 0.00 1.00   0.00   5113.10   4818.44   1978.97   1155.24   0.00



Table of Contents

Report: DXReportMonthly

For: PSZ-AC:4 HP COOLING COIL

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00
February 4154121.95 956812.37 5.39 4154121.95 -0.0 0.00 0.07 23-FEB-14:55 0.00 01-FEB-00:10 366.86 23-FEB-14:55 366.86 23-FEB-14:55 0.00 22-FEB-15:20 83.41 23-FEB-14:55 0.00
March 60000766.28 13900583.33 33.68 60000766.28 -0.0 0.00 0.20 16-MAR-15:40 0.00 01-MAR-00:10 1063.31 16-MAR-15:33 1063.31 16-MAR-15:33 0.00 21-MAR-15:57 242.59 16-MAR-15:33 0.00
April 0.767200E+09 0.183334E+09 158.74 0.763190E+09 4009744.40 0.00 0.88 20-APR-07:02 0.00 01-APR-00:10 5228.48 20-APR-07:02 5228.48 20-APR-07:02 154.46 18-APR-16:00 1044.31 20-APR-07:02 0.00
May 0.208817E+10 0.498733E+09 225.54 0.202175E+10 66413786.56 0.00 1.00 09-MAY-07:02 0.00 01-MAY-00:10 6530.10 25-MAY-07:02 6231.22 31-MAY-06:02 1483.06 25-MAY-07:02 1304.15 30-MAY-06:01 0.00
June 0.329344E+10 0.818436E+09 240.88 0.316494E+10 0.128498E+09 0.00 1.00 01-JUN-07:01 0.00 01-JUN-00:10 6587.60 20-JUN-06:01 6401.27 19-JUN-06:01 1502.98 29-JUN-07:04 1446.55 05-JUN-15:57 0.00
July 0.370795E+10 0.869876E+09 225.72 0.322318E+10 0.484770E+09 0.00 1.00 03-JUL-05:02 0.00 01-JUL-00:10 6939.30 21-JUL-07:02 6405.69 03-JUL-05:02 2958.55 21-JUL-07:05 1574.97 03-JUL-16:03 0.00
August 0.379818E+10 0.879697E+09 258.75 0.337919E+10 0.418991E+09 0.00 1.00 01-AUG-06:01 0.00 01-AUG-00:10 6829.46 03-AUG-06:02 6510.62 07-AUG-05:02 2119.84 03-AUG-07:06 1548.05 07-AUG-16:05 0.00
September 0.286528E+10 0.660846E+09 213.66 0.258736E+10 0.277921E+09 0.00 1.00 01-SEP-07:02 0.00 01-SEP-00:10 6716.69 14-SEP-07:02 6234.16 26-SEP-07:02 2135.37 14-SEP-07:13 1312.71 05-SEP-15:00 0.00
October 0.162613E+10 0.366278E+09 207.72 0.148556E+10 0.140569E+09 0.00 1.00 02-OCT-06:01 0.00 01-OCT-00:10 6661.04 04-OCT-07:02 6358.75 02-OCT-06:01 1837.99 04-OCT-07:04 1297.47 04-OCT-07:02 0.00
November 0.315456E+09 70950298.58 98.89 0.301348E+09 14107587.98 0.00 0.64 10-NOV-08:62 0.00 01-NOV-00:10 3702.14 10-NOV-08:62 3702.14 10-NOV-08:62 221.60 02-NOV-15:23 772.22 10-NOV-08:62 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 0.00 01-DEC-00:10 0.00 01-DEC-00:10 0.00 01-DEC-00:10 0.00 01-DEC-00:10 0.00 01-DEC-00:10 0.00
                                       
Annual Sum or Average 0.185260E+11 0.436301E+10 1668.96 0.169907E+11 0.153528E+10 0.00                         0.00
Minimum of Months 0.00 0.00 0.00 0.00 -0.0 0.00 0.00   0.00   0.00   0.00   0.00   0.00   0.00
Maximum of Months 0.379818E+10 0.879697E+09 258.75 0.337919E+10 0.484770E+09 0.00 1.00   0.00   6939.30   6510.62   2958.55   1574.97   0.00



Table of Contents

Report: DXReportMonthly

For: PSZ-AC:5 HP COOLING COIL

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 33325627.04 7551193.63 25.04 33325627.04 0.00 0.00 0.19 12-JAN-16:02 0.00 01-JAN-00:10 930.16 12-JAN-16:06 930.16 12-JAN-16:06 0.00 02-JAN-16:55 208.33 12-JAN-16:10 0.00
February 50432119.36 11483707.53 29.57 50432119.36 -0.0 0.00 0.27 21-FEB-16:53 0.00 01-FEB-00:10 1254.87 21-FEB-16:53 1254.87 21-FEB-16:53 0.00 08-FEB-16:38 282.32 21-FEB-16:53 0.00
March 0.171988E+09 39373778.88 78.75 0.171988E+09 0.00 0.00 0.34 16-MAR-16:00 0.00 01-MAR-00:10 1642.59 16-MAR-15:53 1642.59 16-MAR-15:53 0.00 09-MAR-12:13 365.35 16-MAR-15:53 0.00
April 0.753062E+09 0.179185E+09 180.57 0.749233E+09 3829219.43 0.00 1.00 20-APR-07:02 0.00 01-APR-00:10 5452.99 20-APR-07:02 5452.99 20-APR-07:02 147.60 18-APR-16:00 1069.29 20-APR-07:02 0.00
May 0.167280E+10 0.404952E+09 238.65 0.162852E+10 44277873.44 0.00 1.00 01-MAY-07:02 0.00 01-MAY-00:10 5849.41 25-MAY-07:02 5617.06 30-MAY-06:01 1187.73 25-MAY-07:02 1173.28 30-MAY-06:01 0.00
June 0.247442E+10 0.632321E+09 273.37 0.238959E+10 84833685.97 0.00 1.00 01-JUN-07:01 0.00 01-JUN-00:10 5902.15 20-JUN-06:01 5724.33 19-JUN-06:01 1087.76 29-JUN-07:02 1379.31 17-JUN-17:33 0.00
July 0.273328E+10 0.665469E+09 274.00 0.242416E+10 0.309117E+09 0.00 1.00 02-JUL-16:33 0.00 01-JUL-00:10 6174.76 21-JUL-07:02 5792.27 04-JUL-17:11 2466.99 21-JUL-07:03 1427.51 02-JUL-16:33 0.00
August 0.287789E+10 0.688228E+09 301.96 0.261015E+10 0.267741E+09 0.00 1.00 01-AUG-06:01 0.00 01-AUG-00:10 6092.49 03-AUG-06:02 5814.82 07-AUG-05:02 1635.55 03-AUG-07:02 1396.40 06-AUG-15:43 0.00
September 0.231030E+10 0.543814E+09 244.67 0.212762E+10 0.182687E+09 0.00 1.00 01-SEP-07:02 0.00 01-SEP-00:10 6020.39 14-SEP-06:03 5732.48 17-SEP-17:42 1518.59 14-SEP-07:02 1326.25 17-SEP-16:22 0.00
October 0.147264E+10 0.333032E+09 217.01 0.137501E+10 97623248.23 0.00 1.00 02-OCT-06:01 0.00 01-OCT-00:10 5938.76 04-OCT-07:02 5687.21 02-OCT-06:01 1428.72 04-OCT-07:02 1157.67 04-OCT-07:02 0.00
November 0.496015E+09 0.110300E+09 140.76 0.483921E+09 12094069.66 0.00 0.90 10-NOV-08:62 0.00 01-NOV-00:10 4896.05 10-NOV-08:62 4896.05 10-NOV-08:62 224.09 02-NOV-15:23 978.27 10-NOV-08:62 0.00
December 32403259.67 7342287.74 24.42 32403259.67 -0.0 0.00 0.17 15-DEC-16:23 0.00 01-DEC-00:10 780.04 15-DEC-16:27 780.04 15-DEC-16:27 0.00 05-DEC-16:33 174.87 15-DEC-16:27 0.00
                                       
Annual Sum or Average 0.150786E+11 0.362305E+10 2028.76 0.140764E+11 0.100220E+10 0.00                         0.00
Minimum of Months 32403259.67 7342287.74 24.42 32403259.67 -0.0 0.00 0.17   0.00   780.04   780.04   0.00   174.87   0.00
Maximum of Months 0.287789E+10 0.688228E+09 301.96 0.261015E+10 0.309117E+09 0.00 1.00   0.00   6174.76   5814.82   2466.99   1427.51   0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 84.08 64.08 20.00 116.59 54.30 0.00 0.00 0.00
February 77.86 55.31 22.55 110.81 47.44 0.00 0.00 0.00
March 55.86 30.85 25.01 80.65 40.70 0.00 0.00 0.00
April 29.42 6.17 23.24 43.09 25.90 0.00 0.00 0.00
May 23.03 0.00 23.03 37.27 16.94 0.00 0.00 0.00
June 22.72 0.00 22.72 46.35 10.19 0.00 0.00 0.00
July 21.77 0.04 21.73 42.62 9.59 0.00 0.00 0.00
August 23.16 1.93 21.24 42.05 13.25 0.00 0.00 0.00
September 42.17 19.23 22.93 73.91 24.85 0.00 0.00 0.00
October 69.77 47.15 22.62 108.97 35.41 0.00 0.00 0.00
November 86.93 66.64 20.29 123.18 52.16 0.00 0.00 0.00
December 86.11 65.03 21.08 116.46 60.28 0.00 0.00 0.00
                 
Annual Sum or Average 51.76 29.57 22.20 78.31 32.51 0.00 0.00 0.00
Minimum of Months 21.77 0.00 20.00 37.27 9.59 0.00 0.00 0.00
Maximum of Months 86.93 66.64 25.01 123.18 60.28 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 84.08 64.08 20.00 116.59 54.30 0.00 0.00 0.00
February 77.86 55.31 22.55 110.81 47.44 0.00 0.00 0.00
March 55.84 30.84 25.00 80.61 40.71 0.00 0.00 0.00
April 29.29 6.12 23.18 42.79 25.90 0.00 0.00 0.00
May 23.03 0.00 23.03 37.26 16.94 0.00 0.00 0.00
June 22.72 0.00 22.72 46.35 10.19 0.00 0.00 0.00
July 21.77 0.04 21.73 42.62 9.59 0.00 0.00 0.00
August 23.14 1.92 21.22 41.99 13.25 0.00 0.00 0.00
September 42.05 19.18 22.87 73.63 24.86 0.00 0.00 0.00
October 69.77 47.15 22.61 108.97 35.41 0.00 0.00 0.00
November 86.93 66.64 20.28 123.18 52.16 0.00 0.00 0.00
December 86.11 65.03 21.08 116.46 60.27 0.00 0.00 0.00
                 
Annual Sum or Average 51.74 29.55 22.19 78.25 32.51 0.00 0.00 0.00
Minimum of Months 21.77 0.00 20.00 37.26 9.59 0.00 0.00 0.00
Maximum of Months 86.93 66.64 25.00 123.18 60.27 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 84.08 64.08 20.00 116.59 54.30 0.00 0.00 0.00
February 77.86 55.31 22.55 110.81 47.44 0.00 0.00 0.00
March 55.84 30.84 25.00 80.61 40.71 0.00 0.00 0.00
April 29.29 6.12 23.18 42.79 25.90 0.00 0.00 0.00
May 23.03 0.00 23.03 37.26 16.94 0.00 0.00 0.00
June 22.72 0.00 22.72 46.35 10.19 0.00 0.00 0.00
July 21.77 0.04 21.73 42.62 9.59 0.00 0.00 0.00
August 23.14 1.92 21.22 41.98 13.25 0.00 0.00 0.00
September 42.04 19.18 22.86 73.61 24.86 0.00 0.00 0.00
October 69.77 47.15 22.61 108.97 35.41 0.00 0.00 0.00
November 86.93 66.64 20.28 123.18 52.16 0.00 0.00 0.00
December 86.11 65.03 21.08 116.46 60.27 0.00 0.00 0.00
                 
Annual Sum or Average 51.74 29.55 22.18 78.25 32.51 0.00 0.00 0.00
Minimum of Months 21.77 0.00 20.00 37.26 9.59 0.00 0.00 0.00
Maximum of Months 86.93 66.64 25.00 123.18 60.27 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 84.08 64.08 20.00 116.59 54.30 0.00 0.00 0.00
February 77.86 55.31 22.55 110.81 47.44 0.00 0.00 0.00
March 55.84 30.84 25.00 80.61 40.71 0.00 0.00 0.00
April 29.29 6.12 23.18 42.79 25.90 0.00 0.00 0.00
May 23.03 0.00 23.03 37.26 16.94 0.00 0.00 0.00
June 22.72 0.00 22.72 46.35 10.19 0.00 0.00 0.00
July 21.77 0.04 21.73 42.62 9.59 0.00 0.00 0.00
August 23.14 1.92 21.22 41.98 13.25 0.00 0.00 0.00
September 42.04 19.18 22.86 73.61 24.86 0.00 0.00 0.00
October 69.77 47.15 22.61 108.97 35.41 0.00 0.00 0.00
November 86.93 66.64 20.28 123.18 52.16 0.00 0.00 0.00
December 86.11 65.03 21.08 116.46 60.27 0.00 0.00 0.00
                 
Annual Sum or Average 51.74 29.55 22.18 78.25 32.51 0.00 0.00 0.00
Minimum of Months 21.77 0.00 20.00 37.26 9.59 0.00 0.00 0.00
Maximum of Months 86.93 66.64 25.00 123.18 60.27 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 84.08 64.08 20.00 116.59 54.30 0.00 0.00 0.00
February 77.86 55.31 22.55 110.81 47.44 0.00 0.00 0.00
March 55.84 30.84 25.00 80.61 40.71 0.00 0.00 0.00
April 29.29 6.12 23.18 42.79 25.90 0.00 0.00 0.00
May 23.03 0.00 23.03 37.26 16.94 0.00 0.00 0.00
June 22.72 0.00 22.72 46.35 10.19 0.00 0.00 0.00
July 21.77 0.04 21.73 42.62 9.59 0.00 0.00 0.00
August 23.14 1.92 21.22 41.98 13.25 0.00 0.00 0.00
September 42.05 19.18 22.87 73.61 24.84 0.00 0.00 0.00
October 69.77 47.15 22.61 108.97 35.41 0.00 0.00 0.00
November 86.93 66.64 20.28 123.18 52.16 0.00 0.00 0.00
December 86.11 65.03 21.08 116.46 60.27 0.00 0.00 0.00
                 
Annual Sum or Average 51.74 29.55 22.19 78.25 32.51 0.00 0.00 0.00
Minimum of Months 21.77 0.00 20.00 37.26 9.59 0.00 0.00 0.00
Maximum of Months 86.93 66.64 25.00 123.18 60.27 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 84.08 64.08 20.00 116.59 54.30 0.00 0.00 0.00
February 77.86 55.31 22.55 110.81 47.44 0.00 0.00 0.00
March 55.86 30.85 25.01 80.63 40.68 0.00 0.00 0.00
April 29.43 6.18 23.25 43.07 25.84 0.00 0.00 0.00
May 23.03 0.00 23.03 37.27 16.94 0.00 0.00 0.00
June 22.72 0.00 22.72 46.35 10.19 0.00 0.00 0.00
July 21.77 0.04 21.73 42.62 9.59 0.00 0.00 0.00
August 23.17 1.93 21.24 42.05 13.25 0.00 0.00 0.00
September 42.18 19.24 22.94 73.80 24.72 0.00 0.00 0.00
October 69.77 47.15 22.62 108.97 35.41 0.00 0.00 0.00
November 86.93 66.64 20.29 123.18 52.16 0.00 0.00 0.00
December 86.11 65.03 21.08 116.46 60.28 0.00 0.00 0.00
                 
Annual Sum or Average 51.77 29.57 22.20 78.29 32.49 0.00 0.00 0.00
Minimum of Months 21.77 0.00 20.00 37.27 9.59 0.00 0.00 0.00
Maximum of Months 86.93 66.64 25.01 123.18 60.28 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_DOOR

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 118.14 89.77 28.37 163.57 75.95 0.00 0.00 0.00
February 109.49 77.49 32.00 155.49 66.47 0.00 0.00 0.00
March 88.75 51.51 37.24 131.87 57.09 0.00 0.00 0.00
April 50.62 15.57 35.06 79.37 36.57 0.00 0.00 0.00
May 33.97 0.79 33.18 55.11 24.14 0.00 0.00 0.00
June 32.29 0.00 32.29 64.74 14.58 0.00 0.00 0.00
July 31.39 0.35 31.05 60.73 13.66 0.00 0.00 0.00
August 38.75 6.86 31.88 71.95 18.79 0.00 0.00 0.00
September 69.28 34.86 34.42 123.01 34.99 0.00 0.00 0.00
October 101.32 68.80 32.52 158.40 49.74 0.00 0.00 0.00
November 122.12 93.36 28.76 172.62 73.05 0.00 0.00 0.00
December 121.00 91.10 29.90 163.36 84.38 0.00 0.00 0.00
                 
Annual Sum or Average 76.24 44.02 32.22 116.44 45.68 0.00 0.00 0.00
Minimum of Months 31.39 0.00 28.37 55.11 13.66 0.00 0.00 0.00
Maximum of Months 122.12 93.36 37.24 172.62 84.38 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_2_WALL_EAST_WINDOW_4

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 31.58 17.21 14.38 33.24 50.55 0.00 0.00 0.00
February 42.15 24.07 18.07 51.03 44.21 0.00 0.00 0.00
March 51.45 28.28 23.17 66.90 37.58 0.00 0.00 0.00
April 61.73 33.94 27.79 91.21 24.30 0.00 0.00 0.00
May 63.30 33.97 29.33 102.47 16.83 0.00 0.00 0.00
June 63.01 34.43 28.58 112.87 10.43 0.00 0.00 0.00
July 56.59 29.22 27.37 100.10 9.80 0.00 0.00 0.00
August 53.96 27.23 26.73 92.24 12.98 0.00 0.00 0.00
September 54.11 30.70 23.41 86.70 22.75 0.00 0.00 0.00
October 41.88 22.55 19.33 57.75 32.88 0.00 0.00 0.00
November 37.95 22.13 15.82 42.30 49.78 0.00 0.00 0.00
December 31.63 16.87 14.76 30.78 58.07 0.00 0.00 0.00
                 
Annual Sum or Average 49.11 26.70 22.41 72.35 30.78 0.00 0.00 0.00
Minimum of Months 31.58 16.87 14.38 30.78 9.80 0.00 0.00 0.00
Maximum of Months 63.30 34.43 29.33 112.87 58.07 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_2_WALL_EAST_WINDOW_3

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 31.58 17.21 14.38 33.24 50.55 0.00 0.00 0.00
February 42.15 24.07 18.07 51.02 44.21 0.00 0.00 0.00
March 51.45 28.28 23.17 66.90 37.58 0.00 0.00 0.00
April 61.73 33.94 27.78 91.21 24.30 0.00 0.00 0.00
May 63.30 33.97 29.33 102.47 16.83 0.00 0.00 0.00
June 63.01 34.43 28.58 112.87 10.43 0.00 0.00 0.00
July 56.59 29.22 27.37 100.10 9.80 0.00 0.00 0.00
August 53.96 27.23 26.73 92.24 12.98 0.00 0.00 0.00
September 54.11 30.70 23.41 86.70 22.75 0.00 0.00 0.00
October 41.88 22.55 19.33 57.75 32.88 0.00 0.00 0.00
November 37.95 22.13 15.82 42.30 49.78 0.00 0.00 0.00
December 31.63 16.87 14.76 30.78 58.07 0.00 0.00 0.00
                 
Annual Sum or Average 49.11 26.70 22.41 72.35 30.78 0.00 0.00 0.00
Minimum of Months 31.58 16.87 14.38 30.78 9.80 0.00 0.00 0.00
Maximum of Months 63.30 34.43 29.33 112.87 58.07 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_2_WALL_EAST_WINDOW_2

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 31.58 17.21 14.38 33.24 50.55 0.00 0.00 0.00
February 42.15 24.07 18.07 51.02 44.21 0.00 0.00 0.00
March 51.45 28.28 23.17 66.90 37.58 0.00 0.00 0.00
April 61.73 33.94 27.78 91.21 24.30 0.00 0.00 0.00
May 63.30 33.97 29.33 102.47 16.83 0.00 0.00 0.00
June 63.01 34.43 28.58 112.87 10.43 0.00 0.00 0.00
July 56.59 29.22 27.37 100.10 9.80 0.00 0.00 0.00
August 53.96 27.23 26.73 92.24 12.98 0.00 0.00 0.00
September 54.11 30.70 23.41 86.70 22.75 0.00 0.00 0.00
October 41.88 22.55 19.33 57.75 32.88 0.00 0.00 0.00
November 37.95 22.13 15.82 42.30 49.78 0.00 0.00 0.00
December 31.63 16.87 14.76 30.78 58.07 0.00 0.00 0.00
                 
Annual Sum or Average 49.11 26.70 22.41 72.35 30.78 0.00 0.00 0.00
Minimum of Months 31.58 16.87 14.38 30.78 9.80 0.00 0.00 0.00
Maximum of Months 63.30 34.43 29.33 112.87 58.07 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_2_WALL_EAST_WINDOW_1

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 31.61 17.22 14.39 33.29 50.53 0.00 0.00 0.00
February 42.15 24.07 18.07 51.03 44.21 0.00 0.00 0.00
March 51.45 28.28 23.17 66.90 37.58 0.00 0.00 0.00
April 61.73 33.94 27.79 91.21 24.30 0.00 0.00 0.00
May 63.30 33.97 29.33 102.47 16.83 0.00 0.00 0.00
June 63.01 34.43 28.58 112.87 10.43 0.00 0.00 0.00
July 56.59 29.22 27.37 100.10 9.80 0.00 0.00 0.00
August 53.96 27.23 26.73 92.24 12.98 0.00 0.00 0.00
September 54.11 30.70 23.41 86.70 22.75 0.00 0.00 0.00
October 41.89 22.55 19.33 57.75 32.88 0.00 0.00 0.00
November 37.96 22.13 15.82 42.33 49.78 0.00 0.00 0.00
December 31.67 16.89 14.78 30.84 58.03 0.00 0.00 0.00
                 
Annual Sum or Average 49.12 26.70 22.42 72.37 30.78 0.00 0.00 0.00
Minimum of Months 31.61 16.89 14.39 30.84 9.80 0.00 0.00 0.00
Maximum of Months 63.30 34.43 29.33 112.87 58.03 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_1

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 11.86 0.00 11.86 4.29 52.63 0.00 0.00 0.00
February 14.50 0.00 14.50 9.58 45.77 0.00 0.00 0.00
March 18.94 0.00 18.94 17.02 39.01 0.00 0.00 0.00
April 21.99 0.17 21.83 27.93 24.26 0.00 0.00 0.00
May 25.70 1.68 24.02 41.47 16.11 0.00 0.00 0.00
June 26.90 2.87 24.03 54.09 10.07 0.00 0.00 0.00
July 25.09 2.21 22.88 48.80 9.34 0.00 0.00 0.00
August 21.54 0.40 21.14 38.65 12.49 0.00 0.00 0.00
September 18.92 0.01 18.91 29.94 23.22 0.00 0.00 0.00
October 15.62 0.00 15.62 16.14 33.37 0.00 0.00 0.00
November 12.63 0.00 12.63 4.95 52.14 0.00 0.00 0.00
December 11.75 0.00 11.75 2.68 61.10 0.00 0.00 0.00
                 
Annual Sum or Average 18.81 0.62 18.19 24.70 31.56 0.00 0.00 0.00
Minimum of Months 11.75 0.00 11.75 2.68 9.34 0.00 0.00 0.00
Maximum of Months 26.90 2.87 24.03 54.09 61.10 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_2

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 11.86 0.00 11.86 4.29 52.63 0.00 0.00 0.00
February 14.50 0.00 14.50 9.58 45.77 0.00 0.00 0.00
March 18.94 0.00 18.94 17.02 39.01 0.00 0.00 0.00
April 21.94 0.15 21.79 27.92 24.36 0.00 0.00 0.00
May 25.56 1.61 23.95 41.14 16.12 0.00 0.00 0.00
June 26.80 2.81 23.99 53.84 10.07 0.00 0.00 0.00
July 24.99 2.16 22.83 48.54 9.34 0.00 0.00 0.00
August 21.45 0.37 21.08 38.45 12.49 0.00 0.00 0.00
September 18.92 0.01 18.91 29.94 23.22 0.00 0.00 0.00
October 15.62 0.00 15.62 16.14 33.37 0.00 0.00 0.00
November 12.63 0.00 12.63 4.95 52.14 0.00 0.00 0.00
December 11.75 0.00 11.75 2.68 61.10 0.00 0.00 0.00
                 
Annual Sum or Average 18.77 0.60 18.17 24.61 31.56 0.00 0.00 0.00
Minimum of Months 11.75 0.00 11.75 2.68 9.34 0.00 0.00 0.00
Maximum of Months 26.80 2.81 23.99 53.84 61.10 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_3

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 11.86 0.00 11.86 4.29 52.63 0.00 0.00 0.00
February 14.50 0.00 14.50 9.58 45.77 0.00 0.00 0.00
March 18.94 0.00 18.94 17.02 39.01 0.00 0.00 0.00
April 21.94 0.15 21.78 27.92 24.37 0.00 0.00 0.00
May 25.56 1.61 23.95 41.14 16.12 0.00 0.00 0.00
June 26.80 2.81 23.99 53.84 10.07 0.00 0.00 0.00
July 24.99 2.16 22.83 48.54 9.34 0.00 0.00 0.00
August 21.45 0.37 21.08 38.45 12.50 0.00 0.00 0.00
September 18.92 0.01 18.91 29.94 23.22 0.00 0.00 0.00
October 15.62 0.00 15.62 16.14 33.37 0.00 0.00 0.00
November 12.63 0.00 12.63 4.95 52.14 0.00 0.00 0.00
December 11.75 0.00 11.75 2.68 61.10 0.00 0.00 0.00
                 
Annual Sum or Average 18.77 0.60 18.17 24.61 31.57 0.00 0.00 0.00
Minimum of Months 11.75 0.00 11.75 2.68 9.34 0.00 0.00 0.00
Maximum of Months 26.80 2.81 23.99 53.84 61.10 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_4

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 11.86 0.00 11.86 4.29 52.63 0.00 0.00 0.00
February 14.50 0.00 14.50 9.58 45.77 0.00 0.00 0.00
March 18.94 0.00 18.94 17.02 39.01 0.00 0.00 0.00
April 21.94 0.15 21.78 27.92 24.37 0.00 0.00 0.00
May 25.56 1.61 23.95 41.14 16.12 0.00 0.00 0.00
June 26.80 2.81 23.99 53.84 10.07 0.00 0.00 0.00
July 24.99 2.16 22.83 48.54 9.34 0.00 0.00 0.00
August 21.45 0.37 21.08 38.45 12.50 0.00 0.00 0.00
September 18.92 0.01 18.91 29.95 23.23 0.00 0.00 0.00
October 15.62 0.00 15.62 16.14 33.37 0.00 0.00 0.00
November 12.63 0.00 12.63 4.95 52.14 0.00 0.00 0.00
December 11.75 0.00 11.75 2.68 61.10 0.00 0.00 0.00
                 
Annual Sum or Average 18.77 0.60 18.17 24.62 31.57 0.00 0.00 0.00
Minimum of Months 11.75 0.00 11.75 2.68 9.34 0.00 0.00 0.00
Maximum of Months 26.80 2.81 23.99 53.84 61.10 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_5

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 11.86 0.00 11.86 4.29 52.63 0.00 0.00 0.00
February 14.50 0.00 14.50 9.58 45.77 0.00 0.00 0.00
March 18.94 0.00 18.94 17.02 39.01 0.00 0.00 0.00
April 21.94 0.15 21.79 27.93 24.37 0.00 0.00 0.00
May 25.56 1.61 23.95 41.14 16.12 0.00 0.00 0.00
June 26.80 2.81 23.99 53.84 10.07 0.00 0.00 0.00
July 24.99 2.16 22.83 48.54 9.34 0.00 0.00 0.00
August 21.45 0.37 21.08 38.45 12.50 0.00 0.00 0.00
September 18.92 0.01 18.91 29.96 23.23 0.00 0.00 0.00
October 15.62 0.00 15.62 16.14 33.37 0.00 0.00 0.00
November 12.63 0.00 12.63 4.95 52.14 0.00 0.00 0.00
December 11.75 0.00 11.75 2.68 61.10 0.00 0.00 0.00
                 
Annual Sum or Average 18.77 0.60 18.17 24.62 31.57 0.00 0.00 0.00
Minimum of Months 11.75 0.00 11.75 2.68 9.34 0.00 0.00 0.00
Maximum of Months 26.80 2.81 23.99 53.84 61.10 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_6

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 11.86 0.00 11.86 4.29 52.63 0.00 0.00 0.00
February 14.50 0.00 14.50 9.58 45.77 0.00 0.00 0.00
March 18.94 0.00 18.94 17.02 39.01 0.00 0.00 0.00
April 21.98 0.16 21.82 28.00 24.35 0.00 0.00 0.00
May 25.69 1.67 24.01 41.45 16.12 0.00 0.00 0.00
June 26.88 2.86 24.02 54.04 10.07 0.00 0.00 0.00
July 25.07 2.20 22.87 48.74 9.34 0.00 0.00 0.00
August 21.52 0.40 21.12 38.61 12.50 0.00 0.00 0.00
September 18.92 0.01 18.91 29.96 23.23 0.00 0.00 0.00
October 15.62 0.00 15.62 16.14 33.37 0.00 0.00 0.00
November 12.63 0.00 12.63 4.95 52.14 0.00 0.00 0.00
December 11.75 0.00 11.75 2.68 61.10 0.00 0.00 0.00
                 
Annual Sum or Average 18.80 0.61 18.19 24.70 31.57 0.00 0.00 0.00
Minimum of Months 11.75 0.00 11.75 2.68 9.34 0.00 0.00 0.00
Maximum of Months 26.88 2.86 24.02 54.04 61.10 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_4_WALL_WEST_WINDOW_4

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 33.40 18.90 14.49 38.60 54.10 0.00 0.00 0.00
February 37.20 19.73 17.47 46.13 47.53 0.00 0.00 0.00
March 50.48 27.03 23.45 68.08 41.06 0.00 0.00 0.00
April 57.58 30.74 26.84 87.10 27.26 0.00 0.00 0.00
May 61.66 32.49 29.17 101.43 19.48 0.00 0.00 0.00
June 59.67 31.34 28.32 108.42 12.13 0.00 0.00 0.00
July 52.82 25.76 27.06 94.86 11.26 0.00 0.00 0.00
August 51.51 25.84 25.67 89.39 14.66 0.00 0.00 0.00
September 53.30 29.49 23.81 88.17 25.88 0.00 0.00 0.00
October 46.47 27.11 19.36 67.80 35.97 0.00 0.00 0.00
November 39.32 24.00 15.32 48.41 53.65 0.00 0.00 0.00
December 31.68 17.34 14.35 34.22 61.58 0.00 0.00 0.00
                 
Annual Sum or Average 47.96 25.83 22.13 72.82 33.64 0.00 0.00 0.00
Minimum of Months 31.68 17.34 14.35 34.22 11.26 0.00 0.00 0.00
Maximum of Months 61.66 32.49 29.17 108.42 61.58 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_4_WALL_WEST_WINDOW_3

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 33.37 18.89 14.48 38.55 54.11 0.00 0.00 0.00
February 37.20 19.73 17.47 46.13 47.53 0.00 0.00 0.00
March 50.48 27.03 23.45 68.08 41.06 0.00 0.00 0.00
April 57.58 30.74 26.84 87.10 27.26 0.00 0.00 0.00
May 61.66 32.49 29.17 101.43 19.48 0.00 0.00 0.00
June 59.67 31.34 28.32 108.42 12.13 0.00 0.00 0.00
July 52.82 25.76 27.06 94.86 11.26 0.00 0.00 0.00
August 51.51 25.84 25.66 89.39 14.66 0.00 0.00 0.00
September 53.30 29.49 23.81 88.17 25.88 0.00 0.00 0.00
October 46.47 27.11 19.36 67.80 35.97 0.00 0.00 0.00
November 39.31 23.99 15.32 48.38 53.66 0.00 0.00 0.00
December 31.65 17.31 14.33 34.15 61.61 0.00 0.00 0.00
                 
Annual Sum or Average 47.96 25.83 22.13 72.81 33.65 0.00 0.00 0.00
Minimum of Months 31.65 17.31 14.33 34.15 11.26 0.00 0.00 0.00
Maximum of Months 61.66 32.49 29.17 108.42 61.61 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_4_WALL_WEST_WINDOW_2

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 33.37 18.89 14.48 38.55 54.11 0.00 0.00 0.00
February 37.20 19.73 17.47 46.13 47.53 0.00 0.00 0.00
March 50.48 27.03 23.45 68.08 41.06 0.00 0.00 0.00
April 57.58 30.74 26.84 87.10 27.26 0.00 0.00 0.00
May 61.66 32.49 29.17 101.43 19.48 0.00 0.00 0.00
June 59.67 31.34 28.32 108.42 12.13 0.00 0.00 0.00
July 52.82 25.76 27.06 94.86 11.26 0.00 0.00 0.00
August 51.51 25.84 25.66 89.39 14.66 0.00 0.00 0.00
September 53.30 29.49 23.81 88.17 25.88 0.00 0.00 0.00
October 46.47 27.11 19.36 67.80 35.97 0.00 0.00 0.00
November 39.31 23.99 15.32 48.38 53.66 0.00 0.00 0.00
December 31.65 17.31 14.33 34.15 61.61 0.00 0.00 0.00
                 
Annual Sum or Average 47.96 25.83 22.13 72.81 33.65 0.00 0.00 0.00
Minimum of Months 31.65 17.31 14.33 34.15 11.26 0.00 0.00 0.00
Maximum of Months 61.66 32.49 29.17 108.42 61.61 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_4_WALL_WEST_WINDOW_1

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 33.37 18.89 14.48 38.55 54.11 0.00 0.00 0.00
February 37.20 19.73 17.47 46.13 47.53 0.00 0.00 0.00
March 50.48 27.03 23.45 68.08 41.06 0.00 0.00 0.00
April 57.58 30.74 26.84 87.10 27.26 0.00 0.00 0.00
May 61.66 32.49 29.17 101.43 19.48 0.00 0.00 0.00
June 59.67 31.34 28.32 108.42 12.13 0.00 0.00 0.00
July 52.82 25.76 27.06 94.86 11.26 0.00 0.00 0.00
August 51.51 25.84 25.67 89.39 14.66 0.00 0.00 0.00
September 53.30 29.49 23.81 88.17 25.88 0.00 0.00 0.00
October 46.47 27.11 19.36 67.80 35.97 0.00 0.00 0.00
November 39.31 23.99 15.32 48.38 53.66 0.00 0.00 0.00
December 31.65 17.31 14.33 34.15 61.61 0.00 0.00 0.00
                 
Annual Sum or Average 47.96 25.83 22.13 72.81 33.65 0.00 0.00 0.00
Minimum of Months 31.65 17.31 14.33 34.15 11.26 0.00 0.00 0.00
Maximum of Months 61.66 32.49 29.17 108.42 61.61 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.225192E+09 0.171626E+09 53566574.08 0.312282E+09 0.145433E+09
February 0.188356E+09 0.133808E+09 54547512.30 0.268078E+09 0.114764E+09
March 0.149611E+09 82632871.89 66978603.43 0.216004E+09 0.109015E+09
April 76250186.54 16004119.40 60246067.14 0.111677E+09 67127021.37
May 61691700.75 612.13 61691088.61 99817320.57 45361730.26
June 58893335.63 0.05 58893335.58 0.120131E+09 26404571.39
July 58304949.74 112730.30 58192219.43 0.114160E+09 25689027.01
August 62041594.22 5164334.73 56877259.49 0.112626E+09 35493065.16
September 0.109299E+09 49852341.03 59446608.45 0.191580E+09 64420267.96
October 0.186866E+09 0.126293E+09 60572738.86 0.291863E+09 94845641.46
November 0.225312E+09 0.172733E+09 52579053.81 0.319290E+09 0.135194E+09
December 0.230634E+09 0.174169E+09 56464501.18 0.311927E+09 0.161442E+09
           
Annual Sum or Average 0.163245E+10 0.932396E+09 0.700056E+09 0.246944E+10 0.102519E+10
Minimum of Months 58304949.74 0.05 52579053.81 99817320.57 25689027.01
Maximum of Months 0.230634E+09 0.174169E+09 66978603.43 0.319290E+09 0.161442E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.225191E+09 0.171626E+09 53565090.36 0.312281E+09 0.145431E+09
February 0.188354E+09 0.133808E+09 54545915.92 0.268077E+09 0.114762E+09
March 0.149564E+09 82604913.50 66959254.00 0.215907E+09 0.109026E+09
April 75926422.30 15854738.78 60071683.52 0.110915E+09 67142428.23
May 61685411.62 0.00 61685411.62 99807532.38 45359537.69
June 58891440.44 0.00 58891440.44 0.120130E+09 26403096.79
July 58301064.78 111478.54 58189586.24 0.114153E+09 25687818.36
August 61971489.91 5134301.43 56837188.48 0.112455E+09 35491655.59
September 0.108990E+09 49707174.16 59282499.00 0.190846E+09 64441303.22
October 0.186864E+09 0.126293E+09 60570901.10 0.291862E+09 94843573.59
November 0.225311E+09 0.172733E+09 52577664.42 0.319289E+09 0.135192E+09
December 0.230632E+09 0.174169E+09 56462965.43 0.311926E+09 0.161439E+09
           
Annual Sum or Average 0.163168E+10 0.932042E+09 0.699640E+09 0.246765E+10 0.102522E+10
Minimum of Months 58301064.78 0.00 52577664.42 99807532.38 25687818.36
Maximum of Months 0.230632E+09 0.174169E+09 66959254.00 0.319289E+09 0.161439E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.225191E+09 0.171626E+09 53565090.36 0.312281E+09 0.145431E+09
February 0.188354E+09 0.133808E+09 54545915.92 0.268077E+09 0.114762E+09
March 0.149564E+09 82604913.50 66959254.00 0.215907E+09 0.109026E+09
April 75926422.30 15854738.78 60071683.52 0.110915E+09 67142428.23
May 61685411.62 0.00 61685411.62 99807532.38 45359537.69
June 58891440.44 0.00 58891440.44 0.120130E+09 26403096.79
July 58301064.78 111478.54 58189586.24 0.114153E+09 25687818.36
August 61970906.15 5133733.19 56837172.96 0.112452E+09 35491655.59
September 0.108963E+09 49702665.20 59260225.88 0.190798E+09 64449768.01
October 0.186864E+09 0.126293E+09 60570901.10 0.291862E+09 94843573.59
November 0.225311E+09 0.172733E+09 52577664.42 0.319289E+09 0.135192E+09
December 0.230632E+09 0.174169E+09 56462965.43 0.311926E+09 0.161439E+09
           
Annual Sum or Average 0.163165E+10 0.932037E+09 0.699617E+09 0.246760E+10 0.102523E+10
Minimum of Months 58301064.78 0.00 52577664.42 99807532.38 25687818.36
Maximum of Months 0.230632E+09 0.174169E+09 66959254.00 0.319289E+09 0.161439E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.225191E+09 0.171626E+09 53565090.36 0.312281E+09 0.145431E+09
February 0.188354E+09 0.133808E+09 54545915.92 0.268077E+09 0.114762E+09
March 0.149564E+09 82604913.50 66959254.00 0.215907E+09 0.109026E+09
April 75926422.30 15854738.78 60071683.52 0.110915E+09 67142428.23
May 61685411.62 0.00 61685411.62 99807532.38 45359537.69
June 58891440.44 0.00 58891440.44 0.120130E+09 26403096.79
July 58301064.78 111478.54 58189586.24 0.114153E+09 25687818.36
August 61970902.98 5133730.02 56837172.96 0.112452E+09 35491644.23
September 0.108965E+09 49702648.79 59262065.83 0.190796E+09 64444368.83
October 0.186864E+09 0.126293E+09 60570901.10 0.291862E+09 94843573.59
November 0.225311E+09 0.172733E+09 52577664.42 0.319289E+09 0.135192E+09
December 0.230632E+09 0.174169E+09 56462965.43 0.311926E+09 0.161439E+09
           
Annual Sum or Average 0.163166E+10 0.932037E+09 0.699619E+09 0.246760E+10 0.102522E+10
Minimum of Months 58301064.78 0.00 52577664.42 99807532.38 25687818.36
Maximum of Months 0.230632E+09 0.174169E+09 66959254.00 0.319289E+09 0.161439E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.225191E+09 0.171626E+09 53565090.36 0.312281E+09 0.145431E+09
February 0.188354E+09 0.133808E+09 54545915.92 0.268077E+09 0.114762E+09
March 0.149564E+09 82604913.50 66959254.00 0.215907E+09 0.109026E+09
April 75926422.30 15854738.78 60071683.52 0.110915E+09 67142428.23
May 61685411.62 0.00 61685411.62 99807532.38 45359537.69
June 58891440.44 0.00 58891440.44 0.120130E+09 26403096.79
July 58301064.78 111478.54 58189586.24 0.114153E+09 25687818.36
August 61971522.41 5134349.45 56837172.96 0.112452E+09 35489224.40
September 0.108997E+09 49708115.63 59288953.97 0.190796E+09 64374494.75
October 0.186864E+09 0.126293E+09 60570901.10 0.291862E+09 94843573.59
November 0.225311E+09 0.172733E+09 52577664.42 0.319289E+09 0.135192E+09
December 0.230632E+09 0.174169E+09 56462965.43 0.311926E+09 0.161439E+09
           
Annual Sum or Average 0.163169E+10 0.932043E+09 0.699646E+09 0.246760E+10 0.102515E+10
Minimum of Months 58301064.78 0.00 52577664.42 99807532.38 25687818.36
Maximum of Months 0.230632E+09 0.174169E+09 66959254.00 0.319289E+09 0.161439E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.225192E+09 0.171626E+09 53566574.00 0.312282E+09 0.145433E+09
February 0.188356E+09 0.133808E+09 54547512.22 0.268078E+09 0.114764E+09
March 0.149613E+09 82634625.18 66978680.04 0.215960E+09 0.108965E+09
April 76291495.57 16025139.85 60266355.72 0.111642E+09 66969851.78
May 61691707.84 685.63 61691022.21 99817699.94 45361730.15
June 58893335.54 0.06 58893335.48 0.120131E+09 26404571.31
July 58304421.19 112291.56 58192129.63 0.114159E+09 25689026.94
August 62048583.29 5168033.22 56880550.07 0.112636E+09 35481190.09
September 0.109318E+09 49869557.09 59448678.34 0.191299E+09 64071221.01
October 0.186866E+09 0.126293E+09 60572738.77 0.291863E+09 94845641.35
November 0.225312E+09 0.172733E+09 52579053.74 0.319290E+09 0.135194E+09
December 0.230634E+09 0.174169E+09 56464501.10 0.311927E+09 0.161442E+09
           
Annual Sum or Average 0.163252E+10 0.932440E+09 0.700081E+09 0.246908E+10 0.102462E+10
Minimum of Months 58304421.19 0.06 52579053.74 99817699.94 25689026.94
Maximum of Months 0.230634E+09 0.174169E+09 66978680.04 0.319290E+09 0.161442E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_DOOR

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.316428E+09 0.240450E+09 75978480.75 0.438095E+09 0.203417E+09
February 0.264890E+09 0.187467E+09 77423481.24 0.376152E+09 0.160796E+09
March 0.237712E+09 0.137961E+09 99751849.32 0.353213E+09 0.152908E+09
April 0.131216E+09 40349953.74 90865660.23 0.205716E+09 94791372.23
May 90989985.15 2110482.98 88879502.17 0.147613E+09 64663185.58
June 83699503.64 0.00 83699503.64 0.167805E+09 37787387.56
July 84082819.91 928821.92 83153997.99 0.162660E+09 36583510.24
August 0.103787E+09 18385818.46 85400728.56 0.192703E+09 50339128.27
September 0.179571E+09 90353721.43 89216961.05 0.318845E+09 90692790.57
October 0.271387E+09 0.184274E+09 87112963.92 0.424248E+09 0.133228E+09
November 0.316537E+09 0.242002E+09 74535760.54 0.447428E+09 0.189346E+09
December 0.324085E+09 0.244014E+09 80071158.40 0.437542E+09 0.226009E+09
           
Annual Sum or Average 0.240439E+10 0.138830E+10 0.101609E+10 0.367202E+10 0.144056E+10
Minimum of Months 83699503.64 0.00 74535760.54 0.147613E+09 36583510.24
Maximum of Months 0.324085E+09 0.244014E+09 99751849.32 0.447428E+09 0.226009E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_2_WALL_EAST_WINDOW_4

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 84588931.82 46084663.98 38504267.84 89027274.44 0.135385E+09
February 0.101961E+09 58238891.32 43721988.06 0.123440E+09 0.106962E+09
March 0.137814E+09 75748969.58 62064849.28 0.179177E+09 0.100651E+09
April 0.160002E+09 87981412.23 72020562.02 0.236416E+09 62988906.09
May 0.169549E+09 90978255.75 78570750.09 0.274457E+09 45087438.01
June 0.163331E+09 89251867.63 74079585.97 0.292558E+09 27037738.71
July 0.151572E+09 78266979.67 73304855.06 0.268108E+09 26244291.55
August 0.144523E+09 72937048.22 71585978.93 0.247060E+09 34758878.00
September 0.140261E+09 79581514.93 60679894.90 0.224728E+09 58969455.43
October 0.112181E+09 60404908.52 51776195.15 0.154673E+09 88056061.87
November 98356233.58 57351383.02 41004850.56 0.109633E+09 0.129034E+09
December 84709324.18 45179439.84 39529884.34 82435418.49 0.155527E+09
           
Annual Sum or Average 0.154885E+10 0.842005E+09 0.706844E+09 0.228171E+10 0.970702E+09
Minimum of Months 84588931.82 45179439.84 38504267.84 82435418.49 26244291.55
Maximum of Months 0.169549E+09 90978255.75 78570750.09 0.292558E+09 0.155527E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_2_WALL_EAST_WINDOW_3

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 84587448.18 46084663.98 38502784.20 89026313.79 0.135383E+09
February 0.101959E+09 58238891.32 43720391.76 0.123439E+09 0.106960E+09
March 0.137811E+09 75748969.58 62062430.59 0.179175E+09 0.100648E+09
April 0.160000E+09 87981412.23 72018366.40 0.236415E+09 62986640.19
May 0.169547E+09 90978255.75 78568463.83 0.274455E+09 45085213.20
June 0.163330E+09 89251867.63 74077690.92 0.292557E+09 27036245.62
July 0.151570E+09 78266979.67 73302619.50 0.268106E+09 26243079.55
August 0.144521E+09 72937048.22 71583814.86 0.247058E+09 34757459.56
September 0.140260E+09 79581514.93 60678077.13 0.224727E+09 58967643.77
October 0.112179E+09 60404908.52 51774357.48 0.154671E+09 88054095.02
November 98354844.26 57351383.02 41003461.24 0.109633E+09 0.129032E+09
December 84707788.51 45179439.84 39528348.68 82434593.05 0.155524E+09
           
Annual Sum or Average 0.154883E+10 0.842005E+09 0.706821E+09 0.228170E+10 0.970679E+09
Minimum of Months 84587448.18 45179439.84 38502784.20 82434593.05 26243079.55
Maximum of Months 0.169547E+09 90978255.75 78568463.83 0.292557E+09 0.155524E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_2_WALL_EAST_WINDOW_2

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 84587448.18 46084663.98 38502784.20 89026313.79 0.135383E+09
February 0.101959E+09 58238891.32 43720391.76 0.123439E+09 0.106960E+09
March 0.137811E+09 75748969.58 62062430.59 0.179175E+09 0.100648E+09
April 0.160000E+09 87981412.23 72018366.40 0.236415E+09 62986640.19
May 0.169547E+09 90978255.75 78568463.83 0.274455E+09 45085213.20
June 0.163330E+09 89251867.63 74077690.92 0.292557E+09 27036245.62
July 0.151570E+09 78266979.67 73302619.50 0.268106E+09 26243079.55
August 0.144521E+09 72937048.22 71583814.86 0.247058E+09 34757459.56
September 0.140260E+09 79581514.93 60678077.13 0.224727E+09 58967643.77
October 0.112179E+09 60404908.52 51774357.48 0.154671E+09 88054095.02
November 98354844.26 57351383.02 41003461.24 0.109633E+09 0.129032E+09
December 84707788.51 45179439.84 39528348.68 82434593.05 0.155524E+09
           
Annual Sum or Average 0.154883E+10 0.842005E+09 0.706821E+09 0.228170E+10 0.970679E+09
Minimum of Months 84587448.18 45179439.84 38502784.20 82434593.05 26243079.55
Maximum of Months 0.169547E+09 90978255.75 78568463.83 0.292557E+09 0.155524E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_2_WALL_EAST_WINDOW_1

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 84654438.50 46124458.11 38529980.39 89155615.79 0.135345E+09
February 0.101964E+09 58240557.24 43723039.04 0.123447E+09 0.106961E+09
March 0.137814E+09 75749049.64 62064875.55 0.179178E+09 0.100651E+09
April 0.160002E+09 87981412.23 72020562.14 0.236416E+09 62988906.21
May 0.169549E+09 90978255.75 78570750.20 0.274457E+09 45087438.13
June 0.163331E+09 89251867.63 74079586.07 0.292558E+09 27037738.79
July 0.151572E+09 78266979.67 73304855.18 0.268108E+09 26244291.61
August 0.144523E+09 72937048.22 71585979.04 0.247060E+09 34758878.07
September 0.140261E+09 79581514.93 60679895.00 0.224728E+09 58969455.52
October 0.112185E+09 60408046.62 51777116.25 0.154684E+09 88056061.97
November 98389131.93 57371859.62 41017272.31 0.109711E+09 0.129027E+09
December 84811939.83 45237134.36 39574805.47 82602218.75 0.155433E+09
           
Annual Sum or Average 0.154906E+10 0.842128E+09 0.706929E+09 0.228210E+10 0.970560E+09
Minimum of Months 84654438.50 45237134.36 38529980.39 82602218.75 26244291.61
Maximum of Months 0.169549E+09 90978255.75 78570750.20 0.292558E+09 0.155433E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_1

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 31769790.58 0.00 31769790.58 11497494.62 0.140960E+09
February 35076309.21 0.00 35076309.21 23185844.53 0.110731E+09
March 50725863.55 0.00 50725863.55 45597462.46 0.104492E+09
April 57008331.92 429605.34 56578726.59 72407258.88 62888248.64
May 68830061.14 4494778.02 64335283.12 0.111085E+09 43148769.27
June 69718777.27 7438848.35 62279928.92 0.140193E+09 26103408.90
July 67207577.43 5930897.48 61276679.95 0.130709E+09 25007121.00
August 57694312.57 1082151.98 56612160.59 0.103518E+09 33456137.41
September 49041905.19 18881.22 49023023.97 77613901.07 60181984.52
October 41839675.28 0.00 41839675.28 43233116.14 89370886.07
November 32729410.48 0.00 32729410.48 12824300.53 0.135148E+09
December 31466178.43 0.00 31466178.43 7187533.95 0.163646E+09
           
Annual Sum or Average 0.593108E+09 19395162.39 0.573713E+09 0.779052E+09 0.995134E+09
Minimum of Months 31466178.43 0.00 31466178.43 7187533.95 25007121.00
Maximum of Months 69718777.27 7438848.35 64335283.12 0.140193E+09 0.163646E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_2

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 31768306.86 0.00 31768306.86 11496649.33 0.140958E+09
February 35074712.83 0.00 35074712.83 23184935.65 0.110729E+09
March 50723444.73 0.00 50723444.73 45595366.48 0.104490E+09
April 56877106.67 397452.50 56479654.17 72363483.87 63138979.65
May 68462189.64 4316156.71 64146032.93 0.110201E+09 43168604.59
June 69466427.90 7294778.58 62171649.32 0.139554E+09 26101892.17
July 66929049.79 5792990.93 61136058.87 0.130022E+09 25006001.98
August 57463637.52 999121.68 56464515.84 0.102976E+09 33462148.82
September 49038597.36 18774.73 49019822.62 77612695.51 60183035.11
October 41837837.52 0.00 41837837.52 43231756.72 89368969.77
November 32728021.09 0.00 32728021.09 12823962.64 0.135146E+09
December 31464642.68 0.00 31464642.68 7186918.06 0.163644E+09
           
Annual Sum or Average 0.591834E+09 18819275.13 0.573015E+09 0.776249E+09 0.995397E+09
Minimum of Months 31464642.68 0.00 31464642.68 7186918.06 25006001.98
Maximum of Months 69466427.90 7294778.58 64146032.93 0.139554E+09 0.163644E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_3

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 31768306.86 0.00 31768306.86 11496649.33 0.140958E+09
February 35074712.83 0.00 35074712.83 23184935.65 0.110729E+09
March 50723444.73 0.00 50723444.73 45595366.48 0.104490E+09
April 56857888.59 392692.47 56465196.12 72358749.89 63178746.46
May 68462189.64 4316156.71 64146032.93 0.110201E+09 43168604.59
June 69466427.90 7294778.58 62171649.32 0.139554E+09 26101892.17
July 66929049.79 5792990.93 61136058.87 0.130022E+09 25006001.98
August 57460594.39 999061.02 56461533.36 0.102977E+09 33468330.30
September 49032324.02 18110.64 49014213.38 77615018.12 60198285.62
October 41837837.52 0.00 41837837.52 43231756.72 89368969.77
November 32728021.09 0.00 32728021.09 12823962.64 0.135146E+09
December 31464642.68 0.00 31464642.68 7186918.06 0.163644E+09
           
Annual Sum or Average 0.591805E+09 18813790.35 0.572992E+09 0.776247E+09 0.995458E+09
Minimum of Months 31464642.68 0.00 31464642.68 7186918.06 25006001.98
Maximum of Months 69466427.90 7294778.58 64146032.93 0.139554E+09 0.163644E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_4

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 31768306.86 0.00 31768306.86 11496649.33 0.140958E+09
February 35074712.83 0.00 35074712.83 23184935.65 0.110729E+09
March 50723444.73 0.00 50723444.73 45595366.48 0.104490E+09
April 56857888.59 392692.47 56465196.12 72358749.89 63178746.46
May 68462189.64 4316156.71 64146032.93 0.110201E+09 43168604.59
June 69466427.90 7294778.58 62171649.32 0.139554E+09 26101892.17
July 66929049.79 5792990.93 61136058.87 0.130022E+09 25006001.98
August 57459780.08 999094.60 56460685.48 0.102980E+09 33473269.89
September 49034412.45 18208.10 49016204.35 77629434.45 60208854.15
October 41837837.52 0.00 41837837.52 43231756.72 89368969.77
November 32728021.09 0.00 32728021.09 12823962.64 0.135146E+09
December 31464642.68 0.00 31464642.68 7186918.06 0.163644E+09
           
Annual Sum or Average 0.591807E+09 18813921.39 0.572993E+09 0.776265E+09 0.995474E+09
Minimum of Months 31464642.68 0.00 31464642.68 7186918.06 25006001.98
Maximum of Months 69466427.90 7294778.58 64146032.93 0.139554E+09 0.163644E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_5

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 31768306.86 0.00 31768306.86 11496649.33 0.140958E+09
February 35074712.83 0.00 35074712.83 23184935.65 0.110729E+09
March 50723444.73 0.00 50723444.73 45595366.48 0.104490E+09
April 56873523.97 397422.54 56476101.43 72387048.11 63170229.97
May 68462189.64 4316156.71 64146032.93 0.110201E+09 43168604.59
June 69466427.90 7294778.58 62171649.32 0.139554E+09 26101892.17
July 66929049.79 5792990.93 61136058.87 0.130022E+09 25006001.98
August 57459805.16 999148.83 56460656.33 0.102984E+09 33476565.51
September 49038426.51 18526.30 49019900.21 77643409.95 60215181.90
October 41837837.52 0.00 41837837.52 43231756.72 89368969.77
November 32728021.09 0.00 32728021.09 12823962.64 0.135146E+09
December 31464642.68 0.00 31464642.68 7186918.06 0.163644E+09
           
Annual Sum or Average 0.591826E+09 18819023.88 0.573007E+09 0.776311E+09 0.995475E+09
Minimum of Months 31464642.68 0.00 31464642.68 7186918.06 25006001.98
Maximum of Months 69466427.90 7294778.58 64146032.93 0.139554E+09 0.163644E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_6

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 31769790.51 0.00 31769790.51 11497494.57 0.140960E+09
February 35076309.13 0.00 35076309.13 23185844.49 0.110731E+09
March 50725863.42 0.00 50725863.42 45597462.35 0.104492E+09
April 56974136.01 425908.81 56548227.19 72569372.07 63126560.69
May 68795463.73 4478634.25 64316829.48 0.111018E+09 43170785.32
June 69678902.20 7413285.81 62265616.39 0.140081E+09 26103408.82
July 67142012.68 5896786.48 61245226.19 0.130539E+09 25006592.69
August 57641263.29 1070584.21 56570679.08 0.103419E+09 33477958.68
September 49042306.26 18608.42 49023697.84 77648273.29 60216961.66
October 41839675.19 0.00 41839675.19 43233116.07 89370885.97
November 32729410.41 0.00 32729410.41 12824300.52 0.135148E+09
December 31466178.35 0.00 31466178.35 7187533.91 0.163646E+09
           
Annual Sum or Average 0.592881E+09 19303807.99 0.573578E+09 0.778800E+09 0.995451E+09
Minimum of Months 31466178.35 0.00 31466178.35 7187533.91 25006592.69
Maximum of Months 69678902.20 7413285.81 64316829.48 0.140081E+09 0.163646E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_4_WALL_WEST_WINDOW_4

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 89450100.01 50634111.19 38815988.81 0.103387E+09 0.144896E+09
February 90005833.76 47741808.01 42264025.75 0.111604E+09 0.114986E+09
March 0.135208E+09 72391321.92 62816839.61 0.182343E+09 0.109983E+09
April 0.149256E+09 79685619.18 69570868.97 0.225758E+09 70656229.35
May 0.165153E+09 87025571.36 78127211.45 0.271668E+09 52178531.62
June 0.154656E+09 81246137.73 73410165.86 0.281034E+09 31442632.79
July 0.141469E+09 69002066.61 72467107.71 0.254078E+09 30158317.54
August 0.137958E+09 69215615.04 68742274.22 0.239424E+09 39271767.62
September 0.138161E+09 76435088.17 61725819.86 0.228538E+09 67071677.65
October 0.124459E+09 72603431.87 51855162.99 0.181604E+09 96348500.55
November 0.101923E+09 62204993.74 39718464.18 0.125490E+09 0.139073E+09
December 84857897.18 46433090.21 38424806.97 91666985.06 0.164943E+09
           
Annual Sum or Average 0.151256E+10 0.814619E+09 0.697939E+09 0.229660E+10 0.106101E+10
Minimum of Months 84857897.18 46433090.21 38424806.97 91666985.06 30158317.54
Maximum of Months 0.165153E+09 87025571.36 78127211.45 0.281034E+09 0.164943E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_4_WALL_WEST_WINDOW_3

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 89383202.75 50592907.31 38790295.44 0.103239E+09 0.144916E+09
February 90001464.82 47740070.19 42261394.62 0.111596E+09 0.114985E+09
March 0.135206E+09 72391238.05 62814394.88 0.182341E+09 0.109981E+09
April 0.149254E+09 79685619.18 69568673.34 0.225756E+09 70654080.84
May 0.165150E+09 87025571.36 78124925.20 0.271666E+09 52176336.38
June 0.154654E+09 81246137.73 73408270.82 0.281033E+09 31440977.31
July 0.141467E+09 69002066.61 72464872.15 0.254076E+09 30156957.40
August 0.137956E+09 69215615.04 68740110.15 0.239423E+09 39270257.95
September 0.138159E+09 76435088.17 61724002.09 0.228537E+09 67069709.01
October 0.124453E+09 72600418.98 51852191.49 0.181591E+09 96346589.05
November 0.101889E+09 62185598.84 39703756.63 0.125411E+09 0.139076E+09
December 84759880.89 46374287.46 38385593.43 91479027.30 0.165003E+09
           
Annual Sum or Average 0.151233E+10 0.814495E+09 0.697838E+09 0.229615E+10 0.106108E+10
Minimum of Months 84759880.89 46374287.46 38385593.43 91479027.30 30156957.40
Maximum of Months 0.165150E+09 87025571.36 78124925.20 0.281033E+09 0.165003E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_4_WALL_WEST_WINDOW_2

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 89383202.75 50592907.31 38790295.44 0.103239E+09 0.144916E+09
February 90001464.82 47740070.19 42261394.62 0.111596E+09 0.114985E+09
March 0.135206E+09 72391238.05 62814394.88 0.182341E+09 0.109981E+09
April 0.149254E+09 79685619.18 69568673.34 0.225756E+09 70654080.84
May 0.165150E+09 87025571.36 78124925.20 0.271666E+09 52176336.38
June 0.154654E+09 81246137.73 73408270.82 0.281033E+09 31440977.31
July 0.141467E+09 69002066.61 72464872.15 0.254076E+09 30156957.40
August 0.137956E+09 69215615.04 68740110.15 0.239423E+09 39270257.95
September 0.138159E+09 76435088.17 61724002.09 0.228537E+09 67069709.01
October 0.124453E+09 72600418.98 51852191.49 0.181591E+09 96346589.05
November 0.101889E+09 62185598.84 39703756.63 0.125411E+09 0.139076E+09
December 84759880.89 46374287.46 38385593.43 91479027.30 0.165003E+09
           
Annual Sum or Average 0.151233E+10 0.814495E+09 0.697838E+09 0.229615E+10 0.106108E+10
Minimum of Months 84759880.89 46374287.46 38385593.43 91479027.30 30156957.40
Maximum of Months 0.165150E+09 87025571.36 78124925.20 0.281033E+09 0.165003E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_4_WALL_WEST_WINDOW_1

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 89384686.47 50592907.31 38791779.16 0.103240E+09 0.144918E+09
February 90003061.20 47740070.19 42262991.01 0.111597E+09 0.114987E+09
March 0.135208E+09 72391238.05 62816813.70 0.182343E+09 0.109983E+09
April 0.149256E+09 79685619.18 69570869.08 0.225758E+09 70656229.46
May 0.165153E+09 87025571.36 78127211.57 0.271668E+09 52178531.73
June 0.154656E+09 81246137.73 73410165.96 0.281034E+09 31442632.87
July 0.141469E+09 69002066.61 72467107.83 0.254078E+09 30158317.61
August 0.137958E+09 69215615.04 68742274.33 0.239424E+09 39271767.69
September 0.138161E+09 76435088.17 61725819.96 0.228538E+09 67071677.75
October 0.124454E+09 72600418.98 51854029.25 0.181593E+09 96348500.65
November 0.101891E+09 62185598.84 39705146.02 0.125412E+09 0.139078E+09
December 84761416.64 46374287.46 38387129.18 91479679.47 0.165005E+09
           
Annual Sum or Average 0.151236E+10 0.814495E+09 0.697861E+09 0.229616E+10 0.106110E+10
Minimum of Months 84761416.64 46374287.46 38387129.18 91479679.47 30158317.61
Maximum of Months 0.165153E+09 87025571.36 78127211.57 0.281034E+09 0.165005E+09



Table of Contents

Report: WindowZoneSummaryMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 863.12 401.73 622.60 474.24 148.36 0.00 0.00
February 820.36 351.10 576.64 409.36 167.29 0.00 0.00
March 615.58 301.29 423.83 236.58 187.26 0.00 0.00
April 336.66 191.89 226.64 52.39 174.25 0.00 0.00
May 278.70 125.75 172.16 0.79 171.37 0.00 0.00
June 342.82 75.69 168.62 0.00 168.62 0.00 0.00
July 316.45 71.20 162.00 0.60 161.40 0.00 0.00
August 323.99 98.29 177.63 18.39 159.24 0.00 0.00
September 565.16 183.96 321.80 150.04 171.76 0.00 0.00
October 812.21 262.21 519.93 351.71 168.21 0.00 0.00
November 911.71 385.99 643.68 493.21 150.46 0.00 0.00
December 862.12 446.03 637.65 481.27 156.38 0.00 0.00
               
Annual Sum or Average 586.02 240.71 386.73 221.38 165.36 0.00 0.00
Minimum of Months 278.70 71.20 162.00 0.00 148.36 0.00 0.00
Maximum of Months 911.71 446.03 643.68 493.21 187.26 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 133.00 202.17 126.35 68.84 57.51 0.00 0.00
February 204.10 176.85 168.59 96.30 72.29 0.00 0.00
March 267.59 150.31 205.81 113.13 92.69 0.00 0.00
April 364.84 97.20 246.91 135.77 111.14 0.00 0.00
May 409.88 67.33 253.21 135.87 117.34 0.00 0.00
June 451.48 41.72 252.05 137.73 114.32 0.00 0.00
July 400.40 39.19 226.36 116.89 109.47 0.00 0.00
August 368.97 51.91 215.83 108.93 106.91 0.00 0.00
September 346.80 91.00 216.45 122.81 93.64 0.00 0.00
October 231.00 131.50 167.53 90.21 77.32 0.00 0.00
November 169.22 199.12 151.80 88.51 63.28 0.00 0.00
December 123.17 232.22 126.54 67.49 59.05 0.00 0.00
               
Annual Sum or Average 289.42 123.12 196.46 106.80 89.66 0.00 0.00
Minimum of Months 123.17 39.19 126.35 67.49 57.51 0.00 0.00
Maximum of Months 451.48 232.22 253.21 137.73 117.34 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 25.75 315.77 71.17 0.00 71.17 0.00 0.00
February 57.50 274.63 86.99 0.00 86.99 0.00 0.00
March 102.14 234.07 113.63 0.00 113.63 0.00 0.00
April 167.60 146.09 131.73 0.94 130.79 0.00 0.00
May 247.50 96.69 153.63 9.80 143.83 0.00 0.00
June 323.49 60.42 160.98 16.99 143.99 0.00 0.00
July 291.72 56.02 150.11 13.07 137.05 0.00 0.00
August 231.05 74.98 128.88 2.30 126.58 0.00 0.00
September 179.69 139.35 113.51 0.04 113.47 0.00 0.00
October 96.85 200.20 93.72 0.00 93.72 0.00 0.00
November 29.69 312.84 75.76 0.00 75.76 0.00 0.00
December 16.10 366.59 70.49 0.00 70.49 0.00 0.00
               
Annual Sum or Average 147.86 189.38 112.67 3.61 109.06 0.00 0.00
Minimum of Months 16.10 56.02 70.49 0.00 70.49 0.00 0.00
Maximum of Months 323.49 366.59 160.98 16.99 143.99 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 154.24 216.41 133.51 75.57 57.94 0.00 0.00
February 184.52 190.12 148.81 78.94 69.88 0.00 0.00
March 272.31 164.25 201.92 108.11 93.81 0.00 0.00
April 348.39 109.04 230.33 122.97 107.36 0.00 0.00
May 405.72 77.92 246.64 129.97 116.68 0.00 0.00
June 433.69 48.52 238.67 125.38 113.29 0.00 0.00
July 379.45 45.04 211.27 103.05 108.22 0.00 0.00
August 357.56 58.65 206.03 103.37 102.66 0.00 0.00
September 352.68 103.50 213.21 117.96 95.25 0.00 0.00
October 271.20 143.89 185.86 108.42 77.44 0.00 0.00
November 193.57 214.62 157.25 95.97 61.28 0.00 0.00
December 136.69 246.40 126.62 69.28 57.34 0.00 0.00
               
Annual Sum or Average 291.26 134.58 191.83 103.31 88.52 0.00 0.00
Minimum of Months 136.69 45.04 126.62 69.28 57.34 0.00 0.00
Maximum of Months 433.69 246.40 246.64 129.97 116.68 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: ATTIC

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.231178E+10 0.107600E+10 0.166758E+10 0.127020E+10 0.397372E+09 0.00 0.00
February 0.198461E+10 0.849370E+09 0.139502E+10 0.990315E+09 0.404702E+09 0.00 0.00
March 0.164878E+10 0.806969E+09 0.113519E+10 0.633648E+09 0.501546E+09 0.00 0.00
April 0.872617E+09 0.497378E+09 0.587463E+09 0.135798E+09 0.451665E+09 0.00 0.00
May 0.746473E+09 0.336820E+09 0.461115E+09 2111780.74 0.459003E+09 0.00 0.00
June 0.888577E+09 0.196200E+09 0.437052E+09 0.11 0.437052E+09 0.00 0.00
July 0.847589E+09 0.190710E+09 0.433896E+09 1599757.94 0.432297E+09 0.00 0.00
August 0.867768E+09 0.263269E+09 0.475762E+09 49254300.50 0.426507E+09 0.00 0.00
September 0.146489E+10 0.476822E+09 0.834102E+09 0.388896E+09 0.445206E+09 0.00 0.00
October 0.217542E+10 0.702293E+09 0.139257E+10 0.942032E+09 0.450542E+09 0.00 0.00
November 0.236316E+10 0.100050E+10 0.166841E+10 0.127840E+10 0.390005E+09 0.00 0.00
December 0.230910E+10 0.119465E+10 0.170788E+10 0.128903E+10 0.418852E+09 0.00 0.00
               
Annual Sum or Average 0.184808E+11 0.759098E+10 0.121960E+11 0.698129E+10 0.521475E+10 0.00 0.00
Minimum of Months 0.746473E+09 0.190710E+09 0.433896E+09 0.11 0.390005E+09 0.00 0.00
Maximum of Months 0.236316E+10 0.119465E+10 0.170788E+10 0.128903E+10 0.501546E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.356234E+09 0.541496E+09 0.338418E+09 0.184378E+09 0.154040E+09 0.00 0.00
February 0.493766E+09 0.427844E+09 0.407843E+09 0.232957E+09 0.174886E+09 0.00 0.00
March 0.716706E+09 0.402598E+09 0.551251E+09 0.302996E+09 0.248255E+09 0.00 0.00
April 0.945661E+09 0.251951E+09 0.640004E+09 0.351926E+09 0.288078E+09 0.00 0.00
May 0.109782E+10 0.180345E+09 0.678191E+09 0.363913E+09 0.314278E+09 0.00 0.00
June 0.117023E+10 0.108148E+09 0.653322E+09 0.357007E+09 0.296315E+09 0.00 0.00
July 0.107243E+10 0.104975E+09 0.606283E+09 0.313068E+09 0.293215E+09 0.00 0.00
August 0.988236E+09 0.139033E+09 0.578088E+09 0.291748E+09 0.286340E+09 0.00 0.00
September 0.898909E+09 0.235874E+09 0.561042E+09 0.318326E+09 0.242716E+09 0.00 0.00
October 0.618699E+09 0.352220E+09 0.448725E+09 0.241623E+09 0.207102E+09 0.00 0.00
November 0.438609E+09 0.516125E+09 0.393455E+09 0.229426E+09 0.164029E+09 0.00 0.00
December 0.329889E+09 0.621991E+09 0.338937E+09 0.180775E+09 0.158161E+09 0.00 0.00
               
Annual Sum or Average 0.912719E+10 0.388260E+10 0.619556E+10 0.336814E+10 0.282741E+10 0.00 0.00
Minimum of Months 0.329889E+09 0.104975E+09 0.338418E+09 0.180775E+09 0.154040E+09 0.00 0.00
Maximum of Months 0.117023E+10 0.621991E+09 0.678191E+09 0.363913E+09 0.314278E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 68981586.51 0.845754E+09 0.190613E+09 0.00 0.190613E+09 0.00 0.00
February 0.139111E+09 0.664379E+09 0.210451E+09 0.00 0.210451E+09 0.00 0.00
March 0.273576E+09 0.626942E+09 0.304346E+09 0.00 0.304346E+09 0.00 0.00
April 0.434430E+09 0.378667E+09 0.341449E+09 2435774.13 0.339013E+09 0.00 0.00
May 0.662894E+09 0.258980E+09 0.411474E+09 26238039.09 0.385236E+09 0.00 0.00
June 0.838491E+09 0.156614E+09 0.417263E+09 44031248.47 0.373232E+09 0.00 0.00
July 0.781334E+09 0.150038E+09 0.402066E+09 34999647.68 0.367066E+09 0.00 0.00
August 0.618854E+09 0.200814E+09 0.345179E+09 6149162.33 0.339030E+09 0.00 0.00
September 0.465763E+09 0.361204E+09 0.294228E+09 111109.41 0.294117E+09 0.00 0.00
October 0.259393E+09 0.536218E+09 0.251031E+09 0.00 0.251031E+09 0.00 0.00
November 76944451.63 0.810882E+09 0.196371E+09 0.00 0.196371E+09 0.00 0.00
December 43122740.09 0.981869E+09 0.188791E+09 0.00 0.188791E+09 0.00 0.00
               
Annual Sum or Average 0.466290E+10 0.597236E+10 0.355326E+10 0.113965E+09 0.343930E+10 0.00 0.00
Minimum of Months 43122740.09 0.150038E+09 0.188791E+09 0.00 0.188791E+09 0.00 0.00
Maximum of Months 0.838491E+09 0.981869E+09 0.417263E+09 44031248.47 0.385236E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.413103E+09 0.579644E+09 0.357601E+09 0.202413E+09 0.155188E+09 0.00 0.00
February 0.446394E+09 0.459942E+09 0.360012E+09 0.190962E+09 0.169050E+09 0.00 0.00
March 0.729368E+09 0.439929E+09 0.540827E+09 0.289565E+09 0.251262E+09 0.00 0.00
April 0.903028E+09 0.282621E+09 0.597022E+09 0.318742E+09 0.278279E+09 0.00 0.00
May 0.108667E+10 0.208710E+09 0.660607E+09 0.348102E+09 0.312504E+09 0.00 0.00
June 0.112413E+10 0.125767E+09 0.618621E+09 0.324985E+09 0.293637E+09 0.00 0.00
July 0.101631E+10 0.120631E+09 0.565872E+09 0.276008E+09 0.289864E+09 0.00 0.00
August 0.957694E+09 0.157084E+09 0.551827E+09 0.276862E+09 0.274965E+09 0.00 0.00
September 0.914151E+09 0.268283E+09 0.552640E+09 0.305740E+09 0.246900E+09 0.00 0.00
October 0.726379E+09 0.385390E+09 0.497818E+09 0.290405E+09 0.207414E+09 0.00 0.00
November 0.501724E+09 0.556305E+09 0.407593E+09 0.248762E+09 0.158831E+09 0.00 0.00
December 0.366097E+09 0.659946E+09 0.339139E+09 0.185556E+09 0.153583E+09 0.00 0.00
               
Annual Sum or Average 0.918505E+10 0.424425E+10 0.604958E+10 0.325810E+10 0.279148E+10 0.00 0.00
Minimum of Months 0.366097E+09 0.120631E+09 0.339139E+09 0.185556E+09 0.153583E+09 0.00 0.00
Maximum of Months 0.112413E+10 0.659946E+09 0.660607E+09 0.348102E+09 0.312504E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: ATTIC

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AverageOutdoorConditionsMonthly

For: Environment

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] SITE OUTDOOR AIR WETBULB TEMPERATURE [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] SITE WIND SPEED [m/s] SITE SKY TEMPERATURE [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] SITE RAIN STATUS []
January 8.14 3.28 -3.0 3.49 -5.4 41.12 223.64 0.00
February 10.27 3.71 -4.6 3.82 -5.0 51.61 245.22 0.00
March 12.55 4.68 -5.5 4.62 -3.1 72.41 273.25 0.00
April 19.23 8.50 -2.7 4.72 3.38 79.21 314.56 0.00
May 23.84 12.23 2.64 5.25 8.38 86.83 326.20 0.00
June 27.86 15.03 5.88 4.15 14.09 80.19 344.14 0.01
July 27.54 18.92 14.64 3.53 17.44 86.25 283.04 0.01
August 26.28 17.11 12.00 3.28 15.48 80.55 269.68 0.02
September 23.38 15.82 11.20 2.23 11.29 66.71 294.09 0.00
October 18.30 12.02 7.27 3.24 6.21 54.59 257.93 0.01
November 11.18 5.22 -1.5 3.40 -3.3 40.23 258.80 0.00
December 6.79 1.84 -4.8 2.82 -8.9 42.65 217.21 0.00
                 
Annual Sum or Average 17.98 9.90 2.67 3.71 4.26 65.29 275.60 0.00
Minimum of Months 6.79 1.84 -5.5 2.23 -8.9 40.23 217.21 0.00
Maximum of Months 27.86 18.92 14.64 5.25 17.44 86.83 344.14 0.02



Table of Contents

Report: OutdoorConditionsMaximumDryBulbMonthly

For: Environment

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] SITE WIND SPEED {AT MAX/MIN} [m/s] SITE SKY TEMPERATURE {AT MAX/MIN} [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2]
January 20.60 03-JAN-14:00 8.39 -5.0 9.80 2.22 118.50 530.50
February 23.30 20-FEB-14:00 8.88 -7.8 4.10 4.10 55.00 955.00
March 25.00 21-MAR-15:00 9.53 -8.3 6.20 5.54 50.00 873.00
April 32.20 21-APR-13:00 15.21 2.80 13.90 18.28 265.50 638.50
May 35.00 19-MAY-13:00 17.23 6.10 10.30 21.78 145.00 874.50
June 38.90 02-JUN-15:00 16.22 -1.1 4.60 20.40 234.50 284.00
July 38.30 01-JUL-16:00 19.19 8.90 3.60 26.81 165.50 256.50
August 37.20 07-AUG-15:00 17.89 6.70 5.70 24.66 143.50 615.00
September 33.90 19-SEP-13:00 16.85 6.70 3.10 17.75 113.00 912.00
October 32.80 01-OCT-14:00 15.90 4.40 5.70 16.12 127.50 736.50
November 23.90 03-NOV-15:00 13.45 6.10 5.70 12.22 48.50 648.50
December 18.30 10-DEC-14:00 7.97 -2.8 7.20 4.10 123.00 52.50
                 
Annual Sum or Average                
Minimum of Months 18.30   7.97 -8.3 3.10 2.22 48.50 52.50
Maximum of Months 38.90   19.19 8.90 13.90 26.81 265.50 955.00



Table of Contents

Report: OutdoorConditionsMinimumDryBulbMonthly

For: Environment

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] SITE WIND SPEED {AT MAX/MIN} [m/s] SITE SKY TEMPERATURE {AT MAX/MIN} [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2]
January -4.4 27-JAN-06:00 -7.5 -15.0 3.60 -23.6 0.00 0.00
February -5.6 03-FEB-06:00 -7.5 -11.7 1.50 -23.9 0.00 0.00
March -3.9 02-MAR-04:00 -6.5 -12.8 1.50 -21.3 0.00 0.00
April 3.30 12-APR-05:00 -1.8 -9.4 2.10 -14.9 37.00 217.50
May 9.40 02-MAY-05:00 3.98 -2.2 3.60 -7.6 51.00 277.50
June 15.00 13-JUN-04:00 4.43 -10.6 2.10 -4.3 0.00 0.00
July 17.80 05-JUL-05:00 15.98 15.00 4.10 4.31 39.00 249.00
August 16.70 31-AUG-05:00 13.89 12.20 4.10 2.64 36.00 126.50
September 8.30 30-SEP-05:00 5.77 3.30 1.50 -7.3 0.00 0.00
October 6.70 11-OCT-05:00 5.82 5.00 1.50 -5.5 0.00 0.00
November -0.6 17-NOV-03:00 -3.1 -6.7 1.50 -18.1 0.00 0.00
December -4.4 27-DEC-06:00 -5.1 -6.1 2.10 -18.6 0.00 0.00
                 
Annual Sum or Average                
Minimum of Months -5.6   -7.5 -15.0 1.50 -23.9 0.00 0.00
Maximum of Months 17.80   15.98 15.00 4.10 4.31 51.00 277.50



Table of Contents

Report: OutdoorConditionsMaximumWetBulbMonthly

For: Environment

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] SITE WIND SPEED {AT MAX/MIN} [m/s] SITE SKY TEMPERATURE {AT MAX/MIN} [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2]
January 10.18 12-JAN-15:00 18.90 2.80 3.60 6.15 70.50 491.50
February 11.42 13-FEB-16:00 12.80 10.60 4.10 6.55 34.00 18.50
March 10.75 10-MAR-18:00 13.30 8.90 1.50 8.54 0.00 0.00
April 15.74 29-APR-13:00 30.00 6.70 4.10 18.28 336.50 432.50
May 19.12 24-MAY-12:00 27.80 15.00 5.20 17.57 188.50 862.00
June 20.21 03-JUN-14:00 33.90 13.90 8.80 23.66 264.50 316.00
July 22.88 20-JUL-15:39 25.53 21.87 2.93 18.99 184.00 15.83
August 21.18 02-AUG-11:00 30.60 17.20 3.60 20.75 154.50 850.00
September 20.65 14-SEP-09:00 25.00 18.90 2.10 14.47 126.50 835.50
October 19.64 03-OCT-13:00 32.80 13.30 2.60 21.44 224.50 577.50
November 13.57 03-NOV-14:00 23.30 7.20 0.00 10.88 72.50 802.00
December 8.30 10-DEC-12:00 17.20 -0.6 5.70 1.58 198.50 507.50
                 
Annual Sum or Average                
Minimum of Months 8.30   12.80 -0.6 0.00 1.58 0.00 0.00
Maximum of Months 22.88   33.90 21.87 8.80 23.66 336.50 862.00



Table of Contents

Report: OutdoorConditionsMaximumDewPointMonthly

For: Environment

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] SITE WIND SPEED {AT MAX/MIN} [m/s] SITE SKY TEMPERATURE {AT MAX/MIN} [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2]
January 9.00 16-JAN-01:00 9.00 9.00 2.10 4.51 0.00 0.00
February 10.60 13-FEB-13:09 12.20 11.24 5.53 5.71 147.33 0.00
March 10.00 11-MAR-00:00 10.60 10.24 2.10 6.15 0.00 0.00
April 10.60 17-APR-01:00 17.80 13.38 7.20 3.48 0.00 0.00
May 15.00 24-MAY-10:00 25.60 18.41 7.20 15.39 171.00 872.50
June 17.20 19-JUN-17:00 23.90 19.20 3.60 15.39 86.00 324.00
July 22.20 20-JUL-14:00 24.40 22.82 4.60 17.93 283.00 59.50
August 18.90 01-AUG-20:00 22.20 19.91 4.60 17.75 0.00 0.00
September 19.40 22-SEP-01:00 20.60 19.76 1.50 16.30 0.00 0.00
October 17.20 03-OCT-19:00 23.30 19.11 4.60 18.46 0.00 0.00
November 10.00 01-NOV-09:00 13.30 11.28 3.10 8.94 123.50 0.00
December 6.10 13-DEC-00:00 8.30 7.10 7.70 3.06 0.00 0.00
                 
Annual Sum or Average                
Minimum of Months 6.10   8.30 7.10 1.50 3.06 0.00 0.00
Maximum of Months 22.20   25.60 22.82 7.70 18.46 283.00 872.50



Table of Contents

Report: OutdoorGroundConditionsMonthly

For: Environment

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SITE GROUND TEMPERATURE [C] SITE SURFACE GROUND TEMPERATURE [C] SITE DEEP GROUND TEMPERATURE [C] SITE MAINS WATER TEMPERATURE [C] SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] SITE SNOW ON GROUND STATUS []
January 18.00 13.00 16.00 15.16 28.38 0.00
February 18.00 13.00 16.00 15.21 35.58 0.00
March 18.00 13.00 16.00 16.80 47.71 0.00
April 18.00 13.00 16.00 19.62 58.45 0.00
May 18.00 13.00 16.00 22.88 63.58 0.00
June 18.00 13.00 16.00 25.71 66.73 0.00
July 18.00 13.00 16.00 27.35 58.19 0.00
August 18.00 13.00 16.00 27.33 54.44 0.00
September 18.00 13.00 16.00 25.68 50.89 0.00
October 18.00 13.00 16.00 22.83 39.37 0.00
November 18.00 13.00 16.00 19.57 32.11 0.00
December 18.00 13.00 16.00 16.77 26.90 0.00
             
Annual Sum or Average 18.00 13.00 16.00 21.28 46.90 0.00
Minimum of Months 18.00 13.00 16.00 15.16 26.90 0.00
Maximum of Months 18.00 13.00 16.00 27.35 66.73 0.00



Table of Contents

Report: WaterHeaterReportMonthly

For: SWHSYS1 WATER HEATER

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] WATER HEATER BURNER HEATING ENERGY [] WATER HEATER GAS CONSUMPTION [] WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] WATER HEATER LOSS DEMAND ENERGY [] WATER HEATER HEAT LOSS ENERGY [J] WATER HEATER TANK TEMPERATURE [C] WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] WATER HEATER SOURCE ENERGY []
January 0.518385E+09 -445576230.6 0.00 0.00 744.00 0.00 -72808824.1 59.00 0.00 0.00
February 0.467822E+09 -402876056.8 0.00 0.00 672.00 0.00 -64946030.5 59.00 0.00 0.00
March 0.539885E+09 -469451834.0 0.00 0.00 744.00 0.00 -70433449.2 58.98 0.00 0.00
April 0.446538E+09 -381263359.6 0.00 0.00 720.00 0.00 -65274857.1 59.00 0.00 0.00
May 0.451152E+09 -385672152.4 0.00 0.00 744.00 0.00 -65479510.8 58.99 0.00 0.00
June 0.416199E+09 -353996363.3 0.00 0.00 720.00 0.00 -62202742.6 59.00 0.00 0.00
July 0.369515E+09 -306067128.3 0.00 0.00 744.00 0.00 -63447749.6 58.99 0.00 0.00
August 0.416633E+09 -352580898.4 0.00 0.00 744.00 0.00 -64052378.8 58.99 0.00 0.00
September 0.385312E+09 -323157880.3 0.00 0.00 720.00 0.00 -62154276.9 59.00 0.00 0.00
October 0.433955E+09 -367921495.8 0.00 0.00 744.00 0.00 -66034000.4 59.00 0.00 0.00
November 0.467152E+09 -400623805.4 0.00 0.00 720.00 0.00 -66527834.1 58.99 0.00 0.00
December 0.480933E+09 -408404494.0 0.00 0.00 744.00 0.00 -72528846.0 58.99 0.00 0.00
                     
Annual Sum or Average 0.539348E+10 -0.459759E+10 0.00 0.00 8760.00 0.00 -795890500.1 58.99 0.00 0.00
Minimum of Months 0.369515E+09 -469451834.0 0.00 0.00 672.00 0.00 -72808824.1 58.98 0.00 0.00
Maximum of Months 0.539885E+09 -306067128.3 0.00 0.00 744.00 0.00 -62154276.9 59.00 0.00 0.00



Table of Contents

Report: DaylightingReportMonthly

For: PERIMETER_ZN_1_DAYLCTRL

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 276.83 0.74 0.73 01-JAN-08:39 2016.85 28.43 156.83 250.83 671.77 26.15 194.33 231.00
February 268.33 0.76 0.73 01-FEB-08:30 2701.10 26.71 139.17 218.00 477.08 21.49 143.67 182.17
March 351.83 0.78 0.73 01-MAR-07:00 536.35 16.87 5.67 222.00 345.11 20.79 143.83 169.83
April 373.83 0.80 0.73 01-APR-09:00 305.30 16.08 0.00 109.67 229.50 20.26 115.67 34.17
May 408.83 0.83 0.73 13-MAY-09:00 250.53 15.45 0.00 35.67 187.21 19.63 72.83 0.00
June 398.00 0.84 0.73 30-JUN-12:30 227.20 15.20 0.00 12.67 173.10 19.54 31.67 0.00
July 400.17 0.83 0.73 03-JUL-10:20 240.03 15.28 0.00 42.00 180.02 19.52 73.83 0.00
August 377.83 0.81 0.73 01-AUG-10:00 281.72 15.89 0.00 80.50 209.27 20.05 110.33 15.50
September 365.83 0.79 0.73 01-SEP-10:20 363.08 16.15 0.00 166.00 277.84 20.34 131.00 105.33
October 318.83 0.76 0.73 01-OCT-07:49 823.63 18.28 22.67 256.67 428.41 21.51 147.17 194.67
November 295.83 0.75 0.73 02-NOV-09:39 2073.21 27.10 160.17 251.67 519.74 23.14 158.00 214.17
December 289.50 0.75 0.73 01-DEC-07:30 1721.81 27.70 156.67 252.83 746.96 24.66 203.83 220.67
                         
Annual Sum or Average 4125.67 0.79     845.57 19.21 641.17 1898.50 345.64 21.18 1526.17 1367.50
Minimum of Months 268.33 0.74 0.73   227.20 15.20 0.00 12.67 173.10 19.52 31.67 0.00
Maximum of Months 408.83 0.84 0.73   2701.10 28.43 160.17 256.67 746.96 26.15 203.83 231.00



Table of Contents

Report: DaylightingReportMonthly

For: PERIMETER_ZN_2_DAYLCTRL

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 276.83 0.84 0.73 01-JAN-08:39 1393.26 19.95 78.83 89.50 782.61 23.10 88.17 71.83
February 268.33 0.83 0.73 01-FEB-08:09 1064.43 17.53 44.67 88.00 485.96 21.83 88.33 77.00
March 351.83 0.83 0.73 01-MAR-07:40 347.14 14.08 1.83 120.17 275.47 19.06 73.50 87.33
April 373.83 0.83 0.73 01-APR-06:40 324.12 14.00 0.00 126.00 290.28 19.24 86.83 107.67
May 408.83 0.83 0.73 01-MAY-06:19 312.98 13.94 0.00 126.67 285.49 19.25 104.17 117.00
June 398.00 0.83 0.73 01-JUN-06:10 305.22 13.98 0.00 122.67 281.55 19.42 90.17 112.83
July 400.17 0.83 0.73 01-JUL-06:10 296.92 13.98 0.00 122.83 268.56 19.31 98.67 109.83
August 377.83 0.83 0.73 01-AUG-06:19 306.23 14.15 0.00 116.33 273.36 19.36 100.83 103.00
September 365.83 0.83 0.73 01-SEP-06:49 292.93 13.70 0.00 111.33 299.23 19.20 67.17 94.17
October 318.83 0.84 0.73 01-OCT-06:00 421.27 14.59 7.33 102.33 663.09 21.81 90.50 82.83
November 295.83 0.84 0.73 02-NOV-09:50 871.99 17.10 49.50 87.00 575.16 22.50 84.00 73.67
December 289.50 0.83 0.73 01-DEC-07:49 858.84 18.65 61.83 92.83 368.02 21.62 92.17 70.50
                         
Annual Sum or Average 4125.67 0.83     520.32 15.21 244.00 1305.67 385.29 20.29 1064.50 1107.67
Minimum of Months 268.33 0.83 0.73   292.93 13.70 0.00 87.00 268.56 19.06 67.17 70.50
Maximum of Months 408.83 0.84 0.73   1393.26 19.95 78.83 126.67 782.61 23.10 104.17 117.00



Table of Contents

Report: DaylightingReportMonthly

For: PERIMETER_ZN_3_DAYLCTRL

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 276.83 0.92 0.85 25-JAN-11:30 115.37 11.85 0.00 0.00 89.81 16.27 0.00 0.00
February 268.33 0.91 0.83 28-FEB-13:30 132.63 12.64 0.00 0.00 101.63 16.88 0.00 0.00
March 351.83 0.89 0.78 24-MAR-13:30 157.41 13.53 0.00 0.00 115.49 17.49 0.00 0.00
April 373.83 0.87 0.74 25-APR-08:30 189.48 14.80 0.00 0.00 135.97 18.62 0.00 0.00
May 408.83 0.84 0.74 31-MAY-07:49 227.29 15.66 0.00 2.00 157.71 19.33 3.33 0.00
June 398.00 0.83 0.74 20-JUN-15:30 238.23 16.03 0.00 5.00 165.19 19.77 8.17 0.00
July 400.17 0.84 0.74 22-JUL-16:30 232.95 15.89 0.00 5.17 159.88 19.58 5.00 0.00
August 377.83 0.85 0.74 02-AUG-15:30 212.21 15.18 0.00 6.50 143.98 18.94 0.33 0.00
September 365.83 0.89 0.80 15-SEP-14:50 159.73 13.86 0.00 0.00 117.55 17.80 0.00 0.00
October 318.83 0.90 0.82 02-OCT-09:50 139.93 12.97 0.00 0.00 105.85 17.10 0.00 0.00
November 295.83 0.92 0.85 02-NOV-10:30 111.73 11.78 0.00 0.00 87.19 16.17 0.00 0.00
December 289.50 0.92 0.86 14-DEC-12:30 115.82 11.90 0.00 0.00 89.58 16.26 0.00 0.00
                         
Annual Sum or Average 4125.67 0.88     175.61 14.05 0.00 18.67 126.20 18.03 16.83 0.00
Minimum of Months 268.33 0.83 0.74   111.73 11.78 0.00 0.00 87.19 16.17 0.00 0.00
Maximum of Months 408.83 0.92 0.86   238.23 16.03 0.00 6.50 165.19 19.77 8.17 0.00



Table of Contents

Report: DaylightingReportMonthly

For: PERIMETER_ZN_4_DAYLCTRL

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 276.83 0.83 0.73 01-JAN-14:09 839.58 18.25 53.83 89.00 564.31 23.60 93.50 72.67
February 268.33 0.83 0.73 01-FEB-14:20 923.55 17.80 47.83 81.50 580.78 21.98 77.00 62.17
March 351.83 0.83 0.73 01-MAR-13:00 340.96 14.36 1.83 114.33 276.25 19.16 77.50 88.50
April 373.83 0.83 0.73 01-APR-13:00 307.80 14.20 0.00 116.83 270.13 19.33 72.67 98.50
May 408.83 0.83 0.73 01-MAY-13:20 303.60 14.20 0.00 123.50 272.09 19.48 89.83 110.17
June 398.00 0.83 0.73 01-JUN-14:09 292.75 14.29 0.00 113.50 264.90 19.60 75.17 101.67
July 400.17 0.83 0.73 01-JUL-13:30 283.72 14.32 0.00 110.50 251.18 19.53 84.17 94.17
August 377.83 0.83 0.73 01-AUG-13:20 295.11 14.28 0.00 109.83 258.37 19.35 77.67 95.50
September 365.83 0.84 0.73 01-SEP-13:50 296.46 13.97 0.00 114.50 305.90 19.33 84.33 94.33
October 318.83 0.83 0.73 01-OCT-13:30 407.83 15.00 7.33 106.17 623.48 22.45 90.67 91.50
November 295.83 0.84 0.73 01-NOV-15:20 824.16 17.88 53.17 81.33 436.88 22.17 79.00 74.33
December 289.50 0.84 0.73 01-DEC-13:39 674.27 18.18 52.83 83.67 371.80 22.49 90.83 63.67
                         
Annual Sum or Average 4125.67 0.83     450.46 15.33 216.83 1244.67 356.94 20.50 992.33 1047.17
Minimum of Months 268.33 0.83 0.73   283.72 13.97 0.00 81.33 251.18 19.16 72.67 62.17
Maximum of Months 408.83 0.84 0.73   923.55 18.25 53.83 123.50 623.48 23.60 93.50 110.17



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:1 HEATING COIL

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 14706711.42 5315.08 17-JAN-08:62 0.00 0.00 0.00 0.00 0.00
February 4278985.47 3619.59 02-FEB-08:62 0.00 0.00 0.00 0.00 0.00
March 859105.75 3751.23 02-MAR-08:62 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 32713003.91 4772.30 05-DEC-08:62 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 52557806.54     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 32713003.91 5315.08   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:2 HEATING COIL

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.277000E+09 5909.14 18-JAN-07:03 0.00 0.00 0.00 0.00 0.00
February 0.196684E+09 6685.24 14-FEB-08:62 0.00 0.00 0.00 0.00 0.00
March 0.207019E+09 6800.48 06-MAR-08:61 0.00 0.00 0.00 0.00 0.00
April 22223470.42 6530.96 13-APR-07:01 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 53833434.32 5548.05 17-NOV-08:62 0.00 0.00 0.00 0.00 0.00
December 0.296076E+09 5268.63 05-DEC-08:62 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.105283E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.296076E+09 6800.48   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:3 HEATING COIL

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.136172E+09 4311.35 18-JAN-07:02 0.00 0.00 0.00 0.00 0.00
February 71562637.75 4446.89 06-FEB-07:02 0.00 0.00 0.00 0.00 0.00
March 46507666.05 4517.74 03-MAR-07:02 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 10121255.53 3439.02 28-NOV-08:62 0.00 0.00 0.00 0.00 0.00
December 0.151328E+09 4336.92 20-DEC-07:02 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.415691E+09     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.151328E+09 4517.74   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:4 HEATING COIL

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.509578E+09 6304.27 31-JAN-08:62 0.00 0.00 0.00 0.00 0.00
February 0.344126E+09 6598.21 14-FEB-08:62 0.00 0.00 0.00 0.00 0.00
March 0.197706E+09 6711.95 06-MAR-08:61 0.00 0.00 0.00 0.00 0.00
April 1013396.25 4898.89 12-APR-07:02 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 43711699.15 6185.36 20-NOV-08:62 0.00 0.00 0.00 0.00 0.00
December 0.504876E+09 5945.72 20-DEC-08:62 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.160101E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.509578E+09 6711.95   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:5 HEATING COIL

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.168267E+09 5212.81 18-JAN-07:02 0.00 0.00 0.00 0.00 0.00
February 0.119375E+09 5376.69 06-FEB-07:02 0.00 0.00 0.00 0.00 0.00
March 59789850.31 5999.11 06-MAR-08:61 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 10097832.22 3590.48 28-NOV-08:62 0.00 0.00 0.00 0.00 0.00
December 0.183396E+09 4624.97 05-DEC-08:62 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.540925E+09     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.183396E+09 5999.11   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:1_SUPPHEATCOIL

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 1423115.07 3065.23 27-JAN-08:62 0.00 0.00 0.00 0.00 0.00
February 851143.88 3059.19 03-FEB-08:62 0.00 0.00 0.00 0.00 0.00
March 281589.27 1877.26 02-MAR-08:62 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00
December 3606247.94 3065.23 04-DEC-08:62 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 6162096.17     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 3606247.94 3065.23   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:2_SUPPHEATCOIL

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 12234974.43 4691.77 10-JAN-07:02 0.00 0.00 0.00 0.00 0.00
February 22935181.71 4691.77 01-FEB-07:01 0.00 0.00 0.00 0.00 0.00
March 8145938.48 4691.77 01-MAR-07:02 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 612053.72 4691.77 28-NOV-07:02 0.00 0.00 0.00 0.00 0.00
December 33336970.24 4691.77 04-DEC-07:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 77265118.57     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 33336970.24 4691.77   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:3_SUPPHEATCOIL

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 4597483.09 2933.47 02-JAN-07:02 0.00 0.00 0.00 0.00 0.00
February 3474826.46 2933.47 01-FEB-07:01 0.00 0.00 0.00 0.00 0.00
March 1451426.85 2933.47 01-MAR-07:02 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 293346.58 2933.47 28-NOV-07:02 0.00 0.00 0.00 0.00 0.00
December 5486600.65 2933.47 04-DEC-07:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 15303683.63     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 5486600.65 2933.47   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:4_SUPPHEATCOIL

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 11998703.23 4663.87 02-JAN-07:02 0.00 0.00 0.00 0.00 0.00
February 10142947.16 4663.87 01-FEB-07:01 0.00 0.00 0.00 0.00 0.00
March 4634663.77 4663.87 01-MAR-07:02 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 1078360.28 4663.87 28-NOV-07:02 0.00 0.00 0.00 0.00 0.00
December 16935951.29 4663.87 04-DEC-07:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 44790625.73     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 16935951.29 4663.87   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:5_SUPPHEATCOIL

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 3162302.15 2917.89 02-JAN-07:02 0.00 0.00 0.00 0.00 0.00
February 2726041.46 2917.89 01-FEB-07:01 0.00 0.00 0.00 0.00 0.00
March 842126.28 2917.89 01-MAR-07:02 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 219037.03 2190.37 28-NOV-07:02 0.00 0.00 0.00 0.00 0.00
December 3644019.50 2917.89 04-DEC-07:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 10593526.41     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 3644019.50 2917.89   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:1 HP COOLING COIL

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 49321191.51 47620808.49 1137.25 12-JAN-15:52 1051.44 0.00
February 0.00 0.00 0.136109E+09 0.134744E+09 1519.91 23-FEB-14:58 1519.91 0.00
March 0.00 0.00 0.483146E+09 0.482967E+09 1978.99 16-MAR-15:00 1978.99 0.00
April 0.00 0.00 0.149387E+10 0.145656E+10 5825.21 19-APR-07:02 5162.40 0.00
May 0.00 0.00 0.297407E+10 0.282188E+10 6066.17 25-MAY-07:02 4432.01 0.00
June 0.00 0.00 0.402449E+10 0.377086E+10 6144.31 20-JUN-06:01 4923.11 0.00
July 0.00 0.00 0.423598E+10 0.348281E+10 6472.62 21-JUL-06:03 3512.40 0.00
August 0.00 0.00 0.450131E+10 0.379710E+10 6343.61 03-AUG-06:02 4238.56 0.00
September 0.00 0.00 0.361408E+10 0.311643E+10 6266.43 14-SEP-06:03 4144.22 0.00
October 0.00 0.00 0.254395E+10 0.223448E+10 6176.36 04-OCT-06:03 4338.14 0.00
November 0.00 0.00 0.948358E+09 0.887111E+09 5764.76 10-NOV-08:62 5377.67 0.00
December 0.00 0.00 57108164.42 55810025.47 833.77 15-DEC-16:05 833.77 0.00
                 
Annual Sum or Average 0.00 0.00 0.250618E+11 0.222884E+11       0.00
Minimum of Months 0.00 0.00 49321191.51 47620808.49 833.77   833.77 0.00
Maximum of Months 0.00 0.00 0.450131E+10 0.379710E+10 6472.62   5377.67 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:2 HP COOLING COIL

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.400219E+09 0.400219E+09 3007.16 12-JAN-14:55 3007.16 0.00
February 0.00 0.00 0.355015E+09 0.355015E+09 2916.67 22-FEB-14:00 2916.67 0.00
March 0.00 0.00 0.450708E+09 0.450708E+09 2612.19 16-MAR-14:40 2612.19 0.00
April 0.00 0.00 0.981182E+09 0.978727E+09 3752.82 21-APR-14:25 3752.82 0.00
May 0.00 0.00 0.212742E+10 0.205690E+10 6544.35 23-MAY-07:02 5655.28 0.00
June 0.00 0.00 0.340861E+10 0.327351E+10 6685.54 20-JUN-06:01 5521.82 0.00
July 0.00 0.00 0.387349E+10 0.329893E+10 7195.99 21-JUL-07:02 3534.50 0.00
August 0.00 0.00 0.415824E+10 0.366682E+10 6961.09 03-AUG-06:02 4793.79 0.00
September 0.00 0.00 0.374256E+10 0.340723E+10 6919.10 14-SEP-07:02 4355.17 0.00
October 0.00 0.00 0.300589E+10 0.282203E+10 6773.09 04-OCT-07:02 4853.58 0.00
November 0.00 0.00 0.153754E+10 0.151650E+10 6229.46 10-NOV-08:62 6229.46 0.00
December 0.00 0.00 0.340687E+09 0.340687E+09 2322.54 07-DEC-14:35 2322.54 0.00
                 
Annual Sum or Average 0.00 0.00 0.243816E+11 0.225673E+11       0.00
Minimum of Months 0.00 0.00 0.340687E+09 0.340687E+09 2322.54   2322.54 0.00
Maximum of Months 0.00 0.00 0.415824E+10 0.366682E+10 7195.99   6229.46 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:3 HP COOLING COIL

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 5353002.03 5353002.03 319.08 12-JAN-15:54 319.08 0.00
February 0.00 0.00 37984472.72 37984472.72 731.50 22-FEB-15:55 731.50 0.00
March 0.00 0.00 0.187906E+09 0.187906E+09 962.06 16-MAR-13:00 962.06 0.00
April 0.00 0.00 0.837221E+09 0.835284E+09 4534.16 28-APR-07:02 4534.16 0.00
May 0.00 0.00 0.178379E+10 0.174529E+10 4840.82 25-MAY-07:02 3895.11 0.00
June 0.00 0.00 0.257134E+10 0.249844E+10 4877.02 20-JUN-06:01 4212.61 0.00
July 0.00 0.00 0.275246E+10 0.246784E+10 5113.10 20-JUL-06:02 3332.38 0.00
August 0.00 0.00 0.290073E+10 0.265801E+10 5050.69 03-AUG-06:02 3761.12 0.00
September 0.00 0.00 0.231388E+10 0.215173E+10 4959.48 22-SEP-06:02 3917.48 0.00
October 0.00 0.00 0.140679E+10 0.132484E+10 4916.17 04-OCT-07:02 3687.37 0.00
November 0.00 0.00 0.438499E+09 0.430704E+09 4585.06 10-NOV-08:62 4585.06 0.00
December 0.00 0.00 3402887.99 3402887.99 281.47 01-DEC-13:10 281.47 0.00
                 
Annual Sum or Average 0.00 0.00 0.152394E+11 0.143468E+11       0.00
Minimum of Months 0.00 0.00 3402887.99 3402887.99 281.47   281.47 0.00
Maximum of Months 0.00 0.00 0.290073E+10 0.265801E+10 5113.10   4585.06 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:4 HP COOLING COIL

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 0.00 0.00
February 0.00 0.00 4154121.95 4154121.95 366.86 23-FEB-14:55 366.86 0.00
March 0.00 0.00 60000766.28 60000766.28 1063.31 16-MAR-15:33 1063.31 0.00
April 0.00 0.00 0.767200E+09 0.763190E+09 5228.48 20-APR-07:02 5228.48 0.00
May 0.00 0.00 0.208817E+10 0.202175E+10 6530.10 25-MAY-07:02 5047.04 0.00
June 0.00 0.00 0.329344E+10 0.316494E+10 6587.60 20-JUN-06:01 5587.04 0.00
July 0.00 0.00 0.370795E+10 0.322318E+10 6939.30 21-JUL-07:02 4045.17 0.00
August 0.00 0.00 0.379818E+10 0.337919E+10 6829.46 03-AUG-06:02 4906.14 0.00
September 0.00 0.00 0.286528E+10 0.258736E+10 6716.69 14-SEP-07:02 4711.35 0.00
October 0.00 0.00 0.162613E+10 0.148556E+10 6661.04 04-OCT-07:02 4898.53 0.00
November 0.00 0.00 0.315456E+09 0.301348E+09 3702.14 10-NOV-08:62 3702.14 0.00
December 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 0.00 0.00
                 
Annual Sum or Average 0.00 0.00 0.185260E+11 0.169907E+11       0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00   0.00 0.00
Maximum of Months 0.00 0.00 0.379818E+10 0.337919E+10 6939.30   5587.04 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:5 HP COOLING COIL

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 33325627.04 33325627.04 930.16 12-JAN-16:06 930.16 0.00
February 0.00 0.00 50432119.36 50432119.36 1254.87 21-FEB-16:53 1254.87 0.00
March 0.00 0.00 0.171988E+09 0.171988E+09 1642.59 16-MAR-15:53 1642.59 0.00
April 0.00 0.00 0.753062E+09 0.749233E+09 5452.99 20-APR-07:02 5452.99 0.00
May 0.00 0.00 0.167280E+10 0.162852E+10 5849.41 25-MAY-07:02 4661.68 0.00
June 0.00 0.00 0.247442E+10 0.238959E+10 5902.15 20-JUN-06:01 5127.56 0.00
July 0.00 0.00 0.273328E+10 0.242416E+10 6174.76 21-JUL-07:02 3761.73 0.00
August 0.00 0.00 0.287789E+10 0.261015E+10 6092.49 03-AUG-06:02 4590.27 0.00
September 0.00 0.00 0.231030E+10 0.212762E+10 6020.39 14-SEP-06:03 4688.33 0.00
October 0.00 0.00 0.147264E+10 0.137501E+10 5938.76 04-OCT-07:02 4510.04 0.00
November 0.00 0.00 0.496015E+09 0.483921E+09 4896.05 10-NOV-08:62 4896.05 0.00
December 0.00 0.00 32403259.67 32403259.67 780.04 15-DEC-16:27 780.04 0.00
                 
Annual Sum or Average 0.00 0.00 0.150786E+11 0.140764E+11       0.00
Minimum of Months 0.00 0.00 32403259.67 32403259.67 780.04   780.04 0.00
Maximum of Months 0.00 0.00 0.287789E+10 0.261015E+10 6174.76   5452.99 0.00



Table of Contents

Report: PlantLoopDemandReportMonthly

For: SWHSYS1

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

PLANT SUPPLY SIDE COOLING DEMAND RATE [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} PLANT SUPPLY SIDE HEATING DEMAND RATE [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP}
January 0.00 0.00 01-JAN-00:10 230.15 575.54 30-JAN-12:17
February 0.00 0.00 01-FEB-00:10 0.00 0.00 01-FEB-00:10
March 0.00 0.00 01-MAR-00:10 0.00 0.00 01-MAR-00:10
April 0.00 0.00 01-APR-00:10 0.00 0.00 01-APR-00:10
May 0.00 0.00 01-MAY-00:10 0.00 0.00 01-MAY-00:10
June 0.00 0.00 01-JUN-00:10 0.00 0.00 01-JUN-00:10
July 0.00 0.00 01-JUL-00:10 0.00 0.00 01-JUL-00:10
August 0.00 0.00 01-AUG-00:10 0.00 0.00 01-AUG-00:10
September 0.00 0.00 01-SEP-00:10 0.00 0.00 01-SEP-00:10
October 0.00 0.00 01-OCT-00:10 0.00 0.00 01-OCT-00:10
November 0.00 0.00 01-NOV-00:10 0.00 0.00 01-NOV-00:10
December 0.00 0.00 01-DEC-00:10 0.00 0.00 01-DEC-00:10
             
Annual Sum or Average 0.00     19.55    
Minimum of Months 0.00 0.00   0.00 0.00  
Maximum of Months 0.00 0.00   230.15 575.54  



Table of Contents

Report: FanReportMonthly

For: PSZ-AC:1 FAN

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.371687E+09 0.39 378.19 02-JAN-06:05 1.06
February 0.336288E+09 0.39 378.19 01-FEB-06:05 1.06
March 0.407086E+09 0.42 378.19 01-MAR-06:05 1.05
April 0.353988E+09 0.38 378.19 03-APR-05:05 1.06
May 0.389387E+09 0.40 378.19 01-MAY-05:10 1.05
June 0.389387E+09 0.42 378.19 01-JUN-05:10 1.05
July 0.353988E+09 0.37 378.19 03-JUL-05:02 1.05
August 0.407086E+09 0.42 378.19 01-AUG-05:05 1.04
September 0.353988E+09 0.38 378.19 01-SEP-05:10 1.04
October 0.371687E+09 0.39 378.19 02-OCT-05:03 1.05
November 0.371687E+09 0.40 378.19 01-NOV-05:10 1.05
December 0.353988E+09 0.37 378.19 01-DEC-06:05 1.05
           
Annual Sum or Average 0.446025E+10 0.39      
Minimum of Months 0.336288E+09 0.37 378.19   1.04
Maximum of Months 0.407086E+09 0.42 378.19   1.06



Table of Contents

Report: FanReportMonthly

For: PSZ-AC:2 FAN

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.427882E+09 0.39 435.37 02-JAN-06:05 1.06
February 0.387131E+09 0.39 435.37 01-FEB-06:05 1.06
March 0.468633E+09 0.43 435.37 01-MAR-06:05 1.06
April 0.407507E+09 0.38 435.37 03-APR-05:05 1.06
May 0.448257E+09 0.41 435.37 01-MAY-05:10 1.06
June 0.448257E+09 0.42 435.37 01-JUN-05:10 1.06
July 0.407507E+09 0.37 435.37 03-JUL-05:02 1.05
August 0.469981E+09 0.43 435.37 01-AUG-05:05 1.05
September 0.411577E+09 0.40 435.37 01-SEP-05:10 1.05
October 0.431132E+09 0.40 435.37 01-OCT-14:13 1.06
November 0.427882E+09 0.40 435.37 01-NOV-05:10 1.06
December 0.407507E+09 0.37 435.37 01-DEC-06:05 1.06
           
Annual Sum or Average 0.514325E+10 0.40      
Minimum of Months 0.387131E+09 0.37 435.37   1.05
Maximum of Months 0.469981E+09 0.43 435.37   1.06



Table of Contents

Report: FanReportMonthly

For: PSZ-AC:3 FAN

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.312186E+09 0.39 317.65 02-JAN-06:05 1.06
February 0.282454E+09 0.39 317.65 01-FEB-06:05 1.06
March 0.341918E+09 0.43 317.65 01-MAR-06:05 1.06
April 0.297320E+09 0.38 317.65 03-APR-05:05 1.06
May 0.327052E+09 0.41 317.65 01-MAY-05:10 1.06
June 0.328329E+09 0.43 317.65 01-JUN-05:10 1.06
July 0.300988E+09 0.40 317.65 03-JUL-05:02 1.05
August 0.346745E+09 0.47 317.65 01-AUG-05:05 1.05
September 0.299775E+09 0.41 317.65 01-SEP-05:10 1.05
October 0.312186E+09 0.39 317.65 02-OCT-05:03 1.05
November 0.312186E+09 0.40 317.65 01-NOV-05:10 1.06
December 0.297320E+09 0.37 317.65 01-DEC-06:05 1.06
           
Annual Sum or Average 0.375846E+10 0.40      
Minimum of Months 0.282454E+09 0.37 317.65   1.05
Maximum of Months 0.346745E+09 0.47 317.65   1.06



Table of Contents

Report: FanReportMonthly

For: PSZ-AC:4 FAN

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.422312E+09 0.39 429.70 02-JAN-06:05 1.06
February 0.382091E+09 0.39 429.70 01-FEB-06:05 1.06
March 0.462532E+09 0.43 429.70 01-MAR-06:05 1.06
April 0.402201E+09 0.38 429.70 03-APR-05:05 1.06
May 0.442422E+09 0.41 429.70 01-MAY-05:10 1.06
June 0.442422E+09 0.42 429.70 01-JUN-05:10 1.05
July 0.402405E+09 0.37 429.70 03-JUL-05:02 1.05
August 0.463451E+09 0.43 429.70 01-AUG-05:05 1.05
September 0.402201E+09 0.38 429.70 01-SEP-05:10 1.05
October 0.422312E+09 0.39 429.70 02-OCT-05:03 1.05
November 0.422312E+09 0.40 429.70 01-NOV-05:10 1.06
December 0.402201E+09 0.37 429.70 01-DEC-06:05 1.06
           
Annual Sum or Average 0.506886E+10 0.40      
Minimum of Months 0.382091E+09 0.37 429.70   1.05
Maximum of Months 0.463451E+09 0.43 429.70   1.06



Table of Contents

Report: FanReportMonthly

For: PSZ-AC:5 FAN

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.377460E+09 0.39 384.07 02-JAN-06:05 1.06
February 0.341512E+09 0.39 384.07 01-FEB-06:05 1.06
March 0.413409E+09 0.43 384.07 01-MAR-06:05 1.06
April 0.359486E+09 0.38 384.07 03-APR-05:05 1.06
May 0.396411E+09 0.41 384.07 01-MAY-05:10 1.06
June 0.400365E+09 0.45 384.07 01-JUN-05:10 1.05
July 0.367927E+09 0.42 384.07 02-JUL-16:33 1.05
August 0.422151E+09 0.47 384.07 01-AUG-05:05 1.05
September 0.363418E+09 0.41 384.07 01-SEP-05:10 1.05
October 0.377578E+09 0.39 384.07 02-OCT-05:03 1.05
November 0.377460E+09 0.40 384.07 01-NOV-05:10 1.06
December 0.359486E+09 0.37 384.07 01-DEC-06:05 1.06
           
Annual Sum or Average 0.455666E+10 0.41      
Minimum of Months 0.341512E+09 0.37 384.07   1.05
Maximum of Months 0.422151E+09 0.47 384.07   1.06



Table of Contents

Report: PumpReportMonthly

For: SWHSYS1 PUMP

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

PUMP ELECTRICITY ENERGY [J] PUMP FLUID HEAT GAIN ENERGY [J] PUMP ELECTRICITY RATE {Maximum} [W] PUMP ELECTRICITY RATE {TIMESTAMP} PUMP SHAFT POWER {AT MAX/MIN} [W] PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s]
January 0.02 0.01 0.00 02-JAN-07:02 0.00 0.00 43.22 0.00
February 0.00 0.00 0.00 01-FEB-00:10 0.00 0.00 14.91 0.00
March 0.00 0.00 0.00 01-MAR-00:10 0.00 0.00 14.91 0.00
April 0.00 0.00 0.00 01-APR-00:10 0.00 0.00 14.91 0.00
May 0.00 0.00 0.00 01-MAY-00:10 0.00 0.00 14.91 0.00
June 0.00 0.00 0.00 01-JUN-00:10 0.00 0.00 14.91 0.00
July 0.00 0.00 0.00 01-JUL-00:10 0.00 0.00 14.91 0.00
August 0.00 0.00 0.00 01-AUG-00:10 0.00 0.00 14.91 0.00
September 0.00 0.00 0.00 01-SEP-00:10 0.00 0.00 14.91 0.00
October 0.00 0.00 0.00 01-OCT-00:10 0.00 0.00 14.91 0.00
November 0.00 0.00 0.00 01-NOV-00:10 0.00 0.00 14.91 0.00
December 0.00 0.00 0.00 01-DEC-00:10 0.00 0.00 14.91 0.00
                 
Annual Sum or Average 0.02 0.01            
Minimum of Months 0.00 0.00 0.00   0.00 0.00 14.91 0.00
Maximum of Months 0.02 0.01 0.00   0.00 0.00 43.22 0.00



Table of Contents

Report: CondLoopDemandReportMonthly

For: SWHSYS1

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

PLANT SUPPLY SIDE COOLING DEMAND RATE [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] PLANT SUPPLY SIDE HEATING DEMAND RATE [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP}
January 0.00 0.00 01-JAN-00:10 48.89 48.89 230.15 575.54 30-JAN-12:17
February 0.00 0.00 01-FEB-00:10 14.91 14.91 0.00 0.00 01-FEB-00:10
March 0.00 0.00 01-MAR-00:10 14.91 14.91 0.00 0.00 01-MAR-00:10
April 0.00 0.00 01-APR-00:10 14.91 14.91 0.00 0.00 01-APR-00:10
May 0.00 0.00 01-MAY-00:10 14.91 14.91 0.00 0.00 01-MAY-00:10
June 0.00 0.00 01-JUN-00:10 14.91 14.91 0.00 0.00 01-JUN-00:10
July 0.00 0.00 01-JUL-00:10 14.91 14.91 0.00 0.00 01-JUL-00:10
August 0.00 0.00 01-AUG-00:10 14.91 14.91 0.00 0.00 01-AUG-00:10
September 0.00 0.00 01-SEP-00:10 14.91 14.91 0.00 0.00 01-SEP-00:10
October 0.00 0.00 01-OCT-00:10 14.91 14.91 0.00 0.00 01-OCT-00:10
November 0.00 0.00 01-NOV-00:10 14.91 14.91 0.00 0.00 01-NOV-00:10
December 0.00 0.00 01-DEC-00:10 14.91 14.91 0.00 0.00 01-DEC-00:10
                 
Annual Sum or Average 0.00         19.55    
Minimum of Months 0.00 0.00   14.91 14.91 0.00 0.00  
Maximum of Months 0.00 0.00   48.89 48.89 230.15 575.54  



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: ATTIC

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00 0.00
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: PSZ-AC:1

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.396578E+09 0.00 0.00
February 0.00 0.00 0.00 0.374209E+09 0.00 0.00
March 0.00 0.00 0.00 0.519750E+09 0.00 0.00
April 0.00 0.00 0.00 0.694138E+09 0.00 0.00
May 0.00 0.00 0.00 0.106600E+10 0.00 0.00
June 0.00 0.00 0.00 0.134314E+10 0.00 0.00
July 0.00 0.00 0.00 0.130871E+10 0.00 0.00
August 0.00 0.00 0.00 0.140674E+10 0.00 0.00
September 0.00 0.00 0.00 0.115148E+10 0.00 0.00
October 0.00 0.00 0.00 0.919934E+09 0.00 0.00
November 0.00 0.00 0.00 0.582317E+09 0.00 0.00
December 0.00 0.00 0.00 0.395233E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.101582E+11 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.374209E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.140674E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: PSZ-AC:2

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.625048E+09 0.00 0.00
February 0.00 0.00 0.00 0.547277E+09 0.00 0.00
March 0.00 0.00 0.00 0.647518E+09 0.00 0.00
April 0.00 0.00 0.00 0.647738E+09 0.00 0.00
May 0.00 0.00 0.00 0.958095E+09 0.00 0.00
June 0.00 0.00 0.00 0.129810E+10 0.00 0.00
July 0.00 0.00 0.00 0.131304E+10 0.00 0.00
August 0.00 0.00 0.00 0.142629E+10 0.00 0.00
September 0.00 0.00 0.00 0.125501E+10 0.00 0.00
October 0.00 0.00 0.00 0.107544E+10 0.00 0.00
November 0.00 0.00 0.00 0.775247E+09 0.00 0.00
December 0.00 0.00 0.00 0.623430E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.111922E+11 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.547277E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.142629E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: PSZ-AC:3

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.372612E+09 0.00 0.00
February 0.00 0.00 0.00 0.325353E+09 0.00 0.00
March 0.00 0.00 0.00 0.406040E+09 0.00 0.00
April 0.00 0.00 0.00 0.492547E+09 0.00 0.00
May 0.00 0.00 0.00 0.745680E+09 0.00 0.00
June 0.00 0.00 0.00 0.962447E+09 0.00 0.00
July 0.00 0.00 0.00 0.949036E+09 0.00 0.00
August 0.00 0.00 0.00 0.101869E+10 0.00 0.00
September 0.00 0.00 0.00 0.828557E+09 0.00 0.00
October 0.00 0.00 0.00 0.625594E+09 0.00 0.00
November 0.00 0.00 0.00 0.417142E+09 0.00 0.00
December 0.00 0.00 0.00 0.378212E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.752191E+10 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.325353E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.101869E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: PSZ-AC:4

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.614792E+09 0.00 0.00
February 0.00 0.00 0.00 0.516707E+09 0.00 0.00
March 0.00 0.00 0.00 0.550865E+09 0.00 0.00
April 0.00 0.00 0.00 0.586163E+09 0.00 0.00
May 0.00 0.00 0.00 0.941155E+09 0.00 0.00
June 0.00 0.00 0.00 0.126086E+10 0.00 0.00
July 0.00 0.00 0.00 0.127228E+10 0.00 0.00
August 0.00 0.00 0.00 0.134315E+10 0.00 0.00
September 0.00 0.00 0.00 0.106305E+10 0.00 0.00
October 0.00 0.00 0.00 0.788590E+09 0.00 0.00
November 0.00 0.00 0.00 0.512921E+09 0.00 0.00
December 0.00 0.00 0.00 0.622970E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.100735E+11 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.512921E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.134315E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: PSZ-AC:5

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.456218E+09 0.00 0.00
February 0.00 0.00 0.00 0.405259E+09 0.00 0.00
March 0.00 0.00 0.00 0.479076E+09 0.00 0.00
April 0.00 0.00 0.00 0.538971E+09 0.00 0.00
May 0.00 0.00 0.00 0.801363E+09 0.00 0.00
June 0.00 0.00 0.00 0.103269E+10 0.00 0.00
July 0.00 0.00 0.00 0.103340E+10 0.00 0.00
August 0.00 0.00 0.00 0.111038E+10 0.00 0.00
September 0.00 0.00 0.00 0.907231E+09 0.00 0.00
October 0.00 0.00 0.00 0.710610E+09 0.00 0.00
November 0.00 0.00 0.00 0.495191E+09 0.00 0.00
December 0.00 0.00 0.00 0.460641E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.843102E+10 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.405259E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.111038E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: PSZ-AC:1

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.371687E+09 49321191.51 16129826.49 0.00 0.00 0.00 0.00 0.00
February 0.336288E+09 0.136109E+09 5130129.35 0.00 0.00 0.00 0.00 0.00
March 0.407086E+09 0.483146E+09 1140695.02 0.00 0.00 0.00 0.00 0.00
April 0.353988E+09 0.149387E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.389387E+09 0.297407E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.389387E+09 0.402449E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.353988E+09 0.423598E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.407086E+09 0.450131E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.353988E+09 0.361408E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.371687E+09 0.254395E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 0.371687E+09 0.948358E+09 0.00 0.00 0.00 0.00 0.00 0.00
December 0.353988E+09 57108164.42 36319251.85 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.446025E+10 0.250618E+11 58719902.71 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.336288E+09 49321191.51 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.407086E+09 0.450131E+10 36319251.85 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: PSZ-AC:2

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.427882E+09 0.400219E+09 0.289235E+09 0.00 0.00 0.00 0.00 0.00
February 0.387131E+09 0.355015E+09 0.219619E+09 0.00 0.00 0.00 0.00 0.00
March 0.468633E+09 0.450708E+09 0.215165E+09 0.00 0.00 0.00 0.00 0.00
April 0.407507E+09 0.981182E+09 22223470.42 0.00 0.00 0.00 0.00 0.00
May 0.448257E+09 0.212742E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.448257E+09 0.340861E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.407507E+09 0.387349E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.469981E+09 0.415824E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.411577E+09 0.374256E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.431132E+09 0.300589E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 0.427882E+09 0.153754E+10 54445488.04 0.00 0.00 0.00 0.00 0.00
December 0.407507E+09 0.340687E+09 0.329413E+09 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.514325E+10 0.243816E+11 0.113010E+10 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.387131E+09 0.340687E+09 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.469981E+09 0.415824E+10 0.329413E+09 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: PSZ-AC:3

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.312186E+09 5353002.03 0.140769E+09 0.00 0.00 0.00 0.00 0.00
February 0.282454E+09 37984472.72 75037464.21 0.00 0.00 0.00 0.00 0.00
March 0.341918E+09 0.187906E+09 47959092.90 0.00 0.00 0.00 0.00 0.00
April 0.297320E+09 0.837221E+09 0.00 0.00 0.00 0.00 0.00 0.00
May 0.327052E+09 0.178379E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.328329E+09 0.257134E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.300988E+09 0.275246E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.346745E+09 0.290073E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.299775E+09 0.231388E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.312186E+09 0.140679E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 0.312186E+09 0.438499E+09 10414602.11 0.00 0.00 0.00 0.00 0.00
December 0.297320E+09 3402887.99 0.156815E+09 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.375846E+10 0.152394E+11 0.430995E+09 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.282454E+09 3402887.99 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.346745E+09 0.290073E+10 0.156815E+09 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: PSZ-AC:4

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.422312E+09 0.00 0.521577E+09 0.00 0.00 0.00 0.00 0.00
February 0.382091E+09 4154121.95 0.354269E+09 0.00 0.00 0.00 0.00 0.00
March 0.462532E+09 60000766.28 0.202340E+09 0.00 0.00 0.00 0.00 0.00
April 0.402201E+09 0.767200E+09 1013396.25 0.00 0.00 0.00 0.00 0.00
May 0.442422E+09 0.208817E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.442422E+09 0.329344E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.402405E+09 0.370795E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.463451E+09 0.379818E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.402201E+09 0.286528E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.422312E+09 0.162613E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 0.422312E+09 0.315456E+09 44790059.43 0.00 0.00 0.00 0.00 0.00
December 0.402201E+09 0.00 0.521812E+09 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.506886E+10 0.185260E+11 0.164580E+10 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.382091E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.463451E+09 0.379818E+10 0.521812E+09 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: PSZ-AC:5

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.377460E+09 33325627.04 0.171429E+09 0.00 0.00 0.00 0.00 0.00
February 0.341512E+09 50432119.36 0.122101E+09 0.00 0.00 0.00 0.00 0.00
March 0.413409E+09 0.171988E+09 60631976.59 0.00 0.00 0.00 0.00 0.00
April 0.359486E+09 0.753062E+09 0.00 0.00 0.00 0.00 0.00 0.00
May 0.396411E+09 0.167280E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.400365E+09 0.247442E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.367927E+09 0.273328E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.422151E+09 0.287789E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.363418E+09 0.231030E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.377578E+09 0.147264E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 0.377460E+09 0.496015E+09 10316869.24 0.00 0.00 0.00 0.00 0.00
December 0.359486E+09 32403259.67 0.187040E+09 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.455666E+10 0.150786E+11 0.551518E+09 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.341512E+09 32403259.67 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.422151E+09 0.287789E+10 0.187040E+09 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: PSZ-AC:1

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.371687E+09 0.00 0.00 13778770.63 11112512.23 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.336288E+09 0.00 0.00 7263903.54 30656854.97 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.407086E+09 0.00 0.00 4219555.45 0.108445E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.353988E+09 0.00 0.00 300000.00 0.339850E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.389387E+09 0.00 0.00 0.00 0.676616E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.389387E+09 0.00 0.00 0.00 0.953749E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.353988E+09 0.00 0.00 0.00 0.954724E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.407086E+09 0.00 0.00 0.00 0.999654E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.353988E+09 0.00 0.00 0.00 0.797488E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.371687E+09 0.00 0.00 0.00 0.548247E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.371687E+09 0.00 0.00 3510000.00 0.207120E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.353988E+09 0.00 0.00 28317502.02 12927440.29 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.446025E+10 0.00 0.00 57389731.65 0.564059E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.336288E+09 0.00 0.00 0.00 11112512.23 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.407086E+09 0.00 0.00 28317502.02 0.999654E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: PSZ-AC:2

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.427882E+09 0.00 0.00 0.109251E+09 87914986.76 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.387131E+09 0.00 0.00 81912110.13 78233239.63 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.468633E+09 0.00 0.00 77935011.88 0.100951E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.407507E+09 0.00 0.00 7978480.02 0.232253E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.448257E+09 0.00 0.00 0.00 0.509838E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.448257E+09 0.00 0.00 0.00 0.849841E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.407507E+09 0.00 0.00 0.00 0.905531E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.469981E+09 0.00 0.00 0.00 0.956304E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.411577E+09 0.00 0.00 0.00 0.843429E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.431132E+09 0.00 0.00 0.00 0.644308E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.427882E+09 0.00 0.00 23506462.84 0.323859E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.407507E+09 0.00 0.00 0.140749E+09 75174553.32 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.514325E+10 0.00 0.00 0.441332E+09 0.560764E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.387131E+09 0.00 0.00 0.00 75174553.32 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.469981E+09 0.00 0.00 0.140749E+09 0.956304E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: PSZ-AC:3

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.312186E+09 0.00 0.00 59203975.23 1221747.69 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.282454E+09 0.00 0.00 34241077.09 8657805.04 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.341918E+09 0.00 0.00 21288602.43 42833995.68 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.297320E+09 0.00 0.00 300000.00 0.194927E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.327052E+09 0.00 0.00 0.00 0.418629E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.328329E+09 0.00 0.00 0.00 0.634118E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.300988E+09 0.00 0.00 0.00 0.648049E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.346745E+09 0.00 0.00 0.00 0.671943E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.299775E+09 0.00 0.00 0.00 0.528783E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.312186E+09 0.00 0.00 0.00 0.313409E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.312186E+09 0.00 0.00 7420112.72 97535747.25 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.297320E+09 0.00 0.00 80114914.40 777351.94 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.375846E+10 0.00 0.00 0.202569E+09 0.356088E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.282454E+09 0.00 0.00 0.00 777351.94 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.346745E+09 0.00 0.00 80114914.40 0.671943E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: PSZ-AC:4

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.422312E+09 0.00 0.00 0.192480E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.382091E+09 0.00 0.00 0.133659E+09 956812.37 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.462532E+09 0.00 0.00 74432850.58 13900583.33 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.402201E+09 0.00 0.00 627201.25 0.183334E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.442422E+09 0.00 0.00 0.00 0.498733E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.442422E+09 0.00 0.00 0.00 0.818436E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.402405E+09 0.00 0.00 0.00 0.869876E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.463451E+09 0.00 0.00 0.00 0.879697E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.402201E+09 0.00 0.00 0.00 0.660846E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.422312E+09 0.00 0.00 0.00 0.366278E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.422312E+09 0.00 0.00 19659309.42 70950298.58 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.402201E+09 0.00 0.00 0.220768E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.506886E+10 0.00 0.00 0.641626E+09 0.436301E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.382091E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.463451E+09 0.00 0.00 0.220768E+09 0.879697E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: PSZ-AC:5

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.377460E+09 0.00 0.00 71206276.87 7551193.63 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.341512E+09 0.00 0.00 52263616.88 11483707.53 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.413409E+09 0.00 0.00 26293259.15 39373778.88 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.359486E+09 0.00 0.00 300000.00 0.179185E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.396411E+09 0.00 0.00 0.00 0.404952E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.400365E+09 0.00 0.00 0.00 0.632321E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.367927E+09 0.00 0.00 0.00 0.665469E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.422151E+09 0.00 0.00 0.00 0.688228E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.363418E+09 0.00 0.00 0.00 0.543814E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.377578E+09 0.00 0.00 0.00 0.333032E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.377460E+09 0.00 0.00 7430992.24 0.110300E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.359486E+09 0.00 0.00 93813102.59 7342287.74 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.455666E+10 0.00 0.00 0.251307E+09 0.362305E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.341512E+09 0.00 0.00 0.00 7342287.74 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.422151E+09 0.00 0.00 93813102.59 0.688228E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.127232E+10 0.00 0.00 342768.24 0.00 3994440.31 0.148581E+09 0.00 0.19
February 0.933212E+09 0.00 0.00 888392.27 0.00 1769636.94 0.294486E+09 0.00 0.19
March 0.790064E+09 0.00 0.00 2331503.45 0.00 652754.00 0.531857E+09 0.00 0.21
April 0.251939E+09 80875.61 0.00 7477175.05 0.00 0.00 0.524845E+09 0.00 0.19
May 0.148646E+09 40265512.86 0.00 11448778.06 474982.67 0.00 0.320853E+09 0.00 0.20
June 54150641.79 92321439.87 0.00 9393621.30 5683830.54 0.00 86455492.69 0.00 0.21
July 7878808.94 0.422394E+09 0.00 1399043.95 30253826.41 0.00 16736709.88 0.00 0.18
August 35898895.74 0.266924E+09 0.00 4374632.91 12294986.84 0.00 41034061.86 0.00 0.21
September 63806417.57 0.165186E+09 0.00 7585064.18 4701077.48 0.00 0.123344E+09 0.00 0.19
October 0.190880E+09 47311126.84 0.00 9638278.00 2056965.58 0.00 0.452149E+09 0.00 0.19
November 0.581957E+09 0.00 0.00 5217778.13 0.00 0.00 0.629065E+09 0.00 0.20
December 0.124269E+10 0.00 0.00 458116.07 0.00 8141586.84 0.216689E+09 0.00 0.18
                   
Annual Sum or Average 0.557345E+10 0.103448E+10 0.00 60555151.60 55465669.52 14558418.08 0.338610E+10 0.00 0.19
Minimum of Months 7878808.94 0.00 0.00 342768.24 0.00 0.00 16736709.88 0.00 0.18
Maximum of Months 0.127232E+10 0.422394E+09 0.00 11448778.06 30253826.41 8141586.84 0.629065E+09 0.00 0.21



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.418404E+09 0.00 0.00 1918206.05 0.00 0.118440E+09 0.218121E+09 0.00 0.19
February 0.360838E+09 0.00 0.00 1729919.53 0.00 86260738.96 0.162749E+09 0.00 0.19
March 0.346782E+09 0.00 0.00 1460923.88 0.00 96379740.59 0.142715E+09 0.00 0.21
April 0.164246E+09 14626149.99 0.00 2565753.00 933004.71 10674581.84 0.109691E+09 0.00 0.19
May 66813666.61 88346319.20 0.00 3249724.97 6559973.30 0.00 64685701.15 0.00 0.20
June 32325920.49 0.221117E+09 0.00 1719646.40 21910294.27 0.00 7795666.11 0.00 0.21
July 8248270.19 0.393147E+09 0.00 483167.22 30754077.53 0.00 3027229.59 0.00 0.18
August 24336575.08 0.289597E+09 0.00 1480452.99 18075572.08 0.00 9048550.63 0.00 0.21
September 44725808.97 0.186516E+09 0.00 3731546.71 8189449.85 0.00 31663583.47 0.00 0.19
October 0.117148E+09 61327369.57 0.00 9469283.15 1925032.09 0.00 0.187367E+09 0.00 0.19
November 0.292878E+09 0.00 0.00 7552630.09 0.00 28407241.58 0.264508E+09 0.00 0.20
December 0.413817E+09 0.00 0.00 1744383.58 0.00 0.138444E+09 0.238605E+09 0.00 0.18
                   
Annual Sum or Average 0.229056E+10 0.125468E+10 0.00 37105637.57 88347403.83 0.478606E+09 0.143998E+10 0.00 0.19
Minimum of Months 8248270.19 0.00 0.00 483167.22 0.00 0.00 3027229.59 0.00 0.18
Maximum of Months 0.418404E+09 0.393147E+09 0.00 9469283.15 30754077.53 0.138444E+09 0.264508E+09 0.00 0.21



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.333798E+09 0.00 0.00 12943.40 0.00 99281706.39 4343015.72 0.00 0.19
February 0.283731E+09 0.00 0.00 120954.72 0.00 47378546.16 32427086.63 0.00 0.19
March 0.239574E+09 0.00 0.00 636271.50 0.00 32449709.21 99569646.50 0.00 0.21
April 78657733.64 8409829.45 0.00 3389400.07 152145.98 0.00 0.110026E+09 0.00 0.19
May 37687878.35 59666770.05 0.00 4445344.18 1989203.08 0.00 49958342.87 0.00 0.20
June 15444699.31 0.142788E+09 0.00 2083557.03 9986014.66 0.00 11460670.60 0.00 0.21
July 1773875.53 0.285564E+09 0.00 288526.94 20765948.25 0.00 2760153.27 0.00 0.18
August 8532361.29 0.214142E+09 0.00 928457.20 11532163.50 0.00 7603291.29 0.00 0.21
September 19552446.52 0.134316E+09 0.00 2862686.64 5507852.07 0.00 26406781.12 0.00 0.19
October 68187238.83 42910415.74 0.00 4555303.20 2031885.04 0.00 0.122257E+09 0.00 0.19
November 0.193646E+09 0.00 0.00 2101666.68 0.00 10334456.89 0.158020E+09 0.00 0.20
December 0.337784E+09 0.00 0.00 11972.07 0.00 0.114541E+09 9906097.20 0.00 0.18
                   
Annual Sum or Average 0.161837E+10 0.887797E+09 0.00 21437083.63 51965212.58 0.303985E+09 0.634738E+09 0.00 0.19
Minimum of Months 1773875.53 0.00 0.00 11972.07 0.00 0.00 2760153.27 0.00 0.18
Maximum of Months 0.337784E+09 0.285564E+09 0.00 4555303.20 20765948.25 0.114541E+09 0.158020E+09 0.00 0.21



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.376451E+09 0.00 0.00 0.00 0.00 0.368543E+09 0.00 0.00 0.19
February 0.368178E+09 0.00 0.00 5070.09 0.00 0.240078E+09 3989557.08 0.00 0.19
March 0.445421E+09 0.00 0.00 114099.44 0.00 0.149584E+09 34136199.09 0.00 0.21
April 0.200621E+09 6558855.76 0.00 2245269.55 107421.42 235236.87 0.152823E+09 0.00 0.19
May 76115736.78 67568494.31 0.00 4763981.47 2486097.54 0.00 94930187.92 0.00 0.20
June 28243759.68 0.190094E+09 0.00 2782140.18 14906084.08 0.00 20955415.94 0.00 0.21
July 3805820.34 0.436109E+09 0.00 418465.25 33983956.36 0.00 4632314.56 0.00 0.18
August 16353127.79 0.310410E+09 0.00 1460413.97 18718009.05 0.00 12842875.95 0.00 0.21
September 45428387.38 0.187038E+09 0.00 3275030.13 8958726.05 0.00 41096767.08 0.00 0.19
October 0.126058E+09 56423260.08 0.00 4361321.06 3276925.95 0.00 0.230712E+09 0.00 0.19
November 0.425820E+09 0.00 0.00 1205277.68 0.00 37649172.79 0.175144E+09 0.00 0.19
December 0.412618E+09 0.00 0.00 0.00 0.00 0.375763E+09 0.00 0.00 0.18
                   
Annual Sum or Average 0.252511E+10 0.125420E+10 0.00 20631068.81 82437220.45 0.117185E+10 0.771262E+09 0.00 0.19
Minimum of Months 3805820.34 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.18
Maximum of Months 0.445421E+09 0.436109E+09 0.00 4763981.47 33983956.36 0.375763E+09 0.230712E+09 0.00 0.21



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.295449E+09 0.00 0.00 142281.64 0.00 0.143268E+09 31903571.02 0.00 0.19
February 0.248048E+09 0.00 0.00 195195.87 0.00 0.102354E+09 34004061.18 0.00 0.19
March 0.279637E+09 0.00 0.00 468280.38 0.00 59434085.20 59350752.76 0.00 0.21
April 0.104546E+09 4125522.69 0.00 2346776.65 34427.72 0.00 0.111917E+09 0.00 0.19
May 45746781.86 44091272.48 0.00 3459532.27 978675.94 0.00 59090150.02 0.00 0.20
June 17738577.68 0.120840E+09 0.00 1814068.21 6028567.71 0.00 12240711.27 0.00 0.21
July 2186115.17 0.276634E+09 0.00 352302.67 17432717.07 0.00 1884692.66 0.00 0.19
August 9040634.82 0.199413E+09 0.00 926977.99 9429413.24 0.00 7615513.21 0.00 0.21
September 21417511.51 0.122364E+09 0.00 2639614.26 4136456.41 0.00 29994420.96 0.00 0.19
October 70896010.94 39103734.85 0.00 4200901.09 1844439.15 0.00 0.140734E+09 0.00 0.19
November 0.221967E+09 0.00 0.00 2042499.25 0.00 12566233.09 0.156857E+09 0.00 0.20
December 0.294298E+09 0.00 0.00 155398.23 0.00 0.163072E+09 36515536.70 0.00 0.18
                   
Annual Sum or Average 0.161097E+10 0.806572E+09 0.00 18743828.51 39884697.25 0.480695E+09 0.682107E+09 0.00 0.19
Minimum of Months 2186115.17 0.00 0.00 142281.64 0.00 0.00 1884692.66 0.00 0.18
Maximum of Months 0.295449E+09 0.276634E+09 0.00 4200901.09 17432717.07 0.163072E+09 0.156857E+09 0.00 0.21



Table of Contents

Report: HeatEmissionsReportMonthly

For: Environment

Timestamp: 2023-10-16 08:29:45

Custom Monthly Report

SITE TOTAL SURFACE HEAT EMISSION TO AIR [J] SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J]
January 0.632136E+11 0.202984E+10 0.00 0.101547E+11 42670099.32
February 0.706501E+11 0.221154E+10 0.00 0.842776E+10 0.368429E+09
March 0.113198E+12 0.320643E+10 0.00 0.871819E+10 0.139693E+10
April 0.130048E+12 0.348486E+10 0.00 0.578565E+10 0.594835E+10
May 0.144690E+12 0.360348E+10 0.00 0.357936E+10 0.131550E+11
June 0.144444E+12 0.362821E+10 0.00 0.455271E+09 0.196608E+11
July 0.137528E+12 0.340472E+10 0.00 -0.238225E+10 0.213468E+11
August 0.125183E+12 0.326665E+10 0.00 -306475016.5 0.224322E+11
September 0.110725E+12 0.273641E+10 0.00 0.156951E+10 0.182205E+11
October 0.918082E+11 0.237758E+10 0.00 0.542799E+10 0.122607E+11
November 0.672487E+11 0.208425E+10 0.00 0.103001E+11 0.454440E+10
December 0.521590E+11 0.165174E+10 0.00 0.117295E+11 0.112251E+09
           
Annual Sum or Average 0.125089E+13 0.336857E+11 0.00 0.634593E+11 0.119489E+12
Minimum of Months 0.521590E+11 0.165174E+10 0.00 -0.238225E+10 42670099.32
Maximum of Months 0.144690E+12 0.362821E+10 0.00 0.117295E+11 0.224322E+11